Permit . ,. , , TIGARD BUILDING PERMIT
PE RMIT #: BUP2004 00303
� _�I� l DEVELOPMENT SERVICES DATE ISSUED: 6/23/2004
13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 PARCEL: 1S135AB 00203
SITE ADDRESS: 09120 SW LOCUST ST
SUBDIVISION: TOWN OF METZGER ZONING: R -4.5
BLOCK: LOT: 005 JURISDICTION: TIG
REISSUE: FLOOR AREAS EXTERIOR WALL CONSTRUCTION
CLASS OF WORK: DEM FIRST: sf N: S: E: W:
TYPE OF USE: SF SECOND: sf PROJECT OPENINGS?
TYPE OF CONST: 5N : sf N: S: E: W:
OCCUPANCY GRP: R3 TOTAL AREA: 0 sf ROOF CONST: FIRE RET?
OCCUPANCY LOAD: BASEMENT: sf AREA SEP. RATED:
STOR: HT: ft GARAGE: sf OCCU SEP. RATED:
BSMT ?: MEZZ ?: REQD SETBACKS REQUIRED
FLOOR LOAD: psf LEFT: ft RGHT: ft FIR SPKL: SMOK DET:
DWELLING UNITS: FRNT: ft REAR: ft FIR ALRM : HNDICP ACC:
BEDRMS: BATHS: IMP SURFACE: PRO CORR: PARKING:
VALUE:
Remarks: Demolition of 1834 square foot house and 528 square foot garage. All demolition debris is to be removed and
sewer is to be capped. SDC credits to apply to new construction.
Owner: Contractor:
TIGARD TUALATION SCHOOL DISTRICT #2 EMMERT INTERNATIONAL
6960 SW SANDBURG RD 11811 SE HWY 212
TIGARD, OR 97223 CLACKAMAS, OR 97015
Phone: 503 - 620 -1620
Phone: 655 -7191
Reg #: LIC 805
FEES REQUIRED INSPECTIONS
Description Date Amount Ersn Cntrl 681 -4444
[BUILD] Permit Fee 6/23/2004 $62.50 Cap Sewer Line Insp
[TAX] 8% State Surcharl 6/23/2004 $5.00 Final Inspection
[ERPRMT] Erosion 6/23/2004 $26.00
[ERPLN] Ero Plck -CWS 6/23/2004 $8.45
(additional fees not listed here)
Total $110.40
This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes
and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is
not started within 180 days of issuance, or if work is suspended for more than 1 80 days. ATTENTION: Oregon law
requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR
952-001-1g : ; - • h OAR 952 -00 e ! 0. You may obtain a copy of these rules or direct questions to OUNC by
callin• 503) 246 -6699 • 1- 800 -33
Issu d By: � :_ _ , 0 ' i r
Permittee PANLARSLik / Signature: A
Call 639 , 175 by p.m. for an inspection the next business day
Building Permit Application FOR OFFICE USEONLY ':: ,
Received �
City of Tigard Date/By: ir��7 d Permit No.: 1 --CO&
13125 SW Hall Blvd., Tigard, OR 97223 Plan Review
Phone: 503.639.4171 Fax: 503.598.1960 I 'i '� Date/By: Other Permit:
Inspection Line: 503.639.4175 a'f ' Date Ready/By: m See Attached Checklist for
Internet: www.ci.tigard.or.us Notified/Method: I Supplemental Information
. TYPE OF WORK REQUIRED DATA i1 AND2 FAMILY DWELLING
❑New construction ❑Demolition Permit fees* are based on the value of the work performed.
Indicate the value (rounded to the nearest dollar) of all
❑ Addition/alteration/replacement ❑ Other: equipment, materials, labor, overhead, and the profit for the
t CATEGORY `OF CONSTRUCTION
x
work indicated on this application.
