Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
FPS2024-00178 (3)
FPS 2o2-4-0O11 '' 1Q200 SW PAUHC t-F01`1, STE. 5 SWIFT FIRE PROTECTION ‘ FF! E9cO ' ' Fire Protection Material AMERICA' S BEST TIGARD 16200 SW PACIFIC HWY, STE S, TIGARD, OR 97224 Swift Fire Protection Job# 24080 2017 NW Vaughn St. #10087 Portland, OR 97296 Phone:360-605-1133 SV*/ IFT FIRE PROTECTION Contents of Material Submittal 1 . Sprinkler Heads 2.Pipe and Fittings 3.Valves and Riser Components 4. Seismic and Hangers 5.Miscellaneous 2017 NW Vaughn St.#10087 Portland, OR 97296 Phone: 360-605-1133 Worldwide www.tyco-fire.com Vico® Contacts Series TY-FRB - 2.8, 4.2, 5.6, and 8.0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage IMPORTANT ceiling. This recessed pendent sprin- kler uses one of the following recessed :. Refer to Technical Data Sheet escutcheons: ii N TFP2300 for warnings pertaining to regulatory and health information. • Two-piece Style 10 (1/2 in. NPT) Always refer to Technical Data or Style 40 (3/4 in. NPT) Recessed j. i Y Escutcheon with 1/2 in. (12,7 mm)of Sheet TFP700 for the "INSTALLER recessed adjustment or up to 3/4 in. WARNING' that provides cautions (19,1 mm) of total adjustment from with respect to handling and instal- the flush pendent position. lation of sprinkler systems and corn- a ', w ponents. Improper handling and • Two-piece Style 20 (1/2 in. NPT) installation can permanently damage or Style 30 (3/4 in. NPT) Recessed a sprinkler system or its compo- Escutcheon with 1/4 in. (6,4 mm) of nents and cause the sprinkler to fail recessed adjustment or up to 1/2 in. to operate in a fire situation or cause (12,7 mm) of total adjustment from it to operate prematurely the flush pendent position. The adjustment provided by the Scan the OR code or enter the URL recessed escutcheon reduces the .p . riot in a web browser to access the most accuracy to which the fixed pipe drops up-to-date electronic version of this to the sprinklers must be cut. document. Data rates mayapply. Corrosion-resistant coatings, where '« , applicable, are utilized to extend the ■El ir ■ 1 life of copper alloy sprinklers beyond what would be obtained when exposed jj the standards of any authorities having ■ 1� to corrosive atmospheres. Although ■• corrosion-resistant coated sprinklers Jurisdiction.Failure to do so may impair •• ■ have passed the standard corrosion the performance of these devices. LI. �■ `. . tests of the applicable approval agen- The owner is responsible for maintain- cies, the is not resentative r ire rotection stem and ■ .. ■ ■ .. of all possible orrosi eratpmospheres. devices/inf properr operating condition. 1_ Consequently, it is recommended that The installing contractor or sprinkler .T the end user be consulted with respect manufacturer should be contacted with E to the suitability of these coatings for any questions. any given corrosive environment. The NFPA 13 prohibits installation of 1/2 in. effects of ambient temperature, con NPT sprinklers with K-factors greater docs.jci.com/tycofire/tfp171 centration of chemicals, and gas/ than 5.6 in new construction. They are chemical velocity, should be o- intended for retrofit in existing sprinkler the c ered,as a minimum,along with the or- General rosive nature of the chemical to which systems only. the sprinklers will be exposed. Sprinkler Description An intermediate level version of the The TYCO Series TY-FRB 2.8,4.2,5.6, Series TY FRB Pendent Sprinklers Identification and 8.0 K-factor Upright, Pendent, is detailed in technical data sheet and Recessed Pendent Sprinklers TFP356. Sprinkler guards are detailed Number (SIN) described in herein are quick response, in technical data sheet TFP780. standard coverage, decorative 3 mm TY1131 . . . Upright 2.8K, 1/2 in. NPT glass bulb-type spray sprinklers.They NOTICE TY1231 . . Pendent 2.8K, 1/2 in. NPT are designed for use in light or ordinary The Series TY-FRB 2.8, 4.2, 5.6, TY2131 . . . Upright 4.2K,1/2 in. NPT hazard,commercial occupancies such and 8.0 K-factor Upright, Pendent, TY2231 . . Pendent 4.2K,1/2 in. NPT as banks, hotels, and shopping malls. and Recessed Pendent Sprinklers TY3131 . . . Upright 5.6K, 1/2 in. NPT The sprinkler, where applicable, is described herein must be installed TY3231 .. Pendent 5.6K,1/2 in.NPT intended for use in areas with a finished and maintained in compliance with this document and with the applicable TY4131 . . . Upright 8.0K,3/4 in. NPT standards of the National Fire Protec- TY4231 . . Pendent 8.0K,3/4 in. NPT tion Association (NFPA), in addition to TY4831 . . . Upright 8.0K, 1/2 in. NPT TY4931 . . Pendent 8.0K, 1/2 in. NPT Page 1 of 12 DECEMBER 2022 TFP171 TFP171 Page 2 of 12 *Temperature rating ** Pipe thread connections per 1 - Frame 3 - Sealing 5 - Compression is indicated on ISO 7-1 can be provided on ESCUTCHEON 2 - Button Assembly Screw Deflector. special request. PLATE SEATING 4 - Bulb 6 - Deflector* SURFACE 7 - Bushing (11,17 .---------- I / ------ P __ __ __ 7/1 mm) �—' �. �\ _. 1 i■r= 1 , 4 MAKE N 21/4" ���� r 2 ill _-- (57,2 mm) I 4 jriii —� 2-3/16" AO (55,6 mm) 1-9/16" 1/2" NPT** t WRENCH STYLE 10 or 20 2-7/8"(73,0 mm)DIA. - FLATS RECESSED UPRIGHT PENDENT ESCUTCHEON RECESSED PENDENT CROSS SECTION FIGURE 1 QUICK RESPONSE SERIES TY-FRB UPRIGHT(TY1131)AND PENDENT(TY1231)SPRINKLERS 2.8 K-FACTOR, 1/2 IN. NPT *Temperature rating ** Pipe thread connections per 1 - Frame 3 - Sealing 5 - Compression is indicated on ISO 7-1 can be provided on ESCUTCHEON 2 - Button Assembly Screw Deflector. special request. PLATE SEATING 4 - Bulb 6 - Deflector* SURFACE 1 T 3 (11,1 mm) .-A 'A 2 NOMINAL 2-3/16" gm`MAKE-IN i (55,6 mm)�r 2-3/16" 101-1/2" 4101 I 4 j (55,6 mm) I (38,11mm) I _ �, ----. iar 6* 1/2" NPT** } WRENCH STYLE 10 or 20 2-7/8"(73,0 mm)DIA. - FLATS RECESSED UPRIGHT PENDENT ESCUTCHEON RECESSED PENDENT CROSS SECTION FIGURE 2 QUICK RESPONSE SERIES TY-FRB UPRIGHT(TY2131)AND PENDENT(TY2231)SPRINKLERS 4.2 K-FACTOR, 1/2 IN. NPT Technical Finishes Design Sprinkler:See Table D Data Recessed Escutcheon:Signal or Pure White, Criteria Grey Aluminum,Jet Black,Chrome Plated, Approvals or Natural Brass The TYCO Series TY-FRB 2.8,4.2,5.6, UL and C-UL Listed Physical Characteristics and 8.0 K-factor Upright, Pendent, FM, LPCB,and NYC Approved Frame Bronze and Recessed Pendent Sprinklers are EAC Approved Button Brass/Copper intended for fire protection systems Sealing Assembly..Beryllium Nickel w/TEFLON stan- Note:For complete approval information, Bulb Glass designed in accordance with the including corrosion-resistant status, see Compression Screw Bronze dard installation rules recognized by Tables A,B, C and D. Deflector Copper/Bronze the applicable Listing or Approval Maximum Working Pressure Bushing(K-2 8) Bronze agency, such as UL Listing based on See Table E the requirements of NFPA 13 and FM Operation Approval based on the requirements Discharge Coefficient of the FM Global Loss Prevention Data K=2.8 gpm/psi'i(40,3 Lpm/bars=) The glass bulb contains a fluid that Sheets. Use only the style 10, 20, 30, K=4.2 gpm/psi"(60,5 Lpm/bars) expands when exposed to heat.When or 40 recessed escutcheon,as applica- K=5.6 gpm/psii(80,6 Lpm/bars=) the rated temperature is reached, the ble,for recessed pendent installations. K=8.0 gpm/psi"(115,2 Lpm/bars=) fluid expands sufficiently to shatter the Temperature Rating glass bulb, allowing the sprinkler to See Tables A and B activate and water to flow. TFP171 Page 3 of 12 *Temperature rating ** Pipe thread connections per 1 - Frame 3 - Sealing 5 - Compression is indicated on ISO 7-1 can be provided on 2 - Button Assembly Screw Deflector., special request. ESCUTCHEON 4 - Bulb 6 - Deflector* PLATE SEATING SURFACE fir t --- rr_ 3 7/16" —'��1'— 1AJ (011 (11,1 mm) —NOMINAL —� } 2-3/16" �,44.101 �all42 MAKE-IN I (55,6 mm) _� (55 6/mm) I 1 4 1-1/2" (38,1 mm) C 5 6 1/2" NPT** f WRENCH 1 STYLE 10 or 20 2-7/8"(73,0 mm)DIA. - FLATS RECESSED UPRIGHT PENDENT ESCUTCHEON RECESSED PENDENT CROSS SECTION FIGURE 3 QUICK RESPONSE SERIES TY-FRB UPRIGHT(TY3131)AND PENDENT(TY3231)SPRINKLERS 5.6 K-FACTOR, 1/2 IN.NPT *Temperature rating ** Pipe thread connections per 1 - Frame 3 - Sealing 5 - Compression is indicated on ISO 7-1 can be provided on ESCUTCHEON 2 - Button Assembly Screw Deflector. special request. PLATE SEATING 4 - Bulb 6 - Deflector* SURFACE Air PA a 1/2" F. 3 (12,7 mm) NOMINAL I I II / Tr_m_____________ A MAKE-IN (2 5/,7 —` �r 4 2 •—� 2-1/4" mm) 4 _ 52-1 4" jir 1-9/16" I ( ) . (39,7 mm) 410. `��5 R e. 3/4" NPT** f WRENCH STYLE 30 or 40 FLATS RECESSED 2-7/8"(73,0 mm)DIA. UPRIGHT PENDENT ESCUTCHEON RECESSED PENDENT CROSS SECTION FIGURE 4 QUICK RESPONSE SERIES TY-FRB UPRIGHT(TY4131)AND PENDENT(TY4231)SPRINKLERS 8.0 K-FACTOR,3/4 IN. NPT CEILING PLATE 1 - Frame 5 - Compression SEATING SURFACE 2 - Button Screw 1 3 - Sealing 6 - Deflector * it i-, �--'�- � I 4 V Assembly L y 3 4 Bulb 7/16" 2-1/4 y� (11,1 mm) __ III , (57,2 mm) ;A 2 NOMINAL } — MAKE-IN 1 * Temperature rating is r I 2 3/16" 01 9/16" 4 indicated on Deflector. '1 (556 mm) (39,7 mm) . '7�5 ** Pipe thread connections _--_---__-_•• �� i,,` per ISO 7-1 can be i 6 * provided on special 1/2" NPT** f WRENCH request. FLATS UPRIGHT PENDENT CROSS SECTION FIGURE 5 QUICK RESPONSE SERIES TY-FRB UPRIGHT(TY4831)AND PENDENT(TY4931)SPRINKLERS 8.0 K-FACTOR, 1/2 IN. NPT TFP171 Page 4 of 12 Installation Series TY-FRB Recessed Pendent corrosive products of combustion, but Sprinklers have not operated,should be replaced The TYCO Series TY-FRB 2.8,4.2,5.6, The Series TY-FRB Recessed Pendent if they cannot be completely cleaned and 8.0 K-factor Upright, Pendent,and Sprinklers must be installed in accor- by wiping the sprinkler with a cloth or Recessed Pendent Sprinklers must dance with the following instructions: by brushing it with a soft bristle brush. be installed in accordance with this Step 1.After installing the Style 10,20, Care must be taken to avoid damage section. 