Permit CITY OF TIGARD - FIRE PROTECTION SYSTEM PERMIT q IS ' � COMMUNITY DEVELOPMENT Permit #: FPS2009 -00109 T [GAR D 13125 SW Hall Blvd., Tigard OR 97223 503.639.4171 Date Issued: 11/19/2009 Parcel: 2S 101 DA00101 Jurisdiction: Tigard Site address: 13190 SW 68TH PKWY 110 Subdivision: TRIANGLE CORPORATE PARK Lot: 3 Project: Business Objects Project Description: Relocate (5) sprinkler heads. Owner: FEES PACIFIC NW PROPERTIES LIMITED PA Description Date Amount STERN FAMILY LIMITED PARTNERSHIP &, Permit Fee - COM 11/19/2009 $61.85 STERN, HELEN R REV TRUST, 6600 SW 105TH 12% State Surcharge Building 11/19/2009 $7.42 PHONE: Contractor: AFP SYSTEMS INC 19435 SW 129TH TUALATIN, OR 97062 PHONE: 503 - 692 -9284 FAX: 503 - 692 -1186 Type of Use: COM Class of Work: ALT Type of Const: Occupancy Grp: Height: ft Stories: Commercial Sprinkler System: Sprinkler Required: Sprinkler Type: Standpipe Required: Hazard: Density: Design Area: K Factor: Commercial Fire Alarm System: Fire Alarm Required: Alarm Type: Pull Station Required: Smoke Detectors Req: Battery Calcs Provided: Cut Sheets Required: Total $69.27 Valuations: Required Items and Reports (Conditions) Sprinkler Valuation: 900 Residential Square Footage: Fire Alarm Valuation: This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notif - • -r. Those rules are set forth in OAR 952 - 001 -0010 through OAR 952 - 001 -0100. You may obtain a copy of the rules or dir- • questions to OU by • 'ng 503.246.6699 or 1.800.332.2344. Is ued By: ,- 1 / r Permittee Signature: , a / Call 503.639.4175 by 7:00 a.m. for an inspection that business day. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. Building Permit Application 1i - DO 90 e • Fire Protection System FOR orrlcE USE aN LV . • R ECEIV City of Tigard E Recened �� Permit s 0 � • y Davy: / 9 a id e9e 9 - aD o i l l q 13125 SW hall Blvd "Tigard, Olt 97223 NOV 19 2009 Plan Review 1 Phone: 503.639.4171 Fax: 503.598.1960 Date/By: Other Permit: Re 1 I CiARI) Inspection line: 503.639 4175 / �� D a DIViSi t Kcadyfliy: See Page 2 for Internet: wR'tf.tlgard•or.gov V n' GF TiGARD Notified/Method: ad Supplemental )nformelion BUI LDING _ - TYPE OF WORK, - REQUIRED DA'L'A :1- AND 2- FAMILYDWELLING ❑ New construction ❑ Demolition -- Penni( fees* are bawd on the value of the work performed. — Indicate the value (rounded to the nearest dollar) of all Addition /alteration/replacement ❑ Other: equipment, materials, labor, overhead, and the profit for the CATEGORY OF CONSTRUCTION work indicated on this application. ❑ 1 • and 2-family dwelling g&ommercial /in(lustrial Vahlatiai: S ❑ Accessory building ❑ Multi- tinily Number of bedrooms: ❑ Master builder ❑ Other: Number of bathrooms: /3/_917 JOl) SI`l'F. INFORMATION AND LOCATION' 4 _ total number of floors: Job site address_ ±-=) W ( L 5 rn Fwd ■Ai `:;-'1 New dwelling area: square feet City /State /ZIP: t ,., c„,,1.1 or u ` Garage /carport arca_ square feet Suite/bldg. /apt. no.: / 10 I Project name: - - -_ Po u , Covered porch area: square feet Cross street/directions to job site: Deck area: square feet Other structure arca: square feet REQUIRED 1)A'TA: COMMERCIAL -USE, CIIE:CKLdST Subdivision: - -1 Lot no.: Permit fees* are based on the value of the work performed. fax map /parcel no.: Indicate the value (rounded to the nearest dollar) of all equipment, materials, labor, overhead, and the profit for the DFSCRI1'1'1ON OF WORK - work indicated on this application. ; :a)- ]_ 0 G Valuation: S �(�O }- _ Existing building area: `I �;�;) square feet `, L�\nM — New building arca: )00y square feet 5r PROI'EitTY OWNER ❑ 'TENANT Number of stories: Name: f j ' v P "1 ie of construction: — Address: Occupancy groups: City /State / /IP: -- -- — _ —„ J Existing_ Phone: ( ) Fax: ( ) New: APPI ICANT ❑ C:ONIACI' PERSON : NOTIC Business nani( A Fe - Al} contractors and subcontractors are required to be i licensed with the Oregon Construction Contractors Board 3 w Contact name: , V _ under ORS 701 and may be required to be licensed in