HomeMy WebLinkAboutMEC2023-00150 MEC2o23 — OotSO CO16200 sw PACtirtC k-tW`I • FICE ''.-ECF7. 111FD TRANS Submittal A 202a Prepared For: Date:May 19, 2022 CITY U !!GUARD Chipotle BU'`DID' s iA'+E jII Job Name: Chipotle Bulk Order- Prototype#3 Trane U.S. Inc. is pleased to provide the following submittal for your review and approval. Product Summary Qty Product 2 3-10 Ton R-410A PKGD Unitary Gas/Electric Rooftop (Y4C) Justin Barnes-National Accounts The attached information describes the equipment we propose to Trane U.S. Inc. dba Trane furnish for this project,and is submitted for your approval. jdbarnes©trane.com Product performance and submittal data is valid for a period of 6 445 Bryant St., Suite 5 months from the date of submittal generation.If six months or more Denver, CO 80204-4800 has elapsed between submittal generation and equipment release, Phone: (303) 228-3300 the product performance and submittal data will need to be verified. It is the customer's responsibility to obtain such verification. ©2022 Trane Technologies All rights reserved Chipotle Bulk Order-Prototype#3 Submittal 05-19-2022.docx Table of Contents Product Summary 1 3-10 Ton R-410A PKGD Unitary Gas/Electric Rooftop(Y4C) (Items Al,A2) 3 Tag Data 3 Product Data 3 Product Report 4 Mechanical Specifications 8 Dimensional Drawings 12 Weight, Clearance& Rigging 16 Accessory 18 Field Wiring 22 Field Installed Options -Part/Order Number Summary 23 3-10 Ton R-410A PKGD Unitary Gas/Electric Rooftop 23 Chipotle Bulk Order-Prototype#3 May 19,2022 Tag Data-3-10 Ton R-410A PKGD Unitary Gas/Electric Rooftop(Y4C) (Qty: 2) Item Tag(s) Qty Description Model Number Al RTU-1 1 8.5 Ton RTU YHC102F3RHA**P7C1A2A000A0000001000000000 A2 RTU-2 1 8.5 Ton RTU YHC102F3RHA**P7C1A2A000A0000001000000000 Product Data -3-10 Ton R-410A PKGD Unitary Gas/Electric Rooftop (Y4C) All Units DX cooling, gas heat High efficiency Convertible configuration 8.5 Ton 208-230/60/3 Microprocessor controls High gas heat Low Leak Econ-comp enthalpy 0-100%/BR 3p Multi speed fan Hinged panels/2 in pleated filters MERV 8 Standard condenser coil w/hail guard Through the base electrical Circuit breaker Unpowered convenience outlet Human Interface Return air smoke detector Remote Keyed Annunciator/Reset Panel for Smoke Detector(Field Installed) Unit Mounted Human Interface for Economize Fault Detection Diagnostics 14"Tall. Flat, Non-Seismic, Knockdown Roof curb (Field Installed) NOT INCLUDED: • CONTROL WIRING/POWER WIRING, PITCHED ROOF CURBS, RTU-TO-CURB WIND/SEISMIC RESTRAINTS AND WIND LOAD CALCULATIONS, DEMAND CONTROL VENTILATION/CO2 SENSING, EXTENDED WARRANTIES Equipment Submittal Page 3 of 23 Chipotle Bulk Order-Prototype#3 May 19,2022 Product Report-3-10 Ton R-410A PKGD Unitary Gas/Electric Rooftop Item: Al Qty: 1 Tag(s): RTU-1 Trane Precedent Gas/Electric Packaged Rooftop Unit Overview-YHC102F3RHA"P7C1A2A000A0000001000000000 Application Unit Size Pan ,:°i. lCis EER IEERISEER Elevation External DX cooling, Airflow Static Height Width Length Minimum Maximum gas heat 8.5 Ton Pressure 12.5 EER 14.70 0.00 ft 3400 cfm 0 H8 Oin 3.91 ft 4.44 ft 7.39 ft 1035.01b 1300.01b Unit Features Low Leak Econ-comp enthalpy F reak AM--•soon 0 1004o/BR 3p SuppiyFuWAvai MotorType Multi speed fan &" ' m�� Condenser coil protection Std condenser coil w/hail guard Hinged Service Access/Fitters Hinged pnl/2 in pltd filters MERV 3 Unit Electrical VoltageiphasMartz 208-230/60/3 ♦ ' ^MCA 42.00 A MOP 50.00 A • Controls Unit Controls Microprocessor controls Cooling Section Entering Dry Bulb 80.00E � , r Entering Wet Sub 67.00 F Gross Total 100.68 MBh Ambient Temp 90.00 F Gross Sensible 79.22 MBh Leaving Coil Dry Bulb 58.42 F Net Total 94.76 MBh Leaving Coil Wet Bulb 57.47 F Net Sensible 73.30 MBh Leaving Unit Dry Bulb 60.36 F Fan Motor Heat 5.92 MBh Leaving Unit Wet Bulb 58.21 F RNrip Charge-circuit 1 6.3 lb • .. Refrig Charge-chit 2 4.9 lb Leaving Dew Poh*56.86 F Heating Section Heat Type Gas Heat Heating Stages 2 Output HeatingCapacity 160.00 MBh Output Heating Capacity wi h