Permit n; C O F 1"i BUILDING PERMIT
PERMIT D: BUP2008-00270
COMMUNITY DEVELOPMENT
DATE ISSUED: 8/11/2008
TfGARD3' 13125 SW Hall Blvd., Tigard, OR 97223 503.639.4171
PARCEL: 1S135BA-01802
SITE ADDRESS: 10101 SW WASHINGTON SQUARE RD ZONING: C - G
SUBDIVISION: WASHINGTON SQUARE TOO LOT: 025 JURISDICTION: TIG
PROJECT: BANK OF AMERICA
Project Description: Tear off, remove and replace.
REISSUE: FLOOR AREAS EXTERIOR WALL CONSTRUCTION
CLASS OF WORK: OTR FIRST: sf N: S: E: W:
TYPE OF USE: COM SECOND: sf PROJECT OPENINGS?
TYPE OF CONST: 5N sf N: S: E: W:
OCCUPANCY GRP: B TOTAL AREA: 0 sf ROOF CONST: FIRE RET?
OCCUPANCY LOAD: BASEMENT: sf AREA SEP. RATED:
STOR: HT: ft GARAGE: sf OCCU SEP. RATED:
BSMT ?: MEZZ ?: REQD SETBACKS REQUIRED
FLOOR LOAD: psf LEFT: ft RGHT: ft FIR SPKL: SMOK DET:
DWELLING UNITS: FRNT: ft REAR: ft FIR ALRM : HNDICP ACC:
BEDRMS: BATHS: IMP SURFACE: PRO CORR: PARKING:
VALUE: $ 37,370.00
Owner: Contractor:
WEIREX CO INC + ABC ROOFING CO INC
CCC PROPERTY MANAGEMENT LLC 10123 SE BRITTANY CT
14001 WILLAMINA CREEK RD CLACKAMAS, OR 97015 -8670
WILLAMINA, OR 97369
Phone: Contact #: PRI 503 - 786 - 0616
FAX 503 - 786 - 0642
Reg #: LIC 427
FEES
Description Date Amount REQUIRED ITEMS AND REPORTS
[BUILD] Permit Fee 8/11/2008 $299.62
[TAX] 12% State Surch 8/11/2008 $35.95
Total $335.57
This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other
applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of
issuance, or if work is suspended for more than 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the
Oregon Utility Notification Center. Those rules are set forth in OAR 952 - 001 -0010 through OAR 952 - 001 -0100. You may obtain a copy
of these rules or direct questions to OUNC by calling 503.246.6699 or 1.800.332.2344.
Issued By: ���� �� � ��� Permittee Signature: _ _ Cam
''
Call 503.639.4175 by 7:00 a.m. for an inspection that business day.
This permit card shall be kept in a conspicuous place on the job site until completion of the project.
Approved plans are required on the job site at the time of each inspection.
Bu;ding Perth Applicat
• Com mercial ® FOR OFFICE USE ONLY � '� � Received B �� t
City of Tigard ``�� a Date : � J Permit No: ' d [ (�
- 13125 SW Hall Blvd., Tigard, OR 97223 Qv Plan Review
Phone: 503.639.4171 Fax: 503.598.1 !!�� .�`1 ,�® ; ::te/By: Other Permit:
T 1 GA RD \
Inspection Line: 503.639.4175 � r � 1�. i By: s 0 See Page 2 for
Internet: www.tigard- or.gov � ,G 6 !\ Notified
ed /Mee TM, M Supplemental Information
TYPE OF WORK A , REQUIRED DATA: 1- AND 2- FAMILY DWELLING
❑ Demo ❑ New construction
e. Permit fees* are based on the value of the work perforated.
Indicate the value (rounded to the nearest dollar) of all
VI Addition/alteration /replacement ❑ Other. equipment, materials, labor, overhead, and the profit for the
CATEGORY OF CONSTRUCTION
work indicated on this application.
Valuation: $
❑ I - and 2- family dwelling 14 Commercial /industrial
❑ Accessory building ❑ Multi- family Number of bedrooms:
❑ Master builder ❑ Other. Number of bathrooms:
JOB SITE INFORMATION AND LOCATION Total number of floors:
Job site address: 10 I D 1 51,J Irja.S 000 �tt,t w Sev -r+- be • New dwelling area: square feet
City/State /ZIP: '1" l d Y . I D (L Garage /carport area: square feet
Suite/bldg. /apt. no.: Project name: Bd- V_ t , 4I , .41- %C«.. Covered porch area: square feet
Cross street/directions to job site: Deck area: square feet
Other structure area: square feet
REQUIRED DATA COMMERCIAL-USE CHECKLIST
Subdivision: Lot no.: Permit fees* are based on the value of the work performed.
Indicate the value (rounded to the nearest dollar) of all
Tax map /parcel no.: equipment, materials, labor, overhead, and the profit for the
10...,". DESCRIPTION OF WORK work indicated on this application.
- Teo c- io0 T A woo .0 e tc,� - t n S,Vgj � CIazS Valuation: $ � j 3 7 0
A / a , r n S t K 41 fly y ` ,Li Existing building area: square feet
� l Or I New building area: square feet
❑ PROPERTY OWNER ❑ TENANT Number of stories:
Name: p j 0 ,,,,, of --t- t t h , Type of construction:
Address: Occupancy groups:
City /State/ZIP: Existing:
Phone: ( ) Fax: ( ) New:
❑ APPLICANT ❑ CONTACT PERSON NOTICE
Business name: All contractors and subcontractors are required to be
Contact name: licensed with the Oregon Construction Contractors Board
under ORS 701 and may be required to be licensed in the
Address: jurisdiction in which work is being performed. If the
City /State /ZIP: applicant is exempt from licensing, the following reasons
apply:
Phone:( ) Fax::( )
E -mail:
CONTRACTOR
Business name: P 9--00C1 vl. C , BUILDING PERMIT FEES* it 7 . (_l
Address: ( b 1 St_ 6 „Al „,,, c4-..
(Please rclQtofeeschedute� o ld`
Structural plan review fee (or deposit): /in 75
City /State/ZIP: C ‘ CL t_k Ow.— <_ S Of-- 1`1015 /
I .1= R nlan rev� able): Mdi Trr annlic
Phone: (503 ) 7$ 6 - 0 6 % 6 Fax: (G 7 8.6 — o 64 •-4._ . 4 1 - 5 —
CCB lic.: 92:7 Total fees due upon application- -
Amount received: 3 ! ;5 57
Authorized signature: v /
\ This permit application expires if a permit is not obtained
i within 180 days after it has been accepted as complete.
Print name: MLLq� W aSVt1,V f 4A-- Date: 4 3 6 I p ° S * Fee methodology set by Tri- County Building Industry
Service Board.
I:\Building \Permits \BUP -COM PermitApp.doc 2/23/07 440- 4613T(11/02 /COM/WEB)
. e Zor-)V ,1 - :i ' : -, � ■) 1f h5,t ( t r ,'
City of Tigard Building Department ; ,
• • 13125 SW Hall Blvd., Tigard, OR 97223 Phone: (503) 639 -4171 . ' I:
Re-Roof Pre°i ns ecti®ra Report ®Il"m aT I G.AkRDA:
Requested by 1 Telephone f SZ 3) 3 L I — 1 (0 i g
Job Address / D / 0 / W - S Q • dz 7 .
Roof Access Location
Date Requested 16 . i,... S:. 0 8l Time Requested I" '-ci'f.,-'17. SQ nelor t
L e - -44:6-. 11- Type of Existing Roof ( �
1. Slope of roof deck kJ / foot (ratio) Z %
2. Roof/Penetrations/General Conditions IA Fair ❑ Poor
3. Are there blisters? Th Yes ❑ No
4. Are there cracks? 1,74.Yes ❑ No
5. Is there evidence of water ponding? Ig Yes ❑ No
6. Is moisture present under roofing (leak)? ❑ Yes $No
7. Is roof insulation existing? 0 Yes ,gNo
, tre693
8. Is roof insulation wet? ❑ Yes (No
9. Property line setbacks on all sides ? 10 feet 0. Yes ❑ No (_ i -
10. Roof Area $.< 6000 sq. ft ❑> 6000 sq. ft. --
�/
11. Building height 2 Stories 2 Stories
12. Class of roof required ❑ Non -rated B. ❑ C.
13. Type roof deck 1g Combustible ❑ Non - Combustible
14. Roof drains Provided ❑ Required ❑ Adequate
15. Overflow drains Jgi Provided ❑ Required ❑ Adequate
16. Attic ventilation Provided ❑ Required ❑ Adequate
17. Roof listing Provided ❑ Required
18. Scope of work tgl Tear off ❑ Overlay
To re -roof this structure the following conditions mu$t be met
t .CSC tCar " — 4S t
The re -roof proposal 1 • .� _: • , :,. for permit issuance if the conditions listed above are met. After obtaining your permit you must contact the
Building Division for an inspection when the roof deck is ready for the first inspection. The first inspection for a complete tear off is the deck
inspection. For a built -up roofing system (overlay), the first inspection is at the start of the job. After the re -roof is complete, a final inspection is
required.
Inspector E xt. v'7 2 ' 4 Date 7� ��/ 6
18uddrn Prenspection Report Form
d
SECTION 1506
FIRE CLASSIFICATION
1506.1 General. Roof assemblies shall be divided into the
classes defined below. Class A, B and C roof assemblies and
roof coverings required to be listed by this section shall be
tested in accordance with ASTM E 108 or UL 790. In addition,
fire- retardant - treated wood roof coverings shall be tested in ac-
cordance with ASTM D 2898. The minimum roof coverings in-
stalled on buildings shall comply with Table 1505.1 based on
the type of construction of the building. •
1506.2 Class A roof assemblies. Class A roof assemblies are
those that are effective against severe fire test exposure. Class A
roof assemblies and roof coverings shall be listed and identified r ?
