Permit =`' a CITY Y OF TIA BUILDING PERMIT PERMIT #: BUP2007 -00459 ili ° COMMUNITY DEVELOPMENT DATE ISSUED: 9/19/2007 : 13125 SW Hall Blvd., Tigard, OR 97223 503.639.4171 PARCEL: 2 S 115AA - 00100 SITE ADDRESS: 16194 SW 108TH AVE ' ZONING: R -25 SUBDIVISION: DURHAM PARK APARTMENTS LOT: 036 JURISDICTION: TIG PROJECT: BRIGHTWATERS AT READHAWK Project Description: Replace fire alarm control panel and devices. REISSUE: FLOOR AREAS EXTERIOR WALL CONSTRUCTION CLASS OF WORK: FPS FIRST: sf N: S: E: W: TYPE OF USE: COM SECOND: sf PROJECT OPENINGS? TYPE OF CONST: sf N: S: E: W: OCCUPANCY GRP: R1 TOTAL AREA: 0 sf ROOF CONST: FIRE RET? OCCUPANCY LOAD: BASEMENT: sf AREA SEP. RATED: STOR: HT: ft GARAGE: sf OCCU SEP. RATED: BSMT ?: MEZZ ?: REQD SETBACKS REQUIRED FLOOR LOAD: psf LEFT: ft RGHT: ft FIR SPKL: SMOK DET: DWELLING UNITS: FRNT: ft REAR: ft FIR ALRM : Y HNDICP ACC: BEDRMS: BATHS: IMP SURFACE: PRO CORR: PARKING: VALUE: $ 3,909.00 Owner: Contractor: DURHAM PARK LTD PTNRSHP SIMPLEXGRINNELL LP 1525 SW PARK AVE SUITE 200 6305 SW ROSEWOOD ST PORTLAND, OR 97205 LAKE OSWEGO, OR 97035 Contact #: PRI 503 - 683 -9000 Phone: FAX 503 - 675 -6521 Reg #: LIC 149921 FEES Description Date Amount REQUIRED ITEMS AND REPORTS [BUILD] Permit Fee 8/30/2007 $76.80 [TAX] 8% State Surcha 8/30/2007 $6.14 [FLS] FLS Pin Rv 8/30/2007 $30.72 Total $113.66 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more than 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952 - 001 -0010 through OAR 952 - 001 -0100. You may obtain a copy of these rules or direct questions to OUNC by calling 1 .246.6699 or 1.800.332.2344. Issued =41/1kil ��tLl _ i . v, Permittee Signature: - 1 _ _ -- Call 503.639.4175 by 7:00 a.m. for an inspection that business day. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. j 6 ( 94- -SC.).3 ( cab PTV Fire Protection System Building Permit Application FOR OFFICE USE ONLY City Tigard Ti and Received Date /B C� S U 8 m a / Permit No.: ' 1 5 1 13125 SW Hall Blvd., Tigard, OR 97223 Plan Review Vi ar _ ` . Phone: 503.639.4171 Fax: 503.598.1960 Date /B ,/� 0 Other Permit: Inspection Line: 503.639.4175 Date Read / 0 See Page 2 for T I G A K D p Not i fied /Method: 1u v Su pp information Internet: www.tigard- or.gov PP Y7$/e' 7 eAlizaczA 4 VAila TYPE OF WORK REQUIRED DATA: I- AND 2 -F Y DWELLI G ❑ New construction ❑ Demolition Permit fees* are based on the value of the work performed. Indicate the value (rounded to the nearest dollar) of all (L Addition/alteration /replacement ❑ Other: equipment, materials, labor, overhead, and the profit for the CATEGORY OF CONSTRUCTION work indicated on this application. ❑ 1- and 2- family dwelling 111 Commercial /industrial Valuation: $ ❑ Accessory building ❑ Multi- family Number of bedrooms: El Master builder ❑ Other: Number of bathrooms: i lt 19Cf JOB SITE INFORMATION AND LOCATION Total number of floors: Job site address: , -kee .) toc34 �. New dwelling area: square feet City/State /ZIP: t) I O re__ c -3-2234 Garage /carport area: square feet Suite/bldl. /a,d, Project name:+4rwatees p � Covered porch area: square feet Cross str�eet/dire • Jo• site: Deck area: square feet L A► 0 t: . i 7 014/ Other structure area: square feet REQUIRED DATA: COMMERCIAL -USE CHECKLIST Subdivision: 1 Lot no.: Permit fees* are based on the value of the work performed. Indicate the value (rounded to the nearest dollar) of all Tax map /parcel no.: equipment, materials, labor, overhead, and the profit for the DESCRIPTION OF WORK work indicated on this application. A ' t 1 Valuation: $ 3 , 9�Q P� a► 0_12_ � - i F GXw� G,�..a -1 - 4.. `,� � `F _ Existing building area: square feet New building area: square feet ❑ PROPERTY OWNER I ❑TENANT Number of stories: Name: Type of construction: Address: Occupancy groups: City/State /ZIP: Existing: Phone: ( ) Fax: ( ) New: 1 APPLICANT ❑ CONTACT PERSON NOTICE Business name: 'nib >�IHC C l l All contractors and subcontractors are required to be Contact name: �' Ck�t1� licensed with the Oregon Construction Contractors Board under ORS 701 and may be required to be licensed in the Address: C..,,S SI.J jurisdiction in which work is being performed. If the City/State /ZIP: p Dine C O O R �� applicant is exempt from licensing, the following reasons Phone: (s'D3) 3— 000 l Fax: : (sot& 6�'� (' Z.( E -mail: CONTRACTOR BUILDING PERMIT FEES* (Please refer to Business name: i i'Px �'_ r �.e if o fee schedule) (.0& ) Permit fee: Address: S lust' c� (•r- State surcharge (8% of permit fee): City/State /ZIP: L Ck ) �� ,t FLS plan review (40% of permit fee): Phone: VS ) G �5�o F ax: () ‘TS-- GSzl (Due upon application.) CCB lic.: /q%)( 2 / Total permit fees: 41 / /3 , 66 gn 1 / Amount received: / / Authorized signature: f I T his permit application expires if a permit is not obtained Print name: 'C..h (ap 4. -(. f 1..,0 Date: 9 iv„,_ * within 180 days after it has been accepted as complete. Fee methodology set by Tri- County Building Industry Service Board. I: \Building \Permits \FPS- PennitApp.doc 03/23/06 440- 4613T(11 /02 /COM/WEB) City of Tigard, Oregon ® 13125 SW Hall Blvd. O Tigard, OR 97223 'x rxt `yra. • September 19, 2007 l sie kt •/" y P 'Q RE: FIRE ALARM SYSTEM Y : y a.�T�I G�A�R� Project Information • Egg Building Permit: BUP2007 -00459 Construction Type: NA Tenant Name: Brightwaters @ Redhawk Occupancy Type: R -2 Address: 16194 SW 108 Ave Hazard: NA The plan review was performed under the State of Oregon Structural Specialty Code (OSSC) 2007 edition the Oregon Fire Code 2007 edition and NFPA 72. The submitted plans are approved subject to the following. Scope of Work: Replace old alarm panel, like for like, and check system. See scope of work and letter attached to cut sheets. General Requirements A separate low- voltage electrical permit is required for installation and inspection of alarm wiring. A completed inspection and testing form is required at the time of final inspection containing the information as outlined in NFPA section 10.6.2.3. TESTING — NFPA 72 Chapter 10, OFC 901.2.1, 901.5, 903.5 1. Upon completion of the installation, a satisfactory test of the entire system shall be made in the presence of the building inspector. All functions of the system or alteration shall be tested. 