Loading...
Permit ' , BUILDING PERMIT 71 CITY .OF TIGARD COMMUNITY DEVELOPMENT DATE SSU 5/24/2007 6 00249 T GAR D, 13125 SW Hall Blvd., Tigard, OR 97223 503.639.4171 PARCEL: 1S136DA-00700 SITE ADDRESS: 11530 SW PACIFIC HWY ZONING: C - G SUBDIVISION: LOT: JURISDICTION: TIG PROJECT: HI HAT Project Description: Type 1 hood. REISSUE: FLOOR AREAS EXTERIOR WALL CONSTRUCTION CLASS OF WORK: FPS FIRST: sf N: S: E: W: TYPE OF USE: COM SECOND: sf PROJECT OPENINGS? TYPE OF CONST: 5N sf N: S: E: W: OCCUPANCY GRP: A3 TOTAL AREA: 0 sf ROOF CONST: FIRE RET? OCCUPANCY LOAD: BASEMENT: sf AREA SEP. RATED: STOR: HT: ft GARAGE: sf OCCU SEP. RATED: BSMT ?: MEZZ ?: REQD SETBACKS REQUIRED FLOOR LOAD: psf LEFT: ft RGHT: ft FIR SPKL: Y SMOK DET: DWELLING UNITS: FRNT: ft REAR: ft FIR ALRM : Y HNDICP ACC: BEDRMS: BATHS: IMP SURFACE: PRO CORR: PARKING: VALUE: $ 3,367.00 Owner: Contractor: HI HAT INC HUSER SALES + SERVICE INC 11530 SW BARBUR BLVD 231 TILLAMOOK PORTLAND, OR 97219 PORTLAND, OR 97227 Contact #: PRI 503 - 248 - 1948 Phone: FAX 503 - 248 - 7077 Reg #: LIC 116821 FEES Description Date Amount REQUIRED ITEMS AND REPORTS [BUILD] Permit Fee 5/3/2007 $81.70 [FLS] FLS Pln Rv 5/3/2007 $32.68 [TAX] 8% State Surcha 5/3/2007 $6.55 Total $120.93 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more than 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952 - 001 -0010 through OAR 952 - 001 -0100. You may obtain a copy of these rules or direct questions to OUNC by calling 503.246.6699 or 1.800.332.2344. / X7'5 Issued By: � � � • � 1 >/ � Permittee Signature; • Call 503.639.4175 by 7:00 a.m. for an inspection that business day. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. Fire Protection ystem FIT �iw `‹ NS - w ^T 0 - - T44.42 ,,,,, , — Building Permi � „ 6,� 1„ e I FOR OFFICE USE ONLY .. ti : ! ., . Received Building '/ ,, -f Date/By: /�� 40 Permit No .9 4 7 V DCC 1 Cit of Tigard Planning r val Other Y g MAY 3 2007 Date /By: Permit No.: 13125 SW Hall Blvd. Plan Revi /..., / Other Tigard, Oregon 97223 CITY GF T iGARD Date /By I O Permit No.: Phone: 503- 639 -4171 Fax: Bin ]" '� f . ist t ►!.«,r:dt t' l A Post- Revie,`N J Land Use �= ;� `, I I Date /By: Av \ J / 1 OT Case Internet: www.ci.tigard.or.us �� g Contact J ®See Page 2 for 24 -hour Inspection Request: 503- 639 -4175 Name /Method: Supplemental Information as-u8 1� \- 1,v..e =s c-k_o-e- �I € c-. - TYPE OF WORK REQUIRED DATA: ❑ New construction ❑ Demolition 1 & 2 FAMILY DWELLING Er Addition/alteration /replacement ❑ Other: CATEGORY OF CONSTRUCTION Note: Permit fees* are based on the total value of the work performed. Indicate ❑ 1 & 2- Family dwelling KCornmercial/Industrial the value (rounded-to the nearest dollar) of all equipment, materials, labor, overhead and profit for the work indicated on this application. _ ❑ Accessory Building [II Multi-Family ' ' ❑ Master Builder ❑ Other: Valuation $ JOB SITE INFORMATION and LOCATION No. of bedrooms: No. of baths: Job site address: i D ,St>J Pfttint. iluz•( Total area number floors 1 S 3 1 New dwelling area (sq. ft.) Suite #: Bldg. /Apt. #: Garage /carport area (sq. ft.) Project Name: i- t OT (.e.Sr u r_A-&)rt— Covered porch area (sq. ft.) Cross street/Directions to job site: Deck area (sq. ft.) Other structure area (sq. ft.) (IS t Sw f eke -tr-ic t4-`'1 REQUIRED DATA: COMMERCIAL - USE CHECKLIST