the Address: 1 4 7 �� ' c - 4J t . jurisdiction in which work is being performed. lithe City /Slate /ZIP: -i- ,L ,JAI o f� - applicant is exempt from licensing, the following reasons apply: Phone: ( S t / 5 ) 6 ° 1 2 41 t 1 Fax:: (L 3) i,, 9 z -1 ( t, i, E -mail: ,t't - Q . ' ._ Of Sys. cclM • - CONTRACTOR . BUiL DIN(:1'ERMI'1' FEES* Business name: S �iy G.; tt, __- - - - - - (f'lease,ejer to fee schedule Permit fee: 6/. F Address: - - State surcharge (12% of permit fee): 7 , i/A City /Slate /7.11': FLS plan review (40% of permit fee): �^ Phone: ( ) Fax: ( ) - (Due upon application) - Total permit fees: * X / 9.4....._ Amount received: Authorized S1g11ahlrC This permit application expires if a permit Is not obtained Print nannc: _ 1 within 180 days after it leas been accepted as complete. r yt.� •,- '� llatc: + Fee methodology set by 7'ri- County Building Industry ` ` _._..... _ Service Board. r: 9(oi!dingll'enni I s\IlS•1'eimitAprdoc 03/23/06 410.16131(11/07C0>V\4C11) City of Tigard: Fire Protection Permit Checklist Page 2 - Supplemental information Describe work to be done: 1.) 111 New 2.) Modification to sprinkler heads only: 0 Addition F-1-10 heads: No plan review required. 44_ Alteration El 11+ heads: Plan review required. 0 Repair Number of sprinkler heads: - 3 Additional description of work: p a A cti A L T )e of S stem Com tete A, B, C orD as a licable : A.) Commercial Sprinkler BC \Vet fl . E)ry _ Additional Standpipes n fo rmation: Hazard Group Li 6 ,4.1- Density ' Design Area I 5 00 K. Factor Sprinkler Project Valuation: $ B.) Type 1 - Hood Firc Suppression System Hood Project Valuation: $ C,) Fire Alarm Submittal shall Battery Calculations 0 Yes include: Individual Component 111 Yes Cut Sheets Fire Alarm Project Valuation: $ D.) Residential Sprinkler (Stand Alone System) Square l'ootage: Permit Fee: 0 to 2,000 $187.50 2,001 to 3,600 $232.50 3,601 to 7,200 $292.50 7,201 and greater $381.50 Sprinkler Project Square Footage: sq. ft. Fire Protection Permit Fees Project valuation subtotal (see A, 13 & C above): $ Permit fee based on project valuation (see fcc schedule): $ Permit fcc based on square footage (see D above): $ State Surcharge (12% of permit fcc): $ Fl.,S Plan Review (40% of permit fcc): $ TOTAL: $ Ilan review requires a completed application and 2 sets of plans at submittal. Plan review fees are requited at subrnittal. I: \ Building\ Pennits \ I^PS-PermitApp.doc 0025/08 2 tqco I Fire & Buiiding Products Technical Services: Tel: (800) 381 -9312 / Fax: (800) 791 -5500 Series TY -FRB — 2.8, 4.2, 4.6' and 8.0 K- factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage tained when exposed to corrosive at- G eneral mospheres. Although corrosion resis- Via_ -,, tant coated sprinklers have passed the � "_ - Description standard corrosion tests of the appli- '.- • �: cable approval agencies, the testing is - , -, The Tyco® Series TY -FRB, 2.8, 4.2, not representative of all possible cor- � 5.6, and 8.0 K- factor, Upright and Pen- rosive atmospheres. Consequently, it 1 tililLik d dent Sprinklers described in this data is recommended that the end user be i iltri f sheet are quick response - standard consulted with respect to the suitability coverage, decorative 3 mm glass bulb of these coatings for any given corro- • h type spray sprinklers designed for use sive environment. The effects of ambi- %,..- in light or ordinary hazard, commercial ent temperature, concentration of — -=- Y chemicals, and gas /chemical velocity, occupancies such as banks, hotels, — ""_ p shopping malls, etc. should be considered, as a minimum, The recessed version of the Series along with the corrosive nature of the TY -FRB Pendent Sprinkler, where ap- chemical to which the sprinklers will be �� r �,Sb Gc G, plicable, is intended for use in areas exposed. , with a finished ceiling. It uses either a An intermediate level versions of the ':,..,---4, - k C.7 c",, two -piece Style 10 (1/2 inch NPT) or Series TY -FRB Pendent Sprinklers - 1 - Style 40 (3/4 