Report (163)
OFFICE CCPV cs� l�� t Sw 'FICE COPS" CROMWELL FIRE SYSTEMS 25599 SW 59TH AVENUE; WILSONVILLE, OREGON 97070 PHONE: (971)-224-5304 FAX: (971)-224-5313 OREGON CCB 44712 CROMWELL FIRE 72ND AVE APARTMENTS 11740 SW 72ND AVENUE, TIGARD, OREGON FIRE PROTECTION HYDRAULIC CALCULATIONS EQUIPMENT SUBMITTALS OFFICE Copy OFFICE Gr- CROMWELL FIRE SYSTEMS • 25599 SW 59TH AVENUE; WILSONVILLE, OREGON 97070 PHONE: (971)-224-5304 FAX: (971)-224-5313 OREGON CCB 44712 .1..1.-tCEIVE1) DEC 26 CITY Of TD1-16vikiRsii)ON 513.11,DING cRomwELL FIRE 72ND AVE APARTMENTS o 7:47 . ,\c,v, ...... i 1110,, 'If a....0 0„ 11740 SW 72ND AV ENUE, , ,e0., W ir TIGARD, OREGON 77506 PE 12-21-201' ,, OREGON ((s 10 4,941, R y- , \\\N„...... L . 0 r:Cels Vi EXPIRATION DATE:12/31/20 IIILI, ARCHITECTS FIRE PROTECTION DB NO EXCEPTION TAKEN HTDRAtittC CALCULATIONS 0 REJECTED REV ISE AND RIESUBM 11 0 SUBMIT SPECIFIED ITEM This review is only for general conformance with the design concept of the protect and general compliance with the infortmtion given in the contract documents. Any actions shown remaining are sul*ct to the requirements of the contract documents.Contractor is responsible tar all physical requirements confirmed az the job site.including but not limited to confirming arreitanne dimensions at iotnate for tolerance,clearance.quantities,fabrication,procems . techniques.. of the construction, cocirdmatton of his wt with other trades and full ,ottimiance with contract,documents.Contract-7 t.,77 re-+ sit or all delays d i o rej. ion I tills submtual i / ate23-Dec-2018 TUALATIN VALLEY WATER DISTRICT Test#: 1332 FIRE HYDRANT FLOW TEST REPORT Hydrant ID #: 1S1W36D23FH50 Location: SW 72ND AVE & SW CLINTON ST Date: 7/17/2018 Test made by: BEN &JEFF Witness: Time: 12:40 Project name: Discharge coefficient: .54816 Inside dia. of outlet= 4,5 inches Pitot reading = 48 psi Pitot 2 = p psi Observed flow rate = 2293.3 gpm Flow method: HOSE MONSTER Static pressure: 110 psi Residual pressure: 91 psi 7.4 Flow at 20psi residual pressure (calculated): 5312 gpm Location map: To be attached to test report and to show which hydrants were used to monitor residual pressure and flow. / 7 Gags information: Static and residual pressure gage: 206778 Pitot gage 206320 Hydrant information: Hydrant ID Year Make ates Flow hydrant: 1S1W36D23FH50 1999 CLOW see map for location Read hydrant: 1 S1 W36D22FH50 1977 WATEROUS see map for location Remarks: The mapping,flow or pressure information contained herein reflects conditions on the date and time of the test. Tualatin Valley Water District makes no representation as to the system's ability to meet specific fire flow requirements. Future system capability may differ from the flows reported herein because of subsequent modifications to the district's system and/or because flow and pressure may vary by time of day and season. Test gage callibratlon Information available upon request. 411 s ----- S T ATLANTA 61 A.rLA 1 TA ST. , al — w .Y w . 1 Qle Fr c #6038 eromw 1 -- j d'T8 1 °°" ' BAYLOR ti t.,,,s • ST I / DUVALL (A�►an.. ed) ilex, 1 I troc,CtI I --X le, El,- i I DOA❑ 1 ji _________ 0 1 Q ` CLINTON ": ■ � /!� i .�1CY PCI 1 .r� CV V, tr. z r k �t,; a ti s. Lmo _,__..O ST a + ______ , , _ _,_, i I . , ___I i ,,, I j 1 /7016 #67,2 CO �e 1$ .�� F Nh, ' (/5379 1 #6919 rep try L°A A,,./.__i #t i81 i a 0 • 0 CALCULATION SUMMARY Project Name:72ND AVE APTS Project Location: 11740 SW 72ND AVE Drawing No.: City: TIGARD, OREGON Design Areas Design Area Calc. Mode Occupancy Area of Total Water Pressure @ Min. Min. Min. Calculated Hose Margin To Name (Model) Application Source Density Pressure Flow Heads Streams Source (ft') (gpm) (psi) (gpmfft2) (psi) (gpm) # (gpm) (psi) 1 Demand (HW) LIGHT 376 206.5 Required 0.1 27.3 25.6 4 100 15.1 94.7 File:C:\Users\lonnie\Documents\cromwell\72nd Ave Apts\72ND AVE(TIGARD 37)-WORKING FILE.dwg Date 12/5/2018 Copyright©2002-2012 Tyco Fire Protection Products • Page 1 III • HYDRAULIC CALCULATIONS for • Job Information Project Name:72ND AVE APTS Contract No. : City: TIGARD, OREGON Project Location: 11740 SW 72ND AVE Date:11/13/2018 Contractor Information Name of Contractor: CROMWELL FIRE Address: 25599 SW 95TH AVE City: WILSONVILLE, OREGON 97070 Phone Number: 971-224-5304 E-mail:lonniel@cromwellinc.com Name of Designer: LONNIE LARSEN Authority Having Jurisdiction: TBD Design Remote Area Name 1 Remote Area Location 5TH FLOOR WET Occupancy Classification LIGHT Density(gpm/ft2) 0.1 Air Area of Application(ft2) 376 ,`<cFt tta► 0� Coverage per Sprinkler(ft2) 256 • iC Number of Calculated Sprinklers 4 77506 PE 12-21 -201 In-Rack Demand(gpm) 0 v A,OREGON ( )> Special Heads �/P,o E 10 0 � Hose Streams(gpm) 100 EXPIRATION DATE:12/31/20 Total Water Required(incl.Hose Streams)(gpm) 206.5 Required Pressure at Source(psi) 94.7 Type of System Wet Volume-Entire System (gal) 1168.3 gal Water Supply Information Date 7/17/2018 Location SW 72ND AVE&SW CLINTON ST Source WI Notes 4 HEADS @ 256FT2(16'-0"X 16'-0") File:C:\Users\lonnie\Documents\cromwell\72nd Ave Apts\72ND AVE(TIGARD 37)-WORKING FILE.dwg Date 12/5/2018 Copyright©2002-2012 Tyco Fire Protection Products Page 2 Job:72ND AVE APTS Node Labels: Off Pipe Labels: Off Diagram for Design Area : 1 (Optimized Hydraulic Simolifiedl 9.. y..1 File:C:\Users\lonnie\Documents\cromwell\72nd Ave Apts\72ND AVE(TIGARD 37)-WORKING FILE.dwg Date 12/5/2018 Copyright©2002-2012 Tyco Fire Protection Products Page 3 • Job:72ND AVE APTS Hydraulic Analysis for : 1 • Calculation Info Calculation Mode Demand Hydraulic Model Hazen-Williams Fluid Name Water @ 60F (15.6C) Fluid Weight, (Ib/ft3) N/A for Hazen-Williams calculation. Fluid Dynamic Viscosity, (lb•s/ft2) N/A for Hazen-Williams calculation. Water Supply Parameters Supply 1 :W1 Flow(gpm) Pressure(psi) 0 110 2293 91 5312 20 Supply Analysis Residual Available Static Pressure Flow Total Demand Required Pressure Node at Source Pressure Pressure (psi) (psi) (gpm) (psi) (gpm) (psi) W1 110 91 2293 109.8 206.5 94.7 Hoses Inside Hose Flow/Standpipe Demand(gpm) 50 Outside Hose Flow(gpm) 50 IIIAdditional Outside Hose Flow(gpm) Other(custom defined) Hose Flow(gpm) 0 Total Hose Flow(gpm) 100 Sprinklers Ovehead Sprinkler Flow(gpm) 106.5 InRack Sprinkler Flow(gpm) 0 Other(custom defined)Sprinkler Flow(gpm) 0 Total Sprinkler Flow(gpm) 106.5 Other Required Margin of Safety(psi) 0 W1 -Pressure(psi) 94.7 W1 -Flow(gpm) 206.5 Demand w/o System Pump(s) N/A • File:C:\Users\lonnie\Documents\cromwell\72nd Ave Apts\72ND AVE(TIGARD 37)-WORKING FILE.dwg Date 12/5/2018 Copyright©2002-2012 Tyco Fire Protection Products Page 4 Job:72ND AVE APTS Hydraulic Analysis for : 1 at System Demand 0 Available At Source 150 140 1301 109.8 psi @206.5gpm, 110 I\ 14(Jai 90 Q ai 80 u) 70 L a \ 60- 50 40 S3 @ 20 10 2.752 0. 0 2000 2500 3000 3500 4000 4500 5000 5500 6000 Flow,gpm File:C:\Users\lonnie\Documents\cromwell\72nd Ave Apts\72ND AVE(TIGARD 37)-WORKING FILE.dwg Date 12/5/2018 Copyright©2002-2012 Tyco Fire Protection Products Page 5 • • • Job:72ND AVE APTS Hydraulic Analysis for : 1 • Graph Labels Values Label Description Flow (gpm) Pressure (psi) S1 Supply point#1 -Static 0 110 S2 Supply point#2 2293 91 S3 Supply point#3 5312 20 D1 Elevation Pressure 0 23 D2 System Demand 206.5 94.7 Curve Intersections & Safety Margins Intersection Safety Margin Curve Name Pressure (psi) Flow (gpm) Pressure (psi) @ Flow (gpm) Supply 109.7 228.8 15.1 206.5 Open Heads Required Calculated Head Ref. Head Type Coverage K-Factor Density Flow Pressure Density Flow Pressure (ft2) (gpm/psi1/2) (gpm/ft2) (gpm) (Psi) (gpm/ft2) (gpm) (psi) 101 Overhead 256 4.9 0.1 25.6 27.3 0.1 25.6 27.3 IIISprinkler 102 Overhead 256 4.9 0.1 25.6 27.3 0.105 26.9 30.1 I Sprinkler 103 Overhead 256 4.9 0.1 25.6 27.3 0.103 26.4 28.9 Sprinkler 104 Overhead 256 4.9 0.1 25.6 27.3 0.108 27.7 31.9 Sprinkler l Ili File:C:\Users\lonnie\Documents\cromwell\72nd Ave Apts\72ND AVE(TIGARD 37)-WORKING FILE.dwg Date 12/5/2018 Copyright©2002-2012 Tyco Fire Protection Products Page 6 Job:72ND AVE APTS Hydraulic Calculations/Fluid Delivery Time Analysis Node Data Node# Type K-Fact. Discharge Coverage Tot. Pres. Req. Pres. • Elev Hgroup Open/Closed Overdischarge Density Elev. Pres. Req. Discharge 9Pm/Psi1/2 gpm ft2 psi psi ft gpm gpm/ft2 psi gpm 101 Overhead Sprinkler 4.9 25.6 256 27.3 27.3 54.08 HEAD Open 0 0.1 -23 25.6 103 Overhead Sprinkler 4.9 26.4 256 28.9 27.3 54.08 HEAD Open 0.8 0.103 -23 25.6 102 Overhead Sprinkler 4.9 26.9 256 30.1 27.3 52.08 HEAD Open 1.3 0.105 -22.1 25.6 104 Overhead Sprinkler 4.9 27.7 256 31.9 27.3 52.08 HEAD Open 2.1 0.108 -22.1 25.6 0451 Node 30.2 53.67 NODE -22.8 0461 Node 32 53.67 NODE -22.8 0443 Node 36 53.67 NODE -22.8 0442 Node 37.7 53.67 NODE -22.8 0426 Node 50.8 53.67 NODE -22.8 0412 Node 61.2 53.67 NODE -22.8 0437 Node 62.3 51.92 NODE -22.1 0401-0 Node 67.3 • 46.49 NODE -19.7 IH1 Inside Hose 68.5 48.58 HOSE 50 -20.6 50 0401-I Node 68.8 45.23 NODE -19.2 0397 Node 70 44.35 NODE -18.8 1315-0 Node 84.6 11.67 NODE -4.6 1315-I Node 84.6 11.67 NODE -4.6 0381-0 Node 84.7 11.67 NODE -4.6 0381-I Node 84.7 11.67 NODE -4.6 0380 Node 84.8 11.67 NODE -4.6 0379-0 Node 86.3 8.34 NODE -3.2 0379-I Node 87.2 6.75 NODE -2.5 0015 Node 92.5 -4 NODE 2.2 0012-0 Node 92.8 -4 NODE 2.2 OH1 Outside Hose 94.6IP 1 HOSE 50 0 50 File:C:\Users\lonnie\Documents\cromwel1\72nd Ave Apts\72ND AVE(TIGARD 37)-WORKING FILE.dwg Date 12/5/2018 Copyright©2002-2012 Tyco Fire Protection Products Page 7 Job:72ND AVE APTS Hydraulic Calculations/Fluid Delivery Time Analysis • Node Data Node# Type K-Fact. Discharge Coverage Tot. Pres. Req. Pres. Elev Hgroup Open/Closed Overdischarge Density Elev. Pres. Req. Discharge sig/z gpm ft2 psi psi ft gpm/p gpm gpm/ft2 psi gpm W1 Supply -206.5 94.7 1 SUPPLY 0 0012-I Node 96.7 -4 NODE 2.2 0010 Node 96.8 -4 NODE 2.2 0003 Node 96.8 -4 NODE 2.2 0004 Node 96.8 -4 NODE 2.2 0005 Node 96.8 -4 NODE 2.2 • • File:C:\Users\lonnie\Documents\cromwell\72nd Ave Apts\72ND AVE(TIGARD 37)-WORKING FILE.dwg Date 12/5/2018 Copyright©2002-2012 Tyco Fire Protection Products Page 8 Job:72ND AVE APTS Hydraulic Calculations PIPE INFORMATION Node 1 Elev 1 K-Factor 1 Flow added (q) Nominal ID Fittings L C Factor total (Pt) Node 2 Elev 2 K-Factor 2 Total flow (Q) Actual ID quantity x (name) = length F Pf per ft elev (Pe) NOTES T frict(Pf) (ft) (gpm/psi1/2) (gpm) (in) (ft) ((t) (Psi) (psi) Path No: 1 101 54.08 4.9 25.6 1 lx(BM.Tee-Run)=1 9.58 150 27.3 0451 53.67 25.6 1.101 2x(BM.90)=10 16 0.107 0.2 lx(BM.Tee-Br)=5 25.58 2.7 0451 53.67 26.9 1 lx(BM.Tee-Run)=1 8.4 150 30.2 0443 53.67 52.5 1.101 lx(BM.Tee-Br)=5 6 0.4047 0 14.4 5.8 0443 53.67 0 1.25 1x(BM.Tee-Run)=1 12 150 36 0442 53.67 52.5 1.394 1 0.1283 0 13 1.7 0442 53.67 54 1.25 1x(BM.Tee-Run)=1 20.55 150 37.7 0426 53.67 106.5 1.394 1x(BM.Tee-Br)=6 7 0.4755 0 27.55 13.1 0426 53.67 0 2 1x(BM.Tee-Br)=10 78.18 150 50.8 0412 53.67 106.5 2.003 10x(BM.Tee-Run)=10 50 0.0814 0 3x(BM.90)=30 128.18 10.4 0412 53.67 0 2.5 lx(us.90)=8.27 1.75 150 61.2 0437 51.92 106.5 2.423 8.27 0.0322 0.8 10.02 0.3 0437 51.92 0 2.5 lx(coupling)=1.37 22.73 120 62.3 0401-0 46.49 106.5 2.635 7x(us.90)=57.66 59.03 0.0324 2.3 81.76 2.6 0401-0 46.49 0 2.5 1.26 0 67.3 GLOBE - UMC IO 0401-I 45.23 106.5 0 0 0.7589 0.5 MANIFOLD 1.26 1 *** 0401-I 45.23 0 2.5 1x(us.Tee-Br)=16.47 1.57 120 68.8 0397 44.35 106.5 2.635 1x(us.90)=8.24 24.71 0.0324 0.4 26.28 0.9 0397 44.35 0 4 lx(coupling)=1.32 53.59 120 70 0381-0 11.67 106.5 4.26 5x(us.90)=65.84 93.49 0.0031 14.2 lx(us.Tee-Br)=26.33 147.08 0.5 0381-0 11.67 0 4 0.39 0 84.7 VIC-705 0381-I 11.67 106.5 0 0 0.0303 0 *** 0.39 0.0 0381-I 11.67 0 4 lx(us.Tee-Br)=26.33 2 120 84.7 0380 11.67 106.5 4.26 26.33 0.0031 0 28.34 0.1 0380 11.67 50 4 1x(coupling)=1.32 5.45 120 84.8 0379-0 8.34 156.5 4.26 1x(us.90)=13.17 14.48 0.0064 1.4 19.93 0.1 0379-0 8.34 0 4 1.59 0 86.3 GLOBE - UMC 0379-I 6.75 156.5 0 0 0.1186 0.7 MANIFOLD 1.59 0.2 *** 0379-I 6.75 0 4 3x(us.90)=39.5 20.5 120 87.2 0015 -4 156.5 4.26 2x(us.45)=10.53 76.37 0.0064 4.7 1x(us.Tee-Br)=26.33 96.87 0.6 0015 -4 0 4 1x(coupling)=1.83 52.76 140 92.5 0012-0 -4 156.5 4.3 1x(us.90)=18.33 20.16 0.0046 0 72.92 0.3 • File:C:\Users\lonnie\Documents\cromwell\72nd Ave Apts\72ND AVE(TIGARD 37)-WORKING FILE.dwg Date 12/5/2018 Copyright©2002-2012 Tyco Fire Protection Products Page 9 Job:72ND AVE APTS Hydraulic Calculations • PIPE INFORMATION Node 1 Elev 1 K-Factor 1 Flow added (q) Nominal ID Fittings L C Factor total (Pt) Node 2 Elev 2 K-Factor 2 Total flow (Q) Actual ID quantity x (name) = length F Pf per ft elev (Pe) NOTES T frict (Pf) (ft) (gpm/psiY2) (gpm) (in) (ft) (ft) (psi) (psi) Path No: 1 0012-0 -4 0 4 2.81 0 92.8 AmesC300H 0012-I -4 156.5 0 0 1.3891 0 *** 2.81 3.9 0012-I -4 0 4 ix(coupling)=1.83 13.35 140 96.7 0010 -4 156.5 4.3 1.83 0.0046 0 15.18 0.1 0010 -4 0 8 1 140 96.8 0003 -4 156.5 8.55 0 0.0002 0 1 0 0003 -4 50 8 lx(us.Tee-Br)=61.64 23.29 140 96.8 0004 -4 206.5 8.55 61.64 0.0003 0 84.92 0.0 0004 -4 0 12 1x(us.Tee-Br)=99.1 120 140 96.8 0005 -4 206.5 12.64 99.1 0.0000 0 219.1 0 0005 -4 0 6 2x(us.90)=48.39 11.5 140 96.8 W1 1 206.5 6.4 48.39 0.0011 -2.2 59.89 0.1 W1 94.7 III Path No: 2 103 54.08 4.9 26.4 1 lx(BM.Tee-Run)=1 9.58 150 28.9 I 0461 53.67 26.4 1.101 2x(BM.90)=10 16 0.1129 0.2 lx(BM.Tee-Br)=5 25.58 2.9 0461 53.67 27.7 1 lx(BM.Tee-Br)=5 8.4 150 32 0442 53.67 54 1.101 5 0.4267 0 13.4 5.7 0442 37.7 Path No: 3 102 52.08 4.9 26.9 1 lx(BM.Tee-Br)=5 1.58 150 30.1 0451 53.67 26.9 1.101 5 0.1173 -0.7 6.58 0.8 0451 30.2 Path No: 4 104 52.08 4.9 27.7 1 1x(BM.Tee-Br)=5 1.58 150 31.9 0461 53.67 27.7 1.101 5 0.1235 -0.7 6.58 0.8 0461 32 • File:C:\Users\lonnie1 Documents\cromwell172nd Ave Apts\72ND AVE(TIGARD 37)-WORKING FILE.dwg Date 12/5/2018 Copyright©2002-2012 Tyco Fire Protection Products Page 10 Job:72ND AVE APTS Hydraulic Calculations PIPE INFORMATION Node 1 Elev 1 K-Factor 1 Flow added (q) Nominal ID Fittings L C Factor total (Pt) Node 2 Elev 2 K-Factor 2 Total flow (Q) Actual ID quantity x (name) = length F Pf per ft elev (Pe) NOTES T frict(Pf) (ft) (gpm/psi') (gpm) (in) (ft) (ft) (psi) (psi) Path No: 5 IH1 48.58 50 4 lx(coupling)=1.32 42.54 120 68.5 1315-0 11.67 50 4.26 lx(us.Tee-Br)=26.33 40.82 0.0008 16 lx(us.90)=13.17 83.36 0.1 1315-0 11.67 0 4 0.39 0 84.6 VIC-705 1315-I 11.67 50 0 0 0.0104 0 *** 0.39 0 1315-I 11.67 0 4 lx(us.Tee-Br)=26.33 138 120 84.6 0380 11.67 50 4.26 7x(us.90)=92.17 118.5 0.0008 0 256.5 0.2 0380 84.8 Path No: 6 OH1 1 50 6 1x(us.Tee-Br)=51.84 15.5 140 94.6 0003 -4 50 6.4 2x(us.90)=48.39 100.23 0.0001 2.2 115.73 0 0003 96.8 * Pressures are balanced to a high degree of accuracy. Values may vary by 0.1 psi due to display rounding. * Maximum Velocity of 22.39 ft/s occurs in the following pipe(s): (0426-0442) *** Device pressure loss (gain in the case of pumps) is calculated from the device's curve. If the device curve is printed with III this report, it will appear below. The length of the device as shown in the table above comes from the CAD drawing. The friction loss per unit of length is calculated based upon the length and the curve-based loss/gain value. Internal ID and C Factor values are irrelevant as the device is not represented as an addition to any pipe, but is an individual item whose loss/gain is based solely on the curve data. • File:C:\Users\lonnie\Documents\cromwell\72nd Ave Apts\72ND AVE(TIGARD 37)-WORKING FILE.dwg Date 12/5/2018 Copyright©2002-2012 Tyco Fire Protection Products Page 11 Job:72ND AVE APTS Device Graphs Pressure vs. Flow Function • Design Area: 1; Supply Ref.:W1; Supply Name:W1 125' 120- 115- 110: 20:II5110 105 10( 95= 90 85= 801 C. 75 70-- 5-N 7 65- (4 60= ` 55. 50.! 45� 40.. 35. 30- 25 20 15._ IO.- 5' o O O C O O O C O N O c, O C O O N OI rn C 7 Oi h Flow,gpm • Pressure Loss Function Design Area: 1; BFP Ref.: 1936 (AmesC300H, Size = 4); Inlet Node: 0012-1; Outlet Node: 0012-0 18.8 17.8- 16.8- 15 82 6.8:15.8= 14.8..:. 13.R.;^ 12.8.:: U! 1 1.8-- 0- dc 10.8.: 9.8.;- y 8.8. a 7.8 6.8 5.8-- 3.9 psi @156.5gpm; 4.8-. 3.8.; 2.8 1.8. 0.8' • _ x o 0 0 0 O c 0 0 0 V' O 0 o O o 0 000 Flow,gpm File:C:\Users\lonnie\Documents\cromwell\72nd Ave Apts\72ND AVE(TIGARD 37)-WORKING FILE.dwg Date 12/5/2018 Copyright©2002-2012 Tyco Fire Protection Products Page 12 Job:72ND AVE APTS Device Graphs Pressure Loss Function Design Area: 1; Valve Ref.: 1941 (GLOBE - UMC MANIFOLD, Size = 4); Inlet Node: 0379-I; Outlet Node: 0379-0. 6.7 s.7- •n- 4.7- 0. G1 I 3 U! 3.7- w d a 7.7 0.7- 0.2 psi @ 156.5 gpm 4 0 O 0 0 0 0 0 O0 O O 0 M V n 0 OC 0 N Flow,gpm Pressure Loss Function II Design Area: 1; Valve Ref.: 1942 (VIC-705, Size = 4); Inlet Node: 0381-I; Outlet Node: 0381-0 20.197 _ i . 19.197 _._...-..... 4 4 ..,.�..._ y _ ._... ._.I ..._ ,� t i 1 18_]97_ .. .� s r _j'" "1'"""' 1''' w I. t p 17.197-. _ __ —... 1. ..., ,-'f i 1._.,._ ....._._.E..... 1— 1,..---'�' 1.,. ...... _ -r _ 16.197 1i 1 d 15.197-: ----- J. { -1- { 1 1 _.,_ 4_1_4_4_ i { 14.197i { L_ . _� _a. 1 ._, -,t. k H. ._ 13.197- ; # __iT i C 12.197 } t - 4 _ e. • - _ m 1 1.197, .._. ,...,__...._....1 _._ ._:_...._' .}_ ..._....r_ +-- 1- ..__ -i..._-7»-_ 1. .____..._... ..._._._.;.. .--t-.._ .1� ..._.._.._.. _.e...... 3 CA 10.197 ,—F } , 1 I t ¢ i r d 9.197 - +?-_-...�..� ... w_g...„,„.„ _.�. _..._._w.L.... �.1...,�� _._..._ .. i CC 8.197. ... . t - ---t ±'—4- 7.197: f. e #. 1 t ?. _ R,_ 1-.v_-._..A } ... 6.197.7 m.l..,.,..,.....V._,1 .i.....�.,__'#.____....-1---- .__ _..p.._W_ii—_ �.."i �.� i I__ � 5.1977; -- -- — - -- .-- 4.197- 3197- 2.197 _ , 1-- - ,__�.:_.... 0.0 psi @ 106.5 gpm 1.197-' 0.197--, , C , 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 V 00 0 0 0 00 00 0 0 0 0 0 0 O 0 0 0 0 0 N N n m 7 0 00 00 01 O N V - _ N N N Nm • Flow,gpm~ m File:C:\Users\lonnie\Documents\cromwell\72nd Ave Apts\72ND AVE(TIGARD 37)-WORKING FILE.dwg Date 12/5/2018 Copyright©2002-2012 Tyco Fire Protection Products Page 13 Job:72ND AVE APTS Device Graphs Pressure Loss Function • Design Area: 1; Valve Ref.: 1943 (GLOBE - UMC MANIFOLD, Size = 2.5); Inlet Node: 0401-I; Outlet Node: 0401-0 6.7.. 5.7- •y 4.7- u)• 3.7- U) d a 2.7- 1.7- 1 .7-1.71 psi @ 106.5 gpm 0.7. 0 o 0 o 0 0 0 0 o r o 0 N M Flow,gpm • Pressure Loss Function Design Area: 1; Valve Ref.: 1947 (VIC-705, Size = 4); Inlet Node: 1315-I; Outlet Node: 1315-0 20.197:- 19.197: 18.197 17.197. 16.197- 15.197- 14.197- y 13.197- a. 12.197- 11.197- 2 N 10.197;` u CI. 8.197 7.197_- 6.197 5.197._ .. 