Permit li-; ,; CITY OF TIGARD FIRE PROTECTION SYSTEM PERMIT I ` �; COMMUNITY DEVELOPMENT Permit #: FPS2009 -00110 , Date Issued: 11/20/2009 TIGARD)' 13125 SW Hall Blvd., Tigard OR 97223 503.639.4171 Parcel: 2S112DD01601 Jurisdiction: Tigard Site address: 15755 SW SEQUOIA PKWY 100 Subdivision: Lot: 0 Project: Bridgeport MRI Project Description: Add (2) pendent sprinklers and relocate (1) pendent sprinkler Owner: FEES PACIFIC REALTY ASSOCIATES Description Date Amount 15350 SW SEQUOIA PKWY #300 Permit Fee - COM 11/20/2009 $56.47 PORTLAND, OR 97224 12% State Surcharge - Building 11/20/2009 $6.78 PHONE: 503 - 624 -6300 Contractor: WESTERN STATES FIRE PROTECTION 13896 FIR ST STE B OREGON CITY, OR 97045 PHONE: 503 - 657 -5155 FAX: 503 - 657 -5182 Type of Use: COM Class of Work: ALT Type of Const: VB Occupancy Grp: B Height: ft Stories: Commercial Sprinkler System: Sprinkler Required: Yes Sprinkler Type: Wet Standpipe Required: No Hazard: LT Density: Design Area: K Factor: Commercial Fire Alarm System: Fire Alarm Required: Alarm Type: Pull Station Required: Smoke Detectors Req: Battery Calcs Provided: Cut Sheets Required: Total $63.25 Valuations: Required Items and Reports (Conditions) Sprinkler Valuation: 650.00 Residential Square Footage: Fire Alarm Valuation: This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952 - 001 -0010 through OAR 952 - 001 -0100. You may obtain a copy of the rules or direct questions to OUNC by calling 503.246.6699 or 1.800.332.2344. / Issued By: % � I� Permittee Signature: �N � p G �C�/ �O N /( Call 503.639.4175 by 7:00 a.m. for an inspection that business day. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. Building Permit Application II. Ern cLA \ Fire Protection System RECEIVED FOR OFFICE USE ONLY City of Tigard Date /B Received , . ` , amid /, 'ermit No. II q S :7, D ©//D 13125 SW Hall Blvd., Tigard, OR 97223 NOV 19 2009 Plan Review Phone: 503.639.4171 Fax: 503.598.1960 DateB : Other Permi ` -� /, - - # i T I GAR D Inspection Line: 503,639.4175 Date Ready /By: ES ® See Page 2 for Internet: www.tigard - or.gov CITY OF TIGARD Notified/Method: Supplemental Information BUILDING DIVISION • TYPE OF WORK REQUIRED DATA: 1- AND 2- FAMILY DWELLING ❑ New construction ❑ Demolition Permit fees* are based on the value of the work performed. Indicate the value (rounded to the nearest dollar) of all ® Addition/alteration/replacement ❑ Other: equipment, materials, labor, overhead, and the profit for the CATEGORY OF CONSTRUCTION work indicated on this application. Valuation: $ ❑ 1- and 2- family dwelling ® Commercial /industrial ❑ Accessory building ❑ Multi- family Number of bedrooms: ❑ Master builder ❑ Other: Number of bathrooms: JOB SITE INFORMATION AND LOCATION Total number of floors: Job site address: 15755 SW Sequoia Pkwy New dwelling area: square feet City /State /ZIP: Tigard, OR 97224 Garage /carport area: square feet Suite/bldg. /apt. no.: 1 00 Project name: Bridgeport aging in QZ Covered porch area: square feet Cross street/directions to job site: Deck area: square feet Other structure area: square feet REQUIRED DATA: COMMERCIAL -USE CHECKLIST Subdivision: Lot no.: Permit fees* are based on the value of the work performed. Tax map /parcel no.: Indicate the value (rounded to the nearest dollar) of all equipment, materials, labor, overhead, and the profit for the DESCRIPTION OF WORK work indicated on this