Loading...
Permit ' ' ` j CITY OF TIGARD MECHANICAL PERMIT 2 :. COMMUNITY DEVELOPMENT Permit #: MEC2010 -00012 7IGARD 13125 SW Hall Blvd., Tigard OR 97223 503.639.4171 Date Issued: 01!29/2010 Parcel: 1 S126CC00100 Jurisdiction: TIGARD • Site address: 9700 SW WASHINGTON SQUARE RD Subdivision: Lot: 0 Project: Nordstrom Project Description: Ductwork and diffuser modifications and demo. Owner: FEES PPR WASHINGTON SQUARE LLC Description Date Amount C/O NORDSTROM, ATTN: TAX DEPT, PO BOX Permit Fee 01/29/2010 $6,988.71 2229 12% State Surcharge - Mechanical 01/29/2010 $838.65 PHONE: Plan Review 01/29/2010 $1,747.18 Contractor: PSF MECHANICAL INC 9322 14TH AVE S SEATTLE, WA 98108 PHONE: 206 - 764 -9663 FAX: 206 - 826 -3569 Type of Use: COM Class of Work: ALT Type of Const: IIB Occupancy Grp: M Occupancy Load: Stories: 2 Fuel Air Handlers Fuel Types: Units < 10000 cfm: _ Gas Pressue: Units > 10000 cfm: Furnaces Boilers &'Compressors Furnaces < 100K BTU: 0 -3 HP: Furnaces >= 100K BTU: 3 -15 HP: Floor Furnaces: 15 -30 HP: Unit Heaters: 30 -50 HP: Vents w/o Appliances: 50 or Greater HP: Air Conditioning: Heat Pump: Appliances Vent Fans: Vent Systems: Total $9,574.54 Hoods: Comm Incinerators: Woodstoves: Gas Fireplaces: Required Items and Reports (Conditions) Clothes Dryers: Other Mech Units: Gas Outlets: Other Desc: Duct Work: 1 Fire /Smoke Dampers: This permit is issued subjectto the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utilit tification - •ter. Those rules 'are set'forth in OAR•952- 001 -0010 through OAR 952 - 001 - 0100. You may obtain a copy of the rules or erect questions to O, NC b, :fling 503.246.6699 or 1.800.332.2344. Issued By: / ' L,' jL , ; j • Permittee Signature: ( A O, Call 503:639:4175 by 7:00 a.m. for an inspection that business day. This permit card shall berkept`in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. n - ,ti ,-;-a. .. McchRnical: Permit A: li ion D N P } * • 4 rr tr , a., -� : i, � t , p t 4644tt a� �,,0', .,10_4,QFFICE,US 01L1' �t , , f,-fo. . • w '*. a 1 =m* 5 „ r, a, fx M' , � � r LkRi« xtrn l9 400# .City of Tigard "• d h , r, : - �,, ,, V 1 'I'ennil Nn :li 1 I 0/ � 61 ° , SW H YlI Rlvd, Tigard, OR 97223 !II' s+ r ' - ' ^ o_ , • o Phone-. 503.639 1 , Fax: .503.5%i-196 Detc /13y: rek Other Permit. r 1(ARlD. ' lnsptxtinn I mo: 503, 639.4175 Date Ready tar s: ru' ." illle[tlel:. . libard- or -gov N S -y: 61 See Page - 2 for JAN 1 1 2010 otifiedime'h°d: 7 .(.Q - / . 1 ( l - . Supplemental information k � "i ''1�1 s 'gym . yy t •� 1i 1. P ,,'Y ill S�Y' 401 . vgt fit '117' r : yet r w T ' :.. tiYrltRkl, l .1i. n I l ^ i iii i r �ti 1, { '4' d 4 a 't' J)E �r e I I r, t Y ,�itY l S 1r: 1 �( I t r �9R i err n,i �,�� ,,{�.,� ����IIil11Et >; !f hl:.r� �� ��� t, ��;��i8 1�� 'I6��� `: �sl�' �2�2��5�1 ���k��� ' ' 1 L • I S f r 1 IIC 'Sri r M Jvlvfu, r5 ❑ New construction ® Addition/a1tc e0' M I IIEDIVISION Mechanical permit tees" are based on the value of the work performed. Indicate the value (rounded to the nearest dollar) of all ❑ Demolition ❑ Olha'r: m echanical m aterials, equipment, l abor,•overheid, and prof r r/''rrC? I *M t 0, nr af[. 