Specifications 7245 FUNDAMENTALS OF FIRE ALARM SYSTEMS A,)p ZC1 7,-0CsZ. Record of Completion Name of Protected Property DICKS SPORTING GOODS 0342 Address: 9402 SW WASHINGTON SQUARE ROAD Rep. Of Protected Prop. (name/phone): STORE MANAGER Authority Having Jurisdiction: City of TIARA Orel Number: 13125 SW HALL BLVD TIGARD, Oregon 97223 1. Types) of System Service: OFFICE COPY NFPA 72, Chapter 3 — Local If alarm is transmitted to Iocetion(s) off premise, list where received: ADT SECURITY SERVICES INC 14200 E. EXPOSITION, AURORA, CO 00012 NFPA 72, Chapter 3 — Emergency VoicelAlarm Service Quantity of speakers installed Quantity of speakar zones -RECEIVED Quantity of�or in NFPA 72, Chapter 4 — Auxiliary Indicate type ofeonnection: JAN 2 4 2008 Local energy, Shunt, + """iel telephone Location and telephone number for receipt of signals' CITY OF TIGARD NEPA72, Chapter 4 — Remote Station BUILDING DIVISION NFPA 72, Chapter 4 — Proprietary If alarms are retransmitted to public service communications a nder or others, indicate location and telephone mmrber of the orgaairation receiving alarm: Indicate how alarm is retransmitted: d NFPA 72, 4 — Central Station - The Prime Contractor. ADT SECURITY SERVICES, INC Central Station Location: ADT SECURITY SERVICES, INC 14200 E. EXPCSMON, AURORA, CO 60012 Means of trssan of signals from the protected promise to the central station: McCulloh Multiplex Once -Way Radio Digital Alarm Communicate - - Two-way Radio Others Means of transmission of alarms to the public fire service communications center (a) TELCO (b) TELCO System Location: Electrical cage by loading dock area on the main floor Organization Name/Phone ADT-1-888-230.2666 Representative �Name/Phone DUTY Installer ADT SECURITY SERVICES. INC 513.469 -7110 KEN KRAUS 503-469-7212 Supplier ADT SECURITY SERVICES, INC 503-469-7110 KEN KRAUS 503-469 -7212 Service; Organization ADT SECURITY SERVICES, INC 1-800-429-7124 KEN KRAUS 503-469 -7212 Location of Record (As -Bmlt) Drawings: ON SITE WIMANAG$IR Location of Owners Manuals: ON SITE W/MANAGER Location of Test Reports: ADT CNC A Contract, dated , for test and inspection accordance with NFPA standard(s) No.(s) 72 ,dated , is in effect. (NONE) • '72-26 NATIONAL EIRE AIARIVI CODS 2. Certification of System installation (Fill out after installation is complete and wiring checked for opens, shorts, ground finks, and improper branching, but prior to gs) This system has been installed in accordance with the NFPA standards as listed below, was inspected by oat X , includes the devices listed below and has been in service since ADT sac. ► EIERVMES,W1C NFPA n, Chapters OO 3 ®®0® (circle all that apply) N FPA 70, National Electrical Code, Article 760 J Manufacturer's Insttractions Other (specify): Signed Date: 1- 11.2008 Organization: � ' ;' INC 3. C.ertification of System Ohs All operational features and functions of this system were tested by ADT SECURITY SERVICES, INC. on 1-11-2008 and Found to be operating properly in accordance with the requirements of NFPA 72, Chapters 03®000 (circle all that apply) � 4 N FPA 70, Naziorwl Electrical Code, Article 760 — 1 M anufacturer's Instructions Other (specify): NONE Signed: Date 1- 13- 2088 ACT SECURITY __ _,5 lane ... .. ....... ....,.<... 4. Alarm Initiating Devices and Circuits (Use blanks to indicated quantity of devices.) MANUAL a) 9 Manual Stations Noncoded, Activating Transmitters Coded b) Combination Manual Fire Alarm and Guard's Tour Coded Stations AUTOMATIC Coverage: Complete: Partial: X a) 11 Smoke Detectors _ Ian 11 Photo b) S t) Duct Detectors Ion /O Photo ¢ Heat Detectors _ Fr RR 6 FT/RR. RC d) 2 Sprinkler Water Flow Switches Noncoded, activating ' Transmitters Coded o) Other (list) 5. Supervisory Signal Initiating Devices and Circuits (Use blanks to indicated quantity of devices.) GUARD'S TOUR a) Coded Stations b) Noncoded Stations Activating Transmitters c) Compulsory Guard Tour System. Ccnoprisad of Transmitter Stations Intermediate Stations and Node: Combination devices recorded under 4 (b) and 5(a). SPRIN SYSTEM a) _ _ Coded Valve Supervisory Signaling Attachments 3_ _ Valve Supervisory Switches Activating — Transmitters b) Braiding Temperature c) Site Water Temperature Points Site Water Supply Level Points Electric Pump: e) Pump Running f) Controller Off (AC Loss) g) AC Phase Reversal Engine - Driven Fire Pump: h) Engine Running k) Engine trouble i) ._,._ Controller Off 1) Low Fuel j) Controller Tmuble m) Fuel Spill Engine – Driven Generator: n) Selector in Auto Position o) Control Panel Trouble p) Transfer Switches q) Engine Running 72-27 FUNDAMENTAL OF FIRE ALARM SYSTEM Other Supervisory Function(s) (specify) 6. Alarm Notification Appliances and Circuits Types and Quantity of alarm indicating appliances installed: a) 1 Bells Inds (8) _ Speakers b) ROM ___ e) Chimes 4) Other: e) Ng Visual Signals Type HORN/VISUAL 88 with inuele 17 without =Mile f) I Local itimunciator 7. Signaling Line Circuits: Quantity and Style (See NFPA 72, Table 3-6.1) of signaling line circuits connected to system: Quantity. 1 Style B S. System Power Supplies: a) Primary (Main) 120vac Nominal Voltage: 120VAC Current 3.2 AMPS Rating: Overcurrent Protection: Type DEIXCATED BREAKER Current 20 amp Rating: Location: Receiving MS b) Secondary (Standby)c Storage Battery: Amp Hour litatinx 2 (12 Al Calculated capacity to drive system, in holm: 24 60 Engine - driven plumbs* dedicated to fire alarm system: c) Location of fael storage: Emergency or Standby System used as backup to primary Pow e Supply, instead of using a Secondary Power Supply" Emergency System described in NFPA 70, Article 700 Legally Required Standby System dem-Riad in NFPA.70, Miele 71 Optional Standby described in NFPA 70, Article 702, which. aLso meets the performance requirements of Athol' e 700 or 701 9. System Software a) Operating System Software Revision Level(s): N/A b) Application Software Revision Level(s): NIA c) Revision Completed by. NIA (mow) (fina) 10. Comnumts (Signed) for Central Station of Alarm Service Company (title) (date) Frequency of routine tests and inspections, if other than in accordance with the referenced NFPA standard(s): NONE System deviations from the referenced NFPA standard(s) are (Signed) for canal Station ofAlarm Service Oampany (title) (date) Upon completion of the system(s) satisfactory test(s) witnessed (if required by the authority having jurisdiction): X (Signed) representative of authority having jurisdiction (title) (date) Figure 1-72.1 Record of Completion (=tinned).