30, or 40 Mounting Plate, as applica- to the sprinklers before, during, and General Instructions ble,over the sprinkler threads and with after installation. Sprinklers damaged Do not install any bulb type sprinkler pipe-thread sealant applied to the pipe by dropping, striking, wrench twist/ if the bulb is cracked or there is a loss threads,hand-tighten the sprinkler into slippage,or the like,must be replaced. of liquid from the bulb.With the sprin- the sprinkler fitting. Also, replace any sprinkler that has kler held horizontally,a small air bubble Step 2. Tighten the sprinkler into the a cracked bulb or that has lost liquid should be present.The diameter of the sprinkler fitting using only the W-Type 7 fnst its bulb. For more information,see air bubble is approximately 1/16 in. Installation section. Pp Y Recessed Sprinkler Wrench as shown (1,6 mm) for the 135°F (57°C) and in Figure 15.Apply the sprinkler wrench The owner is responsible for the 3/32 in. (2,4 mm)for the 286°F (141°C) to the sprinkler wrench flats as shown inspection,testing,and maintenance of temperature ratings. A leak-tight in Figure 1 to 4. their fire protection system and devices 1/2 in. NPT sprinkler joint should in compliance with this document, as Step 3. After the ceiling is installed be obtained by applying a mini- or the finish coat is applied, slide on well as with the applicable standards mum-to-maximum torque of 7 ft-lb the Style 10,20, 30,or 40 closure over of the National Fire Protection Associ- to 14 ft-lb (9,5 N•m to 19,0 N m). A the Series TY-FRB Recessed Pendent ation such as NFPA 25, in addition to leak tight 3/4 in. NPT sprinkler joint Sprinkler and push the closure over the the standards of any other authorities should be obtained with a torque of mounting plate until its flange comes in having jurisdiction.Contact the install- 10 ft-lb to 20 ft-lb (13,4 N•m to co anti w the ceiling. g ing contractor or sprinkler manufac- 26,8 N•m). Higher levels of torque canturer regarding any questions. distort the sprinkler inlet and cause leakage or impairment of the sprin- Care and Automatic sprinkler systems are rec- kler.Do not attempt to compensate for ommended to be inspected, tested, insufficient adjustment in the escutch- Maintenance and maintained by a qualified Inspec- eon plate by under or over-tightening tion Service in accordance with local the sprinkler. Re-adjust the position of The TYCO Series TY-FRB 2.8,4.2,5.6, requirements and/or national codes. the sprinkler fitting to suit. and 8.0 K-factor Upright, Pendent,and Care must be exercised to avoid Recessed Pendent Sprinklers must be damage to the sprinklers before, Series TY-FRB Upright and Pendent maintained and serviced in accordance during, and after installation. Sprin- Sprinklers with this section. Before closing a fire klers damaged by dropping, striking, The Series TY-FRB Upright and protection system main control valve wrench twist/slippage,or the like,must Pendent Sprinklers must be installed for maintenance work on the fire pro- be replaced.Also,replace any sprinkler in accordance with the following tection system that it controls, obtain that has a cracked bulb or that has lost instructions: permission to shut down the affected liquid from its bulb. For more informa- Step 1.Install pendent sprinklers in the fire protection systems from the proper tion,see Installation section. pendent position. Install upright sprin- authorities and notify all personnel who klers in the upright position. may be affected by this action. Initial and frequent visual inspections of random samples are recommended for Step 2. With pipe thread sealant Absence of the outer piece of an corrosion-resistant sprinklers to verify applied to the pipe threads, hand- escutcheon, which is used to cover the integrity of the corrosion-resistant tighten the sprinkler into the sprinkler a clearance hole, can delay sprinkler material of construction. Thereafter, fitting. operation in a fire situation. annual inspections according to NFPA Step 3. Tighten the sprinkler into the Sprinklers which are found to be 25 should suffice. Inspections of cor- sprinkler fitting using only the W-Type leaking or exhibiting visible signs of rosion-resistant sprinklers are recom- 6 Sprinkler Wrench as shown in corrosion must be replaced. mended at close range,instead of from Figure 14. Apply the sprinkler wrench the floor level per NFPA. Inspection at 9 pP Y P Automatic sprinklers must never be close range can better determine the to the sprinkler wrench flats as shown painted, plated, coated, or other- exact sprinkler condition and the long- in Figure 1 to Figure 5. wise altered after leaving the factory. term integrity of the corrosion-resistant Modified sprinklers must be replaced. material,which can be affected by the Sprinklers that have been exposed to corrosive conditions present. TFP171 Page 5 of 12 2-7/8" DIA. _ 2-7/8" DIA. 5/8±1/4" (73,0 mm) 3/4"(19,1 mm) 1/2±1/8 (73,0 mm) 1/2"(12,7 mm) (15,9±6,4 mm) 1/4"(6,4 mm) (12,7±3,2 mm) 2-1/4" DIA. 2-1/4" DIA. 1/4"(6,4 mm) / FACE OF (57,2 mm) 1 MOUNTING / FACE OF (57,2 mm) �1 SPRINKLER I PLATE SPRINKLER MOUNTING PLATE FITTING FITTING / 1/8" / 1/8" (3,2 mm) (3,2 mm) 411-- ��1_�I CAI__II v72 i I Z.j / "` \� . �i1 t MOUNTING 411 MOUNTING �: SURFACE SURFACE iitti- � Ar INN , CLOSURE SERIES 1-5/16"(33,3 mm) CLOSURE SERIES 1-5/16"(33,3 mm) TY-FRB 13/16"(20,6 mm) TY-FRB 1-1/16"(27,0 mm) FIGURE 6 FIGURE 7 SERIES TY-FRB RECESSED PENDENT SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON STYLE 20 RECESSED ESCUTCHEON 2.8 K-FACTOR, 1/2 IN. NPT 2.8 K-FACTOR, 1/2 IN.NPT 2-7/8" DIA. 2-7/8" DIA. 5/8±1/4" (73,0 mm) 3/4"(19,1 mm) 1/2±1/8" (73,0 mm) 1/2"(12,7 mm) (15,9±6,4 mm) (6,4 1/4 1/4"(6,4 mm) (12,7±3,2 mm) " 2-1/4" DIA. 2-1/4" DIA. mm) / FACE OF (57,2 mm) MOUNTING / FACE OF (57,2 mm) -y MOUNTING SPRINKLER PLATE SPRINKLER PLATE FITTING FITTING 8" (3,2 mm) (3,2 mm) 11 li ' -s \ F� �T T t ? i ,,, MOUNTING ,�' f MOUNTING SURFACE SURFACE __ = ' CLOSURE SERIES 1-1/4"(31,8 mm) CLOSURE SERIES 1-1/4"(31,8 mm) TY-FRB 3/4"(19,1 mm) TY-FRB 1"(25,4 mm) FIGURE 8 FIGURE 9 SERIES TY-FRB RECESSED PENDENT SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON STYLE 20 RECESSED ESCUTCHEON 4.2 K-FACTOR, 1/2 IN.NPT 4.2 K-FACTOR, 1/2 IN. NPT TFP171 Page 6 of 12 2-7/8" DIA. _ 2-7/8" DIA. 5/8±1/4" (73,0 mm) 3/4"(19,1 mm) 1/2±1/8" (73,0 mm) 1/2"(12,7 mm) (15,9±6,4 mm) (6,4 1/4 1/4"(6,4 mm) (12,7±3,2 mm) " 2-1/4" DIA. 2-1/4"DIA. mm) / FACE OF (57,2 mm) MOUNTING / FACE OF (57,2 mm) 1 MOUNTING SPRINKLER PLATE SPRINKLER PLATE FITTING FITTING / 1/8" / 1/8" (3,2 mm) (3,21mm) ' �l Ii _ l F7JT 1, , MOUNTING /'iii, f MSOUNTING URFACE �_„_ t SURFACE• -A ' CLOSURE SERIES 1-1/4"(31,8 mm) CLOSURE SERIES 1-1/4"(31,8 mm) TY-FRB 3/4"(19,1 mm) TY-FRB 1"(25,4 mm) FIGURE 10 FIGURE 11 SERIES TY-FRB RECESSED PENDENT SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON STYLE 20 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 IN. NPT 5.6 K-FACTOR, 1/2 IN. NPT 2-7/8" DIA. _ 2-7/8" DIA. 5/8±1/4" (73,0 mm) 3/4"(19,1 mm) 1/2±1/8" (73,0 mm) 1/2"(12,7 mm) (15,9±6,4 mm) 2-1/4" DIA. 1/4"(6,4 mm) (12,7±3,2 mm) 2-1/4" DIA. 1/4"(6,4 mm) / FACE OF (57,2 mm) 1 MOUNTING / FACE OF (57,2 mm) MOUNTING SPRINKLER I PLATE SPRINKLER PLATE FITTING FITTING 1/8" 1/8" / (3,2 mm) / (3,2 mm) • , 2,: t mro iw ill_ I W_ \ fir MOUNTING1Ii f MOUNTING f SURFACE SURFACE � 1 CLOSURE SERIES 1-5/16"(33,3 mm) CLOSURE SERIES 1-5/16"(33,3 mm) TY-FRB 13/16"(20,6 mm) TY-FRB 1-1/16"(27,0 mm) FIGURE 12 FIGURE 13 SERIES TY-FRB RECESSED PENDENT SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON STYLE 30 RECESSED ESCUTCHEON 8.0 K-FACTOR,3/4 IN. NPT 8.0 K-FACTOR,3/4 IN. NPT WRENCH G RECESS WRENCH RECESS i (END"A" USED FOR 1/2"NPT MODELS) �� %fir WRENCH RECESS PUSH WRENCH (END"B" USED FOR IN TO ENSURE 3/4" NPT MODELS) ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 14 FIGURE 15 W-TYPE 6 SPRINKLER W-TYPE 7 RECESSED WRENCH SPRINKLER WRENCH TFP171 Page 7 of 12 Sprinkler Finish5 Bulb Liquid K-Factor Type Temperature Color Natural Chrome Plated Polyester° Brass 135°F(57°C) Orange 155°F(68°C) Red Pendent 175°F(79°C) Yellow (TY1231) 200°F(93°C) Green 286°F(141°C) Blue 1,2,3,4 135°F(57°C) Orange 155°F(68°C) Red Upright 175°F(79°C) Yellow (TY1131) 2.8 200°F(93°C) Green 1/2 in.NPT 286°F(141°C) Blue 135°F(57°C) Orange Recessed Pendent 155°F(68°C) Red (TY1231)a 175°F(79°C) Yellow Figure 6 200°F(93°C) Green 1,2,4 135°F(57°C) Orange Recessed Pendent 155°F(68°C) Red (TY1231)b 175°F(79°C) Yellow Figure 7 200°F(93°C) Green NOTES a. Installed with Style 10(1/2 in.NPT)or Style 40(3/4 in.NPT)3/4 in.Total Adjustment Recessed Escutcheon,as applicable. b. Installed with Style 20(1/2 in.NPT)or Style 30(3/4 in.NPT)1/2 in.Total Adjustment Recessed Escutcheon,as applicable. c. Frame and Deflector only. 1. Listed by Underwriters Laboratories,Inc.,(UL)as Quick Response Sprinklers. 2. Listed by Underwriters Laboratories,Inc.,for use in Canada(C-UL)as Quick Response Sprinklers. 3. Approved by Factory Mutual Research Corporation(FM)as Quick Response Sprinklers. 4. Approved by the City of New York under MEA 354-01-E. 5. Where Polyester Coated Sprinklers are noted to be UL and C-UL Listed,the sprinklers are UL and C-UL Listed,the sprinklers are UL and C-UL Listed as corrosion-resistant sprinklers. TABLE A LABORATORY LISTINGS AND APPROVALS FOR 2.8 K-FACTOR SPRINKLERS TFP171 Page 8 of 12 Sprinkler Finish3 Bulb Liquid K-Factor Type Temperature Color Natural Chrome Plated Polyesters Brass 135°F(57°C) Orange 155°F(68°C) Red Pendent 175°F(79°C) Yellow (TY2231) 200°F(93°C) Green 286°F(141°C) Blue 135°F(57°C) Orange 155°F(68°C) Red Upright 175°F(79°C) Yellow (TY2131) 4.2 200°F(93°C) Green 1/2 in.NPT 1,2 286°F(141°C) Blue 135°F(57°C) Orange Recessed Pendent 155°F(68°C) Red (TY2231)a 175°F(79°C) Yellow Figure 8 200°F(93°C) Green 135°F(57°C) Orange Recessed Pendent 155°F(68°C) Red (TY2231)b 175°F(79°C) Yellow Figure 9 200°F(93°C) Green NOTES a. Installed with Style 10(1/2 in.NPT)or Style 40(3/4 in.NPT)3/4 in.Total Adjustment Recessed Escutcheon,as applicable. b. Installed with Style 20(1/2 in.NPT)or Style 30(3/4 in.NPT)1/2 in.Total Adjustment Recessed Escutcheon,as applicable. c. Frame and Deflector only. 1. Listed by Underwriters Laboratories,Inc.,(UL)as Quick Response Sprinklers. 2. Listed by Underwriters Laboratories,Inc.,for use in Canada(C-UL)as Quick Response Sprinklers. 