Permit
CITY OF TIGARD FIRE PROTECTION SYSTEM PERMIT COMMUNITY DEVELOPMENT Permit #: FPS2010 -00002 4.[ G ARt); 13125 SW Hall Blvd., Tigard OR 97223 503.639.4171 Date Issued: 01/12/2010 Parcel: 1S133AD02200 Jurisdiction: Tigard Site address: 10730 SW 130TH AVE Subdivision: Lot: 0 Project: Westgate Baptist Project Description: Relocate (4) heads and add (6) heads for stage area. Owner: FEES WESTGATE BAPTIST CHURCH Description Date Amount 12930 SW SCHOLLS FERRY RD TIGARD, OR 97223 Permit Fee - COM 01/12/2010 $102.20 12% State Surcharge - Building 01/12/2010 $12.26 PHONE: Contractor: WYATT FIRE PROTECTION INC. 9095 SW BURNHAM TIGARD, OR 97223 PHONE: 503 - 684 -2928 FAX: 503 - 684 -9657 Type of Use: Class of Work: Type of Const: Occupancy Grp: Height: ft Stories: Commercial Sprinkler System: Sprinkler Required: Sprinkler Type: Standpipe Required: Hazard: Density: 0 Design Area: 0 K Factor: 0 Commercial Fire Alarm System: Fire Alarm Required: Alarm Type: Pull Station Required: Smoke Detectors Req: Battery Calcs Provided: Cut Sheets Required: Total $114.46 Valuations: Required Items and Reports (Conditions) Sprinkler Valuation: 0 Residential Square Footage: 0 Fire Alarm Valuation: 0 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952 - 001 -0010 through OAR 952 - 001 -0100. You may obtain a copy of the ru - or direct que • s to • • C • Itin. 03.246.6699 or 1.800.332.2344. Issued y: , /i (j - PermitteeSignature: Call 503.639.4175 by 7:00 a.m. for an inspection that busine . day. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. • t , . , t; Fine & Building I 4. Products JAN 1 2 2010 CITY OF TIGARD Technical Services: Tel: (800) 381 -9312 / Fax: (800) 791 -5500 BUILDING DIVISION Series = F11 — 5e -fact • r "Royal Flush 11" e Concealed Sprinklers Quick Or Stan f•. and Response, Standard Coverage General Cap. The Protective Cap is temporarily removed for installation, and then it can be replaced to help protect the Description sprinkler while the ceiling is being in- stalled or finished. The tip of the Pro - The Series RFII Quick Response tective Cap can also be used to mark P-"3 (3 mm bulb) & Standard Response (5 the center of the ceiling hole into plas- mm bulb), 5.6 K- Factor, "Royal Flush ter board, ceiling tiles, etc. by gently II" Concealed Pendent Sprinklers are pushing the ceiling product against the decorative sprinklers featuring a flat Protective Cap. When the ceiling in- cover plate designed to conceal the stallation is complete the Protective sprinkler. It is the best choice for archi- Cap is removed and the Cover Plate tecturally sensitive areas such as hotel Assembly installed. lobbies, office buildings, churches, As an option, the Series RFII Standard and restaurants. Response (5 mm bulb) "Royal Flush II" Each unit includes a Cover Plate As- Concealed Pendent Sprinklers may be sembly that conceals the sprinkler op- fitted with a silicone Air and Dust Seal UL, C -UL, and NYC. Maximum 175 erating components above the ceiling. (Ref. Fig. 5). The Air and Dust Seal is psi (12,1 bar) by FM. The separable two -piece design of the intended for sensitive areas where it is Cover Plate and Support Cup Assem- desirable to stop air and dust travel Technical blies allows installation of the sprin- through the cover plate from the area klers and pressure testing of the fire above the ceiling. iu protection system prior to installation ata of a suspended ceiling or application WARNINGS of the finish coating to a fixed ceiling. The Series RFII Concealed Pendent Approvals for Series RFII They also permit removal of sus Sprinklers described herein must be UL and C -UL Listed. FM Approved. pended ceiling panels for access to installed and maintained in compli- NYC under MEA 353 -01 -E. LPCB (Ref. building service equipment without ance with this document, as well as No. 094a/09 for TY3551 & 094a/10 for having to first shut down the fire pro w ith the applicable standards of the