• o as Class A by an approved testing agency. Class A roof assem- o c - . oo -. 3 - z C fm co 5
blies shall be permitted for use in buildings or structures of all F . a 3 g g - FT
types of co :n 8 � w w v -
-� ? to
Exception: Class A roof assemblies include those with cov o "' n 3- ? o 5 ' oo -
c e - - C
erings of brick, masonry, slate, clay or concrete roof tile, ex- m 0 o c 0 V °• F . Z
posed concrete roof deck, ferrous or copper shingles or C 3 3 ° ^ ; w _ C •
sheets. 2 c o' n o ' = o $ o0 0o > Z
15063 Class B roof a Class B roof assemblies are o �? a o n o O
those that are . effective against moderate fire -test exposure. - '' o ' ° y v ° N ' _a 3 = O •
Class B roof assemblies and ro coverings shall be listed and 9 x 0 n o . r ' ,./1 C7 co III n >
�. m N co
identified as Class B by an approved testing agency. ce -0 3 o 0. a= o CO < rn
Exception: Class B roof assemblies include those with cov- _ o 3 g o R a ` , co a A xi a
erings of metal sheets and shingles. °. —, c 3 C 2 3 O Z 0
1506.4 Class C roof assemblies. Class C roof assemblies are £ p, c -4 r c g . * . io n = c n . .
those t hat a effective against light fire -test exposure. Class C — 3 �' a o . s b is 3) r Q a.
roof assemblies and roof coverings shall be listed and identified g 3 a S N 3 Y o n N
as Class C by an approved testing agency. o w s —. 3 5 3 7 3 _ .. N
1506.5 Nonclassified roofing. Nonclassified roofing is ap- 0 ° ° : • < Z n
pro material that is not listed as a Class A, B or C roof cover- a 0 S o c- i Ft) Xa
mg o 8 H- E . w = n < 0
• shingles w ery D z
1506.6 Fire- retardant - treated woods le and shakes. ‘ ,7' , % , o _ i= _ o
c
Fire- retardant - treated wood shakes and shingles shall be treated ? s m —. — °°° d
DI. -0
by impregnation with chemicals by the full -cell vacuum -pres- o ° 3 ' 3 °, 3 n <
sure process, in accordance with AWPA CI. Each bundle shall N g Po 3 3 7 7 . y
be marked to identify the manufactured unit and the manufac-
turer, and shall also be labeled to identify the classification of the
material in accordance with the testing required in Section
I I 1506.6, the treating company and the quality control agency.
1506.7 Special purpose roofs. Special purpose wood shingle
or wood shake roofing shall conform with the grading and ap-
1 I plication requirements of Section 1508.8 or 1508.9. In addi-
tion. an underlayment of 0.625 -inch (15.9 mm) Type X
water- resistant gypsum backing board or gypsum sheathing
shall be placed under minimum nominal 0.5- inch -thick (12.7
mm) wood structural panel solid sheathing or 1 -inch (25 mm)
nominal spaced sheathing.
tG 6V�
��"���; CARLISLE'S 607;/0
�E
^ C , r .h erg i ' .
,.... us�n, „ 4. 8 Y 1. ® R F.N. a 1 ^.pax
T P:04^ - '
GUIDE -SPEC
Sure -Weld® TPO MECHANICALLY- FASTENED ROOFING SYSTEM
February 2006
This GUIDE -SPEC is a brief outline of Carlisle's Sure- 3. Projects with fasteners specified to exceed 12 ".
Weld Mechanically- Fastened Roofing System requirements and is
intended for use as a submittal with a bid package. Specifiers and 4. Air pressurized buildings, canopies and buildings with
the Carlisle Authorized Roofing Applicator must comply with the large openings where the total wall opening exceeds
"Design Criteria" and "Application" sections of Carlisle's 10% of the total wall area where openings are located.
Specifications prior to design or bid.
5. Cold storage buildings and freezer facilities.
PARTI GENERAL
1.01 DESCRIPTION 6. Projects where the membrane is expected to come in
direct contact with petroleum -based products or other
The Sure -Weld Mechanically- Fastened Roofing System chemicals.
incorporates 12', 10' or 8' wide, white, gray or tan 45, 60, 72 or 80-
mil thick scrim - reinforced Sure-Weld Thermoplastic Polyolefm B. Along with the project submittals (shop drawings and
(TPO) membrane. Insulation is mechanically fastened to an Request for Warranty), the roofing contractor must include
acceptable roof deck. Sure -Weld perimeter sheets (6', 5' or 4' wide pullout tests when:
respectively) are installed along the building edges and field
membrane sheets are mechanically fastened to the roof deck with 1. HP -X Fasteners are used through a lightweight
the appropriate Carlisle Fasteners and Fastening Plates. Adjoining insulating concrete substrate into a steel deck lighter
sheets of Sure-Weld membrane are overlapped and joined together than 22 gauge.
with a minimum 1 -1/2" wide hot air weld. Refer to the "Design
Criteria" section for the required number of perimeter membrane 2. HP -X Fasteners are used in conjunction with plywood
sheets and the required fastener spacing. decks less than 5/8" thick or oriented strand board
(OSB) minimum 7/16" thick.
1.02 QUALITY ASSURANCE
4. HP -NTB Fasteners are used in conjunction with
A. This roofing system must be installed by a Carlisle cementitious wood fiber and gypsum decks.
Authorized Roofing Applicator in compliance with shop
drawings as approved by Carlisle. There must be no C. For all projects (prior to project inspection by Carlisle) a final
deviations made without the PRIOR WRITTEN shop drawing must be approved by Carlisle.
APPROVAL of Carlisle.
1.04 PRODUCT DELIVERY, STORAGE AND
B. Upon completion of the installation, an inspection will be HANDLING
conducted by a Field Service Representative of Carlisle to
ascertain that the membrane roofing system has been installed A. Deliver materials to the job site in the original, unopened
according to Carlisle's published specifications and details containers labeled with the manufacturer's name, brand name
applicable at the time of bid. and installation instructions.
C. This roofing system meets Underwriters Laboratories (UL) B. Store Sure-Weld membrane in the original undisturbed plastic
and Factory Mutual (FM) requirements. For specific code wrap.
approvals achieved with this roofing system, refer to the
Sure -Weld Code Approval Guide, Factory Mutual Approval C. Job site storage temperatures in excess of 90° F may affect
Guide or Underwriters Fire Resistance and Roofing Materials shelf life of curable materials (i.e., adhesives and sealants).
and Systems Directories.
D. When liquid adhesives and sealants are exposed to lower
1.03 SUBMITTALS temperatures, restore to a minimum of 60° Fahrenheit before
use.
A. To ensure compliance with Carlisle's warranty requirements,
the following projects should be forwarded to Carlisle for E. Do not store adhesive containers with opened lids due to the
review prior to installation, preferably prior to bid. loss of solvent, which will occur from flash off.
1. Projects where a wind speed warranty coverage greater F. Insulation and underlay- ?, • •
than 55 MPH peak gusts is specified. ment must be stored so it is ,DA I L` L
kept dry and is protected " ` u ` -- `' ''"� " ". '' *'`' -'` `°"
2. Projects where the building height exceeds 50'. from the elements. Store Carlisle SynTec Incorporated
t
600319 SWMF Guide - 2/2006
– . ... —
insulation on a skid and completely cover with a breathable
material such as tarp or canvas. If the insulation is 2.02 MEMBRANE
lightweight, it should be weighted to prevent possible wind
damage. Sure-Weld white, gray or tan 45, 60, 72, 80 -mil thick reinforced
Thermoplastic Polyolefin (TPO) membrane is used for this system.
1.05 JOB CONDITIONS Field membrane sheets are 12', 10' or 8' wide by 100' long based
on project conditions. Perimeter sheets are 6' wide (used with 12'
A. This system must not be applied on projects where the slope field sheets), 5' wide (used with 10' field sheets) or 4' wide (used
exceeds 18" in one horizontal foot. When the roof slope with 8' field sheets). For physical properties of membrane, refer to
exceeds 5" per horizontal foot, use of an automatic welding page 4.
machine may be more difficult. A hand held welder should
be specified. 2.03 RELATED MATERIALS
B. Existing roofing material must be investigated by the Sure -Weld Non - Reinforced or Reinforced Flashing, Bonding
specifier and all wet material must be removed. Adhesive, Cut Edge Sealant, Water Cut -Off Mastic, PT 304
Sealant, EP -95 Spicing Cement, Weathered Membrane Cleaner,
C. Existing phenolic insulation and sprayed -in -place urethane Molded Pocket Sealant, Heat Weldable Walkway Pads, Pre -
roofs must be removed prior to installation of this system. Molded Inside /Outside Comers, Pipe Flashings, Curb Wraps and
Sealant Pockets.
D. The use of a vapor retarder to protect insulation and reduce
moisture accumulation within an insulated assembly should PART III EXECUTION
be investigated by the specifier. Consult the publications by 3.01 GENERAL
ASHRAE (American Society of Heating, Refrigerating and
Air - Conditioning Engineers, Inc.) and NRCA (National A. When feasible, begin the application at the highest point of
Roofing Contractors Association) for specific information. the highest roof level and work to the lowest point to prevent
moisture infiltration and to minimize construction traffic on
E. Coordination between trades is essential to avoid unnecessary completed sections. This will include completion of all
traffic over sections of the roof and to prevent damage to the flashings, terminations and daily seals.
membrane roofing system.
B. Follow criteria outlined in the "Design Criteria" section to
1.06 WARRANTY prepare the roof deck or the existing substrate prior to the
application of the new roofing system.
All warranties are available for commercial projects only.
3.02 ROOF DECK CRITERIA
A. A 5 or 10 year Membrane System Warranty, with a wind
speed coverage of up to 55 mph is available for a charge. A. Proper substrate shall be provided by the building owner.
