Specifications City of Tigard, Oregon • 13125 SW Hall Blvd. • Tigard, OR 97223 November 3, 2006 bid J 476 ®i CA) ,.5 l Cascade Fire Protection Co. David Davies 24023 NE Shea Ln #110 Wood Village, OR 97060 RE: FIRE SPRINKLER SYSTEM MODIFICATION - REVIEW Project Information Building Permit: BUP2006 -00504 Construction Type: 5 -B Tenant Name: Avalon Hair Salon Occupancy Type: B Address: 14350 SW Barrows Rd #001 Stories: 1, Hazard: Light 1,505 sq ft area The plan review was performed under the State of Oregon Structural Specialty Code (OSSC) 2004 edition, Oregon Fire Code 2004 edition, and NFPA 13. The submitted plans are approved subject to the following. TESTING - Section 16.2.1 1. Hydrostatic testing of the system shall occur at sprinkler final. The contractor's material and test certificate required by NFPA 13, 16.1 shall be completed and signed by both the installer and building owner. 2. Unless permitted by 16.2.1.2 through 16.2.1.6, all piping and attached appurtenances subjected to system working pressure shall be hydrostatically tested at 200 psi (13.8 bar) and shall maintain that pressure without loss for 2 hours. Loss shall be determined by a drop in gauge pressure or visual leakage. The test pressure shall be read from a gauge located at the low elevation point of the system or portion being tested. *16.2.1.4: Modifications affecting 20 or fewer sprinklers shall not require testing in excess of system working pressure. WATER FLOW ALARMS: - Section 6.9.1 3. Water flow alarm apparatus shall be listed for the service and so constructed and installed that any flow of water from a sprinkler system equal to or greater than that from a single automatic sprinkler of the smallest orifice size installed on the system will result in an audible alarm on the premises within 5 minutes after such flow begins and until such flow stops. SPRINKLER SYSTEM MONITORING: OSSC 901.6. - NFPA 13 sec 8.16 4. All valves controlling the water supply for automatic sprinkler systems and water -flow switches on all sprinkler systems shall be electrically monitored where the number of sprinklers are more than 20. HANGERS: NFPA 13 sec 9.2 5. The maximum distance between hangers shall not exceed that specified in Table 9 -2.2. Phone: 503.639.4171 • Fax: 503.684.7297 • www.tigard- or.gov • TTY Relay: 503.684.2772 6. The maximum distance between hangers for listed nonmetallic pipe shall be modified as specified in the individual product listings. SWAY BRACING: - Section 9.3.5 - 9.3.5.8 7. The system piping shall be braced to resist both lateral and longitudinal horizontal seismic loads and to prevent vertical motion resulting from seismic loads. The structural components to which bracing is attached shall be determined to be capable of carrying the added applied seismic loads. Sway braces shall be designed to withstand forces in tension and compression. Bracing shall be attached directly to feed and cross mains. RESTRAINT OF BRANCH LINES. - Section 9.3.6 8. Restraint is considered a lesser degree of resisting loads than bracing and shall be provided by use of one of the following. (1) A listed sway brace assembly (2) A wraparound U -hook satisfying the requirements of 6- 4.5.3, Exception Number 3 (3) No. 12, 440 -1b (200 -kg) wire installed at least 45 degrees from the vertical plane and anchored on both sides of the pipe (4)Other approved means 9. Wire used for restraint shall be located within 2 ft (610 mm) of a hanger. The hanger closest to a wire restraint shall be of a type that resists upward movement of a branch line. The end sprinkler on a line shall be restrained against excessive vertical and lateral movement. Where upward or lateral movement would result in an impact against the building structure, equipment, or finish materials, branch lines shall be restrained at intervals not exceeding 30 ft (9 m) PIPING CLEARANCE: - Section 9.3.4 10. Where pipe passes through holes in platforms, foundations, walls, or floors, the holes shall be sized such that the diameter of the holes is 2 in. (50 mm) larger than the pipe for 1 in. (25 mm) nominal to 3 ' /z" (89 mm) nominal and 4 in. (100 mm) larger than the pipe for pipe 4 in. (100 mm) nominal and larger. Clearance from structural members not penetrated or used, collectively or independently, to support the piping shall be at least 2 in. SPARE SPRINKLERS: - Section 6.2.9 11. The stock of spare sprinklers shall include all types and ratings installed and shall be as follows: a. For systems having less than 300 sprinklers, not fewer than six sprinklers Approved Plans: 1 set of approved plans, bearing the City of Tigard approval stamp, shall be maintained on the jobsite. The plans shall be available to the Building Division inspectors throughout all phases of construction. 106.3.1 OSSC When submitting revised drawings or additional information, please attach a copy of the enclosed City of Tigard, Letter of Transmittal. The letter of transmittal assists the City of Tigard in tracking and processing the documents. Respectfully, Val Henzel, Senior Plans Examiner our ,f (DCD SGT CASCAbE FIRE PROTECTION CO. 24023 N.E. SHEA LANE SUITE #110 WOOD VILLAGE, OREGON 97060 PH: 503 - 491 -8755 FAX: 503- 491 -8768 E -mail: cascade22 @verizon.net , z , 6 c . .I '.' .I lVU1 FIRE SPRINKLER SUBMITTAL PACKAGE 4 - FOR AVALON HAIR SALON 14350 SW BARROWS ROAD TIGARD, OREGON CFPCO JOB #9045 ;4 CASCADE FIRE PROTECTION CO 24023 N.E. SHEA LANE SUITE #110 WOOD VILLAGE, OREGON 97060 PH: 503- 491 -8755 FAX: 503- 491 -8768 email: cascade22 @verizon.net SUBMITTAL INDEX FOR AVALON HAIR SALON 14350 SW A RO S ROAD ,.;,. TIGARD OR re CASCADE FIRE PROTECTIOM JOB # 9045 ❑ SPRINKLER PIPE: Dyna Thread - Threaded, 1" -2" Pipe ❑ PIPE FITTINGS: Grinnell- Figure 40 -5 Mechanical Tee Ward- Threaded Fittings, 1 " -2" ❑ PIPE HANGING MATERIALS: Tolco -All Thread Rod, 3/8" Tolco - Adjustible Band Hanger, 1" HangerMate Anchors ❑ FIRE SPRINKLERS: Tyco- TY3251, TY -B, K5.6, 1/2 ", 155 °, Chrome SSP ❑ FIRE SPRINKLER PLAN u Z ' Full Line Sch4O Replacement Dyna- Thread® offers the life expectancy of Sch40 with superior hydraulics and greater value. Dyna- Thread sprinkler pipe represents an engineering advancement for the sprinkler pipe industry. It combines the safety and longevity of traditional Sch -40 pipe with quality and superior hydraulic advantages. Comparison to Schedule 40 Comparison to'`L W T'Pipes �7 1 • Dyna- Thread's inside diameter is up • With its increased strength and lighter • More wall thickness at the thread to 3.6% larger than Sch -40 giving it weight, Dyna- Thread reduces (CRR =1.00) gives Dyna- Thread superior hydraulics. And, when used installation fatigue and is ideal for better life expectancy than lightwall in combination with Dyna -Flow pipe, retro -fit applications. threadable pipe joints. down sizing often occurs. Corrosion Resistance Ratio (CRR) is a • Unlike lightwall threadable pipe, • Dyna- Thread is fully listed and UL (Underwriters Laboratory) term for Dyna- Thread has no thread gauge approved by UL, ULC, and FM for the estimated life expectancy of a pipe warning. fire sprinkler applications. joint. This is based on the calculated • Dyna- Thread is approved for • The life expectancy of Dyna - Thread wall thickness at the base of the first standard hanger spacing (15 ft. equal based on the exposed thread, assumed to be the and Sch -40 are a q weakest point of the pipe length. Dyna- O.C.), can be used as earthquake calculated wall thicknesses per UL. sway bracing, and is safe to use as Thread and Sch -40 have the same °' • The consistent quality of steel used to calculated wall thicknesses at this point drops. make Dyna- Thread facilitates smooth and are both assigned the same CRR of • Dyna - Thread is safer to weld on. threading and lower maintenance 1.00. costs. • Dyna- Thread is more widely accepted than lightwall threadable • The exterior of Dyna - Thread is The internal surface of all black Allied where Sch -40 is specified. protected by a clean, durable mill Tube & Conduit Fire Sprinkler pipe coating for extended shelf life and products up to 4.5000" in diameter is easy paint application. coated with our new Antibacterial Formula, "ABF ". In scientific laboratory test, ABS proved to have superior Sp n & ecificatios Ap resistance to microbial colonization of (141) ® ® pipe walls, thereby delaying or possibly Super 40/Dyna- Thread pipe is preventing the onset of manufactured to meet: ASTM A -135, Microbiologically Influenced corrosion Grade A and is in compliance with Listed Approved Listed NFPA -13. All sizes of Super 40/Dyna- (MIC) when the First Sprinkler System is first installed. Thread are rated at 300 psi working pressure. Super 40/Dyna- Thread is UL - ,e clf l cat l .. and ULC Listed for wet, dry deluge and g 1 I pre- action sprinkler systems and FM NPS Nominal I.D. Wt. Wt. (H20 Filled) Pcs/ Wt/Lift (21') Wt/Lift (24') Wt/Lift (25') Approved for use in wet systems. Super In; mm In; mm Lbs /Ft; Kg /m Lbs /Ft; Kg /m Lift Lbs; Kg Lbs; Kg Lbs; Kg 40/Dyna Thread can be "hot - dip" _ 1" 1.080 1.330 1.75 70 1955 2234 2327 galvanized to meet FM requirement for 25 27.4 2.0 2.60 70 887 1013 105; dry systems. Super 40/Dyna- Thread is • 1'/<" 1.408 1.870 2.54 51 2002 2288 2384 approved for all threaded couplings and - 32 35.8 2.8 3.78 51 908 1038 108 welded outlets and is suitable for all 1 Y 1.639 2.290 3.22 44 2115 2418 2519 roll - grooved, and plain -end fittings. ' 40 41.6 3.4 4.79 44 959 1097 114 (See listing information). 2" 2.104 3.050 4.57 30 1921 2196 2287 50 53.4 4.5 6.80 30 871 996 103 � 16100 S. Lathrop • Harvey, IL 60426 Customer Service: t�C® /Flow Control \ ®/ allied 11350 Norcom Rd. • Philadelphia, PA 19154 (800) 882 -5543 TUBE & CONDUIT 2525 N. 27 th Ave. • Phoenix, AZ 85009 Fax 708 - 339 -1806 S3 - 3 t"; i ° 1 / F/re & Budding ° Products l i r 4 Customer Service /Sales: Technical Services: Tel: (800) 381 -9312 / Fax: (800) 791 -5500 Tel: (414) 570 -5000 / (800) 558 -5236 www.tyco - fire.com Fax: (414) 570 -5010 / (800) 877 -1295 Grinnell Grooved Fire ' Products Figure 40 -5 Strap G eneral Housing: Ductile iron conforming to Limited ASTM A -536, Grade 65 -45 -12 Description Protective Coatings: Warranty • Clear rust inhibitive coating Products manufactured by Tyco Fire Products are I ' • Zinc electroplated conforming to 4,/ i0 warranted solely to the original Buyer for ten (10) ,, tr Service ASTM B -633, Type III Servi 2 (optional) years against defects in material and workmanship r 4' , -1, U•Bolt: Carbon steel conforming to r `' ` ' when paid f properl in and maintained Vds ''' / , 4 � t � ff ASTM A 307, Grade A, Zinc electroplated under normal use and service. This warranty will q . + , . Nuts: Carbon steel conforming to . ' expire ten (10) years from date of shipment by Tyco -- ' ASTM A -307, Grade A, Zinc electroplated " `T Fire Products. No warranty is given for products or ® Gasket: (specify when ordering) See Fire Protection components manufactured by companies not ® Submittal Sheet for • Grade S EPDM green color code. affiliated by ownership with Tyco FireProductsorfor Pressure Rating and (See Data Sheet TFP1895 for aid in selectin products and components which have been subject Listing /Approval Information proper gasket) to misuse, improper installation, corrosion, orwhich The Figure 40-5 Strap is an economical alternative have not been installed, maintained, modified or to welded pipe outlets on steel pipe. ®B°de��n repaired in accordance with applicable Standards of The Figure 40 -5 Strap may be used with full . rGcedure the National Fire Protection Association (NFPA), lengths of pipe and eliminates threading and and /or the standards of any other Authorities Having welding, decreasing waste and installation time. When placing an order, indicate the full product Jurisdiction. Materials found by Tyco Fire Products The 40 -5 Strap may be used in wet, dry pipe and name. Please specifythe quantity, figure number, to be defective shall be either repaired or replaced, at deluge systems. type of gasket, Grade "E" EPDM, and size. Tyco Fire Products' sole option. Tyco Fire Products WARNING Grinnell Grooved Piping Products, valves, neither assumes, nor authorizes any person to The Figure 40 -5 Strap described herein must be accessories and other products are available assumefor it, any other obligation in connection with installed and maintained in compliance with this throughout the U.S., Canada, and internationally, the sale of products or parts of products. Tyco Fire document, as wellas withtheapplicablestandards through a network of distribution centers. You Productsshallnotberesponsibleforsprinklersystem of the National Fire Protection Association, in may write directly or call 215 - 362 -0700 for the designerrorsorinaccurateorincompleteinformation addition to the standards of any other authorities distributor nearest you. supplied by Buyer or Buyer's representatives. having jurisdiction. Failure to do so may impair IN NO EVENT SHALL TYCO FIRE PRODUCTS BE the performance of this device. , LIABLE, IN CONTRACT, TORT, STRICT LIABILITY The owner is responsible for maintaining their � ��� �� apt