Permit �- = CITY Y OF TIGARD BUILDING PERMIT
IN PERMIT #: BUP2007 -00250
A' COMMUNITY DEVELOPMENT DATE ISSUED: 5/7/2007
TIOR 13125 SW Hall Blvd., Tigard, OR 97223 503.639.4171
PARCEL: 1S12600-00300
SITE ADDRESS: 09402 SW WASHINGTON SQUARE RD ZONING: C - G
SUBDIVISION: WASHINGTON SQUARE LOT: JURISDICTION: TIG
PROJECT: DICK'S SPORTING GOODS
Project Description: Underground fire protection service.
REISSUE: FLOOR AREAS EXTERIOR WALL CONSTRUCTION
CLASS OF WORK: FPS FIRST: sf N: S: E: W:
TYPE OF USE: COM SECOND: sf PROJECT OPENINGS?
TYPE OF CONST: 2N sf N: S: E: W:
OCCUPANCY GRP: M TOTAL AREA: 0 sf ROOF CONST: FIRE RET?
OCCUPANCY LOAD: BASEMENT: sf AREA SEP. RATED:
STOR: HT: ft GARAGE: sf OCCU SEP. RATED:
BSMT ?: MEZZ ?: REQD SETBACKS REQUIRED
FLOOR LOAD: psf LEFT: ft RGHT: ft FIR SPKL: SMOK DET:
DWELLING UNITS: FRNT: ft REAR: ft FIR ALRM : HNDICP ACC:
BEDRMS: BATHS: IMP SURFACE: PRO CORR: PARKING:
VALUE: $ 3,500.00
Owner: Contractor:
WASHINGTON SQUARE LLC COSCO FIRE PROTECTION INC.
BY THE MACERICH COMPANY 11800 NE 95TH ST #240C
9585 SW WASHINGTON SQUARE RD VANCOUVER, WA 98682
TIGARD, OR 97223
Contact #: PRI 360 - 883 -6383
Phone: FAX 360- 883 -6390
Reg #: LIC 67508
FEES
Description Date Amount REQUIRED ITEMS AND REPORTS
[BUILD] Permit Fee 5/3/2007 $81.70
[TAX] 8% State Surcharl 5/3/2007 $6.54
[FLS] FLS Pln Rv 5/3/2007 $32.68
Total $120.92
This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable
law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work
is sus nded- fef-••ore than 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification
liter. Those rules ar- et forth in OAR 952 - 001 -0010 through OAR 952 -001 -0100. You may obtain a copy of these rules or direct questions
to OUNC by calling 503i •t or 1.800.332.2344.
Issued By: /% AI i � Permittee Sign ture: _, r ed ---`—)
Call 503.639.4175 by 7:00 a.m. for an inspection that business day.
This permit card shall be kept in a conspicuous place on the job site until completion of the project.
Approved plans are required on the job site at the time of each inspection.
-l2� _L -lDV
1 G ..
Building Permit Application FOR OFFICE. USE ONLY
lihi .. City of Tigard �D Date/By: �iv/03 $8 Permit No. e ?Q0_ p� 5-0 a 13125 SW Hall Blvd., Tigard, OR ' .1=�C EN� Plan Review
Phone: 503.639.4171 Fax: 503.5' ), `J Date/By: r"A 1/ - 7 - O 7 Other�e it:
Ins ection Line: 503.639.4175 2007 Date Read B / Jyr(s EI See Attached Checklist for
TIGARD
p M —3 y
Internet: www.tigard- or.gov Notified/Methoo
d: ,49 Supplemental Information
D p p � 1 �
TYPE Or ' REQUIRED DATA: 1- AND 2- FAMILY DWELLING
® New construction ❑ Demolition Permit fees* are based on the value of the work performed.
Indicate the value (rounded to the nearest dollar) of all
❑ Addition/alteration/replacement ❑ Other: equipment, materials, labor, overhead, and the profit for the
CATEGORY OF CONSTRUCTION work indicated on this application.
❑ 1- and 2- family dwelling ® Commercial /industrial
Valuation: $N /A
❑ Accessory building ❑ Multi - family Number of bedrooms:
❑ Master builder ❑ Other: Number of bathrooms:
JOB SITE INFORMATION AND LOCATION Total number of floors:
Job site address: 9402 Washington Square Road New dwelling area: square feet
City /State /ZIP: Tigard Oregon 97223 Garage /carport area: square feet
Suite/bldg. /apt. no.: Project name: Dick's Sporting Goods Covered porch area square feet
Cross street/directions to job site: Washington Square Mall Deck area: square feet
Other structure area: square feet
REQUIRED DATA: COMMERCIAL -USE CHECKLIST
Subdivision: I Lot no.: Permit fees* are based on the value of the work performed.