The structure shall be sufficient to withstand normal
B. A 10 or 15 -year Total Roofing System Warranty is construction loads and live loads.
available for a charge on commercial projects. Projects will
receive a maximum peak gust wind speed coverage up to 55 B. Defects in the roof deck must be reported and documented to
mph unless prior review is performed by Carlisle regarding the specifier, general contractor and building owner for
an extended wind speed coverage. assessment. The Carlisle Authorized Applicator shall not
proceed with installation unless defects are corrected.
The 15 -year Warranty is not available for projects with
cementitious wood fiber or gypsum decks. C. Acceptable decks and the applicable Carlisle Fasteners:
Note: Due to various wind uplift coverages available, 1. Steel, 22 gauge or heavier - Carlisle HP -X
these projects must be reviewed by Carlisle prior to Fasteners/Piranha Plates or HP -Xtra Fasteners/Piranha
bid, preferrably in design phase, to determine Xtra Plates are required with a minimum pullout of 500
system enhancements that may be applicable. pounds per fastener.
C. A 20 -year Total System Warranty is available for a charge 2. Lightweight Insulating Concrete over steel - Carlisle
for projects utilizing minimum 60 -mil thick Sure-Weld HP -X Fasteners/Piranha Plates are required with a
membrane and incorporating additional design minimum pullout of 360 pounds per fastener (into steel
enhancements as outlined in "Attachment IV", 20 -Year deck below the lightweight concrete).
Warranty Design Enhancements, in the Sure-Weld Design
Criteria Specification. 3. Structural Concrete, rated 3,000 psi or greater —
Carlisle CD-10 or HD 14 -10 Fasteners (with Piranha
PART II PRODUCTS Plates) are required with a minimum pullout of 800
2.01 GENERAL pounds per fastener.
The components of this roofing system are to be products of 4. Wood Plank, minimum 15/32 thick Plywood - Carlisle
Carlisle or accepted by Carlisle as compatible. The installation, HP -X Fasteners/Piranha Plates are required
performance or integrity of products by others, when selected by
the specifier and accepted by Carlisle, is not the responsibility 5. On oriented strand board (OSB) decks, HP -X Fasteners
of Carlisle and is expressly disclaimed by the Carlisle Warranty. and Pirahna Plates may be used providing a pullout of
2
600319 SWMF Guide - 2/2006
360 pounds can be obtained. Please contact Carlisle's at those locations where Fastening Plates are located
Systems Design and Review Group sheet sizing and (along length of the membrane) and a minimum of 2" at
fastener spacing. end roll sections (width of the membrane).
6. Cementitious Wood Fiber and Gypsum - The Carlisle 4. Hot air weld the membrane sheets a minimum of 1 -1/2"
HP -NTB Fastener is required with a minimum pullout with an Automatic Hot Air Welding Machine.
of 300 pounds.
5. Membrane that has been exposed to the elements for
3.03 SUBSTRATE PREPARATION approximately 7 days must be prepared with Weathered
Membrane Cleaner. Wipe the surface where Weathered
A. On retrofit - recover projects, cut and remove wet insulation, Membrane Cleaner has been applied with a clean, dry
as identified by specifier, and fill all voids with new HP Splice Wipe or other white rag to remove cleaner
insulation so it is relatively flush with existing surface. residue prior to hot air welding.
B. For all projects, substrate must be even without noticeable C. Additional Membrane Securement
high spots or depressions, and must be free of accumulated
water, ice or snow. The membrane must be secured at the perimeter of each roof
level, roof section, expansion joint, curb, skylight, interior
C. Clear the substrate of debris and foreign material. Fresh wall, penthouse, etc., at any angle change which exceeds 2"
bitumen based roof cement must be removed or concealed. in one horizontal foot and at all other penetrations in
accordance with Carlisle's Details published with Carlisle's
3.04 INSTALLATION Specifications.
Refer to the applicable Material Safety Data Sheets and Technical D. Membrane Flashing
Data Bulletins for applicable cautions and warnings.
1. Flash all walls and curbs with Sure-Weld reinforced
A. Insulation Attachment membrane. Non - Reinforced membrane shall be limited
to inside and outside corners, field fabricated pipe seals,
1. Carlisle Insulation shall be mechanically fastened to the scuppers and Sealant Pockets where the use of pre-
roof deck as follows: molded accessories are not practical. Terminate the
flashing in accordance with an appropriate Carlisle SW-
a. For HP Recovery Board or minimum 1 -1/2" thick 9 Termination Detail.
Polyisocyanurate, a minimum of 5 fasteners and
plates per 4' x 8' board are required. 2. On vertical surfaces, such as walls, curbs and pipes,
Bonding Adhesive is not required when the flashing
b. For Polyisocyanurate less than 1 -1/2" thick or height is 12" or less and the membrane is terminated
Foamular or DOW Extruded Polystyrene, any under a metal counterflashing (nailed). When a coping
thickness, a minimum of 6 fasteners and plates per or termination bar is used for vertical terminations,
4' x 8' board are required. Bonding Adhesive may be eliminated for flashing
heights 18" or less.
Note: Extruded polystyrene insulation is for
use directly under white Sure -Weld E. Other Related Work
membrane only.
1. Walkways are required for all traffic concentration
c. Insulation boards 4' x 4', regardless of thickness, points (i.e., roof hatches, access doors, rooftop ladders,
must be fastened at the minimum rate of 1 fastener etc.), regardless of traffic frequency. Walkways are also
and plate every 4 square feet. required if regular maintenance (once a month or more)
is necessary to service rooftop equipment. Walkways
2. Carlisle Piranha Plates, Seam Fastening Plates (2" are considered a maintenance item and are excluded
diameter) or Insulation Fastening Plates (3" diameter) from the Carlisle Warranty.
must be used with appropriate Carlisle Fastener for
insulation attachment. 2. Sure-Weld Heat Weldable Walkway Rolls are required
when walkway pads are specified and are heat welded to
B. Membrane Placement, Attachment and Hot Air Welding the Sure -Weld Membrane.
1. A minimum of one perimeter sheet shall be installed at When concrete pavers are used, they shall be loose laid
edges of each roof level and 12', 10' or 8' wide and installed in conjunction with a slip sheet of
membrane shall be installed in the field of the roof. reinforced membrane or two layers of HP Protective
Mat. Concrete pavers are not recommended when the
2. Membrane sheets shall be mechanically fastened with roof slope is greater than 2" per 1 horizontal foot.
the appropriate Carlisle Fastener/Fastening Plate spaced
6" to 12" on center, depending on project criteria, within Carlisle Interlocking PaversT"', 24" X 24" X 2 ",
the membrane splice. Refer to the "Design Criteria" weighing approximately 6 pounds per square foot may
section for required number of perimeter membrane be loose laid directly over the membrane. Installation
sheets and fastener spacing. instruction sheets are available from Carlisle.
3. Overlap adjacent membrane sheets approximately 5-1/2"
3
600319 SWMF Guide - 212006
3. Copings, counterflashing and other metal work,
not supplied by Carlisle, shall be fastened to
prevent metal from pulling free or buckling and
sealed to prevent moisture from entering the
roofing system or building.
Attach copies of the applicable Carlisle Details that pertain to
the individual project to complete a bid package submittal.
Membrane Physical Properties
Property of Property
Property (Metric - Units) Test Method Unaged Sheet After Aging (1)
Tolerance on Nominal Thickness, % ASTM D 751 ±10 ±10
ASTM D 4637 0.015 (0.381) Min.
Thickness Over Scrim, min, in. (mm) Optical Method 0.018 (0.457) Typ.
Solar Reflectance (albedo X 100), % ASTM E 903 White - 80 Typ.
Gray - 25 Typ.
Breaking Strength, min, lbf (kN) ASTM D 751 225 (1.0) Min. 225 (1.0) Min
Grab Method 340 (1.5) Typ. 340 (1.5) Typ.
Elongation at Break of Fabric, min, % ASTM D 751 25 Typ. 25 Typ.
Tearing Strength, min, Ibf (l) 8" by 8" speciman ASTM D 751 55 (245) Min. 55 (245) Min.
B Tongue Tear 130 (578) Typ. 130 (578) Typ.
Brittleness Point, max, °F ( °C)
ASTM D 2137 -40 (-40) Min.
-50 (-46) Typ.
Linear Dimensional Change (shrinkage), % ASTM D 1204 +/- 1.0 Max,
-0.5 Typ.
Ozone Resistance*
Condition after exposure to 100 pphm ASTM D 1149 No Cracks No Cracks
Ozone in air for 168 hours Q 104 °F (40 °C)
Specimen wrapped around 3 in. mandrel
Resistance to Water Absorption* ASTM D 471 4.0 Max.
After 7 days immersion 158 °F (70 °C) Change in mass, max, % 2.0 Typ.
Resistance to microbial surface growth, rating (1 is very poor, 10 is no ASTM D 3274 9 - 10 Typ.
growth) 2 yr. S. Florida
Field seam strength, lbf/in. (kN /m) Seam tested in peel ASTM D1876 40 (7.0) Min.
60 (10.5) Typ.
ASTM E 96 0.10 Max.
Water vapor permeance, Penns 0.05 Typ.
Puncture resistance, lbf(N) FTM IOIC 250 (1110) Min. 250 (1110) Min.
Method 2031 300 (1330) Typ. 300 (1330) Typ.
Resistance to xenon -arc Weathering' ASTM G 26 No Cracks
Xenon -Arc, 5040 k1/m5 total radiant exposure 0.70 W /m5 No loss of breaking
visual condition at IOX 90 °C B.P.T. or tearing strength
(1) Aging conditions are 28 days at 240° F (116° C) equivalent to 400 days at 176° F (80° C) for breaking strength, elongation, tearing strength, linear
dimensional change, ozone and puncture resistance.
(2) Approximately equivalent to 8000 hours exposure at 158° F (70° C) black panel temperature. 12/98
Copyright 2006 Carlisle SynTec Incorporated
Carlisle, Sure-Weld, Interlocking Pavers are Trademarks of Carlisle SynTec Incorporated.