Subdivision: Lot #: Tax map /parcel #: Note: Permit fees* are based on the total value of the work performed. Indicate DESCRIPTION OF WORK the value (rounded to the nearest dollar) of all equipment, materials, labor, overhead and profit for the work indicated on this application. t1P 6-,2A- OF Type / t e- t Ct1-' '$7r h) 0 '3 iO CZ- 380 ge uf2/4tF 0yS Valuation $S 367. Gk0 Existing building area (sq. ft.) New building area (sq. ft.) Number of stories ❑ PROPERTY OWNER I XI TENANT Type of construction Occupancy group(s): Existing: M{— Name: L.0 ( i.) New: Address: 1 1' 30 5L3 VF td.- 14 w-i City /State /Zip: j 1 C,AiZ 82 9 `7ZZ3 NOTICE: All contractors and subcontractors are required to be Phone:5o's 2_14G ilo55 Fax: licensed with the Oregon Construction Contractors Board under ❑ APPLICANT CONTACT PERSON provisions of ORS 701 and may be required to be licensed in the Business Name: }{- 1�Pr �t'q Ut es-7 ri- jurisdiction where work is being performed. If the applicant is exempt Contact Name: M &L,)) i) from licensing, the following reason applies: Address: 1 1 53b 5t PAC■ FLC- `r' City /State /Zip: TlCyA OR_ 9 7 223 Phone:?, - 24 (,- L4c5 Fax: BUILDING PERMIT FEES *. E -mail: Please refer to fee schedule. CONTRACTOR , Business Name: Fro 5t-2_ 5-61E5 ..'< (CE" i^--)t.. Fees due upon application $ Address: Z3 ( ^-) -nu-6-w'c c City /State /Zip: Porn- ,0 , biz_ 41 1221 Amount received $ Phone: 5e3- Zy g -tciyg Fax: 5c3 -4 - 7 6 7 Date received: CCB Lic. #: p6 / V}a WV-10a Authorized ��� Notice: This permit application expires if a permit is not obtained within Signature: //` - /.---e-f-s•-t___ Date: 180 days after it has been accepted as complete. ,# V ( /L.' /14,4 _J *Fee methodology set by Tri- County Building Industry Service Board. (Please print name) i:\Dsts\Permit Forms\BldgPermitApp.doc 01/03 Fire Protection Permit Check List A.) ❑ New ❑ Addition ❑ Alteration ❑ Repair B.) Modification to sprinkler heads only: Describe work to 1. 1 -10 heads: No plan review required. be done: 2. 11+ heads: Plan review required. Number of sprinkler heads: Additional description of work: Type of :System (Complete:A,:B >orf.C.as applicable) A.) Sprinkler Wet ❑ Dry ❑ Standpipes Additional Hazard Group Information Density Design Area K. Factor Sprinkler Project Valuation: $ B.) Type I - Hood Fire Suppression System Hood Project Valuation $ 150 C.) Fire Alarm Submittal shall Battery Calculations Yes ❑ include: Individual Component Yes ❑ Cut Sheets Fire Alarm Project Valuation: $ Project Valuation Subtotal (A, B & C): $ 3 So° Permit fee based on valuation (see chart): $ 8L7v 8% State Surcharge: $ C, S4 FLS Plan Review 40% of Permit: $ 32e TOTAL: $30214 02 Plan review requires a completed application and 3 sets of plans at submittal. Plan review fees are required at submittal. "New" fire protection systems require that plans bear the original seal of an Oregon licensed fire suppression engineer, or NICET level "3" technicians. is \dsts \forms \FPSchecklist.doc 11/21/01 4 City of Tigard, Oregon • 13125 SW Hall Blvd. • Tigard, OR 97223 { March 15, 2004 Af,1; t • GO RE: FIRE SUPPRESSION SYSTEM 4 s k { z Project Information �F"� r X7 , 0 . rJ63;t�acl J_ Building Permit: BUP2007 -00249 Construction Type: VN Tenant Name: Hi Hat Restaurant Occupancy Type: A Address: 11530 SW Pacific Highway The plan review was performed