OR UNDER ANY OTHER LEGAL THEORY, FOR fire protection system and devices in proper Rilaiintenance INCIDENTAL, INDIRECT, SPECIAL OR operating condition. The installing contractor or CONSEQUENTIALDAMAGES ,INCLUDINGBUTNOT sprinkler manufacturer should be contacted with The owner is responsible for the inspection LIMITED TO LABOR CHARGES, REGARDLESS OF any questions. testing, and maintenance of their fire p rotection WHETHERTYCOFIREPRODUCTSWASINFORMED _ system and devices in accordance with the ABOUT THE POSSIBILITY OF SUCH DAMAGES, Technical applicable standards of the National Fire Protection AND IN NO EVENT SHALL TYCO FIRE PRODUCTS' �l! Association (e.g., NFPA 25), in addition to the LIABILITY EXCEED AN AMOUNT EQUAL TO THE Data standards of any authority having jurisdiction. SALES PRICE. The installing contractor or product manufacturer mE FOREGOING WARRANTY IS MADE /N LIEU OF Figure: 40 -5 should be contacted relative to any questions. ANY AND ALLO7HERWARRANT/ESEXPRESSOR Outlet: Threaded Any impairment must be immediately corrected. IMPLIED. INCLUDING WARRANTIES OF Approvals: UL, FM, ULC, and VdS; It is recommended that automatic sprinkler MERCHANTABILITY AND FITNESS FOR A See Fire Protection Submittal Sheet for exact systems be inspected, tested, and maintained by PARTICULAR PURPOSE. Listing / Approval information. a qualified Inspection Service. Page 1 of 2 September 2004 TFPI 720 Page 2 of 2 TFP1720 Figure 40D5 Strap c Pipe Nominal Dimensions Hole Net 0 Size A B C D Size Wt. © _, Run x Inches Inches Inches Inches Inches Lbs. i= =; Branch mm mm mm mm mm Kg. © !'''�rl°' , 1/2" 2.00 1.50 3.50 1.20 1 3 /16 0.84 =clot- „" A 1 /4" X ��111 a 50.8 38.1 88.9 30.5 30.2 0.4 it 1' /4" x 3/4" 2.00 1.50 3.50 1.20 1 0.88 D 50.8 38.1 88.9 30.5 30.2 0.4 0 % 1'/4" x 1 " 2.31 1.68 3.50 1.20 1 1.13 58.7 42.7 88.9 30.5 30.2 0.5 1 x 1/2" 2.12 1.62 3.50 1.32 1 0.84 Item Description 53.8 41.1 88.9 33.5 30.2 0.4 1 Housing 1'/ x 3/ 2.12 1.62 3.50 1.32 1 0.88 53.8 41.1 88.9 33.5 30.2 0.4 2 Gasket 1 x 1 4 2.43 1.80 3.50 1.32 1 1.13 3 Flanged Nut 61.7 45.7 88.9 33.5 30.2 0.5 4 _ U -Bolt 2 " x '/2 2.36 1.86 3.74 1.55 1 0.88 59.9 47.2 95.0 39.4 30.2 0.4 Fitting Equivalent Length 2 " x 3/ 2.36 1.86 3.74 1.55 1 0.95 Size (1 inch pipe) 59.9 47.2 95.0 39.4 30.2 0.4 1 x 1" 8 2" x 1" 2.67 2.04 3.74 1.55 1 1.16 67.8 51.8 95.0 39.4 30.2 0.5 1 x 1 6 , 2.61 2.11 4.25 1.80 1 0.90 2" x 1" 6 21/2.. x /2" 66.3 53.6 108.0 45.7 30.2 0.4 2 x 1" _ 4 2 x 3/4" 2.61 2.11 4.25 1.80 1 0.99 • The friction loss for these outlets is specified in 66.3 53.6 108.0 45.7 30.2 0.4 equivalent length of 1 inch Schedule 40 (C =120) pipe. 2 x 1" 2.92 2.29 4.25 1.80 1 3 /16 1.21 74.2 _ 58.2 108.0 45.7 30.2 0.5 The 1 inch outlets can be used with a nipple leading Note: Outlet threads conforming to ISO 7 -1 are available, contact directly to a sprinkler. These fittings should be used Tyco Fire Products. for hydraulically calculated systems only. General Notes: It is the Designer's responsibility to select products suitable for the intended service and to ensure .- ISO that pressure ratings and performance data is not exceeded. Always read and understand the installation 9 instructions (IH 1000). Never remove any piping component or correct or modify any piping deficiencies without A first depressurizing and draining the system. Material and gasket selection should be verified to be compatible for the specific application. Certified Company TYCO FIRE PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19946 Printed U.S.A. WARD MANUFACTURING FITTINGS SUBMITTAL CAST IRON FITTINGS The manufacturing process for the Class 125 Cast iron fittings adheres to strict standards to assure superior quality. Tapping for these fittings is done on the most modern types of threading machines. All tapping is done to USA Standards for iron pipe threads. Straightness and correct depth of threads are assured through continuous capable inspection. Precision machining and thread chamfering allows Ward flanged components to be easily installed. These fittings are designed to handle the tough service that flanged components normally experience. Ward cast iron drainage fittings are designed especially for drainage systems using wrought pipe. The inside diameter of the fitting is the same as that of wrought pipe. These fittings are made with an interior shoulder so that when the joint is made, the end of the pipe practically meets the shoulder and forms a continuous surface providing smooth flow of the pipe contents. CAST IRON THREADED FITTINGS SPECIFICATIONS Standard Class 125 Specifications: ANSI B1.20.1, Threads, B 16.4, Dimensions, Pressure Rating ASTM Al26, Material. A153, Galvanizing Federal Spec: WWP 521 Pressure Ratings: 125 psig — Saturated Stream 175 psig — At 150 Degrees W. O. G. Federal Spec: WW -P -501 U.L.C. and U.L. . Listed Where Applicable FM Approved Where Applicable Plug and Bushing Specifications: ANSI B1.20.1, Threads, B16.14, Dimensions, Pressure Rating ASTM A197 (Malleable), Al26 (Cast), Material A153, Galvanizing Pressure Ratings: Malleable: 150 psig — Saturated Stream 300 psig — At 150 Degrees W.O.G. Pressure Ratings: Cast: 125 psig — Saturated Stream 175 psig — At 150 Degrees W.O.G. Federal Spec: WW -P-471 • U.L.C. and U.L. . Listed Where Applicable FM Approved Where Applicable CASE' IRON 45 ELLS 1 BLK CI 45 ELL Ward ID: 2320600003 Mnemonic Code: 1.BC45L A etA r A 8 �' utside Dia. Of1� I; Length of i Center j , - -1 O to End !Take k , -_ r: Unit ! 11' i! Band (min) NPS ;T hread (min) 14 A ,! B , i ii Wei 0.8671bs {i 1 1_12 1 1' 0.95 0.58 1 -1/2 BLK CI 45 ELL Ward ID: 2320800003 Mnemonic Code: 1D.BC45L A 11 tri■ CA Center to r Outside Dia. Of �; j Length of End I Take Band min Thread min I Unit Band ( min NPs ( ) A Ou c � Weight s! 0 .743� 2.68 07 18Ibs 1.43 r 1 /2 2 BLK CI 45 ELL Ward ID: 2320900003 Mnemonic Code: 2.BC45L A # 4 4 rt ✓ C A - g ' Center to I ; O utside Dia. Of _' Length of j; End 1! Take I : Band (min) I i Thread (min) f Unit A ( Out ,�`� B NPS C i. Weight 1 r ' 0.93 '� 3.28 1 2 ��.. 0 75 2 9751bs- 1 CAST IRON STRAIGHT 90 ELLS 1 BLK CI 90 ELL - Ward ID: 2120600003 Mnemonic Code: 1.BCL • A ii II �. � iiCenter toll Thread i ll Outside Dia. Of 1; i l I End I Length (min) Take Out i Band (min) 1 ; Unit j, A D 1 Dimension 1 I B j [NIPS i ' Weight I 1j 1.5 0.58 0 813 ,_ ..�. 