Permit tr CITY OF TIGARD ELECTRICAL PERMIT
4 7 COMMUNITY DEVELOPMENT PERMIT #: ELC2006 -00696
`' DATE ISSUED: 12/7/2006
,TG AR,D, 13125 SW Hall Blvd., Tigard, OR 97223 503.639.4171
PARCEL: 2S104AC - 03900
SITE ADDRESS: 12647 SW 133RD AVE ZONING: R -25
SUBDIVISION: MORNING HILL NO. 8. LOT : 183 JURISDICTION: TIG
Project Description: Install generator wiring.
RESIDENTIAL UNIT TEMP SRVC /FEEDERS MISCELLANEOUS
1000 SF OR LESS: 0 - 200 amp: PUMP /IRRIGATION:
EACH ADD'L 500SF: 201 - 400 amp: SIGN /OUT LINE LTG:
LIMITED ENERGY: 401 - 600 amp: SIGNAL /PANEL:
MANF HM/ SVC/ FDR: 601 +amps - 1000 volts: MINOR LABEL (10):
SERVICE /FEEDER . BRANCH CIRCUITS ADD'L INSPECTIONS
0 - 200 amp: 1 W /SERVICE OR FEEDER: PER INSPECTION:
201 - 400 amp: 1st W/O SRVC OR FDR: PER HOUR:
401 - 600 amp: EA ADD'L BRNCH CIRC: IN PLANT:
601 - 1000 amp: PLAN REVIEW SECTION
1000+ amp /volt: > =4 RES UNITS: > 600 VOLT NOMINAL:
Reconnect only: SVC /FDR >= 225 AMPS: CLASS AREA/SPEC OCC:
Owner: Contractor:
MICHAEL STEFFEN CLACKAMAS ELECTRIC INC.
12647 SW 133RD AVE PO BOX 51
TIGARD, OR 97223 BEAVERCREEK, OR 97004
Phone: 503 - 521 - 1906 Contact #: PRI 503 - 632 - 2420
FAX 503 - 632 -2421
FEES
Description Date Amount Reg #: ELE 3 - 606C
[ELPRMT] ELC Permit 12/7/2006 $80.30 LIC 161932
[TAX] 8% State Surcharge 12/7/2006 $6.42 SUP 5041S
Total $86.72 REQUIRED ITEMS AND REPORTS
This Permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable laws. All
work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for
more than 180 days. ATTENTION: Oregon law requires you to follow rules adopted by the Oregon Utility Notification Center. Those rules are set forth in
OAR 952 - 001 -0010 through OAR 952 -001 -0100. You may obtain copies of these rules or direct questions to OUNC at 503.246.6699 or 1.800.332.2344.
Issued By: �, 41:( , Permittee Signature: _ e -e s ,c k
OWNER INSTALLATION ONLY
The installation is being made on property I own which is not intended for sale, lease, or rent.
OWNER'S SIGNATURE: DATE:
CONTRACTOR INSTALLATION ONLY
SIGNATURE OF SUPR. ELEC'N: DATE:
LICENSE NO:
Call 503.639.4175 by 7:00 a.m. for an inspection that business day.
This permit card shall be kept in a conspicuous place on the job site until completion of the project.
Approved plans are required on the job site at the time of each inspection.
DEC -2006 10:03A FROM:CLACKAMAS ELECTRIC 5036322421 TO : 5035981960 P.2'2
Electrical Permit t�>Rplicat F �� � '� ,'
IVE �x tt ! ll B Ba r .,�
City of Tigard '� Datcc/B : - a - 1 2 1 --),4' Permit No. � , � A A 13125 SW Hall Blvd„ Tigard, OR 97223 E r ® 00 6 pla R rip a n 1 Other Permit:
Phone: 503.639.4171 Fax: 503.598.196(1 Date/By:
`l l e,.Rivlj' Inspection Line: 503.639.4175 Date Randy /By: kris. See Page 2 for
, Internet: www.tigard-or.gov CITY Gi='I i A�tD Notified/Method: ' Supplemental Information
BUIW1 niIISION
TYPE OF WORK PLAN REVIEW
Place check all that apply (submit a scIs of plans w /itans checked below).
