Loading...
Report Oct, 2. 2008 3:47PM No. 3410 P. 2 nsTaNVEY'' All Activity Report Security Solution: / , - 06 2 Page 1 of 2 Activity from 10/01/08 to 10/02/08 with open /close activity. 1116824909 GREENBURG SPACE CENTER 11105 SW GREENBURG RD TIGARD, OR 97223 503 - 624 -2052 Date Day Panel Zone Event/Comment/Area 10/01/08 02:01 Wed AT ALARM PERIODIC TEST REPORT AUTO TEST 10/01/08 02:02 Wed AT ALARM PERIODIC TEST REPORT AUTO TEST 10/01/08 14:29 Wed 4 ALARM WATER FLOW RISER #2 10/01/08 14:29 Wed ALARM ACK PIX: 1 10/01/08 14:29 Wed FIRE TUALATIN FIRE 5035201357 10/01/08 14:29 Wed SYS COMM USER 10/01/08 14 :29 Wed SYS COMM LINDA MUNOZ 10/01/08 14:29 Wed IN TEST MO 000:02:30 ALL ZONES 10/01/08 14:29 Wed CALL RES ANSWER 10/01/08 14:30 Wed COMMENT DID NOT COMPLETE DISPATCH 10/01/08 14:30 Wed COMMENT PER LOG 10/01/08 14:30 Wed 4 RESTORE WATER FLOW RISER #2 10/01/08 14:30 Wed OUST ERROR FALSE FIRE 10/01/08 14:30 Wed CALL RES ANSWERING MACHINE 10/01/08 14:30 Wed CALL RES LEFT MESSAGE 10/01/08 Wed 2 ALARM WATER FLOW RISER #1 10/01/08 14:32 Wed 2 RESTORE WATER FLOW RISER #1 10/01/08 14:33 Wed 2 ALARM WATER FLOW RISER #1 10/02/08 18 :37 Oct. 2. 2008 3:47PM j ,, No. 3410 P. 3 1 )0(7b 0 - ) 0 (X) e Page 2of2 Date Day Panel Zone Event/Comment/Area 10/01/08 14:33 Wed 2 RESTORE WATER FLOW RISER #1 10/01/08 14:34 Wed 3 ALARM FIRE SUPERVISORY RISER #1 10/01/08 14:34 Wed 3 RESTORE FIRE SUPERVISORY RISER #1 10/01/08 14 :34 Wed 5 ALARM FIRE SUPERVISORY RISER #2 10/01/08 14:34 Wed 5 RESTORE FIRE SUPERVISORY RISER #2 10/01/08 14:35 Wed 7 ALARM FIRE SUPERVISORY MAIN VALVE 10/01/08 14:35 Wed 7 RESTORE FIRE SUPERVISORY MAIN VALVE 10/01/08 14:35 Wed 8 ALARM FIRE SUPERVISORY MAIN VALVE 10/01/08 14:35 Wed 8 RESTORE FIRE SUPERVISORY MAIN VALVE 10/01/08 14:36 Wed 6 ALARM PULL STATION FACP 10/01/08 14:36 Wed 6 RESTORE PULL STATION FACP 10/01/08 14:38 Wed 1 ALARM SMOKE FACP SMOKE 10/01/08 14:39 Wed 1 RESTORE SMOKE FACP SMOKE 10/01/08 14:39 Wed TMSG TROUBLE SYSTEM SHUTDOWN TROUBLE MESSAGE 10/01/08 14:40 Wed TMSG RESTORE SYSTEM SHUTDOWN TROUBLE MESSAGE 10/01/08 17:02 Wed OUT OF TES ALL ZONES 10/02/08 02:01 Thu AT ALARM PERIODIC TEST REPORT AUTO TEST 10/02/08 02:02 Thu AT ALARM PERIODIC TEST REPORT AUTO TEST 10/02/08 15:35 Thu QUALITY REPORT FAXED e mailed to the cam melody 10/02/08 18:37 Conventional Monitored Fire Alarm System - Record of Completion CMFA -ROC blank.doc Protected Premise: Owner's Rep & Phone: Greenburg Space Center The Robison Family Trust 11125 SW Greenburg Road Tigard, OR 97223 1. Type(s) of System or Service: Local (per NFPA 72, Chapter 3) Remote Supervising Station (per NFPA 72, Chapter 4) Monitoring Provided By: Stanley Convergent Security Solutions, Inc. Phone (for testing): Number of Phone Lines: '2. Means of Transmission: y c t Alarm Codes: Co..nac —'c. "�S> This system was designed by, and equipment supplied by: Northwest Fire suppression, Inc., 15385 SW Beaverton Creek Court Beaverton, OR 97006 Phone: 503 - 644 -7720 Location of "as built" drawings, owner's manual, test reports, and maintenance records: A contract for test and inspection in accordance with NFPA 72, 7 -3.2: (check one) is in effect. X. Owner has declined test and inspection contract at this time. Comments: 7r,L•g, c■S (record of completion — page 2) Z.C. .) v V `-. cf 2. Record of System Installation: (Lead installing technician or electrician to complete prior to acceptance testing) This system has been installed in accordance with the National Electric Code, and meets all requirements of Article 760 as a Power Limited Fire Alarm system. After all device installation was complete (except control equipment final terminations), all initiation, signal and control circuit wiring was