Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Permit
Ip ii u� l �` CITY OF TIGARD MECHANICAL PERMIT a COMMUNITY DEVELOPMENT Permit #: MEC20'10 00182 ° Date Issued: 06/23/2010 T i 'ARD 13125 SW Hall Blvd., Tigard OR 97223 503.639.4171 Parcel: 2S101 BC00900 Jurisdiction: Tigard Site address: 12291 SW KNOLL DR Subdivision: Lot: 0 Project: The Knoll at Tigard Project Description: Mechanical for new MF 48 unit housing structure. Owner: FEES THE KNOLL AT TIARD Description Date Amount PO BOX 23206 TIGARD, OR 97281-3206 Permit Fee 06/23/2010 $3,484.71 Plan Review 06/23/2010 $871.18 PHONE: 503 - 293 -4038 12% State Surcharge - Mechanical 06/23/2010 $418.17 Contractor: JACOBS HEATING & AIR CONDITIONING 4474 SE MILWAUKIE PORTLAND, OR 97202 PHONE: 503 - 234 -7331 FAX: 503 -808 -9108 Type of Use: MF Class of Work: NEW Type of Const: VA Occupancy Grp: R -2 Occupancy Load: Stories: 4 Fuel Air Handlers Fuel Types: Units < 10000 cfm: 7 Gas Pressue: Units > 10000 cfm: Furnaces Boilers & Compressors Furnaces < 100K BTU: 0 -3 HP: Furnaces >= 100K BTU: 3 -15 HP: Floor Furnaces: 15 -30 HP: Unit Heaters: 30 -50 HP: Vents w/o Appliances: 50 or Greater HP: Air Conditioning: 3 Heat Pump: 47 Appliances Vent Fans: 58 Vent Systems: Total $4,774.06 Hoods: Comm Incinerators: Woodstoves: Gas Fireplaces: Required Items and Reports (Conditions) Clothes Dryers: 3 Other Mech Units: Gas Outlets: Other Desc: Duct Work: Fire /Smoke Dampers: 11 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952 - 001 -0010 through OAR 952 - 001 -0100. You may obtain a copy of the rules or direct questions to • NC by calling 503.246.6699 or 1.800.33_ • • Issued / Permittee Signature: ^ /VIA OW Call 50 .639.4175 by 7:00 a.m. for an inspection that business day. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. 04/23/2010 09:39 5038099108 JACOBS HEATING PAGE 01/01 g and � 7 '"� f 4 �`"'�'��'k�"�rt`!"p�n ��4 ii111 '� 4 4�n��, , { „,� y � .� d7r. CC ICI I<CSI het` ®a�.�ppi1C' if �I � � � Ni 1;ia'I. (11 1 UI la�l � , a ! u..iFi�Flwmwtit rhtlu mr .n. ix'; : t.., ,�', _aS ___T'r y �d^t" SO,',.,,1'. ,,. City O + )1' Reoavad , 13 12 SW Tali Blvd . Tigard. OR 97 naterl3 oZ3 /d 41 - ►� / % I / i - it ' Plrrmc: 503.639,4 t71 Fax: 503.59849t4 2 3 2010 Plan Rai Daft/By 4s �3 0 (7 other Permit: 4C t P o /Q _ D CO �' LI, iitm Li. 503,639.417; 1' h , 11 Int ern et Lim. www.tigard- or.gov CITY OF TIGARD Nafrod/Metn d: p • ' 0 , -7 6- Supplemental Infbrmaiion 1 ► 1 1► Cs ! t ' . 1 0 • [ v . ytr � ,. ..- Y ff,,,, � , .. t �'y,�• - ✓iT"vy„ry .H ?Y .� �'`t {d� i� T r n � rx:s�• nF 4 5:. :4 '+ ,;t Y iq fyl i.,,,�b• ( 1�Y ksl X16 . fr 1 a ' .• ! 4 E ,^t jr14 ra In Yf 1 ] 1 M 41,•4` If:t . a Er _ .. i3 .1 ... _ 4. n _. ., �.Or'.•IS .. 1:. v . tv�,4u 7I Yv.JI , +- i.!��� r a h.. .' � !�rrt� ."r M . *..r ."'m+kR. �"l''"�l'' �' " I � a .'f' iY'?�S•� ... _ .,a 0 0 New construetioa Mechuniotd permit fees* are Fused cm the value of the work Addition/alteration/replacement. performed_ Indicate the value (rounded to the nearest dollar) of all U Demolition 11 Other: mechanical materials, equipment, labor, overhead, and profit ' Y o- , 2 ., „ , ... • : ,,° 4 • , ti , 0, w " S l• � I } Y . �, Value OJ ti A # s 31( %yy�� im , u t xp, rJe A i ^ n iR ss M i� u 4 i r u a� $ 1 .tsl 17 Vi rc .oat �Lii .4.0il + ,v1K+17:ozzv ere , 14,4 i;fi .g. % J ... " '.1" N '"n' ( ;:li '} nnew :.'�'T1 n' ' 0 ``^,�(1.4:3nr¢ ) Y .b'?� .'il .nv..,.• i ❑ 1- and 2- Family dwelling I Commercial/industrial [] Accessory building For special information use checklist LI Multi - family (] Master builder (] Outer; ` Description Qty. Es. Total tir. 1:4, 4 i 6 �. L .r, 1,,;j n S M [; 4,. 0. n�:, " ,. ,..'' AS°rc"F.Z6.l,t.