application. add two (2) pendent sprinklers & relocate one (1) pendent sprinkler Valuation: $$650.00 Existing building area: square feet New building area: square feet ❑ PROPERTY OWNER ❑ TENANT Number of stories: Name: Type of construction: Address: Occupancy groups: City /State /ZIP: Existing: Phone: ( ) Fax: ( ) New: ® APPLICANT ® CONTACT PERSON NOTICE Business name: Western States Fire Protection Co. All contractors and subcontractors are required to be Contact name: Darrell Fluit licensed with the Oregon Construction Contractors Board under ORS 701 and may be required to be licensed in the Address: 13896 Fir Street, Suite B jurisdiction in which work is being performed. If the City /State /ZIP: Oregon City, OR 97045 applicant is exempt from licensing, the following reasons apply: Phone: (503) 657 -5155 Fax: : (503) 657-5182 E -mail: darrell.fluit @wsfp.us CONTRACTOR BUILDING PERMIT FEES* Business name: Western States Fire Protection Co. (Please refer ta fee schedule, Permit fee: 5 , 9/7 Address: 13896 Fir Street, Suite B State surcharge (12% of permit fee): 6, 78 City /State /ZIP: Oregon City, OR 97045 0 FLS plan review (40% of permit fee): 0 / . , . Phone: (503) 657 -5155 Fax: (503) 657 -5182 (Due upon application.) �.� = CCB lic.: 104570 Total permit fees: . t?1/41'r Amount received: ,.k.5', SI Authorized signature: This permit application expires if a permit is not obtained Print name: Darrell Fluit Date: 11 - 19 - 09 within 180 days after it has been accepted as complete. * Fee methodology set by Tri- County Building Industry Service Board. 6g, ,g5 I\Buildin \FPS - PermitApp.doc 10 /01/09 440- 4613T(I I /02 /COM/WEB) City of Tigard: Fire Protection Permit Checklist Page 2 - Supplemental Information Describe work to be done: _ 1.) ❑ New 2.) Modification to sprinkler heads only: ❑ Addition ® 1 -10 heads: No plan review required. ® Alteration ❑ 11+ heads: Plan review required. El Repair Number of sprinkler heads: 3 Additional description of work: Type of System (Complete A, B, C or D as applicable): _ A.) Commercial Sprinkler ® Wet El Dry Additional Standpipes Information: Hazard Group Density Design Area K. Factor Sprinkler Project Valuation: $ B.) Type I - Hood Fire Suppression System Hood Project Valuation: $ C.) Fire Alarm Submittal shall Battery Calculations ❑ Yes include: Individual Component El Yes Cut Sheets Fire Alarm Project Valuation: $ D.) Residential Sprinkler (Stand Alone System) Square Footage: Permit Fee: 0 to 2,000 $198.75 2,001 to 3,600 $246.45 3,601 to 7,200 $310.05 7,201 and greater $404.39 Sprinkler Project Square Footage: sq. ft. Fire Protection Permit Fees Project valuation subtotal (see A, B & C above): $ Permit fee based on project valuation (see fee schedule): $ Permit fee based on square footage (see D above): $ State Surcharge (12% of permit fee): $ FLS Plan Review (40% of permit fee): $ TOTAL: $ Plan review requires a completed application and 2 sets of plans at submittal. Plan review fees are required at submittal. C: \Documents and Settings \ loraine \Local Settings \Tl'cmnporary Internet Files \Content.CtEtlook \L3XK1T611 \City of Tigard Building permit app.doc 10/01/09 ADD 1• '40 — ADD ST • OR * 103 RELOCATE 0-* WAITING/ RECEPTION 102 X-RAY RECEIVED 04 NOV 1 9 2009 ITY OF TIGARD AREA OF Kt* N LDING DIVISION CITY „OF TIGARD Approved ......... - ; Conditionally Approved.......... See Letter to Follow •....,.... j Attacled I „ Permit Number: ejr0 0 1 55 it) S 4 Ple-467 Date: TENANT IMPROVEMENT RELOCATE ONE (1)EXISTING SPRINKLERS FOR TI BRIDGEPORT IMAGING TI ADD TWO (2) SPRINKLERS FOR TI 15755 SW SEQUOIA PKWY TIGARD, OREGON Western States Fire L O S Protection Companv 13896 Fir St Suite B Oregon City, OR 97045 AUTOMATIC SPRINKLER SYSTEMS / SPECIAL HAZARDS SYSTEMS Coficato of Rotostrabon 104570 JDoesbigNnoer.: DARRELL FLUIT 1262 Date NOVEMBER 18, 2009 lo PHONE NO (503)657.5155 FAX NO (503)-657-5182 Seale: 1 /4“ = 1'-0 OFFICE COPY •° --- - -- .L.12•:(3. ,,z ' . • - ••••••-• 7 'e -- , ----'. - --- -- - ---- - .. - - -, ' ,.. Reader D' Adobe Reader .= arwork bridgeport IM!fil3WSFP,(44.pdfd IA '- 0 - "- - - - - .; :- • - ' - .. • .;--,-- --' -: - ., - &' • ,... --'-- •.-- , -s':;::- (a , • ; - 'Li tgil a File Edit View Document Tools Window Help - SI X . - .1. C Save „l . .., f l-, i D. Select ii . ._..) , : — - fTh I ..,.-I Create an 4 ae a Copy . 1---- P, 0 Search ri .-. i + + e 12 00% 1- 0 , a ,----, • : (6 Help v - Inn I - , -.+_.4 —i t '14 Adobe PDF online L__ r4 1 . U Li Li 1 i ■ i 0 A 1 CO * $ ee 0. 1 -- ,... , V — 1 t-, ___----,..' - r - I ----1 1 .......,......T i ,..,. \ °-",/ „c„,7 a-r,........,Arm ...E2 . .... , -- t r=z-zo, • _ / ._ - -- - Ili II A [. — R ' . ':', , , 4 `.....- it 4-. , ,,,-- -,--,--....,.....--._. -----J ----, , ,......... ' Or, 15 - .....- . i . . ..'"•* . - ., D 1 * .,) ,...,.....-..,....--,...., 4 , • .•--,, ' . ....... . . 1 ,11. -",,,,, -,cit•r.,••,„„, t • I'd . 'k ,, pi . 4- 1,0 4 - • ----- rz: . .15 1 ..k- -4 __, __,„!____ — - .1. o It I itz T "E 0 .) E = c.) 03 L(.6 i E 0,4 III n 1 t. Ill 1 i ' 1 14 1 i ' . i '- 1 i . • , ,..., i , .... , e 111111W 27„.' -' " l' .0-- .....--- ............. -0 ''.... I <1) tel E _ E o c.) _ 41■ 1 8.50 x 11.00in < l > 0 lz:1-- , 1 . ow,,k„.....0.,•oft,...„,,,,,,„ ,,,ti ,.., andgepor, g.2.0 , NCOCtiti)'TiguserkLise ' ,,,Eit„Adobe e P' ie 402b - ' -.,` ,,.... ' _ 4 tr4 1 I 7 2 4 '..d.-.,s-C-;,,,Z,-s.,,.;',...._,-,4 ,-..."7-...-,...;,.......1,:::. :, — ' ' ''''. ::.-•..- ; ;,,,,,.:' —,.,;.... *i'..... ...,,: : ':- • ‘ - 4, ''' . , ,., ',.': ,.-.,..` Bulletin 136 Rev.M Model F1 FR CO ® Model F1 FR Recessed D ' w; Quick Response co , co 0, Y y Sprinklers . Jo K Model F1 FR Sprinkler Ty • pY/y 9 ��/ /1t 1pf! Standard Uprigh . Standard Pendent; "'' ,_ as Conventional NOV 19 2009 ., a'! Vertical Sidewall ` CITY OF TIGARD , `. � t s ;' Horizontal Sidewall BUILDING DIVISION '' `. - HSW 1 Deflector t' ' °� ° Model F1 FR Recessed Sprinkler Types:" Recessed Pendent Upright Pendent Recessed Horizontal Sidewall - HSW 1 Deflector Listings & Approvals + ig 1. Listed by Underwriters Laboratories, Inc. (UL) 2. Listed by Underwriters' Laboratories of Canada (ULC) 1' 14 1 3. Certified by FM Approvals - , '', 4. Loss Prevention Council (LPC, UK) 5. NYC BS &A No. 587 -75 -SA 6. Meets MILS 901C and MIL STD 167-1 7. Verband der Schadenversicherer (VdS, Germany) , , ., 8. NYC MEA 258 -93 -E UL Listing Category Vertical Sidewall Conventional Sprinklers, Automatic & Open Quick Response Sprinkler UL Guide Number VNIV °° 4.