Permit II f P5 Building Division g TIGARD Check List � Over - The - Counter (OTC) Building Permit °rte 6A Description of Project: 17 _ GENERAL INFORMATION Class of Work:* L Floor Areas (sq. ft.): Exterior Wall Construction: Type of Use:* First floor: N: S: Type of Construction: Second floor: E: W: Occupancy Group: Third floor: Openings Protected Y /N ?: Occupancy Load: '-- Total sq ft.: N: S: Stories: Note: Combine total floor area E: E: for Height: _ all floors above third floor and Roof Construction: Floor Load: add to the third floor sq. ft. Fire Retardant: Basement: Basement: Area Separation Rated: Mezzanine: Garage: Occu. Separation Rated: REQUIRED ITEMS Fire sprinkler: YCs Handicap access: kl ) Smoke detector: Protected corridors: Fire alarm: 6 Parking spaces ( #): Notes: Total Valuation: $ 7 5 + CO INSPECTIONS FEES DUE Footing /foundation Firewall $ '(7, 70 Permit Fee Post /beam structural Smoke detector $ ( IC , ( State Surcharge Shear wall Misc. inspection $ G . ) Plan Review Fee Masonry Approach /sidewalk $ 1 - 7 ; C FLS Plan Review Fee Framing $ Additional Permit Fee Insulation Sprinkler rough -in $ Additional Plan Review Fee Gyp board Fire alarm $ Metro Construction Excise Tax Suspended ceiling Sprinkler final $ School Construction Excise Tax Final inspection $ Misc. Fee $ Hourly Rate Fee $ Hourly Rate State Surcharge $ Other: $ (9q ( , 4 Total Fees Due ''OPTIONS: TYPE OF USE: COM = commercial; CMS = commercial manufactured structure. CLASS OF WORK: ACS = accessory; ADD = addition; ALT = alteration; FND = foundation; DEM = demo; FND = foundation; FPS = fire protection system; NEW = new; OTR = other (use for fences, decks, retaining walls, signs, awnings or canopies); REP = repair. I: \Building\Forms \OTC - BUP.doc 08/19/08 qd CITY OF TIGARD FIRE PROTECTION SYSTEM PERMIT NI COMMUNITY DEVELOPMENT Permit #: FPS2009-00105 k Date Issued: 10/30/2009 TIGARD 13125 SW Hall Blvd., Tigard OR 97223 503.639.4171 Parcel: 2S112DD01400 Jurisdiction: Tigard Site address: 15686 SW SEQUOIA PKWY Subdivision: Lot: 0 Project: Courtyard By Marriott Project Description: Install (5) new fire sprinkler heads. Owner: FEES PACIFIC REALTY ASSOCIATES Description Date Amount PO BOX 58990 SEATTLE, WA 98138 Permit Fee - COM 10/30/2009 $64.54 12% State Surcharge - Building 10/30/2009 $7.74 PHONE: Contractor: SIMPLEXGRINNELL LP 6305 SW ROSEWOOD ST. LAKE OSWEGO, OR 97035 PHONE: 503 - 683 -9000 FAX. 503 - 675 -6521 Type of Use: COM Class of Work: ALT Type of Const: Occupancy Grp: Height: ft Stories: Commercial Sprinkler System: Sprinkler Required: Sprinkler Type: Standpipe Required: Hazard: Density. Design Area: K Factor: Commercial Fire Alarm System: Fire Alarm Required: Alarm Type: Pull Station Required: Smoke Detectors Req: Battery Calcs Provided: Cut Sheets Required: Total $72.28 Valuations: Required Items and Reports (Conditions) Sprinkler Valuation: 950 Residential Square Footage: Fire Alarm Valuation: This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility otification Cen = . Those rules are set forth in OAR 952 - 001 -0010 through OAR 952 - 001 -0100 .1 may obtain a copy of the rules or di ct questions to OU • • . -fling 503.246.6699 or 1.800.332.2344. _ i Is ued By: / f Permitte • Signature: �Ijp/ _ ,1. .0 .J . e tritom CaII 503.639.4175 by 7:00 a.m. for an inspection that b : mess day. This permit card shall be kept in a conspicuous place on the job s' - until completion of the project. Approved plans are required on the job site at the time of each inspection. Building Permit Application Fire Protection System FOR OFFICE USE ONLY ¢� '� Received III q City of Tigard q � Date /B : ed . , O Q 9 A Permit No.: ,� rte.„ 000/46S 13125 SW Hall Blvd., Tigard, OR 972 r� , Plan Review Phone: 503.639.4171 Fax: 503.598.1160 Date /B : Other Permit: Inspection Line: 503.639.4175 (, ^'" "� %fl ' Date Ready /By: luris: El See Page 2 for T I GARD G v O N otified /Method: Supplemental Information Internet: www.tigard- or.gov PP TYPE OF T;OARL1 'NG DIVISION REQUIRED DATA: 1- AND 2- FAMILY DWELLING ❑ New construction ❑ Demolition Permit fees* are based on the value of the work performed. Indicate the value (rounded to the nearest dollar) of all 2 /alteration/replacement ❑ Other: equipment, materials, labor, overhead, and the profit for the CATEGORY OF CONSTRUCTION work indicated on this application. Valuation: $ ❑ 1- and 2- family dwelling Commercial /industrial ❑ Accessory building 0 Multi- family Number of bedrooms: ❑ Master builder ❑ Other: Number of bathrooms: 154018 4 JOB SITE INFORMATION AND LOCATION Total number of floors: Job site address: .