Loading...
Permit i E rt u i ���� OF TIGARD FIRE PROTECTION SYSTEM PERMIT • p v o COMMUNITY DEVELOPMENT Permit #: FPS2009 -00106 T t Gi\RD 13125 SW Hall Blvd., Tigard OR 97223 503.639.4171 Date Issued: 12/08/2009 Parcel: 1S136AD06503 Jurisdiction: TIGARD Site address: 10900 SW 68TH PKWY Subdivision: WAY LEE Lot: 2 Project: Changs Mongolian Grill Project Description: Fire suppression for kitchen hood. Owner: FEES WAY W LEE GENERAL CONTRACTOR Description Date Amount 5210 SE 26TH AVE PORTLAND, OR 97202 Permit Fee - COM 11/03/2009 $102.20 12% State Surcharge - Building 11/03/2009 $12.26 PHONE: Plan Review - Fire Life Safety - COM 11/03/2009 $40.88 Contractor: HUSER SALES & SERVICE INC 231 N TILLAMOOK ST PORTLAND, OR 97227 PHONE: 503 - 248 -1948 FAX: 503 - 248 -7077 Type of Use: COM Class of Work: ALT Type of Const: VB Occupancy Grp: A -2 Height: ft Stories: 1 Commercial Sprinkler System: Sprinkler Required: Yes Sprinkler Type: Standpipe Required: No Hazard: Density: Design Area: K Factor: Commercial Fire Alarm System: Fire Alarm Required: Alarm Type: Pull Station Required: Smoke Detectors Req: Battery Calcs Provided: Cut Sheets Required: Total $155.34 Valuations: Required Items and Reports (Conditions) Sprinkler Valuation: 3000 Residential Square Footage: Fire Alarm Valuation: This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by th,Or-. 4 n Utility Notification Center. Those rules are set forth in OAR 952 - 001 -0010 through OAR 952 - 001 -0100. You may obtain a copy of -e u -s or direct questions to OUNC by calling 503.246.6699 or 1.800.332.2344. i / Issued By: elfibta • / ` . - A ' Permittee Signature: / / Call 503.639.4175 by 7:00 a.m. for an inspection that business day. This permit card shall be kept in a conspicuous place on the job site until completi.n of the project. Approved plans are required on the job site at the time of each inspection. Building Permit Application , Fire Protection System RECEIVED FOR OFFICE USE ONLY Received Permit No.: r City of Tigard NOV 0 3 2009 DateB : /1 a -� �Si�i�! / r 1111 13125 SW Hall Blvd., Tigard, OR 97223 1 Plan Review ,`�� Phone: 503.639.4171 Fax: 503.598.196 DateB .tom Other Permit: T 1 G AR D Inspection Line: 503.639.4175 ` CITY OF TIGARD Date Re ; : � QQ � Juri / s See Page 2 for Internet: www.tigard or.gov B UILDING DIVISION Notified/Method: g. 0 c l ('' �/ /( Supplemental Information TYPE OF WORK REQUIRED DATA: 1- AND 2- FAMILY DWELLING N New construction ❑ Demolition Permit fees* are based on the value of the work performed. Indicate the value (rounded to the nearest dollar) of all ❑ Addition/alteration/replacement 0 Other: equipment, materials, labor, overhead, and the profit for the CATEGORY OF CONSTRUCTION work indicated on this application. Valuation: $ ❑ 1- and 2- family dwelling ❑ Commercial /industrial ❑ Accessory building El Multi-family Number of bedrooms: ❑ Master builder ❑ Other: Number of bathrooms: JOB SITE INFORMATION AND LOCATION Total number of floors: Job site address: 10900 SW 68 Pkwy New dwelling area: square feet City /State /ZIP: Tigard OR 97223 Garage /carport area: square feet Suite/bldg. /apt. no.: Project name: `V\p t -,3 eak., LL Covered porch area: square feet Cross street/directions to job site: SW 68 Pkwy and SW Pacific Hwy Deck area: square feet Other structure area: square feet REQUIRED DATA: COMMERCIAL -USE CHECKLIST Subdivision: Lot no.: Permit fees* are based on the value of the work performed. Indicate the value (rounded to the nearest dollar) of all Tax map /parcel no.: equipment, materials, labor, overhead, and the profit for the DESCRIPTION OF WORK work indicated on this application. Installation of Automatic Kitchen Hood fire suppression system Valuation: $ S (-) C5 U Existing building area: square feet New building area: square feet ❑ PROPERTY OWNER El TENANT Number of stories: Name: `, �h y\ L) ; i i 0. /t S oil Type of construction: Address: Occupancy groups: City /State /ZIP: Existing: Phone: (c ) 511 57 1 6 Fax: ( ) New: APPLICANT ❑ CONTACT PERSON NOTICE Business name: /tt.ISw' c \ICS i Se ■'%.; I (C' 1 et- C All contractors and subcontractors are required to be licensed with the Oregon Construction Contractors Board Contact name: D6t1 > 1 falt. Y\ under ORS 701 and may be required to be licensed in the Address: 23 i >ti/ ► ; (kA/tit c,�, jurisdiction in which work is being performed. If the applicant is exempt from licensing, the following reasons City/State /ZIP: C, f (J'iO' (,)/: ( - 1 7 _ 2. 