Loading...
Permit air "V a CITY OF TIGARD MECHANICAL PERMIT ph :a COMMUNITY DEVELOPMENT Permit #: MEC201000148 Y." Date Issued: 04/06/2010 T i GAR D 13125 SW Hall Blvd., Tigard OR 97223 503.639.4171 f - _x;.:.:;> Parcel: 2S110DD00109 Jurisdiction: Tigard Site address: 11043 SW SUMMERFIELD DR 4 Subdivision: SUMMERFIELD APARTMENTS Lot: 0 Project: Summerfield Apartments Project Description: Vent for stack washer /dryer. Owner: FEES SUMMERFIELD ASSOCIATES, LLC Description Date Amount BY HSC REAL ESTATE, 1500 SW FIRST AVE Permit Fee 04/06/2010 $69.06 STE 1020 12% State Surcharge - Mechanical 04/06/2010 $8.29 PHONE: Contractor: SKYWARD CONSTRUCTION INC 15908 NE 10TH AVE RIDGEFIELD, WA 98642 PHONE: 360 - 546 -1625 FAX: 360- 546 -1630 Type of Use: MF Class of Work: ALT Type of Const: Occupancy Grp: Occupancy Load: Stories: Fuel Air Handlers Fuel Types: Units < 10000 cfm: Gas Pressue: Units > 10000 cfm: Furnaces Boilers & Compressors Furnaces < 100K BTU: 0 -3 HP: Furnaces >= 100K BTU: 3 -15 HP: Floor Furnaces: 15 -30 HP: Unit Heaters: 30 -50 HP: Vents w/o Appliances: 50 or Greater HP: Air Conditioning: Heat Pump: Appliances Vent Fans: Vent Systems: Total $77.35 Hoods: Comm Incinerators: Woodstoves: Gas Fireplaces: Required Items and Reports (Conditions) Clothes Dryers: Other Mech Units: Gas Outlets: Other Desc: Duct Work: Fire /Smoke Dampers: This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952 - 001 -0010 through OAR 952 - 001 -0100. You may obtain a copy of the rules or direct ions : OUNC by calling 503.246.6699 or 1.800.332.2344. Issued y: / , � r�� � Permittee Signal re: ✓A27: • CaII 503.639.4175 by 7:00 a.m. for an inspection that business day. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. v 1-''."111 F Mechanical Permit Application 1 , � k wi.ivesr. �tt s r�s r,wrr era>usau.It„ ids (Fti 'i a Rec eive d ,rt µ City of Tigard ' Permit No 6 r DateBY I/ 4, /O �. it N Y' E ,0204:::, �`f b a 9 ! q 13125 SW Hall Blvd., Tigard, OR 97223 APR 0 6 2010 Plan Review 4 Phone: 503.639.4171 Fax: 503.598.1960 Date/By: Other Permit: N'' !' Inspection Line: 503.639.4175 I +I t i\ i t IJ ne: WARD Date Ready/By: runs: Fa See Page 2 for "0 J 7 fi Internet: www.tigard-or.gov 1 , 1 r tiu Notified/Method: Supplemental Information TYPE OF WORK COMMERCIAL FEE* SCHEDULE - USE CHECKLIST Mechanical permit fees* are based on the value of the work ❑ New construction 07: Addition/alteration/replacement performed. Indicate the value (rounded to the nearest dollar) of all ❑ Demolition ❑ Other: mechanical materials, equipment, labor, overhe�� ad, and profit. CATEGORY OF CONSTRUCTION . El I- and 2- family dwelling ❑ Commerciallindustrial RESIDENTIAL EQUIPMENT / SYSTEMS FEES* ❑ Accessory building For special information use checklist. ❑ Multi- family ❑ Master builder ❑ Other: Description Qty. I Ea. I Total JOB SITE INFORMATION AND LOCATION Heating/cooling Job site address: 0 1Wrilf41�t Air conditioning 6.2 .i��l ;j _ (requires site plan showing placement) 46.75 City /State /ZIP: i , a , - 1 0 Az)„ 4-2 � 7� y Furnace 100,000 BTU ( ducts /vents) 46.75 ' Furnace 100,000+ BTU (ducts/vents) 54.91 Suite/bldg. /apt. no.: "itt i f Project name: L. / Heat pump 61.06 Cross street/directions to job site: Duct work 23.32 Hydronic hot water system 23.32 Residential boiler (radiator or hydronic) 23.32 Unit heaters (fuel -type, not electric), in -wall, in -duct, suspended, etc. 46.75 Flue /vent for any of above 23.32 Subdivision: Lot no.: Other: 23.32 Tax map /parcel no.: Other fuel appliances DESCRIPTION OF WORK Water heater 23.32 � Gas fireplace 33.39 I T P� - t - Q r"' S. 'lit C r„. //l Flue vent for water heater or gas / fireplace 23.32 Log lighter (gas) 23.32 Wood/pellet stove 33.39 Wood fireplace /insert 23.32 >Z1 PROPERTY OWNER I ❑ TENANT Chimney /liner /flue /vent 23.32 Other: 23.32 Name: J/SG ✓ f p at 1r5 t A Environmental exhaust and ventilation Address: ' p 5 >4- 62 Range hood/other kitchen Gre _ S f i /b ;LC equipment 33.39 City /State /ZIP: p `t 'f - / a 0 l q. . / Clothes dryer exhaust ' 33.39 Single -duct exhaust (bathrooms, Phone: (S-0,3) Sys S _ 3o f Fax: ( Sb j ) .. y‘_, S 36 / toilet compartments, utility rooms) 23.32 ® APPLICANT ❑ CONTACT PERSON Attic /crawlspace fans 23.32 Business name: ` •J / Other: 23.32 J [` }/ r; car cl G A si i Fuel piping Contact name: ,. / C $14.15 for first four; $4.03 for each additional Address: ! 5 Q�j p N 't Furnace, etc. �JQ V e Gas heat pump City /State /ZIP: /i. d ` c; . ( , u Am, q q 2 Wall/suspended/unit heater Phone: g6 e ) 5- y /6 Fax: : (3CO) S a .fit, Water heater Fireplace E -mail: Range CONTRACTOR . Barbecue Business name: a k 1 Lk/ a .4 Co Ad , Clothes dryer (gas) Other: Address: [L 2 C � i.' MECHANICAL PERMIT FEES* J C ity /State /ZIP: 5 Q Subtotal . Phone: ( ) Fax: ( ) Minimum permit fee ($90.00) Plan review (25% of permit fee) - CCB lic.: / 5 J ' 9 State surcharge (12% of permit fee) p • /` /! TOTAL PERMIT FEE 7 7 35 // This permit application expires if a permit is not obtained within 180 Authorized signatu �: days after it has been accepted as complete. Print name: " 4 4.1 Date: y -o - j �,t * Fee methodology set by Tri County Building Industry Service Board 1:\ Bui1ding Wermits\MEC- PermilApp.doc 10/01/09 440- 4617T(11/02/COM/WEB)