1.95 - r 1 11.0421bs i 1 -1/2 BLK CI 90 ELL Ward ID: 2120800003 Mnemonic Code: 1D.BCL r —A 8 Ira _ ir " I dr. D Thread Outside Dia. Of ji " Center to . �! Take Out i End Unit � Length (min) J Dimension / Band (min) I,.NPS il B jlr ---1 -- h A I Weight ,I _. _._____.. - ___ ._.._ ___w F 2 68 _ f, 1/2 I 1 :__ f12 0931bs1 r p 7 1 1 253 2 BLK CI 90 ELL Ward ID: 2120900003 Mnemonic Code: 2.BCL A B - Ilk ---7 i) ' Thread Outside Dia. Of li Center to } 1 i ; Length (min) T Out j Band (min) i End l Unit 1 D _ Dimension ( B _ NP , A 1jl Weight ll 0.75 1.5 1 3.28 2 2 25 1L 3.114Ibs !f CAST IRON STRAIGHT TEES 1 BLK CI TEE - Ward ID: 2420600003 Mnemonic Code: 1.BCT MIII IN H 0111111 o A---1 �_ 11 Center to !Thread Length !I Outside Dia. Of !, , 1 End i (min) Take Out +! Band (min) it Unit A ! I D l Dimension I, B ,■PS 1 Weight 1 . 5 1_95 - __ _?+ :1 _j:, _ 1 -1/2 BLK CI TEE Ward ID: 2420800003 Mnemonic Code: 1D.BCT _ — _ Milli 01111H D A 0 A :Thread Length i O Dia. Of !I 31� C to 1 1 (min) Take Out Band (min) 1 11 End Unit l D Dimension ! B I NPS �i� A I Weight ii 0.7 1.253 ! 2.68 I !1 1 / 2 2 BLK CI TEE Ward ID: 2420900003 Mnemonic Code: 2.BCT mil• iiiii 1 A F !NW 0 A I !i I! I Thread Length Outside Dia Of . r,1 Center to i! (min) III Take Out i Band (min) Ili 11' End Unit II D 1 Dimension I I B {NPS'i A Weight II 0.75 , i 1.5 ■ 3 28 l 7 2 2 ( � 25 l , - - 4 . 6 9 1 6 s II CAST IRON SOLID PLUGS 1 BLK CI SOLID PLUG - Ward ID: 320600003 Mnemonic Code: 1.BSP K. l c NI ll 9 I i 11111 • Nominal Width of Access Len of Threadi Height of Squarej`; -Unit -1 NPS Flats (min) (min) Weight 1 1 1 _._________ ( 0.75 ' 0.5 ,L0 -331bs J CAST IRON SOLID PLUGS 1 -1/2 BLK CI SOLID PLUG Ward ID: 320800003 Mnemonic Code: 1D.BSP -______O 110 c 11111 8 _ A = i! . 1 jNominal Wi dth of Access Flats � Length of Thread (m in ) 1 �Hei ght of Square (min) 1; 1{NPS 11 C A 1/ B Unit Weight 1/2.�.�- 1 125 I 0 83 � i1 : 0.62 i 0.811-7n1 CAST IRON SOLID PLUGS 2 BLK CI SOLID PLUG Ward ID: 320900003 Mnemonic Code: 2.BSP 0 ,.............. 0 c all ,.# 1.6 B MI MO A A -..._r °. t .._ li I Nominal Width of Access Flatsi,Length of Thread (minyHeight of Square (mm) I C NPSI C �l A B Unit Weight, ? _ � _._...._. __..__. 1 ^ 3125 `.w._.:`_.__.: 068 .__w 1 251bs..: -' ' , . ,:. .,,� , -,c. ax' . tiff ., .d"+a < A r fi 17 "J +4i P d x J . K - q;; . - , r � ® �; �� �,_ t ti�tl� r?t �� � � �� �� ��� .,�' �S �" S s �^^ �F`.s -s � � �� fi,' � aF � , ms`s � ,. � �� I. �� "r �. ,:�'� i ,jai � � , � c 'Y , < «��, ��? a �' � "�„ °, � . fir w �` ` .u#� ��' ` " � a �L'�- t ", r � t� a�� 1 � � . h �cm� , ,,�'A" v �� ~ yy f , vwvw tolco corn .a , .Lr A'3 ti. 1 f `G 4 �' x^h 'Y� n s5`F'4 �� .iA:11�1i'1 C .�..s't7s ..f - .e6 �'r , s z a.*ro .e +-fr' ,8 r✓ fi. �r 3 x<" l* � .11 s2 ® 4s' i'+ar d" a. , ' .' "'V a:',r . x r .ru{"; �> .fr- -:..� • H. +lia -s v 7 ".. -� ' `. " �'"„u 4 .x •): ?, i 5 � ,t ,, xe fib 4 1e 7 , „. ; ,,.'. >n , ,. ,,, ,r ^� .. � ,.' a -F.';4&'-'. • �� ak -, , i , Revision 5124 /2 , . ' 'Yu s #; '7m'C' k,.• .r ;54 rig,. .1 •• o i i (7( �'�� ® .. F i. ' w . :, r, • ,' '''5, '• • '`" . 4 " . M' ° . t :..' 5 v 4 y + -M', *_• �.„ �'r , .... „,,. a s .. . „v<..n, » , .U. w. .., ,�N • ! , Pr -1 " ) ,•'5 . -. ...� -t� Y� t.. 13 �, .. 4 _ . �« .t, r , Lk., qn ." Fig. 98 - Rod Stiffener Size Range — Secures 3/8" thru 7/8" hanger rod Material — Carbon Steel Function — Secures channel to hanger rod for vertical seismic bracing. f. 0- Finish — Electro Galvanized 4. , Note — Available in HDG finish or Stainless Steel materials. '` ; . Ore Order By — Figure number i Fig. 99 - All Thread Rod Cut to Length Size Range — Secures 3/8" thru 7/8" rod in Dimensions • Weights 1" increments ``tl / Rod Max. Rec. Load Lbs. Material — Carbon Steel �� Size For Service Temps �/�� 650 °F 750 °F Maximum Temperature — 750 °F Finish — Plain 312 6 540 �� �- 1 /8 130 1010 Note — Available in Electro- Galvanized and `l(( �� 5/8 1810 10 1610 HDG finish or Stainless Steel materials. lC 3/4 2710 2420 Order By — Figure number, rod diameter, rod 7/8 3770 3360 - length and finish , Fig. 100 - All Thread Rod Full Lengths Size Range — Secures 3/8" thru 7/8" rod in 10' lengths Material — Carbon Steel Maximum Temperature — 750 °F Finish — Plain /fl Note — Available in Electro- Galvanized and '' (:te HDG finish or Stainless Steel materials. Order By — Figure number, rod diameter (� and finish Dimensions • Weights Max Rec. Load Lbs. Rod For Service Temps Approx. et Size 650 °F 750 °F Wt. /100 1/4 240 215 12 3/8 610 540 29 1/2 1130 1010 53 5/8 1810 1610 84 3/4 2710 2420 123 . 7/8 3770 3360 169 1 4960 4420 222 1'/< 8000 7140 360 1 11630 10370 510 u t Main Office /Manufacturing Facility • 1375 Sampson Ave. • Corona. CA 928/9 • Ph: 909./31.5599 • Fax 909.13/0330 6B9 Customer Service • 800 /86 5266 tit www.lolco.com • r-®. r�yr... nW-: �» �. ��r ...:�..�rrr,x. � _ �: -; r �r ?4"� ��... � } �� - s•�'v.';'L ,�;+-�e " �- 5 1: �"ti re' ° �l� n f � "1/ • ��LL d y�� a t �1, "' a* .1x2' , :Y,' x i • • r" 45, ,. . 7 • , ",1 I! • ,��v� as x T F. .. i #'..'x' � ` "T .K 1" � 71: It" " � , w 7 . - e�� � � t r4: .. .4 .�� a iBC� `� � � "_. � �: � �.7 �', VF ��� � evlsl on 1 024 /0 w . , A � e-,V :,.4“. . , ', .,, r ,, .:_. _ < ,. � ? ia° vr, .. � : � r. � `i,!., , gin v7. t*:tOO:IN. . ifkT t � r_ ?; t`iNn$ ; f ; ?�r ,,, ,:44. , �x :14 - Fig. 200 - "Trimline" Adjustable Band Hanger (ja Size Range — 1/2" thru 8" pipe ®c® T. Material — Carbon Steel, Mil. Galvanized to G90 kin specifications f f Function — For fire sprinkler and other general piping V i Knurled swivel nut design permits hanger �`i ''•r "Y= 1 ` purposes. 9 P 9 � r .: r i, �-- Ir; 'i 1 r adjustment after installation. --i i )I l �, ,; -,�, i 1� y y ■ Features — i. i I t ,ti i 1t , 1 � ' ' t • (1/2" thru 2 ") Flared edges ease installation for :7 I � ; 4 . ' ; ! Ii , }•__ t II I i I, ? '-1 ,' Ii all pipe types and protect CPVC plastic pipe from z I( s'. B �f iii l 1 adjusting P design keeps J 9 nut 1 � � �, a Captured desi n kee s , l 1i � i i � i ? from separating with hanger. Hanger is easily A ' i; ; � h r+ f t '1 %, �,. '/ `` I installed around pipe. i ,, I, ���_� :;„ �. ( • (2'/2" thru 8" Spring tension on nut holds it ( -' securely in hanger before installation. Adjusting j ' nut is easily removed. j Approvals — Underwriters' Laboratories listed 1/2 pp ' (1/2" ( t. thru 8 ") in the USA (UL) and Canada (cUL) for steel 1f2 THRU 2 INCH PIPE 2 172 THRU 8 INCH PIPE and CPVC plastic pipe and Factory Mutual Engineering Approved (3/4" thru 8 "). Conforms to Federal Specifications WW -H -171 E, Type 10 and Manufacturers . - Standardization Society SP -69, Type 10. '" Maximum Temperature — 650 °F ,...