Fan 165.92 MBh Nesting EAT 70.00 F Heating LAT 113.80 F Heating Term Rise 43.80 F Fan Section Type BC Plenum Type Propeller Drive Type Direct Fan Quantity 1 Evap Fan FI.A 7.30 A Drive Type Direct �av Airflow 3400 cfm Outdoor Motor Power 0.71 kW Design ESP 0.800 in H2O Condenser Fan FLA 4.00 A Component SP 0.740 in H2O Total SP 1.540 in H2O Supply Motor Horsepower 2.750 hp indoor Motor Operating Power 2.07 bhp indoor Motor Power 1.54 kW indoor RPM 1438 rpm Compressor Section Accessories Power 6.18 kW Roof curb yes Circuit 1 RLA 15.60 A Circuit 2 RLA 10.00 A Equipment Submittal Page 4 of 23 Chipotle Bulk Order-Prototype#3 May 19, 2022 Product Report-3-10 Ton R-410A PKGD Unitary Gas/Electric Rooftop Item: Al Qty: 1 Tag(s): RTU-1 Acoustics Sound Path 83 Hz 125 Hz- 250 Hz 500 Hz ' 1'kHz 2 kHz 4 kHz 8 kHz Ducted Discharge 79 dB 92 dB 83 dB 84 dB 79 dB 73 dB 74 dB 88 dB Ducted Inlet 80 dB 76 dB 76 dB 68 dB 55 dB 56 dB 57 dB 47 dB Outdoor Noise 83 dB 85 dB 85 dB 86 dB 84 dB 78 dB 74 dB 70 dB Note Ducted Inlet and Ducted Discharge Sound Power Levels are in accordance with AHRI 260. Note Outdoor Sound Power Levels are in accordance with AHRI 270. Equipment Submittal Page 5 of 23 Chipotle Bulk Order-Prototype#3 May 19,2022 Product Report-3-10 Ton R-410A PKGD Unitary Gas/Electric Rooftop Item: A2 Qty: 1 Tag(s): RTU-2 Trane Precedent Gas/Electric Packaged Rooftop Unit Overview-YHC102F3RHA"P7C1A2A000A0000001000000000 Application Unit Size } K., EER MERfSL*ER Elevation External X Airflow Static Height Width Length Minimum Maximum O cooling.heat 8.5 Ton Pressure 12.5 EER 14.70 0.00 ft gas3400 cfrn 0. rn 3.91 ft 4.44 ft 7.39 ft 1035.0 lb 1300.0 lb Unit Features Fresh Air 9ehetl n Low Leak Eton comp enthalpy r 0-100%/BR 3p SupplyFenlDrlvaf MotorType Multi speed fan g Condenser coil protection Std condenser coil wlhall guard Hinged Service Hinged pnl/2 in ph d fitters MERV S c J- Unit Electrical Voltage/phase/harts 208-230/60/3 MCA 42.00 A MOP 50.00 A Controls Unit Controls Microprocessor controls Cooling Section Entering Dry Bub 80.00 F Entering Wet Bulb 67.00 F Gross Total 100.68 MBh Ambient Temp 90.00 F Gross Sensible 79.22 MBh Leaving Con Dry Bulb 58.42 F Net Total 94.76 MBh Leaving Coil Wet Bulb 57.47 F Net Sensible 73.30 MBh Leaving Unit Dry Bulb 80.36 F Fan Motor Heat 5.92 MBh Leaving Unit Wet Bunn 58.21 F Rehig Charge-eke-tilt 1 6.3 lb `,,,. �, ,. �. 'Raffia Charge-circuit3 as lb Leaving Dew Point 56.86 F Heating Section Heat Type Gas Heat Heating Stages 2 Output Heating Capacity 160.00 MBh Output Heating Capacity with Fan 165.92 MBh Heating EAT 70.00 F Heating LAT 113.80 F Heating Temp Rise 43.80 F Fan Section Type BC Plenum Type Propeller Drive Type Direct Fan Quantity 1 Evap Fan FLA 7.30 A Drive Type Direct ` '."�.44.-i4..,.x_: .FV .,s a.,, Airflow 3400 cfm Outdoor Motor Power 0.71 kW Design ESP 0.800 in H2O Condenser Fan FLA 4.00 A Component SP 0.740 in H2O Total SP 1.540 in H2O Supply Motor Horsepower 2.750 hp Indoor Motor Operating Power 2.07 bhp Indoor Motor Power 1.54 kW indoor RPM 1438 rpm Compressor Section Accessories Power 6.18 kW Roof curb yes Circuit 1 RLA 15.60 A Circuit 2 RLA 10.00 A Equipment Submittal Page 6 of 23 Chipotle Bulk Order-Prototype#3 May 19,2022 Product Report-3-10 Ton R-410A PKGD Unitary Gas/Electric Rooftop Item: A2 Qty: 1 Tag(s): RTU-2 Acoustics Sound Path 83 Hz 125 Hz 250 Hz 500 Hz I kHz 2 kHz 4 kHz 8 kHz Ducted Discharge 79 dB 92 dB 83 dB 84 dB 79 dB 73 dB 74 dB 66 dB Ducted Inlet 80 dB 76 dB 76 dB 68 dB 55 dB 56 dB 57 dB 47 dB Outdoor Noise 83 dB 85 dB 85 dB 86 dB 84 dB 78 dB 74 dB 70 dB Note:Ducted Inlet and Ducted Discharge Sound Power Levels are in accordance with AHRI 260. Note Outdoor Sound Power Levels are in accordance with AHRI 270. Equipment Submittal Page 7 of 23 Chipotle Bulk Order-Prototype#3 May 19,2022 Mechanical Specifications -3-10 Ton R-410A PKGD Unitary Gas/Electric Rooftop Item: Al,A2 Qty: 2 Tag(s): RTU-1, RTU-2 General The units shall be convertible airflow.The operating range shall be between 115°F and 0°F in cooling as standard