� " � t , W . ertu.G�Gi PG2 ,ekL New dwelling area: square feet 5 City /State /ZIP: T 4 , 6AI 97 -Z q Garage /carport area: square feet Suite/bldg. /apt. no.: d Project name: mitigiiemazirro►I.„ Covered porch area: square feet Cross street /directions to job site: I_ f _,� eek area: square feet i Other structure area: square feet REQUIRED DATA: COMMERCIAL -USE CHECKLIST Subdivision: Lot no.: Permit fees* are based on the value of the work performed. Tax map /parcel no.: Indicate the value (rounded to the nearest dollar) of all equipment, materials, labor, overhead, and the profit for the • DESCRIPTION OF WORK work indicated on this anplication. Valuation: If 9s 0 `` I / _TtiAttal ..c pre-6J S,icL .k' 0Ars 1 tki...5 fC 1 LIA S,t.lipt f r �A) . <47/FY S `� Existing building area: square feet U0 Lf New building area: square feet i q 93 ❑ PROPERTY OWNER ❑ TENANT Number of stories: Name: Type of construction: Address: Occupancy groups: 41,1/4 Ko atArol City /State /ZIP: Existing: Phone: ( ) Fax: ( ) New: rizr APPLICANT ❑ CONTACT PERSON NOTICE Business name: i All contractors and subcontractors are required to be A / licensed with the Oregon Construction Contractors Board Contact name: Jo LA ' friyi . under ORS 701 and may be required to be licensed in the Address: h3OS S. iJ • i o S ti.Jod 51. jurisdiction in which work is being performed. If the City /State /ZIP: L OS t „)e, l 4 p applicant is exempt from licensing, the following reasons ,} - l 9 70 3S apply: Phone: (,,ro3) 653 . .9000 Fax:: ( ) E -mail: jovokei so43 Si m.9(exefft i,1 , 11 . ?VIA . CONTRA TOR BUILDING PERMIT FEES* Lei , (Please refer to fee schedule) Business name: 5Ultw (? I�Z.X �� r A .(/tej Permit fee: Address: State surcharge (12% of permit fee): City /State /ZIP: o FLS plan review (40% of permit fee): Phone: ( ) Fax: ( ) (Due upon application.) CCB lic.: /tf T 3. 1 Total permit fees: Authorized signs re: � . (/‘_/,_. Amount received: 7Z Ag This permit application expires if a permit is not obtained Print name: Date: q . oq within 180 days after it has been accepted as complete. �J IA. Q S�� 1 0 , z , * Fee methodology set by Tri- County Building Industry Service Board. I: \Building \Permits \FPS - PermitApp.doc 10/01/09 440-4613T(1 I /02/COM/WEB) City of Tigard: Fire Protection Permit Checklist Page 2 - Supplemental Information Describe work to be done: 1.) ❑ New 2.) Modification to sprinkler heads only. ❑ Addition 1 -10 heads: No plan review required. 1 ( Alteration ❑ 11+ heads: Plan review required. ❑ Repair Number of sprinkler heads: .5 Additional description of work Type of System (Complete A, B, C or D as applicable): A.) Commercial Sprinkler [e" Wet ❑ Dry Additional Standpipes Information: Hazard Group Liclk Density m 6 Design Area ( Q 5 K. Factor 5; 6 Sprinkler Project Valuation: $ q 50. o B.) Type I - Hood Fire Suppression System Hood Project Valuation: $ C.) Fire Alarm Submittal shall Battery Calculations ❑ Yes include: Individual Component El Yes Cut Sheets Fire Alarm Project Valuation: $ D.) Residential Sprinkler (Stand Alone System) Square Footage: Permit Fee: 0 to 2,000 $198.75 2,001 to 3,600 $246.45 3,601 to 7,200 $310.05 7,201 and greater $404.39 Sprinkler Project Square Footage: sq. ft. Fire Protection Permit Fees Project valuation subtotal (see A, B & C above): $ Permit fee based on project valuation (see fee schedule): $ Permit fee based on square footage (see D above): $ State Surcharge (12% of permit fee): $ FLS Plan Review (40% of permit fee): $ TOTAL: $ Plan review requires a completed application and 2 sets of plans at submittal. Plan review fees are required at submittal. http: / /www.tigard- or.gov /city hall /departments /cd/docs /FPS- PermitApp.doc 10 /O1 /23 tqc.., I Fire & Building Products Technical Services: Tel: (800) 381 -9312 / Fax: (800) 791 -5500 Series TY -F ® 22, 4.2, 506, and 8.0 K®factor Us right, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage tained when exposed to corrosive at- eneral mospheres. Although corrosion resis- tant coated sprinklers have passed the Description standard corrosion tests of the appli- d ' cable approval agencies, the testing is E The Tyco® Series TY -FRB, 2.8, 4.2, not representative of all possible car- 5.6, and 8.0 K- factor, Upright and Pen- rosive atmospheres. Consequently, it I *` ;w dent Sprinklers described in this data is recommended that the end user be sheet are quick response - standard r �� '- q P consulted with respect to the suitability coverage, decorative 3 mm glass bulb of these coatings for any given corro- type spray sprinklers designed for use sive environment. The effects of ambi- in light or ordinary hazard, commercial ent temperature concentration of Y , 3 " occupancies such as banks, hotels, p chemicals, and gas /chemical velocity, shopping malls, etc. should be considered, as a minimum, The recessed version of the Series along with the corrosive nature of the TY -FRB Pendent Sprinkler, where ap- chemical to which the sprinklers will be plicable, is intended for use in areas exposed. with a finished ceiling. It uses either a An intermediate level versions of the two -piece Style 10 (1/2 inch NPT) or Series TY -FRB Pendent Sprinklers Style 40 (3/4 inch NPT) Recessed Es- are detailed in Technical Data Sheet i x ' '• cutcheon with 1/2 inch (12,7 mm) of TFP356, and Sprinkler Guards are de- recessed adjustment or up to 3/4 inch tailed in Technical Data Sheet TFP780 (19,1 mm) of total adjustment from the flush pendent position, or a two -piece WARNINGS Style 20 (1/2 inch NPT) or Style 30 (3/4 The Series TY -FRB Sprinklers de- inch NPT) Recessed Escutcheon with scribed herein must be installed and -` 1/4 inch (6,4 mm) of recessed adjust- maintained in compliance with this ment or up to 1/2 inch (12,7 mm) of document, as well as with the applica- total adjustment from the flush pen- ble standards of the National Fire Pro - dent position. The adjustment pro- tection Association, in addition to the vided by the Recessed Escutcheon re- standards of any other authorities hay- Model/Sprinkler duces the accuracy to which the fixed ing jurisdiction. Failure to do so may pipe drops to the sprinklers must be impair the performance of these de- Identification cut. vices. Corrosion resistant coatings, where The owner is responsible for maintain Numbers applicable, are utilized to extend the ing their fire protection system and de- life of copper alloy sprinklers beyond vices in proper operating condition. TY1131 - Upright 2.8K, 1/2 "NPT that which would otherwise be ob- The installing contractor or sprinkler TY1231 - Pendent 2.8K, 1/2 "NPT manufacturer should be contacted TY2131 - Upright 4.2K, 1/2 "NPT with any questions. TY2231 - Pendent 4.2K, 1/2 "NPT IMPORTANT TY3131 - Upright 5.6K, 1/2 "NPT Always refer to Technical Data TY3231 - Pendent 5.6K, 1/2 "NPT Sheet TFP700 for the "INSTALLER TY4131 - Upright 8.0K, 3/4 "NPT WARNING" that provides cautions TY4231 - Pendent 8.0K, 314 "NPT with respect to handling and instal- TY4831- Upright 8.0K, 1/2 "NPT lation of sprinkler systems and com- TY4931- Pendent 8.0K, 1/2 "NPT ponents. Improper handling and in- stallation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 10 AUGUST, 2007 TFP171 Page 2 of 10 TFP171 ESCUTCHEON 7/16" (11,1 mm) STYLE 10 or 20 PLATE SEATING NOMINAL RECESSED SURFACE NPT MAKE -IN ESCUTCHEON DEFECTOR fIlMrr = m _ a - 1 - mil — — i !� ° 5 ��1'' � 2 -1/4" } � (11, 7/16" 1 1 m mm) 1 4 (57,2 mm) ��� � 1 i I iI NMAKE -IN 4 OMINAL I I 1 , 2 1-9/16" �� I� 71 � ` � 2- 3/16 " 7 3 (39,7 mm) WRENCH ! (55,6 mm) � \ r / i FLATS --- P., f 1 .4v-r.or-la III limif SSP DEFLECTOR — 2 -7/8" (73,0 mm) DIA. 1 1/2" NPT f 7 PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression 7 - Bushing orifice seat on frame. Screw FIGURE 1 QUICK RESPONSE SERIES TY -FRB UPRIGHT (TY1131) AND PENDENT (TY1231) SPRINKLERS 2.8 K- FACTOR, 1/2 INCH NPT ESCUTCHEON 7/16" (11,1 mm) STYLE 10 or 20 PLATE SEATING NOMINAL RECESSED SURFACE NP MAKE-IN ESCUTCHEON DEFLECTOR 6 .