4.197= 3.197- 2.197 0 psi @ 50 gpm i 1.197 - 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 ^ o o N _ o z o 0 0 0 0 0 0 0 0 0 0 v n rn o N v o0 0 .o Flow,gpm File:C:\Users\lonnie\Documents\cromwell\72nd Ave Apts\72ND AVE(TIGARD 37)-WORKING FILE.dwg Date 12/5/2018 Copyright©2002-2012 Tyco Fire Protection Products Page 14 CALCULATION SUMMARY Project Name:72ND AVE APTS Project Location: 11740 SW 72ND AVE Drawing No. : City: TIGARD, OREGON Design Areas Design Area Calc. Mode Occupancy Area of Total Water Pressure @ Min. Min. Min. Calculated Hose Margin To Name (Model) Application Source Density Pressure Flow Heads Streams Source (ft2) (gpm) (psi) (gpm/ft2) (psi) (gpm) # (gpm) (psi) 2 Demand (HW) LIGHT 2564 612 Required 0.114 7 14.8 29 100 26.7 81.6 File:C:\Users\lonnie\Documents\cromwell\72nd Ave Apts\72ND AVE(TIGARD 37)-WORKING FILE.dwg Date 12/5/2018 Copyright©2002-2012 Tyco Fire Protection Products • Page 1 • III HYDRAULIC CALCULATIONS for • Job Information Project Name:72ND AVE APTS Contract No.: City: TIGARD, OREGON Project Location: 11740 SW 72ND AVE Date: 11/13/2018 Contractor Information Name of Contractor: CROMWELL FIRE Address: 25599 SW 95TH AVE City: WILSONVILLE, OREGON 97070 Phone Number: 971-224-5304 E-mail:lonniel@cromwellinc.com Name of Designer: LONNIE LARSEN Authority Having Jurisdiction: TBD Design Remote Area Name 2 Remote Area Location ATTIC-DRY Occupancy Classification LIGHT Density(gpm/ft2) 0.114 ,ccs-ck � 1 Area of Application(ft2) 2564 ., /f 411,tik Coverage per Sprinkler(ft2) 130 C 775012-21 PE 12--2121 -2018 • Number of Calculated Sprinklers 29 OREGONco RIn-Rack Demand(gpm) 0 </<(‘ L 0 "�P� Special Heads EXPIRATION DATE:12/31/20 Hose Streams(gpm) 100 Total Water Required(incl.Hose Streams)(gpm) 612 Required Pressure at Source(psi) 81.6 Type of System Dry Volume-Downstream DPV (gal) 468.3 gal Water Supply Information Date 7/17/2018 Location SW 72ND AVE&SW CLINTON ST Source W1 Notes LIGHT HAZARD @ 130FT2 PER HEAD • File:C:\Users\lonnie\Documents\Cromwell\72nd Ave Apts\72ND AVE(TIGARD 37)-WORKING FILE.dwg Date 12/5/2018 Copyright©2002-2012 Tyco Fire Protection Products Page 2 Job:72ND AVE APTS Node Labels: Off Pipe Labels: Off Diagram for Design Area : 2 (Ootimized Hydraulic Simalifiedl . .- I 1 ., . 7 vtY ob. File:C:\Users\Ionnie\Documents\cromwell\72nd Ave Apts\72ND AVE(TIGARD 37)-WORKING FILE.dwg Date 12/512018 Copyright©2002-2012 Tyco Fire Protection Products Page 3 0 • • Job:72ND AVE APTS Hydraulic Analysis for : 2 • Calculation Info Calculation Mode Demand Hydraulic Model Hazen-Williams Fluid Name Water @ 60F (15.6C) Fluid Weight, (Ib/ft3) N/A for Hazen-Williams calculation. Fluid Dynamic Viscosity, (Ib•s/ft2) N/A for Hazen-Williams calculation. Water Supply Parameters Supply 1 :W1 Flow(gpm) Pressure(psi) 0 110 2293 91 5312 20 Supply Analysis Residual Available Static Pressure Flow Total Demand Required Pressure Node at Source Pressure Pressure (psi) (psi) (gpm) (psi) (9pm) (psi) W1 110 91 2293 108.3 612 81.6 Hoses Inside Hose Flow/Standpipe Demand(gpm) 50 Outside Hose Flow(gpm) 50 • Additional Outside Hose Flow(gpm) Other(custom defined) Hose Flow(gpm) 0 Total Hose Flow(gpm) 100 Sprinklers Ovehead Sprinkler Flow(gpm) 512 InRack Sprinkler Flow(gpm) 0 Other(custom defined)Sprinkler Flow(gpm) 0 Total Sprinkler Flow(gpm) 512 Other Required Margin of Safety(psi) 0 W1 -Pressure(psi) 81.6 W1 -Flow(gpm) 612 Demand w/o System Pump(s) N/A • File:C:\Users\lonnie\Documents\cromwell\72nd Ave Apts172ND AVE(TIGARD 37)-WORKING FILE.dwg Date 12/5/2018 Copyright©2002-2012 Tyco Fire Protection Products Page 4 Job:72ND AVE APTS Hydraulic Analysis for : 2 System Demand 0 Available At Source 150 140 130 108.3 psi @612gpm " 110 100 S2 9q D2 ad 80 Ns cn 3 70 a N60 50 40. D1 1 [ S3 20 10.. -2.752 0 2000 2500 3000 3500 4000 4500 5000 5500 6000 Flow,gpm File:C:\Users\lonnie\Documents\cromwell\72nd Ave Apts\72ND AVE(TIGARD 37)-WORKING PII-E,dwg Date 12/5/2018 Copyright n 2002-2012 Tyco Fire Protection Products Page 5 • • • Job:72ND AVE APTS Hydraulic Analysis for : 2 • Graph Labels Label Description Values Flow (gpm) Pressure (psi) S1 Supply point#1 -Static 0 110 S2 Supply point#2 2293 91 S3 Supply point#3 5312 20 D1 Elevation Pressure 0 26 D2 System Demand 612 81.6 Curve Intersections & Safety Margins Intersection Safety Margin Curve Name Pressure (psi) Flow (gpm) Pressure (psi) @ Flow (gpm) Supply 107.6 752.6 26.7 612 Open Heads Required Calculated Head Ref. Head Type Coverage K-Factor Density Flow Pressure Density Flow Pressure (ft2) (gpm/Psi'/2) (gpm/ft2) (gpm) (psi) (gpm/ft2) (gpm) (psi) 201 Overhead 130 5.6 0.1 13 7 0.122 15.8 8 • Sprinkler 202 Overhead 130 5.6 0.1 13 7 0.114 14.8 7 Sprinkler 203 Overhead 130 5.6 0.1 13 7 0.164 21.4 14.6 Sprinkler 204 Overhead 130 5.6 0.1 13 7 0.135 17.6 9.9 Sprinkler 205 Overhead 130 5.6 0.1 13 7 0.159 20.6 13.6 Sprinkler 206 Overhead 130 5.6 0.1 13 7 0.159 20.6 13.6 Sprinkler 207 Overhead 130 5.6 0.1 13 7 0.129 16.8 9 Sprinkler 208 Overhead 130 5.6 0.1 13 7 0.137 17.9 10.2 Sprinkler 209 Overhead 130 5.6 0.1 13 7 0.125 16.2 8.4 Sprinkler 210 Overhead 130 5.6 0.1 13 7 0.132 17.2 9.4 Sprinkler 211 Overhead 130 5.6 0.1 13 7 0.121 15.7 7.9 Sprinkler 212 Overhead 130 5.6 0.1 13 7 0.126 16.3 8.5 IIISprinkler 213 Overhead 130 5.6 0.1 13 7 0.12 15.6 7.8 Sprinkler File:C:\Users\lonnie\Documents\cromwell\72nd Ave Apts\72ND AVE(TIGARD 37)-WORKING FILE.dwg Date 12/5/2018 Copyright©2002-2012 Tyco Fire Protection Products Page 6 214 Overhead 130 5.6 0.1 13 7 0.155 20.1 12.9 Sprinkler 215 Overhead 130 5.6 0.1 13 7 0.144 18.7 11.2 Sprinkler • 216 Overhead 130 5.6 0.1 13 7 0.125 16.2 8.4 Sprinkler 217 Overhead 130 5.6 0.1 13 7 0.143 18.7 11.1 Sprinkler 218 Overhead 130 5.6 0.1 13 7 0.145 18.8 11.3 Sprinkler 219 Overhead 130 5.6 0.1 13 7 0.156 20.3 13.2 Sprinkler 220 Overhead 130 5.6 0.1 13 7 0.14 18.1 10.5 Sprinkler 221 Overhead 130 5.6 0.1 13 7 0.13 16.9 9.1 Sprinkler 222 Overhead 130 5.6 0.1 13 7 0.12 15.5 7.7 Sprinkler 223 Overhead 130 5.6 0.1 13 7 0.153 19.8 12.5 Sprinkler 224 Overhead 130 5.6 0.1 13 7 0.129 16.8 9 Sprinkler 225 Overhead 130 5.6 0.1 13 7 0.126 16.3 8.5 Sprinkler 226 Overhead 130 5.6 0.1 13 7 0.149 19.4 11.9 Sprinkler • 227 Overhead 130 5.6 0.1 13 7 0.134 17.5 9.7 Sprinkler 228 Overhead 130 5.6 0.1 13 7 0.127 16.5 8.6 Sprinkler 229 Overhead 130 5.6 0.1 13 7 0.121 15.7 7.9 Sprinkler • File:C:\Users\lonnie\Documents\cromwell\72nd Ave Apts\72ND AVE(TIGARD 37)-WORKING FILE.dwg Date 12/5/2018 Copyright©2002-2012 Tyco Fire Protection Products Page 7 Job:72ND AVE APTS Hydraulic Calculations/Fluid Delivery Time Analysis • Node Data Node# Type K-Fact. Discharge Coverage Tot. Pres. Req. Pres. Elev Hgroup Open/Closed Overdischarge Density Elev. Pres. Req. Discharge gpm ft2 psi psi ft gpm/psig 2 gpm gpm/ft2 psi gpm 202 Overhead Sprinkler 5.6 14.8 130 7 7 61 HEAD Open 1.8 0.114 -26 13 222 Overhead Sprinkler 5.6 15.5 130 7.7 7 59.67 HEAD Open 2.5 0.12 -25.4 13 213 Overhead Sprinkler 5.6 15.6 130 7.8 7 61 HEAD Open 2.6 0.12 -26 13 229 Overhead Sprinkler 5.6 15.7 130 7.9 7 56.75 HEAD Open 2.7 0.121 -24.2 13 211 Overhead Sprinkler 5.6 15.7 130 7.9 7 61 HEAD Open 2.7 0.121 -26 13 201 Overhead Sprinkler 5.6 15.8 130 8 7 58 HEAD Open 2.8 0.122 -24.7 13 216 Overhead Sprinkler 5.6 16.2 130 8.4 7 61 HEAD Open 3.2 0.125 -26 13 209 Overhead Sprinkler 5.6 16.2 130 8.4 7 61 HEAD Open 3.2 0.125 -26 13 212 Overhead Sprinkler 5.6 16.3 130 8.5 7 61 HEAD Open 3.3 0.126 -26 13 225 Overhead Sprinkler 5.6 16.3 130 8.5 7 57.5 HEAD Open 3.3 0.126 -24.5 13 228 Overhead Sprinkler 5.6 16.5 130 8.6 7 • 56.75 HEAD Open 3.5 0.127 -24.2 13 224 Overhead Sprinkler 5.6 16.8 130 9 7 59.58 HEAD Open 3.8 0.129 -25.4 13 207 Overhead Sprinkler 5.6 16.8 130 9 7 61 HEAD Open 3.8 0.129 -26 13 221 Overhead Sprinkler 5.6 16.9 130 9.1 7 59.58 HEAD Open 3.9 0.13 -25.4 13 210 Overhead Sprinkler 5.6 17.2 130 9.4 7 56.5 HEAD Open 4.2 0.132 -24 13 227 Overhead Sprinkler 5.6 17.5 130 9.7 7 56.83 HEAD Open 4.5 0.134 -24.2 13 204 Overhead Sprinkler 5.6 17.6 130 9.9 7 61 HEAD Open 4.6 0.135 -26 13 208 Overhead Sprinkler 5.6 17.9 130 10.2 7 56.5 HEAD Open 4.9 0.137 -24 13 220 Overhead Sprinkler 5.6 18.1 130 10.5 7 56.83 HEAD Open 5.1 0.14 -24.2 13 217 Overhead Sprinkler 5.6 18.7 130 11.1 7 61 HEAD Open 5.7 0.143 -26 13 215 Overhead Sprinkler 5.6 18.7 130 11.2 7 57.5 HEAD Open 5.7 0.144 -24.5 13 218 Overhead Sprinkler 5.6 18.8 130 11.3 7 61 HEAD Open 5.8 0.145 -26 13 226 Overhead Sprinkler 5.6 19.4 130 11.9 7 56.67 HEAD Open 6.4 0.149 -24.1 13 223 Overhead Sprinkler 5.6 19.8 130 12.5 7 • 57.42 HEAD Open 6.8 0.153 -24.4 13 214 Overhead Sprinkler 5.6 20.1 130 12.9 7 56.67 HEAD Open 7.1 0.155 -24.1 13 File:C:\Users\lonnie\Documents\cromwell\72nd Ave Apts\72ND AVE(TIGARD 37)-WORKING FILE.dwg Date 12/5/2018 Copyright©2002-2012 Tyco Fire Protection Products Page 8 Job:72ND AVE APTS Hydraulic Calculations/Fluid Delivery Time Analysis Node Data Node# Type K-Fact. Discharge Coverage Tot. Pres. Req. Pres. • Elev Hgroup Open/Closed Overdischarge Density Elev. Pres. Req. Discharge gpm ft2 psi psi ft gpm/psig/z gpm gpm/ft2 psi gpm 219 Overhead Sprinkler 5.6 20.3 130 13.2 7 56.67 HEAD Open 7.3 0.156 -24.1 13 205 Overhead Sprinkler 5.6 20.6 130 13.6 7 59 HEAD Open 7.6 0.159 -25.1 13 206 Overhead Sprinkler 5.6 20.6 130 13.6 7 61 HEAD Open 7.6 0.159 -26 13 203 Overhead Sprinkler 5.6 21.4 130 14.6 7 57 HEAD Open 8.4 0.164 -24.3 13 0190 Node 9.6 56.37 NODE -24 0283 Node 9.9 56.38 NODE -24 0181 Node 10.3 56.41 NODE -24 0276 Node 10.7 56.4 NODE -24 0179 Node 11.3 56.43 NODE -24 0184 Node 11.4 56.39 NODE -24 0175 Node 11.5 56.46 NODE -24 0186 Node 11.8 • 56.37 NODE -24 0280 Node 12.1 56.38 NODE -24 0174 Node 12.4 56.43 NODE -24 0282 Node 13.1 56.34 NODE -24 0169 Node 14.8 56.46 NODE -24 0168 Node 14.8 56.44 NODE -24 0167 Node 14.9 56.41 NODE -24 0166 Node 14.9 56.37 NODE -24 0165 Node 15 56.35 NODE -24 0164 Node 15 56.35 NODE -24 0163 Node 15.1 56.34 NODE -24 0162 Node 15.2 56.31 NODE -24 0161 Node 15.3 56.31 NODE -24 0160 Node 15.4 • 56.29 NODE -24 File:C:\Users\lonnie\Documents\cromwell\72nd Ave Apts\72ND AVE(TIGARD 37)-WORKING FILE.dwg Date 12/5/2018 Copyright©2002-2012 Tyco Fire Protection Products Page 9 Job:72ND AVE APTS Hydraulic Calculations/Fluid Delivery Time Analysis • Node Data Node# Type K-Fact. Discharge Coverage Tot. Pres. Req. Pres. Elev Hgroup Open/Closed Overdischarge Density Elev. Pres. Req. Discharge 9Pm/Psi1/2 gpm ft2 psi psi ft gpm gpm/ft2 psi gpm 0275 Node 15.9 56.38 NODE -24 0273 Node 17.7 56.37 NODE -24 0272 Node 17.8 56.34 NODE -24 0271 Node 17.8 56.33 NODE -24 0270 Node 17.8 56.33 NODE -24 0143 Node 20.4 56 NODE -23.8 IH1 Inside Hose50 41.4 48.58 HOSE -20.6 50 0024-0 Node 56.3 6.75 NODE -2.5 1315-0 Node 57.5 11.67 NODE -4.6 1315-I Node 57.5 11.67 NODE -4.6 0024-I Node 59 • 5.5 NODE -1.9 0379-0 Node 59.2 8.34 NODE -3.2 0023-0 Node 59.9 3.88 NODE -1.2 0379-I Node 59.9 6.75 NODE -2.5 0023-I Node 60.4 3.5 NODE -1.1 0021 Node 61.8 2.5 NODE -0.6 0015 Node 69.1 -4 NODE 2.2 0012-0 Node 72.6 -4 NODE 2.2 OH1 Outside Hose50 80.9 1 HOSE 0 50 WI Supply -612 81.6 1 SUPPLY 0 0012-I Node 82.3 -4 NODE 2.2 0010 Node 83.1 -4 NODE 2.2 0003 Node 83.1 -4 NODE 2.2 0004 Node 83.3 • -4 NODE 2.2 0005 Node 83.3 -4 NODE 2.2 File:C:\Users\lonnie\Documents\cromwell\72nd Ave Apts\72ND AVE(TIGARD 37)-WORKING FILE.dwg Date 12/5/2018 Copyright©2002-2012 Tyco Fire Protection Products Page 10 Job:72ND AVE APTS Hydraulic Calculations PIPE INFORMATION Node 1 Elev 1 K-Factor 1 Flow added (q) Nominal ID Fittings L C Factor total (Pt) Node 2 Elev 2 K-Factor 2 Total flow (Q) Actual ID quantity x (name) = length F Pf per ft elev (Pe) NOTES T frict(Pf) (ft) (gpm/psi1/2) (gpm) (in) (ft) (ft) (psi) (psi) Path No: 1 202 61 5.6 14.8 1 lx(us.Tee-Br)=3.56 4.62 100 7 0283 56.38 14.8 1.049 3.56 0.1043 2 8.19 0.9 0283 56.38 15.8 1 8 100 9.9 0282 56.34 30.6 1.049 0 0.4003 0.0 8 3.2 0282 56.34 17.6 1 lx(us.Tee-Br)=3.56 1.5 100 13.1 0270 56.33 48.2 1.049 3.56 0.9278 0 5.07 4.7 0270 56.33 130.7 4 1x(us.Tee-Br)=18.78 149.45 100 17.8 0143 56 178.9 4.26 5x(us.90)=46.94 65.72 0.0114 0.1 215.17 2.5 0143 56 333.1 4 lx(coupling)=0.94 87.49 100 20.4 0024-0 6.75 512 4.26 6x(us.90)=56.33 94.82 0.0801 21.3 2x(us.Tee-Br)=37.55 182.31 14.6 0024-0 6.75 0 4 1.25 0 56.3 NXT-768 0024-I 5.5 512 0 0 1.7124 0.5 *** 1.25 2.1 0024-I 5.5 0 4 lx(coupling)=1.32 1.63 120 59 0023-0 3.88 512 4.26 1.32 0.0571 0.7 2.94 0.2 0023-0 3.88 0 4 0.38 0 59.9 VIC-705 • 0023-I 3.5 512 0 0 1.0365 0.2 *** 0.38 0.4 0023-I 3.5 0 4 lx(us.90)=13.17 2.67 120 60.4 0021 2.5 512 4.26 13.17 0.0571 0.4 15.83 0.9 0021 2.5 50 4 3x(us.90)=39.5 16.25 120 61.8 0015 -4 562 4.26 2x(us.45)=10.53 50.03 0.0679 2.8 66.29 4.5 0015 -4 0 4 lx(coupling)=1.83 52.76 140 69.1 0012-0 -4 562 4.3 lx(us.90)=18.33 20.16 0.0488 0 72.92 3.6 0012-0 -4 0 4 2.81 0 72.6 AmesC300H 0012-I -4 562 0 0 3.4568 0 *** 2.81 9.7 0012-I -4 0 4 lx(coupling)=1.83 13.35 140 82.3 0010 -4 562 4.3 1.83 0.0488 0 15.18 0.7 0010 -4 0 8 1 140 83.1 0003 -4 562 8.55 0 0.0017 0 1 0 0003 -4 50 8 lx(us.Tee-Br)=61.64 23.29 140 83.1 0004 -4 612 8.55 61.64 0.002 0 84.92 0.2 0004 -4 0 12 1x(us.Tee-Br)=99.1 120 140 83.3 0005 -4 612 12.64 99.1 0.0003 0 219.1 0.1 • File:C:\Users\lonnie\Documents\cromwell\72nd Ave Apts\72ND AVE(TIGARD 37)-WORKING FILE_dwg Date 12/5/2018 Copyright©2002-2012 Tyco Fire Protection Products Page 11 Job:72ND AVE APTS Hydraulic Calculations • PIPE INFORMATION Node 1 Elev 1 K-Factor 1 Flow added (q) Nominal ID Fittings L C Factor total (Pt) Node 2 Elev 2 K-Factor 2 Total flow (Q) Actual ID quantity x (name) = length F Pf per ft elev (Pe) NOTES T frict (Pf) (ft) (gpm/psi1/2) (gpm) (in) (ft) (ft) (psi) (psi) Path No: 1 0005 -4 0 6 2x(us.90)=48.39 11.5 140 83.3 W1 1 612 6.4 48.39 0.0082 -2.2 59.89 0.5 W1 81.6 Path No: 2 222 59.67 5.6 15.5 1 lx(us.Tee-Br)=3.56 5.14 100 7.7 0181 56.41 15.5 1.049 lx(us.90)=1.43 4.99 0.1139 1.4 10.13 1.2 0181 56.41 16.5 1 1x(us.Tee-Br)=3.56 7.18 100 10.3 0166 56.37 32 1.049 3.56 0.4339 0.0 10.75 4.7 0166 56.37 146.2 4 4.82 100 14.9 0165 56.35 178.2 4.26 0 0.0113 0 4.82 0.1 0165 56.35 31.8 4 1.18 100 15 0164 56.35 210 4.26 0 0.0154 0 1.18 0.0 0164 56.35 33.7 4 2.17 100 15 • 0163 56.34 243.8 4.26 0 0.0203 0 2.17 0.0 0163 56.34 18.7 4 6 100 15.1 0162 56.31 262.4 4.26 0 0.0232 0.0 6 0.1 0162 56.31 32.1 4 2 100 15.2 0161 56.31 294.5 4.26 0 0.0287 0 2 0.1 0161 56.31 18.8 4 4 100 15.3 0160 56.29 313.3 4.26 0 0.0322 0 4 0.1 0160 56.29 19.8 4 2x(us.Tee-Br)=37.55 77.5 100 15.4 0143 56 333.1 4.26 2x(us.90)=18.78 56.33 0.0361 0.1 133.83 4.8 0143 20.4 Path No: 3 213 61 5.6 15.6 1 lx(us.90)=1.43 12.54 100 7.8 0184 56.39 15.6 1.049 1.43 0.115 2 13.97 1.6 0184 56.39 16.2 1 lx(us.Tee-Br)=3.56 4.82 100 11.4 0165 56.35 31.8 1.049 3.56 0.4299 0.0 8.38 3.6 0165 15 III File:C:\Users\lonnie\Documents\cromwell\72nd Ave Apts\72ND AVE(TIGARD 37)-WORKING FILE.dwg Date 12/5/2018 Copyright©2002-2012 Tyco Fire Protection Products Page 12 Job:72ND AVE APTS Hydraulic Calculations PIPE INFORMATION Node 1 Elev 1 K-Factor 1 Flow added (q) Nominal ID Fittings L C Factor total (Pt) Node 2 Elev 2 K-Factor 2 Total flow (Q) Actual ID quantity x (name) = length F Pf per ft elev (Pe) NOTES T frict (Pf) (ft) (qpm/psi1/2) (gpm) (in) (ft) (ft) (psi) (psi) Path No: 4 229 56.75 5.6 15.7 1 2x(us.90)=2.85 10.33 100 7.9 0190 56.37 15.7 1.049 2.85 0.1165 0.2 13.19 1.5 0190 56.37 16.3 1 lx(us.Tee-Br)=3.56 9.32 100 9.6 0162 56.31 32.1 1.049 3.56 0.4356 0.0 12.88 5.6 0162 15.2 Path No: 5 211 61 5.6 15.7 1 1x(us.90)=1.43 12.5 100 7.9 0175 56.46 15.7 1.049 1.43 0.1165 2 13.93 1.6 0175 56.46 16.3 1.25 8 100 11.5 0174 56.43 32.1 1.38 0 0.1145 0.0 8 0.9 0174 56.43 18.7 1.25 lx(us.Tee-Br)=4.28 4.82 100 12.4 0167 56.41 50.8 1.38 4.28 0.2686 0 9.09 2.4 0167 56.41 95.4 4 8.68 100 14.9 0166 56.37 146.2 4.26 0 0.0079 0.0 III 8.68 0.1 0166 14.9 Path No: 6 1 201 58 5.6 15.8 1 1x(us.90)=1.43 8.58 100 8 0283 56.38 15.8 1.049 1.43 0.1177 0.7 10.01 1.2 0283 9.9 Path No: 7 216 61 5.6 16.2 1 lx(us.Tee-Br)=3.56 4.61 100 8.4 0184 56.39 16.2 1.049 3.56 0.1232 2 8.17 1 0184 11.4 Path No: 8 209 61 5.6 16.2 1 1x(us.90)=1.43 12.58 100 8.4 0280 56.38 16.2 1.049 1.43 0.1232 2 14.01 1.7 0280 56.38 16.8 1 lx(us.Tee-Br)=3.56 8.68 100 12.1 0271 56.33 33 1.049 3.56 0.4605 0.0 12.25 5.6 0271 56.33 97.7 4 0.68 100 17.8 0270 56.33 130.7 4.26 0 0.0064 0 0.68 0 0270 17.8 Ili File:C:\Users\lonnie\Documents\cromwell\72nd Ave Apts\72ND AVE(TIGARD 37)-WORKING FILE.dwg Date 12/5/2018 Copyright©2002-2012 Tyco Fire Protection Products Page 13 Job:72ND AVE APTS Hydraulic Calculations • PIPE INFORMATION Node 1 Elev 1 K-Factor 1 Flow added (q) Nominal ID Fittings L C Factor total (Pt) Node 2 Elev 2 K-Factor 2 Total flow (Q) Actual ID quantity x (name) = length F Pf per ft elev (Pe) NOTES T frict(Pf) (ft) (gpm/psis/z) (gpm) (in) (ft) (ft) (psi) (psi) Path No: 9 212 61 5.6 16.3 1 lx(us.Tee-Br)=3.56 4.54 100 8.5 0175 56.46 16.3 1.049 3.56 0.1248 2 8.1 1 0175 11.5 Path No: 10 225 57.5 5.6 16.3 1 lx(us.Tee-Br)=3.56 1.13 100 8.5 0190 56.37 16.3 1.049 3.56 0.125 0.5 4.69 0.6 0190 9.6 Path No: 11 228 56.75 5.6 16.5 1 lx(us.90)=1.43 10.25 100 8.6 0181 56.41 16.5 1.049 1.43 0.1267 0.1 11.68 1.5 0181 10.3 Path No: 12 40 224 59.58 5.6 16.8 1 lx(us.90)=1.43 9.13 100 9 0186 56.37 16,8 1.049 1.43 0.1316 1.4 10.56 1.4 0186 56.37 16.9 1 lx(us.Tee-Br)=3.56 3.18 100 11.8 0164 56.35 33.7 1.049 3.56 0.4787 0.0 6,75 3.2 0164 15 Path No: 13 207 61 5.6 16.8 1 lx(us.Tee-Br)=3.56 4.62 100 9 0280 56.38 16.8 1.049 3.56 0.132 2 8.19 1.1 0280 12.1 Path No: 14 221 59.58 5.6 16.9 1 lx(us.Tee-Br)=3.56 4.35 100 9.1 0186 56.37 16.9 1.049 lx(us.90)=1.43 4.99 0.1336 1.4 9.34 1.2 0186 11.8 III File:C:\Users\lonnie\Documents\cromwell\72nd Ave Apts\72ND AVE(TIGARD 37)-WORKING FILE.dwg Date 12/5/2018 Copyright©2002-2012 Tyco Fire Protection Products Page 14 Job:72ND AVE APTS Hydraulic Calculations PIPE INFORMATION Node 1 Elev 1 K-Factor 1 Flow added (q) Nominal ID Fittings L C Factor total (Pt) Node 2 Elev 2 K-Factor 2 Total flow (Q) Actual ID quantity x (name) = length F Pf per ft elev (Pe) NOTES T frict(Pf) (ft) (gpm/psi1h) (gpm) (in) (ft) (ft) (psi) (psi) Path No: 15 210 56.5 5.6 17.2 1 lx(us.90)=1.43 8.08 100 9.4 0276 56.4 17.2 1.049 1.43 0.137 0.0 9.51 1.3 0276 56.4 17.9 1 10 100 10.7 0275 56.38 35 1.049 0 0.5129 0 10 5.1 0275 56.38 20.6 1.25 lx(us.Tee-Br)=4.28 1.5 100 15.9 0273 56.37 55.6 1.38 4.28 0.318 0 5.78 1.8 0273 56.37 21.4 4 8, 100 17.7 0272 56.34 77 4.26 0 0.0024 0.0 8 0.0 0272 56.34 20.6 4 3.32 100 17.8 0271 56.33 97.7 4.26 0 0.0037 0 3.32 0.0 0271 17.8 Path No: 16 227 56.83 5.6 17.5 1 lx(us.90)=1.43 8.33 100 9.7 0179 56.43 17.5 1.049 1.43 0.1414 0.2 till 9.76 1.4 0179 56.43 18.1 1 1x(us.Tee-Br)=3.56 3.18 100 11.3 0167 56.41 35.6 1.049 3.56 0.5291 0.0 6.75 3.6 0167 14.9 Path No: 17 204 61 5.6 17.6 1 lx(us.Tee-Br)=3.56 4.66 100 9.9 0282 56.34 17.6 1.049 3.56 0.1434 2 8.23 1.2 0282 13.1 Path No: 18 208 56.5 5.6 17.9 1 1x(us.Tee-Br)=3.56 0.1 100 10.2 0276 56.4 17.9 1.049 3.56 0.1473 0.0 3.67 0.5 0276 10.7 Path No: 19 220 56.83 5.6 18.1 1 1x(us.Tee-Br)=3.56 0.4 100 10.5 0179 56.43 18.1 1.049 3.56 0.1518 0.2 3.96 0.6 0179 11.3 • File:C:\Users\lonnie\Documents\cromwell\72nd Ave Apts\72ND AVE(TIGARD 37)-WORKING FILE.dwg Date 12/5/2018 Copyright©2002-2012 Tyco Fire Protection Products Page 15 Job: 72ND AVE APTS Hydraulic Calculations • PIPE INFORMATION Node 1 Elev 1 K Factor 1 Flow added (q) Nominal ID Fittings L C Factor total (Pt) Node 2 Elev 2 K-Factor 2 Total flow (Q) Actual ID quantity x (name) = length F Pf per ft elev (Pe) NOTES T frict(Pf) (ft) (gpm/psi1/2)_ (gpm) (in) (ft) (ft) (psi) (psi) Path No: 20 217 61 5.6 18.7 1 lx(us.Tee-Br)=3.56 7.27 100 11.1 0163 56.34 18.7 1.049 lx(us.90)=1.43 4.99 0.1597 2 12.26 2 0163 15.1 Path No: 21 215 57.5 5.6 18.7 1 lx(us.Tee-Br)=3.56 1.07 100 11.2 0174 56.43 18.7 1.049 3.56 0.1611 0.5 4.64 0.7 0174 12.4 Path No: 22 218 61 5.6 18.8 1 lx(us.Tee-Br)=3.56 7.27 100 11.3 0161 56.31 18.8 1.049 lx(us.90)=1.43 4.99 0.162 2 12.26 2 0161 15.3 Path No: 23 • 226 56.67 5.6 19.4 1 