Permit - ,
CITY OF TIGARD BUILDING PERMIT
PE RMIT #: BUP2006 00152
A k DEVELOPMENT SERVICES DATE ISSUED: 5/26/2006
4.41-, '_ 13125 SW Hall Blvd., Tigard, OR 97223 503 - 639 -4171
/U 83/ PARCEL: 2S110AA -01500
SITE ADDRESS: 10711 SW CANTERBURY LN BLDG 5 ZONING: R -12
SUBDIVISION: CANTERBURY CREST CONDOS LOT: 010 JURISDICTION: TIG
Project Description: Building 5, fire alarm for new 6 unit condominium. Addresses: Unit 1 through 6.
REISSUE: FLOOR AREAS EXTERIOR WALL CONSTRUCTION
CLASS OF WORK: FPS FIRST: sf N: S: E: W:
TYPE OF USE: MF SECOND: sf PROJECT OPENINGS?
TYPE OF CONST: 5 -1 HR : sf N: S: E: W:
OCCUPANCY GRP: R1 TOTAL AREA: 0 sf ROOF CONST: FIRE RET?
OCCUPANCY LOAD: BASEMENT: sf AREA SEP. RATED:
STOR: 2 HT: ft GARAGE: sf OCCU SEP. RATED: 1HR
BSMT ?: MEZZ ?: REQD SETBACKS REQUIRED
FLOOR LOAD: psf LEFT: ft RGHT: ft FIR SPKL: Y SMOK DET:Y
DWELLING UNITS: 6 FRNT: ft REAR: ft FIR ALRM : N HNDICP ACC:Y
BEDRMS: BATHS: IMP SURFACE: PRO CORR: PARKING:
VALUE: $ 1,000.00
Owner: Contractor:
CANTERBURY CREST DMS ELECTRIC INC
109 EAST 13TH STREET 8502 SE STARK ST
VANCOUVER, WA 98660 PORTLAND, OR 97216
Phone: 360 - 695 -7700 Contact #: FAX 503 - 252 -6611
PRI 503- 209 -9298
FEES Reg #: LIC 118073
Description Date Amount REQUIRED ITEMS AND REPORTS
[BUILD] Permit Fee 5/25/2006 $62.50
[TAX] 8% State Surchari 5/25/2006 $5.00
[FLS] FLS Pln Rv 5/25/2006 $25.00
Total $92.50
This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes
and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is
not started within 180 days of issuance, or if work is suspended for more than 180 days. ATTENTION: Oregon law
requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR
952-001-0010 through OAR 952 - 001 -0100. You may obtain a copy of these rings or direct questions to OUNC by
callin 03- 246 =669 or 1- 800 - 332 -2344.
Issue By: � J e Permittee Si g na re: �1 �, L
Call 503 - 639 -4175 by 7:00 a.m. for an inspection that business day.
This permit card shall be kept in a conspicuous place on the job site until completion of the project.
Approved plans are required on the job site at the time of each inspection.
ire Protection System I
I Building Permit Appli � 1 t' ErvF- - ,, y,, I OR O I I I(I:' 1 i, ' I O y l i ri . •
g Date/B 'y A d o 0 / J • i x • , — '/4 lJ
■
�1 Of Tigard Permit No.: �
13125 SW Hall Blvd., Tigard, OR 97223 Plan Review , J '+ltl��/ ���
r / wv tl I t� B : / /l� �� , Other Permit
Phone: 503.639.4171 Fax: 503.598.1960
Inspection Line: 503.639.4175 APR 2 6 2 _,�, j. I I Date
/B Da te R • . . :y: ..1111 �� See Page 2 for
Internet: www.ci.tigard.or.us Notified/Method: FORT Supplemental Information
CITY OF . i6ttU
firmib wish' 'l v NON. O REQUIRED DATA: 1- AND 2- FAMILY DWELLING
® New construction ❑ Demolition Permit fees* are based on the value of the work performed.
Indicate the value (rounded to the nearest dollar) of all
❑ Addition/alteration/replacement ❑ Other: equipment, materials, labor, overhead, and the profit for the
CATEGORY OF CONSTRUCTION work indicated on this application.
