Loading...
Report (2) 13vP2o22 — Dot—l"i Tualatin Valley Water District 3 s St...) �L N�N ST Delivering the Best Water Service Value October 25, 2021 REACH Community Development Attn: Erik Pattinson 4150 S Moody Avenue Portland, OR 97239 Subject: Statement of Service Availability Dear Mr. Pattinson, Tualatin Valley Water District has adequate capacity to provide service to Tax Lots 2900, 3001, and 3100 (assessor tax map 1S136DD)from the 12"waterlines on SW Clinton St and SW 68th Pkwy, and the 8"waterline on SW 69th Ave. The proposed use will make the necessary connections and/or extensions of water mains, as required,to serve the subject property and will be shown on plans submitted for approval prior to connection to the system. Contact the Tualatin Valley Water District for requirements regarding submittal of plans for review and approval and for review fees or any questions you may have. Sincerely, Digitally signed by Sarah Afton o DN:C=US, E=sarah.atton@Nwd.org, O= WD,Alton eedng, Dae:2021arah Afton Date:xort.to.zs ta:os:n-oroo' Sarah Alton, PE Engineering Associate Sarah.alton@tvwd.org 971-327-6304 18505W 170th Avenue • Beaverton,Oregon 97003 • Phone:503-642-1511 • Fax:503-649-2733 • www.tvwd.org October 20, 2021 Tigard, OR, 97223 Subject: Proposed construction site at 11800 SW 69th Ave., Tigard, Oregon Dear REACH DEVELOPMENT/Dartmouth Crossing Apartments: Thank you for inquiring about electrical services provided through Portland General Electric. Your proposed project located in Tigard, Oregon is within PGE's service territory. PGE has enough electrical capacity to serve your anticipated load. However, in all likelihood, additional infrastructure and electrical equipment will need to be installed to serve this anticipated load. This letter does not address any issues concerned with easements or right-of-ways. The owner/developer is responsible for all costs associated with providing electric service to a new project, including the expenses for realigning existing electric facilities. However, PGE currently has a line extension allowance (LEA) that may help offset some of the costs of providing electrical service. We calculate the LEA for your project based on an estimate of the yearly incremental kWh consumption. This LEA is subject to change. Please note that the LEA does not apply to certain project expenses involving underground service. The owner/developer is always responsible for the cost of all necessary excavation, trenching, conduit, vaults, submersible transformers, pads and permits. Expenses for providing electric service to a project can be considerable. In order to provide a good cost estimate, PGE must receive your detailed plans and load estimates. When you have this information, please call (503) 323-6700, and a Service and Design Consultant will be assigned to your project and make contact with you. Sincerely, Hap English Portland General Electric cc: Click here to enter text. p* R * 1 * D * E DISPOSAL COMPANY P.O. Box 820 Sherwood, OR 97140 Phone: (503) 625-6177 Fax: (503) 625-6179 October 15, 2021 Christian Cutul Bora 720 SW Washington, Suite 800 Portland, OR 97205 Re: Dartmouth Crossing We have reviewed the site plan for the above-mentioned project. The site plan shows one trash room 14'6" x 22'6"that will hold front load trash and recycling containers (provided by Pride Disposal). This room is for trash and recycling only, no other material will be stored there. Our driver will be responsible for moving the trash and recycling containers in and out of the trash room on collection days provided the electric pallet jack is available for our driver to access. The site will also have an electronic key pad, which you will provide the code to Pride to allow for access to the containers via the roll up door on collection days. There is a 8' wide motorized coiling door that the drivers will use to move containers in and out of the trash room. If there are any modifications to this site plan, Pride will need be made aware of those changes and sign off on them before the modifications can be made. If you have any questions, feel free to contact me. Sincerely, Kristen Tabscott Pride Disposal Co. (503) 625-6177 ® www.tvfr.com Tualatin Valley Fire & Rescue October 5, 2021 Christian Cutul/Bora Architecture, Associate Planner/ City of Tigard 13125 SW Hall Blvd Tigard, Oregon 97223 