inch NPT) Recessed Es- are detailed in Technical Data Sheet , cutcheon with 1/2 inch (12,7 mm) of TFP356, and Sprinkler Guards are de- I ; <---- recessed adjustment or up to 3/4 inch tailed in Technical Data Sheet TFP780 (19,1 mm) of total adjustment from the - . f ,fi" flush pendent position, or a two -piece WARNINGS e. re 7 Style 20 (1/2 inch NPT) or Style 30 (3/4 The Series TY -FRB Sprinklers de- �,. inch NPT) Recessed Escutcheon with scribed herein must be installed and --4"_: " 1/4 inch (6,4 mm) of recessed adjust- maintained in compliance with this • ment or up to 1/2 inch (12,7 mm) of document, as well as with the applica- total adjustment from the flush pen- ble standards of the National Fire Pro - dent position. The adjustment pro- tection Association, in addition to the vided by the Recessed Escutcheon re- standards of any other authorities hav- Model/Sprinkler duces the accuracy to which the fixed ing jurisdiction. Failure to do so may pipe drops to the sprinklers must be impair the performance of these de- Identification cut. vices. Corrosion resistant coatings, where The owner is responsible for maintain- Numbers applicable, are utilized to extend the ing their fire protection system and de- life of copper alloy sprinklers beyond vices in proper operating condition. TY1131 - Upright 2.8K, 1/2 "NPT that which would otherwise be ob- The installing contractor or sprinkler TY1231 - Pendent 2.8K, 1/2 "NPT manufacturer should be contacted TY2131 - Upright 4.2K, 1/2 "NPT with any questions. TY2231 - Pendent 4.2K, 1/2 "NPT IMPORTANT TY3131 - Upright 5.6K, 1/2 "NPT Always refer to Technical Data TY3231 - Pendent 5.6K, 1/2 "NPT Sheet TFP700 for the 'INSTALLER TY4131 - Upright 8.0K, 3/4 "NPT WARNING" that provides cautions TY4231 - Pendent 8.0K, 3/4 "NPT with respect to handling and instal- TY4831- Upright 8.0K, 1/2 "NPT lation of sprinkler systems and com- TY4931- Pendent 8.0K, 1/2 "NPT ponents. Improper handling and in- stallation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 10 AUGUST, 2007 TFP171 Page 2 of 10 TFP171 ESCUTCHEON 7/16" (11,1 mm) STYLE' 1 or 20 PLATE SEATING NOMINAL RECESSED SURFACE 1/2" T MAKE-IN ESCUTCHEON DEFLECTOR 6 �= fir i - 1 - 1 - 1 :,Trr�,ITtr E ; �f 5 2 -114" 7/16„ f (11,1 mm) I 4 (57,2 mm) - - I NOMINAL I I 1 MAKE -IN � 2 1 -9/16" r_r �" "A I (556/mm) J' V 3 (39,7 mm) WRENCH :� ill jr. t ill Air /%1!ti \\ FLATS f 41golif 1 SSP DEFLECTOR 2 -7/8" (73,0 mm) DIA. - 1/2" NPT PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression 7 - Bushing orifice seat on frame. Screw FIGURE 1 QUICK RESPONSE SERIES TY -FRB UPRIGHT (TY1131) AND PENDENT (TY1231) SPRINKLERS 2.8 K- FACTOR, 1/2 INCH NPT ESCUTCHEON 7/16" (11,1 mm) STYLE 10 or 20 PLATE SEATING NOMINAL RECESSED SURFACE NP MAKE-IN ESCUTCHEON DEFLECTOR 6 i ..--.. h i �'r 7/16" 5 2- 3/16" m� } MI- (11,1 mm) i (55,6 mm) . = � �� - I NOMINAMAKE -IN L ' 4 7� 1 -1/2" r� 2- 3/16" �o 2 (38,1 mm) I ill WRENCH (55,6 mm) V 'o. . FLATS 3 I i 1 SSP DEFLECTOR - 2 -7/8" (73,0 mm) DIA. 1/2" NPT i PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression orifice seat on frame. Screw FIGURE 2 QUICK RESPONSE SERIES TY -FRB UPRIGHT (TY2131) AND PENDENT (TY2231) SPRINKLERS 4.2 K- FACTOR, 1/2 /NCH NPT TFP171 Page 3 of 10 ESCUTCHEON 7/16" (11,1 mm) STYLE 10 or 20 PLATE SEATING NOMINAL RECESSED SURFACE 1/2 MAKE-IN ESCUTCHEON DEFLECTOR NPT 6 r 7/16" !ter 5 2- 3/16 " ( 11,1 mm) (55,6 mm) ��� N OMINAL I (38,1 /2" I I ! 2-3/16" . .!D 2 (55,6 mm) 111 - - • FLATS — _ 3 1 SSP DEFLECTOR* f— 2 -7/8" (73,0 mm) DIA. - 1/2" NPT PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression orifice seat on frame. Screw FIGURE 3 QUICK RESPONSE SERIES TY -FRB UPRIGHT (TY3131) AND PENDENT (TY3231) SPRINKLERS 5.6 K- FACTOR, 1/2 INCH NPT ESCUTCHEON 1/2" (12,7 mm) STYLE 30 or 40 PLATE SEATING NOMINAL RECESSED SURFACE \ NPT MAKE -IN ESCUTCHEON DEFLECTOR 6 t — ..........