❑ New construction ® Addition /alteration /replacement
❑ Service or feeder 400 amps or more 0 Building over three stories.
❑ Demolition ❑ Other: where the available fault current ❑ Marinas and boatyards.
CATEGORY OF CONSTRUCTION exceeds 10,000 amps at 150 volts or ❑ Floating buildings.
less to ground, or exceeds 14,000 ❑ Commercial -use agricultural
® 1- and 2- family dwelling ❑ Commercial /industrial ❑ Accessory building amps for all other installations. buildings.
❑ Multi- family ❑ Master builder ❑ Other: ❑ Fire pump. ❑ Installation of 75 KVA or
JOB SITE INFORMATION AND LOCATION ❑ Emergency system. larger separately derived system.
❑ Addition of new motor load of ❑ "A ", "E ", "1- 2 ", "1 -3 ",
Job no.: Job site address: 12647 SW 133 Ave. 1001Ip or more. occupancy.
❑ Six or more residential units. ❑ Recreational vehicle parks.
City/State /ZIP: Tigard, OR. 97223 ❑ Health -care facilities. ❑ Supply voltage for more than
❑ Hazardous locations. 600 volts nominal,
Suite/bldg. /apt. no.: Project name: ❑ Service or feeder 600 amps or more,
FEE SCHEDULE
Cross street/directions to job site: Description 1 Qry. 1 Fee. 1 Thud 1 •
New residential single- or multi - family dwelling unit.
Includes attached garage.
Subdivision: 1 Lot no.: 1,000 sq. 11. or less 145.15 4
Ea. add'I 500 sq. ft. or portion 33.40 1
Tax map /parcel no.: Limited energy, residential
DESCRIPTION OF WORK (with above sq. I) 75.00 2
Install generator wiring Limited energy, multi - family 75 00 2
g g residential (with above sq. ft.)
Services or feeders installatlon and /or location
200 amps or less / 80.30 , Xi, 0 2
❑ PROPERTY OWNER -l. ❑ TENANT 201 turps to 400 amps 106.85 2
Name: Michael Steffen 401 amps to 600 amp 160.60 2
601 amps to 1,000 amps 240.60 2
Address: 12647 SW 133" Ave. Over 1,000 amps or volts 454.65 2
City/State/ZIP: Tigard, OR. 97223 Temporary services or feeders installation, alteration, and/or
relocation
Phone: (503)521 -1906 Fax: ( ) 200-amps'511ess
Owner installation: This installation is being made on property that I own which is not 201 amps to 400 amps 100.30 2
intended for sale, lease, rent, or exchange, according to ORS 447, 449, 670, and 701. 401 amps to 599 amps 133.75 2
Branch circuits - new, alteration, or extension, per panel
Owner signature: Date: A. Fee for branch circuits with
® APPLICANT I ❑ CONTACT PERSON above service or feeder fee,
each branch circuit 6.65 2
Business name: Clackamas Electric Inc. B. Fee for branch circuits
Contact name: Scott Johnston witho service or feede fee 46.85 2
first branch circuit
Address: PO Box 51 Each add'l branch circuit 6.65 _ 2
Miscellaneous (service or feeder nut included)
City /State /ZIP: Beavercreek, OR. 97004 Each manufactured or modular 90.90 2
dwelling, service and/or feeder
Phone: (503) 969 -5684 Fax: : (503) 632 - 2421 Reconnect only 66.85 2
E - mai l: Pump or irrigation circle 53.40 2
CONTRACTOR Sign or outline lighting 53.40 2
Signal circuit(s) or limited-
Business name: Clackamas Electric Inc. energy panel, alteration, or
Address: PO Box 51 extension. Describe: Page 2 2
City/State /ZIP: Beavercreek, OR. 97004 Each additional inspection over allowable in any of the above
Per inspection 62.50
Phone: (503) 632 -2420 I Fax: (503) 632 -2421 Investigation per hour (1 hr min) 62.50
CCI3 Lic.: 161923 I Electrical Li : 3 -606C Suprv. Lic.: 5041S Industrial plant per hour 73.75 _
Suprv. Electrician signature, required: D ELECTRICAL PERMIT FEES
Subtotal: t:
Print name: Scott Johnston ate: 12/05/06 Plan review (25 %of permi fee) •
State surcharge (83/4 of permit fee): se35 - 6 , .if
Authorized signature: TOTAL PERMIT FEE: .72
Print name I Date: Thu permit application expires if a permit is not obtained within 180
days after It has been accepted ea complete. ,=-/ 1 �f
• Number of inspections allowed per permit. 6 I
I:\ Building \Perms ELC- Pn'miiApp.doe 05/9/06 4404615T(lI/US /COM/WEB
CITY OF TIGARD .