7 apply: PP Y: Phone: ('3c3 ) 7,Y.' - •tqQ Fax:: ( ) E -mail: L kl:jt' ,'I ='1 - C. CONTRACTOR BUILDING PERMIT FEES* Business name: /� s S c' (J 1` F' 1,� C (Please refer to fee schedule) Hu Permit fee: Address: 23i N T, (+,` o d State surcharge (12% of permit fee): City /State /ZIP: �Gi`iAirn d Cr .)e `"( L'L I n FLS plan review (40% of permit fee): Phone: (`' ) - ( q 9 g /' ' Fax: (.._ ) Z j -'� t; -[ i (Due upon application.) � Z • CCB lic.: { l 6 ( 541 g. /d Total permit fees: a. Amount received: Authorized signature: / I This permit application expires if a permit is not obtained Print name: "aid / A /g� � N Date: / v / �i within 180 days after it has been accepted as complete. * Fee methodology set by Tri -County Building Industry Service Board. 1:\ Building \Permits \FPS- PermitApp.doc 10/01/09 440- 4613T(11/02/COM /WEB) City of Tigard: Fire Protection Permit Checklist Page 2 - Supplemental Information Describe work to be done: 1.) L New 2.) Modification to sprinkler heads only: Addition ❑ 1 -10 heads: No plan review required. ❑ Alteration ❑ 11+ heads: Plan review required. ❑ Repair Number of sprinkler heads: Additional description of work: Type of System (Complete A, B, C or D as applicable): A.) Commercial Sprinkler ❑ Wet ❑ Dry Additional Standpipes Information: Hazard Group Density Design Area K. Factor Sprinkler Project Valuation: $ B.) Type I - Hood Fire Suppression System Hood Project Valuation: $ ,3 ooc C.) Fire Alarm Submittal shall Battery Calculations ❑ Yes include: Individual Component ❑ Yes Cut Sheets Fire Alarm Project Valuation: $ D.) Residential Sprinkler (Stand Alone System) Square Footage: Permit Fee: 0 to 2,000 $198.75 2,001 to 3,600 $246.45 3,601 to 7,200 $310.05 7,201 and greater $404.39 Sprinkler Project Square Footage: sq. ft. Fire Protection Permit Fees Project valuation subtotal (see A, B & C above): $ 3, oov Permit fee based on project valuation (see fee schedule): $ 1 0 ti Permit fee based on square footage (see D above): $ State Surcharge (12% of permit fee): $ 1 Z . .Z� FLS Plan Review (40% of permit fee): $ 1 TOTAL: $ j55. Plan review requires a completed application and 2 sets of plans at submittal. Plan review fees are required at submittal. http: / /www.tigard- or.gov/ city_ hall / departments /cd /dots /F'PS- PermitApp.doc 10/01/() 4 ' Installation of two Ansul R -102 Restaurant Fire Suppression g a9. 9 1 Systems. 0 -. General Notes: 1 3, z� r 1. System Design and maintanance to be in accordance with 1`�" x NFPA 17A, 96, any other applicable NFPA standards as I®t ',_ , S 3 �� C n : required for a particular application and design and Ansul R102 n '/' a '11 > C7 o Resteraunt Fire Suppression Systems. is zs Q 2. This drawing shows protection of the appliances, plenums ► Z O `n tri and duct. I 1 = 3 g.k l 7 t7 "3 c� o 3. Agent cylinder is located next to hoods. ® W ` s - ° < G7 N IV t,, a o 4. All piping will be schedule 40 black e" and be securely !1i g = � *%c ► O cc fastened. ` 1 kli I, i . ,,.., 6. Manual Release shall be located a minimum of 10' and a maximum of 20' from the kitchen exhaust system. ` ►® • ' 010 7. Exhaust air shall remain on during discharge. Make up air W" ' M ^ ^ "'O shall shut down, E A .a.... O II C I ) 8. Upon discharge all sources of fuel and power to all -C.; Wok O O 1QQ appliances and outlets located under the hood shall be shut TO FUSIBLE down. LINKS TO MANUAL a 0 Wok O E 9. Fire Suppression System must be tied in to activate building E E fire alarm or sprinkler system if applicable. Wok 1 2 0 0 \ GAS SHUT OFF NOZZLE CHART APPLICATION NOZZLE LOCATION MAXIMUM HAZARD AREA SIZE NOZZLE QUANTITY =LOW COUNT HOOD CENTER 10' X 4' max length 8 -0' 1N 1 1 Bill Of Materials Item Qty Part Number Description DUCT CENTER 100' max Perm. 20'x14' 2W 1 2 1 2 430309 3.0 Gallon Mechanical Release Assembly WOK 14' -30' 8' max depth 3w 260 3 6 TOTALS - - - - 5 9 - _ 2 2 423441 101 -20 CO2 Cartridge 4 3 419341 260 Nozzles 5 2 419337 2W Nozzles Customer Project 6 6 419335 1N Nozzles HUSER Grening Construction Inc. Chang's Mongolian Grill 7 2 4835 Remote Manual Pull Station Fire Fighting Equip. 