SGN2004-00238 C ITY OF TIGARD SIGN PERMIT
I DEVELOPMENT SERVICES PERMIT #: SGN2004 -00238
- JI 13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 DATE ISSUED: 9/17/2004
PARCEL: 1S12600-00300
BUSINESS NAME: SEARS ZONE: C -G
SIGN LOCATION: 09800 SW WASHINGTON SQUARE RD SEARS JURISDICTION: TIG
APPLICANT /AGENT: MEYER SIGN CO OF OREGON, INC
.BUSINESS TAX NO:
SIGN
PERMANENT: X FREESTANDING: FREEWAY:
TEMPORARY: WALL: Y ELECTRONIC: Y
OTHER: BILLBOARD: BALLOON:
SIGN DIMENSIONS: 7' X 33' 9"
TOTAL SIGN AREA: 236 sq. ft.
WALL AREA: 7,719 sq. ft.
WALL FACE (DIRECTION): E
SIGN HEIGHT: ft.
PROJECTION FROM WALL: 11 in.
ILLUMINATION: INT
DESCRIPTION OF SIGN: Replace existing sign with new channel letters.
MATERIALS: ALUM /PLEX
EXISTING SIGNS: 1
ELECTRICAL PERMIT REQUIRED: Y
BUILDING PERMIT REQUIRED:
ADMINISTRATIVE EXCEPTIONS:
TOTAL PERMIT FEES: $ 32.00
This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of Oregon Specialty Codes
and all other applicable laws. All work will be done in accordance with approved plans. A permanent sign must be
placed within 90 days from approval date or sign permit shall expire. A temporary sign shall expire 30 days from validity
date. A balloon sign shall expire 10 days from validity date.
APPROVED BY: (mil __ Ca■►-+.4-1-..,
\
PERMITTEE SIGNATURE:
DATE: 9/17/2004
• AL
. • SIGN PERMIT APimiLIC A-,TI N
CITY OF TIGARD 13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 FAX: (503) 684 -7297
GENERAL INFORMATION
Name of Development/Project FOR STAFF USE ONLY
Site . ,i7
Address/ Street Address Permit No.: SCN o 0 4 — d v. Z 3 S
Location ggOD 1((1 if)A01/1 i F--4 - Expiration Date:
Suite /Bldg. # City /State Zip
/ / Zb 6 , q 722 3 Receipt #: c;2004
Name Approved By: . 0 a.-4—)
Date: 9 - /S " 0
Property 6 laso UV - Uo 3 co
Owner Mailing Address Suite Map/TL #:
zoning: Mu_C
City/State Zip Phone
Electrical Permit Required? ❑ Yes ❑ No
Tenant or Name
Business 4 - .fr? S Building Permit Required? ❑ Yes ❑ No
Name Rev. 2/28 /2003 is \curpin \masters \revised \sign permit app.doc
J
fit �( S ti ,-
Sign / - af2. >le
Contractor Mailing Address Suite • REQUIRED SUBMITTAL ELEMENTS
(Prior to permit / SOUS 6VJ 7 r r — (Note: applications will not be accepted
issuance, a without the required submittal elements)
copy of all City/State Zip Phone Cs-
licenses are
required if 776'472-\b 2' 7ZZ z- % -b' e� ❑ Completed Application Form
expired in the Oregon Const. Cont. Board Exp. Date
City of Tigard's License # �-- ❑ 2 Copies of Site /Plot Plan, Drawn to Scale
• database) �' �� < <' l _ 3 _ G''
(3 copies, if a building permit is required)
Proposed kt Permanent ❑ Freestanding ❑ Freeway size requirement: 8 x 11 ", or 11" x 17"
Sign ❑ Temporary ❑ Wall ❑ Electronic
(Check all that ❑ Other El Billboard ❑ B alloon ❑ 2 copies of elevations, drawn to scale
apply) (3 copies, if a building permit is required)
gel L -Eg-_ • - ® New sign? ❑ Alter to existing sign? size requirement: 8 x 11", to 24" x 36"
E;A \51
Sign Dimensions: ,
7 11- X 3 -9 ttiJ ❑ $30.00 Fee (Permanent sign, a'hy size)
Total Sign Area (sq. ft.): Z 36 2.5 ❑ $15.00 Fee (Temporary sign, any type)
Total Wall Areas ft.