Indicate the value (rounded to the nearest dollar) of all
Tax map /parcel no.: equipment, materials, labor, overhead, and the profit for the
DESCRIPTION OF WORK work indicated on this application.
Supply Underground fire service from 5' -0" outside face of building Valuation: $$3,500.00
to a flange 6" above finished floor Existing building area square feet
New building area: square feet
❑ PROPERTY OWNER I 0 TENANT Number of stories:
Name: Dick's Sporting Goods Type of construction:
Address: 9402 Washington Square Road Occupancy groups:
City /State /ZIP: Tigard, Oregon Existing:
Phone: ( ) Fax: ( ) New:
0 APPLICANT ❑ CONTACT PERSON NOTICE
Business name: Cosco Fire Protection All contractors and subcontractors are required to be
Contact name: Nick Stalkup licensed with the Oregon Construction Contractors Board
under ORS 701 and may be required to be lensed in the
Address: 11800 Ne 95 street jurisdiction in which work is being performed. If the
City /State /ZIP: Vancouver, Washington 98682 applicant is exempt from licensing, the following reasons
apply:
Phone: (360) 883 -6383 Fax: : (360) 883-6390
E -mail: nicks @coscofire.com
CONTRACTOR
Business name: Cosco Fire Protection BUILDING PERMIT FEES*
Address: 11800 Ne 95 street
(Please referrojeeschedute)
Structural plan review fee (or deposit):
City /State /ZIP: Vancouver, Washington 98682
Phone: (360) 883 -6383 Fax: (360) 883 -6390 FLS plan review fee (if applicable):
CCB lic.: 67508 p 9 Total fees due upon application:
�i -'14o
Amount received:
Authorized signature: � Z� This permit application expires if a permit is not obtained
within 180 days after it has been accepted as complete.
Print name: NICK STALKUP Date: 5/03/07 * Fee methodology set by Tri- County Building Industry
Service Board
1 : \ Building \Permits\BUP- PermitApp.doc 03/21/06 440- 4613T(1 I /02JCOM/WEB)
CITY OF TIGARD
BUILDING DIVISION PERMIT #: 13UP7OO7- 0UM
13125 SW Hall Blvd., Tigard, OR 97223 DATE ISSUED: 5/ r/a10ft7
Phone: (503) 639 -4171 �"' =yi +c � .k
_ _
Inspection Requests (24 Hrs.): (503) 639 -4175 '" I l l
INSPECTION WORKSHEET FOR DATE: 1/22/70 TIME: 7 :01AM PAGE: 4
SITE ADDRESS: 09402 SW WASHINGTON SQUARE RD CLASS OF WORK:
SUBDIVISION: WASHINGTON SQUARE LOT #: TYPE OF USE:
PROJECT NAME: DICK'S SPC.)RTING GOODS
DESCRIPTION: Undercxound fire protection service.
OWNER: WASHINGTON SQUARE. LLC, PHONE #:
CONTRACTOR: COSCO FIRE PROTECTION INC. PHONE #: 360-883-6383
Inspection Request Scheduled For: Date: 1/22/2008 Pour Time:
Code # Inspection Description Confirm # Contact # Messa..e
999 faprinklor final 0€.3649 01 503-709 4
Corrections /Comments/ Instructions:
•
0 MARTIAL APPROVAL ❑ CANCEL ❑ NO ACCESS
II AIL % CALL FOR INSPECTION ❑ ADDITIONAL FEES ASSESSED
Inspector: / Date: / Z Og Phone #: (503) 718 - C g,1
CITY ��U~��� �����~N��������
��m� mm��a���m�� _
BUILDING ��U��U��U���� �� ' ^
~°~,,°~~°,,°~� ~°,°,~,,~~,° PERMIT #: EK)P200700260
13125 SW Hall Blvd., Tigard, OR 97223 DATE ISSUED: 6/7Y2007
Phone: (503) 639-4171 At ' V`,
Inspection Requests (24 Hrs.): (503) 639-4175 .. "�1.