7 t value: ` {{ ff ,ky [;��` $ $250,000 .00 iig,0, r!da .�nro min o I i^'•lY/1 A ta ...$G el1R. �. •e „r t, ,II . • 1 i AS N , . N , era li�i. - ,,,.,,., a.. / li d II Tr x e c. r , , Xo a d i hi�Ji $i IIilI J PEOe.,, ..• F „r � � 4 CI 1- and 2- family dwelling ®Com merciaUinduslrial 111 AeovNsory building , dhy tea , r ±rl,I R (M,A, ", ; "l4 °k III Multi-family ❑ Master builder Other: horspecial inJUrntntion use ''checklist Description y r3 I I t , a IEIE ii Qty. 1 Ea. Total y .... Yo tlE Y'" f i� k yi p , P it ilia I. " a1f9 AI K>t,iiiik , - � .. . J . .t r l h lealeit: d ni�I140 i • " I lcatin - Job Site address: 9700 SW Washington Square Road Air conditioning (requires site Plan showing placement) 46.75 City /State /ZIP: Tigard, Oregon 97223 -4480 Furnace 100,000 BTU (ducts /vents) 46.75 Furnace 100,0001 BTU (ductaiventr.) 54.91 Suite /bldg. /apt, no.: -- Project name. H pu,,,l, 6 1.1.16 Cross street /directions to job rile_ N Duct work 23.32 -�� Y Hyd Uot water sy ii 23.32 Re id h oilcr (radiator or hydrr 23.32 Unit h eaters (fuel - t y pe, not electric), in -w in - duct, su ctc. 46.75 _ _: Flue/vettt for.any of above 23.32 Subdivision: Lot nu _.,. Other; 23,32 'fax map /parcel no.: 1S126CC00100 Other fuel`'applinnars l Il tote t I rltii �. ' I I J ^� , ,l ( {Lfli �l lrt', 1[eu(er . 1 .ft;i:E , k',3n �;. � , Nrl i'� .C4:'�i'I , mot ff NI,e, g t.. t , i 1if .. , I i�v,l ,; i Wt ..- _ 23.32 Gas fiieplace 33,39 Ductwork and diffuser modifications,, demolition _ Flue vent for water hcotcr or gas tircplacc 23.32 - -- - I. lighter (pas) 23.32 Wutxi /pelle( stove 33.39 Wood fireplace/insert 23.32 ° "'4 (I ' , • his t0 y� I u p . ` _� gg p� ,: . ,r n o �•,1 0 JJ y8 M 1 n Chiuutry /liner /[Iurlvenl 23.32 ..� , ) 1+�1.Y'P` � ' ' �t 9 Xi� , ►�.,, ��� � .��R rlI1II1' a t m,t "' I O t her : 2 Name: Nordstrom inc • Environmental exhaust and ventilation _ Address: 1700 7 Avenue, Suite 1000 Range hood /other kitche • equipment 13.39 City/State/ZIP: Seattle, WA 98101 -4407 . Clothes dryer exhaust. 33.39 Single -duct exhaust (bathrooms, Phone, (206)303 - 4300 Fax: (206)3034319 toilet compartments, utility rooms) 23.32 �!� a t ,, d . , l '14 1 6 f o , r 0.A A , 1,1801 Pl?i?> 4 '' fYT , f " l IIIIa8 n <:. A L 0,,N,, .II 10.1 M Attic rawlspacc ., 23.32 I [, it .t r �: >t 1 . F uel 23.32 Business nattic: PSF Mechanical inc . - - Fuel piping Contact name: Sabrina Roberts $14.15 for first four; $4.03 far each additional Address: 9322 ;14' Avenue South Furnace, etc_ _.... .---- Gas heat pump .City/State /ZIP: Seattle, WA 98108 - 5102 Wall /suspendc&unitheater Phone: (206) $26 =3568 Pax:: (206) 826 -3569 Water heater • - Fireplace E -mail: sroberts@psfrnech.com Range 1 ,' :c 17.