3. Where Polyester Coated Sprinklers are noted to be UL and C-UL Listed,the sprinklers are UL and C-UL Listed,the sprinklers are UL and C-UL Listed as corrosion-resistant sprinklers. TABLE B LABORATORY LISTINGS AND APPROVALS FOR 4.2 K-FACTOR SPRINKLERS TFP171 Page 9 of 12 Sprinkler Finish8 K-Factor Type Temperature Bulb Liquid Color Lead Natural Brass Chrome Plated Polyesters Coated 135°F(57°C) Orange 155°F(68°C) Red Pendent 175°F(79°C) Yellow 1,2,3,4,5,6,7 1,2,3,5,7 (TY3231) 200°F(93°C) _ Green 286°F(141°C) Blue 135°F(57°C) Orange 155°F(68°C) Red Upright 175°F(79°C) Yellow 1,2,3,5,6,7 1,2,3,5,7 (TY3131) 200°F(93°C) Green 5.6 286°F(141°C) Blue 1/2 in. NPT 135°F(57°C) _ Orange Recessed 155°F(68°C) Red Pendent 175°F(79°C) Yellow 1,2,4,5,7 N/Ad (TY3231)a Figure 10 200°F(93°C) Green 286°F(141°C) _ Blue 135°F(57°C) Orange Recessed 155°F(68°C) Red Pendent 175°F(79°C) Yellow 1,2,3,4,5,7 N/A (TY3231)b Figure 11 200°F(93°C) Green 286°F(141°C) Blue NOTES a. Installed with Style 10(1/2 in.NPT)or Style 40(3/4 in.NPT)3/4 in.Total Adjustment Recessed Escutcheon,as applicable. b. Installed with Style 20(1/2 in.NPT)or Style 30(3/4 in.NPT)1/2 in.Total Adjustment Recessed Escutcheon,as applicable. c. Frame and Deflector only. d. Not available(N/A). 1. Listed by Underwriters Laboratories,Inc.,(UL)as Quick Response Sprinklers. 2. Listed by Underwriters Laboratories,Inc.,for use in Canada(C-UL)as Quick Response Sprinklers. 3. Approved by Factory Mutual Research Corporation(FM)as Quick Response Sprinklers. 4. Approved by the Loss Prevention Certification Board(LPCB Ref.No.007k/04)as Quick Response Sprinklers.Note the following exceptions: •LPCB does not rate the thermal sensitivity of recessed sprinklers. •The recessed pendent(TY3231)sprinklers with a 286°F(141°C)temperature rating are not LPCB Approved. 5. Approved by the City of New York under MEA 354-01-E. 6. VdS Approved(For details,contact Johnson Controls,Enschede,Netherlands,Tel.31-53-428-4444/Fax 31-53-428-3377.) 7. EAC Approved. 8. Where Polyester Coated and Lead-Coated Sprinklers are noted to be UL and C-UL Listed,the sprinklers are UL and C-UL Listed as Corrosion-Resistant Sprinklers.Where Lead-Coated Sprinklers are noted to be FM Approved,the sprinklers are FM Approved as a Corrosion-Resistant Sprinklers. TABLE C LABORATORY LISTINGS AND APPROVALS FOR 5.6 K-FACTOR SPRINKLERS TFP171 Page 10 of 12 Sprinkler Finish9 K-Factor Type Temperature Bulb Liquid Lead Color Natural Brass Chrome Plated Polyesters Coated 135°F(57°C) Orange 155°F(68°C) Red Pendent 175°F(79°C) Yellow (TY4231) 200°F(93°C) Green 286°F(141°C) Blue 1,2,3,4,5,6,7,8 1,2,5,8 135°F(57°C) Orange 155°F(68°C) Red Upright 175°F(79°C) Yellow (TY4131) 200°F(93°C) Green 8.0 286°F(141°C) Blue 3/4 in. NPT 135°F(57°C) Orange Recessed 155°F(68°C) Red Pendent 175°F(79°C) Yellow 1,2,5,8 N/Ad (TY4231)a Figure 12 200°F(93°C) Green 286°F(141°C) Blue 135°F(57°C) Orange Recessed 155°F(68°C) Red Pendent 175°F 79°C Yellow 1,2,3,5,8 N/A (TY4231)b ( ) Figure 13 200°F(93°C) Green 286°F(141°C) Blue 135°F(57°C) Orange 155°F(68°C) Red Pendent 175°F(79°C) Yellow (TY4931) 200°F(93°C) Green 8.0 286°F(141°C) Blue 1/2 in. 1,2,4,5,6,8 1,2,5,8 NPT 135°F(57°C) Orange 155°F(68°C) Red Upright 175°F(79°C) Yellow (TY4831) 200°F(93°C) Green 286°F(141°C) Blue NOTES a. Installed with Style 10(1/2 in.NPT)or Style 40(3/4 in.NPT)3/4 in.Total Adjustment Recessed Escutcheon,as applicable. b. Installed with Style 20(1/2 in.NPT)or Style 30(3/4 in.NPT)1/2 in.Total Adjustment Recessed Escutcheon,as applicable. c. Frame and Deflector only. d. Not available(N/A). 1. Listed by Underwriters Laboratories,Inc.,(UL)as Quick Response Sprinklers. 2. Listed by Underwriters Laboratories,Inc.,for use in Canada(C-UL)as Quick Response Sprinklers. 3. Approved by Factory Mutual Research Corporation(FM)as Quick Response Sprinklers. 4. Approved by the Loss Prevention Certification Board(LPCB Ref.No.007k/04)as Quick Response Sprinklers.However,LPCB does not rate the thermal sensitivity of recessed sprinklers. 5. Approved by the City of New York under MEA 354-01-E. 6. VdS Approved(For details,contact Johnson Controls,Enschede,Netherlands,Tel.31-53-428-4444/Fax 31-53-428-3377.) 7. Approved by the Loss Prevention Certification Board(LPCB Ref.No.094a/06)as Quick Response Sprinklers. 8. EAC Approved. 9. Where Polyester Coated and Lead-Coated Sprinklers are noted to be UL and C-UL Listed,the sprinklers are UL and C-UL Listed as Corrosion-Resistant Sprinklers.Where Lead-Coated Sprinklers are noted to be FM Approved,the sprinklers are FM Approved as a Corrosion-Resistant Sprinklers. TABLE D LABORATORY LISTINGS AND APPROVALS FOR 8.0 K-FACTOR SPRINKLERS TFP171 Page 11 of 12 Sprinkler Finish K-Factor Type Natural Chrome Brass Plated Polyester Lead Coated Pendent(TY1231) and 2.8 Upright(TY1131) 1/2 in. 175 psi(12,1 bar) N/A2 NPT Recessed Pendent(TY1231) Pendent(TY2231) and 4.2 Upright(TY2131) 1/2 in. 175 psi(12,1 bar) N/A NPT Recessed Pendent(TY2231) Pendent(TY3231) and 5.6 Upright(TY3131) 1/2 in. 250 psi(17,2 bar) NPT or 175 psi(12,1 bar)1 Recessed Pendent(TY3231) Pendent(TY4231) 175 psi and (12,1 bar) 8.0 Upright(TY4131) 3/4 in. 175 psi(12,1 bar) NPT Recessed N/A Pendent(TY4231) 8.0 Pendent(TY4931) 175 psi 1/2 in. and 175 psi(12,1 bar) NPT Upright(TY4831) (12,1 bar) NOTES 1. The maximum working pressure of 250 psi(17,2 bar)only applies to the Listing by Underwriters Laboratories Inc.(UL);the Listing by Underwriters Laboratories,Inc.for use in Canada(C-UL);and,the Approval by the City of New York. 2. Not available(N/A). TABLE E MAXIMUM WORKING PRESSURE TFP171 Page 12 of 12 P/N 57 - XXX - X - XXX i SIN SPRINKLER TEMPERATURE FINISH RATINGS 330 2.8K UPRIGHT(1/2 in. NPT) TY1131 1 NATURAL BRASS 135 135°F(57°C) 331 2.8K PENDENT(1/2 in.NPT) TY1231 3 PUREWHITE POLYESTER(RAL9010)1 155 155°F(68°C) 340 4.2K UPRIGHT(1/2 in.NPT) TY2131 4 SIGNAL WHITE 175 175°F(79°C) POLYESTER(RAL9003) 341 4.2K PENDENT(1/2 in.NPT) TY2231 5 JET BLACK 2 200 200°F(93°C) POLYESTER(RAL9005)2 5.6K UPRIGHT(1/2 in.NPT) TY3131 7 LEAD COATED 286 286°F(141°C) 371 5.6K PENDENT(1/2 in.NPT) TY3231 9 CHROME PLATED 390 8.0K UPRIGHT(3/4 in.NPT) TY4131 NOTES 1. Eastern Hemisphere sales only. 2. Available in only 2.8K,4.2K,and 8.0K,155°F(68°C)and 200°F(93°C);requires longer 391 8.0K PENDENT(3/4 in.NPT) TY4231 lead time to manufacture. 360 8.0K UPRIGHT(1/2 in.NPT) TY4831 361 8.0K PENDENT(1/2 in.NPT) TY4931 TABLE F SERIES TY-FRB PENDENT AND UPRIGHT SPRINKLERS PART NUMBER SELECTION Limited Ordering Recessed Escutcheon Specify: Style (10, 20, 30, or 40) WarrantyProcedure Recessed Escutcheon with (specify") finish, P/N(specify') For warranty terms and conditions,visit Contact your local distributor for *Refer to technical data sheet TFP77O www.tyco-fire.com. availability. When placing an order, Sprinkler Wrench indicate the full product name and Part Specify: W-Type 6 Sprinkler Wrench, Number(P/N). P/N 56-000-6-387 Sprinkler Assemblies with NPT Specify: W-Type 7 Sprinkler Wrench, Thread Connections P/N 56-850-4-001 Specify: Series TY-FRB (Specify SIN), (specify K-factor), (specify Pendent or Upright)Sprinkler(specify)temperature rating, (specify) finish or coating, P/N (specify from Table F) 1467 Elmwood Avenue,Cranston,RI 02910 I Telephone+1-401-781-8220 �J®2022 Johnson Controls.All rights reserved.All specifications and other information shown were current as of document revision date and are subject to change without notice. Johnson A l 1 NATIONAL FIRE PROTECTION ASSOCIATION and NFPA are registered trademarks of National Fire Protection Association. Controls TEFLON is a trademark of The Chemours Company FC,LLC Worldwide www.tyco-fire.com tIICD o Contacts TFP171 Change History Appendix ISSUE DATE NOTES Page 9, Table C, added note to footnote 4, removing LPCB Approved from Pendent and Recessed 12 22 Pendent TY3231 286°F (141°C) temperature rating; Page 9, Table C, removed note Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/06)as Quick Response Sprinklers, formerly footnote 7. Page 1, added QR code and URL to allow convenient access to electronic version from printed doc- ument; Page 2, Approvals sub-section, Page 9, Table C, Page 10, Table D, TY3231, TY4131, TY4231, 09-22 TY3131 sprinkler only, added EAC Approved; Page 12, changed corporate address and telephone number to 1467 Elmwood Avenue, Cranston, RI 02910 I Telephone +1-401-781-8220, formerly 1400 Pennbrook Parkway, Lansdale, PA 19446 I Telephone+1-215-362-0700. 12 20 Changed temperature rating of TY4131 8.0K Upright Sprinkler with Blue bulb liquid color to 286°F(141°C), formerly shown incorrectly as 200°F(93°C). 03-20 Removed LPCB Approval from TY3131 5.6K Upright Sprinkler. Updated Tyco®branding and document format;Added Johnson Controls copyright;Added disclaimer stating specifications and information subject to change without notice; Added reference to Regula- 07 18 tory and Health Warning Technical Data Sheet TFP2300;Added Poly-Stainless Grey Aluminum finish, formerly described in Technical Data Sheet TFP682. 09-17 Added statement prohibiting sprinklers featuring K-factors greater than 5.6 and 1/2 in. NPT thread size from installation in new construction, explicitly for retrofit applications only. 11-15 Clarified finishes and polyester coating. 10-13 Removed Eastern Hemisphere Sales Only limitation from TY4831 and TY4931 upright and pendent 8.0K x 1/2 in. NPT sprinklers;Added torque requirements for 3/4 in. NPT sprinklers. 03-13 Updated and standardized RAL color finishes. Added higher temperature rating for TY3231 and TY4241; Clarified LPCB certification; Corrected SIN 07-10 numbers in Table C for 2.8K and 4.2K sprinklers;Simplified footnotes in Tables A and B;Clarified Instal- lation and Care and Maintenance sections. 08-07 Added FM Approval for 5.6K White Coated Sprinkler with Style 20 Recessed Escutcheon application. 03-07 Added 8.0K 1/2 in. NPT Pendent and Upright Sprinklers. 04 06 Added statement indicating TY3131 and TY3231 are UL and C-UL Listed for 250 psi(17,2 bar)maximum working pressure. 07 04 Added reference to Installer Warning data sheet TFP700; Added LPCB Reference Numbers; Added option for White RAL9010 for Eastern Hemisphere sales. 04-03 Added 4.2K sprinkler;Added recessed option for 2.8K pendent sprinkler. 