— _ 1/2.. Ins 5 � 2- 5/16" } If : (12,7 mm) (58,7 mm) I�O NOMINAL i I 4 � 1-9/16" r= 014 MAKE -IN 2 -1/4" u'2 (39,7 mm) I Ir L�- WRENCH (57,2 mm) IVI 9 �'r 3 • III -- • FLATS I 7 SSP DEFLECTOR - 2 -7/8" (73,0 mm) DIA. 3/4" NPT f PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression orifice seat on frame. Screw FIGURE 4 QUICK RESPONSE SERIES TY -FRB UPRIGHT (TY4131) AND PENDENT (TY4231) SPRINKLERS 8.0 K- FACTOR, 3/4 INCH NPT Page 4 of 10 TFP171 •7116" (11,1 rnm) 1/2" NOMINAL SSU NPT MAKE -IN DEFLECTOR 1=5; 5 2 -1/4" } 2- 3/16" (57,2 mm) 0 = , 1 I (55,6 mm) ; 4 1-9/16" WRENCH r�r V 2 (39,7 mm) FLATS I -- -- 3 SSP DEFLECTOR CROSS PENDENT UPRIGHT SECTION 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression orifice seat on frame. Screw FIGURE 5 QUICK RESPONSE SERIES TY -FRB UPRIGHT (TY4831) AND PENDENT (TY4931) SPRINKLERS 8.0 K- FACTOR, 1/2 INCH NPT Technical Operation Data The glass Bulb contains a fluid which expands when exposed to heat. When Approvals the rated temperature is reached, the UL and C -UL Listed. fluid expands sufficiently to shatter the FM, LPCB, and NYC Approved. glass Bulb, allowing the sprinkler to (Refer to Table A and B for complete activate and water to flow. approval information including corro- sion resistant status.) Design Maximum Working Pressure Refer to Table C. Criteria Discharge Coefficient K = 2.8 GPM /psi / (40,3 LPM /bar1 /2) The Series TY -FRB Pendent and Up- K = 4.2 GPM /psi / (60,5 LPM /bar1 /2) right Sprinklers are intended for fire K = 5.6 GPM /psi / (80,6 LPM /bar1/2) protection systems designed in ac- K = 8.0 GPM /psil/ (115,2 LPM /bar1/2) cordance with the standard installation rules recognized by the applicable Temperature Ratings Listing or Approval agency (e.g., UL Refer to Table A and B Listing is based on the requirements of Finishes NFPA 13, and FM Approval is based Sprinkler: Refer to Table A and B. on the requirements of FM's Loss Pre - Recessed Escutcheon: White Coated, vention Data Sheets ). Only the Style Chrome Plated, or Brass Plated. 10, 20, 30, or 40 Recessed Escutch- eon, as applicable, is to be used for recessed pendent installations. Physical Characteristics c Frame Bronze E Button Brass /Copper 0 Sealing Assembly Beryllium Nickel w /Teflont Bulb Glass a) a � Compression Screw Bronze m Deflector Copper /Bronze 0 Bushing (K =2.8) Bronze '2 a in 4— TFP171 Page 5 of 10 SPRINKLER FINISH (See Note 7) K TYPE TEMP. BULB NATURAL CHROME WHITE*** LIQUID BRASS PLATED POLYESTER 135 °F /57 °C Orange PENDENT 155 °F /68 °C Red (TY1231) ) 175 °F /79 °C Yellow 1, 2, 3, 5 UPRIGHT 200F/93°C Green 2.8 (TY1131) 286 °F /141 °C Blue 1/2" NPT 135 °F /57 °C Orange RECESSED 155 °F /68 °C Red PENDENT (TY1231)* 175F/79°C Yellow Figure 6 200 °F /93 °C Green 1, 2, 5 135 °F /57 °C Orange RECESSED 155 °F /68 °C Red PENDENT (TY1231) ** 175 °F /79 °C Yellow Figure 7 200F/93°C Green 135 °F /57 °C Orange PENDENT 155 °F /68 °C Red (TY2231) and 175 °F /79 °C Yellow UPRIGHT 200F/93°C Green 4.2 (TY2131) 286 °F /141 °C Blue 1 2 1/2" NPT 135 °F /57 °C Orange RECESSED 155 °F /68 °C Red PENDENT (TY2231)* 175F/79°C Yellow Figure 8 200 °F /93 °C Green 135 °F /57 °C Orange RECESSED 155F/68°C Red PENDENT (TY2231) ** 175F/79°C Yellow Figure 9 20OF/93°C Green NOTES: 1. Listed by Underwriters Laboratories, Inc. (UL) as Quick Response Sprinklers. 2. Listed by Underwriters Laboratories, Inc. for use in Canada (C -UL) as Quick Re- sponse Sprinklers. 3. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprin- klers. 5. Approved by the City of New York under MEA 354 -01 -E. 7. Where Polyester Coated Sprinklers are noted to be UL and C -UL Listed, the sprin- klers are UL and C -UL Listed as Corrosion Resistant Sprinklers. * Installed with Style 10 (1/2" NPT) or Style 40 (3/4" NPT) 3/4" Total Adjustment Recessed Escutcheon, as applicable. ** Installed with Style 20 (1/2" NPT) or Style 30 (3/4" NPT) 1/2" Total Adjustment Recessed Escutcheon, as applicable. * ** Frame and Deflector only. Listings and approvals apply to color (Special Order). N /A: Not Available TABLE A LABORATORY LISTINGS AND APPROVALS 2.8 AND 4.2 K- FACTOR SPRINKLERS Page 6 of 10 