TY3531) Approved. hav system and remove sprinklers. Nat F Protect Assoc The approvals apply only to the serv- Also, the separable two-piece design i addition to the standards of any ice conditions indicated in the Design Al AI the the Sprinkler provides for design other authorities having jurisdiction. Criteria section and maximum pres- of inch the th mm) okver provides des for adjustment, 2 Failure to do so may impair the per- sure ratings indicated in the formance of these devices. Model /Sprinkler Identification Num- to reduce the accuracy to which the The owner is responsible for maintain- bers section. length of fixed pipe drops to the sprin- klers must be cut. m g their fire protection system and de- Approvals for Air & Dust Seal The Series RFII Sprinklers vices in proper operating condition. (Part #10908100) T ers are shipped with a Disposable Protective are The installing contractor or sprinkler UL and C -UL Listed for use with the manufacturer should be contacted RFII (TY3551 & TY3504) Standard Re- with any questions. sponse Concealed Sprinkler. IMPORTANT Temperature Ratings Always refer to Technical Data Model/ Sprinkler 155F/68C Sprinkler - 135F/57C Plate Sheet TFP700 for the "INSTALLER g 200F/93C Sprinkler - 165F/74C Plate WARNING" that provides cautions ®dentificati n Discharge Coefficient with respect to handling and instal- K = 5.6 GPM /psi (80,6 LPM /bar lation of sprinkler systems and com- r lumbers Adjustment ponents. Improper handling and in- 1/2 inch (12,7 mm) stallation can permanently damage TY3551 (5mm bulb) & TY3531 (3 mm Finishes a sprinkler system or its compo- bulb): maximum 175 psi (12,1 bar) by Cover Plate: Chrome Plated, Brass nents and cause the sprinkler to fail UL, C -UL, FM, LPCB and NYC. Plated, or White Painted (Custom paint to operate in a fire situation or cause TY3504 (5mm bulb) & TY3505 (3 mm matches and colors other than white it to operate prematurely. bulb): maximum 250 psi (17,3 bar) by are available on request.) Page 1 of 4 JULY, 2004 TFP181 Page 2 of 4 YFP181 Physical Characteristics 1/2" NPT SEALING Frame Bronze ASSEMBLY Support Cup . Chrome Plated Steel Guide Pins Stainless Steel j � Deflector Bronze FRAME Compression Screw Brass 111 �`�� CAP Bulb Glass Cap Bronze or Copper SUPPORT Sealing Assembly CUP WITH t BULB Beryllium Nickel w/Teflon' ROLL FORMED Cover Plate Brass THREADS Retainer Brass ll $ COMPRESSION Ejection Spring . . . . Stainless Steel �, ( SCREW GUIDE Patents PINS (2) lir r - ' ! U.S.A. 4,014,388 Al ��iiEE I DEFLECTOR ■ (DROPPED O peration DEFLECTOR i i POSITION) ■ When exposed to heat from a fire, the SPRINKLER/SUPPORTCUP Cover Plate, which is normally sol- ASSEMBLY dered to the Retainer at three points, falls away t0 expose the Sprinkler As- THREAD INTO i I RETAINER sembl . At this oint the Deflector su _ SUPPORT CUP O I I ` WITH THREAD Y P P UNTIL MOUNTING O DIMPLES ported by the Guide Pins drops down SURFACE IS f0 its operational position. FLUSH WITH EJECTION The glass Bulb contains a fluid that CEILING SPRING expands when exposed to heat. When \ the rated temperature is reached, the fluid expands sufficiently to shatter the ��; glass Bulb, activating the sprinkler and allowing water to flow. SOLDER COVER TABS (3) COVER PLATE/RETAINER PLATE ASSEMBLY Design FIGURE 1 Criteria SERIES RFII CONCEALED SPRINKLER ASSEMBLY The RFII (TY3551 & TY3504), 5 mm Bulb Type, Concealed Pendent Sprin- Step 1. The sprinkler must only be klers are UL and C -UL Listed as stand- Installation installed in the pendent position and and response - standard spray sprin- with the centerline of the sprinkler per - klers for use in accordance with the The Series RFII must be installed in pendicular to the mounting surface. current NFPA standard. They are FM accordance with the following instruc- Step 2. Remove the Protective Cap. Approved as standard response - tions: Step 3. W ith pipe thread sealant a standard spray sprinklers for use