01-03 Added new Tyco Fire&Building Products masthead. 09 02 New Technical Data Sheet TFP171 describes Series TY-FRB Upright, Pendent,and Recessed Pendent Sprinklers. /J 1467 Elmwood Avenue,Cranston,RI029101 Telephone+1-401-781-8220 Johnson //J ®2022 Johnson Controls.All rights reserved.All specifications and other information shown were current as of document revision date and are subject to change without notice. Controls Victaulic® VicFlexTM Sprinkler Fittings ictaulic' Series AH2 and AH2-CC Braided Flexible Hoses 10.85 FlexM • Series AH2 Series AH2-CC 1.0 PRODUCT DESCRIPTION Available Sizes by Component Series AH2 1"/DN25 ID Braided Hose: 31, 36, 48, 60, 72"/790, 915, 1220, 1525, 1830 mm. Note: length includes adapter nipple and 5.75"/140 mm straight reducer. Series AH2-CC 1"/DN25 ID Braided Hose: 31, 36, 48, 60, 72"/790, 915, 1220, 1525, 1830 mm. Note: length includes captured coupling and 5.75"/140 mm straight reducer. Connections • From Branchline • 3/4"/20mm BSPT female thread (VdS only) • 11/4"/32mm BSPT female thread (LPCB only) • 1"/25mm NPT or BSPT female Thread • 1"/25mm Grooved IGS (refer to Submittal 10.54 for additional IGS connections) • No. 116 CPVC Adapter (1"/25mm Female CPVC Socket x 1"/25mm Grooved IGS) • No. 142 Welded Outlet • Style 922 Outlet-T • Style 920N Mechanical-T Outlet • No. 65 Grooved End of Run Fitting • Hose Inlet • 1"/25mm Grooved IGS • 1"/25mm NPT or BSPT male thread • 3/4"/20mm BSPT male thread (VdS only) • 11/4"/32mm BSPT male thread (LPCB only) ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION,MAINTENANCE OR SUPPORT. victaulic.com if victaulic.com 1.0 PRODUCT DESCRIPTION (CONTINUED) • Sprinkler Reducer • Sprinkler Connection: l/" and 3/4"/15mm and 20mm NPT or BSPT female thread • Straight Lengths: 5.75" 9" 13"/140mm, 230mm, 330mm • 90° Elbows • Standard Short • Low Profile Short • Standard Long • Low Profile Long (Short elbows typically used with concealed sprinklers. Long elbows typically used with recessed pendent sprinklers) Brackets • Style AB2 for suspended and hard-lid ceilings and sidewalls, allows for vertical sprinkler adjustment, and installation before most ceiling tiles in place • Style AB3 for surface mount applications, wood, metal and block walls, or ceilings • Style AB4 for hard-lid ceilings with hat furring channel grid systems, allows for vertical sprinkler adjustment • Style AB5 for hard-lid ceilings and sidewalls, allows for vertical sprinkler adjustment • Style AB7 for suspended and hard-lid ceilings • Style AB7 Adjustable for suspended and hard-lid ceilings • Style AB10 for Armstrong® TechZone°" ceilings • Style AB11 for lay-in panel suspended t-grid ceilings or drywall suspended t-grid ceilings, allows for low profile installations (use only with 90° low profile elbows) • Style AB12 for suspended and hard-lid ceilings, allows for vertical sprinkler adjustment, and allows for low profile installation down to 4°/100mm. • Style ABBA bracket for suspended, exposed, and hard-lid ceilings • Style ABMM bracket for surface mount and stand off-mount applications, wood, metal and block walls, or ceilings and hard-lid ceilings • Strut channel and pipe clamp, not supplied by Victaulic Maximum Working Temperature • 225°F/107°C • 150°F/65°C (No. 116 CPVC Adapter) Maximum Working Pressure • 200 psi/1375 kPa (FM Approval) • 175 psi/1206 kPa (cULus Listed) • 1600 kPa/232 psi (VdS/LPCB Approved) • 1.4 MPa (CCCf Approved) • 175 psi/1206 kPa (No. 116 CPVC Adapter) Minimum Bend Radius • 7"/178 mm (FM/CCCf Approval) • 2"/51 mm (cULus Listed) • 3"/76.2 mm (VdS/LPCB Approved) • • 10.85 5839 Rev AL Updated 02/2022 ©2022 Victaulic Company.All rights reserved. victaulic.com 1.0 PRODUCT DESCRIPTION (CONTINUED) ' Maximum Allowable Sprinkler K-Factors • FM (l '/15 mm reducer) K5.6/8,1 (S.I.), (3/4720 mm reducer) K14.0/20,2 (S.I.) • cULus (1/2"/15 mm reducer) K8.0/11,5 (S.I.), (3/4720 mm reducer) K14.0/20,2 (S.I.) • VdS/LPCB (1/2"/15 mm reducer) K5.6/8,1 (S.I.), (3/4"/20 mm reducer) K8.0/11,5 (S.I.) 2.0 CERTIFICATION/LISTINGS ® cOus VdS 'LPCB: ® • CE LISTED 2809 NOTE • The VicFlexSeries AH2 Hose has been tested and evaluated by Spears®for acceptable use with Spears®CPVC Products and is therefore covered under the Spears®FlameGuard®Installer Protection Plan. 3.0 SPECIFICATIONS — MATERIAL Series AH2: Flexible Hose: 300-series Stainless Steel Collar/Weld Fitting: 300-series Stainless Steel Gasket Seal: Victaulic EPDM Isolation Ring: Nylon Nut and Nipple: Carbon Steel, Zinc-Plated Reducer (' "/15 mm or 34720 mm): Carbon Steel, Zinc-Plated Low Profile Elbows: Ductile Iron, Zinc-Plated Brackets: Carbon Steel, Zinc-Plated Series AH2-CC: Flexible Hose: 300-series Stainless Steel Collar/Weld Fitting: 300-series Stainless Steel Gasket Seal: Victaulic EPDM Isolation Ring: Nylon Coupling Retainer Ring: Polyethelene Nut: Carbon Steel, Zinc-Plated Reducer (' "/15 mm or 3/"/20 mm): Carbon Steel, Zinc-Plated Low Profile Elbows: Ductile Iron, Zinc-Plated Housing: Ductile iron conforming to ASTM A 536, Grade 65-45-12. Ductile iron conforming to ASTM A 395, Grade 65-45-15, is available upon special request. Coupling Housing Coating: • Orange enamel (North America, Asia Pacific). • Red enamel (Europe). • Hot dipped galvanized. Gasket:' Grade "E" EPDM (Type A) FireLock EZ products have been Listed by Underwriters Laboratories Inc., Underwriters Laboratories of Canada Limited, and Approved by Factory Mutual Research for wet and dry (oil free air) sprinkler services within the rated working pressure. Services listed are General Service Guidelines only.It should be noted that there are services for which these gaskets are not compatible. Reference should always be made to the latest Victau!ic Gasket Selection Guide for specific gasket service guidelines and for a listing of services which are not compatible. Bolts/Nut: Zinc electroplated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A 449 and physical requirements of ASTM A 183. Linkage: CrMo Alloy Steel zinc electroplated per ASTM B633 Zn/Fe 5, Type III Finish No. 116 Adapter Fitting: CPVC and Brass Seal: Victaulic EPDM 10.85 5839 Rev AL Updated 02/2022 ©2022 Victaulic Company.All rights reserved. victaulic.com • 4.0 DIMENSIONS Product Details - Series AH2 Braided Hose Item Description �— 1' Flexible Hose Q 6Q 0 O 00 O 2 __ Isolation Ring I I 3 Gasket =11114 wmiiiilI 4 Nut 5 Adapter Nipple A _ 6 _ Braid a "II 7 Collar/VVeld Fitting 8 Sleeve 9 Reducer Hose Length Dimensions Hose Length A B inches inches inches mm mm mm 31 25.3 31 790 641 790 36 31.3 36 915 794 915 48 42.3 48 1219 1073 1220 60 54.3 60 1525 1378 1525 72 66.3 72 1830 1683 1830 Series AH2-CC Braided Hose Item _ Description 1 Flexible Hose © ? Isolation Ring _ O O 0 0 O O 0 O 3 Gasket 4 _ Nut 071111 •;ruw uu mliii• 5 Captured Coupling _ iiiiii',iii� 6 _ Braid 7 Collar/Weld Fitting A 8 Sleeve B > 9 Reducer Hose Length A B inches inches inches mm mm mm 31 24.5 29.8 790 622 757 36 29.5 34.8 915 749 884 48 41.5 46.8 1219 1054 1189 60 53.5 58.8 1525 1359 1494 72 > 65.5 70.8 1830 1664 1798 10.85 5839 Rev AL Updated 02/2022 ©2022 Victaulic Company.All rights reserved. victaulic.com • • 4.0 DIMENSIONS (CONTINUED) Standard Reducer IIIIIIIIIIIIIIIIIIIIIIIII!IIIIIII I ulllnnmiln���'�iIIiid 5.75"/140 mm straight reducer Optional Reducers 2.62"/ 66.5 mm �— 2.62"/ '1 66.5 mm l' 7.25"/ 184.2 mm II IIIIIIIIIII III 5.50"/ 6.577 l tIhiiliilIAIII�llhll �` 139.7 mm _ _ • 5.00"/ 166.9 mm • 127.0 mm 9.0"/229 mm straight reducer 4.83"/ = 3.25"/ =_ 122.7 mm = = 82.6mm = _ I1111111111111111111111111 == ism 4111111111111111111111111111 � a IIIIIIIIIIIIIIIIIIIIIIIIIII I —13.0"/330 mm straight reducer Short 90°elbow reducer Long 90°elbow reducer NOTE • The Short 90°elbow reducer is typically used with concealed sprinklers while the longer 90°elbow is typically used in the installation of recessed pendent sprinklers. • FM/VdS Approved only. Low Profile 'II All = = 4.59"/ 5.25"/ 133 mm 3.507 3.63'/ E. = 116 mm 2.84"/ 89mm 92mm = _ 1.88"/ - = 72 mm = _ 48mm = _ 1.4"/ 1.4"/ 36mm 36 mm Short 90°elbow reducer Long 90°elbow reducer NOTE • Style AB11:When low profiles elbows are with the Style AB11 bracket,the Low Profile Short Elbow is typically used with concealed sprinklers while the Low Profile Long Elbow is typically used in the installation of recessed pendent sprinklers. No. 116 CPVC Adapter EtoE NOTES • E to E is 3.0"/76.0 mm • The No. 116 CPVC Adapter has 2 ft.(0.6 m)EQL of 1"Schedule 40 pipe. • • 10.85 5839 Rev AL Updated 02/2022 ©2022 Victaulic Company.All rights reserved. victaulic.com • •4.1 DIMENSIONS VicFlex Brackets Style AB2 • Suspended Ceilings • Hard-Lid Ceilings Item Description 1 247610mm or 4871219 mm Square Bar 2 Patented Vertically Adjustable Center Bracket ilk 3 End Bracket NOTE 1 • Both sizes FM/VdS/LPCB Approved,cULus listed Style AB3 _ • Surface Mount Applications / V� i,I/_ • FM/LPCB Approved Ole , � „,i Style AB4 • Hard-Lid Ceilings with Hat furring hc% channel grid system Item Description 1 247610 mm or 4871219 mm Square Bar 2 Patented Vertically Adjustable Center Bracket 3 End Bracket for Hat Furring Channel NOTE e, • Both sizes FM/VdS/LPCB Approved,cULus listed. • • 10.85 5839 Rev AL Updated 02/2022 ©2022 Victaulic Company.All rights reserved. victaulic.com • 4.2 DIMENSIONS VicFlex Brackets Style AB5 • Hard-Lid Ceilings Item Description 1 24"/610 mm or 48"/1219 mm Square Bar 2 I Patented Vertically Adjustable Center Bracket 3 ] End Bracket <� NOTE 0 • Both sizes FM/VdS/LPCB Approved,cULus listed. •cam Style AB7 • Suspended Ceilings • Hard-Lid Ceilings Item - Description 1 24/610 mm or 48"/1219 mm Square Bar 2 Patented 1-Beer Center Bracket • O 3 End Bracket NOTE • Both sizes FM/VdS/LPCB Approved. yj '10 Style AB7 Adjustable © `� • Suspended CeilingsI[?1 • Hard-Lid Ceilings Item Description 1 700 mm or 1400 mm Square Bar 2 Patented 1-Bee2®Center Bracket 3 1 End Bracket(adjustable) NOTE it • Both sizes FM/VdS/LPCB Approved. • • 10.85 5839 Rev AL Updated 02/2022 ©2022 Victaulic Company.All rights reserved. victaulic.com • • 4.3 DIMENSIONS VicFlex Brackets Style AB10 o • Suspended ceilings • Armstrong®TechZone'M 49 '(� u Item Description 1 1 6"/152 mm Square