BUILDING DIVISION 1 PERMIT #: F; 02006.00696
13125 SW Hall Blvd., Tigard, OR 97223 DATE ISSUED: 12/7/2006
Phone: (503) 639 -4171 '�, r i I
Inspection Requests (24 Hrs.): (503) 639 -4175 ,4,41- I"'I_IL
INSPECTION WORKSHEET FOR DATE: 12/812W6 TIME: 7 :01Atvi PAGE: 7
SITE ADDRESS: 17647 SW 133RD AVE CLASS OF WORK:
SUBDIVISION: MORNING HILL NO, 8 LOT #: 183 TYPE OF USE:
PROJECT NAME: STEFFEN
DESCRIPTION: Instal! generator wiring.
OWNER: s'I °EN, MICHAEL PHONE #: 503 -57l -15)06
CONTRACTOR: CLACKAMAS ELECTRIC INC. PHONE #: 503-632..2420
Inspection Request Scheduled For: Date: 12/8/2006 Pour Time:
Code # Inspection Description Confirm # Contact # Message
199 Electrical final 040863-01 503- 969-56kW Y
Corrections /Comments/ Instructions:
XI -2
a Pg -ovtoo sveA4pttf L F6a_ pLixo vistN okz.ctlt -x.a .
NO e S c.6N)cp `Tor t, -1-1.-ILAc t N m �. 4- 6 3(\5'2.
Nth G-R,( 3 01 i 1, — C(zizzG coNs6 au
q Tpc,..„,-,i s-g:y—, c.... Rii-cr- e()k•)teff\ Li "I 01_
,„.-,,,,,,„. 6 (A)11 A ,- tc.- P•R_\)1
f ir :d , Nit C__1 ?...P� Nv.- i N a i CZ-(, ?..3 .
— Nu-61 _,G).)—mistae.K. w4 Cc c rs us': I?-I 0 4
N 6N
PASS ❑ PARTIAL APPROVAL ❑ CANCEL n NO ACCESS
FAIL CALL FOR INSPECTION 1 1 ADDITIONAL FEES ASSESSED
Inspector: C R N 66 m- ---- Date: 1 2 1 1 2)( E, Phone #: (503) 718- 9147_
• CITY OF TIGARD
BUILDING DIVISION PERMIT #: EI.-C20O6- 0Q6BE5
13125 SW Hall Blvd., Tigard, OR 97223 ► DATE ISSUED: 12/7/2006
Phone: (503) 639 -4171 0 11
Inspection Requests (24 Hrs.): (503) 639 -4175
INSPECTION WORKSHEET FOR DATE: 1/22/2007 TIME: 7 :0OAM PAGE: 3
SITE ADDRESS: 12€41 SW 133RD AVE CLASS OF WORK:
SUBDIVISION: MORNING HILL NO. B LOT #: 103 TYPE OF USE:
PROJECT NAME: STEFFEN
DESCRIPTION: Install venerator wiring.
