Loading...
Permit CITY TIGARD MECHANICAL PERMIT COMMUNITY DEVELOPMENT PERMIT #: MEC2008 - 00482 TIGA 13125 SW Hall Blvd., Tigard, OR 97223 503.639.4171 DATE ISSUED: 10/23/2008 PARCEL: 2S102CB - 03200 SITE ADDRESS: 09975 SW FREWING ST 1020 ZONING: C - SUBDIVISION: MASSIH OFFICE BLDG LOT: 021 JURISDICTION: TIG PROJECT: VISION WORLD Project Description: Mechanical TI - Project Value: $27,000 CLASS OF WORK: ALT FLOOR FURN: EVAP COOLERS: TYPE OF USE: COM UNIT HEATERS: 1 VENT FANS: 3 OCCUPANCY GRP: B VENTS W/O APPL: VENT SYSTEMS: STORIES: 2 BOILERS /COMPRESSORS HOODS: FUEL TYPES 0 - 3 HP: DOMES. INCIN: NAT 3 - 15 HP: 2 COMML. INCIN: MAX INPUT: BTU 15 - 30 HP: REPAIR UNITS: FIRE DAMPERS ?: 30 - 50 HP: WOODSTOVES: GAS PRESSURE: 50 + HP: FURN < 100K BTU: AIR HANDLING UNITS CLO DRYERS: FURN > =100K BTU: <= 10000 cfm: OTHER UNITS: > 10000 cfm: GAS OUTLETS: 2 Owner: FEES MASSIH LLC Description Date Amount PO BOX 108 BEAVERTON, OR 97075 [MECH] Permit Fee 10/23/20( $461.00 [MECPLN] Plan Rev 10/23/20( $115.25 [TAX] 12% State Surch 10/23/20C $55.32 Phone: Total $631.57 Contractor: JET HEATING INC PO BOX 7362 SALEM, OR 97303 REQUIRED ITEMS AND REPORTS Contact #: PRI 503- 363 -2334 Reg #: LIC 3944 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of Ore. Specialty Codes and all other applicable laws. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more than 180 days. ATTENTION: Oregon law requires you to follow rules adopted in the Oregon Utility Notification Center. Those rules are set forth in OAR 952 - 001 -0010 through OAR 952 - 001 -0100. You may obtain copies of these rules or direct questions to OUNC by calling 503.246.6699 or 1.800.332.2344. i fs Issu: d By: Permittee Signature: ( Call 503.639.4175 by 7:00 a.m. for inspections that busin day. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. iii[ -03 W oP ---�D 9 9 ti rawicoe:;- ': , F i + r : , p• r ,, hay ¢� ' r �q r 'Mechanical Permit A li cat ion GE C �� T �,� 4 � ` ' i z k ' _ ' r + , pp ��, ��a� � ^I Io � ; lz o f i IC usl oN i:l � .� i�,r � ,4: k .:,� " Receiv �; Cit of Ti 9/No Permit rr$ �pQ r 4 -, Date/By: '` J� dl - is ` , 13125 SW Hall Blvd., Tigard, OR 97223 e � � /d �� l '_ Plan Revie � Ali �^� a - , g � Phone: 503.639.4171 Fax: 503.598.1960 Bate /By: �il •� (OR 'y Other Permit: T I G n R D Inspection Line: 503.639.4175 c. 1 3 G i` 0 . Ready :y: /� ® See Page 2 for Internet: www.tigard- or.gov Gil 11 �,�Qs Vl, t I ed/Method: n /, l )� / 1 Supplemental Information TYPE OF WORK''' ORK ' COMMERCIAL FEE* SCHEDULE - USE CHECKLIST Mechanical permit fees* are based on the value of the work ❑ New construction CaAddition /alteration/replacement performed. Indicate the value (rounded to the nearest dollar) of all ❑ Demolition ❑ Other: mechanical materials, equipment, labor, overhead, and profit. CATEGORY OF CONSTRUCTION Value: $ ,], MC) RESIDENTIAL EQUIPMENT / SYSTEMS FEES* ❑ I and 2 family dwelling Commercial/industrial ❑ Accessory building For special information use checklist. ❑ Multi- family ❑ Master builder ❑ Other: Description I Qty. 1 Ea. I Total JOB SITE INFORMATION AND LOCATION Heating/cooling Ai Job site address: C1 C 1fS < "Y,4�vV i 4 ' r re wifires res conditioning site I to plan showing sho win t lacement ) 14.00 City/State /ZIP:' '; 10,1 `l. 3 Furnace 100,000 BTU (ducts/vents) 14.00 / Furnace 100,000+ BTU ( ducts/vents) 17.90 SSuite/bldg./apt. L apt. no.: / Project name' JI ► ... 5r .. ‘ -x\i ti-,1\121, Gas heat pump 14.00 Cross street/directions to job site: Duct work 10.00 Hydronic hot water system 14.00 Residential boiler (radiator or hydronic) 14.00 Unit heaters (fuel -type, not electric), in -wall, in -duct, suspended, etc. 14.00 Flue/vent for any of above 6.80 Subdivision: I Lot no.: Other: 10.00 Tax map /parcel no.: Other fuel appliances DESCRIPTION OF WORK Water heater 10.00 - Gas fireplace 10.00 U k T_ J4 M AV ' Flue vent for water heater or gas fireplace 10.00 Log lighter (gas) 10.00 Wood/pellet stove 10.00 Wood fireplace/insert 10.00 Chimney /liner /flue /vent 10.00 ❑ PROPERTY OWNER I C�TENANT Other: 10.00 Name: , \ (SY-N J? .