TFP171 SPRINKLER FINISH (See Note 8) K TYPE TEMP. BULB NATURAL CHROME WHITE*** LEAD LIQUID BRASS PLATED POLYESTER COATED 135 °F /57 °C Orange PENDENT 155 °F /68 °C Red (TY3231) 1, 2, 3, 4, 5, 6, 7 1, 2, 3, 5 and 175 °F /79 °C Yellow UPRIGHT 200F/93°C Green 5.6 (TY3131) 286F/141°C Blue 1/2" NPT 135 °F /57 °C Orange RECESSED 155 °F /68 °C Red PENDENT 1, 2, 4, 5 N/A (TY3231)* 175 °F /79 °C Yellow Figure 10 200 °F /93 °C Green 135F/57°C Orange RECESSED 155 °F /68 °C Red PENDENT 1, 2, 3, 4, 5 N/A (TY3231) ** 175 °F /79 °C Yellow Figure 11 200 °F /93 °C Green 135F/57°C Orange PENDENT 155F/68°C Red (TY4231) 1, 2, 5 and 175 °F /79 °C Yellow 1, 2, 3, 4, 5, 6, 7 UPRIGHT 200 °F /93 °C Green 8.0 (TY4131) 286F/141°C Blue 3/4" NPT 135F/57°C Green RECESSED 155F/68°C Orange PENDENT 1, 2, 4, 5 N/A (TY4231)* 175 °F /79 °C Red Figure 12 200 °F /93 °C Yellow 135 °F /57 °C Orange RECESSED 155 °F /68 °C Red PENDENT 1, 2, 3, 4, 5 N/A (TY4231) ** 175 °F /79 °C Yellow Figure 13 200F/93°C Green 135 °F /57 °C Orange PENDENT 155 °F /68 °C Red TY4931 1/2" ( /2" and 175 °F /79 °C Yellow 1, 2, 4, 5, 6 1, 2, 5 NPT UPRIGHT 200F/93°C Green (TY4831) 286 °F /141 °C Blue NOTES: 1. Listed by Underwriters Laboratories, Inc. (UL) as Quick Response Sprinklers. 2. Listed by Underwriters Laboratories, Inc. for use in Canada (C -UL) as Quick Response Sprinklers. 3. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers. 4. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 007k/04) as Quick Response Sprinklers; however, the LPCB does not rate the thermal sensitivity of recessed sprinklers. 5. Approved by the City of New York under MEA 354 -01 -E. 6. VdS Approved (For details contact Tyco Fire & Building Products, Enschede, Netherlands, Tel. 31- 53- 428- 4444/Fax 31 -53- 428 - 3377). 7. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/06) as Quick Response Sprinklers. 8. Where Polyester Coated and Lead Coated Sprinklers are noted to be UL and C -UL Listed, the sprinklers are UL and C -UL Listed as Corrosion Resistant Sprinklers. Where Lead Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as a Corrosion Resistant Sprinklers. * Installed with Style 10 (1/2" NPT) or Style 40 (3/4" NPT) 3/4" Total Adjustment Recessed Escutcheon, as applicable. ** Installed with Style 20 (1/2" NPT) or Style 30 (3/4" NPT) 1/2" Total Adjustment Recessed Escutcheon, as applicable. * ** Frame and Deflector only. Listings and approvals apply to color (Special Order). N /A: Not Available TABLE B LABORATORY LISTINGS AND APPROVALS 5.6 AND 8.0 K- FACTOR SPRINKLERS TFP171 Page 7 of 10 • SPRINKLER FINISH K TYPE NATURAL CHROME WHITE LEAD BRASS PLATED POLYESTER COATED PENDENT (TY3231) and 2.8 UPRIGHT (TY3131) 175 PSI (12,1 BAR) N/A 1/2" RECESSED PENDENT NPT (TY323) PENDENT (TY4231) and 4.2 UPRIGHT (TY4131) 175 PSI (12,1 BAR) N/A 3/4" RECESSED PENDENT NPT (TY4231) PENDENT (TY3231) and 250 PSI (17,2 BAR) 175 PSI (12,1 BAR) 5.6 UPRIGHT(TY3131) OR 1/2" RECESSED PENDENT 175 PSI (12,1 BAR) NPT (TY3231) (SEE NOTE 1) N/A PENDENT (TY4231) and 175 PSI (12,1 BAR) 175 PSI (12,1 BAR) 8.0 UPRIGHT (TY4131) 3/4" RECESSED PENDENT NPT (TY4231) N/A 8.0 PENDENT(TY4931) 1/2" and 175 PSI (12,1 BAR) 175 PSI (12,1 BAR) NPT UPRIGHT (TY4831) NOTES: 1. The maximum working pressure of 250 psi (17,2 bar) only applies to the Listing by Underwriters Laboratories Inc. (UL); the Listing by Underwriters Laboratories, Inc. for use in Canada (C -UL); and , the Approval by the City of New York. TABLE C, MAXIMUM WORKING PRESSURE tained with a torque of 10 to 20 ft.lbs. the sprinkler into the sprinkler fitting. Installation (13,4 to 26,8 Nm). A maximum of 30 ft.lbs. (40,7 Nm) of torque is to be used Step 3. Tighten the sprinkler into the The Series TY -FRB Sprinklers must to install sprinklers with 3/4 NPT con- sprinkler fitting using only the W -Type be installed in accordance with the fol- nections. Higher levels of torque may 6 Sprinkler Wrench (Ref. Figure 14). lowing instructions: distort the sprinkler inlet and cause With reference to