811 NE Countryside Dr 10900 sw 68th Parkway 231 N Tllamookst Vancouver, WA 98684 Tigard OR 97223 8 4 417369 Scissor Style Detectors Portland, OR 97227 9 1 55601 1" Mechanical Gas Valve 5031248.194e Ansul R -102 Restaurant Fire Suppression System Page 1 of 2 TO FUSIBLE LINKS TO MANUAL A �, Q RELEASE 12 a „L. _ ,. GAS SHUT OFF Q © • • NOZZLE CHART APPLICATION NOZZLE LOCATION MAXIMUM HAZARD AREA SIZE NOZZLE QUANTITY =LOW COUNT 4' Griddle HOOD CENTER 10' X 4' max length 5-0' IN 1 1 DUCT CENTER 100' max perm. 20' x 20' 2W 1 2 GRIDDLE 35' - 40' 36' longest side 4' diameter IN 4 4 TOTALS - - - • 6 7 Customer Project HUSER Grening Construction Inc. Chang's Mongolian Grill Fire Fighting Equip. 811 NE Countryside Dr 10900 sw 68th Parkway 231NTiUamookst Vancouver, WA 98684 Tigard OR 97223 Portland. OR 97227 (503)248 -1948 Ansul R -102 Restaurant Fire Suppression System . I Page 2 of 2 SECTION III — SYSTEM COMPONENTS UL EX. 3470 ULC CEx747 Page 3 -1 4 -1 -06 REV.5 EXTINGUISHING AGENT ANSULEX Low pH Liquid Fire Suppressant (1.5 gallon — Part No. "ANSUL AUTOMAN" REGULATED RELEASE ASSEMBLY 79694 or 3.0 gallon — Part No. 79372) is a potassium -based solu- (MECHANICAL) tion designed for fast knock -down and suppression of grease - related fires. The agent is shipped in plastic containers which pro- NOTE: AGENT TANK MUST BE complete tank charge. (Refer to Section V, Page 5 -2.1, for ORDERED PAGE • vide one com P 9 ( g OR SEE PAGE 3 -4 • maximum agent fill capacity.) Agent storage life expectancy is twelve years. The distributor must record the batch numbers and RELEASE date of shipment receipt to be filed with each installation record. MECHANISM 'ANSULEX" LOW pH LIQUID FIRE SUPPRESSANT ,,,,,,, 1 4,,,_ , 1 t ,iii 1 114 . -44% REGULATOR l 3.0 GALLON 1.5 GALLON SHIPPING WT. 25 I.B. (11 kg) SHIPPING WT. 35 LB. (16 kg) SHIPPING WT. 19 LB. (9 kg) 000130 00017 FIGURE 2 FIGURE 1 000133 REGULATED RELEASE ASSEMBLY (MECHANICAL) REGULATED RELEASE ASSEMBLY (ELECTRICAL) The ANSUL AUTOMAN Regulated Mechanical Release Assembly The ANSUL AUTOMAN Regulated Electrical Release Assembly (Part No. 429853) contains the regulated release mechanism, (Part No. 429856) is identical to the mechanical version except it expellant gas hose for agent tank hookup, and enclosure knock- also contains a factory installed 120 VAC solenoid and electrical outs to facilitate installing actuation piping; expellant piping; detec- switch. tion system; and additional equipment. This regulated release The solenoid is used to provide electrical actuation of the release assembly is used in single, double, and multiple -tank systems and mechanism. The electric switch is used to protect the solenoid by must be mounted to a rigid surface. The release mechanism can opening the circuit to the solenoid once the system is fired. be used to interconnect both the actuation and expellant gas lines Additional electrical switches can be added as required for auto as required per system design. The regulator is designed to allow matic equipment and gas shut -off accessories, as well as initiating a constant flow of gas into the tank at 110 psi (759 kPa) when the audible and visual alarms. system is actuated. The agent tank must be ordered separately. In single, double, and multiple -tank systems, the provided expel- " ANSUL AUTOMAN" REGULATED RELEASE ASSEMBLY lant gas hose connects the agent tank to the bottom outlet of the . (ELECTRICAL)' regulator. In double and multiple -tank system configurations, the back outlet of the regulator is used as an expellant gas feed for NOTE: AGENT TANK MUST BE ORDERED one additional tank - enclosure or tank - bracket hookup. The enclo- SEPARATELY sure contains the required knockouts to facilitate this connection. OR SEE PAGE 3-4 If a pressure switch is to be attached to the regulator, additional fit- 41111111 tings are required. REGULATOR ^ !