(�� _ Environmental exhaust and ventilation Address: vv Range hood/other kitchen equipment 10.00 City/State /ZIP: Clothes dryer exhaust 10.00 Single -duct exhaust (bathrooms, Phone: ( ) Fax: ( ) toilet compartments, utility rooms) 6.80 APPLICANT ❑ CONTACT PERSON Attic /crawlspace fans ``C.1�-�' 10.00 ,, -� Other: I 10.00 Business name: .��±- '�1 U� Fuel piping Contact name: $5.40 for first four; $1.00 for each additiona Address: Furnace, etc. Gas heat pump City/State /ZIP: Wall/suspended/unit heater Phone: ( ) Fax: : ( ) Water heater Fireplace E -mail: - Range CONTRACTOR Barbecue Business name: ikt l l2 l U l v r) Clothes dryer (gas) Other. 1 I I Address: 90 t (.b —l�u a n MECHANIC PERMIT FEES* City/State /ZIP:Z- ,1 ..3 Subtotal Phone: (b "3 ' J 2 -) I Fax: (�1 Bv3. a-Lc)- a. - Minimum permit fee ($72.50) Plan review (25% of permit fee) CCB lic.: t 10 LIl} State surcharge (12% of permit fee) TOTAL PERMIT FEE Authorized si atu This permit application expires if a permit is not obtained within 180 days after it has been accepted as complete. 1 Print name: i.) Date: ci.` , l "n'Tn * Fee methodology set by Tri- County Building Industry Service Board • City of Tigard, Oregon o 13125 SW Hall Blvd. • Tigard, OR 97223 «17Z - L" s , October 7, 2008 }. .. ,. 0 RE: MECHANICAL TI Project InformationC /;�RD Building Permit: MEC2008 -00482 Construction Type: 5B Tenant Name: Vision World Occupancy Type: B Address: 9975 SW Frewing St. Occupant Load: NA Area: NA Stories: 2 The plan review was performed under the State of Oregon Mechanical Specialty Code (OMSC) 2007 edition; and the State of Oregon Fire Code (OFC) 2007 edition. The following corrections need to be submitted for review prior to issuing of the permit 1) Provide structural design and calculations for vertical and seismic loads from RTU's on the roof. When responding, provide an itemized letter stating in what way each numbered issue has been addressed in the revision. When submitting revised drawings or additional information, please attach a copy of the enclosed City of Tigard, Letter of Transmittal. The letter of transmittal assists the City of Tigard in tracking and processing the documents. Respectfull �, D an Nelson, Senior Plans Examiner (503) 718 -2436 dann @tigard -or.gov Phone: 503.639.4171 o Fax: 503.684.7297 o www.tigard - or.gov o TTY Relay: 503.684.2772 This form is recognized by most Building Departments in the Tri- County area for transmitting information. • Please complete this form when submitting information for plan review responses and revisions. This form and the information it provides helps the review process and response to your project. % BUILDING DIVISION 14: U a Rl'.ar nn M ®��/�$ I$e� ®$p LETTER T R1 aNSMI Y T Ar. . L E II �TI(,A�RD�,- TO: 4f4/ DATE RECEIVED: DEPT: BUILDING DIVISION RECEVED ,,// �� OCT 0 3 2063 FROM: /a (71 OFTIGARD COMPANY: B DIVISION PHONE: 4 5 — c3 47 e By RE: � S <5 � , �- oL A ce. � Q 6S - vvVLz (Srte�ddress) (Permit /Case Number) 9A-5 0 ‘ )fficil (Project name or subdivision name and lot number) ATTACHED ARE THE FOLLOWING ITEMS: Copies: Description: Copies: Description: Additional set(s) of plans. Revisions: iced Cross section(s) and details. Wall bracing and /or lateral analysis. Floor /roof framing. Basement and retaining walls. Beam calculations. Engineer's calculations. Other (explain): REMARKS: FOR OFFICE 1.11E pNLY Routed to Permit Techn�ie�ia •" Date: ld ? (OP) Initialsc -l—B `lti Fees Due: n Yes jf"l�o Fee Description: Amount Due: Special Instructions: Reprint Permit (per PE): Li Yes o ( 1 Done Applicant Notified: Date: Initials: 1. \Building \Forms \Transmittal Letter- Revisions.doc 4/4/07 CITY OF TIGARD BUILDING DIVISION PERMIT #: MFC200R -00482 13125 SW Hall Blvd., Tigard, OR 97223 DATE ISSUED: 1f }/23!)0f18 Phone: (503) 