lx(us.Tee-Br)=3.56 11,35 100 11.9 0168 56.44 19.4 1.049 1x(us.90)=1.43 4.99 0.171 0.1 16.34 2.8 0168 56.44 40.4 4 8 100 14.8 0167 56.41 59.8 4.26 0 0.0015 0.0 8 0.0 0167 14.9 Path No: 24 223 57.42 5.6 19.8 1 lx(us.Tee-Br)=3.56 8.32 100 12.5 0160 56.29 19.8 1.049 lx(us.90)=1.43 4.99 0.179 0.5 13.31 2.4 0160 15.4 Path No: 25 214 56.67 5.6 20.1 1 lx(us.Tee-Br)=3.56 4.98 100 12.9 0169 56.46 20.1 1.049 lx(us.90)=1.43 4.99 0.1837 0.1 9.97 1.8 0169 56.46 20.3 4 4 100 14.8 0168 56.44 40.4 4.26 0 0.0007 0 4 0 0168 14.8 1 Path No: 26 121956.67 5.6 20.3 1 lx(us.Tee-Br)=3.56 3.35 100 13.2 0 .0169 56.46 20.3 1.049 lx(us.90)=1.43 4.99 0.1872 0.1 I 8.34 1.6 0169 14.8 I File:C:\Users\lonnie1 Documents\cromwell\72nd Ave Apts\72ND AVE(TIGARD 37)-WORKING FILE.dwg Date 12/5/2018 Copyright©2002-2012 Tyco Fire Protection Products Page 16 Job:72ND AVE APTS Hydraulic Calculations PIPE INFORMATION ° Node 1 Elev 1 K-Factor 1 Flow added (q) Nominal ID Fittings L C Factor total (Pt) Node 2 Elev 2 K-Factor 2 Total flow (Q) Actual ID quantity x (name) = length F Pf per ft elev (Pe) NOTES T frict(Pf) (ft) (gpm/psi1/2) (gpm) (in) (ft) (ft) (psi) (psi) Path No: 27 205 59 5.6 20.6 1 lx(us.Tee-Br)=3.56 2.62 100 13.6 0275 56.38 20.6 1.049 3.56 0.1923 1.1 6.19 1.2 0275 15.9 Path No: 28 206 61 5.6 20.6 1 1x(us.Tee-Br)=3.56 6.16 100 13.6 0272 56.34 20.6 1.0491x(us.90)=1.43 4.99 0.1927 2 11.15 2.1 0272 17.8 Path No: 29 203 57 5.6 21.4 1 1x(us.Tee-Br)=3.56 9.08 100 14.6 0273 56.37 21.4 1.049 lx(us.90)=1.43 4.99 0.2055 0.3 14.07 2.9 0273 17.7 Path No: 30 IH1 48.58 50 4 1x(coupling)=1.32 42.54 120 41.4 1315-0 11.67 50 4.26 1x(us.Tee-Br)=26.33 40.82 0.0008 16 • lx(us.90)=13.17 83.36 0.1 1315-0 11.67 0 4 0.39 0 57.5 VIC-705 1315-I 11.67 50 0 0 0.0104 0 *** 0.39 0 1315-I 11.67 0 4 1x(coupling)=1.32 143.45 120 57.5 0379-0 8.34 50 4.26 lx(us.Tee-Br)=26.33 132.99 0.0008 1.4 8x(us.90)=105.34 276.43 0.2 0379-0 8.34 0 4 1.59 0 59.2 GLOBE - UMC 0379-I 6.75 50 0 0 0.0331 0.7 MANIFOLD 1.59 0.1 *** 0379-I 6.75 0 4 lx(us.Tee-Br)=26.33 4.25 120 59.9 0021 2.5 50 4.26 26.33 0.0008 1.8 30.58 0.0 0021 61.8 Path No: 31 OH1 1 50 6 1x(us.Tee-Br)=51.84 15.5 140 80.9 0003 -4 50 6.4 2x(us.90)=48.39 100.23 0.0001 2.2 115.73 0 0003 83.1 III File:C:\Users\lonnie\Documents\cromwell\72nd Ave Apts\72ND AVE(TIGARD 37)-WORKING FILE.dwg Date 12/5/2018 Copyright©2002-2012 Tyco Fire Protection Products Page 17 Job:72ND AVE APTS Hydraulic Calculations PIPE INFORMATION Node 1 Elev 1 K-Factor 1 Flow added (q) Nominal ID Fittings L C Factor total (Pt) Node 2 Elev 2 K-Factor 2 Total flow (Q) Actual ID quantity x (name) = length F Pf per ft elev (Pe) NOTES T frict(Pf) (ft) (gpm/psis) (gpm) (in) (ft) (ft) (psi) (psi) * Pressures are balanced to a high degree of accuracy. Values may vary by 0.1 psi due to display rounding. * Maximum Velocity of 17.9 ft/s occurs in the following pipe(s): (0270-0282) *** Device pressure loss (gain in the case of pumps) is calculated from the device's curve. If the device curve is printed with this report, it will appear below. The length of the device as shown in the table above comes from the CAD drawing. The friction loss per unit of length is calculated based upon the length and the curve-based loss/gain value. Internal ID and C Factor values are irrelevant as the device is not represented as an addition to any pipe, but is an individual item whose loss/gain is based solely on the curve data. • • File:C:\Users\lonnie\Documents\cromwell\72nd Ave Apts\72ND AVE(TIGARD 37)-WORKING FILE.dwg Date 12/5/2018 Copyright©2002-2012 Tyco Fire Protection Products Page 18 Job:72ND AVE APTS Device Graphs Pressure vs. Flow Function Design Area: 2; Supply Ref.: W1; Supply Name:W1 1zs_ 120= n5- 110 105: 100. 90- 85= 80._ 71)Q 75 d 70..: L7 65.. N 55' d 50 45 10.: 35: 30- 25 20-= 15- I0.a 5- O O O O O O t O O O 0 Flow,gpm Pressure Loss Function S Design Area: 2; BFP Ref.: 1936 (AmesC300H, Size = 4); Inlet Node: 0012-I; Outlet Node: 0012-0 18.8= 17.8-- 16.8- 15 14.8: 13.8= 12.8= Olis - 9.7 psi@ 562 g pm w 10.8- -- L. N 9.8: 8.8 L a 78: 6.8 58.E 4.8 3.8 2 I.8- 0 8- Flow,gpm File:C:\Users\lonnie\Documents\cromwell\72nd Ave Apts\72ND AVE(TIGARD 37)-WORKING FILE.dwg Date 12/5/2018 Copyright©2002-2012 Tyco Fire Protection Products Page 19 Job:72ND AVE APTS Device Graphs Pressure Loss Function Design Area: 2; DPV Ref.: 1938 (NXT-768, Size = 4); Inlet Node: 0024-I; Outlet Node: 0024-0 24.094- 19.094- a • 14.094- a1 a 9.094- 4.094- 2.1 psi @ 512 gpm 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0kr, 0 0 On o 0 0 0 0 0 0 0 0 0 0 -- N N M M V � 00 o E- 0 co 0 N 0 0 00 Flow,gpm • Pressure Loss Function Design Area: 2; Valve Ref.: 1937 (VIC-705, Size = 4); Inlet Node: 0023-I; Outlet Node: 0023-0 20.197- 19.197r 18.197- 17.197- 16.197- 15.197-. 14.197- 13.197- 1/) CI. 12.197- i 11.197- u)• 10.197- U) CL 5.197-, 7.197= 6.197: 5.197- 4.197'- 3.197- 2.197= 0.4 psi @512 gpm 1.197.: 0.197- O O O O O O O O O O O O O O O O O O O O O O . — n _ O O O O O O O O O O O O N 0 C x O N N M Flow.gpm File:C:\Users\lonnie\Documents\cromwell\72nd Ave Apts\72ND AVE(TIGARD 37)-WORKING FILE.dwg Date 12/5/2018 Copyright©2002-2012 Tyco Fire Protection Products Page 20 Job:72ND AVE APTS Device Graphs Pressure Loss Function Design Area: 2; Valve Ref.: 1941 (GLOBE - UMC MANIFOLD, Size = 4); Inlet Node: 0379-1; Outlet Node: 0379-0. 6.7 5.7 •y 4.7... O. ElL to 3.7.-. ....... to 2 i a 2.7- 1.7.. 0.7-- 0.1 psi @ 50 gpm : o o 0 O o 00 n 0, 9._. x ON d _ --5Flow,gpm Pressure Loss Function • Design Area: 2; Valve Ref.: 1947 (VIC-705, Size = 4); Inlet Node: 1315-I; Outlet Node: 1315-0 20.197 (9.197, 344_4_, 4.__. . 1 i ek t 1 F i 1 i 18.197= -.f 1 _.� .4_ _4'... _ a 55 5 on. .... i i 17.197- 41 tf ! 244' .._ _ ._._._. 3 5 1 16.197. $ ..� _ i r i - k f t 1 e 4 i t 15.197, i _ 1 . 1 T 3 ...�i -.,..__..---"i' _.. 1 1 { 4 1 - 1 I j 1 14.1972 . d r __ �_ #ry -�._ _ f _— it '.m""'.' ; "_-" _ _ I3 I Q. 12.197- dY 4 ---t-----2 -!-- - is i._._ _ i1--i—÷-14----r--_.. - N10.197- ___f___. ..;w __t-._._i _..._.1..r.v:®, t _t....._. - .a.._- __ __ .:. -- 4 i 9.197- 1 S {f_ I 3 1 l ; _... a f 1 8.197- _ ....4 ,_.r�. ,. ...._.. ._ 1-- ! '(-..��,.. ----j .. .4._.� ....,13.1.3.,,... N.. 1 , 7.]97 S 1 - _ ,4 t I { 6.197- $— i1 i I r 1 4 1 5.197.. -----------1-�`. } :.. ._.m...L._....._..m...._.._..._. a... r...._.. .®.e...,... .�...._.. 1 1 1 + 4.197: _m 4.H___.1 a, y 1 __ S ..1....._4_ 1.__. I ___,1 _._ 3.197-- .._.�..._ 1 2.197-_ 0P si @ 50 9P m .._ 1397' ,..3-4-3.4.434.434.4*---, 0197 6 o 0 0 0 o 0 0 0 0 0 0 0 0 o o o o _ O O 9 o 0 0 0 O o 0 O o 0 o O - -- N N M M 7 o t-- OC a o N R o W o N so f l v Flow,gpm1111/ File:C:\Users\lonnie\Documents\cromwell\72nd Ave Apts\72ND AVE(TIGARD 37)-WORKING FILE.dwg Date 12/5/2018 Copyright©2002-2012 Tyco Fire Protection Products Page 21 • • • CALCULATION SUMMARY Project Name:72ND AVE APTS Project Location: 11740 SW 72ND AVE Drawing No.: City: TIGARD, OREGON Design Areas Design Area Calc. Mode Occupancy Area of Total Water Pressure @ Min. Min. Min. Calculated Hose Margin To Name (Model) Application Source Density Pressure Flow Heads Streams Source (ft2) (gpm) (psi) (gpm/ft2) (psi) (gpm) # (gpm) (psi) 3 Demand(HW) OHI 1967 804.5 Required 0.15 12.1 19.5 20 250 22.1 85.1 File:C:\Users\lonnie\Documents\Cromwell\72nd Ave Apts\72ND AVE(TIGARD 37)-WORKING FILE.dwg Date 12/5/2018 Copyright©2002-2012 Tyco Fire Protection Products Page 1 HYDRAULIC CALCULATIONS for Job Information • Project Name:72ND AVE APTS Contract No.: City: TIGARD, OREGON Project Location: 11740 SW 72ND AVE Date: 11/13/2018 Contractor Information Name of Contractor: CROMWELL FIRE Address: 25599 SW 95TH AVE City: WILSONVILLE, OREGON 97070 Phone Number: 971-224-5304 E-mail:lonniel@cromwellinc.com Name of Designer: LONNIE LARSEN Authority Having Jurisdiction: TBD Design Remote Area Name 3 Remote Area Location PARKING-DRY Occupancy Classification OHI Aor Density(gpm/ft2) 0.15 � AKA, Area of Application(ft2) 1967 `' 77506 PE Coverage per Sprinkler(ftZ) 130 12-21 -2018 OREGON • Number of Calculated Sprinklers 20 v v9- �rO 10 ti In-Rack Demand(gpm) 0 'PIP} L . 0.\'‘C Special Heads EXPIRATION DATE:12/31/20 Hose Streams(gpm) 250 Total Water Required(incl. Hose Streams)(gpm) 804.5 Required Pressure at Source(psi) 85.1 Type of System Dry Volume-Downstream DPV (gal) 468.3 gal Water Supply Information Date 7/17/2018 Location SW 72ND AVE&SW CLINTON ST Source W1 Notes 0.15GPM/FT2 @ 130FT2 PER HEAD • File:C:\Users\lonnie\Documents\cromwell\72nd Ave Apts\72ND AVE(TIGARD 37)-WORKING FILE.dwg Date 12/5/2018 Copyright©2002-2012 Tyco Fire Protection Products Page 2 • • Job:72ND AVE APTS Node Labels: Off Pipe Labels: Off Diagram for Design Area : 3 (Ootimized Hydraulic Simalifiedl Yom., File:C:\Usersllonnie\Documents\cromwell\72nd Ave Apts\72ND AVE(TIGARD 37)-WORKING FILE.dwg Date 12/5/2018 Copyright©2002-2012 Tyco Fire Protection Products Page 3 Job:72ND AVE APTS Hydraulic Analysis for : 3 Calculation Info • Calculation Mode Demand Hydraulic Model Hazen-Williams Fluid Name Water @ 60F (15.6C) Fluid Weight, (Ib/ft3) N/A for Hazen-Williams calculation. Fluid Dynamic Viscosity, (lb•s/ft2) N/A for Hazen-Williams calculation. Water Supply Parameters Supply 1 :W1 Flow(gpm) Pressure(psi) 0 110 2293 91 5312 20 Supply Analysis Residual Available Static Pressure Flow Total Demand Required Pressure Node at Source Pressure Pressure (psi) (psi) (gpm) (psi) (gpm) (psi) W1 110 91 2293 107.3 804.5 85.1 Hoses Inside Hose Flow/Standpipe Demand(gpm) 100 Outside Hose Flow(gpm) 150 Additional Outside Hose Flow(gpm) Other(custom defined) Hose Flow(gpm) 0 • Total Hose Flow(gpm) 250 Sprinklers Ovehead Sprinkler Flow(gpm) 554.5 InRack Sprinkler Flow(gpm) 0 Other(custom defined)Sprinkler Flow(gpm) 0 Total Sprinkler Flow(gpm) 554.5 Other Required Margin of Safety(psi) 0 W1 -Pressure(psi) 85.1 W1 -Flow(gpm) 804.5 Demand w/o System Pump(s) N/A • File:C:\Users\lonnie\Documents\cromwell\72nd Ave Apts\72ND AVE(TIGARD 37)-WORKING FILE.dwg Date 12/5/2018 Copyright©2002-2012 Tyco Fire Protection Products Page 4 • • • Job:72ND AVE APTS Hydraulic Analysis for : 3 S. System Demand 0 Available At Source 150 140 130 107.3 psi @804.5 gpm 110- I 100. S2 90 D2 to ac 80 \ W (I)1 70 a \60 50 40 30 mS3. 20 D1 -2.752 0 2000 2500 3000 3500 4000 4500 5000 5500 8000 Flow,gpm File:C:\Users\lonnie\Documents\cromwell\72nd Ave Apts\72ND AVE(TIGARD 37)-WORKING FILE.dwg Date 12/5/2018 Copyright©2002-2012 Tyco Fire Protection Products Page 5 Job:72ND AVE APTS Hydraulic Analysis for : 3 • Graph Labels Values Label Description Flow (gpm) Pressure (psi) S1 Supply point#1 -Static 0 110 S2 Supply point#2 2293 91 S3 Supply point#3 5312 20 D1 Elevation Pressure 0 4.6 D2 System Demand 804.5 85.1 Curve Intersections & Safety Margins Intersection Safety Margin Curve Name Pressure (psi) Flow (gpm) Pressure (psi) @ Flow (gpm) Supply 106.5 913.7 22.1 804.5 Open Heads Required Calculated Head Ref. Head Type Coverage K-Factor Density Flow Pressure Density Flow Pressure (ft2) (gpm/Psi'/2) (gpm/ft2) (gpm) (Psi) (gpm/ft2) (gpm) (psi) 301 Overhead 130 5.6 0.15 19.5 12.1 0.215 27.9 24.9 Sprinkler 302 Overhead 130 5.6 0.15 19.5 12.1 0.225 29.3 27.4 41111 Sprinkler 303 Overhead 130 5.6 0.15 19.5 12.1 0.235 30.6 29.8 Sprinkler 304 Overhead 130 5.6 0.15 19.5 12.1 0.235 30.6 29.8 Sprinkler 305 Overhead 130 5.6 0.15 19.5 12.1 0.225 29.3 27.4 Sprinkler 306 Overhead 130 5.6 0.15 19.5 12.1 0.215 27.9 24.9 Sprinkler 307 Overhead 130 -5;6 0.15 19.5 12.1 0.215 28 24.9 Sprinkler 308 Overhead 130 5.6 0.15 19.5 12.1 0.226 29.3 27.4 Sprinkler 309 Overhead 130 5.6 0.15 19.5 12.1 0.236 30.6 29.9 Sprinkler 310 Overhead 130 5.6 0.15 19.5 12.1 0.236 30.6 29.9 Sprinkler 311 Overhead 130 5.6 0.15 19.5 12.1 0.226 29.3 27.4 Sprinkler 312 Overhead 130 5.6 0.15 19.5 12.1 0.215 28 24.9 Sprinkler 313 Overhead 130 5.6 0.15 19.5 12.1 0.159 20.6 13.6 4110 Sprinkler File:C:\Users\lonnie\Documents\cromwell\72nd Ave Apts\72ND AVE(TIGARD 37)-WORKING FILE.dwg Date 12/5/2018 Copyright©2002-2012 Tyco Fire Protection Products Page 6 314 Overhead 130 5.6 0.15 19.5 12.1 0.15 19.5 12.1 Sprinkler • 315 Overhead Sprinkler 130 5.6 0.15 19.5 12.1 0.217 28.2 25.3 316 Overhead 130 5.6 0.15 19.5 12.1 0.227 29.5 27.8 Sprinkler 317 Overhead 130 5.6 0.15 19.5 12.1 0.237 30.8 30.3 Sprinkler 318 Overhead 130 5.6 0.15 19.5 12.1 0.212 27.6 24.2 Sprinkler 319 Overhead 130 5.6 0.15 19.5 12.1 0.187 24.3 18.9 Sprinkler 320 Overhead 130 5.6 0.15 19.5 12.1 0.172 22.4 16 Sprinkler • • File:C:\Users\lonnie\Documents\cromwell\72nd Ave Apts\72ND AVE(TIGARD 37)-WORKING FILE.dwg Date 12/5/2018 Copyright©2002-2012 Tyco Fire Protection Products Page 7 Job:72ND AVE APTS Hydraulic Calculations I Fluid Delivery Time Analysis Node Data Node# Type K-Fact. Discharge Coverage Tot. Pres. Req. Pres. • Elev Hgroup Open/Closed Overdischarge Density Elev. Pres. Req. Discharge ft gpm/psis/z gpm ft2 psi psi gpm gpm/ft2 psi gpm 314 Overhead Sprinkler 5.6 19.5 130 12.1 12.1 11.58 HEAD Open 0 0.15 -4.6 19.5 313 Overhead Sprinkler 5.6 20.6 130 13.6 12.1 11.56 HEAD Open 1.1 0.159 -4.6 19.5 320 Overhead Sprinkler 5.6 22.4 130 16 12.1 11.52 HEAD Open 2.9 0.172 -4.6 19.5 319 Overhead Sprinkler 5.6 24.3 130 18.9 12.1 11.48 HEAD Open 4.8 0.187 -4.5 19.5 318 Overhead Sprinkler 5.6 27.6 130 24.2 12.1 11.44 HEAD Open 8.1 0.212 -4.5 19.5 306 Overhead Sprinkler 5.6 27.9 130 24.9 12.1 11.5 HEAD Open 8.4 0.215 -4.6 19.5 301 Overhead Sprinkler 5.6 27.9 130 24.9 12.1 11.5 HEAD Open 8.4 0.215 -4.6 19.5 307 Overhead Sprinkler 5.6 28 130 24.9 12.1 11.5 HEAD Open 8.5 0.215 -4.6 19.5 312 Overhead Sprinkler 5.6 28 130 24.9 12.1 11.5 HEAD Open 8.5 0.215 -4.6 19.5 315 Overhead Sprinkler 5.6 28.2 130 25.3 12.1 11.5 HEAD Open 8.7 0.217 -4.6 19.5 302 Overhead Sprinkler 5.6 29.3 130 27.4 12.1 11.47 HEAD Open 9.8 0.225 -4.5 19.5 305 Overhead Sprinkler 5.6 29.3 130 27.4 12.1 III 11.47 HEAD Open 9.8 0.225 -4.5 19.5 308 Overhead Sprinkler 5.6 29.3 130 27.4 12.1 11.47 HEAD Open 9.8 0.226 -4.5 19.5 311 Overhead Sprinkler 5.6 29.3 130 27.4 12.1 11.47 HEAD Open 9.8 0.226 -4.5 19.5 316 Overhead Sprinkler 5.6 29.5 130 27.8 12.1 11.47 HEAD Open 10 0.227 -4.5 19.5 303 Overhead Sprinkler 5.6 30.6 130 29.8 12.1 11.43 HEAD Open 11.1 0.235 -4.5 19.5 304 Overhead Sprinkler 5.6 30.6 130 29.8 12.1 11.43 HEAD Open 11.1 0.235 -4.5 19.5 309 Overhead Sprinkler 5.6 30.6 130 29.9 12.1 11.43 HEAD Open 11.1 0.236 -4.5 19.5 310 Overhead Sprinkler 5.6 30.6 130 29.9 12.1 11.43 HEAD Open 11.1 0.236 -4.5 19.5 317 Overhead Sprinkler 5.6 30.8 130 30.3 12.1 11.43 HEAD Open 11.3 0.237 -4.5 19.5 0046 Node 40.1 10.49 NODE -4.1 0045 Node 40.3 10.42 NODE -4.1 0044 Node 40.9 10.35 NODE -4.1 0024-0 Node 53 6.75 NODE -2.5 1316 Node 54 • 11.67 NODE -4.6 File:C:\Users\lonnie\Documents\cromwell\72nd Ave Apts\72ND AVE(TIGARD 37)-WORKING FILE.dwg Date 12/5/2018 Copyright©2002-2012 Tyco Fire Protection Products Page 8 Job:72ND AVE APTS Hydraulic Calculations/Fluid Delivery Time Analysis • Node Data Node# Type K-Fact. Discharge Coverage Tot. Pres. Req. Pres. Elev Hgroup Open/Closed Overdischarge Density Elev. Pres. Req. Discharge 9Pm/Psis/z gpm ft2 psi psi ft gpm gpm/ft2 psi gpm 1315-0 Node 54.1 11.67 NODE -4.6 1315-I Node 54.1 11.67 NODE -4.6 0024-I Node 56 5.5 NODE -1.9 0379-0 Node 56.3 8.34 NODE -3.2 IH2 Inside Hose 100 56.5 3.5 HOSE -1.1 100 0023-0 Node 56.9 3.88 NODE -1.2 0379-I Node 57.1 6.75 NODE -2.5 0023-I Node 57.5 3.5 NODE -1.1 0021 Node 59 2.5 NODE -0.6 0015 Node 67.8 -4 NODE 2.2 0012-0 Node 72.5 -4 NODE 2.2 OH1 Outside Hose 150 83.9 1 HOSE 0 150 0012-I Node 85.1 -4 NODE 2.2 W1 Supply 85.1 1 SUPPLY 804.5 0 0010 Node 86.1 -4 NODE 2.2 0003 Node 86.1 -4 NODE 2.2 0004 Node 86.4 -4 NODE 2.2 0005 Node 86.5 -4 NODE 2.2 • File:C:\Users\lonnie\Documents\cromwell\72nd Ave Apts\72ND AVE(TIGARD 37)-WORKING FILE.dwg Date 12/5/2018 Copyright©2002-2012 Tyco Fire Protection Products Page 9 Job:72ND AVE APTS Hydraulic Calculations PIPE INFORMATION Node 1 Elev 1 K-Factor 1 Flow added (q) Nominal ID Fittings L C Factor total (Pt) Node 2 Elev 2 K-Factor 2 Total flow (Q) Actual ID quantity x (name) = length F Pf per ft elev (Pe) NOTES T frict(Pf) (ft) (gpm/Psis/z) (gpm) (in) (ft) (ft) (psi) (psi) Path No: 1 314 11.58 5.6 19.5 1 8.33 100 12.1 313 11.56 5.6 19.5 1.049 0 0.1734 0.0 8.33 1.4 313 11.56 5.6 20.6 1.25 2x(us.90)=4.28 9.33 100 13.6 320 11.52 5.6 40.1 1.38 4.28 0.1737 0.0 13.61 2.4 320 11.52 5.6 22.4 1.25 7.33 100 16 319 11.48 5.6 62.5 1.38 0 0.3945 0.0 7.33 2.9 319 11.48 5.6 24.3 1.25 7.33 100 18.9 318 11.44 5.6 86.8 1.38 0 0.7252 0.0 7.33 5.3 318 11.44 5.6 27.6 1.25 1x(us.Tee-Br)=4.28 4.85 100 24.2 0044 10.35 114.4 1.38 2x(us.90)=4.28 8.56 1.2081 0.5 13.4 16.2 0044 10.35 440.1 4 lx(coupling)=0.94 84.27 100 40.9 0024-0 6.75 554.5 4.26 lx(us.90)=9.39 29.1 0.0928 1.6 lx(us.Tee-Br)=18.78 113.37 10.5 0024-0 6.75 0 4 1.25 0 53 NXT-768 0024-I 5.5 554.5 0 0 2.0079 0.5 *** 1.25 2.5 0024-I 5.5 0 4 1x(coupling)=1.32 1.63 120 56 411 0023-0 3.88 554.5 4.26 1.32 0.0662 0.7 2.94 0.2 0023-0 3.88 0 4 0.38 0 56.9 VIC-705 0023-I 3.5 554.5 0 0 1.2244 0.2 *** 0.38 0.5 0023-I 3.5 0 4 lx(us.90)=13.17 2.67 120 57.5 0021 2.5 554.5 4.26 13.17 0.0662 0.4 15.83 1 0021 2.5 100 4 3x(us.90)=39.5 16.25 120 59 0015 -4 654.5 4.26 2x(us.45)=10.53 50.03 0.09 2.8 66.29 6 0015 -4 0 4 lx(coupling)=1.83 52.76 140 67.8 0012-0 -4 654.5 4.3 1x(us.90)=18.33 20.16 0.0646 0 72.92 4.7 0012-0 -4 0 4 2.81 0 72.5 AmesC300H 0012-I -4 654.5 0 0 4.4927 0 *** 2.81 12.6 0012-I -4 0 4 lx(coupling)=1.83 13.35 140 85.1 0010 -4 654.5 4.3 1.83 0.0646 0 15.18 1 0010 -4 0 8 1 140 86.1 0003 -4 654.5 8.55 0 0.0023 0 1 0 0003 -4 150 8 1x(us.Tee-Br)=61.64 23.29 140 86.1 0004 -4 804.5 8.55 61.64 0.0033 0 84.92 0.3 • File:C:\Users\lonnie\Documents\cromwell\72nd Ave Apts\72ND AVE(TIGARD 37)-WORKING FILE.dwg Date 12/5/2018 Copyright©2002-2012 Tyco Fire Protection Products Page 10 Job:72ND AVE APTS Hydraulic Calculations • PIPE INFORMATION Node 1 Elev 1 K-Factor 1 Flow added (q) Nominal ID Fittings L C Factor total (Pt) Node 2 Elev 2 K-Factor 2 Total flow (Q) Actual ID quantity x (name) = length F Pf per ft elev (Pe) NOTES T frict(Pf) (ft) (gpm/psi1/2) (gpm) (in) (ft) (ft) (psi) (psi) Path No: 1 0004 -4 0 12 lx(us.Tee-Br)=99.1 120 140 86.4 0005 -4 804.5 12.64 99.1 0.0005 0 219.1 0.1 0005 -4 0 6 2x(us.90)=48.39 11.5 140 86.5 1 W1 1 804.5 6.4 48.39 0.0137 -2.2 59.89 0.8 W1 85.1 Path No: 2 306 11.5 5.6 27.9 1 7.33 100 24.9 305 11.47 5.6 27.9 1.049 0 0.3374 0.0 7.33 2.5 305 11.47 5.6 29.3 1.25 7.33 100 27.4 304 11.43 5.6 57.2 1.38 0 0.335 0.0 7.33 2.5 304 11.43 5.6 30.6 1.25 lx(us.Tee-Br)=4.28 4.72 100 29.8 0046 10.49 87.8 1.38 2x(us.90)=4.28 8.56 0.7404 0.4 13.27 9.8 400046 10.49 87.8 4 14.5 100 40.1 0045 10.42 175.6 4.26 0 0.011 0.0 14.5 0.2 0045 10.42 175.9 4 14.5 100 40.3 0044 10.35 351.5 4.26 0 0.0399 0.0 14.5 0.6 0044 40.9 Path No: 3 301 11.5 5.6 27.9 1 7.33 100 24.9 302 11.47 5.6 27.9 1.049 0 0.3374 0.0 7.33 2.5 302 11.47 5.6 29.3 1.25 7.33 100 27.4 303 11.43 5.6 57.2 1.38 0 0.335 0.0 7.33 2.5 303 11.43 5.6 30.6 1.25 1x(us.Tee-Br)=4.28 4.72 100 29.8 0046 10.49 87.8 1.38 2x(us.90)=4.28 8.56 0.7404 0.4 13.27 9.8 0046 40.1 • File:C:\Users\lonnie\Documents\cromwell\72nd Ave Apts\72ND AVE(TIGARD 37)-WORKING FILE.dwg Date 12/5/2018 