tested and found to be free of opens, shorts and ground faults. The entire system was installed per the AHJ approved plans, and complete, accurate "as built" notations have been provided to Northwest Fire Suppression, Inc. Exceptions: Installing Contractor 6\ W�S-c Responsible Journeyman ^Z)t1/4 License # t-l L Signatur �-- v — Date 5 -D 3. Record of System Operation: (Responsible testing technician to complete prior to acceptance testing) All operational functions and features of this system were tested and found to be working properly in accordance with the approved plans, per NFPA 70, National Electric Code, Article 760, per NFPA 72, Chapters 1, 3, 4, 5, 6 and 7, and per the manufacturer's instructions. I have reviewed the "as built" drawings and find that they are accurate and complete. Exceptions: Certifying Contractor 1.1-cW FS; toa Responsible Technician �p\a License # 1{3c\ LF, Signature tea, T�,_ � Date 1- - -f -OS (record of completion —page 3) p 24' 0 5 - oc �J � 4. Alarm Initiating Devices (indicate quantities) Manual Stations Ionization Smoke Detectors \ Photoelectric Smoke Detectors Photoelectric Duct Detectors Other Smoke / Flame Detectors, type Fixed Temperature Heat Detectors Fixed Temperature Heat / Rate of Rise Detectors Rate Anticipated or Compensated Heat Detectors Feet of Linear Heat Detector Z Sprinkler Waterflow Switches Other Initiating Devices (i.e. satellite panels, hood systems, etc.) List them: 5. Supervisory Signal Initiating Devices (indicate quantities) Sprinkler Valve Tamper Switches Sprinkler Low Air Pressure Switches Other Supervisory Switches (i.e. fire pump, water supply, generator, etc.) List them: 'Z — ° Z3 - 7 (record of completion — page 4) 6. Alarm Notification Appliances and Circuits (quantities) Notification Circuits (Zones) Horn / Strobes Strobes (only) Horns (only) Bells Other (list them) Annunciators 7. Signaling Line Circuits (Addressable Systems Only) Quantity: N/A Style: N/A 8. System Power Supplies Fire Alarm Control Panel: Primary (Main): Nominal Voltage 120 VAC Breaker Current Rating: 'Amps Is this a dedicated branch circuit, with the disconnect means mechanically protected, and with a red marking (per NFPA 72, 1- 5.2.5.2)? Yes or No y Breaker Location:a..� Secondary (Standby): Sealed Lead Acid Batteries, 12 Amp Hrs. Providing (24, 60 or 90) 60 Hrs. Or Emergency Standby System (U.P.S.): (check as applies) NA Per National Electric Code, Article 700 Per National Electric Code, Article 701 Per National Electric Code, Article 702 (plus Article 700 or 701) Notification Expansion Panels: NA Primary (Main): Nominal Voltage 120 VAC Breaker Current Rating: _ Amps Is this a dedicated branch circuit, with the disconnect means mechanically protected, and with a red marking (per NFPA 72, 1- 5.2.5.2)? Yes or No Breaker Location(s): Secondary (Standby): Sealed Lead Acid Batteries, Amp Hrs. Providing (24, 60 or 90) Hrs. (record of completion —page 5) LOLA � ' (--J ZJ� 9. System Software Operating System Software Revision Level (on IC): N/A Application Software Revision Level: N/A Revision Completed (Installed) By: N/A Company: N/A 10. Comments System Deviations From the Referenced NFPA Standards (list if any): 11. Acceptance Testing Statements Commissioning Technician: I have tested and witnessed satisfactory performance of all system devices and control functions, and/or have noted any exceptions on this Record of Completion. Date l -- ZS - Local Authority (or Authorities) Having Jurisdiction: This system has been inspected and is accepted for the jurisdiction I represent. Name ' Representing C T K---(i Comments: 4 1004 t )C -; (/v ` a-G 0 Signed Date \ OA A -I S. Name Representing Comments: Signed Date