�"'�ri':`r. 1 ;e tf �, Hest i. , coohn _ Job site address: / a s 9 / S I n LL b/ Air conditioning .! % /' • ores site . lam showin _• laccmemt 1111 46 -75 IIIII City/State/ZIP: l 0 , 4 di a► * • -- Furnace 100.000 BTU ductatvcnte) Ill. 46 -75 • Furnace ]00000 *BTU ducts/vents 54.91 Suite/bldg. /apt. no.: Project name :��� Ir ctA...71"1 • . Hest pump Il 61.06 Cross street/directions to job site: T1+0 k� 0 t- L Duet work 23.32 Hydronic hot water system 2332 - -.. _ .. ... Residential broiler (radiator of h • • ;c) 23.32 - Unit heaters (fuel -type. not electric). in-wall in -duct, svapcndcd etc. 46.75 Flu /vent for any of above 23,32 Subdivision: I Lot no.: Atha: 23.32 Tax map /parcel no.: h 5 Other thei appliances 1 ,u�,4tf r` ' 4 : 40 . +/ } , + o 'A' \i } ';' � i. ;:4.Q ' Water heater 23.32 ti,: c .14 - ..,+4ikH, . n ;.1411%,4,4 , .*.. ✓ ,��' • d ew tR!c''h14 •40 . uS... .Tied.,.:; 4X,0 u r, Gas 5 ,.lace IMO 33.39 r` !', a et- .., ti 11111 flue vent for water heater or pa fireplace 23.32 r,og lighter (gas) 23.32 W • . tlet stove 33.39 Wood fircplacc/inscrt 23.32 Chime lliarr /flue/vent 4 '4 . :4:i y '' n : v'•� Mfr ? 7114Z+34 e (: r,`r raj' � � +,^yr ..v e 23.. 2 . `1�& , aanach +rr t. u�45:,� "s �4b`, fits Otis Other: 23.32 EnvlronmentaI exhaust and ventilation Eggiiiiill 33.39 City/State/ZIP: Clothes dryer exhaust 33.39 Single-duct exhaust (bathrooms, mom. ( ) fax: ( ) toilet corn •. • cars, utiii 1O0MS 23.32 �, d' . 4'd 51 n '3' a ,, ..i * AA',.;,.....;.; r Y 'g� l On" i E n . ' i r 3 TI „ pM1 x'.m : I �7 r .`•. Attic/crawl ..: ce fans _MI� t, .. e .- ' s ,`.?. a: ' yl -, r?; ses.eso+riiMr so..ka..egrC.4 1! • 71� r F the : 23.32 Fact y , _ Contact name: ( s1 r IP. a $14.15 for first four S4.03 for cach additional A�,hess: 1 • At 1 ^,`' e _� l a heat coo. _� City /State/ZIP: w � . J / V i.a o Gas heat • , . • oi el p Wanin • ., • edhmit heater Ph !t ''j ) n j _ f t' . l f 5 � 1 Fame : ( ) Water hcntcr __ - Min E -tail: ` - ' Fireplace . .,,, .. 's, (h cip.t,T!w Pi °SiF,'11%f""tt s ' MINI r a.,,!!�ar S .�1 ���,,�Ay, +� iu s ' � Barbecue � • .Ka; 1 *,:f*5,'Al. r vaaA .. • .hhgh,i' . _ 7dp iii e 4 .G,o`i.A.41,ii: ;:yo ' .iiY i iAi6,,,".. ti Barbecue __ -_�_ Clothes is er 5 Business name: I,. y Rib m ft. r s I. a- te C, Other: 111111 M „FP 1� +1[ $ r p 7 -A A. s: . 1 `.4 k 11. I it / to i ,fiJitro`?t !r�* a - 43n; , s.« q ,,,, , o 7,,,, Yt4,,. City /State/ZIP: 1 i' , r .` Q i n.g, � Subtotal Wi j � Phone b.=j Fax: -f . • / v �D . �FJ� Plan permit O fee) I CCB lie.: 1 [-f L. L ti `, b D State surcharge (12% of permit fee) MEM TOTAL PERMIT FEE 1 a ,. k Authorized signature: ` / 4 / Vii, . / '' This Pew suppuration expires If er is a permit not obtain . "NAM 180 days :atm it has been accepted as complete. t • CEIIE1 APR 2 3 2010 CITY OF TIGARD BUILDING DIVISION Form 4a Project Name: The Knoll at Tigard Page: 1 SYSTEMS - GENERAL Applicability Plans /Specs Discussion of qualifying exceptions Show compliance by including a drawing sheet, detail number, on page 4 -25 specification section and subparagraph. 1. Applicablity (Section 1317) Is this form required? O Form Required. Complete form If a new HVAC system is being installed, or components of an existing HVAC system are being replaced (Le., equipment, controls, ductwork, and insulation.) ❑ Exception. The building or part of the building qualifies for an exception from HVAC code requirements. Applicable code exception is Section 1317.1. Portions of the building that qualify: Area: Exception ❑ -1 ❑ - ❑ - Area: Exception ❑ -1 ❑ - ❑ -3 Area: Exception ❑ -1 ❑ -2 ❑ -3 ❑ Form Not Required. This project does not contain work required to comply with code. 2. Simple or Complex Systems (Section 1317.9 or 1317.10) O Simple System. Building contains only Simple HVAC System(s). Complete this form (4a) and equipment efficiency worksheets as required. Form 4b is not required. ❑ Complex System. Project includes a Complex System. Complete this form (4a), form 4b and equipment efficiency • worksheets as required. 