Copyright©2002-2012 Tyco Fire Protection Products Page 11 Job:72ND AVE APTS Hydraulic Calculations PIPE INFORMATION Node 1 Elev 1 K-Factor 1 Flow added (q) Nominal ID Fittings L C Factor total (Pt) Node 2 Elev 2 K-Factor 2 Total flow (Q) Actual ID quantity x (name) = length F Pf per ft elev (Pe) NOTES T frict(Pf) (ft) (gpm/psi1/2) (gpm) (in) (ft) (ft) (psi) (psi) Path No: 4 312 11.5 5.6 28 1 7.33 100 24.9 311 11.47 5.6 28 1.049 0 0.3383 0.0 7.33 2.5 311 11.47 5.6 29.3 1.25 7.33 100 27.4 310 11.43 5.6 57.3 1.38 0 0.3359 0.0 7.33 2.5 310 11.43 5.6 30.6 1.25 lx(us.Tee-Br)=4.28 4.78 100 29.9 0045 10.42 87.9 1.38 2x(us.90)=4.28 8.56 0.7424 0.4 13.34 9.9 0045 40.3 Path No: 5 307 11.5 5.6 28 1 7.33 100 24.9 308 11.47 5.6 28 1.049 0 0.3383 0.0 7.33 2.5 308 11.47 5.6 29.3 1.25 7.33 100 27.4 309 11.43 5.6 57.3 1.38 0 0.3359 0.0 7.33 2.5 309 11.43 5.6 30.6 1.25 lx(us.Tee-Br)=4.28 4.78 100 29.9 0045 10.42 87.9 1.38 2x(us.90)=4.28 8.56 0.7424 0.4 13.34 9.9III 0045 40.3 Path No: 6 315 11.5 5.6 28.2 1 7.33 100 25.3 316 11.47 5.6 28.2 1.049 0 0.3426 0.0 7.33 2.5 316 11.47 5.6 29.5 1.25 7.33 100 27.8 317 11.43 5.6 57.7 1.38 0 0.3401 0.0 7.33 2.5 317 11.43 5.6 30.8 1.25 lx(us.Tee-Br)=4.28 4.85 100 30.3 0044 10.35 88.5 1.38 2x(us.90)=4.28 8.56 0.7517 0.5 13.4 10.1 0044 40.9 • File:C:\Users\lonnie\Documents\cromwell\72nd Ave Apts\72ND AVE(TIGARD 37)-WORKING FILE.dwg Date 12/5/2018 Copyright©2002-2012 Tyco Fire Protection Products Page 12 Job:72ND AVE APTS Hydraulic Calculations • PIPE INFORMATION Node 1 Elev 1 K-Factor 1 Flow added (q) Nominal ID Fittings L C Factor total (Pt) Node 2 Elev 2 K-Factor 2 Total flow (Q) Actual ID quantity x (name) = length F Pf per ft elev (Pe) NOTES T frict(Pf) (ft) (gpm/Psi12) (gpm) (in) (ft) (ft) (Psi) (psi) Path No: 7 IH2 3.5 100 2.5 lx(us.Tee-Br)=12 9.96 120 56.5 1316 11.67 100 2.469 lx(us.90)=6 18 0.0395 -3.5 27.96 1.1 1316 11.67 0 4 lx(coupling)=1.32 3.86 120 54 1315-0 11.67 100 4.26 1.32 0.0028 0 5.18 0.0 1315-0 11.67 0 4 0.39 0 54.1 VIC-705 1315-I 11.67 100 0 0 0.0259 0 *** 0.39 0.0 1315-I 11.67 0 4 lx(coupling)=1.32 143.45 120 54.1 0379-0 8.34 100 4.26 lx(us.Tee-Br)=26.33 132.99 0.0028 1.4 8x(us.90)=105.34 276.43 0.8 0379-0 8.34 0 4 1.59 0 56.3 GLOBE - UMC 0379-I 6.75 100 0 0 0.0694 0.7 MANIFOLD 1.59 0.1 *** 0379-I 6.75 0 4 1x(us.Tee-Br)=26.33 4.25 120 57.1 0021 2.5 100 4.26 26.33 0.0028 1.8 30.58 0.1 0021 59 5 Path No: 8 OH1 1 150 6 lx(us.Tee-Br)=51.84 15.5 140 83.9 0003 -4 150 6.4 2x(us.90)=48.39 100.23 0.0006 2.2 115.73 0.1 0003 86.1 * Pressures are balanced to a high degree of accuracy. Values may vary by 0.1 psi due to display rounding. * Maximum Velocity of 24.54 ft/s occurs in the following pipe(s): (0044-318) *** Device pressure loss (gain in the case of pumps) is calculated from the device's curve. If the device curve is printed with this report, it will appear below. The length of the device as shown in the table above comes from the CAD drawing. The friction loss per unit of length is calculated based upon the length and the curve-based loss/gain value. Internal ID and C Factor values are irrelevant as the device is not represented as an addition to any pipe, but is an individual item whose loss/gain is based solely on the curve data. S File:C:\Users\lonnie\Documents\cromwell\72nd Ave Apts\72ND AVE(TIGARD 37)-WORKING FILE.dwg Date 12/5/2018 Copyright©2002-2012 Tyco Fire Protection Products Page 13 Job:72ND AVE APTS Device Graphs Pressure vs. Flow Function Design Area: 3; Supply Ref.:W1; Supply Name:W1 • 125__ 1201 115= II0 105- l00.: 95 90-= 85 80- G. 75. 70. 3 65 M 60 ` 55;: 50 is 45 40= 35.[ 30.- 25 20 15-- 10 5 0 0 0 0 0 0 0 0 0 0 N c 0 0 0 0 0 0 0 c Flow,gpm Pressure Loss Function S Design Area: 3; BFP Ref.: 1936 (AmesC300H, Size = 4); Inlet Node: 0012-1; Outlet Node: 0012-0 18.8- 17.8- 16.8 15.& 14.8.- 13.5 . 12.6 psi @6545gpm 12.8 u.8 c 10.8, 9.8 a- 7s' 5.8_ 4 8 3.8,: Lg..: 0 0 c o c o c c o v o 0 0 o c o Flow,gpm • File:C:\Users\lonnie\Documents\cromwell\72nd Ave Apts\72ND AVE(TIGARD 37)-WORKING FILE.dwg Date 12/5/2018 Copyright©2002-2012 Tyco Fire Protection Products Page 14 Job:72ND AVE APTS Device Graphs Pressure Loss Function • Design Area: 3; DPV Ref.: 1938 (NXT-768, Size = 4); Inlet Node: 0024-I; Outlet Node: 0024-0 24.094- 19.094- fa 4.09419.094- y 14.094-- a) I- 9.094- 2.5 psi @554.5gpm € 4.094_ a O O O O O OO O O O 0 O O O O O O O O O O 0 O O O O O O O O O O x — N N M . . 7 y' V1 00 R o0 0 0 0 0 0 Flow,gpm - - - - 411 Pressure Loss Function Design Area: 3; Valve Ref.: 1937 (VIC-705, Size = 4); Inlet Node: 0023-I; Outlet Node: 0023-0 20.197.. . 19.197.. 18.197- 17.197- 16,197- 15.197- 4.197= 13.197., N 4. 12.197 d 11.197 3 U) 10.197- U) i 9.197.: 8.197- 7.197- 6.197 5.197- 4.197- 3.197- 2.197 .1974.197_3.197-2.197 0.5 psi @554.5 gpm' 1.197.: 0.197- O— OO O O O O O O O O 410 O, O O O O O O O O OO OO OO OO t> 'S O N 7 C 00 O N 0U N �D Flow,gpm File:C:\Users\lonnie\Documents\cromwell\72nd Ave Apts\72ND AVE(TIGARD 37)-WORKING FILE.dwg Date 12/5/2018 Copyright©2002-2012 Tyco Fire Protection Products Page 15 Job:72ND AVE APTS Device Graphs Pressure Loss Function Design Area: 3; Valve Ref.: 1941 (GLOBE - UMC MANIFOLD, Size = 4); Inlet Node: 0379-I; Outlet Node: 0379-0. 6.7- 5.7 •N 4.7_ 0. d N d 1 CL 2.7- 1.7-- 0.7 .7- 1.7_0.7 _ 0.1 psi @100gpm 0 0 0 0 0 o 0 0 0 0 o 0 0 0 00 0 x 0 Flow,gpm Pressure Loss Function 11111/ Design Area: 3; Valve Ref.: 1947 (VIC-705, Size = 4); Inlet Node: 1315-I; Outlet Node: 1315-0 20.197.'. 19.197- 18.197- 17.197- 16.197-. 14.197- 13.197.: N Q. 12.1977 m 11.197- N 10.197.: In d 9.197. 8.197. 7.197 6.]97.'.. 5.197- 4.197; 3.197_ 2.197.. 0.0 psi@ 100 gpm 1.197 0.197: O O O O O O 0 — O — O 0 O O O O O O O O 00 O C 00 00 O O O O O O O O O O O O O 00 00 00 00 a x c O N V �O x O V N N G Flow,gpm^ • File:C:\Users\lonnie\Documents\cromwell\72nd Ave Apts\72ND AVE(TIGARD 37)-WORKING FILE.dwg Date 12/5/2018 Copyright©2002-2012 Tyco Fire Protection Products Page 16 • CROMWELL FIRE SYSTEMS 25599 SW 59TH AVENUE; WILSONVILLE, OREGON 97070 PHONE: (971)-224-5304 FAX: (971)-224-5313 OREGON CCB 44712 CROMWELL , FIRE .�, ..�. ► (' 'P vl 77506 PE • 12-14-2018 72ND AVE APARTMENTS OREGONco 11740 SW 72ND AVENUE, «)i, /0 0^ L . TIGARD, OREGON EXPIRATION DATE:12/31/18 FIRE PROTECTION EQUIPMENT SUBMITTALS • HARBOR SKY 1055 N. HARBOR WAY PORTLAND, OREGON 97217 FIRE PROTECTION EQUIPMENT SUBMITTAL INDEX PRODUCT MAKE MODEL/DISCRIPTION 1. SPRINKLERS VICTAULIC MODEL V27 RESIDENTAL WHITE SIN#2740 SEMI-RECESSED PENDANT 4.9K VICTAULIC MODEL V27 QR WHITE PENDANT SIN#2708 SEMI-RECESSED 5.6K VICTAULIC MODEL V27 QR WHITE HSW SIN#2710 SEMI-RECESSED 5.6K VICTAULIC MODEL V36 QR CHROME HSW SIN #3610 DRY SLV/SKT 5.6K VICTAULIC MODEL V27 QR BRASS UPR SIN#2704 EXP. 5.6K TYCO SERIES CC3 COMBUSTIBLE CONCEALED SPACE SPRINKLERS 5.6K BRASS UPR (TY3199) • 2. PIPE BULLMOOSE TUBE BLACK STEEL, EDDYFLOW ASTM A795 & A135 BULLMOOSE TUBE BLACK STEEL, SCHEDULE 10,ASTM A795 & A135 BULLMOOSE TUBE BLACK STEEL, EDDYTHREAD 40,A795& A135 BULLMOOSE TUBE BLACK STEE, SCHEDULE 40,A795 &A135 SPEARS FLAMEGUARD CPVC,ASTM F442. SDR 13.5 3. PIPE FITTINGS BLAZEMASTER FLAMEGUARD CPVC,ASTM F438 & F439 VICTAULIC FIRELOCK SHORT TURN GROOVED DUCTILE IRON FITTINGS ASTM A536 VICTAULIC FIRELOCK#009 COUPLINGS DUCTILE IRON ASTM A536,ASTM A 395 SMITH COOPER CAST IRON,THREADED,ASTM A126 SMITH COOPER DUCTILE RON,THREADED,ASTM A536 • • 4. HANGERS AFCON MODEL 510 HANGER AFCON MODEL 511 HANGER AFCON MODEL 513 HANGER AFCON MODEL 514 HANGER AFCON MODEL 515 HANGER AFCON MODEL 519 HANGER AFCON MODEL 300 RING HANGER TOLCO FIGURE 2NFPA HANGER RING TOLCO FIGURE ATR ALL THREAD ROD SAMMY FASTENERS FOR WOOD 5. SEISMIC EQUIP AFCON SWAY BRACE FITTING 411 AFCON SWAY BRACE FITTING MODEL E AFCON ATTACHMENT FITTING LOCKING 077 AFCON RISER CLAMP 400 6. VALVES VICTAULIC FIRELOCK STYLE 705 BFV VICTAULIC FIRELOCK STYLE 717 CHECK FPPI FPPI CHAECK VALVE • FPPI FPPI FULL FLOATING CLAPPER ASSSEMBLY (SWING CHECK) FPPI THREE-WAY BRASS VALVE GLOBE UMC UNIVERSAL MANIFOLD CHECK ASSEMBLY VICTAULIC FIRELOCK NXT-768 VICTAULIC FIRELOCK AIR MAINTANCE 757 C-AIRE C-AIRE RISER MOUNTED COMPRESSOR 261 R-LD1-115PD CROKER FIRE DEPT INLET CONN EXPOSED TYPE CROKER ANGLE FIRE HOSE VALVE 7. ELEC POTTER MODEL VSR WATERFLOW SWITCH POTTER PS10 SERIES PRESSURE SWITCH POTTER PS40 SERIES PRESSURE SWITCH POTTER MODEL PBA 6" ELECTRIC BELL 8. MISCELLANEOUS FPPI IDENTIFICATION SIGNS FPPI SPARE SPRINKLER CABINET FPPI 300#GAUGE • A I I �=R ®B. SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS Residential Pendent and Recessed Pendent V2740 QUICK RESPONSE This Model V27 residential sprinkler is designed to meet the requirements of NFPA 13, 13D 4: and 13R for residential use in a variety of room sizes,depending upon available operating pressure and room configuration.The design incorporates state-of-the-art,heat responsive, frangible glass bulb design(quick response)for prompt,precise operation. sit The die cast frame is more streamlined and attractive than traditional sand cast frames. It is cast with a hex-shaped wrench boss to allow easy tightening from many angles, reducing assembly effort.This sprinkler is available in various finishes to meet many design PENDENT requirements. (V2740) SPRINKLER OPERATION: The operating mechanism is a frangible glass bulb which contains a heat responsive liquid.During a fire,the ambient temperature rises causing the liquid in the bulb to expand.When the ambient temperature reaches the rated temperature of the sprinkler,the bulb shatters.As a result,the waterway is cleared of all sealing parts and water is discharged towards the deflector.The deflector is designed to distribute the water in a pattern that is most effective in controlling the fire. COVERAGE: Residential spray coverage up to 20 feet x 20 feet/6.1 m x 6.1 m room sizes per NFPA. TECHNICAL SPECIFICATIONS: Model:V2740 ACCESSORIES III Style:Pendent and Recessed Pendent Installation Wrench: Nominal Orifice Size:',ll6/12 mm • Open End:V27 K Factor:4.9 Imp./7.1 S.I.^for room sizes up to • Recessed:V27-1 41Ik20'/6.1 m Sprinkler Finishes: ft• Nominal Thread Size:W NPT/15mm • Plain brass �� Max.Working Pressure:175 psi/1200kPa • Chrome plated \ \.._______,SFactory Hydrostatic Test:100%@ 500 psi/ • White painted** \= i 3450kPa • Custom painted** (110Min.Operating Pressure:7psi/48kPa For escutcheons,cabinets and other accessories %.' 44 Temperature Rating:See chart on page 3 refer to separate sheet. Y ^For K-Factor when pressure is measured in l/r� re �, MATERIAL SPECIFICATIONS Bar,multiply S.I.units by 10.0. //� Pendent Deflector:Bronze per UNS C51000 *Teflon is a registered trademark of Bulb:Glass with glycerin solution Dupont Co. Bulb Nominal Diameter: **UL Listed Tor corrosion resistance in all Ilf I Quick Response:3.0 mm configurations. Load Screw: Bronze per UNS C65100 NOTE:Weather resistant recessed escutcheon Pip Cap:Bronze per UNS C65100 available upon request. Seal:Teflon*tape � t Frame:Die cast brass 65-30 mow,,.vv Exaggerated for clarity JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para Location Date Approved • Date www.victaulic.com �CtauIac° VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.0 2013 VICTAULIC COMPANY.ALL RIGHTS RESERVED. REV__E 40.47_::. FIRE PROTECTION PRODUCTS-AUTOMATIC SPRINKLERS 40.47 • ' 4 Residential Pendent and Recessed Pendent V2740 QUICK RESPONSE APPROVALS/LISTINGS orifice Nominal Approved Temperature Ratings Model Size K-Factor Response Deflector Type 'F/`C# v2-/40 12 /1� Quck Pendent t } 68,79 V2740 Mb 4.9 Quick Recessed Pendent 155,175 12 7.1 Up to W Adjustment* 68,79 V2740 Mb 4.9 Quick Recessed Pendent 155,175 12 71 Up to W Adjustment# 68,79 *Listings and approval as of printing. A For K-Factor when pressure is measured in Bar,multiply S.I.units by 10.0. *For 12'x 12'to 20'x20'rooms #For 12'x 12'to 18'x 18'rooms RATINGS All glass bulbs are rated for temperatures from-67°F/-55°C to those shown in table below. Temperature-°F/°c Victaulic Sprinkler Temperature Part Nominal Temperature Maximum Ambient Classification Identification Rating Temperature Allowed Glass Bulb Color Ordinary C 155 100 Red 68 38 • Intermediate E 175 _..... _ 650 Yellow. ORDERING INFORMATION Please specify the following when ordering: Sprinkler Model Number Style Temperature Rating K-Factor Thread Size Quantity Sprinkler Finish Escutcheon Finish Wrench Model Number • . www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.0 2013 VICTAULIC COMPANY.ALL RIGHTS RESERVED. Ictaulic° 40.47_-.2 FIRE PROTECTION PRODUCTS AUTOMATIC SPRINKLERS 40.47 27 . Residential Pendent and Recessed Pendent • V2740 QUICK RESPONSE WARNING A A WARNING • Always read and understand installation,care,and maintenance instructions,supplied with each box of sprinklers,before proceeding with installation of any sprinklers. c • Always wear safety glasses and foot protection. ,,, . • Depressurize and drain the piping system before attempting to install,remove,or adjust any Victaulic piping products. • Installation rules,especially those governing obstruction, must be strictly followed. • Painting,plating,or any re-coating of sprinklers(other than that supplied by Victaulic)is not allowed. 0 Failure to follow these instructions could result in serious personal injury and/or property damage. The owner is responsible for maintaining the fire protection system and devices in proper operating condition.For minimum maintenance and inspection requirements,refer to the current National Fire Protection Association pamphlet that describes care and maintenance of sprinkler (Thsystems. In addition,the authority having jurisdiction may have addi- tional maintenance,testing,and inspection requirements that must be ���, followed. Ify `/'-j If you need additional copies of this publication,or if you have any questions about the safe installation of this product,contact Victaulic World Headquarters:P.O.Box 31, Easton,Pennsylvania 18044-0031 USA,Telephone:001-610-559-3300. • AVAILABLE WRENCHES Sprinkler Type j Open End Recessed V2740 Pendent V27 V27-2 V2740 Recessed Pendent — V27-2 • www.victaulic.com iCtalUlaC: VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.0 2013 VICTAULIC COMPANY.ALL RIGHTS RESERVED. f` FIRE PROTECTION PRODUCTS—AUTOMATIC SPRINKLERS 40.47 V27, K4.9 0 Residential Pendent and Recessed Pendent V2740 QUICK RESPONSE DIMENSIONS Standard Pendent—V2740 MI MEE IFt•rAJ 60 mm • 41Vm8"/m 01) i A L 11A67 30 mm ..— -. Maximum Recess—1/2"Adjustment Recessed—V2740(drawing not to scale) 2W/60 mm Max.Hole --... 2751 mm Min Hole -----,_------ .1=11.1 -— A011 .- Ir IIPAtm., . .mIVIMW 17 mm AEA LIK-77- --,---111 AKE Typical Ceiling Tile 30 mm greOW I.-1 I' AIWA Typical Ceiling Tile 410 PX6"/ 43 mm 411111 inished Surface 1Ya°/ 30 mm ia Finished Surface 11 MAXIMUM RECESS 23/4"/ 75 mm MAXIMUM EXTENSION Maximum Recess—3/4"Adjustment Recessed—V2740(drawing not to scale) 2W/60 mm Max.Hole 2"/51 mm Min.Hole----."- ,-sse/ i 37 mm 1146"/ 'MENEM. 24 mm 18 mmriffigl...- ---,.-± „..BEE Typical Ceiling TileAe,Typical Ceiling Tile ....1.ar.rnier----a`MJ L_ZDAVitrilliArarr 11,Xan/ 24 mm illi Finished Surface 43 mm Finished Surface fiV MAXIMUM RECESS 2,316"/ 75 mm MAXIMUM EXTENSION 1110 www.victaulic.com veic' VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.0 2013 VICTAULIC COMPANY.ALL RIGHTS RESERVED. ctaul 40A7.,4 REV_E FIRE PROTECTION PRODUCTS-AUTOMATIC SPRINKLERS 40.47 7 K4m9 Residential Pendent and Recessed Pendent ID V2740 QUICK RESPONSE ROOM SIZE Victaulic V2740,4.9 K-Factor Pendent Sprinkler For Ceiling types refer to NFPA 13, 13R or 13D 2013 Editions Max. Ordinary Temp Intermediate Temp Coverage Rating Rating Deflector to Installation Minimum Arear°' 155"F/68°C 17511/79°C Ceiling Type Spacing 12 X 12 13 7.0 13 71) 3.7 X 3.7 X9.2 0.48 49.2 0.48 14X14 13 7.0 13 7.0 4.3 X 4.3 49.2 048 49.2 0.48 3/4"recessed 16 X 16 13 70 13 70 Escutcheoni°l 8.0 4.9 X 4.9 49.2 0.48 49.2 0.48 136 to 4 inch or non-recessed i 2.4 per NFPA13,13Ri 18 X 18 17 12 17 12 or 13D 5.5 X 5.5 64.3 0.83 643 0.83 20 X 20 20 16.7 20 16J j I 6.1 X 6.1 75.7 1.15 75.7 1.15 i (a)For coverage area dimensions less than or between those indicated,use the minimum required flow for the next highest coverage area for which hydraulic design criteria are stated. (b)For NFPA 13 residential applications,the greater of 0.1gpm/ft2 over the design area of the flow in accordance with the criteria in the table must be used. (c) For 20 x 20 Coverage Area-1/2"Maximum Recess • • www.victaulic.com VICTAULIC ISA REGISTERED TRADEMARK OF VICTAULIC COMPANY.0 2013 VICTAULIC COMPANY.ALL RIGHTS RESERVED. ICtc'#9.!. REV_E 40.47._5 FIRE PROTECTION PRODUCTS—AUTOMATIC SPRINKLERS 40.47 V27, K49• Residential Pendent and Recessed Pendent V2740 QUICK RESPONSE NOMINAL WETTING PATTERNS Model V2740 K4.9 residential pendent and recessed pendent(Ya") 13 GPM/49.2 LPM—16'x 1674.9 x 4.9 m coverage area 1.8m 1.2m 0.9m 9 6 0.6m 4' u 2'4$ 19m 12m 0.6m 1 1.2m 0.3m 2' 0' 06m Ct OF ROOM Model V2740 K4.9 residential pendent and recessed pendent(44") 17 GPM/64.3 LPM—18'x 1875.5 x 5.5m coverage area 8' 2.4m - ...... ..-... _.._. .. .. • 2.1 m 1.Sm 1.2m 9.9m , n 2 6 0.6m 6 2.4m 14m 1.8m 1.2m 06m 1 4' 1.am 0.3m o 4 12m OF ROOM See notes on next page. 1110 www.victaulic.com VICTAULIC ISA REGISTERED TRADEMARK OF VICTAULIC COMPANY.0 2013 VICTAULIC COMPANY.ALL RIGHTS RESERVED. ICt2iLdIC0 40.47_6 FIRE PROTECTION PRODUCTS—AUTOMATIC SPRINKLERS 40.47 V27 K44 9 Residential Pendent and Recessed Pendent • V2740 QUICK RESPONSE NOMINAL WETTING PATTERNS Model V2740 K4.9 residential pendent and recessed pendent('h") 20 GPM/75.7 LPM—20'x 2016.1 x 6.1 m coverage area 2.4m .. - ..... .. ...._.. -... .-. ,. ... 1.Sm 1 Sm z" 3m< 0.9m 2 10' B' 6• 4' 2' 0' 6• 24m 3,om z.4m 1.Bm�1m 0.6m 1'. 4• 1&n 03m_ ' 2• tzm or ROOM 0, obm NOTES: 1 Data shown is approximate and can vary due to differences in installation. 2 These graphs illustrate approximate trajectories,floor-wetting,and wall-wetting patterns for these specific Victaulic FireLock automatic sprinklers.They are provided as information for guidance in avoiding obstructions to sprinklers and should not be used as minimum sprinkler spacing rules for installation.Refer to the appropriate NEPA National Fire Code or the authority having jurisdiction for specific information regarding obstructions,spacing limitations and area of coverage requirements.Failure to follow these guidelines could adversely affect the perfor- mance of the sprinkler and will void all Listings,Approvals and Warranties. • 3 All patterns are symmetrical to the centerline of the waterway. • www.victaulic.com �CtaU�rC VICTAULIC ISA REGISTERED TRADEMARK OF VICTAULIC COMPANY.®2013 VICTAULIC COMPANY.ALL RIGHTS RESERVED. REV_E 40.47„7 11.4 K4.9 Residential Pendent and Recessed Pendent V2740 QUICK RESPONSE WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications.All products to be installed in accordance with current Victaulic installation/assembly instructions.Victaulic reserves the right to change product specifications,designs and standard equipment without notice and without incurring obligations. S • For complete contact information,visit www.victaulic.com 40.47 4525 REV E UPDATED 04/2013 icto'auIac' VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.0 2013 VICTAULIC COMPANY.ALL RIGHTS RESERVED. x0.47 FireLock® V27, K5.6 J�ta,,i,c Models V2703, V2707, V2704, V2708 40.10 • Standard Spray Technical Specifications: Upright, Pendent and Recessed Pendent Standard and Quick Response Models:V2703, V2704, V2707, V2708 Style: Pendent, Upright or Recessed Pendent . ; Nominal Orifice Size: 1"/13 mm $ ''# ' K Factor. 