- �= W s = � Oly i rr 7/16" '; 2- 3/16" 1 } �1''�� (11,1 mm) ��I ∎ � A�� 1111 I NOMINAL ; ■ (55,6 mm) 4 f 1 MAK -IN 2- 3/16" 1-1/2" 1I i i ' `�� 1 V#-,* 1 2 (38,1 mm) I WRENCH 1 (55,6 mm)p . F LATS 3 SSP DEFLECTOR 2 -7/8" (73,0 mm) DIA. 1/2" NPT PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression orifice seat on frame. Screw FIGURE 2 QUICK RESPONSE SERIES TY -FRB UPRIGHT (TY2131) AND PENDENT (TY2231) SPRINKLERS 4.2 K- FACTOR, 1/2 INCH NPT TFP171 Page 3 of 10 ESCUTCHEON 7/16" (11,1 mm) STYLE 10 or 20 PLATE SEATING NOMINAL RECESSED SURFACE NFT MAKE -IN ESCUTCHEON DEFLECTOR f = _ 5 1== ii IN ( 7 116" ) 2- 3/16" � � � 11,1 mm (55,6 mm) 1 A = � ���- NOMINAL ; 4 7�1 MAKE -IN 1 -1 /2" I II' (38,1 mm) ` �, 2- 3/16" ,�� it WRENCH I (55,6 mm) 1 1 _ � - �� � � _. FLATS 3 SSP DEFLECTOR * - 2 -7/8" (73,0 mm) DIA. 1/2" NPT 1 PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression orifice seat on frame. Screw FIGURE 3 QUICK RESPONSE SERIES TY -FRB UPRIGHT (TY3131) AND PENDENT (TY3231) SPRINKLERS 5.6 K- FACTOR, 1/2 INCH NPT ESCUTCHEON 1/2" (12,7 mm) STYLE 30 or 40 PLATE SEATING NOMINAL RECESSED SURFACE NP MAKE-IN ESCUTCHEON T DEFLECTOR 6 1/2" ' 0 ' S 2- 5/16 ' \ ■--, � �� (12,7 mm) (58,7 mm) �� - 4 NOMINAL ; 1 - MAKE -IN 1 9/16" IV �If ` ) i 1i.7 b 2 (39,7 mm) WRENCH (57,2 mm 7 1 ii 7 y � 6 W 3 SSP DEFLECTOR* 2 -7/8" (73,0 mm) DIA. 3/4" NPT f PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression orifice seat on frame. - Screw FIGURE 4 QUICK RESPONSE SERIES TY -FRB UPRIGHT (TY4131) AND PENDENT (TY4231) SPRINKLERS 8.0 K- FACTOR, 3/4 INCH NPT Page 4 of 10 TFP171 7/16" (11,1 mm) 1!2" NOMINAL SSU * NPT MAKE -IN DEFLECTOR t .._-- 6 r = ' t 5 �� 2 -1/4" 2 -3/1 I (57,2 mm) I =i' I (55,6 6 mm) I ' 4 1-9/16" i WRENCH ��� Ff 1 2 �■■• (39,7 mm) FLATS l - .! - -- - - 1 SSP * DEFLECTOR CROSS PENDENT UPRIGHT SECTION 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression orifice seat on frame. Screw FIGURE 5 QUICK RESPONSE SERIES TY -FRB UPRIGHT (TY4831) AND PENDENT (TY4931) SPRINKLERS 8.0 K- FACTOR, 1/2 INCH NPT Technical Operation Data The glass Bulb contains a fluid which expands when exposed to heat. When Approvals the rated temperature is reached, the UL and C -UL Listed. fluid expands sufficiently to shatter the FM, LPCB, and NYC Approved. glass Bulb, allowing the sprinkler to (Refer to Table A and B for complete activate and water to flow. approval information including corro- sion resistant status.) Design Maximum Working Pressure Refer to Table C. Criteria Discharge Coefficient K = 2.8 GPM /psi (40,3 LPM /bar1/2) The Series TY -FRB Pendent and Up- K = 4.2 GPM /psi (60,5 LPM /bar1 /2) right Sprinklers are intended for fire K = 5.6 GPM /psi (80,6 LPM /bar1/2) protection systems designed in ac- K = 8.0 GPM /psi (115,2 LPM /barli2) cordance with the standard installation rules recognized by the applicable Temperature Ratings Listing or Approval agency (e.g., UL Refer to Table A and B Listing is based on the requirements of Finishes NFPA 13, and FM Approval is based Sprinkler: Refer to Table A and B. on the requirements of FM's Loss Pre - Recessed Escutcheon: White Coated, vention Data Sheets ). Only the Style Chrome Plated, or Brass Plated. 10, 20, 30, or 40 Recessed Escutch- eon, as applicable, is to be used for recessed pendent installations. Physical Characteristics 8 Frame Bronze E Button Brass /Copper m Sealing Assembly 1- Beryllium Nickel w/Teflont a' Bulb Glass iv Compression Screw Bronze .6 Deflector Copper /Bronze cc Bushing (K =2.8) Bronze 0 0 0 4— TFP171 Page 5 of 10 SPRINKLER FINISH (See Note 7) K TYPE TEMP. BULB NATURAL CHROME WHITE*** LIQUID BRASS PLATED POLYESTER 135 °F /57 °C Orange PENDENT 155 °F /68 °C Red (TY1231) 1, 2, 3, 5 and 175 °F /79 °C Yellow UPRIGHT 200 °F /93 °C Green 2.8 (n1131) 286 °F /141 °C Blue 1/2" NPT 135 °F /57 °C Orange RECESSED 155 °F /68 °C Red PENDENT (TY1231)* 175F/79°C Yellow Figure 6 200 °F /93 °C Green 1, 2, 5 135 °F /57 °C Orange RECESSED 155F/68°C Red PENDENT (TY1231)** 175 °F /79 °C Yellow Figure 7 200 °F /93 °C Green 135 °F /57 °C Orange PENDENT 155 °F /68 °C Red (TY2231) and 175F/79°C Yellow UPRIGHT 200F/93°C Green 4.2 (TY2131) 286 °F /141 °C Blue 1 2 1/2" NPT 135 °F /57 °C Orange RECESSED 155 °F /68 °C Red PENDENT (TY2231)* 175 °F /79 °C Yellow Figure 8 200F/93°C Green 135 °F /57 °C Orange RECESSED 155F/68°C Red PENDENT (TY2231) ** 175 °F /79 °C Yellow Figure 9 200 °F /93 °C Green NOTES: 1. Listed by Underwriters Laboratories, Inc. (UL) as Quick Response Sprinklers. 