Loading...
Permit a CITY OF TIGARD FIRE PROTECTION SYSTEM PERMIT COMMUNITY DEVELOPMENT Permit #: FPS2010 -00046 a t Date Issued: 05/21/2010 "TIGWRD 13125 SW Hall Blvd., Tigard OR 97223 503.639.4171 Parcel: 1S135AB03400 Jurisdiction: Tigard Site address: 10260 SW GREENBURG RD 900 Subdivision: LINCOLN TOWER Lot: 0 Project: NW Mortgage Expansion Project Description: Fire alarm Owner: FEES LINCOLN CENTER LLC Description Date Amount BY SHORENSTEIN PROPERTIES LLC, 555 CALIFORNIA ST 49TH FL Permit Fee - COM 05/20/2010 $123.72 12% State Surcharge - Building 05/20/2010 $14.85 PHONE: Plan Review - Fire Life Safety - COM 05/20/2010 $49.49 Contractor: CAPITOL ELECTRIC CO INC 11401 NE MARX STREET PORTLAND, OR 97220 PHONE: 503 - 255 -9488 FAX: 503 - 257 -7121 Type of Use: COM Class of Work: ALT Type of Const: IB Occupancy Grp: B Height: ft Stories: 12 Commercial Sprinkler System: Sprinkler Required: Sprinkler Type: Standpipe Required: Hazard: Density: 0 Design Area: 0 K Factor: 0 Commercial Fire Alarm System: Fire Alarm Required: Yes Alarm Type: Automatic Pull Station Required: Yes Smoke Detectors Req: No Battery Calcs Provided: Yes Cut Sheets Required: Yes Total $188.06 Valuations: Required Items and Reports (Conditions) Sprinkler Valuation: 0 Residential Square Footage: 0 Fire Alarm Valuation: 4600 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952 - 001 -0010 through OAR 952 - 001 -0100. You may obtain a copy of the rules or direct questions to OUNC by calling 503.246.6699 or 1.800.332.2344. Issued By: Permittee Signature: al 7Cfe- Call 503.639.4175 by 7:00 a.m. for an inspection that business day. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. Building Permit Application Q ',. ff �� S f r Q t `. � M • crXX Fire Protection System ! t•, ry: k; Y r ,FOR� . ;. . - r�ww 1 iw.� +wei:�a.d�1..M rrALrs...w4..+� -•a.r .v.n -:ia:� 4.a City of Tigard �q T}�'! Received Q /� �j� ,; :i. v a CE / M"� i;,? . • .I Permit No.: e-`SADf` J — Jy 13125 SW Hall Blvd., Tigard, OR 97223 RECEIVE �I JIJ D ate /Bv: Y �� g jl�g/ Plan Review 174 .. "'ail' Phone: 503.639.4171 Fax: 503.598.1960 Date /Bv: ii M(® Other Permit e a a gidri1tD Inspection Line: 503.639.4175 n 2 7 2010 Date Ready /By: 1� ,i ® See Page 2 for r4nMwll wfl � Internet: www.tigard - or.gov AP L+ Notified/Method:5 i' 1 Supplemental Information • I10F TIGARD SPvuc w Ekvv • TYPE OF WB E QUIREDDATA:1 -AND2- FAMILY DWELLING ❑ New construction ❑ Demolition Permit fees* are based on the value of the work performed. Indicate the value (rounded to the nearest dollar) of all ® Addition /alteration /replacement ❑Other: equipment, materials, labor, overhead, and the profit for the CATEGORY OF CONSTRUCTION work indicated on this application. ❑ 1- and 2- family dwelling ® Commercial /industrial Valuation: 5 El Accessory building ❑ Multi- family Number of bedrooms: II] Master builder ❑ Other: Number of bathrooms: JOB SITE INFORMATION AND LOCATION Total number of floors: Job site address: 10260 SW Greenburg Rd. (Lincoln Tower) New dwelling area: square feet City /State /ZIP: Tigard., OR 97223 Garage /carport area: square feet Suite/bldg. /apt. no.: Floor 9 Project name: NW Mortgage T.I. Covered porch area: square feet Cross street/directions to job site: Deck area: square feet Other structure arca: square feet .... REQUIRED DATA: COMMERCIAL - USE CHECKLIST Subdivision: Lot no.: Permit fees* are based on the value of the work performed. Tax map /parcel no.: Indicate the value (rounded to the nearest dollar) of all equipment, materials, labor, overhead, and the profit for the DESCRIPTION OF WORK work indicated on this application. Install Fire Alarm Strobes in 9 Floor Tenat Spaces Valuation: $4600 Existing building area: square feet New building area: square feet ® PROPERTY OWNER ❑ TENANT Number of stories: Name: Shorenstein Realty Services Type of construction: Address: Occupancy groups: City /State /ZIP: Existing: Phone: ( ) Fax: ( ) New: ❑ APPLICANT ❑ CONTACT PERSON • NOTICE Business name: All contractors and subcontractors are required to be Contact name: licensed with the Oregon Construction Contractors Board under ORS 701 and may be required to be licensed in the Address: jurisdiction in which work is being performed. If the City /State /ZIP: applicant is exempt from licensing, the following reasons apply: Phone: ( ) Fax::( ) E -mail: CONTRACTOR BUILDING PERMIT FEES* Business name: Capitol Electric Company, Inc. (Please refer ro fee schedule) Permit fee: 123.72 Address: 11401 NE Marx Street State surcharge (12% of permit fee): 14.85 City/State /ZIP: Portland, OR 97220 n FLS plan review (40% of permit fee): " e e19 —. Phone: (503) 255 - 9488 Fax: (503) 255 -1966 (Due upon application.) 1 CCB lic.: 48748 6 o- Total permit fees: i qq. °(11 • ��' Amount received: 1. Authorized signature: I This permit application expires if a permit is not obtained Print name: Dan Wilson Date: 10/3/08 within 180 days after it has been accepted as complete. * Fee methodology set by Tri- County Building Industry Service Board. 1: \Building\Pennits \FPS - PermitApp.doc 03/23/06 440- 4613T(11 /02 /COM /WEI3) p 9 NFPA -72 Fire Alarm System Record of Completion Date :; 6/23/2010 1" City of Tigard Information: Permit No( FPS2010 -00046 Name of protected property: NW MORTGAGE TENANT IMPROVEMENT, SUITE 960 @ LINCOLN TOWER Address of protected property: 10250 SW'GREENBERG'.ROAD TIGARD, OR 97223 • Representative of protected property (name /phone): SHORENSTEIN RELATY SERVICES Authority having jurisdiction: City of Tigard, Building. Services Address /telephone number: 13125 SW Hall Blvd. Tigard, OR 97223 (503) 639 4171 1. Type(s) of System or Service NFPA 72, Chapter 5 •.Proprietary J,,. i. If alarms are retransmitted to public fire service communications centers or others, indicate location and telephone numbers of the organization receiving alarm: Indicate how alarm is retransmitted: X NFPA 72, Chapter 5 -- Remote Station Prime contractor: Simplex - Grinnell Central station location: Means of transmission of signals from the protected premises to the central station: McCulloh Multiplex One -way radio Digital alarm comrnunicator Two -way radio Others Means of transmission of alarmsto the public fire service communications center: (a) (b) System location: Organization name /phone Representative name /Phone Installer Capitol Electric Co. Inc, Dan W. Wilson 503 '255 -9488 Supplier Capitol Electric Co. Inc. Dan W. Wilson 50S -255 =9488 Service organization Capitol ,Electric Inc. Dan W. Wilson 503 255 -9488 Location of record (as- built) drawings: Location of owners manuals: Location of test reports: A contract, dated for test and inspection in accordance with NFPAstandard(s) No(s). , dated , is in effect. n; 2. Record of System Installation Suite 960 Only (Fill out after installations complete and wiring checked for opens, shorts, ground faults, and improper branching, but prior to conducting operational °acceptance tests.) This system has been installed in accordance with the NfPA standards as shown below, was inspected by Dan Wilson on 06/23/10 , included the devices shown below, and has been in service since 06/23/10 . x NFPA 72 (2007), Chapters 1 2 3 4 5 .6; 7 (underline all that apply) x NFPA 70 (2008), National Electrical Code, Article 760 x Manufacturer's instructions Other (specify): Signed: Date: Organization: Capitol Electric Company, Inc. ,3 : "' Record of System Operation Suite 960 Only All operational features and functions of this system were tested by Dan Wilson on 06/23/10 and found to be operating properly'.in accordance with the requirements of: x NFPA 72 (2007), Chapters 1 2 3 4. 5 6 7 (underline all that apply) x NFPA 70 (2008), National Electrical Code,, Article 760 x Manufacturer's instructions Other (specify): Signed: Dan Wilson Date: 6/23/2010 Organization: Capitol Electric Company, Inc. 4. Alarm- Initiating Devices and Circuits Suite 960 Only Quantity and class of initiating device circuits (see NFPA 72, Table 3 -5) Quantity : Style: Class: MANUAL (a) 0 Manual stations Noncoded, activating Transmitters Coded .