Sign Data ( q' ) 71lq,0 Jurisdiction: LI City ❑ Urb
(Complete all Direction Wall Faces (circle one): NOTES:
items in this
section) N S W NE NW SE SW
Height to top of sign (feet): c--/, o Wall signs do not need to be drawn to scale,
Projection From Wall (inches): ) (� but must include dimensions of wall face and
sign placement.
Copy: - ScfJ S o Wall signs do not require site /plot plans.
Materials: At-ay4 2 p L h , o Freestanding signs over 6 ft. required a
Will sign have illumination? [g Yes ❑ No building permit.
Type: [Q Internal ❑ External o If work authorized under a sign permit has not
Are there any existing freestanding or wall signs at this been completed within ninety (90) days after
location, including wall signs that overlap a tenant spec
pace? the issuance of the permit, THE PERMIT WILL
,� BECOME NULL AND VOID.
Yes ❑ No - te '
-- L ' ,, �1 ��, .
If "yes ", a list or diagram of all sign dim: sions and •
square footage must also be submitted.
(OVER FOR SIGNATURES)
-71 lq og 5' FT
Approved
CITY OF TIGARD
11 5 1.S (.62
- Conditionally Approved i 3
)
_ , Fov only the work,as described in:
\ ...-----" PERMIT NO. Ggio/U O O- Z 38
_.------- See Letter to: Follow 1 I
Attach 1
Jc, 9 _95a0 , -CA-S 0 i‘ , i'•
i .
1 , 1
..,
1 I 4
....i
,-- ...
u.,-:.r
,--- =----.... „..--- ,,,'? _ , ,_..,,,,,,: 6 - , , , 4. , • _. , ., . - • . ., . • , ,-
, ■ ■ W .. ',/ , 1 t."1‘',4it", . . , .,
P.--, , . • ... . -
.1 . • , - I
L----- . i L - - , , i , . , . , ' 1 , :° ° • : . ' , ,
'
, 1,, ■ r ' • " °: . ' . ' ' '
!, • , (
' 1
• , . ,
. . .
• . •
•
, . •
• 4 , • • — .
, .
• , . . . '
• ' " .4 _ „ , ,
. . . ... . , ,
. .
, ... ,
. , .
,
•
,
.
' ' . ...,,,,,
f
4 ✓
Y
" '•ti a f ^` 1+.; ",� . ,a.,,+. ' w,4 a " - . 4. 7 , , ,, ".,. "x y ,i 4. A
■ u Y � 'M _ -. ". y b _ R�,. ,: " ", J ,.Y ..,�' " ' Y . ., t " f k �:.1M" '"_,... - ..
a, 9 Y n 4
b °
� t. SS
s
�
\ w . } y
1 �: E a k a a•� p'. � t a a
� •' � ' S "r> MS My �"".ww �!aw`"^"f^S` !d 4 1 ✓,
G d
J
"x ::, , -^ a , a 7 , v . ' " , , '° w ° w W a ,a ti+ ^ f k y, `�" 4 � " ^ n �^ r ' !. ^ ^ Vie' •
�, . � ar d � �' � 4., t x � „'aa� .a , v a k
�,; ?'". ... ~'a ,aP . +,. . a r ' a „ a . ”. ° P , ' �
1
7
n,
m
33' -8 11/16' - •
m .
p _ /r' I 11PAWE APPLIED TO ' � . BEFORE O'_LUG S1LVA7RIH.
.