2. Listed by Underwriters Laboratories, Inc. for use in Canada (C -UL) as Quick Re- sponse Sprinklers. 3. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprin- klers. 5. Approved by the City of New York under MEA 354 -01 -E. 7. Where Polyester Coated Sprinklers are noted to be UL and C -UL Listed, the sprin- klers are UL and C -UL Listed as Corrosion Resistant Sprinklers. * Installed with Style 10 (1/2" NPT) or Style 40 (3/4" NPT) 3/4" Total Adjustment Recessed Escutcheon, as applicable. ** Installed with Style 20 (1/2" NPT) or Style 30 (3/4" NPT) 1/2" Total Adjustment Recessed Escutcheon, as applicable. * ** Frame and Deflector only. Listings and approvals apply to color (Special Order). N /A: Not Available TABLE A LABORATORY LISTINGS AND APPROVALS 2.8 AND 4.2 K- FACTOR SPRINKLERS Page 6 of 10 TFP171 SPRINKLER FINISH (See Note 8) K TYPE TEMP. BULB NATURAL CHROME WHITE *** LEAD LIQUID BRASS PLATED POLYESTER COATED 135F/57°C Orange PENDENT 155 °F /68 °C Red (TY3231) 1,2,3,4,5,6,7 1,2,3,5 and 175 °F /79 °C Yellow UPRIGHT 200 °F /93 °C Green 5.6 (TY3131) 286F/141°C Blue 1/2" NPT 135 °F /57 °C Orange RECESSED 155 °F /68 °C Red PENDENT 1, 2, 4, 5 N/A (TY3231)* 175 °F /79 °C Yellow Figure 10 200 °F /93 °C Green 135 °F /57 °C Orange RECESSED 155 °F /68 °C Red PENDENT 1, 2, 3, 4, 5 N/A (TY3231) ** 175 °F /79 °C Yellow Figure 11 200 °F /93 °C Green 135 °F /57 °C Orange PENDENT 155 °F /68 °C Red (TY4231) 1, 2, 5 and 175 °F /79 °C Yellow 1, 2, 3, 4, 5, 6, 7 UPRIGHT 200 °F /93 °C Green 8.0 (TY4131) 286 °F /141 °C Blue 3/4" NPT 135 °F /57 °C Green RECESSED 155F/68°C Orange • PENDENT 1, 2, 4, 5 N/A (TY4231)* 175 °F /79 °C Red Figure 12 200 °F /93 °C Yellow 135 °F /57 °C Orange RECESSED 155 °F /68 °C Red PENDENT 1, 2, 3, 4, 5 N/A (TY4231) ** 175 °F /79 °C Yellow Figure 13 200 °F /93 °C Green 135 °F /57 °C Orange PENDENT 155 °F /68 °C Red 8.0 (TY4931) 1, 2, 5 1/2" and 175 °F /79 °C Yellow 1, 2, 4, 5, 6 NPT UPRIGHT 200 °F /93 °C Green (TY4831) 28&F/141°C Blue NOTES: 1. Listed by Underwriters Laboratories, Inc. (UL) as Quick Response Sprinklers. 2. Listed by Underwriters Laboratories, Inc. for use in Canada (C -UL) as Quick Response Sprinklers. 3. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers. 4. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 007k/04) as Quick Response Sprinklers; however, the LPCB does not rate the thermal sensitivity of recessed sprinklers. 5. Approved by the City of New York under MEA 354 -01 -E. 6. VdS Approved (For details contact Tyco Fire & Building Products, Enschede, Netherlands, Tel. 31 -53- 428- 4444/Fax 31 -53- 428 - 3377). 7. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/06) as Quick Response Sprinklers. 8. Where Polyester Coated and Lead Coated Sprinklers are noted to be UL and C -UL Listed, the sprinklers are UL and C -UL Listed as Corrosion Resistant Sprinklers. Where Lead Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as a Corrosion Resistant Sprinklers. * Installed with Style 10 (1/2" NPT) or Style 40 (3/4" NPT) 3/4" Total Adjustment Recessed Escutcheon, as applicable. ** Installed with Style 20 (1/2" NPT) or Style 30 (3/4" NPT) 1/2" Total Adjustment Recessed Escutcheon, as applicable. * ** Frame and Deflector only. Listings and approvals apply to color (Special Order). N /A: Not Available TABLE B LABORATORY LISTINGS AND APPROVALS 5.6 AND 8.0 K- FACTOR SPRINKLERS TFP171 Page 7 of 10 SPRINKLER FINISH K TYPE NATURAL CHROME WHITE LEAD BRASS PLATED POLYESTER COATED PENDENT (TY3231) and 2.8 UPRIGHT (TY3131) 175 PSI (12,1 BAR) N/A 1/2" RECESSED PENDENT NPT (TY323) PENDENT (TY4231) and 4.2 UPRIGHT (TY4131) 175 PSI (12,1 BAR) N/A 3/4" RECESSED PENDENT NPT (TY4231) PENDENT (TY3231) and 250 PSI (17,2 BAR) 175 PSI (12,1 BAR) 5.6 UPRIGHT (TY3131) OR 1/2" RECESSED PENDENT 175 PSI (12,1 BAR) NPT (TY3231) N/A (SEE NOTE 1) PENDENT (TY4231) and 175 PSI (12,1 BAR) 175 PSI (12,1 BAR) 8.0 UPRIGHT (TY4131) 3/4" RECESSED PENDENT NPT (TY4231) N/A 8.0 PENDENT (TY4931) 1/2" and 175 PSI (12,1 BAR) 175 PSI (12,1 BAR) NPT UPRIGHT (TY4831) NOTES: 1. The maximum working pressure of 250 psi (17,2 bar) only applies to the Listing by Underwriters Laboratories Inc. (UL); the Listing by Underwriters