under the State of Oregon Mechanical Specialty Code (OMSC) 2007 edition; the State of Oregon Fire Code (OFC), 2007 edition; and NFPA 96. The submitted plans are approved subject to the following. • Each automatic fire suppression system shall have both automatic and manual actuation means. A manual activation device shall be located at or near a means of egress from the cooking area, a minimum of 10 feet and a maximum of 20 feet from the kitchen exhaust system. The manual activation device shall be located a minimum of 4 '/2 feet and a maximum of 5 feet above the finished floor. 509.3 OMSC • The actuation of the automatic fire suppression system shall automatically shut down the fuel or electrical power supply to the cooking appliances. The fuel and electrical power supply reset shall be manual. 509.4 OMSC • A portable fire extinguisher shall be provided within a 30 foot travel distance of the cooking equipment. A Class K rated extinguisher is required if the cooking equipment involves vegetable or animal oils or fats. Section 904.11.5 OFC • Wet- chemical systems shall be inspected and tested at 6 -month intervals. Carbon Dioxide & Clean -agent systems shall be inspected and tested at 12 -month intervals. Sections 904.5, 904.8 & 904.10 OFC. • A hood exhaust fan(s) shall continue to operate after the extinguishing system has been activated unless fan shutdown is required by a listed component of the ventilation system or by the design of the extinguishing system. 8.2.3.1 • All deep -fat fryers shall be installed with at least a 406 mm (16 in.) space between the fryer and surface flames from adjacent cooking equipment. 12.1.2.4 • Where a steel or tempered glass baffle plate is installed at a minimum 203 mm (8 in.) in height between the fryer and surface flames of the adjacent appliance, the requirement for a 406 mm (16 in.) space shall not apply. 12.1.2.5 Approved Plans: 1 set of approved plans, bearing the City of Tigard approval stamp, shall be maintained on the jobsite. The plans shall be available to the Building Division inspectors throughout all phases of construction. 106.4.6 OMSC Phone: 503.639.4171 • Fax: 503.684.7297 • www.tigard- or.gov e TTY Relay: 503.684.2772 When submitting revised drawings or additional information, please attach a copy of the enclosed City of Tigard, Letter of Transmittal. The letter of transmittal assists the City of Tigard in tracking and processing the documents. Respectfully, di -.1■1111r,•■•,_ op, o Dan Nelson, Senior Plans Examiner / k'S t n Lo' r--¢t C 'rk 3 Hauser Sales & Service, Inc. PENED PEN Phone: 503- 248 -1948 231 N. Tillamook Fax: 503- 248 -7077 Portland, Oregon 97227 y - 3 'L 1 CC2 11(4382-k MA RD Date: WILDIVIG Technician: Account: k ��'C i `)'rW U2►� . T Will Call: Delivery: Bill To: Telephone: Ship To: \ S 1Jf\ C\ i� L New Account: Contact: 71 (IA- 2 l Z2-3 Purchase Order: 1. 2. 3. 4. DESCRIPTION / WEIGH, 6 — YEAR RECHARGE HYDROTEST/ PART NUMBER INSPECT & TAG MAINTENANCE RECHARGE (46o 0 S) ( - 2 7 r X /0 r 2 A-O P - - 3 r 2 A Q O N o Z z -C S _N:r r_ :11 . _� .►. DLtT srzC << 2 Approved ....._.,.�. �... 1 5(1 2:7 R-s) P No iZ�ES LcItar for Follow i 2- 1°I'xlq` 2 = ADP a•-C S Attached slif-11110110000Staisto Doi � �OU�+.�c -�s ,�. _�.