____ _. _ Finish — Mil. Galvanized. For Stainless Steel materi- ; t ;.k '', ,, als, order TOLCOTM Fig. 200WON. ii °`' �'�` . ��� t' if Order By — Figure number and pipe size � � ,, r ! I z ,i i . l IP f it 11 ',"/'N' i j Dimensions • Weights Pipe Rod Size Max. Rec. Approx. Size Inch Metric A B Load Lbs. Length 1/2 3/8 8mm or 10mm 318 2 /8 400 11 3/4 3/8 8mm or lOmm 318 2 400 11 1 3/8 8mm or 10mm 3 218 400 12 1' /4 3/8 8mm or 10mm 3 2'/8 400 13 - 1'/2 3/8 8mm or 10mm 3'/ 2'/8 400 14 2 3/8 8mm or lOmm 4 3 400 15 - 2' /2 3/8 lOmm 5 4 600 27 3 3/8 lOmm 5 4 600 29 3' /2 3/8 lOmm 7 5 600 34 _ 4 3/8 lOmm 7' /8 5 1000 35 5 1/2 12mm 918 6 1250 66 6 1/2 12mm 10 614 1250 73 8 1/2 12mm 13 814 1250 136 Main Office /Manufacturing Facility • 1375 Sampson Ave. • Corona, CA 928/9 • Ph: 909 73/ 5599 • fax 909 73/0330 86., Customer Service • 800.786.5266 — „ www.tofco.com • Back to Application Guide TEXTRON Fastening Systems S P E C I F I C A T I O N S HangerMate® Threaded Rod EZH665 HangerMate Anchors Anchoring System Application Material: EZH665 Anchors Wood Specification: 5/16" threaded shank diameter, one - piece anchor with o rs, twin -lead threads Type 17 p high-low, waxed threads, e point and cross - drilled �) head to accept 3/8 " -16 threaded rod components cross - drilled , >> FM Approvals and UL Listings: to accept �� • cULus Listed for pipe up to 3-1/2" diameter 3/8 -16 threaded rod Head Style: components 3/4" high, 9/16" diameter head cross - drilled and tapped to accept 3/8 " -16 threaded components Features & Benefits Drive Hex Size: • Cross - drilled and tapped for attaching 3/8 -16 1 /2" across flats threaded components to wood • Solid, one piece cold formed part; head cannot spin Shank Length: off or unscrew from body 2-1 /4 tt • Type 17 point cuts threads into wood and wax Shank Threads: coating reduces installation torque 5/16"-14 14 high -low threads (waxed) Point Type: Performance Values for EZH665 Anchor Type 17 (waxed) with shank slot Average Ultimate Pull-Out Value (Ibs) Material & Heat Treat Douglas Fir Southern Pine Hem Fir Carbon steel (AISI C 10B21); no heat treat 1801 1460 1451 Finish: Zinc plated per ASTM B633 Type II Class 12 Installation Tools: • HangerMate drive socket: EZE215 with safety set feature; automatically disengages when anchor is seated • Recommended power tool: Contractor -grade screw gun; 12 volt min. cordless or 6 amp. corded tool • In most applications, a pre - drilled hole is not needed. In exceptionally hard wood, drill hole only to minimum size required. 1. The loads indicated above are average ultimate values achieved under laboratory conditions and appropriate safety factors should be applied for design purposes. 2. NFPA (National Fire Protection Assoc.) minimum fastening requirements ore five times the weight of a 15 ft section of water - filled pipe plus 250 Ibs. This is 1475 Ibs. for 4" pipe. 3. All test values were obtoined using 3/8-16 rod. When 1/4-20 rod is used, the strength of the rod may be less than the pull-out volues of the anchors. For more information, contact 4. Loads were determined by resting products in the orientation for which they were Textron Fastening Systems • 1.800.435.7213 designed to be used. End - drilled parts were pulled in line with the anchor's axis while cross - drilled parts were tested with the force perpendicular to the axis. e-mail: info@th.textron.com HnnnPrMnfa® ie n rsnicferprl trnrlPmnrlr nF TPSrtresn Inr Fire & Building - tqC 1 li Products [CENT E' AL Customer Service /Sales: Technical Services: Tel: (800) 381 -9312 / Fax: (800) 791 -5500 Tel: (215) 362 -0700 / (800) 523 -6512 Fax: (215) 362 -5385 Series TY-B — 2.6, 5.6, and 6.0 K- factor Upright, Pendent, and Recessed Pendent Sprinklers Standard Resp Standard Coverage General not representative of all possible cor- rosive atmospheres. Consequently, it is recommended that the end user be - Description consulted with respect to the suitability - '"` f ;" of these coatings for any given corro- p, ' - ^- -,' .- —. The Series TY-B, 2.8, 5.6, and 8.0 sive environment. The effects of ambi- , 1 K- f Upright and Pendent Sprin- ent temperature, concentration of r , ' ` 1 • klers described in this data sheet are chemicals, and gas /chemical velocity, ,t - ,- standard response - standard cover- should be considered, as a minimum, age, decorative 5 mm glass bulb type along with the corrosive nature of the ;'., iX— ;,r spray sprinklers designed for use in chemical to which the sprinklers will be °' s -4. M. light, ordinary, or extra hazard, com- exposed. , _' mercial occupancies such as banks, " . . hotels, shopping malls, factories, refin- An intermediate level version of the eries, chemical plants, etc. Series TY B Pendent Sprinkler can be obtained by utilizing the Series TY B - The recessed version of the Series Pendent Sprinkler in combination with TY B Pendent Sprinkler, where appli- the Model S2 Shield. cable, is intended for use in areas with .-.-':.; , a finished ceiling. It uses a two -piece WARNINGS r ; - Style 10 (1/2 inch NPT) or Style 40 (3/4 The Series TV-B Sprinklers described / " ' . inch NPT) Recessed Escutcheon. The herein must be installed and main- / , f Recessed Escutcheon provides 1/2 tained in compliance with this docu- 4 � , I inch (12,7 mm) of recessed adjust- ment, as well as with the applicable k } ment or up to 3/4 inch (19,1 mm) of standards of the National Fire Protec- total adjustment from the flush pen- tion Association, in addition to the dent position. The adjustment provided standards of any other authorities hav- .w. by the Recessed Escutcheon reduces ing jurisdiction. Failure to do so may '' ` _.� the accuracy to which the fixed pipe impair the performance of these de- ^°; drops to the sprinklers must be cut. vices. , Corrosion resistant coatings, where The owner is responsible formaintain- applicable, are utilized to extend the ing their fire protection system and de- life of copper alloy sprinklers beyond vices in proper operating condition. that which would otherwise be ob- The installing contractor or sprinkler tained when exposed to corrosive at- manufacturer should be contacted mospheres. Although corrosion resis- with any questions. tant coated sprinklers have passed the standard corrosion tests of the appli- cable approval agencies, the testing is Model/Sprinkler IMPORTANT Identification Always refer to Technical Data co " Sheet TFP700 for the "INSTALLER N g - WARNING" that provides cautions Numbers a with respect to handling and instal- TY1151 - Upright 2.8K, 1/2 "NPT v lation of sprinkler systems and com TY1251 - Pendent 2.8K, 1/2 " NPT ponents. Improper handling and in- TY3151 - Upright 5.6K, 1/2 "NPT N stallation can permanently damage TY3251 - Pendent 