from the factory for units with microprocessor controls. Operating range for units with electromechanical controls shall be between 115°F and 40°F. Cooling performance shall be rated in accordance with ARI testing procedures.All units shall be factory assembled, internally wired,fully charged with R-410A, and 100 percent run tested to check cooling operation, fan and blower rotation, and control sequence before leaving the factory.Wiring internal to the unit shall be colored and numbered for simplified identification. Units shall be cULus listed and labeled, classified in accordance for Central Cooling Air Conditioners. Casing Unit casing shall be constructed of zinc coated, heavy gauge, galvanized steel. Exterior surfaces shall be cleaned, phosphatized, and finished with a weather-resistant baked enamel finish. Unit's surface shall be tested 672 hours in a salt spray test in compliance with ASTM B117. Cabinet construction shall allow for all maintenance on one side of the unit. Service panels shall have lifting handles and be removed and reinstalled by removing two fasteners while providing a water and air tight seal.All exposed vertical panels and top covers in the indoor air section shall be insulated with a cleanable foil-faced, fire-retardant permanent, odorless glass fiber material. The base of the unit shall be insulated with 1/8",foil-faced, closed-cell insulation.All insulation edges shall be either captured or sealed. The unit's base pan shall have no penetrations within the perimeter of the curb other than the raised 1 1/8" high downflow supply/return openings to provide an added water integrity precaution, if the condensate drain backs up.The base of the unit shall have provisions for forklift and crane lifting, with forklift capabilities on three sides of the unit. Unit Top The top cover shall be one piece construction or,where seams exist, it shall be double-hemmed and gasket-sealed. The ribbed top adds extra strength and enhances water removal from unit top. Two-Inch Pleated Filters 2" pleated media filters shall be available on all models. Compressors All units shall have direct-drive, hermetic, scroll type compressors with centrifugal type oil pumps. Motor shall be suction gas-cooled and shall have a voltage utilization range of plus or minus 10 percent of unit nameplate voltage. Internal overloads shall be provided with the scroll compressors. Dual compressors are outstanding for humidity control, light load cooling conditions and system back-up applications. Dual compressors are available on 7%-10 ton models and allow for efficient cooling utilizing 3-stages of compressor operation for all high efficiency models. Indoor Fan The following units shall be equipped with a direct drive plenum fan design (T/YSC120F,T/YHC074F, T/YHC092F,T/YHC102F, 120F). Plenum fan design shall include a backward-curved fan wheel along with an external rotor direct drive variable speed indoor motor. All plenum fan designs will have a variable speed adjustment potentiometer located in the control box. 3 to 5 ton units (high efficiency 3-phase with optional motor)are belt driven, FC centrifugal fans with adjustable motor sheaves. 3 to 5 ton units (standard and high efficiency 3-phase) have multispeed, direct drive motors.All 6 to 8%ton units(standard efficiency)shall have belt drive motors with an adjustable idler-arm assembly for quick-adjustment to fan belts and motor sheaves.All motors shall be thermally protected.All 10 tons, 6 ton (074), 7%to 8%(high efficiency) units have variable speed direct drive motors.All indoor fan motors meet the U.S. Energy Policy Act of 1992 (EPACT). Outdoor Fans The outdoor fan shall be direct-drive, statically and dynamically balanced, draw-through in the vertical discharge position. The fan motor shall be permanently lubricated and shall have built-in thermal overload protection. Multi-Speed Indoor Fan System Multi-speed indoor fan system is designed for use in applications for meeting the minimum requirement of CA Title 24. This system