OWNER: STEFFEN, MICHAEL PHONE #: 503 -521 -1906
CONTRACTOR: CLACKAMAS ELECTRIC INC. PHONE #: 503 - 632 -2420
Inspection Request Scheduled For: Date: 1r2 :Y3007 Pour Time:
Code # Inspection Description Confirm # Contact # Message
19 Electrical final 042363 - 01 603 N
Corrections /Comments/ Instructions:
i
aki L-a. acs . C - -
VW
Q
` ASS • PARTIAL APPROVAL ❑ CANCEL N CCESS
v, •� � L 1 C' . FOR INSPECTION ❑ ADDITIONAL FEES ASSESSED
Inspector: G IS be L Date: 1 1 09 Phone #: (503) 718- 2�
1
CITY OF TIGARD
BUILDING DIVISION PERMIT #:uCZ00b.
13125 SW Hall Blvd., Tigard, OR 97223 DATE ISSUED: It/ ?dt
Phone: (503) 639 -4171 �} i
Inspection Requests (24 Hrs.): (503) 639 - 4175
INSPECTION WORKSHEET FOR DATE: 12,1 2,b i ( TIME: PAGE:
SITE ADDRESS: 2 641 S W 133 AV . CLASS OF WORK:
SUBDIVISION: LOT #: TYPE OF USE:
PROJECT NAME: TT E F-£14,
DESCRIPTION:
OWNER: MtC‘k kEl.. PHONE #:
CONTRACTOR: CLI\c, AS i PHONE #:
Inspection Request Scheduled For: Date: tZI 214 01 Pour Time:
Code # Inspection Description Confirm # Contact # Message
■ c `AL- .
Corrections /Comments /Instructions:
?(Lo Z - R.ZA I Li ACGE 4 ■8L'E' 1'AP GEN(Z.‘) c.X' 11 sc_oANa
P ~�cZ a CU 230. o (P')()
? t `zDZ-N -'--► Leo A wiTH P - 6 R , wANI NI' IAAv
. 2 . .
I PASS I PARTIAL APPROVAL CANCEL NO ACCESS
IX FAIL A CALL FOR INSPECTION f ADDITIONAL FEES ASSESSED
Inspector: G"An (46 Date: MI ViNo Phone #: (503) 718 - •
CITY OF TIGARD .
BUILDING DIVISION PERMIT #: ELC2006.00696
13125 SW Hall Blvd., Tigard, OR 97223 DATE ISSUED: -I 1/' 01)
Phone: (503) 639 - 4171 °'��, 'Itiili t
Inspection Requests (24 Hrs.): (503) 639 -4175
INSPECTION WORKSHEET FOR DATE: •12/20/2006 TIME: 7:00Am PAGE: •i0
SITE ADDRESS: .I )647 SW 133RD AVE CLASS OF WORK:
SUBDIVISION: MORNING HILL NO. 8 LOT #: 183 TYPE OF USE:
PROJECT NAME: STEFFEN
DESCRIPTION: Install generator wiring.
OWNER: STEFFEN, MICHAEL PHONE #: E,0'3..52•1_1906
CONTRACTOR: CLACKAMAS ELECTRIC INC. PHONE #: 5Q3 -632 -2420
Inspection Request Scheduled For: Date: /2170/2006 Pour Time:
Code # Inspection Description Confirm # Contact # Message
199 Elec :Irical final 041343 -02 503-718-2426 N
Corrections /Comments /Instructions:
2 30.`10 Vi 1 Di6ct�i S LL 1.i c 4
. i . i1' r 6 66:sTO 6(L Glo 6 .
30 A 2 N'o 'UM 6 to 6 to i t rGN Ski& &
fk via) A. W bP Ji
6 V I c, 6 D cSn rJ n5 [ .
vt;i1A 6 (.v+a vtNV, 66 & L VE
S i . c.
z. ®. (.6 0 S R ALL �3� Q ctt +l... AcQ .5 6 LE .