5.6K, 1/2 "NPT r a sprinkler system or its compo- TY4151 - Upright 8.0K, 3/4 "NPT °C nents and cause the sprinkler to fail TY4251 - Pendent 8.0K, 3/4 "NPT `o to operate in a fire situation or cause TY4851 - Upright 8.0K, 1 /2 "NPT a. it to operate prematurely. TY4951 - Pendent 8.0K, 1/2 "NPT Page 1 of 8 JULY, 2004 TFP151 Page 2 of 8 TFP151 ESCUTCHEON 7/16" (11,1 mm) PLATE SEATING * NOMINAL SSU SURFACE NPT MAKE -IN DEFLECTOR 1 S � � 5 2 -3/16° (57,2 4 6 / mm) = R -' (55 ,6 mm) I I i. 2 1 -9/16 ' WRENCH •� f�\ c II (39,7 mm) FLATS SSP 7 DEFLECTOR CROSS PENDENT UPRIGHT SECTION 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression 7 - Bushing orifice seat on frame. Screw * *Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 1 STANDARD RESPONSE SERIES TY -B UPRIGHT (TY1151) AND PENDENT (TY1251) SPRINKLERS 2.8 K- FACTOR, 1/2 INCH NPT ESCUTCHEON 7/16" (11,1 mm) STYLE 10 PLATE SEATING ** NOMINAL RECESSED SURFACE 1/2" PT MAKE-IN ESCUTCHEON DEFLECTOR 6* i -- 7/16" f 5 2- 3/16" 1 � (11,1 mm) (55,6 mm) ��� 111 NOMIN AL 4 t MAKE -IN - 1 �� , i �e.:�_�� 1-1/2" 2 (38,1 mm) (5, mm) 0 II ��� ,�- - WRENCH _ >�' rfr ,� �� �,� FLATS # 0 1 SSP DEFLECTOR . 2 -7/8" (73,0 mm) DIA. — "I 1/2" NPT PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION 1 - Frame 3 - Sealing 4 - Bulb 6 - Detlector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression orifice seat on frame. Screw * *Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 2 STANDARD RESPONSE SERIES TY -B UPRIGHT (TY3151) AND PENDENT (TY3251) SPRINKLERS 5.6 K- FACTOR, 1/2 INCH NPT TFP151 Page 3 of 8 ESCUTCHEON 1/2" (12,7 mm) STYLE 40 . PLATE SEATING ** NOMINAL RECESSED * SURFACE \- iI MAKE -IN ESCUTCHEON DEFLECTOR • r rr i?77-R% 'T"S *;ITT'. 6* 1/2" fr 5 2- 5 / 16 " (12,7 mm) III (58,7 mm) 1111 111 I 7 jf NOMINAL I i 4 f —_ MAKE -IN 1 1-9/16" i��� I� � � i� 2 va° q , 2 39,7 mm ( ) ;11 I �� (57,2 mm) r 0 1 -- -., --- - -• WRENCH 3 - _ I FLATS l III 1 SSP DEFLECTOR 2 -7/8" (73,0 mm) DIA. — •• - i 3/4" NPT ** PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression 7 - Ejection orifice seat on frame. Screw Spring * * Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 3 STANDARD RESPONSE SERIES TY -B UPRIGHT (TY4151) AND PENDENT (TY4251) SPRINKLERS 8.0 K- FACTOR, 3/4 INCH NPT • ESCUTCHEON 7/16° (11,1 mm) PLATE SEATING 1/2° ** NOMINAL SSU SURFACE NPT MAKE -IN DEFLECTOR • = —� ri'i - - il - y► ;:'7TH * "TT• 6 i $ , 5 2-1/4" � --- 2 -3 (57,2 mm) �A = AN (55 ,6 mm) I I 4 1 -9/16° i �Ir WRENCH ������ , '� 2 (39,7 mm) FLATS 7 Y y 1 f 1 SSP DEFLECTOR CROSS PENDENT UPRIGHT SECTION 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression orifice seat on frame. Screw ** Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 4 STANDARD RESPONSE SERIES TY -B UPRIGHT (TY4851) AND PENDENT (TY4951) SPRINKLERS . 8.0 K- FACTOR, 1/2 INCH NPT • • Page 4 of 8 TFP151 SPRINKLER FINISH (See Note 8) K TYPE TEMP. BULB NATURAL CHROME WHITE*** LEAD WAX WAX OVER LIQUID BRASS PLATED POLYESTER COATED COATED LEAD COATED 135 °F /57 °C Orange PENDENT 155 °F /68 °C Red 2.8 (TY1251) 1, 2, 3 N/A 1/2° and 175 °F /79 °C Yellow NPT UPRIGHT 200 °F /93 °C Green (TY1151) 286°F/141°C Blue 360 °F /182 °C Mauve 1,2 135 °F /57 °C Orange PENDENT 155 °F /68 °C Red 1, 2, 3, 4, 5, 6, 7 1,2,3,5 1,2,3,5 1,2,3,5 and 175 °F /79 °C Yellow UPRIGHT 200 °F /93 °C Green 5.6 (TY3151) — 286 °F /141 °C Blue 1 "2" 3" 5** 11" 2" 3" 5" 1/2° — NPT 360 °F /182 °C Mauve N/A 135 °F /57 °C Orange RECESSED 155 °F /68 °C Red PENDENT 1, 2, 3, 4, 5 1, 2, 4, 5 N/A (TY3251)* 175 °F /79 °C Yellow Figure 4 200 °F /93 °C Green 135 °F /57 °C Orange • PENDENT 155 °F /68 °C Red (TY4251) 1,2,5 1,2,3,5 1,2,5 and 175 °F /79 °C Yellow 1, 2, 3, 4, 5, 6, 7 8.0 UPRIGHT 200 °F /93 °C Green 3/4° (TY4151) 286 °F /141 °C Blue 1" 2" 3" 5" I 1" 2" 5** NPT 360 °F /182 °C Mauve N/A 135 °F /57 °C Orange RECESSED 155 °F /68 °C Red PENDENT 1, 2, 3, 4, 5 N/A (TY4251)' 175 °F /79 °C Yellow Figure 5 200 °F /93 °C Green 135 °F /57 °C Orange PENDENT 155 °F /68 °C Red 8.0 (TY4951) 1/2° and 175 °F /79°C Yellow 1, 2, 3, 5 N/A NPT UPRIGHT 200FI93°C Green (TY4851) 286°F/141°C Blue 360 °F /182 °C Mauve NOTES: 1. Listed by Underwriters Laboratories, Inc. (UL). 2. Listed by Underwriters Laboratories, Inc. for use in Canada (C -UL). • 3. Approved by Factory Mutual Research Corporation (FM). 4. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 007k/03). 5. Approved by the City of New York under MEA 354 -01 -E. • 6. VdS Approved (For details contact Tyco Fire & Building Products, Enschede, Netherlands, Tel. 31 -53- 428 -4444 /Fax 31 -53- 428 - 3377). 7. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/05). 8. Where Polyester Coated, Lead Coated, Wax Coated, and Wax over Lead Coated Sprinklers are noted to be UL and C -UL Listed, the sprinklers are UL and C -UL Listed as Corrosion Resistant Sprinklers. Where Lead Coated, Wax Coated, and Wax over Lead Coated • Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as Corrosion Resistant Sprinklers. • Installed with Style 10 (1/2° NPT) or Style 40 (3/4° NPT) 3/4° Total Adjustment Recessed Escutcheon, as applicable. • 150 °F /66 °C Maximum Ceiling Temperature. "' Frame and deflector only. Listings and approvals apply to color (Special Order). N /A: Not Available TABLE A LABORATORY LISTINGS AND APPROVALS TFP151 Page 5 of 8 2 -7/8" DIA. Ll 5/8±1/4" (73,0 mm) 3/4" (19,1 mm) (15,9±6,4 mm) 2 -1/4" DIA. 1/4" (6,4 mm) WRENCH RECESS (END FACE OF (57,2 mm) MOUNTING E 2 " NPT MODELS) SPRINKLER PLATE "' FITTING 1/8" WRENCH RECESS ��' (3,2 mm) (END "B" USED FOR 1�I 3/4" NPT MODELS) A FIGURE 7 � i W -TYPE 6 SPRINKLER WRENCH MOUNTING , SURFACE'-% - WRENCH CLOSURE SERIES 1 -1/4" (31,8 mm) RECESS TY B 3/4" (19,1 mm) ol FIGURE 5 SERIES TY -B RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO -PIECE 3/4 INCH TOTAL ADJUSTMENT 4: STYLE 10 RECESSED ESCUTCHEON 5.6 K- FACTOR, 1/2 INCH NPT • PUSH WRENCH • INTO ENSURE 2 -7/8" DIA. ENGAGEMENT WITH ,0 mm) 3/4" (19,1 mm) 5/8±1/4" WRENCH N AREA " (15,9±6,4 mm) 2 -1/4" DIA. _ 1/4" (6,4 mm) FIGURE 8 FACE OF (57,2 mm) MOUNTING W -TYPE 7 RECESSED SPRINKLER PLATE SPRINKLER WRENCH FITTING 1/8" ..i (3,2 mm) = M• - -a MOUNTING I . SURFACE CLOSURE SERIES 1- 5/16" (33,3 mm) TY - B 13/16" (20,6 mm) FIGURE 6 SERIES TY -B RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO -PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON 8.0 K- FACTOR, 3/4 INCH NPT Page 6 of 8 TIFP151 ing the wax coating. Before wrench Tech; "®Cal Installation tightening the sprinkler, the jaws of the wrench are to be adjusted to just con- 4 Data Series TY -B Sprinklers