(1 ll r (I+rr -c r v 4 ! e ^• 'tit 1't', $ l L r t , I'r L : I '. , � �i,�i' � 19ftJ 4A �I hN � i f' a ��@ „ "r 11» M9 r I Barbecue Business name: PSF Mechanical Clothes diyer (gas) Other: • Address: 9322 14 Avenue South ":1 r T," w'.t) , 'II. I ll'1 R , . a 1 ; A �., r nt, ,% J l City /State/ZIP: Seattle, WA 98108 -5102 , Subtotal Minimum permit fee ($90.00) Phone (206)-826 -3568 Fux; (206) B26 -3569 Q Plan review (25% of permit fee) _ CCti Iic.'-F2989=`' -1 030Z State surcharge (12% of permit fee) TOTAL PERMIT FEF. Authorized signature This permit applicariun expire% if a permit k not obtained within 180 days after It bit n accepted ax complete. Print name: Sabrina Roberts _ Date: 1/11/10 * Fee methodology set by Tri- County tiuiidilie Iuelaslry Service. Hoard 1: Landing \t'grmit.soniC- Yer,atAW,Jrre 15/01/09 445-4U,17 (1 I m NCOhUW[D) 2,2 :a6ed 096I86S2OSI :ol ti82829L902 1UDIN3H33W dSd :WO *d 92 :Si 0 02- -Iti -NUf CERTIFIED TEST AND BALANCE REPORT B vne-c�i u_ 006(2 PIE0zo) D -- 00115 PSF Mechanical, Inc. 9322 14th Avenue South Seattle, Washington 98108 T 206.764.9663 Project Name: Washington Square PSF Job #: 1881 Project Address: 9700 SW Washington Square RD Tigard OR 97223 Customer: Nordstrom Engineer Name: Mark Kaminski TAB Supervisor: Chris Grantham Date: 9/17/2010 I t . (3" Test Adjust Balance (TAB) Summary Report 1 ; Project Name: Project Number: This project has been surveyed and balanced per plans and specifications, unless otherwise noted. Each system has been balanced using the National Environmental Balancing Bureau (NEBB) standards and procedures. Unit Service Equipment Floor Actual % of Floor Design Actual OA Remarks Submittal Design CFM Design OA CFM CFM AC1 1ST FLOOR W 45000 47975 34600 77% 8500 6700 AC2 1ST FLOOR E 40060 39335 35889 91% 8500 6935 AC3 2ND FLOOR W 45000 45020 32824 73% 9000 6100 AC4 2ND FLOOR E 45000 41680 38551 92% 9000 8558 AC5 EMPLOYEE OFFICES 10000 6920 6152 89% 1500 wont MIN AC6 TAILOR 1ST FLOOR 5000. 5005 4626 92% 105 105 AC7 ALTERATION 2ND FLOOR 5000 4680 4908 ' 105% 120 120 AC8 CAFE 2ND FLOOR 6000 6100 5286 87% 1305 broken AC9 KITCHEN 2ND FLOOR 3000 3000 2940 98% 75 0 no econo AC10 1ST & 2ND FLOOR STOCK 9600 8760 8717 91% 960 942 �-- _ AC11 SECURITY 1200 1200 1235 103% 45 45 AC12 TEL/POS 1ST FLOOR 1600 1600 1750 109% 60 60 AC13 LOUNGE NORTH 1200 1200 1482 124% 330 360 AC14 LOUNGE SOUTH 1200 1220 1518 124% 330 350 AC15 COUNTING ROOM 700 700 625 89% 100 no control REMARKS: Date: By: ( F Test Adjust Balance (TAB) Summary Report , 7 BB Project Name: Project Number: This project has been surveyed and balanced per plans and specifications, unless otherwise noted. Each system has been balanced using the National Environmental Balancing Bureau (NEBB) standards and procedures. Unit Service Equipment Floor Actual % of Floor Submittal Design CFM Design CFM CFM - EF 1 FREIGHT ELEV MACHINE 1150 1150 1075 93% EF 2 RESTROOMS 5000 6385 4126 64% EF 3 TAILOR 6000 6000 6275 105% EF 4 ALTERATIONS 7100 7100 7080 100% EF 5 HD 1 KITCHEN 2200 2200 2638 120% EF 6 HD 2 KITCHEN 3400 3400 2950 87% EF 7 TRASH ROOM 600 600 530 88% _ EF 8 BEAUTY STUDIO 500 500 470 94% EF 9 DISPLAY WORK RM 1860 1860 1415 76% EF 10 PASSENGER ELEV. MACHIN 1150 1150 1040 99% EF 11 WOMENS TOILET 1170 670 685 102% le EF 12 STORAGE ROOM 500 500 250 495% EF 13 MAINTENANCE 2500 2500 2280 91% TF 1 E BAR 500 500 500 100% REMARKS: P Date: By: ii. ('\*.x..."