in P P P P accordance with the current FM Loss NOTES plied to the pipe threads, hand tighten Prevention Data Sheets. Do not install any bulb type sprinkler if the sprinkler into the sprinkler fitting. the bulb is cracked or there is a loss of Step 4. Wrench tighten the sprinkler using only g P The RFII (TY3531 & TY3505) 3 mm liquid from the bulb. With the sprinkler P Bulb Type, Concealed Pendent Sprin- held horizontally, a small air bubble 9 y the RFII Sprinkler Wrench klers are UL and C -UL Listed as quick should be present. The diameter of the (Ref. Figure 3). The RFII Sprinkler response - standard spray sprinklers air bubble is approximately 1/16 inch Wrench is to be applied to the Sprin for use in accordance with the current kler as shown in Figure 3. (1,6 mm) for the 155 °F /68 °C and 3/32 NFPA standard. They are FM Ap- inch (2,4 mm) for the 200 °F /93 °C tem- Step 5. Replace the Protective Cap proved as standard response - stand- perature ratings. (Ref. Figure 4) by pushing it upwards and spray sprinklers for use in accord- A leak tight 1/2 inch NPT sprinkler joint until it bottoms out against the Support ance with the current FM Loss Cup. The Protective Cap helps prevent should be obtained with a torque of 7 Prevention Data Sheets. damage to the Deflector and Arms dur- to 14 ft./bs. (9,5 to 19,0 Nm). A maxi- The Series RFII Concealed Pendent mum of 21 ft.lbs. (28,5 Nm) of torque ing ceiling installation and /or during Sprinklers are only listed and ap- is to be used to install sprinklers. application of the finish coating of the proved with the Series RFII Concealed Higher levels of torque may distort the ceiling. It may also be used to locate Cover Plates having a metallic or white sprinkler inlet with consequent leak- the center of the clearance hole by painted finish. age or impairment of the sprinkler. gently pushing the ceiling material up Series RFII must not be used in against the center point of the Protec- The li Serie s where the air used in Do not attempt to compensate for in- tive Cap. applications pressure sufficient adjustment in the Sprinkler above the ceiling is greater than that Assembly by under- or over - tightening NOTE below. Down drafts through the Sup- the Sprinkler /Support Cup Assembly. As long as the Protective Cap remains port Cup could delay sprinkler opera- Readjust the position of the sprinkler in place, the system is considered to tion in a fire situation. fitting to suit. be "Out of Service ". * Registered Trademark of DuPont TFP181 Page 3 of 4 FACE OF CLEARANCE HOLE CLEARANCE . SPRINKLER t_ DIAMETER .- HOLE FITTING DIMENSION C SPRINKLER SUPP ORT CUP ASSEMBLY 11 1/2(12,7 mm) THREADED D ADJUSTMENT FACE OF CEILING -, o RETAINING RING I r FIGURE 4 MOUNTING ■ (- DISPOSABLE PROTECTIVE CAP SURFACE � � � � � � Step 6. After the ceiling has been com- ' — __ pleted with the 2 -1/2 inch (63,5 mm) \ t� diameter clearance hole and in prepa- 1 ration for installing the Cover Plate As sembly, remove and discard the Pro- 1 1 \ E-7-7,:"._- T ---: - :_` 1 r / / tective Cap, and verify that the 3/16" to 11/16" MANUFACTURER DEFLECTOR COVER PLATE Deflector moves up and down freely. If (4,8 to 17,5 mm) PRESET GAP IN DROPPED RETAINER the Sprinkler has been damaged and REFERENCE 3/32" (2,4 mm) POSITION ASSEMBLY the Deflector does not move up and down freely, replace the entire Sprin- COVER PLATE COVER PLATE kler assembly. Do not attempt to mod - PROFILE DEPTH DIAMETER ify or repair a damaged sprinkler. DIMENSION B DIMENSION Step 7. When installing an Air and Dust Seal, refer to Figure 5, otherwise proceed to Step 8. To attach the Air and A: 3 -1/4" (82,6 mm) C: 2 -3/8" to 2 -5/8" (60,3 to 66,7 mm) Dust Seal, verify the angle of the out - B: 3/16" (4,8 mm) D: 1 -3/4" to 2 -1/4" (44,5 to 57,2 mm) side edge of the seal is oriented ac- cording to Figure 5. Start the edge of FIGURE 2 the Retainer in the grooved slot of the SERIES RFII CONCEALED SPRINKLER Air and Dust Seal and continue around INSTALLATION DIMENSIONS Dust retainer until the entire Air and Dust Seal is engaged. NOTE The Air and Dust Seal is only to be installed on the periphery of the Re -- d FRAME J d, tainer. ARM r ir 1 Step 8. Screw on the Cover Plate /Re- . i ' tainer Assembly until the Retainer - Ti � Figure 2 (or Air and Dust Seal - Figure SUPPORT 5) contacts with the ceiling. Do not continue to screw on the Cover Itil - cuP Plate /Retainer Assembly such that it MI � � 1•1 . 