2. A record of completion in accordance with NFPD 72 verifying that the system has been installed in accordance with the approved plans and specifications shall be provided. 3. The permittee shall provide written certification to the Fire Chief that the system has been installed in accordance with the approved plans and specifications. A copy of the completed form shall be maintained on the premises and made available to the Fire Chief. VISUAL ALARMS — NFPA 72 - 5.14.5, 7.5.4, OSSC chapter 9 & 11 4. When required; Visual alarms shall be located not less than 80 inches and not more • than 96 inches above floor level. When a low ceiling exists, the visual alarm shall be Phone: 503.639.4171 0 Fax: 503.684.7297 ® www.tigard- or.gov o TTY Relay: 503.684.2772 • • mounted within the dimensions stated above and at least 6 inches below the ceiling. No place in a room shall be more than 50 feet from a visual signal. MANUAL ALARM - 1109.2.3.5, 1109.2.3.6 OSSC 5. Manual Fire Alarm activation devices when installed shall be mounted in the following reach ranges: • Forward Reach - 15 inches to 48 inches above the floor. • Side Reach — 9 inches to 54 inches above the floor. ALARM SIGNALS — OFC 903.4 6. Alarm, supervisory and trouble signals shall be distinctly different and shall be automatically transmitted to an approved central station, remote supervising station or proprietary supervising station as defined in NFPA 72 or, when approved by the fire code official, shall sound an audible signal at a constantly attended location. 7. Duct smoke detectors shall be connected to the building's fire alarm control panel when a fire alarm system is provided. Activation of a duct smoke detector shall initiate a visible and audible supervisory signal at a constantly attended location. Duct smoke detectors shall not be used as a substitute for required open -area detection. Approved Plans: 1 set of approved plans, bearing the City of Tigard approval stamp, shall be maintained on the jobsite. The plans shall be available to the Building Division inspectors throughout all phases of construction. 106.3.1 OSSC Premises Identification: Approved numbers or addresses shall be provided for all new buildings in such a position as to be plainly visible and legible from the street or road fronting the property. When submitting revised drawings or additional information, please attach a copy of the enclosed City of Tigard, Letter of Transmittal. The letter of transmittal assists the City of Tigard in tracking and processing the documents. Respectfully Dan Nelson, Senior Plans Examiner 'NCO Simplex Grinnell LP 6305 S.W. Rosewood Fire & Lake Oswego, Or. • Security 97035 Tele:503- 683 -9000 S®8stplexGr,nnell Fax:503- 675 -6521 www. simplexgrinnell. com City of Tigard Permit Department 13125 SW Hall Blvd. Tigard, OR 97223 Subject: Brightwaters at Redhawk 1Co19y ASSWSW 108 Ave. Tigard, OR 97224 Dear Plan Reviewer, Attached to this letter is the scope of work for this project, briefly explaining what SimplexGrinnell is trying to accomplish with the repair and replacement of the fire alarm system for Building 16194. I have spoken with Dan Nelson of the permit department and have informed him of the situation as well. Dan has asked that we attach the scope of work and cut sheets for the equipment to be installed, which is also attached to this letter. We do not have any plans to submit, this is going to be a replacement of the existing "non- working" fire alarm control panel, to be replaced by a new fire alarm control panel of the same manufacturer, reusing the peripheral devices if they are found to be in proper working condition. If in fact, the peripheral devices are not found to be working, they will be replaced with new devices. If you have any questions, please call our Lake Oswego branch and ask for Bryan Adams or myself. Thank you, ! OPP GITy OF TIGARD Approved ut � t Vi Brian Giannettino Conditionally Approved .............. ( 1 Project Manager See Latter to: Follow ........... ....... 1 1 Attached .......« l s , o r-AAA di.. '. rt' T . OFFICE COPY two SimplexGnnnell LP 6305 S.W. Rosewood Fire & Lake Oswego, Or. Security 97035 Tele:503- 683 -9000 Sin p®exGr®nipe®® Fax:503- 675 -6521 www. simplexgrinnell. com Scope of work: Brightwaters at Redhawk (Building 16194) This is to replace the fire alarm control panel and all the existing devices. (Device for device replacement only) This quote is assuming that all wiring is good, and up to code. This quote included time to troubleshoot why the existing end of line resisters are landed in FACP. If existing notification circuits are T- Tapped, a change order will need to be requited. If pull stations, bell, and piezo's are found to be in working order, owner will not be charged for parts not used. Pull a "System Down" FACP permit Price includes: - Troubleshoot for ground faults -Back boxes - Installation - Permits or fees - Device Terminations - Final system testing and checkout Price does not include: - CAD shop and riser drawings - Voltage drops & battery calculations -Wire, or cable - Conduit -Paint & patchwork - Covering existing cutout (FACP) -As Built Drawings • February 16, 2005 DF -52266 • A2 -260 e Fire.LITe 4 -Zone Fire Control Panel www.firelite.com Section: Conventional GE619ERAL rti California The Fire•Lite MS -4 and MS -4E Fire Alarm Control Panels 1 1p ' State Fire c: bring the latest in microprocessor technology to conventional s7 L ' ` Marshal fire controls. The MS -4 is compatible with the i 3TM smoke .� 297 -01 -E l :.