INSPECTION WORKSHEET FOR DATE: 1/17/2008 TIME: 7:1XUAk4 PAGE: 35
SITE ADDRESS: C4O2 SW WASHINGTON SOUARE RD CLASS OF WORK:
SUBDIVISION: WASHINGTON SQUARE LOT #: TYPE OF USE:
PROJECT NAME: DICK'S SPORTING GOODS
DESCRIPTION: Undw/ground protection swim.
OWNER: WASHINGTON SOUARE LLC, PHONE #:
CONTRACTOR: MSC0 FIRE PROTECTION INC. PHONE #: 350-885-8383
Inspection Request Scheduled For: ' Date: 1/17/2008 Pour Time: .
Code # Inspection Description Confirm # Contact # Message
993 SminNerTinal 065420-01 503'709-2793 N
Corrections/Comments/Instructions:
/� - 71 ^r �� �� Ali w" °' ��,,/
. ------
1 PA S ' ~ART|ALAPPROVAL ] CANCEL NO ACCESS
CALL FOR INSPECTION 7 ADDITIONAL FEES ASSESSED
/
_____GZ
Inspector:
....--c::=''' Date: / / 7 025 Phone #: (503) 718-
._a
CITY OF TIGARD •
BUILDING DIVISION PERMIT #: EiUP2007- 002.50
13125 SW Hall Blvd., Tigard, OR 97223 DA ISSUED: 5/7/2007
Phone: (503) 639 -4171
Inspection Requests (24 Hrs.): (503) 639 -4175 s 1 L
INSPECTION WORKSHEET FOR DATE: 5/17/2007 TIME: 7:00AM PAGE: 80
SITE ADDRESS: 03402 SW WASHINGTON SQUARE RD CLASS OF WORK:
SUBDIVISION: WASHINGTON SQUARE LOT #: TYPE OF USE:
PROJECT NAME: DICK'S SPORTING GOODS
DESCRIPTION: Underground fire protection service.
OWNER: WASHINGTON SQUARE LLC, PHONE #:
CONTRACTOR: COSCO FIRE PROTECTION INC. PHONE #: 360 -883- 638:3
Inspection Request Scheduled For: Date: 5/17 /2007 .iti4" Pour Time:
Code # Inspectio Description Confirm # Contact # Me age
410 Fill �,Q 048422 -01 360 -8133 -6383 Y
Corrections /Comments /Instructions: • 655k
- 1.,) ( 9 LIAJP--
Q t ' -
PASS 0 "ARTIAL APPROVAL n CANCEL n NO ACCESS
FAIL ❑ CALL FOR INSPECT ON ADDITIONAL FEES ASSESSED
Inspector: Date: � I Phone #: (503) 718 - 2'4
05/03/2007 15:9 3608836390
COSCO FIRE PROTECT. PAGE 02
‘
.imel$6 .e 42 ' . ‘ 214 0 eaAn
c--. ......_
1-A4LL Cr•-?_-S----c-j)
7 ." ‘4t„V.2t7:4
i : trzr--.c,e::) rvwx,..,..\-A.7. c-.■ -al
1 .
_ ... . 7 IstitKmr,r st
- \ - -
cvy‘L
L._
, —1
.- te3 4
i - 1 -
a as 4 4
_ 1
. 2 ..- Cc:ic‘<,.
,
4 3
-- a
1 0
a il ki, ,
_ . . ......._
$ ,
CITY OF TIGARD
Approved qft X" IC er f Ta-' e-,.. , [ K . / •
conditionally Approved I l
For only the work as described in:
PE9MIT --
NO.
See Letter to:
Atach -) 1 (1
Job Adkrer7U 52) 4 /"I ' S i 1 ---- 1 L
- .,
B:,_ Da • ....
reE, "?..\'e--Ne-
---- -L-- - - , 1 ‘ " — t -
OFFICE COPY
m
i •-._N-v-c., lip mac'°
N
0 J
U q
i in 1
� _1 ck
I 4_ ‘717. : 7 _______ 7: 1 (SZ. - - - - .