incorporates a multi-speed fan control to change the speed of the fan to 66%of full airflow based off of compressor stages. Equipment Submittal Page 8 of 23 Chipotle Bulk Order-Prototype#3 May 19, 2022 Evaporator and Condenser Coils Internally finned, 5/16"copper tubes mechanically bonded to a configured aluminum plate fin shall be standard. Evaporator coils are standard for all 3 to 10 ton standard efficiency models. Microchannel condenser coils are standard for all 3 to 10 ton standard efficiency models and 4, 5, 6, 7.5, 8.5 ton high efficiency models. The microchannel type condenser coil is not offered on the 4 and 5 ton dehumidification model. Due to flat streamlined tubes with small ports, and metallurgical tube-to-fin bond, microchannel coil has better heat transfer performance. Microchannel condenser coil can reduce system refrigerant charge by up to 50% because of smaller internal volume, which leads to better compressor reliability. Compact all-aluminum microchannel coils also help to reduce the unit weight. These all aluminum coils are recyclable. Galvanic corrosion is also minimized due to all aluminum construction. Strong aluminum brazed structure provides better fin protection. In addition,flat streamlined tubes also make microchannel coils more dust resistant and easier to clean. Coils shall be leak tested at the factory to ensure the pressure integrity. The evaporator coil and condenser coil shall be leak tested to 600 psig. The assembled unit shall be leak tested to 465 psig. The condenser coil shall have a patent pending 1+1+1 hybrid coil designed with slight gaps for ease of cleaning. A plastic, dual-sloped, removable and reversible condensate drain pan with through-the- base condensate drain is standard. Tool-less Hail Guards Tool-less, hail protection quality coil guards are available for condenser coil protection. Controls Unit shall be completely factory-wired with necessary controls and contactor pressure lugs or terminal block for power wiring. Unit shall provide an external location for mounting a fused disconnect device.A choice of microprocessor or electromechanical controls shall be available. Microprocessor controls provide for all 24V control functions. The resident control algorithms shall make all heating, cooling, and/or ventilating decisions in response to electronic signals from sensors measuring indoor and outdoor temperatures. The control algorithm maintains accurate temperature control, minimizes drift from set point, and provides better building comfort. A centralized microprocessor shall provide anti-short cycle timing and time delay between compressors to provide a higher level of machine protection. 24-volt electromechanical control circuit shall include control transformer and contactor High Pressure Control All units include High Pressure Cutout as standard. Phase monitor Phase monitor shall provide 100% protection for motors and compressors against problems caused by phase loss, phase imbalance, and phase reversal. Phase monitor is equipped with an LED that provides an ON or FAULT indicator. There are no field adjustments. The module will automatically reset from a fault condition. Refrigerant Circuits Each refrigerant circuit offer thermal expansion valve as standard. Service pressure ports, and refrigerant line filter driers are factory-installed as standard.An area shall be provided for replacement suction line driers. Gas Heating Section The heating section shall have a progressive tubular heat exchanger design using stainless steel burners and corrosion resistant steel throughout.An induced draft combustion blower shall be used to pull the combustion products through the firing tubes. The heater shall use a direct spark ignition (DSI) system. On initial call for heat, the combustion blower shall purge the heat exchanger for 20 seconds before ignition After three unsuccessful ignition attempts, the entire heating system shall be locked out until manually reset at the thermostat/zone sensor. Units shall be suitable for use with