•• 7165- 0075:200 detectors from System Sensor, and provide such advanced LISTED __. features as drift compensation, maintenance alert, and freeze warning. Automatic synchronization of audio /visual devices is S624 provided, using three selections for manufacturer protocol. The NAC protocol includes the ability to silence audible de- . . vices while strobes continue to flash, using only a single pair - . . of wires. - The MS -4 also is compatible with conventional input devices ,. such as two- and four -wire smoke detectors, pull stations, waterflow devices, tamper switches and other normally -open i ; contact devices. For 240 VAC operation, order MS -4E. See i 4 the Fire•Lite Device Compatibility Document 15384 for a com- 4 plete list of compatible devices. it t NOTE: Unless indicated otherwise, the term "MS -4" refers to .4 ilk *. • • both MS -4 and MS -4E models. �" FEATURES • Four Style B (Class B) IDCs (Initiating Device Circuits). • Two Style Y (Class B) NACs (Notification Appliance Circuits). • Optional module that converts all four IDCs and two NACs 0 . to Class A. - • 24 VDC. t • 13TM Technology features: MS -4 — Drift compensation automatically adjusts detector sen- — Selectable for System Sensor, Wheelock and Gentex sitivity and increases resistance to false alarms caused protocols. by dust accumulation. — Selective Silence feature allows manual silence of horns — Maintenance Alert LEDs (per zone) warn of excessive while strobes continue to flash on the same NAC. dirt accumulation, preventing false alarms (meets NFPA • Silent or Audible Walk Test operation mode commanded 72 requirements). from the front keypad, with automatic return to normal after — Detector sensitivity is automatically measured by the one hour of inactivity. detector, which automatically adjusts its sensitivity back • Programmable for combination tamper supervisory monitor to the factory settings when it becomes more sensitive and waterflow alarm on one zone. due to contaminants settling in the chamber. • — Wireless hand -held sensitivity meter eliminates the need Alarm verification selectable per zone. for voltmeters, magnets and a physical connection to • Each zone may be programmed for supervisory or fire, with the detector. The reader displays sensitivity in terms of separate red and yellow LEDs. percent per foot obscuration and provides text status • Disable switches provided per zone. indication. • NACs programmable for: — Supervisory LED (per zone) provides warning if a de- — Silence Inhibit tector senses temperature approaching freezing. — Auto Silence — Special test protocol and LED indication allows quick — Strobe Synchronization test of all detectors without need for a ladder. — Selective Silence (horn- strobe mute) • NAC synchronization features: — Temporal or Steady signal — Provides synchronization of standard ANSI audible sig- — Silenceable or Nonsilenceable nals as required by NFPA 72. • Form -C Alarm, Trouble and Supervisory relays. — Provides synchronization of ADA compliant strobes per • 3.0 A total usable current. NFPA 72. • 6.0 A total usable current available with optional second transformer. i 3TM is a trademark of System Sensor, a Honeywell company. • Optional dress panel (P /N DP- MS2/4). - Fire•Lite® Alarms is a Honeywell company. This document is not intended to be used for installation purposes. We try to keep R our product information up -to -date and accurate. We cannot cover all specific D gIh®l applications or anticipate all requirements. All specifications are subject to change w?ERYTr without notice. For more information, contact Fire•Lite Alarms, One Fire -Lite Place, Northford, MINIM 8 MANUFACIU�N6 A L I i Y SYSTEMS Connecticut 06472. Phone: (800) 627 -3473, Toll -Free FAX: (877) 699 -4105. DF-52266 • 02/16/05 — Page 1 of 2 • Control buttons: • Power- limited circuitry. - ACK (Acknowledge) • Normal operating voltage: nominal 24 VDC. - Alarm Silence • Maximum signaling current: 2.5 A total with standard trans- - Reset former. 5.0 A total (2.5 A maximum per NAC) with optional - Walk Test transformer. - Zone Enable /Disable (one per zone) • End -of -line resistor: 4.7K ohm, 1/2 watt (P /N 71252). • LED indicators: • Compatible devices: refer to Fire•Lite Device Compatibility - Fire Alarm (one per zone) Document 15384 for listed compatible devices. - Supervisory (one per zone) Form - Relays - Trouble (one per zone) • Trouble relay TB5 (fail- safe). - Maintenance (one per zone) • Alarm relay TB6. - AC Power • Supervisory relay TB7. - NAC Disable • Relay contact ratings: 2.0 A @ 30 VAC (resistive). - Zone Disable Auxiliary Outputs: - NAC Fault - Resettable Power - TB1 - System Trouble • Operating voltage: nominal 24 VDC. - Power Trouble • Maximum available current: 500 mA, appropriate for power- - Walk Test ing four -wire smoke detectors (see notes below). - Alarm Silence • Power - limited circuitry. - Earth Fault (on circuit board) - Battery Fault (on circuit board) - Nonresettable Power - TB1 - Charger Fault (on circuit board) • Operating voltage: nominal 24 VDC. • • Piezo sounder for alarm, trouble, supervisory and mainte Maximum available current: 500 mA (see notes below). nance. • Power - limited circuitry. • Optional plug-in 4XTMF transmitter module. NOTES: 1) See the Fire•Lite Device Compatibility Document 15384 • Optional plug 4XZMF zone relay module. for listed compatible devices. 2) Total current for nonresettable power, resettable power and two NACs must not exceed 6.0 A for • Optional 4XLMF transmitter module for RZA -4XF remote the MS - (requires optional second transformer). LED annunciator. OPERATION Door: Dimensions Door: 15.342" (38.97 cm) high x 14.677" (37.28 cm) wide x Activation of a compatible smoke detector or any normally- 0.375" (0.95 cm) deep. Backbox: 15.0" (38.10 cm) high x open fire alarm initiating device activates audible and visual 14.5' (36.83 cm) wide x 3.0" (7.62 cm) deep. signaling devices, illuminates an indicating LED, sounds the ���,�� ®X ®181�ITINlG piezo sounder at the FACP, activates the FACP alarm relay and operates an optional module used to notify a remote The cabinet can be surface mounted. The door is removable station or initiate an auxiliary control function. during installation by opening and lifting it off the hinges. The cabinet mounts using two key slots at the top of the backbox SPECIFICATIONS and two additional 0.250" diameter holes at the bottom. AC Power - TB8 PRODUCT LINE INFORMATION • MS -4: 120 VAC, 50/60 Hz, 2.3 A. MS -4 Four -zone conventional FACP; 120 VAC, 50/60 • MS -4E: 240 VAC, 50 Hz, 1.15 A. Hz, 2.3 A. • Wire size: minimum 14 AWG (2.0 mm with 600 V insula- MS-4E Same as above, but 240 VAC, 50 Hz, 1.15 A tion. operation. Battery (sealed lead - acid only) - J8 CAC-4 Class A converter module. Used to convert Style • Maximum charging circuit: normal flat charge 27.6 VDC @ B (Class 8) IDC to Style D (Class A) and Style Y 0.8 A. (Class B) NAC to Style Z (Class A). The module • Maximum battery charger capacity: 18 AH battery (two 7 connects to J1 on the MS -4 circuit board. AH batteries can be housed in the FACP cabinet. Larger batteries require a separate battery box such as the Fire•Lite 4XTMF Transmitter module. BB -17F). 