Re: 11770 SW 69TH, 11800 SW 69th, 6835 SW Clinton St Tualatin Valley Fire and Rescue has the equipment and staffing to provide Fire protection and emergency services to the address of 6835 SW Clinton St. Tigard Oregon 97223, encompassing the neighboring addresses noted above. If you have questions or need further clarification, please feel free to contact me at 503-259-1504. Sincerely, 2•040.1. WO John Wolff Deputy Fire Marshal II John.wolff@tvfr.com Cc: A full copy of the New Construction Fire Code Applications Guide for Residential Development is available at http://www.tvfr.com/DocumentCenter/View/1438 Command and Business Operations Center and South Operating Center Training Center North Operating Center 8445 SW Elligsen Road 12400 SW Tonquin Road 11945 SW 70th Avenue Wilsonville,Oregon Sherwood,Oregon Tigard,Oregon 97223-9196 97070-9641 97140-9734 503-649-8577 503-259-1500 503-259-1600 Agnes Lindor From: Agnes Lindor Sent: Wednesday, February 22, 2023 11:50 AM To: Alex Aleman Cc: Christian Cutul; Brady Bullinger; Hope Pollard Subject: RE: Dartmouth Crossing BUP2022-00177 Thanks Alex. This permit is approved but cannot be released until the PFI permit issued. Please also send me your approved SDC exemption once approved so that I can put it with the permit records.Thanks again! Agnes Lindor I Senior Planner City of Tigard I Community Development 13125 SW Hall Boulevard Tigard, Oregon 97223 Phone: 503.718.2429 Email:AgnesL@tgard-or.gov From:Alex Aleman<AAleman@reachcdc.org> Sent:Wednesday, February 22, 2023 10:55 AM To:Agnes Lindor<agnesl@tgard-or.gov> Cc: Christian Cutul <cutul@bora.co> Subject: RE: Dartmouth Crossing Hey Agnes, See below for the answers to your questions, Let me know if you need anything else, Thanks, Alex Alex Aleman Housing Development Project Manager I he/him/his Email:AAleman@reachcdc.org I Direct:323-547-9634 I Fax:503-236-3429 Main Office:4150 S Moody Ave. I Portland,OR 97239 REACH In 0 112 r rid Community Development Everyone deserves a place to call home. 1 From:Agnes Lindor<agnesl@tgard-or.gov> Sent:Wednesday, February 22, 2023 10:45 AM To:Alex Aleman<AAleman@reachcdc.org> Cc: Christian Cutul<cutul@bora.co> Subject: Dartmouth Crossing Hi Alex/Christian- I just wanted to confirm the following: 1. There were 4 existing homes on this site that were demolished, correct? I do not think there were any homes on the property, my understanding is that this has been a vacant property for quite some time, Currently it is vacant and Reach has not done any demolition work since owning the property in 2019. 2. The proposal only includes housing (with support services), no retail/office that would make this mixed-use, correct? Correct,this will only be 100%affordable housing with supportive services for the residents,our community room will be for our residents, Thanks! Agnes Lindor I Senior Planner City of Tigard I Community Development 13125 SW Hall Boulevard Tigard, Oregon 97223 Phone: 503.718.2429 Email:L correct? DISCLAIMER: E-mails sent or received by City of Tigard employees are subject to public record laws. If requested, e-mail may be disclosed to another party unless exempt from disclosure under Oregon Public Records Law. E-mails are retained by the City of Tigard in compliance with the Oregon Administrative Rules"City General Records Retention Schedule." 2 , ,_ ,BoRA MEMORANDUM Date Project Name Project Number June 6, 2022 Dartmouth Crossing 30095 6835 SW Clinton Street Tigard, OR 97223 To From Subject Gary Pagenstecher Christian Cutul Project Compliance Report Project Planner,City of Tigard 13125 SW Hall Blvd Tigard OR 97223 garyo@tgard-or.gov Copy Alex Aleman, REACH CDC This memo identifies information required by the TMU Zone Development Review Worksheet:Site Details, Project Details,and the Project Compliance Report. Site Details • Tax lot numbers: 11800 SW 69th Ave(tax lot 3100-7), 11770 SW 69th (tax lots 2900-5&2900- 6), and 6835 SW Clinton St(tax lot 3001-8);consolidation application LLC2021-00007 was approved and recorded. See G101 for vicinity/site map and V102,V103 for survey map. • Site size and dimensions:Total site area is 37,350 SF excluding right of way dedications. • Names and Locations of existing streets:The site has frontage on three streets (SW 68th Ave, SW 69th Ave,SW Clinton Street),and negotiates 10 to 18 feet of grade change between SW 68th and SW 69th Avenues. • Location of future streets, paths,or trails: N/A • Location of natural resources: N/A Project Details • Proposed and existing uses to remain:The site was cleared by the prior owner, has no structures or trees,and lacks public right-of-way improvements. • Proposed and existing site improvements to remain:The site will be graded for development work. • Proposed and existing buildings to remain: No existing uses. The project proposal is for a 4- story building with 85 units of affordable housing with 4 off-street parking spaces. 