Laboratories, Inc. for use in Canada (C -UL); and , the Approval by the City of New York. TABLE C, MAXIMUM WORKING PRESSURE ®® tained with a torque of 10 to 20 ft.lbs. the sprinkler into the sprinkler fitting. Installation (13,4 to 26,8 Nm). A maximum of 30 Step 3. Tighten the sprinkler into the ft.lbs. (40,7 Nm) of torque is to be used sprinkler fitting using only the W -Type The Series TY -FRB Sprinklers must to install sprinklers with 3/4 NPT con - 6 Sprinkler Wrench (Ref. Figure 14). be installed in accordance with the fol- nections. Higher levels of torque may With reference to Figures 1, 2, 3, 4, lowing instructions: distort the sprinkler inlet and cause and 5, the W -Type 6 Sprinkler Wrench leakage or impairment of the sprinkler. is to be applied to the sprinkler wrench NOTES Do not attempt to make -up for insuffi- flats. Do not install any bulb type sprinkler if cient adjustment in the escutcheon The Series TY -FRB Recessed Pen - the bulb is cracked or there is a loss of plate by under- or over - tightening the dent Sprinklers must be installed in liquid from the bulb. With the sprinkler sprinkler. Readjust the position of the accordance with the following instruc- held horizontally, a small air bubble should be present. The diameter of the sprinkler fitting to suit. tions. air bubble is approximately 1/16 inch The Series TY -FRB Pendent and Up- Step A. After installing the Style 10. (1,6 mm) for the 135 °F /57 °C to 3/32 right Sprinklers must be installed in 20, 30, or 40 Mounting Plate, as appli- inch (2,4 mm) for the 286 °F /141 °C accordance with the following instruc- cable, over the sprinkler threads and temperature ratings. tions. with pipe thread sealant applied to the A leak tight 1/2 inch NPT sprinkler joint Step 1. Pendent sprinklers are to be pipe threads, hand tighten the sprin- should be obtained with a torque of 7 installed in the pendent position, and kler into the sprinkler fitting. to 14 ft.lbs. (9,5 to 19,0 Nm). A maxi- upright sprinklers are to be installed in Step B. Tighten the sprinkler into the mum of 21 ft. lbs. (28,5 Nm) of torque the upright position. sprinkler fitting using only the W -Type may be used to install sprinklers with S 2. Wi pipe thread sealant ap 7 Recessed Sprinkler Wrench (Ref. 1/2 NPT connections. A leak tight 3/4 Figure 15). With reference to Figure 1, inch NPT sprinkler joint should be ob- plied to the pipe threads, hand tighte 2, 3, and 4, the W -Type 7 Recessed Page 8 of 10 TFP171 2 -7/8" DIA. 2 -7/8" DIA. 5181114" (73,0 mm) 3/4" (19,1 mm) 1/211/8" (73,0 mm) 1/2" (12,7 mm) (15,916,4 mm) 2 -1/4" DIA. 1/4" (6,4 mm) (12,713,2 mm) 2 -1/4" DIA. 1/4" (6,4 mm) FACE OF (57,2 mm) MOUNTING FACE OF (57,2 mm) MOUNTING SPRINKLER PLATE SPRINKLER PLATE FITTING FITTING 1/8" 1/8" �� •�' (3,2 mm) •�. ( 3,2 mm) ----------- ltll,� r -ili iii" lim /il M =lii%r 1 _ - 1 ` 111 f MOUNTING MOUNTING �: SURFACE . SURFACE w, - .1�. �%r - l"\ \. ' CLOSURE SERIES 1- 5/16" (33,3 mm) CLOSURE SERIES 1- 5/16" (33,3 mm) TY -FRB 13/16" (20,6 mm) TY -FRB 1-1/16" (27,0 mm) FIGURE 6 FIGURE 7 SERIES TY -FRB RECESSED PENDENT SERIES TY -FRB RECESSED PENDENT WITH TWO -PIECE 3/4 INCH TOTAL ADJUSTMENT WITH TWO -PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON STYLE 20 RECESSED ESCUTCHEON 2.8 K- FACTOR, 1/2 INCH NPT 2.8 K- FACTOR, 1/2 INCH NPT 2 -7/8" DIA. 2 -7/8" DIA. 51811/4" (73,0 mm) 3/4" (19,1 mm) 1/211/8" (73,0 mm) 1/2" (12,7 mm) (15,916,4 mm) 2 -1/4" DIA. 1/4" (6,4 mm) (12,113,2 mm) 2 -1/4" DIA. 1/4" (6,4 mm) FACE OF (57,2 mm) MOUNTING FACE OF (57,2 mm) MOUNTING SPRINKLER PLATE SPRINKLER PLATE FITTING FITTING 1/8" 1/8" -1 •�' (3,2 mm) •� (3,2 mm) ,il�lli r �, iii" , frA _ - i, _-� 1 v U 1�� MOUNTING MOUNTING �: SURFACE II SURFACE -- - - CLOSURE SERIES 1 -1/4" (31,8 mm) CLOSURE SERIES 1 -1/4" (31,8 mm) TY -FRB 3/4" (19,1 mm) TY -FRB 1" (25,4 mm) FIGURE 8 FIGURE 9 SERIES TY -FRB RECESSED PENDENT SERIES TY -FRB RECESSED PENDENT WITH TWO -PIECE 3/4 INCH TOTAL ADJUSTMENT WITH TWO -PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON STYLE 20 RECESSED ESCUTCHEON 4.2 K- FACTOR, 1/2 INCH NPT 4.2 K- FACTOR, 1/2 INCH NPT Sprinkler Wrench is to be applied to work on the fire protection system that altered after leaving the factory. Modi- the sprinkler wrench flats. it