MEC2023-00576 ME,C2Oz?,- cos-i QFFICE COPu WEST COAST AIR PRODUCTS INC. SUBMITTAL 'I/ RECEIVED SUBMITTAL DATMCE COPY JUN 2 0 2023 for Electric Heaters CITY OF TIGARD BUILDING DIVISION Project: Dartmouth Crossing Date: 6/9/2023 Revision No.: Architect: BORA Architects Submitted for Approval Engineer: Hunter-Davisson Submitted by Sharon Watt Contractor: Hunter-Davisson WCAP Job: 23048 1. The product description for specification conformance is shown below. For dimensions and quantities,see attached data. 2. It is the contractor's responsibility to verify all sizes prior to ordering equipment.Sizes submitted are based on contract documents and must be verified against field conditions. 3. Unless otherwise noted,this data is submitted for approval by the authorized party. Orders released for production prior to receipt of such approval are the responsibility of the customer for conformance to specification and dimensional requirements. Changes made to orders placed without approval maybe subject to additional costs. Tag Qty Description Nominal Reference ECH-1 260 Radiant Systems Cove Heaters See attached Radiant Systems thru Comfort Cove'"heater w/wall bracket;pure white finish. Submittal ECH-6 Accessories(shipped loose): IOM Honeywell wall thermostat, model T4016 Warranty EWH-1 8 INDEECO Wall Heater,WLI Series See attached INDEECO Submittal Thru Recessed heater with integral adjustable thermostat; IOM EWH-8 white finish. Warranty Total 268 Tel: (503)786-1412 Oregon WBE#1478 Fax: (503)786-1413 8800 SE Sunnyside Road,Suite 253-S Clackamas,OR 97015 III I C' C-Series C) a D �, „ Comfort Cove® (A 1006 W HWY 20 PO•Box 47, Valentine, NE 69201 o Heater m Visit: www.radiantsystemsinc.com for more information SUBMITTAL m SHEET ODD "= o 3 Project: Dartmouth Crossing 0 P- Date: 6/9/2023 O Architect: BORA Architects CD Engineer: Hunter-Davisson = m Contractor: Hunter-Davisson ID r-r CD Submitted by: West Coast Air Products, Inc. (Sharon Watt) WCAP Job No. 23048 Approved by: HEATERS TAG QTY. CAT. NO. SIZE VOLTS WATTS FINISH ECH-1 159 C4512 34" 120/1PH 450 PURE WHITE ECH-2 11 C6012 47" 120/1PH 600 PURE WHITE ECH-3 2 C7512 59" 120/1PH 750 PURE WHITE ECH-4 67 C10512 83" 120/1PH 1050 PURE WHITE ECH-5 18 C12012 88" 120/1PH 1200 PURE WHITE ECH-6 3 C15008 94" 208/1PH 1500 PURE WHITE Controls & Accessories TAG QTY. CAT. NO. DESCRIPTION ECH-ALL 260 T401B THERMOSTAT, 22AMP, DPST 120/20/240 ©All Rights Reserved.• 1006 West Hwy 20•PO Box 47•Valentine,Nebraska 69201 •800-314-9303 I Heat At Light Speed® N1006 W HWY 20 PO•Box 47, Valentine, NE 69201 Visit: www.radiantsystemsinc.com for more informationI g N ARCHITECTURAL AND ENGINEERING SPECIFICATIONS* > Furnish and install where indicated,Type C-Series Comfort Cove®heaters as manufactured by Radiant Systems Inc., U Valentine, NE. Heaters shall be cULus listed.The heater shall be designed to provide radiant and convection heating in the area to be heated. CONSTRUCTION: `i— Front Panel: Shall be extruded aluminum, coated with a"flat finish"to produce maximum emissivity. Off-white,Almond,Walnut, Sandalwood and Pure White high temperature finishes are to be specified. 0 U Back Shield Reflector: Shall be formed of minimum 18 gauge reflective galvanized steel and shall cover entire back portion of the radiant heat emitting front panel. Back shield reflector shall also contain a wire raceway and a ventilated U) electrical junction box such to provide electrical hook up on either end.Ventilation openings are to be integral to back shield LLI reflector. wElectrical: Internal wiring shall be 12 Gauge,125 Degree Celsius rated UL 3173 XLPE. Cl') Heating Element: Shall be aluminum sheathed and shall consist of 80/20 nickel-chrome resistance wire and carry a ten (10) year factory warranty. U Installation: Mounting brackets and back shield reflector shall be of single piece construction permitting efficient installation. SELECTION CHART CEILING Catalog Number Voltage Wattage Amperes Length 2-1/2"MIN.(DRY WALL CEILING) C-4512 120 450 3.8 34" 4-1/2"MIN.(LAY IN,VINYL,LATH& ) C-4508208450 2.234" PLASTER OR PLASTIC MOLDING 1111 C-4524 24 24040 450 L9 34" C-6012 120 600 2.9 47" ' j C-6008 208 600 2.5 47" C-6024 240 600 2.5 47" C-7512 120 750 6.2 ss'. 1"MIN.BETWEEN BOTTOM C-7508 208 750 3.6 59" OF HEATER AND ANY FABIRC C-7524 240 750 3.1 59" n h OI C-9012 120 900 7.6 71" l�u C-9008 208 900 4.3 71" D C-9024 240 900 3.8 71" r r C-10512 120 1050 8.8 83" C-10508 208 1050 5.0 83" 6'MIN Cl C-10524 240 1050 4.4 83" C CLEARANCE 73 C-12012 120 1200 10.0 94" TO FLOOR C-12008 209 1200 5.8 94" C-12024 240 1200 5.0 94" b!ii C-15008 208 1500 7.2 106 1/4" C-15024 240 1500 6.3 106 1/4" C-18008 208 1800 8.6 118 1/4" C-18024 240 1800 7.5 118 1/4" C-20008 208 2000 9.6 132" C-20024 240 2000 8.3 132" FLOOR ' Radiant Systems Inc.reserves the right to change specifications without prior notice. REAR VIEW CEILING TO CENTER OF KNOCK OUT 4.3/4"MIN.(DRY WALL CEILING) CEILING —63/4"MIN.(LAY IN.VINYL.LATH& /11/////////////////////////1/!1/1///////////////////////////////////////////////, _ PLASTER OR PLASTIC MOLDING ▪O ,� ..ox 4,. 1.114" 34"TO 132" TOP VIEW 2'7B" .- 2000 - - 0000o0o0omo0o0o0000000 �• � o00.J..r.�000000000 _ _ _ _ 000000 X //1111/1/L!!2/11/1/////1111111/11///111/1111/1/11/1///1111/1/1/1.6.7., /1///1/////, + f WALL 718" Radiant Systems P/N T401B Honeywell T41 OA,B Electric Heat Thermostats PRODUCT DATA FEATURES • Energy efficient and economical. • UL listed up to 5 kW at 277 Vac. • ncludes long-lasting Micro Switch"' mechanism. • Rugged,plastic mounting base one-piece cover. • Contemporary white finish complements any decor. • Replaces virtually any wall-mounted electric heating i ea•so• thermostat. i i J Models: GENERAL T410A Electric Heating Thermostat:Spst switching heating circuit makes on temperahirP fall The T410A,B Electric Heat Thermostats provide line voltage T410B Electric Heating Thermostat:Dpst switching; makes control of electric heating equipment. Snap-action switch double line break with setting dial at OFF position;heating makes heating circuit on temperature fall. circuit makes on temperature fall. Electrical Ratings (Noninductive Resistive Rating): SPECIFICATIONS 22A at 120/208/240 Vac; 19A at 277 Vac. Wiring Connections: IMPORTANT 6 in.(150 mm)copper leadwires,suitable for connecting to The Specifications given in this publication do not aluminum wiring if approved CO/ALR solderiess wire con- include normal manufacturing tolerances. Therefore, nectors are used. this unit may not exactly match the listed specifica- tions.Also, this product is tested and calibrated Sensing Element: under closely controlled conditions, and some minor Bimetal. differences in performance can be expected if those conditions are changed. For exact engineering spec- Setpoint Adjustment: ifications, contact your Honeywell sales representa- Setting dial on the face of the thermostat. Live. Temperature Range: 40°to 80°F(5°to 25°C). ®U.S.Registered Trademark 111 11 II I 11 II III Copyright®2001 Honeywell• All Rights Reserved 68-0145EF T410A,8 ELECTRIC HEAT THERMOSTATS Differential: 3°F(2°C), nonadjustable. W' MERCURY NOTICE Switching: If this control is replacing a control that contains Micro Switch snap-acting switch. mercury in a sealed tube,do not place your old control in the trash.Dispose of properly. Mounting: Mounts directly on NEMA standard 2 x 4 in.vertical outlet box, Contact your local waste management authority for or 4 x 4 in, outlet box if used with ring adapter(ordered instructions regarding recycling and the proper separately),using 6-32 Robertson slotted screws. disposal of an old control. Dimensions: See Fig.1. INSTALLATION Approvals: Underwriters Laboratories Inc. Listed: File No. E47434, When Installing this Product... Guide No.XAPX. Canadian Standards Association Certified: File No. LR1322. 1. Read these instructions carefully. Failure to follow these instructions could damage the product or cause a Accessory: hazardous condition. 272804A Range Stop and Locking Cover Assembly:Includes 2. Check the ratings on the product to make sure the locking cover screws,Tinnerman clips,wrench and range product is suitable for your application. stops—two plastic pins to insert inside cover for field-selec- 3. Installer must be a trained, experienced service tion of minimum and maximum temperature settings. technician, 4. After installation is complete,check out product operation as provided in these instructions. FRONT VIEW SIDE VIEW r-1-1r2(38) a„-4- 5/8(14) A WARNING (19) HIGH VOLTAGE CONTROL. u U V v v ` ELECTRICAL SHOCK HAZARD. Honeywell 1 Follow local codes and ordinances when installing this thermostat. Improper handling can cause serious no. �'80'To 2-118 injury or death. • av2 (115) 3-5116 °F 1 1 (5•3) A CAUTION 1 1. Disconnect power supply to prevent electrical shock n 0 o n n or equipment damage. 1-3'8 2. When connecting with aluminum conductors,use .4'-2-3/4(70)-141 I.7.118(29)4- (35) COIALR solderless wire connectors to avoid fire M5P2A hazard. 3. To avoid damaging the sensing element,do not Fig. 1. T410 approximate dimensions in In. (mm). remove thermostat cover until wiring is complete. ORDERING INFORMATION When purchasing replacement and modernization products from your TRADELINE®wholesaler or distributor, refer to the TRADELINE®Catalog or price sheets for complete ordering number. If you have additional questions, need further information,or would like to comment on our products or services, please write: 1. Your local Home and Building Control Sales Office(check white pages of your phone directory). 2. Home and Building Control Customer Relations Honeywell, 1885 Douglas Drive North Minneapolis,Minnesota 55422-4386 In Canada—Honeywell Limited/Honeywell Limitee, 35 Dynamic Drive, Scarborough, Ontario MIV 4Z9. International Sales and Service Offices in all principal cities of the world.Manufacturing in Australia, Canada, Finland. France, Germany,Japan, Mexico, Netherlands, Spain,Taiwan,United Kingdom,U.S.A. 68-0145EF 2 T410A,B ELECTRIC HEAT THERMOSTATS Location Install a vertical outlet box,which is used to mount the T410A thermostat, about 5 ft(1.5 m)above the floor in art area with good air circulation at room temperature. Do not install the thermostat where it may be affected by: —drafts or dead spots behind doors, in corners or under cabinets. —hot air from convectors. —radiant heat from sun or appliances. SOLDERLESS —concealed pipes and chimneys. CONNECTORS + ELECTRIC —unheated(uncooled)areas such as an outside wall behind HEATER the thermostat. A 11 (HOT) • LL Wiring and Mounting L2 ,L POWER SUPPLY.PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. ! CAUTION © USE SPECIAL SERVICE COIALR SOLDERLESS CONNECTORS WHEN CONNECTING ALUMINUM CONDUCTORS OR A FIRE HAZARD MAY RESULT. 1. To avoid damaging the sensing element,handle the thermostat with care. © USE A SEPARATE LIMIT CONTROL IN THE HEATING APPLIANCE. 2. Use a separate limit control in the heating 4Q BREAKS AND REMAKES BELOW-31 F(-35 C);NORMALLY appliance. THERMAL ACTIVATED_BREAKS ON TEMPERATURE RISE', 3. To prevent damage to dial stop when mounting the MAKES ON TEMPERATURE FALL use„e thermostat,turn the temperature setting dial until the setpoint indicator is at the 12 o'clock position. Fig.2. Typical wiring connections for T410A. Replacement Applications 1. Disconnect power to the thermostat to prevent electrical T410B ` RED shock or equipment damage.All wiring must comply WIRE with local electrical codes and ordinances. ® 2. Remove the old thermostat from the wall,taking care Q 5 not to damage the wiring insulation. 3. Check the old wire insulation for cracks,nicks or fraying. If necessary,apply approved electrical tape to insulate old wires or replace with new wires. 12 4. Do not remove the T410 Thermostat Cover. Using wire connectors approved for No. 12 wires, make line volt- age connections directly to the leadwires on the thermo- stat. See Figs.2 and 3 for typical wiring connections. ELECTRIC 5. Prebend and push solid wires into the outlet box. f HEATER 6. Remove thermostat cover by grasping the top and bot- Q torn ]--cs\ cover edge and pulling it outward away from the thermostat base. L2 SOLDERLESS O Qa 7. Turnthe temperature setting dial so the setpoint indica- Li Q CONNECTORS tor is at the 12 o'clock position to prevent damaging the (HOT) dial stop. A POWER SUPPLY.PROVIDE DISCONNECT MEANS AND 8. Mount the thermostat on the outlet box.Tighten the two OVERLOAD PROTECTION AS REQUIRED. mounting screws(included)to secure the thermostat, © USE SPECIAL SERVICE COfALR SOLDERLESS CONNECTORS taking care to avoid excessive pressure on the setting WHEN CONNECTING ALUMINUM CONDUCTORS OR A FIRE dial.See Fig.4. HAZARD MAY RESULT. • BREAKS AT POSITIVE OFF AND REMAKES UNDER-31 F(-35 C), NORMALLY THERMALLY ACTIVATED. BREAKS ON TEMPERATURE RISE; MAKES ON TEMPERATURE FALL. A USE A SEPARATE LIMIT CONTROL IN THE HEATING APPLIANCE © BREAKS AT POSITIVE OFF ONLY;NOT THERMALLY ACTIVATED. 5k DO NOT CONNECT GROUNDED CONDUCTOR(NEUTRAL)ON 120 OR 227V CIRCUITS.INSULATE AND TAPE OR CUT OFF RED WIRES IF UNUSED. M5e1213 Fig.3.Typical wiring connections for T410B. 3 68-0145EF T410A,B ELECTRIC HEAT THERMOSTATS SETTINGS AND CHECKOUT _`WALL Setting The thermostat temperature setting can be adjusted by turning the setting dial clockwise or counterclockwise to the O THERMOSTAT desired setting.See Fig.5.To determine appropriate setting, �O f BASE allow the thermostat to operate for several hours. 0 I( ' I Checkout IMPORTANT OUTLET f � fr -� Make sure all wiring connections are tight before pro- eox� ceeding with Checkout. Check out thermostat operation as follows: 1. Turn the setting dial fully clockwise; heating circuit \_ makes and electric heater starts. � 2. Turn the setting dial fully counterclockwise;the heating MOUNTING circuit breaks and the heater starts to cool. SCREWS(2) WSD3 Fig.4.Mounting thermostat on outlet box. 1p New Applications .. -- 1. Dequip ant power .All ly wiring preventmustelectrwcal shock or ♦� equipmenc damage.orl wiring must comply with local \` electrical codes and ordinances. � ff 2. Run line voltage wiring to the thermostat location. �y0 3. Do not remove the T410 Thermostat Cover. Using wire g1 connectors approved for No. 12 wires,make line volt- TURN age connections directly to the leadwires on the thereto- TURN SETTING DIAL stet. See Figs.2 and 3 forCLOCKWISE OR COUNTER. g typical wiring connections. CLOCKWISE TO ADJUST 4. Prebend and push solid wires into the outlet box. trO° • IO'Bp TEMPERATURE SETTING 5. Remove the thermostat cover by grasping the top and bottom cover edge and pulling it outward away from thethermostat base.6. Turn the temperature setting dial so the setpoint indica- °for is at the 12 o'clock position to prevent damaging thedial stop. 7. Mount the thermostat on the outlet box.Tighten the two mounting screws(included)to secure the thermostat, taking care to avoid excessive pressure on the setting dial.See Fig.4. 4 4 4 415904 Fig.5.Adjusting temperature setpoint. Honeywell Automation and Control Solutions Honeywell Honeywell Limited-Honeywell Limitee 1985 Douglas Drive North 35 Dynamic Drive Golden Valley.MN 55422 Scarborough.Ontario ACV 4Z9 88-0145EF G.H. 12-01 Printed in U.S.A.on recycled ., paper containing at least 10% www.honeywell.comiyourhome post-consumer paper fibers. COMFORT-COVE Model C-Series Warm Your Floor and More TM SAVE THESE INSTRUCTIONS Thank you for choosing c (Dus Comfort-Cove®! FILE # USA: KKWS.E99303 ?DF " CANADA: KKWS7.E99303 1111 American Made Product /i IMPORTANT INSTRUCTIONS Radiant Systems, Inc., proudly manufacturers SAVE THESE INSTRUCTIONS Comfort-Cove® in the Heartland of America; Read Carefully - These instructions are written to help you prevent difficulties that might arise during installation in Valentine, Nebraska, USA. Our Comfort- of heaters. Studying the instructions first may save you considerable time and money later. Observe the Cove® heaters are even compliant with the Buy following procedures, and cut your mounting time to a minimum. American Act. REDUCE RISK OF ELECTRIC SHOCK: Then &Now 1. Read all instructions before installing or using this heater We started like most American businesses, by 2. This heater is hot when in use. To avoid burns do not let bare skin touch hot surfaces. Keep an individual with an idea and determination. combustible materials such as curtains or drapes at least 1 inch away from the bottom of the heater and Our story began back in 1985 with founder and keep at least 1 inch from both sides 3. Do not operate any heater if it malfunctions. owner, Kirk Sharp. Production began in his Disconnect power at service panel and have heater inspected by an electrician before reusing. basement and is now operating out of a 30,000- 4. Do not use outdoors 5. To disconnect heater, turn controls to off, and turn square foot factory. The Comfort-Cove® off power to heater circuit at main disconnect panel. 6. Do not insert or allow foreign objects to enter any heater has constantly been innovated, ventilation or exhaust opening as this may cause an electric shock, fire, or damage to the heater engineered, and improved for optimum 7. To disconnect heater, turn controls to off, and turn performance for the last 30 ears. off power to heater circuit at main disconnect panel y 8. Not approved for use in hazardous storage locations 9. This heater is not approved for use in corrosive From the Owner atmospheres 10. Use this heater only as described in this manual. Any other use not recommended by the Thank you for choosing Comfort-Cove® for manufacturer may cause fire, electric shock, or injury to persons your heating needs, we take pride in our work MAINTENANCE SCHEDULE: and would like to thank you for supporting a 1. No maintenance required local business such as ours, we wouldn't be 2. If dusting the top of heater is desired,disconnect at circuit here withoutyou. breaker and heating element is cool,using a dry rag or `,,✓ duster and swipe the entire top of heater 49(C R. Kirk Sharp / www.ComfortCove.com 1-800-314-9303 8AM — 5PM CST ' Comfort-Cove® Mounting & Clearances 1. Locate a wall stud for each bracket such that when the _ heater is attached to the brackets they are spaced _ approximately 12"from heater end. CEILING , v/ BE gHIELD ke 2. Attach brackets to wall studs with wood screws ' ` provided, use template provided to mark screw locations / BRACKET WALL depending upon type of ceiling. (Figure 1) ` TILT AND LOCK 3. Attach back shield to brackets by tilting Back Shield �' back and allowing Back Shield slot to fall onto bracket �� hook,then simply bring Back Shield forward locking into •/ - I� place. 4. Hang Front Panel on Back Shield and complete wiring r as directed. (Note: if left and or right clearance is ' restricted attach end caps to front panel before hanging) 5. Complete wiring as shown on Page 3. Can be wired from either end. CEILING 6. Secure Front Panel to Back Shield using supplied 2-1/2"MIN.(DRY WALL,WOOD) 1l painted screws and Teflon washers. 4-1/2"MIN.(LAY IN,VINYL, LATH& PLASTER OR PLASTIC MOLDING) 7. Attach End Caps(Teflon washer not needed). 1°1 8. Loosen the two outermost painted screws holding 1"MIN.BETWEEN BOTTOM the painted Front Panel in place about one revolution, OF HEATER AND ANY FABIRC (this is to allow for thermal expansion). con 9. When Comfort-Cove®is first energized, an initial break- 1 [f D in fragrance may be noticed—this is normal. (Do not r touch while energized) 6'MIN f7 c A CAUTION 4k CLEARANCE 73 TO FLOOR D 1. Do not recess Comfort-Cove® heater U 2. Never install heater without supplied wall brackets 3. Heater should not be blocked in any manner 4. Do not use plastic conduits for direct connection to Comfort-Cove® FLOOR 5. DO NOT PAINT HEATER IN ANY MANNER REAR VIEW CEILING TO CENTER OF KNOCK OUT 4-3/4"MIN.(DRY WALL,WOOD) CEILING —6-3/4"MIN.(LAY IN,VINYL, LATH& ////////44/ ///////// ////// / .44///,/// //// //// //4/.. /.4 PLASTER OR PLASTIC MOLDING) p p 4 - 1-114" 34" TO 132" Figure #1 TOP VIEW 2-7/8" o0000=OOOO�o=ocmooao�==�0,0000oo=00 J' t o0000000000000e00000�000000�e5eeoeor� �e WALL —7/8" Page I 2 Comfort-Cove® Installation & Wiring itr Mounting Bracket �p� '' End Cap Back Shield ��i o Front Panel SINGLE COMFORT-COVE CONNECTION ® moo _off OO = �u FRONT RADIANT PANEL.00 ' 1 OOC 7 O, 1 • GROUND LOAD ELEMENT ELEMENT 120 V • eEa Avvws • wr,re 208 V OR • °_ECa V V V v • °LACE POWER 240 V SUPPLY POWER • s`Acn SUPPLY • BE, 1-40 GROUND r--• GROUND MULTIPLE COMFORT-COVE CONNECTION 1. Allow 1" clearance between heaters 2. Do not exceed 16 amperes per circuit 3. Do not exceed thermostat ratings 4. Comfort-Coves must be wired in Parallel POWER ELEMENT ELEMENT ELEMENT SUPPLY • GROUND Page I 3 Commonly Asked Questions Q. How do I clean the front panel if it gets a smudge? Q.What is the best mounting location, an interior,exterior wall A.Turn off power to the heater at the circuit breaker and the or above a window? heating element is cool. Do not use chemicals of any kind. A.You can mount on any wall,we simply recommend mounting Simply take a clean, damp white cotton washcloth and wipe where it is most convenient to wire and or appealing to the user. the surface clean. Q.Where is the most efficient place to mount the thermostat? Q. Can I paint the heater? A. Temperature controls are most accurate on interior walls. Mount A. Never paint the heater with aftermarket paint. Contact where it is convenient to wire and for the user to operate. Do not factory to obtain approved coating materials. mount directly above dimmer switches. Q.Which costs less to operate 120 volt or 240 volt? A. Electricity is billed by kilowatt-hours, voltage makes no difference. Comfort-Cove Replacement Parts & Specifications From high quality, locally sourced raw materials, Comfort- Cove®is specifically engineered for fast installation with easily Model q Wattage Voltage Amperes Length Weight replaceable parts. C-4512 120 3.8 34" C-4508 450 208 2.2 34" 6 lbs For replacement parts, simply refer to your Comfort-Cove® C-4524 240 1.9 34" specifications Nameplate located on the top of the Back Shield C-6012 120 5.0 47" for heater information. Have model number ready when C-6008 600 208 2.9 47" 8 lbs contacting factory for replacement parts. See below for C-6024 240 _ 2.5 47" example. C-7512 120 6.2 59" C-7508 750 208 3.6 59" 10 lbs C-7524 240 3.1 59" C-9012 120 7.6 71" UP*4.°1° C-9008 900 208 4.3 71" 12 lbs -I.- C-9024 240 3.8 - 71" C-10512 120 5.0 83" C-10508 1050 208 5.0 83" 13 lbs C-10524 240 4.4 83" C-12012 120 10.0 94" EXAMPLE NAMEPLATE C-12008 1200 208 5.8 94" 15 lbs C-12024 240 _ 5.0 94" COMFORT COVE C-15008 208 7.2 106 1/4" RADIANT SYSTEMS INC,VALENTINE,NE 69201 1500 18 lbs fdODEL INEKEMM C-15024 240 6.3 106 1/4" VOLTS 1.11101.11 TO YE/EATER VIfAT-fS i�TIm C IIS 13 " C-18008 1800 208 8.6 118 1/4" 20 lbs AMPS iT� C-18024 240 7.5 118 1/4" LISTED DATE C-20008 2000 208 9.6 132" NEVER BLOCK,COVER,OR PAINT THIS HEATER 22 lbs C-20024 240 8.3 132" 10 Year Limited Warranty Radiant Systems, Inc., will replace any heating element found to be defective for a period of ten years from date of purchase. All other components are warranted for a period of one year from date of purchase. Warranty does not apply to damage from accidents, misuse, or alteration, connected to voltage is 5% above the nameplate voltage, nor to equipment improperly installed, wired, or maintained in violation of the instruction manual. This warranty is only valid in the fifty states of the United States. All warranty items FOB: Radiant Systems,Inc. Radiant Systems,Inc.,will not be responsible for any incurred labor charges. RADIANT MADE IN Service, Questions &Warranty: YSTF1 I a m S A 1-800-314-9303 8AM-5PM CST 1006 West Highway 20 FAX: P.O. Box 47 Valentine, NE 69201 www.comfortcove.com 1-402-376-3064 Page I 4 INDEECO' Submittals Page 1 of 1 6/9/2023 Quote#: 376063 Job Name: Dartmouth Crossing Sales Rep: West Coast Air Products, Inc. Sales Person: Attn:Watt,Sharon 8800 SE SUNNYSIDE ROAD P:503-786-1412 Ext:111 CLACKAMAS,OR,97015 F:503-786-1413 P:503-786-1412 E:sharonw@wcap-inc.com F:503-786-1413 Line Qty Part# Description Factory Options 1 1 934U01000VW-T1 WLI-[934]Wall Heater 750W,208V,1 Phase,3.8A,gibs.[Availability Code-AS (T1]Tamperproof Thermostat,Single-pole,up ] to 25 Amps Tag:EWH-1 2 6 9340005008W-T1 WLI-[934]Wall Heater 500W,120V,Phase,4.6A,9lbs.[Availability Code-AS] [T1]Tamperproof Thermostat,Single-pole,up Tag:EWH-2,3,4,5,7,8 to 25 Amps 3 1 934U01500VW-T1 WLI-[934]Wall Heater 1125W,208V,1 Phase,5.6A,91bs.[Availability Code- [T1]Tamperproof Thermostat,Single-pole,up AS] to 25 Amps Tag:EWH-6 • • INDEECO-425 Hanley Industrial Ct-St I NANO 42144 NLI - [934] Wall Heater INDEECO' ;_ Catalog Number: 934U01000VW-T1 tilA Description: WLI - [934] Wall Heater 750W, 208V, 1 Phase, 3.8A, 9lbs. Color: White Almond X White Metallic Silver (Additional Charge) Aluminum (Additional Charge) Black(Additional Charge) Bronze (Additional Charge) Metallic Charcoal (Additional Charge) Job Name: Dartmouth Crossing Quote# Line# Qty Tag 376063 1 1 EWH-1 Selected Factory Installed Options: Option Code Description T1 Tamperproof Thermostat, Single-pole, up to 25 Amps Selected Field and Thermostat Options: No Options Selected. 3/9/2023 4:29:50 PM Page 1 of 1 NLI - [934] Wall Heater INDEECO Catalog Number: 934U00500BW-T1 Description: WLI - [934] Wall Heater 500W, 120V, Phase, 4.6A, 9lbs. Color: White Almond X White Metallic Silver (Additional Charge) Aluminum (Additional Charge) Black(Additional Charge) Bronze (Additional Charge) Metallic Charcoal (Additional Charge) Job Name: Dartmouth Crossing Quote# Line # Qty Tag 376063 2 6 EWH-2, 3, 4, 5, 7, 8 Selected Factory Installed Options: Option Code Description T1 Tamperproof Thermostat, Single-pole, up to 25 Amps Selected Field and Thermostat Options: No Options Selected. 3/9/2023 4:29:50 PM Page 1 of 1 WLI - [934] Wall Heater INDEECO Catalog Number: 934U01500VW-T1 Description: WLI - [934] Wall Heater 1125W, 208V, 1 Phase, 5.6A, 91bs. Color: White Almond X White Metallic Silver (Additional Charge) Aluminum (Additional Charge) Black(Additional Charge) Bronze (Additional Charge) Metallic Charcoal (Additional Charge) Job Name: Dartmouth Crossing Quote# Line# Qty Tag 376063 3 1 EWH-6 Selected Factory Installed Options: Option Code Description T1 Tamperproof Thermostat, Single-pole, up to 25 Amps Selected Field and Thermostat Options: No Options Selected. 3/9/2023 4:29:53 PM Page 1 of 1 WLI - [934] Wall Heater . Architect's and Engineer's Specifications The specified heating equipment shall include an electric,fan- tampering with the elements(pencil-proof). Contact factory forced air wall heater suitable for space heating as for custom colors. manufactured by INDEECO. The wall heater shall be designed Heater Element shall be of finned tubular type. for wall recess or surface mounting. Heaters shall be third Fan and Motor shall be thermally protected and have party approved to UL standard 2021. CSA-US or equivalent is permanently lubricated ball bearings. Fan shall operate at 40 acceptable. CFM for heaters up to 1000W and 80 CFM for all other Heater Housing shall be constructed from heavy 20 gauge models. steel. Thermal Cutout shall be of the bi-metal type and built into Grille shall have a white or almond epoxy/powder paint the system. finish. Grille openings shall be less than 0.25"to discourage cli" Mounting Positions I /.y Four mounting positions available. 1.(�I l ll ' _ i 1 Pictures showing front panel. IL'" 1 .•y°` Directional vane air flow. 1' 0 2"x3" Stud Wa l I Surface Box -= a1/8 Wall Opening Healer I sn a"i I 7 yi 6' 3' 3" 'fir Grille 3"� s 719"" r 16' 797/9' 0• ' J • --- A44 , ___-," Optional Surface Mounting Recess Mounting 5 - 0i 11) I ; 1111 O O O • ' $:cI Oil P' M (OPTION) #- THERMOSTAT GN D LAMP DOUBLE POLE I (Of'TIOM N L2 • INSTALLATION OPERATING MAINTENANCE N D E E C 0` .: i' INSTRUCTIONS INSTRUCTIONS INSTRUCTIONS Phone:(314)644-4300,Fax:(314)644-5332 wirFss WATT•MOUNTING- 1-The heater must be properly installed before it is used I- Once a year,remove the front panel and use a vacuum w•ww..ivdeeco.com I-Healer may be installed in any of four vertical position 2-Taro the power onat�arrant breaker panel. cleavemremove the dust accumulation inside the heater 3-Electronic thermostat be sure to set it on the fan mode. and through openings of the front panel. as shownmdmaieg. INSTRUCTIONS"WLI"Series 2-Provide an opening as shown on drawing,a minimum of 4-Built thermostat(optimal):to set thermostat at 2- Cleaning should be done while the heater is disconnected 3 in.(76 tam)deep.May he recessed in 2X3 in.stud wall the desired temperature,follow these steps: from the main service panel_Wait until the housing 3-Remove the 6 cm).ins knocked from the recess bur -Set thermostat at maximum temperature(turn clockwise). and hearing element teal before performing maintenance. WARNING /� for the electrical supply. heater -when Me desired rempemmeureached,taro the 3- tam line rant (before / \ mpPY Jtmcaon box volume thermostat Granter-clockwise Bowl until Pane ever performed . When elective fiances,basic shouldd 4-u33lvi(5eser or a"click". Y you hear 4- � servicing shoddbaperFarmed by aqualified using appliances, precautions sheway, Install che Meanly witerecersbde screws. Make the heater be taken b radian the risk of fire,electrical shank end injury, is edge firmly with t provided screws.Make sure that -The thermostat will keep this roomknob, the eemg c including the following. the edge on each side of the rams box lean on the gypsum 5- Built-iv thermostat with control located the setting can be panel and npton the grummetboet parts of the wall See marking done with the supplied knob. on the front cover. Read carefully these instructions before installation,operation m the sides of the recess box IMPORTANT.If the recess box 6- Built-in mmperpr of thermostat the setting can be done of the heater.Failure to adhere to the instructions could result in is installed,insert the through the hole in the from cover with a small slotted fro,electric shock,serious mPre- keyholes tethe venture screws the persconl injury, death and y to prevent the recess box and thipJtten the4 AMERIver. damage.Review frequently for continuing safe operation and C prevrm the heater l 7-vsuall alarm he s VERSION ONLY:be This heater include a imtmcetonoffdure seem,if necessary. 5-Connectdturn ofeadatothotioss lacdedancengbthe r'isuddemmwmn thighs parts heater asegevivg Four mounting positions available IMPORTANT inan;ngiiag,codes.eiostrutiwa accordance with local excessively hot If the light term on,mmediatelyrum the �; end ordinal cads. heater off and inspect for any objects on or adjacent b the I INSTRUCTIONS Install thebladeleasmgtheprovrdedccdwe.Makesurethal heater that may have blocked the airflow or otherwise i Lr the fen bladenfrmbmtate and the heater assemblythen is free caused high temperatures THE b have o«ured. Jy� l- Read allter is before installing or using this huts of foreign objects and/or matter_Make sure that solid DO NOT OPERATE THE HEATER WHEN THE 2- This heater is hot when in use.To avoid bums,do not let bare panel of the grille covers the supply connection box. ALARM LIGHT 1)i ON. skin touch hot surfaces.Keep combustible materiels,the 7-Tut heater by temporaly adjusting the thermostat at furniture,pillows,bedding,papers,clothes,and curtains at maximum temperature. Least 36 in.(915 mm)from the front of the heater and away Wa�"w•a" sr Ming diagram 120V,208V,240V from theaidea. SURFACE WALL MOUNTING. it"i 1Ytl 3- Extreme caution isnec any when any heater is used by or 1-Heater(and surface box)may be installed in any of four it S ' near children or invalids and whenever the heater u left vertical.,dons(See drawing). d IV �� N D '' O O a' operating and unattended. 2-Locate power supply leads behind the surface box. m 4- Do not operate any heater after it inspected Disconnect 3-Mount the surface box securely to the wall with the provided ^- 7 �pa. `utiwn' ra050ers power at service panel and have heater inspected by a screws. awuev«s reputable electrician before reusing. 4-Follow instructions 3 m 7 mentioned previously in the recess affo� l _ s1N M nua,u : GN�I 5- Do not use outdoors. wall mounting section. s • 04 s/10_111,106ae 1 1 6- Do not insert or allow foreign objects to enter any ventilation toTa Qa 1T tmnut _ ©m am age th enealer.s may cause m el«mc air«k dfid. OPT the ]NFRMOCThn ti %ly ps =O • mdamage the hate Refer to the instruction supplied with the option. �' ' 1a _"j In 7- Do not block air intakes err exhaust in any way whatsoever. fi. 8- ThDo o uert sin hot and arcing soline,ipvg parts nside. ghITTOe' grnly RAMP) Do not use iced areas where gasoline,paint,or flammable High hige,temperature,o other of fire,keep electrical cord(,drapery, • only RAMP) liquids Use thsare andnlstored filthe frotof and utterandawsy from sides. (red mm)from 9- Use this heater only d the bedma in this manual.Au other the front do of the heater and away the r flat To reduce vapors theors and genic recommended by the manufacturer my cause Erie, liquid,in not store use gasoline m other flammable velure and elMERic shock,orivj liquids in the vicinity of the heater. Recess Wiring diagram 347V 10-AMERICAN VERSION ONLY:This heater includes tting bet nB mg visual alarm to warn that pun of the heater are getting nwew.r meem7 excessively hot.If the light tans on immediately bean the IMPORTANT !,01:._cir ' Veined heater off end inspect for any objects on or adjacent tothe I-De not obstruct the front of the heater fax at least Vemud 120V �90N east heater that may have blocked the airflow or otherwise 48 in. 1200 tam. 39N 20oV caused high tereaer.e u b have emoted If no obstruction 2-Install ihc heater withdue air outlet at least 24pV all—L� • . visible,the heater must be checked by a qualified person. 10 in(254mm) i.;\ ��P DO NOT OPERATE THE HEATER WHEN THE IMPORTANT: ALARM LIGHT IS ON. Don the floor or adjacent surface at 4c.t The Venmd GND II-The thermostat steroid not he considered an infallible device in 3-Al ndvWall thcv eaterutat in of hdamdaaerely css well. Al*- �,' caeca where maintaining temperature is considered critical. `always install the heater m the well with the recess box. meet ba used • Examples:Ilmardous material storage.computer server mom, _ re/ weir tan M recess hex. etc.In these particular cues,it is imperative to add a monitoring system to avoid the consequence of a thermostat failure. airroote two Vy_O, 12-Use only with copper branch circuit. P• N� SAVE THESE INSTRUCTIONS ENM-3800-OO • ••• INDEECO m . ..:•• LIMITED WARRANTY Indeeco new products are warranted against defects in workmanship, material, design, labeling and packaging. No other warranty, expressed or implied, written or oral, applies. No person other than an officer or the general manager of Indeeco is authorized to give any other warranty or assume any liability. Warranty Period 18 months from the date of shipment from Indeeco's factory, or 12 months from the date the product is first placed into service, whichever period lapses first. Conditions of Warranty Indeeco products must be installed, operated, and maintained in accordance with Indeeco's instructions. Indeeco is not liable for damage or unsatisfactory performance of the product resulting from accident, negligence, alteration, unauthorized repair, improper application or installation of the product, improper specifications, or corrosion. Indeeco IS NOT LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES. Claims against carriers for damage in transit must be filed by the purchaser with the carrier. Remedy Contact Indeeco sales department at (314) 644-4300 or sales@Indeeco.com, for a Return Material Authorization Number (RMA#) and return instructions. If after receipt of the product and the claim, Indeeco finds to its reasonable satisfaction that the product is defective in workmanship, material, design, labeling or packaging, the product will be repaired or replaced, or the purchase price refunded at Indeeco's option.There will be no charge to the purchaser for parts or labor. Removal and reinstallation of the product, and shipment of the product to Indeeco for repair or inspection, shall be at the purchaser's risk and expense. THE REPAIR, REPLACEMENT, OR REFUND PROVIDED FOR IN THIS LIMITED WARRANTY IS THE EXCLUSIVE REMEDY OF THE PURCHASER. THIS WARRANTY IS EXPRESSLY IN LIEU OF ANY OTHER, INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE TERMS OF THIS LIMITED WARRANTY. MKL - 3593 - 01 15860 SW Upper Boones Ferry Rd II 0 Lake Oswego,OR 97035 4irRep Phone 238 0.4300 fax 503.620.620-4238 airreps.corn RECEIVED SUBMITTAL JUN 2 0 2023 CITY OF TIGARD BUILDING DIVISION Project: Dartmouth Crossing Tigard,OR Contractor: Hunter Davisson Portland,OR Engineer: Hunter Davisson Portland,OR Specification Section: Daikin Split System F OAIKIN AC Manufacturer: absolute comfort Qty Model No. Description Tag 1 FTK12AXVJU 1.0 TON WALL MOUNT IU FCU-8 1 RK12AXVJU 1.0 TON COOLING ONLY CONDENSING UNIT CU-2 1 FTX3ONVJU 2.5 TON WALL MOUNT IU FCU-7 1 RK3ONMVJU 2.5 TON COOLING ONLY CONDENSING UNIT CU-1 3 FBQ18PVJU 1.5 TON DUCTED CONCEALED SKYAIR FCU FCU-2,-3,-6 3 RZQ18TAVJUA 1.5 TON HEAT PUMP CONDENSING UNIT HP-2,-3-,-6 1 FBQ24PVJU 2.0 TON DUCTED CONCEALED SKYAIR FCU FCU-1 1 RZQ24TAVJUA 2.0 TON HEAT PUMP CONDENSING UNIT HP-1 1 FBQ36PVU 3.0 TON DUCTED CONCEALED SKYAIR FCU FCU-5 1 RZQ36TAVJUA 3.0 TON HEAT PUMP CONDENSING UNIT HP-5 1 FBQ48PVJU 4.0 TON DUCTED CONCEALED SKYAIR FCU FCU-4 1 RZQ48TAVJUA 4.0 TON HEAT PUMP CONDENSING UNIT HP-4 2 FTXS12LVJU 1.0 TON WALL MOUNTED FCU FCU-9,-10 1 3MXS24WMVJU9 2.0 TON 3 PORT MULITPORT CONDENSING UNIT HP-7 2 FTK24AXVJU 2.0 TON WALL MOUNT IU ACCU-403,-404 2 RK24AXVJU 2.0 TON COOLING ONLY CONDENSING UNIT AC-201,-301 6 BRC1E73 NAV WIRED REMOTE CONTROLLER 4 BRC944B2 WIRED REMOTE CONTROLLER 208/60/10 voltage Air cooled condensing units Ducted concealed fan coil unit Wall mounted fan coil units Notes: 1. Skyair split systems require separte power for the indoor units and the outdoor units 2. Refrigerant is provided by others 3. Refrigerant piping and specialties are provided by others 4. Installation by others Rob Grace Air Reps, Inc. Job Name: Tag# Submittal Data Sheet FTK12AXVJU / RK12AXVJU 1-Ton Wall Mounted Cooling Only System Efficiency Cooling / SEER 19 EER 12.5 * i_____, �� �J'f`.j` Performance I �/ Cooling(Btu/hr) ++ f , Rated(Min/Max) 10,900(4,400/13,300) tft � F Q NTY Sensible @ AHRI 9,090 Moisture Removal gal/h .19 Standard Operating Range 50°F—115°F Complete warranty details available from your local dealer or at Extended Operating Range* -4°F-115°F www.daikincomfort.com.To receive the 12-Year Parts Limited Warranty,online registration must be completed within 60 days of Rated Cooling Conditions: Indoor:80°F DR/67°F WB installation.Online registration is not required in California or Quebec Outdoor:95°F DB/75°F WB If product is installed in a commercial application,limited warranty *With field settings and wind baffle period is 5 years. Indoor Specifications Electrical Cooling 208/60/1 230/60/1 H M System MCA 7.8 7.8 Airflow Rate(cfm) 436 316 System MFA 15.0 15.0 L SL Compressor RLA 7.5 7.5 247 132 Outdoor fan motor FLA .47 .47 Sound(dBA) 45/37/31/19 Outdoor fan motor W 41 41 H/M/L/SL Indoor fan motor FLA .36 .36 Dimensions(H x W x D)(in) 11-1/3 x 30-29/32 x 9-27/32 Indoor fan motor W 38 38 Weight(Lbs) 22 MFA: Max.fuse amps MCA:Min.circuit amps(A)FLA:Full load amps(A) RLA:Rated load amps(A) W:Fan motor rated output(W) Outdoor Specifications Compressor Hermetically Sealed Swing Type Piping Refrigerant R-410A Liquid(in) 1/4 Factory Charge(Lbs) 2.09 Gas(in) 3/8 Refrigerant Oil PVE(FVCSOK) Drain (in) 3/4 Cooling Max. Interunit Piping Length (ft) 65.625 Airflow Rate(cfm) H 1,051 Max. Interunit Height Difference(ft) 49.25 Sound Pressure Level(dBA) 49 Chargeless (ft) 32.8 Dimensions(H x W x D)(in) 21-11/16 x 26-1/2 x 11-3/16 Additional Charge of Refrigerant(oz/ft) .21 Weight(Lbs) 62 Daikin North America LLC 5151 San Felipe,Suite 500 Houston,TX 77056 (Daikin's products are subject to continuous improvements.Daikin reserves the right to modify product design,specifications and information in this data sheet without notice and without incurring any obligations) Submittal Revision Date:August 2020 Page 1 of 4 FTK12AXVJU Dimensional Data DAIKIN C v W o - z K 4_ -0 �I m 0 o — Il bl -1 z m o -n o O -0 o w m + .. .., I I r N D CS) m D z N m -1 r- o I V m W III D (Ti , mom N 0IT 9 . ir D 1i i X co — ,, ) `—► O X —1 I K r� } N i v V/ W Q N m I N C • 3 11-1/3 (288)cil z Ko m mm m �I- I— D 3 m 0m 3 3 1 Daikin North America LLC 5151 San Felipe,Suite 500 Houston,TX 77056 (Daikin's products are subject to continuous improvements.Daikin reserves the right to modify product design,specifications and information in this data sheet without notice and without incurring any obligations) Submittal Revision Date:August 2020 Page 2 of 4 I RK12AXVJU Dimensional Data , DAIK//VI Q. . E J___ 0 _ , 1 ____... 