4 lifts a ceiling panel out of its normal lit ,.. position. If the Cover Plate /Retainer Assembly cannot be engaged with the O Support Cup or the Cover Plate /Re- 7/8" (23 mm) tainer Assembly cannot be engaged SQUARE sufficiently to contact the ceiling, the Sprinkler Fitting must be repositioned. ALIGN Q Ar ARROWS WITH C are a rr J nI: FRAME ARMS ' `e ` ACCEPTS The Series RFII must be maintained O v2^ SOCKET and serviced in accordance with the DRIVE following instructions: NOTES FIGURE 3 • Absence of the Cover Plate Assembly RFII SPRINKLER WRENCH may delay sprinkler operation in a fire situation. Page4of4 TFP181 When properly installed, there is a SUPPORT SPRINKLER FACE OF ORIENT nominal 3/32 inch (2,4 mm) air gap CUP CEILING SEAL between the lip of the Cover Plate and BEVELAS the ceiling, as shown in Figure 2. This ` �_� C OVER ' SHOWN air gap is necessary for proper opera- ti P LA TE A , f ,; tion of the sprinkler. If the ceiling is to :0 ASSEMBLY ) RETAINER _ be repainted after the installation of l � the Sprinkler, care must be exercised c to ensure that the new paint does NOT .y, - seal off any of the air gap. 4 j i i I M OOM Factory painted Cover Plates MUST .1. 1.1 - NOT be repainted. They should be re �r = — _ -- -- LIP OF COVER SEAL placed, if necessary, by factory RETAINER PLATE painted units. FIGURE 5 Do not pull the Cover Plate relative to OPTIONAL AIR AND DUST SEAL FOR SERIES RFII (TY3551 & TY3504) the Enclosure. Separation may result. Before closing fire protection system Inspection Service in accordance with DAMAGES, AND IN NO EVENT main control valve for maintenance local requirements and /or national SHALL TYCO FIRE PRODUCTS' LI- work on the fire protection system that codes. ABILITY EXCEED AN AMOUNT it controls, permission to shutdown the EQUAL TO THE SALES PRICE. affected fire protection system must be THE FOREGOING WARRANTY IS obtained from the proper authorities ___ MADE IN LIEU OF ANY AND ALL and all personnel who maybe affected OTHER WARRANTIES EXPRESS OR by this action must be notified. rranty IMPLIED. INCLUDING WARRANTIES Sprinklers that are found to be leaking OF MERCHANTABILITY AND FIT - or exhibiting visible signs of corrosion Products manufactured by Tyco Fire NESS FOR A PARTICULAR PUR- must be replaced. Products are warranted solely to the POSE Automatic sprinklers must never be original Buyer for ten (10) years t mus ve against defects in material and work- Au painted, plated, sprinklers or otherwise be manship when paid for and properly Ordering altered after leaving the factory. Modi- installed and maintained under normal fied sprinklers must be replaced. use and service. This warranty will ex- Procedure Sprinklers that have been exposed to pire ten (10) years from date of ship - corrosive products of combustion, but ment by Tyco Fire Products. No war- When placing an order, indicate the full have not operated, should be replaced ranty is given for products or product name. Contact your local dis- if they cannot be completely cleaned p y by wiping the sprinkler with a cloth or nies components noaff affiliated manufactured by compa- i with tributor for availability. Hies not affiliated by ownership with by brushing it with a soft bristle brush. Tyco Fire Products or for products and Sprinkler Assembly: Care must be exercised to avoid dam- components which have been subject Specify: (SIN), (specify temperature age to the sprinklers - before, during, to