❑ 1- and 2- family dwelling ❑ Commercial /industrial
Valuation: $
m
❑ Accessory building ® Multi - family Number of bedrooms:
❑ Master builder ❑ Other: Number of bathrooms:
0 3 JOB SITE INFORMATION AND LOCATION Total number of floors:
Job site address: 10fi1 Canterbury Lane New dwelling area: square feet
City /State/ZIP: Tigard, OR 97223 Garage /carport area: square feet
Suite/bldg. /apt. no.: 5 Project name: Canterbury Cres Covered porch area: square feet
Cross street/directions to job site: Hwy 99 between Macdonald and Bull MT RD Deck area: square feet
Other structure area: square feet
REQUIRED DATA: COMMERCIAL -USE CHECKLIST
Subdivision: Canterbury Place Lot no.: Permit fees* are based on the value of the work performed.
Tax map /parcel no.: WCTM 2S110AA, 1400 / 1500 Indicate the value (rounded to the nearest dollar) of all
equipment, materials, labor, overhead, and the profit for the
DESCRIPTION OF WORK work indicated on this application.
Installation of Fire Alarm Valuation: $1,000.00
Existing building area: square feet
New building area: square feet
® PROPERTY OWNER ❑ TENANT Number of stories:
Name: Canterbury Place LLC Type of construction:
Address: 109 East 13th Street Occupancy groups:
City /State/ZIP: Vancouver, WA 98660 Existing:
Phone: (503)221 -1920 Fax: (360)693 -4442 New:
® APPLICANT ® CONTACT PERSON NOTICE
Business name: Canterbury Place LLC All contractors and subcontractors are required to be
Contact name: Dave Gutschmidt licensed with the Oregon Construction Contractors Board
under ORS 701 and may be required to be licensed in the
Address: 11625 SE 5th Street jurisdiction in which work is being performed. If the
City /State /ZIP: Bellevue, WA 98005 applicant is exempt from licensing, the following reasons
apply: 1 2, 5o
Phone: (360) 695 -7700 Fax: : (360) 693-4442 N
E -mail: n 500
CONTRACTOR d -is , 00 7:92, 515'
Business n DMS Electric
BUILDING PERMIT FEES*
Address: 85 SE Stark St
Please refer to fee schedule.
City /State/ZIP: Gresham, OR 97216
Fees due upon application
Phone: (503) 209-9298 Fax:( )
--
f (1(1,0'0
Amount received
CCB lic.: 1 3
Date received:
Authorized signature: This permit application expires if a permit is not obtained
within 180 days after it has been accepted as complete.
Print name: u / -+ I Date: /� 1 * Fee methodology set by Tri -County Building Industry 4.
May 22, 2006 ®g'� � tj�
FIL .11.
S OF T1GMD
OREGON
Canterbury Place LLC
Dave Gutschmidt
11625 SE 5 Street
Bellevue, WA 98005
RE: FIRE ALARM SYSTEM /SPRINKLER WATER FLOW ALARM
Project Information - TWO STORY 6 PLEX CARRIAGE CONDOMINIUMS — BUILDING #5
Building Permit: BUP2006 -00152
Address: Occupancy Type: R -1
/, is 3 / 10711 Canterbury Lane Construction Type: V -1 hour —Sprinklered
Area: 2 Story, 7,748 Sq Ft Tenant Name: Canterbury Woods
Hazard: Light Residential
The plan review was performed under the State of Oregon Structural Specialty Code (OSSC) 1998
edition; and the Tualatin Valley Fire & Rescue Ordinance 99 -01 (TVFR99 -01) 1999 edition. The
submitted plans are approved subject to the following.
General requirements
1. A key box shall be installed within 20 feet of the main entrance. The bottom of the key box shall be
not less than 8 feet nor more than 10 feet above the walking surface unless approved by the Fire
Chief. 902.4.2 TVFR99 -01
2. Upon completion of the installation, a satisfactory test of the entire system shall be made in the
presence of the Fire Chief. All functions of the system or alteration shall be tested. 1007.3.4.1
TVFR99 -01
3. The permittee shall provide written certification to the Fire Chief that the system has been installed
in accordance with the approved plans and specifications. A copy of the completed form shall be
maintained on the premises and made available to the Fire Chief. 1007.3.4.2 TVFR99 -01.