1 0 0 m . ._...... .... _____.._. m g J { n IT O1 N A N I cs' A IJIIIIIIII"1`1:;i Iii1U":4,.1IIIIIIIIL' iii• ill [- I. ; IIIIII!► o Iilillll IIIIIIIlIIIII1ii;►!=!III1 i E i• it N " III��'ii111IIIIIIIIIIIIIIRIIIIIU 11111Ih!i! ' II" "' I•:` Illllllllllllil N m r ill illiiiiiiil')" cn I Il1i11111110111111.6VIIIIIIIIIIIIV I liiiiliqIM!!II !IIIIIIIIIIiiiiiiiiili!i a ; I 11111i1 1111IIIIIIIiil1!il!I!I! iIll L1 0 11111III1II"i!:°liijia;l :iiNIIIIIIIt Lr • 1� csa .a --' -irb 1 f g M K G. I� co N co P Ir- PP 8g r" D • O N 3 g 1 : __ _ � O • � • N ....-- r 1_ V S. n N O 3 —� N -4 N 3 Daikin North America LLC 5151 San Felipe,Suite 500 Houston,TX 77056 (Daikin's products are subject to continuous improvements.Daikin reserves the right to modify product design,specifications and information in this data sheet without notice and without incurring any obligations) Submittal Revision Date:August 2020 Page 3 of 4 Job Name: Tag# FDAIKIN Submittal Data Sheet FTX3ONVJU / RK3ONMVJUA 2.5-Ton Wall Mounted Cooling Only System Efficiency Cooling SEER 17.50 1 1 . EER 9.85 �J�f�r,"-�r? --- Performance p� _Jr:J = = • Cooling(Btu/hr) /� -� (^I °_____ Rated(Min/Max) 31,400(10,200/31,400) i Pr7i !\ T`f ==_ Sensible @ AHRI 21,030 Standard Operating Range 50°F-115°F - Extended Operating Range* -22°F-115°F Rated Cooling Conditions: Indoor:80°F DB/67°F WB Outdoor:95°F D8/75°F WB Complete warranty details available from your local dealer or at *With field settings and wind baffle www.daikincomfort.com.Warranty registration not required to receive the 10-Year parts limited warranty for residential or commercial installations. Electrical Indoor Specifications 208/6o/1 230/60/1 Cooling System MCA 17 17 H M System MFA 20 20 Airflow Rate(cfm) 890 727 Compressor RLA 16.25 16.25 I. SL Outdoor fan motor FLA .62 .62 572 512 Outdoor fan motor W 93 93 Sound(dBA) 53/47/40/37 Indoor fan motor FLA .37 .37 H/M/L/SL Indoor fan motor W 64 64 Dimensions(H x W x D)(in) 13-3/8 x 47-1/4 x 10-3/16 MFA: Max.fuse amps MCA:Min.circuit amps(A)FLA:Full load amps(A) Weight(Lbs) 38 RLA:Rated load amps(A) W:Fan motor rated output(W) Outdoor Specifications Compressor Hermetically Sealed Swing Type Piping Refrigerant R-410A Liquid (in) 1/4 Factory Charge(Lbs) 3.64 Gas (in) 5/8 Refrigerant Oil PVE(FVC50K) Drain(in) 5/8 Cooling Max. Interunit Piping Length (ft) 98.4 Airflow Rate(cfm) H 2,528 Max. Interunit Height Difference(ft) 65.625 Sound Pressure Level(dBA) 56 Chargeless(ft) 32.8 Dimensions(H x W x D)(in) 28-15/16 x 34-1/4 x 12-5/8 Additional Charge of Refrigerant(oz/ft) .32 Weight(Lbs) 133 Daikin North America LLC 5151 San Felipe,Suite 500 Houston,TX 77056 (Daikin's products are subject to continuous improvements.Daikin reserves the right to modify product design,specifications and information in this data sheet without notice and without incurring any obligations) Submittal Revision Date:October 2021 Page 1 of 4 FTX3ONVJU Dimensional Data FDA 1-3/4(4 mm) 9/16(14.5mm) f m I _I 1 N * . 23 cb ' m J _ — O i -I W a m x z 3 3 0 ` m g 3 Om D. O m m i h m p V 1 N 4. 0 o v w 0 4:- o Cn O O N f!1 S -to* 3 3 3 -a D 3 z > m 3 v G) r* gx 0 x Ca CO 70 m m "�3 m\ °° 9 m CDx 0 • 0 3 0 3 ,: z P-'m + 3 1-3/4(45mm) 5/8(16mm) I 73 8.1/4(210mm) t2 13-3/8(340mm)` 13-3/8(340mm) K - c m O r LEI 3 3M Z , 3 3 m 3 � to —I -0 Z m — rm r > 7J I = 0I gm m D1 � D mm 55 c14,1 \� r l- c m Z o O 'a D * m m 1 7-7/16(188.7mm) m m N Co m-CO ^yx CD 20i 7o m Q —1 m g O O i 0 3 D m In 3 m v O Z al � f ) ,� O F- 1.3/16(30mm)MIN xi (SPACE FOR PERFORMANCE) Daikin North America LLC 5151 San Felipe,Suite 500 Houston,TX 77056 (Daikin's products are subject to continuous improvements.Daikin reserves the right to modify product design,specifications and information in this data sheet without notice and without incurring any obligations) Submittal Revision Date:October 2021 Page 2 of 4 Z a r o m g m a .1▪1111 a ( )HANDLE 9/16 14 34.1J4 970 2-3/4 70 v ( > ( ) 1/4(7) 12.5/8(320) 1.3/16(30) BRAND NAME PLATE ELECTRIC WIRE INTAKE OUTDOOR AIR THERMISTOR Y Q .c_� , 1 4, P . .�: c �' n. CI rIli' I'7 1IlMMMEIIIM1=MM.II1I 1 1 I. 0orc.'-od•. ...-..iI-D•i/:/N1....- 3/4 19 �` C ;= ' - '+ ® J MANUFACTURER'S LABEL -o 1Is \ 1 j \ [liii _al c a 4-HOLES FOR FOUNDATION BOLTS 9/16 14.5 7/B 23 ;; - c (M8 OR M10) 23-5/8(600) 4-15/16(125) 13.5l8(346 I 7/16 11 `^ . m (INSTALLATION LEG n.z c /13 N O — 14-1/2(368 n o 5 ao ` N L L o ti no 1 O I ' MINIMUM SPACE FOR AIR PASSAGE WALL HEIGHT ON AIR OUTLET SIDE g J « 9 Q 2-GROUND TERMINALS ( _, 0000 0 / =LESS THAN 47.1l4(1200) 41 :- u a a �tUOUID ID a,05 •V I -T; STOP VALVE , 20-11/16 525)w �iiniiui.v.,miiuiiirrai I % E c O r; (0114(46.4)CuT) DRAIN OUTLET i STi1-15716 r c t Y B GAS (I.D 05/8 015.9)HOSE FOR i o m STOP VALVE CONNECTION WITH DRAIN JOINT) o ($5/8(415.9)CuT) y g g92, s .'"• co ej C SERVICE 1-15/16(50) 1-15/16(50) C PORT Al m c� cb ch EL" Q ' `i• 6 uioruiviiirvvuirirvri ,,,zzzJIJIil«iiriivvid ! I = I I N 6-13/16 173 IN CASE OF REMOVING a UNIT:Inch(mm) ° a STOP VALVE COVER AND 0 m 0 2 TERMINAL STRIP COVER c ii I y o II o N Optional Accessories 7DA Indoor Unit Included Part Number Description AZAI6WSCDKB DKN Residential Cloud Wi-Fi Adaptor for Single-and Multi-Zone System(S21) AZAI6WSPDKC DKN Plus Interface DTST-ONE-ADA-A Daikin One+Smart Thermostat for Ductless Products BRC944B2 Wired Remote Controller BRCW901A08 Wired Remote Controller Cable—25ft BRCW901A03 Wired Remote Controller Cable—10ft DACA-CP1-1 Inline Condensate Pump(Fits inside all Daikin wall&floor mount units) DACA-CP4-1 External Condensate Pump KRP928BB2S Interface Adaptor for DIII-NET Outdoor Unit Included Part Number Description KPW063B4 Air Adjustment Grille(RX&RK) KKG063A42 Back protection wire net Daikin North America LLC 5151 San Felipe,Suite 500 Houston,TX 77056 (Daikin's products are subject to continuous improvements.Daikin reserves the right to modify product design,specifications and information in this data sheet without notice and without incurring any obligations) Submittal Revision Date:October 2021 Page 4 of 4 VDAIKrn Submittal Data Sheet 1.5-Ton DC Ducted Unit FBQ18PVJURZQ18TAVJUA FEATURES BENEFITS • External static pressure(ESP)capabilities up to 0.8"W.G. • DC fan motor provides improved efficiency • Three user selected fan speeds available plus fan"Auto"logic • Bottom access for easy service • Low ambient cooling operation down to 0"F(with optional wind baffle(s)) • Built-in condensate pump • Maximum piping length up to 164 ft allows flexible placement of indoor unit • Maximum piping height separation up to 98 ft. • 10 year limited parts and compressor warranty INDOOR UNIT OUTDOOR UNIT 111 tlflla iS%�\wQ \ IHfluirer *Av >,1 .. � II Daikin North America LLC,5151 San Felipe,Suite 500,Houston,TX,77056 Daikin City Generated Submittal Data www.daikinac.com www.daikincomfort.com (Dalkin's products are subject to continuous improvements.Daikin reserves the right to modify product design,specifications and information in this data sheet without notice and without incurring any obligations) Submittal Date:October 2021 Parse 1 of 4 VDAIKIN • Submittal Data Sheet 1.5-Ton DC Ducted Unit FBQIBPVJURZQIBTAVJUA SYSTEM PERFORMANCE Indoor Unit Model No. FBQ18PVJU Indoor Unit Name: Sky-Air DC Ducted Outdoor Unit Model No. RZQ18TAVJUA Outdoor Unit Name: Sky-Air Heat Pump ODU Rated Cooling Capacity(Blu/hr): 18,000 Rated Cooing Conditions: Indoor my ent(FDB/WB):956 75 Sensible Capacity(Btulhr): 14,800 Rated Piping Length(ft): 25 Max/Min Cooling Capacity(Btulhr): / Rated Height Difference(ft): 0.00 doorCooling Input Power(kW): 2.120 Rated Heating Conditions: Ambient(F DBIWB):476 43 SEER(Non-Ducted/Ducted): /16.70 HSPF: /9.5 EER(Non-Ducted/Ducted): /13.00 Rated Heating Capacity(Btu/hr): 20,000 SYSTEM DETAILS Refrigerant Type: R-410A Cooing Operation Range(°F DB): 23-122 Holding Refrigerant Charge(Ibs): 6.4 Heating Operation Range(°F WB): -4-60 I Additional Charge(Ib/It): 0.04 Max.Pipe Length(Vertical)(ft): 98 I�'1 Pre-charge Piping(Length)(ft): 15 Cooling Range w/Baftle(°F DB): 0-122 Max.Pipe Length(Total)(ft): 164 Heating Range w/BaffF WB): -l(° Max Height Separation(Ind to Ind ft): 0 Daikin North America LLC,5151 San Feipe,Suite 500,Houston,TX,77056 Daikin City Generated Submittal Data www.daikinac.com www.daikincomfort.com (Daikin's products are subject to continuous improvements.Daikin reserves the right to modify product design,specifications and information in this data sheet without notice and without incurring any obligations) Submittal Date:October 2021 Page 2 of 4 f Submittal Data Sheet 1.5-Ton DC Ducted Unit FBQ18PVJURZQ18TAVJUA INDOOR UNIT DETAILS Power Supply(V/Hz/Ph): 208-230/60/1 Airflow Rate(H/M/L)(CFM): 635/582/529 Power Supply Connections: L1,L2,Ground Moisture Removal(Gallhr): Min.Circuit Amps MCA(A): 1.6 Gas Pipe Connection(inch): 5/8 Max Overcurrent Protection(MOP)(A): 15 Liquid Pipe Connection(inch): 3/8 Dimensions(HxWxD)(in): 11-13/16 x 39-3/8 x 27-9/16 Condensate Connection(inch): 1 Net Weight(lb): 80 Sound Pressure(H/M)(dBA): 41/39 - Ext.Static Pressure(Rated/Max)(inWg): 0.8/0.8 Sound Power Level(dBA): 30-03 161•le1_1/16 24-13/16 fall eroued) Ductwork Opening: I.laatnaein Hit HateslU Supply Opening Return Opening F8C118PVJU '" 36-/3/16NI1 Model No. Unit(in. 'MIIA ) Height Width Height Width ) FSQISIWIU 9-5/3" 30-7/S" 10-7/8" 37-3/8' O (Note:Opening dimension One on Firing Hole Center) cast II ilaRttlHe aHtl I Y'', $ O I (11-371tex17-3/diol �1 Caatral butt Ail _ =-- Ail iAltt tn,nil box outlet E I .r If-5/16XI leiu. HIS (Ali lrlrad) Impel elcq teiHlt/ eir a e•u wr 41 ® 0 in Ile Zia \ 'I .- Ia1Hl nitt �l1 _1 S>•:Zu• "I 'S - os .. 1-1h1 r (II- lea Btel l • i' CMI 1L 31 111- IAA 7-7 lia) it 7 w —� untie an envoi lox rn a i! 5X5-7/8..29-1/2 meelt :1.. ---- ; I Isis alnt iw11 3 a ' ; .0 29-15/16 0 e I ` , �',I _ s i Sla HI-IY11 w fY l•' coltn�lLwx 2+ Z30-7/8 y —t s a I I �� I view 4e telne ii Ia�. M ,21?✓r Ines , 1 leetecI ioi flit. ea 1[� 111pUltll Leta J ISen--motel 'y i (Free IAe Air IRMO iB 11q/131T-3/1 er gent / '�------ lee Here.latch 2 er are ...MN • -�1_l H-a/Ifx I/7111111 bolo PM a r AS THE I a :_, Air inlet kH I201 inr (tllte.2) , , 2.- 1. Zell eroled) Ow SHEIMP Y,iiY.�). Yyt1.1.1. 6 Air outlet�- 1 7•1 1 _ r'�I f iii ll _ — tt3.. Nf•PLA-I l• _ i-pli 1,, !)llll 9ib6 � �'1 1 �oL�ttMh)IY LI - o 0�_In._ ii' .,X,, _, _ .1... - 36-7/•6 N .. _ 37-3/: Ceillig Hear surface (Roe tit Air islet) Daikin City Generated Submittal Data www.daikinac.com www.daikincomfort.com (Daikin's products are subject to continuous improvements.Daikin reserves the right to modify product design,specifications and information in this data sheet without notice and without incurring any obligations) Submittal Date:October 2021 Page 3 of 4 , Submittal Data Sheet 1.5-Ton DC Ducted Unit FBQ18PVJURZQ18TAVJUA OUTDOOR UNIT DETAILS Power Supply(VIHz1Ph): 208-230/60/1 Compressor Stage: Power Supply Connections: Lt,L2,Ground Capacity Control Range(%): 14-100 Min.Circuit Amps MCA(A): 16.5 Airflow Rate(H)(CFM): 2682 Max Overcurrent Protection(MOP)(A): 20 Gas Pipe Connection(inch): 5/8 Max Starting Current MSC(A): Liquid Pipe Connection(inch): 3/8 Rated Load Amps RLA(A): 15.3 Sound Pressure(H)(dBA): 58 Dimensions(HxWxD)(in): 39 x 37 x 12-5/8 Sound Power Level(dBA): Net Weight(lb): 172 3-9/16(90) 5/8 i.,„..i i _i_,m_..._r..,.v._,8..115M.. l l ii.o. c'F.r,I..J ,:.,.-. f--r,;,•• 11`-I_'-* .01•11.11 ■I 1 m wm .,. , ,,, _. Hole for anchor bolt �� _ I7-3. 642) bolt Utrif v i 1/ NCUgitim pos)(6-M722 3-9/1:61 i3 77(9W) 4. .....„... 1. t ... I■■■■■■1 i■■■■■■ i rWye. �\ 0 p11 ii 00 i h,;11,1: ; tllll • I■■■■■■I OO P s %%��//. al , I■■■■■■ 00 HR . . _ %�2. 3 m I:g r 0 I■■■■■■ ,,,' ' i — • . I ry.. .�", 3M ii13-1/ 80) B 2-1/I:52 _ 19, ll� 1/IB 1/ IN /a67 (I65 13) 3-1/2(691 11 3/409 5-9/1 162) Daikin North America LLC,5151 San Felipe,Suite 500,Houston,TX,77056 Daikin City Generated Submittal Data www.daikinac.com www.daikincomfort.com (Daikin's products are subject to continuous improvements.Daikin reserves the right to modify product design,specifications and information in this data sheet without notice and without incurring any obligations) Submittal Date:October 2021 Page 4 of 4 e ,. Submittal Data Sheet 2.0-Ton DC Ducted Unit FBQ24PVJURZQ24TAVJUA FEATURES BENEFITS • External static pressure(ESP)capabilities up to 0.8"W.G. • DC fan motor provides improved efficiency • Three user selected fan speeds available plus fan"Auto"logic • Bottom access for easy service • Low ambient cooling operation down to 0°F(with optional wind baffle(s)) • Built-in condensate pump • Maximum piping length up to 164 ft.allows flexible placement of indoor unit • Maximum piping height separation up to 98 ft. • 10 year united parts and compressor warranty INDOOR UNIT OUTDOOR UNIT h '.» 'i ,'v Fl tip t j Daikin North America LLC,5151 San Felipe,Suite 500,Houston,TX,77056 Daikin City Generated Submittal Data www.dailinac.com www.daikincomfort.com (Daikin's products are subject to continuous improvements.Daikin reserves the right to modify product design,specifications and information in this data sheet without notice and without incurring any obligations) Submittal Data'Octnher 2021 Pane 1 of 4 . . VDAIKIN Submittal Data Sheet 2.0-Ton DC Ducted Unit FBQ24PVJURZQ24TAVJUA SYSTEM PERFORMANCE Indoor Unit Model No. FBO24PVJU Indoor Unit Name: Sky-Air DC Ducted Outdoor Unit Model No. RZO24TAVJUA Outdoor Unit Name: Sky-Air 2.0 Ton Heat Pump ODU Rated Cooing Capacity(Btulhr): 24,000 Rated Cooling Conditions: Indoor(°F DB/WA):80/67 Ambient(°F DBMlB):95175 Sensible Capacity(Btu/hr): 18,700 Rated Piping Length(ft): 25 Max/Min Cooling Capacity(BtWhr): I Rated Height Difference(ft): 0.00 Cooling Input Power(kW): 2.120 Rated Heating Conditions: Indoor(°F F D pj):). 7/ Ambient(°F DB/WB):47/43 SEER(Non-Ducted/Ducted): /16.50 HSPF: /9.7 EER(Non-Ducted/Ducted): /12.00 Rated Heating Capacity(Btulhr): 27,000 SYSTEM DETAILS Refrigerant Type: R-410A Cooling Operation Range(°F DB): 23-122 Holding Refrigerant Charge(Ibs)y 6.4 Heating Operation Range(°F WB): -4-60 Additional Charge(lb/ft): 0.04 Max.Pipe Length(Vertical)(ft): 98 Pre-charge Piping(Length)(ft): 15 Cooling Range w/Baffle(°F DB): 0-122 Max.Pipe Length(Total)(fly 164 Heating Range w/Baffle(°F WB): - Max Height Separation(Ind to Ind ft). 0 Daikin North America LLC,5151 San Felipe,Suite 500,Houston,TX,77056 Daikin City Generated Submittal Data www.daikinac.com www.daikincomfort.com (Daikin's products are subject to continuous improvements.Daikin reserves the right to modify product design,specifications and information in this data sheet without notice and without incurring any obligations) Submittal Date:October 2021 Page 2 of 4 'DAIKIN Submittal Data Sheet 2.0-Ton DC Ducted Unit FBQ24PVJURZQ24TAVJUA INDOOR UNIT DETAILS Power Supply(V/Hz/Ph): 208-230 1 60/1 Airflow Rate(H/M/L)(CFM): 688/618/565 Power Supply Connections: L1,L2,Ground Moisture Removal(GaVhr): Min.Circuit Amps MCA(A): 1.8 Gas Pipe Connection(Inch): 5/8 Max Overcurrent Protection(MOP)(A). 15 Liquid Pipe Connection(inch): 3/8 Dimensions(HXWxD)(in): 11-13/16 x 39-3/8 x 27-9/16 Condensate Connection(inch): 1 Net Weight(lb): 80 Sound Pressure(H/M)(dBA): 42/40 Ext.Static Pressure(Rated/Max)(inWg): 0.8/0.8 Sound Power Level(dBA): 30- 3 I.MiI11-1/16 24-13 16 Ductwork Opening: (AII graved) florenlia(Mt laetti0e) Model No. Supply Opening Return opening FBO24 3OPVJU t' 36-/3/16b1e Height Width Height Width Unit(In.) �I Idle an11d1 F5024,30PVJU I9.5/8" 30-7/8" 30-718" 37-3/8" (Note:Opening<grnension base an Fairy Hole Center) Y _ ® IMpe<t in god l CASE II t�1 Control pae Air � — � �� - -- Air inlet !� Cxtrdl Ilx outlet E 11 [17I � r 16-5/16X I/1111111 Oil '� ® Q tdil lrla ado 1 tlae<tlo talgteaw 1 A:e d p e ® e Air to �i� aallt oleo Z� Si °l M� i � _tC� e 1 �� , S l lE=5 18 1/2 t m 6vatiaa Old I � 1 - SdSE tj,3) 11- IM19- II p I- 4 la 1 $ !1 an In-NII M opal t. /. vie* t1H wile, i 'MIN I, ,284; m0 re\ I -� ins rett Ina Sat< ;� '✓ �11�_ I AS Htti01 leatt1 Mince men_• lens the Air ortletl 8 I1-U111i-3/1 it OM .. CA --' insee I5 rH aaaq o Ore at Asir : 11-S/1Ix1/211Hg1 Milt SAM IS IIE IO0NA et I y MI Silt Olt wall ylev B_I ri l 6-• 15d' hit inlet ISn 1pa 2C-3/161"11 dratea) ��ldote.2) -J♦ _' I FI li011;mI .i 1�I ��� ■IIIF� ,_i � �n�� E] Ira r mootI!!J4!J. S ar _ an i ro e 5X5-7/e=35-_!a fi an 1 I • '� to n. a Ceil ilia F190r affect (F111 the A i t illetl Daikin North America LLC,5151 San Felipe,Suite 500,Houston,TX,77056 Daikin City Generated Submittal Data _ www.daikinac.00m www.deikincomfort.com (Daikin's products are subject to continuous improvements.Dann reserves the right to modify product design,specifications and information in this data sheet without notice and without incurring any obligations) Submittal Date:October 2021 Page 3 of 4 VD*IKIN Submittal Data Sheet 2.0-Ton DC Ducted Unit FBQ24PVJURZQ24TAVJUA OUTDOOR UNIT DETAILS Power Supply(V/Hz/Ph): 208-230/60/1 Compressor Stage: Power Supply Connections: L1,L2,Ground Capacity Control Range(%): 14-100 Min.Circuit Amps MCA(A): 16.5 Airflow Rate(H)(CFM): 2862 Max Overcurrent Protection(MOP)(A): 20 Gas Pipe Connection(inch): 5/8 Max Starting Current MSC(A): Liquid Pipe Connection(inch): 3/8 Rated Load Amps RLA(A); 15.3 Sound Pressure(H)(dBA): 58 Dimensions(HxWxD)(in): 39 x 37 x 12-5/8 Sound Power Level(dBA): Net Weight(lb): 172 3-9/18(90) 5/8 1. ■I 18 W ;i, II i i.,., • I110 MI_ �' Hole foranchor bok II/% -_0-$:9dd2) Colt 1/2U C pocRiona4-al 3_ 691_ X T • �II o I a 1■■■■■■ �O= //„ ,•: , I [1 I■■■■■■00 rr , , :.0 o CIO g III ,;) , . . I IO I■■■■■■ l f II �° : i ' ■■■■■■ 0O p �� m I ail�C j' 1 m - 1k nne- D I ■ I s *lit I!'U'fll'!19 M _II/It n 1/ lilt 5/>6/ a 145) 3-1/2(89).�I , 3/409) 5-9/16(142) Daikin North America LLC,5151 San Felipe,Suite 500,Houston,TX,77056 Daikin City Generated Submittal Data www.deikinac.com www.daikincomfort.com (Daikin's products are subject to continuous improvements.Daikin reserves the right to modify product design,specifications and information in this data sheet without notice and without incurring any obligations) Submittal Date:October 2021 Page 4 of 4 rDAIKIN Submittal Data Sheet 3.0-Ton DC Ducted Unit FBQ36PVJURZQ36TAVJUA FEATURES BENEFITS • External static pressure(ESP)capabilities up to 0.8"W.G. • DC fan motor provides improved efficiency • Three user selected fan speeds available plus fan"Auto" • Bottom access for easy service • Low ambient cooling operation down to 0"F(with optional wind baffle(s)) • Built-in condensate pump • Maximum piping length up to 230 ft.allows flexible placement of indoor unit • Maximum piping height separation up to 98 ft. • 10 year limited parts and compressor warranty INDOOR UNIT OUTDOOR UNIT 1111 1 ,t, It OP • Daikin North America LLC,5151 San Felipe,Suite 500,Houston,TX,77056 Daikin City Generated Submittal Data www.daikinac.com www.daikincomfort.com (Daildn's products are subject to continuous improvements.Daikin reserves the right to modify product design,specifications and information in this data sheet without notice and without incurring any obligations) Submittal Date:October 2021 Page 1 of 4 FDA/KIN Submittal Data Sheet 3.0-Ton DC Ducted Unit FBQ36PVJURZQ36TAVJUA SYSTEM PERFORMANCE Indoor Unit Model No. FBQ36PVJU Indoor Unit Name: Sky-Air DC Ducted Outdoor Unit Model No. RZQ36TAVJUA Outdoor Unit Name: Sky-Alr 3.0 Ton Heat Pump ODU Rated Cooling Capacity(Btu/hr): 36,000 Rated Cooling Conditions: Indoor(°F DB/WB):80/67 Ambient(°F DB/WB):95175 Sensible Capacity(Btulhr): 27,200 Rated Piping Length(ft): 25 Max/Min Cooling Capacity(Btulhr): / Rated Height Difference(ft): 0.00 Cooling Input Power(kW): 2.990 Rated Heating Conditions: Indoor(°F F DBAN): / / Ambient(°F DB/VJ6):47143 SEER(Non-Ducted/Ducted): /17.50 HSPF: /9.1 EER(Non-Ducted/Ducted): /11.10 Rated Heating Capacity(Btulhr): 40,000 SYSTEM DETAILS Refrigerant Type: R410A Cooling Operation Range(°F DB): 23-122 Holding Refrigerant Charge(Ibs): 7.9 Heating Operation Range(°F WB): 4-60 Additional Charge(Ib/fl): 0.04 Max.Pipe Length(Vertical)(ft): 98 Pre-charge Piping(Length)(ft): 15 Cooling Range w/Baffle('F DB): 0-122 Max.Pipe Length(Total)(ft): 230 Heating Range w/Baffle(°F WB): - Max Height Separation(Ind to Ind ft): 0 Daikin North America LLC,5151 San Fekpe,Suite 500,Houston,TX,77056 Daikin City Generated Submittal Data www.daikinac.com www.daikincomfort.com (Daikin's products are subject to continuous improvements.Daikin reserves the right to modify product design,specifications and information in this data sheet without notice and without incurring any obligations) Submittal Date:October 2021 Page 2 of 4 VDAIKIPJ Submittal Data Sheet 3.0-Ton DC Ducted Unit FBQ36PVJURZQ36TAVJUA INDOOR UNIT DETAILS Power Supply(V/Hz/Ph): 208-230/60 I 1 Airflow Rate(H/M/L)(CFM): 1130/953/812 Power Supply Connections: L1,L2,Ground Moisture Removal(Gal/hr): Min.Circuit Amps MCA(A): 2.9 Gas Pipe Connection(inch): 5/8 Max Overcurrent Protection(MOP)(A): 15 Liquid Pipe Connection(inch): 3/8 Dimensions(HxWxD)(in): 11-13/18 x 55-1/8 x 27-9/16 Condensate Connection(Inch): 1 Net Weight(lb): 102 Sound Pressure(H/M)(dBA): 43/41 Ext.Static Pressure(Rated/Max)(inWg): 0.8/0.8 Sound Power Level(dBA): 1-1/ts 24-13t6 Ductwork�'al: 46-47n61e1 4ulexuu Hteptnrdej' Supply Oprieg Realm Opening FBO3642PVJ1J Un lrut4l�� I' el W. - Nil doted Height j Width Sleight Width Nil Al..Id1 Unit(in.) G 1.....,,,,,.........„.„ f Fea16.4�vJu 45�6- r Fide-Hole Ceram) s1l:a.. !/ (Note:Opening dimension base on Fixing Cemx) Z ro A Im !mum'itch 1 ® CAM I) 17- 4N117- 4i1 irp 1_ ,. V WV 6Ax r a `,o _ a 8 Cagan lot la audet m ® w) Air inlet Iluettten hatth/6Ailn 1 / at 4 G ul Meet me ?) INlIT AS ME IA 11an IiE. A GCS / NIT ' to-t/16aaa a InlllCt M hat<h I _ \ a WE lydlT ;1:Tj: l 601 A � rrl- -Sa5-i - 5/I6 SI�TIF1YI61111E R'� \ m at nelnl In S ) 1 L H m (/, I e Q CeIIID6 i� 4 I—Ii'1////y\///).:; 46-5/8 !mondial and rl • I'�_o y�'����fff IIIN[lill kW L 128/01 tlOre'� 1 lit(CAW hatch T $1 me (knit)lettl� 6A!AS iK INCIA 11-1/1117-U1 at WI Z View eir size 0a le1AF1 ' 1 r'ta 8-7 31 T �-11 th De tie air outlet) Fi Air i11U p411 or lea 2a-1 16 It-6/rix -I. WI a # Ai;Dat14t-i� (NotC 21 (All art eld) ire n 1 . B IJ� i o .11 �lIIF rri =V _7._ lommumill Ceililg \Flair airfare IFroe the Air taut Dalain North America LLC,5151 San Felipe,Suite 500,Houston,TX,77056 Daikin City Generated Submittal Data www.daikinac.com www.daikincomfort.com (Daikin's products are subject to continuous improvements.Daikin reserves the right to modify product design,specifications and Information in this data sheet without notice and wilhout incurring any obligations) Submittal Date:October 2021 Page 3 of 4 VDAIKIN Submittal Data Sheet 3.0-Ton DC Ducted Unit FBQ36PVJURZQ36TAVJUA OUTDOOR UNIT DETAILS Power Supply(V/Hz/Ph): 208-230/60 11 Compressor Stage: Power Supply Connections: L1,L2,Ground Capacity Control Range(%): 14-100 Min.Circuit Amps MCA(A): 29.1 Airflow Rate(H)(CFM): 3741 Max Overcurrent ProtectIon(MOP)(A): 35 Gas Pipe Connection(inch): 5/8 Max Starting Current MSC(A): Liquid Pipe Connection(inch): 3/8 Rated Load Amps RLA(A): 19 Sound Pressure(H)(dBA): 57 Dimensions(IixWxD)(in): 52.15/16 x 35-7/16 x 12-5/8 Sound Power Level(dBA): Net Weight(lb): 225 o' o Rotator_anchor bolt bolt 1/2 UN0(4 pooitian)(4-M121- _ 2-13.'16(71) 5:8(16) -1 " Om 1 N aaR 1 .,....1......=2, .__........ I'I I 1-VI63:. - 4-7i16 - 18-9411W1) I/ 24-716E620) 5-I/ (113) NOTE 64S PIPE CONNECTICII IS IN THE 4SSESSOTY SET 1-316D0)_ I 85-7'16(800) 110e1D PEPE CWlsCTltsl IS THE SITE PR34EOE5 A' oo' _ 1■■11■■1 i -t '24ProarN2`:i1' Kira I1■■11■■1iI MI= 'IF.NM.2.1 ..,", Y 1■■11■■1 III,`41� ..�1a NN! F \,, SL :vaq a I 1■■11■■1 r O., Y/�/'- L.4-N i I .. 11■■11■■1 r — x > 11■■11■■1� iny-c 2 9V I I. 7 O= • r/7.� 11■■11■■1 N M i lY Nnr ,$'''. 1 T n� 1 4' 1 26 3 4 I3 1 8S_.0'6 S. 2-1,16(52) 3 tine) 4 3.4ti/ 2,1 rl (19) 5-11/16(145)_� n 1/2 OM 2-5.'6(67) 5-9/'16(142) Daikin North America LLC,5151 San Felipe,Suite 500,Houston,TX,77056 Daikin City Generated Submittal Data www.daikinac.corn www.daikincomfort.com (Daikin§products are subject to continuous improvements.Daikin reserves the right to modify product design,specifications and intonation in this data sheet without notice and without incurring any obligations) Submittal Date:October 2021 Page 4 of 4 DA /KIN Submittal Data Sheet 4.0-Ton DC Ducted Unit FBQ48PVJURZQ48TAVJUA FEATURES BENEFITS • External static pressure(ESP)capabilities up to 0.8"W.G. • DC fan motor provides improved efficiency • Three user selected fan speeds available plus fan"Auto"logic • Bottom access for easy service • Low ambient cooling operation down to 0`F(with optional wind baffle(s)) • Built-in condensate pump • Maximum piping length up to 230 ft.allows flexible placement of indoor unit • Maximum piping height separation up to 98 ft • 10 year limited parts and compressor warranty INDOOR UNIT OUTDOOR UNIT • • } r Ar ' i , 1 Daikin North America LLC,5151 San Felipe,Suite 500,Houston,TX,77056 Daikin City Generated Submittal Data www.daikinac.com www.daikjncomfort.com (Daiksis products are subject to continuous improvements.Daikin reserves the right to modify product design,specifications end information in this data sheet without notice and without incurring any obligations) Submittal Date:October 2021 Page 1 of 4 VD*IKIN Submittal Data Sheet 4.0-Ton DC Ducted Unit FBQ48PVJURZQ48TAVJUA SYSTEM PERFORMANCE Indoor Unit Model No. FBQ48PVJU Indoor Unit Name: Sky-Air DC Ducted Outdoor Unit Model No. RZQ48TAVJUA Outdoor Unit Name: Sky-Air 4.0 Ton Heat Pump ODU Rated Cooling Capacity(Btu/hr): 48,000 Rated Cooling Conditions: Indoor DB/WB):80/67 Ambientt(°F DB11N8):95!75 Sensible Capacity(Btu/hr): 36,100 Rated Piping Length(ft): 25 Max/Min Cooling Capacity(Btu/hr): / Rated Height Difference(ft): 0.00 Indoor(*F 70/ Goofing Input Power(kW): Rated Heating Conditions: Ambient(°F DB/WB):476 43 SEER(Non-Ducted/Ducted): /14.00 HSPF: /8.4 EER(Non-Ducted/Ducted): /8.60 Rated Heating Capacity(Btu/hr): 54,000 SYSTEM DETAILS Refrigerant Type: R-410A Cooling Operation Range('F DB): 23-122 Holding Refrigerant Charge(Ibs): 7.9 Heating Operation Range('F WB): -4-60 Additional Charge(Ib/ft): 0.04 Max.Pipe Length(Vertical)(ft): 98 Pre-charge Piping(Length)(ft): 15 Cooling Range w/Baffle(°F DB): 0-122 Max.Pipe Length(Total)(ft): 230 Heating Range w/Baffle('F WB): - Max Height Separation(Ind to Ind ft): 0 Daikin North America LLC,5151 San Feipe,Suite 500,Houston,TX,77056 Daikin City Generated Submittal Data www.daikinac.com www.daikincomfort.com (Daikin's products are subject to continuous improvements.Daikin reserves the right to modify product design,specifications and information in this data sheet without notice and without incurring any obligations) Submittal Date:October 2021 Page 2 of 4 VDAIKIN Submittal Data Sheet 4.0-Ton DC Ducted Unit FBQ48PVJURZQ48TAVJUA INDOOR UNIT DETAILS Power Supply(V/Hz/Ph): 208-230/60/1 Airflow Rate(H/M/L)(CFM): 1400/1,165/988 Power Supply Connections: L1,L2,Ground Moisture Removal(GaVhr): Min.Circuit Amps MCA(A): 3.4 Gas Pipe Connection(inch): 5/8 Max Overcurrent Protection(MOP)(A): 15 Liquid Pipe Connection(inch): 3/8 Dimensions(HxWxD)(in): 11-13/16 x 55-1/8 x 27-9/16 Condensate Connection(inch): 1 Net Weight(lb): 102 Sound Pressure(H/M/L)(dBA): 44/42/40 Ext.Static Pressure(Rated/Max)(inWg): 0.4/0.8 Sound Power Level(dBA): FBQ36-48PVJU 41 trial re,'. 1116,]r. _ 24-Ia.it:81n d 03'4(54 TAo4 :arl P.anm • 1,- M 01bait 6tlm ��- '• 1, Vr- A t t^rm1Nn pw ed?me 6 \ Fse Act pill neat' �- _ `.ar0 ne14nte Nrta Unit in. fte) 1 $ all rta.oes2f4 to me le sere ce In the space r I� cotter Lk kW,mambo, I i i I�i_)l R R_ 'etch P l amens»r I fed,r $ +. II; 1/ I ffi a t' I _ C ,,l to. • ik�[e{axe P.1�<; k� MIN AS n£noou 1" t t wrt.ol m. d I / \ _ Air inlet eel iliF OR SAE' «t a e- 1 �`---�J 9 25165, PG-516%1:21atIP;oDIm[Mle WI 1 e y a -� A 1 re.4 Tom _-. :int R @ 3 �Ia t-{—. __ lalemt m n tAr al'rrr- l 1 r Mt&lk d 4 _ 4_,_ lmw .A to i c aiMZ- _1 5. PgI„ 11f51a 41 5 I6'n150.1fa01Is'16 I ..6,I« - 45-11 16i1100: CO) II d 4lr4I1-d!in o ` I,I` I.b _ 4, IGrte bit A r lot tell -.- •. CAR LA: k r, Flit ee �. B1.4 feet l hoe f\x ar,scogner ^ va ``� I ne[w 3 it n a-y LZ. __ Z Viet Rr ,e ai11i®aYnMY I ue VJ�/1i /I �/, j t Inp flac rat 1' / ) I pact.r As s vnata �✓ v 1 ]iil.3.eere ]ASalaF4 &a ___ �'K I-+ i!'U w_u: c. Pni n nm 1 orn sn•,Mh6]/�.dJ.l (�'i IL \ r41M1[YAIM1Ce spate Was nil eacq w nn n+e r l axeoflas Jrli SIJCAge'. Y.ae&r Vim E-] r i Air inlet 'Ii _ 22' MI 2.3112:44 endAeb i sg 9 6-e le El itbte 21 w- 1 ]I-I IB']aa: AI --- _ i c Air outlet ..•"e 1 ' ' -gr: �1' ArilZ ---'1 rh(b.. 1 Aa+ 1 5. 57 .. -j 3D065879J d - ��1( (i�4' i i g u . _ eu 1 ea,.r;41eA16xlxaol r T i. - 21-9'14000/ q 1 g a d,.e SE-ans.1P]sl sa oA nasm - Ceding / I'/Cfltp surface :°nn Ire A r In et Daikin North America LLC,5151 San Felipe,Suite 500,Houston,TX,77056 Daikin City Generated Submittal Data www.daikinac.com www.daikincomfort.com (Daikin's products are subject to continuous improvements.Daikin reserves the right to modify product design,specifications and information in this data sheet without notice and without incurring any obligations) Submittal Date:October 2021 Page 3 of 4 , . VDAIKIN Submittal Data Sheet 4.0-Ton DC Ducted Unit FBQ48PVJURZQ48TAVJUA OUTDOOR UNIT DETAILS Power Supply(V/Hz/Ph): 208-230/60 I 1 Compressor Stage: Power Supply Connections: L1,L2,Ground Capacity Control Range(%): 14-100 Min.Circuit Amps MCA(A): 29.1 Airflow Rate(H)(CFM): 3471 Max O ereurrent Protection(MOP)(A): 35 Gas Pipe Connection(inch): 5/8 Max Starting Current MSC(A): Liquid Pipe Connection(Inch): 3/8 Rated Load Amps RLA(A): 19 Sound Pressure(H)(dBA): 57 Dimensions(HxWxD)(in): 52-15/16 x 35-7/16 x 12-5/8 Sound Power Level(dBA): Net Weight(lb): 225 Hole for anchor bolt 7I bon 1,211/NC(4position9X4-M12)- `i 2-13-'15(711.,_ . 5.1806) m , SrN e gg I — 'i.W '.4 . II', -1! 24-7-10(620/ 5-V (r'3. n 40/ ' ffia Volt ,n.•,1) NOTE- Limo PIPE CONNECTION ION IS S r9HE SITE PR3PEOES _ 1-3-t8(JO) y5-N I6(900) I ==I 11■■11■■11 -� 11■■il■■I ;tiA. II■■11■■ ! �� r, 11■■11■■1 Ilp, d��i bc .�°; 11■■11■■II I7� z '. �1■■1'1■■I ' p I 9 l ; �s� ;_, " a 111■■11■■I '�.�y}=.: I■■11■■1I a ia_- �� Lb -1 ^l \�d$ii ;syNH)Y�/. n i m ..__......_._ e 11■■11■■I,, [1 i}� - a.z=_ >'-- '�`" m ` .q III■■1I1■■1 1 1 I' ■EN — III t.�...... .., , - 3 III � n. i nI M 3/4 3-1' 60 -: T_I_t_6(52 i n 19. 5-I I/16045) ' co 1/2 1.2-5/8(67) 1/2 99) 4, 3"41191 _n r A) 6-9/16(142) Dalkin North America LLC,5151 San Felipe,Suite 500,Houston,TX,77056 Daikin City Generated Submittal Data www.daikinac.com www.daikincomfort.com (Daikin's products are subject to continuous improvements.Dadtin reserves the right to modify product design,specifications and information in this data sheet without notice and without incurring any obligations) Submittal Date:October 2021 Page 4 of 4 • VDAIKIN Submittal Data Sheet 1 Ton LV Wall Mount-FTXS12LVJU Project:Hunter Davisson-Dartmouth Crossing Submitted by:Heather Giltner of AIR REPS LLC on 5/26/2023 Submitted to:No Engineer Name Specified Tags:FCU-9,FCU-10 FEATURES • IR controller included • 3-D airflow-Auto-swing(up,down and right,left) • Intelligent eye occupancy sensor • Titanium apatite photocatalytic air purifying • Hot start technology • Auto-restart(after power failure) BENEFITS • 12 year limited parts and compressor warranty with online registration • 5 Year limited parts warranty for commercial applications Delkin North America LLC,19001 Kenner Rd,Wetiar,TX 77484 Daikin City Generated Submittal Data www.daikinoo com www.daikincnmfncom (Deikin's products are subject to continuous improvements.Daikin reserves the right to modify product design,specifications and information in this data sheet without notice and without inclining any obigalions) Submittal Date:5/262023 1:20:21 PM Page 1 of3 '`jrDA I KIN Submittal Data Sheet 1 Ton LV Wall Mount-FTXS12LVJU Project:Hunter Davisson-Dartmouth Crossing Submitted by:Heather Gi tner of AIR REPS LLC on 5/26/2023 Submitted to:No Engineer Name Specified Tags:FCU-9,FCU-10 PERFORMANCE Indoor Unit Model No. FTXS12LVJU Indoor Unit Name: 1 Ton LV Wall Mount .. _........... Indoor(°F DB/WB):80/67 Type: Wall Mounted Rated Cooling Conditions: Ambient(°F DBNYB):95/75 Rated HeatingConditions: Indoor(°F DB/WB):70/60 Rated Cooling Capacity(Btu/hr): Ambient(F DB/WB):47/43 Sensible Capacity(Btu/hr): Rated Piping Length(ft): 25 Cooling Input Power(kW): Rated Height Separation(ft): 0 INDOOR UNIT DETAILS Power Supply(V/Hz/Ph): 208-230/60/1 Airflow Rate(H/M/USL)(CFM): 4031307/205/155 Power Supply Connections: See Outdoor Unit for Electrical Specs Moisture Removal(Gal/hr): 0.3 Min.Circuit Amps MCA(A): Gas Pipe Connection(inch): 3/8 Max Overcurrent Protection(MOP) Liquid Pipe Connection(inch): 1/4 (A): Dimensions(HxWxD)(in): 11-5/8 x 31-1/2 x 8-7/16 Condensate Connection(inch): 5/8 Net Weight(lb): 22 Sound Pressure(H/MIUSL)(dBA): 45/37/29/23 Ext.Static Pressure(Rated/Max) 0/0 Sound Power Level(dBA): 57 (inWg): Daikin North America LLC,19001 Kermier Rd,Wager,TX 774e4 .w.muree.mm e.waarrcomio4 coin 081k1n City Generated Submittal Data (Daikin's products are subject to continuous improvements.Daikin reserves the right to modify product design.specifications end information in this Pala sheet without notice and without incurring any oblgations) Paget of Submittal Date:5/26/2023 1:20:21 PM VDAIKIN Submittal Data Sheet 1 Ton LV Wall Mount-FTXSI2LVJU Project:Hunter Davisson-Dartmouth Crossing Submitted by:Heather Giltner of AIR REPS LLC on 5/26/2023 Submitted to:No Engineer Name Specified Tags:FCU-9,FCU-10 DIMENSIONAL DRAWING FTTXS09,12LVJU THE MARK(°)SHOWS PIPING DIRECTION C> AIRFLOW(INDOOR)j 31-1/2(S00mm) I ' REAR rI w I l M O LEFT _ — RIB (INCLUDING \ E¢ MOUNTIING PLATE) O LL¢ 89/16(217mm) w �g ., , 84(16(215mm) 1-15/16(50mm)MINT ii /� (� N a (SPACE FOR v 1-15116(50mm)MIN C MAINTENANCE) REQUIRED SPACE (SPACE FOR MAINTENANCE) Ilh��� FRONTGRILLE E . NAME PLATE a FIXED SCREWS E ONSIDE) TERMINAL BLOCK WITH GROUND TERMINAL ailm=•-•Ci BOTTOM+ / INTELLIGENT EYE SENSOR I— • LOUVERS SIGNAL RECEIVER ` OPERATION LAMP GAS PIPE 43/8(49.5mm)CUT ABOUT 13-TIMER LAMP (THE LENGTH OF PIPE OUTSIDE DRAIN HOSE . '—L='^ THE UNIP: 3/4(350mM)) (CONNECTING PART .61 INTELLIGENT EYE LAMP O.D.4518(416rnm) INDOOR UMT ON/OFF SWITCH UOUID PIPE 41/4(46.4mm)CuT THE HOSE LENGTH OF OUTSIDE E (THE LENGTH OF PIPE OUTSIDE THE UNIT IS APPROX.18-5/16(465mm)) ROOM TEMP.THERMISTOR(INSIDE) ATHE UNR:ABOUT 15.3/4(400mm))311/2(800mm) MODEL NAME PLATE 23-1/16(566mm) ---SIGNAL TRANSMITTER LADE ANGLES `r. 5-3l4(115.5mm 25/16(5B 18 mm) 11/16 mm) UP/DOWN H \ a l T (AUTOMATIC) �,__r ^ —^ COOLING,DRY HEATING FANo _ _ / EE n,� , < C) M1 Boo 1$° ° OO//�J,�/ 5° O ` O, N \./ 30° 3a S Lf 45° 56° 65° 65° _ __ ,i_ 4 A 70° 80° L.q�WALL HOLE FOR WALL HOLE r I RIGHTILEFT 2.9/B(601nrn)J EMBEDDED PIPING 029/18(465mmIHOLEJL 2-5/16(59.5mm) t— (AUTOMATIC) 6(465mm)HOLE WIRELESS REMOTE CONTROLLER STANDARD LOCATIONS OF WALL HOLES (ARC452A21) Daikin North America LLC,19001 Keanier Rd,Waller,TX 77484 Daikin City Generated Submittal Data w...daainacmm w-..deikinmmrnrt ram (Daikiri s products are subject to continuous Improvements.Daikin reserves The tight to modify product design,specifications and information in this data sheet without notice and without incurring any ablgahons) Submittal Dale:5/26/2023 1:20.21 PM Page 3 of DA/KIN Submittal Data Sheet 2.0-Ton,3-Port Heat Pump,Ductless ODU 3MXS24WMVJU9 FEATURES • High-efficiency inverter driven swing compressor BENEFITS • • • 12 Year limited parts warranty with online registration • • • __ kr Daikin North America LLC,19001 Kenner Rd,Waier,TX 77484 Daikin City Generated Submittal Data www.da,k.ac.com ww.dalkincomrortcorn (Daikin's products are subject to continuous improvements.Daikin reserves the right to modify product design,specifications and information in this data sheet without notice and without incurring any obigations) Submittal Date'5/2812023 128.09 PM Page 1 of 4 VDAIKIN Submittal Data Sheet 2.0-Ton,3-Port Heat Pump,Ductless ODU 3MXS24WMVJU9 EFFICIENY PERFORMANCE SEER EER HSPF COP COOLING: HEATING: Non-Ducted: Rated(Btu/hr): Rated(Btulhr): Ducted: Operating 14°F-115°F Operating 5°F-60°F Range: Range: Mixed: 0 0 0 0 Rated Cooling Conditions: Rated Heating Conditions: Indoor(°F DB/DB):80/67 Indoor(°F DB/WB):70/60 Ambient(°F DB/WB):95/75 Ambient(°F DB/WB):47/43 ELECTRICAL PIPING Power Supply(V/Hz1Ph): •208-230/6011 Max.System Piping Length: 230 Gas Conn. 3/8 °See Engineering Manuals for other voltages. (feet): (inch): System MCA: 18 1 Max.Interunit Piping New Liquid Conn. 1/4 (Min.circuit amps) Length:(feet): Attribute (inch): System MFA: 25 0 Max.Height Difference 49 25 Drain Conn. (Max.fuse amps) IDU to ODU(feet): (inch): Compressor RLA: 15.5 Max.Height Difference (Rated load amps) IDU to IDU(feet): 82 Outdoor fan motor FLA: 0 3 Refrigerant Pre-Charged 1312 (Full load amps) Pipe Length(ft): Outdoor fan motor W: FanMotorOutput7 (Rated output watts) SPECIFICATIONS Compressor Type: Swing Compressor Stage: Inverter Refrigerant Type: Refrigerant Oil: PVE(FVC50K) Factory Charge(Lbs): 6.17 Additional Refrigerant Charge 0.21 (Ozs/ft): COOLING-Airflow Rate(cfm): HEATING-Airflow Rate(cfm). High: 2,094 High: 2,094 Med: Med: Low: Low: Sound Level(dBA): 52 Sound Level(dBA): 54 Dimensions(HxWxD)(in): 28-15/16 x 34-1/4 x 12-5/8 Net Weight(lb): 140 Daikin North America LLC,19001 Kenner Rd,Waller,1X 77484 Daikin City Generated Submittal Data wwr.daienac.mm w..w.eahancumtort.com (Dalkin's products are subject to continuous improvements.Daikin reserves Ike right to modify product design,specrficalions and information in this data sheet without notice and without incurring any oblgetions) Submittal Dale.5/28/2023 1:28:09 PM Page 2014 VDAIKIN Submittal Data Sheet 2.0-Ton,3-Port Heat Pump,Ductless ODU 3MXS24WMVJU9 DIMENSIONAL DRAWING 151 Daikin North America LLC,19001 Kenner Rd,Waller,TX 77484 Dentin City Generated Submittal Data www.daitinac.mm www.daibncomtort.com (Daikin s products are subject to continuous improvements.Daikin reserves the right to modify product design,specifications and information In this data sheet without notice and without incurring any obligations) Submittal Date:5/26120231:28:09 PM Page 3 of 4 DAIKIN Submittal Data Sheet 2.0-Ton,3-Port Heat Pump,Ductless ODU 3MXS24WMVJU9 OPTIONAL ACCESSORIES INCLUDED PART DESCRIPTION NUMBER No DACA-WB-3 Powder-Coated Wall-Mounted Bracket No KEH063A4EA BmI LRg Drain Pan Heater Rev A No KKG063A42 Back protection wire net No KKG063A43 Side protection wire net(18&24) No KPS063A41 Snow hood(intake side plate)(15,18&24) No KPS063A44 Snow hood(intake rear plate)(15,18&24) No KPS063A47 Snow hood(outlet)(15,18&24) No KPW063B4 Air direction adjustment grille No RAQAHLGD1 Rear Coil Guard BML Daikin North America LLC,19001 Kermier Rd,Waller,TX 77484 Daikin City Generated Submittal Data www.oaiemao,com wwwea w,ramfoe.com (Daikin's products are subject to continuous improvements.Daikin reserves the right to modify product design,specifications and information in this data sheet without notice and without incurring any obigations) Submittal Date.5/282023 1:28:09 PM Page 4 of 4 VDAIKIN Submittal Data Sheet BRC944B2-A08 -Wired Remote Controller Kit Project Name: Location: Approval: Engineer: Date: Submitted to: Construction: Submitted by: Unit* Reference: Drawing #: MODEL COMPATIBILITY: Compatible with Single-Zone and Multi-Zone indoor unit models: CDXS, CTXS, FDXS, FTK_N, FTK_A, FTX_N, FTX_A, FTX_U, FTXG*, FTXR, FTXS, FVXS *The Sarara drying function of the QUATERNITY units is not supported with the 8RC944. The following indoor units do not have the S21 connection and require an additional interface adaptor(ordered separately)to provide the S21 connector for the One+ communication: Indoor Unit Models Required Interface Adaptor FTX09NMVJU, FTX12NMVJU FTKO9NMVJU, FTK12NMVJU KRP067A41E FTX15NMVJU, FTX18NMVJU, FTX24NMVJU, FTKI8NMVJU, FTK24NMVJU KRP980B2E SPECIFICATIONS: PRODUCT IMAGE: Model BRC944B2-A08 Description Wired Remote Controller Kit' 11,111 oM-oFF 7r)JIR'IA. Maximum Indoor Units 1 0uEUMeDAUtt1MEROEI ; 4.75inx4.75inx0.69in 88_88 Dimensions (120mm x 120mm x 17.5 mm) .88,-81 — Communication , Protocol S21 i ( I i Comfort Setpoint Range 64°F—90°F Set Point Range SET Srt.TEMP ,,c i 1 Start/Stop Tlttfn Mode(Auto/Heat/Cool/Dry) Operation Set Temperature Setpoint BRC944B2 Fan Speed Airflow Direction (� One-time Timer t� ~ Scheduling '" Daily Timer BRCW901A08 1The Wired Remote Controller kit includes a Wired Remote Controller(BRC944B2)and a wired remote controller cable (BRCW901 A08) DAIKIN COMFORT TECHNOLOGIES NORTH AMERICA,INC. 19001 Kermier Road I Waller,TX,77484 Rev.1022 www.daikinac.com www.daikincity.com (Daikin's products are subject to continuous improvements. Daikin reserves the right to modify product design,specifications and information in this data sheet without notice and without incurring any obligations) Page 1 of 2 VDAIKIN Submittal Data Sheet BRC944B2-A08 —Wired Remote Controller Kit Project Name: Location: Approval: Engineer: Date: Submitted to: Construction: Submitted by: Unit#: Reference: Drawing #: FEATURES: • Selectable auto/cool/heat/dry operation modes with adjustable setpoint and fan speed • Set temperature setpoint in °F or°C units with 1 degree increments • Temperature is controlled through indoor unit temperature sensor • Built in one time or daily timer functionality with up to 2 timer actions per day • Approximately two-hour battery backup • Can be used together with the factory supplied standard wireless remote controller • An additional or replacement wired remote controller cable can be ordered: o BRCW901A03: Non-plenum rated, 10ft o BRCW901A08: Non-plenum rated, 26ft o DACA-BRCW901 P10: Plenum rated, 10ft o DACA-BRCW901 P25: Plenum rated, 25ft DIMENSIONS: ,_ 7e) viil__�_ se 1 CORO OUTLET HOLE .'1 11/16 7/8 1111 1-1/8 11/16 INN DOCUMENTATION: Documentation available on www.daikincitv.com and/or www.daikinac.com: • Submittal • Installation Manual • Operation Manual GAMIN COMFORT TECHNOLOGIES NORTH AMERICA,INC. 19001 Kermier Road I Waller,TX,77484 Rev.1022 www.daikinac.com www.daikincitv.com (Daikin's products are subject to continuous improvements. Dalkin reserves the right to modify product design,specifications and information in this data sheetwghout notice and without incurring any obligations) Page 2 of 2 VDAIKIN Submittal Data Sheet BRC1 E73 — Navigation Remote Controller Project Name: Location: Approval: Engineer: Date: Submitted to: Construction: Submitted by: Unit#: Reference: Drawing #: MODEL COMPATIBILITY: Compatible with VRV and VRV LifeTM indoor unit models: FXAQ FXDQ FXEQ FXFQ, FXHQ FXLQ FXMQ FXMQ_MF, FXNQ FXSQ FXTQ FXUQ FXZQ VAM, CXTQ Compatible with SkyAir indoor unit models: FAQ FBQ FCQ FHQ FTQ Compatible with Single and Multi-zone system indoor unit model: FFQ FDMQ SPECIFICATIONS: PRODUCT IMAGE: Model BRC1 E73 Proa,rara Description Navigation Remote Controller Cool * 9:004 Maximum Connections 16 indoor units tkosi t to 18AWG-2, No polarity •'� 74 r�> 75' Communication Wire NI' Stranded, Non-shielded Total Wiring Length 1,640 ft. (500 m) Communication Daikin proprietary P1P2 protocol Protocol v,:n7rc (jei Lili Power 16VDC supplied by indoor unit (1.58VAmaximum) ft`'"11 Comfort Setpoint Range 60 to 90 °F (16 to 32 °C) Setback Setpoint Range 40 to 95 °F (5 to 35°C) \ T ,I Carl.