3. Equipment Performance (Section 1317.5) ❑ No New HVAC Equipment. The building plans do not call for new electrical HVAC equipment, combustion heating equipment, or heat - operated cooling equipment. O Complies. All new HVAC equipment have efficiencies not Tess than those required by code. The following equipment efficiency worksheets are attached: ❑ -4a ❑ -4b ❑ -4c ❑ -4d ❑ -4e ❑ -4f ❑ -4g ❑ -4h ❑ -41 ❑ -4j 4. Duct Insulation and Sealing (Sections 1317.7 & 1317.8) ❑ No Ducts. The building plans and specifications do not call for new HVAC ducts or plenums. Ci Complies. The plans and specifications call for all air - handling ducts and plenums to be insulated and sealed as required by Sections 1317.7 &1317.8. 5. Distribution Transformers (Section 1316.1) El No Distribution Transformers. The plans /specs do not call for new distribution transformers. ❑ Complies. All new distribution transformers comply with efficiency, testing, and labeling requirements of Section 1316.1.1. ❑ Exception. The project qualifies for an exception per Section 1316.1.1, Exceptiion: 0 - 0 - 0 0 ❑ - s 0 0 0 0 0 0 0 0 0 Attach relevant documentation for appropriate exception. The plans /specs show compliance in the following ' • .- locations: 4 -1 Compliance with OSSC, effective 04/01/07 Form 4a Project Name: The Knoll at Tigard Page: 2 SYSTEMS - GENERAL ) i 6. HVAC Controls (Section 1317.4) 6.1 System Thermostat /Zone Controls (Section 1317.4.1) O Complies. All new HVAC systems include at least one temperature control device responding to temperatures within the zones. ❑ Exception. HVAC system qualifies for an exception from zone control requirements. The applicable code exception is Section 1317.4.2, Exception ❑ -1 ❑ -2 Portions of the building that qualify: The plans /specs show compliance in the following locations: Mech. Specs 6.2 Off - hour Controls - Auto Setback or Shutdown (Section 1317.4.3) Cl Complies. Systems must have at least one of the following features: ❑ Control Setback Complies. Each system is equipped with automatic control capable of reducing energy through control setback during periods of non -use or alternate use of spaces served. O Equipment Shutdown Complies. Each system is equipped with controls capable of reducing energy use through automatic shutdown during periods of non -use or alternate use of spaces. HVAC systems with equipment shutdown are equipped with at least one of the following: El Programmable controls (1317.4.3.1 (1)) ❑ Occupant sensor (1317.4.3.1 (2)) ❑ Interlocked to a security system (1317.4.3.1 (3)) ❑ Manually activated timers with 2 -hour operation max (1317.4.3.1 (4)) ❑ Exception. The building qualifies for an exception to the requirement for automatic setback or shutdown controls. The applicable code exception is Section 1317.4.3 Exception ❑ -1 ❑ - 2 The plans /specs show compliance in the following locations: Mech Specs 6.3 Control Capabilities (Sec. 1317.4.2.1) O Complies. Zone thermostats are capable of being set to the temperatures described in Sec. 1317.4.2.1. Where used to control both heating and cooling, zone controls shall be capable of providing a temperature range or deadband of at least 5 degrees F within which the supply of heating and cooling energy to the zone is shut off or reduced to a minimum. ❑ Exception. The building qualifies for an exception to the deadband requirements. The applicable code exception is Section 1317.4.2.1 Exception ❑ -t 0 -2 Portions