Bar 2 Patented 1-Beer Center Bracket 3 -----._ End Bracket ------ NOTE • FM/VdS/LPCB Approved,cULus listed. Style AB11 1lei • Suspended ceilings I � • Hard-Lid ceilings Item Description 1 „ 24"/610 mm or 48'71219 mm Square Bar �iy O 2 Patented 1-Beer Center Bracket 3 End Bracket ID NOTE �o ` . • FM/VdS Approved,cULus listed. `/ ir Style AB12 • Suspended ceilings \ ; ram. „ • Hard-Lid ceilings * ''/ Item Description 1 _._-- Style AB12 Bracket Bod ram' �'•,� 0 2 #2 Square Drive Set Screw I�, NOTE • FM/VdS Approved. • • 10.85 5839 Rev AL Updated 02/2022 ©2022 Victaulic Company.All rights reserved. victaulic.com 4.3 DIMENSIONS (CONTINUED) VicFlex Brackets Style ABBA o • Floor-above mount � • Cantilever mount • Temporary mount in exposed ceilings Item Description 1 Style ABBA Mounting Plate 2 Style ABBA Square Bar 3 Cap Screw,Serated Flange,M6 x 1 x 20, T25 Torx Drive Recessed' 4 Style ABMM Bracket Body _ o �,� Cap Screw,Serated Flange,M6 x 1 x 15.24 5 T25 Torx Drive Recessed NOTE • FM Approved. Style ABMM �� .. • Surface mount • Stand-off mount Item Description ����� l 1 Style ABMM Bracket Body_ j 2 Cap Screw,Serated Flange,M6 x 1 x 15.24, T25 Torx Drive Recessed NOTE • FM Approved. • • 10.85 5839 Rev AL Updated 02/2022 ©2022 Victaulic Company.All rights reserved. victaulic.com '4.4 DIMENSIONS Clearances Series AH2 Braided Hose and Style AB2 Bracket / See Table L Bracket Assembly Style AB2 -_/ Jib , 1:� ■ • ` = 111 mm 23/8760.33 mm L;2 I 1F"/50.80 mm I� _ ::._, L� — Typical i = 1;:ill\ ceiling tile Ili •J — 1.7"/43 mm , �' 1 " • '- Typical ceiling grid �•i//! �0 i�.� //� gr� 1 . %- I' - i /�/! !/ .A ��l � V Finished � surface 111$ See note 24"/610 mm or 48"/1219 mm li on Center V27073/4"/19 MM MAX.RECESS V2707 MAX.EXTENSION Hose Clearance Chart Straight Reducer Long Elbow Short Elbow V2707 V3802 V2707 V3802 3/a" 1 " 3/a" 1/2' V2707 V3802 V2707 V3802 Max Recess Max Recess Max Recess Max Recess 3/4"Max Recess 1/2"Max Recess 3/a"Max Recess ' "Max Recess inches inches inches inches inches inches inches inches mm mm mm mm mm mm mm mm °R"Minimum 2.0 3.0 7.0 _ Bend Radius 50 80 175 "A"Minimum Required 8.6 10.1 9.6 11.1 13.6 15.1 5.8 5.8 Installation 218 269 244 281 345 383 147 147 Space NOTE • Variations of ceiling grids,sprinkler heads,brackets,and hoses are permitted but may result in clearance differences from the figures above. • • 10.85 5839 Rev AL Updated 02/2022 ©2022 Victaulic Company.All rights reserved. victaulic.com • • 4.5 DIMENSIONS Clearances Series AH2 Braided Hose and Style AB2 Bracket A IR IIII. See chart A /_ / See Chart T 7 . ,__i k Bracket #10 Screw r _ Assembly = Style AB2 1 / 21W/68mm — 1 8"/45 mm _max.hole I.. IF I •,•, 2 e''/60 mm � `� :- • min.hole 2°x 4° $1=1 , Lj Stud I ��I,,r { 3/i/ ¶ r �� r � ..� II 89 mm •::t I toy i Finished 5/8716 mm j Typical 16"/406 mm C/C ceiling Typical drywall V38 Y"/13 mm MAX.RECESS V38 MAX.EXTENSION Hose Clearance Chart Straight Reducer V2707 V3802 V2709 V2707 V3802 V2709 V2707 V3802 V2709 3/4"I20mm ' "I13mm 3/4"I20mm 3/4"I20mm l "I13mm 3/4"I20mm 3/4"I20mm 1/2"I13mm 3/4"I20mm Max Recess" Max Recess Sidewall Max Recess Max Recess Sidewall Max Recess Max Recess Sidewall inches inches inches inches inches inches inches inches inches mm mm mm mm mm mm mm mm mm "R"Minimum 2.0 3.0 7.0 Bend Radius 50 80 175 "A'Minimum Required 6.2 7.6 6.1 7.2 8.6 7.1 11.2 12.6 11.1 Installation 158 193 155 183 218 180 285 320 282 Space Hose Clearance Chart Long Elbow Short Elbow V2707 V2709 V3802 3/4"120mm 3/4"120mm 1/2"I 13mm Max Recess Sidewall Max Recess inches inches inches mm mm mm "R"Minimum — Bend Radius "A"Minimum Required 3.3 3.6 3.3 Installation 84 91 84 ISpace NOTE • Variations of ceiling grids,sprinkler heads,brackets,and hoses are permitted but may result in clearance differences from the figures above. • • 10.85 5839 Rev AL Updated 02/2022 ©2022 Victaulic Company.All rights reserved. victaulic.com •4.6 DIMENSIONS Clearances Series AH2 Braided Hose and Style AB4 Bracket 4141 : R _ See chart /M_ 1S A r7 See Chart Bracket assembly Style AB4 4.1"/ 23/e'/60 mm I .-- Typical Hat iim =■.l_ — 104 mm max.hole Channel i = 2751 mm #10 Screw grid i -a:19 min.hole lq,:!_l_. _ME_ u.V.0 a"/23 mm Al Finished I� ceiling 5 mm _ S Typp icalcal drywall Typical16"/406 mm C/C V27 3/4"/19 mm MAX.RECESS V27 MAX.EXTENSION Hose Clearance Chart Straight Reducer Long Elbow Short Elbow V2707 V3802 V2707 V3802 3A" 1h" 3/4' 1/2" V2707 V3802 V2707 V3802 Max Recess Max Recess Max Recess Max Recess 3A"Max Recess 1/2"Max Recess 3A"Max Recess 1/2"Max Recess inches inches inches inches inches inches inches inches mm mm mm mm mm mm mm mm "R"Minimum 2.0 2.0 3.0 ' 3.0 7.0 7.0 _ Bend Radius 50 50 80 80 175 175 "A"Minimum Required 8.8 10.2 9.8 11.2 13.8 15.2 8.0 5.9 Installation 224 259 249 285 351 386 203 150 Space NOTE Variations of ceiling grids,sprinkler heads,brackets,and hoses are permitted but may result in clearance differences from the figures above. • • 10.85 5839 Rev AL Updated 02/2022 ©2022 Victaulic Company.All rights reserved. victaulic.com • 4.7 DIMENSIONS Clearances Series AH2 Braided Hose and Style AB5 Bracket A R ■■ See chart A See chart WAS 'lil, rim Bracket ,Im1I assembly Style ABS ' 57 mm [ 1 _..!L•I 1 . umi =IIll=--- 23/a"/60 mm 2"x 4' i I =■�- I max hole metal stud BS/e,/ 4-2"/51 mm-4. 92 mm min.hole I i 1 -- I lbFinished 5/8"/16 mm ceiling Typ.Drywall Typical 16"/406 mm C/C V27 3/4"/19 mm MAX.RECESS V27 MAX.EXTENSION Hose Clearance Chart Straight Reducer "V2707 V3802 V2709 V2707 V3802 V2709 V2707 V3802 V2709 3/4"120mm 1/2'I13mm 3/4"120mm 3/4"120mm ' "113mm WI20mm WI20mm WI13mm 3/4'120mm Max Recess" Max Recess Sidewall Max Recess Max Recess Sidewall Max Recess Max Recess Sidewall inches inches inches inches inches inches inches inches inches mm mm mm mm mm mm mm mm mm "R"Minimum 2.0 3.0 7.0 Bend Radius 50 80 175 "A"Minimum Required 6.0 7.7 6.1 7.0 8.7 7.1 11.0 12.7 11.1 Installation 158 196 155 178 221 180 279 323 282 Space Hose Clearance Chart Low-Profile Long Elbow Long Elbow Short Elbow V2707 V3802 V2709 V3802 V3802 3/4"120mm 1/2"113mm WI20mm W I13mm W I13mm Max Recess Max Recess Sidewall Max Recess Max Recess inches inches inches inches inches mm mm mm mm mm "R"Minimum _ Bend Radius "A"Minimum Required 3.5 4.9 3.6 2.9 3.3 Installation 89 124 91 74 84 Space NOTE • Variations of ceiling grids,sprinkler heads,brackets,and hoses are permitted but may result in clearance differences from the figures above. • • 10.85 5839 Rev AL Updated 02/2022 ©2022 Victaulic Company.All rights reserved. victaulic.com • • 4.8 DIMENSIONS Clearances Series AH2 Braided Hose and Style AB11 Bracket (LOW PROFILE SOLUTION) 23/760 mm 21i6'768 mm Bracket •j max.hole max.hole Assembly ,I�I'11 2"/51 mm 2/8"/60 mm Style AB1 1 A I.." y min.hole min.hole See Chart 0■ li0 3.0"/ 76 mm 11111 E_ �_ lit • 111 1.7"/43 mm 4IY• im Finished 4I1i Typical 5/8/15.9 mm ceiling face a ceiling grid Typical ceiling tile See Note 24"/610 mm or V27 V38 48"/1219 mm on center Pendent Hose Clearance Chart Low-Profile Low-Profile Long Elbow Short Elbow V2707 V3802 '/a"I20mm 1/2'I13mm Max Recess" Max Recess inches inches mm mm "A"Minimum Required 4.0 3.9 Installation 102 99 Space NOTE • Variations of ceiling grids,sprinkler heads,brackets,and hoses are permitted but may result in clearance differences from the figures above. • • 10.85 5839 Rev AL Updated 02/2022 ©2022 Victaulic Company.All rights reserved. victaulic.com 4.9 DIMENSIONS Clearances Style AB12 and ABBA Bracket Suspended Ceiling Grid with Recessed Sprinkler with Suspended Ceiling Grid with Recessed Sprinkler and Low Profile Short Elbow Straight 5.75"/140mm Reducer • • i i Unfinished i Ceiling Face; 1 Vs inch/ 29 mm j • -- -I Nominal length 147355.6 mm I utue 311' T � Unfinished Wiii 1. See Table 1 Ye inch/ Ceiling Face l �7 �� : Il 29 mm r r h inch/ by 3mm -- �� • T'k inch, , � "A" -�- , -a 3mm pp I See Table {fir. "R"See Table ���lint $J�' lAl_:� ''B''See Table L=:J QJ -- tire _� E_ I R I � %%1iAl I�` l�1 /6„!/l%//%%%%%, "i/D i -mm- i O%.;/:II�r i1�1 D%%%O%/O%//%O// ;�� Finished Face of rye ��1� Finished Face of /e-inch/16-mm 4" /zinch/16-mm Typical Ceiling Typical Ceiling V2707'4"/12.7 mm MAX.RECESS V2707'/."/19 mm MAX.RECESS Low Profile Low Profile Standard Standard Standard Dimension Short Elbow Long Elbow Short Elbow Long Elbow Straight Reducer 3/4'119 mm '/719 mm 3/a"/19 mm 3/4"/19 mm 3/4719 mm Recessed* Concealed Recessed Concealed Recessed Concealed Recessed Concealed Recessed Concealed inches inches inches inches inches inches inches inches inches inches mm mm mm mm mm mm mm mm mm mm A Minimum Required 4.0 5.5 5.6 7.2 5.9 7.5 7.7 9.3 15.0 16.6 Installation Space 101.6 139.7 142.2 182.9 149.9 190.5 195.6 236.2 381.0 421.E Distance from Top of 0.5 2.0 1.5 1.5 1.5 1.5 3.0 3.0 3.0 3.0 B Typical Ceiling Tile to 12.7 50.8 38.1 38.1 38.1 38.1 76.2 76.2 76.2 76.2 Bottom of Gate *Adjustability will be limited Style ABMM Bracket Stand-off Dimensions 110.0/01‘162.22'7 56 mm� I _ • I• �� CI�1,_> �) o / • 7mm 3.93"/ • 75 mm 100 mm 1 O t111 'Q)11 ll(,' 100 mm o,IW o ® • • 10.85 5839 Rev AL Updated 02/2022 ©2022 Victaulic Company.All rights reserved. victaulic.com 4.10 DIMENSIONS Clearances Style AB3 and ABMM Bracket Surface Mount Application with Recessed Sprinkler A �- ^ 33/4/ 95.3mm 11_ 4 f 1 3 =2 _ j B 23/8"/60 mm max.hole 2"/51 mm min.hole Hose Clearances inches inches inches inches inches inches inches inches inches inches Dimension mm mm mm mm mm mm mm mm mm mm Wall Thickness 2 4 6 8 10 2 4 6 8 10 50 100 150 200 250 50 100 150 200 250 Outlet length 5.75 9 13 5.75 9 13 9 13 13 13 575 9 13 5.75 9 13 9 13 13 13 "B" 146.1 228.6 330.2 146.1 228.6 330.2 228.6 330.2 330.2 330.2 146.1 228.6 330.2 146.1 228.6 330.2 228.6 330.2 330.2 330.2 Hose Clearance 11.6 14.8 18.8 9.6 12.8 16.8 10.8 14.8 12.8 10.8 12.6 15.8 19.8 10.6 13.8 17.8 11.8 15.8 13.8 11.8 C" 294 376 478 243 325 427 275 376 325 275 319 402 503 268 351 452 300 402 351 300 Bend Radius 7 8 "R" 175 200 NOTE • Variations of ceiling grids,sprinkler heads,brackets,and hoses are permitted but may result in clearance differences from the figures above. • • 10.85 5839 Rev AL Updated 02/2022 ©2022 Victaulic Company.All rights reserved. victaulic.com 4.11 DIMENSIONS BRANCHLINE CLEARANCES Series AH2 Braided Hose with Style 922 threaded outlet Series AH2-CC Braided Hose with Style 922 grooved outlet R See chart R See chart Nom A ■■ A .. See chart See chart II ._-t- or /PC) IIII .1 II `'`���`- Style 922 Style 922 Threaded Y poi" Mechanical Tee Grooved __„,, _ Outlet K _ MechancalTee � �\ . Outlet . ( o-'- -:-.