• �I -
:0 —161C \ Vtas,v
m 1
— l,S.t - 77VA AFL
CO m 00 ( � i E �• e5 Cy o4
m r - .�- __ - - —
4 0 1 b _ -
co
1 _
c n t 'i P, G K �i,
0
I l
-�- t.. l..1...--. caZJ 7 LocV.
m
CD --- - 71 L11� --C ` -Q , .- . _
m
m —
_ V
05/03/2007 15:09 3608836390 COSCO FIRE PROTECT. PAGE 04
•
eve' Zo 7
j 'Yr 1 _ r■ a. O rr A' i.<Yli IN ■MI sasaa •10
' . rims, `a , , ' 1sv�rt
\ ' . s ~• K TOP VIEW
TOP TOP EW
'a WYE
SIDE VIEW ' <�� /' /•/ \' A �■ \'/
SIDE VIEW • .. . .. /
SIDE VIEW
TEE CROSS GATE VALVE HORIZ. BEND
•
\ jam . . { \ ..e.../ :1.0 , %. j. • ,: ;�• t �t .,
. rm. 11, Wil-.r: . r r i ,rrrDi. " ' �\
TEE WITH CROSS WITH CROSS WITH PLUG OR CAP
PLUG PLUG PLUGS
. .� ,• /: r�.„� \ HATES: •
A� �4/ 1. CONCRETE THRUST BLACKING TO BE
� POURED AGAINST UNDISTURBED EARTH.
-..-'..;:°""..;' / 2. PLASTIC BARRIER SHALL BE. PLACED
N' '.'" .s,. � TWEEN, AU. 'THRUST BLOCKS & FITTINCS.
45' `` — SO 3 . BASEMENT, #5 ON 6 BE 4 8 DIAMETER NIT AND " BASEMENT. Ca
VERTICAL BEND 4. PLUGS TO BE MINIMUM OF 5' FROM
TEE. WYE. CROSS ON VALVE.
1
STANDARD BLOCKING DETAIL
N.T.S MI6': 6 -14
•
05/03/2007 15:09 3608836390 COSCO FIRE PROTECT. PAGE 05
6u ( 206 �
�C Z
THRUST LOADS
THRUST AT FITflNOS IN POUNDS AT 200 POUNDS PER SQUARE INCH OF WATER PRESSURE
PIPE 90' BEND 45' BEND 22.1/2 BEND 11 -1/4• BEND DEAD END
DIAMETER OR TEE
4" 3,600 2,000 1,000 500 2,600
6 8,000 4,400 2,300 1,200 5,700
B" 14,300 7,700 4,000 2,000 10,100
10" 22,300 12,100 6,200 3,100 15,800
12 32,000 17,400 8,900 4,500 22,700
14" 43,600 23,600 12,100 6.100 30,800
16" 57,000 30,600 15,700 7,900 40,300
NOTES:
1. BLOCKING SHALL BE CEMENT CONCRETE CLASS "5" POURED IN PLACE
AGAINST UNDISTURBED EARTH. FITTING SHALL BE ISOLATED FROM CONCRETE
THRUST BLOCK WITH PLASTIC OR SIMILAR MATERIAL.
2. TO DETERMINE THE BEARING AREA OF THE THRUST BLOCK IN SQUARE
FEET (S.F.):
EXAMPLE : 12" - 90' BEND IN SAND AND GRAVEL
32,000 LDS + 3000 Le /S.F. = 10.7 S.F. OF AREA
3. AREAS MUST BE ADJUSTED FOR OTHER PIPE SIZE, PRESSURES AND
SOIL CONDITIONS.
4. BLOCKING SHALL BE ADEQUATE TO WITHSTAND FUU. TEST PRESSURE
AS WELL AS TO CONTINUOUSLY WITHSTAND OPERATING PRESSURE UNDER
AU. CONDITIONS OF SERVICE.
SAFE SOIL BEARING LOADS
FOR HORIZONTAL THRUSTS WHEN TIE DEPTH
OF wan OVER THE PIPE EXCEED$ 2 FEET
SOIL POUNDS PER
SQUARE FOOT
MUCK, PEAT 0
SOFT CLAY 1,000
SAND 2.000
gSgA�NpD & GRAVEL 3.000
CEMENTED W HL 4,000
CLAY
HARD SHALE 10,000
MUST LOAD'S
N.T..& D$ 8 -15
t OC) 2 7 - c Z
COSCO Contractor's Material Test Certificate for Underground Piping
:•••..•:
rut-Protection
PROCEDURE
Upon completion of work, inspection and tests shall be made by the contractor's representative and witnessed by an owner's representative. All defects
shall be corrected and system left in service before contractors personnel finally leave the job.
A certificate shall be filled out and signed by both representatives. Copies shall be prepared for approving authorities, owners, and contractor. It is
understood the owner's representative's signature in no way prejudices any claim against contractor for faulty material, poor workmanship, or failure to
comply with approving authority's requirements or local ordinances.