•,i Operating Temp Range 14 to 122°F(-10 to 50°C) Operating Humidity75%or less(RH) Notes: P 9 (1) 1 of 3 display options-Detailed Range (without condensation) display shown Dimensions(WxHxD) 4.72x4.72x0.75 inch (120x120x19 mm) Weight(Mass) 0.42 lbs.(0.19 kg) FEATURES: 1. Up to 16 indoor units are controllable within one group 2. Within one group, up to 2 Navigation Remote Controllers can be used, one as a main and one as a sub 3. Backlit LCD displays in English, Spanish or French 4. Temperature sensor built-in with configurable offset 5. Display of Temperature and Setpoint in 1°F/°C increments 6. Three configurable display options: Detailed, Standard and Simple 7. Dual setpoints (independent cooling and heating setpoints)with configurable minimum setpoint differential or Single Setpoint(occupied period) 8. Setpoint range limit for cooling and heating modes Daikin North America LLC,5151 San Felipe,Suite 500, Houston TX,77056 www.daikinac.com www.daikincity.com (Daikin's products are subject to continuous improvements. Daikin reserves the right to modify product design,speatications and information in this data sheet without notice and without incurring any obligations) Page 1 of 4 VDAIKIN Submittal Data Sheet BRC1 E73 — Navigation Remote Controller Project Name: Location: Approval: Engineer: Date: Submitted to: Construction: Submitted by: Unit#: Reference: Drawing #: 9. Independent cooling and heating setback setpoints (unoccupied period) 10. Auto changeover control with configurable primary and secondary changeover dead bands and guard timer 11. Airflow— Individual air flow direction, dual airflow and auto draft prevention (prevents air blowing directly on occupants)* 12. Built-in 7 days, weekdays+weekend, weekdays+Sat+Sun, and Everyday schedules with up to 5 actions per day with independent cooling and heating or setback setpoints 13. Automatic Setback by occupancy sensor* 14. Automatic Off by occupancy sensor* 15. Configuration for Self-cleaning filter panel** 16. Automatic adjustment for Daylight Savings Time (DST) 17. 48 hour clock/calendar battery backup (protects schedule timing in cases of short term power loss from indoor unit) 18. Real-time monitoring of system malfunctions with immediate display of unit in error and error code 19. The buttons on the remote controller are selectable by locking out the unwanted buttons 20. The operation modes can be restricted to provide only the desired mode(s) of operation 21. Display can be configured to show"Off' and room temperature only when indoor unit is turned off 22. To prevent unwanted changes, fan speed selection and display may be hidden 23. Auto off timer configurable in 10 minute increments (range 30-180 minutes) 24. Can be used to replace earlier versions of remote controllers *Available for FXFQ_TVJU, FXUQ_PVJU, and FXZQ_TA indoor units **Available for FXFQ_TVJU indoor units SYSTEM DIAGRAM: DIl l-Net P1P2 /up to 16 I indoor units — Main Sub Multiple indoor units Stand-alone 2 controllers used for group control group control single group control FACE DECAL OPTIONS: Face decal options are used to hide unnecessary buttons: 1. The face decal is designed to adhere to the faceplate 2. Hidden buttons can be accessed by service personnel without removing the face decal due to its flexibility Daikin North America LLC,5151 San Felipe,Suite 500,Houston TX,77056 www.daikinac.com www.daikincity.com (Daikin's products are subject to continuous improvements. Daikin reserves the right to modify product design.specifications and information in this data sheet without notice and without incurring any obligations) Page 2 of 4 r'DAIKIN Submittal Data Sheet BRC1 E73 — Navigation Remote Controller Project Name: Location: Approval: Engineer: Date: Submitted to: Construction: Submitted by: Unit#: Reference: Drawing #: 71 71. Used with Single Setpoint mode Dual Setpoint mode BRC1E72RM 8RC1E72RF BRC1E72RMF BRC1E72RM2 BRC1E72R02 13RC1E72RMF2 Model • • • On/Oft X X x X X X Mode X X X X Fan X X X X Up,Down X X X X X X Left,Right X X X Menu/Ok Cancel DIMENSIONS: , PhIAMP 4-3/4" 4-3/4" - %uo DOCUMENTATION: Documentation available on www.daikincity.com and/or www.daikinac.com: • Installation Manual • Operation Manual Daikin North America LLC,5151 San Felipe,Suite 500,Houston TX,77056 www.daikinac.com www.daikincity.com (Daikin's products are subject to continuous improvements. Daikin reserves the right to modify product design,specifications and information in this data sheet without notice and without incurring any obigations) Page 3 of 4 VDAIKIN Submittal Data Sheet BRC1 E73 - Navigation Remote Controller Project Name: Location: Approval: Engineer: Date: Submitted to: Construction: Submitted by: Unit#: Reference: Drawing #: • Submittal • Guide Specifications • Quick User Guide • Field Setting Table Daikin North America LLC,5151 San Felipe,Suite 500, Houston TX,77056 www.daikinac.com www_daikincitv.com (Daikin's products are subject to continuous improvements. Daikin reserves the right to modify product design,specifications and information in this data sheet without notice and without incurring any obligations) Page 4 of 4 • 1 SUBMITTAL Job Name: Dartmouth Crossing RECEIVED Engineer: Hunter Davisson JUN 2 0 2023 Elevation: (ft) 108 CITY OF TIGARD Date: 5/26/2023 BUILDING DIVISION Submitted By: Douglas Smith JOHNSON AIR PRODUCTS 2220 SE 9TH AVE PO BOX 15098 PORTLAND, OR 97214 US Phone: (503)234-5071 Fax: (503)233-0451 Email Address: kharrah@johnsonair.com aGREENHECK Building Value in Air. P.O. Box 410 Schofield, WI 54476 (715)359-6171 FAX (715) 355-2399 www.greenheck.com G:\KevinHarrah\Secured 2023100-F\Dartmouth Crossing.gfcj CAPS 4.41.1100 Generated by:kharrah@johnsonair.com Page 1 of 11 r Printed Date: 05/26/2023 GREENHECK Job: Dartmouth Crossing El Building Value in Air. Mark: EF-1 Model: CUE-090-VG Model: CUE-090-VG Direct Drive Upblast Centrifugal Wall Exhaust i — -- f 1 i Fan 19.00 SO 0 27.25 Di _ ensional I ��m 1 Quantity 1 I — f1.75 Weight w/o Acc's(Ib) 31 WALL Weight w/Acc's(Ib) 36 -- 11.50 Weight w/Acc's and Curb(Ib) 72 Standard Curb Cap Size(in.) 19 x 19 —(18.00)-- 13.38 --- Wall Opening with Curb(in.) 19 x 19 through wall 31.38 OVERALL HEIGHT MAY BE GREATER DEPENDING ON MOTOR,ADAPTER,AND/OR HINGE BASE. Performance Requested Volume(CFM) 600 1'0 _ 0.5 600 Total Externalu )wg) 'SP(in. 0.5 0.8 1659 FRAM 0.4 Fan RPM 1659 Operating Power(hp) 0.1 Elevation(ft) 108 cm Airstream Temp.(F) 70 0 6 0.3 n co Air Density(Ib/ft3) 0.075 m m y — 3 Tip Speed(ft/min) 4,725 co3 0 2 0.4 1 0.2 a Static Eff.(%) 45 0_ - y a.) U 4' 6 t 70 Misc Fan Data ( 0.2 `m_ ----- --------A-- Fan Eff.Index(FEI) - ° -_• -_ - --__ Outlet Velocity(ft/min) 857 ---- Qo Sys---. 0.0 1- - • T I I III I I 11 III 0.0 Motor 0 1 2 3 4 5 6 7 8 9 Motor Mounted 1 Yes Volume(CFM)x 100 Size(hp) 1/6 Voltage/Cycle/Phase 115/60/1 - Operating Bhp point Enclosure I TENV 0 Operating point at Total External SP Fan curve Motor RPM 1725 - - - -System curve Efficiency Rating , High Brake horsepower curve Windings 1 FLA(Amps) 2.2 Min.Circuit Ampacity(MCA) 3 Notes: All dimensions shown are in units of in. Max.Overcurrent Protection(MOP) 15 'NEC FLA,MCA and MOP are for reference only-based on Short Circuit Current Rtg(SCCR) 5 kA tables 430.248 or 430.25 of National Electric Code 2020.Actual motor FLA may vary,for sizing thermal overload,consult factory. t:Q MCA and MOP values shown only account for the motor,not Qm IRORIDWIDE Ia accessories(damper actuator,field supplied VFD,etc). 01R11Me Sound Power byOctave Band LwA-A weighted sound power level,based on ANSI 51.4 MAGI dBA-A weighted sound pressure level,based on 11.5 dB �ww Sound attenuation per Octave band at 5 ft-dBA levels are not licensed p Data 62.5 125 250 500 1000 2000 4000 8000 LwA dBA Sones by AMCA lnlern�using ANSI/AMCA 301 at 5 ftrIM= sr Inlet 75 74 71 64 60 57 54 47 67 56 8.3 G:\KevinHarrah\Secured 2023100-F\Dartmouth Crossing.gfcj CAPS 4.41.1100 Generated by:kharrah@johnsonair.com Page 2 of 11 0GREENHECK Printed Date: 05/26/2023 Job: Dartmouth Crossing Building Value in Air. Mark: EF-1 Model: CUE-090-VG Model: CUE-090-VG Direct Drive Upblast Centrifugal Wall Exhaust Fan Standard Construction Features: -Aluminum housing-Backward curved composite(sizes 60-95)or aluminum (sizes 99-300)wheel-Aluminum curb cap with prepunched mounting holes- Drain trough-Ball bearing motors(sizes 85-300 and all Vari Green),sleeve bearing motors(sizes 60-80)-Motor isolated on shock mounts-Corrosion resistant fasteners Selected Options &Accessories: Motor-Vari-Green EC motor Control-Dial for balancing Standard Curb Cap Size-19 Square Sidewall Mounting-Fan Configured for Wall-Mounted Applications Curb will be Through Wall, 10 in.Wall Thickness UL/cUL 705 Listed-"Power Ventilators" Switch,NEMA-1,Toggle, Shipped with Unit Junction Box Mounted&Wired Foam Curb Seal(Factory Applied) Birdscreen:Stainless Steel,nom.89% Free Area Composite Wheel Material Unit Warranty: 1 Yr(Standard) Selected Sub Marks See individual submittals for full details GPF-19-G18 The Vari-Green Motor included in this order has a'Multi-Voltage'ability. The red wire on the motor is called a'Voltage Doubler',and when it is connected the motor can be powered by 115V. If the Red wire is disconnected,then the motor can be powered with 208-230/277V. The motor will leave the factory with the voltage doubler wired per the order. G:\KevinHarrah\Secured 2023100-F\Dartmouth Crossing.gfcj CAPS 4.41.1100 Generated by:kharrah@johnsonair.com Page 3 of 11 L-151GREENHECK Printed Date: 05/26/2023 Job: Dartmouth Crossing Building Value in Air. Mark: EF-1 Model: CUE-090-VG Vari-Green Motor & Control Options An EC motor that uses AC input power and internally converts it to DC power. Potentiometer (dial) mounted on the motor enclosure adjusts the speed (RPM) down 80%. Vari-Green motors feature a soft-start and inherent thermal and current protection built into each unit. Inrush current at start up is eliminated and the motor will automatically reduce speed or turn off if overloaded or it becomes too hot. Motor Configuration POWER INPUT Input Voltage: 115 ( WHITE BLACK 115 VAC NEUTRAL Speed Reference: Dial on Motor �. GREEN GROUND Permanent Dial: Yes SPEED CONTROL /J Control Configuration ;CD;— Control Type: N/A Transformer: None VAR/��GREEN Max VREG Max VOLTAGE JUMPER CLOSED OMWINGj 1.6.1.v1 G:\KevinHarrah\Secured 2023\00-RDartmouth Crossing.gfcj CAPS 4.41.1100 Generated by:kharrah@johnsonair.com Page 4 of 11 LJGREEAIHECK Printed Date: 05/26/2023 Job: Dartmouth Crossing Budding Value in Air. Mark: EF-1 Model: GPF-19-G18 �s.5o 18.50� Model: GPF 1441114444 Roof Curb 1s.00 Standard Construction Features: -Roof Curb fits between the building roof and the fan mounted directly to the roof support structure -Constructed of either 18 ga galvanized steel or 0.064 in. aluminum-Straight Sided without a cant-2 in.or 5 in.mounting flange-1 in. thick 3 lb density insulation-Height-Available from 8 in.to 42 in.as specified in 0.5 in.increments. Notes:-The maximum roof opening dimension should not be greater than the"Actual"top outside dimension minus 2 in.. -The minimum roof opening dimension should be at least 2.5 in. more than the damper dimension or recommended duct size.-The Roof Opening Dimension may or may not be the 28.50 28.50 same as the Structural Opening Dimension.-Damper Tray is optional and must be specified. Tray size is same as damper size.-Security bars are optional and must be specified. Frames and grldwork are all 12 ga steel. Gridwork is welded to the frame and the frame is welded to the curb. ***This curb can be mounted on the roof or wall(with a sidewall mounted CUE or CUBE fan). General Sizing Undersizing Weight Shipped Tag Qty Model Method (In.) (lb) Assembled Union Label No 1 1 GPF-19 Nominal 0.5 35 Yes f preference Dimensions Nominal Nominal Actual Actual Actual Actual Hinge Hinge Curb Outside Outside Outside Outside ', Inside Inside Flange Flange Base Base Height Width Length Width Length Width Length Width Length Width* Length* , (in.) (In.) (In.) (in.) (in.) (in.) (in.) (in.) (in.) (in.) (in.) 18 19 19 18.5 I 18.5 15 15 28.5 28.5 18 18 *May not be applicable Accessories Security 1 insulation insulation Material Bars Liner (In.) R Value I Galvanized No No 1 R4.3 1 G:\KevinHarrah\Secured 2023\00-F\Dartmouth Crossing.gfcj CAPS 4.41.1100 Generated by:kharrah@johnsonair.com Page 5 of 11 Printed Date: 05/26/2023 • ®GREENHECK Job: Dartmouth Crossing ® Building Value in Air. Mark: EF-2 Model: G-100-VG - -0 24.40 _- Model: G-100-VG Direct Drive Centrifugal Roof Exhaust Fan Previously: G-103-VG — 23.70 Dimensional 35.70 Quantity 1 p1.75 Weight w/o Ace's(Ib) 36 r Weight w/Acc's(Ib) 41 (12.00) Weight w/Ace's and Curb(Ib) ' 57 Standard Curb Cap Size(in.) 19 x 19 Roof Opening(in.) 15.5 x 15.5 —19.00 SO— OVERALL HEIGHT MAY BE GREATER DEPENDING ON MOTOR,ADAPTER,AND/OR HINGE BASE. Performance Requested Volume(CFM) 550 0.6 0.6 _ Actual Volume(CFM) 550 1155 FRIrM — Total External SP(in.wig) 0.5 0.5 , 0.5 Fan RPM 1155 Operating Power(hp) 0.08 — — Elevation(ft) 108 W 0.4 _ 0.4 3 a Airstream Temp.(F) 70 c — Air Density(Iblft3) 0.075 m 0.3 _ • 0.3 i Tip Speed(ft/min) 3,364 rn — Il Static Eff.(%) i 53 -- — Y a- 0.2 _____.-_.-___-, 0.2 m 0 co Misc Fan Data in ,fib , Fan Elf. Index(FEI) - 0.1 _ 0.1 Outlet Velocity(ft/min) 611 5 0.0 i ii1 111 1 I 1 I III III III II 00 Motor 0 1 2 3 4 5 6 7 8 9 10 Motor Mounted Yes Volume(CFM)X 100 Size(hp) 1/4 Voltage/Cycle/Phase! 115/60/1 A Operating Bhp point Enclosure TENV 0 Operating point at Total External SP Fan curve Motor RPM 1725 -- - -System curve Efficiency Rating High Brake horsepower curve Windings! 1 FLA(Amps) 2.85 Min.Circuit Ampacity(MCA) 4 Notes: AI dimensions shown are in units of in. Max.Overcurrent Protection(MOP) 15 'NEC FLA,MCA and MOP are for reference only-based on Short Circuit Current Rtg(SCCR 5 kA tables 430.245 or 430.25 of National Electric Code 2020.Actual ) motor FLA may vary,for sizing thermal overload,consult factory. MCA end MOP values shown only account for the motor,not CIMCQ DI accessories(damper actuator,field supplied VFD,etc). COMM OITIII I.. Sound Power b Octave Band d8LwA-A weighted sound power u level,babas d 11.5d.4 RRnR6I y dBA-A weighted sound pressure level,based on 11.5 dB AMID Sound attenuation per Octave band at 5 ft-dBA levels are not licensed 62.5 125 250 500 1000 2000 4000 8000 LwA dBA Sones by AMCA International ■'R Data Sones-calculated using ANSI/AMCA 301 at 5 ft , 011011021101 Inlet 67 66 63 56 48 46 40 33 59 47 4.5 ^Ir novmrm Mn cn.rnnr FAQ, NInc,P Icr4M•nTIonOYRl.me 9\ G:\KevinHarrah\Secured 2023100-F\Dartmouth Crossing.gfcj CAPS 4.41.1100 Generated by:kharrah@johnsonair.com Page 6 of 1 1 ifiGREENHECK Printed Date: 05/26/2023 Job: Dartmouth Crossing Building Value in Air. Mark: EF-2 Model: G-100-VG Model: G-100-VG Direct Drive Centrifugal Roof Exhaust Fan Standard Construction Features: -Aluminum housing-Backward inclined composite(sizes 60-95)or aluminum (sizes 97-300)wheel-Aluminum curb cap with prepunched mounting holes- Birdscreen-Ball bearing motors(sizes 85-300 and all Vari Green),sleeve bearing motors(sizes 60-80)-Motor isolated on shock mounts-Corrosion resistant fasteners Selected Options &Accessories: Motor-Vari-Green EC motor Control-Dial for balancing Standard Curb Cap Size-19 Square UUcUL 705 Listed-"Power Ventilators" Switch,NEMA-1,Toggle,Shipped with Unit Junction Box Mounted&Wired Birdscreen:Galvanized,nom.84%Free Area Unit Warranty: 1 Yr(Standard) Selected Sub Marks See individual submittals for full details GPI-19-G12 The Varf-Green Motor included in this order has a 'Multi-Voltage'ability. The red wire on the motor is called a'Voltage Doubler,and when it is connected the motor can be powered by 115V. If the Red wire is disconnected,then the motor can be powered with 208-230/277V. The motor will leave the factory with the voltage doubler wired per the order. G:\KevinHarrah\Secured 2023\00-F1Dartmouth Crossing.gfcj CAPS 4.41.1100 Generated by:kharrah@johnsonair.com Page 7 of 11 Printed Date: /26/2023 Li GREENHECK Job: D r moutOh5Cros Crossing Building Value in Air. Mark: EF-2 Model: G-100-VG Vari-Green Motor & Control Options An EC motor that uses AC input power and internally converts it to DC power. Potentiometer (dial) mounted on the motor enclosure adjusts the speed (RPM) down 80%. Vari-Green motors feature a soft-start and inherent thermal and current protection built into each unit. Inrush current at start up is eliminated and the motor will automatically reduce speed or turn off if overloaded or it becomes too hot. Motor Configuration POWER INPUT Input Voltage: 115 BLACK 115 VAC Speed Reference: Dial on Motor WHITE NEUTRAL GREEN GROUND Permanent Dial: Yes SPEED CONTROL 11.1111.11. Control Configuration ;cry,':— Control Type: N/A Transformer: None s� VAR/�GREMOE�M VOLTAGE JUMPER CLOSED .111111111 ORLWING, 1.6.1 v4 G:1KevinHarrah\Secured 2023100-F\Dartmouth Crossing.gfcj CAPS 4.41.1100 Generated by:kharrah@johnsonair.com Page 8 of 11 LiGREEAIHECK Printed Date: 05/26/2023 Job: Dartmouth Crossing Building Value in Air. Mark: EF-2 Model: GPI-19-G12 17.50 17.50 Model: GPI Roof Curb 12.00 Standard Construction Features: -Roof Curb fits between the building roof and the fan mounted directly to the roof / \ support structure -Constructed of either 18 ga galvanized steel or 0.064 in. / \ aluminum-Straight Sided without a cant-2 in. mounting flange-3 lb density insulation-Height-Available from 12 in.to 42 in.as specified in 0.5 in. increments. Notes: -The maximum roof opening dimension should not be greater than the"Actual"top outside dimension minus 2 in.. -The minimum roof opening dimension should be at least 2.5 in.more than the damper dimension or recommended duct size.-The Roof Opening Dimension may or may not be the 21.50 21.50 same as the Structural Opening Dimension.-Damper Tray is optional and must be specified. Tray size Is same as damper size.-Security bars are optional and must be specified. Frames and gridwork are all 12 ga steel. Gridwork is welded to the frame and the frame is welded to the curb. General Sizing �Undersizing Weight Shipped Tag !Qty Model Method (In.) (lb) Assembled,Union Label 1 GPI-19 Nominal 1.5 16 Yes No Preference Dimensions Nominal Nominal Actual Actual Actual Actual Hinge Hinge Curb Outside Outside Outside Outside Inside Inside j Base Base Height Width Length Width Length Width Length Width` Length* Y12.) (In.) (in.) (in.) ' (in.) (in.) (in.) (in.) (In.) 19 19 17.5 17.5 14 14 18 18 Ma not be applicable Accessories Security Insulation Insulation Material Bars Liner (in.) R Value Galvanized No No 1 R4.3 G:\KevinHarrah\Secured 2023\00-F\Dartmouth Crossing.gfcj CAPS 4.41.1100 Generated by:kharrah@johnsonair.com Page 9 of 11 Printed Date: 05/26/2023 La"GREENHECK Job: Dartmouth Crossing Building Value in Air. Mark: EF DAMPERS Model: VCD-23 VCD-23 Low Leakage 3V Blade Volume Control Damper APPLICATION & DESIGN The VCD-23 is a ruggedly built low leakage control damper intended for applications in low to medium pressure and velocity systems.A wide range of electric actuators are available. DAMPER RATINGS Pressure: Up to 5 in.wg-pressure differential Velocity: Up to 3,000 ft/min Leakage: Class 1A @ 1 in.wg Channel Frame Class 1 @ up to 5 in.wg �, Temperature: Up to 250 F t PRODUCT DETAILS Frame Type: Channel Frame Thickness: 16 ga Material: Galvanized Blade Type: 3V 1.25 in. Blade Action: Opposed Helghl max Blade Seal Material: TPE (fYvicel) Axle/Linkage Material: Steel • Axle Bearings: Synthetic Jamb Seal Material: Stainless Steel �, Damper Temp.Rating: 180 F width Jackshafting: No Preference 5 in.f Actuator Sizing: Default SqFt . ~ Ext.Shaft Length: Standard(6 in.) Multi-Section Fastening: Standard Sizing: Nominal •This drawing shows a general damper configuration and is not intended to depict the exact configuration of all dampers in this submittal. •Width and height furnished approximately 0.250 in.undersize, ACTUATOR INFORMATION - Factory supplied actuators are sized for 1,500 !pm and a fully-closed differential pressure of 2 in.wc.Contact factory for actuator sizing on applications exceeding those Actuator Type: 120 VAC levels. Actuator Mounting: External •Installation instructions available at wwwgreenheck.com. Actuator Location: Left Side Operating Mode: TwoPosition CODES APPROVED Actuator Operation: Spring Return IECC(International Energy Conservation Code) Fail Position: Closed compliant NEMA Enclosure: Least Cost The AMCA Certified Ratings Seal applies to Air Auxiliary Switches: No Leakage and Air Performance ratings. Spring Return Time: Standard OPTIONS & ACCESSORIES Union Label: No Preference SUMMARY ID# I TAG I QTY I Width I Height I CONFIGURATION Drive Arrangement: Actuator Mfr: Actuator Model: Actuator Qty: Drive- Honeywell MS4103F1025 1 11-1 EF-1 1 10.000 in. 10.000 in. CC-11-1 FEL-0 Act.Orientation: Standoff: Perp Up 1.500 in. Drive Arrangement: Actuator Mfr: Actuator Model: Actuator Qty: Drive- Honeywell MS4103F1025 1 11-2 EF-2 1 12.000 in. 12.000 in. CC-11-1FEL-0 Act.Orientation: Standoff: Perp Up 1.500 in. G:\KevinHarrah\Secured 2023\00-F\Dartmouth Crossing.gfcj CAPS 4.41.1100 Generated by:kharrah@johnsonair.com Page 10 of 11 LGREENHECK Printed Date: 05/26/2023 Job: Dartmouth Crossing Building Value in Air. Damper Drive Arrangements Job Summary -Start- Drive Arrangement: Drive-CC-11-1 FEL-0 Damper Drive Arrangements Job Summary -End- G:\KevinHarrah\Secured 2023100-F\Dartmouth Crossing.gfcj CAPS 4.41.1100 Generated by:kharrah@johnsonair.com Page 11 of 11 Drive Arrangement Definition Actuator driven dampers are supplied with a drive arrangement code that helps describe the configuration of the damper. The following breaks down what each number and letter represents. 22-2FER- 2 so® OÔ ® ® ® ® Number of sections wide — ® Number of sections high ® Number of actuators or manual operators (such as quadrants, pull chain, etc.) Jackshaft ® Who supplies the actuators or manual operators .g) F - Factory C - Customer Supplied (field mounted) a, E ® Actuator or manual operators mounting Actuator or E External Manual Operator I - Internal B - Both internal and external Jackshaft ® Actuator or manual operators location I I L - Left hand drive R - Right hand drive — B - Both right and left �— Damper Width ® Number of jackshafts Each damper is supplied with a Drive Arrangement Prefix to help describe its construction. See the following examples: Model Drive Arrangement Prefix AMD series,AMD-TD series AMD FBH & FBV FB DFD-21 0; DFDAF-31 0, DFDAF-330; SEDFD-210 FSD, OFSD, CFSD, SMD, SEFSD, MLS SSFSD, SESMD, SSSMD series (except vertical blade models) ICD series, MBD-15 &VCD series CC (except vertical blade models) FSD-311V, SMD-301V, VCD-xxV VB Submittal Sheet Rev Date: 2021-03-01 DBF 4XLT STANDARD FEATURES •Airtight galvanized steel housing Duct Booster Fan • Permanently lubricated sealed ball bearings •Self-cleaning backward curved impeller •Automatic reset thermal overload protection • 5 1/2 foot 120Vac power cord • Five-year factory warranty 1 3 3 d 3' I. 1• - 615"a IIII 93,4 RECEIVED 1- JUN 2 0 2023 2 3',e y CITY OF TIGARD BUILDING DIVISION Model Metal Gauge Weight DBF 4XLT 22 10 Fan Specifications Motor Specifications Line Oty Model No. Tag CFM SP Fen RPM Watts Volts Phase Hertz Eric] 1 10 DBF4XLT BF-1 160 .20 65 120 1 60 ODP 2 3 4 Accessory Items 111©©11 Accessory Items p©©0 Project: Dartmouth Crossing Submitted: Customer: Hunter Davisson Approved: Location: Tigard,OR United States 1004B Industrial Blvd.•Lenexa,KS 66215•1.800.747.1762•waw.fantech-net Canada 50 Kanalflakt Way•Bouctouche,NB E4S 3M5•1.800.565.3548•www.fantech.net ••• Fantech reserves the right to make technical changes. • ••, • fantech For updated documentation please refer to www.lantech.net ••.• RECEIVED ��. VAK Construction Engineering Services, LLC JUN 2 0 2023 VA 8285 SW Nimbus Avenue,Suite 104 Beaverton,Oregon 97008 CITY OF TIGARD 503.718.5999 tel 503.718.5980 fax BUILDING DIVISION soardner(o7vakenai neering.com M E M O TO: Steve Pickar, CDI Curbs Job # 20-001 DA FROM: Sam Gardner P.E., VAK Engineering PROJECT: 7XXX Stock Update DATE: 4/19/2021 RE: C7-00XX-7723 Iso Curb and Fastening Design As requested we have reviewed the isolation curb and attachments at stock locations to support seismic and wind design loads for the Daikin units. Operating weight of the unit was between 1,6001b and 2,8321b received specifications. The roof itself and weight of ductwork were not included in this analysis. Ap=2.5 Building Height: 60'0" Building Category: IV Rp=2.0 Site Soil Class: D Exposure: C Ie= 1.5 SOS: 1.330g Basic Wind Speed: 185mph Based on the wind and seismic analyses we determined the governing load conditions for vertical loading and shear. Here are our findings from the analysis of the curb supporting the rooftop unit. Reactions Summary Long Side(x) Short Side (y) Per Side of Curb (lb) (lb) Unit to Curb Connection Maximum Tension 5796 3692 Maximum Compression 8041 5619 Maximum Shear 5299 6856 Curb to Surface Connection Maximum Tension 12518 5935 Maximum Compression 15420 9353 Maximum Shear 5673 7674 Therefore, based on the design criteria provided, we have applied both wind and seismic reactions to the unit and curb to determine the fastening requirements. During our analysis,we determined that • (14) #14 TEK screws will be required per each long side of the curb through the unit boxed rail into both unit and curb with(8) per short side for a total of(44). We checked the adequacy of the connection of the curbs to the structure, and the curb itself. The top of the curb was also checked in flexure and shear and was found to be adequate. Isolators were assumed to be the JQA models, requiring a minimum of: • (6)per curb long side and(3)per curb short side for a total of(18) springs. The spring supports were also checked in compression and found to be adequate. The bottom flange was checked in flexure and was found to be adequate if hemmed. Filename:21 001DA 7723 LTR01 04 21 2021 Page 1 of I VAK MEMO 4/19/2021 ' Connection of the curb to the roof requires fasteners on both sides of the curb. Without knowing which fasteners to be used, 0.5" 0 A307 Bolts into steel, '/a" SDS Wood Screws into wood, and 3/8" Simpson Strong Bolts with 1.875" effective embedment into concrete were checked. From our analysis, we recommend one of the following: • (10) 0.5" 0 A307 Bolts per long side with (6)per short side for a total of(32). • (16) 1/4" SDS Wood Screws with a 3.5" embedment per long side with (12)per short side for a total of(56). • (24) 3/8" Simpson Strong Bolts with 2.5" of effective embedment per long side of curb with (15) per short side for a total of(78). If concrete is used, at least 18" of edge distance and 6" of depth is necessary. Anchors shall be placed such that there is a fastener on the long edge at least 6" from the short end of the curb. For each fastener, install per manufacturer specifications and located 5/8" away from the curb wall. Please feel free to contact us should anything further be required or if questions arise. Best Regards, Sam Gardner, P.E. 04/20/2021 04/20/2021 04/20/2021 �I11111//� `S���Ep Pfl k % •�~.aA\NJ/fa tc4s' \• * �,,ENSyF�,iA / et —w• / i � . 845 Ail- .t.: - , 4;EGON , . M ZO r � ��< O3, 0 Q _ • Q` •• '/ �5�� LE.X111RES: lv3 U flifillIP Zza 24"1-3 04/20/2021 / Q`y0ESS/ONmEs v iti - o Z c9 m 313 X a- w Filename: 21 001DA 7723 LTR01 04 21 2021 Page 2 of T ..I._:l.l.(.Pbila DININI)14I4G114. REVISIONS DUCT FLEX CONNECTIONS PROVIDED BY OTHERS REP ECG. DESCRIPTION DATE APPROVED 1 X 4 WOOD NAILER I INRLALDRAWIN° II/I/18 SRP SPRING ACCESS DOORS ARE GASKETED AND SCREWED ON 2 UPDATED IBC,CRC a rx 4/15/2I SRP _ FROM DRAWING GASKET MATERIAL PROVIDED FOR THE TOP OVERALL 231M 281M 301M 381I4 140A BOXED TOP FRAME PERIMETER(INCLUDING BRACES) HEIGHT SPRING PACKS MAY REQUIRE FIELD ADJUSTMENT BASE CURB HEIGHT 11 14 18 24 RETURN (BY OTHERS) EASE MATERIAL GA 14 14 14 14 \, FULLY WELDED GALVANIZED(DSO)CONSTRUCTION CURB WEIGHT 454 478 510 558 N WEATHER SEAL BETWEEN UPPER S LOWER S \ 18GA DUCT BRACES SECTIONS PROVIDED(BULB SEAL) 4 1 I ANCHORING CURB TO ROOF FOR STEEL,CONCRETE OR WOOD,SEESNO.SEISMICAIL C--ATTTG ACHMENTS ANCHOR" 1 .....� '\-.!r\ SUPPLY 1144 AL4 IIIIIIII r CURB EASE IC 1 38 7/8" `�I ` /` 14GA SPRING CO SUPPORTSRINEA(INSULAT ) \ / PRR UNDER 11, Ce 5"REF HEM BASE FLANGE 22"—wl 23/4" r , �3512" UNIT BASE RAIL I A 59 3/4" 4. 901/4" 1/6"TEK SCREW THRU •_ UN IT BASE RAIL AND CURB PER STAMPED REPORT ■ 581/4" � 10S 1/2" S23/8" 2" .I F� 102.I.D. 11 I I 4E T/E"BASE CURB I D. i U L_ . 1" CURB -.111111111111111 ` '�— BASE t12 rrr }f} T -- (36'MAX WITH PITCH) J I I — -I BASEHEIGHT CVRB I_._I 11II I SCALE 1L: G 1 4 1— MIS CURB DESIGNED TO MEET SEISMIC A WIND LOAD REQUIREMENTS FOR _ mil mow' °1Ri m` pl..1. Of CRYSTAL INSMBUTIC.NC 2518 IBC/ASCE TIC AND 2020 FRC FLORIDA BUILDING CODE,2019 CRC 4]8.16 .Pd> C7-OOXX-7723 69 WINO DESIGN:MAX BUILDING HEIGHT FT,KD FACTOR 1.00 MAX SEISMIC ISOLATION CURB :i° `""'"`°e"°°'"'°" --m— �• - 3D ASSEMBLYC..i141/1.11-10X COI RESERVES THE FIRfr IV TRsdw ADA20 2021 T1220 NI 201E IBC/ASCE]18:MAX 185 MPH ULTIMATE DESIGN WIND SPEED.RISK , !„y! 1]lBO TYLBB STXW 'UMW. =••" CATEGORY II,III,OR IV BUILDING,EXPOSURE C _ _ CDI LGK RIVEN.W sIw Ci-pOxr-nf3 'j SEISMIC:Es-2.00 MAX,IMPORTANCE FACTOR Ip-15 1,1,1,.......COKIEURKTION MIIALITHE Renrm next rr QQ �M TTM 2 �•! I4►43 DMPR1-]4R1 ®" .u. 192 I AA 1 a 9 S:ICURBS CURB ADAPTERSICX-XXXX-XXXX CONFORMINGIC7-)O0O(2004 ISO CURBS RAILSIGT XXXX-7)00007-09XX-]7231 \ T- 14GA TOP BOXED FRAME I/i >. 2 I\ tg LL 7 7 W en ' II - ce I \ JOA SPRING PACK lii FE 1 3/4' I!L MIN 14GA SPRING SUPPORT I 12GA BASE CURB 3 ---..-1SECTION L-L SCALE 1 : 4 M1., _ "▪ _°am + X, 478.16 w. C7-OOXX-7723 SEISMIC ISOLATION CURB " "a""w°-aaa.G+ - riMM AMm 29217:6119 N.1 3D ASSEMBLY !ea nmmaar xw c7nov-m1 2 cu▪m.tArdn win on NOTIFICATION r _ CDI EOM:" :"5S110 Nx FORAGING NNm0E" Nmururww Y^~I.a D�»+-T151 �• +wc 1:22 I er:1 a 9 SACURBS_CURB_ADAPTERS\CX-X[XXXbIX_CONFORMING\C7-XICOOO OCISO CURBS_RAILGC74COIX-MGICr-0OX%-7723\ �9 O..O.eYIO TO,!Wv6.EYWIT14 .1 SPRING LAYOUT LOCATIONS RETURN MIN SPRING LOACATIONS . A, AB1 B, BC1 C, CD1 D, DA1 , , i�, SUPPLY A61 A62 B BC2 BC1 ' J Z D_ cca A /- y C w / \ DA1 DA2 D CD2 CD1 CURB SHOWN IS COI STANDARD CONFIGURATION MAMMaNNu d,< M. CBI RESERVES THE RIGHT TO CHANGE LAYOUT V.I.' C7-OOXX-7723 WITHOUT NOTIFICATION.IF CURB IS NEEDED IN A DIFFERENT CONFIGURATION COI MUST BE NOTIFIED TMNIaw...OM 2921 7:4219 AN PRIOR TO PLACING AN ORDER. •w TEMlINu UM Ou .,,,� v9M rr�a"sr NW hawse �^ 'VERIFY SUPPLY MD NNiuNN YPEIIIXW _ /y CT-004C-77237. 'NOTE ANY CHANGES ® I w / DI ELK aIYER MN ES]]9 ed. �6 CNIL Yall1UV ouEsnoon ��^^ v 1 (1TM]H1.n90 4C BACK N ORAN.*b ON M p wti -V (i 1-1151 1:19 I sae 9 r 9 STEEL ATTACHMENT CONCRETE ATTACHMENT 1 CURB ASSEMBLY CURB ASSEMBLY 112'IO A307 BOLTS OR EQUIVALENT EQUALLY SPACED ON CURB BASE FLANGE 3I8'0 SIMPSON STRONG BOLT 2 EQUALLY ATTACHED TO LSXS%SNB'BELOW DECK AT SPACED ON CURB BASE FLANGE.I SIT EFFECTIVE SHEATHING EACH CONNECTION POINT EMBEDMENT OR PER STAMPED CALCULATION WHERE SPECIAL INSPECTION REQUIRED OCCURS (ESR REPORT 3037) METAL DECK , 'CONCRETE SLAB: I'c=IOWpx MINIMUM NORMAL WEIONT CONCRETE a' Fro". MININIUM THL E OVERSS IAL DECKUM EDGE DISTANCE EMBED PER STAMPED 'CONCRFrE OVER METAL DECK' STRUCTURAL STEEL SUPPORT "ILOOF CACULATION UUSSEEMING BELOW DECK TCOMRECTION TO STEEL BY OTHERS CONCRETE /Z. WOOD ATTACHMENT 1 CURB ASSEMBLY I 1M•SDS WOOD SCREWS OR EQUIVALENT EQUALLY SPACED ON CURB BASE FLANGE 312E �rs.veux u1E xa EMBED x.wwrsRgmm CIS uruiaa... mu... .w auxin•L.xsmumi cwmwrex ..wx....,°"a,"a,":,� • .a..•P�a. =an118 CUR&ATTACHMENTS w 0.` Caxla ma 4I8 •1.-," ......:: IJYd]HMI 115 I s 1 s 1 CO COI Curbs z1-0OIGA 7XXX Stock Update Curb Analysis and Design S.Gardner Construction Engineering Services Seismic and Wind Loads Seismic&Wind Loads alue Units Reference/Notes Inputs Unit Information Long Side(x) I,,,,, 111.000 in Additional Wind Length I„a, 21.700 in Short Side(y) w,„s 57.900 in Additional Wind Width won,, 38.600 in Height(z) h,„, 55.800 in Additional Wind Height h,,,, in Weight W,„, 1600.00 lb Center of Gravity(x) CG, 21.20 in Center of Gravity(y) CO, 21.70 in Height above Exposure Bomb level,e Center of Gravity(z) Co, 35.60 in e c II A (MI Curb Information 0-15 (0a 61 157 085 I03 as (6.1) 0.63 090 108 Long Side(o) loon 102.000 in 25 (7.6) 0.66 0.94 1.12 311 (9.1) 0.70 a.04 1.is Short Side(y) woos, 48.875 in 40 (122, 016 iW 122 Height(z) ho,„ 23.250 inso U6.A u.n1 .3 127 Weight Woo,, 500.00 lb (la) 089 1.17 Lsl ]0 (21.31 089 I.21 I.38 Xo (2,d) a.96 I21 14a Center of Gravity(x) CO, 51.00 in _ 90 Ina) 099 24 I43 Center of Gravity120 13661 n04 I.31 IA3 (V) CGY 24.441n 1,-o (42.7) 1.09 1.31 I.52 16O....' 148.81 109 139 1 32 180 154.81 1.17 1 43 I SS Seismic Design Criteria - I80 (34.0 1.11 1 443 6 1 sa Project Location STOCK 250 (702) 1.2n 146 168 250. _.,_ (9141 12a 1.S1 1.6a Risk Category IV 3ro t910) _.._1.3s 1.59 1.73 151) (Ie6.1) l- IA1 1.69 1.78 Site Soil Class 0 400 (121.91 _ 1.47 1.69 1.82 450 (111.21 152 1.73 1M Mean Roof Height H 60.00 ft SW I152.4, 15,, 177 1.89 Height at Attachment Z 60.00 ft Importance Factor I, 1.50 Table 1.5-2 Risk Category I4 Component Amplification Factor a, 2.5 Table 13.6-1(Default 2.5) I 1.00 Component Response Modification Factor R, 2.0 Table 13.6-1(Default 6 far non-isof II 1.00 Spectral Acceleration Sp, 1.330 Section 11.4.5 ar USGS Mops III 1.25 Overstrength Factor D 1.0 Table 15,4-1(Concrete/Masonry Only) IV 1.50 Wind Design Criteria Building Category(1I,II1,or IV) IV Exposure Category C Section 26.7.3 Wind speed V 185 mph Fig.26.5-1 Exposure coefficient K. 1.13 Table 26.10-1 Topographic factor Ka 1 Section 26.8.2(Default l( Wind directionality K1 0.85 Table 26.6-1(Default0.851 Gust effect factor(lateral) GC, 1.9 Section 29.4.1[Default 1.9] Gust effect factor(uplift) GC, 1.5 Section 29.4.1(Default 1.4 Minimum Design Pressure(Lateral) qn psf Project Specifications Minimum Design Pressure(Uplift) On psf Project Specifications Snow Load Roof Snow Load S 0 psf Resultant Weight S 0 lb 4/20/2021 • CDI curbs 31-0atDA 7XXX study Update • 1 Curb Analysis and Design 5.Gardner Seismic and Wind Loads Construction Engineering Services Geometry alue Units Reference/Notes Intermediate Calculations Weights W,,,,, 1600 lb W5„q 500 lb Wrab; 2100 lb Horizontal Centers of Gravity(x) [Gura 21.2 in CGC„,, 51.0 in CGrm,i=(Wan x CG.oac+W„ax CGo„a)/(Wes •W„,) CG.m,i 28.3 in Horizontal Centers of Gravity(y) CO,,, 21.7 in CGr„n 24.4 in CG,a,i-IWwn x CG..