Loading...
Permit 7 CITY OF TIGARD 3 4 ) BUILDING PERMIT ii le C OMMUNITY DEVELOPMENT P ermit #: BUP2010 -00100 TIGARD 13125 SW Hall Blvd., Tigard OR 97223 503.718.2439 Date Issued: 05/20/2010 Parcel: 25101 DC04000 Jurisdiction: Tigard Site address: 7550 SW TECH CENTER DR 220 Project: Cochran Subdivision: Lot: 0 Project Description: Racking. 2/3/11, reprinted to correct suite number from 250 to 220. Contractor: ABOVE ALL INSTALLATIONS LLC Owner: WALTON CWOR SOUTHRIDGE 12 LLC 16200 SW PACIFIC HWY BY TTA/EPROPERTYTAX DEPT 325 SUITE H PO BOX 4900 TIGARD, OR 97224 SCOTTSDALE, AZ 85261 PHONE: 503 - 969 -2506 PHONE: FAX: FEES Specifics: Description Date Amount Type of Use: COM Permit Fee - Additions, Alterations, 05/13/2010 $164.96 Class of Work: ALT Demolition Dwelling Units: 0 12% State Surcharge - Building 05/13/2010 $19.80 Stories: 0 Height: 0 ft Plan Review 05/13/2010 $107.22 Bedrooms: 0 Bathrooms: 0 Plan Review - Fire Life Safety 05/13/2010 $65.98 Value: $5,800 Floor Areas: Total Area: 0 Accessory Struct: 0 Basement: 0 Carport 0 Covered Porch: 0 Deck: 0 Garage: 0 Mezzanine: 0 Total $357.96 Required' Required Items and Reports (Conditions) 1 Bolts in Concrete Fire Sprinkler: Parapet: Fire Alarm: Protected Corridors: Smoke Detectors: Manual Pull Stations: Accessible Parking: 0 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952 -001- 0 through ■ • R 952 - 001 -0090. You may obtain a copy of the rules or direct questions to OUNC by calling 503.232.1987 or 1.800.332.2344. Issued y: �� II' ... :.1. • Permittee Signat e: /� ' C..- awl Call 503.639.4175 by 7:00 a.m. for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. 1 t i . t t Rgik �:,'?e`'' BUILDING PERMIT CITY OF TIGARD ` :a n COMMUNITY DEVELOPMENT Permit#: BUP201000100 ;-VZ; Date Issued: 05/20/2010 4.1 GARD 13125 SW Hall Blvd., Tigard OR 97223 503.639.4171 , . ,, : :71 x Parcel: 2S101DC04000 Jurisdiction: Tigard Site address: 7550 SW TECH CENTER DR 250 Subdivision: Lot: 0 Project: Cochran Project Description: Racking Owner: FEES WALTON CWOR SOUTHRIDGE 12 LLC Description Date Amount BY TTA/EPROPERTYTAX DEPT 325, PO BOX Permit Fee - Additions, Alterations, 05/13/2010 $164.96 4900 Demolition PHONE: 12% State Surcharge - Building 05/13/2010 $19.80 Plan Review 05/13/2010 $107.22 Plan Review - Fire Life Safety 05/13/2010 $65.98 Contractor: ABOVE ALL INSTALLATIONS LLC 16200 SW PACIFIC HWY TIGARD, OR 97224 PHONE: 503 - 969 -2506 FAX: Specifics: Type of Use: COM Class of Work: ALT Dwelling Units: 0 Stories: 0 Height: 0 ft Bedrooms: 0 Bathrooms: 0 Value: $5,800 Floor Areas: Total Area: 0 Accessory Struct: 0 Basement: 0 Carport: 0 Covered Porch: 0 Deck: 0 Garage: 0 Mezzanine: 0 Total $357.96 Required: Required Items and Reports (Conditions) 1 BUP Bolts in Concrete Fire Sprinkler: Parapet: Fire Alarm: Protected Corridors: Smoke Detectors: Manual Pull Stations: Accessible Parking: 0 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATT • • • - e •n law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952 -0r -0010 through OA' 152-•! 010* You may obtain a copy of the rules or direct questions to OUNC by calling 503.246.6699 or 1.800.332.2344. Issued By: 1 1 / C /�( � Permittee Signature: „ g- - i- --- . --- e - a. Call 503.639.4175 by 7:00 a.m. for an inspection that bf�siness day. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. Building Permit Application Commercial I ''` ��_ •' I O R OI I ICI - lltil O \'I 1 Ra E �� r ,_,: City of Tigard '�"`' DateB � Permit No.: t .. 13125 SW Hall Blvd., Tigard, OR 97223 Plan Revie� 1 -- .. 8 - Phone: 503.639.4171 Fax: 503.598.1960 MAY 1 . 2010 DateB : '\ /yj Other Permit: /l�1 t ••41 .:1" IG / it [3 Inspection Line: 503.639.4175 • Date Ready :y: n See Page 2 for Internet: www.tigard- or.gov CITY OF T1G . et Ai - . . 1 .i I 10 ` //BM Supplemental Information ILDING 91VIS10 TYPE OF WORK ; . REQUIRED DATA: 1- AND 2- FAMILY DWELLING 7. 0 New construction ❑ Demoliti B Uon Permit fees* are based on the value of the work performed. Indicate the value (rounded to the nearest dollar) of all ❑ Addition/alteration/replacement ❑ Other: equipment, materials, labor, overhead, and the profit for the CATEGORY OF CONSTRUCTION work indicated on this application. Valuation: $ ❑ 1- and 2- family dwelling Commercial /industrial ❑ Accessory building ❑ Multi- family Number of bedrooms: ❑ Master builder ❑ Other: Number of bathrooms: . JOB SITE INFORMATION AND LOCATION . Total number of floors: Job site address: 7 _sir0 7e lit 6 ,A a New dwelling area: square feet City /State /ZIP: T 75 6,7--- (0 q ?)