Property Name Date
Dick's Sporting Goods 1/15/08
Property Address
9402 Washington Square Road, Tigard, Oregon 97223
Accepted by Approving Authorities (names)
Address
Plans Installation conforms to accepted plans ❑O Yes ❑ No
Equipment used is approved 0 Yes ❑ No
If no, explain deviations
Has person in charge of fire equipment been instructed as to location ❑O Yes ❑ No
of control valves and care and maintenance of this new equipment?
If no, explain.
Instructions Have copies of appropriate instructions and care and maintenance ❑x Yes ❑ No
Charts been left on premises?
If no, explain
Location Supplies Buildings
9402 Washington Square Road, Tigard, Oregon 97223
Pipe types and class Type joint
Ductile Iron Class 52 Mega -Lug
Pipe conforms to NFPA Standard 0 Yes ❑ No
Underground Fittings conforms to NFPA Standard 0 Yes ❑ No
If no, explain
Pipes and
Joints Joints need anchorage clamped, strapped, or blocked in ❑x Yes ❑ No
accordance with NFPA Standard
If no, explain
Flushing: Flow the required rate until water is clear as indicated by no collection of foreign material in burlap bags at outlets
such as hydrants and blow -offs. Flush at flows not less than 390 gpm (1476 Umin) for 4 -in. pipe, 880 gpm (3331 Umin) for
6 -in. pipe, 1560 gpm (5905 Umin) for 8 -in. pipe, 2440 gpm (9235 Umin) for 10 -in. pipe, and 3520 gpm (13,323 Umin) for 12-
in. pipe. When supply cannot produce stipulated flow rates, obtain maximum available.
Hydrostatic: Hydrostatic tests shall be made at not less than 200 psi (13.8 bar) for 2 hours or 50 psi (3.4 bar) above static
Test pressure in excess of 150 psi (10.3 bar) for 2 hours.
Leakage: New pipe laid with rubber gasketed joints shall, if the workmanship is satisfactory, have little or no leakage at the
Description joints. The amount of leakage at the joints shall not exceed 2 quarts per hour (1.89 Uhr) per 100 joints irrespective of pipe
diameter. The leakage shall be distributed over all joints. If such leakage occurs at a few joints, the installation shall be
considered unsatisfactory and necessary repairs made. The amount of allowable leakage specified above can be increased
by 1 fluid ounce per inch valve diameter per hr. (30 mU25 mm /hr) for each metal seated valve isolating the test section. If
dry barrel hydrants are tested with the main valve open so the hydrants are under pressure, an additional 5 ounces per
minute (150 mUmin) leakage is permitted for each hydrant.
OFFICE c RECEW E
IA 11 232008
CITY Ur i IIaHUD
BUILD1NGDWVISION
._ �. ou 2,0i -do g
New underground piping flushed according to 0 Yes ❑ No
_ NFPA 13 Standard by Cosco Fire Protection. r
If no, explain
How flushing flow was obtained Through what type opening
Flushing x❑ Public Water ❑ Tank or Reservoir ❑ Fire Pump ❑ Hydrant Butt ❑x Open Pipe
Tests Lead -ins flushed according to NFPA 13 Standard 0 Yes ❑ No
by Cosco Fire Protection.
If no, explain
How flushing flow was obtained Through what type opening
x❑ Public Water ❑ Tank or Reservoir ❑ Fire Pump ❑ Y connection to flange 0 Open Pipe
and spigot
Hydrostatic All new underground piping hydrostatically tested at Joints covered
Test 200 PSI for 2 hours ❑x Yes ❑ No
Total amount of Leakage measure
gallons hours
Leakage
Test Allowable leakage
gallons hours
Hydrants Number installed Type and make All operate satisfactorily
❑ Yes ❑ No
Water control valves left wide open ❑ Yes ❑ No
Control If no, state reason
Valves Hose threads of fire department connections and hydrants interchangeable with
0 Yes ❑ No
those of fire department answering alarm
Date left in service
Remarks 1/15/08
Name of installing contractor Contractors License No.
Cosc Fire Pro Lion 64508
1 ---Casts witnessed by
.91F erty owner (signs t Title Date
Signatures `' /. c, T/ v / -..2./- o 6
0 kler contractor (sign - -° -- - Title Date
• at - •proving authorit" (1- • Tilled Date g p.
1 ....., J .„,
Additional explanations and notes