-. ) 111 II— r. .._,.. i•ER 112750mm \ / 2"/50 mm Hose Clearance Chart Hose Clearance Chart Dimension Dimension inches inches inches inches inches inches inches inches inches inches mm mm mm mm mm mm mm mm mm mm Minimum 3 4 5 6 7 Minimum 3 4 5 6 7 R Bend Radius 80 100 125 150 175 R Bend Radius 80 100 125 150 175 11.7 A Min. 238 263 289 1 314 339 A Min. 7.79 222 247 2 8.7 9.7073 298 10.85 5839 Rev AL Updated 02/2022 ©2022 Victaulic Company.All rights reserved. victaulic.com 4.12 DIMENSIONS BRANCHLINE CLEARANCES Series AH2 Braided Hose with female threaded outlet Series AH2-CC Braided Hose with grooved outlet R See chart R See chart ME mi . A ME .. See chart A -= See chart ii 1, ill 1 IQ IIIIFemale Threaded � Weld Outlet MR r� ria No.142 Grooved Weld Outlet ilivigr 2"/50 mmlimul J 2^/50 mm Hose Clearance Chart Hose Clearance Chart Dimension Dimension inches inches inches inches inches inches inches inches inches inches mm mm mm mm mm mm mm mm mm mm R Minimum 3 4 5 6 7 R Minimum 3 4 5 6 7 Bend Radius 80 100 125 150 175 Bend Radius 80 100 125 150 175 A Min. 9.4 10.4 11.4 12.4 13.41 A Min. 8.1 9.1 10.1 11.1 12.1 239 264 290 315 341 205 231 256 281 307 • • 10.85 5839 Rev AL Updated 02/2022 ©2022 Victaulic Company.All rights reserved. victaulic.com • 5.0 PERFORMANCE — FRICTION LOSS DATA US Series AH2 and AH2-CC Braided Hoses with Straight 5.75"/140 mm Reducers cC LISTED Style AB2, AB4, AB5 and AB10 Brackets Hose Reducer UL Equivalent Length of Length Nominal Outlet Size 1.733.7mm Sch.40 pipe inches inches feet mm Type DN meters Max Bends 90 Straight DN15 4.6 3 9 10 Straight DN15 4.9 4 790 Straight DN20 5.8 3 31374 790 Straight DN20 6010 4 36 9 5 Straight DN15 5.5 915 Straight DN15 6.4 5 53 Straight DN20 21.0 4 3 915 2 .0 Straight DN20 730 5 1220 Straight1/2 0 3 DN15 6.4 1220 Straight DN15 9.8 8 48 1220 Straight DN20 �... -- 7.9 — — 3 1220 Straight DN20 11.03 8 1 560 Straight DN15 81/2 .0 3 1525 Straight DN15 14.0 10 1525 Straight DN20 872.0 3 60 _._..._ ..._ 6 15025 Straight DN20 14.0ih. 10 1830 Straight 72 DN15 — — 31.0 4 3— — _.. --_ w. .:..... 1830 Straight DN15 16 8 12 -- —1872 30 Straight__— DN20 g 0 3 _._._ ....__._._... __.. ..._.T_<.__. __.....w ._..__�_ _.._._.._e._.. 1830 Straight DN20 18.3 12 • • 10.85 5839 Rev AL Updated 02/2022 ©2022 Victaulic Company.All rights reserved. victaulic.com • 5.0 PERFORMANCE — FRICTION LOSS DATA (CONTINUED) cC us Series AH2 and AH2-CC Braided Hose with 90') Low Profile Elbows LISTED Style AB11 VicFlex Bracket Hose Reducer UL Equivalent Length of Length Nominal Outlet Size 1733.7mm Sch.40 pipe inches inches feet mm Type DN meters Max Bends 31 790 LP Elbow DN15 5.5 180 790 LP Elbow DN15 7430 4 31 790 LP Elbow DN2tl — — — 64 3— 3/4 31 4.0 790 LP Elbow DN20 27.3 4 1/2 915 LP Elbow flN 15 5.8 3 915 36 LP Elbow DN1▪5 7.9 5 915 36 LP Elbow DNZO 73.0 3 36 915 LP Elbow DN20 8.5 5 LP Elbow ▪ — — �0 3 1220 DN15 48 1220 LP Elbow DN15 13.10 8 1220 LP Elbow DN20 9 7 3 1220 LP Elbow DN20 12.8 8 60 — — 1/2 2.0 1525 LP Elbow • flN15' 8.5 3 60 1525 LP Elbow DN15 14.9 10 60 1525 LP Elbow DN206 9.4 3 15025 LP Elbow DN20 150.02 10 72 LP Elbow 1/2 31.0 3 1830 DN15 ` 9.4 183072 LP Elbow DN15 19.8 12 72 1830 LP Elbow DN20 61311.0 3 34 1830 0 72 LP Elbow DN20 19 if 12 • 10.85 5839 Rev AL Updated 02/2022 ©2022 Victaulic Company.All rights reserved. ' victaulic.com • • 5.0 PERFORMANCE - FRICTION LOSS DATA (CONTINUED) Series AH2 and AH2-CC Braided Hoses Equivalent Length Design Guide Equivalent length values at various numbers of 90 degree bends at 2751 mm center line bend radius Nominal Outlet 1 2 3 4 5 6 7 8 9 10 11 12 Length Size Bend Bends Bends Bends Bends Bends Bends Bends Bends Bends Bends Bends inches inches feet feet feet feet feet feet feet feet feet feet feet feet mm DN meters meters meters meters meters meters meters meters meters meters meters meters 31 1/4 11.0 13.0 15.0 16.0 - - - - - - - 790 DN15 3.4 4.0 4.6 4..9 31 3/4 12.0 14.0 19.0 20.0 _ 790 DN20 3.7 4.3 5.8 6.1 36 1h 14.0 16.0 18.0 19.0 21.0 _ 915 DN15 4.3 4.9 " 5.5 5.8 6.4 - - - - 36 3/4 17.0 19.0 21.0 22.0 23.0 - - 915 DN20 5.2 5.8 6.4 6.7 7.0 48 94 18.0 19.0 21.0 23.0 25.0 27.0 30.0 32.0 : _ _ _ _ 1220 DN15 5.5 5.8 6.4 7.0 , 7.6 8.2 9.1 9.8 48 3A 21.0 24.0 26.0 28.0 31.0 33.0 35.0 37.0 - - 1220 DN20 6.4 7.3 7.9 8.5 9.4 10.1 10.7 11.3 60 1/2 21.0 24.0 27.0 30.0 32.0 35.0 37.0 40.0 43.0 46.0 - - 1525 DN15 6.4 7.3 8.2 9.1 9.8 10.7 11.3 12.2 13.1 14.0 60 3/4 23.0 25.0 27.0 29.0 32.0 34.0 37.0 40.0 43.0 46.0 - 1525 DN20 7.0 7.6 8.2 8.8 9.8 10.4 11.3 12.2 13.1 14.0 72 'h 27.0 29.0 31.0 34.0 37.0 40.0 43.0 46.0 48.0 50.0 52.0 55.0 1830 DN15 8.2 8.8 9.4 10.4 11.3 12.2 13.1 14.0 14.6 15.2 15.8 16.8 72 3/4 26.0 28.0 30.0 33.0 37.0 40.0 44.0 48.0 51.0 54.0 57.0 60.0 1830 DN20 7.9 8.5 9.1 10.1 11.3 12.2 13.4 14.6 15.5 16.5 17.4 18.3 NOTES • Values for use with 5.75"/140mm straight reducers. • The values in this table are provided by the manufacturer for reference only.For friction loss data in accordance with the UL Certification,please refer to pages 19 and 20 of this publication. How to use this Design Guide: • For some systems,it may be advantageous for the designer to calculate the system hydraulics using shorter equivalent lengths associated with fewer than the maximum allowable number of bends.In this case,the designer may select a design number of bends for the job and use the associated equivalent length from the design guide to determine the system hydraulics. • It is possible that the actual installed condition of some of the flexible drops may have more bends than the designer selected.When this happens,the design guide may be used to find equivalent lengths based on the actual installed number of bends for particular sprinkler installations.The system hydraulics can be recalculated using actual equivalent lengths to verify the performance of the system. • • 10.85 5839 Rev AL Updated 02/2022 ©2022 Victaulic Company.All rights reserved. victaulic.com_ 5.1 PERFORMANCE - FRICTION LOSS DATA ® Series AH2 and AH2-CC Braided Hoses Style AB2, AB3, AB4, AB5, AB7, AB7 Adj., AB8, AB1O, AB12, ABBA and ABMM VicFlex Brackets Maximum Equivalent Number Length of Length of of 90°Bends Stainless Steel Outlet 1"/33.7mm at 7'7178mm Flexible Hose K-Factor Size Sch.40 Pipe Bend Radius inches inches Imperial mm feet mm S.I. type meters 1h 13.8 15 4.2 31 5.6 Straight 790 8.1 yh 23.5 15 - -- - 90°Elbow 7.1 1/2 15 16.6 36 5.6 Straight 5.1 915 8.1 1 2 15 25.6 90°Elbow 7.8 /2 23.415 '' 48 5.6 Straight 7.1 1220 8.1 1/43 15 30.7 - -- - 90°Elbow 9.3 1/2 15 30.2 60 5.6 Straight 9.2 1525 8.1 1/24 15 35.9 90°Elbow 10.9 37.0 15 11.3 72 5.6 Straight 1830 8.1 ,/2 4 15 41.1 90`Elbow 12.5 20 16.8 31 8.0 Straight 5.1 790 11.5 3/4 2 20 16.8 90°Elbow 5.1 3/4 20 20 36 8.0 Straight 6.0 915 11.5 3/4 2 20 19.7: 90`Elbow 6.0 20 27.8 48 8.0 Straight 8.4 1220 11.5 3/a ..._._ 3 20 26.6 90°Elbow 8.1 FM NOTES • The Series AH2 hose has been tested and Approved by FM Global for use in wet,dry and preaction systems per NFPA 13, 13R,and 13D and FM data sheets 2-0,2-5,and 2-8.FM 1637 standard for safety include,but are not limited to,pressure cycling,corrosion resistance,flow characterisitics,vibration resistance,leakage,mechanical and hydrostatic strength. • EXAMPLE:A 48-inch hose installed with two 30°bends and two 90°bends is permitted and considered equivalent to the data in the table shown above. In this example,the total number of degrees is 240°,which is less than the allowable 270°. • • 10.85 5839 Rev AL Updated 02/2022 ©2022 Victaulic Company.All rights reserved. victaulic.com • • 5.1 PERFORMANCE- FRICTION LOSS DATA (CONTINUED) Series AH2 and AH2-CC Braided Hoses Style AB2, AB3, AB4, AB5, AB7, AB7 Adj., AB8, AB10, AB12, ABBA and ABMM VicFlex Brackets Maximum Equivalent Number Length of Length of of 90°Bends Stainless Steel Outlet 1"/33.7 mm at 7'7178 mm Flexible Hose K-Factor Size Sch.40 Pipe Bend Radius inches inches Imperial mm feet mm S.I. type meters 1/4 35.7 20 10.9 60 8.0 Straight' 4 1525 11.5 3,4 20 33.6 ` 90°Elbow 10.2 3/4 20 43.5 72 8.0 Straight 13.2 4 1830 11.5 3/4 40.6 20 12.2 90°Elbow 16.5 20 5.0 31 11.2 Straight 790 1 V46.1 2 20 17.8 90'Elbow 5.4 19.5 20 5.9 36 11.2 Straight 915 16.1 3A 2 20 20.7 90°Elbow 6.3 4/4 26.7 70 8.1 48 11.2 Straight 1220 16.1 3 V4 20 27.9 90'Elbow8.5 20 33.9 60 11.2 Straight 10.3 4 1525 16.1 3A 35 20 10.7 90°Elbow 3/4 41.3 20 125 72 11.2 Straight 1830 16.1 3 4 /, 20 42.2 90'Elbow 12.8 3A 20 14.9 31 14.0 Straight 4.5 790 20.2 3 2 /4 20 15.5 90°Elbow 4.72 FM NOTES • The Series AH2 hose has been tested and Approved by FM Global for use in wet,dry and preaction systerris per NFPA 13, 13R,and 13D and FM data sheets 2-0,2-5,and 2-8.FM 1637 standard for safety include,but are not limited to, pressure cycling,corrosion resistance,flow characterisitics,vibration resistance,leakage,mechanical and hydrostatic strength. • EXAMPLE:A 48-inch hose installed with two 30°bends and two 90°bends is permitted and considered equivalent to the data in the table shown above.In this example,the total number of degrees is 240°,which is less than the allowable 270°. • • 10.85 5839 Rev AL Updated 02/2022 ©2022 Victaulic Company.All rights reserved. victaulic.com • 5.1 PERFORMANCE— FRICTION LOSS DATA (CONTINUED) ® Series AH2 and AH2-CC Braided Hoses Style AB2, AB3, AB4, AB5, AB7, AB7 Adj., AB8, AB10, AB12, ABBA and ABMM VicFlex Brackets Maximum Equivalent Number Length of Length of of 90°Bends Stainless Steel Outlet 1'733.7mm at 7'7178mm Flexible Hose K-Factor Size Sch.40 Pipe Bend Radius inches inches Imperial mm feet mm S.I. type meters 34 19.4 20 5.9 36 14.0 Straight 2 915 20.2 44 19.6 20 5.9 90'Elbow 3/4 30.3 20 9.2 48 14.0 Straight 1220 20.2 3 3 /4 20 29.5 90°Elbow 8.9 ---- — - � 33.9 20 10.3 60 14.0 Straight 4 1525 20.2 'ti 34.1 20 10.4 90'Elbow 3/4 20 37.5 72 14.0 Straight 11.4 1830 20.2 3 4 /4 20 38.6 90°Elbow 11.7 FM NOTES • The Series AH2 hose has been tested and Approved by FM Global for use in wet,dry and preaction systems per NFPA 13,13R,and 13D and FM data sheets 2-0,2-5,and 2-8.FM 1637 standard for safety include,but are not limited to,pressure cycling,corrosion resistance,flow characterisitics,vibration resistance,leakage,mechanical and hydrostatic strength. • EXAMPLE:A 48-inch hose installed with two 30°bends and two 90°bends is permitted and considered equivalent to the data in the table shown above. In this example,the total number of degrees is 240°,which is less than the allowable 270°. 