„n+W,,N CG„,„J/IWan+Wuna) CGrool 22.4 in Vertical Centers of Gravity(z) CGu„n=h..,e+CG,,,a CG,,,,;, 58.9 in h,„,/2 CGan 11 6 in Assume curb CG is 1/2 Height CGrml=(W,s0 CG.an+W.,mx CG,,,a,)/(Waro+W.w) CG,a, 47.6 in Vertical Center of Volume(z) CV., 27.90 in NC„s 11.63 in N,a,l 39.53 in Areas h,.,n+4.n hw„ 79.1 in A.(Unit).(I+l,aa)a)h,h,,,) 51.4 ft' A,Iling)_(w+we,)x(h+hca) 37.4 ft' A,(Unit+Curb)=(A„a)a-(I x h)an 67.9 ft' Av IUnit+Curb)=(Nam)+Iw xhlon 45.3 ft' A,(Unit)=(I+1,,,)x(vow,,,) 88.9 ft' Horizontal projected area of unit 4/20/2021 C01 Curbs 274/O10A • 7XXX Stock Update Curb Analysis and Design 8.Gardner Construction Engineering Services Seismic and Wind Loads Wind Loads Value Units Reference/Notes Design Wind Loads-Other Structures Horizontal Force(Unit Only) K, 1.13 K,, 1 K 0.85 K, 1.00 Table 26.10.1(Conservative approx.1.00) ✓ 185 mph qn=0.00256K,KaK,K,V qn 84.16 psf EQ 26.10-1 qn 84.16 psf Greater of project spec minim/fa and colt GC, 1.9 M. 51.4 f A„ 37.4 f F=gn(GC,)A F, 8222 lb EQ.29.4-2 F, 5979 lb Horizontal Force(Unit+Curb) F. "., ,, al.',,�a., K, 1.13 Ka 1 Ke 0.85 K, 1.00 Table 26.10.1(Conservative approx.1.00) ✓ 185 mph qn=0.00256K,K0K,K,V' qn 84.16 psf EQ 26.10-1 tin 84.16 psf Greater of project spec marimba and colt GC, 1.9 Ai, 67.9 ft' 45.3 re F=gn(GC,)A, F, 10855 lb EQ.29.4-2 7241 lb Design Forces Unit Only F, 8222 lb ASCE 29.8 Minimum Design Wind Loading=16'(Ar) F, 5979 lb Unit+Curb F, 10855 lb - F, 7241 lb Shear Unit to Curb V. F./2 V, 4111 lb V,=F,12 V, 2990 lb Curb to Roof V,=F,/2 V. 5428 lb V,=F,12 V, 3620 lb Vertical Uplift Force K 1.13 Ka 1 K 0.85 ✓ 185 mph gn=0.00256K,Kalc,V' qn 84.16 psf 9n 84.16 par Greater of project spec minimim and oak GC, 1.5 A, 88.9 ft' F,=%MC,)A, F, 11226 lb EQ 29.4-3 4/20/2021 £ ) CDI camp zt-ow 0a ]%]O( Update Curb Analysislysis and Design S.Gardner Seismic and Wind Loads Centro tion Engineering Services Seismic Loads alue Units Reference/Notes Seismic Demand on Nonstructural Components Horizontal Force(Unit Only) Fe=[0.4a,5n,W✓IR,/I,)]I1+21z/h)) F, 4788 lb ASCE 7-16 EQ.13.3-1 2.5 S0s 1.330 W. 1600 lb B, 2.0 1.5 60 h 60 Upper Bound=1.650si,W, F,,M 5107 lb EQ 13.3-2 Lower Bound=0.3S,yi,W, F,,M, 958 lb EQ I3.3-3 4788 lb Horizontal Force(Unit+Curb) F,=(0.4a,S0.W✓(R✓ia Mlle/h)) F. 6284 lb as 2.5 Sas 1.330 W, 2100 lb R, 2.0 I, 1.5 60 h 60 Upper Bound=1.65001,W, F,e,,, 6703 lb Lower Bound=0.3Sn51,W, F3.00 1257 lb Foo,„,, 6284 lb Basic Combination for Strength Design[Unit Only) Lower Bound=(0.6-0.1450.)0+0.7p00+H LB, 662 lb 12.4.2.3-8 Upper Bound=(1.0+0.1450a0+H+F+0.7p0c UB, 1898 lb 12.4.2.3-5 _(1.0+0.1Sns)D+H+F+0.525pQz+0.75L+0.75(L,or 5 or R) UB0 1813 lb Spectral Acceleration SOS 1.330 Weight of Component 0 1600 lb Redundancy Factor p 0 Effects of Horizontal Sesmic Forces C4 0 Earth Pressure H 0 lb Fluid Load F 0 lb Snow Load 5 0 lb Basic Combination for Strength Design(Unit+Curb) Lower Bound (0.6-0.145,J0-0.7p0.0.H LB, 869 lb Upper Bound (1.0+0.145017+H+FW.7pQc UB, 2491 lb =(1.0+0.1S00D+H+F+0.525p0E+0.75L+0.75(L,or 5 or R) UB0 2379 lb Spectral Acceleration Sos 1.330 Weight of Component D 2100 lb Redundancy Factor p 0 Effects of Horizontal Sesmic Forces Cic 0 Earth Pressure H 0 lb Fluid Load F 0 lb Snow Load S 0 lb Design Forces Unit Only F,o„1,,, 4788 lb • LBo 662 lb UBn 1898 lb Unit+Curb F,,,d,,, 6284 lb LB0 869 lb UB, 2491 lb Shear Unit V,=F,(dGJL) F=max(V„V0) V, 3874 V,=Fo 11-ICG,/L)) V, 2994 Unit+Curb V, 4541 V, 3410 4/20/2021 C C0 Curbs 2t-0m OA 7XXX Stuck Update Curb Analysis and Design S.Gardner Seismic and Wind Loads Construction Engineering Services Statics Moments(Overturning,Riding) Combinations(20) Scenario Force Weight CD/V,' CD., OTM Rid.M Res.M. D24 R1 R2 Ps) Pis) (in) (In) (Ib-ft) (lb-ft) (lb-ft) (in) (lb) (lb) Unit,Fe,Seismic,LBd 4788 662 35.6 21.7 -14204 1197 -13007 48.88 -3194 3856 Unit,Fe,Seismic,UBd 4788 1898 35.6 21.7 -14204 3432 -10772 48.88 -2645 4543 Unit,Fe,Wind,O+0.6W-0.6Fv 4933 -5135 27.9 21.7 -11470 -9286 -20756 48.88 -5096 -39 Unit,Fe,Wind,Ot0.75(O.6W)-O.75(0.6Fv) 3700 -3451 27.9 21.7 -8602 -6241 -14844 48.88 -3644 193 Unit,Fe,Wind,0.6D+O.6W-0.6Fv 4933 -5775 27.9 21.7 -11470 -10444 -21913 48.88 -5380 -395 Unit,Fy,Seismic,LBd 4788 662 35.6 21.2 -14204 1170 -13035 102.00 -1533 2196 Unit,Fy,Seismic,UBd 4788 1898 35.6 21.2 -14204 3353 -10851 102.00 -1277 3175 Unit,Fy,Wind,D+0.6W-0.6Fv 3587 -5135 27.9 21.2 -8341 -9072 -17413 102.00 -2049 -3087 Unit,Fy,Wind,D+O.75(0.6W)-0.75(D.6Fv) 2691 -3451 27.9 21.2 -6256 -6098 -12353 102.00 -1453 -1998 Unit,Fy,Wind,0.6D+O.6W-0.6Fv 3587 -5775 27.9 21.2 -8341 -10203 -18544 102.00 -2182 -3594 Unit+Curb,Fe,Seismic,LBd 6284 869 47.6 22.4 -24931 1619 -23312 48.88 -5724 6593 Unit+Curb,Fe,Seismic,UBd 6284 2491 47.6 22.4 -24931 4640 -20291 48.88 -4982 7473 Unit+Curb,Fe,Wind,D+O.6W-O.6Fv 6513 -4635 39.5 22.4 -21453 -8634 -30087 48.88 -7387 2752 Unit+Curb,Fe,Wind,D+O.75(O.6W)-0.75(O.6Fv) 4885 -2951 39.5 22.4 .16090 -5498 -21587 48.88 -5300 2349 Unit+Curb,Fx,Wind,0.6O+O.6W-0.6Fv 6513 -5475 39.5 22.4 -21453 -10199 -31651 48.88 -7771 2296 Unit+Curb,Fy,Seismic,LBd 6284 869 47.6 28.3 -24931 2049 -22882 102.00 -2692 3561 Unit+Curb,Fy,Seismic,UBd 6284 2491 47.6 28.3 -24931 5874 -19057 102.00 -2242 4733 Unit+Curb,Fy,Wind,D+O.6W-O.6Fv 4345 -4635 39.5 28.3 -14310 -10930 -25240 102.00 -2969 -1666 Unit+Curb,Fy,Wind,D+O.75(O.6W)-O.75(0.6Fv) 3258 -2951 39.5 28.3 -10732 -6959 -17692 102.00 -2081 -870 Unit+Curb,Fy,Wind,0.6O+O.6W-0.6Fv 4345 -5475 39.5 28.3 .14310 -12910 -27220 102.00 -3202 -2273 1. CG of Unit is relative to curb top 2, Overturning moment multiplied by 0 3. Overturning considered negative 4. Conservatively assume the smaller distance of the unit or curb Reactions Summary Long Side(X) Short Side(y) Per Side of Curb (lb) (lb) Unit to Curb Connection Maximum Tension 5380 3594 Maximum Compression 4543 3175 Maximum Shear 2994 4111 Curb.to Surface Connection Maximum Tension 7771 3202 Maximum Compression 7473 4733 Maximum Shear 3620 5428 4/20/2021 ��\ CDI Curbs /) lxxx Stock Update 21-001DA \N 4 / Curb Analysis and Design S.Gardner Seismic and Wind Loads construction Engineering Unloose Seismic&Wind Loads aloe Units Reference/Notes In. Unit Information Long Side(x) I,,,n 111.000 in Additional Wind Length I,ae. 38.700 in Short Side(y) w„„n 57.900 in Additional Wind Width w,4a, 38.600 in Height(z) h„„r 55.800 in Additional Wind Height h,aa 0.000 in Weight W„,a 2832.00 lb Center of Gravity(x( CG, 21.20 in Center of Gravity(y) CG, 21.70 in Height.°'^„ Escm5re ground leech 6 Center of Gravity(z) CO, 35.60 in n C D n m1 IFIS 0-16) JS7 11.65 1.031'111Curb Information 20 In.11 one 090 1.08 . ., Long Side(x) I,„n 102.000 in zs _ i716066 0.94 I,I) w one u.9X 116 No Short Side(Y) wan 48.875 in 40 076 1.04 1.22 50 11573 0.111 109 127 Height(z) h„n 36.250 in 60 (I81 0..85 1.13 1.31 Weight wan 642.00 lb 70 21.3) 0.e9 1.171.34 Xn 24 a) 1).93 1.4 1.38 ( Center of Gravity(x) CG, 51.00 In 90 224) 096 12 140 100 (3133) 0.99 1.26 1.43 Center of Gravity(y) CGy 24A4 in 120 (36.6 09 i 31 146 140 42J) 1 1.36 1.52 I046.X) 113 139 L55 _.ea Seismic Design Criteria ISO (549) 1.17 143 I.SX STOCK 2W (610) 1.20 146 Project Location 230 (76.2) 1.28 1 53 1.68 Risk Category IV Ap (YLa) IJS 1.59 I1.733 g 350 fltifi.71 Lal 1.64 178 Site Soil Class D Jr(1 (1219) 147 1.69 1.82 450 _ 1137.2) 152 1.73 Mean Roof Height H 60.00 ft 500 I15241 156 1.77 1.89 Height at Attachment Z 60.00 ft Importance Factor 1, 1.50 Table 1.5-2 Risk Category I, Component Amplification Factor a, 2.5 Table13.6-1[Default 2.51 I 1.00 Component Response Modification Factor R, 2.0 Table 13.6-1[Default 6 for non-iso) II 1.00 Spectral Acceleration S. 1.33 Section 11.4.5 or USGS Mops III 1.25 Overstrength Factor O 1.0 Table 15.4-1(Concrete/Masonry Only) IV 1.50 Wind Design Criteria Building Category(11,111,or IV) IV Exposure Category C Section 26.7.3 Wind speed V 185 mph Fig.26.5-1 Exposure coefficient Kr 1.13 Table 26.10-1 Topographic factor ICJ 1 Section 26.8.2)Default l) Wind directionality K4 0.85 Table 26.6-1[Default 0.85) Giant effect factor(lateral) GC, 1.9 Section 29.4.1)Default 1.9) Gust effect factor(uplift) GC, 1.5 Section 29.4.1[Default 1.51 Minimum Design Pressure(Lateral) q1, 0.00 psf Project Specifications Minimum Design Pressure(Uplift) qh 0.00 psf Project Specifications Snow Load Roof Snow Load 5 0 psf Resultant Weight S 0 lb • 4/20/2021 CD!Curbs 21-001DA 7XXXUpdate Curb Analysislysis Stockand Design 9.Gardner Construction Engineering Services Seismic and Wind Loads Geometry aloe Units Reference/Notes Intermediate Calculations Weights 'Alma 2832 lb Wr„a, 642 lb Wrwi 3474 lb Horizontal Centers of Gravity(a) CGw;, 21.2 in CGr„, 51.0 in CGrw=lW,,nx CG„„,,+Wm,x CG.„„;J/lWb+W„,n) CG,,,; 26.7 in Horizontal Centers of Gravity(y) CG„„, 21.7 in CG5„,b 24.4 in CGrw;=IW„,mx CGn„,b+W„„nx CG,,J/IW„n+W,a,) CG,„,,; 22.2 in Vertical Centers of Gravity(z) CGa,„,=ha,b+CG,,,,a CGwu 71.9 in CGr„,s=h,„,b/2 CGr„,b 18.1 in Assume curb CG is 1/2 Height CGreui=(W,„puCG„„„+Wm,x CG,„„,)/(W,„n+W,.,m) CGr„b, 61.9 in Vertical Center of Volume(z) 27.90 in CV,„ 18.13 in CV.,,,; 46.03 in Areas h,„,b h,„,,; 92.1 in A,(Unit)=(I+1,J x(h+h,w7 58.0 ft' A,(Unit).(w+w,aal x(h+h,w) 37.4 ft' A.(Unit+Curb)=(Awe/a(I a h(se 83.7 ft' A,(Unit+Curb(=(A,„,e)+I W x h),„,b 49.7 ft' A(Unit)=(DLO a(w+wa) 100.3 ft' Horizontal projected area of unit • 4/20/2021 �� CDI Curbs 21-001 DA ! 7XX5 Stock Update Curb Analysis and Design S.Gardner Seismic and Wind Loads Construction Engineering Sender Wind Loads Value Units Reference/Notes Design Wind Loads-Other Structures Horizontal Force(Unit Only) K, 1.13 Kn 1 Ka 0.85 K, 1.00 Table 26.10.1(Conservative approx.1.00) V 185 mph qs=0.00256K,K„K,K,V' qh 84.16 psf EQ 26.10-1 qh 84.16 psf Greater of project spec minimim and colt GC, 1.9 Ar. 58.0 ft Ae, 37.4 ft' Fe gh(GCj4, F, 9275 lb EQ.29.4-2 F, 5979 lb Horizontal Force(Unit+Curb) K, 1.13 Ka 1 Ka 0.85 K, 1.00 Table 26.10.1(Conservative approx.1.00) Y 185 mph qh=0.00256K,K,,K,K,V' chi 84.16 psf EQ 26.10-1 qs 84.16 psf Greater of project spec minimim and cafe GC, 1.9 p 83.7 ft' Arr 49.7 Ft' F=g5IGCLA, F, 13381 lb EQ.29.4-2 F, 7946 lb Design Forces Unit Only F, 9275 lb ASCE 19.8 Minimum Design WindLoading=l6'(Arl F, 5979 lb Unit+Curb F, 13381 lb F, 7946 lb Shear Unit to Curb V,=F,j2 V, 4638 lb V,=F,/2 V, 2990 lb Curb to Roof V,=F,/2 V, 6690 lb V,.F,/2 V, 3973 lb Vertical Uplift Force K, 1.13 K,, 1 K 0.85 V 185 mph qh=0.002561(,K„K,V qn 84.16 psf q, 84.16 psf Greater of project spec minimim and colt GC, 1.5 A, 100.3 ft' =gsIGC,7A, F, 12664 lb EQ 29.4-3 4/20/2021 C CD!Curbs 21-0a10A 71 Stock Update Curb Analysis and Design S.Gardner Seismic and WInd Loads Construction Engineering Services Seismic Loads Value Units Reference/Notes Seismic Demand on Nonstructural Components Horizontal Force(Unit Only) Fp=l0.4a0Sc5Wo/(Ro/1,)111+21z/hl) F, 8475 lb ASCE 7-16 EQ.13.3-1 2.5 Sin 1.330 W, 2832 lb R, 2.0 1.5 60 h 60 Upper Bound=1.65,4w, Fwuu 9040 lb EQ13.3-2 Lower Bound 0.3SmInW, F0_u„ 1695 lb EQ 13.3-3 Fp,,R„p 8475 lb Horizontal Force(Unit+Curb) Fp=[0.4apSpsWp/ltc/ip)111+2(z/h)) Fp 10396 lb a, 2.5 S,s 1.330 W, 3474 lb R 2.0 1.5 z 60 h 60 Upper Bound=1.654,W, Farnm 11089 lb Lower Bound=0.35,sliWp F,,u,x 2079 lb Fo0c,i 10396 lb Basic Combination For Strength Design(Unit Only) Lower Bound=(0.6-0.14S,jD 0.7pQ,+H LB, 1172 lb 12.4.2.3-8 Upper Bound=(1.0t0.1450w)D+H+F+0.7p0, UB, 3359 lb 12.4.2.3-5 =(1.0+0.15,5)D+H+F+0.525p0+0.75L 0.75(L,or 5 or R) UB, 3209 lb Spectral Acceleration S,p 1.330 Weight of Component D 2832 lb Redundancy Factor p 0 Effects of Horizontal Sesmic Forces CIF 0 Earth Pressure H 0 lb Fluid Load F 0 lb Snow Load 5 0 lb Basic Combination for Strength Design(Unit+Curb) Lower Bound=(0.6-0.145,p)D40.7pQ+H LB0 1438 lb Upper Bound=(1.0+0.145,+)D+H+F+O.7paa UB, 4121 lb (1.0+0.1S,5)D+H+F+0.525pQ++0.75L+0.75(L.or S or R) UB, 3936 lb Spectral Acceleration Sg 1.330 Weight of Component 0 3474 lb Redundancy Factor p 0 Effects of Horizontal Sesmic Forces C}, 0 Earth Pressure H 0 lb Fluid Load F 0 lb Snow Load S 0 lb Design Forces Unit Only F 8475 lb La, 1172 lb UB, 3359 lb Unit+Curb F 10396 lb LB, 1438 lb Ue, 4121 lb Shear Unit V,=Fp(CG,/L) F mas(V„Vp) V 6856 V,=Fp)1-lCG,/LI) V, 5299 Unit+Curb V, 7674 V, 5673 4/20/2021 (O�� CDI Curbs Stock Update 21-01110A • Curb Analysis and Design 5.Gardner Seismic and Wind Loads Construction Enginearieg Services Statics Moments(Overturning,Riding) Combinations(20) Scenario Force Weight CON,' CG,-, OTM 4° Rid.M Res.M. 02° Rl R2 (Ins) (Ibs) (in) (in) (lb-ft) (lb-ft) (Ib-ft) (In) (Ib) (Ib) Unit,Fe,Seismic,LBd 8475 1172 35.6 21.7 -25142 2119 -23023 48.88 -5653 6824 Unit,Fe,Seismic,UM 8475 3359 35.6 21.7 -25142 6075 -19067 48.88 -4681 8041 Unit,Fe,Wind,0+0.6W-0.6Fv 5565 -4766 27.9 21.7 -12939 -8619 -21558 48.88 -5293 527 Unit,Fx,Wind,D+0.75(0.6W)-0.75(0.6Fv) 4174 -2867 27.9 21.7 -9704 -5184 -14888 48.88 -3655 789 Unit,Fe,Wind,0.6Or0.6W-0.6Fv 5565 -5899 27.9 21.7 -12939 -10667 -23606 48.88 -5796 -103 Unit,Fy,Seismic,LBd 8475 1172 35.6 21.2 -25142 2070 -23071 102.00 -2714 3886 Unit,Fy,Seismic,UBd 8475 3359 35.6 21.2 -25142 5935 -19207 102.00 -2260 5619 Unit,Fy,Wind,D+0.6W-0.6Fv 3587 -4766 27.9 21.2 -8341 -8420 -16761 102.00 -1972 -2794 Unit,Fy,Wind,D+0.75(0.6W)-0.75(0.6Fv) 2691 -2867 27.9 21.2 -6256 -5064 -11320 102.00 -1332 -1535 Unit,Fy,Wind,0.60+0.6W-0.6Fv 3587 -5899 27.9 21.2 -8341 -10422 -18762 102.00 -2207 -3692 Unit+Curb,Fe,Seismic,LBd 10396 1438 61.9 22.2 -53644 2660 -50984 48.88 -12518 13955 Unit+Curb,Fe,Seismic,UBd 10396 4121 61.9 22.2 -53644 7626 -46019 48.88 -11299 15420 Unit+Curb,Fe,Wind,0+0.5W-0.6Fv 8029 -4124 46.0 22.2 -30793 -7632 -38425 48.88 -9434 5310 Unit+Curb,Fx,Wind,D+0.75(0.6W)-0.75(0.6Fv) 6021 -2225 46.0 22.2 -23095 -4117 -27211 48.88 -6681 4456 Unit+Curb,Fe,Wind,0.60+0.6W-0.6Fv 8029 -5514 46.0 22.2 -30793 -10203 -40996 48.88 -10066 4552 Unit+Curb,Fy,Seismic,LBd 10396 1438 61.9 26.7 -53644 3199 -50445 102.00 -5935 7372 Unita-Curb,Fy,Seismic,UBd 10396 4121 61.9 26.7 -53644 9171 -44473 102.00 -5232 9353 Unit+Curb,Fy,Wind,D+0.6W-0.6Fv 4768 -4124 46.0 26.7 -18287 -9179 -27465 102.00 -3231 -893 Unit+Curb,Fy,Wind,0+0.75(0.6W)-0.75(0.6Fv) 3576 -2225 46.0 26.7 -13715 -4951 -18666 102.00 -2196 -29 Unit+Curb,Fy,Wind,0.60.10.6W-0.6W 4768 -5514 45.0 26.7 -18287 -12271 -30558 102.00 -3595 -1919 1. CG of Unit is relative to curb top 2. Overturning moment multiplied by D 3. Overturning considered negative 4. Conservatively assume the smaller distance of the unit or curb Reactions Summary Long Side(e) Short Side(y) Per Side of Curb (Ib) (Ib) Unit to Curb Connection Maximum Tension 5796 3692 Maximum Compression 8041 5619 Maximum Shear 5299 6856 Curb to Surface Connection Maximum Tension 12518 5935 Maximum Compression 15420 9353 Maximum Shear 5673 7674 4/20/2021 ,, VAk CDI Curbs 21-OO1DA 7XXX Stock Update Curb Analysis Design S.Gardner Construction Engineering Services Unit to Curb Attachment 1/4-14 TEK Screw in Steel to Steel Shear Applied Shear V, 5796 lb Length of Unit Side L 102 in Section Properties Thickness of connecting material not in contact t1 0.079 in 14ga Thickness of connecting material in contact t2 0.052 in 18ga Diameter of Fastener d 0.25 in ESR-1976 Table 1 Area of fastener Ag=nrA2 0.049 in2 Clear distance in the direction of force to edge I, 0.75 in I„,;,, =3*d(ESR-1976 Section 4.1.3) Width of material resisting yielding ly=2*I, 1.5 in Assuming 45"stress distribution Material Properties Yield Stress of material Fy 33 ksi Allowable Loads Allowable Shear(Bearing)Capacity per bolt PNs/° 424 lb ESR-1976 Table 4 Allowable Shear(Fastener)Strength per bolt Pss/t1 990 lb ESR-1976 Table 5 Design Strength Ps/CI 424 lb ESR-1976 Section 4.1.3 Outputs Applied Shear V, 5795.939 lb Minimum#for Capacity N =Va/(Ps/D) 14 Screws Minimum even#for 12"spacing N=Even(L/12) 10 Screws UNIT TO CURB ATTACHMENT 1/4"TEK SCREW THRU UNIT BASE RAIL AND CURB(SEE STAMPED �� REPORT FOR DETAILS) N. UNIT BASE RAIL CURB VAK Construction Engineering Services,LLC 4/20/2021 f CDI Curbs 21-001 DA j VA K 7XXX Stock Update r. Curb Analysis Design S.Gardner Construction Engineering Services Unit to Curb Attachment 1/4-14 TEK Screw in Steel to Steel Shear Applied Shear V, 3692 lb Length of Unit Side L 48.875 in Section Properties Thickness of connecting material not in contact t1 0.079 in 14go Thickness of connecting material in contact t2 0.052 in 18ga Diameter of Fastener d 0.25 in ESR-1976 Table 1 Area of fastener Ag=nr^2 0.049 in2 Clear distance in the direction of force to edge I, 0.75 in /",;,, =3*d(ESR-1976 Section 4.1.3) Width of material resisting yielding I.=2*I 1.5 in Assuming 45°stress distribution Material Properties Yield Stress of material Fg 33 ksi Allowable Loads Allowable Shear(Bearing)Capacity per bolt PNS/Cl 424 lb ESR-1976 Table 4 Allowable Shear(Fastener)Strength per bolt Ps5/0 990 lb ESR-1976 Table 5 Design Strength PS/Cl 424 lb ESR-1976 Section 4.1.3 Outputs Applied Shear V, 3691.652 lb Minimum#for Capacity N=Va/(P5/0) 9 Screws Minimum even#for 12"spacing N=Even(L/12) 6 Screws UNIT TO CURB ATTACHMENT 1/4'TEK SCREW THRU UNIT BASE RAIL AND CURB(SEE STAMPED REPORT FOR DETAILS) UNIT BASE RAIL CURB VAK Construction Engineering Services, LLC 4/20/2021 CDI Curbs 21-001DA VA E[ 7XXX Stock Update Curb Analysis and Design S. Gardner _ Isolator Spring Check Construction Engineering Services JQA Spring Isolator Check Long Short Long Short Long Short Maximum Tension 5796 3692 Vert 1660 1660 N req 4 3 Maximum Compression 8041 5619 Vert 1660 1660 N req 5 4 Maximum Shear* 5299 6856 Horiz 800 S00 N req 7 9 *Shear resisted by all isolators. JQB Spring Isolator Check Long Short Long Short Long Short Maximum Tension 5796 3692 Vert 1600 1600 N req 4 3 Maximum Compression 8041 5619 Vert 1600 1600 N req 6 4 Maximum Shear* 5299 6856 Horiz 1000 1000 N req 6 7 *Shear resisted by all isolators. VAK Construction Engineering Services,LLC 4/20/2021 CDI Curbs 21-0O1DA• VA K 7XXX Stock Update Curb Analysis and Design S.Gardner Curb Box Section Spanning Isolator Springs Construction Engineering Services Isolation Curb Top in Bending Section Properties Thickness of steel t 0.108 in AISC Table 1-12 Width of member b 1.563 in Height of member d 7.5 in Area Ag 1.91 in2 S 308 in3 Z 411 in3 Applied Demand Overall Member Length L 102 in Number of Springs N,,„m„ 6 Spans 5 Span Length I 1.700 ft Applied Vertical Force(Tension or Shear) P 8.041 K Applied Distributed Load w=P/L 0.946 K/ft Applied Moment Ma=wl^2/8 0.34 K-ft Uniform load over simple span Applied Shear Va=wl/2 0.80 K Material Properties and S.F. Yield Strength Fy 33 Ksi Modulus of Elasticity E 29000 Ksi Safety Factor O 1.67 Width to Thickness Ratio b/t 14.47 Section 84.1 1.12VE/Fy Ap 33.20 if b/t< Xp member is compact 1.40VE/Fy A, 41.50 if b/t<A, member is non-compact Compact If bit.> A, member is slender VAK Construction Engineering Services,LLC 4/20/2021 vw, • CDI Curbs 21-001DA VA K 7XXX Stock Update Curb Analysis and Design S.Gardner A Curb Box Section Spanning Isolator Springs Construction Engineering Services Available Strength(Minor Axis) Yielding Mn=Mp=FyZ F7-1 Fy 33 Ksi Z 4.11 in3 Mp 135.7 K-in Flange Local Buckling b/t< Ao member is compact FLB does not apply b/t<A, member is non-compact M„=Mp(Mp F,5)(3.57(b/tf)(VF9/E)-4)5 Mp F7-2 Mp 136 Ksl 0.22137 Mn 212 Ksi Mn 136 Ksl b/t> Ar member is slender M„=F5Se F7-3 Effective section modulus from be be=1.92tfV(E/Fy)(1-(0.38/(b/tf))J(E/Fy))<b tf 0.108 in E/Fy 878.8 b/tf 14.47 be 1.36 in be 1.36 SQ=(bd3-b1d13)/6d Table 17-27 b 1.36 in d 7.5 in bi 1.14 in dl 7.28 in Se 2.93 in3 Mn 96.6 K-in FLB Does Not Apply Web Local Buckling b/t<Ap member is compact FLB does not apply b/t<A, member is non-compact Mn=Mp-(Mp-Fy5)(0.305(h/tw)(1/Fy/E)-0.738)SMp Mp 135.7 K-in Fy 33 Ksi S 3.08 in3 h 7.28 in tw 0.108 in JFy/E 0.034 Mn 137.2 K-in Mn 135.7 K-in Nominal Flexural Strength Mn 135.7 K-in Check Mn 135.7 K-in 0 1.67 Mn/0 81.3 K-in Ma 4.1 K-in DR 0.05 Okay VAK Construction Engineering Services,LLC 4/20/2021 CD!Curbs 21-001DA• VA K 7XXX Stock Update Curb Analysis and Design S.Gardner •y Curb Box Section Spanning Isolator Springs Construction Engineering Services Isolation Curb Top in Shear Section Properties Thickness of steel t,t„ 0.108 in Width of member b 1.563 in Height of member d 7.50 in S 3.08 in3 Z 4.11 in3 Other Applied Force Va 0.80 K Yield Strength Fy 33 Ksi Modulus of Elasticity E 29000 Ksi Safety Factor 0 1.67 Secondary Dimensions Width resisting the shear force h=b-3t 1.24 in Area Aw=2ht 0.27 in2 kv 5 Web Shear Coefficient h/tw 11.47 1.10VkvE/Fy 72.92 1.37VkvE/Fy 90.81 h/tw<1.10VkvE/Fy Cv 1 A/SC G2-3 1.1011kvE/Fy a h/hv 5 1.37VkvE/Fy Cv=(1.103/kvE/Fy)/(h/tw) Cv 6.4 G2-4 h/tw>1.37VkvE/Fy Cv=(1.51kvE)/((h/tw)2Fy) Cv 50.5 G2-5 Cv 1 Available Strength Shear Strength V„=0.6FyAWCV G2-1 Fy 33 ksi Aw 0.27 in' Cv 1 Vn 5.30 K Check Vn 5.30 K 0 1.67 Vn/O 3.17 K Va 0.80 K DR 0.25 Okay VAK Construction Engineering Services,LLC 4/20/2021 411D- CD!Curbs 21-001 DA 7XXX Stock Update Construction Engineering Services Curb Analysis and Design S.Gardner Isolation Spring Support in Compression IAISC 16th Ed.-Design of Members for Compression(E7.Members with Slender Elements) Applied Compressive Load P=C x5/8 9.64 K Height of Member L 36.25 in Section Properties Height of member d 1.5 in AISC Table 1-12 Width or diameter of member b 6 in Thickness of member t 0.079 in Area Ag 0.699 in2 Bracing conditions K 0.65 AISC Table C-A-7.1 Radius of gyration r 0.417 Material Properties&S.F. Yield Strength Fy 33 Ksi Modulus of Elasticity E 29000 Ksi Safety Factor ❑ 1.67 Compression Member Width to Thickness Ratio b/t 75.95 AISC Table 84.1a Oft 75.95 Flanges of I-shapes,plates from I-shapes,fla 0.56VE/Fy A, 16.601 If bit> A,member is slender Flanges of tees Slender Q=1 for Non-Slender Elements K =4/Vh/tw K, 0.92 Flanges and projections of built up I-shapes 0.64VEK,/Fy A, 0.02 Slender Legs of angles 0.45VE/Fy A, 13.34 Slender Stems of tees 0.75VE/Fy A, 22.23 Slender Webs of doubly symmetric I shapes and cha 1.49VE/Fy A, 44.17 Slender HSS and boxes 1.40VE/Fy Ar 41.50 Slender Round HSS 0.11E/Fy A, 96.67 Non-Slender VAK Construction Engineering Services,LLC 4/20/2021 CDI Curbs 21-001DA 7XXX Stock Update • Construction Engineering Services Curb Analysis and Design S.Gardner Isolation Spring Support in Compression Slender Unstiffened Elements b/t 75.95 VE/Fy 29.64 Fy 33 Ksi E 29000 Ksi 0.92 VEkJFy 28.40 a) Flanges,angles,plates projecting from rolled columns b/t 75.95 0.56VE/Fy 16.60 1.03VE/Fy 30.53 b/t<0.56VE/Fy Q,=1.0 Q, 1 0.56VE/Fy<b/t<1.03VE/Fy Q =1.415-0.74(b/t)JFy/E Q, -1664.67 b/t 21.03VE/Fy • =0.69E/(Fy(b/t)2) Q, 0.105 0.105 b) Flanges,angles,plates projecting from I-shaped columns b/t 75.95 0.64VEKc/Fy 18.18 1.17VEKc/Fy 33.23 b/t<0.64VEKJFy Q,=1.0 Q, 1 0.64VEKc/Fy<b/t<1.17JEKc/Fy Qs=1.415-0.65(b/t)VFy/Ekc Qs -0.323 b/t>1.17VEKc/Fy Q,=0.90EKJ(Fy(b/t)2) Q, 0.126 0.126 c) For single angles b/t 75.95 0.45VE/Fy 13.34 0.91VE/Fy 26.98 b/t<0.45VE/F, Qs=1.0 as 1 0.45VE/Fy<b/t<0.91VE/Fy Q,=1.34-0.76(b/t)VFy/E Q, -0.61 b/t>0.91VE/Fy Qs=0.53E/(Fy(b/t)2) as 0.081 0.081 d) For stems of tees b/t 75.95 0.75VE/Fy 22.23 1.03VE/Fy 30.53 d/t<0.75VE/Fy Q,=1.0 Q, 1 0.75JE/Fy<d/t 5 1.03VE/Fy C�=1.908-1.22(d/t)VFy/E Q, -1.22 d/t>1.031/E/Fy Cts=0.69E/(Fy(d/t)2) C!, 0.105 0.105 VAK Construction Engineering Services,LLC 4/20/2021 • CDI Curbs 21-001 DA 7XXX Stock Update Construction Engineering Services Curb Analysis and Design S.Gardner Isolation Spring Support in Compression Compressive Strength Effective Slenderness Ratio on a corner KL/r 56.545 Elastic Buckling Stress Fe=n2E/UKL/r)2) E3-4 KL/r 56.55 E 29000 Ksi Fe 89.43 Ksi Critical Stress Q 0.081 4.71E/QFy 491.4 QFy/Fe 0.030 Inelastic Buckling KL/r 5 4.71VQE/Fy or QFy/Fe<_2.25 Fcr=[0.658^(QFy/Fe)]Fy 32.59 Ksi E3-2 KL/r>4.71VQE/Fy or QFy/Fe>2.25 Fcr=0.877Fe 78.43 Ksi E3-3 Fcr 32.59 Ksi Nominal Compressive Strength Pn=FcrAg E3-1 Fcr 32.591 Ksi Ag 0.70 Pn 22.77 K Available Compressive Strength Pn/0 0 1.67 Pn 22.765 K Pn/0 13.63 K Check Pn/0>C Pn/0 13.63 K C 9.64 K DR 0.71 Column Okay? Okay VAK Construction Engineering Services,LLC 4/20/2021 } VA k CDI Curbs 21-001DA 7XXX Stock Update 4 Curb Analysis and Design S. Gardner Construction Engineering Services Curb Flange in Bending AISC 16th Ed.-Design of Members for Flexure(F11. Rectangular Bars and Rounds) Value Units Reference/Notes Inputs Applied Load Applied Tension Pa 12.518 K Applied Moment Ma = Pa*L_b 7.82 K-in Table 3-23 Section Properties Thickness of steel d 0.158 in Width of Steel b 82.500 in Radius of gyration r=d/V12 0.046 in Table 17-27 Area Ag= b*d 13.04 in2 Table 17-27 Moment of Inertia I = bdA3/12 0.027 in4 Distance from fastener to curb wall L_b 0.625 in Material Properties Yield Strength Fy 33 Ksi Modulus of Elasticity E 29000 Ksi Available Strength(Minor Axis) Check limit state of yielding L_b 0.625 in d 0.158 in t=b 82.500 in E 29000 Ksi Fy 33 Ksi Lbdlt2 1.45E-0511 0.08E/Fy 70.30 If Lbd/t2<_0.08E/Fy,LTB does not apply LTB Does not Apply Section F11.2 F11.1.Nominal Flexural Strength(Yielding) Sx=bdA2/6 0.34 in'3 Fy 33 Ksi My 11.33 K-in Z 0.51 inA3 Mp 16.99 K-in 1.6My 18.12 K-in Mn=Mp=FyZ<1.6FySx 16.99 K-in Eq F11-1 Check Safety Factor fl 1.67 F1.a Mn/fl 10.17 K-in Ma 7.82 K-in DR=Ma/(Mn/Q) 0.77 Okay VAK Construction Engineering Services,LLC 4/20/2021 • COI Curbs 21-001 DA VA 1[ 7XXX Stock Update Curb Analysis and Design S.Gardner _ Curb to Roof Fastener Construction Engineering Services AISC 16th Ed.-Design of Connections(13.Bolts and Threaded Parts) Number of Fasteners N 10 Applied Tension T 12518 lbs Applied Shear V 7674 lbs Length of Curb Flange L 102 in Section Properties Bolt Type 1/2"0 A307 Nominal diameter of bolt d 0.5 in Nominal unthreaded body area of bolt Ab 0.20 in2 AISC Table 7-17(Gross Bolt Area) Nominal bolt area A 0.142 in2 Clear dist.to edge or nearest bolt Ic 1 in Thickness of connected material t 0.079 in Material Properties and S.F. Nominal Tensile Stress Fnt 45 Ksi AISC-14 Table 3.2 Nominal Shear Stress Fnv 24 Ksi AISC-14 Table 3.3 Required Shear Stress per bolt fry 3.91 Ksi Required Tensile Stress per bolt fit 6.38 Ksi Specified min.tensile str.of conn.material Fu 58 Ksi Table 2-4 Safety Factor D 2 Combined Tension&Shear in Bearing Type Connections Available Tensile Strength Rn=F'ntAb 13-2 F'nt=13Fnt-(SUFnt/Fnv)Frv5Fnt J3-3b Fnt 45.0 Ksi F'nt 43.8 Fnv 24 Ksi fry 3.91 Ksi 2 F'nt 43.8364 Ksi F'nt within limits Ab 0.20 in2 Available tensile strength Rn 4.30-K/bolt Bearing Check '" Rn=1.51ctfu<3.0dtFu J3-6b Clear dist.to edge or nearest bolt Ic 1 in STEEL ATTACHMENT Thickness of connected material t 0.079 in Fu 58 Ksi d 0.5 in 1.5lctFu 6.87 awAssear 3.odtFu 6.87 I .im rsa"ca.vuaAr, irs w sag •nr�oro Rn 3.44 K/hole �'T WPM�F`o" 52i.omaw 11E xCEOS Check Required Tensile Stress frt 32502 lb Available tensile strength per fastener Rn 3437 lb/bolt STEss.«PM)* ElY OTHERS Minimum#for Capacity N=Va/(Ps/D) 10 Bolts Minimum#for 12"spacing N=Even(L/12) 10 Bolts VAK Construction Engineering Services,LLC 4/20/2021 iTh' COI Curbs 21-001AA . VA K 7/00(Stock Update Curb Analysis and Design S.Gardner `J` _ Curb to Roof Fastener Construction Engineering Services AISC 16th Ed.-Design of Connections(13.Bolts and Threaded Parts) Number of Fasteners N 8 Applied Tension T 5935 lbs Applied Shear V 5673 lbs Length of Curb Flange L 48.875 in Section Properties _. _ Bolt Type 1/2"0 A307 Nominal diameter of bolt d 0.5 in Nominal unthreaded body area of bolt Ab 0.20 in2 AISC Table 7-17(Gross Bolt Area) Nominal bolt area A 0.142 in2 Clear dist.to edge or nearest bolt Ic 1 in Thickness of connected material t 0.079 in Material Properties and S.F. Nominal Tensile Stress Fnt 45 Ksi AISC-14 Table 3.2 Nominal Shear Stress Fnv 24 Ksi AISC-14 Table 3.3 Required Shear Stress per bolt fry 3.61 Ksi Required Tensile Stress per bolt frt 3.78 Ksi Specified min.tensile str.of conn.material Fu 58 Ksi Table 2-4 Safety Factor t2 2 Combined Tension&Shear in Bearing Type Connections Available Tensile Strength Rn=F'ntAb 13-2 F'nt=1.3Fnt-(flFnt/Fnv)Frv5Fnt 13-3b Fnt 45.0 Ksi F'nt 45.0 Fnv 24 Ksi fry 3.61 Ksi CI 2 F'nt 44.9507 Ksi F'nt within limits Ab 0.20 in2 Available tensile strength Rn 4.41 K/bolt Bearing Check Rn=1.5lctFu S 3.0dtFu 13-6b Clear dist.to edge or nearest bolt Ic 1 in STEEL ATTACHMENT Thickness of connected material t 0.079 in Fu 58 Ksi d 0.5 in 1.5IctFu 6.87 a.®waaeEr 3.0dtFu 6.87 Ma "n "bro Rn 3.44 K/hole SIEVING8Larifp"g °5w AWN nFrrx sta�u LEM DECK Check ^ ? ,,6 1,,, Required Tensile Stress frt 19262 lb Available tensile strength per fastener Rn 3437 lb/bolt eroTIERS �s"pO i Minimum#for Capacity N=Va/(Ps/D) 6 Bolts I Minimum#for 12"spacing N=Even(02) 6 Bolts VAK Construction Engineering Services,LLC 4/20/2021 • CDI Curbs 21-001DA VAK 7XXX Stock Update ! Curb Design and Analysis S.Gardner Curb to Roof Fastener Construction Engineering Services NDS 2016-11.4 Combined Lateral and Withdrawal Loads Number of Fasteners L 16 Applied Tension T 12518 lb Applied Shear V 7674 lb Screw Porpertles Lag Screw Type 1/4"0 Wood Screw Diameter of screw D 0.25 in Embedment p 3.5 in Loads "L '.: r: , � �x •' Number of Fasteners(Tension) N 16 Number of Fasteners(Shear) 32 Applied Withdrawal(Tension)Load 12517.87 lb Applied Lateral(Shear)Load 7673.932 lb Allowable Withdrawal(Tension)Load W 225 lb/in AIDS Table 11.2A Specific Gravity of Wood G 0.5 Table 11.3.2A Allowable Lateral(Shear)Load Z 116 lb Table IIM Side Member Thickness t, 0.079 in Combined Lateral and Withdrawal Loads Applied Load Tension per fastener w 782.4 lb Shear per fastener z 239.8 lb Angle bet.wood surf.&dir.of applied load a 73.0 deg Resultant Applied Load z', 818.3 lb Withdrawal Design Value " W 225 lb/in CD 1.6 Table 2.3.2 CM 1.0 C 1.0 Cg 1.0 Cee 1.0 Cdi 1.0 Ct„ 1.0 W' 360 lb/in Table 10.3.1 WOOD ATTACHMENT Shear Design Value Z 116 lb CD 1.6 CUPS AMMO'— CM 1.0 Cr EOLIIVALENT 1.0 [awlr pnsecm CRBeA'£FIANCE Cg 1.0 �f Ceg 1.0 31 1T1— NI asap Cd; 1.0 144 Cr„ 1.0 Z' 185.6 I b Table 10.3.1 Combined Design Value Z'u=((W'p)Z')/((W'p)cos'a+Z'sin'a) Eq.11.4-1 W' 3601b p 3.5 in Z' 185.6 lb a 73.0 deg Z.n(perpendicular] 841.6 lb Okay 0.97 VAK Construction Engineering Services,LLC 4/20/2021 CDI Curbs 21-001-DA VA K 7XXX Stock Update Curb Design and Analysis S.Gardner Curb to Roof Fastener Construction Engineering Services NDS 2016-11.4 Combined Lateral and Withdrawal Loads , Number of Fasteners L 12 Applied Tension T 5935 lb Applied Shear V 5673 lb Screw Porperties Lag Screw Type 1/4"0 Wood Screw Diameter of screw D 0.25 in Embedment p 3.5 in Loads Number of Fasteners(Tension) N 12 Number of Fasteners(Shear) 24 Applied Withdrawal(Tension)Load 5934.71 lb Applied Lateral(Shear)Load 5672.646 lb Allowable Withdrawal(Tension)Load W 225 lb/in NOS Table 11.2A Specific Gravity of Wood G 0.5 Table 11.3.2A Allowable Lateral(Shear)Load Z 116 lb Table ISM Side Member Thickness t, 0.079 in Combined Lateral and Withdrawal Loads Applied Load Tension per fastener w 494.6 lb Shear per fastener z 236.4 lb Angle bet.wood surf.&dir.of applied load a 64.5 deg Resultant Applied Load z'a 548.1 lb Withdrawal Design Value W 225 lb/in Co 1.6 Table 2.3.2 CM 1.0 Ct 1.0 Cs 1.0 Cn 1.0 Cal 1.0 C,n 1.0 W' 360 lb/in Table 10.3.1 WOOD ATTACHMENT Shear Design Value Z 116 1b CD 1.6 0,®.SSDAIR...__ CM 1.0 W-WSMOM SCREWSCDDODIV C, 1.0 MAXI ACED ox CUPS BASE RANGE C6 1.0 Cq 1.0 Cdi 1.0 s Mil Cm 1.0 Z' 185.6 lb Table 10.3.1 Combined Design Value Zia=(EW'p)Z')/((W'p)cosza+Z'sin'a) Eq.11.4-1 W' 360 lb p 3.5 in Z' 185.6 lb a 64.5 deg Z'y(yirpendkylar) 606.8 lb Okay 0.90 VAK Construction Engineering Services,LLC 4/20/2021 SIMPSON Anchor DesignerThl Company: VAK Engineering Date: 4/15/2021 Engineer: S.Gardner Page: 1/6 Strong-Tie Software Project: 20-001DA Version 2.6.6794.0 Address: 8285 SW Nimbus Ave. 104 Beaverton, OR Phone: (503)718-5999 E-mail: sgardner@VAKEngineering.com 1.Project information Customer company:COI Curbs Project description: Customer contact name: Location: Customer e-mail: Fastening description: Comment: 2.Input Data&Anchor Parameters General Base Material Design method:ACl 318-14 Concrete:Normal-weight Units:Imperial units Concrete thickness,h(inch):6.00 State:Cracked Anchor Information: Compressive strength,Pc(psi):3000 Anchor type:Torque controlled expansion anchor 4 .v: 1.0 Material:Carbon Steel Reinforcement condition:B tension,B shear Diameter(Inch):0.500 Supplemental reinforcement:Not applicable Nominal Embedment depth(inch):3.000 Reinforcement provided at corners: No Effective Embedment depth,he(inch):2.500 Ignore concrete breakout in tension:No Code report:ICC-ES ESR-3037 Ignore concrete breakout In shear:No Anchor category:1 Ignore 6do requirement:Not applicable Anchor ductility:Yes Build-up grout pad:No hmin(inch):4.83 cep(inch):6.72 Base Plate Corm(inch):4.00 Length x Width x Thickness(inch):54.88 x 27.00 x 0.08 Shan(inch):4.00 Recommended Anchor Anchor Name:Strong-Bolt®2-1/2"0 CS Strong-Bolt 2,hnom:3"(76mm) Code Report:ICC-ES ESR-3037 1111011111111111111/111111111.11 Input data and results must be checked for agreement with the existing circumstances,the standards and guidelines must be checked for plausibility. Simpson Strong-Tie Company Inc. 5956 W.Las Positas Boulevard Pleasanton,CA 94588 Phone:925.560.9000 Fax:925.847.3871 www.strongtie.com SIMPSON Anchor DesignerTM Company: VAK Engineering Date: 4/15/2021 Engineer: S.Gardner Page: 2/6 StrongTie Software Project: 20-001DA Version 2.6.6794.0 Address: 8285 SW Nimbus Ave. 104 Beaverton,OR Phone: (503)718-5999 E-mail: sgardner@VAKEngineering.com Load and Geometry Load factor source:ACI 318 Section 5.3 Load combination:not set Seismic design:Yes Anchors subjected to sustained tension:Not applicable Ductility section for tension:17.2.3.4.3(d)is satisfied Ductility section for shear:17.2.3.5.3(c)is satisfied Do factor:not set Apply entire shear load at front row:Yes Anchors only resisting wind and/or seismic loads:Yes Strength level loads: N.[lb]:0 V.[lb]:2361 V.%[lb]:0 M.[ft-lb]:0 M.[ft-lb]:27709 M.[ft-lb]:0 <Figure 1> 0 lb 0 ft-lb 0 lb 2361 I 27709 ft-lb 4 0 ft-lb Input data and results must be checked for agreement with the existing circumstances,the standards and guidelines must be checked for plausibility. Simpson Strong-Tie Company Inc. 5956 W.Las Positas Boulevard Pleasanton,CA 94588 Phone:925.560.9000 Fax:925.847.3871 www.strongtie.com • SIMPSON Anchor Designer TM Company: VAK Engineering Date: 4/15/2021 Engineer: S.Gardner Page: 3/6 Strong-Tie Software Project: 20-001DA Version 2.6.6794.0 Address: 8285 SW Nimbus Ave. 104 Beaverton, OR Phone: (503)718-5999 E-mail: sgardner@VAKEngineering.com <Figure 2> a'. Input data and results must be checked for agreement with the existing circumstances,the standards and guidelines must be checked for plausibility. Simpson Strong-Tie Company Inc. 5956 W.Las Positas Boulevard Pleasanton,CA 94588 Phone:925.560.9000 Fax:925.847.3871 www.strongtie.com SIMPSON Anchor Designer TM Company: VAK Engineering Date: 4/15/2021 Engineer: S.Gardner Page: 4/6 Strong-Tie Software Project: 20-001DA Version 2.6.6794.0 Address: 8285 SW Nimbus Ave.104 Beaverton,OR Phone: (503)718-5999 E-mail: sgardner©VAKEngineering.com 3.Resulting Anchor Forces Anchor Tension load, Shear load x, Shear load y, Shear load combined, Nua(Ib) Vuex(Ib) Vuay(Ib) -4(Vaax)2+(Vaayr(Ib) 1 1056.3 196.8 0.0 196.8 2 1056.3 196.8 0.0 196.8 3 1056.3 196.8 0.0 196.8 4 1056.3 196.8 0.0 196.8 5 1056.3 196.8 0.0 196.8 6 1056.3 196.8 0.0 196.8 7 0.0 196.8 0.0 196.8 8 0.0 196.8 0.0 196.8 9 0.0 196.8 0.0 196.8 10 0.0 196.8 0.0 196.8 11 0.0 196.8 0.0 196.8 12 0.0 196.8 0.0 196.8 Sum 6337.8 2361.0 0.0 2361.0 Maximum concrete compression strain(%a):0.02 <Figure 3> ' I°L'J'`o a°Il Maximum concrete compression stress(psi): 101 Resultant tension force(Ib):6338 Resultant compression force(Ib):6338 Eccentricity of resultant tension forces in x-axis,e'Nx(inch):0.00 Eccentricity of resultant tension forces in y-axis,e'Ny(inch):0.00 Y Eccentricity of resultant shear forces in x-axis,e'vx(inch):0.00 ` Eccentricity of resultant shear forces in y-axis,e'vy(inch):0.00 x , 121110 8; 4.Steel Strength of Anchor in Tension(Sec. 17.4.1) Naa(Ib) 95 ©Nxx(Ib) 12100 0.75 9075 5.Concrete Breakout Strength of Anchor in Tension(Sec.17.4,21 Nb=kcAaliTcharl 5(Eq. 17.4.2.2a) kc As Tc(psi) haf(in) Nb(Ib) 17.0 1.00 3000 2.500 3681 0.750Nme=0.750(ANc/ANm)Y'egWY'ed,NYo,N P.p,NNG(Sec.17.3.1 &Eq. 17.4.2.1b) Ate(in2) ANco(in2) ca,min(in) Va,.N Yfed,N YygN Pcp,N Nb(Ib) 0 0.750Nug(Ib) 243.75 56.25 18.00 1.000 1.000 1.00 1.000 3681 0.65 7775 6.Pullout Strength of Anchor in Tension(Sec.17.4.31 0.750Npn=0.75OYe,PAxNp(fc/2,500)"(Sec. 17.3.1,Eq. 17.4.3.1 &Code Report) Yfc,P Aa Np(Ib) lc(psi) n 0 0.750Np„(Ib) 1.0 1.00 3062 3000 0.50 0.65 1635 Input data and results must be checked for agreement with the existing circumstances,the standards and guidelines must be checked for plausibility. Simpson Strong-Tie Company Inc. 5956 W.Las Positas Boulevard Pleasanton,CA 94588 Phone:925.560.9000 Fax:925.847.3871 www.strongtie.com SIMPSON Anchor Designer TM Company: VAK Engineering Date: 4/15/2021 Engineer: S.Gardner Page: 5/6 -Tie Software Strong Project: 20-001DA Version 2.6.6794.0 Address: 8285 SW Nimbus Ave. 104 Beaverton,OR Phone: (503)718-5999 E-mail: sgardner@VAKEngineering.com 8. Steel Strength of Anchor in Shear(Sec.17.5.1) V.(Ib) 09iour 0 ggro,x0Vse(Ib) 6510 1.0 0.65 4232 9. Concrete Breakout Strength of Anchor in Shear(Sec. 17.5.2) Shear perpendicular to edge in x-direction: Vbx=minI7(/a/da)p2lidaAaJfcc015;9,1.a1"fcc015I(Eq. 17.5.2.2a&Eq. 17.5.2.2b) la(in) da(in) /1a Pc(psi) ca,(in) Vbx(Ib) 2.50 0.500 1.00 3000 12.00 15549 0Vcng =0(Avc/Avco)Y'ec,vY'edvY'gvY'n,vVbx(Sea 17.3.1 &Eq. 17.5.2.1b) Ave(in2) Avcc(in2) glob Y'edv Y'cV Y'n.v Vbx(Ib) 95 95Vcb9x(Ib) 366.00 648.00 1.000 1.000 1.000 1.732 15549 0.70 10648 Shear parallel to edge in x-direction: Vby=min17(le/d4°2dd vial fcCa11'55: 9281'fcca,l51 (Eq. 17.5.2.2a&Eq. 17.5.2.2b) /e(in) da(in) ,?a f c(psi) ca,(in) Vby(Ib) 2.50 0.500 1.00 3000 17.71 27878 0Vcb9x=0(2)(Avo/Avice)iv.,vY'ad,vY'c,v f'n,vVby(Sec. 17.3.1, 17.5.2.1(c)&Eq. 17.5.2.1 b) Avc(in2) Avco(in2) V'ecv Y'ed,v Y'c,v V'n,v Vby(Ib) 0 01.4b9x(Ib) 534.78 1411.40 1.000 1.000 1.000 2.104 27878 0.70 31117 10.Concrete Prvout Strength of Anchor in Shear(Sec.17.5.3) 0Vcp9=OkcpNco9=0kcp(ANc/ANco)Y'ec,NY'ed,NY,NY'cp,NNh(Sec. 17.3.1 &Eq. 17.5.3.1 b) kcp AN,(in2) ANco(in2) Y'ec,N Y'ed,N Y'c,N 'Ycp,N Nb(Ib) 0 0Vcpg(lb) 2.0 487.50 56.25 1.000 1.000 1.000 1.000 3681 0.70 44658 11.Results Interaction of Tensile and Shear Forces(Sec.17.6.) Tension Factored Load, N.