Foamular is a Trademark of UC Industries, Inc.
Carlisle SynTec Incorporated, P. O. Box 7000, Carlisle, PA 17013 -0295
Phone: 800- 479 -6832
http: / /www.carlisle- syntec.com
4
600319 SWMF Guide - 2/2006
ROOF COVERING MATERIALS (TEVT) ROOF COVERING MATERIALS (TEVT) 73 "+'r
,:!tip;,'
Roofing Systems (TGFU)- Continued Roofing Systems (TGFU)- Continued 11tV
"'
C) Elk "VersaShield Underlayment" or "VersaShield FB -2S ". combination, any thickness, cellular concrete, precast concrete with ! tF`
Membrane: Any LL Classified Carlisle EPDM membrane grouted joists or structural (poured -in- place) concrete '.'i I'
•'e
4 peck: C -15/32 Incline: 1 Membrane: "72 mil Sure -Weld EXTRA" or "80 mil Sure -Weld EXTRA" - 'I,
Insulation: Carlisle HP Recovery Board or any UL Classified wood 13. Deck: NC Incline: 1/2 .�-
fiberboard, 1 /2 in. thick min. Insulation: See: "Referenced Insulations", any combination, any thick -
• Membrane: Any UL Classified Carlisle EPDM membrane. ness. +
'Clans :A =� Mechanitally Fastened_(T -P�U) Membrane: '72 mil Sure -Weld EXTRA" or "80 mil Sure -Weld EXTRA ".
I. Deck: NC Incline: 1/2 14. Deck: NC Incline: 1/2 '
Insulation: See "Referenced Insulations ", any combination, any thick- Insulation: See: "Referenced Insulations ", any combination, any thick-
ness. ness. 1
Membrane: "Sure- Weld ". Membrane: "Sure -Weld FleeceBACK + 100 or 115" (TPO).
2. Deck: NC Incline: 1-1/2 15. Deck: NC Incline: 1-1/2 .
Insulation: Carlisle HP Recovery Board, 1/2 to 3 in.; Carlisle Recovery Insulation (Optional): Any UL Classified, any thickness. ,ax
Board, 1 /2 in. min, over any Classified insulation, any combination, any Insulation: 1/2 in. thick "HP Recovery Board ". . t •
thickness; cellular concrete, precast concrete with grouted joints or
Membrane: "Sure -Weld FleeceBACKOO 100 or 115" (TPO).
structural (poured -in- place) concrete. 16. Deck: NC Incline: 3
Membrane: "Sure- Weld ".
Insulation: Any UL Classified, any thickness.
3. Deck: NC Incline: 1 -1/2 Barrier Board: 1/4 in. G P Gypsum Dens DeckO or 1/2 in. gypsum 3
Insulation: See "Referenced Insulations ", any combination, anv thick- wallboard
Membrane: "Sure -Weld FleeceBACK < 100 or 115" (TPO).
Hess. 17. Deck: C -13/32 Incline: See Note ,
Membrane: "Sure -Weld HS" or "Sure -Weld GSD ".
•
4. Deck: NC Incline: 1-1/2 Slip Sheet: Two layers Carlisle 'TR Base Sheet ", Elk " VersaShield
Insulation: Carlisle HP Recovenv Board, 1/2 to 3 in.; Carlisle Recovery Underlayment" or "VersaShield FB-2S".
Board, 1/2 in. min, over any Classified insulation, any combination, any Insulation (Optional): Any UL Classified (except EPS ), any combina-
thickness; cellular concrete, precast concrete with grouted joints or tion, any thickness.
structural (poured -in- place) concrete. Membrane: Any UL Classified Carlisle TPO membrane.
Membrane: "Sure -Weld HS" or "Sure -Weld GSD ".
Note: Max incline shall be in accordance with Classification estab- �'
5. Deck: NC Incline: 3 lished for the insulation /membrane roofing system, but can not
4
Insulation (Optional): Any LL Classified, any combination, any thick- exceed 2:12.
Hess. Class B • Mechanically Fastened (T P 0)
Barrier Board: 1/2 in. thick gypsum wallboard or 1 /4 in. thick G -P 1 Deck: C-15/32 Incline: See Not
Base Sheet: One laver, mechanically fastened, of one the following:
Gypsum Dens-Deck® A.) Owens Corning "Perma Ply No. 28" . g +f.
Membrane: "Sure held ". B.) GAF "Gafglas # 75 Base Sheet" .
6. Deck: C -15/32 Incline: See Note C.) Johns Manville "Glasbase" .
Slip Sheet: Two lavers Carlisle "FR Base Sheet ", Elk " VersaShield a) Tamko "Glass Base" .
Underlayment" or "VersaShield FB -2S ".. E.) Celotex Type G2 "Vaporbar GB" .
Insulation: Any UL Classified (except EPS), any combination, any F. Carlisle "FR Base Sheet ". :.,�
thickness.. G Elk "VersaShield Underlayment" or "VersaShield FB -2S ". • J
Membrane: Any LL Classified Carlisle TPO membrane. Insulation: See "Referenced Insulations ", min 1 -1/2 in. thickness;
Note: Max incline shall be in accordance with Classification estab- Carlisle HP Recovery Board or UL Classified wood fiber board, min 1 in.
lished for the insulation /membrane roofing system, but can not thick; Carlisle HP Recover Board or UL Classified wood fiber board, r
� exceed 2:12. min 1/2 in. thick over any Classified insulation (any combination), min
Deck: C -15/32 Incline: Unlimited 1 in. thick. The bottom insulation laver joints are to be staggered a min 6
Insulation (Optional): Any UL Classified, any combination, any in. from the deck joints. "''
thickness. Membrane: Any IA Classified Carlisle membrane.
Barrier Board: 1/2 in. min gypsum hoard or 1/4 in. thick G -P Gypsum Note: Max incline shall be in accordance with Classification estab- ` "` •
Dens -Deck® with staggered joints (6 in. offset). lished for the insulation /membrane roofing system but not to exceed .• ;
Membrane: "Sure -Weld HS" or "Sure -Weld GSD ". 1 in. 7. t
8. Deleted 2. Deck: C -15/32 Incline: See Note
9. Deck: C -15/32 Incline: See Note Insulation: Carlisle HP !'' c
Recovery Board or UL Classified wood fiber �c
Slip Sheet: One layer ,Atlas Roofing "FR -10" or "FR -50 ", Carlisle "FR board, min 1 -1/2 in. thick. The bottom insulation laver joints are to be
Base Sheet" or Elk "VersaShield Underlayment" or "VersaShield FB -2S ". staggered a min 6 in. from the deck joints. •`
Insulation: Atlas Roofing "ACFoam III ", 1.5 in. thick with joints Membrane: Any UL Classified Carlisle membrane.
staggered min 6 in. from the deck joints. Note: Max incline shall be in accordance with Classification estab-
Membrane: Any UL Classified Carlisle membrane. lished for the insulation /membrane roofing system but not to exceed e ,
Note: Max incline shall be in accordance with Classification established 1 in.
•
for the insulation /membrane rcx+fin system. Incline: 1 /2 g b 3. Deck: C-15/32 Incline: See Note
10. Deck: C -15/32 Slip Sheet: One layer Carlisle "FR Base Sheet" or Elk "VersaShield !
Slip Sheet: Two plies Atlas Roofing "FR -50 ". Underlayment" or VersaShield FB -2S ". . `
Membrane: Any UL Classified Carlisle membrane. Membrane: Any UL Classified Carlisle TPO membrane.
IOA.Deck: C -15/32 Incline: See Note Note: Max incline shall be in accordance with Classification estab- 1. •. •
„p;t
Slip Sheet: Two lavers Carlisle "FR Base Sheet" or Elk "VersaShield lished for the membrane roofing system, but can not exceed 1- 1/2:12. . r`'
Underlayment" or VersaShield F13-25". 4. Deck: C -15/32 Incline: 1/2 :._
Membrane: Anv UL Classified Carlisle TPO membrane. Insulation (Optional): Polvisocyanurate, min 1 in. thickness. ,
Note: Max incline shall he in accordance with Classification established Slip Sheet Two layers .atlas Roofing "FR 50 ", Carlisle "FR Base Sheet"
for the membrane roofing system, but can not exceed 1-1/2:12. or Elk "VersaShield Underlayment" or "VersaShield FB -2S. v
11. Deck: C -15/32 Incline: 2-1/2 Membrane: Any UL Classified Carlisle TPO membrane.
Insulation (Optional): Any UL Classified, any combination, any 5. Deck: C -15/32 Incline: 1/2
thickness. P ply Roofing Sli Sheet: One I Atlas Rcxrfin FR 50 ".1
Barrier Board: 1/2 in. min gypsum hoard. Membrane: "Sure -Weld HS" or "Sure -Weld GSD ". 1.