misuse, improper installation, corro- rating) Series RFII Concealed Pen dent Sprinkler, P/N (specify). and after installation. Sprinklers dam- sion, or which have not been installed, aged by dropping, striking, wrench maintained, modified or repaired in ac - 155F/68C 200F/93C twist/slippage, or the like, must be re- cordance with applicable Standards of Ty3551 51- 790 -1 -155 51- 790 -1 -200 placed. Also, replace any sprinkler that the National Fire Protection Associa- TY3504 51- 796 -1 -155 51- 796 -1 -200 has a cracked bulb or that has lost tion, and /or the standards of any other TY3531 51- 792 -1 -155 51 -792 -1 -200 liquid from its bulb. (Ref. Installation Authorities Having Jurisdiction. Mate - TY3505 51- 797 -1 -155 51- 797 -1 -200 Section). rials found by Tyco Fire Products to be If a sprinkler must be removed, do not defective shall be either repaired or Separately Ordered Cover Plate: reinstall it or a replacement without replaced, at Tyco Fire Products' sole Specify: (specify temperature rating) reinstalling the Cover Plate Assembly. option. Tyco Fire Products neither as- Series RFII Concealed Cover Plate If a Cover Plate Assembly becomes sumes, nor authorizes any person to with (specify finish), P/N (specify). dislodged during service, replace it im- assume for it, any other obligation in mediately. connection with the sale of products or Brass 56 -792 1-1 56 2 parts of products. Tyco Fire Products Bright Brass 56- 792 -2 -135 56- 792 -2 -165 The owner is responsible for the in- shall not be responsible for sprinkler Chrome 56- 792 -9 -135 56- 792 -9 -165 spection, testing, and maintenance of system design errors or inaccurate or Brushed Chrome - - -- their fire protection system and de- incomplete information supplied by White 56 792 -3 -135 792 -8 -135 56 792 792 -3 8 -165 165 P Y p pp Y White (RAL9010)' 56- 792 -3 -135 56- 792 -3 -165 vices in compliance with this docu- Buyer or Buyer's representatives. Bright White 56- 792 -4 -135 56- 792 -4 -165 ment, as well as with the applicable IN NO EVENT SHALL TYCO FIRE Off White 56- 792 -5 -135 56- 792 -5 -165 standards of the National Fire Protec- PRODUCTS BE LIABLE, IN CON- Cla 56-792-6-135 56- 792 -X -165 Custom 56- 792 -X -135 56- 792 -X -165 tion Association (e.g., NFPA 25), in TRACT, TORT, STRICT LIABILITY OR (a) For use with 155F/68C sprinklers. addition to the standards of any other UNDER ANY OTHER LEGAL THE- (b) For use with 200F/93C sprinklers. authorities having jurisdiction. The in- ORY, FOR INCIDENTAL, INDIRECT, * Eastern Hemisphere sales only. stalling contractor or sprinkler manu- SPECIAL OR CONSEQUENTIAL Sprinkler Wrench: facturer should be contacted relative to DAMAGES, INCLUDING BUT NOT Specify: R Wre Sprinkler Wrench, any questions. LIMITED TO LABOR CHARGES, RE- p y p It is recommended that automatic GARDLESS OF WHETHER TYCO P/N 56-000-1-075. sprinkler systems be inspected, FIRE PRODUCTS WAS INFORMED Air and Dust Seal: tested, and maintained by a qualified ABOUT THE POSSIBILITY OF SUCH Specify: Air and Dust Seal, P/N 56- 908 -1 -001. TYCO FIRE PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 • flkaikling Permit Application Fire Protection System ^ FOR OFFICE USE ONLY I . h City of Tigard Date/By: f i2- /0 Permit No.: p /ARM- - Qz0.2 j - 't 13125 SW Hall Blvd., Tigard, OR 97223 Plan Review Phone: 503.639.4171 Fax: 503.598.1960 Date/By: Other Permit: TIGARD Inspection Line: 503.639.4175 Date ReadyBy: Juris: H See Page 2 for I nternet: www.tigard - or.gov Notified/Method: Supptemental lnformation TYPE OF WORK REQUIRED DATA: 1 -AND 2- FAMILY DWELLING ❑ New construction ❑ Demolition Permit fees* are based on the value of the work performed. Indicate the value (rounded to the nearest dollar) of all Addition/alteration/replacement ❑ Other: equipment, materials, labor, overhead, and the profit for the CATEGORY OF CONSTRUCTION work indicated on this application. Valuation: $ ❑ 1- and 2- family dwelling