� -'. a t - .. c i b ( t2 t,.) -r e ( (a t Z_ 30 ' ^' �.J � 1c5 = - I '- 2- (' ,4 o 2 z -g-coo 2- A PPL► /Nac E 36, - ' 6/ (- /Z u/ ,J 2Z L/ (5' <<7- PF(z - = t- F S 2- Z-7 = uPQcc -10-1 ec a cs (- E A-DP , J 0 Z-e F ra rer 2 4-J Alezz.LE -s P0/1-' 7S f 7 ,' (o vas Remarks: Items in columns 2, 3 and 4 have been removed to our shop for additional work. Number of loaners left: CUSTOMER SIGNATURE OFFICE COPY \ V (6s) 1 f-tIDOel] ib• I. Cd0-11.01 A ujoime. o'it, , i 2 q•is ,,,,s... Ve , tc., . ( ____ jt j_ , (-, • I , 11 :. t,b --7) , 4..} - - - r 3 c , 0 , 1 • (3 c . . 6 Cli. ii 4\ PC . CII) :0-0-411 / - p INN, . I. • )- .1/4._ • op A-00 ,, . 7 • _____. --_, -...„__. -------- - - _,...1 • , , 1 A .■ .1, • ,Q,„ c #2,63 , IL .4a • 1, AZ ID' .' r __. • , .. :. . / , - '-'-"---- 0/ ,,,,, P: ' --- • Oa L / z ,.,- 0 , 2._ e / 3 6 ,,, // .. to ( iZtcot..z. 0 ' ----- ---.„2 r ' is , y (..,,,s6e..... ■ ...- ■ (Z '`' . 1 te- . . • (gl A ftcr Component Description 2 -2 CONTROLS 2 -2.1 XV' Control System, P/N 87- 120099 -001 The XV Control System, P/N 87- 120099 -001, is used for actuating the Kidde Cylinder and Valve Assembly. The XV Control System can be attached to the System Valve Actuator, P/N 87- 120042 -001 for direct cylinder mounting, or to a wall for remote mounting. Knockouts are provided to accommodate either type of mounting. The controller can be operated with: • Automatic mechanical detection (fusible -links and thermo -bulb links), • Automatic electrical operation, and • Remote and local manual operation. 1 it -J . 9 -7/16 in. ; . �, ■ i : . i (240 mm) -c7 < c 1 , �I ; ,,, , ,..„... i i i f' - i , . , . .. , _ ,' 0 - -,..‘ .- , , , , , ) . „ .. .:- • ,..: : . ,.. . , , .... 0: 1.... ..A. rit . ._ 3 -3/4 in. —_p. 4 8 -3/16 in. (95 mm) (208 mm) En— Figure 2 -14. XV Control System, P/N 87- 120099 -001 P/N 87- 122000 -001 2 -13 September 2006 ' Component Description , `/ f A f3., B TOP OF ` i CENTER OF CYLINDER VALVE 1 DISCHARGE PORT t z > > SI t i. .. L ' J r 3'y4 __....... -. 'IS C _ NOMINAL CYLINDER DIAMETER Figure 2 -1. Dimensions of Cylinder and Valve Assembly, P/N 87- 12XXXX -001 Refer to Figure 5 -26 for Cylinder Valve details. Table 2 -1. Cylinder and Valve Assembly Specifications Cylinder and Valve Maximum Dimensions Assembly Number Part Model Flow Number A B C 87- 120001 -001 WHDR -125 4 15 -1/4 in. 13 -3/4 in. 8 in. (387 mm) (349 mm) (203 mm) 87- 120002 -001 WHDR -260 8 21 in. 19 -5/8 in. 9 in. (534 mm) (498 mm) (230 mm) 87- 120003 -001 WHDR -400S 12 19 in. 17 -1/2 in. 12 -1/4 in. (483 mm) (444 mm) (311 mm) 87- 120006 -001 WHDR -400M 12 24 -3/8 in. 23 in. 10 in. (619 mm) (584 mm) (254 mm) 87- 120005 -001 WHDR -600 18 35 -1/8 in. 33 -3/4 in. 10 in. (892 mm) (857 mm) (254 mm) 87- 125001 -001 WHDR -5EU 4 15 -1/4 in. 13 -7/8 in. 8 in. (381 mm) (352 mm) (203 mm) 87- 125002 -001 WHDR -10EU 8 21 in. 19 -5/8 in. 9 in. (533 mm) (498 mm) (229 mm) 87- 125003 -001 WHDR -S15EU 12 18 -7/8 in. 17 -1/2 in. 12 in. (479 mm) (445 mm) (305 mm) 87- 125006 -001 WHDR -M15EU 12 24 -3/8 in. 23 in. 10 in. (619 mm) (584 mm) (254 mm) 87- 125005 -001 WHDR -23EU 18 35 in. 33 -1/2 in. 10 in. (889 mm) (851 mm) (254 mm) P/N 87- 122000 -001 2 -3 September 2006 Component: Description 2;1.1.1 CYLINDER BRACKETS A -4. CYLINDER STRAP CYLINDER STRAP 1 METAL 17 UUIIIIIIIf } /fitllllllll/ 115 / T I Al r lar t - I lf! �PdHlillI11111111IIIIIIItk1 t111Nf11171711111111111U11 1 B B ii ♦ __, ♦ I'_1 _ r 1 t —C —►I