Loading...
Permit t CITY OF TGARD BUILDING PERMIT PE RMIT #: BUP2006 -00153 . .� i�; DEVELOPMENT SERVICES DATE ISSUED: 5/26/2006 13125 SW Hall B lvd., Tigard, OR 97223 503 - 639 -4171 PARCEL: 2S110AA 01500 SITE ADDRESS: 06 / SW CANTERBURY LN BLDG 6 ZONING: R -12 SUBDIVISION: CANTERBURY CREST CONDOS LOT: 010 JURISDICTION: TIG Project Description: Building 6, fire alarm for new 6 unit condominium. Addresses: Unit 1 through 6. REISSUE: FLOOR AREAS EXTERIOR WALL CONSTRUCTION CLASS OF WORK: FPS FIRST: sf N: S: E: W: TYPE OF USE: MF SECOND: sf PROJECT OPENINGS? TYPE OF CONST: 5 -1 HR : sf N: S: E: W: OCCUPANCY GRP: R1 TOTAL AREA: 0 sf ROOF CONST: FIRE RET? OCCUPANCY LOAD: BASEMENT: sf AREA SEP. RATED: STOR: 2 HT: ft GARAGE: sf OCCU SEP. RATED: 1HR BSMT ?: MEZZ ?: REQD SETBACKS REQUIRED FLOOR LOAD: psf LEFT: ft RGHT: ft FIR SPKL: Y SMOK DET:Y DWELLING UNITS: 6 FRNT: ft REAR: ft FIR ALRM : N HNDICP ACC:Y BEDRMS: BATHS: IMP SURFACE: PRO CORR: PARKING: VALUE: $ 1,000.00 Owner: Contractor: CANTERBURY PLACE LLC DMS ELECTRIC INC 109 EAST 13TH STREET 8502 SE STARK ST VANCOUVER, WA 98660 PORTLAND, OR 97216 Phone: 360- 695 -7700 Contact #: FAX 503 - 252 -6611 PRI 503- 209 -9298 FEES Reg #: LIC 118073 Description Date Amount REQUIRED ITEMS AND REPORTS [BUILD] Permit Fee 5/25/2006 $62.50 [TAX] 8% State Surcharl 5/25/2006 $5.00 [FLS] FLS Pin Rv 5/25/2006 $25.00 Total $92.50 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more than 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952 - 001 -0010 through OAR 952 - 001 -0100. You may obtain a copy of these rules or direct questions to OUNC by calling 503= 246 -66• • or 1- 800 - 332 -2344. - Issue By: i /b _ At ) ' Permittee S l � i� — � 4, CaII 503 -639 -4175 by 7:00 a.m. for an inspection that business day. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. fire Protection System Building Permit Application a� {�F {F',�1,,,'����� cA':-- v . \i 1� - *. 1 OR n1 1 Ic l', I�`I 0\ 1 . Recei ved 1 City of Tigard ate• i 1 Pen No.:6 �� ) . sl 13125 SW Hall Blvd., Tigard, OR 97223 Plan Review - ' Phone: 503.639.4171 Fax: 503.598.1960 ���,���'r, i. A Date/B : r o , a", rill Other Permit: A Inspection Line: 503.639.4175 . �i;:= ..... ` '.i Date Ready '. y: ®See Page 2 for Internet: www.ci.tigard.or.us Notified/Method: j Supplemental Information �� C � ITY OF 1`ljt t , TYPE OF V SrJ(LDal ``(- $ e/ g N I ; ,--..--, IN REQUIRED DATA: 1- AND 2- FAMILY DWELLING ® New construction ❑ Demolition Permit fees* are based on the value of the work performed. Indicate the value (rounded to the nearest dollar) of all ❑ Addition/alteration/replacement ❑ Other: equipment, materials, labor, overhead, and the profit for the CATEGORY OF CONSTRUCTION work indicated on this application. ❑ 1- and 2- family dwelling ❑ Comercial /industrial Valuation: $ m ❑ Accessory building ® Multi - family Number of bedrooms: ❑ Master builder ❑ Other: Number of bathrooms: /0 e/ 7 JOB SITE INFORMATION AND LOCATION Total number of floors: Job site address: 40689 Canterbury Lane New dwelling area: square feet City /State /ZIP: Tigard, OR 97223 Garage /carport area: square feet Suite/bldg./apt. no.: 6 Project name: Canterbury Cres Covered porch area: square feet Cross street/directions to job site: Hwy 99 between Macdonald and Bull MT RD Deck area: square feet Other structure area: square feet REQUIRED DATA: COMMERCIAL -USE CHECKLIST Subdivision: Canterbury Place Lot no.: Permit fees* are based on the value of the work performed. Tax map /parcel no.: WCTM 2S110AA, 1400 / 1500 Indicate the value (rounded to the nearest dollar) of all equipment, materials, labor, overhead, and the profit for the DESCRIPTION OF WORK work indicated on this application. Installation of Fire Alarm Valuation: $1,000 Existing building area: square feet New building area: square feet ® PROPERTY OWNER ❑ TENANT Number of stories: Name: Canterbury Place LLC Type of construction: Address: 109 East 13th Street Occupancy groups: City/State/ZIP: Vancouver, WA 98660 Existing: Phone: (503)221 -1920 Fax: (360)693 -4442 New: ® APPLICANT ® CONTACT PERSON NOTICE Business name: Canterbury Place LLC All contractors and subcontractors are required to be Contact name: Dave Gutschmidt licensed with the Oregon Construction Contractors Board under ORS 701 and may be required to be licensed in the Address: 11625 SE 5th Street jurisdiction in which work is being performed. If the City / State/ZIP: Bellevue, WA 98005 applicant is exempt from licensing, the following reasons apply. ` Phone: (3611) 695 -7700 Fax: : (360) 693 -4442 ? /� <21 E -mail: ?C Ill%%% 5 CONTRACTOR / ( ^ ' `_ 7 G Business name: DMS Electric J (, BUILDING PERMIT FEES* Address: 85(I SE Stark St Please refer to fee schedule. City /State/ZIP: Gresham, OR 97216 Fees due upon application Phone: (503) 209 -9298 Fax: ( ) CCB lic.: 3 1( 807 1, Amount received Date received: Authorized signature: a This permit application expires if a permit is not obtained '' within 180 days after it has been accepted as complete. Print name: Date:.— , / I * Fee methodology set by Tri -County Building Industry �� �.. -. �� May 22, 2006 FILE COPY CITY OF TIGARD OREGON Canterbury Place LLC Dave Gutschmidt 11625 SE 5 Street Bellevue, WA 98005 RE: FIRE ALARM SYSTEM /SPRINKLER WATER FLOW ALARM Project Information - TWO STORY 6 PLEX CARRIAGE CONDOMINIUMS — BUILDING #6 Building Permit: BUP2006 -00153 Occupancy Type: R -1 Address:/e2 $ / q .1-0689-Canterbury Area: Lane Construction Type: V -1 hour —Sprinklered 2 Story, 7,748 Sq Ft Tenant Name: Canterbury Woods Hazard: Light Residential The plan review was performed under the State of Oregon Structural Specialty Code (OSSC) 1998 edition; and the Tualatin Valley Fire & Rescue Ordinance 99 -01 (TVFR99 -01) 1999 edition. The submitted plans are approved subject to the following. General requirements 1. A key box shall be installed within 20 feet of the main entrance. The bottom of the key box shall be not less than 8 feet nor more than 10 feet above the walking surface unless approved by the Fire Chief. 902.4.2 TVFR99 -01 2. Upon completion of the installation, a satisfactory test of the entire system shall be made in the presence of the Fire Chief. All functions of the system or alteration shall be tested. 1007.3.4.1 TVFR99 -01 3. The permittee shall provide written certification to the Fire Chief that the system has been installed in accordance with the approved plans and specifications. A copy of the completed form shall be maintained on the premises and made available to the Fire Chief. 1007.3.4.2 TVFR99 -01. 4. Connections to the light and power service shall be on a dedicated branch circuit. The circuit and connections shall be mechanically. protected. The circuit disconnecting means shall be accessible only to authorized personnel and shall be clearly and permanently marked FIRE ALARM CIRCUIT CONTROL. Standard 10 -2, Section 1- 5.2.8.2, TVFR99 -01 5. Manual Fire Alarm activation devices shall be mounted in the following reach ranges: ® Forward Reach - 15 inches to 48 inches above the floor. 