Figures 1, 2, 3, 4, leakage or impairment of the sprinkler. and 5, the W-Type 6 Sprinkler Wrench NOTES is to be applied to the sprinkler wrench Do not install any bulb type sprinkler if Do not attempt to make -up for insuffi- flats. the bulb is cracked or there is a loss of cient adjustment in the escutcheon The Series TY -FRB Recessed Pen - liquid from the bulb. With the sprinkler plate by under- or over - tightening the dent Sprinklers must be installed in held horizontally, a small air bubble sprinkler. Readjust the position of the accordance with the following instruc- should be present. The diameter of the sprinkler fitting to suit. tions. air bubble is approximately 1/16 inch The Series TY -FRB Pendent and Up- Step A. After installing the Style 10. (1,6 mm) for the 135 °F /57 °C to 3/32 right Sprinklers must be installed in 20, 30, or 40 Mounting Plate, as appli- inch (2,4 mm) for the 286 °F /141 °C accordance with the following instruc- cable, over the sprinkler threads and temperature ratings. tions. with pipe thread sealant applied to the A leak tight 1/2 inch NPT sprinkler joint Step 1. Pendent sprinklers are to be pipe threads, hand tighten the sprin should be obtained with a torque of 7 installed in the pendent position, and kler into the sprinkler fitting. to 14 ft.lbs. (9,5 to 19,0 Nm). A maxi- upright sprinklers are to be installed in Step B. Tighten the sprinkler into the mum of 21 . ft. lbs. (28,5 Nm) of torque the upright position. sprinkler fitting using only the W -Type may be used to install sprinklers with Step 2. With pipe t sealant ap- 7 Recessed Sprinkler Wrench (Ref. ep e 1/2 NPT connections. A leak tight 3/4 St ht Figure 15). With reference to Figure 1, inch NPT sprinkler joint should be ob- plied 2 the pipe a th ea, hand tighten 2, 3, and 4, the W -Type 7 Recessed Page 8 of 10 TFP171 2 -7/8" DIA. . 2 -7/8" DIA. 5/8 ±1/4" (73,0 mm) 3/4" (19,1 mm) (73,0 mm) 1/2" (12,7 mm) (15,9 ±6,4 mm) 2.1/4" DIA. 1/4" (6,4 mm) (12,7 ±3,2 mm) 2 -1/4" DIA. 1/4" (6,4 mm) FACE OF (57,2 mm) MOUNTING FACE OF (57,2 mm) MOUNTING SPRINKLER PLATE SPRINKLER PLATE FITTING FITTING 1/8" 1/8" �� ' (3,2 mm) i •!'i (3,2 mm) 11-l lfli �-* • s . f MOUNTING VIP MOUNTING . SURFACE � . SURFACE iil• /f.1l�� CLOSURE SERIES 1-5/16" (33,3 mm) CLOSURE SERIES 1- 5/16" (33,3 mm) TY -FRB 13/16" (20,6 mm) TY -FRB 1- 1/16" (27,0 mm) FIGURE 6 FIGURE 7 SERIES TY -FRB RECESSED PENDENT SERIES TY -FRB RECESSED PENDENT WITH TWO -PIECE 3/4 INCH TOTAL ADJUSTMENT WITH TWO -PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON STYLE 20 RECESSED ESCUTCHEON 2.8 K- FACTOR, 1/2 INCH NPT 2.8 K- FACTOR, 1/2 INCH NPT 2 -7/8" DIA. 2 -7/8" DIA. 5/8 ±1/4" (73,0 mm) 3/4" (19,1 mm) 1/2 ±1/8" (73,0 mm) 1/2" (12,7 mm) (15,9 ±6,4 mm) 2 -1/4" DIA. 1/4" (6,4 mm) (12,7 ±3,2 mm) 2 -1/4" DIA. 1/4" (6,4 mm) FACE OF (57,2 mm) MOUNTING FACE OF (57,2 mm) MOUNTING SPRINKLER PLATE SPRINKLER PLATE FITTING FITTING 1/8" •�' (3,2 mm) •� ' (3,2 mm) • i ----------,--- 1 iM MrAl X _ r_ r _i_ ' \ � f MOUNTING �:' MOUNTING SURFACE •. . -• CLOSURE SERIES 1 -1/4" (31,8 mm) CLOSURE SERIES 1 -1/4" (31,8 mm) TY-FRB 3/4" (19,1 mm) TY -FRB 1" (25,4 mm) FIGURE 8 FIGURE 9 SERIES TY -FRB RECESSED PENDENT SERIES TY -FRB RECESSED PENDENT WITH TWO -PIECE 3/4 INCH TOTAL ADJUSTMENT WITH TWO -PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON STYLE 20 RECESSED ESCUTCHEON 4.2 K- FACTOR, 1/2 INCH NPT 4.2 K- FACTOR, 1/2 INCH NPT Sprinkler Wrench is to be applied to work on the fire protection system that altered after leaving the factory. Modi- the sprinkler wrench flats. it controls, permission to shut down the fied sprinklers must be replaced. affected fire protection system must be Sprinklers that have been exposed to Step C. After the ceiling has been in- stalled or the finish coat has been ap- obtained from the proper authorities corrosive products of combustion, but plied, slide on the Style 10, 20, 30, or and all personnel who maybe affected have not operated, should be replaced 40 Closure over the Series