Membrane: '72 mil Sun -Weld EXTRA" or "80 mil Sure -Weld EXTRA" Class C - Mechanically Fastened IT P 0) ., ,
12 - Deck: NC Incline: 1 -1/2 1. Deck: C -15/32 Incline: 1 `-
Insulation: Carlisle HP Recovery Board, 1/2 in. to 3 in., Carlisle Base Sheet: One layer, mechanically fastened, of one of the following: }'`
Recover Board, l,'' i 'ti
_ in. min, user any Classification insulation, any A.) Johns Manville "Perna Ply Nu. 28 ". r,
fir
i t
LOOK FOR THE UL MARK ON PRODUCT
�'t j Y __ - 1 31; �? ,,, lRt qr w ' . x#' ' ; ?p !l )- S.K,�
\1 1.at. ° I�i of Fyn ili v)---... I �N
i. 4 \.`4,,.% t. 1 j .y 0 . 1 f , . :.N Y V 1 C - " � , �4' ,T f .,, ..✓
_� n 0 Y'
` b 1
� ` ,7,,,-..,1,‘m , ;41 -' �. `� �t y . ° _, ��,
,�V `i try ( � • L\ itai„
, ,, c �, �i ;mo ;o ., �' :�� .�
, =J ' `�' r "".. _ __ r . 7 a 1 , - % .hy ti !t
r s ' � •i � ''' Wrd ' •
i �j a ` -� - i t �4 'F ' 17 •!" .t. }c ti. .- e- .._....c.... r.r..... « ,,` CS °.- tr..w r ,
6`' \ (i , h \ 3 ; s S. I� 7, a p 1 3 ' t p '.'." -1 1 `� •
cam. -:
A. ;�"`." 'r �� � � �.' s T � . •J �t , � .�- t _' ' 7 v. �c � ti q• i r` \t\ \ . '� . � .r 4 / •• °.• ` ! -. +": : t.g , `t- �' ' ;.'., . t (�] '•i 1e.�S(taU- i ti ''� N t ` 4 ,� ° Bank of America' ' ? s 1 ./ ,".'—. """ , )
o L 'P z't s
\ i G� ,1 N1t,Y 7.4..,n1104-,..= i .,►_ :tPQZ « .. >. 4, ; !c r G t r .. n ' e i _ •n 3 : 1
i. ti �i ° ▪ ``r • �. shingto. L4.7 `� • d ". e g 1 1 0y `
trVI
I - ''' \ ' ; . . f4 . :7 0 r ? ':.• C. ' I ; 'I- tr" 4 1 ' ''. ' 1F - . ' "' . \7 ' l i r. ,iti;,,,Y.i t t i "* . ." -...,:- , . . .,4 4' 1 4) 1
^t
N
d i 1 - . U.1, \ ''.'-`4a ''' ..-.. ,•rr ' • 2.• • 'I I .'' , ■ (i: • ... 17 lkirk .
. I A 4 , - , '� _• _. t. • �' , a . 1 s a ''r
d •• i A Sa ,. �ti � �� 41� 1.0 . t b t/ •` ( � l ip.
A' ' • . ,, ' -- - ' , ?4 - -,., - ..4 :12).,,,,,,, ..-t•-, ..;''i/ 1 • • 4 i ''.'. i.,..,• ••,•• ''' Li ...... • ,
4.-7i
— a y " / fill i r 1 I i \ ' // r t tT!.n. ; /' s- , • {e • ti t i.
\'a �.
JO i - ; 1�_ �,; t ° �.; P. �c� i� S
outhwest Oa •
� �• ' t ~ ` � . � t -. ��# ; ,. *2008 TeleAtlast q. \� ...„..s,,,,
a . t 1
a u Image ® 2008 Melw,`Pmtland O=;-pon lll,,�X ' C � ` . )` 44L,, F. -
. l' 1886I
. m � ' ; . j • .
, ),(�1.,,N �
14 -S - T * •
t1 .. . S , � R ` - 1
• N.'� 0�
L _. _._._� T " . "T . ' f -4 i� - .. , ‘ - _ :RSA:
,
+
' o
- - ■ r
r.
g
O■ I.,. - .
E3 #11
ri 1.1
q .
Sure- We1dTM (TP0) Mechanically- Fastened Roofing System
Underwriters Laboratories Approvals
Membrane Type: .045" or .060" Sure -Weld Standard Reinforced Membrane (White, Gray or Tan)
.045" or .060" Sure -Weld HS Reinforced Membrane (White, Gray or Tan)
.072" or .080" Sure -Weld EXTRA Reinforced Membrane (White, Gray or Tan)
UL Class "A"
Maximum Slope
Sure -Weld Sure -Weld
Deck Type Insulation (1) Thickness Standard or HS
EXTRA
Carlisle Polyisocyanurate HP -H, HP -DWD Any
Non - Combustible Hunter Panels H- Shield. H- Shield -DWD 1/2" 1 -1/2
and Combustible Carlisle HP Recovery Board 1/2" - 3"
(For combustible Carlisle HP Recovery Board/Polyisocyanurate 1/2" Min /Any 1 -1/2" 1 -1/2"
decks, gypsum board Carlisle HP Recovery Board/Polystyrene (5) 1/2" Min /Any
must be installed Carlisle FR Base Sheet 2S over Thermapmk 18 or
beneath the 25 (5X7) Base Sheet/Any 1" 1"
insulations listed) Carlisle FR Base Sheet 2S over DOW Styrofoam
(2)(3X4) (5X7) Base Sheet/Any N/A 1"
Combustible (6) Gypsum Board 1/2" (2X4) 3" Standard
Gypsum Board/Polyisocyanurate 1/2" /Any (2X4) 2-1/2" EXTRA Unlimited
Gypsum Board/Polystyrene I/2" /Any (2X4)
Carlisle Polyisocyanurate HP -DWD (4) 3" Min.
1/2" 1 -1/2"
Hunter Panels H- Shield -DWD (4)
Polyisocyanurate listed above over 2 layers of
Any/2 layers 1/2" 1 -1/2"
Carlisle FR Base Sheet 2S
Two layers Carlisle FR Base Sheet 2S
Two layers Carlisle FR Base Sheet 2S over Two layers of
1/2" 1/2"
minimum Class C Smooth BUR, mineral cap Base Sheet
sheet or Modified Bitumen
Carlisle FR Base Sheet 2S- 3 layers (Polyiso 3 layers
optional over base sheets) (optional Polyiso N/A Unlimited
— Anv) _
Approved 3" Standard
Lightweight Direct Application N/A 2 -I/2" EXTRA Unlimited
Insulating Concrete
Notes:
(1) When multiple insulation layers are listed (i.e., HP Recovery Board/Polyisocyanurate), the insulation listed first (HP Recovery Board) is
directly under the membrane.
(2) Minimum 1/2" thick gypsum board can be a classified or unclassified material with a minimum weight of 1.84 pounds per square foot.
1/4" thick Carlisle /Georgia Pacific Dens -Deck or Georgia Pacific Sound Deadening Board with a minimum weight of L09 pounds per
square foot may be substituted for 1/2" thick gypsum board.
(3) On Retrofit/No Tearoff projects, where the existing roof is Class A rated, gypsum board may be eliminated. Existing Class B or C rated
roofs will require use of gypsum board to achieve a Class A rating, otherwise, the new roofing system will retain existing UL rating.
(4) Insulation joints (bottom layer) are to be staggered a minimum of 6" from joints in wood deck.
(5) Assembly not permitted on combustible decks, even with gypsum board underneath. Gypsum board must be installed over polystyrene as
identified in combustible deck listing.
(6) Combustible deck ratings can be used on non - combustible decks.
(7) Assembly acceptable for white Sure -Weld membrane only.
600163 SW Codes 1 1/2007
,_ - ' J S '' ' - � CARLISLE'S
z % ' t �.
{� M wr YY
r'q1 Iii ?F ; : v¢ ., . l ® 1 - ')r)- , Y �a[a ' _ ...1.1 } IIte'
N,T,P,i0
GUIDE -SPEC
Sure -Weld® TPO MECHANICALLY- FASTENED ROOFING SYSTEM
February 2006
This GUIDE -SPEC is a brief outline of Carlisle's Sure- 3. Projects with fasteners specified to exceed 12 ".
Weld Mechanically- Fastened Roofing System requirements and is
intended for use as a submittal with a bid package. Specifiers and 4. Air pressurized buildings, canopies and buildings with
the Carlisle Authorized Roofing Applicator must comply with the large openings where the total wall opening exceeds
"Design Criteria" and "Application" sections of Carlisle's 10% of the total wall area where openings are located.
Specifications prior to design or bid.
5. Cold storage buildings and freezer facilities.
PART I GENERAL
1.01 DESCRIPTION 6. Projects where the membrane is expected to come in
direct contact with petroleum -based products or other
The Sure-Weld Mechanically - Fastened Roofing System chemicals.
incorporates 12', 10' or 8' wide, white, gray or tan 45, 60, 72 or 80-
mil thick scrim- reinforced Sure -Weld Thermoplastic Polyolefm B. Along with the project submittals (shop drawings and
(TPO) membrane. Insulation is mechanically fastened to an Request for Warranty), the roofing contractor must include
acceptable roof deck. Sure-Weld perimeter sheets (6', 5' or 4' wide pullout tests when:
respectively) are installed along the building edges and field
membrane sheets are mechanically fastened to the roof deck with 1. HP -X Fasteners are used through a lightweight
the appropriate Carlisle Fasteners and Fastening Plates. Adjoining insulating concrete substrate into a steel deck lighter
sheets of Sure-Weld membrane are overlapped and joined together than 22 gauge.
with a minimum 1 -1/2" wide hot air weld. Refer to the "Design
Criteria" section for the required number of perimeter membrane 2. HP -X Fasteners are used in conjunction with plywood
sheets and the required fastener spacing. decks less than 5/8" thick or oriented strand board
(OSB) minimum 7/16" thick.
1.02 QUALITY ASSURANCE
4. HP -NTB Fasteners are used in conjunction with
A. This roofing system must be installed by a Carlisle cementitious wood fiber and gypsum decks.
Authorized Roofing Applicator in compliance with shop
drawings as approved by Carlisle. There must be no C. For all projects (prior to project inspection by Carlisle) a final
deviations made without the PRIOR WRITTEN shop drawing must be approved by Carlisle.
APPROVAL of Carlisle.
1.04 PRODUCT DELIVERY, STORAGE AND
B. Upon completion of the installation, an inspection will be HANDLING
conducted by a Field Service Representative of Carlisle to
ascertain that the membrane roofing system has been installed A. Deliver materials to the job site in the original, unopened
according to Carlisle's published specifications and details containers labeled with the manufacturer's name, brand name
applicable at the time of bid. and installation instructions.