,
Valuation: $
❑ 1- and 2- family dwelling ❑ Commercial /industrial
❑ Accessory building ❑ Multi - family Number of bedrooms:
❑ Master builder ❑ Other: Number of bathrooms:
JOB. SITE INFORMATIONAND LOCATION; Total number of floors:
Job site address: Cl 12.0 SW LociASk- New dwelling area: square feet
City/State /ZIP: VbfL.31,,,rr1 It OD g 1 2-Z3 Garage /carport area: square feet
Suite/bldg. /apt. no.: Project name: DGN 5G+1 NL-J itG I I Covered porch area: square feet
Cross street/directions to job site: Deck area: square feet
Other structure area: square feet
REQUIRED - DATA• COMMERCIAL USE CHECKLIST
Subdivision: Lot no.: Permit fees* are based on the value of the work performed.
Tax map /parcel no.: Indicate the value (rounded to the nearest dollar) of all
equipment, materials, labor, overhead, and the profit for the
DESCRIPTION OF ,WORK - work indicated on this application.
, dy 59- Sei ., :.., ., ..�, .... .,. Valuation: $
fOLLbir — 1 cZ (i Co
! JC. 1Hr) - HO D i.- 4.1DULS rl. "1 GI/S 7-2O0 Existing building area: square feet
O PT p f ��Q . / New building area: square feet
® PROPERTY .OWNER; ❑ TENANT , Number of stories:
Name: I,ga✓d , Tut 1' hh s- cJ j 1)).'l'j41-- Type of construction:
Address: L'1 ( Q() cO A aohu.Q6► p�, Occupancy groups:
City/State /Z1PrTir if leb Ot2._ ll 9-9- - 5 Existing:
Phone: (M3) &2a0 .- 1 p90 Fax: ( ) New:
❑ :: t':: ® " P ERSON ;
. � � - _,.. .. NOTICE
Business name: All contractors and subcontractors are required to be
Contact name: licensed with the Oregon Construction Contractors Board
under ORS 701 and may be required to be licensed in the
Address: jurisdiction in which work is being performed. If the
City/State /ZIP: applicant is exempt from licensing, the following reasons
apply:
Phone: ( ) Fax:: ( )
E -mail:
` = %'CONTRACI"OR.
Business name: EjMymeAr j MIA INZI - cam t L.
- BUILDING PERIVIIT:FEES
Address: ) I % 1 l Si'� )4W' J
Please refer to fee schedule.
City/State/ZIP: eL3aGU0-yviOS op- 8 10 )5
Fees due upon application
Phone: (603) X54 ' ' 7jj i Fax: (563 ) 7 - 3443
Amount received
CCB lic.:
Date received:
Authorized signature: t 0 This permit application expires if a permit is not obtained
within 180 days after it has been accepted as complete.
Print name: L / AI I C Hitt& 1.4171P11-- 4 Date: (p i 2 3 I ZDD 9 * Fee methodology set by Tri-County Building Industry
/ Service Board. //D J0
i:\Building \Permits \BUP- PermitApp.doc 12/03 440- 4613T(l1 /02/COM/WEB) 7 C/
•
One- and Two- Family Dwelling -
�r+
Building Permit Application Checklist FOR <OFFICE aUSErONLY °"
� tf
City of Tigard Received Permit No.:
13125 SW Hall Blvd., Tigard, OR 97223 Date/By:
Phone: 503.639.4171 Fax: 503.598.1960 /Mi r , I 1 Associated permits:
24- Hour Inspection Line: 503.639.4175 i. 4 �, I ?, ❑ Electrical ❑ Plumbing ❑ Mechanical
Internet: www.ci.tigard.or.us "' ❑Other:
� � 1 . � ... �,. ._ -'__ �_.
,,. u,3 r , A, � * . ITEMS. ARE- REQUIRED.FOR
1 Land use actions completed. See jurisdiction criteria for concurrent reviews. ❑ E ❑
2 Zoning. Flood plain, solar balance points, seismic soils designation, historic district, etc. ❑ ❑ ❑
3 Verification of approved plat/lot. ❑ ❑ ❑
4 Fire district approval required. Name of district: ❑ ❑ ❑
5 Septic system permit or authorization for remodel. Existing system capacity ❑ ❑ ❑
6 Sewer permit. ❑ ❑ ❑
7 Water district approval. ❑ ❑ ❑
8 Soils report. Must carry original applicable stamp and signature on file or with application. ❑ ❑ ❑
9 Erosion control ❑ plan ❑ permit required. Include drainage -way protection, silt fence design and location of catch- ❑ ❑ ❑ •
basin protection, etc.