TY -FRB by th action must be notified if they cannot be completely cleaned Sprinkler and push the Closure over The owner must assure that the sprin- by wiping the sprinkler with a cloth or the Mounting Plate until its flange klers are not used for hanging of any by brushing it with a soft bristle brush. comes in contact with the ceiling. objects; otherwise, non - operation in Care must be exercised to avoid dam - the event of fire or inadvertent opera- age to the sprinklers - before, during, Care and tion may result. and after installation. Sprinklers dam - Absence of an escutcheon, which is aged by dropping, striking, wrench Maint enance to cover a clearance hole, may twist/slippage, or the like, must be re- 1a®ntenance placed. Also, replace any sprinkler delay the time to sprinkler operation in that has a cracked bulb or that has lost The Series TY -FRB Sprinklers must a fire situation. liquid from its bulb. (Ref. Installation be maintained and serviced in accord- Sprinklers that are found to be leaking Section). ance with the following instructions: or exhibiting visible signs of corrosion must be replaced. Frequent visual inspections are rec NOTES ommended to be initially performed for Before closing a fire protection system Automatic sprinklers must never be corrosion resistant coated sprinklers, main control valve for maintenance painted, plated, coated or otherwise after the installation has been com- TFP171 Page 9 of 10 2 -7/8" DIA. . DIA - 5/8 ±1/4" (73,0 mm) 3/4" (19,1 mm) 1/2±1/8" (73,0 mm) 1/2" (12,7 mm) (15,9 ±6,4 mm) 2 -1/4" DIA. y 1/4" (6,4 mm) (12,7 ±3,2 mm) 2 -1/4" DIA. y 1/4" (6,4 mm) FACE OF (57,2 mm) MOUNTING FACE OF (57 mm) MOUNTING SPRINKLER PLATE SPRINKLER PLATE FITTING FITTING 1/8" 1/8" IT (3,2 mm) �� (3,2 mm) rr , ii ria f � � \ 1 IP MOUNTING _ MOU SURFACE SURFACE - ' ' 1 - CLOSURE SERIES 1 -1/4" (31,8 mm) CLOSURE SERIES 1 -1/4" (31,8 mm) TY -FRB 3/4" (19,1 mm) TY-FRB 1" (25,4 mm) FIGURE 10 FIGURE 11 SERIES TY -FRB RECESSED PENDENT SERIES TY -FRB RECESSED PENDENT WITH TWO -PIECE 3/4 INCH TOTAL ADJUSTMENT WITH TWO -PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON STYLE 20 RECESSED ESCUTCHEON 5.6 K- FACTOR, 1/2 INCH NPT 5.6 K- FACTOR, 1/2 INCH NPT 2 -7/8" DIA. _ 2-7/8" DIA. - 5/8±1/4" (73,0 mm) 3/4" (19,1 mm) 1/2 ±1/8" (73,0 mm) 1/2" (12,7 mm) (15,9±6,4 mm) 2 -1/4" DIA. 1/4" (6,4 mm) (12,7 ±3,2 mm) F 2 -1/4" DIA. 1/4" (6,4 mm) (57,2 mm) MOUNTING FACE OF (57,2 mm) FACE OF MOUNTING SPRINKLER PLATE SPRINKLER PLATE FITTING FITTING 1/8" 1/8" r�Il (3,2 mm) i Eli ��. 3,2 1 \ AI �� U ,�, 1 MOUNTING �I� MOUNTING SURFACE SURFACE . ' CLOSURE SERIES 1 -5/16" (33,3 mm) CLOSURE SERIES 1- 5/16" (33,3 mm) TY -FRB 13/16" (20,6 mm) TY -FRB 1 -1/16" (27,0 mm) FIGURE 12 FIGURE 13 SERIES TY -FRB RECESSED PENDENT SERIES TY -FRB RECESSED PENDENT WITH TWO -PIECE 3/4 INCH TOTAL ADJUSTMENT WITH TWO -PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON STYLE 30 RECESSED ESCUTCHEON 8.0 K- FACTOR, 3/4 INCH NPT 8.0 K- FACTOR, 3/4 INCH NPT pleted, to verify the integrity of the cor- WRENCH rosion resistant coating. Thereafter, RECESS annual inspections per NFPA 25 / should suffice; however, instead of in- WRENCH RECESS specting from the floor level, a random (END "A" USED FOR sampling of close -up visual inspec- 1/2 " NPT MODELS) tions should be made, so as to better determine the exact sprinkler condi- tion and the long term integrity of the wo , corrosion resistant coatin as it ma WRENCH RECESS g ' y (END "8" USED FOR PUSH WRENCH be affected by the corrosive conditions 3 /4" NPT MODELS) IN TO ENSURE present. ENGAGEMENT The owner is responsible for the in- FIGURE 14 WITH SPRINKLER p WRENCHING AREA spection, testing, and maintenance of W -TYPE 6 SPRINKLER their fire protection system and de- WRENCH FIGURE 15 vices in compliance with this docu- W -TYPE 7 RECESSED ment, as well as with the applicable facturer should be contacted relative SPRINKLER WRENCH standards of the National Fire Protec- to any questions. tion Association (e.g., NFPA 