• - A 7 : f i,ZN d t sQ Patents: US Patent No. 6,374,920 Applies to Model F1 FR Vertical Sidewall Sprinklers. . � -- Product Description Horizontal Sidewall Recessed Pendent Reliable Models F1FR and F1FR Recessed Sprinklers are HSW 1 Deflector (Model FP Shown) I quick response sprinklers which combine the durability of a standard sprinkler with the attractive low profile of a decorative sprinkler. pands, forcing the bubble smaller and smaller as the liquid The Models F1FR and F1FR Recessed automatic sprinklers pressure increases. Continued heating forces the liqui t or utilize a 3.0 mm frangible glass bulb. These sprinklers have push out against the bulb, causing the glass tot shatter, demonstrated response times in laboratory tests which are opening the waterway and allowing the deflector to distrib- five to ten times faster than standard response sprinklers. This ute the discharging water. quick response enables the Model F1FR and F1FR Recessed sprinklers to apply water to a fire much faster than standard Appl sprinklers of the same temperature rating. Quick response sprinklers are used in fixed fire protec- The glass bulb consists of an accurately controlled amount tion systems: Wet, Dry, Deluge or Preaction. Care must be of special fluid hermetically sealed inside a precisely manu- exercised that the orifice size, temperature rating, deflector factured glass capsule. This glass bulb is specially con- style and sprinkler type are in accordance with the latest structed to provide fast thermal response. The balance of published standards of the National Fire Protection Asso- parts are made of brass, copper and beryllium nickel. ciation or the approving Authority Having Jurisdiction. At normal temperatures, the glass bulb contains the fluid Quick response sprinklers are intended for installation as in both the liquid and vapor phases. The vapor phase can specified in NFPA 13. Quick response sprinklers and stan- be seen as a small bubble. As heat is applied, the liquid ex- dard response sprinklers should not be intermixed. The Reliable Automatic Sprinkler Co., Inc. 525 North MacQuesten Parkway, Mount Vernon, New York 10552 .., - Model Fl FR Quick Response Upright, Pendent & Conventional Sprinklers • Installation Wrench: Model D Sprinkler Wrench Installation Data: ii Sprinkler Type K Factor Sprinkler identification rinkler Approv al Standard—Upright (SSU) and Pendent (SSP) Sp Number (SIN) Deflectors Marked to Indicate Position US Metric Height Organization SSU 1 SSP 2. (15mm) Standard Orifice with 22" NPT (R) Thread 5.6 80 2.2" (56mm) 1,2,3,45,6,7 R3625 R3615 " (20mm) Large Orifice with 9/ NPT (R3/4)Thread 8.0 115 2.3" (58mm) 1,2,3,4,7,8 R3622 R3612 (17mm) Small Orifice with / NPT (R,) Thread 4.2 60 2.2" (56mm) 1,2,8 R3623 R3613 " (10mm) Small Orifice with y NPT (R 2) Thread 2.8 40 2.2" (56mm) 1,2,8 R3621 R3611 10mm Orifice XLH with R Thread 4.2 60 56mm 4,6,7 R3624 R3614 Conventional-Install in Upright or Pendent Position lOmm Orifice XLH with R Thread 4.2 60 56mm R3674 15mm Standard Orifice with ,v NPT (RY Thread 5.6 80 56mm 4,6,7 R3675 20mm Large Orifice with 3 /4 " NPT (R3/4)Thread 8.0 115 , 58mm 4,7 R3672 .......--...,, „ " >•' , ---7- , — ,[[''': ' [,.• 'A -0 ei I ,,, ,, , ', ' , y,_....„ 4,1 .-:•-.■ , ..,{" , t Z. k Upright Pendent Conventional Model Fl FR Quick Response Recessed Pendent Sprinkler 1 Installation Wrench: Model GFR1 Sprinkler Wrench Installation Data: Factor Nominal Thread K Fac Sprinkler Approval Sprinkler Identification Orifice Size US Metric Height Organizations Number (SIN) 2/ (15mm) / NPT (R 5.6 80 2.2" (56mm) 1,2,3,4,5,7,8 R3615 Y32 Y NPT (R3/4) 8.0 115 2.3" (58mm) 1,2,3,8 R3612 • j, (11mm) }" NPT (R1/2) 4.2 60 2.2" (56mm) 1,2,8 R3613 " (10mm) Y," NPT (R1/2) 2.8 40 2.2' (56mm) 1,2,8 I R3611 10mm R I 4.2 60 56mm 4,7 1 R3614 (1) Refer to escutcheon data table for approvals and dimensions. 