720 SW Washington,Suite 800 Portland,Oregon 97205 503 226 1575 www.bora.co BORA • Proposed demolition or modification of any existing buildings or site improvements:There are no existing buildings or site improvements. The public right-of-way will be built out and site landscape improvements will cover all remaining surfaces. Project Compliance Report I. Site and Building Design Standards (Sections 18.660.070& 18.660.080) 1. Building Location:See Site Plan on G100. 2. Utilities and Services:Above grade transformer is screened. See Site Plan on G100 and Landscape drawings. 3. Off-street Vehicle Parking: (4)on-site parking spots are provided. They are 9'x18.5', uncovered, and screened by the transformer screen. The parking area is paved and has a turnaround zone. Parking is 34'-8"from the property line. In prior discussions about potential adjustments, Gary Pagenstecher did not feel that the parking distance warranted an adjustment for being<35'. See landscape and civil drawings for documentation of parking. 4. Off-street Vehicle Parking Landscaping: N/A,<10 spaces. 5. Public Bicycle Parking:The building has 498.5'of building frontage along street property lines, requiring (498.5'/30') = 16.6 bicycle parking spaces. (10) bicycle staple racks are located in the ROW, accommodating (20) bicycle spaces. A ROW encroachment permit will be requested. 6. Walls and Fences: No retaining walls or fences above grade are being provided. At the southeast corner of the building,there is a below-grade retaining wall with a 42"guard/screen for fall protection, per building code. 7. Street Screens:The above-grade transformer is surrounded by an 8'tall screen. The length (12.5') is driven by the size of the transformer and PGE-required clearances. On-site parking is also screened by the transformer enclosure. 8. Driveways: (1) 20'wide driveway is provided. A sight distance memo has been submitted with the PFI application. 9. District Trees: N/A. There are no trees on site or in the ROW. 10. Building Height: Proposed building is 4 stories. See drawing sheets A201,A202,A301,and A302 for elevations and sections with floor level elevations noted. An adjustment for first story height was approved in ADJ 2021-00033, as a portion of the first floor has 10' height due to site topography. 11. Building Entries: Building entries are shown on G100 and have weather protection.The main building entry is>35'from the street property line due to plaza design;adjustments were approved in ADJ2021-00033 for the main building entry distance from the street property line, and for the building length along SW 68th Avenue without an entry. 12. Building Projections: N/A. There are no projections into the ROW. 13. Building Windows: Clear glass windows are provided. See building elevations on drawing sheets A201 and A202. Adjustments for first floor window area were approved in ADJ2021- 00033. II. Transportation Facility Standards(Section 18.660.090) 1. Project Triggers ROW dedication and Street Frontage Improvements:See active PFI permit application for ROW improvements, PF12022-00169. ROW dedication has been processed with the lot consolidation, per LLA2021-00007. See also Record of Survey,drawing sheet V103. III. Minimum Public Facility Standards (Section 18.660.040.B.2.c) 1. Site has frontage on a public street. 2. A minimum of 24'of pavement and horizontal clearance on a public street along each frontage where access is taken:exists. See PFI application package. 3. Adequate public utilities&stormwater management facilities:See PFI application package. garyp@tigard-or.gov page 2 of 3 -- - 8ORA 4. Encroachments: Public bicycle parking is proposed in ROW. An encroachment permit will be submitted. 5. Adjustments:See ADJ2021-00033 notice of decision,02/14/2022. END OF MEMO garyp@tigard-or.gov page 3 of 3