(Ib) Design Strength,el%(Ib) Ratio Status Steel 1056 9075 0.12 Pass Concrete breakout 6338 7775 0.82 Pass(Governs) Pullout 1056 1635 0.65 Pass Shear Factored Load,V.(Ib) Design Strength,aVn(Ib) Ratio Status Steel 197 4232 0.05 Pass T Concrete breakout x+ 2361 10648 0.22 Pass(Governs) II Concrete breakout y- 394 31117 0.01 Pass(Governs) Pryout 2361 44658 0.05 Pass Interaction check N„a/ON„ Voa/0Vo Combined Ratio Permissible Status Sec. 17.6..1 0.82 0.00 81.5% 1.0 Pass 1/2"0 CS Strong-Bolt 2, hnom:3"(76mm)meets the selected design criteria. Input data and results must be checked for agreement with the existing circumstances,the standards and guidelines must be checked for plausibility. Simpson Strong-Tie Company Inc. 5956 W.Las Positas Boulevard Pleasanton,CA 94588 Phone:925.560.9000 Fax:925.847.3871 www.strongtie.com SIMPSON Anchor DesignerTM Company: VAK Engineering Date: 4/15/2021 S, il Engineer: S. Gardner Page: 6/6 tron..� e Software Project: 20-001 DA "�"�Y Version 2.6.6794.0 Address: 8285 SW Nimbus Ave. 104 Beaverton, OR Phone: (503)718-5999 E-mail: sgardner@VAKEngineering.com 12.Warnings -Per designer input,ductility requirements for tension have been determined to be satisfied—designer to verify. -Per designer input,ductility requirements for shear have been determined to be satisfied—designer to verify. -Designer must exercise own judgement to determine if this design is suitable. -Refer to manufacturer's product literature for hole cleaning and installation instructions. Input data and results must be checked for agreement with the existing circumstances,the standards and guidelines must be checked for plausibility. Simpson Strong-Tie Company Inc. 5956 W.Las Positas Boulevard Pleasanton,CA 94588 Phone:925.560.9000 Fax:925.847.3871 www.strongtie.com SIMPSON Anchor Designer TM Company: VAK Engineering Date: 4/15/2021 Engineer: S.Gardner Page: 1/6 Strong-Tie Software Project: 20-001DA Version 2.6.6794.0 Address: 8285 SW Nimbus Ave. 104 Beaverton,OR Phone: (503)718-5999 E-mail: sgardner@VAKEngineering.com 1.Proiect information Customer company:CDI Curbs Project description: Customer contact name: Location: Customer e-mail: Fastening description: Comment: 2.Input Data&Anchor Parameters General Base Material Design method:ACI 318-14 Concrete:Normal-weight Units:Imperial units Concrete thickness,h(inch):6.00 State:Cracked Anchor Information: Compressive strength,f.(psi):3000 Anchor type:Torque controlled expansion anchor 4"c,v: 1.0 Material:Carbon Steel Reinforcement condition:B tension,B shear Diameter(inch):0.500 Supplemental reinforcement:Not applicable Nominal Embedment depth(inch):3.000 Reinforcement provided at corners: No Effective Embedment depth,he(inch):2.500 Ignore concrete breakout in tension:No Code report: ICC-ES ESR-3037 Ignore concrete breakout in shear:No Anchor category: 1 Ignore 6do requirement:Not applicable Anchor ductility:Yes Build-up grout pad:No haft(inch):4.83 ca.(inch):6.72 Base Plate Cram(inch):4.00 Length x Width x Thickness(inch):108.00 x 18.29 x 0.08 Smm(inch):4.00 Recommended Anchor Anchor Name:Strong-Bolt®2-1/2"0 CS Strong-Bolt 2,hnom:3"(76mm) Code Report:ICC-ES ESR-3037 41avainsmage Input data and results must be checked for agreement with the existing circumstances,the standards and guidelines must be checked for plausibility. Simpson Strong-Tie Company Inc. 5956 W.Las Positas Boulevard Pleasanton,CA 94588 Phone:925.560.9000 Fax:925.847.3871 www.strongtie.com SIMPSON Anchor DesignerTM Company: VAK Engineering Date: 4/15/2021 Engineer: S. Gardner Page: 2/6 StrongTie Software Project: 20-001DA Version 2.6.6794.0 Address: 8285 SW Nimbus Ave. 104 Beaverton,OR Phone: (503)718-5999 E-mail: sgardner@VAKEngineering.com Load and Geometry Load factor source:ACI 318 Section 5.3 Load combination:not set Seismic design:Yes Anchors subjected to sustained tension:Not applicable Ductility section for tension:17.2.3.4.3(d)is satisfied Ductility section for shear:17.2.3.5.3(c)is satisfied no factor:not set Apply entire shear load at front row:Yes Anchors only resisting wind and/or seismic loads:Yes Strength level loads: Nu.[lb]:0 Vim[lb]:3935 Vuer[Ib]:0 Mua[ft-lb]:0 Muy[ft-lb]:35033 Mu:[ft-lb]:0 <Figure 1> 0 lb j .. 0ft-Ib Olb A I 35033 ft-lb 3935 lb ' iii 0 ft-lb Input data and results must be checked for agreement with the existing circumstances,the standards and guidelines must be checked for plausibility. Simpson Strong-Tie Company Inc. 5956 W.Las Positas Boulevard Pleasanton,CA 94588 Phone:925.560.9000 Fax:925.847.3871 www.strongtie.com SIMPSON Anchor Designer TM Company: VAK Engineering Date: 4/15/2021 Engineer: S. Gardner Page: 3/6 Strong-Tie Software Project: 20-001DA Version 2.6.6794.0 Address: 8285 SW Nimbus Ave. 104 Beaverton,OR Phone: (503)718-5999 E-mail: sgardner@VAKEngineering.com <Figure 2> Input data and results must be checked for agreement with the existing circumstances,the standards and guidelines must be checked for plausibility. • Simpson Strong-Tie Company Inc. 5956 W.Las Positas Boulevard Pleasanton,CA 94588 Phone:925.560.9000 Fax:925.847.3871 www.strongtie.com SIMPSON Anchor Designer TM Company: VAK Engineering Date: 4/15/2021 Software StrongTie Engineer: S. Gardner Page: 4/6 Project: 20-001 DA Version 2.6.6794.0 Address: 8285 SW Nimbus Ave. 104 Beaverton, OR a Phone: (503)718-5999 E-mail: sgardner@VAKEngineering.com 3.Resulting Anchor Forces Anchor Tension load, Shear load x, Shear load y, Shear load combined, N„e(Ib) V.(Ib) V„y(Ib) AVuxx)'+(V„er)2(Ib) 1 803.1 393.5 0.0 393.5 2 803.1 393.5 0.0 393.5 3 803.1 393.5 0.0 393.5 4 803.1 393.5 0.0 393.5 5 803.1 393.5 0.0 393.5 6 0.0 393.5 0.0 393.5 7 0.0 393.5 0.0 393.5 8 0.0 393.5 0.0 393.5 9 0.0 393.5 0.0 393.5 10 0.0 393.5 0.0 393.5 Sum 4015.4 3935.0 0.0 3935.0 Maximum concrete compression strain(%e): 0.01 <Figure 3> -1r:f1 Maximum concrete compression stress(psi):60 Resultant tension force(Ib):4015 Resultant compression force(Ib):4015 Eccentricity of resultant tension forces in x-axis,e'Nx(inch):0.00 Eccentricity of resultant tension forces in y-axis,e'ey(inch):0.00 Y Eccentricity of resultant shear forces in x-axis,e'vx(inch):0.00 Eccentricity of resultant shear forces in y-axis,e'vy(inch):0.00 K d4Pl 4.Steel Strength of Anchor in Tension(Sec.17.4.11 Nxa(Ib) 46 ONxs(Ib) 12100 0.75 9075 . 5.Concrete Breakout Strength of Anchor In Tension(Sec. 17.4.21 Nb=krAxli1'"her1 5(Eq. 17.4.2.2a) k" 2, re(psi) her(in) Nb(lb) 17.0 1.00 3000 2.500 3681 0.750Nebg=0.750(An x/ANm)T c,N F d,N y.NYrcp,NNb(Sec. 17.3.1 &Eq. 17.4.2.1 b) As,,(in2) ANco(in2) Cash(in) gjec,N Wed.N `1'c.N 'Pcp,N Nb(Ib) 0 0.750N.bg(lb) 176.25 56.25 18.00 1.000 1.000 1.00 1.000 3681 0.65 5622 6.Pullout Strength of Anchor in Tension(Sec.17.4.31 0.750Np"=0.750nPAaNp(Pc/2,500)"(Sec. 17.3.1,Eq. 17.4.3.1 &Code Report) 'Y"p da Np(Ib) r"(psi) n 0 0.750Np"(Ib) 1.0 1.00 3062 3000 0.50 0.65 1635 Input data and results must be checked for agreement with the existing circumstances,the standards and guidelines must be checked for plausibility. Simpson Strong-Tie Company Inc. 5956 W.Las Positas Boulevard Pleasanton,CA 94588 Phone:925.560.9000 Fax:925.847.3871 www.strongtie.com SIMPSON Anchor Designer TM Company: VAK Engineering Date: 4/15/2021 Engineer: S. Gardner Page: 5/6 Strong-Tie Software Project: 20-001DA Version 2.6.6794.0 Address: 8285 SW Nimbus Ave. 104 Beaverton, OR Phone: (503)718-5999 E-mail: sgardner@VAKEngineering.com 8.Steel Strength of Anchor in Shear(Sec.17.5.1) V.(Ib) rbwout 0 09roat0Vsa(Ib) 6510 1.0 0.65 4232 9.Concrete Breakout Strenath of Anchor in Shear(Sec.17.5.2) Shear perpendicular to edge in x-direction: Vbx=m in(7(le/de)°2y da lalf rccar1.5; 9AaJf cca11 5I(Eq. 17.5.2.2a&Eq. 17.5.2.2b) le(in) da(in) .i.e Pc(psi) cal(in) Vbx(Ib) 2.50 0.500 1.00 3000 12.00 15549 0Vcbgx=0(Avc/Avcc)Vacyy'ed,v'Yc,v'Y4vVbx(Sec. 17.3.1 & Eq. 17.5.2.1 b) Avc(in2) Avcc(in2) Yea,v 'f'etlV 'Ya,v Y'n,v Vb,(Ib) 0 0Vcbgx(Ib) 312.00 648.00 1.000 1.000 1.000 1.732 15549 0.70 9077 Shear parallel to edge in x-direction: Vby=min17(/e/da)02Jda7.aJPcce11.5;92,9NIPcca11.51(Eq. 17.5.2.2a&Eq. 17.5.2.2b) la(in) da(in) ,ta f (psi) cal(in) Vby(Ib) 2.50 0.500 1.00 3000 18.00 28566 0Vcbgx=0(2)(Avc/Avcp)Y`ec,v`Yed,v'Pc,v y'n,vVby(Sec. 17.3.1, 17.5.2.1(c)&Eq. 17.5.2.1 b) Avc(in2) Avcc(in2) '7'ec,v Wed,v Yc,v y'n,v Vby(Ib) 0 0Vcbgx(Ib) 540.00 1458.00 1.000 1.000 1.000 2.121 28566 0.70 31421 10.Concrete Pryout Strenath of Anchor in Shear(Sec.17.5.3) ¢V,pg=QlkcpNpbg=0kcp(ANc/ANco)Y'ec,N'Yad,N'Yc,N'Ycp,NNb(Sec. 17.3.1 &Eq. 17.5.3.1 b) kcp ANc(in2) ANco(in2) '7'ec,N Ped,N 'Io,N xcp,N Nb(Ib) 0 0Vcpg(Ib) 2.0 352.50 56.25 1.000 1.000 1.000 1.000 3681 0.70 32291 11.Results Interaction of Tensile and Shear Forces(Sec. R17.6) Tension Factored Load, N.(Ib) Design Strength, eN,,(Ib) Ratio Status Steel 803 9075 0.09 Pass Concrete breakout 4015 5622 0.71 Pass(Governs) Pullout 803 1635 0.49 Pass Shear Factored Load,V.(Ib) Design Strength,eV,(Ib) Ratio Status Steel 394 4232 0.09 Pass T Concrete breakout x+ 3935 9077 0.43 Pass(Governs) II Concrete breakout y+ 787 31421 0.03 Pass(Governs) Pryout 3935 32291 0.12 Pass Interaction check (Naa/*N45/3 (V a/014 a)5/3 Combined Ratio Permissible Status Sec. R17.6 0.57 0.25 81.9% 1.0 Pa ss 112"0 CS Strong-Bolt 2,hnom:3"(76mm)meets the selected design criteria. Input data and results must be checked for agreement with the existing circumstances,the standards and guidelines must be checked for plausibility. Simpson Strong-Tie Company Inc. 5956 W.Las Positas Boulevard Pleasanton,CA 94588 Phone:925.560.9000 Fax:925.847.3871 www.strongtie.com SIMPSON Anchor Designer TM Company: VAK Engineering Date: 4/15/2021 Engineer: S. Gardner Page: 6/6 Strong'-rl ie Software Project: 20-001 DA 171ri-V+i�_i Version 2.6.6794.0 Address: 8285 SW Nimbus Ave. 104 Beaverton,OR a Phone: (503)718-5999 E-mail: sgardner@VAKEngineering.com 12.Warnings -Per designer input,ductility requirements for tension have been determined to be satisfied—designer to verify. -Per designer input,ductility requirements for shear have been determined to be satisfied—designer to verify. -Designer must exercise own judgement to determine if this design is suitable. -Refer to manufacturer's product literature for hole cleaning and installation instructions. Input data and results must be checked for agreement with the existing circumstances,the standards and guidelines must be checked for plausibility. Simpson Strong-Tie Company Inc. 5956 W.Las Positas Boulevard Pleasanton,CA 94588 Phone:925.560.9000 Fax:925.847.3871 www.strongtie.com Technical Data Sheet for Rebel 7-15 - heat wheel- heavy Job Information Technical Data Sheet . Job Name curb weights Date Submitted By Software Version 07.00 Unit Tag Rebel 7-15-heat wheel-heavy Unit Overview Model Number Voltage Design Cooling AHRI360 Standard Efficiency ASHRAE 90.1 V/Hz/Phase Capacity EER IEER 8tu/hr ASHRAE 90.1-2016 DP5015A 460/60/3 178435 10.7 16.4 compliant Unit Model Number: DPS015A Model Type: Heat Pump Heat Type: Gas Energy Recovery: ERW-Med Cab-Econ:2835 cfm max, 100%OA: 5145 cfm max Application: Variable Air Volume,Single Zone Controls: Microtech III Outside Air: 0-100%Economizer with Comparative Enthalpy Control Altitude: 0 ft Approval cETLus Physical Dimensions and Weight Length Height Width Weight 111.0 in 56.8 in 96.5 in 2995 lb Corner Weights Ll L2 L3 L4 484 lb 477 lb 1010 lb 1024 lb Construction Exterior Insulation and Liners Air Opening Location Return Supply Painted Galvanized Steel 1" Injected Foam, R 7, Bottom Bottom Galvanized Steel Liner Electrical Unit FLA MCA MROPD SCCR 34.7 A 37.9 A 50 A 5 kAIC Use only copper supply wires with ampacity based on 75°C conductor rating. Connections to Note: terminals must be made with copper lugs and copper wire. Return/Outside/Exhaust Air Outside Air Option Type Damper Pressure Drop Exhaust Air Type 0-100%Econ with Comparative Enthalpy Powered,Modulating with Building Control 0.20inHiO Pressure Control Job Number: GEIQ6J Page Prepared Date: 10/29/2018 Job Name: curb weights 68 of 108 www.DaikinApplied.com -, c CT d Ez d.,..smb�V. y. m W. LS. na F c A A I 5. asa n -. --- - -.i _..__ w m D c rn • v A ___,.., _._}_a. .,.— — -. N R Q oR" ro s -.' _--- --- rmw wgau-waa- N CC S fp DI f S fD fD PIAH VIEW•CG.CORNER WEIGHTS SERVICE CLEARANCE Nolan. (1)Center of Gredry Height=356 CIO (2)Total Weight=3661It, S n V if Rebel 7-15 - heat wheel- heavy 2995 co Rebel 7-15 heat wheel - light 2268 Rebel 7-15 standard- heavy 2745 Rebel 7-15 standard- light 1868 4' R.a unit weight range of 1800 to 3300 lbs 0 to m 1 0 co ~ Product Drawing, Unit Tag:Rebel 16-29 heat wheel-light Office:A LLC o [(Oregon) DA/K/N ' N ctjmNeme:c weights Sales [ a Industrial541 0- DP5O16A Product: U lV�� Isheetl of 1 Srak: lToleranceaJ-0.25 Dwg Units:in lmml www.mIn Version: 8 3 No lunge to this drawing maybe made unless approved in writing by Daikin Applied.Purchaser mast determine that the equipment is fit and sufficient for the job specifications. • AtKI'"' 7723 PHYSICAL DATA Table 2:Physical Data-Standard Units DPS 003 through 015 Model Small Cabinet Large Cabinet 003 004 005 006 007 010 012 015 Cooling only performance Gross Cooling capacity(tons) 3 4 5 6 7.5 10 12 15 Nominal airflow(cfm) 1125 1500 1875 2100 2450 3500 4200 5250 EER' 13.5 12.4 13.0 11.6 12.6 12.5 12.1 11.0 IEER'or SEER 16.9 17.0 18.5 19.8 20.6 19.4 18.5 18.0 Heat pump performance High Temperature Capacity @ 47°F(MBh) 32 43 54 64 78 105 134 164 COP @ 47°F or HSPF5 9.2 8.9 8.5 3.69 3.66 3.42 3.33 3.64 Low Temperature Capacity @ 17°F(MBh) 20 24 33 39 47 61.5 77 91 COP @ 17°F5 N/A N/A N/A 2.54 2.42 2.38 2.32 2.25 Electric heat performance Control Options 2/4/SCR 4 stage/SCR kW(low/medium/high heat) 6/12/18/30 18/36/54/72 Gas heating performance Input capacity(MBh) 80/120/160 200/300/400 Number of stages(staged option) 2 Turndown(Modulating options) 5:1 5:1, 10:1 Gas connection size(mpt) 1/2" 3/4" Steady state efficiency 80% Heating coil Type Hot Water Rows I FPI(high heat/low heat) (2/10)/(1/8) Face area(sq ft) 2.5 5.4 Compressors Quantity/Type (1)Inverter Scroll (1)Inverter Scroll,(1)Fixed Speed Scroll Number of stages Modulating Refrigerant R-410A Indoor coil Rows/FPI 3/16 4/16 4/14 4/14 3/15 4/15 4/15 6/12 Face area(sq ft) 4.8 4.8 6.0 6.0 14.0 15.4 15.4 15.4 Capacity control Electronic Expansion Valve(EEV) Outdoor coil Type:non-heat pump/heat pumps Aluminum Micro-channel/Copper tube-Aluminum fin Rows/FPI-heat pump 2/16 2/16 3/16 3/16 3/16 4/16 4/16 4/16 Rows/FPI-non-heat pump 1/21 1/21 3/16 3/16 1/21 1/21 4/16 1/21 Motor HP HP/Quantity 0.5/1 0.5/1 1.0/1 1.0/1 1.0/2 1.0/2 1.0/2 1.0/2 Fan Diameter(in)/Quantity 27/1 27/1 27/1 27/1 27/2 27/2 27/2 27/2 Indoor fan Type Centrifugal Airfoil(SWSI) Quantity/Diameter2 (1)12",(1)14",(1)16" (1)14",(1) (1)22" 16",(1)22" Quantity/Diameter3 (1)12",(1)14",(1)16" (1)14",(1)16",(1)22" Drive type Direct Drive Motor HP range 1.3/2.3/4.0 4.0/8.0 Hot gas reheat coil Coil Type Microchannel Control Type Modulating Temperature rise 20° Filters Type 2",4" Area(sq ft) 7.1 18 Qty.-size 4-16x16 6-18x24 NOTE:1.EER and IEER/SEER for Cooling Only VAV,460 volt unit 2.Mixed Outside Air and Relum Air units 3.100%Outside Air unit only 4.Heat pump performance for units with back up electric heat 5.HSPF for 3-5 ton units only 6.Size 12 non-heat pump models use copper tube aluminum fin www.DaikinApplied.com 25 CAT 256-11 • REBEL PACKAGED ROOFTOP 7723 DA/KIN PHYSICAL DATA , V Table 3:Physical Data-Unit Weights DPS 003 through 015 I I Small Cabinet Large Cabinet Model 003 004 005 006 007 010 012 015 Weight(lbs.) Base Weight' 1000 1000 1025 1058 1600 1600 1600 1763 Heat pump 1030 1030 1058 1058 1660 1660 1660 1823 Electric Heat 45 45 45 45 100 100 100 100 Hot Water 2 Row 11 11 11 16.5 30 30 30 30 Hot Water 1 Row 32 32 32 20 31 31 31 31 Gas Heat 75 75 63 93 186 186 186 186 Hot Gas Re-heat 8 8 12 12 28 31 31 31 Economizer 163 163 163 163 308 308 308 308 High capacity coil 105 105 105 105 215 215 215 215 Energy Wheel Weight Adds(lbs.) 100%OA 160 160 160 160 300 300 300 300 Mixed Air 175 175 175 175 250 250 250 250 1. Includes standard cooling coil Fan Weights(lbs.) 12 Inch(310 mm) 87 14 Inch(360 mm) 91 16 Inch(400 mm) 115 22 Inch(560 mm) 115 Curb Weights(lbs.) 14" 24" 003-006 156 230 007-015 200 295 Table 4:Refrigerant Charge Cooling Model Heat Pump Model Unit - 1 Size Standard Unit Standard Unit Standard Unit Standard Unit wl MHGRH wi MHGRH 3 10.5 12.9 12.0 14.4 4 11.1 13.5 12.6 15.0 5 15.3 18.2 16.8 19.7 6 15.3 18.2 16.8 19.7 7.5 11.0 17.3 26.0 31.2 10 34.0 39.8 40.0 45.8 12 34.0 39.8 40.0 45.8 15 37.0 43.8 42.0 47.8 CAT 256-11 • REBEL PACKAGED ROOFTOP 26 www.DaikinApplied.com - DIMENSIONAL DATA Figure 30:DPS 007-015, Gas Heat, Energy Recovery Gas Electric Heat,Hot Water Coils Size(tons) L Heat or Cooling Only _ 7-12 132 7 X1 Energy Recovery ------ 15 149.7 Economizer No Economizer, No Energy Recovery 2 4 ` t ,i sr,8 4k 1 , Mange s �,§CF yW r.rHy 7 �nr'.. ps� .r eza 2.99 r2i )17 5�9 i 3; 533 0 474 RAk.��� ,PFN R, - >95 53 >JB 205 ZRA/N593 /fE/GryT6B -..___. 4!. �ac<scaVNSzs ran, 'we, NOTE: 1. Recommended location for field-cut,side power opening 2. Only provided on 575 volt units 3. Not supplied on horizontal return or 100%OA units 4. Horizontal, above the roof, gas connection only www.DaikinApplied.com 39 CAT 256-11 • REBEL PACKAGED ROOFTOP DA/KIN DIMENSIONAL DATA . Figure 31: DPS 007-015, Hot Water Heat, Energy Recovery Gas Electric Heat,Hot Water Coils Size(tons) L Heat or Cooling Only 7-12 132.7 XEnergy Recovery — 15 -__- 149.7 _ ----- Economizer No Economizer, No Energy Recovery 2 r 'ANT 1/ r I�► T Mil I _1.1 'II _ I miiis [1` eM�., 526 299 / -Ilj:;-7 --_ L._1 Cottin>SER 579 I g 339 p 5E 95 436 205 250-._..___ 53 ---12g_. . .755 fa29 .` ---- 4)i _- '- ---111.p.._._ -- c __ _ _-- NOTE: 1. Recommended location for field-cut,side power opening 2. Only provided on 575 volt units 3. Not supplied on horizontal return or 100%OA units 4. Optional,field-cut, hot water entrance CAT 256-11 •REBEL PACKAGED ROOFTOP 40 www.DaikinApplied.com , ' `AITKIN DIMENSIONAL DATA Figure 32:DPS 007-015, Gas Heat, Economizer Gas Electric Heat,Hot Water Coils Size(tons) L Heat or Cooling Only -112.7 Energy Recovery 15 129.7 X Economizer No Economizer, No Energy Recovery 2 E:::› I'l 1 1 lint .,. . al ....,I 1 j "‘'tr ..c _ :f Ciy yfey M _ 71 //YUOi r{ J Y F[UC QT 0 ti,,,R --- - —31 a J39 o 07, Faiexemgy _.' t89 4105 Ps°.:._ S9 J3.s _. 1 41 rzr,4scav,v� es NriGy7ss taz9 _ -._loss--____ ttto _ NOTE: 1. Recommended location for Feld-cut,side power opening - __ __ 2.Only provided on 575 volt units 3. Not supplied on horizontal return units 4. Horizontal, above the roof,gas connection only www.DaikinApplied.com 41 CAT 256-11 • REBEL PACKAGED ROOFTOP F. DAIKIN DIMENSIONAL DATA Figure 33: DPS 007-015, 575 V, Hot Water Heat, Economizer Gas Electric Heat,Hot Water Coils Size(tons) L _ L Heat or Cooling Only --- 7-12 112.7 Energy Recovery 15 129.7 XEconomizer No Economizer, No Energy Recovery lie `/rili - . 4 ',NV' ' 55,8 t i e07T4 FOGE i-u p ® / 1Y izi I AIM 11j /, rl 4, '..':r .p. .cvc... . •III, / VIO 428 299 7 .., coNAsyseR 57,9 .788 oY3 474 ✓aRENIgy faa - - . 55 95 53 !38 205 51 ; :l2.9 ._f!F/GH755-- • g 4 67.12 NOTE: 1. Recommended location for field-cut,side power opening 2.Only provided on 575 volt units 3. Not supplied on horizontal return or 100%OA units 4.Optional,field-cut, hot water entrance CAT 256-11 • REBEL PACKAGED ROOFTOP 42 www.DaikinApplied.com . ! .''AIK/N DIMENSIONAL DATA Figure 34:DPS 007-015, 575 V, Gas Heat, Outside Hood Gas Electric Heat,Hot Water Coils Heat or Cooling Only Energy Recovery Economizer X No Economizer, No Energy Recovery 2 5 OA eOTidl FOyc 27.7 I� .W66 028 299 12) • 5 5] 579 f 339 c 4Lq orompEMRY 16.87 53 1.7-6 2'75 T393 66 l —--ass _ NOTE: 1. Recommended location for field-cut,side power opening Wee 2.Only provided on 575 volt units 3. Not supplied on horizontal return or 100%OA units 4. Horizontal,above the roof,gas connection only 5. Not provided on 100% Return Air units www.DaikinApplied.com 43 CAT 256-11 • REBEL PACKAGED ROOFTOP DAIKIN DIMENSIONAL DATA Figure 35:DPS 007-015, 575 v, Hot Water Heat, Outside Hood Gas Electric Heat,Hot Water Coils Heat or Cooling Only Energy Recovery Economizer X No Economizer, No Energy Recovery 4400),„ 2 ' -.... 4; IfOA IALE1 e MAIroEr 27.7 Al I am, .__-- 01.0 299 2 W n CON'0.tNseft 985 r 5Z9 F g 31 479 974 5'B9.5 135 2Q5 53 NelayT t S 594 ego— __ NOTE: 1. Recommended location for field-cut,side power opening fors,s 2. Only provided on 575 volt units 3. Not supplied on horizontal return or 100%OA units 4. Not provided on 100% Return Air units 5. Optional,field-cut, hot water entrance CAT 256-11 • REBEL PACKAGED ROOFTOP 44 www.DaikinApplied.com RECEIVED Fr DAIK1N JUN 2 0 2023 CITY OF TIGARD BUILDING DIVISION SUBMITTAL DATA for Hunter Davisson - Dartmouth Crossing Prepared for Ryan @ Hunter Davisson Prepared by Rob Grace 11/17/2021 Job Number: GQM31Z Page Prepared Date: 11/17/2021 Job Name: Hunter Davisson- Dartmouth 1 of 41 www.DaikinApplied.com Table of Contents Technical Data Sheet for HRU-1 3 Drawings(1)for HRU-1 8 Drawings(2)for HRU-1 9 Drawings(3)for HRU-1 10 7-15 DoorSwing With ERW_Drawing for HRU-1 11 Fan Curve-Supply for HRU-1 12 Fan Curve-Exhaust for HRU-1 13 Technical Data Sheet for HRU-2 14 Drawings(1)for HRU-2 19 Drawings(2)for HRU-2 20 Drawings(3)for HRU-2 21 7-15 DoorSwing With ERW_Drawing for HRU-2 22 Fan Curve-Supply for HRU-2 23 Fan Curve-Exhaust for HRU-2 24 Technical Data Sheet for HRU-3 25 Drawings(1)for HRU-3 30 Drawings(2)for HRU-3 31 Drawings(3)for HRU-3 32 7-15 DoorSwing With ERW_Drawing for HRU-3 33 Fan Curve-Supply for HRU-3 34 Fan Curve-Exhaust for HRU-3 35 Rebel Rooftop ECM Fan 36 Rebel Rooftop Energy Wheel Filtration 37 Rebel Rooftop Mist Eliminator 38 Rebel Rooftop MTIII DDC Controller 39 Job Number: GQM31Z Page Prepared Date: 11/17/2021 Job Name: Hunter Davisson-Dartmouth 2 of 41 www.DaikinApplied.com Technical Data Sheet for HRU-1 Job Information Technical Data Sheet 4111111111*.....:, aa► Job Name Hunter Davisson-Dartmouth Crossing " Date 11/17/2021 Submitted By Robert Grace Software Version 09.40 Unit Tag HRU-1 Unit Overview Model Number Voltage Design Cooling EER@95/75 EAT&200 CFM/ton ISMRE Per AHRI V/Hz/Phase Capacity EER IEER 920-2016 Btu/hr DPS007A 208/60/3 90546 12.6 Not Available ASHRAE 90.1-2016 compliant Unit Model Number: DPS007A Model Type: Heat Pump Heat Type: Electric Energy Recovery: ERW-Med Cab-Econ: 2835 cfm max, 100%OA: 5145 cfm max Application: Variable Air Volume,Single Zone(Mixed Air or 100%OA) Controls: Microtech III outside Air: 100%Outside Air Altitude: 0 ft Approval CETLus Physical Dimensions and Weight Length Height Width Weight 111.0 in 56.8 in 96.5 in 2486 lb 11 Corner Weights Li L2 L3 L4 464 lb 415 lb 759 lb 848 lb Construction Exterior Insulation and Liners Air Opening Location Return Supply Painted Galvanized Steel 1" Injected Foam, R-7, Bottom Bottom Galvanized Steel Liner Electrical Unit FLA MCA MROPD SCCR 92.1 A 107.6 A 110 A 5 kAIC Note: Use only copper supply wires with ampacity based on 75°C conductor rating. Connections to terminals must be made with copper lugs and copper wire. Job Number: GQM31Z Page Prepared Date: 11/17/2021 Job Name: Hunter Davisson-Dartmouth 3 of 41 www.DaikinApplied.com Technical Data Sheet for HRU-1 Return/Outside/Exhaust Air Outside Air Option Type Damper Pressure Drop Exhaust Air Type None 0.10 inH:o Powered, Modulating with Building Pressure Control Exhaust Fan Type Drive Type Wheel Diameter SWSI AF Direct Drive 18 in Motor (Qty)Horsepower Type Efficiency Full Load Current(Each) (1)4.0 HP ECM Premium 8.8 A Performance Air Flow External Static Pressure Fan Speed Brake Horsepower CFM inHzO RPM HP 2335 1.50 1481 1.25 Energy Recovery Design OA Volume Design Exhaust Volume Wheel Pressure Drop Motor HP Motor FLA 2850 CFM 2335 CFM 0.54 inHzO 0.17 HP 0.7 A Summer Conditions Temperature Recovered Effectiveness Outside Air Return Air Wheel Leaving Mixed Air Capacity Total Sensible Dry Bulb Wet Bulb Dry Bulb Wet Bulb Dry Bulb Wet Bulb Dry Bulb Wet Bulb Btu/hr "F ,F •F 'F 7 "F 7 "F 95.0 70.0 75.0 62.0 83.6 65.9 83.6 65.9 41718 60.27 69.83 Winter Conditions Temperature Recovered Effectiveness Outside Air Return Air Wheel Leaving Mixed Air Capacity Total Sensible Dry Bulb Wet Bulb Dry Bulb Wet Bulb Dry Bulb Wet Bulb Dry Bulb Wet Bulb Btu/hr •F •F •F •F "F =F -F `F 22.0 19.0 70.0 54.0 50.6 41.7 50.6 41.7 118328 71.23 72.71 Bypass Damper: No Energy Recovery Filters Quantity/Size Face Area Face Velocity Air Pressure Drop Efficiency Outdoor Exhaust Outdoor Exhaust Outdoor Exhaust Outdoor Exhaust ft' ft' ft/min ft/min inH:O inH2O 2 in. MERV 8 (3) 18 in.X 24 in. (3) 18 in.X 24 in. 9.0 9.0 316.7 259.4 0.12 0.08 Combined Efficiency Factor Application Specific CEF: 12.0 Filter Section Physical Type Quantity/Size Face Area Face Velocity Air Pressure Drop Combo 2"/4"rack with 6/18 in x 24 in x 2 in 18.0 ft' 158.3 ft/min 0.05 2" MERV 8 Job Number: GQM31Z Page Prepared Date: 11/17/2021 Job Name: Hunter Davisson-Dartmouth 4 of 41 www.DaikinApplied.com Technical Data Sheet for HRU-1 DX Cooling Coil Physical Coll Type Refrigerant Type Fins per Inch Rows Face Area Face Velocity Air Pressure Drain Pan drop Material Cu Tube/Al R410A 15 3 14.0 ftz 203.3 ft/min 0.12 inHxo Stainless Fin Steel Cooling Performance Capacity Indoor Air Temperature Ambient air Total Sensible Moisture Entering Leaving Temperature Btu/hr Btu/hr Removal Dry Bulb Wet Bulb Dry Bulb Wet Bulb Dewpoint °F lb/h °F °F °F °F 'F 90546 86587 2.9 83.6 65.9 55.8 55.6 55.5 95.0 Condensate Connection Size: 3/4 in. Male NPT Heating Performance Total Capacity Refrigerant Indoor Air Temperature Dry Bulb Ambient Air Btu/hr Type Entering Leaving Temperature °F °F °F 57359 R410A 50.6 69.0 23.0 Fan Section Fan Type Fan Wheel Diameter Fan Isolation SWSI AF 16 in None Performance Airflow Total Static Pressure Fan Speed Brake Horsepower Altitude 2850 CFM 2.6 inH:O 2047 rpm 1.74 HP 0 ft Motor Drive Type Horsepower Efficiency FLA Type ECM Motor 4.0 Premium 8.8A Direct Drive Electric Heat Section Physical Electrical Airflow Size Control FLA A 2850 CFM 18 kW SCR control 50.0 Performance Capacity Air Temperature Air Pressure Drop Btu/hr Entering Leaving inH2O 'F °F 61434 50.6 70.5 0.13 Unit Discharge Conditions AirTemperature Motor Heat Moisture Removal Unit Leaving Dry Bulb Unit Leaving Wet Bulb Unit Leaving Dewpoint Btu/hr lb/h 'F 'F 'F 5457 2.9 57.5 56.2 55.5 Minimum Airflows Fan Only Minimum Airflow Cooling Minimum Airflow Heating Minimum Airflow 940 CFM 1052 CFM 944 CFM Notes: Refer to fan curve for applicability of approximate airflows Job Number: GQM31Z Page Prepared Date: 11/17/2021 Job Name: Hunter Davisson -Dartmouth 5 of 41 www.DaikinApplied.com Technical Data Sheet for HRU-1 Condensing Section Compressor Type Quantity Refrigerant Charge Total Power Capacity Control Compressor Isolation lb Inverter Scroll 2 26.0 5.80 kw Mod Control with Rubber in Shear Inverter Compressor Compressor Amps: Compressor 1 11.9 A Compressor 2 8.6 A Condenser Coil Type Fins per Inch Fin Material Copper Tube 16 Aluminum Condenser Fan Motors Number of Motors Full Load Current(Total) 2 4.0 A Internal Pressure Drop Calculation External Static Pressure: 1.50 inHzO Filter: 0.05 inHzO Outside Air: 0.10 inHzO Energy Recovery: 0.66 inH2O DX Coil: 0.12 inHzO Electric Heat: 0.13 inHzO Total Static Pressure: 2.56 inHzO Sound Sound Power(db) Frequency 63 Hz 125 Hz 250 Hz S00 Hz 1 kHz 2 kHz 4 kHz 8 kHz Inlet 74 72 80 75 77 71 66 60 Discharge 74 75 83 80 83 77 74 68 Radiated 85 85 81 78 76 71 64 57 Options Unit Smoke Detectors: Return Air Smoke Detector Electrical Field Connection: Non-Fused Disconnect Switch Powered Receptacle: Unit powered 115V GFI outlet Power Options: Phase Failure Monitor Factory Installed Sensors Leaving Coil/Entering Fan Temperature Sensor Duct High Limit Switch Return Air Temperature Sensor Discharge Air Temperature sensor—Wired in unit,mounted in supply duct Outside Air Temperature Sensor Dirty Filter On/Off Switch Supply Fan Air Proving Via Modbus Building Static Pressure Sensor Supply Leaving Wheel Temperature Sensor Exhaust Leaving Wheel Temperature Sensor Job Number: GQM31Z Page Prepared Date: 11/17/2021 Job Name: Hunter Davisson -Dartmouth 6 of 41 www.DaikinApplied.com Technical Data Sheet for HRU-1 Warranty Parts: Standard One Year compressor: Standard One Year Notes Job Number: GQM31Z Page Prepared Date: 11/17/2021 Job Name: Hunter Davisson-Dartmouth 7 of 41 www.DaikinApplied.com v cr en as z z a e a fN .. M. Sn 0 C3 x A raw -----__i C Ill r N g .C. /A4.114 MEOOE a r Doi r -7 ., fu a. m 36.5 i ,,:r.,. ..._,I. i milliitaimi LIN 74 1 EN el.oAYER hE/cHT f0,o 3A 132.7 --y n O d R iNotes: v (1)Recommended location for optional field cut side power connection. i + Product Drawing Unit Tag:HRU-1 Sales Office:Oregon Air Reps(Portland) ,DAIK/N E, r Product: Project Name:Hunter Davisson-Dartmouth Sales Engineer:SalesEnglneer 1 N Model:DPSDO7A Nov.11,2021 I Ver/Rev: I Sheet:loft Scale:NTS I Tolerance:s- I www 130 aikinhonil Park Blvd.Minneapolis,MNn54s1 0 25' Osvg units:in(mini ww OaikinAoollM corn Software Version 09 40 3 0 3 r No change to this drawing may be made unless approved in writing by Dalian Applied.Purchaser must determine that the equipment is fit and sufficient for the job specifications. Drawings(2) for HRU-1 62.8 CONDENSER 96.5 0 33.9 POWER ENTRY 57.9 47.4 0 18.8 20.5 13.6 t 5.3 25.0 DRAIN 59.3 a HEIGHT 6.6 102.9 106.3 111.0 132.7 PLAN VIEW - OPENINGS & OVERALL Product Drawing Unit Tag: HRU-1 p DAM/AI Product: Project Name:Hunter Davisson- 13600Industrial Park Blvd.Minneapolis,MN 55441 Model:DPS007A Sales Office:Oregon Air Reps jPortland) www.DaikinAoolied.com Software Version:09.40 Sales Engineer:SalesEngineer Nov.17,2021 Ver/Rev: I Sheet 1 of 1 Scale:NTS Tolerance:./-0.25" Dwg Units:in(mm] No change to this drawing may be made unless approved in writing by Dalkin Applied. Purchaser must determine that the equipment is fit and sufficient for the job specifications. Job Number: GQM31Z Page Prepared Date: 11/17/2021 Job Name: Hunter Davisson-Dartmouth 9 of 41 www.DaikinApplied.com v T c m 2 2 L C 9 S S. ON -- 80.0 w xct o P �w Corner Weight L4-848 lb Corner Weight L3-759 Ib C 0 3 IL. 5. O o Co denser O a. 3 3 c 50.0 —se.p-- M S y�j5 m tfa a Enegy Recover! _ 6 d W a O 37.5 a o -0 VIII - ro F. N / \\-Corner Weight L2-415 lb Corner Weight L1-4641b a.o v a r 9 Y a o sz 4 i rt. 3 PLAN VIEW-CG,CORNER WEIGHTS,SERVICE CLEARANCE E Notes: 1 (1)Center of Gravity Height=25.7 3 (2)Total Weight=2486 lb t. = Y Product Drawing Unit Tau:HRU-1 Sales Office:Oregon Air Reps(Portland) ,DA/K/N r Product: Project Name:Hunter Davisson-Dartmouth Sales engineer.Salesengineer T. N s1 o Industrial dP corno Blvd.Minneapolis,V MNsin'441 09 0 Model:DP5007A Nov.1],2W1 I Ver/Ilev: I Sheet Soft Scale:NlS I Tolerence:+/-0.25' I Dwg Units:In y;yeee paikinAoelied Software Version�p96p 3 rs-e No change to this drawing may be made unless approved in writing by Daikin Applied.Purchaser must determine that the equipment is fit and sufficient for the job specifications. • S P V Z Z �'• Y C T S 0 0 S. co cm �w ri 7V /I a m X. lv 0\ 401 o `.c j w M O LI ii 77 IIs___._4201. —1925 ice.--__-r.2468 i H1150:—• 4217 50.80 9 II; n m 2. v N- A E 1 e. Y 3' l Product Drawing Unit Tag:HRU-1 Sales Office:Oregon Air Reps(Portland) w = - Product: Project Name:Hunter Davisson- Sales Engineer: ,DA/K/N D1 13600 Industrial Park Blvd.Minneapolis.MN 55441 ? o Model:DPS007A Nov.17,2021 I Ver/Rev: I Sheet:1 of 1 Scale:NTS I Tolerance:+/-O.2S" I Owg Units:In[mml www.DaikinApplied.corn Software Version:09.40 3 •N, No change to this drawing may be made unless approved in writing by Daikin Applied.Purchaser must determine that the equipment is fit and sufficient for the job specifications. • STA OARD CON.TRUCTN)NDETAIL °'-'v0100Txawx®°m Mal V1~wf REVISIONS DUCT FLEX CONNECTIONS PROVIDED BY OTHERS REV ECOE DESCRIPTION DALE APPROVED IX4 WOOD NAILER I RENAL DRAWHG I1/I/IS SIR SPRING ACCESS DOORS ARE GASKETED AND 2 UPDATED IBC,CBC 8 RIC 4115m SRP SCREWED ON FROM DRAWING GASKET MATERIAL PROVIDED FOR THE TOP OVERALL 14GA BOXED TOP FRAME PERIMETER(INCLUDING BRACES) HEIGHT 2S iM 281M 30114 161N SPRING PACKS MAY REQUIRE FIELD ADJUSTMENT BASE CURB HEIGHT 11 14 16 24 �\ RETURN (BY OTHERS) BASE MATERIAL GA /4 14 1d 19 /41 FULLY WELDED GALVANIZED(GAO)CONSTRUCTION CURB WEIGHT 454 4T0 510 550 ��. WEATHER SEAL BETWEEN UPPER&LOWER 11 `� RIGA DUCT BRACES SECTIONS PROWDED(BULS SEAL) r= G IFWI0\ OR ANCHORINGO , CURB TO R DRFFORSTEEL•CONCRETE I � OR WOOD,SEE DETAIL DRAWING"ROOF ANCHOR" SUPPLY FORM NO.SEISMIC-ATTACHMENTS % 441 I I I I I I Oi T \ `1` `�j} CURB BASE `` '� it O.M1 867/8" SPRING 1\ //� ? 7 14GA 3PRI EA \ 11�/ G CURB NOT ACCURATE - ADD 22 TO ,D III0 26 INCHES AND THE SUPPLY AND HEM BABE FLANGE RETURN WILL DISCHARGE / —22"—I HORIZONTALLY OUT OF THE CURB �357 " CURB WEIGHT APPROX. 850 LBS. 5934' 901/4' 1/4'TEK SCREWTHRU r---- UNIT BASE RAIL AND CURB_ �� PER STAMPED REPORT 561/4' —� 10512" S23/8' 2" 102'ID. 7 V 1' I 48 7/8"BASE CURB I.D. 212' u u __ I 11 CURB l BASE CURB+121/4 r �^• 1 T (38'MAX WIT PITCH)H I I \ I I DETAIL 1:1 BASE CURB I I SCALE HEIGHT T,err.aI SATE mu, CURB DESIGNED TO MEET SEISMIC 8 WIND LOAD REQUIREMENTS FOR mwSE mOB.F..,iax DF CRYSTAL ."ic, 4T8.16 - spa. 2018 1BC/ASCE 7-16,AND 2020 FBC FLORIDA BUILDING CODE 2019 CSC AN ou..x,nwLxc "®- 1 C7-00XX-7723 SEISMIC ISOLATION CURB -u WIND DESIGN:MAX BUILDING HEIGHT ULTIMATE DFACTOR=1.00 MAX i9°F4 TUMMY NAM2O21)12]9AM 201818LIASCE 7-16:MAX 185 MPH ULTIIMTE DESIGN WIND SPEED,RISK 30 ASSEMBLY m LTy 1) 1TMRTYLER Sr SW —"`¢ CATEGORY II,III,OR N BUILDING,EXPOSURE C CDI EIXRWEIL Mx SB3R =x•Ora>721 2 pQu�aVt.rno SEISMIC:04 200 MAX,IMPORTANCE FACTORIP=1.5 mnnw1cAr uuxa xenr®�' 2.r I�8 pN)n1-TRe1 122 I"w.I n P SICURBS CURB ADAPTERS1CX-XXXX-)DODI_CONFORMING\C1-XXXX-XXXX_ISO_CURBS_RAILSIC]-XLT(X-1%)DBC]LOXX-i]2N Fan Curve -Supply for HRU-1 Daikin Fan Selection . 2550 RPM 5.0 _ 2400 RPM • S 4.0 — z i I RPM \-.� N6666... -441111111N f 41111111114\ .. L. y 3.0 - y tsoa R 4. h a�A: N M— sso `20 iliw : , at200 RPM A •o :` ` 1.0 _ 00RP_AIIMIIIIW Gts. .,. : 4. :. . . . _ _800 RPM 0 • -$ '$J3 . • — RkA 0.0 - I I I 1 I I I 1 I I 1 I 1 I I I I 0.0 1000.0 2000.0 3000.0 4000.0 5000.0 Air Flow (CFM) 16.0 S'A'SI-Plenum Supply Fan at Standard Conditions Base Tag HRU-1 Date Nov-17-2021 Job Name Hunter Davisson-Dartmouth Cross... Time 2:07 PM Air Volume 2800 CFM Fan Speed 2047 RPM Total Static 2.56 inWg Max Speed 2550 RPM Brake Horsepower 1.74 HP Efficiency 66 55 Unit Sound Power 63hz 125hz 250hz 500hz 1000hz 2000hz 4000hz 8000hz Inlet Sound Power 74 72 80 75 77 71 66 60 Outlet Sound Power 74 75 83 80 83 77 74 68 Radiated Sound Power 85 85 81 78 7.6 ' 71 64 57 r DA/K!N Job Number: GQM31Z Page Prepared Date: 11/17/2021 Job Name: Hunter Davisson-Dartmouth 12 of 41 www.DaikinApplied.com • Fan Curve - Exhaust for HRU-1 Daikin Fan Selection 5.0 • ., 2059 RPM / 2000$PM - '- " - _ , _ • .., / . \ % -NeN44444\ \\.,,, ` \ .11444,11111114L 4N010\ d 3.4 1840 RPM O N \ co1 .10RPM \ IC 2.0 :- W RPM ` Abitia, -.4.44 .,.4111N111111111111141\ fA _ - 1000 RPM 1 .4 — --"%mr4404i4.141110 : ?�,� •800 RPM iy 40 0.0 "r- "—I I I I I II I I I t --1 0.0 1000.0 2000.0 3000.0 4000.0 5000.0 6000.0 7000.0 Air Flow (CFM) 18.0 S'WSI-Plenum Exhaust Fan at Standard Conditions 'Base iag HRU-1 Date Nov-17-2021 Job Name Hunter Davisson-Dartmouth Cross... Time 2:07 PM Air Volume 2335 CFM Fan Speed 1481 RPM Total Static 2.1 inWg Max Speed 2050 RPM Brake Horsepower 125 HP Efficiency 62 % r DAIKIN Job Number: GQM31Z Page Prepared Date: 11/17/2021 Job Name: Hunter Davisson- Dartmouth 13 of 41 www.DaikinApplied.com Technical Data Sheet for HRU-2 Job Information Technical Data Sheet Job Name Hunter Davisson -Dartmouth Crossing `J Date Robert 1 Submitted By Robert Grace e Software Version 09.40 Unit Tag HRU-2 Unit Overview Model Number Voltage Design Cooling EER@95/75 EAT&200 CFM/ton ISMRE Per AHRI V/Hz/Phase Capacity EER IEER 920-2016 Btu/hr DPS007A 208/60/3 87916 12.6 Not Available ASHRAE 90.1-2016 compliant Unit Model Number: DPS007A Model Type: Heat Pump Heat Type: Electric Energy Recovery: ERW-Med Cab-Econ:2835 cfm max, 100%OA:5145 cfm max Application: Variable Air Volume,Single Zone(Mixed Air or 100%OA) Controls: Microtech III Outside Air: 100%Outside Air Altitude: 0 ft Approval cETLus Physical Dimensions and Weight Length Height Width Weight 111.0 in 56.8 in 96.5 in 2486 lb Corner Weights L1 L2 L3 L4 464 lb 415 lb 759 lb 848 lb Construction Exterior Insulation and liners Air Opening Location Return Supply 1" Injected Foam, R-7, Painted Galvanized Steel Galvanized Steel Liner Bottom Bottom Electrical Unit FLA MCA MROPD SCCR 92.1 A 107.6 A 110 A 5 kAIC Note: Use only copper supply wires with ampacity based on 75°C conductor rating. Connections to terminals must be made with copper lugs and copper wire. Job Number: GQM31Z Page Prepared Date: 11/17/2021 Job Name: Hunter Davisson -Dartmouth 14 of 41 www.DaikinApplied.com • Technical Data Sheet for HRU-2 Return/Outside/Exhaust Air Outside Air Option Type Damper Pressure Drop Exhaust Air Type Powered, Modulating with Building None 0.08 inH:O Pressure Control Exhaust Fan Type Drive Type Wheel Diameter SWSI AF Direct Drive 18 in Motor (Qty)Horsepower Type Efficiency Full Load Current(Each) (1)4.0 HP ECM Premium 8.8 A Performance Air Flow External Static Pressure Fan Speed Brake Horsepower CFM inH2O RPM HP 2635 1.50 1503 1.35 Energy Recovery Design OA Volume Design Exhaust Volume Wheel Pressure Drop Motor HP Motor FLA 2585 CFM 2635 CFM 0.49 inF60 0.17 HP 0.7 A Summer Conditions Temperature Recovered Effectiveness Outside Air Return Air Wheel Leaving Mixed Air Capacity Total Sensible Dry Bulb Wet Bulb Dry Bulb Wet Bulb Dry Bulb Wet Bulb Dry Bulb Wet Bulb Btu/hr °F °F •F °F °F °F °F °F 95.0 70.0 75.0 62.0 82.1 65.4 82.1 65.4 42335 54.27 64.41 Winter Conditions Temperature Recovered Effectiveness Outside Air Return Air Wheel Leaving Mixed Air Capacity Total Sensible Dry Bulb Wet Bulb Dry Bulb Wet Bulb Dry Bulb Wet Bulb Dry Bulb Wet Bulb Btu/hr 'F °F °F °F °F °F °F °F 22.0 19.0 70.0 54.0 54.5 44.2 54.5 44.2 120927 65.78 67.65 Bypass Damper: No Energy Recovery Filters Quantity/Size Face Area Face Velocity Air Pressure Drop Efficiency Outdoor Exhaust Outdoor Exhaust Outdoor Exhaust Outdoor Exhaust 'IV f ft/min ft/min inHzO inH5O 2 in. MERV 8 (3)18 in.X 24 in. (3) 18 in.X 24 in. 9.0 9.0 287.2 292.8 0.10 0.10 Combined Efficiency Factor Application Specific CEF: 11.9 Filter Section Physical Type Quantity/Size Face Area Face Velocity Air Pressure Drop Combo 2"/4" rack with 2" MERV B 6/18 in x 24 in x 2 in 18.0ft' 143.6ft/min 0.04 Job Number: GQM31Z Page Prepared Date: 11/17/2021 Job Name: Hunter Davisson-Dartmouth 15 of 41 www.DaikinApplied.com Technical Data Sheet for HRU-2 DX Cooling Coil Physical Coil Type Refrigerant Type Fins per Inch Rows Face Area Face Velocity Air Pressure Drain Pan drop Material Cu Tube/Al R410A 15 3 14.0 ft2 184.4 ft/min 0.11 inH2O Stainless Fin Steel Cooling Performance Capacity Indoor Air Temperature Ambient air Total Sensible Moisture Entering Leaving Temperature Btu/hr Btu/hr Removal Dry Bulb Wet Bulb Dry Bulb Wet Bulb Dewpoint °F lb/h °F 'F 'F °F 'F 87916 78843 7.5 82.1 65.4 54.2 54.1 54.1 95.0 Condensate Connection Size: 3/4 in. Male NPT Heating Performance Total Capacity Refrigerant Indoor Air Temperature Dry Bulb Ambient Air Btu/hr Type Entering Leaving Temperature °F 'F °F 56498 R410A 54.5 74.5 23.0 Fan Section Fan Type Fan Wheel Diameter Fan Isolation SWSI AF 16 in None Performance Airflow Total Static Pressure Fan Speed Brake Horsepower Altitude 2585 CFM 2.4 inH2O 1941 rpm 1.50 HP 0 ft Motor Drive Type Horsepower Efficiency FLA Type ECM Motor 4.0 Premium 8.8A Direct Drive Electric Heat Section Physical Electrical Airflow Size Control FLA A 2585 CFM 18 kW SCR control 50.0 Performance Capacity Air Temperature Air Pressure Drop Btu/hr Entering Leaving inH2O °F °F 61434 54.5 76.4 0.11 Unit Discharge Conditions AirTemperature Motor Heat Moisture Removal Unit Leaving Dry Bulb Unit Leaving Wet Bulb Unit Leaving Dewpoint Btu/hr lb/h 'F 'F °F 4831 7.5 56.0 54.7 54.1 Minimum Airflows Fan Only Minimum Airflow Cooling Minimum Airflow Heating Minimum Airflow 853 CFM 1052 CFM 944 CFM Notes: Refer to fan curve for applicability of approximate airflows Job Number: GQM31Z Page Prepared Date: 11/17/2021 Job Name: Hunter Davisson-Dartmouth 16 of 41 www.DaikinApplied.com • Technical Data Sheet for HRU-2 Condensing Section Compressor Type Quantity Refrigerant Charge Total Power Capacity Control Compressor Isolation lb Inverter Scroll 2 26.0 5.79 kw Mod Control with Rubber in Shear Inverter Compressor Compressor Amps: Compressor 1 11.9 A Compressor 2 8.6 A Condenser Coil Type Fins per Inch Fin Material Copper Tube 16 Aluminum Condenser Fan Motors Number of Motors Full Load Current(Total) 2 4.0 A Internal Pressure Drop Calculation External Static Pressure: 1.50 inHzO Filter: 0.04 inHzO Outside Air: 0.08 inH:O Energy Recovery: 0.58 inH2O DX Coil: 0.11 inH2O Electric Heat: 0.11 inH2O Total Static Pressure: 2.42 inH:O Sound Sound Power(db) Frequency 63 Hz 125 Hz 250 Hz 500 Hz 1 kHz Z kHz 4 kHz 8 kHz Inlet 73 71 79 74 76 70 65 59 Discharge 73 74 82 79 82 76 73 67 Radiated 85 85 81 78 76 71 64 57 Options Unit Smoke Detectors: Return Air Smoke Detector Electrical Field Connection: Non-Fused Disconnect Switch Powered Receptacle: Unit powered 115V GFI outlet Power Options: Phase Failure Monitor Factory Installed Sensors Leaving Coil/Entering Fan Temperature Sensor Duct High Limit Switch Return Air Temperature Sensor Discharge Air Temperature sensor-Wired in unit,mounted in supply duct Outside Air Temperature Sensor Dirty Filter On/Off Switch Supply Fan Air Proving Via Modbus Building Static Pressure Sensor Supply Leaving Wheel Temperature Sensor Exhaust Leaving Wheel Temperature Sensor Job Number: GQM31Z Page Prepared Date: 11/17/2021 Job Name: Hunter Davisson-Dartmouth 17 of 41 www.DaikinApplied.com Technical Data Sheet for HRU-2 Warranty Parts: Standard One Year Compressor: Standard One Year Notes Job Number: GQM31Z Page Prepared Date: 11/17/2021 Job Name: Hunter Davisson-Dartmouth 18 of 41 www.DaikinApplied.com s2 ID ivs la c 3 3 jw • or isF.s a1 0 c mw S I 3 66.5 0 m- i--1—4". pM.A.INFDGE LET r BOTT A DWI f - i �l 4 , f 7 a a pm 36.5 i r =• _II I ❑ [� _ " if am. . � n5' - s .s v ,. .. rEry @R ',QV...,r 7" r0.0 v al111.t) w !132.7 n a. v as g 1 e Notes: v (1)Recommended location for optional field cut side power connection. x n r- Product Drawing Unit Tag:HRU-2 Sales Office:Oregon Air Reps(Portland) ,DA/K/N p 3 ,_., Product: Project Name:Hunter Davison-Dartmouth Sales Engineer:SalesEngineer . 