639 -4171 ! f Inspection Requests (24 Hrs.): (503) 639 -4175 ° L. INSPECTION WORKSHEET FOR DATE: 10/29/7008 TIME: 7:OOAM PAGE: 32 SITE ADDRESS: 09975 SW MEWING ST 1020 CLASS OF WORK: SUBDIVISION: MASSIH OFFICE BLDG LOT #: 021 TYPE OF USE: PROJECT NAME: VISION WORLD DESCRIPTION: Mechanical TI - Project Value: $27,000 OWNER: MASSIH Li C, PHONE #: CONTRACTOR: ,ji - r HEATING INC PHON # : 503 - 36.3 -2334 Inspection Request Scheduled For: Date: 1 0/29/2008 Pour Time: Code # Inspection Description Confirm # Contact # Message 616 Mechanical rough -in 077298 -01 503 -4430 N Corrections /Comments /Instructions: . • r. 'AS PARTIAL APPROVAL ❑ CANCEL n NO ACCESS II FAIL �/, CALL FOR INSPECTION ❑ ADDITIO AL FEES ASSESSED Inspector: Date: v nia Phone #: (503) 718 - z.0 S . ' q775 ski F>uA 5± /020 ./UlEC2008 -004-62 i Form 4a Project Name: Vision World Page: 1 l SYSTEMS - GENERAL Applicability Plans /Specs Discussion of qualifying Show compliance by including a draw�Cgh�tl8umber, exceptions on page 4-25 specification section and subparagrap . 1. Applicablity (Section 1317) CITY OFTIGARD • Is this form required? BUILDING DIVISION 12 Form Required. Complete form if a new HVAC system is being installed, or components of an . existing HVAC system are being replaced (I.e., equipment, controls, ductwork, and insulation.) ❑ Exception. The building or part of the building qualifies for an exception from HVAC code requirements. Applicable code exception is Section 1317.1. Portions of the building that qualify: Area: Exception 0-1 D -2 D -3 Area: Exception 0-1 D -2 D -3 Area: Exception D -1 D -2 D -3 D Form Not Required. This project does not contain work required to comply with code. 2. Simple or Complex Systems (Section 1317.9 or 1317.10) o Simple System. Building contains only Simple HVAC System(s). Complete this form (4a) and equipment efficiency worksheets as required. Form 4b is not required. ❑ Complex System. Project includes a Complex System. Complete this form (4a), form 4b and equipment efficiency worksheets as required. 3. Equipment Performance (Section 1317.5) ❑ No New HVAC Equipment. The building plans do not call for new electrical HVAC equipment, combustion heating equipment, or heat - operated cooling equipment. El Complies. All new HVAC equipment have efficiencies not less than those required by code. The following equipment efficiency worksheets are attached: GI -4a 0 -4b 0 -4c 0 -4c El -4e 0 -4f 0 -4g ❑ 411 D -4i D-4 4. Duct Insulation and Sealing (Sections 1317.7 & 1317.8) D No Ducts. The building plans and specifications do not call for new HVAC ducts or plenums. El Complies. The plans and specifications call for all air - handling ducts and plenums to be insulated and sealed as reauired by Sections 1317.7 &1317.8. 5. Distribution Transformers (Section 1316.1) • ❑ No Distribution Transformers. The plans /specs do not call for new distribution transformers. El Complies. All new distribution transformers comply with efficiency, testing, and labeling requirements of Section 1316.1.1. Exception. The project qualifies for an exception per Section 1316.1.1, Exceptiion: 0- D -2 D -3 0-4 0-5 D -s 0-7 D -8 0- 0-10 D-r 0-12 D -12 D -14 y . Attach relevant documentation for appropriate exception. The plans /specs show compliance in ° „ the following locations: 4 -1 April 2005 Compliance with OSSC, effective 01/01/05 ' Form 4a Project Name: Vision World Page: 2 SYSTEMS - GENERAL 6. HVAC Controls (Section 1317.4) 6.1 System Thermostat /Zone Controls (Section 1317.4.1) O Complies. All new HVAC systems include at least one temperature control device responding to temperatures within the zones. ❑ Exception. HVAC system qualifies for an exception from zone control requirements. The applicable code exception is Section 1317.4.2, Exception 0-1 0-2 Portions of the building that qualify: The plans /specs show compliance in the following locations: 6.2 Off - hour Controls - Auto Setback or