�e -I 4 1 SWITCH The tank is mounted within the enclosure. The tank contains an y ,�',► - ad /tube assembly with a burst disc union. The burst disc rl`11%�N helps prevent siphoning of the agent up the pipe due to significant '� temperature fluctuations in the area where the tank is located. The \ I 17 SOLENOID tank is mild steel and, under normal conditions, requires hydrosta- �:�{. tic testing every twelve years. `0 The detection and additional equipment required per system design are connected to the release mechanism. The enclosure I contains knockouts to facilitate detection and additional hookups. The system can be actuated automatically or manually. Automatic actuation occurs when a fusible link within the detection system F SHIPPING WT. 34 LB. (15 kg) separates in a fire condition. Manual actuation of the system i occurs when personnel pull on the remote manual pull station pull ring. FIGURE 3 000,39 . • NOTE: ANSUL AUTOMAN Regulated Electrical Release, Part No. 429856, is not ■ intended to be used with electric detection. • SECTION III — SYSTEM COMPONENTS UL EX. 3470 ULC CEx747 Page 3 -3 4 -1 -06 REV.8 AGENT TANK ASSEMBLY OEM REGULATED ACTUATOR ASSEMBLY The agent .tank shipping assembly (3- Gallon, Part No. 429862, The OEM Regulated Actuator Assembly, Part No. 418691, and 1.5 Gallon, Part No. 429864) consists of a stainless steel tank includes the regulator, pneumatic actuator, expellant gas hose and and an adaptor/tube assembly. The adaptor/tube assembly con- OEM bracket. Also available is an OEM Regulated Actuator tains a burst disc. The burst disc prevents agent leakage due to Assembly with all the above mentioned components except for the significant temperature fluctuations in the area where the tank is bracket. This assembly is Part No. 418522. located. Under normal conditions, the tank requires hydrostatic testing every twelve years. The date of manufacture is stamped on the tank nameplate. The tank is shipped uncharged and must be filled with only ANSULEX Low pH Liquid Fire Suppressant during installation. TANK ADAPTOR/ 17� TUBE ASSEMBLY Oil 3 GALLON 1 SHIPPING WE 7 LB. (3 kg) 1.5 GALLON SHIPPING WT 5 LB. (2 kg) AGENT SHIPPING WT. 4 LB. (2 kg) TANK FIGURE 10 002225 TWO TANK ENCLOSURE ASSEMBLY FIGURE 8 The Two Tank Enclosure Assembly, Part No. 429872, consists of 000140 two expellant gas hoses, two grommets, and the mounting enclo- OEM RELEASE/BRACKET ASSEMBLY sure. The assembly is used in 9 gallon systems. It can be coupled (FOR OEM IN- CABINET USE ONLY) with a 3- gallon regulated release assembly or a 3- gallon regulated actuator assembly to give a total of 9 gallons of agent. Agent tanks The OEM Regulated Mechanical Release/Bracket Assembly, Part must be ordered separately. No. 79493, contains the same regulated release mechanism as The tank enclosure is designed to mount in a minimum amount of the standard ANSUL AUTOMAN Regulated Release Assembly. space. The OEM Regulated Electrical Release/Bracket Assembly, Part • No. 418054 *, is identical to the mechanical version except it con- tains a factory installed 120 VAC solenoid and electrical switch. These release/bracket assemblies must be installed in a suitable equipment enclosure either horizontally or vertically. They contain all the necessary mounting and conduit holes needed to fully install the assembly. The agent tank is installed separately and need not be bracketed once it is piped and filled. Note: OEM Release/Bracket Assembly must be installed high enough in cabi- net so that there is sufficient room to install and remove cartridge. ►'Note: OEM Regulated Electrical Release/Bracket Assembly, Part No. 418054, is I L not intended to be used with electric detection. 