❑ PASS ❑ PARTIAL APPROVAL ❑ CANCEL n NO ACCESS
FAIL ❑ CALL FOR INSPECTION n ADDITIONAL FEES ASSESSED
Inspector: 16 6I 1,
1-+ [� Date: l'4 06 Phone #: (503) 718- 2 i f A
CITY OFTIGARD .
BUILDING DIVISION PERMIT #: ELC2006 -0069$
..:. - 13125 SW Hall Blvd., Tigard, OR 97223 DATE ISSUED: 12/7/200;
Phone: (503) 639 -4171 i
Inspection Requests (24 Hrs.): (503) 639 -4175 —!.i
INSPECTION WORKSHEET FOR DATE: 12/19/2006 TIME: 7:00AM PAGE: 25
SITE ADDRESS: 12647 SW 133RD AVE_ CLASS OF WORK:
SUBDIVISION: MORNING HILL NO 6 LOT #: 1133 TYPE OF USE:
PROJECT NAME: STEFFEN
DESCRIPTION: Install generator wiring.
OWNER: STEFFEN, MICHAEL PHONE #: 503..621_1906
CONTRACTOR: CLACKAMAS ELECTRIC INC. PHONE #: 503 -632 -2420
Inspection Request Scheduled For: Date: 12/19/7006 Pour Time:
Code # Inspection Description Confirm # Contact # Message
199 Electrical final 041276-01 503 - 969 -561 Y
Corrections /Comments/ Instructions:
&ZC-v ' re / V)...-0/4,
•
o
O kt 1
PASS ❑ PARTIA APPROVAL CANCEL ❑ NO ACCESS
n FAIL ❑ CA FOR I ■ r PE ice'' ❑ ADDITIONAL FEES ASSESSED
•
7 Inspector: .`fit Date: Phone #: (503) 718 -.)
CITY OF TIGARD ` , I: ;
BUILDING DIVISION PERMIT #:)r�C2
13125 SW Hall Blvd., Tigard, OR 97223 DATE ISSUED: 12. - . Zd 0 j
Phone: (503) 639 -4171 I I'
Inspection Requests (24 Hrs.): (503) 639 -4175
INSPECTION WORKSHEET FOR DATE: 12.-15 0 6 TIME: PAGE:
SITE ADDRESS: 12.641 SW 1 13 !2 AV. CLASS OF WORK:
SUBDIVISION: LOT #: TYPE OF USE:
PROJECT NAME: S FF'E1J
DESCRIPTION: G....6 00„476V,
, W� RItJ�
OWNER: PHONE #:
CONTRACTOR: c.La *v j s U PHONE #:
Inspection Request Scheduled For: Date: 12 -\ 5- Q(o Pour Time:
Code # Inspection Description Confirm # Contact # Message
Corrections /Comments/ Instructions:
t z a v ►OS to c t ( L E c _ I , ' S P ` A 1 . I R ► sW F O w (AZ 31) - 4 0 Lk 0
ms O OAK 91 311 (2 c ')
V Foci P1.3•14 kiE
Add + wo ETA i wEfl i s la rh►'C� t IckeCt Ev> - To N, i a 6 cAiES
11 c s w1 it 6 N s l' 6`ERN Af b•
t-mi' 5* .\) ► c_ �`Q b 200 A . i 5 ock tJ AI11■1) 6 �'
- CAz `OUtNb 7 G'(., 6 ANb \ N C,\..v t by Mt
11.NN ZEV ∎ w s oa .
The electrical installation defects noted
on this report shall be corrected and
an inspection request made within 20
calendar days per OAR 918- 271 -0030
❑ PASS ❑ PARTIAL APPROVAL ❑ CANCEL ❑ NO ACCESS
FAIL ❑ CALL FOR INSPECTION ❑ ADDITIONAL FEES ASSESSED
Inspector: Ctil 05 LE Date: , 1 00 Phone #: (503) 718 - 214$6
DEC;15 -2006 12:48P FROM:CLACKAMAS ELECTRIC 5036322441 T0:5036243681 P.1'5
•
xw
k .> , 4,, phone (503) 632 -2420
t ,544:4 � ' ; `�, , � fax (503) 632 -2421
PO Box 51
Beavercreek, OR 97004
Ellectinle inc. CCB #161923
License #3-606C
December 15, 2006
Attn: Gary Nobel — Senior Electrical Inspector
From: Scott Johnston — Clackamas Electric Inc.