- Z 3 Garage /carport area: square feet Suite/bldg. /apt. no.: J Project name: e 4 n Covered porch area: square feet Cross street/directions to job site: Deck area: square feet Other structure area: square feet REQUIRED DATA: COMMERCIAL -USE CHECKLIST Subdivision: Lot no.: Permit fees* are based on the value of the work performed. Tax map /parcel no.: Indicate the value (rounded to the nearest dollar) of all equipment, materials, labor, overhead, and the profit for the DESCRIPTION OF WORK work indicated on this application. 0 C ` / Cj S / p r. / ,5 5 — E iv Valuation: $ `�j�W Oil 1 4S -)41 /4 n .S r/ 0 & l/� 0- / Existing building area: square feet r 1/7 2/er -- 3 / New building area: square feet ❑ PROPERTY OWNER !TENANT Number of stories: Name: CO C.4' h Type of construction: Address: 7s 'Ti A Ce f , r ,a/' Occupancy groups: City /State /ZIP: Existing: Phone: (51'7 / \ ,/) U ( `( )q ? Fax: ( ) New: /APPLICANT [/CONTACT 'PE NOTICE • ■ Business name: d/ t /, All contractors and subcontractors are required to be Contact name: 3 !� - , /� /� licensed with the Oregon Construction Contractors Board l t under ORS 701 and may be required to be licensed in the Address: `7 J C ;, I/t-A t/ � / ,� jurisdiction in which work is being performed. If the City /State /ZIP: / applicant is exempt from licensing, the following reasons _ J apply: Phone: (S U S l4 J O 3 7 Fax: : (� (/ 1 ) (� �, 0 \_,5 - 3,, E- mail: CONTRACTOR Business name: /6A 6„k4 � BUILDINCPERMIT.FEES* Address: I � 0 �C a,ll t" s ., D 0 l � � h � � r' � l � � �� - (Please refer to fee schedule ' f 7 �/ Structural plan review fee (or deposit): - a City /State /ZIP: ,s / - . p 11 9 ?) 2 Phone: r q 0 q ,- O b Fax: ( ) FLS plan review fee (if applicable): 657 98 CCB lic.: C $,' a 7 (� Cv7s Total fees due upon application: 357. 1 (/ __ Amount received: 35-7. Authorized signature: This permit application expires if a permit is not obtained � within 180 days after it has been accepted as complete. Print name: e e- n f L4... Date:L7) * Fee methodology set by Tri- County Building Industry Service Board. 1:\Building\Permits \BUP -COM PermitApp.doc 10/01/09 440- 4613T(11/02 /COM/WEB) ° Building Division Accessibility: Barrier Removal Improvement Plan TI` D' REQUIREMENT: OREGON REVISED STATUTE (ORS) 447.241. (1) Every project for renovation, alteration or modification to affected buildings and related facilities shall be made to insure that the path of travel to the altered area and the restroom, telephones and drinking fountains are readily accessible to individuals with disabilities unless such alterations are disproportionate to the overall alterations in terms of cost and scope. (2) Alterations made to the path of travel to an altered area may be deemed disproportionate to the overall alteration when the cost exceeds twenty-five per -cent (25 %). VALUATION: Total of all renovation, alteration or modification being done, excluding painting and wallpapering: [1] $ MULTIPLIER (25% barrier removal requirement): x .25 TOTAL BUDGET FOR BARRIER REMOVAL: [2] $ ELEMENTS: In choosing which accessible elements to provide under this section, priority shall be given to those elements that will provide the greatest access. Elements shall be provided in the following order: (a) Parking $ (b) An accessible entrance: $ (c) An accessible route to the altered area: $ (d) At least one accessible restroom for each sex or a single unisex restroom: $ (e) Accessible telephones: $ (f) Accessible drinking fountains: and, $ (g) When possible, additional accessible elements such as storage and alarms: $ TOTAL (shall equal line [2] of Valuation Computation): $ 1: \ Building \Perrnits \BUP -COM PcrmitApp.doc 06 /25/08 - - RIGH-PILED COMBUSTIBLE STORAGE . I TABLE 2308.2 ,, e GENERAL FIRE PROTECTION AND UFE SAFETY REQUIREMENTS , ......... SOLID-PILED STORAGE, SHELF ALL STORAGE AREAS STORAGE AND ITILLEFIZED STORAGE (Soo SeetIons 2306,2307 end 23IISP (see Sseetkin 2807.11) Sf/E OFIRGII-POLJEO Padastelle Fire STORAGE AREA estflognisblus detection Bending