(b) Combination manual fire alarm and guard's tour coded stations. AUTOMATIC Coverage: Complete: Partial: (a) 0 Smoke detectors Ion Photo (b) 0 Duct detectors Ion Photo (c) 0 Heat detectors FT RR FT /RR RC (d) 0 Sprinkler ,waterflowswitches: Transmitters Noncoded, activating (e) Other (list): 5. Supervisory Signal- Initiating Devices and Circuits Suite 960 Only SPRINKLER SYSTEM (a) Non coded valve supervisory switch at sprinkler riser (b) Non coded valve supervisory switch at sprinkler vault (c) Non coded supervisory air pressure switch at sprinkler riser (d) Site water supply level points Other supervisory functions(s) (specify): 6.. Alarm Notification Appliances and Circuits Suite 960 Only Quantity and class (see NFPA 72, Table 3 -7) of notification appliance circuits connected to the system: Types and quantities of notification appliances installed: Quantity: #REFI Style Y Class: B (a) Bells Inch (b) 2 Speaker /Strobes (f) . 23 Visual signals Type: ADA SYNCHRONIZED with audible 23 w/o audible (g) Local annunciator Signaling Line Circuits Suite 960 Only Quantity and class (see NFPA 72, Table 3 -6) of signaling line circuits connected to system: Quantity: Style: . Class: 8. System °Power Supplies (Notification Panel NAC 9.1) (a) Primary (main): NAC 9.1. Nominal voltage: 120 VAC Current rating: 2.5 Amps Overcurrent protection: Type: Circuit: Breaker Current rating: 20 Amps Location: FLOOR 9 ELECTRIC ROOM (b) Secondary (standby): X Storage battery: Amp -hour rating: 7 Ah @ 24 VDC Calculated capacity to drive system, in hours: 3.04 Ah 24 60 9 : 'System Software (a) Operating system software revision level(s): N/A (b) Application software revision level(s): (c) Revision completed by: N/A (name) (firm) 10. Comments: Dan Wilson Capitol Electric: Co., FLS Supervisor (signed) for central station or alarm service company or installation contractor /supplier (title) Frequency of routine tests and inspections, if other than in accordance with the referenced NFPA standard(s): This record of completion applies to Suite 960 Only Devices installed conform'to NFPA standards. System deviations from the referenced NFPA standard(s) are: NONE Dan Wilson Capitol Electric Co., FLS Supervisor (signed) for central station or alarm service . company or installation contractor /supplier (title) Upon completion of the system(s) satisfactory test(s) witnessed (if required by the authority having jurisdiction): (signed) representative of the authority having jurisdiction (title) (date) Capitol Electric Co. Inc. CEIVED , APR 2 1M CITY OFTIGARD April 22, 2010 BUILDING DIVISION Plans Examiner City of Tigard Building Services 13125 SW Hall Blvd. Tigard, OR 97223 Re: Tenant Fire Alarm System Additions NW Mortgage Tenant Expansion, Suite 960 @ Lincoln Tower 10260 SW Greenburg Road Tigard, OR 97223 Please find attached a building permit application, Tri- County Commercial Application Checklist, three sets of plans, calculations, and product submittals for the fire alarm tenant improvements at the address shown above. Occupancy Group: B -High Rise The fire alarm system design includes the following: 1. Install ADA synchronized fire alarm evacuation strobes in the tenant space per plans. 2. Voice evacuation loudspeakers exist above the ceiling throughout the floor. 3. We will pre -test the fire alarm devices prior to requesting a final fire alarm inspection. Please contact me if you have questions or comments. Respectfully, Dan Wilson Project Manager /Estimator Fire /Life Safety Division Capitol Electric Company, Inc. (503) 255 -9488 dan @cepdx.com NICET Level IV, Fire Alarm Systems #104512 11401 NE Marx • Portland, Oregon 97220 -1041 • 503 - 255 -9488 • Fax 503 -257 -7121 CCB# 48748 • www.capitolelectricco.com