Re: Here is the information Cessco provided me with in concerning the service disconnect.
Also here is my plan for the plan review.
Thank you,
Scott Johnston ' 4- " a -
if I
DEC 15 2006
Y Of liu
BIM' vivo Truicfnic
5 FA (cot 4 aWC)%Nb "c1 tS ON
RCvt= 1211 5f O
E Lc,20o4,- o0bgb
GIN .
DEC -•15 -2006 12:48P FROM:CLACKAMAS ELECTRIC 5036322421 TO:5036243681 P.2/5
12/14/2006 11:40 b0328 64284 J St.:U 1Nt.; rr Ell w
Oh : lig
S
V
;j , • 4 100 & 200 Amp 250 VAC ® 4O0 Amp 600 VAC
LS;MIE. 0441Il Min*aaS0,1 10911v ailkW g I C 9 1 9 .1W+3 Yl iW ,A.7 9.•2
DESCRIPTION
Generac RTS automatic transfer switches are designed
AUTOMATIC to operate with the Generac R- Series controller used on
TRAIJS SWIT the 1.5, 1.6, 2.4 and 3.0 liter Guardian Elite gaseous
generators. The transfer switche8 are UL 1008 listed
for standby operation.
tt tr InilaRair Mit m
STANDARD FEATURES
The standard 100.400 amp transfer switch is housed
in a steel NEMA 3R enclosure with electrostatically
applied powder paint. The Heavy Duty contactor is a
UL recognized device, designed for years of service.
The connection between the RTS end the Generator
control consists of 4 #14 contra . 'i - • • a neutral
wire. - Service Entrance rated transfer switches have
a UL sted T : n me c rcult • reaker ahea• o and in
back of the contactor for full downstream protection.
•
1.°r .At ir i. 4, 0 ,t.,,,, ...,, ,
' vow si p , 4,1r; leg Nir J.M NM , I 0 e .
wi. -4. Orkno;4 Li At"""4. . 4 % Y..xl.w.t0Y of'1:k 2 %
,:,26., by Generac Power Systems, Inc.
w ` COMMERCIAL. SERIES
DEC. 15 -2006 12:48P FROM:CLACKAMAS ELECTRIC 5036322421 TO: 5036243681 P.3'5
12/14/2006 11:40 5032884284 CESSCO INC 1•'ACat 112/ lad
FUNCTIONS RTS 100.400 Amp Transfer Switch
All Timing and sensing functions originate In the R- Series controller
Utility voltage drop.out <60%
Timer to generator start 15 seconds
Engine wean up delay 10 soconds
Standby votage sensor 90%
Utility voltage pldnie al
Re transfer time decay .. - _ 15 seconds
Engine cod -down timer tie seconds
Exerciser 15 minutes every 7 days
•
The transfer switch can ba operated manually without power awned.