Shutdown (Section 1317.4.3) ❑ Complies. Systems must have at least one of the following features: O Control Setback Complies. Each system is equipped with automatic control capable of reducing energy through control setback during periods of non -use or alternate use of spaces served. ❑ Equipment Shutdown Complies. Each system is equipped with controls capable of reducing energy use through automatic shutdown during periods of non -use or alternate use of spaces. HVAC systems with equipment shutdown are equipped with at least one of the following: ❑ Programmable controls (1317.4.3.1 (1)) ❑ Occupant sensor (1317.4.3.1 (2)) ❑ Interlocked to a security system (1317.4.3.1 (3)) ❑ Manually activated timers with 2 -hour operation max (1317.4.3.1 (4)) ❑ Exception. The building qualifies for an exception to the requirement for automatic setback or shutdown controls. The applicable code exception is Section 1317.4.3 Exception 0-1 0-2 The plans /specs show compliance in the following locations: 6.3 Control Capabilities (Sec. 1317.4.2.1) O Complies. Zone thermostats are capable of being set to the temperatures described in Sec. 1317.4.2.1. Where used to control both heating and cooling, zone controls shall be capable of providing a temperature range or deadband of at least 5 degrees F within which the supply of heating and cooling energy to the zone is shut off or reduced to a minimum. ❑ Exception. The building qualifies for an exception to the deadband requirements. The applicable code exception is Section 1317.4.2.1 Exception 0-1 0 -2 Portions of the building that qualify: The plans /specs show compliance in the following locations: 6.4 Optimum Start Controls (Section 1317.4.3.2) O Complies. Separate HVAC systems have controls capable of varying start-up time of system to just meet temperature set point at time of occupancy. ❑, Exception. HVAC systems have a design supply air capacity not exceeding 10,000 cfm. The plans /specs show compliance in the following locations: 6.5 Heat Pump Controls (Section 1317.4.4) 0' NO Heat Pump. The plans /specs do not call for a new heat pump • ❑ Complies. All new heat pumps equipped with supplementary heaters are controlled to minimize • the use of supplemental heat as defined in Section 1317.4.4. The plans /specs show compliance in the following locations: 4 -2 April 2005 Compliance with OSSC. effective 01/01/05 Form 4a Project Name: Vision World Page: 3 • SYSTEMS - GENERAL 7. Economizer Cooling (Section 1317.3) ❑ No Cooling. The building plans do not call for a new fan system with mechanical cooling. El Complies. Each new fan system has an air economizer capable of modulating outside -air and return -air dampers to provide up to 100 percent of the design supply air as outside air. ❑ Exception At least one new fan system qualifies for an exception. The applicable code exception is Section 1317.3, Exception 0 -1 ❑ -2 ❑ -3 111-4 III -5 ❑ -6 If Exception 3 is selected complete the following: (a) Total cooling capacity of exempt units (Btu /hr) (b) Total installed building cooling capacity (Btu /hr) ❑ Complies. Sum of exempt units rated at less than 54,000 Btu /hr is <240,000 Btu /hr or a/b < 0.10 (10% of total building cooling capacity). Unit Identifier of exempt units: The plans /specs show compliance in the following locations: 8. Economizer Pressure Relief & Integration (Section 1317.3.1 and 1317.3.2) ❑ No Economizers Required. Project does not contain a new fan system requiring economizers. ❑ Overpressurization Complies. The drawings specifically identify a pressure relief mechanism for each fan system that will relieve the extra air introduced by the economizer. El Integration Complies. Economizer is capable of providing partial cooling even when additional mechanical cooling is required to meet the remainder of the cooling load. ❑ Exception. The applicable exception is Section 1317.3.2, Exception l=1-1 ❑ -2 - The plans /specs show