FRONT VIEW SIDE VIEW Figure 2 -2. Mounting Brackets Table 2 -2. Mounting Bracket Dimensions — Dimensions Part No. Model A B C 60- 9197430 -000 WHDR -125 3 in. 9 -3/8 in. 1 -3/8 in. WHDR-5EU (76 mm) (238 mm) (35 mm) 60- 9197263 -000 WHDR -260 4 -1/2 in. 12 in. 2 -1/2 in. WHDR 1OEU (114 mm) (305 mm) (64 mm) 60- 9197414 -000 WHDR -400M 4 -1/2 in. 20 -1/2 in. 2 -1/2 in. WHDR-M15EU (114 mm) (521 mm) (64 mm) 60- 9197415 -000 WHDR -400S 4 -1/2 in. 11 -1/2 in. 2 in. WHDR 515EU (114 mm) (290 mm) (51 mm) P/N 87-122000-001 September 2006 2 4 System•Design 4 ft. NOZZLE .,• (1.2 m) DUCT ,/ '. 4 ft. DUCT (1.2 m) ,/ 4 ft. : ( ) 1.2 m t 7 3r1 NOZZLE � '- r` 1 0ft. \� 20 ft. (3 m) ft (6 m) NOZZLE (1.2 m)�./ "V" FILTER BANK COVERAGE 111��� "V" FILTER BANK COVERAGE 10 ft. (3 m) PLENUM 20 ft. (6 m) PLENUM �o• NOZZLE -- 3/4 H 1 L I H. "V" FILTER BANK COVERAGE (END VIEW) 4 ft. NOZZLE (1.2 m) 4 e 7 • DUCT 4 ft. DUCT 4 ft. (1.2m) r ' +'" (l %,: NOZZLE r$• \\ (3 : m) 20 A` (6 mft ) 4 ft. (1.2 m)> NOZZLE SINGLE FILTER BANK COVERAGE SINGLE FILTER BANK COVERAGE 10 ft. (3 m) PLENUM 20 ft. (6 m) PLENUM -0 11/3 Wk- s 3/4 H -1 I / 14 SINGLE BANK FILTER COVERAGE (END VIEW) Figure 3 -28. ADP Protection Nozzle, P/N 87- 120011 -001 September 2006 3 -34 P/N 87- 122000 -001 System Design • 3 -6.1.1 DUCTS The ADP nozzle, P/N 87- 120011 -001, is used for protection of the exhaust ductwork. The duct cross section can be any shape, not including obstructions (i.e., round, square, or rectangular) and the duct itself can be of unlimited length. In accordance with NFPA 96, the exhaust fan should be left running at the time of system discharge. This will help to remove smoke and other airborne materials and gases from the hazard area in the event of a fire. Check with the Authority Having Jurisdiction for local requirements. A damper, if present, should be left open at system discharge. However, if the damper is closed, the system designer must insure that additional nozzles are required. 3- 6.1.1.1 Protection of Ducts 0 to 50 inches in Perimeter One ADP nozzle, P/N 87- 120011 -001, is required for protection of a duct with a perimeter up to 50- inches (refer to Figure 3 -29). Length of duct is unlimited. The nozzle is located at the geometric center of the cross - sectional area that it is protecting, and is located in the duct within six inches of the entrance. Note: All Kidde systems are listed by UL for use with the exhaust fan either on or off when the system is discharged. DUCT HOOD DUCT PERIMETER UP TO AND INCLUDING 50 In. (1270 mm) 11.78 in. (300 mm) 15.91 In MAX. DIAGONAL (404 mm) 4 MAX. 9" � I 12.5 in. 11.78 in. (300 mm) (316 mm) A t MAX. DIAGONAL Mir SQUARE DUCT RECNGU TALAR U DCT 2 "A" + 2 "B" = 65 irC mm) ROUND DUCT • 4. OF VERTICAL DUCT Q I ADP NOZZLE ♦ VERTICAL/HORIZONTAL DUCT f— AIM POINT 1I - II 0 -6 in. (0- 152mm) ADP NOZZLE DUCT ENTRANCE 4 Q OF HORIZONTAL DUCT 2 to 4 in. (51 to 102 mm) I NOZZLE TIP to DUCT HIP Figure 3 -29. Duct Protection Using Single ADP Nozzle, P/N 87- 120011 -001 P/N 87- 122000 -001 3 -35 September 2006 System Design 3= 6.1.1.2 Ducts 50 to 100 inches in Perimeter Two ADP nozzles, P/N 87- 120011 -001, pointing in the same direction are required for protection of ducts with perimeters greater than 50 inches and less than or equal to 100 inches. Ducts can be of unlimited length (refer to