2 5/8" 024 1 —1.- 2 L,Ar HOLE DIA 11020 IN CEILING 1,..._ ,i _..... —. 2 5/16' DIA. [58 7^5rni ...- CUP iiq , - 1 1/2 REDUCER 1 -- ,• . 1 /2" REDUCT 6' TuPov COLLAR 1IN772 to rr -r ACAINST SPRINKLER WRENCH 13055 — 1 —1 \ \ 1 / ,__„ -_ J _ ADJUS • , ' • Fp " r i CLOW; ruI5PON CFI' IILT: --\ amrillIlatra I „ / co'. va n i i 03 Vd _„__ _ Ir mu. 11 FACE OF FITTING , II■ TO FACF OF (Ell INC i 1 n ‘,,‘„ i. , 1 0124085108,,,, I [.52mm] Ay , I rg■ " n ,..,„ 2 27/32' DIA ADJUSTMENT • , _ [777q66[ ---"."- !MI-CALF t IJE ; (I) REM TO F & F2 ESCUTCHEON DATA TABLE FOR APPROVALS AND OWEN5/095 (I) REFER TO rP ESCUTCHEON DATA TAOLE FOR APPROVAL5 AND DIMENSIONS 2. • Model F1FR Quick Response Vertical Sidewall Sprinkler Installation Wrench: Model D Sprinkler Wrench Installation Position: Upright or Pendent Approval Type: Light Hazard Occupancy Installation Data: Nominal Thread K Factor Sprinkler Approval Sprinkler identification Orifice Size US Metric Height Organizations Nu mbber er (SIN) Number Y2" 1/2" NPT (RY /) 5.6 80 2.2" (56mm) 1, 2, 3, 6, 8 _ _ --- ....._ . ._.._.. ___ ........ _.._.... R3685 15mm Y" NPT (R1/2) 5.6 80 2.2" (56mm) 4 (1) (1) LPC Approval is for Pendent position only. Orientation Deflector to Ceiling -•- Dimension (Min. - Max.) " ' Upright 4" - 12" (102mm - 305mm) s 1, ^, Pendent 6 12" (152mm - 305mm) 0 Vertical Sidewall US Patent No. 6,374,920 Model F1FR Quick Response Horizontal Sidewall Sprinkler Deflector: HSW 1 Installation Wrench: Model D Sprinkler Wrench • Installation Data: Approval Organizations K Factor and Type of Approval Sprinkler • Nominal Thread Sprinkler Identification Orifice Size US Metric Length Light Ordinary Number (SIN) Hazard Hazard / (15mm) y" NPT(R1/2) 5.6 80 2 63" (67mm) 1,2,3,5,8 1,2,5,8 R3635 NOTE: UL, ULC and MEA Listing permits use with F1 or F2 recessed escutcheon. 725r604 %// / ,' / 4 (7) r4cE Or FIrr1NS r0 � - � WAII. DIMENSION 1 1/4' MIN, 4 ,,,i '�� - 2 7 jn ' oLE DIA. .--..- (5' mm [3. [101 5rrrm 52.4mrrt, } } F #{ � C" L - CEILING ;0 '�; r3 i s i 7' REDOK_R DEFT rr TOR 1h, 7 15/16' DIA. 1 / i : {{ Horizontal Sidewall l l i ��.� _i� 2 2 D /A. „ ry 1 / 7?. 2,177] L i ,,,,iii, L TURN COLLAR UN 1,1 - � Y TIGHT AGAINST SPRINKLER WRENCH 8055 (7) �ADJUI ML NI (7) REFER 70 f..SCU1HeEON DA IA 7A131_ E FOR APPROVAL 5 AND OMENS10N5. 3. Installation Quick response sprinklers are intended for installation as cleaning fluids. Remove dust by using a soft brush or gen- . specified in NFPA 13. Quick response sprinklers and stan- tle vacuuming. Remove any sprinkler which has been dard response sprinklers should not be intermixed. painted (other than factory applied) or damaged in any The Model F1FR Recessed Quick Response Sprinklers are to way. A stock of spare sprinklers should be maintained to be installed as shown. The Model F1 or F2 Escutcheons illus- allow quick replacement of damaged or operated sprin- trated are the only recessed escutcheons to be used with the klers. Prior to installation, sprinklers should be maintained Model F1 FR Sprinklers. The use of any other recessed escutch- in the original cartons and packaging until used to mini - eon will void all approvals and negate all warranties. mize the