C. This roofing system meets Underwriters Laboratories (UL) B. Store Sure-Weld membrane in the original undisturbed plastic
and Factory Mutual (FM) requirements. For specific code wrap.
approvals achieved with this roofing system, refer to the
Sure-Weld Code Approval Guide, Factory Mutual Approval C. Job site storage temperatures in excess of 90° F may affect
Guide or Underwriters Fire Resistance and Roofing Materials shelf life of curable materials (i.e., adhesives and sealants).
and Systems Directories.
D. When liquid adhesives and sealants are exposed to lower
1.03 SUBMITTALS temperatures, restore to a minimum of 60° Fahrenheit before
use.
A. To ensure compliance with Carlisle's warranty requirements,
the following projects should be forwarded to Carlisle for E. Do not store adhesive containers with opened lids due to the
review prior to installation, preferably prior to bid. loss of solvent, which will occur from flash off.
1. Projects where a wind speed warranty coverage greater F. Insulation and underlay- ?1. r = e�
• than 55 MPH peak gusts is specified went must be stored so it is `- I. L I , S L -
kept dry and is protected et a : "-' ' '` '• o '"'
2. Projects where the building height exceeds 50'. from the elements. Store Carlisle SynTec Incorporated
1
600319 SWMF Guide - 2/2006
insulation on a skid and completely cover with a breathable
material such as tarp or canvas. If the insulation is 2.02 MEMBRANE
lightweight, it should be weighted to prevent possible wind
damage. Sure-Weld white, gray or tan 45, 60, 72, 80 -mil thick reinforced
Thermoplastic Polyolefin (TPO) membrane is used for this system.
1.05 JOB CONDITIONS Field membrane sheets are 12', 10' or 8' wide by 100' long based
on project conditions. Perimeter sheets are 6' wide (used with 12'
A. This system must not be applied on projects where the slope field sheets), 5' wide (used with 10' field sheets) or 4' wide (used
exceeds 18" in one horizontal foot. When the roof slope with 8' field sheets). For physical properties of membrane, refer to
exceeds 5" per horizontal foot, use of an automatic welding page 4.
machine may be more difficult. A hand held welder should
be specified. 2.03 RELATED MATERIALS
B. Existing roofing material must be investigated by the Sure -Weld Non - Reinforced or Reinforced Flashing, Bonding
specifier and all wet material must be removed. Adhesive, Cut Edge Sealant, Water Cut -Off Mastic, PT 304
Sealant, EP -95 Spicing Cement, Weathered Membrane Cleaner,
C. Existing phenolic insulation and sprayed -in -place urethane Molded Pocket Sealant, Heat Weldable Walkway Pads, Pre -
roofs must be removed prior to installation of this system. Molded Inside /Outside Corners, Pipe Flashings, Curb Wraps and
Sealant Pockets.
D. The use of a vapor retarder to protect insulation and reduce
moisture accumulation within an insulated assembly should PART ID EXECUTION
be investigated by the specifier. Consult the publications by 3.01 GENERAL
ASHRAE (American Society of Heating, Refrigerating and
Air - Conditioning Engineers, Inc.) and NRCA (National A. When feasible, begin the application at the highest point of
Roofing Contractors Association) for specific information. the highest roof level and work to the lowest point to prevent
moisture infiltration and to minimize construction traffic on
E. Coordination between trades is essential to avoid unnecessary completed sections. This will include completion of all
traffic over sections of the roof and to prevent damage to the flashings, terminations and daily seals.
membrane roofing system.
B. Follow criteria outlined in the "Design Criteria" section to
1.06 WARRANTY prepare the roof deck or the existing substrate prior to the
application of the new roofing system.
All warranties are available for commercial projects only.
3.02 ROOF DECK CRITERIA
A. A 5 or 10 year Membrane System Warranty, with a wind
speed coverage of up to 55 mph is available for a charge. A. Proper substrate shall be provided by the building owner.
The structure shall be sufficient to withstand normal
B. A 10 or 15 -year Total Roofing System Warranty is construction loads and live loads.
available for a charge on commercial projects. Projects will
receive a maximum peak gust wind speed coverage up to 55 B. Defects in the roof deck must be reported and documented to
mph unless prior review is performed by Carlisle regarding the specifier, general contractor and building owner for
an extended wind speed coverage. assessment. The Carlisle Authorized Applicator shall not
proceed with installation unless defects are corrected.
The 15 -year Warranty is not available for projects with
cementitious wood fiber or gypsum decks. C. Acceptable decks and the applicable Carlisle Fasteners:
Note: Due to various wind uplift coverages available, 1. Steel, 22 gauge or heavier - Carlisle HP -X
these projects must be reviewed by Carlisle prior to Fasteners/Piranha Plates or HP -Xtra Fasteners/Piranha
bid, preferrably in design phase, to determine Xtra Plates are required with a minimum pullout of 500
system enhancements that may be applicable. pounds per fastener.
C. A 20 -year Total System Warranty is available for a charge 2. Lightweight Insulating Concrete over steel - Carlisle
for projects utilizing minimum 60 -mil thick Sure -Weld HP -X Fasteners/Piranha Plates are required with a
membrane and incorporating additional design minimum pullout of 360 pounds per fastener (into steel
enhancements as outlined in "Attachment IV", 20 -Year deck below the lightweight concrete).
Warranty Design Enhancements, in the Sure-Weld Design
Criteria Specification. 3. Structural Concrete, rated 3,000 psi or greater —
Carlisle CD-10 or HD 14 -10 Fasteners (with Piranha
PART II PRODUCTS Plates) are required with a minimum pullout of 800
2.01 GENERAL pounds per fastener.
The components of this roofing system are to be products of 4. Wood Plank, minimum 15/32 thick Plywood - Carlisle
Carlisle or accepted by Carlisle as compatible. The installation, HP -X Fasteners/Piranha Plates are required
performance or integrity of products by others, when selected by
the specifier and accepted by Carlisle, is not the responsibility 5. On oriented strand board (OSB) decks, HP -X Fasteners
of Carlisle and is expressly disclaimed by the Carlisle Warranty. and Pirahna Plates may be used providing a pullout of
2
600319 SWMF Guide - 2/2006
•
360 pounds can be obtained Please contact Carlisle's at those locations where Fastening Plates are located
Systems Design and Review Group sheet sizing and (along length of the membrane) and a minimum of 2" at
fastener spacing. end roll sections (width of the membrane).
6. Cementitious Wood Fiber and Gypsum - The Carlisle 4. Hot air weld the membrane sheets a minimum of 1 -1/2"
HP -NTB Fastener is required with a minimum pullout with an Automatic Hot Air Welding Machine.
of 300 pounds.
5. Membrane that has been exposed to the elements for
3.03 SUBSTRATE PREPARATION approximately 7 days must be prepared with Weathered
Membrane Cleaner. Wipe the surface where Weathered
A. On retrofit - recover projects, cut and remove wet insulation, Membrane Cleaner has been applied with a clean, dry
as identified by specifier, and fill all voids with new HP Splice Wipe or other white rag to remove cleaner
insulation so it is relatively flush with existing surface. residue prior to hot air welding.
B. For all projects, substrate must be even without noticeable C. Additional Membrane Securement
high spots or depressions, and must be free of accumulated
water, ice or snow. The membrane must be secured at the perimeter of each roof
level, roof section, expansion joint, curb, skylight, interior
C. Clear the substrate of debris and foreign material. Fresh wall, penthouse, etc., at any angle change which exceeds 2"
bitumen based roof cement must be removed or concealed in one horizontal foot and at all other penetrations in
accordance with Carlisle's Details published with Carlisle's
3.04 INSTALLATION Specifications.
Refer to the applicable Material Safety Data Sheets and Technical D. Membrane Flashing
Data Bulletins for applicable cautions and warnings.
1. Flash all walls and curbs with Sure -Weld reinforced
A. Insulation Attachment membrane. Non - Reinforced membrane shall be limited
to inside and outside corners, field fabricated pipe seals,
1. Carlisle Insulation shall be mechanically fastened to the scuppers and Sealant Pockets where the use of pre-
roof deck as follows: molded accessories are not practical. Terminate the
flashing in accordance with an appropriate Carlisle SW-
a. For HP Recovery Board or minimum 1 -1/2" thick 9 Termination Detail.
Polyisocyanurate, a minimum of 5 fasteners and
plates per 4' x 8' board are required. 2. On vertical surfaces, such as walls, curbs and pipes,
Bonding Adhesive is not required when the flashing
b. For Polyisocyanurate less than 1 -1/2" thick or height is 12" or less and the membrane is terminated
Foamular or DOW Extruded Polystyrene, any under a metal counterflashing (nailed). When a coping
thickness, a minimum of 6 fasteners and plates per or termination bar is used for vertical terminations,
4' x 8' board are required. Bonding Adhesive may be eliminated for flashing
heights 18" or less.
Note: Extruded polystyrene insulation is for
use directly under white Sure-Weld E. Other Related Work
membrane only.
1. Walkways are required for all traffic concentration
c. Insulation boards 4' x 4', regardless of thickness, points (i.e., roof hatches, access doors, rooftop ladders,
must be fastened at the minimum rate of 1 fastener etc.), regardless of traffic frequency. Walkways are also
and plate every 4 square feet. required if regular maintenance (once a month or more)
is necessary to service rooftop equipment. Walkways
2. Carlisle Piranha Plates, Seam Fastening Plates (2" are considered a maintenance item and are excluded
diameter) or Insulation Fastening Plates (3" diameter) from the Carlisle Warranty.
must be used with appropriate Carlisle Fastener for
insulation attachment. 2. Sure-Weld Heat Weldable Walkway Rolls are required
when walkway pads are specified and are heat welded to
B. Membrane Placement, Attachment and Hot Air Welding the Sure -Weld Membrane.
1. A minimum of one perimeter sheet shall be installed at When concrete pavers are used, they shall be loose laid
edges of each roof level and 12', 10' or 8' wide and installed in conjunction with a slip sheet of
membrane shall be installed in the field of the roof. reinforced membrane or two layers of HP Protective
Mat. Concrete pavers are not recommended when the
2. Membrane sheets shall be mechanically fastened with roof slope is greater than 2" per 1 horizontal foot.
the appropriate Carlisle Fastener/Fastening Plate spaced
6" to 12" on center, depending on project criteria, within Carlisle Interlocking PaversT'", 24" X 24" X 2 ",
the membrane splice. Refer to the "Design Criteria" weighing approximately 6 pounds per square foot may
section for required number of perimeter membrane be loose laid directly over the membrane. Installation
sheets and fastener spacing. instruction sheets are available from Carlisle.