1 RELEASE • MOUNTING MECHANISM - -►I�i Q �� BRACKET REGULATOR 00 SHIPPING WT. 10 LB. (5 kg) FIGURE 9 000144 • SECTION III — SYSTEM COMPONENTS UL EX. 3470 ULC CEx747 Page 3 -4 REV. 7 4 -1-06 24 VDC REGULATED RELEASE ASSEMBLY (ULC APPROVED ADDITIONAL SHIPPING ASSEMBLIES ONLY) Several complete shipping The 24 VDC Regulated Release Assembly, Part No. 429859, is p Aping assemblies are available a ntainien g Y both the release or actuator mechanism and the agent tank. When used where electric, thermostat detection is required via the use of ordering a complete shipping assembly, order the following part a releasing control unit. This assembly consists of a 24 VDC numbers: ANSUL AUTOMAN II -C regulated release mechanism, expellant gas hose, and enclosure knockouts to facilitate installing actuation Shipping Wt. piping, expellant piping, detection system, and additional equip- Part No. Description Ib. (kg) ment. Agent tank must be ordered separately. 430299 3.0 Gallon Mechanical Release 33 (15) The system can be actuated automatically or manually. Automatic Shipping Assembly including: actuation occurs when the control panel receives a signal from the 429853 Mechanical Regulated detection circuit. The panel then sends an electrical signal to the Release Assembly 24 VDC regulated release, causing it to actuate. When actuation 429862 3.0 Gallon Tank Assembly occurs, the gas cartridge is punctured, pressurizing the agent tank 430300 1.5 Gallon Mechanical Release 30 (14) and discharging the agent through the distribution piping. Manual Shipping Assembly including: actuation of the system occurs when personnel pull on the remote 429853 Mechanical Regulated manual pull station pull ring. Release Assembly 429864 1.5 Gallon Tank Assembly 44A111°11, NOTE: AGENT TANK MUST BE ORDERED SEPARATELY 430309 3.0 Gallon Regulated Actuator 36 (16) 4 Shipping Assembly including: SHIPPING WE 429850 Regulated Actuator Assembly , 34 LB. (15 kg) 429862 3.0 Gallon Tank Assembly ill 430316 1.5 Gallon Stainless Steel Enclosure 18 (8) Shipping Assembly including: O 429870 Single Tank Mounting Box Assembly 429864 1.5 Gallon Tank Assembly 418511 Hose Assembly _ 430317 3.0 Gallon Stainless Steel Enclosure 20 (9) FIGURE 12 Shipping Assembly including: 002279 429870 Single Tank Mounting Box Assembly 429862 3.0 Gallon Tank Assembly 418511 Hose Assembly 430324. 6.0 Gallon Stainless Steel Enclosure 40 (18) Shipping Assembly including: 429872 Two Tank Mounting Box Assembly 429862 3.0 Gallon Tank Assembly (2) 430332 3.0 Gallon Mounting Bracket Shipping 20 (9) Assembly including: 429878 3.0 Gallon Mounting Bracket Assembly 429862 3.0 Gallon Tank Assembly SECTION III - SYSTEM COMPONENTS UL EX. 3470 ULC CEx747 Page 3 -5 3 -1 -07 REV.7 GAS CARTRIDGES NOZZLES The R -102 system uses gas cartridges to store nitrogen or carbon There are 11 types of discharge nozzles each designed to distrib- dioxide expellant gases under pressure until the system is actuat- ute the liquid agent in a uniform pattern throughout the hazard ed, at which time the cartridge seal is punctured and the released area: gas expels liquid agent from one or more tanks through the dis- 1. 1W Nozzle 7. 245 Nozzle charge piping and out the discharge nozzles. 2. 1N Nozzle 8. 260 Nozzle Four nitrogen gas cartridges and three carbon dioxide gas car- 3. 1 /2N Nozzle 9. 290 Nozzle tridges are available as shown in Figure 13. 4. 3N Nozzle 10. 2120 Nozzle Cartridges noted as TC /DOT are both Transport Canada (TC) and 5. 2W Nozzle 11. 1F Nozzle Department of Transportation (DOT) approved. Cartridges noted 6. 230 Nozzle as DOT are Department of Transportation approved only. Cartridge selection options are provided in Section IV under Tank Although these nozzles are similar in appearance and have and Cartridge Requirements. certain common parts, the tip of each nozzle is designed for a specific application and must only be used in those areas. See NITROGEN GAS CARTRIDGES Nozzle Application Chart in Section IV - System Design, for individual nozzle usage. 