of the building that qualify: The plans /specs show compliance in the following locations: Mech Specs 6.4 Optimum Start Controls (Section 1317.4.3.2) O Complies. Separate HVAC systems have controls capable of varying start-up time of system to just meet temperature set point at time of occupancy. ❑ Exception. HVAC systems have a design supply air capacity not exceeding 10,000 cfm. The plans /specs show compliance in the following locations: Mech Specs 6.5 Heat Pump Controls (Section 1317.4.4) ❑ No Heat Pump. The plans /specs do not call for a new heat pump O Complies. AO new heat pumps equipped with supplementary heaters are controlled to minimize the use of supplemental heat as defined in Section 1317.4.4. The plans /specs show compliance in the following locations: Mech Spec 4 -2 Compliance with OSSC, effective 04 /01/07 Form 4a Project Name: The Knoll at Tigard Page: 3 SYSTEMS - GENERAL 7. Economizer Cooling (Section 1317.3) ❑ No Cooling. The building plans do not call for a new fan system with mechanical cooling. ❑ Complies. Each new fan system has an air economizer capable of modulating outside -air and return -air dampers to provide up to 100 percent of the design supply air as outside air. 0 Exception At least one new fan system qualifies for an exception. The applicable code exception is Section 1317.3, Exception ❑ -1 ❑ -z O -3 0.4 O -s ❑ -a ❑ -7 If Exception 3 is selected complete the following: (a) Total cooling capacity of exempt units (Btu/hr) 132000 (b) Total installed building cooling capacity (Btu /hr) 132,000 l Complies. Sum of exempt units rated at less than 54,000 Btu/hr is <240,000 Btu/hr or a/b < 0.10 (10% of total building cooling capacity). Unit Identifier of exempt units: FCU-, 2, 3 and 4 The plans /specs show compliance in the following locations: M100 8. Economizer Pressure Relief & Integration (Section 1317.3.1 and 1317.3.2) O No Economizers Required. Project does not contain a new fan system requiring economizers. O Overpressurizatlon Complies. The drawings specifically identify a pressure relief mechanism for each fan system that will relieve the extra air introduced by the economizer. ❑ Integration Complies. Economizer is capable of providing partial cooling even when additional mechanical cooling is required to meet the remainder of the cooling load. o Exception. The applicable exception is Section 1317.3.2, Exception ❑ -t ❑ - The plans /specs show compliance in the following locations: 9. Hot Gas Bypass (Section 1317.5) O No Hot Gas Bypass O Complies. See allowable amount of hot gas bypass as a percentage of total cooling capacity in table below. Unit ID Rated Cooling Capacity ::'`' ' Hot Gas Bypass Capacity Allowable Hot Gas Bypass Rated Cooling Capacity Max Hot Gas Bypass Capacity :: ria 9 p tY yp p tY >� <240,000 Btu /hr 50% >240,000 Btu /hr 25% ❑ Exception. Unitary packaged system with cooling capacity no greater than 90,000 Btu/h 4 -3 Compliance with OSSC, effective 04/01/07 Form 4a Project Name: The Knoll at Tigard Page: 5 SYSTEMS - GENERAL 13. High Occupancy Ventilation (Section 1317.2.2) ❑ Complies. HVAC systems with ventilation air capacities of 1,500 CFM or greater that serve areas having an average occupant Toad of 20 square feet per person or less from Table 1004.1.2 have a means to automatically reduce outside air intake. Identify applicable systems: Plans /specs indicate where equipment (Le. carbon dioxide sensor) and sequence is specified: ❑ Exception. HVAC systems are equipped with an energy recovery device with at least 50% recovery effectiveness. GI No High Occupancy Systems. Project does not contain an HVAC system as described above. 