3. Overlap adjacent membrane sheets approximately 5-1/2"
3
600319 SWMF Guide - 2/2006
3. Copings, counterflashing and other metal work,
not supplied by Carlisle, shall be fastened to
prevent metal from pulling free or buckling and
sealed to prevent moisture from entering the
roofing system or building.
Attach copies of the applicable Carlisle Details that pertain to
the individual project to complete a bid package submittal.
Membrane Physical Properties
Property of Property
Property (Metric -SI Units) Test Method Unaged Sheet After Aging (1)
Tolerance on Nominal Thickness, % ASTM D 751 ±10 ±10
Thickness Over Scrim, min, in. (mm) ASTM D 4637 0.015 (0.381) Min.
Optical Method 0.018 (0.457) Typ.
Solar Reflectance (albedo X 100), % ASTM E 903 White - 80 Typ.
Gray - 25 Typ.
Breaking Strength, min, Ibf (kN) ASTM D 751 225 (1.0) Min. 225 (1.0) Min
Grab Method 340 (1.5) Typ. 340 (1.5) Tvp.
Elongation at Break of Fabric, min, % ASTM D 751 25 Typ. 25 Typ.
Tearing Strength, min, lbf(N) 8" by 8" speciman ASTM D 751 55 (245) Min. 55 (245) Min.
B Tongue Tear 130 (578) Typ. 130 (578) Typ.
ASTM D 2137 -40 (-40) Min.
Brittleness Point, max, °F ( °C)
-50 (-46) Typ.
Linear Dimensional Change (shrinkage), % ASTM D 1204 +/_ 1.0 Max.
-0.5 Typ.
Ozone Resistance*
•
Condition after exposure to 100 pphm ASTM D 1149 No Cracks No Cracks
Ozone in air for 168 hours @ I04 °F (40 °C)
Specimen wrapped around 3 in. mandrel
Resistance to Water Absorption* ASTM D 471 4.0 Max.
After 7 days immersion A 158 °F (70 °C) Change in mass, max, % 2.0 Typ.
Resistance to microbial surface growth, rating (1 is very poor, 10 is no ASTM D 3274 9 - 10 Typ.
growth) 2 yr. S. Florida
ASTM D1876 40 (7.0) Min.
Field seam strength, lbf/in. (kN /m) Seam tested in peel 60 (10.5) Typ.
ASTM E 96 0.10 Max.
Water vapor permeance, Perms 0.05 Typ.
FTM 101C 250 (1110) Min. 250 (1110) Min.
Puncture resistance, lbf (N) Method 2031 300 (1330) Typ. 300 (1330) Typ.
Resistance to xenon -arc Weathering ASTM G 26 No Cracks
Xenon -Arc, 5040 kJ /m5 total radiant exposure 0.70 W /m5 No loss of breaking
visual condition at 1OX 90 °C B.P.T. or tearing strength
(1) Aging conditions are 28 days at 240° F (116° C) equivalent to 400 days at 176° F (80° C) for breaking strength, elongation, tearing strength, linear
dimensional change, ozone and puncture resistance.
(2) Approximately equivalent to 8000 hours exposure at 158° F (70° C) black panel temperature. 12/98
Copyright 2006 Carlisle SynTec Incorporated
Carlisle, Sure -Weld, Interlocking Pavers are Trademarks of Carlisle SynTec Incorporated.
Foamular is a Trademark of UC Industries, Inc.
Carlisle SynTec Incorporated, P. O. Box 7000, Carlisle, PA 17013 -0295
Phone: 800 - 479 -6832
http: / /www.carlisle- syntec.com
4
600319 SWMF Guide - 2/2006
•
. c
•
r ' = ' . _.
it,.. ' '' fi litt, . '. s' ' ; ' 1. : 0 . i
r
,4,._ , ::•„_,- 0., . . . . ,...
, .. 2. :t . .
•
. . .
. : , . •:_ ...,...
. •
..
,,. ,••....,*4.....1„,
_.... _. , , _7,1 . ,
y a
44,7 :
iiim
•
\!•2:2: f - - .5 :1 Xf ? •
ray ii. ▪ , ,. .S 0 1 •. i
- , 1 - - --1; ,1 ,,, ,,..
\# l �,. V � � � . • __' y ' • � V , � _ r ... i fi :'
„ r
�^� `7 t •�\ .y ' , ` '� I3 � , Cr 4• 9 F� 1 � � r • l►•''r ti s-+'�- ..".,...•�_ ...y..:; ---s: � - � .. . *i •
y_ y w 1. t o ,, r t r , ' y 1 '� • pP� '� • -. 1 I 41' ' : :
i . ' t 9 _ 1' • '] S i .. i \ \ ` t c � 4, , T y! "• j `'* a ` 1 r� ? - -L� ±• ^T. + .+ . a ' s . y ' 3r•iSi• rJs ' •
fr p ' 5 N o < i ' .. Bank'off Ameri ca' •* '' 1 ?� f j' • � 1 . —
`•f±_tv. - � ` • 1 � �'.. / tf .Its ' , Wei .. rf � 4 � 9 0 , � •, 9 ,1 ' , `w - s v,
.... , ' , � ' � a . r; - . l 4. I , ; .
l O Y 1 C ur �
� �= l:hi
t, \ \ -• \ • "{.4J ♦ n; ' ... ef ` " . All' ` • X-r N ^ ` ,.'._, f - ■ ., : .,
A \ \ +6 . ` ,. 1 1 ,, i .. 1 4 ` • , R s " , i ii .,'. .� '
; 4 I • ,r , ' . „ * + . 1. J! k.. �t. .�
It
�. . . ��� , + 1 j � + � , . l ,' • � r I X11.._ �!!• t I
1r
't illy 1 ' ,/ •' ` j I r , , '" \ �\ 4 4` � ` � r I. "•:4,147 4 ' f • Y w 1 ' .1 • 6' '
dI i , , --.,.. � ' ',, 01 1 ' „ ti L • ! ' s ” + 1 '•! r "v •
lot
I .1 / � ` c ' " (� mac 3 - r' i stO T
. s , 41, ri ' Pr 71 � ---- • ` 'o , e • � '' , ' 1' f ,,, „. r f •�
_ 1 a
1
. ar S .11 f , _:Yf ., 2008 TeleiAtlas N 1 \ r L ..O 1 .
]7'� , 4 1 � Image ®2008 Metro, Portla Ore gon ' 4'10 ..��• 1
l 1 -. 1:8'm . u ��U�la1�}� h. . -!' 1�.. l L' , . c O l 111
Sure- We1dTM (TPO) Mechanically- Fastened Roofing System
Underwriters Laboratories Approvals
Membrane Type: .045" or .060" Sure -Weld Standard Reinforced Membrane (White, Gray or Tan)
.045" or .060" Sure -Weld HS Reinforced Membrane (White, Gray or Tan)
.072" or .080" Sure -Weld EXTRA Reinforced Membrane (White, Gray or Tan)
UL Class "A"
Maximum Slope
Deck Type Insulation (1) Thickness Sure -Weld Sure -Weld
Standard or HS
EXTRA
Carlisle Polyisocyanurate HP -H, HP -DWD Any
Non - Combustible Hunter Panels H- Shield. H- Shield -DWD 1/2" 1 -1/2"
and Combustible Carlisle HP Recovery Board 1/2" - 3"
(For combustible Carlisle HP Recovery Board/Polyisocyanurate 1/2" MinJAny 1 -1/2" 1 -1/2"
decks, gypsum board Carlisle HP Recovery Board/Polystyrene (5) 1/2" MinJAny
must be installed Carlisle FR Base Sheet 2S over Thermapmk 18 or
beneath the 25 (5X7) Base Sheet/Any 1" 1"
insulations listed) Carlisle FR Base Sheet 2S over DOW Styrofoam
(2)(3X4) (5X7) Base Sheet/Any N/A 1"
Combustible (6) Gypsum Board 1/2" (2X4) 3" Standard
Gypsum Board/Polyisocyanurate 1/2" /Any (2X4) 2 -1/2" EXTRA Unlimited
Gypsum Board/Polystyrene 1/2" /Any (2X4)
Carlisle Polyisocyanurate HP -DWD (4) 3" Min. 1/2" 1 -1/2"
Hunter Panels H- Shield -DWD (4)
Polyisocyanurate listed above over 2 layers of Any/2 layers 1/2" 1 -1/2"
Carlisle FR Base Sheet 2S
Two layers Carlisle FR Base Sheet 2S
Two layers Carlisle FR Base Sheet 2S over Two layers of 1/2" 1/2"
minimum Class C Smooth BUR, mineral cap Base Sheet
sheet or Modified Bitumen
Carlisle FR Base Sheet 2S- 3 layers (Polyiso 3 layers
optional over base sheets) (optional Polyiso N/A Unlimited
— Any)
Approved
Lightweight Direct Application N 3" Standard Unlimited
Insulating Concrete 2-1/2" EXTRA
Notes:
(1) When multiple insulation layers are listed (i.e., HP Recovery Board/Polyisocyanurate), the insulation listed first (HP Recovery Board) is
directly under the membrane.
(2) Minimum 1/2" thick gypsum board can be a classified or unclassified material with a minimum weight of 1.84 pounds per square foot.
1/4" thick Carlisle /Georgia Pacific Dens -Deck or Georgia Pacific Sound Deadening Board with a minimum weight of 1.09 pounds per
square foot may be substituted for 1/2" thick gypsum board.