must be tact the sprinkler wrench flats. After .. installed in accordance with the follow- wrench tightening the sprinkler, loosen Approvals ing instructions: the wrench jaws before removing the UL and C -UL Listed. wrench. FM, LPCB, VdS, and NYC Approved. NOTES (Refer to Table A for complete approval Do not install any bulb type sprinkler if After installation, the sprinkler wrench information including corrosion resis- the bulb is cracked or there is a loss of flats and frame arms must be in- tant status.) liquid from the bulb. With the sprinkler spected and the wax coating re- held horizontally, a small air bubble touched (repaired) whenever the coat - Maximum Working Pressure should be present. The diameter of the ing has been damaged and bare metal 175 psi (12,1 bar) air bubble is approximately 1/16 inch is exposed. The wax coating on the Discharge Coefficient (1,6 mm) for the 135 °F /57 °C to 3/32 wrench flats can be retouched by gen- K = 2.8 GPM /psi (40,3 LPM/bar / inch (2,4 mm) for the 360 °F /182 °C tly applying a heated 1/8 inch diameter K = 5.6 GPM /psi (80,6 LPM/bar / temperature ratings. steel rod to the areas of wax that have K = 8.0 GPM /psi (115,2 LPM /bar1i2) been damaged, to smooth it back over A leak tight 1/2 inch NPT sprinkler joint areas where bare metal is exposed. Temperature Ratings should be obtained with a torque of 7 Refer to Table A to 14 ft.lbs. (9,5 to 19,0 Nm). A maxi- NOTES Finishes mum of 21 ft. lbs. (28,5 Nm) of torque Only retouching of the wax coating ap- Sprinkler: Reessed Escutcheon: White may be used to install sprinklers with plied to the wrench flats and frame Coated, Chrome Plated, or Brass 1/2 NPT connections. A leak tight 3/4 arms is permitted, and the retouching Plated inch NPT sprinkler joint should be ob- is to be performed only at the time of tained with a torque of 10 to 20 ft.lbs. the initial sprinkler installation. Physical Characteristics (13,4 (40,7 26,8 )m). A maximum of 30 The steel rod should be heated onl y to Frame Bronze ft.lbs. Nm of torque is to be used Button Brass /Copper to install sprinklers with 3/4 NPT con- the point at which it can begin to melt Sealing Assembly nections. Higher levels of torque may the wax, and appropriate precautions • Beryllium Nickel w/Teflont distort the sprinkler inlet and cause need to be taken, when handling the • Bulb Glass leakage or impairment of the sprinkler. heated rod, in order to prevent the • Compression Screw Bronze installer from being burned. • Deflector Copper Do not attempt to make -u for insuffi- If attempts to retouch the wax coating • Bushing (K =2.8) Bronze cient adjustment in the escutcheon with complete lete covers a are oats plate by under- or over - tightening the p g sprinkler. Readjust the position of the cessful, additional wax can be ordered sprinkler fitting to suit. in the form of a wax stick (the end of which is color coded). Only the correct Aeration The Series TY -B Pendent and Up- color coded wax is to be used, and right Sprinklers must be installed in retouching of wrench flats and frame The glass Bulb contains a fluid which accordance with the following instruc- arms is only permitted at the time of expands when exposed to heat. When tions. initial sprinkler installation. With the the rated temperature is reached, the steel rod heated as previously de- fluid expands sufficiently to shatter the Step 1. Pendent sprinklers are to be glass Bulb, allowing the sprinkler to installed in the pendent position, and scri bed, touch the rod to the area re- activate and water to flow. upright sprinklers are to be installed in qui add wax with the rod an- the upright position. gled downward, and then touch the wax stick to the rod approximately Design Step 2. With pipe thread sealant ap- one -half inch away from the area re- plied to the pipe threads, hand tighten quiring retouching. The wax will melt C riteria the sprinkler into the sprinkler fitting. and run down onto the sprinkler. Step 3. Tighten the sprinkler into the The Series TY B Pendent and Upright sprinkler fitting using only the W -Type The Series TY -B Recessed Pendent Sprinklers are intended for fire protec- 6 Sprinkler Wrench (Ref. Figure 7), Sprinklers must be installed in ac- tion systems designed in accordance except that an 8 or 10 inch adjustable cordance with the following instruc- with the standard installation rules rec- Crescent wrench is to be used for wax tions. ognized by the applicable Listing or coated sprinklers. With reference to Step A. A fter installing the Style 10 or Approval agency (e.g., UL Listing is Figures 1, 2, 3, and 4 the W -Type 7 p g ry • based on the requirements of NFPA Sprinkler Wrench or the adjustable 40 Mounting Plate, as applicable, over 13, and FM Approval is based on the Crescent wrench, as applicable is to the sprinkler threads and with pipe requirements of FM's Loss Prevention be applied to the wrench flats. thread sealant applied to the pipe Data Sheets). Only the Style 10 or 40 threads, hand tighten the sprinkler into ` Recessed Escutcheon, as applicable, When installing wax coated sprinklers the sprinkler fitting. is to be used for recessed pendent with the adjustable Crescent wrench, Step B. Tighten the sprinkler into the • installations. additional care needs to be exercised p g p to prevent damage to the wax coating sprinkler fitting using only the W -Type on the sprinkler wrench flats or frame 7 Recessed Sprinkler Wrench (Ref. arms and, consequently, exposure of Figure 8). With reference to Figure 3 or bare metal to the corrosive environ- 4 the W -Type 7 Recessed Sprinkler ment. The jaws of the wrench should Wrench is to be applied to the sprinkler be opened sufficiently wide to pass wrench flats. over the wrench flats without damag Step C. After the ceiling has been in- • FFP151 Page 7 of 8 • stalled or the finish coat has been ap- The owner is responsible for the in- - - plied, slide on the Style 10 or 40 Clo- spection, testing, and maintenance of L Ite sure over the Series TY B Sprinkler their fire protection system and de- pp and push the Closure over the Mount- vices in compliance with this docu- I4larrant ing Plate until its flange comes in con- ment, as well as with the applicable tact with the ceiling. standards of the National Fire Protec- Products manufactured by Tyco Fire tion Association (e.g., NFPA 25), in Products are warranted solely to the Care an addition to the standards of any other original Buyer for ten (10) years id authorities having jurisdiction. The in- against defects in material and work- M � ® stalling