Smoke and Dna (Mum tes4 lataidatem peandssible system system access beet removal surialtle &tsunamis stenos Main= CONINIODRY (see Sections 231/S.2 (see Section (see SocRon (see Seddon fess Secllon (see Sesame dbnenallorf beigNid Oa volume CLASS and MINA) 23811.414 =SS) =SA) 231163) 231621 time (bell (Gabbs fame gig 9-5110 Not Not Not Not Not Not Not Not Requited& Required Requite& Required Reedited Required Required Required Not Not Not Not 501-2,500 Yes' 100 40 100,000 Requile& Require Ruse ed Requited 2501-12,000 Not Not Not Not Yes 100 40 400,000 Public accessffile ` Not 7 Not 1 Not ' .Not Nonpublic acoeunirle Yes . Rooked F s.titexj „ , = Rooted 100 40 400,000 (Option 1) 1-IV 2501-12,000 Not Nonpublic accesslide Required Yes Yes • Yes* Yes* 100 30f 200,000 (Option 2) . Not Not 12,001-20,000 Yes ReQtaied Yes Yes* Reanhed 100 40 400,000 , Not 20,001-500,000 Yes Yes Yes* 100 40 400,000 Required Requited Greater than Not Not Yes Yes Yeti 40 400,000 500.000g • Required Requited 11 " Not Not Not Not Not Not Not 0-500 5 , Require& Required Required Required Requited Required Requited 501-2500 Y Not Not Not Not es 50 30 75,000 Public accesralle Required Require& Requited Required , 501-2,500 Not Not Not Not Nonpublic Yes MO Required Requite& Requited Raga ad 50 30 75,000 (Option 1) hazard 501 Not Vogpublic Yes Yes Yes* Yes' 50 20 50,000 Requke& (Option 2) Not Not 2,501-300/110 Yes Yes Yed 50 30 75,000 Required 1 Required Not Not 300,001-500,000"A Yes Required Required Yes 1 Yes* 50 - 1 30 75,000 - I For SI: 1 foot =304.3 nun. 1 cubic foot =0.02832 m 1 square foot = 0.0929 m a. When automatic sprinkling are tenoned for reasons other Gan those in Chapter 23, the poition of the spridder system inotecting tbe higb-piled storage area shall . be designed and 'installed in stccordance smith Sections 2307 and 2308. , b. For aisles, sae Section 2306.9. c. Piles shall be separated by aisles complying with Section 2306.9. it For storage in excess of the height indlcated, special Tire protection shall be provided is accordance with Note g when required by the fne code official. See also Chapters 28 and 34 for special limitations for aerosols and flammable and combustible liquids. e. Section 503 shall apply for fire apparatus access. f. For storage matting 30 feet in height, Option 1 shall be used. g. Special fire protection provisions including, list not hunted to, fire protection of exposed steel cobanns; increased sprinkler density; adtfaional in-mack spriidders, without associated reductions in ceningsprinklerdeaskr or additional fun departmentbose connections shall be provided when required by die fire code official. h. High-piled storage areas shall note/rectal 500,000 square feet. A 2-hotwfire wall construcbxlin accordance with the larenitaional Building Code shall be used to divide high-piled storage exceeding 500,00D square feet ht area 1. Not reqnhed when an automatic fireextinguishing system is designed and installed to protect the high-piled storage area in accordance with Sections 2307 and 2308. . I j. Not required when storage areas are protected by early suppressn fast response (Milt) sprinkler systems installed in accordance with NFPA. 13. From: 05/27/2010 10:38 #733 P.002/002 • I II( HI SPECIAL INSPECTION • !:n1er Dr., Suite 145 , OR 97223 • 503.443;3799 Phone: 503 -443 -3799 Fax: 503-620-2748 Date: Job # 10 -2872 -009 Permit # BPU2010 -00100 Mail To: Project : NORLIFT OF OREGON, INC C0008 PO Box 68348 (Cichran, Inc) PORTLAND OR 97268 7550 SW Tech Center Dr, #220 Portland, OR 97223 To Whom It May Concern: ACS Testing, Inc. attests that their inspectors performed special inspection(s) on a continuous and/ or periodic basis as required by the specific jurisdiction and /or IBC. Special inspection(s) were performed for the following: ❑ Structural Steel E3 Proprietary Anchors ❑ High Strength Bolts El Structural Masonry ❑ Shotcrete ❑ Wood Nailing ❑ Reinforced Concrete Other: Based on personal observation, inspection and reports reviewed by me for the above project, I attest on behalf of ACS that work was performed to the best of my knowledge, in accordance with approved plans, specifications, and the applicable codes and standards for this jurisdiction. Approved by: !. �' �' __.. BOB Brown/President c dll2 - 75A0 BB /sa