Loading...
Plans o ci p e,U'7 00 00 Fire and Life Safety Inspection Checklist for Required Rated Assemblies ❑ Exterior Walls— 704 - Rated 1 2 3 4 ( inside > 5' Y N) Parapet Y N Openings protection Y N ❑ Fire Wall — 705 ❑ Party wall Y N (503.2) Parapet Y N Openings protected Y N • 705.5 Horizontal continuity. Fire walls shall be continuous from exterior wall to exterior wall and shall extend at least 18 inches (457 mm) beyond the exterior surface of exterior walls. "See Code book for exceptions" it.; 705.6 Vertical continuity. Fire walls shall extend from the foundation to a termination point at least 30 inches (762 mm) above both adjacent roofs. "See Code book for exceptions" ❑ Fire Barriers - 706 - Rated 1 2 3 4 Openings protected Y N 706.4 Continuity of fire barrier walls. Fire barrier walls shall extend from the top of the floor /ceiling assembly below to the underside of the floor or roof slab or deck above and shall be securely attached thereto. These walls shall be continuous through concealed spaces such as the space above a suspended ceiling. ❑Incidental use area Y N Sprinkled Y N Rated (1 hour) Y N 302.1.1.1 Separation. Where Table 302.1.1 requires a fire - resistance -rated separation, the incidental use area shall be separated fr', e remainder of the building with a fire barrier. Where Table 302.1.1 permits an automatic fire- extinguishing system without a • .. b.! :` "' the incidental use area shall be separated by construction capable of resisting the passage of smoke. The partitions shall extend t 'm •e floor to the underside of the fire- resistance -rated floor /ceiling assembly or fire- resistance -rated roof /ceiling assembly o ;s?- underside of the floor or roof deck above. Doors shall be self - closing or automatic - dosing upon detection of smoke Doors • all not have air Transfer openings and shall not be undercut in excess of the clearance permitted in accordance with NFPA ❑ Shaft Enclosures — 707 - Rated 1 2 3 4 Openings protected Y N 707.5 Continuity. Shaft enclosure walls shall extend from the top of the floor /ceiling assembly below ..,,, , a dersi • of the floor or roof slab or deck above and shall be securely attached thereto. These walls shall be continuous throu: • a • .� . ale ces such as the space above a suspended ceiling. The supporting construction shall be protected to afford the required , "-esist ce rating of the element supported. Hollow vertical spaces within the shaft enclosure construction wall shall be .:',, stoppe. `=;.. very floor level. Fire Partitions - 708 - Rate • EI 2 3 Openings protected �_;::. ~ • 70 Continui .Fire artitions sh. I extend from the to of the floor assembl be • - the ide of the floor or roof slab or ty P P y deck above or to the fire- resistance -rated floor /ceiling or roof /ceiling assembly abo : . `=•,. b- s ecurely attached thereto. If the s partitions are not continuous to the deck, and where constructed of combustible in ction " e space between the ceiling and the A deck above shall be fire- blocked or draft - stopped in accordance with Sections 17.'.1 7 7.3.1 at the partition line. ❑ Smoke Barriers — 709 — Rated 1 2 3 4 Openings •` ;;, • -, , 709.4 Continuity. Smoke barriers shall form an effective membran • continuo ' , om outside wall to outside wall and from floor slab to floor or roof deck above, including continuity through conceale sp. es, such as those found above suspended ceilings, and interstitial structural and mechanical spaces. The supporting co, • i :'k:w;" ' :.. be protected to afford the required fire- resistance rating of the wall or floor supported in buildings of other than T• . • I III: or ! : construction. ❑ Smoke Partition — 710 - Rated 1 2 Ope i'.: • protected Y N 710.4 Continuity. Smoke partitions shall extend fro •• ` I oor to the underside of the floor or roof deck above or to the underside of the ceiling above where the ceiling membrane ons li te'" o limit the transfer of smoke. ❑ Horizontal Assemblies — 711 - ' - • `r, 2 4 Openings protected Y N 711.4 Continuity. Assemblies shall be c. • tinu. s wi tut openings, penetrations or joints except as permitted by this section and Sections 707.2, 712.4 and 713. Skylights . ". "+• e' .