(3) On Retrofit/No Tearoff projects, where the existing roof is Class A rated, gypsum board may be eliminated. Existing Class B or C rated
roofs will require use of gypsum board to achieve a Class A rating, otherwise, the new roofing system will retain existing UL rating.
(4) Insulation joints (bottom layer) are to be staggered a minimum of 6" from joints in wood deck.
(5) Assembly not permitted on combustible decks, even with gypsum board underneath. Gypsum board must be installed over polystyrene as
identified in combustible deck listing.
(6) Combustible deck ratings can be used on non - combustible decks.
(7) Assembly acceptable for white Sure -Weld membrane only.
600163 SW Codes 1 1/2007
...I A ;.
3; v
ROOF COVERING MATERIALS (TEVT) ROOF COVERING MATERIALS (TEVT) 73 i; i
'. -,
Roofing Systems (TGFU)- Contfntted Roofing Systems (TGFU)- Contin 'j.• .,
G) Elk "VersaShield Lnderlayment" or "VersaShield FB-2S". combination, any thickness, cellular concrete, precast concrete with
Membrane: Any LL Classified Carlisle EPDM membrane. grouted joists or structural (poured -in- place) concrete. `"
4 Deck: C-15/32 Incline: 1 Membrane: "72 mil Sure -Weld EXTRA" or "80 mil Sure -Weld EXTRA" - '' . • Insulation: Carlisle HP Recovery Board or any UL Classified wood 13. Deck: NC Incline: 1/2 . ' � h 0
fiberboard 1/2 in. thick min. Insulation: See: "Referenced Insulations ", any combination, any thick- ;!
Membrane: Any LL _Classified Carlisle EPDM membrane. ness.
Class. A--- Mechanically_F.astened -(T_P O) . Membrane: '72 mil Sure -Weld EXTRA" or "811 mil Sure -Weld EXTRA ". iri
1 Deck: NC Incline: 1 /2 14. Deck: NC Incline: 1 /2
Insulation: See "Referenced Insulations ", any combination, any thick- Insulation: See: "Referenced Insulations ", any combination, any thick- i � :
Hess. ness. � � -�,-
Membrane: "Sure - Weld ". Membrane: "Sure -Weld FleeceBACK 100 or 115" (TPO).
2. Deck: NC Incline: 1-1/2 15. Deck: NC Incline: 1-1/2 . ? „
Insulation: Carlisle HP Recover Board, 1/2 to 3 in.; Carlisle Recovery Insulation (Optional): Any UL Classified, any thickness.
Board, 1 /2 in min, over any Classified insulation, any combination, any Insulation: 1 /2 in. thick "HP Recovery Board ". ii
'
thickness; cellular concrete, precast concrete with grouted joints or Membrane: "Sure Weld FleeceBACKO 100 or 115" (TPO). -,
rtg
structural (poured -in- place) concrete. 16. Deck: NC Incline: 3
Membrane: "Sure- Weld ".
Insulation: Any UL Classified, any thickness.
3. Deck: NC Incline: 1 -1/2 Barrier Board: 1/4 in. G -P Gypsum Dens - Deck® or 1/2 in. gypsum :..
Insulation: See "Referenced Insulations ", any combination, any thick- wallboard.
Hess.
Membrane: "Sure -Weld FleeceBACK < 100 or 115" (TPO).
Membrane: "Sure -Weld HS" or "Sure -Weld GSD ". 17. Deck: C -13/32 Incline: See Note
4. Deck: NC Incline: 1 -1/2 • Slip Sheet: Two layers Carlisle 'FR Base Sheet ", Elk " VersaShield ;_
Insulation: Carlisle HP Recovery Board, 1/2 to 3 in.; Carlisle Recovery Underlayment" or "VersaShield FB -2S ".
I
Board, 1/2 in. min, over any Classified insulation, any combination, any Insulation (Optional): Any UL Classified (except EPS ), any combina-
thickness; cellular concrete, precast concrete with grouted joints or lion, any thickness.
structural (poured -in- place) concrete. Membrane: Any UL Classified Carlisle TPO membrane.
Membrane: "Sure Weld HS" or "Sure Weld GSD ". Note: Max incline shall be in accordance with Classification estab- :'
5. Deck: NC Incline: 3 lished for the insulation /membrane roofing system, but can not
exceed 2:12.
Insulation (Optional): Any LL Classified, any combination, any thick- Class B - Mechanically Fastened (T P 0)
Hess. 1. Deck: C -15/32 Incline: See Note I,
One mechanically , of one the following:
Barrier Board: 1/2 in. thick gypsum wallboard or 1/4 in. thick G -P Base Sheet: O layer, mechically fastenedf he foll .$
Gypsum Dens - Deck•® g'
Membrane: "Sure-Weld". A.) Owens Corning "Perma Ply No. 28" . . -.E
B.) GAF "Gafglas #75 Base Sheet" .
6. Deck: C -15/32 Incline: See Note C.) Johns Manville "Glasbase" . 1'
Slip Sheet: Two lavers Carlisle "FR Base Sheet ", EIk " VersaShield D.) Tamko "Glass Base" .
Underlayment" or VersaShield FB S ".. E.) Celotex Type G2 "Vaporbar GB" . -
Insulation: Any UL Classified (except EPS), any combination, any F. Carlisle "FR Base Sheet ". 'r
thickness.. G Elk "VersaShield Underlayment" or "VersaShield FB -2S ". • 2 `.
Membrane: Any UL Classified Carlisle TPO membrane. Insulation: See "Referenced Insulations ", min 1 -1/2 in. thickness; • ;F`
Note: Max incline shall he in accordance with Classification estab- Carlisle HP Recovery Board or UL Classified wood fiber board, min 1 in. ;it
lished for the insulation /membrane roofing system, but can not thick; Carlisle HP Recovery Board or UL Classified wood fiber board, :;
exceed 2:12. min 1/2 in. thick over anv Classified insulation (any combination), min . ��
Deck: C -15/32 Incline: Unlimited 1 in. thick. The bottom insulation layer joints are to be staggered a min 6 ,;
Insulation (Optional): Any UL Classified, any combination, any in. from the deck joints. '
thickness. Membrane: Any y Classified Carlisle membrane. ','
Barrier Board: 1/2 in. min gypsum hoard or 1/4 in. thick G -P Gypsum Note: Max incline shall be in accordance with Classification estab-
1
Dens -Deck® with staggered joints (6 in. offset). lished for the insulation /membrane roofing system but not to exceed
Membrane: "Sure -Weld HS" or "Sure -Weld GSD ". 1 in. - .i,'4.
8. Deleted 2. Deck: C -15/32 Incline: See Note
9. Deck: C -15/32 Incline: See Note Insulation: Carlisle HP Recovery Board or UL Classified wood fiber !`
Slip Sheet: One laver Atlas Roofing "FR -10" or "FR -50 ", Carlisle "FR board, min 1 -1/2 in. thick. The bottom insulation laver joints are to be 7. • Base Sheet" or Elk `VersaShield Underlayment" or "VersaShield FB -25 ". staggered a min 6 in. from the deck joints.
Insulation: Atlas Roofing "ACFoam III", 1.5 in. thick with joints Membrane: Any UL Classified Carlisle membrane.
staggered min 6 in. from the deck joints. Note: Max incline shall he in accordance with Classification estab- ; i1. '
Membrane: Any LL Classified Carlisle membrane. lished for the insulation / membrane roofing system but not to exceed i
Note: Max incline shall be in accordance with Classification established 1 in.
for the insulation /membrane roofing system. 3. Deck: C -15/32 Incline: See Note
4 i
10. Deck: C -15/32 roofing Slip Sheet: One layer Carlisle "FR Base Sheet" or Elk "VersaShield I 'N;;
Incline: ]/2 .
Slip Sheet: Two plies Atlas Roofing "FR -50 ". Underlayment" or VersaShield F13-2S ".
Membrane: Any UL Classified Carlisle membrane. Incline: See Note Membrane: Any UL Classified Carlisle TPO membrane. _
r .�.
10 A.Deck: C -15/32 Note: Max incline shall be in accordance with Classification estab- .6
,
Slip Sheet: Two lavers Carlisle "FR Base Sheet" or Elk "VersaShield lished for the membrane roofing system, but can not exceed 1- 1/2:12. _ ; .
Underlayment" or VersaShield FB -2S ". 4. Deck: C-15/32 Incline: 1/2 ._-,.
• Membrane: Am UL Classified Carlisle TPO membrane. Insulation (Optional): Polvisocyanurate, min 1 in. thickness.
Note: Max incline shall be in accordance with Classification established Slip Sheet Two layers Atlas Roofing "FR 50 ", Carlisle "FR Base Sheet"
for the membrane roofing system, but can not exceed 1- 1/2:12. or EIk "VersaShield Underlayment" or "VersaShield FB -2S.
11. Deck: C -15/32 Incline: 2-1/2 Membrane: Any UL Classified Carlisle TPO membrane.
Insulation (Optional): Any UL Classified, anv combination, any 5. Deck: C -15/32 Incline: 1/2 R :
thickness. Slip Sheet: One ply Atlas Roofing "FR -50 ".
Barrier Board: 1/2 in. min y sum hoard. Membrane: "Suer -Weld HS" or "Sure -Weld GSD '. li
'`'
Membrane: '72 mil Sun-Weld EXTRA" or "80 mil Sure -Weld EXTRA" Class C - Mechanically Fastened (T P 0)
12, Deck: NC Incline: 1 -1/2 1. Deck: C -15/32 Incline: 1 s
In sulation: Carlisle HP Recovery Board, 1/2 in. to 3 in., Carlisle Base Sheet: One layer, mechanically fastened, of one of the following: �.
Recover Board, 1,' in. min, over any Classification insulation, any A.) Johns Manville "Perma Ply No. 28 ". "ri`.:
LOOK FOR THE UL MARK ON PRODUCT