natural gas or propane (field-installed kit) and also comply with the California requirement for low NOx emissions (Gas/Electric Only). Hinged Access Doors Sheet metal hinges are available on the Filter/Evaporator, Supply Fan/Heat, and the Compressor/Control Access Doors. Powered or Unpowered Convenience Outlet This is a GFCI, 120v/15amp, 2 plug, convenience outlet, either powered or unpowered. When the convenience outlet is powered, a service receptacle disconnect will be available.The convenience outlet is powered from the line side of the disconnect or circuit breaker, and therefore will not be affected by the position of the disconnect or circuit breaker. This option can only be ordered when the Through the Base Electrical with either the Disconnect Switch or Circuit Breaker option is ordered. Equipment Submittal Page 9 of 23 Chipotle Bulk Order-Prototype#3 May 19,2022 Plenum Fan The following unit shall be equipped with a direct drive plenum fan design (all 10 tons and 7.5-8.5 ton high efficiency units). Plenum fan design shall include a backward-curved fan wheel along with an external rotor direct drive variable speed indoor motor. All plenum fan designs will have a variable speed adjustment potentiometer located in the control box. Through the Base Electrical Access An electrical service entrance shall be provided allowing electrical access for both control and main power connections inside the curb and through the base of the unit. Option will allow for field installation of liquid-tight conduit and an external field-installed disconnect switch. Through the Base Electrical with Circuit Breaker This option is a thermal magnetic, molded case, HACR Circuit Breaker with provisions for through the base electrical connections. The circuit breaker will be installed in a water tight enclosure in the unit with access through a swinging door. Wiring will be provided from the switch to the unit high voltage terminal block. The circuit breaker will provide overcurrent protection, be sized per NEC and UL guidelines, and be agency recognized by UL/CSA. Supply and/or Return Air Smoke Detector Smoke detector shall be factory installed photoelectric smoke detector mounted in the return air section (with or without the economizer or motorized damper option), AND/OR in the supply air fan compartment. The detector will be wired for continuous power whenever the unit is energized. Upon detection of smoke,the detector will shut down all unit operations. Local codes may dictate the location of detectors. Note: Due to the shipping position of the economizer or motorized damper, the return air smoke detector will not be completely factory installed. The wiring harness for the detector will be routed and tied off in the fan compartment for shipping. The smoke detector and barometric damper hood will also be installed in a shipping position in the fan compartment. Accessory -Roof Curb The roof curb shall be designed to mate with the unit's downflow supply and return and provide support and a water tight installation when installed properly. The roof curb design shall allow field fabricated rectangular supply/return ductwork to be connected directly to the curb. Curb design shall comply with NRCA requirements. Curb shall be shipped knocked down for field assembly and shall include wood nailer strips. Supply, Return,and Plenum Air Smoke Detector With this option installed, if smoke is detected, all unit operation will be shut down. Reset will be manual at the unit. In order for the supply air smoke detector or return air smoke detector to properly sense smoke in the supply air stream or the return air stream,the air velocity entering the smoke detector unit must be between 500 -4000 feet per minute. Equipment covered in this manual will develop an airflow velocity that falls within these limits over the entire airflow range specified in the evaporator fan performance table. Supply and/or Return Smoke Detectors may not be used with the Plenum Smoke Detector. ***ATTENTION*** For installation