10.85 5839 Rev AL Updated 02/2022 ©2022 Victaulic Company.All rights reserved. victaulic.com • • 5.2 PERFORMANCE - FRICTION LOSS DATA ® Series AH2 Braided Hose with 90° Low Profile Elbows Style AB5, AB11, AB12, ABBA and ABMM VicFlex Bracket Maximum Equivalent Number Length of Length of of 90°Bends Stainless Steel Outlet 1"/33.7mm at 7'I178mm Flexible Hose K-Factor Size Sch.40 Pipe Bend Radius inches Imperial inches feet mm S.I. mm meters 31 5.6 'i4 13.7 2 790 8.1 15 4.2 36 5.6 1/2 17.0 2 915 8.1 15 5.2 48 5.6 1 25.0 3 1220 8.1 15 7.6 60 5.6 1 33.0 4 1525 8.1 15 10.1 72 5.6 '1/2 41.1 4 1830 8.1 15 12.5 31 8.0 3A 13.6 2 790 11.5 20 4.14 36 8.0 3/4 16.9 2 915 11.5 20 5.2 48 8.0 3/a 27.8 3 1220 11.5 20 8.5 60 8.0 3A 32.6 4 1525 115 20 9.9 72 8.0 3A 40.6 4 1830 11.5 20 12.4 31 11.2 % 13.7 2 790 16.1 20 4.2 36 11.2 3A 17.0 2 915 16.1 20 5.2 48 11.2 3A 24.9 3 1220 16.1 20 7.6 60 11.2 3/4 32.9 4 1525 16.1 20 10.0 72 11.2 3/a 40.9 4 1830 16.1 20 12.5 31 14.0 3A 13.5 2 790 20.2 20 4.1 36 14.0 3/a 16.8 2 915 20.2 20 5.1 48 14.0 3/4 24.7 3 1220 20.2 20 7.5 60 14.0 3/4 32.7 4 1525 20.2 20,_. :...._ ._._ 9.9_.. 72 14.0 3A 40.7 4 1830 20.2 20 12.4 FM NOTES • The Series AH2 hose has been tested and Approved by FM Global for use in wet,dry and preaction systems per NFPA 13, 13R,and 13D and FM data sheets 2-0,2-5,and 2-8.FM 1637 standard for safety include,but are not limited to,pressure cycling,corrosion resistance,flow characterisitics,vibration resistance, leakage,mechanical and hydrostatic strength. • EXAMPLE:A 48-inch hose installed with two 30°bends and two 90°bends is permitted and considered equivalent to the data in the table shown above. In this example,the total number of degrees is 240°,which is less than the allowable 270°. 10.85 5839 Rev AL Updated 02/2022 ©2022 Victaulic Company.All rights reserved. victaulic.com • • 5.3 PERFORMANCE- FRICTION LOSS DATA VdS Series AH2 and AH2-CC Braided Hose Style AB2, AB4, AB5, AB7, AB7 Adj., AB8, AB10, AB11 and AB12 Brackets Equivalent Length of Length of steel pipe according to Stainless Steel Outlet EN 10255 DN 25 Maximum Number Flexible Hose Size (33,7 x 3,25) of 90 Bends at mm DN meters 3.776.2mm Bend inches inches feet Radius DN 15 790 1/2 5.5 3 31 DN20 18.0 3/4 DN15 915 1/2 6.4 3 36 DN20 21.0 3/4 DN15 1220 1/2 83 3 48 DN20 27.9 14 DN15 1525 1/2 10.7 4 60 DN20 35.1 3/4 DN15`' 1830 Yz 12.8 4 72 DN20 42.0 314 VdS Ceiling Manufacturers List AB2,AB7,AB10,AB11 AB4 AB5,AB8 1.AMF No specific approval 1.Hilti 2.Armstrong 2.Knauf 3.Chicago Metallic 3.Lafarge 4.Dipling 4.Lindner 5.Durlum 5.Rigips 6.Geipel 7.Gema-Armstrong 8.Hilti 9.Knauf 10.Lafarge 11.Linder 12.Odenwald 13.Richter 14.Rigips 15.Rockfon Pagos 16.Suckow&Fischer 17.USG Donn • • 10.85 5839 Rev AL Updated 02/2022 ©2022 Victaulic Company.All rights reserved. victaulic.com • 5.3 PERFORMANCE- FRICTION LOSS DATA Series AH2 and AH2-CC Braided Hose Series AH2 Braided Hose LPCB• Style AB2, AB3, AB4, AB5, AB7, AB8, Style AB2, AB3, AB4, AB5, AB7, AB8, AB1O P as and AB1O Brackets ® and AB12 Brackets Cerl/L1011/01 Length of Equivalent Length Maximum Stainless of steel pipe Number of Equivalent Length of Steel according to 90 Bends at Length of 1/33.7 mm Sch.40 Pipe Flexible Outlet EN 10255 DN 25 3%76.2 mm Flexible Hose Size (33,7 x 3,25) Bend Radius Hose Straight Configuration Bend Configuration mm mm inches meters mm meters meters inches type feet inches feet feet 15mm , ` 790 Straight 1.8 2 790 0.87 2.70 31 20mm 6.0 ( 31 2.9 8.9 31a Straight 15mm 1/2 915 Straight 3.6 3 915 1.00 2.80 36 20mm 11.9 36 3.3 9.2 3/4 Straight 15mm Yz 1220 Straight 4.3 3 1220 2.23 4.66 48 20mm 14.0 y 48 7.3 15.3 3/a Straight 15mm ' 1525 Straight 4.1 3 1525 2.90 6.5 60 20mm 13.6 60 9.5 21.3 3A Straight 15mm 'h 1830 Straight 5.5 3 1830 3.31 7.16 72 20mm 18.1 72 10.9 23.5 4/4 Straight CCCF NOTE • Friction loss data is in accordance with GB5135.16 tested at a flow rate of 114 liters per minute(30 gallons per minute). • • 10.85 5839 Rev AL Updated 02/2022 ©2022 Victaulic Company.All rights reserved. victaulic.com 6.0 NOTIFICATIONS 111 ■ • Read and understand all instructions before attempting to install 47, • any Victaulic products. • Always verify that the piping system has been completely depres- 0surized and drained immediately prior to installation, removal, adjustment, or maintenance of any Victaulic products. • Wear safety glasses, hardhat, and foot protection. • These products shall be used only in fire protection systems that are designed and installed in accordance with current, applicable National Fire Protection Association (NFPA 13, 13D, 13R, etc.) standards, or equivalent standards, and in accordance with applicable building and fire codes. These standards and codes contain im- portant information regarding protection of systems from freezing temperatures, corrosion, mechanical damage, etc. • The installer shall understand the use of this product and why it was specified for the particular application. • The installer shall understand common industry safety standards and potential consequences of improper product installation. • It is the responsibility of the system designer to verify suitability of 300-series stainless steel flexible hose for use with the intended fluid media within the piping system and external environments. • The effect of chemical composition, pH level, operating temperature, chloride level, oxygen level, and flow rate on 300-series stainless steel flexible hose must be evaluated by the material specifier to confirm system life will be acceptable for the intended service. • It is the responsibility of the owner of a building or their authorized agent to provide the sprinkler system installer with any knowledge that the water supply might be contaminated with or conducive to the development of micro- biologically influenced corrosion (MIC), including as required by NFPA 13. Failure to identify adverse water quality issues may affect the VicFlex product and void the manufacturer's warranty. Failure to follow these instructions could cause product failure, resulting in serious personal injury and/or property damage. Victaulic VicFlex Series AH2 and AH2-CC Flexible Sprinkler Fittings may be painted provided the paint is compatible with stainless steel and zinc-plated carbon steel or ductile iron. Care should be taken to ensure the sprinkler and associated escutcheon or coverplate are not painted. Victaulic VicFlex Series AH2 and AH2-CC penetrating through non-fire rated gypsum wall (drywall)will function as designed, provided the components are installed in accordance with the respective installation instructions referenced in this document. • 10.85 5839 Rev AL Updated 02/2022 ©2022 Victaulic Company.All rights reserved. victaulic.com 7.0 REFERENCE MATERIALS -CHARACTERISTICS VicFlex Maximum Load Values Series AH2 Hose with 24" Bracket Actual Length Total Load Max.Uniform Load ft Model Size m lb N lb/linear ft N/linear m 31/790 0.$ 5.2 23 2.6 38 36/915 9 5.5 25 2.8 40 0. 48/1220 1.2 6.3 28 3.1 46 60/1525 15 7.0 31 3.5 51 72/1830 1 8 7.7 34 3.9 57 Series AH2 Hose with 48" Bracket Actual Length Total Load Max.Uniform Load ft Model Size m lb N lb/linear ft N/linear m 2.6 31/790 0.8 6.1 27 1.5 22 36/915 9 6.4 29 1.6 23 0. 48/1220 1.2 7.2 32 1.8 26 60/1525 1 5 7.9 35 2.0 29 72/1830 1.8 8.7 39 2.2 32 Total Load is defined as the sum of the weights of the following: • water-filled flexible sprinkler hose with threaded end fittings, including a typical fire sprinkler • bracket assembly (any applicable Victaulic bracket model of the relevant associated size) ASTM C 635: Suspension System Load-Carrying Capabilities (excerpted) Actual Length Min.Allowable Uniform Load Suspension System ft/m lb/linear ft N/linearm Light 5.0 75.7 Direct Hung Intermediate 12.0 181.0 Heavy 16.0 241.7 SUMMARY: All direct-hung suspension system duty classifications per ASTM C 635 are able to withstand the maximum water-filled weight of the VicF/ex sprinkler hose and bracket. • 10.85 5839 Rev AL Updated 02/2022 ©2022 Victaulic Company.All rights reserved. victaulic.com 7.0 REFERENCE MATERIALS —CHARACTERISTICS (CONTINUED) • Flexible Hose In-Plane Bend Characteristics One Bend Two Bends Three Bends 2x 2x Minimum Minimum Minimum bend radius ( bend radius bend radius OR Minimum OR bend radius 90° Minimum bend radius Mlnlmum -- — Minimum ( bend radius bend radius Minimum bend radius Minimum bend radius NOTE For out-of-plane (three-dimensional) bends, care must be taken to avoid imparting torque on the hose. I-VlcFlex-AB1-AB2 I-VlcFlex-AB3 I-VicFlex-AB4 I-VlcFlex-AB5 I-VlcFlex-AB7 I-VicFlex-AB12 I-VicFlex-ABBA I-VicFlex-ABMM I-RES • User Responsibility for Product Selection and Suitability Note Each user bears final responsibility for making a determination as to the suitability of This product shall be manufactured by Victaulic or to Victaulic specifications.All products Victaulic products for a particular end-use application,in accordance with industry to be installed in accordance with current Victaulic installation/assembly instructions. standards and project specifications,and the applicable building codes and related Victaulic reserves the right to change product specifications,designs and standard regulations as well as Victaulic performance,maintenance,safety,and warning equipment without notice and without incurring obligations. instructions.Nothing in this or any other document,nor any verbal recommendation, Installation advice,or opinion from any Victaulic employee,shall be deemed to alter,vary,supersede, Reference