potential for damage to sprinklers that would When installing Model F1FR Sprinklers, use the Model D Sprin- cause improper operation or non - operation. kler Wrench. When installing Model F1FR Recessed Pendent or Sidewall Sprinklers, use the Model GFR1 Sprinkler Wrench. Any Sprinkler Types other type of wrench may damage these sprinklers. Standard Upright Glass bulb sprinklers have orange bulb protectors to minimize Standard Pendent bulb damage during shipping, handling and installation. RE- MOVE THIS PROTECTION AT THE TIME THE SPRINKLER Conventional SYSTEM IS PLACED IN SERVICE FOR FIRE PROTECTION. Re- Sidewall (Vertical, Horizontal HSW1) moval of the protectors before this time may leave the bulb vul- Recessed Pendent nerable to damage. RASCO wrenches are designed to install Recessed Horizontal Sidewall HSW1 sprinklers when covers are in place. REMOVE PROTECTORS BY UNDOING THE CLASP BY HAND. DO NOT USE TOOLS Finishes (1) (2) TO REMOVE THE PROTECTORS. Standard Finishes Temperature Ratings Sprinkler Escutcheon Bronze Brass Sprinkler ( Chrome Plated Chrome Plated (3) Max. Ambient Bulb Classification Temperature Temp. Color White Polyester Coated White Painted (3) °C °F Ordinary 57 135 100°F (38°C) Orange Special Application Finishes Ordinary 68 155 100 °F (38 °C) Red Sprinkler Escutcheon Intermediate 79 175 150 °F (66 °C) Yellow Bright Brass Bright Brass Intermediate 93 200 150 °F(66°C) Green Black Plated Black Plated High (1) 141 286 225 °F(107 °C) Blue Black Paint Black Paint (1) Not available for recessed sprinklers. Off White Off White Escutcheon Data Satin Chrome Satin Chrome . Face of Fitting I ( Other finishes and colors are available on special order. Escutcheon Approvals p Adjusbnerd toCelpngor Consult the factory for details. Dimension model Wall Dimension (2) FM Approvals is limited to bronze and brass, chrome or black 1X" plated finishes only. • F1 1,2,4,8 Max Recess (38.1mm) /t6 "-15/6 ( FP Push - on/Thread -off escutcheon Min Recess X " (5mm - 24mm) (19.1mm) Ordering Information 1y Specify: F2 1,2,3,4,5,7,8 Max Recess (38.1mm) 6" 'Ys Min Recess 1 / 6 " (5mm -17mm) 1. Sprinkler Model (24mm) 2. Sprinkler Type 1,2 Max Recessed /,6 (11mm) " 1A" (38.1mm) 3. Orifice Size FP Push -on/ • � 4. Deflector Type Thread-off 1,2 Min Recessed 1' (254m) (24mm) _._..._ m 5. Temperature Rating No Dimensional Figure for FP 6. Sprinkler Finish 7. Escutcheon Type Maintenance 8. Escutcheon Finish (where applicable) The Models F1FR and F1FR Recessed Sprinklers should be inspected quarterly and the sprinkler system Note: When Model F1FR Recessed sprinklers are maintained in accordance with NFPA 25. Do not clean ordered, the sprinklers and escutcheons are packaged sprinklers with soap and water, ammonia or any other separately. The equipment presented in this bulletin is to be installed in accordance with the latest pertinent Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 80 years, and are installed and serviced by the most highly qualified and reputa- ble sprinkler contractors located throughout the United States, Canada and foreign countries. Manufactured by The Reliable Automatic Sprinkler Co., Inc. R Pape . , T ,. I ellabl : . , ',. (800)431 -1588 Sales Offices (800)848 Sales Fax Revision lines indicate updated or new data (914)668 -3470 Corporate Offices www.reliablesprinkler.com Internet Address EG. Primed in U.S.A. 7/05 P/N9999970027