compliance in the following locations: 9. Hot Gas Bypass (Section 1317.5) El No Hot Gas Bypass ❑ Complies. See allowable amount of hot gas bypass as a percentage of total cooling capacity in table below. Unit ID Rated Cooling Capacity Hot Gas Bypass Capacity s Allowable Hot Gas Bypass • k Rated Cooling Capacity Max Hot Gas Bypass r, <240,000 Btu /hr 50% '` >240,000 Btu /hr 25% 9 Exception. Unitary packaged system with cooling capacity no greater than 90,000 Btu /h 4 -3 April 2005 Compliance with OSSC, effective 01/01/05 • • Form 4a Project Name: vision World Page: 4 SYSTEMS - GENERAL 10. Shutoff Dampers (1317.4.3.3) El Not Required. Shutoff dampers are not required on this project. o Complies. Each outdoor air supply & exhaust system shall be equipped with motorized dampers. ❑ Exception. The building qualifies for an exception to the motorized damper requirement. The applicable code exception is Section 1317.4.3.3 Exception ❑ -1 ❑ -2 ❑ -3 ❑ -4 ❑ -5 1=1-6 The plans /specs show compliance in the following locations: 10.1. Shutoff Damper Controls (Section 1317.4.3.3.1) G Complies. Outdoor air supply and exhaust systems shall be provided dampers that automatically shut when systems or spaces served are not in use or during building warm -up, cooldown, or setback. ❑ Complies. Stair and shaft vents are capable of being automatically closed during normal building operation and interlocked to open as required by fire and smoke detection systems. The plans /specs show compliance in the following locations: . 10.2. Motorized Damper Leakage (1317.4.3.3.2) o Complies. Motorized outdoor air supply and exhaust air dampers have a maximum leakage rate of 4 cfm /ft2 at 1.0 in w.g. when tested in accordance with AMCA Standard 500 -1998. ❑ Exception. Packaged HVAC equipment may have maximum leakage rate of 20 cfm /ft at 1.0 in w.g. when tested in accordance with AMCA Standard 500 -1998. The plans /specs show compliance in the following locations: - 11. Piping Insulation (Section 1314) ❑ No New Piping. The building plans and specifications do not call for new piping serving a heating or cooling system or part of a circulating service water heating system. G Complies. All new piping serving a heating or cooling system or part of a circulating service water heating system complies with the requirements of the Code, Section 1314.1. ❑ Exception. New piping qualifies for exception: Section 1314.1, Exception ❑ -1 0 -2 12. Occupancy Ventilation El Complies. Mechanical ventilation systems provide the required amount of ventilation is indicated in plans /specifications as specified in Chapter 4 of the Oregon Mechanical Specialty. Code. ❑ Complies. Natural ventilation systems provide required amount of ventilation as certified by a reg- istered architect or engineer as specified by Section 1203.4.1, Exception. Attach worksheet 4m. . The plans /specs show compliance in • the following locations: The plans /specs show compliance ''15' e on the following pages: • vet leAo 4 -4 April 2005 Compliance with OSSC, effective 01/01/05 Form 4a Project Name: vision world Page: 5 SYSTEMS - GENERAL 13. High Occupancy Ventilation (Section 1317.2.2) ❑ Complies. HVAC systems with ventilation air capacities of 1,500 CFM or greater that serve areas having an average occupant load of 20 square feet per person or less from Table 1004.1.2 have a means to automatically reduce outside air intake. Identify applicable systems: Plans /specs indicate where equipment (i.e. carbon dioxide sensor) and sequence is specified: ❑ Exception. HVAC systems are equipped with an energy recovery device with at least 50% recovery effectiveness. O No High Occupancy Systems. Project does not contain an HVAC system as described above. 