5.6 Imp./8.1 S.I.1 li* .» Nominal Thread Size: th" NPT/15 mm Max.Working Pressure: a :4,-'::i • 175 psi/1200 kPa (FM) V2703/V2704 V2707/V2708 V2707/V2708 • 250 psi/1725 kPa (UL) Upright Pendent Recessed Pendent Factory Hydrostatic Test: 100% @ 500 psi/3450 kPa Approvals/Listings: Min.Operating Pressure: • 7 psi/48 kPa e u� —__ VdS C$'E O Fps LPCB � • 0.35 bar/5 psi (VdS for upright only) See Victaulic Publication 10.01 for more details. Temperature Rating:See chart 1 For K-Factor when pressure is measured in Bar,multiply S.I.units by 10.0. Product Description: These Model V27 standard spray sprinklers are . designed to produce a hemispherical spray pattern for standard commercial applications. They are available it III with either standard or quick response bulbs. It is castiii with a hex-shaped wrench boss to allow easy tightening7 from many angles, reducing assembly effort. This sprinkler is available in various temperature ratings (see t \ chart on page 3) and finishes to meet many design 2110 requirements. The recessed pendent should be utilized fift with a Model V27 recessed escutcheon which provides i- up to 3/4'719 mm of adjustments. I Coverage i II For coverage area and sprinkler placement, refer to NFPA 13 or applicable standard. Cv Exaggerated for clarity i Job/Owner Engineer System No. Spec Section i Location { I Paragraph Contractor Approved I Submitted By Date Date • victaulic.com I Sprinklers I FireLock®I K5.6,V27 I Publication 40.10 40.10 2544 Rev.J Updated 07/2014 ®2014 Victaulic Company.All rights reserved. 1 ictaulic victaulic.com I Sprinklers I FireLock®I K5.6, V27 I Publication 40.10 Material Specifications: Accessories • Upright Deflector: Bronze per UNS C11000 Pendent Deflector: Bronze per UNS C51000 Installation Wrench: Bulb: Glass with glycerin solution C] Open End: V27 Bulb Nominal Diameter: El Recessed: V27-2 ❑ Standard: 5.0 mm Sprinkler Finishes: ❑ Quick Response:3.0 mm ❑ Plain Brass Load Screw: Bronze per UNS C65100 ❑ Chrome plated Pip Cap: Bronze per UNS C65100 ❑ White painted3 Spring: Beryllium nickel ❑ Black painted3 Seal:Teflon2 tape ❑ Custom painted3 Frame: Die cast brass 65-30 Cl Proprietary Nickel Teflon2 coating3 Lodgement Spring: Stainless steel per UNS S30200 ❑ VC-2504 155, 200,286 SR Only: ❑ Wax3 For cabinets and other accessories refer to separate sheet. 2 Teflon is a registered trademark of Dupont Co. 3 UL Listed for corrosion resistance. 4 UL Listed and FM Approved for corrosion resistance. i _ - - - --- - -� 40.10 2544 Rev.J Updated 07/2014 ®2014 Victaulic Company.All rights reserved. victaulic.com 2ictaulid victaulic.com I Sprinklers I FireLocke I K5.6,V27 I Publication 40.10 Approvals/Listings: APPROVALS/LISTINGS Model 411 V2703 V2707 V2707 V2704 ' V2708 V27087 Orifice Size(inches) 1/2" 1h" 1/2" 1/2" 1/z" 1/2" Orifice Size 13 13 13 13 13 13 Nominal K Factor Imperial 5.6 5.6 5.6 5.6 5.6 5.6 Nominal K Factor S.I 5 8.1 8.1 8.1 8.1 8.1 8.1 Response Standard I Standard Standard Quick Quick _ Quick Recessed Recessed Deflector Type Upright Pendent Pendent Upright Pendent Pendent rApproved Temperature Ratings F!C° 135°F/57°C 135"F/57°C 135"F157°C I 135°F/57°C 135°F/57°C 155°F/68°C 155°F/68°C135°F/57°C 155°F/68°C 155°F/68°C 155°F/68°C 155°F/68°C 175°F/79°C 175°F/79°C cULus 175°F/79°C 175°F/79°C 175°F/79°C 200°F/93°C 200°F/93°C175°F/79°C 200°F/93°C 200°F/93°C 200°F/93°C 286°F/141°C 286°F/141°C200°F/93°C 360°F/182°C 360°F/182°C 286"F/141°C 286°F/141°C 286°F/141°C 135°F/57°C 135°F/57°C 135°F/57°C 135°F/57°C 155°F/68°C 155°F/68°C 135°F/57°C755°F/68°C 155°F/68°C 135°F/57°C FM 175°F/79°C 175°F/79°C 155°F/68°C 175°F/79°C 175°Fl79°C 155°F/68°C 200°F/93°C 200°F/93°C 175°F/79°C200°F/93°C 200°F/93°C 175°F/79°C 286°F/141°C 286°F/141°C 200°F/93°C200°F/93°C 286°F/141°C 286°F/147°C 360°F/182°C 360°F/182°C 135°F/57°C 135°F/57°C 135°F/57°C 135°F/57°C 135°F/57°C 155°F/68°C 155°F/68 C135°F/57°C 155°F/68°C 155'F/68°C 155°F/68°C 175°F/79°C 175°F/79°C155°F/68°C NYC/MEA 62-99-E i 200°F/93°C 200°F/93°C 175°F/79°C 175°F/79°C 175°F/79°C 175°F/79°C 200°F/93°C 200°F/93°C 200°F/93°C JI 286°F/141°C 286°F/741°C286°F/141°C 286°F/141°C 286°F/141°C 200°F/93°C 360°F/182°C 360°F/182°C H------ 135°F/57°C 135°F/57°C 155°F/68°C 155°F/68°C 135°F/57°C 135°F/57°C 135°F/57°C 135°F/57°C °F/68°C 155°F/68°C 155°F/68°C 175°F/79°C 175°F/79°C155°F/68°C CSFM 7690-0531:112 175°F/79°C 175°F/79°C 175°F/79°C 200°F/93°C 200°Fl93°C200°F/93°C 200°F/93°C 200°F/93°C 175°F/79°C 286°F/141°C 286°F/141°C200°F/93°C { 360°F/182°C 360°F/182°C 286°F/141°C 286°F/141°C 286°F/141°C 0 735°F/57°C 155°F/68°C 135°F/57°C 175°F/79°C 155°F/68°C LPCB200°F/93°C None None 175°F/79°C None None 286°F/741°C 200°F/93°C 360°F/182°C 135°F/57°C 135°F/57°C 135°F/57°C 135°F/57°C 155°F/68°C 155°F/68°C 135°F/57°C755°F/68°C 155°F/68°C 135°F/57°C VNIIPO 175°F/79°C 175°F/79°C 155°F/68°C 175°F/79°C 775°F/79°C 155°F/68°C 200°F/93°C 200°F/93°C 175°F/79°C200°F/93°C 200°F/93°C 175°F/79°C 286°F/141°C 286°F/141°C 200°F/93°C200°F/93°C 286°F/141°C 286°F/141°C 360°F/182°C 360°F/182°C k---- _____�}_ _— _ —u ZSTZ �ZSTX K-ZSTZ K-ZSTZ CCC 155°F/68°C 155°F/68°C None 155°F/68°C 155°F/68°C None •:' /93°C j 200°F/93°C 200°F/93°C 200°F/93°C 135°F/57°C { 155°F/68°C 135°F/57°C 175°F/79°C 155°F/68°C VdSNone None 175°F/79°C None None 200°F/93°C 200°F/93°C 286°F/141°C 286°F/141°C 360°F/182°C I 135°F/57°C 135°F/57°C 155°F/68°C 155°F/68°C CE 175°F179°C None None 175°F/79°C i None None 200°F/93°C 200°F/93°C ( [ 286°F/141°C 360°F/182°C + 286°F/141°C i I For K Factor when pressure is measured in Bar,multiply S.I.units by 10.0 FM Approved with I/2"adjustment escutcheon only-quick response Note:Listings and Approvals as of printing.All are approved open. • 40.10 2544 Rev.J Updated 07/2014 ©2014 Victaulic Company.All rights reserved. victaulic.com 3 ictaulic victaulic.com I Sprinklers I FireLock°I K5.6, V27 I Publication 40.10 Dimensions: 0 37 mm I I t 1 �_ 04 13'e7 � r ,i 2 7 41 mm 60 mm is/eY 60 mm Lit 41 mm ' Standard Pendent– Standard Upright– V2707,V2708 V2703,V2704 23/4"/60 mm -.—Max.Hole 2"/51 mm I'^Min.Hole — 7 7445110„sail M� + Qlgr ■ aa��i/A 17 mm _ Typical CeilingTile r®� 30 mm 1".7 t1386'/ 43 mm ITO Finished Surface r 30 m .---- MAXIMUM RECESS 2'4Sd/ 75mm • MAXIMUM EXTENSION '/z"Adjustment Recessed–V2707,V2708(drawing not to scale) 23/4760 mm Max.Hole —.- 2751 mm Min.Hole 24mm 18 mm MEM.rili�.>�� Typical Ceiling Tile �/,P__"1r11�I.11!.� 3 L m gull —1 I t VI } ���J ' 67Finished Surface 24mm MAXIMUM RECESS 2,w/ - 75mm MAXIMUM EXTENSION 3/a'Adjustment Recessed–V2707,V2708(drawing not to scale) Ili _ _ -- ____ ._ 40.10 2544 Rev.J Updated 07/2014 ®2014 Victaulic Company.All rights reserved. victaulic.com 4 ictaulic” victaulic.com I Sprinklers I FireLock®I K5.6, V27 I Publication 40.10 Distribution Patterns: Models V2707,V2708 III K5.6 Standard Pendent and Recessed Pendent Distribution Patterns—Trajectory 10'i 3.001 •..'•• •' •` •'. • �no n1 i••-S • •` • .� .�•� • .•.. ...... ., 7p51 0/011••• ••111801 � 6' • ....\ ''*`. 15 psi ........=� •` .•• 103 kPa 4' • 1 2 .•� 30 psi .` `• 207 kPa 2' \ 0601 o. • 0 2 4' 6' 8' 10' 12' 14' 0.6m 1.2m 1.8m 2.461 3.0m 3.701 4.3m Models V2703,V2704 K5.6 Standard Upright Distribution Patterns—Trajectory 10 3 Om 401 • • • 6 '', 48 kPa 1.a„1 •`• .'•• 15 psi 103 kPa 1,201 '. • 30 psi •'. 207 kPa .` . '`. 2' • 0.6m �•` • .. 0 _ 4 8' 8' 10' 12' 14' 16' 0 C 1.201 1 cm 2 4r 3.0m 3.701 4.3m 4.9m NOTES: - A.Data shown is approximate and can vary due to differences in installation. B.These graphs illustrate approximate trajectories,floor-wetting,and wall-wetting patterns for these specific Victaulic FireLock Automatic Sprinklers.They are provided as information for guidance in avoiding obstructions to sprinklers and should not be used as minimum sprinkler spacing rules for installation.Refer to the appropriate NFPA National Fire Code or the Authority Having Jurisdiction for specific information regarding obstructions,spacing limitations and area of coverage requirements.Failure to follow these guidelines could adversely affect the performance of the sprinkler and will void all Listings,Approvals and Warranties. C.All patterns are symmetrical to the centerline of the waterway. — el 40.10 2544 Rev.J Updated 07/2014 C 2014 Victaulic Company.All rights reserved. victaulic.com 5ictaul.d victaulic.com I Sprinklers I FireLock®I K5.6, V27 I Publication 40.10 Ratings: Available Wrenches: • All glass bulbs are rated for temperatures from -67°F — (-55°C)to those shown in the table below. V27-2 V27 Recessed Open End 1 Temperature-°F/°C V2707,V2708 Pendent ✓ I ✓ } Maximum I V2707,V2708 Recessed Pendent ✓ - Sprinkler Victaulic Nominal Ambient Glass I Temperature Part Temperature Temperature Bulb 1 I V2703,V2704 Upright + - .1Classification Identification Rating Allowed Color Ordinary � A ' 135°F/57°C 100°F/38°C Orange I __ Ordinary I C 155°F/68°C 100°F/38°C Red 1 Intermediate E 175°F/79°C ! 150°F/65°C Yellow i ; Intermediate F 1 200°F/93°C j 150°F/65°C 1 Green 1 1.._ I I High J i 286°F/141°C'225°F 8/107°C1 Blue i Extra High 7 K 360°F/182°C 300°F/149°C Purple - M Open - ; No Bulb I 7 Standard response only. 8 150/65 if wax coated. ARNI ° .,. .,....,., . 0 4 • Always read and understand installation,care,and maintenance instructions,supplied with each box of sprin- klers,before proceeding with installation of any sprinklers. • Always wear safety glasses and foot protection. • Depressurize and drain the piping system before attempting to install,remove,or adjust any Victaulic piping products. • Installation rules,especially those governing obstruction,must be strictly followed. • Painting,plating,or any re-coating of sprinklers(other than that supplied by Victaulic)is not allowed. 0 Failure to follow these instructions could result in serious personal injury and/or property damage. The owner is responsible for maintaining the fire protection system and devices in proper operating condition.For minimum maintenance and inspection requirements,refer to the current National Fire Protection Association pam- phlet that describes care and maintenance of sprinkler systems. In addition,the authority having jurisdiction may have additional maintenance,testing,and inspection requirements that must be followed. If you need additional copies of this publication,or if you have any questions about the safe installation of this product,contact Victaulic World Headquarters:P.O. Box 31, Easton,Pennsylvania 18044-0031 USA,Telephone: ,L/-- 001-610-559-3300. 17) Installation Note Reference should always be made to the 1-40 Victaulic FireLock Automatic Sprinklers This product shall be manufactured by Victaulic or to Victaulic specifications.All products Installation and Maintenance Sheet for the product you are installing.This installation sheet to be installed in accordance with current Victaulic installation/assembly instructions. is included with each shipment of Victaulic products for complete installation and assembly Victaulic reserves the right to change product specifications,designs and standard data,and is available in PDF format on our website at victaulic.com. equipment without notice and without incurring obligations. Warranty Trademarks Refer to the Warranty section of the current Price List or contact Victaulic for details. Victaulic is a registered trademark of Victaulic Company. • 40.10 2544 Rev.J Updated 07/2014 ©2014 Victaulic Company.All rights reserved. victaulic.com 6 ,ctaul,c FireLock® V36, K5.6 ✓ctaul,ce Models V3609, V3610 40.64 • Dry Type Standard Spray, Light Hazard Technical Specifications: Horizontal and Recessed Horizontal Sidewall Standard and Quick Response Models:V3610 and V3609 Style: Horizontal Sidewall and Recessed Horizontal Sidewall Nominal Orifice Size: W/13 mm Flush Dry Recessed Orifice Insert:Stainless steel per UNS S30300 Horizontal Sidewall Horizontal Sidewall K-Factor: 5.6 Imp./8.1 S.I.1 z � Nominal Thread Size: 1" NPT/33.7 mm ANC' Max.Working Pressure: 175 psi/1200 kPa Dry Sleeve&Skirt Extended Plain Horizontal Sidewall Horizontal Sidewall Horizontal Sidewall Factory Hydrostatic Test: 100% ®500 psi/3450 kPa Approvals/Listings: Min.Operating Pressure: 7psi/48 kPa e®os FM Temperature Rating: See chart on page 3. usrm For K-Factor when pressure is measured in Bar,multiply S.I.units by 10.0. See Victaulic Publication 10.01 for more details. Product Description: ' .tvl✓it/if/iYiS/�SOYiS/eY�S/iI/iI/N•�� The V36 dry sprinkler is used in special applications such 7� .�.rs.�y�,F �..�Nal 411 as freezing environments and conditions where sediment �.�_, C or foreign materials might accumulate in ordinary att "•"_ _ ; ,,,j;,,r,I,A,,s,AGVAIAIWAVAIACOr LV 11111 horizontal pipe nipples. r I The Model V36 Dry Type Horizontal Sidewall Sprinkler utilizes a frangible glass bulb.At the bulb's rated Exaggerated for clarity temperature,the sprinkler opens releasing the bulb seat assembly,causing the inner tube assembly to move,allowing the spring assembly to pivot alongside the inner tube.At this time,water flows through the sprinkler and is distributed by the deflector,in an approved discharge pattern. Coverage For coverage area and sprinkler placement, refer to NFPA 13 or applicable standards. Job/Owner Engineer System No. Spec Section Location Paragraph Contractor I Approved Submitted By I Date Date • victaulic.com I Sprinklers I FireLock®I K5.6,V36 I Publication 40.64 40.64 3127 Rev.J Updated 6/2014 ©2014 Victaulic Company.All rights reserved. 1 �ctaul.c victaulic.com I Sprinklers I FireLock®I K5.6, V36 I Publication 40.64 Material Specifications: Accessories 4110 Deflector: Brass per UNS C22000 or Stainless Steel per Installation Wrench: UNS S30400 Model V36 Open End and Recessed Wrenches fit all Bulb: Glass with glycerin solution V36 Series frames. Bulb Nominal Diameter: Sprinkler Finishes: ❑ Plain brass ❑ Standard: 5.0 mm ❑ Quick Response:3.0 mm El Chrome plated ❑ White painted3 Split Spacer:Stainless steel per UNS S30300 ❑ Flat black painted3 Load Screw: Brass per UNS C36000 ❑ Custom painted3 Pip Cap: Stainless steel per UNS S30300 ❑ Proprietary Nickel Teflon2 Coated3 ❑ VC-2504 Spring Seal Assembly:Teflon2 coated Beryllium nickel 155, 200, 286 SR Only: alloy and stainless steel per UNS S30300 ❑ Wax3 Frame: Die cast brass For cabinets and other accessories refer to separate Outer Tube:Galvanized steel pipe sheet. 3 Teflon is a registered trademark of Dupont Co. Inner Tube:Stainless steel per UNS S30400 3 UL Listed for corrosion resistance. UL Listed and FM Approved for corrosion resistance. Escutcheon/Plate: 1010- 1018 mild steel and stainless steel NOTE:Weather resistant escutcheon available upon request. Torsion Spring: Stainless Steel Wire • — — 40.64 3127 Rev.J Updated 6/2014 ©2014 Victaulic Company.All rights reserved. victaulic.com 2 V'GtsuIiC victaulic.com I Sprinklers I FireLock®I K5.6,V36 I Publication 40.64 Approvals/Listings: Model • APPROVALS/LISTINGS — V3610 I V3610 i V3609 V3609 II Orifice Size(inches) th 'k '/z 'h Orifice Size(mm) 13 � 13 j 13 ; 13 Nominal K Factor Imperial 5.6 I 5.6 5.6 5.6 Nominal K Factor S.1.5 8.1 8.1 t 8.1 8.1 Response Quick Quick j Standard Standard Recessed Horizontal { Recessed Horizontal . Deflector Type Horizontal SidewaliSidewali ( Horizontal Sidewall I Sidewall Approved Temperature Ratings F%C° 135°F/57°C 135°F/57°C 135°F/57°C 135°F/57°C caw 6 155°F/68°C 155°F/68°C 155°F/68°C 155°F/68°C — 200°F/93°C� 200°F/93°C 200°F/93°C 200°F/93°C 286°F/141°C 286°F/141°C 286°F/141°C 286°F/141°C 135°F/57°C135°F/57°C 135°F/57°C 135°F157°C 155°F/68°C 155°F/68°C FM 155°FJ68°C 155°F/68°C 200°F/93°C 200°F/93°C 1 286°F/141°C 200°F/93°C 286°F/141°C 200°FJ93°C s For K-Factor when pressure is measured in Bar,multiply S.I.units by 10. 6 Light Hazard Only-Listed for light hazard only with deflector from 4"—12°below the ceiling. Note:Listings and approval as of printing.Temperatures approved for V3609 and V3610 up to 48°length for cULus and 36"for FM. Dimensions: NOTE:The"A"dimension of a dry sprinkler,which extends into a freezer from a wet piping system,must take into account the wall or ceiling thickness of the freezer.See IMPORTANT INSTALLATION INFORMATION later in this document. (Hirt.W1-1 A • Mt,1W) _.1..,_w III ., TrohEscutcheon —_-�I .I_—Al.��- - I:=<�l rNPr � ,—III' ;-_- 3�' I.NPT iii i. Tee Mi same Hok'nWall 1 TTrr 1W Mtn.Dia. a"Dia. outlet size as Teelet size Foie in Wall ;MIn outlet size as sprinkler thread 4W'Ma—' sprinkler thread // 2W size. size. ' See"Important See"Important Installation Installation Fkah Information",later sleeve”kart Information",later in this document in this document " I Min.1W") I'NOT n m".Ble ` Wall CUP _ Hokin Wall �r---a ) \ I Co/lar (Min.111 I ±1 ' 1"NPT 1'OPT C . :`�'.. 3W' �_.-__J I ` • MI j Teewith same N L__—_: outlet size as T Nese --r- 2'Min.Da. \ sprinkler thread Escutcheon Tee with same mein wall �--it size. outlet size as l;b"Mw- Tee with same .--2W"' See"Important "p" I e.M;n sprinkler thread \ 20 Ma`s outlet size as Installation �IMm.IW1 �a.Min Size. N sprinkler Information",later size. Plain Barrel Extended See"Important Recessed in this document Installation See"Important Information",later Installation in this document Information",later in this document Deflector to ceiling distance 4—12"/102—305 mm for all configurations shown above. • 40.64 3127 Rev.J Updated 6/2014 C 2014 Victaulic Company.All rights reserved. victaulic.com 3 xictaulid victaulic.com I Sprinklers I FireLock®I K5.6, V36 I Publication 40.64 Important Installation Information: NOTE: • For detailed installation instructions,see publication 1-40. The"A"dimension of a dry sprinkler,which extends into a freezer from a wet piping system,must take into account the wall or ceiling thickness of the No. 1 Victaulic Model V36 Series Dry sprinklers should freezer.The minimum length of the dry sprinkler should not be less than the lengths specified in the following table,plus the thickness of the freezer's wall be installed in accordance with NFPA 13. These or ceiling("A"="C"+"D"). sprinklers are to be installed using a pipe wrench Refer to the drawing for a representation of the"A"dimension.DO NOT applied to the outer tube. When this is not attempt to modify dry sprinklers,since they are manufactured to this specific possible,the proper sprinkler wrench may be "A"dimension. used with extreme care for lengths up to The following table is used when the ambient temperature is maintained approximately 18". Excessive force may distort the between 40°F/4°C and 607/16°C around the wet piping system. frame thus destroying the unit. Ambient Temperature No. 2 Dry sprinklers MUST be installed only into the Exposed to Discharge 1 outlet of a cast or malleable iron tee. End of Sprinkler Exposed Minimum Barrel Length i °F/°C inches/mm i No. 3 DO NOT install dry sprinklers into any couplings or 40"F14°C I 50°F/10°C 60eF/16°C threaded elbows. In addition, DO NOT install 40 0 0 0 dry sprinklers into any fitting that interferes with .. 