Figure 3 -30). For other option of ducts up to 75 perimeter inches (See Figure 3 -32). Note: All Kidde systems are listed by UL for use with the exhaust fan either on or off when the system is discharged. DUCT HOOD X )' X • 'Y +x %2x I , , Y4d 1 /2d MAX. DIAMETER 31.83 in. (809 mm) /aX /2X • Go NOZZLES TO BE ALONG ONE 25 in. (635 mm) CENTERLINE AT THE 1/4 POINTS. MAX. SIDE pi, C. or c, ' • NOZZLES TO BE 0 - 6 in. (0 -152 mm) UP FROM ENTRANCE OF VERTICAL DUCT MAX. DIAGONAL 11.78 in. (300 mm) MAX. DIAGONAL TYP. (2) ADP NOZZLES 11.78 in. (300 mm) SQUARE RECTANGULAR R OUND ADP NOZZLE 0 to 6 in. _ 1(0 to 152 mm) • DUCT ENTRANCE Pc OF VERTICAL DUCT j ® — — - T. OF HORIZONTAL DUCT 2 - 4 in. (51 mm -102 mm) ADP NOZZLE AIM POINT NOZZLE TIP TO DUCT HIP VERTICAL/HORIZONTAL DUCT Figure 3 -30. Duct Protection Using Two ADP Nozzles, P/N 87- 120011 -001 September 2006 3 -36 P/N 87- 122000 -001 System Design • 3 -6 VENTILATION 3 -6.1 Plenums Table 3 -29. Plenum Protection Items Parameters ADP Nozzle No Filter 1 10 ft. x 4 ft. (3 m x 1.2 m) Max. 1 - located at one end of the plenum "V" Filter 10 ft. x 4 ft. (3 m x 1.2 m) 1 - located at one end of the plenum 20 ft. x 4 ft. (6 m x 1.2 m) 2 - located at end of plenum pointing inwards Single Bank Filter 10 ft. x 4 ft. (3 m x 1.2 m) 1 located at one end of the plenum 20 ft. x 4 ft. (6 m x 1.2 m) 2 - located at end of plenum pointing inwards 1 When no filters are present, the nozzle protecting the plenum is used to discharge the wet chem- ical on the underside of the hood. In this case, the hood may not exceed a length of 10 ft. (3 m) or a width of 4 ft (1.2 m). Longer plenums may be similarly protected with a single ADP nozzle being used for each 10 ft. (3.0 m) of plenum length and each 4 ft. (1.2 m) of plenum width. ADP nozzles may be used in combinations (see Figure 3 -28). Multiples may be installed facing in the same direction, and /or at the ends of the plenum pointing in. Each nozzle shall provide a maximum of 10 ft. (3 m) of coverage. ADP nozzles must be centrally located in the plenum with their discharge directed along the length of the plenum and located in relation to the filters as shown in Figure 3 -28. P/N 87- 122000 -001 3 -33 September 2006 System Design 3 -4.13 Upright Broilers Table 3 -19. ADP Nozzle Coverage Area Items Parameters Broiler Compartment With Maximum Internal 30 -1/4 in. x 34 in. (768 mm x 864 mm) Horizontal Dimensions Nozzle Aim Through grill toward the center of the grease drain -off opening Nozzle Location Within the top 4 in. (102 mm) of space in the broiler compartment. Commonly mounted near the front opening and directed inside the broiler o BROILER _ EXHAUST COMPARTMENT ` I M G DUCT VE GRILL 4 in. (102 mm) MAX. +.—. 30 -1/4 in 34 in (864 mm) —t.. 768 mm MAX. ; MAX. • GREASE .1 - GREASE DRAIN PAN I DRAIN -OFF 7 FRONT C , (BROILER DOOR REMOVED) RIGHT SIDE NOTE: DIMENSIONS SHOWN ARE INSIDE BROILER COMPARTMENT ADP NOZZLES SHOULD BE MOUNTED ON THE PERIMETER OF THE BROILER TOP (SHADED AREA). IT SHOULD BE DIRECTED THROUGH THE GRILL TOWARD THE CENTER OF THE GREASE DRAIN -OFF OPENING. NOZZLE DISCHARGE SHALL NOT BE OBSTRUCTED BY ANY STRUCTURAL PART OF THE BROILER. Figure 3 -15. ADP Nozzle Placement for Upright Broilers September 2006 3 -20 P/N 87- 122000 -001 System.Design 3 -4.21 Wok Table 3 -27. GRW Nozzle Coverage Area Items