SPECIFICATIONS \ \..7
, Amps 100 - 100 100 200 200 400
Voltage 120/240, 1 o 120)240, 1 o 1201240. le 120/240, 1 o 120)240, la
1201208, 3o 120/208, 3o _ 1201208, 30
2771480, 3o 2771480, 3e , -
Load Transition Type Open Transition Open Transition Open Transition Open Transiti Open Transition Open Transition
[Automatic!! Ser. Ent Rated Ser. Ent Rated
Enclosure f y,p _ NEMA 3R NEMA 3R NEMA 3R NEEMA 3R NEM A 3R NEMA 3R
Express Instal Kit Included _ No No No No
Withstand Rahn Amps ' 10,000 10,000 10,000 .. 10,040 . 10,000 18,000
Lu: Ran r e 210 • #14 400 MCM -114 800 MCM - #4 or 2.250 MCM-1/0
External Dimensions ( 'xW"x t
120/240,lo 20x15x7 24x13x7 20x15 24x15.9x7 36x24x10
•
120/208,30 24x20x7 24x20x7
277/480, 3s 36 x 24 x 10 48 x 3D x 12 •
Unit Weight Ube.) 35) 4B 85 50 35/48/105 55 88
J
TYPICAL CONNECTION
Generator RTS
N1 N1
N2 N2
Neutral - Neutral •
23 23
194 --- — 194
GENEpAC'' POWER SYSTEMS. INC. P .0. BOX 297 WI- IITEWATER, WI 53190 -
WESSITE: - usrdian.enerators.com
m os once oenemc Peanr Warts. Ins. NI rights usetvu . All Sadscatiovs ere sal to d+ANtp without noes
DEC. -15 -2006 12:49P FROM:CLACKAMAS ELECTRIC 5036322421 TO: 5E06243681 P.4/5
12/14/2006 11:40 5032884284 cttibl,Y1 1N1: rmi= C/o/ rta
http : / /www.guardiangenerators.com/ Products / Residential /Switch.AirCooled.aspx 11/15/2006
Transfer Switch
The transfer switch monitors utility power and signals the generator to start
when utility power is interrupted. When utility power returns, the transfer
switch returns the electrical load from the generator back to the utility. This
ensures your most important electrical loads are powered, within seconds, even
when you're away. Unlike other pre - packaged systems. GUARDIAN includes an
•
automatic transfer switch as Standard equipment with all models.
•
This transfer switch is the difference between a truly automatic generator set
and just another generator. No toggles to flip, no knobs to turn, no extension
cords to run when you lose utility power. You will have the comfort and peace -
of -mind knowing that your GUARDIAN standby generator does everything for
you... automatically.
• A two pole, 100 -amp automatic transfer switch is standard equipment on models 05336T.
• A two pole, 200 -amp automatic transfer switch is standard equipment on models 05324T and 05259T.
o A two pole, 200 -amp Service Disconnect transfer switch is standard equipment on model 05261T.
These transfer switches are also available for liquid- Cooled models or as an alternative to be purchased separately.
Standard Transfer Swit Service Disconnect Transfer Switch Click fQU-
Model Number • - 00A3 RTlSs- E -ZOOA3 S.Rec_Sheet
No. of Poles 2 2 I 1
Current Rating (amps) 100 200 + 1
60 Hz Phase Single Single
Voltage Rating (VAC) 250 250
Utility Voltage Monitor (fixed)
Pickup 604'0 80%
Dropout 60% 60%
Return to Utility 15 seconds 15 seconds
Service Disconnect Circuit Breakers (2) 100 Amp HACR Type (2) 200 Amp HACR Type •
Exerciser 15 min. weekly * Standard . Standard
UL 1008 Listed Standard Standard
Dimensions (H" x W" x 0") 23.5x13x7.4 23.5x1S.8x7.4
Enclosure Type NEMA 3R Outdoor Rated N MA 3R Outdoor Rated
Unit Wt. (Ibs.) 50 55
' Whon used wlth liquid- tooted models. tf used with alr- cooled models exercise du n will ye 12 minutes.
Copyright g 1998 - 2006 Generac Power Systems, Inc All rights reserved
Tra.. eft., Cn: +nl,r.w F . /'SiTAfV11sar A:.. 11
DEC -15 -2006 12:49P FROM:CLACKAMAS ELECTRIC 5036322421 TO: 5036243681 P. 5'5
1
`
�J
-.... r j
(------171 tit 4
1
V
3
a
N
4�
o 1
O
N .I°
�z
ix �
2
E.,,
1J
..,,.......,,,,,, I
r Y. 1
p • ita
•
9 "l
om
N i� w
i . 3... ti
kZ