14. Exhaust Air Heat Recovery (Section 1318.3) 2 Not Regulated. HVAC system does not have: 1) design supply air cap. of >10,000 cfm, and 2) min. outside air supply >70 %, and 3) at least 1 exhaust fan rated at 75% of min outside air supply. ❑ Complies. Heat recovery system increases outside air temperature by 20 °F (Climte Zone 1) or 30 °F (Zone 2) and has provision to provide bypass during air economizer mode. ❑ Exception. An HVAC system qualifies for an exception to this requirement. Applicable exception from Section 1318.3 Exception 0 -1 0 -2 0 -3 ❑ -4 0 -5 0 -6 0 -7 The plans /specs show compliance in the following locations: 15. Large Volume Fan Systems (Section 1318.4.2.4) O Not Regulated. The building plans or specifications do not call for fan systems over 15,000 CFM that serve a single zone and function for the purpose of temperature control. ❑ Complies. Fan systems are equipped with variable frequency drive or two speed motor to reduce airflow as required by Section 1318.4.2.3. The plans /specs show compliance in the following locations: 16. Variable Speed Drives (Section 1317.10.3.1) O Not Regulated. The building plans or specifications do not call for fan and pump motors 10 horsepower and greater that serve variable -flow air or liquid systems. ❑ Complies. All fan and pump motors 10 hp and greater which serve variable -flow air or liquid systems are controlled by a variable -speed drive. ❑ Exception. The building qualifies for an exception to the variable -speed drive requirement. Portions of the building that qualify: Applicable code exception is Section 1317.10.3.1, Exception The plans /specs show compliance in the following locations: 17. Service Water Heating (Sec. 1315) ❑ No New Water Heating. The building plans and specifications do not call for new water heaters, hot water storage tanks or service hot water distribution systems. O Complies. All new water heaters, hot water storage tanks or service hot water distribution systems comply with the requirements of the Section 1315. ❑ Exception. The applicable code exception is Section: Exception: 4 .4 ...T1 �� /� Portions of the building that qualify: The plans /specs show compliance in the following locations: 4 -5 Compliance vrith OSSC, effective 04 /01/07 Form 4a Project Name: The knoll at Tigard Page: 6 SYSTEMS - GENERAL 18. Swimming Pools, Spas and Hot Tubs (Section 1315.5) CI No New Pools. The building plans and specifications do not call for new, swimming pools, spas or hot tubs. ❑ On /Off Controls Complies. Spa and hot tub heaters are equipped with a readily accessible ON /OFF switch as required by Section 1315.5.1. ❑ Ventilation Controls Complies. Pool ventilation system is controlled based on humidity. ❑ Cover Complies. All heated pools, hot tubs and spas are equipped with a cover. ❑ Heat Recovery Complies. Pools, Spas, and hot tubs, over 200 ft utilize recovered heat as required by Section 1315.5.3. ❑ Exception. Heat recovery is not necessary as pool is heated by renewable energy or waste heat recovery sources capable of providing at least 70 percent of the heating energy required over an operating season. 19. Fume Hoods (Section 1317.2.1.) O No Fume Hoods. The building plans do not call for fume hood systems that have a total exhaust rate greater than 15,000 cfm. ❑ Complies. Fume hood systems have at least one of the following features: ❑ Variable air volume hood exhaust and room supply systems capable of reducing exhaust and makeup air volume to 50% or less of design values. ❑ Direct makeup (auxiliary) air supply equal to at least 75% of the exhaust rate, heated no warmer than 2° F below room set point, cooled no cooler than 3° F above room set point, no humidification added, and no simultaneous heating and cooling used for dehumidification