4XLMF LED interface module. Initiating Device Circuits - TB3 XRM -24 Transformer assembly increases power from 3.0 • Alarm zones 1 - 4. A to 6.0 A. • Power - limited circuitry. RZA -4XF Remote annunciator - mounts in a single -gang • Operation: all zones Style B (Class B). box. • Normal operating voltage: nominal 22 VDC. 4XZMF Zone relay module. • Alarm current: 15 mA minimum. • Short-circuit current: 40 mA maximum. BB-17F Battery box, required to house two batteries greater than 7 AH to a maximum of 18 AH. • Maximum loop resistance: 100 ohms. • End -of -line resistor: 4.7K ohm, 1/2 watt (P /N 71252). 411/411UD Three input (channel) 411 and four input • Standby current: 4 mA. (channel) 411 UD dual -line Digital Alarm Communicator/Transmitters, which can be used • Refer to Fire•Lite Device Compatibility Document 15384 for as slave communicators with the MS -4(E) FACP. listed compatible devices. DP -MS2/4 Dress panel. Notification Appliance Circuits - TB2 • Two NACs on MS 4. MS -4RB Replacement board. Page 2 of 2 - DF -52266 • 02/16/05 • • E= -SILLS [i) *TEE"( PBA -AC & PBD -DC ® The Symbol of Protection UL Listed t �i0., 4 4 x • Sizes Available: 6" (150mm), 8" (200mm) and 10" (250mm) � 4 .-5 " :V Voltages Available: 24VAC f y ,u6°F''A,!'i t ,; 4 .i . b R .7 :i7 �. , , t I lug , '0',1%t; '', Y ,� , ° 12VDC (10.2 to 15.6) Polarized �5 I i.�, , > ° y.�- . 24VDC (20.4 to 31.2) Polarized `HI g �' ,, i m i y k lGS•"� <, :'1..,71:47-4-7-44q 4 R Re k ; { ' Y ` ' �� `" Service Use: Fire Alarm 4 �, ``` ; ' ' General Signaling � rte; , "'�° W ¢�' p ., BurglarAlarm "S44 o f " Environment: Indoor or outdoor use (See Note 1) `° ', ` b��, . , . 1% � . ,� -40° to 150 °F (-40° to 66 °C) ' 4 ,q ' . W Y (Outdoor use requires weatherproof ' "sgx -u� backbox.) a_ . Termination: 4 No. 18 AWG stranded wires 6" BELL SHOWN Finish: Red powder coating Optional: Model BBK -1 weatherproof backbox These vibrating type bells are designed for use as fire, burglar or general signaling devices. They have low power con- sumption and high decibel ratings. The unit mounts on a standard 4" (101mm) square electrical box for indoor use or on a model BBK -1 weatherproof backbox for outdoor applications. Weatherproof backbox model BBK -1, Stock No. 1500001. ALL DC BELLS ARE POLARIZED AND HAVE BUILT -IN TRANSIENT PROTECTION: SIZE CURRENT TYPICAL dB MINIMUM dB INCHES VOLTAGE MODEL NO. STOCK NO. (MAX) AT 10 FT. AT 10 FT. (mm) (3m) (2) (3m) (1) 6(150) 12VDC PBD126 1706012 .12A 85 76 8 (200) 12VDC PBD128 1708012 .12A 90 77 10 (250) 12VDC PBD1210 1710012 .12A 92 78 6 (150) 24V0C PB0246 1706024 .06A 87 77 8 (200) 24VDC PBD248 1708024 .06A 91 79 10 (250) 24VDC P802410 1710024 .06A 94 80 6 (150) 24VAC PBA246 1806024 .17A 91 78 8(200) 24VAC PBA248 1808024 .17A 94 77 10 (250) 24VAC PBA2410 1810024 .17A 94 78 6(150) 120VAC PBAl206 1806120 .05A 92 83 8 (200) 120VAC PBAl208 1808120 .05A 99 84 10(250) 120VAC PBAl2010 1810120 .05A 99 86 Notes: 1. Minimum dB ratings are calculated from integrated sound pressure measurements made at Underwriters Laboratories as specified in UL Standard 464. UL temperature range is -30° to 150 °F ( -34° to 66 °C). 2. Typical dB ratings are calculated from measurements made with a conventional sound level meter and are indicative of output levels in an actual installation. Potter Electric Signal Company • 2081 Craig Road, St. Louis, MO, 63146 -4161 • Phone: 800 - 325 - 3936 /Canada 888- 882 -1833 • www.pottersignal.com PRINTED IN USA MKT. #8850001 - REV S PAGE 1 OF 2 MFG. #5400776 - 5/05 • P BELLS PBA -AC & PBD -DC The Symbol of Protection DIMENSIONS INCHES (mm) FIG. 1 BELLS FIG. 2 WEATHERPROOF BACKBOX BOX HAS ONE THREADED 112" CONDUIT ENTRANCE 1 4 o 0 (250) f 121_ 5 3/4' _ 3 3/8' S' 4 8" I (146) O (86) (127) (200) 6" OT j 3 3/8" - 1 5/81-.1-- (86) (41) 2 11/16" f 4 i (68) DWG. #776 - 1 ( ) DWG. #776 -2 FIG. 3 WIRING (REAR VIEW) D.C. BELLS (OBSERVE POLARITY) A.C. BELLS RED (IN) A diMm ii.. RED (OUT) WHITE (8) WHITE (OUT) FRON CONTROL PANEL r411111TO NEXT BELL FROM CONTROL PANEL OR OR END -OF -UNE OR PRECEDING BELL I� RESISTOR PRECEDING BELL r �I� BLACK (IN) _� BLACK (OUT) BLACK (IN) .‘11111111111V BLACK (OUT) CAUTION: CAUTION - WHEN ELECTRICAL SUPERVISION IS REQUIRED USE IN AND 001 LEADS AS SHOWN. WHEN ELECTRICAL SUPERNSION IS REQUIRED USE 1N AND OUT LEADS AS SHOWN. NOTES: NOTES: 1. OBSERVE POLARITY TO RING D.C. BELLS. 1. WHEN USING A.C. BELLS, TERMINATE EACH EXTRA WIRE SEPARATELY 2. RED WIRES POSITIVE ( +) AFTER LAST BELL. 3. BLACK WIRES NEGATIVE ( -) 2. END -OF -UNE RESISTOR IS NOT REOUIRED ON A.C. BELLS. DWG. #776 -3 INSTALLATION 1. The bell shall be installed in accordance with NFPA 72 or local Ahj. The top of the device shall be no less than 90" Aff and not less than 6" below the ceiling. 2. Removethegong. 3. Connect wiring (see Fig. 3). 4. Mount bell mechanism to backbox (bell mechanism must be mounted with the striker pointing down). 5. Reinstall the gong (be sure that the gong positioning pin, in the mechanism housing, is in the hole in the gong). 6. Test all bells for proper operation and observe that they can be heard where required (bells must be heard in all areas as designated by the authority having jurisdiction). PRINTED IN USA MKT. #8850001 - REV S PAGE 2 OF 2 MFG. #5400776 - 5/05 SF :j ., .:?" h tr N y f . r , GENTE .., . .. , ,, tl • " d SI 12 or 24 V ®C, Low Current Mini -horn SERIES Temporal (GX93) or Continuous (GX91) tone, with Terminal Blocks , Applications ! ; a , , The GX91/GX93 Series mini -horn is a select either the continuous tone or the 1. ';' , � � ' . I ' , ` high quality remote signaling appliance that temporal 3 evacuation tone. g, , a I; i i offers dependable remote annunciation. The GX93 can be used on the same sync `• The GX91 /GX93 is listed for use with circuit (AVS44) as other Gentex signals, both filtered and unfiltered power. such as the Commander series. _ e q The GX91 is a continuous tone mini horn. The GX91/GX93 appliances are UL 464 d Pd t 4 This unit is not synchable with the AVS44 listed for use with fire protective systems ` : ,, x' f r r control module. It is however synchable and are warranted for three years from the w.4M ......