4 0 0 0 thread penetration. NOTE: The end seal of the i 30 I o 0 0 dry sprinkler MUST NOT bottom out in the fitting. �,. 20 4 o o i -7 102 0 0 ?� Er " 10 8 1 1 0 End seal , HEATED SPACE -12 203 25 0 bhp— I h=Fi 0 12 i — 3 0 I 8= 18 305 76 0 i ^10 — E 14 4 1 .c.Exposed Minimum Barrel -23 I 356 102 25 Length(Refer to Table) I Diameter of hole is dependent upon the type of escutcheon selected.space must � -20 ( 14 6 3 i be sealed to prevent condensation from } forming,per NFPA requirements. -30 16 8 4 • rsee ote -34 406 203 102 N -40 18 $ 4A Insulation -40 ( 457 281 03 102 D i -50 20 10 6 -46 508 254 152 -60 20 10 6 5- 1 508 254 152 Wall or Ceiling of Freezer L. -- ---____.L..,_.._.-. Note:Exposed minimum barrel lengths are inclusive up to 30-mph/48-kph wind velocities i■moi, irol! 'liar COLD SPACE Exaggerated for Clarity TYPICAL SLEEVE AND SKIRT CONFIGURATION FOR EXAMPLE ONLY ill 40.64 3127 Rev.J Updated 6/2014 ©2014 Victaulic Company.All rights reserved. victaulic.com 4ictauli0 victaulic.com I Sprinklers I FireLock®I K5.6, V36 I Publication 40.64 Distribution Patterns: Models V3610,V3609 • Horizontal Sidewall and Recessed Horizontal Sidewall Distribution Patterns-Trajectory •s •♦ - 7 psi 2.4 m •♦448 kPa 6' ` ♦♦ 1.8 m '. ♦♦♦ 15 psi ��. ♦ 103 kPa 1.2 m `•• ♦♦ 30 psi ` ♦ 207 kPa 2' • 0.6m �♦ 0 4 2' 4' 6' 8' 10' 12' 14' 16' 18' 20' 22' 24' 26' 0.6m 1.2 m 1.8m 2.4 m 3.0m 3.7m 4.3 m 4.9m 5.5 m 6.1 m 6.7m 7.3 m 7.9 m Models V3610,V3609 Horizontal Sidewall and Recessed Horizontal Sidewall Distribution Patterns-Trajectory 2' 4' 6' 8' 10' 12' 14' 16' 18' 20' 22' 24' 26' 28' 0.6 m 1.2 m 1.8 m 2.4m 3.0m 3.7 m 4.3 m 4.9m 5.5 m 6.1 m 6.7m 7.3m 7.9 m 8.5 m 0 ritIBE 2' • 0.6 m ♦ 4' ' 1.2 ♦ ♦ 7psi �..�... • 6' 48 kPa 1.8m 8' 4 15psi2.4m •• 103 kPa .00° • 10' �••. 30psi 3.Om •� ♦ • 207 kPa I• •12' .,3.7m .14' / )/ 43mi 16' • 4.9m NOTES: A.Data shown is approximate and can vary due to differences in installation. B.These graphs illustrate approximate trajectories,floor-wetting,and wall-wetting patterns for these specific Victaulic FireLock automatic sprinklers.They are provided as information for guidance in avoiding obstructions to sprinklers and should not be used as minimum sprinkler spacing rules for installation.Refer to the appropriate NFPA National Fire Code or the authority having jurisdiction for specific information regarding obstructions,spacing limitations and area of coverage requirements.Failure to follow these guidelines could adversely affect the performance of the sprinkler and will void all Listings,Approvals and Warranties. C.All patterns are symmetrical to the centerline of the waterway. ,-__ _________ lil 40.64 3127 Rev.J Updated 6/2014 C 2014 Victaulic Company.All rights reserved. victaulic.com 5 .ctaulic° victaulic.com I Sprinklers 1 FireLock'I K5.6, V36 I Publication 40.64 Ratings: Available Wrenches: • All glass bulbs are rated for temperatures from Model V36 Open End and Recessed Wrenches fit all -67°F/-55°C to those shown in table below. V36 Series frames. Temperature—°F/°C l ',I.. Maximum Sprinkler Victaulic Nominal I Ambient Glass Temperature Part Temperature Temperature Bulb Classification IdentificationRating Allowed Color Ordinary ( A 135°F/57°C 100°F/38°C Orange Ordinary C 155°F/68°C 100°F/38°C Red Intermediate E 175°F/79°C 150°F/65°C Yellow i_ _ Intermediate I F 200°F/93°C 150°F/65°C Green High J 286°F/141°C 225°F/107°C!- Blue Extra High K 360°F/182°C 300°F/149°C Purple M Open - No Bulb A WARNING • Always read and understand installation,care,and maintenance instructions,supplied with each box of sprin- c klers,before proceeding with installation of any sprinklers. • Always wear safety glasses and foot protection. • 110# • Depressurize and drain the piping system before attempting to install,remove,or adjust any Victaulic piping � products. • Installation rules,especially those governing obstruction,must be strictly followed. • Painting,plating,or any re-coating of sprinklers(other than that supplied by Victaulic)is not allowed. 0 Failure to follow these instructions could result in serious personal injury and/or property damage. The owner is responsible for maintaining the fire protection system and devices in proper operating condition.For minimum maintenance and inspection requirements,refer to the current National Fire Protection Association pam- phlet that describes care and maintenance of sprinkler systems. In addition,the authority having jurisdiction may have additional maintenance,testing,and inspection requirements that must be followed. If you need additional copies of this publication,or if you have any questions about the safe installation of this product,contact Victaulic World Headquarters:P.O. Box 31, Easton,Pennsylvania 18044-0031 USA,Telephone: 001-610-559-3300. 810 Installation Note Reference should always be made to the I-100 Victaulic Field Installation Handbook for This product shall be manufactured by Victaulic or to Victaulic specifications.All products the product you are installing.Handbooks are included with each shipment of Victaulic to be installed in accordance with current Victaulic installation/assembly instructions. products for complete installation and assembly data,and are available in PDF format Victaulic reserves the right to change product specifications and standard equipment on our website at www.victaulic.com. without notice and without incurring obligations. Warranty Trademarks Refer to the Warranty section of the current Price List or contact Victaulic for details. Victaulic and Firelock°are registered trademarks of Victaulic Company. • 40.64 3127 Rev.J Updated 6/2014 ©2014 Victaulic Company.All rights reserved. victaulic.com 6 rctau6d FireLock® V27, K5.6 %tauIic Models V2709,V2710 40.11III Standard Spray Technical Specifications: Horizontal and Recessed Horizontal Sidewall Standard and Quick Response Models:V2709,V2710 Style: Horizontal Sidewall or Recessed ! Horizontal Sidewall :� "'' k 1 4 11 -_1.' Nominal Orifice Size: 1/2"/13 mm ' / K Factor:5.6 Imp./8.1 S.I.1 Nominal Thread Size: 1/2"/15 mm V2709/V2710 V2709/V2710 Max.Working Pressure: Standard Horizontal Recessed Horizontal Sidewall Sidewall • 175 psi/1200 kPa (FM) • 250 psi/1725 kPa (UL) Approvals/Listings: Factory Hydrostatic Test: 100% @ 500 psi/3450 kPa Min.Operating Pressure: c®usQ LL—C@ 0 • 7 psi/48 kPa See Victaulic Publication 10.01 for more details. Temperature Rating:See chart on page 3 1 For K-Factor when pressure is measured in Bar,multiply S.I.units by 10.0. Product Description: These Model V27,standard spray horizontal sidewall / sprinklers are designed for up to ordinary Hazard per NFPA 13,and can be used for standard or recessed J installations.The design provides a crescent-shaped �J • water discharge pattern for installation along a wall or under a beam or ceiling. It is cast with a hex-shaped0 wrench boss to allow easy tightening from many angles, reducing assembly effort. This sprinkler is available in various temperature ratings(see chart on page 3) \. and finishes to meet many design requirements.The recessed pendent should be utilized with a Model V27 ‘1,1 t recessed escutcheon which provides up to 3/4719 mm of \ -.I 1 adjustments. I - T Coverage I� For coverage area and sprinkler placement, refer to NFPA 13 or applicable standard. \ CID Exaggerated for clarity Job/Owner Engineer System No. Spec Section Location Paragraph Contractor , Approved Submitted By I Date � III Da1 te I victaulic.com I Sprinklers I FireLock®I K5.6, V27 I Publication 40.11 40.11 2545 Rev..1 Updated 07/2014 ©2014 Victaulic Company.All rights reserved. 1 1ctaull.c' victaulic.com I Sprinklers I FireLock®I K5.6, V27 I Publication 40.11 Material Specifications: Accessories • Horizontal Deflector:Commercial bronze per Installation Wrench: UNS C22000 Bulb: Glass with glycerin solution El Open End:V27 ❑ Recessed: V27-2 Bulb Nominal Diameter: ❑ Standard: 5.0 mm Sprinkler Finishes: ❑ Quick Response:3.0 mm ❑ Plain Brass Load Screw: Low Silicon bronze per UNS C65100 ❑ Chrome plated Pip Cap: Low Silicon bronze per UNS C65100 ❑ White painted3 Spring: Beryllium nickel ❑ Flat black painted3 Seal:Teflon2 tape ❑ Custom painted3 Frame: Die cast brass 65-30 ❑ Proprietary Nickel/Teflon2 coating3 Lodgement Spring: Stainless steel per UNS S30200 ❑ VC-2504 155, 200, 286 SR Only: ❑ Wax3 For cabinets and other accessories refer to separate sheet. NOTE:Weather resistant recessed escutcheon available upon request. 2 Teflon is a registered trademark of Dupont Co. aUL Listed for corrosion resistance. • 4 UL Listed and FM Approved for corrosion resistance. • 40.11 2545 Rev.J Updated 07/2014 ®2014 Victaulic Company.All rights reserved. victaulic.com 2 victautie victaulic.com I Sprinklers I FireLocke I K5.6, V27 I Publication 40.11 Approvals/Listings: APPROVALS/LISTINGS Model • V2709 V2709 Recessed V2710 V2710 Recessed V2710 Recessed i Orifice Size(inches) 1/2" 1/2" 1/2" 1/2" '/2" Orifice Size(mm) 13 13 j 13 13 13 Nominal K Factor Imperial 5.6 5.6 5.6 5.6 5.6 Nominal KFactor 5.l5 8.1 8.1 8.1 8.1 1 — 8.1 Response i Standard Standard Quick Quick Quick Recessed Recessed ; Recessed Horizontal Horizontal Horizontal Horizontal Deflector Type Horizontal SidewallSidewall Sidewall(up to Sidewall(up to Sidewall 111 1h°adjustment) j 3/4"adjustment) Approved Temperature Ratings F°/C° 135°F/57°C 155°F/68°C 135°F/57°C 135°F/57°C 135°F/57°C 135°F/57°C 155"F/68°C 175°F/79°C 155°F/68°C155°F/68°C 155°F/68°C cULus 200°F/93°C 175°F/79°C 175°F/79°C 175°F/79°C 175°F/79°C 200°F/93°C 286°F/141°C 200°F193°C200°F/93°C 200°F/93°C 286°F/141°C — 360°F/182°C 1 1 135°F/57°C 135°F/57°C �� 155°F/68°C 135°F/57°C 155°F/68°C 135°F/57°C 175°F/79°C 155°F/68°C155°F/68°C FM 6 200°F/93°C 175°F/79°C 175°F/79°C 175°F/79°C None { 200°F/93°C 286°F/141°C 200°F/93°C200°F/93°C 360°F/182°C +{ 286°F/141°C — — I — t-- { 135°F/57°C 135°F/57°C 155°F/68°C 135°F/57°C i 135°F/57°C 135°F/57°C 175°F/79°C 155°F/68°C ( 155°F/68°C155°F/68°C 155°F/68°C NYC/MEA 6#62-99-E 200°F/93°C 175°F/79°C 175°F/79°C { 1757/79°C 175°F/79°C 200°F/93°C I 286°F/141°C i 200°F/93°C286°F/141°C 200°F/93°C 200°F/93°C 360°F/182°C � 135°F/57°C 155°F/68°C 135°F/57°C 135°F/57°C i 135°F/57°C 135°F/57°C 175°F/79°C 155°F/68°C 155°F/68°C 155°F/68°C 155°F/68°C ! . { CSFM 6#7690-0531:112 200°F/93°C 175°F/79°C 175°F/79°C 175°F/79°C 175°F/79°C I 286°F/141°C ; 200°F/93°C 200°F/93°C 200°F/93°C 200°F/93°C 286°F/141°C 360°F/182°C 735°F/57°C 155°F/68°C 135°F/57°C LPCB6104b/01 175°F/79°C 155"F/68°C 6104b/02 200°F/93°C { None 175°F/79°C None None 286°F/147°C 200°F/93°C 360"F/182°C 286°F/141°C —7 135°F/57°C 135°F/57°C 155°F/68°C 135°F/57°C135°F/57°C 155°F/68°C 175°F/79°C 755°F/68°C155°F/68°C { VNIIPO 200°F/93°C 175°F/79°C 175°F/79°C 175°F/79°C None 286°F/141°C 200°F/93°C 200°F/93°C 200°F/93°C } 360°F/182°C ( 286°F/141°C CCCf ZSTBS None None None r None 1 755°F/68°C 5 For K Factor when pressure is measured in Bar,multiply S.I.units by 10.0 6 Light Hazard ONLY Note:Listings and Approvals as of printing.All are approved open. _- - - -- - III 40.11 2545 Rev.J Updated 07/2014 ©2014 Victaulic Company.All rights reserved. victaulic.com 3 ictaulhC victaulic.com I Sprinklers I FireLock®I K5.6, V27 I Publication 40.11 Dimensions: • L 3"/89 mm — 2'/4757 mm 1 IM 11/47 i.�Ara',®��I 'a I11 mm Standard HSW—V2709,V2710 11/16"/ 17 mm • ,x_23/16'/ 11/16' 11/16'/ ��y/��55 mmmmy ��y� pp {��43 mm 30mm I- 7WASI//fyD�'dfi i 1 •i�lrffen a� 4-12'/102-305 mm ` Finished Ceiling 4 12'J102-305mm Finished Ceiling Per NFPA IN Per NFPA In t I: �.1 —� J 2"/51 mm 23/8"/60 mm �� 2"/51 mm 23/8"/60 mm l� 215/16'/ :v �7i]l;;A Min. ale Max.Hole 75 mm �7�, Min. ole Max.Hole NI 101 1 IN OR Finished Surface II Finished Surfac• +F 1 1 Typical Wall Typical Wall MAXIMUM EXTENSION MAXIMUM RECESS III Y2"Adjustment Recessed—V2709,V2710(drawing not to scale) 15/16'/1I...._� 24 nen ,_23/16"/ 9/16"/18 mm 7/16" 5/16" �y56 mm • 37mm 3377 mm ��r 7IPi0 aMit Rd. A if AIM SS EIL�r. Fnished ceiling Finished Ceiling 4-12"/102-305 mm 4-12"7102-305 mm Per NFPA �I Per NFPArt �C__�i 2/51 mm 23/8"/60 mm �I 2'/51 mm 23/8'/50 mm 215/16'/ i� �'I [ Min.Hole Max Hole 7S mm �_i Min.Hole Max Hole ill IN IM finished Surface Hnished Surface Typical Wall Typical Wall MAXIMUM EXTENSION MAXIMUM RECESS 44'Adjustment Recessed—V2709,V2710(drawing not to scale) III 40.11 2545 Rev.J Updated 07/2014 ©2014 Victaulic Company.All rights reserved. victaulic.com 4 ictaulid victaulic.com I Sprinklers I FireLock®I K5.6, V27 I Publication 40.11 Distribution Patterns: Models V2709,V2710 • K5.6 Standard Horizontal Sidewall and Recessed Horizontal Sidewall Distribution Patterns-Trajectory 10' .EC . ` - .., ................. „ 30 . .. , ••• 7psi . ••=.,..•2.4m ` ♦• 48kPa .44 '� •♦♦ ♦ 6' ♦♦ 15 psi 1.8 m ‘. ♦ 103 kPa • • 1.2 m `� ♦♦ 30 psi ♦ 207 kPa ` • 0,6 m . ` • • 1.0 2' 4' 6' 8' 10' 12'14 16 18' 20' 22' 24� 26' 0,6m 1,2m 1,8m 2.4m 3.0m 3.7m 4.3m 4.9m 5.5m 6.1 m 6.7m 7.3m 7.9m Models V2709,V2710 K5.6 Standard and Recessed Horizontal Sidewall Distribution Patterns-Plan View 2' 4' 6' 8' 10' 12' 14' 16' 18' 20' 22' 24' 26' 28' 0.6m 1.2m 1.8m 2.4m 3.Om 3.7m 4.3m 4.9m 55m 6.1m 6.7m 7.3m 7.9m 8.5m a. • • 2' ` a 0.6 m a a a 4' _... -.- % • 11m • 7psi ....•• ••• 6 • 48 kPa • 1.8m . I • 15 psi 8' �' I 103 kPa II 2A m .. • 10' '�-�'• I 30 psi _�,�,....►""�� r 207 kPa 3.0 m ...... • 12' i 3.7 m .• 14' �.• 4.3 m �.0 • 16' 4.9 m NOTES: A.Data shown is approximate and can vary due to differences in installation. B.These graphs illustrate approximate trajectories,floor-wetting,and wall-wetting patterns for these specific Victaulic FireLock Automatic Sprinklers.They are provided as information for guidance in avoiding obstructions to sprinklers and should not be used as minimum sprinkler spacing rules for installation.Refer to the appropriate NFPA National Fire Code or the Authority Having Jurisdiction for specific information regarding obstructions,spacing limitations and area of coverage requirements.Failure to follow these guidelines could adversely affect the performance of the sprinkler and will void all Listings,Approvals and Warranties. 40.11 2545 Rev.J Updated 07/2014 0 2014 Victaulic Company.All rights reserved. victaulic.com 5 rctaulic victaulic.com I Sprinklers I FireLock®I K5.6, V27 I Publication 40.11 Ratings: Available Wrenches: • All glass bulbs are rated for temperatures from -67°F ( , (-55°C)to those shown in the table below. V27-2 V27 1 Recessed Open End INo escutcheon ✓ ✓ Temperature-°F/°C Maximum With escutcheon ✓ Sprinkler Victaulic Nominal Ambient Glass 111 Temperature Part Temperature Temperature Bulb Classification Identification Rating • Allowed i Color Ordinary 1 A 135°F/57°C 100°F/38°C Orange t • Ordinary 1 C 155°F/68°C 100°F/38°C Red Intermediate E 11750F/790c 150°F/65°C Yellow • Intermediate F l 200°F/93°C 150°F/65°C Green High J 286°F/141°C 225°F/107°C Blue Extra High 7 K 360°F/182°C 300°F/149°C Purple - M Open - No Bulb • ' 7 Standard response only. A WARNING • Always read and understand installation,care,and maintenance instructions,supplied with each box of sprin- • kiers, before proceeding with installation of any sprinklers. • Always wear safety glasses and foot protection. • • Depressurize and drain the piping system before attempting to install,remove,or adjust any Victaulic piping products. • Installation rules,especially those governing obstruction,must be strictly followed. • Painting,plating,or any re-coating of sprinklers(other than that supplied by Victaulic)is not allowed. CO Failure to follow these instructions could result in serious personal injury and/or property damage. The owner is responsible for maintaining the fire protection system and devices in proper operating condition.For minimum maintenance and inspection requirements,refer to the current National Fire Protection Association pam- phlet that describes care and maintenance of sprinkler systems.In addition,the authority having jurisdiction may have additional maintenance,testing,and inspection requirements that must be followed. If you need additional copies of this publication,or if you have any questions about the safe installation of this product,contact Victaulic World Headquarters:P.O.Box 31, Easton,Pennsylvania 18044-0031 USA,Telephone: 001-610-559-3300. rli Installation Note Reference should always be made to the 1-40 Victaulic FireLock Automatic Sprinklers This product shall be manufactured by Victaulic or to Victaulic specifications.All products Installation and Maintenance Sheet for the product you are installing.This installation sheet to be installed in accordance with current Victaulic installation/assembly instructions. is included with each shipment of Victaulic products for complete installation and assembly Victaulic reserves the right to change product specifications,designs and standard data,and is available in PDF format on our website at victaulic.com. equipment without notice and without incurring obligations. Warranty Trademarks Refer to the Warranty section of the current Price List or contact Victaulic for details. Victaulic is a registered trademark of Victaulic Company. III . 40.11 2545 Rev.J Updated 07/2014 ©2014 Victaulic Company.All rights reserved. victaulic.com 6ictaul,c° NCO Worldwide Fire Protection Contacts www.tyco-fire.com • Products Model CC3-4.2 and 5.6 K-factor Combustible Concealed Space Sprinklers Specific Application, Upright General • 60 inch (1524 mm) maximum height from joist to joist and 84 inch (2134 Description mm)from floor to ceiling • 60 inch (1524 mm) maximum height �' . The Model CC3 Combustible Con- for truss and bar joist cealed Sprinklers are quick response, ` upright, specific application sprinklers NOTICE 1 x 1 designed to provide protection of spe- , ;a. cific light hazard combustible, as well The Model CC3 Combustible Con- ‘' as non-combustible,concealed spaces cealed Sprinklers described herein must be installed and maintained in requiring sprinkler protection. The compliance with this document,as well Model CC3 Sprinklers comply with the as with the applicable standards of the criteria for the protection of combus National Fire Protection Association,in tible concealed spaces as described addition to the standards of any other in NFPA 13. authorities having jurisdiction. Failure Physical Characteristics The Model CC3 Sprinklers are designed to do so may impair the performance Frame Brass for installation on BLAZEMASTER of these devices. Button Bronze CPVC wet pipe systems and steel wet Sealing Assembly..Beryllium Nickel w/TEFLON pipe or dry pipe sprinkler systems(refer The owner is responsible for main- Bulb Glass(3 mm) to the respective Design Criteria sec- taining their fire protection system Def etorBronze Compression Screw gB tions). The Model CC3 Sprinklers are and devices in proper operating con- designed to be installed in the follow- dition. Contact the installing contrac4110 - ing arrangements for both wet CPVC for or product manufacturer with any Operation and steel: questions. The glass bulb contains a fluid that • 4.2K Sprinkler expands when exposed to heat.When 14 ft(4,3 m)maximum between the rated temperature is reached, the sprinklers identification fluid expands sufficiently to shatter the glass bulb allowing the sprinkler to acti- 196 ft2(18,2 m2)maximum cover- Number vate and flow water. age area • 5.6K TY2199-Upright,4.2K Design 16 ft(4,9 m)maximum between TY3199-Upright,5.6K sprinklers Criteria Technical ft2(23,8 m2)maximum cover- ■echnical Design criteria is provided as follows: age area Data • 200°F(93°C),Model CC3 Combusti- • 6 inch(152,4 mm)minimum height for ble Concealed Sprinklers with CPVC joist with steel pipe or CPVC when A royals pipe and horizontal slope above insulation filled. 