in SCAQMD only:This furnace does not meet the SCAQMD Rule 1111 14 ng/J NOx emission limit, and thus is subject to a mitigation fee of up to$450. This furnace is not eligible for the Clean Air Furnace Rebate Program: www.CleanAirFurnaceRebate.com. Sequence of Operation (if applied in a SINGLE-ZONE CONSTANT-VOLUME SYSTEM or a CHANGEOVER BYPASS SYSTEM) B. SINGLE-ZONE CONSTANT-VOLUME SYSTEM 1.OCCUPIED HEAT/COOL: The RTU shall operate the supply fan continuously and modulate(or cycle) compressors, modulate (or stage) heat, and/or enable airside economizing to maintain zone temperature at setpoint. The OA damper shall open to bring in the required amount of ventilation. 2. MORNING WARM-UP/PRE-COOL: The RTU shall operate the supply fan and modulate(or cycle) compressors or modulate (or stage) heat to raise/lower zone temperature to its occupied setpoint.The OA damper shall remain closed, unless economizing. D. CHANGEOVER BYPASS SYSTEM Equipment Submittal Page 10 of 23 Chipotle Bulk Order-Prototype#3 May 19,2022 1. OCCUPIED HEAT/COOL: Each VAV terminal shall use pressure-independent control, with airflow measurement, to vary primary airflow to maintain zone temperature at its occupied setpoint.The RTU shall modulate the bypass damper to maintain duct static pressure at setpoint and modulate (or cycle) compressors, modulate(or stage) heat, and/or enable airside economizing based on current zone cooling/heating demands. The OA damper shall open to bring in the required amount of ventilation. 2. MORNING WARM-UP/PRE-COOL: Each VAV terminal unit shall vary primary airflow to raise/lower zone temperature to its occupied setpoint. The RTU shall modulate the bypass damper to maintain duct static pressure at setpoint and modulate (or cycle)compressors or modulate (or stage) heat based on current zone cooling/heating demands. The OA damper shall remain closed, unless economizing. 3. COOLING/HEATING CHANGEOVER LOGIC: The System Controller shall determine the overall system cooling/heating mode based on"voting" from each zone. When the majority of zones require cooling, the RTU shall operate in cooling mode and any zone that requires heating shall reduce primary airflow to minimum. When the majority of zones require heating, the RTU shall operate in heating mode and any zone that requires cooling shall reduce primary airflow to minimum. Equipment Submittal Page 11 of 23 Chipotle Bulk Order-Prototype#3 May 19,2022 Dimensional Drawings -3-10 Ton R-410A PKGD Unitary Gas/Electric Rooftop Item:Al,A2 Qty: 2 Tag(s): RTU-1, RTU-2 TOP PANEL EVAPORATOR SECTION ACCESS PANEL CONDENSER FAN CONDENSATE DRAIN(ALT) I 3/4"-14 NPT DIA.HOLE w�`1`y, ``gyp ON DENSER COIL 41/412\ 27 5/8„ 4./ NIT CONTROL WIRE 7/8"DIA.HOLE 111111 4 SERVICENITPOWER GAUGEWIRE PORT ACCESS 1 3/8"DIA.HOLE 47 7!8" , i� 112-NPT GAS CONNECTION (80MBH 8 120MBH) 314'NPT GAS CONNECTION ONTROLAND COMPRESSOR ACCESS PANEL (150MBH,200MBH 8 250MBH) PACKAGED GAS/ELECTRICAL THROUGH THE ISOMETRIC VIEW BASE CONDENSATE 4 1/8' 27 5/8"1 - NOTES: i.THRU-THE-BASE ELECTRICAL IS NOT STANDARD ON ALL UNITS. 2.VERIFY ALL DIMENSIONS WITH INSTALLER DOCUMENTS BEFORE INSTALLATIONr__F__, vtoi SUPPLY����``r i 33" 32 1/8" RETURN --1._- --I ---.1 - 17 1/2" - 9 7/8" - 17 1/2" - .-3 5/8" PLAN VIEW UNIT DIMENSION DRAWING 46718' HORIZONTAL RETURN 321/4" AIR FLOW 23 7/8" SUPPLY L . 24 I12" 11111 �mm)♦-m(a)♦�M 4 3/4" 12. " 5 5/8 �IL���� 4 - 191/4" 41 93/8" - 163/4' - J.__37/8° II 4 1/4" - • CONDENSATE 5518" - 1 5/8" 7 5+8' - - PACKAGED GAS/ELECTRICAL - 53 1/4" DIMENSION DRAWING Equipment Submittal Page 12 of 23 • Chipotle Bulk Order-Prototype#3 May 19,2022 Dimensional Drawings -3-10 Ton R-410A PKGD Unitary Gas/Electric Rooftop Item: Al,A2 Qty: 2 Tag(s): RTU-1, RTU-2 it(**76-1)))) ne RETURN 3!4"-14 DIA HOLE CONDENSATE DRAIN 27 5/8" 4 3!4" ISOMETRIC-PACKAGED COOLING Equipment Submittal Page 13 of 23 Chipotle Bulk Order-Prototype#3 May 19, 2022 Dimensional Drawings -3-10 Ton R-410A PKGD Unitary Gas/Electric Rooftop Item: Al,A2 Qty: 2 Tag(s): RTU-1, RTU-2 \\ Skt,,,,,s, 11114-4 o