13600 Industrial Park Blvd.Minneapolis.MN 55441 1 `.- Model:DPS007A Nov.17,2021 I Verifier Sheet l oft Scale:NTS I Tolerance:+/-0.25' I Dwg Units:In(mini www DaikinAoolled rem Software Version 0940 j O 3 N No change to this drawing may be made unless approved in writing by Daikin Applied.Purchaser must determine that the equipment is fit and sufficient for the job specifications. Drawings(2) for HRU-2 62.8 CONDENSER 96.5 33.9 POWER ENTRY 57.9 47.4 18.8 t 20.5 13.6_ f 5.3 25.0 — —12.9-- DRAIN 59.3 HEIGHT 6.6 102.9 106.3 111.0 132.7 PLAN VIEW - OPENINGS & OVERALL Product Drawing Unit Tag:HRU-2 V DAIKIN Product: Project Name:Hunter Davisson- 13600 Industrial Park Blvd.Minneapolis,MN 55441 Model:DPS007A Sales Office:Oregon Air Reps Portland) www.DaikinA plied.com Software Version:09.40 Sales Engineer:SalesEngineer Nov.17,2021 I Ver/Rev: f Sheet 1 of 1 Scale:NTS Tolerance:+/-0.25" I Dwg Units:in Imm] No change to this drawing may be made unless approved in writing by Daikin Applied. Purchaser must determine that the equipment is fit and sufficient for the job specifications. Job Number: GQM31Z Page Prepared Date: 11/17/2021 Job Name: Hunter Davisson-Dartmouth 20 of 41 www.DaikinApplied.com _ v m tic zz f N c 9 Q 00 N GO WAM . O co '3Corner Weight L3-759 lb 7=0 A N, Corner Weight L4-848 lb ON _ C ca N C C = GOMenser 0 w 3 cc sox - 36.0-- J S i a d aW Y Q Eneryy Recovery CNI i3$$ $ oWN V 37.5 u vI3, m 7 im J r Corner Weight L2-415 lb Corner Weight L1-46411b gc.0 a a a m g PLAN VIEW-CG,CORNER WEIGHTS,SERVICE CLEARANCE i Notes: (1)Center of Gravity Height=25.7 vo (2)Total Weight=2486 lb Pr n 1-- Product Drawing Unit Tag:HRU-2 Sales Office:Oregon air Reps(Portland) 'Dq/K/A! a i Product: Project Name:Hunter Davison-Dartmouth Sales Engineer:SalesEngineer ,.+ 13600 Industrial Pad Blvd.Minneapolis,MN 55941 2- ..... Model:OPS007A Nov.17,2021 I Ver/Pev: I Sheet: le l off Scale:NTS I Torance:-n 0.25- I Dwg Units:in tmm] www DaikinAoolied corn Software Version.0940 3 N No change to this drawing may be made unless approved in writing by Daikin Applied.Purchaser must determine that the equipment is fit and sufficient far he job specifications. J P V 2 211. cn p 0. Q 1/1 cOc S p • m P. o f 3 co O v y • , N r w 1 dill -- 42 01 — 14.25 - 24.66 .11.50'+ 4217 — 50310 12 ID 12 w 1• C. O m m 7 E. n" J j r1--' Product Drawing Unit Tag:HRU-2 Sales Office:Oregon Air Repslportland) ,DA/K/N tiV Product: Project Name:Hunter Davi55on- Sales Engineer: 1 13600 Industrial Park Blvd.Minneapolis,MN 55441 N Model:DPS007A Nov.17,2021 I Ver/Rev: I Sheet:1 of I Scale:NTS I Tolerance:y-0.25' I Owg Units:in lmml www.oaikinApplied.com Software Version:09.40 J O 3 r No change to this drawing may be made unless approved in writing by Daikin Applied.Purchaser must determine that the equipment Is fit and sufficient for the job specifications. STANp Rn CONSTRUCTION oETal�. ®awEPµpWt2nlCEOptR.xI.li+141I2 REVISIONS DUCT FLEX CONNECTIONS PROVIDED BY OTHERS REV [COY DESCRIPTION DATE APPROVED 1 X 4 WOOD NAILER I MEAL DRAWING II/I/I/I SRP SPRING ACCESS DOORS ARE GASKETED AND 2 UPDATED IBC.CSC ANx NW21 SOP SCREWED ON FROM DRAWING GASKET MATERIAL PROVIDED FOR THE TOP OVERALL 14GA BOXED TOP FRAME PERIMETER(INCLUDING BRACES) HEIGHT 291/4 281M 901/4 381/4 SPRING PACKS MAY REQUIRE FIELD ADJUSTMENT BASE CURB HEIGHT 11 14 18 24 �\ RETURN (BY OTHERS) BASE MATERIAL GA 14 14 14 14 FULLY WELDED GALVANIZED(Od0)CONSTRUCTION CURB WEIGHT 456 478 610 558 ��O. +I WEATHER SEAL BETWEEN UPPER&LOWER 11 `. 1BGA DUCT BRACES S CURB OP ROOF FOR LB STEEL, 1 • �G \` ORANCHORING OD, CURBTOL ROOF FOR CONCRETE OR WOOD,SEE D.SEISMIC-AT AACH EN ANCHOR' SUPPLY FORM NO.SEISMIC-ATTACHMENTS / '\` ��` '.\ J 1 IIIIII CURB BASE 1` '. Q. 38 TIT `a. \I , //, 7 14GA D SPRING \\��/ W SUPPORTS UNDER EA 0: SPRING(INSULATED) 11I' [ T 5"REF HEM BASE FLANGE 234' UNIT BASE RAIL 351/2'—�� gA 59 3/4" 901/4" 1/4'TEK SCREW THRU .-- UNIT BASE RAIL AND CURB '■ PER STAMPED REPORT 58 1/4" 52318' . • 1051/2' 2 I 7 I 102'I.D. I i1" 2UT I BASE CURB I.D.48 vs" . I _____BASECURB+121/4 1 I I It i• CURB 1 (%'MAX WITH PITCH) _ I / D SCALE :4 BASE SC 1 ALE) HEIGHT 11.01.01111.11.11* .w.cexruEm mwaP.r54a, .E..w.S d?E CURB DESIGNED TO MEET SEISMIC&WIND LOAD REQUIREMENTS FOR n<5,mvvm.,P 7Pm E �.KPTnPmrIP.PC 478.16 z.v* C7-OOXX-7723 20181BC/ASCET-16,AND 2020 FBC FLORIDA BUILDING CODE.Z019 CSC SEISMIC ISOLATION CURB N:wlm m ° p1�pY1°OM NC WIND DESIGN:MAX BUILDING HEIGHT SOFT,KO FACTOR=1.00 MAX ^ '. TUCESY ASIDE 2021 Y.{239 AM 20181BCASLE 7-18 MA%186 MPH ULTIMATE DESIGN WIND 6PE®,RISK 3D ASSEMBLY "M� 7/TIP IMIO MPS ST NR "r` CATEGORY II,III.OR N BUILDING.EXPOSURE C CRAW.LAV011r 6.1114.21•21FICA.1011 IF CDI ELK RIVER.YN M3M �i-0NOt-m3 n SEISMIC:SR=2.00 MAX.IMPORTANCE FACTOR Ip=t.S IV R.IGw/w wvEw uorrmmon I4►8 (N)NRI-Ill W.2 222I em I r I S:ICURBS CURB ADAPTERSICX-X.V000OOLCONFORMINGICI-003I-XXXX_I60_CURBS RNLS1C74110XX-77E00C7-00X5-77231 Technical Data Sheet for HRU-3 Job Information Technical Data Sheet 14, Job Name Hunter Davisson -Dartmouth Crossing Date 11/17/2021 Submitted By Robert Grace e Software Version 09.40 Unit Tag HRU-3 Unit Overview Model Number Voltage Design Cooling EER@95/75 EAT&200 CFM/ton ISMRE Per AHRI V/Hz/Phase Capacity EER IEER 920-2016 Btu/hr DPS007A 208/60/3 92503 12.6 Not Available ASHRAE 90.1-2016 compliant Unit Model Number: DPS007A Model Type: Heat Pump Heat Type: Electric Energy Recovery: ERW-Med Cab-Econ:2835 cfm max, 100%OA:5145 cfm max Application: Variable Air Volume,Single Zone (Mixed Air or 100%OA) controls: Microtech III Outside Air: 100%Outside Air Altitude: 0 ft Approval cETLus Physical Dimensions and Weight Length Height Width Weight 111.0 in 56.8 in 96.5 in 2486 lb Corner Weights Ll L2 L3 IA 464 lb 415 lb 759 lb 848 lb Construction Exterior Insulation and Liners Air Opening Location Return Supply Painted Galvanized Steel 1" Injected Foam, R-7, Galvanized Steel Liner Bottom Bottom Electrical Unit FLA MCA MROPD SCCR 92.1 A 107.6 A 110 A 5 kAIC Use only copper supply wires with ampacity based on 75°C conductor rating. Connections to Note: terminals must be made with copper lugs and copper wire. Job Number: GQM31Z Page Prepared Date: 11/17/2021 Job Name: Hunter Davisson -Dartmouth 25 of 41 www.DaikinApplied.com Technical Data Sheet for HRU-3 DX Cooling Coil Physical Coil Type Refrigerant Type Fins per Inch Rows Face Area Face Velocity Air Pressure Drain Pan drop Material Cu Tube/Al Stainless Fin R410A 15 3 14.0 ft2 217.5 ft/min 0.12 inH:O Steel Cooling Performance Capacity Indoor Air Temperature Ambient air Total Sensible Moisture Entering Leaving Temperature Btu/hr 8tu/hr Removal Dry Bulb Wet Bulb Dry Bulb Wet Bulb Dewpoint °F lb/h °F °F °F °F °F 92503 91960 0.0 84.4 66.3 56.9 56.5 56.2 95.0 Condensate Connection Size: 3/4 in. Male NPT Heating Performance Total Capacity Refrigerant Indoor Air Temperature Dry Bulb Ambient Air Btu/hr Type Entering Leaving Temperature °F °F °F 57792 R410A 48.4 65.7 23.0 Fan Section Fan Type Fan Wheel Diameter Fan Isolation SW51 AF 16 in None Performance Airflow Total Static Pressure Fan Speed Brake Horsepower Attitude 3050 CFM 2.7 inH:O 2129 rpm 1.95 HP 0 ft Motor Drive Type Horsepower Efficiency FLA Type ECM Motor 4.0 Premium 8.8 A Direct Drive Electric Heat Section Physical Electrical Airflow Size Control FLA A 3050 CFM 18 kw SCR control 50.0 Performance Capacity Air Temperature Air Pressure Drop Btu/hr Entering Leaving inHzO .F °F 61434 48.4 66.9 0.14 Unit Discharge Conditions AirTemperature Motor Heat Moisture Removal Unit Leaving Dry Bulb Unit Leaving Wet Bulb Unit Leaving Dewpoint Btu/hr lb/h °F °F 'F 5972 0.0 58.7 57.1 56.2 Minimum Airflows Fan Only Minimum Airflow Cooling Minimum Airflow Heating Minimum Airflow 1006 CFM 1052 CFM 944 CFM Notes: Refer to fan curve for applicability of approximate airflows Job Number: GQM31Z Page Prepared Date: 11/17/2021 Job Name: Hunter Davisson -Dartmouth 27 of 41 www.DaikinApplied.com Technical Data Sheet for HRU-3 Condensing Section Compressor Type Quantity Refrigerant Charge Total Power Capacity Control Compressor Isolation lb Inverter Scroll 2 26.0 5.80 kw Mod Control with Rubber in Shear Inverter Compressor Compressor Amps: Compressor 1 11.9 A Compressor 2 8.6 A Condenser Coil Type Fins per Inch Fin Material Copper Tube 16 Aluminum Condenser Fan Motors Number of Motors Full Load Current(Total) 2 4.0 A Internal Pressure Drop Calculation External Static Pressure: 1.50 inH2O Filter: 0.06 inH2O Outside Air: 0.11 inH2O Energy Recovery: 0.72 inH2O DX Coil: 0.12 inH2O Electric Heat: 0.14 inH2O Total Static Pressure: 2.65 inH2O Sound Sound Power((lb) Frequency 63 Hz 125 Hz 250 Hz 500 Hz 1 kHz 2 kHz 4 kHz 8 kHz Inlet 75 73 81 76 78 72 67 61 Discharge 75 76 84 81 84 78 75 69 Radiated 85 85 81 78 76 71 64 57 Options Unit Smoke Detectors: Return Air Smoke Detector Electrical Field Connection: Non-Fused Disconnect Switch Powered Receptacle: Unit powered 115V GA outlet Power Options: Phase Failure Monitor Factory Installed Sensors Leaving Coil/Entering Fan Temperature Sensor Duct High Limit Switch Return Air Temperature Sensor Discharge Air Temperature sensor-Wired in unit,mounted in supply duct Outside Air Temperature Sensor Dirty Filter On/Off Switch Supply Fan Air Proving Via Modbus Building Static Pressure Sensor Supply Leaving Wheel Temperature Sensor Exhaust Leaving Wheel Temperature Sensor Job Number: GQM31Z Page Prepared Date: 11/17/2021 Job Name: Hunter Davisson-Dartmouth 28 of 41 www.DaikinApplied.com Technical Data Sheet for HRU-3 Warranty Parts: Standard One Year Compressor: Standard One Year Notes Job Number: GQM31Z Page Prepared Date: 11/17/2021 Job Name: Hunter Davisson- Dartmouth 29 of 41 www.DaikinApplied.com • 5 0` v J P W Z 2 r e 3 9 gr On M tow 33 pV C es C W rn O op. firirlii"I'41111"1111111.17e' 56.8 / : , O A.INLET ROT-rah'EDGE WV Y a I 7 -0 t M w 1 p m 36.5 11 r7 " .�f ( lI L 9 .5 �Po s _ iv WBR NEIpHT tO 0 3 111.p a 132.7 a 0 m m' 1 E Notes: v (1)Recommended location for optional field cut side power connection. R 3 Dpa Product Drawing Unit Tag:HRU-3 Sales Office:Oregon Ale Reps 1pontla.rdf 'DAIK/N r 9. . Product: Project Name:Hunter Davison-Dartmouth Sales Engineer:SalesEngineer 13600Industnal Park Blvd.Minneapolis,MN 55441 a- Model:DPS007A Nov.12,2021 I Ver/Rev: I Sheet 1 of 1 Scale.NTS I Tolerance:c/-0.25' I D Units:In Imml von*DaikinAoolled own Software Version'09 40 O3 3 Ili No change to this drawing may be made unless approved in writing by Daikin Applied.Purchaser must determine that the equipment is fit and sufficient for the job specifications. Drawings(2)for HRU-3 62.8 29.9 CONDENSER • 96.5 33.9 POWER ENTRY 57.9 47.4 18.8 t 20.5 13.6 5..3 25.0 - 12.9--- DRAIN 59.3 HEIGHT 6.6 102.9— 106.3 - 111.0 132.7 — PLAN VIEW - OPENINGS & OVERALL Product Drawing Unit Tag:HRU-3 VDAIK1PJ Product: Project Name:Hunter Davisson- 13600 Industrial Park Blvd.Minneapolis,MN 55441 Model:DPS007A Sales Office:Oregon Air Reps(Portland) www.DaikinAyplied.com Software Version:09.40 Sales Engineer:SalesEngineer Nov.17,2021 Ver/Rev: I Sheet 1 of 1 Scale:NTS If Tolerance:14-0.25" Dwg Units:in Imm] No change to this drawing may be made unless approved in writing by Daikin Applied. Purchaser must determine that the equipment is fit and sufficient for the job specifications. Job Number: GQM31Z Page Prepared Date: 11/17/2021 Job Name: Hunter Davisson-Dartmouth 31 of 41 www.DaikinApplied.com 1 T c Si £ sa z D c 3 3 tm e g -- 60.0 W.. xct 0 cp mw Corner Weight L4-848 lb Corner Weight L3-759lb a C CNN to 0.1 5. � condenser O a. P. 3 c 50.0 -313.0—•• ..... 1 r EneD s%emery a owi u vs It O 5W� a 37.5 l v v Pa'j m // �-Corner Weight L2-4151b Corner Weight Lt-464 Ilb J Bo.o v a 9 N a a. o 52.4 m m PLAN VIEW-CG,CORNER WEIGHTS,SERVICE CLEARANCE Notes: s (1)Center of Gravity Height=25.7 v (2)Total Weight=2486 lb Y F+ Product Drawing Unit Tag:HRU-3 Sales Office:Oregon Air Reps{Portland) pirOAIKIN z Product: Project Name:Hunter Davisson-Dartmouth Sales Engineer:SalesEngineer 3 JUnits:in lmm] 13600 Industrial Park Blvd.Minneapolis,MN 55441 Model:DPS007A Nov.17,2021 I Ver/Rev: I sheet:t of Scale:NTS I Tolerance:t/-0.25" I Dwg wws,DaikinAaoliedcom Software Versian:0940 3 N No change to this drawing may be made unless approved in writing by Daikin Applied.Purchaser must determine that the equipment is fit and sufficient for the job specifications. 5 o V s 1- 2 2 U' v c ci v t O O Sc1 3p ao m3 /f so < NIMI . CC v INN. ,.. p o M Q III y r V Ii W I.---_.42.01 14.25 -- 24.68 4-11.50. 42.17.-- 44. 50.00 v N a. 1a m O. v to g 1 e 1 ik 5 r .; Product Drawing Unit Tag:HRU-3 Sales office:Oregon Air Reps(Portland) D. V Product: Project Name:Hunter Davisson- Sales Engineer: 13600 �DA/K/N 1 � Model:DPSOO7A Nov.17,2021 J Ver/Rev: I Sheet:1 of 1 Scale:NTS I Tolerance:•- I ww.D IndustrialinApolid.coark ghd.Minneapolis,MN 55441 G /0.25" Owg Units:in[mm[ www0aikinApplied.com Software Venlore 09.00 3 N No change to this drawingmay be made unless g approved in writing by Daikln Applied.Purchaser must determine that the equipment is fit and suffirieM for the job specifications. • STANDARD CONSTRUCTION DPTAII S DIM.3..1FO..0.aa1.MI IMC..5411.16.1412 REVISIONS DUCT FLEX CONNECTIONS PROVIDED BY OTHERS REV ECO4 DESCRIPTION DATE APPROVED IX4 WOOD NAILER I INITIAL DRAWING Il/I/10 SRP SPRING ACCESS DOORS ARE GASKETED AND 2 UPDATED IBC.cBc a r0c 4/15121 SEP SCREWED ON FROM DRAWING GASKET MATERIAL PROVIDED FOR THE TOP 14GA BOXED TOP FRAME PERIMETER(INCLUDING BRACES) OVERALL 231/4 281M an 1!4 %iN SPRING PACKS MAY( REQUIRE FIELD ADJUSTMENT BASE CURB MAISRELGA 11 14 14 14 /�\ RETURN (BR OTHERS) BASE CARERIEL GA 11 14 14 14 ;. FULLY WELDED GALVANIZED(G-90)CONSTRUCTION CURB WEIGHT 464 47B 510 555 �6, WEATHER SEAL BETWEEN UPPER 6 LOWER I �`�/\ 18GA DUCT BRACES SEC11DNS PRROOF F(BULB SEAL) i 1�\ ANCHORING CURB TO ROOF FOR 'ROOF CONCRETE ' '� 1� I. OR WOOD"SEE DETAIL DRAWING-ATTAC ANCHOR" SUPPLY FORM NO.SEISMIC-ATTACHMENTS `'1 \ ``` B. CURS BASE ` ' / G.CL 387/8" `ING �I , Si 5. rM in SUPPORTS UNDER EA C1SPRING(INSULATED) Ou 5'REF HEM BASE FLANGE / - 22" \ 2 3/4" it„, ---���iii UNIT BASE RAIL -.—3512" 59 3M' -. 801/4" 114"TEK SCREW THRU __ UNIPER STAMPED REPORT �: — PER SEAMPEA REPORT 581/4" � 10512" 523/8' 2- 102'I,D. 1 _ 1. 2 12'i-'—.i I 487/8'BASE CURB I.D.—al I J 1iiiIIIIIIIIIMII BASE CURB E 121/4 I I 7" CURS 1 I ` u u (38'MAX WITH PITCH) I I I I gGLE 1:4 BASE HEIGHT CURB I r DETAIL: HEIGHT cum.owl NW wa nn< CURB DESIGNED TO MEET SEISMIC A WIND LOAD REQUIREMENTS FOR 47816 4..../ 201E IBC/ASCE 7-16.MD 2020 FBC FLORIDA BUILDING CODE.2019 CRC cz s.uws.nanw I''' C7-OOXX-7723 WIND DESIGN:MAX BUILDING HEIGHT GIFT.K>3 FACTOR=1.00 MAX SEISMIC ISOLATION CURB ions "p,.. Tutlw Hp9ID M17y72B NA 3D ASSEMBLY a.: 201E IBC/ASCE 7-15:MAX 186 MPH ULTIMATE DESIGN WIND SPEED.RISKgmr. mZIP ^^"•,,. L'GF� ���117 l URS I c/ x-nn CATEGORY II,III,OR IV BUILDING,EXPOSURE G (EtL1K] III 2 SEISMIC:Ss=200 MAX,IMPORTANCE FACTOR Ip•15 [affial.r101.all hil/Si BC MCP mwnxcav ORDER � S� I4� (76 11p1:1651 MS" �= I wO 122 1.a..1 a 9 SICURB3 CURB ADAPTERSICS-XXXX3000(CONFORMINGIC7-JDW(70DO ISO_CURBS_RAILSIC7-XXXX-7XX)OC7AO)0X-T7231 Fan Curve - Supply for HRU-3 Daikin Fan Selection 2550 RPM 1ti `N 5.0 — .. \, _ 2400 RhM • fr. � 0 RP \ '4 \ /� ' .,.' _ _ ` f • t W - '1 1 RPM\ _ -in 10 RP�ti � CD v - 1600 RPM �, 2.0 . ` • All ftlIN"%e 'a1200 RPM ''1 .0 —r000 RPM• . • ' \ _- O •, _894 RPMANEW . ? - 0.0 • --- i I I I I I I I I I I I I I I \ I '', , 0.0 1000.0 2000.0 3000.0 4000.0 5000.0 Air Flow (CFM) 16.0 SVWSI-Plenum Supply Fan at Standard Conditions Base Tag HRU-3 Date Nov-17-2021 Job Name Hunter Davisson-Dartmouth Cross.-. Time 2:07 PM Air Volume 3050 CFM Fan Speed 2129 RPM Total Static 2.65 inWg Max Speed 2550 RPM Brake Horsepower 1.95 HP Efficiency 65 % Una Sound Power 63hz 125hz 250hz 500hz 1000hz 2000hz 4000hz 8000hz Inlet Sound Power 75 73 81 76 78 72 67 61 Outlet Sound Power 75 76 84 81 84 78 75 69 Radiated Sound Power 85 85 81 78 76 71 64 5 r jr DAIKIPJ Job Number: GQM31Z Page Prepared Date: 11/17/2021 Job Name: Hunter Davisson - Dartmouth 34 of 41 www.DaikinApplied.com Fan Curve - Exhaust for HRU-3 , Daikin Fan Selection 5.0 , . 2050 RPM • `,., • -ice!)RPM - ti ..-._.-_ ,. A 4.0 \ 73 c \\1 • L3.a —1600RPMNA* ....,,y .11111raftir . N itL _ 1 :iRPM 2 0 —. . .lira._ ''",.NosttiN \ c 1 ',, RPM _ - um RPM ,c, - -800 RPM 's 'S,p allr411111kIN O) 144 Ili 's'_ RS_ \ 0.0 1000.0 2000.0 3000.0 4000.0 5000.0 6000.0 7000.0 Air Flow (CFM) 18.0 S'ArSI-Plenum Exhaust Fan at Standard Conditions Base Tag HRU-3 Date Nov-17-2021 Job Name Hunter Davisson-Dartmouth Cross... Time 2:07 PM Air Volume 2280 CFM Fan Speed 1487 RPM Total Static 2.2 inWg Max Speed 2050 RPM Brake Horsepower 1.25 HP Efficiency 62 °h /DAMMMN Job Number: GQM31Z Page Prepared Date: 11/17/2021 Job Name: Hunter Davisson- Dartmouth 35 of 41 www.DaikinApplied.com Rebel Rooftop ECM Fan PDAIKIN ebmpapst II..My nrn l<1o.r1 Rebel® Electronically Commutated Motor (ECM) Fan Description .r•` Rebel's Supply and Exhaust tans utilize a direct drive H Electronically Commutated Motor(ECM)fans, • Features w J The ECM fans have low vibration,low noise,and have the same •1 L if not higher efficiency than motors with Variable Frequency Drives(Ms].Direct drive design means no belt maintenance Dimensions Fan Size fl) (W) (H) Motor HP 12" 11.12 16.54 16.54 1-3 14" 12.86 16,54 16.54 2.3 16" 14.27 18,12 18.12 4.0 18' 15.5 25.2 25.2 4.0 22" 18.03 25.2 25.2 4.0 or 8.0 For further information,visit www.ebmpapst.us I.rvn/wow eauvu.111r.NO lu.11.r,.no.r.nndI,.v Jln ,sr y.Wut �.f.m. nwrR an..a.".wew a.ar.p• nw.....wr:lic.na-.w".rum C50-G0153-CVIjrp1-:3; 0:17020 n,1.l:n Applies I(a001 4 17-1 347 I wow a d a mP4an•d sew. 1 of 1 ..�_.,_�..,.w,._.. XIIU•1.101.1•2.Flat.1.3 Job Number: GQM31Z Page Prepared Date: 11/17/2021 Job Name: Hunter Davisson-Dartmouth 36 of 41 www.DaikinAppiied.com Rebel Rooftop Energy Wheel Filtration rDA)KSN Energy Wheel Filtration Description NI Rebel'and Maverick'II rooftop units with energy recovery wheels are factory provided with 2"MERV 8 filters on entering exhaust to the wheel and entering outside air to the wheel. An example of this is shown in the image below. Outside Air Filter i I. I Energy Recovery Wheel If IP: 1 Exhaust Air Filter t it 01 r. 2 m,.n&pow,:aa.o tla,rl m mlr...nn,J....op.is Jr,.,..a.r rynjrnl e50-0D179-00 UN n-181 a,Jab.ry naladrt WI.al.miff tl lu la morn. agm:mur, :rvalu bey IN morn.uwm.._anbxlu•.o•wr.r.•••.,.r,...., (/7070 C.:.n APO ed I Cano1437-1147 I wow DaAniMt,nd aam OOHS.ammo CFM Hear Wiwsi.Horlmntal,OOHS•6000 CRAMS Ambient.DOTS-aooe CFM IDS Ambient,HRU•t,HRU.2,MRU•3 Job Number: GQM31Z Page Prepared Date: 11/17/2021 Job Name: Hunter Davisson- Dartmouth 37 of 41 www.DaikinApplied.com Rebel Rooftop Mist Eliminator ',DARK IN Outside Air Mist Eliminator Description • This is the first item in the outdoor airstream in the Rebel' , and Maverick' II units.The main functions of this component rya. are to prevent moisture infiltration from the outdoor N, airstream as well as prevent entrance into the unit by foreign objects and animals. Media Construction The filter media element consists of two layers of corrugated aluminum screen mesh and an expanded aluminum retainer/faceguard.The filter media is completely enclosed in I ,. a durable,one-piece aluminum U-channel frame,closed at one corner with pop rivets, D,W.414s.N a-n,n„nl.runt,... mtat,vr neWa,Ram.v,,n.a no in*tent w.weo a u..,hsma a.m a-.. CSI] 87- . I,.�f-187 minnAHitt fondant mama*h,,.,:-n o-..n•.t<tro,enr,n I.,... ''107D Wokir Amp.nn i I81A)1437-1347 1 o, OCAS•l000 CFM Heat Wheel•Ralmetal,DOAS•0000 CFM 100 Ambler*.OCAS•1000 CFM LDS Ambient,HRU•1,11RU 2,Haifa Job Number: GQM31Z Page Prepared Date: 11/17/2021 Job Name: Hunter Davisson -Dartmouth 38 of 41 www.DaikinApplied.com Rebel Rooftop MTIII DDC Controller VDAllKIN MicroTech® III DDC Controller Description MicroTech III DDC control systems provide constant volume,vanade -„_,Y ��Y air volume,1009E outside air,and/or dehumidification control TM �`-"'"�' �•i flexibility.In addition to providing stably,efficient temperature.and """�-• static pressure control,the controller is capable of pnovding „s . y - r... • i comprehensive diagnostics,alarm monitoring,and alarm speuf c component shutdown if cntical equipment conditions occur.The and controllers are factory mounted artd configured for stand-alone ..i. operation or integration w th a building automat on system(BAS) through an optional communication module wth our Open Choices' feature Benefits The Mir roTech Ill provides easy,low-cost integration into most Features budding automation systems*theta cost I gateway panels. Each system is equipped with a complete MicroTech III unit control • Flexibility to select ether BACnet`or LONWORKS• system that is pre-engineered,preprogrammed,and factory tested -communication Units arc tonMarke 3.4 certified with the prior to shipment.Each MicroTech di unit control system is appropriate rommurl Cations module for LONWORxs networks. composed of several components that are individually replaceable for • Comprehensive unit control and status information is available rase of service.These components include: at the BAS regardless of communication protocol. • Long-term choices fur equipment additions at replacements, • Unit controller wick'user interface display and navigation wheel and for service support. • Optional expansion modules • Flexible alarm notification and prioritization with Intrinsic A'arm • Communication module(optional) Management(BACnetf • Pressure transducers(optlonaf) • Simplified BAS Integration with the ability to set network • Unit-mounted temperature scissors parameters at the unit controller,reducing installation time and • Zone temperature sensor packages(optional) lists • l$umidty sensor(optimal) • Easy monitormg and troubleshooting of communication status • SO card interface for application and operating system upgrade from the unit controller to the BAS. Expansion Modules Control Board (MCB) These hoards are used to expand the input and output capahi ity rN The main control board MCB(eon tains a microprocessor that is the unit cuntiuOrr.Cash board co nnunir.te%via serial data preprogrammed with the software necessary to control the unit This communications.These microprocessor-based boards provide ensures that schedules,setpoelts,and parameters are not lost,even Independent opera:on and alarm response even if communication is during a long-term power outage."he microprocessor board lost with the cnit controller. processes system input data and then determines and[whets output responses.An RS-232 communication port is provided as standard to alow for direct or modem access with a PC-based service tool. 0*,,awed can+sn n...ln a our.r,•sW.»wdr wua••e.,nv.r.,, C44O.02$-OC Lar•113 n.r,.rxw,.naLr t,s,rsl.na.a tit.ih J..O,.,^Vey v gw.+rar.u-.....{.,..... nuvveiwrr:.moms.,ar,. dyltv,t•.n•,.-LA'. ..•,.,,,. BA]n)n baikln Aotr,ed" Wn7147J.13471 view Da,llrAyxlwr.n.n cr 0OA5•$OOD UM teat Wheel•Horizontal,OOAS.EOOO CFM 100 Ambient,OOAs.MOO CFM 105 Ambient,RRU•1,RRU.2,NRU•3 Job Number: GQM31Z Page Prepared Date: 11/17/2021 Job Name: Hunter Davisson-Dartmouth 39 of 41 www.DaikinApplied.com Rebel Rooftop MTIII DDC Controller POA1K1Al Dimensions 1 1:11I ti 11:J°;.]P ... ..... .... ,M Q ' l � - , 1 �r • - y Specifications Operating voltage AC 24 V 120%;DC 24 V t10% Frequency 45—65 Hz Power consumption Approximately 15 VA(without extension modules) Max.AC current without 1.8 A AC 24 V extension modules Max.DC current without LOA@ DC 24V extension modules Max.current for extension 2.2 A e AC 24 V modules 3.0 A e DC 24 V Max.external supply line 10 A slow wire fuse or circuit fusing breaker Environmental Conditions Operation IE5 60721-3-3 class 3K5 Temperature -40 to 70°C Restriction LCD •20 to 60°C Restriction process bus -25 to 70°C Humidity <90%r.h.(non-condensing) Atmospheric pressure Min.700 hPa,corresponding to max.3,000 m above sea level Transport IEC 60721-3-2 lass IK3/2K4 Temperature •40 to 70°C Hum dity <95%r.h.(non-condensing) Mechanical conditions IEC 60721•3.2 class 2M2 2or2 Job Number: GQM31Z Page Prepared Date: 11/17/2021 Job Name: Hunter Davisson-Dartmouth 40 of 41 www.DaikinApplied.com } -memo., WEST COAST AIR PRODUCTS, INC. SUBMITTAL ler SUBMITTAL DATA RECEIVED For JUN 2 0 2023 Fire/Smoke Dampers CITY OF TIGARD BUILDING DIVrIoN Project: Dartmouth Crossing Date: 6/9/2023 Revision No.: Architect: BORA Architects Submitted for Approval Engineer: Hunter-Davisson Submitted by Sharon Watt Contractor: Hunter-Davisson WCAP Job: 23048 1. The product description for specification conformance is shown below. For dimensions and quantities,see attached data. 2. It is the contractor's responsibility to verify all sizes prior to ordering equipment.Sizes submitted are based on contract documents and must be verified against field conditions. 3. Unless otherwise noted,this data is submitted for approval by the authorized party. Orders released for production prior to receipt of such approval are the responsibility of the customer for conformance to specification and dimensional requirements. Changes made to orders placed without approval maybe subject to additional costs. Tag Qty Description Nominal Size Reference FSD-1 25 CESCO model CG2V250 See attached SD-CG2-21.04 With 18"sleeve, external 120V actuator and one set of 51-TLRA-18.09 angles. SI-ACTLOC-21.03 I I-FS-19.03 FSD-2 12 CESCO model CG2VF250 See attached SD-CA2GF-22.05 With 17"flanged sleeve, internal 120V actuator. II-FAGM-20.04 Actuators Siemens GJD-221.1U Siemens Data Sh. Total 37 Tel: (503)786-1412 Oregon WBE#1478 Fax: (503)786-1413 8800 SE Sunnyside Road,Suite 253-S Clackamas,OR 97015 WEST COAST AIR PRODUCTS, INC. tel: (503)786-1412 fax: (503)786-1413 BILL OF MATERIALS PRODUCT: CESCO Fire Dampers and Fire/Smoke Dampers PROJECT: Dartmouth Crossing MODEL ORIENTATION NOMINAL SIZE SLEEVE ACTUATOR LOCATION TAG QTY ( (BUILDING) NOTE NUMBER SEE NOTE 2) W H W H L MODEL LOCATION POSITION FSD-1 2 CG2V250 Vertical 6 6 8 6 18 GJD-221.1U EXT LEFT M101 1,2,4 FSD-1 1 CG2V250 Vertical 14 8 14 8 18 GJD-221.1U EXT LEFT M101 1,2 F5D-1 1 CG2V250 Vertical 16 8 16 8 18 GJD-221.1U EXT LEFT M101 1,2 FSD-1 3 CG2V250 Vertical 10 10 10 10 18 GJD-221.1U EXT LEFT M101 1,2 FSD-1 1 CG2V250 Vertical 8 8 8 8 18 GJD-221.1U EXT LEFT M101 1,2 FSD-1 1 CG2V250 Vertical 12 10 12 10 18 GJD-221.1U EXT LEFT M101 1,2 FSD-1 2 CG2V250 Vertical 10 8 10 8 18 GJD-221.1U EXT LEFT M101 1,2 FSD-1 1 CG2V250 Vertical 20 10 20 10 18 GJD-221.1U EXT LEFT M101 1,2 FSD-1 1 CG2V250 Vertical 10 10 10 10 18 GGD-221.1U EXT LEFT M102 1,2 FSD-1 2 CG2V250 Vertical 16 10 16 10 18 GJD-221.1U EXT LEFT M102 1,2 FSD-1 1 CG2V250 Vertical 10 6 10 6 18 G10-221.1U EXT LEFT M102 1,2 FSD-1 1 CG2V250 Vertical 10 8 10 8 18 GJD-221.1U EXT LEFT M102 1,2 FSD-1 1 CG2V250 Vertical 16 10 16 10 18 GJD-221.1U EXT LEFT M103 1,2 • F5D-1 1 CG2V250 Vertical 22 12 22 12 18 G10-221.1U EXT LEFT M103 1,2 • FSD-1 1 CG2V250 Vertical 14 10 14 10 18 GJD-221.1U EXT LEFT M103 1,2 FSD-1 2 CG2V250 Vertical 10 8 10 8 18 GJD-221.1U EXT LEFT M104 1,2 FSD-1 1 CG2V250 Vertical 16 8 16 8 18 GJD-221.1U EXT LEFT M104 1,2 FSD-1 1 CG2V250 Vertical 20 8 20 8 18 GJD-221.1U EXT LEFT M104 1,2 FSD-1 1 CG2V250 Vertical 14 10 14 10 18 GJD-221.1U EXT LEFT M104 1,2 FSD-2 1 CG2VF250 Front-access 10 10 10 10 17 GJD-221.1U INT RIGHT M101 1,3 FSD-2 3 CG2VF250 Front-access 12 8 12 8 17 GJD-221.1U INT RIGHT M102 1,3 FSD-2 1 CG2VF250 Front-access 16 14 16 14 17 GJD-221.1U INT RIGHT M102 1,3 FSD-2 3 CG2VF250 Front-access 10 14 10 14 17 GJD-221.1U INT RIGHT M103 1,3 FSD-2 2 CG2VF250 Front-access 10 14 10 14 17 GJD-221.1U INT RIGHT M104 1,3 FSD-2 2 CG2VF250 Front-access 12 12 12 12 17 GJD-221.1U INT RIGHT M104 1,3 TOTAL I 37 GENERAL NOTES 1) Contractor to verify all quantities and sizes before ordering. 2) Provided with one set of mounting angles. 3) Front-access with flanged sleeve in lieu of mounting angles. I 4) Minimum size=8"W x 6"H. 6x6 dampers provided with 8x6 sleeve and 6x6 duct collars. 5) • 23048 FSU List Reviles Pagel 6/9/2023 Agri! MODEL CG2 TAG: FSD-1 SD-CG2-21.04 Page 1 Combination Fire/Smoke Damper•11 Hr. Rated•Single Thickness Blade•Leakage Class II•250°F or 350°F Rated•Galvanized Steel m Standard Construction and Materials UNDERWRITERS LABORATORIES INC.® FRAME: 51/4"x N"x 16 GA.galvanized steel hat channel.Flat 16 GA. CLASSIFIED DYNAMIC FIRE AND SMOKE DAMPER galvanized steel head and sill for maximum free area on FIRE RESISTANCE RATING 1'A HR dampers g less ized ort equall 13"i high. LEAKAGE RESISTANCE CLASS II BLADES: 1 SolidsinglePlated steel stub. BEARINGS: Oil impregnated bronze. FILE#R6462 LINKAGE: Plated steel angle and crank plates with stainless steel pivots, in-jamb type or on-blade type. This combination fire/smoke damper meets the construction STOPS: 18 GA.galvanized steel angles at head and sill. and performance requirements of: BLADE SEALS: Silicone. JAMB SEALS: Stainless steel. • Underwriters Laboratories Inc.Standard 555 and 555S SLEEVE: Minimum 20 GA.galvanized steel by 18"long(sizes greater • National Fire Protection Association Standards 80,90A,92, than 84"wide or 84"high require minimum 18 GA.) 101,105 CAULKING: Hardcast irongrip 601 or UL-listed equivalent. • ICC's International Building Code ACTUATOR: Electric with heat response device(EHRD)or pneumatic with • California State Fire Marshal Listing#3224-1328:119. heat response device(PHRD).Factory-installed for Power- • New York City MEA Listing#111-99-M Open/Spring-Close(fail close)operation.External left hand • Underwriters Laboratories Inc.Approved for dual direction mounted as viewed from jackshaft side of damper. airflow and dynamic conditions. FINISH: Mill. • Underwriters Laboratories Inc.Classified for use in fire resistive ratings of less than 3 hours illimiEl Options • Underwriters Laboratories Inc.Classified for use in smoke Exact size(no undercut) control systems for Leakage Class II and 250°F or 350°F. Actuators-120V,24V,230V or Pneumatic • Actuators must be arranged to operate automatically, Right hand and/or internal actuator mounting locations(restrictions apply) must fail dosed upon loss of power,and must be Dual Position Indication(DPI)Switches controlled by a smoke detection system. Sensotherm Re-Openable Heat Response Device(ESOT)for electric actuators Sensatherm Re-Openable Heat Response Device(EPOT)for pneumatic actuators Model SM-501 flow-rated smoke detector The 3"dimension will Model 2151 no-flow smoke detector(12"minimum damper height) /\ increase if sleeve length Momentaryo testb switch 1111IK' ,- is increased.tRemota test boxes ,Copper tubing(for pneumatic actuators) - `,� Transformers i• I \ Tab-lock retaining anglesg -1 or 2 Sets /�j I`I ii ' Stainless steel bearings ��;`,,�1�I !r►.. `, Stainless steel axles I, S \, Security bars Height • \ !" Sleeves of various depths and gauge thickness(restriction apply) 9 I �II \, " ' No sleeves(restriction apply) I \�` r Round or oval transitions `��� Short-width(less than 8")and/or short-height(less than 6")transitions /� �' \ - tttttt�ii ... Notes / 4 1. Damper frames are provided approximately Y."undercut.The addition of a sleeve will v• - I\ ; increase the size of the assembly. 2. Dampers greater than or equal to 12"in height with factory mounted SM-501 smoke detectors l require a minimum 19"deep sleeve(10'/:"on the actuator side);detectors will be mounted on the o76 �`� r 52 ' side of damper opposite actuator. �`�./- 3. Dampers less than 12"in height with factory mounted SM-501 smoke detectors require a n -0' "� \\ I\-G/`!/' minimum 20"deep sleeve(11%"on the actuator side).Detectors will be mounted on the bottom 1 p,T• or top of damper. Blade Profile 4 Smoke detectors can be ordered for field mounting with standard 1S"deep sleeve. t See Note 6 for details 5. Dampers for horizontal installation can only be mounted in a fire barrier constructed of masonry/concrete materials. S z rig Chart Notes 6. Unless ordered with a smoke detector,the 3"sleeve setback on the non-jackshaft side will "Dampers smaller than the minimum frame size require a increase when sleeve lengths greater than 18"are ordered.Custom non-jackshaft side setback transition. Reference SD-TRFS for details. dimensions must be specified on order.When ordered with a smoke detector,additional sleeve ""For damper sizes smaller than 8"W x 3"H,airfoil blades length is added to jackshaft side.If ordered with smoke detector and additional sleeve length will be supplied. (beyond requirements of notes 2 and 3),additional sleeve length will be added to jackshaft side "Fora true 6"high,width is limited to 16".When ordered as 6"high and width is greater than 16",an 8"high damper with unless custom setback dimension is otherwise specified on order. 2°short-height transition will be supplied. Damper Sizes 2000 fpm,4 in.wg 3000 fpm,4 in.wg Orientation Horz 8 Vert Horizontal Vertical Horz 8 yen Horizontal Vertical Panels •" Max Panel Max Assy Max Panel Max Panel Max Assy Max Assy Max.Panel Max Assy Max Assy Min Panel 250°/350' 250°/350' 250' 350' 250' 350° 250° 250° 250° Rectangular 4"W x 4 H 36"W a 48"H 72"W x 48"H 36'W x 48"H 36"W x 48'H 144"W x 70"H 128"W x 62"H 36"W x 36"H 72"W x 36'H 108"W x 36'H (8"W x 6"H frame) Round 4"dia. 34"dia. 46"dia. 34'die. 34"dia. 68"dia. 60"dia. 34"dia. 34"dia. 34"dia. (8"W x 61H frame) Oval 4"W x 4"H 34°W a 46"H 70"W a 46"H 34"W x 46"H 34"W x 46"H 45 sq.ft.or 106"W x 60"H 34"W x 34"H 70"W x 34"H 106 W x 34"H (8"W x 6"H frame) 106"W x 68"H In the interest of product development,Cesco Products reserves the right to make changes without notice. OP 450 Riverside Dr•Wyalusing PA, 18853 orolsron of Mes e, Phone:570-746-1888•Fax:570-746-9286 Member of AMCA www.cescoproducts.com CES-21-01-05 I April 2021 MODEL CG2 SD-CG2-21.04 Page 2 Combination Fire/Smoke Damper• 1% Hr.Rated•Single Thickness Blade•Leakage Class II•250`F or 350°F Rated•Galvanized Steel in Operational Ratings Maximum Differential Pressure: 4 in.w.g. Maximum Face Velocity: 2000 fpm(3000 fpm for selected size/actuator combinations) - Leakage Ratings UL Leakage Class II 10 cfm per sq.ft.maximum @ 1 in.wg 20 cfm per sq.ft.maximum @ 4 in.wg Sound Ratings The Noise Criterion data below was tested in accordance with ASTM E477.99 in the center octave band. Noise Criterion(NC) Damper Velocity(fpm) Size 1000 2000 3000 4000 12"W x 12"H 31 53 64 71 24"W x 24"H 33 54 65 - Pressure Drop Ratings The pressure drop data shown below is based on laboratory conditions.The test setup does not take into account elbows or other duct fittings that are part of every actual duct system.The configuration of the actual duct system immediately upstream and downstream of the damper often contributes more pressure loss than the damper itself. 1.000 i ^A r i (249) i` `M �' W RlD D E . ',�; RATIAGS E - , ' ' ' AIR ., 1. / This product was tested PERFORRIRRCE ++1',e.y i in accordance with AMCA Q tia + y^ry�i Standard 500D,Figure 5.3. s� � AIR 0 Y MOVE1nERT Sr. i Intake air converted to nnn conrnor 4g0 w ch 0.100 standard air density. nssocIRTlon °•o C ; (24.9) IRTERnfTICRRE.MC.''' 9 Casco Products certifies N that the CG2 damper shown here is licensed to bear the AMCA seal. The ratings shown are based on tests / and procedures performed in accordance with AMCA Publication 511 and comply / with the requirements of i the AMCA Certified Ratings Program.The AMCA (2.49) i i, 0.010 . ' Certified Ratings Seal . 