Parameters Wok Diameter 14 in. to 28 in. (356 mm to 1829 mm) Wok Depth 3 in. to 8 in. (76 mm to 508 mm) Nozzle Aim Center of Wok Nozzle Location — Must be over center and within 2 in. (51 35 in. (889 mm) Min. mm) from center and nozzle height must be measured over center and within 2 in. (51 mm) from center from inside 56 in. (1422 mm) Max. bottom of Wok. Only one nozzle per Wok. MAX. OFFSET ONE GRW NOZZLE MUST BE LOCATED ANYWHERE WITHIN THE SHADED AREA AIMED AT CENTER OF WOK 56 in. (1422 mm) MAX. 14 in. (356 mm) TO ► 28 in. (711mm) DIAMETER 35 in. (889 mm) T / CENTER OF HAZARD MIN. l AREA AT BASE WOK 3 in. (76 mm) TO 8 in. (203 mm) DEPTH INSIDE BOTTOM OF WOK Figure 3 -23. Wok September 2006 3 -28 P/N 87- 122000 -001 • System Design • 3 -4.20 Griddle — Flat Cooking Surface (With or without Raised Ribs) Table 3 -26. ADP Nozzle Coverage Area Items Parameters Maximum Hazard Area 30 in. x 42 in. (762 mm x 1067 mm) Nozzle Aim At a point 3 in. (76 mm) from the midpoint of hazard area Nozzle Location — any point on the perimeter of 13 in. (330 mm) Min. appliance 48 in. (1219 mm) Max. Note: Positioning the nozzle directly over the appliance is not permitted. AIIIL 48 in. . (1219 mm) MAX. 30 in. ,. (762 mm) �/ 13 in. MAX (330 mm) MIN. TOP OF APPLIANCE AIM POINT: 3 in. (76 mm) RADIUS FROM 42 in. THE MIDPOINT OF HAZARD AREA (1067 mm) MAX. Figure 3 -22. Griddle - Flat Cooking Surface P/N 87- 122000 -001 3 -27 September 2006 • • System Design 3 -4.9 Four Burner Ranges Table 3 -13. R Nozzle Coverage Area — Four Burner Range Items Parameters Maximum Hazard Area 28 in. x 28 in. (711 mm x 711 mm) Nozzle Aim Midpoint of Hazard Area Nozzle Location — Anywhere within the area of a 20 in. (508 mm) Min. circle generated by a 9 in. (229 mm) radius about the midpoint 42 in. (1067 mm) Max. Note: Shape of burner not important. 18 in. (457 mm) DIA. 1 42 in (1067 mm) MAX. (FROM TOP OF RANGE) • A'R' NOZZLE MAY BE LOCATED ANYWHERE WITHIN THE SHADED AREA 20 in. (508 mm) MIN. I (FROM TOP OF AIM POINT: MIDPOINT OF RANGE) HAZARD AREA / 28 in. (711 mm) • ' Ir...., v.. MAX. HAZARD S4-'' 14 in. (356 mm) MAX. AREA LENGTH BURNER CENTERLINE / _'� � \ C\ TO CENTERLINE 1 VW i ii_0 14 in. (356 mm) MAX. BURNER CENTERLINE TO CENTERLINE 4 28 in. (711 mm) MAX. ---0. HAZARD AREA WIDTH Figure 3 -10. R Nozzle Coverage for a 4- Burner Range P/N 87- 122000 -001 3-15 September 2006 System Design 3 -4.1 Single Vat Deep Fat Fryer With Drip Boards Table 3 -2. F Nozzle Coverage Area • Items Parameters Maximum Hazard Area 18 in. x 18 in. (457 mm x 457 mm) Maximum Appliance Area (with drip board) 18 in. x 23 in. (457 mm x 584 mm) Nozzle Aim Midpoint of hazard area Nozzle Location (from top of appliance at an angle of 45 or 27 in. (686 mm) Min. more from the horizontal) 45 in. (1143 mm) Max. AN F NOZZLE MAY BE LOCATED ANYWHERE WITHIN THE GRID 45 in. (114.3 mm) MAX. DIAGONAL FROM AN F NOZZLE MAY BE LOCATED ANYWHERE AIM POINT WITHIN THE GRID 45 in. (1143 mm) 4011114ftimidrip 45 in. (1143 mm) MAX NOZZLE LOCATION ? F� 45 OR MORE FROM HORIZONTAL AIMPOINT: ` r E 27 in. ♦0 ' ' MIDPOINT OF (686 mm) MIN • • MIA •• # / HAZARD AREA %.