14. Exhaust Air Heat Recovery (Section 1318.3) O Not Regulated. HVAC system does not have: 1) design supply air cap. of >10,000 cfm, and 2) min. outside air supply >70 %, and 3) at least 1 exhaust fan rated at 75% of min outside air supply. ❑ Complies. Heat recovery system increases outside air temperature by 20 °F (Climte Zone 1) or 30 °F (Zone 2) and has provision to provide bypass during air economizer mode. ❑ Exception. An HVAC system qualifies for an exception to this requirement. Applicable exception from Section 1318.3 Exception0- 0 -2 0-3 0-4 0-5 0-6 0-7 The plans /specs show compliance in the following locations: 15. Large Volume Fan Systems (Section 1318.4.2.4) O Not Regulated. The building plans or specifications do not call for fan systems over 15,000 CFM that serve a single zone and function for the purpose of temperature control. ❑ Complies. Fan systems are equipped with variable frequency drive or two speed motor to reduce airflow as required by Section 1318.4.2.3. The plans /specs show compliance in the following tnr otinnc• 16. Variable Speed Drives (Section 1317.10.3.1) O Not Regulated. The building plans or specifications do not call for fan and pump motors 10 - horsepower and greater that serve variable -flow air or liquid systems. ❑ Complies. All fan and pump motors 10 hp and greater which serve variable -flow air or liquid systems are controlled by a variable -speed drive. ❑ Exception. The building qualifies for an exception to the variable -speed drive requirement. Portions of the building that qualify: Applicable code exception is Section 1317.10.3.1, Exception The plans /specs show compliance in the following Inr•otinnc- 17. Service Water Heating (Sec. 1315) O No New Water Heating. The building plans and specifications do not call for new water heaters, hot water storage tanks or service hot water distribution systems. ❑ Complies. All new water heaters, hot water storage tanks or service hot water distribution systems comply with the requirements of the Section 1315. • 0 Exception. The applicable code exception is Section: Exception: 6fT4. p �, Portions of the building that qualify: a°.� The plans /specs show compliance in the following locations: 4 -5 April 2005 Compliance with OSSC, effective 01/01/05 ■ . • Form 4a Project Name: Vision World Page: 6 SYSTEMS - GENERAL • 18. Swimming Pools, Spas and Hot Tubs (Section 1315.5) O No New Pools. The building plans and specifications do not call for new, swimming pools, spas or hot tubs. ❑ On /Off Controls Complies. Spa and hot tub heaters are equipped with a readily accessible ON /OFF switch as required by Section 1315.5.1. El Ventilation Controls Complies. Pool ventilation system is controlled based on humidity. El Cover Complies. All heated pools, hot tubs and spas are equipped with a cover. ❑ Heat Recovery Complies. Pools, Spas, and hot tubs, over 200 ft utilize recovered heat as required by Section 1315.5.3. El Exception. Heat recovery is not necessary as pool is heated by renewable energy or waste heat recovery sources capable of providing at least 70 percent of the heating energy required over an operating season. 19. Fume Hoods (Section 1317.2.1.) O No Fume Hoods. The building plans do not call for fume hood systems that have a total exhaust rate greater than 15,000 cfm. ❑ Complies. Fume hood systems have at least one of the following features: El Variable air volume hood exhaust and room supply systems capable of reducing exhaust and makeup air volume to 50% or less of design values. El Direct makeup (auxiliary) air supply equal to at least 75% of the exhaust rate, heated no warmer than 2° F below room set point, cooled no cooler than 3° F above room set point, no humidification added, and no simultaneous heating and cooling used for dehumidification control. El Heat recovery systems to precondition makeup air from fume hood exhaust in accordance with 1318.3 - Exhaust Air Energy Recovery, without using any exception. The plans /specs show compliance in the following locations: • 20. Parking Garage Ventilation (Section 1317.2.3) O No Enclosed Garages. The building plans and specifications do not call for enclosed Group S -2 parking garages with a ventilation exhaust rate greater than 30,000 CFM. ❑ Complies. The plans and specifications call for carbon monoxide sensing devices as required by Section 1317.2.3. ❑ Exception. Open parking garages. 