Permit CITY OF TI GARD BUILDING PERMIT PERMIT #: BUP2006 -10044 A Ij DEVELOPMENT SERVICES DATE ISSUED: 6/15/2006 13125 SW Hall Blvd., Tigard, OR 97223 503 - 639 -4171 PARCEL: 2 S 113AC -00103 SITE ADDRESS: 07244 SW DURHAM RD M900 ZONING: I -P SUBDIVISION: PACTRUST BUSINESS CENTER LOT: JURISDICTION: TIG Project Description: TI - walls.(7,831 sq ft area = 2,540 B, 5,291 S2) REISSUE: FLOOR AREAS EXTERIOR WALL CONSTRUCTION CLASS OF WORK: ALT FIRST: sf N: S: E: W: TYPE OF USE: COM SECOND: sf PROJECT OPENINGS? TYPE OF CONST: 3N : sf N: S: E: W: OCCUPANCY GRP: B TOTAL AREA: 0 sf ROOF CONST: FIRE RET? OCCUPANCY LOAD: 44 BASEMENT: sf AREA SEP. RATED: STOR: 1 HT: ft GARAGE: sf OCCU SEP. RATED: BSMT ?: MEZZ ?: REQD SETBACKS REQUIRED FLOOR LOAD: psf LEFT: ft RGHT: ft FIR SPKL: SMOK DET: DWELLING UNITS: FRNT: ft REAR: ft FIR ALRM : HNDICP ACC: BEDRMS: BATHS: IMP SURFACE: PRO CORR: PARKING: VALUE: $ 2,500.00 Owner: Contractor: PACIFIC REALTY ASSOCIATES A J WEBER CONSTRUCTION INC 15350 SW SEQUOIA PKWY #300 -WMI PO BOX 80548 PORTLAND, OR 97224 PORTLAND, OR 97280 Phone: Contact #: PRI 503 - 244 -4318 FAX 503 - 244 -4318 FEES Reg #: LIC 65238 Description Date Amount REQUIRED ITEMS AND REPORTS [BUILD] Permit Fee 6/14/2006 $72.10 [TAX] 8% State Surchari 6/14/2006 $5.77 [BUPPLN] Pln Rv 6/14/2006 $46.87 [FLS] FLS Pin Rv 6/14/2006 $28.84 Total $153.58 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more than 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952 -001 -0 .through OAR 952 - 001 -0100. You may obtain a copy of these rules or direct questions to OUNC by calling 3-246=6.! ' ,fik -800- 332 -2344. Issue y:. `' m Permittee Signa . • . da' (JJllr/tA---L.- Call 503 - 639 -4175 by 7:00 a.m. for an inspection that business day. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. Building Permit Application FOR OFFICE USE ONLY City of Tigard Received / g Date/By: (� It;, Permit No.: k- r�® �� _ �cf, 13125 SW Hall Blvd., Tigard, OR 97223 Plan Revi Phone: 503.639.4171 Fax: 503.598.1960 ' h l(��'i�'' DateB � l Other Permit: / . . Inspection Line: 503.639.4175 "-...• Date Ready/By: El See Attached Checklist for Internet: www.ci.tigard.Or.us Notified/Method: Supplemental Information REQUIRED DATA: 1- AND 2-FAMILY DWELLING .; ± � ,. � ... ,r s,'n TYPE' °OF WQ RK Q ❑ New construction ❑ Demolition Permit fees* are based on the value of the work performed. Indicate the value (rounded to the nearest dollar) of all Addition/alteration/replacement ❑ Other: equipment, materials, labor, overhead, and the profit for the n� y i o, yli'',:i � � ^���.6s t - ai i work indicated on this application. U. l4 J '3Wr:l Z., i4.4.,� ?^ IOdr 11 5 *. 3 QWAV 4s4 .10 ` 4 .4 : i : t 'ri t &{h� .. d .i ❑ 1- and 2- family dwelling ommercial/industrial - Valuation: $ ❑ Accessory building ❑ Multi- family Number of bedrooms: ❑ Master builder ❑ Other: Number of bathrooms: • dri t .. 4 'S➢e r *iku° r I n w raw ,++" i , �.i t r, F dd,, a J�f .rv:,. l Q , {t �� o g � ®, e 4 r ��` Total number of floors: Job site address: - 7 2- 1 s-,,,...) a ,e.- Lla(A./t P.cf , New dwelling area: square feet City/State /ZIP: f tC Q [ 7 2 2-J-( Garage /carport area: square feet Suite/bldg. /apt. nod e9D Project / name: r Pi t,1_,511 n P/4 L , Covered porch area: square feet Cross street/directions to job site: S (-J.