(21171SP VAV SYSTEM SUMMARY REPORT f . -� Project: Nordstrom at Washington Square System: AC 1 Service: FIT & VAV Boxes DESIGN PRIMARY CFM ACTUAL PRIMARY CFM DAMPER % % OF I.D. Box Size MAX MIN MAX MIN VAV /C ox @ MAX DESIGN CFM (I /s) CFM (Vs) CFM (I /s) CFM (I /s) FLOW MAX CFM FIT 101 12 1990 400 1280 - 400 1.09 100% 64% FIT 102 8 610 130 415 130 1 100% 68% FIT 103 10 1310 260 1275 260 1.02 97% 97% FIT 104 8 1080 220 945 220 DAMPER 100% 88% FIT 105 5 200 40 200 40 1 49% 100% FIT 106 8 360 100 345 100 1.02 46% 96% FIT 107 8 1020 210 690 210 1.01 100% 68% FIT 108 8 700 140 655 140 1 100% 94% FIT 109 10 1500 280 935 280 0.99 100% 62% FIT 110 8 1130 230 450 230 1.01 100% 40% FIT 111 8 900 200 525 200 1 100% 58% ONO FIT 112 6 530 110 305 305 1.02 100% 58% FIT 113 8 950 200 590 200 1 100% 62% FIT 114 8 955 200 525 200 1 100% 55% FIT 120 10 1350 270 915 270 1.02 100% 68% VAV 101 16 4350 1090 3775 1090 1 100% 87% VAV 102 16 4350 1090 3710 1090 1.02 100% 85% VAV 103 16 3480 870 3235 870 1.02 100% 93% VAV 104 14 2610 660 2205 660 1.09 100% 84% VAV 105 16 4350 1090 2535 1090 1.09 100% 58 %0 _ VAV 106 10 1740 440 895 440 1 100% 51% VAV 107 16 4350 1090 2665 1090 1 100% 61% VAV 108 16 3480 870 2150 870 1 100% 62% VAV 120 16 3480 870 2920 870 1 100% 84% VAV 121 10 1200 0 460 0 1 100% 38% TOTAL 47975 11060 34600 11255 72% REMARKS Date: NOVEMBER Readings By: NW ri7-F t VAV SYSTEM SUMMARY REPORT BB Project: Nordstrom at Washington Square System: AC 2 Service: FIT & VAV Boxes DESIGN PRIMARY CFM ACTUAL PRIMARY CFM DAMPER % % OF I.D. Box Size MAX MIN MAX MIN VAV /C ox @ MAX DESIGN CFM (Ws) CFM (Vs) CFM (Ws) CFM (I /s) FLOW MAX CFM FIT 115 12 1225 400 1270 400 0.92 35% 104% FIT 116 6 500 100 510 100 1.01 100% 102% FIT 117 6 570 120 465 120 1 100% 82% FIT 118 12 760 150 2028 150 1.01 42% 267% FIT 119 5 250 50 240 50 1 100% 96% VAV 109 16 4350 1090 4480 1090 1.05 57% 103% VAV 110 16 3480 870 3490 870 1.08 76% 100% VAV 111 16 3480 870 3395 870 1.08 52% - 98% VAV 112 16 4350 1090 4141 1090 1.01 99% 95% b VAV 113 10 650 170 630 170 1 75% 97% VAV 114 16 3480 870 3530 870 1.06 64% 101% VAV 115 10 1200 300 1285 300 1.05 100% 107% VAV 116 10 1400 350 1245 350 0.98 100% 89% VAV 117 16 4350 1090 4075 1090 1 100% 94% VAV 118 16 4110 1030 DAMPER 1030 DAMPER DAMPER VAV 119 16 3880 970 3725 970 0.9 100% 96% VAV 122 10 1300 0 1380 0 1 100% 106% TOTAL 39335 9520 35889 9520 91% REMARKS PO Date: NOVEMBER Readings By: NW . . • :. VAV SYSTEM SUMMARY REPORT L EJ B T 1 . Project: Nordstrom at Washington Square System: AC 3 Service: FIT & VAV Boxes DESIGN PRIMARY CFM ACTUAL PRIMARY CFM DAMPER % % OF I.D. Box Size MAX MIN MAX MIN VAV /C ox @ MAX DESIGN CFM (Us) CFM (Ws) CFM (I /s) CFM (Us) FLOW MAX CFM FIT 214 8 1100 220 780 220 1.01 100% 71% FIT 215 6 480 100 340 100 1.03 100% 71% FIT 216 6 660 140 337 140 1 100% 51% FIT 217 10 1400 280 1025 280 1 100% 73% FIT 218 10 1680 300 1150 300 1 100% 68% FIT 219 12 1650 400 1255 400 1.02 100% 76% FIT 220 10 1640 330 988 330 0.98 100% 60% FIT 221 8 1010 220 284 220 1.02 100% 28% FIT 233 14 1500 320 1542 320 0.97 74% 103% rr VAV 201 16 3600 900 2850 900 1.1 100% 79% VAV 202 16 3600 900 3340 900 1.11 100% 93% VAV 203 16 3600 900 3015 900 1.07 100% 84% VAV 204 16 3600 900 3120 900 1.08 100% 87% VAV 205 12 1800 450 1529 450 0.91 100% 85% VAV 206 14 2700 680 1525 680 0.81 100% 56% VAV 207 16 3600 900 3065 900 1.11 100% 85% VAV208 16 3600 900 1905 900 DAMPER 100% 53% VAV 209 16 3600 900 1960 900 0.96 100% 54% VAV 210 14 2700 680 1720 680 1.01 100% 64% TOTAL 43520 10420 31730 10420 73% REMARKS Date: NOVEMBER Readings By: NW , .,.. .- VAV SYSTEM SUMMARY REPORT EJ OB Project: Nordstrom at Washington Square System: AC 4 Service: FIT & VAV Boxes DESIGN PRIMARY CFM ACTUAL PRIMARY CFM DAMPER % % OF I.D. Box Size MAX MIN MAX MIN VAS /Cox @ MAX DESIGN CFM (Vs) CFM (Ws) CFM (Ws) CFM (I /s) FLOW MAX CFM FIT 222 10 1680 340 1585 340 1 78% 94% FIT 223 6 660 140 350 140 1.01 100% 53% FIT 224 8 1100 220 605 220 1 100% 55% FIT 225 8 1080 230 880 230 1 100% 81% FIT 226 10 960 200 930 200 1 43% 97% FIT 227 6 700 140 520 140 0.97 100% 74% FIT 228 8 960 200 960 200 1.03 79% 100% FIT 229 10 1200 270 1195 270 1.01 100% 100% FIT 230 10 1410 230 1390 230 1.14 60% 99% FIT 231 8 840 200 810 200 1 95% 96% FIT 232 10 1330 270 1280 270 1 80% 96% VAV 211 16 2600 900 3570 900 - 1.12 72% 137% VAV 212 6 450 200 348 200 1.07 53% 77% VAV 213 6 310 80 310 80 1.07 53% 100% VAV 214 14 2700 680 2625 680 0.95 57% 97% VAV 215 16 3600 900 3555 900 1.03 49% 99% VAV 216 14 2700 680 1735 680 1.04 100% 64% VAV 217 14 2700 680 1695 680 0.96 100% 63% VAV 218 16 3600 900 3390 900 1.04 100% 94% VAV 219 12 2100 530 2075 530 0.99 ' 60% 99% VAV 220 14 2700 680 2535 680 0.95 100% 94% VAV 221 14 2700 680 2415 680 0.9 100% 89% VAV 222 16 3600 900 3793 900 1.08 100% 105% TOTAL 41680 10250 38551 10250 92% A REMARKS Date: Readings By: • . lik (6;4:5 VAV SYSTEM SUMMARY REPORT Project: Nordstrom at Washington Square System: AC 5 Service: FIT & VAV Boxes DESIGN PRIMARY CFM ACTUAL PRIMARY CFM DAMPER % % OF I.D. Box Size MAX MIN MAX MIN VAV /C ox @ MAX - DESIGN CFM (Us) CFM (Ws) CFM (I /s) CFM (Us) FLOW MAX CFM FIT 201 12 1660 400 1680 400 1 31% 101% FIT 202 6 560 80 565 80 1.01 51% 101% FIT 203 5 _ 190 30 195 30 1 24% 103% FIT 204 5 220 50 225 50 1 34% 102% FIT 205 8 580 200 602 200 1.02 50% 104% FIT 206 6 400 80 345 80 1 100% 86% FIT 207 5 175 40 180 40 1 35% 103% FIT 208 5 210 50 215 50 1.02 26% 102% FIT 209 6 360 80 285 80 1 100% 79% FIT 210 5 315 70 268 70 1 100% 85% I____ FIT 211 6 500 100 265 100 1 100% 53% FIT 213 12 1750 380 1327 380 1.02 100% 76% TOTAL 6920 1560 6152 1560 89% REMARKS 0 Date: NOVEMBER Readings By: NW