commercial /industrial El Accessory building ❑ Multi- family Number of bedrooms: ❑ Master builder ❑ Other: Number of bathrooms: JOB SITE INFORMATION AND LOCATION Total number of floors: Job site address: JO n o 6-LO 130-- New dwelling area: square feet City /State /ZIP: f a/i / ©2 q Z 3 / Garage /carport area: square feet Suite/bldg. /apt. no.: Project name: 7 &74.7 PA=pii .,,,/, Covered porch area: square feet Cross street/directions to job site: Deck area: square feet Other structure area: square feet REQUIRED DATA COMMERCIAL - USE CHECKLIST Subdivision: Lot no.: Permit fees* are based on the value of the work performed. Indicate the value (rounded to the nearest dollar) of all Tax map /parcel no.: equipment, materials, labor, overhead, and the profit for the DESCRIPTION OF WORK work work indicated on this application. •� � 7 p,e)A) -RL �` Ii- ✓•/S ; �o (J Valuation: $ 2] O. i' iPit -1Aa j e j Ui A/ , 007 , Existing building area: square feet ite �L. L itio or 0<:, G / Y i l New building area: square feet ❑ PROPERTY OWNER [ ❑ TENANT Number of stories: Name: Type of construction: Address: Occupancy groups: City/State /ZIP: Existing: Phone: ( ) Fax: ( ) New: "APPLICANT ❑ CONTACT PERSON NOTICE Business name: S - C 477 -C-/ C74.— All contractors and subcontractors are required to be • Contact name: licensed with the Oregon Construction Contractors Board under ORS 701 and may be required to be licensed in the Address: jurisdiction in which work is being performed. If the City /State /ZIP: applicant is exempt from licensing, the following reasons apply: Phone: ( ) • Fax::( ) E -mail: CONTRACTOR BUILDING PERMIT FEES* Business name: w Y/f-7 f! R:� pJ.D7 // // (Please refer to fee schedule) Qy C j� /,�/ Permit fee: ! 0 g • ad Address: 9 09 > fit , 7() /bf/ / T / � , n State surcharge (12% of permit fee): ja. A6 City/State /ZIP: a z � v� 1 72 . 2 _ / ' - r FLS plan review (40% of permit fee): Phone: (593 & — ?9 .Fe-, Fax: (5 be4- - 9657 (Due upon application.) [/ CCB lic.: & '7 Total pern3itfees: // 1../. i Authorized signature: �.� /� /` Amount received: / y • 9(0 ° "'�- This permit application expires if a permit is not obtained Print name: (/ X j11#j9�/) Date: Dl ! 1 . within 180 days after it has been accepted as complete. * Fee methodology set by Tri-County Building Industry Service Board. \Building \Permits \FPS - PermitApp.doc 03/23/06 440- 4613T(11/02/COM/WEB) • ' i City of Tigard: Fire Protection Permit Checklist Page 2 - Supplemental Information 1.) ❑ New 2.) Modification to sprinkler heads only: ❑ Addition 1 -10 heads: No plan review required. llteration ❑ 11+ heads: Plan review required. ❑ Repair Number of sprinkler heads: ID Additional description of work: Type of System ;(Complete,A, B, C or,D as,'applicable) ..' A, . ':. 4 A..) Comrne'rcial Sprinkler , ❑ Wet ❑ Dry Additional Standpipes Information: Hazard Group Density Design Area K. Factor Sprinkler Project Valuation: $ Hood Project Valuation: $ C) sFtre Alarm� Submittal shall Battery Calculations ❑ Yes include: Individual Component ❑ Yes Cut Sheets Fire Alarm Project Valuation: $ 1 D) Residential Sprinkler (StandAlone System),. ` Square Footage: Permit Fee: 0 to 2,000 $187.50 2,001 to 3,600 $232.50 3,601 to 7,200 $292.50 7,201 and greater $381.50 Sprinkler Project Square Footage: sq. ft. Firc Protection Permit 5 5 Project valuation subtotal (see A, B & C above): $ Permit fee based on project valuation (see fee schedule): $ Permit fee based on square footage (see D above): $ State Surcharge (12% of permit fee): $ FLS Plan Review (40% of permit fee): $ TOTAL: $ Plan review requires a completed application and 2 sets of plans at submittal. Plan review fees are required at submittal. "New" fire protection systems require that plans bear the original seal of an Oregon licensed fire suppression engineer, or NICET level "3" technicians. http: / /www.ci.tigard.or.us/ city_ hall / departments /cd /docs /FPS- PermitApp.doc 2