12 inch (305 mm) Uppisted sprinklers not exceeding 2:12 (Refer minimum height for all other arrange- (Listings and approvals only apply to the to Page 2). ments and sizes service conditions indicated in the n Desi g 200°F(93°C),Model CC3 Combusti- Criteria sections.) ble Concealed Sprinklers with steel Maximum Working Pressure pipe and horizontal slope above IMPORTANT 175 psi(12,1 bar) sprinklers not exceeding 2:12 (Refer Always refer to Technical Data Pipe Thread Connection to Page 4). Sheet TFP700 for the "INSTALLER 1/2 inch NPT WARNING" that provides cautions with respect to handling and instal- Discharge Coefficient lation of sprinkler systems and com- K=4.2 gpm/psi'/ (60,5 Ipm/bar'/=) ponents. Improper handling and K=5.6 gpm/psi%(80,6 Ipm/bar%) installation can permanently damage Temperature Rating a sprinkler system or its compo- 200°F(93°C) Ill nents and cause the sprinkler to fail to operate in a fire situation or cause Finish it to operate prematurely. Natural Brass Page 1 of 8 DECEMBER 2016 TFP633 TFP633 Page 2 of 8 • 1-11/16" Use of UL Listed BLAZEMASTER (42,9 mm) CPVC Pipe with Model CC3 6 Sprinklers Components: i 1 "–'— —'—'–" Only BLAZEMASTER CPVC product �,� Ilk may be used in concealed spaces 1 - Frame 5 i SPRINKLER requiring automatic sprinklers, when 2 Sealing ARMS FRAME used in conjunction with Model CC3 Assembly Sprinklers. In order to use the BLAZE- 3 - Button 4 MASTER CPVC product for wood truss 4 - Bulb / 2-1/4" t 7 (57,2 mm) or bar joist construction,the horizontal 5 Compression 3 �.` j run of pipe must be a maximum of 6 Screw t1 WRENCH -� inches (150 mm) above the ceiling or 6 - Deflector 1 noncombustible ceiling insulation, or 7 - Ejection 2 i FLATS 1/3 the depth of concealed space (as Spring measured from the top surface of the 1 1/2" NPT ceiling to the bottom of the deck above), 7/16"(11,1 mm) whichever is smaller(Ref.Figure 2).For NOMINAL MAKE-IN insulation-filled solid wood or compos- FIGURE 1 ite wood joist construction, the hori- MODEL CC3 SPRINKLER zontal run of pipe must be a maximum of 6 inches (150 mm) above ceiling or Maximum Distance Between Model non-combustible ceiling insulation, or Design Criteria, 1/3 the depth of concealed space (as CC3 Sprinklers(CPVC Pipe) measured from the top surface of the CPVC Pipe TY2199 4.2K 14 ft(4,3 m) ceiling to the bottom surface of the Area of Use(CPVC Pipe) TY3199 5.6K 16 ft(4,9 m) joist insulation above), whichever is Horizontal (slope not exceeding 2:12) Maximum Coverage Area smaller(Ref. Figure 3).The CPVC pipe combustible concealed spaces of: (CPVC Pipe) can then be used to supply the Model • Unobstructed wood truss construc- TY2199 4.2K 196 ft2(18,2 m2) CC3 Sprinklers, as well as the sprin- tion or unobstructed bar con- TY3199 5.6K 256 ft2(23,8 m2) klers below the ceiling.Unless modified joistby this technical data sheet, all other struction(Ref. Figure 2). Minimum Distance Between Model guidelines of the "BLAZEMASTER - • • Non-combustible, insulation-filled CC3 Sprinklers(CPVC Pipe) Installation Instructions & Technical solid wood or composite wood joist Minimum sprinkler spacing is 7 ft Manual" must be met. When using 1 construction(Ref.Figure 3). (2,1 m) inch (DN25) or larger pipe, a hanger NOTE: In order to be considered NOTE: Minimum spacing does not must forbplourposdes sathe struai nearest a sprig purposes of restraint. If using "non-combustible insulation-filled apply to any additional sprinklers 3/4 inch (DN19) piping, all sprigs over solid wood or composite wood joist required for protection of CPVC pipe 12 inches (305 mm) must be laterally construction," the insulation (includ- that is offset over an obstruction. braced using methods described in the ing insulation provided with a combus NFPA standards. tible vapor barrier),must completely fill Deflector Position(CPVC Pipe) the pockets between the joists to the • 1 1/2 to 4 inches (40 to 100 mm) Where the CPVC must be offset up bottom of the joists,and the insulation below upper deck for wood truss and over an obstruction and the pipe must be secured in place with metal construction or bar joist construc exceeds the allowed horizontal posi- wire netting. The metal wire netting is tion(Ref. Figure 2) tioning requirements specified above intended to hold the insulation in place • 1-1/2 to 4 inches (40 to 100 mm) as well as shown in Figure 2 and 3, should the insulation become wetted below solid wood or composite wood additional Model CC3 Sprinklers are by the operation of the Model CC3 joists(Ref.Figure 3) to be installed as shown in Figures 2 Sprinklers in the event of a fire. and 3 to protect the BLAZEMASTER Minimum Distance Away From CPVC product. Concealed Space Area(CPVC Pipe) Trusses(CPVC Pipe) The area of the concealed space is not 4-1/2 inches(114 mm) A minimum lateral distance of 18 inches limited;however,for both Figure 2 and (460 mm)must be maintained between Figure 3,where CPVC pipe is being uti Remote Area(CPVC Pipe) m2) the CPVC pipe and heat pumps, fan lized, draft curtains or full height walls The remote area is 1000 ft (93 motors, and heat lamps. must be provided at 1000 ft2 (93 m2) NOTE: The remote area does not areas. This draft curtain shall be at include any additional sprinklers least 1/3 the depth of the concealed required for protection of CPVC pipe space or 8 inches (200 mm), which- that is offset over an obstruction. ever is greater, and be constructed using a material that will not allow heat Required Minimum Density to escape through or above the draft (CPVC Pipe) curtain. 0.10 gpm/ft2(4,1 mm/min) Concealed Space Size(CPVC Pipe) Minimum Operating Pressure The depth of the concealed space is 60 (CPVC Pipe) • inches(1524 mm)maximum to 6 inches 7 psi(0,48 bar) (152 mm)minimum. Obstructions(CPVC Pipe) System Type(CPVC Pipe) See Figure 8 in this data sheet for Light hazard,wet pipe system obstructions rules. TFP633 Page 3 of 8 MODEL CC3 4-1/2"(114 mm)MINIMUM • � UPPER DECK - FROM FACE OF WOOD TRUSS SPRINKLER OR TOP CHORD OF BAR JOIST 6"(152 mm MAXIMUM FOR 4"(102 Omm) —V ` CPVC PIPE OR LESS �J r 1 FRAME ARMS OF 4"(102 mm) SPRINKLER MUST MAXIMUM t \ BE SE WITH INSTALLED IN-LINE 1-1/2"(40 mm) MINIMUM PIPE RUN L J 6"(152 mm) 60"(1524 mm) OBSTRUCTION TOP OF CHORD MINIMUM MAXIMUM I . �` H CEILING / X ,„,„„„„„„,„,„,„„,„: . „„„ , „„„, \ 6"(152 mm)MAXIMUM ABOVE WHEN OFFSETTING CPVC PIPE OVER AN CEILING TO BOTTOM OF PIPE OR BOTTOM OBSTRUCTION,A MODEL CC3 SPRINKLER NON-COMBUSTIBLE CEILING INSULATION, OF PIPE MUST BE INSTALLED DIRECTLY ON THE OR 1/3 THE DEPTH OF CONCEALED SPACE CPVC PIPE OVER THE OBSTRUCTION (AS MEASURED FROM TOP SURFACE OF CEILING TO BOTTOM OF DECK ABOVE), WHICHEVER IS SMALLER FIGURE 2 UNOBSTRUCTED WOOD TRUSS CONSTRUCTION OR UNOBSTRUCTED BAR JOIST CONSTRUCTION CROSS SECTION ELEVATION VIEW CPVC PIPE UPPER COMPOSITE SOLID WOOD NON-COMBUSTIBLE 0 DECK WOOD JOISTS JOISTS INSULATION 4"(102 mm) MAXIMUM rear rl_�r 1'MT" i r \L' -10. y T , r 1-1/2"(40 mm) MINIMUM 6"(152 mm) "PI...411 ►/� '\ 1 MAXIMUM FOR CPVC PIPE --1 MODEL CC3 '--- SPRINKLER iX FRAME ARMS OF , I I SPRINKLER MUST 60"(1524 mm) BE INSTALLED MAXIMUM IN-LINE WITH 72"(1829 mm) \ MAXIMUM 6"(152 \ PIPE RUN MINIMUM L OBSTRUCTION \ J CEILING \ X X TOP OF 6"(152 mm)MAXIMUM ABOVE CHORD WHEN OFFSETTING CPVC PIPE OVER AN CEILING TO BOTTOM OF PIPE OR OBSTRUCTION,A MODEL CC3 SPRINKLER NON-COMBUSTIBLE CEILING INSULATION, BOTTOM MUST BE INSTALLED DIRECTLY ON THE OR 1/3 THE DEPTH OF CONCEALED SPACE OF PIPE CPVC PIPE OVER THE OBSTRUCTION (AS MEASURED FROM TOP SURFACE OF CEILING TO BOTTOM SURFACE OF JOIST INSULATION ABOVE), WHICHEVER IS SMALLER FIGURE 3 NON-COMBUSTIBLE INSULATION-FILLED UPPER DECK SOLID WOOD OR COMPOSITE WOOD JOIST CONSTRUCTION CROSS SECTION ELEVATION VIEWIII CPVC PIPE TFP633 Page 4 of 8 ! Design Criteria, • For solid wood joist construction System Type(Steel Pipe) Steel Pipe (Ref. Figure 5)and obstructed wood Light hazard,wet or dry pipe system truss construction(Ref. Figure 7): NOTES: Use of the 4.2K sprinklers in Area of Use(Steel Pipe) Blocking must be provided in each dry pipe systems is permitted by section Horizontal (slope not exceeding 2:12) upper deck and ceiling joist channel 8.3.4.4 of NFPA 13 (2013 edition) where combustible concealed spaces of: at a maximum 32 ft(9,75 m)inter- piping is corrosion resistant or internally vals.This blocking shall be installed galvanized. • Unobstructed wood truss construc- to the full depth of the joists and be tion or unobstructed bar joist con- installed so as to not allow heat to Maximum Distance Between Model struction(Ref. Figure 4) escape through or above the block- CC3 Sprinklers(Steel Pipe) • Solid wood joist construction (Ref. ing.The blocking must be con- TY2199 4.2K 14 ft(4,3 m) Figure 5)where the upper deck and structed using a non-combustible TY3199 5.6K 16 ft(4,9 m) material or the joist construction ceiling joists may have a maximum material. Maximum Coverage Area(Steel depth of 12 inches(300 mm)and typ- Pipe) ical on center joist spacing of mini- Draft curtains must protrude below TY2199 4.2K 196 ft2(18,2 m2) mum 16 inches(400 mm) the joist a minimum of 6 inches(150 mm)or 1/3 the depth of the con- TY3199 5.6K 256 ft2(23,8 m2) • Non-combustible insulation-filled cealed space,whichever is greater, Minimum Distance Between Model solid wood joist or wood composite and run parallel with the joist CC3 Sprinklers(Steel Pipe) joist construction(Ref. Figure 6) spaced at 31 ft(9,4 m)width maxi Minimum sprinkler spacing is 7 ft • Obstructed wood truss construction mum to limit the area to a maximum (2,1 m) (Ref. Figure 7) of 1000 ft2(93 m2).The draft cur- tains are to be constructed using a Deflector Position(Steel Pipe) NOTE:In order to be considered"non- material that will not allow heat to 1-1/2 to 4 inches(40 to 100 mm)below combustible insulation-filled solid escape through or above the draft upper deck for wood truss construction wood joist or composite wood joist curtain. or concealed spaces of non-combusti- construction", the insulation (includ- • For non-combustible,insulation-filled ble bar joist construction(Ref.Figure 4) ing insulation provided with a combus- solid wood joist or composite wood 1-1/2 to 2 inches40 to 50 mm) below tible vapor barrier),must completely fill joist construction(Ref. Figure 6),the solid wood joist Ref. Fi ure 5or top the pockets between the joists to the requirement for draft curtains and chord of a ood truss that has a de th bottom of the joists,and the insulation blocking does not apply. p must be secured in place with metal greater than 4 inches(Ref. Figure 7) wire netting. The metal wire netting is Concealed Space Size(Steel Pipe) 1-1/2 to 4 inches(40 to 100 mm)below 411 intended to hold the insulation in place The minimum and maximum concealed non-combustible insulation filled solid should the insulation become wetted space depth is as follows: wood joists or composite wood joists by the operation of the Model CC3 For unobstructed wood truss construc- (Ref. Figure 6) Sprinklers in the event of a fire. tion or concealed spaces of unob- Remote Area(Steel Pipe) Concealed Space Area(Steel Pipe) structed bar joist construction (Ref. The remote area for wood truss con- The area of the concealed space is not Figure 4) the maximum depth of the struction or bar joist construction(Ref. limited; however, concealed space is 60 inches (1524 Figure 4),solid wood joist construction • For unobstructed wood truss con- mm)from bottom of upper deck to top (Ref. Figure 5), or obstructed wood of ceiling, and the minimum depth is truss construction (Ref. Figur poe is strn uction combust concealedor le, supacesbof of 6 inches (152 mm)from the bottom of 1000 ft2(93 m2)for wet pipe r dry pipe the upper chords to the top of the lower stems. joist construction(Ref.Figure 4)draft chords. systems. curtains or full height walls must be The remote area for non-combusti- provided at 1000 ft2 (93 m2) areas. For solid wood joist construction ble insulation-filled solid wood joist This draft curtain shall be at least 1/3 (Ref. Figure 5)and solid wood or com- or wood composite joist construction the depth of the concealed space posite wood joist construction the (Ref. Figure 6)without draft curtains is or 8 inches (200 mm), whichever is maximum depth of the concealed to be calculated per the requirements greater, and be constructed using space is 84 inches (2134 mm) from of NFPA 13. a material that will not allow heat to bottom of upper deck to top of ceiling, escape through or above the draft and the minimum depth is 6 inches(152 Required Minimum Density curtain. mm)from the bottom of the upper deck (Steel Pipe) joists to the top of the ceiling joists. If 0.10 gpm/ft2(4,1 mm/min) joist construction is filled with non- Minimum Operating Pressure combustible insulation the maximum (Steel Pipe) height of the space is 84 inches(2134 7 psi(0,48 bar) mm)(Ref. Figure 6). For obstructed wood truss construction Obstructions(Steel Pipe) (Ref. Figure 7), the maximum depth of See Figure 8 in this data sheet for the concealed space is 84 inches(2134 obstructions rules. mm)from bottom of upper deck to top of ceiling, and the minimum depth is 6 inches (152 mm)from the bottom of • the upper chord to the top of the lower chord. TFP633 Page 5 of 8 MODEL CC3 4-1/2"(114 mm)MINIMUM • UPPER DECK —\ --.— FROM FACE OF WOOD TRUSS SPRINKLER OR TOP CHORD OF BAR JOIST \ JISI --\ d t 4"(102 mm) TOP CHORD MAXIMUM 4"(102 mm) 1-1/2"(40 mm) OR LESS r ' MINIMUM 60"(1524 mm) FRAME ARMS OF MAXIMUM SPRINKLER MUST P in r BE INSTALLED IN-LINE WITH 6"(152 mm) PIPE RUN L J MINIMUM CEILING — FIGURE 4 UNOBSTRUCTED WOOD TRUSS CONSTRUCTION OR UNOBSTRUCTED BAR JOIST CONSTRUCTION CROSS SECTION ELEVATION VIEW STEEL PIPE r 1FRAME ARMS OF SPRINKLER i UPPER 2x FLOOR SOLID MUSTE WITHBE INSTALLED D I � IN-LINE PIPE RUN : D/ECK WOOD JOISTS411/ Il' L k \( i 84"(2134 mm) MAXIMUM MODEL CC3 T SPRINKLER 60" (1524 mm) u u 1 Iiia MAXIMUM 2"(51 mm) I I 6"(152 mm) MINIMUM MAXIMUM 1-112"(38 mm) 'III f • MINIMUM I 1 1ri 1 I CEILING CEILING FRAMING FIGURE 5 SOLID WOOD JOIST CONSTRUCTION CROSS SECTION ELEVATION VIEW STEEL PIPE TFP633 Page 6 of 8 • r 1 FRAME ARMS OF SPRINKLER j UPPER MUST BE INSTALLED i NON-COMBUSTIBLE � IN-LINE WITH PIPE RUN I DECK INSULATION L J Iir4 tiT♦T►�T♦T • 197- r 10-10 84" MI Mi Jk 2134 mm MAXIMUM ) COMPOSITE MODEL CC3 2x FLOOR SOLID T WOOD JOISTS SPRINKLER 1,iWOOD JOISTS 60"(1524 mm) 4 a iii-I_'iiimm MAXIMUM 4"(102 mm) I 6"(152 mm) MAXIMUMI MINIMUM 1-1/2"(38 mm) , .....01 . . r% . " MINIMUM 1 "-1 . 1 i CEILING CEILING FRAMING FIGURE 6 NON-COMBUSTIBLE INSULATION-FILLED UPPER DECK SOLID WOOD OR COMPOSITE WOOD JOIST CONSTRUCTION CROSS SECTION ELEVATION VIEW STEEL PIPE r• 1 1 FRAME ARMS OF SPRINKLER I MUST BE INSTALLED i UPPER TOP CHORD GREATER I IN-LINE WITH PIPE RUN DECK THAN 4"(102 mm)IN DEPTH L J 7== d Y Y T/ U MODEL CC3 84"(2134 mm) SPRINKLER ] i•i J MAXIMUM 2"(51 mm) 60"(1524 mm) MAXIMUM MAXIMUM 1-1/2"(38 mm) 6"(152 mm) MINIMUM MINIMUM Cf!--4L-----7--- ,---7°( )—( YCEILING CEILING FRAMING FIGURE 7 OBSTRUCTED WOOD TRUSS CONSTRUCTION CROSS SECTION ELEVATION VIEW STEEL PIPE I TFP633 Page 7 of 8 Distance from Maximum Allowable G. 1111 UPPER DECK Centerline of Distance of Deflector OR BOTTOM OF Sprinkler to Side Above Bottom of NON-COMUSTIBLE of Obstruction Obstruction WRENCH RECESS INSULATION (A) (B) (USE END"A" 0" t <12''<(304,8 mm) (0 mm) 571. ONLY) B 7---MODEL CC3 12"to<18" 2-1/2" ■� SPRINKLER (304,8 mm to<457,2 mm) (63,5 mm) FIGURE 9 18"to<24" 3-1/2" W-TYPE 6 SPRINKLER (457,2 mm to<609,6 mm) (88.9 mm) WRENCH f A—_..– 24"to<30" 5-1/2" (609,6 mm to<762,0 mm) (139,7 mm) OBSTRUCTION 30"to<36" 7-1/2" Installation (762,0 mm to<914,4 mm) (190,5 mm) NOTE: 36"to<42" 9-1/2" The Model CC3 WEB MEMBERS AND GUSSETS (914,4 mm to<1066,8 mm) (241,3 mm) Sprinklers withhst this accordance be installed in SHALL NOT BE CONSIDERED 42"to<48" 12" section. OBSTRUCTIONS PROVIDED THE (1066,8 mm to<1219,2 mm) (304,8 mm) MINIMUM 4-1/2 INCH LATERAL 48"to<54" 14" General Instructions DISTANCE(FIG.2)REQUIRED (1219,2 mm to<1371,6 mm) (355,6 mm) The Model CC3 Sprinklers are to be BY THE SPECIFIC APPLICATION 54"to<60" 16-1/2" installed upright and with their frame LISTING IS MAINTAINED. (1371,6 mm to<1524,0 mm) (419,1 mm) arms (Ref. Figure 1) in-line with the pipe run (Ref. Figures 2 through 7, as applicable). A>_3C or 3D Do not install any bulb type sprinkler UPPER As24"(609,6 mm) if the bulb is cracked or there is a loss DECK (Use dimension C or D,whichever is greater) of liquid from the bulb. With the sprin- OBSTRUCTION OBSTRUCTION kler held horizontally,a small air bubble MODEL CC3 should be present.The diameter of the A"--1-7 SPRINKLER air bubble is approximately 1/16 inch (1,6 mm)for the 200°F(93°C)tempera- C MODEL CC3 C \�`\ 1 ture rating. SPRINKLER �" A leak-tight 1/2 inch NPT sprinkler joint should be obtained with a torque of 7 to D —i D ---A-- - 14 ft.-lbs.