21. Kitchen Hoods (Section 1317.11) . 0 Not Regulated. The plans /specs do not call for any new kitchen hoods with exhaust capacity greater than 5,000 cfm each. ❑ l Complies: All new kitchen hoods with a total exhaust capacity greater than 5,000 cfm have at least 50 percent of the required makeup air; (a) unheated or heated to no more than 60 °F; and (b) uncooled or evaporatively cooled. 4 The plans /specs show compliance in . the following locations: 0 22. Outside Heating Systems (Section 1317.12) 0 No Outside Heating Systems. The plans /specs do not call for new permanently installed heating • systems outside the building. ❑ Complies. All permanently installed outside heating systems are radiant gas fired systems controlled by an occupancy sensor or timer switch as required by Section 1317.12. 4 -6 April 2005 Compliance with OSSC, effective 01/01/05 Worksheet 4a Project Name: Vision World Page: 7 ' . UNITARY AIR CONDITIONER - AIR COOLED Equipment (a) (b) (c) (d) (e) Proposed Performance Discussion of equipment Cooling Seasonal or Compliance ratings and equipment Equip. ID Model Designation Capacity Steady State Part Load Schedule (A -E) definitions on page 4-19. RTU -1 Carrier 48TMD008 90,000 13.1 SEER C • RTU -2 Carrier 48TME007 72,000 13.1 SEER C • Required Indicate source of information Document- ❑ ARI Unitary Directory, Section AC, page: ation . ❑ ARI Applied Products directory, Section ULE, page: ❑ Product data (Attach data furnished by the equipment supplier, I.e., "cut sheets ") Code Required Cooling Capacity (btu /hr) Minimum Rating Efficiencies Compliance Seasonal or Schedule Equipment Type Over . But not over- Steady. State ,Part Load 0 ` 65,000 na 9.7 SEER Single Package Without a 65,000 , 135,000 10.3 EER n/a This schedule of equip- A Heating Section or With Electric 135,000 240,000 . 9.7 EER • n/a ment efficiencies was Resistance Heat 240,000 760,000• 9.5•EER 9.7 IPLV reformatted from code, 760,000 - 9.2 EER 9.4 IPLV Table 13 - L. 0 65,000 na 10 SEER Split System Without a Heating 65,000 . 135 10.3 EER , ' n/a B Section or With Electric 135,000 240,000 9.7 EER n/a Resistance Heat 240,000 760,000 9.5•EER 9.5 IPLV 760,000 - 9.2 EER ••9.2 IPLV 0 65,000 na 9.7 SEER • . Single•Package With a Heating 65,000 135,000 '10:1 EER n/a C Section Other Than Electric 135,000 240,000 9.5 EER n/a Resistance 240,000 760,000 9.3 EER 9.. :5 IPLV • 760,000 - 9.0 EER - 9.2 IPLV ;.,,A• ` 'i 0 65,000 na 10 SEER � Split System With a Heating 65,000 135,000 10.1 EER n/a • (, ; � .�, : D Section Other Than Electric 135,000 240,000 9.5 EER . n/a Resistance 240,000 760,000 9.3 EER 9.7 IPLV . %ash 760,000 - 9.0 EER 9.4 IPLV E. Condensing Unit Only 135,000. - 10.1 EER 11.2 IPLV 4 -11 • Compliance with OSSC, effective 01/01/05 Case Activity Listing 9/29/2008 CEL Case #: MEC2008 -00482 8:57:59AM Assigned Done Updated Activity Description Date 1 Date 2 Date 3 Hold Disp To By By Notes MEC1010 Application received 9/26/2008 None RECD DEB 9/26/2008 BLD MEC1020 Permit created 9/26/2008 None DONE DEB 9/26/2008 BLD MEC 1030 Check for parcel tags 9/26/2008 None DONE DEB 9/26/2008 BLD MEC1060 Building plans routed 9/26/2008 None DONE DEB 9/26/2008 to PE BLD n \' Page 1 of 1 CaseActivity..rpt �l Case Activity Listing 9/29/2008 CEL/ 8:57:59AM Case #: MEC2008 -00482 Assigned Done Updated Activity Description Date 1 Date 2 Date 3 Hold Disp To By By Notes MEC1010 Application received 9/26/2008 None RECD DEB 9/26/2008 BLD MEC1020 Permit created 9/26/2008 None DONE DEB 9/26/2008 BLD MEC1030 Check for parcel tags 9/26/2008 None DONE DEB 9/26/2008 BLD MEC1060 Building plans routed 9/26/2008 None DONE DEB 9/26/2008 to PE BLD • t Page 1 of 1 CaseActivity..rpt