controls, permission to shut down the fied sprinklers must be replaced. Step C. After the ceiling has been in- affected fire protection system must be Sprinklers that have been exposed to stalled or the finish coat has been ap- obta from the proper authorities corrosive products of combustion, but plied, slide on the Style 10, 20, 30, or and all personnel who maybe affected have not operated, should be replaced 40 Closure over the Series TY -FRB by th action must be notified if they cannot be completely cleaned Sprinkler and push the Closure over The owner must assure that the sprin- by wi the sprinkler with a cloth or the Mounting Plate until its flange klers are not used for hanging of any by brush i t w a soft bristle brush. comes in contact with the ceiling. objects; otherwise, non - operation in Care must be exercised to avoid dam- the event of a fire or inadvertent opera- age to the sprinklers - before, during, Care and tion may result. and after installation. Sprinklers dam - Absence of an escutcheon, which is aged by dropping, striking, wrench used to cover a clearance hole, may twist/slippage, or the like, must be re- Maintenance delay the time to sprinkler operation in placed. Also, replace any sprinkler The Series TY -FRB Sprinklers must a fire situation. that has a cracked bulb or that has lost P liquid from its bulb. (Ref. Installation tallation be maintained and serviced in accord- Sprinklers that are found to be leaking Section). ance with the following instructions: or exhibiting visible signs of corrosion must be replaced. Frequent visual inspections are rec- NOTES ommended to be initially performed for Before closing a fire protection system Automatic sprinklers must never be corrosion resistant coated sprinklers, main control valve for maintenance painted, plated, coated or otherwise after the installation has been com- TFP171 Page 9 of 10 2 -7/8" DIA. 2 -7/8" DIA. (73,0 mm) 3/4" (19,1 mm) 1/212,7 mm (73,0 mm) " 518±1/4" ( ) _ 1/2±1/8" (12,7 mm) (15,9±6,4 mm) 2.1/4" DIA. 1/4" (6,4 mm) (12,7±3,2 mm) 2-1/4" DIA. 1/4" (6,4 mm) FACE OF (57,2 mm) MOUNTING FACE OF (57,2 mm) MOUNTING SPRINKLER PLATE SPRINKLER PLATE FITTING FITTING 1/8" I 1/8" A �� ∎i� — f MOUNTING 1 101 MOUNTING , , 1 SURFACE SURFACE i , _I_.,- CLOSURE SERIES 1 -1/4" (31,8 mm) CLOSURE SERIES 1 -1/4" (31,8 mm) TY -FRB 3/4" (19,1 mm) TY -FRB 1" (25,4 mm) FIGURE 10 FIGURE 11 SERIES TY -FRB RECESSED PENDENT SERIES TY -FRB RECESSED PENDENT WITH TWO -PIECE 3/4 INCH TOTAL ADJUSTMENT WITH TWO -PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON STYLE 20 RECESSED ESCUTCHEON 5.6 K- FACTOR, 1/2 INCH NPT 5.6 K- FACTOR, 1/2 INCH NPT 2 -7/8" DIA. _ 2 -7/8" DIA. - 5/8 ±1/4" (73,0 mm) 3/4" (19,1 mm) 1/2±1/8" (73,0 mm) 1/2" (12,7 mm) (15,9±6,4 mm) 2 -1/4" DIA. 1/4" (6,4 mm) (12,7±3,2 mm) 2 -1/4" DIA. 1/4" (6,4 mm) (57,2 mm) MOUNTING FACE OF (57,2 mm) FACE OF MOUNTING SPRINKLER PLATE SPRINKLER PLATE FITTING FITTING 1/8" 1/8" illi `. .1II (3,2 mm) " (3,2 mm) Al A 1 2/11 re I I . %, ' Al , 1 , i ' MOUNTING VIV 1 MOUNTING SURFACE SURFACE . • r CLOSURE SERIES 1- 5/16" (33,3 mm) CLOSURE SERIES 1- 5/16" (33,3 mm) TY -FRB 13/16" (20,6 mm) TY -FRB 1- 1/16" (27,0 mm) FIGURE 12 FIGURE 13 SERIES TY -FRB RECESSED PENDENT SERIES TY -FRB RECESSED PENDENT WITH TWO -PIECE 3/4 INCH TOTAL ADJUSTMENT WITH TWO -PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON STYLE 30 RECESSED ESCUTCHEON 8.0 K- FACTOR, 3/4 INCH NPT 8.0 K- FACTOR, 3/4 INCH NPT pleted, to verify the integrity of the cor- G WRENCH rosion resistant coating. Thereafter, RECESS annual inspections per NFPA 25 should suffice; however, instead of in- WRENCH RECESS sielF".. specting from the floor level, a random (END "A" USED FOR fj sampling of close -up visual inspec- 1/2" NPT MODELS) tions should be made, so as to better —...d determine the exact sprinkler condi- S ' tion and the long term integrity of the .........