_ from the panel. date of purchase. With the GX93 a jumper is provided to GX91/GX93 Remote Audible Signal Standard Features • Single Unit is capable of 12 or 24 • Variety of Mounting Options for New Approvals VDC determined by the input Construction and Retrofit Applications voltage • To Synchronize the GX93 use the �� �,, _ • Selectable Temporal 3 or Continuous Gentex AVS44 Control Module F' = Tone on the GX93 (Jumper Pin) • UL 464 Listed for Fire Protective m U� ` i . mil= �„�,,, • GX91 has a Continuous Tone horn Service il U.A. only • Textured Finish High Impact Plastic • BFP (City of Chicago) • Horn Frequency is 3100Hz Faceplate, Available in Fire Alarm • BS +AIMEA #285 91 - - XVI • Terminal Blocks (12 AWG to 18 AWG) Red or Off -White • CSFM Listing 7135 0569:126 • Low Current Consumption • UL ULC Dual listed 464 Available Models Horn In Anechoic In UL Reverberant Model Part Input Current Room dBA Room Per Number Number Voltage Range (mean DC) @10Ft. UL 464 @ 24 VDC GX91 R 904 -1274 8 -33 v 4 -17mA 90 85 dBA GX91W 904 -1275 8 -33 v 4 -17mA 90 85 dBA GX93R 904 -1276 8 -33 v 5 -25mA 90 81* dBA GX93W 904 -1277 8 -33 v 5 -25mA 90 81* dBA Input Voltage Range: 8 -33 VDC OR VFWR Operating temperature Indoor: 32° to 120 °F 0° to 49 °C GX91 Average Horn Current is 1 5mA @24VDC GX93 Average Horn Current is 22mA @24VDC * The sound output for the Temporal 3 tone is rated lower since the time the horn is off is averaged into the sound output rating. While the horn is producing a tone in the . Temporal 3 mode its sound pressure is the same as the continuous mode. "R" = Red faceplate "W' = Off -White faceplate a Y' i. � ry > r rt >, GE ; 'T, , , • u ' , r � ,..,,, ...,- ' - - - - - — - - I1x' ' / 4 ty ? ¢ ° x.1 7 } '%': ,I.,, Y t -- ., •M: Dimensions SERIES Mounting C I , Immor I Mb 470 (K) 111) ' ..''' 1 1'17k...iv 1 11110 oU 0 i _ I. AI r RJR x,11 I !i v im` LISIED CDNTRCL 11)311- 0 PAMEL SUMMED ��■ E11110F11NE RESISTOR SOK 4:01C1➢r RED 6 �- / RED RED' Pa v 11 E RACK ® � a .' euoat Wiring Diagram �� ,,,r _, , "I 1 >r�Y00la0RrM PO0.0LNLOIA000OADITU HAESEIL 101011OOPM L00111L0 SGP -R SGP -W "'` +��� — FA Trim Plate for GX91 /GX93 a A rchict & Eng ineering Specifications The alarm hor shall be Gentex Model il id IS : , ,...id FA . 11 �j " G X91 /GX93. te The appli ance listed with U nderwriters Laboratories for shall use be with Fire Protective Signali tm peak sound output of Sys 9 s or and greater produce as a 24 units per carton measured in an anechoic chamber. 6 pounds per carton appliance shall be of solid -state construction The and be polarized to operate from 8 -33 VDC with a 15 milliamp current drain on the GX91 and a • e I . 22 milliamp current drain on the GX93 at 24 , '- - VDC. The appliance shall be provided with 2 O P Acr 1 l "` . -" terminals, and mount to a variety of single -gang Fire Protection Products: www.gentex. back boxes. 10985 Chicago Dr., Zeeland, MI 49464 616/392 -7195 1- 800/436 -8391 FAX: 616/392 -4219 0 Printed on Recycled Paper Gentex corporation reserves the right to make changes to the product data sheets at their discretion. GXO301 01-3 13 a Simplex Multi- Application Peripherals UL, ULC, CSFM Listed; FM Approved; Non - Coded, Non - Addressable Manual Stations; MEA (NYC) Acceptance* 2099 Series Single and Double Action Operation Features Manual fire alarm stations for general purpose applications: • Operation complies with ADA requirements i= (_i_'OW • Pull lever protrudes when alarmed • Break -rod is supplied (use is optional) • Screw terminals for wiring connections • Tamper resistant reset key lock (keyed same as • Simplex fire alarm cabinets) Single Action Station Operation types include: • Single action J T �' 1 1 1 ® • Double Action, Breakglass or Push Type • Institutional Model, key operated only EtR PUSH • Optional Local Alarm cover —— — • Optional pre - signal and annunciator contacts el i . Multiple mounting options: .--- - -. -- ! : .w . • Surface or semi -flush with standard boxes or matching (= - ) [ • ='' ) Simplex boxes • • Flush mount adapter kit Double Action Double Action Station (Breakglass) Station (Push Type) UL listed to Standard 38 , Operation 1, . Activation of the Simplex single action manual stations 1 l requires a firm downward pull to activate the alarm I 1 switch. Completing the action breaks an internal plastic * ! ` 1 DaSN break -rod (visible below the pull lever, use is optional). I • OPERATED • 1 The use of a break rod can be a deterrent to vandalism ONLY without interfering with the minimum pull requirements I I • needed for easy activation. The pull lever latches into the alarm position and remains extended out of the housing to provide a visible indication. Single Action Station with Local Fire Alarm Double Action Stations (Breakglass) require the Institutional Cover Cover Option operator to strike the front mounted hammer to break the glass and expose the recessed pull lever. The pull lever then operates as a single action station. Operation (Continued) Double Action Stations (Push Type) require that a Pre - Signal Option activates when the lever is pulled. spring loaded interference plate (marked PUSH) be General alarm initiation requires a key to activate a pushed back to access the pull lever of the single action keyswitch located behind the pull lever. station. Station Reset requires the use of a key to reset the Station reset requires the use of a key to reset the manual station lever and deactivate the alarm switch. manual station lever and deactivate the alarm switch. (If If the break -rod is used, it must be replaced. the break -rod is used, it must be replaced.) Testing requires physical activation of the pull lever Station testing is performed by physical activation of (except for institutional stations). the pull lever. Electrical testing can be also performed by unlocking the station housing to activate the alarm switch. ' Refer to page 2 for models with MEA acceptance. These products have been approved Institutional Stations activate by key operation only by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California allowing access for manual alarms to be initiated by Health and Safety Code. See CSFM Listing 7150-0026:175 for allowable values andlor 8 y conditions conceming material presented in this document. It is subject to re- examination, authorized personnel. Operation requires key insertion revision, and possible cancellation. Additional listings may be applicable; contact your and opening of the station cover. local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Safety Products Westminster. S2099- 0007 -15 7/2007 • Application Reference Refer to NFPA 72, the National Fire Alarm Code, and all 3. At least one station shall be provided on each floor. applicable local codes for complete requirements for Additional stations shall be provided to obtain a manual stations. The following summarizes the basic travel distance not more than 200 ft (61 m) to the requirements. nearest station from any point in the building. 1. Stations shall be located in the normal path of exit 4. When manual station coverage appears limited in any and distributed in the protected area such that they way, additional stations should be installed. are unobstructed and readily accessible. 2. Mounting shall be with the operable part not less than 3 -1/2 ft (1.1 m) and not more than 4 -1/2 ft (1.37 m) above floor level. Product Selection Single Action Models (General Alarm) Model MEA Pre - Signal Annunciator Annunciator Local Alarm Institutional Mounting Contacts, N.O. Contacts, N.C. Cover Cover Notes 2099 -9754 ✓ 1 2099 -9101 ✓ ✓ 2099 -9102 J ✓ 2 2099 -9107 ✓ ✓ 2099 -9755 ✓ ✓ 1 2099 -9762 ✓ ✓ 1 Double Action Models (General Alarm) Model MEA Break -Glass Push Pre - Signal Annunciator Annunciator Mounting Contacts N.O. Contacts N.C. Notes 2099 -9103 ✓ ✓ 1 2099 -9104 ✓ ✓ ✓ 2099 -9105 ✓ ✓ ✓ 2 2099 -9108 ✓ ✓ ✓ 2099 -9756 ✓ J 1 2099 -9757 ✓ ✓ ✓ 2099 -9758 ✓ ✓ ✓ 2 2099 -9759 ✓ ✓ ✓ Accessories Model Description 2099 -9803 Replacement breakglass (standard, English) 2099 -9804 Replacement break -rod 2099 -9819 Flush adapter kit, black (refer to page 4) 2099 -9820 Flush adapter kit, beige (refer to page 4) 2099 -9822 Replacement retaining clip for breakglass 2099 -9828 Institutional cover kit 2975 -9178 Red, surface mount box, sheet metal, 5- 3/16" H x 4" W x 2- 3/16" D (127 mm x 102 mm x 56 mm) 2975 -9022 Red, cast aluminum surface mount box, 5" H x 3 -7/8" W x 2- 3/16" D (127 mm x 98 mm x 56 mm) Notes: 1. These models can be semi -flush mounted using a standard single gang 2 -1/2" (64 mm) deep switch box. DO NOT RECESS BOX, mount box flush or with 1/16" (2 mm) maximum protrusion. These models can also be surface mounted on a Wiremold box model number V5744S, 4 -5/8" H x 2 -7/8" W x 2 -1/4" D (117 mm x 73 mm x 57 mm). 2. For surface mount, these models require 2975 -9178 or 2099 -9022 boxes. For semi -flush mount, these models require a 4" (102 mm) square box with a single gang cover plate (see diagram on page 3). Additional Manual Station Reference Non - Addressable Manual Stations Data Sheet Addressable Manual Stations Data Sheet Releasing Stations S2099 -0010 Standard Addressable S4099 -0001 Stations for hazardous locations (Ring -Pull) S2099 -0008 Addressable for Releasing S4099 -0002 Metal housing and explosion - proof /weather -proof stations (T- Handle) S2099 -0009 Wire Guard (addr. /non - addr.) S2099 -0004 2 S2099- 0007 -15 7/2007 Surface;Mountin "• Reference: 2975 -9178 Box 2975-9022 Cast Box 5 -3/16" H x 4" W x 2- 3/16" D Knockouts located 5" H x 3 -7/8" W x 2 -3/16" D (132 mm x 102 mm x 56 mm) top and bottom (127 mm x 98 mm x 56 mm) (ordered separately) (ordered separately) fir' NIIMITI Simplex 2975 -9178 box (shown for reference) i 0 Side View FIRE ED ALARM Station cover hinges open for 1 I . 0 installation access 111 PULL DOWN 1 Access " 5" conduit located for 3/4 top threaded bottom and (127 mm) 13 Simplex 1" (25.4 mm) l e--- 3 -3/4" (95 mm)-1)1 Semi FI Mountin. Reference;' Single Gang Box Mount 4" Square Box Mount Single gang box, 2 -1/2" deep 4" (102 mm) square box, 2 -1/8" (54 mm) minimum (64 mm), RACO #500 or equal depth, RACO #231 or equal (supplied by others) (supplied by others) 71 if Mount flush or with It / 1/16 "(2 mm) C maximum extension 4" Square box DO NOT RECESS with cover plate Station tsi■ FIRE ® ALARM side view Single gang cover plate, 3/4" 1111 • (19 mm) extension, RACO #773 PULL DOWN or equal (supplied by others) Single gang �■ box outline Wall surface Semi -Flush Mount Side View O Simplex 3 S2099- 0007 -15 7/2007 Flush Mount References Flush mount adapter kit 2099 -9819, Black 7 2099 -9820, Beige * r ? , Box must be recessed into wall ' � 1 1" to 1 -1/8" (25.4 mm to 29 mm) r . r & Fl e 3 _ , ,:i„.:,,5„.„.„„ 4 4 1 ,, :.,, , , ,. c) .„ .; ,..:: ,..,, o , , , ,,s , t::-, , ,,- : ;',..;,,,)„, ,, ,h,:::: r4t : , - , , ,, , ,,,, ,,p2 ,- ! -- - ,t s:,,,,lit,, .„,,- .-,',,,, 0 8 ' a cutout must be a , (203 mm) Hol Ty o v ^ e 2 I PULL DC \ N m inimum of 6" H by 5" W kr' . 0 6 '� ®,� � t, 152 mm by 127 mm) O ( (152 q .. .x x'11 0 z % 0�1 <8 r S � I i r .� s v s Yt o4` .,..0n,:m:i ,,,,,i„,„:.::,„...„, ,...0.,„,„,,,,,,,,,,,,,,v, ,.. �. *\-- 4-11/16"(119 mm) square box, 2 -1/8" ', ,, of r (54 mm) minimum r , " �. ,a m Wall depth (by others) 4 -3/4 "(121 mm) — surface . 