•• netrations through a fire- resistance -rated roof deck are permitted to be unprotected, provided that the structural inte -. - of the fire- resistance -rated roof construction is maintained. - ❑ Membrane Penetrations — 712 ❑ Through Penetrations — 712 ❑ Fire Resistive Joint System — 713 ❑ Fire Resistive Rating of Structural Members — 714 ❑ Opening Protective — 715 ❑ Ducts & Air Transfer Openings — 716 - 716.4 Access and identification. Fire and smoke dampers shall be provided with an approved means of access, large enough to permit inspection and maintenance of the damper and its operating parts. ..Access points shall be permanently identified on the exterior by a label having letters not less than 0.5inch (12.7 mm) in height reading. SMOKE DAMPER or FIRE DAMPER. El Thickness of Protective Coverings — 720 -Table 720.1(1) ❑ Safety Glazing — 2406 El Other - I WALLS AND INTERIOR PARTITIONS, NONCOMBUSTIBLE) GA FILE NO. WP 1072 + 1 GENERIC I 1 HOUR 45 to 49 STC GYPSUM WALLBOARD, STEEL STUDS FIRE SOUND One layer 5 /e" type X gypsum wallboard or gypsum veneer base applied parallel or at right �TT r angles to each side of 3 steel studs 24" o.c. with 1" Type S drywall screws 8" o.c. at !All �, vertical joints and 12" o.c. at floor and ceiling runners and intermediate studs. a Joints staggered 24" on each side and on opposite sides. Sound tested with 31/z" glass fiber 1 1 1 AL friction fit in stud space. (NLB) Thickness: 4 " Limiting Height: Refer to Section IV Approx. Weight: 6 psf Fire Test: See WP 1200 (FM WP -45, 6- 19 -68; OSU T -1770, 8 -61; ULC 79T484, 79T500,79T497, 8- 12 -81, ULC Design W415) Sound Test: NRCC 816 -NV, 2 -3 -81 . GA FILE NO. WP 1073 I I PROPRIETARY t I • 1 HOUR 45 to 49 STC FIRE SOUND GLASS MAT GYPSUM BOARD, STEEL STUDS, GLASS FIBER INSULATION mosamisomenem ems' One layer 1 ' roprietary type X glass mat water- resistant gypsum backing board applied 1, r, /r„� litt'11,, j parallel to h side of 21/z" steel studs 16" o.c. with 1" Type S drywall screws 8" o.c. at oleos , _ �_ e _� 1► pi vertical joints and 12" o.c. at intermediate studs and wall perimeter. 3 glass fiber insulation, 0.52 'pcf, friction fit in stud space. Joints staggered 16" on,opposite sides and covered with 10 x 10 mesh glass tape and the Thickness: 3 adhesive. (N \ Limiting Height: Refer to manufacturer U\ PROPRIETARY GYPSUM BOARD _Approx. Weight: 5 psf G P Gypsum - 1 /2 Dens - Shield@ , F re Test: CTC 1897-1655, 1-11-88 yp ' Sound Test: See WP 1070 ' - (RAL TL69 -42, 10- 17 -68) .- . GA FILE NO. WP 1076. I 1 PROPRIETARY" 1. 1 HOUR 45 to 49 STC GYPSUM WALLBOARD, TEEL STUDS, FIRE SOUND GLASS FIBER INSUt TION , MINIE111111111111•11111111111 11111•111111•=1111111111111 One layer 5 /e" proprietary type X gypsum wallboard or gypsum veneer base applied parallel typ i, t iI to each side of 21 /z" steel studs 24" o.c. with 1 Typ 'S drywall screws 8" o.c. at wall i , A lp 1' �,� , � o perimeter and 12" o.c. at vertical joints and with 1 Type,S drywall screws 12" o.c. or continuous t /a" beads of adhesive at intermediate studs. 2 ".lass fiber insulation, 0.65 pcf, friction fit in stud space. ' Joints staggered 24" on opposite sides. (NLB) , ' Thickness: 3 PROPRIETARY GYPSUM BOARD Limiting Height: Refer to manufacturer BPB Canada Inc. - 5 /e" ProRocTM Type X G Panels Approx. Weight: 6 psf G -P Gypsum 5 /e ToughRock® Fireguard® Fire Test: ULC Design 1 -9 79, ULC Design W409 Sound Test: DRC 70 -2 -2, 1 -6 -70 GA FILE NO. WP 1081 I 1 PROPRIETARY/ ` 1‘`, 1 HOUR 45 to 49 STC GYPSUM WALLBOARD, STEEL STUDS \ \ FIRE SOUND • One layer 5 /e" proprietary type.X gypsum wallboard applied parallel to each side of 3 steel studs 24" o.c. with,/ "'Typa S drywall screws 8" o.c. at vertical joints and 12" o.c.` �, „ at floor and ceilinQ,runn¢rs and studs. Optional horizontal resilient channel 24" o.c applied :4o studs ' with one 1 /2" Type S -12 pan head screw at each stud in tersection. ,,, '� t . Stagger joints q each side and on opposite sides. Sound tested with 3" mineral fiber, 2.5 pcf, in stu pa (NLB) Thickness: e" /00e PROPRIETARY GYPSUM BOARD Limiting Height: Re to Section IV Approx. Weight 5 psf G -P Gypsum - 5 /e" ToughRock® Fireguard® Fire Test: R131 94NK40598, Lafarge North America Inc. - 5 /e Firecheck@ 11- 30 -94, United States Gypsum Company - 5 /e" SHEETROCK® Brand UL Design U 5 Abuse - Resistant Gypsum Panels Sound Test: USG - 960709, 7- 18 -96; RAL -TL99 -103, 6- 28 -99; . RAL -TL99 -160, 9 -3 -99 GA- 600 -2003 t Contact the manufacturer for more detailed information on proprietary products. 33