- ri (lam( — Deck area: square feet p .t & f "7244 4 Other structure area: square feet REQUIRED DATA: COMMERCIAL -USE CHECKLIST Subdivision: Lot no.: Permit fees* are based on the value of the work performed. Indicate the value (rounded to the nearest dollar) of all Tax map /parcel no.: equipment, materials, labor, overhead, and the profit for the ESCRIPTTON OFD - ORK work indicated on this application. i "1 1 ( S Dl70,/ / /1�l /S Valuation: $ �� j CEO. Do (� f � . � 1/1j," wD V. 11 Viii-L- / � Existing building area: � io 3 square feet t2 vv4 � 1 f f l r � �� �� u�� S ,Q 0 New building area: 7 l D2 square feet j p P I ' AOW ER l h 0 5 c i+ �r ` Number of stories: (� Name: PacTrust Type of construction: ) l l' Address: 15350 SW Sequoia Pkwy. , Suite 300 Occupancy groups: City/State /ZIP: Portland, OR 97224 Existing: 13/5. 2 Phone: 603 ) 624-6300 Fax ( 503) 624-7755 New: 3/S: ],.APPLICANT ❑: ; CONTACT PERSO l ..._, _ ,N Business name: PacTrust All contractors and subcontractors are required to be Contact name: licensed with the Oregon Construction Contractors Board under ORS 701 and may be required to be licensed in the Address: 15350 SW Sequoia Pkwy., Suite 300 jurisdiction in which work is being performed. If the applicant is exempt from licensing, the following reasons City/State /ZIP: Portland, OR 97224 apply: Phone: ( 503) 624 - 6300 Fax: : ( 503 ) 624 - 7755 E -mail: CONTRACTOR k Business name: AJ Weber Construction, Inc. BUILDI PERMIT FEES* Address: PO Box 80548 Please refer to fee schedule. City/State /ZIP: Portland, OR 97280 Fees due upon application Phone: ( 503) 244 - 4318 i Fax: (503 244 - 4318 Amount received CCB lic.: 65238 Date received: Authorized signature: / / This permit application expires if a permit is not obtained within 180 days after it has been accepted as complete. Print name: /14. }-- � Date: // l / w * Fee methodology set by Tri- County Building Industry / 1 l `/ Service Board. i:\ Building \Permits \BUP- PermitApp.doc 12/03 440- 4613T(II /02/COM/WEB) CITY OF TIGARD ' BUILDING DIVISION PERMIT #:Z00 — 03 13125 SW Hall Blvd., Tigard, OR 97223 DATE ISSUED: Phone: (503) 639 -4171 Inspection Requests (24 Hrs.): (503) 639 -4175 '''---• INSPECTION WORKSHEET FOR DATE: 7(z7( TIME: PAGE: SITE ADDRESS: 7 ', 0l OD CLASS OF WORK: SUBDIVISION: LOT #: TYPE OF USE: PROJECT NAME: DESCRIPTION: OWNER: Sr PHONE #: CONTRACTOR: /; Oe ?,� PHONE #: Inspection Request Scheduled For: Date: Pour Time: Code # Inspection Description Confirm # Contact # Message Hviitsce-- z_14-1 Corrections/Comments/Instructions: _ 1 ( ,i),---ikt.7 Wli I PASS PARTIAL APPROVAL CANCEL NO ACCESS I I FAIL CALL FP INSPECTION ADDIT ONAL FEES ASSESSED + ,ir ,fly Inspector: Date: v • Phone #: (503) 718 - CITY OF TIGARD BUILDING DIVISION PERMIT #: BL't'200(h I 0(Y14 13125 SW Hall Blvd., Tigard, OR 97223 DATE ISSUED: 6t1612.00G Phone: (503) 639 -4171 - ,4 11 Inspection Requests (24 Hrs.): (503) 639 -4175 , ' Ail INSPECTION WORKSHEET FOR DATE: 7/ 11/2006 / '� !" ' " '' `' PAGE: SITE ADDRESS: 0/2'14 SW DURHAM RD M900 CLASS OF WORK: SUBDIVISION: PACTRUST BUSINESS CENTER R LOT #: TYPE OF USE: PROJECT NAME: FORMS PLUS INC DESCRIPTION: I - wlalls.(7,831 sq ft area a, 2,510 B, 5,291 S2) OWNER: PACIFIC REALTY ASSOCIATES, PHONE #: CONTRACTOR: A J WEBER CONSTRUCTION INC_ PHONE #: 503- 244" "4318 Inspection Request Scheduled For: Date: 7/11/200G Pour Time: Code # Inspection Description Confirm # Contact # Message :,' , I a ;; iiiq 032904 -01 503.320-B501 Y Y Corrections /Comments /Instructions: CAL(- ED Iflzz- I so itA+m i .k)T ! n . 