25), in Inspection Service in accordance with addition to the standards of any other It is recommended that automatic local requirements and /or national authorities having jurisdiction. The in- sprinkler systems be inspected, codes. stalling contractor or sprinkler manu- tested, and maintained by a qualified Page 10 of 10 TFP171 P/N 57- XXX -X -XXX TEMPERATURE MODEL/SIN RATING SPRINKLER 330 2.8K UPRIGHT (1/2 "NPT) TY1131 135 135 °F /57 °C 331 2.8K PENDENT (1/2 "NPT) TY1231 1 NATURAL BRASS 155 155 °F /68 °C 340 4.2K UPRIGHT (1/2 "NPT) TY2131 4 WHITE POLYESTER 175 175F/79°C 341 4.2K PENDENT (1/2 "NPT) TY2231 3 WHITE (RAL9010)* 200 200 °F /93 °C 370 5.6K UPRIGHT (1/2 "NPT) TY3131 9 CHROME PLATED 286 286 °F /141 °C 371 5.6K PENDENT (1/2 "NPT) TY3231 7 LEAD COATED 390 8.0K UPRIGHT (3/4 "NPT) TY4131 391 8.0K PENDENT (3/4 "NPT) TY4231 * Eastern Hemisphere sales only. 360 8.0K UPRIGHT (1/2 "NPT) TY4831' 361 8.0K PENDENT (1/2 "NPT) TY4931* TABLE D PART NUMBER SELECTION SERIES TY -FRB PENDENT AND UPRIGHT SPRINKLERS LimitLimit no event shall TFBP be liable, in ed contract, tort, strict liability or under Ordering any other legal theory, for incidental, Warranty indirect, special or consequential dam- Procedure ages, including but not limited to labor Products manufactured by Tyco Fire & charges, regardless of whether TFBP When placing an order, indicate the Building Products (TFBP) are war- was informed about the possibility of full product name. Refer to the Price ranted solely to the original Buyer for such damages, and in no event shall List for complete listing of Part Num- ten (10) years against defects in mate- TFBP's liability exceed an amount bers. rial and workmanship when paid for equal to the sales price. Contact your local distributor for avail - and properly installed and maintained under normal use and service. This The foregoing warranty is made in lieu ability. warranty will expire ten (10) years of any and all other warranties. ex- from date of shipment by TFBP. No press or implied. including warranties Sprinkler Assemblies with NPT warranty is given for products or com- of merchantability and fitness for a par- Thread Connections: ponents manufactured by companies ticular purpose. Specify: (Specify Model /SIN), Quick Response, (specify K- factor), (specify not affiliated by ownership with TFBP This limited warranty sets forth the ex- temperature rating), Series TY -FRB or for products and components which clusive remedy for claims based on (specify Pendent or Upright) Sprinkler have been subject to misuse, improper failure of or defect in products, materi- with (specify type of finish or coating), installation, corrosion, or which have als or components, whether the claim P/N (specify from Table D). not been installed, maintained, modi- is made in contract, tort, strict liability fied or repaired in accordance with ap- or any other legal theory. Recessed Escutcheon: plicable Standards of the National Fire eci , , Re Protection Association, and /or the erm by y ' This warranty will apply to the full ex- S P fY Style Y ( 10 20, 30 or 40 ) tent permitted b law. The invalidity, in cessed Escutcheon with (specify *) fin - standards of any other Authorities p whole or p art, of an y portion of this Having Jurisdiction. Materials found s ish, P/N (specify*). by TFBP to be defective shall be either warranty will not affect the remainder. repaired or replaced, at TFBP's sole * Refer to Technical Data Sheet TFP770. option. TFBP neither assumes, nor Sprinkler Wrench: authorizes any person to assume for it, Specify: W -Type 6 Sprinkler Wrench, any other obligation in connection with P/N 56- 000 -6 -387. the sale of products or parts of prod- ucts. TFBP shall not be responsible for Specify: W -Type 7 Sprinkler Wrench, sprinkler system design errors or inac- P/N 56- 850 -4 -001. curate or incomplete information sup- plied by Buyer or Buyer's repre- sentatives. TYCO FIRE & BUILDING PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446