200 1000 5000 applies to Air Performance (1.0) (5.1) (25.4) Ratings only. Face Velocity FPM(m/s) -a :. r Horizontal Vertical 250°F 350°F Velocity Pressure Item# Qty Damper Size Orientation Temp. Rating Operational Rating Union Made Arch./Eng.: EDR: I ECN: I lolz Contractor: Project: Date: I 1 DWN:I DWG: I 450 Riverside Dr•Wyalusing PA,18853 41-' / Division ol Meslek Phone:570-746-1888•Fax:570-746-9286 ',wan'''. Member of AMCA www.cescoproducts.com CES-21-01-05 May 2022 MODEL CA2GF TAG: FSD-2 SD-CA2GF-22.05 Page 1 Combination Fire/Smoke Damper•11/2 Hr.Rated•Airfoil Blade•Leakage Class II•250°F or 350°F Rated•Front Grille Access•Galvanized Steel Standard Construction and Materials UNDERWRITERS LABORATORIES INC.® FRAME: 5'/z"x%."x 16 GA.galvanized steel hat channel. CLASSIFIED DYNAMIC FIRE AND SMOKE DAMPER BLADES: 20 GA.galvanized steel,double skinned(equal to 14 GA.), FIRE RESISTANCE RATING 114 HR parallel action LEAKAGE RESISTANCE CLASS II AXLES: Square plated solid steel stub. 41) BEARINGS: Oil impregnated bronze. FILE#R6462 LINKAGE: Plated steel angle and crank plates with stainless steel pivots, in-jamb type. This combination fire/smoke damper meets the construction STOPS: 20 GA.galvanized steel angles at head and sill and performance requirements of: BLADE SEALS: Silicone. JAMB SEALS: Stainless steel. •Underwriters Laboratories Inc.Standards 555 and 555S SLEEVE: 20 GA.galvanized steel by 15"long(1'/s"grille clearance) •National Fire Protection Association Standards 80,90A,92, or 17"long(3Y5"grill clearance)with"/,."front flange. 101, 105 CAULKING: Hardcast Irongrip 601 or UL-listed equivalent. •ICC's International Building Code ACTUATOR: Electric with heat response device(EHRD)or pneumatic •New York City MEA Listing#111-99-M with heat response device(PHRD),factory-installed for •California State Fire Marshal Listing#3225-1328:118 Power-Open/Spring-Close(fail close)operation,internally •Underwriters Laboratories Inc.Approved for dual direction mounted and accessible from grille side. airflow and dynamic conditions. FINISH: Mill or galvanized steel. •Underwriters Laboratories Inc.Classified for use in fire resistive ratings of less than 3 hours. Options •Underwriters Laboratories Inc.Classified for use in smoke Integral Dual Position Indication(IDPI)Switches control systems for Leakage Class II and 250°F or 350°F. Sensotherm Re-Openable Heat Response Device(ESOT)for Electric Actuator •Actuators must be arranged to operate automatically, must Sensotherm Re-Openable Heat Response Device(ESOP)for Pneumatic Actuator fail closed upon loss of power,and must be controlled by a Model SM-501 Flow-rated smoke detector smoke detection system. -Shipped Loose Model 2D51 No-flow smoke detector(14"Minimum Damper Height) Fire Rated Tab-Lock retaining angles Partition Factory Installed Stainless steel bearings Insulation Copper tubing(for Pneumatic Actuators) 3 Sides When Wall Sleeves of various gauge thicknesses Mounted, Round or oval transitions 4 Sides When Floor Short-width(less than 10")and/or short-height(less than 10")transitions i I Mounted 1..1.1 Notes 1 1. Damper frames are provided approximately''%"undersized.The addition of a sleeve and insulation will increase the size of the assembly. See II-FAGM for sizing ��� x openings. P 2. Damper with smoke detector must have a minimum sleeve of 16"(1'/"setback) or 18"(3"setback). 3. Dampers for horizontal installation can only be mounted in a fire barrier constructed of masonry/concrete materials. 01• °�_ Damper Sizes 4Y�� 2000 fpm,4 in.w.g. 4000 fpm,6 in.w.g. I-2", o Orientation Hor&Vert Hor&Vert Hor&Vert j °°�� Panel Min Panel Max Panel Max Panel j a 0 10"W x 8"H '� Rectangular 32"W x 42"H 24"W x 20"H I/ 1 (10"W x 8"H frame) — Round 6"die. 30"dia. 18"dia. Grille - N. (10"W x 8"H frame) f by Opening Size Oval 8"V1r x 6"H Others 30"W x 40"H 22"W x 18"H (10"W x 8"H frame) 'Dampers smaller than minimum frame size require a transition. Reference SD-TRFS. w — 17"Deep When 3%"Clearance _..` 15"Deep When 1%"Clearance For handwritten orders,use the schedule block on page 2. In the interest of product development,Cesco Products reserves the right to make changes without notice. 450 Riverside Dr•Wyalusing PA,18853 Division of Mestek Phone:570-746-1888•Fax:570-746-9286 Member of AMCA www.cescoproducts.com CES-21-01-15 May2022 MODEL CA2GF SD-CA2GF-22:05 Page 2 Combination Fire/Smoke Damper•11/2 Hr.Rated•Airfoil Blade•Leakage Class II•250°F or 350°F Rated•Front Grille Access•Galvanized Steel ▪ Operational Ratings Maximum Differential Pressure:4 in.w.g. Maximum Velocity:2000 fpm ▪ Leakage Ratings UL Leakage Class II 10 ctrn per sq.ft.maximum @ 1 in.w.g. 20 cfrn per sq.ft.maximum @ 4 in.w.g. Pm Pressure Drop Ratings The Pressure drop data shown below is based on laboratory conditions.The test setup does not take into account elbows or other duct fittings that are part of every actual duct system.The configuration of the actual duct system immediately upstream and downstream of the damper often contributes more pressure loss than the damper itself. 1.000 , , (249) /' / / ,// Sizes listed on this chart exceed the size limitations of the CA2GF. These sizes are based on the t. model CA2 approval. 40 o, .�+ m PP • a q 0.100 a 3 (24.9) o / / N l''/' / e r/ , / / / /// / // / (2.49) /4/ :/// 0.010 , • 100 1000 5000 (0.508) (5.08) (25.4) Face Velocity FPM(m/s) This product was tested in accordance with AMCA Standard 511. Intake air converted to standard air density. n_ _, / i)l .o ii.\ ' Horizontal Vertical 250°F 350°F Velocity Pressure . ;� Item# Qty Damper Size Orientation Temp. Rating Operational Rating Union Made Arch./Eng.: EDR: ) ECN: Job: Contractor: Project: Date: DWN: DWG: 450 Riverside Dr•Wyalusing PA, 18853 Division of Mes[ek Phone:570-746-1888•Fax:570-746-9286 Member oIAMCA www.cescoproducts.com I A(i: I-SD-1I ' September2018 Tab-Lock Retaining Angles SI-TLRA-18.09 Page 1 Fire Damper Models: 119, 117, 15S, 17S,D19, D17, 15D, 17D,319,317,30S,38S,D39,D37,30D,38D,MD19, MD17, 15MD, 17MD,MA19, MA17, 15MA, 17MA, MD39,MD37,30MD,38MD,MA39,MA37,30MA,38MA Fire/Smoke Damper Models:FS,AS, CG,MS,FA, UA,CA,MA,FT,AT,CH,MT,TA,VA,CT,LA APPLICATION Tab-Lock Retaining Angles may be used to mount fire dampers or fire/smoke dampers both vertically and horizontally. UL approved for dampers with 1'and 3 hour fire rating,they offer the flexibility of attachment to the sleeve into the rated barrier. The corner tabs can be bent 90°in either direction before or after attachment to the sleeve,depending on job site preference. Tab-Lock Retaining Angles are pre-punched for easy attachment to the sleeve. Refer to the appropriate Installation Instruction for details. NOTES Material: 16 GA.galvanized steel. Dimensions: 1%"x W Orientation: Vertical or horizontal Angles are pre-punched and shipped loose for field attachment to the sleeve. Refer to the appropriate Installation Instructions for details. This combination fire/smoke and fire damper meets the construction and performance requirements of: • Underwriters Laboratories Inc. • ICC's International Building Code • SMACNA • National Fire Protection Association Standard 90A 'A"dia.Holes 6" Maximum O.C. Minimum 2 per Side 1k-. 11111 jillr 1 RESTEK,INIC. &LouP�� gNgi air balanceCffs 0uwTED 450 Riverside Rd•Wyalusing PA, 18853•Phone 570-746-1888•Fax 570-746-9286 INDUSTRIES T MCDLG-23-02-03 ITAG: FSD-1I March 2021 SI-ACTLOC-2.1.03 ' Life-Safety Damper Actuator Locations For all Models of Combination FireSmoke and Smoke Dampers Page, SCOPE Per UL 555 and UL 555S, "Actuators shall be factory-mounted securely in position". Depending on the size of the assembly,there may be a combination of primary and secondary actuators.This document will provide details as to where these actuators will be located based on the configuration you have ordered, as well as detail what is provided by the factory in terms of wiring. PRIMARY ACTUATORS Each damper has at least one primary actuator("P"on drawings).This actuator must be connected by the electrical contractor. The primary actuator contains the heat response device(s). Refer to SD-EHRD or SD-PHRD for additional information on heat response devices. By selecting external left(EL)or internal right(IR),you are selecting where the primary actuator will be located when viewed from the jackshaft side of the damper. P P External Left Internal Right (EL) (IR) If your application calls for the actuator to be on the opposite side of the damper-external right or internal left(ER or IL)- MCDLG approvals allow for the damper to be flipped 180°, such that the top of the damper is the bottom and vice versa, to achieve the opposite mounting location. P I7 Flip 180° External Left(EL) External Right(ER) P P Flip 180° U Internal Right(IR) Internal Left N ``' Commercial Damper ® &Louver Group Agcow air balance 450 Riverside Rd•Wyalusing PA, 18853•Phone 570-746-1888•Fax 570-746-9286 INDUSTRIES 7 f® MCDLG-23-20-04 ITAG: FSD-1I ' August 2021 II-CDLG-FSOS-21.09 Supplemental Instructions For One Side Retaining Combination Fire/Smoke Damper Models: FS, MS, CG, AS, FA, MA, CA, UA Fire Damper Models: MD19, 17MD, 15MD, MD17, MA19, 17MA, 15MA, MA17, 119, 17S, 15S, 117, D19, 17D, 15D, D17 Page 1 APPLICATION This supplemental instruction is to be used as a supplement to II-FS(replacing Note 6 on page 2)and II-FD (replacing Note 6 on page 2).The method described by these instructions is an alternate method of mounting classified dampers within a fire barrier using perimeter retaining angles on only one side of the barrier. NOTES: 1. One side retaining angles are only available for bafflers rated for less than three hours. 2. Reference Table 1 for vertical installation allowable sizes and Table 2 for horizontal installation allowable sizes. 3. The closed plane of the blades must be within the plane of the wall. 4. For horizontal installations,the actuator must be on the top side of the floor. 5. Perimeter retaining angles shall increase in size,proportionately,so there will be a minimum of 1"overlap on the wall,including at the corners. 6. The angles shall be attached to both the damper and the barrier framing on all four sides of the barrier face. 7. The leg attached to the damper can turn away from or into the opening,so long as expansion clearance is properly maintained. 8. In metal frame construction(vertical installation only),the angles can be mounted under or over the gypsum board.In wood frame construction (vertical installation only),the angles must be mounted over the gypsum board. 9. The perimeter retaining angles shall be fastened to the damper with'/,."diameter steel or stainless steel nuts and bolts or by tack welding with beads%"±'/'in length or with#10 steel or stainless steel sheet metal screws or steel or stainless steel pop rivets.All connections shall be spaced on 6"maximum centers and 3"maximum from each corner(a minimum of 2 fasteners are required per side). 10. For vertical installations,perimeter retaining angles shall be fastened to the barrier on 6"maximum centers and 3"maximum from each corner (a minimum of two fasteners are required per side).For horizontal installations,perimeter retaining angles shall be fastened to the barrier on 12" maximum centers and 6"maximum from each corner(a minimum of one fastener is required per side). A.In masonry construction,'/,."diameter"tapcon"or equal fasteners with a minimum of 1W penetration are required. B.In metal framed openings,fine thread drywall screws with a minimum of 1"penetration into the framing are required. C. In wood framed openings,course thread drywall screws with a minimum of 1"penetration into the framing are required. 11. Perimeter retaining angles shall be a minimum of 1%"x'/"x 16-GA steel. 12. Corners of angles are not welded together for dampers with width or height dimensions exceeding 24".For dampers 24"W x 24"H or smaller,the corners of the perimeter mounting angles can be welded.Some local codes may not allow welded corners. 13. Perimeter retaining angles and their mounting fasteners are not typically supplied with the damper. 14. Attachment of these angles must not restrict operation of the damper. ONE SIDE SIZE LIMITATIONS Table 1:Vertical Installation Table 2:Horizontal Installation Construction Construction Masonry Metal Frame Wood Frame Masonry FS1,FS2,MS1, 108"W x 44"H 1 08"W x 44"H 36"W x 48"H FS1,FS2,MS1, MS2,CG1,CO2, or or or MS2,CG1,CG2, 36"W x 42"H AS1,AS2 44'W x 70"H 44"W x 70"H 48"W x 36"H AS1,AS2 FA1,FA2,MA1, 108'W x 44"H 108"W x 44"H 36"W x 48"H FA1,FA2,MA1, MA2,CA1,CA2, or or or MA2,CA1,CA2, 32"W x 42"H a UA1,UA2 44"W x 96"H 44"W x 96"H 48"W x 36"H C UA1,UA2 n 108"W x 44"H 108"W x 441H 36"W x 48"H 6 MD19,17MD, or or or E MD19,17MD, z 15MD,MD17 q4"W x 60"H 44"W x 60"H 48"W x 36"H Z 15MD,MD17 36"W x 42"H m o MA19,17MD, 64"W x 36"H 64"W x 36"H 48"W x 36"H g MA19, 17MD, 32"W x 42"H 15MD,MD17 15MD,MD17 108"W x 44"H 108"W x 44"H 36"W x 48"H 119,17S,15S, 119,17S,15S, or or or 117 36'W x 42"H 117 44'W x 108"H 44"W x 108"H 48"W x 36"H D19,17D,15D, 36"W x 36"H D19, 17D, 15D, 72"W x 44"H 72"W x 44"H 36"W x 36"H D17 D17 L omm.r<i.Iro Dop INC. U i 8 Louver G O N erg air balance 6/4,.,._ 111 T 'o LJ 450 Riverside Rd•Wyalusing PA, 18853•Phone 570-746-1888•Fax 570-746-9286 MCDLG-23-02-11 August 2021 II-CDLG-FSOS-21.09 ' Supplemental Instructions For One Side Retaining Combination Fire/Smoke Damper Models: FS, MS, CG, AS, FA, MA, CA, UA Fire Damper Models: MD19, 17MD, 15MD, MD17, MA19, 17MA, 15MA, MA17, 119, 17S, 15S, 117, D19, 17D, 15D, D17 Paget Vertical.One Side Retaining,Masonry Horizontal. One Side Retaining.Masonry Retaining Angle Retaining Angle Overlap Overlap Retaining Angle Expansion Overlap . Clearance Duct Connector 16"Maximum i Actuator Side FIME i � I u Air Flow I l Perimeter I I Retaining Side 6"Maximum Duct iihi. Non-Actuator Connector I Expansion Side Clearance MIAir Flow 16"Maximum 6"Maximum Actuator Side Non-Actuator Side Vertical.One Side Retaining.Metal Stud Vertical.One Side Retaining.Wood Stud Retaining Angle Retaining Angle r Overlap �, Overlap ;J; t %, % Expansion ��; r Expansion Clearance ' 1 Clearance 46. �J (� Duct Connector �� Duct Connector Air Flow Air Flow hih Perimeter 1-' Perimeter !I Retaining Side ��Imie Retaining Side ir ihk. kihhik. ;1';'' 16"Maximum 6"Maximum 16"Maximum 6"Maximum Actuator Side Non-Actuator Actuator Side Non-Actuator Side Side `� e� Commercial D_ammper &Louver Group •mow air balance ''^^ In the interest of product development,Mestek CDLG reserves the right to make changes without notice. m�uoxas LJ 450 Riverside Rd•Wyalusing PA, 18853•Phone 570-746-1888•Fax 570-746-9286 MCDLG-23-02-11 March2019 INSTALLATION INSTRUCTION TAG: FSD-1 II-FS-19.03 Standard Installation Page 1 Combination Fire/Smoke Damper Models:AS1,FS1,CG1,MS1,AS2,FS2,CG2,MS2,AT1,FT2,CH1,MT1,AT2,FT2,CH2,MT2, UA1,FA1,CA1,MA1,UA2,FA2,CA2,MA2,VA1,TA1,CT1,LA1,VA2,TA2,CT2,LA2,AS2C2,FS2C2,TG2C2,MS2C2,UA2M,FA2M,CA2M,MA2M,VA2M,TA2M,CT2M,LA2M Fire Damper Models:MD17,MD19,15MD,17MD,MS17,MS19,15MS,17MS,MD37,MD39,30MD,38MD,MA17,MA19,15MA,17MA,MA37,MA39,30MA,38MA APPLICATION These dynamically rated fire/smoke and static or dynamic rated fire dampers are intended to restrict the passage of flame.The dynamically rated fire/smoke dampers are also intended to restrict the passage of smoke.When the damper is intended to be used as a fire rated damper,the standard installation requires that the damper is positioned so that the closed plane of the blades is within the fire rated masonry/concrete or metal or wood framed gypsum wallboard barrier.When the damper is to be used as a leakage rated damper only,the damper is to be installed within 24"of the smoke barrier and upstream of any duct outlets.When configured as modulating("), the damper may be utilized as a volume control damper.This damper may be mounted in the vertical or horizontal position with the damper blades running horizontally. Airflow can be from either direction.When mounted in the vertical position,the damper may be mounted right side up or upside down and can be mounted in a fire barrier constructed of masonry/concrete or metal or wood framed gypsum wallboard materials.When mounted in the horizontal position,the damper must be mounted with the actuator on the top side of the floor and can only be mounted in a fire barrier constructed of masonry/concrete materials.Models AS2C2,FS2C2,TG2C2,and MS2C2 are approved and labeled for use in the following applications.For sizes not exceeding 24'W x 24"H,Models AS2C2,FS2C2,TG2C2,and MS2C2 are approved and labeled for use as vertically mounted or horizontally mounted,1%hour rated Fire/Smoke Dampers.When used as Fire/Smoke Dampers,the installation instructions slated in this pamphlet apply.Models AS2C2,FS2C2,TG2C2,and MS2C2 are also approved and labeled for use as horizontally mounted,1 hour rated Corridor Dampers.When used as a Corridor Damper,the installation instructions stated by II-FS2C shall apply. MULTIPLE PANEL SIZE LIMITATIONS Actuation Electric Orientation Horizontal Mount Vertical Mount Assembly Max Panel Max Assy 250° Max Assy 350° Max Panel Max Assy 250° Max Assy 350° AS1,FS1,CG1,MS1, 36"Wx48"H 72"Wx48"H 72"Wx48"H 36"Wx48"H 144"Wx70"H 128"Wx62"H AS2,FS2,CG2,MS2 48"Wx36"H All,FT1,CH1,MT1, 30 Wx48"H 60"Wx48"H 60"Wx48"H 36 Wx48"H 126"Wx48"H 126"Wx48"H AT2,FT2,CH2,MT2 36"Wx30"H 42"Wx36"H UA1,FA1,CA1,MA1, 32"Wx48"H 96'1/1/x96"H 96'Wx96"H 32"Wx48"H 128"Wx96"H 128"Wx96"H UA2,FA2,CA2,MA2 vA1,TA1,cT1,LA1, 30"Wx48"H 60"Wx48"H 60"Wx48"H 30"Wx48"H 60"Wx48"H 60'Wx48"H VA2,TA2,CT2,LA2 AS2C2,FS2C2, 24"Wx24"H 24"Wx24"H - 24"Wx24"H 24"Wx24"H TG2C2,MS2C2 •uA2M,•FA2M, 24"Wx24"H 96"Wx46"H - 24"Wx24"H 96"Wx48"H *CA2M,•MA2M - 'VA2M,`TA2M, 24"Wx24"H 60"Wx48"H - 24"Wx24"H 60"Wx48"H `CT2M,•LA2M Actuation Pneumatic Orientation Horizontal Mount Vertical Mount Assembly Max Panel Max Assy 250° Max Assy 350° Max Panel Max Assy 250° Max Assy 350° AS2,FS2,CG2,MS1,AS2,FS2,CG2,MS2 36"Wx48"H 72"Wx48"H 72"Wx48"H 36"Wx48"H 108'Wx48"H 108"Wx48"H All,FT1,CH1,MT1, 30"Wx48"H 60"Wx48"H 60"Wx48"H 36"VVx46"H 126"Wx48"H 126"Wx48"H AT2,FT2,CH2,MT2 36"Wx30"H 42"Wx36"H UA1,FA1,CA1,MA1, 32"Wx48"H 96"Wx96"H 96"Wx96"H 32"Wx48"H 128"Wx96"H 128"Wx96"H UA2,FA2,CA2,MA2 VAI,TA1,C71,[Al, 30"Wx48"H 60"Wx48"H 60"Wx48"H 30"Wx48"H 60"Wx48"H 60"Wx48"H VA2,TA2,CT2,LA2 Actuation Non-Motorized Orientation Horizontal Mount Vertical Mount Assembly Max Panel Max Assy 250° Max Assy 350° Max Panel Max Assy 250° Max Assy 350° MD17,MD19, 36"Wx48"H 72"Wx48"H 72"Wx48"H 36"Wx48"H 72"Wx60"H 72"Wx60"H 15MD,17MD 126"Wx48"H 126'Wx48"H MS17,MS19, - - 36"Wx48"H 156"Wx96"H 156"Wx96"H 15MS,17MS - M037.MD39, 30"Wx48"H 60"Wx48"H 60"Wx48"H 36"Wx48"H 126"Wx48"H 126"Wx48"H 30M0,38MD 36"Wx30"H MA17,MA19, 64"Wx36"H 64"Wx36"H 64'Wx36"H 64"Wx36"H 15MA,17MA 32"Wx48"H 32"Wx72"H 32"Wx72"H 32"Wx48"H 32"Wx72"H 32"Wx72"H MA37,MA39, 32"Wx48"H 60"Wx36"H 60"Wx36"H 32"Wx48"H 60"Wx36"H 60"Wx36"H 30MA,38MA *Modulating SUPPLEMENTAL INSTALLATION INSTRUCTIONS/SUBMITTAL DATA One-Side Retaining Angles(SI-CDLG-FSOS) Electric or Pneumatic Heat Response Device Out-of-Wall/Floor(SI-CDLG-OOWFD) (SD-EHRD or SD-PHRD) Sleeve Extension(SI-CDLG-SLVEXT) Flow-Rated Smoke Detector(SM-501) 4s �. 'Ne Transfer Openings(SI-GFTD) No-Flow Smoke Detector(2151) e Gommemal Damper Integral Dual Position Indication(SD-IDPI) Transitions(SD-TRFS) &Louver Gmup Electric or Pneumatic Sensotherm Sleeves(SD-SLVFS) p tar, airbalance alance ,^ (SO-ESOT or50.P50T) "0 5°� a L' / 450 Riverside Rd•Wyalusing PA, 18853•Phone 570-746-1888•Fax 570-746-9286 MCDLG-24-02-02 March 2019 INSTALLATION INSTRUCTION II-FS-19.03 INSTALLATION INSTRUCTIONS Page 2 1.General:The installation of the damper and all duct connections to the damper sleeve shall conform to NFPA-90A and the SMACNA Fire, Smoke and Radiation Damper Installation Guide.All duct connections shall also conform to UL555 when the damper is intended to be used as a fire damper. 2.Actuators:Dampers must be supplied with factory mounted actuators(except Model MD17, MD19, 15MD, 17MD,MS17, MS19, 15MS, 17MS, MD37,MD39,30MD,38MD, MA17,MA19, 15MA, 17MA, MA37, MA39,30MA,and 38MA)and are intended to close automatically when sensing heat or upon loss of electrical power or release of air pressure.When this damper is used as a leakage rated damper only, it shall be arranged to operate automatically and is to be controlled by a smoke detector.Refer to additional instructions,which detail damper actuator sequence of operations. Multiple actuators in a mechanically linked section that are factory wired/plumbed together have only one heat response device and one supply connection point.The supply connection point must be at the"master"actuator package,which contains the heat response device.The heat response device must be wired/plumbed between the supply connection point and the master actuator and all slave actuators.Refer to SI-ACTLOC for further details. 3.Multiple Panel/Multiple Section Assembly:Large damper assembly sizes may require multiple factory assembled modules that ship separately.Refer to page 5 for details. 4.Sleeves: Sleeves are rewired for the proper installation of fire rated dampers.but need not be factory mounted. Dampers with factory mounted external actuators can be supplied without sleeves,but require sideplates.Dampers with factory mounted internal actuators can be supplied without sleeves or sideplates.Sleeves shall be the same gauge or heavier as the duct to which it is attached.Gauges shall conform to SMACNA or ASHRAE duct standards.A field supplied sleeve is attached to the damper frame with%8"diameter steel rivets,'A"diameter steel bolts,#10 steel sheet metal screws,or'/,"long welds.Fasteners shall be staggered on each side of the damper frame on 6"maximum centers and 3'W"maximum from each corner. For Class I Fire/Smoke dampers,approved caulking(reference note 7)shall be applied along the perimeter between the sleeve and the damper on both sides. For Class II Fire/Smoke dampers,approved caulking(reference note 7)shall be applied along the perimeter between the sleeve and the damper on only one side. 5a.Expansion Clearance:The opening in the wall for the fire rated damper shall be sized to provide expansion clearance between the sleeve and the opening.The minimum expansion clearance shall be the greater of'A"or'A"per foot of overall damper/sleeve width and height.The maximum expansion clearance shall not exceed''/"per foot of overall damper/sleeve width and height plus 2".The damper can be located anywhere in the opening and need not be centered. However,in cases of large damper assemblies,the damper must be centered in the opening such that the required expansion clearance gap does not exceed 3"on either side of the damper and the resulting larger retaining angle(see note 6)does not exceed 4".The top retaining angle is permitted to be larger than 4"given it is impractical to provide a clearance gap at the bottom of a large assembly. Example:For a damper with exact outside dimensions of 36"W x 48"H,the gap at the top plus the gap at the bottom must be between 0.5"and 2.5".The gap at the left side plus the gap at the right side must be between 0.375"and 2.375". 5b.Undercutting:Width and Height dimensions apply to the frame size and do not include the outside sleeve thickness. If ordering with a heavy gauge sleeve,care must be taken to order the damper with additional undercuts to ensure the minimum required annular space is maintained. Example: For a damper ordered as 36 x 48 with no undercut and 1 Oga sleeves will have an approximate OD of 36A"x 48%". 6.Retaining Angle Attachment:Perimeter retaining angles shall increase in size,proportionately,so there will be a minimum of 1"overlap on the wall,including at the corners.The angles shall be flush against the barrier.The leg attached to the damper can turn away from or into the opening. In metal frame construction,the angles can be mounted under or over the gypsum board. In wood frame construction,the angles must be mounted over the gypsum board.The perimeter mounting angles shall be fastened on all four sides and on both faces of the damper to the sleeve only,with Me"diameter steel or stainless steel nuts and bolts or by tack welding with beads%"t'A"in length or with#10 steel or stainless steel sheet metal screws or'%s steel or stainless steel pop rivets.All connections shall be spaced on 6"maximum centers and 3"maximum from each comer(a minimum of 2 fasteners are required per side). For perimeter angle mounting on one side of the fire barrier only,reference Installation Instruction ll-FSOS.Perimeter retaining angles shall be a minimum of 1W x Ye"x 16 GA.steel.Corners of angles are not welded together for dampers with width or height dimensions exceeding 24". For dampers 24'W x 24"H or smaller,the corners of the perimeter mounting angles can be welded. Some local codes may not allow welded corners.Attachment of these angles must not restrict operation of the damper.Perimeter retaining angles and their mounting fasteners are not typically supplied with the damper. Plain"S"Slip Double"S"Slip Inside Slip Joint Hemmed"S"Slip The factory supplied round/oval transition provides the breakaway connection if the following conditions are s < 1 �_� �� satisfied. 9 5- .) (_ f 1. Round duct diameter is no larger than 36". 2. Oval duct size is no larger than 71"W x 30"H. Standing"S"Slip Standing"S"Slip Standing"S"Slip 3. Duct gauges conform to the SMACNA or ASHRAE Standing"S"Slip (Bar Reinforced) (Angle Reinforced) (Alternate Bar) standard. 4. An oval duct or round duct less than or equal tot 24" is attached to the transition collar with#8 sheet metal screws(a minimum of 4 fasteners per connection).A round duct diameter greater than 24"is attached to the transition collar with#10 sheet metal screws(a minimum of 5 fasteners per connection). Dampers with round/oval transitions that fall outside of these restrictions must use a 4"wide drawband connection as shown in the SMACNA Fire,Smoke,and Qi�� MESIELINC. Radiation Damper Installation Guide. \` Commercial Damper 507 &Louver Group VV' air balance 'n In the interest of product development,Mestek CDLG reserves the right to make changes without notice. plus emuian CjimLJ 450 Riverside Rd•Wyalusing PA, 18853•Phone 570-746-1888•Fax 570-746-9286 MCDLG-24-02-02 March2019 INSTALLATION INSTRUCTION II-FS-19.03 INSTALLATION INSTRUCTIONS Page 3 (Continued from Page 2) 7.Caulking:Caulk that is exposed to the airstream(ie on the inside of the damper sleeve)shall be one of the following:Dow Coming RTV732, Silco Sil-Bond RTV 4500,General Electric 15808,or Novagard RTV300. Breakaway flange caulking shall be Design Polymeric's DP1010 or Precision's PA2084T.Caulk that is not exposed to the airstream(ie on the outside of the damper sleeve)can be of any type that is certified(UL Classified)to have a flame/smoke developed index of 25/50 or less(re:UL723)and is approved by the local authority having jurisdiction.Caulking is allowed on any external/exposed portions of the damper sleeve,but is not permitted to be in the annular space between the fire barrier and the damper sleeve. 8.Duct Connections:All connecting ducts shall not be continuous,but shall terminate at the fire damper sleeve.Duct connections not listed as breakaways shall be considered rigid.For rigid type duct connections,the sleeve shall be a minimum of 16 GA.on dampers not exceeding 36"wide or 24"high or 24"diameter and 14 GA.on larger units. Maximum sleeve thickness shall not exceed 10 GA.galvanized steel. Dampers supplied with thinner sleeves require a breakaway connection.The following breakaway duct-to-sleeve connections may be used: Plain"S"Slip,Double"S" Slip, Inside Slip, Hemmed"S"Slip,Standing"S"Slip,Standing"S"Slip(Bar Reinforced),Standing"S"Slip(Angle Reinforced),and Standing"S" Slip(Alternate Bar).Breakaway joints shall have no more than two No. 10 sheet metal screws on each side and on the bottom.The screws shall penetrate both sides of the slip pocket.When a breakaway joint is used along the top and bottom duct connection,a flat drive slip no longer than 20 inches is permitted on the two sides.The damper is normally supplied with a factory attached sleeve(see Note 4 when field supplied sleeve).The standard factory supplied sleeve is 20 GA.galvanized steel(18 GA.on dampers wider or higher than 84")and assumes that a breakaway type duct connection will be employed. 9.Maintenance:Dampers shall be maintained at intervals as stated in NFPA 90A and 92A.Local codes or building conditions may require more frequent inspections and maintenance.A duct access door is to be located on the jackshaft side of each damper for periodic inspection and maintenance.Access to the damper shall be provided and be large enough to allow for inspection and maintenance.For small duct size,a removable duct may be necessary.The access is to be located on the jackshaft side of the damper.After the damper is installed, it shall be cycled and inspected to insure proper operation. Periodic Inspection and Performance Testing: Although the required frequency of this periodic operation testing varies by local jurisdiction, most local requirements reference one of two national standards,either NFPA 80 or NFPA 105. NFPA 80 covers the requirements for fire dampers and NFPA 105 covers the requirements for smoke dampers.Both documents contain the following frequency requirements for periodic operation testing: Each damper shall be tested and inspected one year after installation.The test and inspection frequency shall then be every 4 years,except in hospitals,where the frequency shall be every 6 years. Performance Testing Depends On Site Requirements. A recommended procedure follows; • A.Visually confirm that the damper is in the full open position. • B.Ensure that all obstructions, including hands,are out of the path of the damper blades and then remove electric power or air • pressure from the actuator to allow the actuator's spring return feature to close the damper. • C.Visually confirm that the damper closed completely. • D.Reapply electric power or air pressure to reopen the damper. • E.Visually confirm that the damper is in the full-open position. NOTE: If lubrication is applied,it shall be of a dry type. 0-- YI Commercial Damper 8 Louver Group Aux o air balance - 'wia.wes T— _ 450 Riverside Rd•Wyalusing PA, 18853•Phone 570-746-1888•Fax 570-746-9286 MCDLG-24-02-02 March2019 INSTALLATION INSTRUCTION II-FS-19.03 ' Page 4 STANDARD MOUNTING DETAILS Vertical.2-Side Retaining. Masonry Horizontal.2-Side Retaining.Masonry Retaining Angle Retaining Angle Overlap Overlap (See Note 6,Page 2) (See Note 6,Page 2) 1 Expanse Clearance 16"Maximum Perimeter (See Note 5,Page 2) Actuator Side Retaining Angle (See Note 6,Page 2) Duct ConnectorMil ' (See Note 8,Page 3) iIII Ii .AirflowII Perimeter Retaining Angle (See Note 6,Page 2) hhion Airflow 6'Maximum Non-Actuator Side Mil-- Duct Connector (See Note 8,Page 3) Expanse Clearance 16"Maximum 6"Maximum (See Note 5,Page 2) Actuator Side Non-Actuator Side *When floor mounted,the actuator is to be mounted on the top side. Exception:Model FA,CA,MA,and UA can have the actuator mounted below the floor as well,for dampers no larger than 32"wide by 36"high. Vertical.2-Side Retainina. Metal Stud Vertical.2-Side Retaining.Wood Stud Retaining Angle Retaining Angle Overlap Overlap Expanse r(See Note 6,Page 2) [(See Note 6,Page 2) ;J Clearance + % Expanse Clearance r % (See Note 5, '. ......�--- Page 2) _4 (See Note 5,Page 2) i Duct ConnectorDuct Connector (See Note 8,Page 3) I, (See Note 8,Page 3) 1Ai flo�Perimeter PerimeterAngle Retaining Angleifl(See Note 6,Page 2) (See Note 6,Page 2)IF) ' , Ihillbe. -. 16"Maximum 6"Maximum 16"Maximum 6"Maximum Actuator Side Non-Actuator Actuator Side Non-Actuator Side Side Commercial Damper &Louver Group ' air balance ''^^ In the interest of product development,Mestek CDLG reserves the right to make changes without notice. /��a9r�:—r V 450 Riverside Rd•Wyalusing PA,18853•Phone 570-746-1888•Fax 570-746-9286 MCDLG-24-02-02 Marth2019 INSTALLATION INSTRUCTION II-FS19.03 MULTIPLE PANEL/MULTIPLE SECTION INSTALLATION DETAILS Page 5 Combination Fire/Smoke Dampers(Non-modulatina) 1. Damper assemblies ordered without factory mounted sleeves are limited in size,so that the entire assembly ships as a single section. 2. Multiple panel high damper assemblies are electrically/pneumatically,but not mechanically linked between top and bottom panels If assembled within a common sleeve.Large sizes may require multiple sleeve sections-multiple sleeve sections are not mechanically or electrically/pneumatically linked. 3. Multiple panel wide damper assemblies are mechanically and electrically/pneumatically linked if assembled within a common sleeve.Large sizes may require multiple sleeve sections-multiple sleeve sections are not mechancially or electrically/pneumatically linked. 4. Damper assembly sections that are not mechanically or electrically/pneumatically linked each have their own heat response device and their own supply connection point,such that they operate independently.Multiple actuators within a linked section are factory wired/plumbed together. 5. Damper assembly sections that are mechanically and electrically/pneumatically linked share a single heat response device and a single supply connection point. Multiple actuators within a linked section are factory wired/plumbed together. 6. Damper assemblies that ship in multiple sections shall be fastened together using 1/4"diameter steel bolts,lockwashers,and nuts.Fasteners shall be an 6" maximum centers on both faces of the frame. Combination Fire/Smoke Dampers(Modulating) 1. Multiple panel modulating damper assemblies will ship from the factory as a complete unit and must be ordered with sleeves. 2. Multiple panel high modulating damper assemblies are both electrically and mechanically linked between top and bottom sections at the factory. Fire Damper 1. Damper assemblies ordered without factory mounted sleeves are limited in size,so that the entire assembly ships as a single section. 2. Multiple panel high damper assemblies are not mechanically linked between top and bottom panels. 3. Multiple panel wide damper assemblies are not mechanically linked between panels. 4. Damper assembly sections that are not mechanically linked each have their own heat response device,such that they operate independently. 5. Damper assemblies that ship in multiple sections shall be fastened together using 1/4"diameter steel bolts,lockwashers,and nuts.Fasteners shall be on 6" maximum centers on both faces of the frame. ELECTRIC WIRING SCHEMATICS Notes 1. All wiring to be in accordance with N.E.C.(NFPA 70). 2. Refer to actuator label for appropriate voltage. 3. Connect incoming ground to the actuator assembly. 4. If the actuator remains electrically energized,yet the damper remains in the closed position,check to ensure that the reset button on the heat response device is depressed. Electric Heat Reponse Device(EHRD) Electric/Pneumatic Sensotherm(ESOT I PSOT) Temp. /�'� f High Disc 9 Low Temp. e e y Temp. Disc � r Disc Motor ? Motor " Motor or \/ Motor or � + E.P. Valve ^valve 3 d m � O r — I-111 Smoke Defector = Smoke _ Detector NC Damper Re-Open Damper 0 e Close SPDT See Actuator for Center Appropriate Voltage L1 (Hot) Customer Wiring L2(Neutral) See Actuator for g Appropriate Voltage L1(Hot) Customer Wiring L2(Neutral) L *�,,NLouver C FAMISIC„INC• i7eN '" air bcllance fai • �11RDR1E 450 Riverside Rd•Wyalusing PA, 18853•Phone 570-746-1888•Fax 570-746-9286 MCDLG-24-02-02 March 2019 INSTALLATION INSTRUCTION II-FS-19.03 Page 6 ELECTRIC WIRING SCHEMATICS ESOT/PSOT Wirina.Test.and Operating Instructions Damper is supplied with one low temperature thermal disc and one high temperature thermal disc.All dampers require a control switch(supplied by others)for re-openable operation. Customer Wiring 1. Connect input power lead L1 from the normal dosed position lead of the Master Control Switch(MCS)(or Remote Test Box,refer to SD-TEST) to damper lead L1. Note: If a smoke damper or other sensing device is to be employed,its NC contact set should be wired in sieries between the MCS position switch normal wire and lead L1. 2. Connect incoming lead L2 to damper lead L2. 3. Connect the reopen switch lead from MCS to orange damper lead. 4. Connect the incoming ground lead to the wiring enclosure. 5. If used,install position indication switch(refer to SD-SWITCH)per the schematic. 6. Replace enclosure cover. Circuit Test 1. Place Master Control Switch in damper close position. 2. Apply power. Result:The closed indicator light(if used)should be on and the damper blades closed. 3. Transfer the MCS switch to damper re-open position. Result:The damper blades should open;the closed indicator light(if used)should go off and the open indicator light(if used)should go on. 4. Transfer the MCS switch to the normal position. Result:The damper blades should remain open and the open indcator light(if used)should remain on. 5. Transfer the MCS switch to the closed position. Result:The damper blades should close;the open indicator light(if used)should go off and the closed indicator light(if used)should go on. emergency Oceration(Smoke Management) 1. MCS Closed Position:Damper will close regardless of whether the thermal switch device has activated or not and regardless of the command for the smoke system. 2. MCS Re-Open Position: If the damper has not been exposed to an elevated temperature higher than its rating,the damper will open.Also, the damper will open regardless of whether the low temperature disc(165°F or 212°F)has activated or not and regardless of a command from additional sensing devices,such as a smoke detector. 3. Refer to SI-SDET for more information on smoke detectors. Note: If the Master Control Switch(MCS)is in the re-open position and the high temperature thermal disc has not been tripped,the damper will remain open regardless of whether the low temperature disc and/or other sensing devices have tripped or not. If the damper has been exposed to an elevated temperature higher than its temperature degradation rating,or if the electrical or pneumatic supply has been disconnected,the damper will closed and remain closed regardless of any MCS position. MODULATING ACTUATOR WIRING INSTRUCTIONS Black 0 Belimo FSAFB24-SR Red O Modulating Actuator . 0 White Secondary Actuator Common Customer O 24 VAC Supplied 24 VAC Transformer 230 VAC &Wired Positioner 0 Black I Belimo O FSAFB24-SR Red Modulating Actuator - • O White c Notes: Secondary Actuator _ 1. Refer to the actuator manufacturer's installation instructions for full details. N U 2 Due to the required back-winding of the knee-lock,the actuator and blade rotation are not a 11 ratio.The actuator will rotate ® approximately 15°before the blades will begin to move. 3. Actuator Leads:Black is Common,Red is 24 VAC hot,White is 2- Black 10 VAC input. Belimo 0 ( FSAFB24-SR Red 0 ( 4. HRD=Factory mounted heat response device. Modulating Actuator O 5. Factory supplied transformer mounted inside steel enclosure with Primary Actuator knockouts.Enclosure is factory mounted to damper sleeve in near proximity to primary actuator.Transformer to be field wired to customer supplied positioner. 6 Secondary actuator(s)are factory wired to primary actuator. 