1 318 — 18 NPT 7 7/8 IN. FEMALE THREAD (20 cm) 11 3/8 IN. 10 1/2 IN. (28.9 cm) (27 cm) 14 5/8 IN. (37.1 cm) INTERNAL CUP 2 1/2 IN. STRAINER (6.4 cm) 2 1/2 IN. 4 3/161N. INSIDE (6.4 cm) (10.6 cm) RECESS FOR OFF 3 9/16 IN. CAP /�/�/�/� —/� VENDOR (9 cm) CODE LT -20 -R LT -30 -R DOUBLE -TANK LT-A-101-30 NOZZLE 1 (IF PRESENT) CARTRIDGE CARTRIDGE CARTRIDGE CARTRIDGE STAMPING I I PART NO. 423429 PART NO. 423435 PART NO. 423493 PART NO. 423491 (TC /DOT) (TC /DOT) (TC/DOT) ( TC/DOT) 000145 000149 000147 000149 FIGURE 14 000002 CARBON DIOXIDE CARTRIDGES Nozzle Identification Chart Nozzle Nozzle Nozzle Nozzle* Flow s IN 77/61N Type Part No. Stamping N. Nozzle Identification (22.9 cm) ( cm) 1W Nozzle 419336 1W 1 Chrome - Plated Body 11 5/8 IN. (29.5 cm) 1N Nozzle 419335 1N 1 Chrome - Plated Body - 4 1— "" 1/2N Nozzle 419334 1/2N 1/2 Chrome - Plated Body Metal blow -off caps are not allowed with the 1/2N nozzle 2 IN. 2 1/2 IN. (5.1 cm) (6.4 cm) I 3N Nozzle 419338 3N 3 Chrome - Plated Body 221 - 2W Nozzle 419337 2W 2 Chrome Plated Body (6.4 cm) . 230 Nozzle 419339 230 2 Chrome - Plated Body 101 -10 CARTRIDGE 101 -20 CARTRIDGE 101 -30 CARTRIDGE 245 Nozzle 419340 245 2 Chrome - Plated Body PART NO. 423439 (TC/DOT) PART NO. 423441 PART NO. 423443 PART NO. 15850 (DOT) (TC/DOT) ( TC/DOT) 260 Nozzle 419341 260 2 Chrome - Plated Body 000149 000150 000151 290 Nozzle 419342 290 2 Chrome - Plated Body FIGURE 13 2120 Nozzle 419343 2120 2 Chrome - Plated Body • Additional cartridge shipping assemblies are available for 1F Nozzle 419333 1F 1 Chrome - Plated Body European and Australian requirements. * Nozzle stamping may contain an additional letter indicating a vendor's code. Cartridge European Australian Description Part No.* Part No.* SILICONE LUBRICANT LT20 -R 428440 428948 Dow Corning Compound 111, Part No. 78112, is available in a LT-30R 428441 426553 5.3 -ounce tube. Compound has excellent qualities for sealing and Double Tank 428446 426563 lubricating system components. LT-A-101-30 428442 426555 101 -10 - CO2 428443 N/A 101 -20 - CO2 428445 N/A 101 -30 - CO2 428444 N/A • * Non -UL Listed SECTION III — SYSTEM COMPONENTS UL EX. 3470 ULC CEx747 Page 3 -8 REV.7 4 -1 -06 DETECTORS CLIP -ON STYLE - PART NO. 56837 AND 56838 The detector consists of three basic components: the bracket, link- age, and fusible link. (Fusible links are not included and must be ordered separately.) The bracket holds the entire assembly to the FusIeLE mounting surface. The linkage is used to support the fusible link. LINKAGE LINK BRACKET The fusible link is designed to separate at a specific temperature j" � j and release the wire rope, thereby actuating the regulated release .•l /`. mechanism. 000157 There are three styles of detectors available: the clip -on style, the HINGED STYLE - PART NO.15373 AND 15375 hinged style, and the scissor style. The clip -on style allows the wire rope to be strung completely through the detection system conduit and brackets first and the detector linkage assemblies are then clipped on later. LINKAGE FUSIBLE BRACKET The hinged style detector requires the wire rope to be strung to the , LINK detector bracket, and then "threaded" through the linkage assem- bly before continuing to the next detector bracket. The scissor style allows the wire rope to be strung completely 080158 through the detection system conduit and brackets first and the detector linkage assemblies are then clipped on later. SCISSOR STYLE - PART NO. 417368 AND 417369 Each style of detector consists of two types of assemblies: BRACKET The Terminal Detector (Part No. 56838, 15375, or 417368) LINKAGE o includes a test link and is placed last in a series of detectors. This detector is sometimes referred to as the end-of -line detector and A is thus named because it is at the point at which the wire rope "ter- FUSIBLE 14. minates," or is anchored at the detector bracket. Only one terminal LINK detector is required per detection system. The Series Detector (Part No. 56837, 15373, or 417369) is any . 