control. ❑ Heat recovery systems to precondition makeup air from fume hood exhaust in accordance with 1318.3 - Exhaust Air Energy Recovery, without using any exception. The plans /specs show compliance in the following locations: 20. Parking Garage Ventilation (Section 1317.2.3) O No Enclosed Garages. The building plans and specifications do not call for enclosed Group S -2 parking garages with a ventilation exhaust rate greater than 30,000 CFM. ❑ Complies. The plans and specifications call for carbon monoxide sensing devices as required by Section 1317.2.3. ❑ Exception. Open parking garages. 21. Kitchen Hoods (Section 1317.11) O Not Regulated. The plans /specs do not call for any new kitchen hoods with exhaust capacity greater than 5,000 cfm each. ❑ Complies. All new kitchen hoods with a total exhaust capacity greater than 5,000 cfm have at least 50 percent of the required makeup air; (a) unheated or heated to no more than 60 °F; and (b) uncooled or evaporatively cooled. a The plans /specs show compliance in the following locations: de 22. Outside Heating Systems (Section 1317.12) O No Outside Heating Systems. The plans /specs do not call for new permanently installed heating systems outside the building. ❑ Complies. All new permanently installed outside heating systems are radiant gas fired systems controlled by an occupancy sensor or timer switch as required by Section 1317.12. 4 -6 Compliance with OSSC, effective 04/01/07 Worksheet 4a Project Name: The Knoll at Tigard Page: _7 UNITARY AIR CONDITIONER - AIR COOLED Equipment .... (a) (b) (c) (d) Proposed (e) (0 Performance Discussion of equipment ratings Cooling Capacity Seasonal or Part Compliance New or andequtpmentdesnitions on page Equip. ID . • . - • Model Designation (0tulh) Steady State Load Schedule (A -E) Replacemnt9' CU -1 Ductless Split System 24000 17 B New CU -5 Ductless Split System 18000 15 B New CU.6 Ductless Split System 18000 15 B New Required Indicate source of Information Document - ation ❑ ARI Unitary Directory, Section AC, page: ❑ ARI Applied Products directory, Section ULE, page: O Product data (Attach data banished by the equipment supplier, I.e., "cut sheets") Code Required Cooling CaEacity (btu hr) Minimum Rating Efficiencies Compliance Seasonal or Part Schedule Equipment Type Over , But not over - Steady State _, Load New • 0 65,000 na 13 SEER Single Package Without a Healing • Replacement * 0 65,000 na 9.7 SEER A Section or With Electric Resistance 65,000 135,000 10.3 EER Na This schedule of equipment Heat pal 135,000 240,000 9.7 EER Na effictenctes was reformatted 240,000 7 • 9.5 EER 9.7 IPLV • from code, Table 13 -L 760,000 .. .. - 9.2 EER 9.4 IPLV New • 0 - 65,000 na 13 SEER Split System Without a Heating Replacement • 0 - 65,000 na 10 SEER e Section or With Electric Resistance 65,000 135,000 10.3 EER Na Neat All 135,000 240,000 9.7 EER Na 240,000 760,000 9.5 EER 9.5 IPLV 760,000 - 9.2 EER 9.2 IPLV New • 0 65,000 na 13 SEER Single Package.Witha Healing Replacement' 0 65,000 na 9.7 SEER C Section Other Than Electric 135,000 10.1 EER Na Resistance All • 135,000: 240,000 9.5 EER Na • 240,000 • - 760,000 9.3 EER 9.5 IPLV 760,000 , 9.0 EER 9.2 IPLV: _ 7 _ New • • 0 65,000 - na 13 SEER { - eA Replacement' 0 65,000 na 10 SEER tr w D Split System With a Heating Section • 65,000 .135,000 10.1 EER Na Other Than Electric Resistance . All • 135,000 240,000 9.5 EER Ma 240,000 760,000 9.3 EER 9.7IPLV 760,000 - 9.0 EER 9.41PLV E Condensing Unit Oniy All - • 135,000 - 10.1 EER 11.2 IPLV ' Equipment Is a new installation or replaces existing equipment 4-11 Compliance with OSSC, effective 04/01/07 Worksheet 4c Project Name: The Knoll at Tigard Page: 8 UNITARY HEAT PUMP - AIR