41\ INC. 7. Signal change must be at least 0.15V and actuator should be drive to �,e Commercial Damper & mmer 2V or less once a day to ensure synchronization. Group w air balance 'n In the interest of product development,Mestek CDLG reserves the right to make changes without notice. INDUSTRIES L/ 450 Riverside Rd•Wyalusing PA, 18853•Phone 570-746-1888•Fax 570-746-9286 MCDLG-24-02-02 March 2019 INSTALLATION INSTRUCTION II-FS-19.03 FRAMING DETAILS (METAL OR WOOD, 1 HOUR OR 2 HOUR RATED BARRIERS) Page 7 Ceiling Runner Section A-A 24" .12" I Max MaxMi .2'14"Runner �II_11l2 i i Runner 90° Local Codes Bend May Require Double Headers A 1111 2 Fasteners Min.2YA'Stud IONii!_I_I_I_1_ Panhead Screws(Metal Studs) Nails(Wood Studs) 2 Fasteners IMI I 4 Per 90°Bend Floor Runner Section B-B (1 Hour Rated Fire Barrier) NOTES: Min. Y"Thick Min.2%"Stud or Gypsum Wallboard 1. These illustrated partition designs have Runner successfully been tested in conjunction IT • Drywall Screws(Metal Studs) with 1'14 hour classified fire dampers,for 41 IER Drywall Screws or Nails(Wood Studs) additional designs,reference Underwriters / Laboratories, Inc.Fire Resistance Directory. j a �/ Retaining AngleS pecific framing requirements of openings Min. 1"Overla / (May Be Reversed,Providing Adequatep may vary with the Local Authority that has /�������`�� Clearance is Maintained) =a•--- jurisdiction.Specific framing requirements should be provided in the architectural and 'See Note 2) structural drawings. 2. Reference the damper's installation Min. ''A"Thick Fire Damper Sleeve instructions regarding the approved method Filler Piece of attaching the damper to the sleeve, (See Note 4) attaching the retaining angles to the sleeve, required expansion clearances,sleeve Section B-B gauge,etc.Type of framing does not affect (2 Hour Rated Fire Barrier) the stated required expansion clearance. Min.'A"Thick 3. Gypsum panels surrounding the opening are Min.2'/:"Stud or Gypsum Wallboard to be fastened to all stud and runner flanges, Runner ,1001Drywall Screws(Metal Studs) 12"O.C.maximum. ���/\ Retains Screws or Nails(Wood Studs) /, 4. When wooden studs are used,filler pieces I ,� 0 Retaining Angle must be installed around the entire opening. Min. 1"Overlap ���_/'i (May Be Reversed, Providing Adequate Filler pieces are optional when metal studs 1►mmok.. ., Clearance is Maintained) are used(consult local codes to determine if filler pieces are required).Filler pieces are -See Note 2) to be double screwed(or nailed to wooden studs)on 12"max.centers to the web of Min.'A"Thick Fire Damper Sleeve runners and studs. Filler Piece 5. Double jamb studding shown and required (See Note 4) when opening width or length exceeds 36".Single jamb studding acceptable for .�iie.�li�U(�a openings 36"W x 36"H and smaller. mmerGrc1iaroupmP . 0 Z rN"" air balance ID" 1°� r 450 Riverside Rd•Wyalusing PA,18853•Phone 570-746-1888•Fax 570-746-9286 MCDLG-24-02-02 April2020 TAG: FSD-2 II-FAGM-20.04 Standard Installation Fire and Combination Fire/Smoke Rated Front Access (Grille Mount) Dampers Page 1 APPLICATION This UL Classified(see complete marking on product)multi-blade fire dampers and combination fire/smoke dampers have been tested with the damper out of the plane of the fire barrier.This arrangement allows for grille and grille/OBD assemblies to be flush mounted to the face of the fire barrier. Upon removal of the grille,the damper, damper actuator, and resetting of the heat responsive device are accessible. This damper is intended to close automatically when sensing elevated temperature or upon loss of electrical power. If closed due to loss of electrical power,the damper will reopen when electrical power is restored. • 1'IA Hour Fire Rated, UL File R4708 • For Use in Dynamic or Static Systems • Available in UL Leakage Class I or II (Combination Fire/Smoke Models) • Factory Mounted Sleeve and Actuator • 15 Second (maximum)Opening Time,Actuator Regulated Closure PANEL SIZE LIMITATIONS Actuation Electric Orientation Horizontal 250°or 350° Vertical 250°or 350° Assembly Min.Panel Max. Panel Min.Panel Max. Panel FS1,AS1, 16"W x 10"H 36"W x 42"H 16"W x 10"H 36"W x 42"H CG1,MS1 F52,A52, 10"W x 10"H 36"W x 42"H 10"W x 10"H 36"W x 42"H CG2,MS2 FA1, UA1, 10"W x 8"H 32"W x 42"H 10"W x 8"H 32"W x 42"H 0 CA1,MA1 FA2,UA2, 10"W x 8"H 32"W x 42"H 10"W x 8"H 32"W x 42"H CA2,MA2 Actuation Non-Motorized Orientation Horizontal 250°or 350° Vertical 250°or 350° Assembly Min.Panel Max. Panel Min. Panel Max.Panel 6 MD19, 15MD, a 17MD,MD17 10"W x 10"H 36"W x 42"H 10"W x 10"H 36"W x 42"H o MA19, 15MA, 10"W x 10"H 32"W x 42"H 10"W x 10"H 32"W x 42"H 2 17MA,MA17 AFC air b+lonc@ /�„s 111 450 Riverside Rd•Wyalusing PA, 18853•Phone 570-746-1888•Fax 570-746-9286 fd�m� LJ MCDLG-24-02-05 April 2020 I I-FAGM-20.04 Standard Installation Fire and Combination Fire/Smoke Rated Front Access (Grille Mount) Dampers Page 2 Installation Instructions This damper is approved for vertical and horizontal installation.This damper can also be mounted into wood stud construction walls,See Figure 3. Blades must run horizontal when vertically mounted.When vertically mounted,this damper is required to be insulated on the top and two sides(the bottom is not insulated).This damper cannot be mounted up-side-down,reference"Top of Damper"label.When horizontally mounted,the damper must be mounted in a masonry/concrete floor,See Figure 5.The exterior of the sleeve is insulated on all four sides.Pinching,racking and other causes of frame distortion can result in reduced leakage resistance of incomplete closure. Electrical wiring is to be in compliance with local codes and the National Electrical Code(NEC). Reference wiring diagram on damper,ensure that supply voltage matches actuator requirements. Damper and actuator must be tested prior to system start-up to ensure proper operation. 1. If the actuator is electrically energized yet the damper remains in the closed position,check that the reset button on the heat response device is depressed(disconnect power before resetting). 2. Insulation-The exterior of the damper sleeve is factory insulated.Care should be taken during installation to prevent ripping or other damage to the insulation. 3. Opening Size-No expansion clearance is required but sufficient clearance between the damper and the opening is required for the insulation and for mounting.The minimum opening width shall be%"larger than the nominal width.The minimum opening height shall be'/"larger than the nominal height when vertically mounted.When horizontally mounted,the opening height shall be' "larger that the nominal height.The maximum opening size shall be no more than''/"greater than the minimum opening size.Mounting-The damper is retained in the opening by the front sleeve flange and rear retaining angles.Rear perimeter retaining angles to be a minimum size of 11/2"x 1%"x 16 GA.steel or Mestek CDLG supplied 1%"x/"x 16 GA.steel"Tab-Lock"retaining angles.Angles are attached to the damper sleeve using#10 steel sheet metal screws or 3/is"steel rivets on 6"maximum centers. Example:An 18"W x 24"H nominal size damper,when mounted vertically,will require a minimum opening width of 18%"and a minimum opening height of 24'/.". Note the preceding example is based on the standard 20 GA.sleeve. 4. Duct Mounting-When duct work is connected to the non-flanged end of the damper sleeve,the following applies:Sleeves shall be steel of the same gauge or heavier as the duct to which it is attached.Sleeve gauge to be 20 GA.minimum, 14 GA.maximum.Connecting ducts shall not be continuous,but terminate at damper sleeve.Duct connections to the sleeve will be either of the breakaway or rigid types.The following determines if the connections are rigid or breakaway: For rigid type duct connections,sleeve shall be a minimum of 16-GA on dampers not exceeding 24"H and 14 GA.on larger units.The standard factory supplied sleeve is 20-GA galvanized steel and requires that a breakaway type duct connection will be employed.The following breakaway duct-to-sleeve connections may be used: Plain"S"Slip,Double"S"Slip,Inside Slip, Hemmed"S"Slip,Standing"S"Slip(Bar or Angle Reinforced),Standing"S"Slip(Alternate Bar).Various flanged connection systems are also approved as breakaway connections.Consult manufacturer's instructions for specific details. 5. Sensotherm Reopenable Feature-This feature allows the damper to be reopened from a remote switch(by others)after the low temperature heat responsive device has been activated.Electric sensotherm package is referred to as ESOT;pneumatic sensotherm is known as PSOT. 17"Deep when 3'% Grille Clearance A.Master Control Switch in closed position-the damper will close regardless 0.20"Thick 15"Deep when VA" of whether the thermal switch device has Insulation Grille Clearance 1" activated or not and regardless of the '/" command from the smoke detector. Integral Sleeve J """" and"/,s'Flange B.Master Control Switch in reopen (Open Corner) position-if the damper has not been exposed to an elevated temperature higher than its rating,the damper Of will open.Also,the damper will open regardless of whether the low limit switch (either 165°F or 212°F)has actuated or Heat not. If the damper has been exposed to Reponse an elevated temperature higher than its Device P 9 fp&W Inside Sleeve temperature degradation rating or if the • Nominal Width or electrical or pneumatic supply has been Height Minus Y" disconnected,the damper will close and remain closed regardless of a Master Control Switch position. 6. Maintenance-Damper shall be • maintained in intervals as stated in NFPA 80,90A and 92A unless local codes t`` u require more frequent inspections. Grille Clearance of 1''"or 31/4" /L �IIKa 14 GA. (Min) Commercial Dam 14 GA.(Max) Figure 1 '' 8 Louver Group Sleeve uw¢000w air balance ' In the interest of product development,Mestek CDLG reserves the right to make changes without notice. LJ 450 Riverside Rd•Wyalusing PA, 18853•Phone 570-746-1888•Fax 570-746-9286 MCDLG-24-02-05 April 2020 I I-FAGM-20.04 Standard Installation Fire and Combination Fire/Smoke Rated Front Access (Grille Mount) Dampers Page 3 Metal Stud or Masonry Wall Construction In addition to the previously stated General Requirements,the following instructions pertain to block,masonry or metal stud construction.See Figure 2 and Figure 5. 7. Grille-A minimum 26-GA steel frame is required,core of grille can be aluminum or nonmetallic. If a thinner or non-steel grille frame is used the open corners of flanged sleeve must be closed off with 20-GA minimum corner tabs(by others)riveted to flanges.When the flanges are not continuous but formed by a series of flange clips,grille flange must be steel of a minimum thickness of 26-GA.See Figure 4. 8. Mounting Damper to Opening-Unlike traditional fire damper installations,this damper requires no perimeter retaining angles.To mount the damper,insert the damper into the opening until the flange contacts the wall face,See Note 3 for proper opening sizing.Through the grille clearance area of the sleeve,secure the damper to the steel wall stud framing using#10 steel S.M.S. 12"O.C.(maximum),6'(maximum) from each corner,minimum of one fastener per each side,bottom and top.For masonry construction,use#10 x 11/4(minimum)steel concrete screws or anchors(same spacing as for steel stud construction).Follow masonry anchor manufacturer's recommendations for minimum distance from edge. Wood Stud Wall Construction In addition to the previously stated General Requirements,the following instructions pertain to wood stud construction walls.See Figure 3. 9. Grille-A minimum 26 GA.steel frame is required,core of grille can be aluminum or nonmetallic. If a thinner or non-steel grille frame is used, then open the corners of flanged sleeve must be closed off with 20 GA.(minimum)corner tabs(by others)riveted to flanges.Grille is attached to either the sleeve flange or to the wood framing with steel screws 10"maximum on center. 10. Mounting-The damper is retained in the opening by the front sleeve flange and rear retaining angles. Rear perimeter retaining angles to be a minimum size of 1'h"x 1'//•x 16 GA.steel or Mestek CDLG supplied 1%d'x'a"x 16 GA. steel"Tab-Lock"retaining angles.Angles are attached to the damper sleeve using#10 steel sheet metal screws of 3/,E"steel rivets on 6"maximum centers. `^� I— 4'h" —I Mounting Damper (typ.) to Opening If Duct (See Note 10) —4Y, Insulation Connection 1 Metal Framed (yp.) / (See2) (See Note t Note 4) i Insulation If Duct Masonry (See Note 2) connection or all -�- a. j� (See Note 4) r Mounting-'777 Daampermper to -1 ❑ L Opening (See Note 8) 0 0 ik rt ❑ t e il o Ari• „,..ii.,„.„, , 7 , ..a,„. . 7- vs..., I lk El 11 T ` f Grille J Opening Size (See Note 7) (See Note 3) Opening Size 5,�„ i 5Y„ (max.) I (max.) (See Note 3) Figure 2 Figure 3 Metal Stud(Shown)or Masonry Wall Grille �A���7t���(y�t (See Note 9) Wood Stud Wall `` Commercial D JNC. v '� &Louver Group icair balance aim 0 115MM _� _ 450 Riverside Rd•Wyalusing PA, 18853•Phone 570-746-1888•Fax 570-746-9286 MCDLG-24-02-05 April 2020 I I-FAGM-20.04 Standard Installation Fire and Combination Fire/Smoke Rated Front Access (Grille Mount) Dampers Page 4 "/,."x"/,e'x 3"x 20 GA.Steel Angles, Minimum 1 per Side of Damper(4 Wlrina Schematic Minimum),Angles Attached to Sleeve / with Two'/,e"Rivets a _ 12_ 1._ 1 Max. Motor Motor m � /J (I:S''''\ Damper Sleeve, m No Flange ° w a Minimum 26 GA.Steel > 3 a Grille Flange,Field Attached to"/,e"x'%e"x 3" Steel Angles Fiaure 4 Smoke NC Detector - / i? See Actuator for— r y Un-Flanged Sleeve.Damoer Above Floor Proper Voltage PIaR€ L1 L2 Fire or Fire/Smok- — r Customer Wiring Damper r. Ojai — For use on dampers with one heat response device(non-reopenable). . Opening Size 8"Max. (See Note 3) 4. Low High I,r: Temp6 Is). Temp. Factory See • Disc Disc Insulated Note 90 4° a Sleeve,4 sides t0 ? t>: otor otor or E.P. or E.P. _ Masonry . (similar) -. . .a . ? Valve Valve T Floor °. '' ; Masonry - Floor 03 Fastener : v.•. . p' m rn a a (See Note 8) ? . . . 0 co 4 ! 0. m (5- 1., t•t. Opening Size Flanged Sleeve 8"Max. ' (See Note 3) See Note 7 for j Proper Closing of T a Flanged Sleeve Smoke 1 Corner Detector Single Thickness or Airfoil Fire or Fire! immiir Smoke Damper NC r Norm I�a ' Spa Reopen ? CTR rrre Off See Actuator for Flanged Sleeve.Damper$ Switch Proper Voltage Below Floor Plane ,.....'il L1 Customer Wiring L2 If Duct Connection, See Note 4 For use on dampers with two heat response device(ESOT or PSOT). Figure 5 lifISTEKINC. Concrete or Masonry Floor/Ceiling Commercial Damper &Louver Group /l"�"'r air balance { . ID In the interest of product development,Mestek CDLG reserves the right to make changes without notice. ecwreO T r='ri 450 Riverside Rd•Wyalusing PA, 18853•Phone 570-746-1888•Fax 570-746-9286 1 MCDLG-24-02-05 SIEMENS Technical Instructions Document No. A6V11275901 April 10, 2018 OpenAirTM GJD Series Electronic Damper Actuator UL Listed Fire/Smoke and Smoke Control Dampers 2-Position, 30-second Run Time, 15-second Spring Return Time N., ,eT C ® US & a . 8 LISTED IOW Description The OpenAir direct coupled,fast-acting, two-position, spring return electronic actuators are available as 24 Vac/dc, 120 Vac, and 230 Vac models. They are intended for use on UL-listed smoke control dampers and combination fire/smoke rated dampers. Features • (Optional) Built-in auxiliary switches: Fixed switch points at 5° and 85° rotation. • Electronic Fusible Link(EFL) capability with three temperature ratings: 165°F (74°C), 212°F (100°C), and 250°F (121°C). • Reversible fail-safe spring return. • Plenum-rated plastic housing. • Pre-cabled lead wires. • 30-second drive/15-second return operation at rated torque, temperature and voltage. Application This actuator is used for the control of dampers requiring up to 20 lb-in (2 Nm)driving torque. It is intended for control of UL-listed smoke control dampers and combination fire/smoke HVAC dampers. This actuator is designed to meet the 2002 revisions to the UL 555/555S and the AMCA Standard 520 specifications. Product Numbers Torque Voltage Control L Signal .a, 2 Product CV U c 0 7 y Number* ° o. c E 3 A m a .) m m a E 9 N G ar LL O.C A 7 N Z N -. N N W M U Q GJD121.1U • • — — • • • — GJD126.1U • • — — • • • • GJD221.1U • — • — • • • — GJD226.1U • — • — • • • • GJD321.1U • — — • • • • GJD326.1U • — — • • • • • Siemens Industry, Inc. Page 1 Technical Instructions OpenAir GJD Series Electronic Damper Actuator UL Listed Fire/Smoke Control Dampers Document No. A6V11275901 April 10, 2018 Warning/Caution Notations WARNING A Personal injury or loss of life may occur if you do not perform a procedure as specified. CAUTION: Equipment damage may occur if you do not perform a procedure as specified. Service A WARNING: Do not open the actuator. Personal injury may occur if opened. Opening the actuator voids the warranty. If the actuator is inoperative, replace the unit. Specifications Operating voltage 24 Vac±20% 24 Vdc+20%,-10% Power supply Frequency 50/60 Hz 120 Vac±10% Frequency 60 Hz 230 Vac±10% Frequency 50/60 Hz Power consumption 24 Vac/dc, 120 Vac Running - 10 VA/5W Holding -5 VA/3W Power Consumption 230 Vac Running - 12 VA/5W Holding - 7 VA/3W ACAUTION: Continuous use at voltages above the recommended tolerances may damage the actuator. Function Running torque 20 lb-in (2 Nm)(minimum) Stall torque(minimum) 35 lb-in (4 Nm) Torque reduction at elevated temperature Less than 10% Runtime for 90° 30 seconds nominal closing(on power loss)with spring return 15 seconds maximum Nominal angle of rotation 95° Life Expectancy Minimum 20,000 full stroke cycles Mounting Damper shaft size 0.5-inch (12,7 mm)round Damper shaft length, minimum 1.4-inch (36 mm) Housing Enclosure NEMA 1 Material Plenum-rated plastic Ambient conditions Operation 0°F to 130°F(-18°C to 55°C), one time 250°F(121°C)'/:hour per UL555S Storage and transport -40°F to 158°F (-40°C to 70°C) Ambient humidity(non-condensing) Maximum 95% rh non-condensing Teflon@ cable 400°F(200°C) Page 2 Siemens Industry, Inc. OpenAir GJD Series Electronic Damper Actuator UL Listed Fire/Smoke Control Dampers Technical Instructions Document No. A6V11275901 April 10,2018 Specifications, Continued Fixed Dual End Switches Fixed Dual End Switches AC rating 24 Vac to 250 Vac, 24 Vdc 6A resistive/ 2 FLA/12 LRA Temperature rating 350°F(177°C) Agency certification UL60730 cUL CSA 60730 CE conformity for Residential, Commercial, and Industrial environments Australian RCM conformity Miscellaneous Pre-cabled connection Length: 3 ft(0.9m) 19/30 strand 18 GA Dimensions 5.61" H x 2.83"W x 2.48" D (142.6 mm H x72 mm W x 63 mm D) Weight 1.32 lbs. (0.60 kg) Country of Origin USA Accessories Electronic Fusible Link (EFL) ASK791.165 (165°F [74°C] operation) ASK791.212 (212°F [100°C] operation) .t I_ ASK791.250 (250°F [121°C] operation) it Figure 1. Operation When power is applied, the actuator coupling moves toward the open position, 90°. The actuator opens in 30 seconds nominal, 90° at 60 Hz. In the event of a power failure or when operating voltage is turned off, the actuator returns to the 0 position. The return time is 15 seconds (maximum)for 90°. The National Fire Protection Association NFPA 92A Standard for Recommended Practice for Smoke-Control System and UL 864 Standard for Control Units and Accessories for Fire Alarm Systems, require weekly self-tests for dedicated smoke control equipment used in a smoke control system. The National Fire Protection Association NFPA 72 Standard for National Fire Alarm Codes states that all life-safety systems are to be functionally checked at least annually. The GJD actuator does not require any periodic cycling to function properly as an integral part of an active smoke control damper system. Check the smoke control damper/actuator every time you functionally check your smoke detectors, emergency lights, and/or power generators for operation. Siemens Industry, Inc. Page 3 Technical Instructions OpenAir GJD Series Electronic Damper Actuator UL Listed Fire/Smoke Control Dampers Document No.A6V11275901 April 10, 2018 Installation See OpenAirTM GJD Series Electronic Damper Actuator Designed for UL Listed Fire/Smoke and Smoke Control Dampers installation Instructions (A6V11275436)for detailed guidelines. ACAUTION: Read and carefully follow the Installation Instructions to avoid equipment damage. Wiring All wiring must conform to NEC and local codes and regulations. Wire Designations RED Function Color (SUPPLY) Supply Red 24 Vac/dc CJ Neutral Black i BLACK (NEUTRAL) Figure 2. ?I AC4,Ln-i ♦ Function Color Line Black 120 Vac 0 Neutral White • MIRE NMI Figure 3. BROWN IL.lei Function Color ♦ Line Brown - r Neutral Blue 230 Vac BLUE (Neutral) Figure 4. Page 4 Siemens Industry, Inc. OpenAir GJD Series Electronic Damper Actuator UL Listed Fire/Smoke Control Dampers Technical Instructions Document No.A6V11275901 April 10,2018 Auxiliary Switches ST-85' 85"-90" DUAL AUXILIARY DUAL AUXILIARY DUAL AUXILIARY SWITCHES SWITCHES SWITCHES Actuator Switch A Switch B COMMON COMMON COMMON COMMON COMMON COMMON Position Common S1 Common S4 5/ S4 51 54 51 S4 Connected to Connected SWITCHI SWITCHI II SWITCHI SWIT:H, , SWITCHH.. SWIRL/H♦I to il q B 4 y g I 'Y- 9-/-S 0° to 5° S3 S6 $2 53 56 56 52 53 55 SO 52 53 55 56 5° to 85° S2 S6 NO. NC. NO. N.C. 85° to 90° S2 S5 A CAUTION: Mixed switch operation to the switching outputs of both dual end switches (5° and 85°) is not permitted. Either AC line voltage from the same phase must be applied to all six outputs of the fixed dual end switches, or UL-Class 2 voltage must be applied to all six outputs. ems 1 I 1 Figure 5. GJD Actuator and EFL. NOTE: GJD Damper Actuators are pre-wired for coupling with an EFL sensor. Siemens Industry, Inc. Page 5 • Technical Instructions OpenAir GJD Series Electronic Damper Actuator UL Listed Fire/Smoke Control Dampers Document No. A6V11275901 April 10, 2018 Dimensions 2.83(72) 2.46(62.51 2.83(72) �— _ - . • —1 1 A r' �B/� 6 I a L1111111j - I � °i , e t o tom =V� 9 41 L 0.08 (21 0.39 -r it 1 (10) T h —_--6.61.__._..._... 0.47 w. (168 _._..._. 4036 0.79 Mil .' (6) , (201 iV-o c, e 0 -<, Q o '`0 0 o e 0 7.09 (180) Figure 6. Dimensions of OpenAir GJD Actuator in Inches (Millimeters). Information in this publication is based on current specifications.The company reserves the right to make changes in specifications and models as design improvements are introduced.OpenAir is a trademark of Siemens Schweiz AG. Product or company names mentioned herein may be the trademarks of their respective owners.©2018 Siemens Industry, Inc. Siemens Industry,Inc. Your feedback is important to us. If you have comments Document No.A6V11275901 Building Technologies Division about this document,please send them to Printed in the USA 1000 Deerfield Parkway sbt_technical.editor@siemens.com Page 6 Buffalo Grove,IL 60089 USA +1 847-215-1000 RECEIVED J U N 2 0 2023 CITY OF TIGARD BUILDING DIVISION DARTMOUTH CROSSING HVAC EQUIPMENT 6835 SW CLINTON ST. TIGARD, OR 97123 STRUCTURAL CALCULATIONS & DETAILS MASON EO# 36858 June 14, 2023 ��RED PROFESS/0 <S\� G1NF v -J965 ri„OREGON FkAN L AO' EXPIRES 12.31.24 Prepared By MASON INDUSTRIES, Inc. 1.; •4, '■ MANUFACTURERS OF VIBRATION CONTROL PRODUCTS 350 Rabro Drive 2101 W.Crescent St.,Suite D Hauppauge,NY 11786 Anaheim.CA 92801 631f348-0282 714/535-2727 :� FAX 631,348.0279 FAX 714,r5355738 Info@Masonand,00m www,Mason•Ind.com ° MASON INDUSTRIES, Inc. 14a.NL+=ACTURERS OF VIBRATION CONTROL PRODUCTS PROJECT CERTIFICATION 1 e 350 22Dro Dyke 2101 W.Crescent Si..Suite I) ., . Hauppauge,NY 11768 Anaheim,CA 92601 631348-0252 714,535-2727 DATA & TABLE OF CONTENTS "" FAX 631,346.02279 FAX 714,535-5738 Info@Masonand,com aww,Mason•Ind.com PROJECT DATA: PROJECT NAME: DARTMOUTH CROSSING MASON E.O. NUMBER: 36858 PROJECT LOCATION: 6835 SW CLINTON ST. TIGARD, OR 97123 CUSTOMER: MASON OREGON ��pED PROFESS t.Y (NGI NFF �OZ GOVERNING BUILDING CODE: OSSC 2019 V9965 r- SEISMIC DESIGN CATEGORY: D j k_ OREGON Sds: 0.695 c9��gr10,Z61c Ip: 1.0 Ski% LAND\— r EXPIRES 12.31.24 TABLE OF CONTENTS: EQUIPMENT TAGS: REF. REF. CALC FCUs Al - A4 T1 - T2 Notes: 1.Certification is for Mason product selections and/or equipment anchorage only. No other responsibilty is taken or implied. 2.Verification of building structural elements supporting the above equipment is beyond the scope of this certification. 3. Construction or fabrication should not begin until all approvals are in place, including approval of this submittal by owner's agents,consultants, and/or by building permit plan check. Mason Industries, Inc.will not assume responsibility for construction done prior to the aforementioned approvals. DATE: 6/14/2023 CERTIFIED FOR TYPE MASON INDUSTRIES, Inc. JOB NAME DARTMOUTH CROSSING SSBS ^B ^ Manufacturers of Vibration Control Products CUSTOMER: MASON OREGON J J J iI. 350 Rabro Drive 2101 W. Crescent St., Suite D Hauppauge, NY 11788 Anaheim, CA 92801 CUSTOMER P.O.: JOB NO.: 631/348-0282 714/535-2727 I' __i FAX 631/348-0279 FAX 714/535-5738 MASON E.O.: 36858 DWG.NO.: WF-36858-01 SEISMIC SOLID REQUIRED: (6 ) TAG: FCUs BRACING ASSEMBLY (12)12d(3-1/4") COMMON (1)1/2"O STEEL BOLT 5 NAILS ASTM A-307 MIN. 11�4 CLINCH AT per bracing locations L3x34/4,5"LG. JOIST WEB .0a. ' �1 -- ° 0 -- - - - 15°-45° 1 L // I \ 4 UCC;REF.XSC PLATE @ 28"MAX.SPACING WASHER I It SSBS-12 03/8"THREADED ROD REF.X4 MIN. -ROD STIFFENING 1 5/8"x 12ga STRUT ' STRUT 9'-6"MAX.LENGTH \ I IF ROD EXCEEDS 18" 1 EQUIPMENT �.. SHB-3/8 REF.WF-SHB ELEVATION VIEW 5" 11/4" 21�2" ix- TAG: QTY. DAIKIN WT(LBS) FCU-2,3,6 (3) FBQ18 80 FCU-1 (1) FBO24 80 1n FCU-5 (1) FBQ36 102 FCU-4 (1) FBO48 102 2x(MIN.SPECIFIC GRAVITY G=.50) (2)Y2"0 ASTM A307 BOLT OR ASTM A36 THREADED ROD, �� WITH 2x24Y4 WASHER OF BACK SIDE OF 2x L3x3x�4,5"LG. i1 L _ 2" ;mime ALTERNATE MIN. I v ' CABLE DIRECTIONS I \; (lop unit bracing) `Ii �[° •>t III[>t El WOOD BLOCKING TO BE DESIGNED BY STRUCTURAL ENGINEER ZONN .I.X.7 IINT1 1:1 • A II N TOP VIEW M r y DWN CHKD DATE DWG.NO. TA TH 06/13/23 WF-36858-01 A MASON INDUSTRIES, Inc. JOB NAME DARTMOUTH CROSSING FM Approved Mnufacturers 3 0aRabro Drive of V12101oW.Crescent Ave.,Suite D CUSTOMER MASON OREGON SSBS Hauppauge,NY 11788 Anaheim,CA 92801 CUSTOMER P.O. J 631/348-0282 714/535-2727 E.O.36858 X4 Seismic Solid FAX 631/348-0279 FAX 714/535-5738 MASON M.I. DWG.NO. ili Brace Strut "'=" nto@Mason-Ind.com NO.REO'D. TAB Anchor r```- ```1 www.Mason-Ind.com _ 11> Solid Brace Anchor (Formed Steel) APPROVED Finish: 1/2"(13mm)Dia. Bolts 2"(51mm) All parts are Zinc asit(1)Required per SSBS 1 1/4"(32mm) Electroplated. s illustrated. Torque Bolts to 50 ft-lbs(68 Nm). (By Others) / 17/32"(14mm) 2 1/4" Hole Dia. * (57mm) \ b 9 \ "A"Hole Dia. -Av Strut shown, 1 7/8" Bolted too en 1 1 11/16" may be Steel Angle p y (48mm) drilled to suit. side or Strut Web mo (43mm) (By Others) ® 3 3/4' 1® Strut Attachment Nut with •�� (95mm) 31 6" Stamped Teeth `. p �49m� (By Others) ` \ 0001 �v. `Strut Attachment Nut must have stamped teeth to achieve these values. NOTE: Not to be used as a vertical hanger for Ratings are based on attachment to steel. equipment,ductwork or piping. Ratings may change depending on attachment methods to concrete. To be used as a seismic restraint only. Testing was done by FACTORY MUTUAL(FM Approvals). I Preferred Installation Angle is 45° Maximum Variation is±15° TYPE SSBS DIMENSIONS&RATINGS FM Certified Load Ratings* Size A Bolt Size Installed Angle 30°-44° Installed Angle 45°-59° (in) (mm) (in) (mm) lbs kN kg lbs kN kg SSBS-12 17/32 13 3/8 10 660 2.9 299 970 4.3 440 SSBS-12 17/32 13 1/2 13 660 2.9 299 970 4.3 440 SSBS-20 25/32 20 5/8 16 660 2.9 299 970 4.3 440 SSBS-20 25/32 20 3/4 19 660 2.9 299 970 4.3 440 SSBS-25 11/32 26 7/8 22 660 2.9 299 970 4.3 440 SSBS-25 11/32 26 1 25 660 2.9 299 970 4.3 440 Certification Form S-119 10/2013 FORM BY:R.R. DWN: TA CHKD: DATE: 06/13/23 DWG.No. X4 APPR BY:J.T. i :,54.1 :;..d MASON INDUSTRIES, Inc. JOB NAME DARTMOUTH CROSSING FM Approved AuF C 1_,...1 Manufacturers of Vibration Control Products CUSTOMER MASON OREGON S H B 350 Rabro Drive 2101 W.Crescent Ave.,Suite D �.......•C :: :::1 CUSTOMER P.O. Hauppauge,NY 11788 Anaheim,CA 92801 631/348-0282 714/535-2727 E.O. 6858 WF-SHB ' FAX 631/348-0279 FAX 714/535-5738 MASON M.I. DWG.NO. Seismic Hook inn InfocdMason-Ind.com NO.REQ'D. TAG Brace 1' www.Mason-Ind.com igi> 17/32"[14mm] [ 1 " Finish: Hole Dia. [43mm] *Strut Attachment Nut must have stamped teeth All parts are Zinc 16 to achieve these values.Ratings are based on Electroplated. c attachment to steel.Ratings may change depending APPROVED 1 7/8" (/� on attachment methods to concrete.Testing was [48mm] I I done by FACTORY MUTUAL(FM Approvals). Counterbored Nut / j.' 44,4 Restraint Hole i� 2 i 'P �`a/ NOTE: Not to be used as a vertical hanger for RD /� i 47 equipment,ductwork or piping. A\ v �� To be used as a seismic restraint only. i *NOTE:For loads upto 1500 lbs one Strut �� ��,I nut is required,above 1500 lbs two Strut \30 � �'�� Nuts are required. ��� W I A c. ' \ 1 Installation may include Mason SFB 1/2"(13mm)Dia.Bolts 1 O refer to S-127-1 or 2 Required per SHB Strut shown, ,4\ for details (By Others) may be Steel i. Torque Bolts to 50 ft-lbs Angle drilled a (68 Nm).See note bebw. to suit. � �'� 14 if' (By Others) \30 = O 1i Nut is locked in oto-'."'"°" � Q e my one Bolt / of Counterbore *V @ i y required at p �i Longitudinal Bracing , Max.Capacity N ® t Iv . 44 �9.' �l�® Strut Attachment e � (' Nut with Stamped Transverse and 1 � Teeth(By Others) Longitudinal Bracing 'N d, Transverse Bracing O TYPE SHB DIMENSIONS & RATINGS (RD)Rod Dia. W A FM Certified Load Ratings* Size 30°-44° 45°-59° (in) (mm) (in) (mm) (in) (mm) lbs kN kg lbs kN kg SHB-3/8 3/8 10 2 51 2 51 1420 6.3 644 1000 4.5 454 SHB-1/2 1/2 13 2 51 2 51 1710 7.6 775 1280 5.7 581 SHB-5/8 5/8 16 21/8 54 115/16 49 1520 6.8 690 1100 4.9 499 SHB-3/4 3/4 19 21/4 57 17/8 48 1660 7.4 753 1040 4.6 471 Certification Form S-126 10l2013 APPRBY.R.R. DWN: TA CHKD:_ DATE: 06/13/23 DWG. No. WF-SHB MASON INDUSTRIES, Inc. JOB NAMEDARTMOUTHCROSSING ��� Manufacturers of Vibration Control Products CUSTOMER MASON OREGON 350 Rabro Drive 2101 W.Crescent Ave.,Suite D Hauppauge,NY 11788 Anaheim,CA92801 CUSTOMER P.O. SEISMIC ROD 631/348-0282 714/535-2727 X5C CLAMPS FOR FAX 631/348-0279 FAX 714/535-5738 MASON M.I.e.o.36858 Info@Mason-Ind.com STRUT www.Mason-Ind.com DWG.NO. CHANNELS TYPE UCC WITH STEEL STRUT ASSEMBLY RATINGS THREADED ROD Maximum Strut Stiffener Maximum Rod Compressive Max UCC STRUT STIFFENER Size Force Minimum Size SpacingOlik g in(mm) lbs(kN) in(mm) in(mm) in(mm) /u C3/8 425 1 5/8 x 1 5/8 x 12 Gage 96 28 u (10) (1.9) (41 x 41 x 2.5) (2436) (711) u j 1275 1 5/8 x 1 5/8 x 12 Gage 96 38 j (13)2 11 (5.6) 1200 ) 1 5/8 x(411 5/8 x 25Gage (1208) (965)8 u % (5.3) (41 x 41 x 2.5) (3048) (965) u 1475 1 5/8 x 1 5/8 x 12 Gage 96 48 u 5/8 (6.5) (41 x 41 x 2.5) (2438) (1219) 11 u i (16) 1325 1 5/8 x 1 5/8 x 12 Gage 120 48 (5.9) (41 x 41 x 2.5) (3048) (1219) 3/4 2500 1 5/8 x 1 5/8 x 12 Gage 144 57 till i,�����1 (19) (11.1) (41 x 41 x 2.5) (3658) (1448) 01/2"-13U NC x 1-1/2"(38) LOCKING BOLT .. TORQUE TO 10 ft-Ibs(13.5 N-m) MI o_ rftrii 1(36" ki01--- (30) APPROVED Fixed Equipment Anchorage Office of Statewide Health Planning and Development 1-5/16" 1-1/4" OPA-0349 (33) (32) ::tea. on "' r January 16,2009 Anthony R.Pike (916)440-8470 Certification Form S-134 04f2014 IDWN: TA ICHKD: (DATE: 06/13/23 IDWG.No. X5C MASON INDUSTRIES, Inc. SEISMIC OVERTURNING CALCULATIONS Manufacturers of Vibration Control Products SEISMIC RESTRAINT: SSB(S) (SEISMIC SOLID BRACING) 350 Rabro Drive 2101 W. Crescent St., Suite 0 Hau831 ppau/348ge,—0282 NY 11788 Anoheim, CA 92801 714/535-2727 REFERENCE CODE(S): ASCE 7-16 FAX 631/348-0279 FAX 714/535-5738 DWG NO:WF-01a-CAL Equipment overturning calculations based on seismic load applied at a critical angle. As defined in ASCE 7, section 13.3.1, the seismic Horizontal force, Fpn, may be calculated using the following formula: 0.4aS nsWP Iz ph(calc) = / A 1+ 2— P \ Ip / Except that: Fph shall not be less than Fph)mIn) = 0.3SosIpWp and need not be more than Fph(max)= 1.6SosIpWp. Where: Wp = Component operating weight ap = Component Amplification Factor, refer to ASCE Table 13.6-1 Rp = Component Response Modification Factor, refer to ASCE Table 13.6-1 Sds= Design spectra response acceleration at short period, refer to ASCE section 11.4.4 Ip = Component Importance Factor, refer to ASCE section 13.1.3 z = Component Attachment Elevation with respect to grade. h = Structure Roof Elevation with respect to grade. Convert from Design Strength to Allowable Stress Design: Fph(a) = Fph*0.7 Fpv = 0.2*Sds*Wp*0.7 TENSION/COMPRESSION IN BRACE MEMBER: U F v 11 For worst loading condition, apply Fph along the sameh. p line as on brace member. .-. = Fph + F Fph (N12)*Cos0 N*Sin() A • N = number of brace arms ELEVATION If Tc < Tc(allow) O. K. I I F.h Reference AISC, 13th • 3 Edition, Chapter J3.6(ASD) ft= Tbolt =Vbolt PLAN VIEW At Ak Tallow= = F'nt2 Ab 3.' O* Fnt* V bolt fv � F'nt= 1.3*Fnt Fnv L Fnt 0 � Vallow= Rn = Fnv*Ab 2 T bolt Fnt& Fnv from table J3.2 Tc Ab = nominal unthreaded body area Check for: Tbolt L 1 00 & Vbolt L 1.00 Tallow Vallow DWN:TA CHKD: I DATE: 06/13/23 DWG NO:WF-01a-CAL MASON INDUSTRIES. Inc. SEISMIC OVERTURNING CALCULATIONS Manufacturers of Vibration Control Products JOB NAME: DARTMOUTH CROSSING 350 Ralnro Drive 2101 W.Crescent,Ste.D CUSTOMER: MASON OREGON Hauppauge,NY 11788 Anaheim,CA 92801 EO NUMBER 36858 631/348-0282 714/535-2727 FAX X714/535-5738 6/13/2023 WF-01 a-CAL Tag: FCUs Max.Weight,Wp= 102 ap= 2 1/2 Rp= 6 Sps= 0.695 Ip= 1.00 z= 1.00 h= 1.00 Fph 35 Fph(min.)= 21 Fph(,„„„)= 113 Fph(a)= 25 Fpv= 10 Seismic Force Ratio= 0.24 theta(deg)= 45 theta(rad)= 0.785398 #of Braces resisting Fph= 2 #of Braces resisting Fpv= 4 Tc= 21.05 Seismic Cable Brace= SSBS-12 Strut member Size= 1 5/8 x 12 Ga. Tc(allow)= 1250.00 Check Strut= O.K. Anchor Bolt Size= 1/2 Steel Bolt Quality= A307 Ab= 0.196 At= 0.142 Ak= 0.136 No. of bolts per brace= 1 Tbolt— 14.89 Vbolt= 14.89 ft= 104.84 fv= 109.46 T allow= 4418 V allow= 2356 Fnt= 45000 Fnv= 24000 F'nt= 45000 Tcheck= 0.00 Vcheck= 0.01 Manual of American Institute of Steel Construction,Allowable Stress Design, 13th Edition WF-01a-CAL TM ota.0 • AireSj ` re r n ENERGY ae �y38 nk, .�, �esM + A PRoDo° ,JUIY1 0 2023 biabl.'E.-.' fig? JI' r'Jd tJJIIJ5 filar?. C!'JIIJIJ.E r 6TI RD ;rr�I1 d SJJ� 1'�s'1 cJ1 J'I IIJJIJi- pil L" �rr� C'� ..°e _; 'li -:: Blend with any decor Whisper quiet operation Simple Installation • White grille and diffuser • Low sone blowers are 50% quieter • Install with hand tools in • No straight line sight or sound than other transfer fans standard 16" on center walls from room-to-room Room-to-Room Level-to-Level Models ASI or AS2 Model ASLL Transfer Air between floors, either up or down to help balance tem- Make rooms peratures or spread the warmth adjacent to from stoves and fireplaces. ductless heating ! cooling comfort- able, even with closed doors. ______________________ Save money by IIPIIIIII. eliminating the ---,`"...- need for added air handlers or . , heaters. ''.*.: . — — MO , — ] a .El ,.. — B :.".,..E., . Ceiling to Floor Floor to Ceiling Straight Through Lower to Upper Level Upper to Lower Level Accessories Switch-it Wireless Switch-it Wireless 24 Volt Fan Center A52 3-Speed Switch AS2 Transfer Fan Duct Kit Wall Switch Model Digital Thermostat Model FC24 Model AS2SW3 Model DK2 SWS (Heat Only) Model S WT Combines a 24 volt trans. For High,Med&Low control of For installation in obstructed wall cavities, Locate switch up to 80'from Mounts in receiving room to former with a 24 volt relay to model AS2 Transfer Fan. where metal studs with wiring knock outs receiver.Includes rocker activate fan.Can also switch fan on interface any 24 volt thermo- are used or to conform to energy codes switch,batteries,receiver manually.Includes thermostat, b. stat with an AireShare requiring metal ducts Installs through cut and mounting hardware. s batteries,receiver and mounting transfer tan.Use with models out needed for AS2 blower.Centerline Use with models AS1,AS2 hardware.80' i`:; AS1 and A52. of diffuser r &ABLE _ n 0 ° in target range Use . . �,; " r A 9 Ct with models — ' room is S" AS14AS2 x` above top of 11/4 &A511 4 . - :'� blower discharge""- Case History: AS1:Room-to- AireShareTM transfer fans enhance Room Cross- performance and comfort of split flow Fan, Hardwired iiiiiisystem air handlers Harbor View Windows, Heating and Air, Inc.,Brookings, Oregon,has installed ductless split system heating/cooling for years.Ductless sys- tems offer high-energy savings,but can also have comfort challenges if a an air handler is not installed in each room.On a recent multi-family project using ductless systems,Harbor View was able to overcome this AS2:Room-t, problem by installing an average of two AireShare transfer fans per five-room townhouse to effectively distribute conditioned air to rooms Room Du. inst without air handlers. Blowe 'ardwired nlet illtilli- .1-'-- ,,., 4 (wi for desired "We thought it might be a great solution to a long term problem...to .eed upon install) flip a switch and be able to draw air conditioned or heated air out of the main rooms into AireShare Air -- _ the small Transfer Fan Handler y rooms and s — . it's working 1111011016141 �— perfectly," ASLL:Lev- o- '.i f said Pat and Level Cr. s-flow --- . j Sherry Nied, Fan ardwired Harbor `11/i. , View's f owners. ` j Model Selection Advice: Since it is impractical to calculate heating and cooling loads for the variety of (AireShare CFM x 60)/(L x W x H of target room)=ACH geographic areas,construction methods and the temperature of transferred air we base our model selection advice on providing a minimum of 3 Air 3-4 Air Changes/hour(ACH)recommended for best temperature equalization. Changes/Hour(ACH)to the target room.Door under-cuts or pressure relief trans- 4-5 Air Changes/hour(ACH)recommended for rooms with high cooling or fer grilles in the target room are necessary for proper AireShare performance. heating loads. AS1 for rooms up to 150 Ft' Examples: Rooms with extensive outside walls,windows,over tuck under AS2 for rooms up to 275 Ft' garages or in extreme climates. More than one AireShare transfer fan can ASLL for rooms up to 175 Ft' be installed to reach desired number of air changes for large spaces. Dimensions and Specifications: Intake Grille Adjustable Sleeve Floor/Ceiling Grilles Dimensions Minimum A* B* for Model ASLL for Model ASLL Model A B C Wall Cavity Volts Watts CFM Speed Sones Sones A B C A B C 12 1/4" 8 3/4"to 16 1/2" 4 1/4" 13 3/4" 5 3/4" 1/4" ASLL 13 3/4" 5 3/4" 1/4" N/A 120 20 70 Fixed 1.2 1 _ _ *AS1 15 3/4" 7 3/4" 1/4" 3" 120 20 60 Fixed 1.2 1 I a,' 52 16" 10" 2 1/2" 4" 120 30 110 Hi 1.5 1 9 �� IK 21 95 Med 1 <1 ,..`,' , 16 80 Low 1. 1 1, A C A*Sones:Intake Room A B*Sones: Target Room �I C l Diffuser for Models Model AS1 Model AS2 rF-1 AS1 &AS2 Intake Grille Intake Grille p' B \ TIERNLUND 15 1/8" 3" 3 7/8"** B ( S G Lr` L B j Aire • hare o \ I Of _ - t Vans r Fans **Collapses for 2"x 3" \ I stud compatibility CI o --o . '!.!',e TJERNLUND PRODUCTS, INC. = :v' 1601 Ninth Street White Bear Lake, MN 55110-6794 13 • IR Phone:651.426.2993 800.255.4208 Fax:651.426.9547 For more information ®V Visit our web site:www.tjernlund.com Copyright©2019 Tjernlund Products,Inc. All rights reserved. P/N 8500730 Rev E