00012 detector located in -line between the regulated release assembly FIGURE 22 and the terminal detector. PULLEY ELBOWS When using Part No. 56837 and 56838 style detectors, a total of There are two types of pulley elbows used to change the direction 12 detectors can be in one detection system: 11 series detectors, of the wire rope by 90 °. ANSUL recommends for temperatures not Part No. 56837 and 1 terminal detector, Part No. 56838. in excess of 700 °F (371 °C). Part No. 415670 has socket ends When using Part No. 15373 and 15375 style detectors, a total of 5 with set screws for 1/2 in. conduit, and Part No. 423250 has com- detectors can be in one detection system: 4 series detectors, Part pression ring ends also for 1/2 in. conduit. Pulley elbows must be No. 15373 and 1 terminal detector, Part No. 15375. ordered in quantities of 50 as Shipping Assembly Part No. 415671 When using Part No. 417368 and 417369 style detectors, a total (socket end type) and Part No. 423251 (compression end type). of 15 detectors can be in one detection system: 14 series detec- PART NO. 415670 PART NO. 423250 tors, Part No. 417369 and 1 terminal detector, Part No. 417368. 0 1 1 : 111 Goi AI _■ 000180 000181 FIGURE 23 SECTION III - SYSTEM COMPONENTS UL EX. 3470 ULC CEx747 Page 3 -9 4 -1 -06 REV.4 PULLEY TEE MECHANICAL GAS VALVES The Pulley Tee (Part No. 427929) is used to change the direction The mechanical gas valves are designed to shut off the flow of gas of two wire ropes by 90 °. It must be used in areas where the tem- to the appliances upon actuation of the regulated release assem- peratures are within the range of 32 °F to 130 °F (0 °C to 54 °C). bly.The valves are available in sizes of 3/4 in., 1 in., 1 1/4 in., 1 1/2 Pulley tees can be used in mechanical gas valve actuation lines in., and 2 in. ANSUL style; and 2 1/2 in. and 3 in. Asco style. The and remote manual pull station lines. Pulley tees cannot be used valves are rated for natural and LP gas. Both styles are UL Listed within a detection line. and includes the air cylinder, tubing, and fittings for connection to the release mechanism. r •I Maximum ( , ! e e II Part Operating No. Description Pressure 55598 3/4 in. Gas Valve (ANSUL) 10 psi (.69 bar) ,.' 55601 1 in. Gas Valve (ANSUL) 10 psi (.69 bar) 55604 1 1/4 in. Gas Valve (ANSUL) 10 psi (.69 bar) ' FIGURE 24 55607 1 1/2 in. Gas Valve (ANSUL) 10 psi (.69 bar) °0°4" 55610 2 in. Gas Valve (ANSUL) 10 psi (.69 bar) STAINLESS STEEL CABLE 25937 2 1/2 in. Gas Valve (ASCO) 5 psi (.35 bar) 25938 3 in. Gas Valve (ASCO) 5 psi (.35 bar) The 1/16 in. stainless steel cable is run from the terminal detector, through conduit, all series detectors and pulley elbows, and into A B C the regulated release mechanism trip lever. When any fusible link Valve Size in. (mm) in. (mm) in. (mm) separates, the tension on the cable is relaxed, and the trip lever 3/4 in. 3 3/4 (95.3) 6 3/8 (161.9) 5 1/2 (139.7) actuates the regulated release mechanism. The cable can also be 1 in. 3 3/4 (95.3) 6 3/8 (161.9) 5 1/2 (139.7) used for mechanical gas valves and remote manual pull stations. 1 1/4 in. 4 7/8 (123.8) 7 3/8 (187.3) 6 3/8 (161.9) The cable is available in 50 ft. (15 m) (Part No. 15821) and 500 ft. 1 1/2 in. 4 7/8 (123.8) 7 3/8 (187.3) 6 3/8 (161.9) (152.4 m) (Part No. 79653) lengths. 