• corrosion resistant coating, may as it ma WRENCH RECESS be affected by the corrosive conditions (END "B" USED FOR PUSH WRENCH IN TO ENSURE 3/4" NPT MODELS) present. ENGAGEMENT The owner is responsible for the In FIGURE 14 WITH SPRINKLER WRENCHING AREA spection, testing, and maintenance of W -TYPE 6 SPRINKLER their fire protection system and de- WRENCH FIGURE 15 vices in compliance with this docu- W -TYPE 7 RECESSED ment, as well as with the applicable SPRINKLER WRENCH standards of the National Fire Protec facturer should be contacted relative tion Association (e.g., NFPA 25), in to any questions. addition to the standards of any other It is recommended that automatic Inspection Service n ts and d /or /or nati an with local l requirements authorities having jurisdiction. The in- sprinkler systems be inspected, national codes. stalling contractor or sprinkler manu- tested, and maintained by a qualified • Page 10 of 10 TFP171 P/N 57 - XXX - X - XXX I I TEMPERATURE MODEL /SIN RATING SPRINKLER 330 2.8K UPRIGHT (1/2 "NPT) TY1131 135 135 °F /57 °C 331 2.8K PENDENT (1/2 "NPT) TY1231 1 NATURAL BRASS 155 155 °F /68 °C 340 4.2K UPRIGHT (1/2 "NPT) TY2131 4 WHITE POLYESTER 175 175 °F /79 °C 341 4.2K PENDENT (1/2 "NPT) TY2231 3 WHITE (RAL9010)* 200 200 °F /93 °C 370 5.6K UPRIGHT (1/2 "NPT) TY3131 9 CHROME PLATED 286 286 °F /141 °C 371 5.6K PENDENT (1/2 "NPT) TY3231 7 LEAD COATED 390 8.0K UPRIGHT (3/4 "NPT) TY4131 391 8.0K PENDENT (3/4 "NPT) TY4231 * Eastern Hemisphere sales only. 360 8.0K UPRIGHT (1/2 "NPT) TY4831* 361 8.0K PENDENT (1/2 "NPT) TY4931* TABLE D PART NUMBER SELECTION SERIES TY -FRB PENDENT AND UPRIGHT SPRINKLERS In no event shall TFBP be liable, in Ordering Limited contract, tort, strict liability or under any other legal theory, for incidental, ldam- Procedure Warranty indirect, special or consequential dam- ages, including but not limited to labor Products manufactured by Tyco Fire & charges, regardless of whether TFBP When placing an order, indicate the Building Products (TFBP) are war- was informed about the possibility of full product name. Refer to the Price ranted solely to the original Buyer for such damages, and in no event shall List for complete listing of Part Num- ten (10) years against defects in mate- TFBP's liability exceed an amount bers. rial and workmanship when paid for equal to the sales price. Contact your local distributor for avail - and properly installed and maintained under normal use and service. This The foregoing warranty is made in lieu ability. warranty will expire ten (10) years of any and all other warranties. ex from date of shipment by TFBP. No press or implied. including warranties Sprinkler Assemblies with NPT warranty is given for products or com- of merchantability and fitness for a par- Thread Connections: ponents manufactured by companies ticular purpose. Specify: (Specify Model /SIN), Quick not affiliated by ownership with TFBP This limited warranty sets forth the ex- Response, ( specify K-factor), ( specif or for products and components which Y temperature (specify en rating), Series pri FRB P p clusive remedy for claims based on (specify Pendent or Upright) Sprinkler have been subject to misuse, improper failure of or defect in products, materi- with (specify type of finish or coating), installation, corrosion, or which have als or components, whether the claim P/N (specify from Table D). not been installed, maintained, modi- is made in contract, tort, strict liability fied or repaired in accordance with ap- or any other legal theory. Recessed Escutcheon: plicable Standards of the National Fire 20 Protection Association, and /or the This warranty will apply to the full ex- Specify: Style Y ( 10, 40) Re standards of any other Authorities tent permitted by law. The invalidity, in cessed Escutcheon with 30, or 40 th (specify) fin - Having Jurisdiction. Materials found whole or part, of any portion of this ish, P/N (specify *). by TFBP to be defective shall be either warranty will not affect the remainder. • Refer to Technical Data Sheet TFP770. repaired or replaced, at TFBP's sole option. TFBP neither assumes, nor Sprinkler Wrench: authorizes any person to assume for it, Specify: W -Type 6 Sprinkler Wrench, any other obligation in connection with P/N 56- 000 -6 -387. the sale of products or parts of prod- ucts. TFBP shall not be responsible for Specify: W -Type 7 Sprinkler Wrench, sprinkler system design errors or inac- P/N 56- 850 -4 -001. curate or incomplete information sup- plied by Buyer or Buyer's repre- sentatives. TYCO FIRE & BUILDING PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446