-- 18 in. (457 mm) 23 in. AIM POINT: MAX. (584 mm) MIDPOINT OF MAX. HAZARD AREA i • HAZARD AREA DRIP BOARD \� DRIP BOARD 18 in. (457 mm) ►I MAX. 23 in. (584 mm) MAX. APPLIANCE AREA FRONT VIEW SIDE VIEW Figure 3 -2. Single Vat Deep Fat Fryer September 2006 3 -6 P/N 87- 122000 -001 Component Description 2 =211.1 SYSTEM NITROGEN CARTRIDGE, P/N 87- 120043 -001 The XV Control System uses a nitrogen cartridge for actuating the wet chemical cylinders and is charged with dry nitrogen (see Figure 2 -15). The cartridge is mounted inside the XV Control System to protect it from tampering and provides the date of manufacturing and space (gray band) for recording the installation date. 4 5 -1/8 in. (130 mm) er 1 -9/16 in. x .f (40 mm) �, I III�II��II _ j . { .tom GRAY BAND Figure 2 -15. System Nitrogen Cartridge, P/N 87- 120043 -001 2 -2.1.2 TEST CARTRIDGE, P/N 87- 120044 -001 The Test Cartridge is used for testing of the Kidde Wet Chemical System. The cartridge has a red band and labeled "TEST CARTRIDGE" as shown in Figure 2 -16. Note: The System Nitrogen Cartridge P/N 87- 120043 -001 is required for actuation and full discharge or "puff" tests. The Test Cartridge (P /N 87- 120044 -001) must be removed and the System A Nitrogen Cartridge (P /N 87- 120043 -001) must be installed at the completion of CAUTION any work done on the system. Failure to do so will result in malfunction of the system. 4 in. (102 mm) TEST 'c" 1 M. r,A. �N11I1OI (25 mm) I CARTRIDGE y viv Figure 2 -16. Test Cartridge, P/N 87- 120044 -001 September 2006 2 -14 P/N 87- 122000 -001 Component Description , 2.1 1:3.3 GRW Nozzle, P/N 87- 120013 -001 GRW nozzles are used for the following hazards: • Woks • Electric Charbroiler (Open Grid) • Radiant Charbroiler INTERNAL THREAD 3/8 in. NPT --\ �} 7.� �8 'n /48 y i '''- :„ :, ,, 4/ 13/16 in. (21 mm) 4, 3 GROOVES i 9/16 in. (14 mm) Figure 2 -8. GRW Nozzle, P/N 87- 120013 -001 2- 1.1.3.4 R Nozzle, P/N 87- 120014 -001 R nozzles are used for the following hazard: • Ranges INTERNAL THREAD — \ 4 3/8 in. NPT /(...,.. ` 4 ( 4g q, 4: //i 4 13/16 in. (21 mm) - . ' 4 GROOVES 9/16 in. (14 mm) Figure 2 -9. R Nozzle, P/N 87- 120014 -001 September 2006 2 -10 P/N 87- 122000 -001 Comfonent Description Table 2 -5. WHDR Nozzles Nozzle Type Part Number Flow Number Grooves ADP Nozzle 87- 120011 -001 1 1 / sr -,q q , F Nozzle 87- 120012 -001 2 2 GRW Nozzle 87- 120013 -001 1 3 11 R Nozzle 87- 120014 -001 1 4 1 ,,,,,,!....17 �1r 151 ; '; t'-. DM Nozzle 87- 120015 -001 3 0 z • psi -f iii LPF Nozzle 87- 120022 -001 2 1 & 4 zz,cy z. r ,�..: +sl LPR Nozzle 87 120024 - 001 1 Disc & Core September 2006 2 -8 P/N 87- 122000 -001 - • 1 . Component Description • '2- 1 .1.3.1 ADP Nozzle, P/N 87- 120011 -001 ADP nozzles are used for the following hazards: • Ducts • Plenums • Flat cooking surfaces (griddle) • Split Vat Deep Fat Fryers (low proximity) • Upright Broilers (Salamander) • Closed -top Chain Broilers • Open -top Chain Broilers • Natural /Mesquite Charcoal Charbroiler • Krispy Kreme Model 270 d/h Donut Fryer INTERNAL THREAD --- 3/8 in. NPT /off �� ''/8 � • (48 ti ' ' vs,..: 'a 13/16 in. (21 mm) �,r' 1 GROOVE 9/16 in. (14 mm) Figure 2 -6. ADP Nozzle, P/N 87- 120011 -001 2- 1.1.3.2 F Nozzle, P/N 87- 120012 -001 F nozzles are used for the following hazards: • Fryers • Tilt Skillets /Braising Pans • Pumice Rock (Lava, Ceramic) • Charbroilers INTERNAL THREAD / 3/8 in. NPT / � (4 8 f� E - 'n i �i% 13/16 in. (21 mm) ` ,:.' .� 2 GROOVES 9/16 in. (14 mm) Figure 2 -7. F Nozzle, P/N 87- 120012 -001 P/N 87- 122000 -001 2 -9 September 2006