6 -3/4 "(171 min) Front View Side View S •;eciflatit?ns Wire Connections Screw terminal for in /out wiring, for 18 to 14 AWG wire UL Listed Temperature Range 32° to 120° F (0° to 49° C) intended for indoor operation Humidity Range Up to 93% RH at 100° F (38° F) Housing Color Red with white raised lettering Material Housing and pull lever are Lexan polycarbonate or equal Pull Lever Color White with red raised lettering Housing Dimensions 5" H x 3 -3/4" W x 1" D (127 mm x 95 mm x 25 mm) Tyco. Simplex, and the Simplex logo are trademarks of Tyco International Services AG or its affiliates in the U.S. and /or other countries. NFPA 72 and National Fire Alarm Code - are registered trademarks of the National Fire Protection Association (NFPA). Lexan is a trademark of the General Electric Co. Wiremold is a trademark of the Wiremold Company Simplex Tyco Safety Products Westminster • Westminster, MA • 01441 -0001 • USA S2099- 0007 -15 7/2007 ® www.tycosafetyproducts-usa-wm.com © 2007 Tyco Safety Products Westminster. All rights reserved. All specifications and other information shown were current as ofdocument revision date and are subject to change without notice. ® Simplex Fire Alarm Control Panel Accessories Listings* System Batteries, Sealed Lead -Acid; with Applications Reference for Battery Cabinets, and Battery Cabinets with Charger Features Rechargeable, sealed lead -acid batteries: • Lead - calcium grid structure with immobilized electrolyte in absorbent separator • Low maintenance with no need to add water • Low self - discharge characteristics • One - piece, high impact polystyrene cell cover with high reliability dual seal construction • UL 924 recognized pressure relief valves Available in a variety of capacities: • Batteries for internal mounting range from 6.2 Ah up to 50 Ah, depending on control panel cabinet size • Larger batteries, up to 110 Ah, mount in external battery cabinets that are available with internal chargers • Includes battery chargers with communications compatibility for use with 4010 Series fire alarm control panels and with 4100U Series fire alarm control panels Descri •tion Simplex rechargeable sealed -lead acid batteries provide Compatible Sealed Lead Acid Batteries can be Installed Inside Fire Alarm Control Panel Cabinets reliable and repeatable discharge and recharge characteristics for use in fire alarm and other systems / applications. They are designed with immobilized / electrolyte in an absorbent separator, allowing them to provide rated capacity on the first cycle. Because of their sealed construction, packaging is allowed within the system electronics enclosure (see illustration on page 2). When this is applicable, the quantity of 7 1tb system cabinets and the battery wiring distances are both l . . minimized. Where required, external battery cabinets can be close - nippled to the control panel to house larger Remote Battery Cabinets are Available for batteries with battery chargers available in some battery Larger Battery Requirements cabinet sizes. Batter Details Battery Details (Continued) Disposal. Battery chemicals and materials can be Charging. These batteries are intended to be used with recycled. Refer to information shipped with the battery or compatible Simplex battery chargers. on its case. Return to the battery manufacturer or to a Series Connections. These batteries are required to be similarly qualified battery processing facility for proper connected in series to produce 24 V system voltage. disposal. Battery sets must be of identical voltage, model number, appearance, and approximately the same date of manufacture for proper operation. Refer to details on page 4 and to the referenced individual product data Testing. Battery capacity testing is recommended to be sheets for agency listing status of battery cabinets and chargers. The batteries • performed by using a sealed lead - acid battery tester detailed in this document meet the requirements of UL, ULC, and Factory designed to withdraw a minimum of battery charge. The Mutual for use with respective equipment battery chargers as listed on page 3. g ry g Contact your local Simplex product supplier for proper battery selection per preferred tester applies a variety of amplitude and system requirements. Listings and approvals under Simplex Time Recorder duration controlled test pulses that compares terminal Co. are the property of Tyco Safety Products Westminster. voltage against those predicted for the specific battery size. (Testing is available through your local Simplex product supplier.) S2081- 0006 -18 5/2007 • Bather Construction` Reference'`' Actual appearance will vary with battery size. Sealed outer cover Quick connect or post type terminal Vent hole (type varies with battery size) Potting material, black for negative, red for positive (polarity is also clearly ` J� marked with + and -) ���� Pressure relief valve Inner cover Absorbent separator used I to immobilize electrolyte I'/ Sem- ermeable Lead - calcium grids ( membrane separator Cell group o, Cell case (high impact polystyrene) Batter Si e S • eclflcations; Battery Model Capacity 20 Hour Width* Depth* He w Approx Discharge Rate Terminals Weight * 2081 -9272 6.2 Ah 6 -1/8" (156 mm) 2 -5/8" (67 mm) 4" (102 mm) 5.75 Ibs (2.6 kg) 2081 -9274 10 Ah 6" (153 mm) 4- 1/16" (103 mm) 4" (102 mm) 9.2 Ibs (4.2 kg) 2081 -9288 12.7 Ah 6" (153 mm) 4" (102 mm) 4" (102 mm) 9 lbs (4.1 kg) 2081 -9275 18 Ah 7 -1/4" (184 mm) 3 -3/8" (86 mm) 6 -5/8" (168 mm) 14.3 Ibs (6.5 kg) 2081 -9287 25 Ah 6 -5/8" (168 mm) 5" (127 mm) 7" (178 mm) 19.4 Ibs (8.8 kg) 2081 -9271 (rectangular case, 33 Ah 12 -1/2" (318 mm) 3 -3/8" (86 mm) 7 -1/16" (179 mm) 26.6 Ibs (12.1 kg) typically for service) 2081 -9276 ( "square" case, 33 Ah 7 -3/4" (197 mm) 5 -1/4" (133 mm) 6 -3/4" (171 mm) 26.5 Ibs (12 kg) use for new) 2081 -9296 50 Ah 9 -1/2" (241 mm) 5 -1/2" (140 mm) 8 -7/8" (225 mm) 41.8 lbs (19 kg) 2081 -9279 110 Ah 11- 3/16" (284 mm) 10 -1/2" (267 mm) 9" (230 mm) 82 Lbs (37 kg) * Dimensions and weight are per battery and are for reference only. Exact size may vary. Refer to the tables on page 3 mounting compatibility. These batteries are 12 V each and series connected for 24 V system use. NOTE: When wired in series for 24 V output, these batteries are to be of identical voltage, appearance, model number, and approximately the same date of manufacture. `General a ecificatlons: Nominal Voltage Rating 12 Volts per battery Discharge Rating 20 Hour Rate • Typical Charge /Discharge Cycles 100 to 150 Preferred Charge Temperature Range 60° F to 90° F (15.6 °C to 32.2° C) 2 S2081- 0006 -18 5/2007 aBattery ,Compatibility.;for,FiretAlarm Control Panel Mounting;; NOTE: Refer to individual fire alarm control panel product data sheets