PANEL 0 ACCESS SIDE CONDENSER COL SIDE CONDENSER COIL SIDE )�`__. l J THROUGH THE BASE ELECTRICAL (SEE NOTE 1 AND 2) 2 C 4 J 3 3/4" / T- , THROUGHTHE BASE CONDENSATE 5 7/8" _ -- - 5" NOTES: 1 THRU-THE-BASE GAS AND ELECTRICAL IS NOT STANDARD. PANEL VERIFY OPTION IN PRODUCT DATA IN THIS DOCUMENT. ACCESS SIDE 2.VERIFY WEIGHT,CONNECTION,OPTION CONFIGURATION AND ALL DIMENSION WITH INSTALLER DOCUMENTS BEFORE INSTALLATION THRU THE BASE ELECTRICAL PLAN/ISO VIEW DRAWING Equipment Submittal Page 14 of 23 Chipotle Bulk Order-Prototype#3 May 19, 2022 Dimensional Drawings-3-10 Ton R-410A PKGD Unitary Gas/Electric Rooftop Item:Al,A2 Qty: 2 Tag(s): RTU-1, RTU-2 ELECTRICAL/GENERAL DATA GENERAL 2H4 6) HEATING PERFORMANCE Model: YHC102F Oversized Motor HEATING-GENERAL DATA Unit Operating Voltage: 187-253 MCA: N/A Unit PnmaryVolt Heating Model: High age: 208 MFS: N/A HeatngInput BTU): H0Q60Dn40,000 6 Und Hertz: !SD Unit Secondary Voltage 230 MCB: N/A Heating Output(BTU): 1600,000/112,000 Unit Phase: 3 No.BumeIs: 4 No.Stages 2 EER 12.5 Standard Motor Field Installed Oversized Motor Gas Inlet Pressure MCA '42.0 MCA N/A Natural Gas(Mn/Max): 4 1/2"/14" MFS: 50.0 MFS: N/A LPGrl in/Max) 11.714" MCB: 50.0 MCB: N/A Gas Pipe Connection Size: 3/4" INDOOR MOTOR Standard Motor Oversized Motor Field Installed Oversized Motor Number 1 Number: Number: N/A Horsepower: 2.75 Horsepower. Horsepower N/A Motor Speed(RPM): — Motor Speed(RPM): Motor Speed(RPM): N/A Phase 3 Phase Phase N/A Full Load Amps: 7.3 Full Load Amps: Full Load Amps: N/A Locked Rotor Amps: -- Locked Rotor Amps: Locked Rotor Amps: N/A COMPRESSOR Circuit 112 OUTDOOR MOTOR Number: 2 Number. 1 Horsepower: 4.5/2.4 Horsepower: 0.75 Phase: 3 Motor Speed(RPM): 1100 Rated Load Amps: 15.6/10.0 Phase: 1 Locked Rotor Amps: -- Full Load Amps: 4.0 POWER EXHAUST ACCESSORY (37) FILTERS REFRIGERANT (2) (Field Installed Power Exhaust) Type R-410 Phase: WA Type: Throwaway Factory Charge Horsepower N/A Furnished: Yes Motor Speed(RPM): N/A Number 4 Circuit 41 6.3 l Full Load Amps: N/A Recommended 20"x25"x2" Circuit#2 4.9 lb Locked Rotor/4nps: N/A NOTES: I.Maximum(HACR)Circuit Breaker sting is for installations in the United States only. 2.Refrigerant charge is an approximate value.For a more precise value,see unit nameplate and service instructions. 3.Value does not include Power Exhaust Accessory. 4.Value includes oversized motor. 5.Value does not include Power Exhaust Accessory 6.EER is rated at AHRI conditions and in accordance with DOE test procedures. 7.Installation of this power exhaust kit will affect unit level MCA and could affect MOP sizing havng a direct impact on existing field wiring and unit proteclron devices.The change in MCAMI OP is the sole responsanty of the field installing party.Trene will not issue new nameplates as a result of this power exhaust accessory installation.FLA of the power exhaust kit option must be added to the MCA of the unit for building supply conductor sting determination. Equipment Submittal Page 15 of 23 Chipotle Bulk Order-Prototype#3 May 19,2022 Weight, Clearance& Rigging -3-10 Ton R-410A PKGD Unitary Gas/Electric Rooftop Item: Al,A2 Qty: 2 Tag(s): RTU-1, RTU-2 INSTALLED ACCESSORIES NET WEIGHT DATA ACCESSORY WEIGHTS ECONOMIZER 91.0 lb MOTORIZED OUTSIDE AIR DAMPER C D MANUAL OUTSIDE AIR DAMPER (({ BAROMETRIC RELIEF (( OVERSIZED MOTOR i- - a ` BELT DRIVE MOTOR r r iffef •tlN % POWER EXHAUST ���1`�dfl/gJ THROUGHT THE BASE ELECTRICAL/GAS(FIOPS) 13.0 lb , - .—___—+v ,I�/J UNIT MOUNTED CIRCUIT BREAKER(HOPS) 5.0 lb UNIT MOUNTED DISCONNECT(FIOPS) POWERED CONVENIENCE OUTLET(FIOPS) 0/1('''', _ l0 HINGED DOORS(FIOPS) 12.0lb HAIL GUARD 30.0 lb SMOKE DETECTOR,SUPPLY/RETURN 7.0 lb PACKAGED GAS/ELECTRICAL NovAR CONTROL CORNER WEIGHT STAINLESS STEEL HEAT EXCHANGER REHEAT ROOF CURB 78.0Ib BASIC UNIT WEIGHTS CORNER WEIGHTS CENTER OF GRAVITIY SHIPPING NET AO 341.0Ib © 253.0Ib (E)LENGHT (F)WIDTH 1133.0Ib 1035.0Ib O 236.0 lb DO 205.0 lb 49' 23' NOTE: 1. All weights are approximate. 2 Weights for options that are not list refer to Installation guide. 