COOLED Equipment (a) - (b) (c) .. (d) (e) . (f) (9) Proposed Rating Proposed Heating Rating Dscussion of equp -nest ratings and equ� meet Cooling .. .. Compliance definitions on page 4 -19. Capacity COP Schedule New or Equip. ID Model Designation (Btulh) SEER EER HSPF COP (47 °F) (17°F) (A -E) Replacmnt' HP -1 Split System 24000 14 3.72 2.6 B New HP -2 Split System 24000 13 3.72 2.6 B New HP -3 Split System 42000 14 3.7 2.56 B New HP -4 Spilt System 42000 14 3.7 2.56 B New Required Indicate source of Information Document- ❑ ARI Unitary Directory, Section AC, page: ation ❑ ARI Applied Products directory, Section ULE, Page: O Product data (Attach data furnished by the equipment supplier, Le., 'cut sheets') Code Required - Cooling Capacity - . Efficiencies (blurhr) Minimum Cooling Rating Minimum Healt . Rating Compliance But not Seasonal or COP COP Schedule Equipment Type _ Over over EER Part Load HSPF (© 47°F1 (g) 17° F) New 0 65,000 - 13 SEER 7.7 - - • Single Package Without a Healing Repkmnt' 0 65,000 - 9.7 SEER 6.8 - - A Section or With Electric 65,000 135,000 10.1 nla - 32 2.2 This schedule of - Resistance Heat equ'pmentet0Uencies All 135,000 240,000 9.3 n/a - 3.1 2,0 was reformat-ted from 240,000 - - - 9.0 9.2 IPLV - 3.1 2.0 the code, Tab's 13-M. ... _ _ . ' New 0 65,000 - 13 SEER 71 SO System Wltiwut a Heating Replcmnt• 0 65,000 - 10 SEER 6.8 - - B Section or With Electric 65.000 135,000. 10.1 : nla - 3.2 22 Resistance Heat A$ 135,000 240,000 9.3 rife - 3.1 2.0 240.000 - 9.0 9.2 IPLV - 3.1 2.0 New 0 65,000 - 13 SEER 7.7 - - Single Package With a Heating Reptaimr 0 65,000 - 9.7 SEER 6.6 - C Section Other Than Electric 65,000 135,000 9.9 nla - 3.2 22 Resistance AS 135,000 240.000 9.1 nla - 3.1 2.0 - t K'�l •:d 240000 8.8 9.O IPLV - 3- 2 . 0 - r {rtn y Neer' 0 65,000 13 SEER 7.7 ' Split System With a Healing • Repkmnt 0 65,000 - 10 SEER 6.8 - - y'' D Section Other Than Electric 65,000 135,000 9.9 n/a 3.2 2.2 Resistance Ali 135,000 240,000 9.1 ii/a - 3.1 2.0 - 240.000 - 8.8 9.01PLV - 3.1 2.0 Equipment is new installation or replaces erdsting equipment 4.13 Compance with CSSC, etfec6ve 04/01/07 Worksheet 4f Project Name: The Knoll at Tigard Page: 9 PACKAGED TERMINAL HEAT PUMP - AIR COOLED Equipment . (a) . (b) (c) (d) (e) Proposed Code Minimum Enter the cooling capacity in column (c). If capacity Is less Cooling Cooling than 7,000 Btu/11r, use 7,000. If Rating Heating -Rating Heating • above 15,000, use 15,000. Cooing Calculate the code minimum Capacity EER EER CaR's from t a code below Type of Equipment Equip. ID Model Designation (Btu/hr) (95 F db) (95 F db) using cooling capacdy In the PTHP -1 Through Wall Packaged 8,900 11.5 3.2 10.4 3.0 column (c). Enter results In column (e). - PTHP -2 Through Wall Packaged 11,800 10.8 3.1 9.8 2.9 • Discussion of equipment PTHP -3 Through Wail Packaged 13,900 9.3 2.9 9.3 2.8 ratings and equipment defutllons on page 4 -19. Units Installed in New Construction Replacement of Existing Units (Installed prior to 10/01103) Required Indicate source of Information Document- 0 ARI Unitary Directory, Section AC, page: ation 0 ARI Applied Products directory, Section ULE, Page: Q Product data (Attach data furnished by the equipment supplier, Le., "cut sheets") ■ Calculate the code minimum EERs and COP's from the formulas below using the cooling capacity in column (c). Code Required Enter the results h column (e). Efficiencies New Construction EER: EER ® 95F Test Conditions = 12.3-(0.213x Cap/1000) New Construction COP: COP = 3.2 - (0.026 x Cap/1000) Replacement Units EER: EER @ 95F Test Conditions = 10.8-{0.213x Cap /1000) Replacement Units COP COP - 2.9 - (0.026 x Cap /1000) 4 - 16 Compliance with OSSC, effective 04/01/07