for additional battery application information Battery Simplex Control Panel Model Series (see legend and notes below) Model Capacity 4008 (all models) (2, 4 or 6-Unit) (2, 4 or 6-Unit) 4006 & 4009 4100 & 4120 4020 4003 4004 4004R 4005 4010 4100U 2081 -9272 6.2 Ah ✓ ✓ ✓ ✓ ✓ ✓ ✓ 1, 2, or 3 bay ✓ ✓ 2081 -9274 10 Ah ✓ ✓ ✓ ✓ ✓ ✓ ✓ 1, 2, or 3 bay ✓ ✓ 2081 -9288 12.7 Ah ✓ NA ✓ ✓ ✓ ✓ ✓ 1, 2, or 3 bay ✓ ✓ 2081 -9275 18 Ah ✓ NA Note 3 ✓ Ext Ext Note 2 1, 2, or 3 bay ✓ ✓ 2081 -9287 25 Ah NA NA Note 3 Ext Ext NA ✓ 1, 2, or 3 bay ✓ Ext 2081 -9271 33 Ah NA NA Note 3 Ext NA NA Note 3 1, 2, or 3 bay Ext Note 4 (rectangular) 2081 -9276 33 Ah NA NA Note 3 Ext NA NA Note 3 1, 2, or 3 bay ✓ Ext ( "square ") 2081 -9296 50 Ah NA NA Note 3 NA NA NA Note 3 2 or 3 bay Ext Ext 2081 -9279 110 Ah Requires external battery cabinet ✓ = Can be placed in the respective equipment cabinet Ext = External battery cabinet is required, refer to selection chart on page 4 NA = Not applicable /not compatible NOTES: 1. These batteries meet the requirements of UL, ULC, and Factory Mutual for use with respective equipment battery chargers listed above. Contact your local Simplex product supplier for proper battery selection per system requirements. 2. 4010 Cabinets will accommodate 2081 -9275, 18 Ah batteries, but will not allow bottom entry conduit. 3. Use 4081 series companion cabinet and charger, refer to page 4. 4. 4020 Cabinets will accommodate 2081 -9271, 33 Ah batteries, but will not allow bottom entry conduit. 5. Some control panel models are listed for battery replacement reference only. i. E3CIE■iiiA(434tfeiVICifirt"1" 1 6 - ( - COrifriti bility.Reference ^ , Battery Cabinets without Chargers (connects to charger in panel) 2081 -9275 2081 -9287 2081 -9271 2081 -9276 2081 -9296 2081 -9279 Cabinet Panel Compatibility 18 Ah* 25 Ah Rectangular 33 Ah Square 33 All 50 Ah 110 Ah 2081 -9270 multiple ✓ ✓ ✓ ✓ ✓ NA 2081 -9280 4100U/4100+ NA NA NA NA NA ✓ 20819281 multiple ✓ ✓ ✓ ✓ ✓ NA 2081 -9282 4009 -9801 multiple ✓ ✓ *• NA NA NA NA 4009 -9802 multiple ✓ NA ✓ NA NA NA Battery Cabinets with Chargers 2081 -9275 2081-9287 2081 -9271 2081 -9276 2081 -9296 2081 -9279 Cabinet Panel Compatibility 18 Ah* 25 Ah Rectangular 33 Ah Square 33 All 50 Ah 110 Ah 4081 -9301 4081-9302 4004R and 4010 ✓ ✓ ✓ ✓ ✓ NA 4081 -9303 4081 -9304 4081 -9306 4100U NA NA NA r NA ✓ ✓ 4081 -9308 * Batteries smaller than those listed are normally mounted in the product cabinet ** 25 Ah capacity was effective as of 7/2005. ✓= Can be placed in the respective equipment cabinet NA = Not applicable /not compatible 3 S2081- 0006 -18 5/2007 Exfernal Specification Reference:;; Battery Cabinets Without Chargers; Shallow Design with Front Door Model Color Listings Description Dimensions 2081 -9281 Beige UL and 2 -Unit, 4100 style cabinet without charger; with locking 25 -3/4" W x 20-3/4" H x 6-3/4" D FM solid door and battery shelf, primarily for use with 50 Ah (654 mm x 527 mm x 171 mm) 2081 -9282 Red batteries 4009-9801* Beige UL and For up to 25 Ah External battery cabinet without charger, 16 -1/4" W x 13 -1/2" H x 5 -3/4" D FM batteries* with locking solid door and battery (413 mm x 343 mm x 146 mm)* For up to 33 Ah harness; for close - nippled mounting to 25 -3/4" W x 20 -3/4" H x 4 -1/8" D 4009 -9802 Beige UL batteries fire alarm control panel cabinet (654 mm x 527 mm x 105 mm) * Depth increased for 25 Ah batteries effective 7/2005. Battery Cabinet Without Charger; Deep Design with Hinged Lid Model Color Listings Description Dimensions 2081-9270 Red Not listed Battery cabinet without charger; cabinet has vented front, 26 -1/2" W x 12" H x 12" D and hinged lid with support rod and lock on top (673 mm x 305 mm x 305 mm) Chargers for use with 4010 Fire Alarm Control Panels and 4004R Suppression Release Systems (refer to data sheet S4081 -0001) Model Color_, Input Voltage Description Dimensions 4081 -9301 Beige Battery cabinet with charger for the 4010 and 120 VAC 4004R fire alarm control panel; for u to 50 Ah 4081 -9302 Red 22 -1/2" W x16 -3/4" H x 8 -3/8" D batteries; with front door 4081 -9303 Beige Listings include: UL, ULC, FM, CSFM, and MEA (572 mm x 425 mm x 213 mm) 220/240 VAC g 4081 -9304 Red (NYC), see data sheet for details Battery Cabinet Without Charger for 110 Ah Batteries; for use with compatible panel mounted chargers (refer to data sheet S2081 -0012) Model & Compatible Color Cabinet Description • Charger Description Dimensions Listings Chargers 4100 -9xxx 4100U System Power Supplies Series (SPS) 4100 -5111 Battery cabinet for 4100 -5112 4100U Additional SPS 2081 - 9279,110 Ah 4100 -5113 2081 -9280 batteries; includes 4100 -5125 4100U Remote Power Supply Listings Red 80 A battery fuse, 4100 -5126 (RPS) 26-1/2" W x 12" H x 12" D include: UL terminals and 4100 -5127 (673 mm x 305 mm x 305 mm) and CSFM battery connection 4100 -5120 cables; see data 4100 -5121 4100U TrueAlert Addressable sheet for details 4100 -5122 Power Supply (TPS) 4100 -0104 4100 -0114 4100 Legacy power supplies 4100 -0124 41000 Compatible Battery Cabinet With Charger for 110 Ah Batteries (for ULC listed systems and for other applications unable to use panel mounted power supply charger; refer to data sheet S4081 -0002) Model Color Input Voltage Description Dimensions 4081 -9306 Red 120 VAC Battery cabinet with charger for up to 110 Ah batteries; 220/230/240 VAC, NOTE: Required for ULC listed charging of 27 -7/8" W x 13 -1/2" H x 14 -5/8" D , 4081 -9308 Red 110 Ah batteries; Listings include: UL, ULC, FM, (708 mm x 343 mm x 371 mm) multi- tapped CSFM, and MEA (NYC), see data sheet for details 4100 -9837 Green LED Power -on Indicator Kit, required for ULC listing, mounts above access panel using knockout provided Tyco, Simplex, and the Simplex logo are trademarks of Tyco International Services AG or its affiliates in the U.S. and /or other countries. Simplex Tyco Safety Products Westminster • Westminster, MA • 01441 -0001 • USA S2081 0006 - 5/2007 ® www.tycosafetyproducts-usa-wm.com © 2007 Tyco Safety Products Westminster. All rights reserved. All specifications and other information shown it were current as of document revision date and are subject w change without nonce.