1109.2.3.5 OSSC ® Side Reach — 9 inches to 54 inches above the floor. 1109.2.3.6 OSSC 13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 TDD (503) 684 -2772 6. The annunciation of all zones and device identification shall be on electrically supervised initiating circuits to the main fire alarm control panel. Alarm, supervisory and trouble signals shall be annunciated in the main control panel and in any required remote annunciator panels by means of an audible signal and a visual display. Such annunciation shall indicate the building, floor, zone or other designated area from which the alarm or trouble signal originated. For the purpose of annunciation, zoning shall be in accordance with the following. 1. When the fire- protective signaling system serves more than one building, each building shall be considered as a separate zone. 2. Each floor of a building shall be considered as a separate zone. 3. Each section of floor of a building that is separated by area separation walls or by horizontal exits shall be considered as a separate zone. 4. Annunciation shall be further divided into zones where deemed necessary by the authority having jurisdiction. 5. Identification of the type of alarm, initiating devices such as manual, automatic, sprinkler water flow, sprinkler supervisory switches, etc.. shall be separately indicated on electrically supervised initiating circuits to the main fire alarm control unit. TVFR99 -01, section 1007.3.3.7 7. When required by chief, fire alarm systems shall be monitored by an approved central, proprietary or remote station service or a local alarm which gives audible and visual signals at a constantly attended location. TVFR99 -01, section 1007.3.3.6.1 Approved Plans: 1 set of approved plans, bearing the City of Tigard approval stamp, shall be maintained on the jobsite. The plans shall be available to the Building Division inspectors throughout all phases of construction. 106.4.2 OSSC Premises Identification: Approved numbers or addresses shall be provided for all new buildings in such a position as to be plainly visible and legible from the street or road fronting the property. When submitting revised drawings or additional information, please attach a copy of the enclosed City of Tigard, Letter of Transmittal. The letter of transmittal assists the City of Tigard in tracking and processing the documents. Respectfully, Val Henz , Senior Plans Examiner • -- - CITY ��U�~�� ������B�������� OF uu���mnn�� BUILDING DIVISION PERMIT #: BUP2O06'00153 ' 13125 SW Hall Blvd., Tigard, OR 97223 DATE ISSUED: SJ26/2005 Phone: (503) 639-4171 |napockmRaque�nC24Hm � Hrs.): 639~4175 , ��W� ` * � INSPECTION WORKSHEET FOR DATE: 10K18/2006 TIME: 7:08ANI PAGE: 31 SITE ADDRESS: 10819 SVVCANTERBURY LN BLDG 6 CLASS OF WORK: SUBDIVISION: CANTERBURY CREST CONDOS LOT #: TYPE OF USE: PROJECT NAME: CANTERBURY CREST DESCRIPTION: Building 6, [ire alarm for fl€tW 6 unit condominium. Addresses: Unit 1 through G. OWNER: CANTERBURY PLACE LLC, PHONE #: 380-096'77O0 ' CONTRACTOR: QIAS ELECTRIC INC PHONE #: 503'209-9298 ` Inspection Request Scheduled For: Date: 10116K2006 Pour Time: . Inspection Code # Inspection Description Confirm # Contact # Message 998 Alarm final 038406-16 603-572-2961 N Corrections/Comments/Instructions: CCD: �� PASS �� PARTIAL APPROVAL �� CANCEL [7 NO ACCESS ' . . -_ n F ^ |L CALL FOR INSPECTION || ADDITIONAL FEES ASSESSED Inspector: C-Ne Date: /10 Phone #: K503> 718-