I
I
•
•
/,.... 2 5 /L6'- . I ELECTRICAL SPECS
PERIHCIER 38' -2' 36•-3' .31' -1' 37' -5' 38' -2` 1 1 151411 VHIT£ KEON
TRANSCO H.P. TRANSF.
• - . . -OW S912PBH
A1•PS - 256
• VOLTS = 320
I i - vA1TS = 302
�� / j ° (2) CIRCUITS REQUIRED -
ir J /ij — — - -�- - ELEC OUT Or j I r ij % J ta. t 24 2" ALUM. ANGLE SHOES BOLTED. TO WALL
1 U 1 t I 58 I3 /B" x 1 1 /2 "L PLATED GRACE ¢5 BOLT
? NEON CI. l ' - '40' -7' 36' -6' 35.' -V 34' •4' 34' -6' 35' -6' 37' 40' -0' 40' -7' 36' -2`
1 iw/1 & WASHER
/ ELECTRODE
1 S9(2PBR S912PBH S912PBH S9I2PBH S9I2PBH S912PB1-4 S912PBH S912PBH S572PB14 S912PBR - 12 5 I TOGGL.E SV1TCH w/RUT3B£R BOOT
• . 256 AHP 256 AHP . 2.56 APP 2.56 APP 2.56 AMP 2.56 AHP 2.56 AHP 2.56 AMP 256 AN. 2.56 AHP • 13 29 3/8' RIVNUT
1 . I CIRCUIT t31 128AMP 129V I CIRCUIT 112 12.BAHP 120V -
14I 15 CERAMIC McMANN NEON CONNECTOR
I "7' - LLLUM. LETTERS – ELECTRICAL & MOUNTING - 15 I 5 I /a" 1.5 1NC EYE 2011 —_
•
- ALL STRUCTURE
•
0 1► 1111 / ATTACH TO LIR BACKS \ ' /ATTACH TO OTHER BRACKE�
• �; 111
O 7ip•bI Fo— 7 /(6')(V SLOT 7/g, —o-1 �. 7/76'X1' SLD7 SCALE: 1/4 " =1' –��
-.--E 1i2'e 1 „2� 1
NM nl y }
■
® 3 - - 7 /l Y ,�. s 30/07 ... ADO (.1.11 — RS C S � S -_ •
- - -. 1 r �- 7q� / _ - _ - 5/22/07 I 4�IANGE IO RANSCO KP- 1RANSi 0.R/
O �7� 0 `.. - — U I \. ' I l I 11a7E DE .R E V 1M7
.
I l l l I V { RE SIC]N COLUMN
\ �/ \. bk.„.41 a cusroeaiiacnT(ns SCARS
- 0 .-
E—
-- .-: 7RA VING GESCk1Pr CON 11.1
mil. 0 BRACKET MOUNTED TO SIGN BACK WALL MOUNTED BRACKET cays RucnoN
�' _ P 13T NTS
so“ t T -0' 1LLUNi. EEI7ERS
Q CAD Km( ]p_C1�1C I141C
i :411).
_
SH/PPINC L /ST ` �a ' ! E3LE N
SEARS`t�f11!\SCAL07XK CO�JST -W
+ ALL BIMENSIONS .> I �� -- - � 1 l
' SE I '0L( 1E13 T T 7' Ny[Hr. a!Gw. Si WS "LETT£?S lI nrrE Ci Ol U1 FASFZMDNl S]GN. CD.
11 (I IU ! 1HRU LETTERS � � APPROVED CONSTRUCTION RUCTION TG 3E VERIF 3E
i PRWIR TO DR1LL]HG " 4(6-hvIXNG SAoes uawVN KG3 Ese -<° 3750 E. DOTER DRIVE DETROIT,
NTS ANY PEN£TRATiDNS 50'.Sfi3LT I — 1 1411 4E3234 I
II JI c N .or 28z , /z iveice IA, i1�= IISHEET 1 Dr 2_ _ I