1 ,// - ,A A ••'";""" WOW ' PAS I I PARTIAL APPROVAL CANCEL NO ACCESS FAIL CALL FOR INSPECTION 1 I ADDITION ' FEES ASSESSED f Inspector: Date: 7 i i 4 Phone #: (503) 718 - > I CITY OF TIGARD BUILDING DIVISION PERMIT #: BUP2005- 10044 13125 SW Hall Blvd., Tigard, OR 97223 DATE ISSUED: 6 /151200G Phone: (503) 639 -4171 �0 N Inspection Requests (24 Hrs.): (503) 639 -4175 .' - —. INSPECTION WORKSHEET FOR DATE: 7012/2006 TIME: 7 . 04 '"'' b PAGE: 2 SITE ADDRESS: 0/244 SW DURHAM RD M900 CLASS OF WORK: SUBDIVISION: PACTRUCT BUSINESS CENTER LOT #: TYPE OF USE: PROJECT NAME: FORMS PLUS INC DESCRIPTION: TI - m11847,831 sq ft area = 2,540 B, 5,291 S2) OWNER: PACIFIC REALTY ASSOCIATES PHONE #: CONTRACTOR: A J WEBER CONSTRUCTION INC PHONE #: 5032'14.4318 Inspection Request Scheduled For: Date: 7/12/2006 Pour Time: Code # Inspection Description Confirm # Contact # Message r F I:-n ottv4 ti e a;f:? 1 . 01 fj( .. ' O. C Corrections /Comments /Instructions: �t i 0,) AGA: wir A - - - - - V . \,- . ..(''J k PASS H PARTIA APPROVAL 1 I CANCEL NO ACCESS FAIL [ I CALL FOR INSPECTION ADDITIONAL FEES ASSESSED Inspector: Date: 7 ` 66 Phone #: (503) 718- �42 r 2c64., o qy Diin �� j. April 10, 2006 CITY OF TIGARD OREGON American Heating Inc. Ken Mckinley 1339 SE Gideon St Portland, OR 97202 RE: ADDING COOLING COILS/ECONOMIZER + DUCT WORK - MECHANICAL SYSTEM Project Information Building Permit: MEC2006 -10044 Construction Type: unk Tenant Name: St. Anthony's Church Occupancy Type: A Address: 9905 SW McKenzie St. Occupant Load: unk Area: unk Stories: 2 The plan review was performed under the State of Oregon Mechanical Specialty Code (OMSC) to 2004 edition. The submitted plans are approved subject to the following. 1. Equipment and appliances shall be installed as required by the terms of their approval, in accordance with the conditions of the listing, the manufacturer's installation instructions and this code. Manufacturer's installation instructions shall be available on the job site at the time of inspection. OMSC 304.1 2. The building or structure shall not be weakened by the installation of mechanical systems. Where floors, walls, ceilings or any other portion of the building or structure are required to be altered or replaced in the process of installing or repairing any system, the building or structure shall be left in a safe structural condition in accordance with the Building Code. The cutting, notching and boring of framing members shall comply with OMSC 302 Sections 302.3.1 through 302.5.3. 3. Under floor spaces containing appliances requiring access shall be provided with an access opening and unobstructed passageway large enough to remove the largest appliance. The passageway shall not be less than 30 inches high and 22 inches wide, nor more than 20 feet in length measured along the centerline of the passageway from the opening to the appliance. OMSC 306 4. A lighting fixture controlled by a switch located at the required passageway opening and a receptacle outlet shall be provided at or near the appliance location in accordance with the Electrical Code. OMSC 306 5. Appliances installed in pits or excavations shall not come in direct contact with the surrounding soil. The sides of the pit or excavation shall be held back a minimum of 12 inches from the appliance. 