4. Connections to the light and power service shall be on a dedicated branch circuit. The circuit and
connections shall be mechanically protected. The circuit disconnecting means shall be accessible
only to authorized personnel and shall be clearly and permanently marked FIRE ALARM
CIRCUIT CONTROL. Standard 10 -2, Section 1- 5.2.8.2, TVFR99 -01
5. Manual Fire Alarm activation devices shall be mounted in the following reach ranges:
• Forward Reach - 15 inches to 48 inches above the floor. 1109.2.3.5 OSSC
• Side Reach — 9 inches to 54 inches above the floor. 1109.2.3.6 OSSC
13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 TDD (503) 684 -2772
. . .
6. The annunciation of all zones and device identification shall be on electrically supervised initiating
circuits to the main fire alarm control panel. Alarm, supervisory and trouble signals shall be
annunciated in the main control panel and in any required remote annunciator panels by means of
an audible signal and a visual display. Such annunciation shall indicate the building, floor, zone or
other designated area from which the alarm or trouble signal originated. For the purpose of
annunciation, zoning shall be in accordance with the following:
1. When the fire- protective signaling system serves more than one building, each building shall be
considered as a separate zone.
2. Each floor of a building shall be considered as a separate zone.
3. Each section of floor of a building that is separated by area separation walls or by horizontal exits
shall be considered as a separate zone.
4. Annunciation shall be further divided into zones where deemed necessary by the authority having
jurisdiction.
5. Identification of the type of alarm, initiating devices such as manual, automatic, sprinkler water
flow, sprinkler supervisory switches, etc.. shall be separately indicated on electrically supervised
initiating circuits to the main fire alarm control unit. TVFR99 -01, section 1007.3.3.7
7. When required by chief, fire alarm systems shall be monitored by an approved central, proprietary or
remote station service or a local alarm which gives audible and visual signals at a constantly
attended location. TVFR99 -01, section 1007.3.3.6.1
Approved Plans: 1 set of approved plans, bearing the City of Tigard approval stamp, shall be
maintained on the jobsite. The plans shall be available to the Building Division inspectors throughout
all phases of construction. 106.4.2 OSSC
Premises Identification: Approved numbers or addresses shall be provided for all new buildings in
such a position as to be plainly visible and legible from the street or road fronting the property.
When submitting revised drawings or additional information, please attach a copy of the enclosed City
of Tigard, Letter of Transmittal. The letter of transmittal assists the City of Tigard in tracking and
processing the documents.
Respectfully,
Val Henzel,
Senior Plans Examiner
r
CITY OF TIGARD
BUILDING DIVISION --- ii - ii k _. PERMIT #: BUP2006-00152
13125 SW Hall Blvd., Tigard, OR 97223 - DATE ISSUED: 5/26/2006 .
Phone: (503) 639-4171
.11 '
Inspection Requests (24 Hrs.): (503) 639-4175
INSPECTION WORKSHEET FOR DATE: 10/18/2006 TIME: 7:06AM PAGE: 48
SITE ADDRESS: 10831 SW CANTERBURY LN BLDG 5 CLASS OF WORK:
SUBDIVISION: CANTERBURY CREST CONDOS • LOT #: TYPE OF USE:
PROJECT NAME: CANTERBURY CREST
DESCRIPTION: Building 5, fire alarm for new 6 unit condominium. Addresses: Unit 1 through 6.
OWNER: CANTERBURY CREST, PHONE #: 360-696-7700
CONTRACTOR: DMS ELECTRIC INC PHONE #: 503-209-9298
Inspection Request Scheduled For: Date: 10/18/2006 Pour Time:
Code # Inspection Description Confirm # Contact # Message
998 Alarm final 038406-01 503-672-2961 N
Corrections/Comments/Instructions:
- _
dIP .
PASS PARTIAL APPROVAL 1 I CANCEL 1 1 NO ACCESS
1 1 FAIL CALL FOR INSPECTION fl ADDITIONAL FEES ASSESSED
Inspector: Cjil P Date: /O / Phone #: (503) 718-2-6gr
. •