contractor or sprinkler manu- manship when paid for and properly aintenance facturer should be contacted relative to installed and maintained under normal The Series TY-B Sprinklers must be any questions. u se a 1 service. This warranty will ex- maintained and serviced in accord- It is recommended that automatic p ( )Years from date of ship - ment ance with the following instructions: sprinkler systems be inspected, ranty is by Tyco given Fire Products. for products by p ro ducts r tested, and maintained by a qualified components o- NOTES Inspection Service in accordance with nies e fi noafrod af filiated bytu by oww nerrship with wit Before closing system local requirements 9 a fire protection Y stem oca requ and /or national Tyco Tyco F Fir ire Products or for products and main control valve for maintenance codes. components which have been subject work on the fire protection system that to misuse, improper installation, corro- it controls, permission to shut down the sion, or which have not been installed, affected fire protection system must be maintained, modified or repaired in ac- obtained from the proper authorities cordance with applicable Standards of and all personnel who maybe affected the National Fire Protection Associa- by this action must be notified. tion, and /or the standards of any other Absence of an escutcheon, which is Authorities Having Jurisdiction. Mate - used to cover a clearance hole, may rials found by Tyco Fire Products to be delay the time to sprinkler operation in defective shall be either repaired or a fire situation. replaced, at Tyco Fire Products' sole • option. Tyco Fire Products neither as- Sprinklers that are found to be leaking sumes, nor authorizes any person to or exhibiting visible signs of corrosion assume for it, any other obligation in must be replaced. connection with the sale of products or Automatic sprinklers must never be parts of products. Tyco Fire Products painted, plated, coated or otherwise shall not be responsible for sprinkler altered after leaving the factory. Modi system design errors or inaccurate or tied sprinklers must be replaced. incomplete information supplied by Sprinklers that have been exposed to Buyer or Buyer's representatives. corrosive products of combustion, but IN NO EVENT SHALL TYCO FIRE have not operated, should be replaced PRODUCTS BE LIABLE, IN CON - if they cannot be completely cleaned TRACT, TORT, STRICT LIABILITY OR by wiping the sprinkler with a cloth or UNDER ANY OTHER LEGAL THE - by brushing it with a soft bristle brush. ORY, FOR INCIDENTAL, INDIRECT, Care must be exercised to avoid dam- SPECIAL OR CONSEQUENTIAL age to the sprinklers - before, during, DAMAGES, INCLUDING BUT NOT and after installation. Sprinklers darn- LIMITED TO LABOR CHARGES, RE- aged by dropping, striking, wrench GARDLESS OF WHETHER TYCO twist/slippage, or the like, must be re- FIRE PRODUCTS WAS INFORMED placed. Also, replace any sprinkler that ABOUT THE POSSIBILITY OF SUCH has a cracked bulb or that has lost DAMAGES, AND IN NO EVENT liquid from its bulb. (Ref. Installation SHALL TYCO FIRE PRODUCTS' LI- Section). ABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. Frequent visual inspections are rec- THE FOREGOING WARRANTY IS ommended to be initially performed for MADE IN LIEU OF ANY AND ALI. corrosion resistant coated sprinklers, OTHER WARRANTIES EXPRESS OF after the installation has been com- pleted, to verify the integrity of the cor- IMPLIED, INCLUDING WARRANTIES rosion resistant coating. Thereafter, OF MERCHANTABILITY AND FIT- annual inspections per NFPA 25 NESS FOR A PARTICULAR FUR- . should suffice; however, instead of in- POSE specting from the floor level, a random sampling of close -up visual inspec- tions should be made, so as to better determine the exact sprinkler condi- tion and the long term integrity of the corrosion resistant coating, as it may be affected by the corrosive conditions present. • • Page 8 of 8 11712151 P/N 57 -XXX -X -XXX i I I `. SPRINKLER TEMPERATURE MODEL/SIN RATING 530 2.8K UPRIGHT (1/2 "NPT) TY1151 1 NATURAL BRASS 135 135 °F /57 °C 531 2.8K PENDENT (1/2 "NPT) TY1251 4 WHITE POLYESTER 155 155 °F /68 °C 570 5.6K UPRIGHT (1/2 "NPT) TY3151 3 WHITE (RAL9010)* 175 175 °F /79 °C 571 5.6K PENDENT (1/2 "NPT) TY3251 9 CHROME PLATED 200 200FI93°C 590 8.0K UPRIGHT (3/4 "NPT) TY4151 7 LEAD COATED 286 286 °F /141 °C 591 8.0K PENDENT (3/4 "NPT) TY4251 6 WAX COATED 360 360 °F /182 °C 286 °F /141 °C MAX. 560 8.0K UPRIGHT (1/2 "NPT) TY4851 8 WAX OVER LEAD 561 8.0K PENDENT (1/2 °NPT) TY4951 286 °F /141 °C MAX. * Eastern Hemisphere sales only. TABLE B PART NUMBER SELECTION SERIES TY -B PENDENT AND UPRIGHT SPRINKLERS Recessed Escutcheon: Wax Sticks: Ordering Specify: Style (specify) Recessed Es- (for retouching wrench damaged cutcheon with (specify finish), P/N wax coating) Procedure (specify). Specify: (Specify color) color coded When placing an order, indicate the full 1/2° (15 mm) Wax Stick for retouching (specify tem- product name. Refer to the Price List Style 10 perature rating) temperature rated Se- for complete listing of Part Numbers. Chrome Plated P/N 56- 701 -9 -010 ries TY-B Sprinklers, P/N (specify). P g 1/2" (15 mm) Contact your local distributor for avail- Style 10 Black for 135 °F P/N 56 -065 -1 -135 ability. White Color Red for 155 °F P/N 56- 065 -1 -155 Coated P/N 56-701-4-010 Yellow for 175 °F P/N 56- 065 -1 -175 1/2" (15 mm) Blue for 200 °F and Sprinkler Assemblies with NPT Style 10 286°F P/N 56-065-1-286 Thread Connections: White RAL9010" P/N 56- 701 -3 -010 Specify: (Specify Model /SIN), Stand- 1/2" (15 mm) Response, (specify K-factor), 10 NOTES and Res P (P Y ) Brass Plated P/N 56- 701 -2 -010 Each wax stick is suitable for retouch - (specify temperature rating), Series 3/4" (20 mm) ing up to twenty -five sprinklers. TY -B (specify Pendent or Upright) Style 40 Sprinkler with (specify type of finish or Chrome Plated P/N 56- 700 -9 -010 The wax used for 286 °F sprinklers is coating), P/N (specify from Table B). 3/4" (20 mm the same as for 200°F sprinklers, and, Style 40 White Color therefore the 286°F sprinkler is limited Coated P/N 56 -700 -4 -010 to the same maximum ceiling tempera - 3/4" (20mm) ture as the 200 °F sprinkler (i.e., Style 40 150 °F). White RAL9010" P/N 56- 700 -3 -010 3/4° (20 mm) Style 40 Brass Plated P/N 56- 700 -2 -010 Eastern Hemisphere sales only. Sprinkler Wrench: Specify: W -Type 6 Sprinkler Wrench, P/N 56- 000 -6 -387. Specify: W -Type 7 Sprinkler Wrench, P/N 56- 850 -4 -001. TYCO FIRE PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446