should always be made to I-VICFLEX-ABt-AB2-AB10,I-VICFLEX-AB4, or waive any provision of Victaulic Company's standard conditions of sale,installation I-VICFLEX-AB7,or I-VICFLEX-AB8 for the product you are installing.Handbooks are guide,or this disclaimer. included with each shipment of Victaulic products for complete installation and assembly Intellectual Property Rights data,and are available in PDF format on our website at www.victaulic.com. No statement contained herein concerning a possible or suggested use of any material, Warranty product,service,or design is intended,or should be constructed,to grant any license Refer to the Warranty section of the current Price List or contact Victaulic for details. under any patent or other intellectual property right of Victaulic or any of its subsidaries or affiliates covering such use or design,or as a recommendation for the use of such Trademarks material,product,service,or design in the infringement of any patent or other intellectual Victaulic and all other Victaulic marks are the trademarks or registered trademarks of property right.The terms"Patented"or"Patent Pending"refer to design or utility patents Victaulic Company,and/or its affiliated entities,in the U.S.and/or other countries. or patent applications for articles and/or methods of use in the United States and/or other countries. • • 10.85 5839 Rev AL Updated 02/2022 ©2022 Victaulic Company.All rights reserved. swi _ T r FIRE PROTECTION Valves and R Components 2017 NW Vaughn St. #10087 Portland, OR 97296 Phone: 360-605-1133 INSTRUCTION SHEET 115 & 115M STANDARD DUTY LOOP HANGERS *Global Part Article Number Nominal Rod Rod Type Static Load Number Pipe Size Size (Ibs) u i 1150050EG 1/2" 1150075EG 3/4" .11 ! ' 1150100EG 1" ANSI/MSS 300 / t?" 1150125EG 1-1/4" Heavy Duty I 1150150EG 1-1/2" 3/8" 1150200EG 2" 1150250EG N/A 2-1/2" 525 1150300EG 3" 1150350EG 3-1/2" 585 1150400EG 4" NFPA Heavy Duty 600 ' 1150500EG 5" 1150600EG 6" 1/2" 1000 1150800EG 8" 1 15M0050EG 597860 1/2" 115 and 115M Series 115M0075EG 597870 3/4" 115M0100EG 597880 1" ANSI/MSS 300 115M0125EG 597890 1-1/4" Heavy Duty 115M0150EG 597900 1-1/2" M10 Flared edges provided on 1/2"through 4" Loop Hanger only 1 15M0200EG 597910 2" 1 15M0250EG 597920 2-1/2" 525 115M0300EG 597930 3" This product provides pipe support for stationary 115M0350EG N/A 3-1/2" 585 non-insulated piping only. 115M0400EG 597940 4" NFPA 600 Heavy Duty 115M0500EG 597950 5" Models 115 and 115M conform with federal specification 115MO600EG 597960 6" M12 1000 WW-H-171 (type 10), Manufacturers Standardization Society *15M0800EG 597970 s" (MSS) SP-58 and SP-69 (type 10). Felt-lined replaces "EG"suffix with "FL". Example 1150050FL. Felt-lined series (FL) provides support for stationary piping with no metal to pipe contact. Rod 1/16" Loop Hanger Installation: 1 from pipe if required O �V r :1111t V ,/t ram' o - i 1 4 or / il , t -,„ J O J 0 WARNING: 1. nVent products shall be installed and used only as indicated in nVent product instruction sheets and training materials.Instruction sheets are available at www.nVent.com and from your nVent customer service representative. 2. nvent products must never be used for a purpose other than the purpose for which they were designed or in a manner that exceeds specified load ratings. 3. All instructions must be completely followed to ensure proper and safe installation and performance. 4. Improper installation,misuse,misapplication or other failure to completely follow nVent's instructions and warnings may cause product malfunction,property damage,serious bodily injury and/or death,and void your warranty. 5. Products that are manufactured using spring steel components shall be used only in a non-corrosive indoor environment. 6. All pipe supports,hangers,intermediate components and structural attachments must ONLY be used as described herein and are NEVER to be used for any other purpose. NOTE:All load ratings are for static conditions and do not account for dynamic loading such as wind,water or seismic loads,unless otherwise noted. The customer is responsible for: a.Conformance to all governing codes. b.The integrity of structures to which the products are attached,including their capability of safely accepting the loads imposed,as evaluated by a qualified engineer. c.Using appropriate industry standard hardware as noted above. SAFETY INSTRUCTIONS: •. All governing codes and regulations and those required by the job site must be observed. Always use appropriate safety equipment such as eye protection,hard hat,and gloves as appropriate to the application. nVent,nVent CADDY,nVent ERICO Cadweld,nVent ERICO Critec,nVent ERICO,nVent ERIFLEX,and nVent LENTON are I' , 1/ owned by nVent or its global affiliates.All other trademarks are the property of their respective owners.nVent reserves the nVent right to change specifications without prior notice. n V' nt TECHNICAL SUPPORT: n�ent www.nVent.com CFS288_N 1 OF 2 ©2000-2021 nVent All Rights Reserved CADDY INSTRUCTION SHEET 100 & 100T HEAVY DUTY LOOP HANGER Global Part Nominal Rod Rod T e Static Load Number Pipe Size Size yp (Ibs) imiiii RIP1000200EG 2" 1000250EG 2-1/2" 1/2" 1000 1000300EG 3" 1000350EG 3-1/2" ANSI/MSS 1000400EG 4" Heavy Duty 1000500EG 5" 5/8 1100 1000600EG 6" 3/4" 1250 1000800EG 8" 7/8" This product provides pipe support for stationary non-insulated piping only. Model 100 conforms with federal specification 100 Series WW-H-171 (type 10), Manufacturers Standardization Society (MSS) SP-58 and SP-69 (type 10). MO Global Part Nominal Rod Static Load Number Pipe Size Size Rod Type (Ibs) 100T0200EG 2" 100T0250EG 2-1/2" ANSI/MSS 100T0300EG 3" 1/2' Heavy Duty 1250 100T0350EG 3-1/2" 100T0400EG 4" I I 100T Series 100T Series J, This product provides pipe support for stationary non-insulated piping only. Model 100T conforms with federal specification WW-H-171 (type 10), Manufacturers Standardization i`I Society (MSS) SP-58 and SP-69 (type 10). U fri 100T Series UL Listed to support trapeze assembly loads of 8" pipe sizes * �� Trapeze Pipe 4 115 or 100 Series 0 nVent,nVent CADDY,nVent ERICO Cadweld,nVent ERICO Critec,nVent ERICO,nVent ERIFLEX,and nVent LENTON are 1/ Ali*0/ owned by nVent or its global affiliates.All other trademarks are the property of their respective owners.nVent reserves the 1 right to change specifications without prior notice. nV/ent nVent TECH NICAnVLent.co SUPPORT:m www. CFS288_N 2 OF 2 ©2000-2021 nVent All Rights Reserved CADDY r0 A ffil NETZA® SIDEWINDER® FOR WOOD -Horizontal Application Application Product Features E. Not less than 2"nominal width •No pre drilling required. (1-1/2")up to 3-112"pipe;not less than 3"(2-1/2")nominal width 4"&5"pipe •Quick to install using the Sammy ... ..........�� .�-r u 4--7 Floor Joist Nut Driver with an 18V cordless Minimum 2-1/2"from bottom for drill/driver. branch lines.Minimum 3"from bot- tom for main lines.Exception:This •Saves time from traditional requirement shall not apply to 2"or methods. thicker nailing strips resting on top of steel beams. •Reduces installation costs. •Made in the U.S.A. • 1 I f Composite/Truss 1t Consult truss manufacturer for recommended Installation point. f *Pre-drilling may be required for Model SWG 25-380.Tool available cn page 11. Watch a video demonstrelion of www.itwbuildex.com) A royals Rod Part Model Screw Ultimate UL Test Box C - PP Size Number Descriptions Pullout(Ibs) Load(Ibs) Qty— Oty HORIZONTAL MOUNT 1/4" 8019957 SWG 200 114 x 2" 1725 (Fir) 25 125 1(s 3/8" . 8020957 SWG 10 1/4 x 1" 622(f°'rr)" 300 25 '. 125 <r. .Q. 3/8" 8021957 SWG 20 114 x 2" 1725 (Fir) 1050 25 125 — .Ql. 3/8" .8073925 SWG 20-SS... 114 x 2" 1725(Fir) ;:..850 25' 125, C:. 3/8"* 8022925 SWG 25-380 3/8 x 2-1/2" 2249 (Fir) 1500 25 125 #14 SW Red _ 3/8" 8023925 SWG 30 r>1/4 x 3° 1884(Rd25 ;125 Nut Driver Part#8114910 •May require pre-drilling;consult joist manufacturer. SAMMYS SWIVEL HEADTM FOR WOOD - Swivel Application se: Application Product Features 4 1,000 JOIST >kORT >e •Eliminates distortion of threaded rod. /CSTe •Accommodates up to 3'/:"x 12 pitch roof. •Allows 17°deflection from vertical. •Saves time from traditional methods. •Reduces installation costs. ,, p.m —' r •Made in the U.S.A. . HNIGER S MAX uuuESr Approvals Rod Part Model Screw Ultimate UL Test Load FM Test Min Box Case Size Number Descriptions Pullout(Ibs) (Ibs) Load(Ibs) Thickness Qty Dry i — .Q SWIVEL MOUNT t#14 Black .. ' 3/8" 8139957 SH-GST 20 1/4 x 2" 1257(Fir) 1050 1475 25 125 Part#81139 Nut Driver 10 — < 3/8` 8141957 SH-GST 30 1/4 x 3" 1720(fir) 1500 1475 25 125 1903 Dim.Lumber 1500 Q 318"* 8269957 SH-GST/CST 20 5/16 x 1-3/4" 1406 @ 45°off vertical 850 @ 45° 25 125 Dim.Lumber 903Dim.Lumber 1/2" 8303957 SH-GST/CST 2.0 5/16 x 1-3/4" 1408 @ 45°off vertical 25 125 Dim.Lumber "May require pre-drilling;consult joist manufacturer. • #14 SH Orange Nut Driver II, Part#8273910 • 5 To find a distributor near you,call 800-BUILDEX All Thread Rod Ferguson Alt 1 Size(in.x ft.) Black Galv SS 304 SS 316 1/2X10 BATRD10 GATRD10 1/2X12 BATRD12 GATRD12 SS4ATRD12 SS6ATRD12 1/2X6 BATRDU GATRDU SS4ATRDU SS6ATRDU 1/4X10 GATRB10 1/4X12 BATRB12 1/4X6 BATRBU GATRBU SS4ATRBU 1X10 GATRGIO All Thread Rod meets following specifications: 1X12 GATRG12 SS4ATRG12 ASTM A307 Domestic and Import All Thread Rod 1X6 BATRGU GATRGU SS4ATRGU ASTM A36 Domestic All Thread Rod only 3/4X10 BATRFI O GATRFIO 3/4X12 BATRF12 GATRF12 SS4ATRF12 SS6ATRF12 ATSM B 633 Domestic and Import Clear 3/4X6 BATRFU GATRFU SS4ATRFU Zinc Plated/Yellow Zinc Plated 3/8X10 BATRC10 GATRC10 SS4ATRC10 ASTM A 153 Domestic and Import Hot 3/8X12 BATRCI2 GATRCI2 SS4ATRC12 Dipped Galvanized ASTM A193-08B Import Stainless Steel T-304 3/8x12 SS6ATRC12 ASTM A193-B8 Domestic Stainless Steel T-304 3/8X3 GATRCM 3/8X6 BATRCU GATRCU SS4ATRCU ASTM A193 B8M Domestic Stainless Steel T-316 3/8X6 SS6ATRCU 5/8X10 BATRE10 GATRE10 5/8X12 BATRE12 GATRE12 SS4ATRE12 5/8X3 SS4ATREM 5/8X6 BATREU GATREU SS4ATREU 7/8X10 BATR7810 GATR7810 7/8X12 BATR7812 GATR7812 SS4ATR7812 SS6ATR7812 7/8X3 SS4ATR78M 7/8X6 BATR78U GATR78U SS4ATR78U Distributed Exclusively by Ferguson and Wolseley Canada ©2014 Ferguson Enterprises,Inc. All Rights Reserved 20348 04/14