10 3 Complete sets of legible plans. Must be drawn to scale, showing conformance to applicable local and state ❑ ❑ ❑
building codes. Lateral design details and connections must be incorporated into the plans or on a separate full -size
sheet attached to the plans with cross references between plan location and details. Plan review cannot be completed if •
copyright violations exist.
11 Site /plot plan drawn to scale. The plan must show lot and building setback dimensions; property corner elevations (if ❑ ❑ ❑
there is more than a 4 -ft. elevation differential, plan must show contour lines at 2 -ft. intervals); location of easements
and driveway; footprint of structure (including decks); location of wells /septic systems; utility locations; direction
indicator; lot area; building coverage area; percentage of coverage; impervious area; existing structures on site; and
surface drainage.
12 Foundation plan. Show dimensions, anchor bolts, any hold -downs and reinforcing pads, connection details, vent size ❑ ❑ ❑
and location.
13 Floor plans. Show all dimensions, room identification, window size, location of smoke detectors, water heater, ❑ ❑ ❑
furnace, ventilation fans, plumbing fixtures, balconies and decks 30 inches above grade, etc.
14 Cross section(s) and details. Show all framing- member sizes and spacing such as floor beams, headers, joists, sub- ❑ ❑ ❑
floor, wall construction, roof construction. More than one cross section may be required to clearly portray
construction. Show details of all wall and roof sheathing, roofing, roof slope, ceiling height, siding material, footings
and foundation, stairs, fireplace construction, thermal insulation, etc.
15 Elevation views. Provide elevations for new construction; minimum of two elevations for additions and remodels. ❑ ❑ ❑
Exterior elevations must reflect the actual grade if the change in grade is greater than four foot at building envelope.
Full -size sheet addendums showing foundation elevations with cross references are acceptable.
16 Wall bracing (prescriptive path) and/or lateral analysis plans. Must indicate details and locations; for non ❑ ❑ ❑
prescriptive path analysis provide specifications and calculations to engineering standards.
17 Floor /roof framing. Provide plans for all floors /roof assemblies, indicating member sizing, spacing, and bearing ❑ • ❑ ❑
locations. Show attic ventilation.
18 Basement and retaining walls. Provide cross sections and details showing placement of rebar. For engineered ❑ ❑ • ❑
systems, see item 22, "Engineer's calculations."
19 Beam calculations. Provide two sets of calculations using current code design values for all beams and multiple joists ❑ ❑ ❑
over 10 feet long and/or any beam/joist carrying a non - uniform load.
20 Manufactured floor /roof truss design details. ❑ ❑ ❑
21 Energy Code compliance. Identify the prescriptive path or provide calculations. A gas- piping schematic is required ❑ ❑ ❑
for four or more appliances.
22 Engineer's calculations. When required or provided, (i.e., shear wall, roof truss) shall be stamped by an engineer or ❑ ❑ ❑
architect licensed in Ore: on and shall be shown to be applicable to the •ro under review.
T JURISDICTIONAL: SPECIFICS ._ ' H';�f'
23 Five (5) site plans are required for Item 11 above. Site plans must be 8 -1/2" x 11" or 11" x 17 ". ❑ ❑ ❑
24 Two (2) sets each are required for Items 16, 19, 20 and 22 above. ❑ ❑ ❑
25 Building plans shall not contain red lines or tape -ons. "Mirrored" building plans will not be accepted. ❑ ❑ ❑
26 "Reversed" building plans must meet criteria outlined in the Permit & System Development Fees document. ❑ ❑ ❑
27 "Drawn to scale" indicates standard architect or engineer scale. ❑ ❑ ❑
28 Site plan to include tree size, type and location per approved project street tree plan (if applicable), and City of Tigard ❑ ❑ ❑
Street Tree List.
29 Site plan to include tree protection measures as required by conditions of approval. ❑ ❑ ❑
30 A Clean Water Services' Sensitive Area Pre - Screening Site Assessment form is required for all building additions, ❑ ❑ ❑
including decks, patio covers (over non - impervious surface) and accessory structures to existing residential dwellings
on a lot of record approved prior to September 9, 1995.
•
i:\Building\Permits \One - Two- FamilyChecklist.doc 12/03