13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 TDD (503) 684 -2772 `ec /oG Where the depth exceeds 12 inches below adjoining grade, the walls of the pit or excavation shall be lined with concrete or masonry. Such concrete or masonry shall extend a minimum of 4 inches above adjoining grade and shall have sufficient lateral load - bearing capacity to resist collapse. The appliance shall be protected from flooding in an approved manner. OMSC 303 1 6. Ducts shall be supported with approved hangers at intervals not exceeding 10 feet or by other approved duct support systems designed in accordance with the Building Code. Flexible and other factory -made ducts shall be supported in accordance with the manufacturer's installation instructions. OMSC 603.10 7. Metallic Ducts shall be supported in accordance with Sheet Metal & Air Conditioning Contractors National Association, Inc. (SMACNA) = Metal and Flexible. OMSC 603.4 8. Smoke detectors shall be installed in return air systems with a design capacity greater than 2000 cfm. Upon activation, the smoke detector shall shut down the air distribution system. Smoke detectors shall be connected to a fire alarm system and shall activate an audible and visible alarm at a constantly attended location. OR In occupancies not required to be equipped with a fire alarm system, actuation of a smoke detector shall activate a visible and an audible signal in an approved location. OMSC 606. 9. Every refrigerant system that shall be tested and proved tight after complete installation, and • before operation. Tests shall include both the high- and low- pressure sides of each system at not less than the lower of the design pressures or the setting of the pressure relief device(s). The design pressures for testing shall be those listed on the condensing unit, compressor or compressor unit name - plate, as required by ASHRAE 15. 1108.1 OMSC 10. Where vibration isolation of equipment and appliances is employed, an approved means of supplemental restraint shall be used to accomplish the support and restraint. OMSC 301.10 11. Equipment and appliances regulated by this code requiring electrical connections shall have a positive means of disconnect in accordance with the Electrical Code. OMSC 301.7 12. Appliances shall be accessible for inspection, service, repair or replacement without removal of . permanent construction. OMSC 306.1 13. Condensate from cooling coils or evaporators shall be collected and discharged to an approved plumbing fixture or disposal area. OMSC 307.1 Mercury Thermostats. The State of Oregon prohibits the installation of thermostats that contain mercury in commercial and residential buildings. "In accordance with ORS 455.355, the disposal of thermostats that contain mercury shall be in accordance with programs established by thermostat manufacturers, their representative or distributor, or by delivery to sites that will ensure that the mercury does not become part of the solid waste stream or wastewater." (b0 c-/ 4 Approved Plans: 1 set of approved plans, bearing the City of Tigard approval stamp, shall be maintained on the jobsite. The plans shall be available to the Building Division inspectors throughout all phases of construction. 106.4.2 OSSC When submitting revised drawings or additional information, please attach a copy of the enclosed City of Tigard, Letter of Transmittal. The letter of transmittal assists the City of Tigard in tracking and processing the documents. Respectfull a1 He . - Senior Plans Examiner