3. The actual weight are listed on the unit nameplate. t 4. Refer to unit nameplate and installation guide for weights before scheduling transportation and instalation of unit. 5. The weight shown represents the typical unit operating weight for the configuration selected.Estimated at /-10%of the nameplate weight.. 6. Verify weight,connection,and all dimension with installer documents betore nslallatmn. 7. Corner weights are given for information only. 8. Net/Shipping weight of optional accessories should be added to uni weight when ordering factory or field \ installed accessories. 4 1 E `Noi „..„,.,,,i��� ,, ' ' 9"' F *:1\,,,.,,:,',„17°' .t' ‘-'7- , PACKAGED GAS/ELECTRICAL RIGGING AND CENTER OF GRAVITY Equipment Submittal Page 16 of 23 • Chipotle Bulk Order-Prototype#3 May 19, 2022 Weight, Clearance& Rigging -3-10 Ton R-410A PKGD Unitary Gas/Electric Rooftop Item: Al,A2 Qty: 2 Tag(s): RTU-1, RTU-2 CLEARANCE FROM TOP OF UNIT 77 CLEARANCE 36" CLEARANCE 48" ____D ' 7 tit H \ RETURN Q. s , DOWNFLOW CLEARANCE 36" HORIZONTAL CLEARANCE 18" CLEARANCE 36" PACKAGED GAS/ELECTRIC CLEARANCE ROOF OPENING I I UNIT OUTLINE ----NNH I 46" 53 1/4" I I _i_ 46 ---] - 88 5/8" PACKAGED GAS/ELECTRIC DOWNFLOW TYPICAL ROOF OPENING Equipment Submittal Page 17 of 23 Chipotle Bulk Order-Prototype#3 May 19,2022 Accessory -3-10 Ton R-41OA PKGD Unitary Gas/Electric Rooftop Item: Al,A2 Qty: 2 Tag(s): RTU-1, RTU-2 004411.401 / / \ / / ____ ____ N. ,,,, T\___ \ ____ \-- 2,3/8" 14 sir SWING DIAMETER-HINGED DOOR(S)OPTION ACCESSORY Equipment Submittal Page 18 of 23 Chipotle Bulk Order-Prototype#3 May 19, 2022 Accessory-3-10 Ton R-410A PKGD Unitary Gas/Electric Rooftop Item: Al,A2 Qty: 2 Tag(s): RTU-1, RTU-2 NOTES RETURN OPENING I VERIFY WEIGHT,CONNECTION,AND ALL DIMENSION WITH INSTALLER DOCUMENTS BEFORE INSTALLATION SUPPLY OPENING 1 11/16"+- 7/16"--- 8 5/8" +-18 7/16"-.• /1 11/16" 34 3/8" 34 3/8" 46 7/16" ,,� 2" 83 15t16" 9 13/16" 1 4" 14" L.- 7,16"--] 84 1/2" ROOF TOP CURB(BAYCURB043) ACCESSORY Equipment Submittal Page 19 of 23 Chipotle Bulk Order-Prototype#3 May 19,2022 Accessory -3-10 Ton R-410A PKGD Unitary Gas/Electric Rooftop Item: Al,A2 Qty: 2 Tag(s): RTU-1, RTU-2 Downlbw Dud Connections-Field Fabricated AI Flanges- 1 1/4" ,..-"--- -'17 3l4" <--.33 3/4' IIIIIIIIIIIII' ,,,------.-'''''''17 3/4' 33 3 4 444444444N4‘1111S �il * 40011, i ACCESSORY-DUCT CONNECTIONS Equipment Submittal Page 20 of 23 $ Chipotle Bulk Order-Prototype#3 May 19, 2022 Accessory -3-10 Ton R-410A PKGD Unitary Gas/Electric Rooftop Item: Al,A2 Qty: 2 Tag(s): RTU-1, RTU-2 ks,.„.„,..,.. :::]‘ CONOMIZER HOOD 1.1010/ BAROMETRIC RELIEF HOOD CONOMIZER HOOD . ..---- Wow 38 1i2" - LI„, o 7" • 00 00 . 11 1/8" 27 7/8" LOW LEAK ECONOMIZER HOOD ACCESSORY Equipment Submittal Page 21 of 23 Chipotle Bulk Order-Prototype#3 May 19,2022 Field Wiring -3-10 Ton R-410A PKGD Unitary Gas/Electric Rooftop Item: Al,A2 Qty: 2 Tag(s): RTU-1, RTU-2 I Lt L2 L3 NTa, 11 I, °!. I I C71 o ZONE SENSOR WIRE TABLE WIRE SIZE MAXIMUM WIRE LENGTH 22 GAUGE 1800' 20 GAUGE 3000' 18 GAUGE 4500' 16 GAUGE 7200" 14 GAUGE 11700' NOTE: 1.Nt wung and devices shown dashed to be supplied and installed by the customer in accordance with national and local electrical codes. 2.Low voltage control wing must not be fun in conduit with power wiring. Equipment Submittal Page 22 of 23 Chipotle Bulk Order-Prototype#3 May 19, 2022 Field Installed Options -Part/Order Number Summary This is a report to help you locate field installed options that arrive at the jobsite. This report provides part or order numbers for each field installed option, and references it to a specific product tag. It is NOT intended as a bill of material for the job. Product Family -3-10 Ton R-410A PKGD Unitary Gas/Electric Rooftop Item Tag(s) Qty Description Model Number Al RTU-1 1 8.5 Ton RTU YHC102F3RHA**P7C1A2A 000A0000001000000000 A2 RTU-2 1 8.5 Ton RTU YHC102F3RHA**P7C1A2A 000A0000001000000000 Field Installed Option Description Part/Ordering Number Roof curb BAYCURB043A Equipment Submittal Page 23 of 23