2 in. 5 7/8 (149.2) 7 7/8 (200.0) 6 11/16 (169.9) 2 1/2 in. 7 13/16 (198.4) - -- 9 1/16 (230.2) REMOTE MANUAL PULL STATION 3 in. 7 25/32 (197.6) -- 9 1/16 (230.2) The remote manual pull station (Part No. 4835 or Part No. 54011) IMI is required for manual actuation of the regulated release assembly. - ii i The remote manual pull station should be mounted at a point of egress and positioned at a height determined by the authority c ,. h Mil aving jurisdiction. Trim rings, Part No. 427074 (pack of 10), are _ available. ■ II PART NO. 4835 (WITHOUT CABLE) h . ' PART N0.54011 (WITH 50 FT. OF CABLE) v aa 111 ' • _NN (LL � p� B ' 1 k A —1 _ ?0 3/4 IN. THRU 2 IN. 2 1/2 IN. THRU 3 IN. �� ` 1 004208 004209 a FIGURE 26 METAL STAMPED 0001&9 FIGURE 25 SECTION I11— SYSTEM COMPONENTS • UL EX. 3470 ULC CEx747 Page 3 -11 4 -1 -06 REGULATOR TEST KIT HOSE/GROMMET PACKAGE The Test Kit Assembly (Shipping Part No. 56972) is required to test The Hose /Grommet Package, Part No.418511, consists of a 24 in. the regulator setting and nitrogen flow during 12 -year maintenance rubber hose and 2 (two) grommets. This package is required when examinations. This will ensure that the regulator is functioning mounting an AUTOMAN Regulated Release (or Regulated properly. Actuator) and a tank enclosure (or tank bracket) side by side in nn either a manifolded system or an independent piping system. �; ,/ ) , �11.I BURSTING DISC - ., The R-102 Bursting Disc is installed in the tank adaptor assembly. , ____&4,.. The bursting disc eliminates the siphoning of the agent up the pipe ��' . during extreme temperature variations. The bursting discs are ��, available in packs of 10, Part No. 417911. ► FIGURE 31 000169 FUSIBLE LINK Select correct UL Listed fusible link(s) for installation in detector(s) FIGURE 33 according to the temperature condition chart below: 006 K STYLE Fusible Link To Be Used NOZZLE AIMING DEVICE Fusible Shipping Where The Nozzle Aiming Device, Part No. 431992, is available to prop - Link Assembly Temperature Temperature erly aim each nozzle to the correct aiming point. The device Part No, Part No. Rating Does Not Exceed clamps to the nozzle and emits a small laser light that reflects on 415739 (1) 415739 (1) 165 °F (74 °C) 100 °F (38 °C) the surface that it is aiming at. The nozzle can then be rotated to 415740 (1) 415740 (1) 212 °F (100 °C) 150 °F (66 °C) point at a predetermined aiming point and then tightened to hold 415741 (1) 415744 (25) 280 °F (138 °C) 225 °F (107 °C) that angle. The aiming device adaptor attaches to the nozzle. The • 415742 (1) 415745 (25) 360 °F (182 °C) 290 °F (143 °C) shipping assembly consists of the aiming device and the adaptor. • 415743 (1) 415746 (25) 450 °F (232 °C) 360 °F (182 °C) . ML STYLE Fusible Link To Be Used Fusible Shipping Where c ` R Link Assembly Temperature Temperature ■ \ Part No. Part No. Rating Does Not Exceed ADAPTOR 550368 (1) 551522 (10) 165 °F (74 °C) 100 °F (38 °C) NOZZLE 1 550365 (1) 551523 (10) 212 °F (100 °C) 150 °F (66 °C) AIMING Il 550366 (1) 551524 (10) 280 °F (138 °C) 225 °F (107 °C) • DEVICE FIGURE 34 • 550009 (1) 551525 (10) 360 °F (182 °C) 290 °F (143 °C) 006520 550367 (1) 551526 (10) 450 °F (232 °C) 360 °F (182 °C) STAINLESS STEEL ACTUATION HOSE 56816 (1) 551527 (10) 500 °F (260 °C) 400 °F (204 °C) • ► 56816 (1) 73867 (25) 500 °F (260 °C) 400 °F (204 °C) The Stainless Steel Actuation Hose is used to connect the actua- tion line compression tees between each pneumatic actuator. The hose has the same thread, 7/16 -20, as the fittings. The actuation O G O hose allows flexibility between the AUTOMAN and each regulated actuator. . Hose Part No. Length ( Couplings --7 31809 16 in. 41 cm) 7/16-20 x 7/16 -20 Females f=iLl 4 a; ,. a, TEMPERATURE I RATING STAMPED ON 32335 20 in. (51 cm) 7/16 -20 x 7/16 -20 Females La ® FUSIBLE LINK BODY 32336 24 in. (61 cm) 7/16 -20 x 7/16 -20 Females • 430815 42 in. (107 cm) 7/16 -20 Female x 1/4 in. NPT a Fitting Part No. Description KSTYLE ML STYLE 31810 Male Elbow (7/16 -20 x 1/4 in. NPT) FIGURE 32 ■ 31811 Male Tee (7/16 -20 x 7/16 -20 x 1/4 in. NPT) 415371 Tee (7/16 -20 x 1/8 in. Male NPT x 1/8 in. Female NPT) MAXIMUM REGISTERING THERMOMETER 32338 Male Straight Connector (7/16 -20 x 1/4 in. NPT) • 25627 1/4 in. Check Valve The Maximum Registering Thermometer, Part No. 15240, is used to indicate the highest normal temperature for the protected area. ��� � . � ,�, - 4.4. :� fa Once this is established, the correct rated fusible link can be �I : ; •.,?. �s.�'.��� chosen. �' I Ila 7/16-20 7/16-20 ► FIGURE 35 000433