(9,5 to 19,0 Nm).Higher levels • LOWER of torque may distort the sprinkler inlet DECK with consequent leakage or impairment ,,,,„„„,,,,,,<,,,,,,,,,,,,,,,,„,,,,,,,, of the sprinkler. The Model CC3 Sprinklers must only ELEVATION VIEW PLAN VIEW be installed in the upright position with FIGURE 8 the deflector parallel to the upper deck. NFPA 13 OBSTRUCTION TO WATER DISTRIBUTION CRITERIA With pipe thread sealant applied to the (REFERENCE) pipe threads, use only the W-Type 6 (End A) Sprinkler Wrench (Ref. Figure 9) for installation of the Model CC3 Sprinklers by applying the wrench to the sprinkler wrench flats only. TFP633 Page 8 of 8 • Care and Limited Ordering Maintenance Warranty Procedure The Model CC3 Sprinklers must be For warranty terms and conditions,visit Contact your local distributor for avail- maintained and serviced in accordance www.tyco-fire.com. ability.When placing an order,indicate with this section. the full product name and Part Number Before closing a fire protection system (P/N). main control valve for maintenance Sprinkler Assemblies with NPT work on the fire protection system that Thread Connections it controls,permission to shut down the Specify: SIN (specify), K-factor affected fire protection systems must (specify), Model CC3 Combustible be obtained from the proper authorities Concealed Space Sprinkler, Specific and all personnel who may be affected Application, Upright, 200°F (93°C), by this action must be notified. P/N (specify): Sprinklers that are found to be leaking TY2199,4.2K 51-311-1-200 or exhibiting visible signs of corrosion TY3199,5.6K 51-301-1-200 must be replaced. Sprinkler Wrench: Automatic sprinklers must never be Specify: W-Type 6 Sprinkler Wrench, painted, plated, coated, or other- P/N 56-000-6-387 wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated,should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid damage to the sprinklers before, • during, and after installation. Sprin- klers damaged by dropping, striking, wrench twist/slippage,or the like,must be replaced. Also, replace any sprin- kler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installa- tion Section). The owner is responsible for the inspection,testing,and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Association (e.g., NFPA 25), in addition to the stan- dards of any other authorities having jurisdiction.Contact the installing con- tractor or sprinkler manufacturer with any questions. It is recommended that automatic sprinkler systems be inspected,tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and/or national codes. • GLOBAL HEADQUARTERS I 1400 Pennbrook Parkway,Lansdale,PA 19446 I Telephone+1-215-362-0700 Copyright©2016 Tyco Fire Products,LP. All rights reserved. tqC® TEFLON is a registered trademark of DuPont, Fire Protection Products BLAZEMASTER is a trademark of The Lubrizol Corporation Eddy Flow • The Cost Effective Replacement for Schedule 10 Realizing the growing need of fire protection systems for roll grooving and welding. Please check with in commercial and residential construction, Bull appropriate sources for up-to-date listings and Moose Tube has added Eddy Flow to its approval information. comprehensive line of sprinkler pipe products. As an added benefit, it is more economical to use than Eddy Flow is a specially engineered replacement for schedule 10 due to reduced delivery costs and ease schedule 10, offering better flow characteristics while of handling. Furthermore, Eddy Flow's larger ID providing design flexibility. This product is FM provides an opportunity for downsizing and further approved, as well as UL listed (for U.S. and Canada) cost savings. COMPARISON Inside Diameter C.R.R.* NPS O.D. Eddy Flow Sch. 10 Sch. 40 Eddy Flow Schedule 40 (in) (in) (in) (in) (in) 1-1/4 1.660 1.515 1.442 1.380 2.93 1.00 1-1/2 1.900 1.734 1.682 1.610 3.44 1.00 III 2 2.375 2.209 2.157 2.067 2.78 1.00 2-1/2 2.875 2.729 2.635 2.469 1.09 1.00 3 3.500 3.342 3.260 3.068 1.00 1.00 4 4.500 4.316 4.260 4.026 1.00 1.00 * Corrosion Resistance Ratio BENEFITS Dual Certified to ASTM A135 and A795. FM approved for roll grooving and welding for use in wet systems. ' UL listed(for U.S.and Canada)for joining by welding or by listed rubber gasketed fittings for use in wet,dry, preaction,and deluge type sprinkler systems. Lightweight-saves shipping costs,and offers easier handling. " Can be used with roll grooved couplings or welded outlets for pressures up to 175 psi. Floor stock available in various lengths produced in Trenton(GA),Gerald(MO),and Masury(OH).Also can be ordered in custom lengths. Can be supplied roll grooved,or plain end for use with Victaulic'Flf Fittings. Can be used for wet and dry"systems. *Eddy Flow can be hot dipped galvanized to meet FM's requirement for dry systems. PIPE PREPARATION For proper operation,all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket,pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint,scale,dirt,chips,grease,and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly,causing leakage. Also,check the manufacturer's instructions for the specific fitting used. 1819 Clarkson Road For contact additionalurinformation, ° Q �� Chesterfield, MO 63017 your salesperson today at III�moose rum COMPA fwtY (800)325-4467(21113 (800)325 4467 or(636)537-2600 FAX:(636)537-2645 in the USA,or from Canada wwwcall( )882-4666 4411: ilb A(CTEW company e-mail:info(aibullmoosetube.com APPROVED All information contained herein is accurate as known at the time of publication. Bull Moose Tube reserves the right to change product specifications without notice and without incurring obligation. 0/07 • Schedule 10 and Schedule 40 FM Approved and UL Listed Sprinkler Pipe Bull Moose Tube Company is a recognized producer Bull Moose Tube's Sch. 10 and Sch. 40 pipes are of quality pipe products. Our Schedule 10 and made to ASTM A135 and ASTM A795. These Schedule 40 are FM Approved and UL Listed (for U.S. products are typically supplied with our protective and Canada), even though these products do not coating but can be supplied without the coating so require separate approvals and listings. Bull Moose they can be hot-dip galvanized to meet FM Tube made the decision to have them approved and requirements for use in dry systems in accordance listed for your peace of mind. Our Sch. 10 and Sch. 40 with the zinc coating specifications of ASTM A795 or have been through the same rigorous testing as our ASTM A53. other fine pipe products. Schedule 10 Pipe Nominal Pipe Size O.D. l.D. Nom. Wall Weight/Ft Bundle (in) (in) (in) (in) Size 1 1.315 1.097 0.109 1.40 lbs/ft 61 1-1/4 1.660 1.442 0.109 1.81 lbs/ft 37 • 1-1/2 1.900 1.682 0.109 2.08 lbs/ft 37 2 2.375 2.157 0.109 2.64 lbs/ft 37 2-1/2 2.875 2.635 0.120 3.53 lbs/ft 37 3 3.500 3.260 0.120 4.33 lbs/ft 24 4 4.500 4.260 0.120 5.62 lbs/ft 19 Schedule 40 Pipe Nominal Pipe Size O.D. I.D. Nom.Wall Weight/Ft Bundle (in) (in) (in) (in) Size 1 1.315 1.049 0.133 1.68 lbs/ft 61 1-1/4 1.660 1.380 0.140 2.27 lbs/ft 37 1-1/2 1.900 1.610 0.145 2.72 lbs/ft 37 2 2.375 2.067 0.154 3.65 lbs/ft 37 PIPE PREPARATION For proper operation,all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket,pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint,scale,dirt,chips,grease,and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly,causing leakage. Also,check the manufacturer's instructions for the specific fitting used. • Q1/ 6 1819 Clarkson Road For additional information, g UL US Chesterfield,MO 63017 contact your salesperson today at II BULL MOOSE TUEM COMPANY (800)325-4467 (800)325-4467 or(636)537-2600 TED FAX:(636)537-2645 in the USA,or from Canada www.bullmoosetube.com call(800)882-4666 4:111> ACMOcompany e-mail:info(caullmoosetube.com APPROVED All information contained herein is accurate as known at the time of publication. Bull Moose Tube reserves the right to change product specifications without notice and without incurring obligation. 06/01 Eddythread 40 • A Lightweight Schedule 40 Replacement Pipe That Has a Corrosion Resistance Ratio of 1.0 Bull Moose Tube Company has been making pipe for a long time and is recognized as a producer of quality pipe products. Eddythread 40 is designed with the same thoroughness as our other fine pipe products and now our customers have an option to buy a carefully designed replacement for Schedule 40 that: • Has a Corrosion Resistance Ratio of 1.0 • Has a Pressure Rating of 300 psi • Is Lighter Weight Than Schedule 40 • Is Approved by Factory Mutual and Listed by Underwriters Laboratories • Is Produced in Accordance to ASTM A-135 and A-795 • Can be Used With Standard Schedule 40 Threaded Fittings, Couplings and Valves • Is Produced From Steel With Excellent Properties of Strength and Threadability • Can be Used in Wet, Dry, Preaction, and Deluge Type Sprinkler Systems* • Offers Lower Freight Costs EDDYTHREAD 40 SPECIFICATIONS III 4,..24;,_ ,,,- #./..: NOMINAL PIPE SIZE(in) WEIGHT Ibs!ft I.D. (in) BU� i 1 1.461 1.083 70 1 1/4 2.070 1.418 51 1 1/2 2.547 1.654 44 2 3.308 2.123 30 CORROSION RESISTANCE RATIOS "`'" i +fin +Y F'e�cr r i nnl irr�,u r en I is` .2.. a '."V t,y> # .0-.) SC1 IL.DULL.4V �. . ., .-.=..,,�*a?.Y'.'ur..,.au,ir'3'.k r.�� .� hs w.�F:'�FZ,a. 4.tiP* 1 1.00 1.00 1 1/4 1.00 1.00 1 1/2 1.00 1.00 2 1.00 1.00 *Eddythread 40 can be hot dipped galvanized to meet FM's requirement for dry systems 1819 Clarkson Road For additional information, (..?338 Chesterfield,MO 63017 contact your salesperson today at CUL us IA BULL MOOSE E COIVIRANY (800)325-4467 (800)325-4467 or(636)537-2600 LISTEDFAX:(636)537-2645 in the USA,or from Canada www.bullmoosetube.com call(800)882-4666 41: III A(CiPFIRO company e-mail:sales(cr�,bullmoosetube.com APPROVED All information contained herein is accurate as known at the time of publication. Bull Moose Tube reserves the right to change product specifications without notice and without incurring obligation. 8/08 • fill11711Mmorsium;AIRal FlameGuard ® CPUC FIRE SPRINKLER PIPING PRODUCTS „^` TII, :* . w TECHNICAL INFORMATION WEIGHTS & DIMENSIONS • No v m Aber2 7 e SUPERSEDES ALL PREVIOUS EDITIONS _pc-3441.1r-LN :Ai wvpCTURIAtc Ny ate V N, A z-4 t 4J969j i') oCE...fit t 444Rs GAU D LPCB °O � 2 i UKAS s 0 '- a MAS S ,��° oo Visit our web site: 0assessed to iso 9001:2008 ,, ��www.spearsmfg.com` FG-4-1115 Certificate number 293 SPEARS FlameGuard® CPVC FIRE SPRINKLER PIPING PRODUCTS • The information contained in this section is based on current information and Product design at the time of publication and is subject to change without notification.Our ongoing commitment to product improvement may result in some variation.No representations,guarantees or warranties of any kind are made as to its accuracy,suitability for particular applications or results to be obtained therefrom.For verification of technical data or additional information not contained herein,please contact Spears®Technical Services Department[West Coast:(818)364-1611—East Coast:(678)985-1263]. General Information RECOMMENDATIONS FOR INSTALLERS AND USERS: Plastic piping systems should be ENGINEERED, INSTALLED and OPERATED in accordance with ESTABLISHED DESIGN AND ENGINEERING STANDARDS AND PROCEDURES for plastic piping systems.Suitability for the intended service application should be determined by the installer and/or user prior to installation of a plastic piping system.All Installation and maintenance personnel should be trained in the proper handling and installation requirements and precautions of plastic piping systems. PRIOR TO ASSEMBLY,all piping system components should be inspected for damage or irregularities.Mating components should be checked to assure that tolerances and engagements are compatible.Do not use any components that appear irregular or do not fit properly.Contact the appropriate manufacturer of the component product in question to determine usability.Consult all applicable codes and regulations for compliance prior to installation. Installation must be made in accordance with Spears®Manufacturing Company FlameGuard®CPVC Fire Sprinkler Piping Products Installation Instructions-FG-3 NOTE—Individual or group instruction in correct solvent welding procedures is available by contacting your local distributor or your servicing Spears"Regional Distribution Center. SOLVENT CEMENT CONNECTIONS — Spear? Manufacturing Company recommends the use of Spears® FS-5 One Step solvent cement for joining Spears® products. Use of solvent cementing products not approved for CPVC fire sprinkler systems, or failure to follow installation instructions will automatically void the warranty. THREADED CONNECTION—Spears®Manufacturing Company recommends the use of Spear?BLUE 75'm Thread Sealant.This product has been tested by Spears° and the sealant manufacturer for compatibility with the Spears®CPVC fire sprinkler products.Consult the sprinkler head manufacturer before using this product.WARNING: OTHER PIPE JOINT COMPOUNDS OR PASTES MAY CONTAIN SUBSTANCES THAT COULD CAUSE STRESS CRACKING IN THE CPVC OR OTHER FITTING COMPONENTS.Care must be taken to avoid over torquing-generally 1 to 2 turns beyond finger tight is all that is required to make up a threaded connection.Factory testing has indicated 10-25 ft.lbs.of torque is adequate to obtain a leak free seal. GASKET SEALED THREAD CONNECTIONS—This type of connection can only be made with Spears® TorqueSafeT"",SofTorqueT"^or OuickTorqueT""style Gasket Sealed Female Sprinkler Adapters. DO NOT USE ANY TYPE OF THREAD SEALANT WHEN INSTALLING THIS TYPE OF ADAPTER.Tape or paste may impair proper sealing • and function.Testing has shown that hand tight until snug for the TorqueSafe'"'adapter and finger tight plus 1-turn is all that is needed to seal this special connection. Sprinkler heads in these specialty fittings can then be additionally tightened clockwise to bring sprinkler frames into desired alignment without stressing the fitting. See specific adapter instructions in package for details. GripLocT'CONNECTIONS—This type of connection can only be made with Spears®GripLocrm Couplings or Repair Couplings. DO NOT USE ANY TYPE OF SOLVENT CEMENT OR SEALANT WHEN INSTALLING THIS TYPE OF CONNECTION. Uses an internal stainless steel gripper ring with an internal elastomer gasket seal. Connection allows immediate system use.See specific instructions in package for details. Installation Training Available-Contact Spears®Technical Services for Details FlameGuard®Products must be installed in accordance with Spear?FlameGuard®CPVC Fire Sprinkler Piping Products Installation Instructions,National Fire Protection Association Standards 13,13R,13D,and in accordance with local codes.Code requirements and field conditions may differ. It is the responsibility of the installing contractor to insure that the product is suitable to meet these requirements. Dimension Reference G = (LAYING LENGTH)Intersection of center lines to bottom of socket/thread;90°elbows,tees, crosses;±1/32 inch. M = Outside diameter of socket/thread hub;±1/16 inch. H = Intersection of center lines to face of fitting;90°elbows tees,crosses;±1/32 inch. N = Socket bottom to socket bottom;couplings;±1/16 inch. J -= Inleisectiun of center lines to bottom of sucket/tliread,45'elbows, 1/32 inch 0 = Width of flats;±1/16 inch. - L = Overall length of fittings;±1/16 inch. W= Height of cap;±1/16 inch. CPVC FIRE SPRINKLER PIPE SDR 13.5(ASTM F 442) Part Number Nominal Size Average O.D. Average I.D. Pp Weight Approx.Wei ht Lbs./Ft. Inches (mm) Inches (mm) Inches (mm) CP-007 3/4 (19.1) 1.050 (26.7) .874 (22.5) 0.168 CP-010 1 (25.4) 1.315 (33.4) 1.101 (28.2) 0.262 CP-012 1-1/4 (31.8) 1.660 (42.2) 1.394 (35.6) 0.418 CP-015 1-1/2 (38.1) 1.900 (48.3) 1.598 (40.7) 0.548 CP-020 2 (50.8) 2.375 (60.3) 2.003 (50.9) 0.859 CP-025 2-1/2 (63.5) 2.875 (73.0) 2,423 (61.5) 1.257 CP-030 3 (76.2) 3.500 (88.9) 2.950 (75.0) 1.867 'Lead Free"low lead certification-unless other wise specified,all Spears®FlameGuard"fittings specified here-in are certified by NSF International to ANSI/NSF.Standard 61, IP Annex G and is in compliance with California's Health&Safety Code Section 116825(commonly known as AB1953)and Vermont Act 193.Weighted average lead content<=0.25%. Spears"PVC and CPVC Pipe,Fittings and Valves have always been lead-free and Certified by NSF International for use in potable water systems.Spears®offers a wide range of lead-free specialty fittings and transition adapters for plumbing applications.However,certain brass threaded adapter fittings for applications that are not intended to convey water for human consumption through drinking or cooking are still produced and available. 1 SPEARS®MANUFACTURING COMPANY • ( FlameGuard® CPVC FIRE SPRINKLER PIPING PRODUCTS SPEARS SOCKET DIMENSIONS SCH 40-ASTM F438 I~C--..-1 SCH 80 ASTM F439 t B A im(im Size Socket Socket Tolerance SCH 40 Minimum SCH 80 Minimum Entrance A Bottom B Socket Length C Socket Length C 314 1.058 1.046 ±.004 .719 1.000 1 1.325 1.130 ±.005 .875 1.125 1-1/4 1.670 1.655 ±.005 .938 1.250 1-1/2 1.912 1.894 ±.006 1.094 1.375 2 2.387 2.369 ±.005 1.156 1.500 2-1/2 2.889 2.868 ±.007 1.750 1.750 3 3.516 3.492 ±.008 1.875 1.875 TEE Socket x Socket x Socket 1-�� I L I • L--i -- f- L -.- Part Number Size G H L M Approx.Wt.(Lbs.) 4201-007 3/4 9/16 1-1/2 2-31/32 1-5/16 .11 4201-010 1 7/8 1-13/16 3-5/8 1-5/8 .20 4201-012 1-1/4 15/32 2-3/32 4-7/32 2 .29 4201-015 1-1/2 1-5/32 2-9/16 5-3/32 2-11/32 .54 4201-020 2 1-13/32 2-15/16 5-7/8 2-7/8 .86 4201-025 2-1/2 1-23/32 3-1/2 7 3-15/32 1.62 4201-030 3 2-1/16 3-31/32 7-15/16 4-5/32 2.53 REDUCING TEE F. I M, Socket x Socket x Socket _JUL_� f I H, 4 G1 G G21 "..--H ---H2- • L Part Size G G1 G2 H H1 H2 L M M1 M2 Approx. Number Wt.(Lbs.) 4201-102 3/4x3/4x1 3/4 3/4 3/4 1-11/16 1-25/32 1-11/16 3-13/32 1-5/16 1-21/32 1-5/16 .13 4201-125 1x3/4x3/4 23/32 7/8 23/32 1-25/32 1-13/16 1-21/32 3-7/16 1-19/32 1-11/32 1-5/16 .16 III 4201-126 1x3/4x1 23/32 23/32 3/4 1-27/32 1-27/32 1-3/4 3-19/32 1-5/8 1-5/8 1-5/16 .17 4201-131 1x1x314 11/16 13/16 11/16 1-13/16 1-13/16 1-13/16 3-5/8 1-5/8 1-5/16 1-5/8 .17 4201-157 1-1/4x1x3/4 11/16 1-1/32 11/16 1-15/16 2-1/32 1-13/16 3-25/32 2-3/32 1-13/32 1-23/32 .32 MADE IN THE U.S.A. 2 SPEARS FlameGuard® CPVC FIRE SPRINKLER PIPING PRODUCTS • REDUCING TEE (continued) 1-01-mi Socket x Socket x Socket t —1vi-� f _I M2 HIIt G1 G NMI G2 --H -.—H2—P- L H2--L r- Part Number Size G G1 G2 H H1 H2 L M M1 M2 Approx.Wt.(Lbs.) 4201-158 1-1/4x1x1 27/32 29/32 25/32 2-1/16 2-1/32 1-29/32 3-15/16 1-31/32 1-5/8 1-5/8 .24 4201-159 1-1/4x1 x1-1/4 31/32 31/32 31/32 2-7/32 2-7/32 2-3/32 4-11132 2-1/8 2-1/8 1-23/32 .36 4201-167 1-1/4x1-1/4x314 21/32 1 21/32 1-29/32 2 1-29/32 3-13/16 2 1-5/16 2 .22 4201-168 1-1/4x1-1/4x1 13/16 1 13/16 2-1/16 2-1/8 2-1/16 4-1/8 1-31/32 1-21/32 1-31/32 .24 4201-169 1-114x1-1/4x1-1/2 1-1/8 15/16 1-1/8 2-3/8 2-11/32 2-3/8 4-3/4 2-3132 2-11/32 2-3/32 .51 4201-201 1-1/2x1-1/4x3/4 11/16 1 1/4 2-1/16 2 1-15/16 4 2-5/16 1-3/8 2-1/16 .41 4201-202 1-1/2x1-1/4x1 27/32 1-1/32 1 2-7/32 2-5/32 2-1/4 4-15/32 2-5/16 1-11/16 2-1/16 .42 4201-210 1-1/2x1-1/2x3/4 11/16 1-1/32 11/16 2-1/16 2-1/32 2-1/16 4-5/32 2-11/32 1-13/32 2-11/32 .39 4201-211 1-1/2x1-1/2x1 13/16 1-3/32 13/16 2-3/16 2-1/4 2-3/16 4-3/8 2-11/32 1-3/4 2-11/32 .41 4201-212 1-1/2x1-1/2x1-1/4 1-1/32 1-3/32 1-1/32 2-13/32 2-11/32 2-13/32 4-13/16 2-11/32 2-1/8 2-11/32 .49 4201-213 1-1/2x1-1/2x2 1-9/32 1-5/32 1-9/32 2-21/32 2-21/32 2-21/32 5-11/32 2-11/32 2-29/32 2-11/32 .64 4201-248 2x2x3/4 11/16 1-13/32 11/16 2-7/32 2-7/16 2-7/32 4-7/16 2-27/32 1-3/8 2-27/32 52 4201-249 2x2x1 27/32 1-13/32 27/32 2-11/32 2-9/16 2-11/32 4-23/32 2-7/8 1-3/4 2-7/8 58 4201-250 2x2x1-1/4 1-1/32 1-11/32 1-1/32 2-17/32 2-19/32 2-17/32 5-3/32 2-7/8 2-3/32 2-7/8 .65 4201-251 2x2x1-1/2 1-5/32 1-7/16 1-5/32 2-11/16 2-13/32 2-11/16 5-3/8 2-7/8 2-13/32 2-7/8 .79 4201-289 2-1/2x2-1/2x1 27/32 1-23/32 27/32 2-5/8 2-27/32 2-5/8 5-1/4 3-17/32 1-23/32 3-17/32 1.01 4201-290 2-1/2x2-1/2x1-1/4 1-3/32 1-23/32 1-1/32 2-13/16 2-31/32 2-13/16 5-21/32 3-9/16 2-3/32 3-9/16 1.13 III 4201-291 2-1/2x2-1/2x1-1/2 1-3/16 1/2 1-3/16 2-15/16 1-7/8 2-15/16 5-7/8 3-15/32 2-11/32 3-15/32 1.26 4201-292 2-1/2x2-1/2x2 1-13/32 1-5/8 1-13/32 3-3/16 3-1/8 3-3/16 6-3/8 3-1/2 2-7/8 3-1/2 1.37 4201-335 3x3x1 7/8 1-15/16 7/8 2-3/4 3-1/16 2-3/4 5-15/32 4-3/16 1-23/32 4-3116 1.26 4201-336' 3x3x1-1/4 1-3/8 1-3/4 1-3/8 3-5/16 3-1/2 3-5/16 6-5/8 4-1/8 2-7/8 4-1/8 1.94 4201-337 3x3x1-1/2 1-5/32 2-1/16 1-5/32 3-1/32 3-7/16 3-1/32 6-3/32 4-3/16 2-3/8 4-3/16 1.46 4201-338 3x3x2 1-7/16 1-13/16 1-7/16 3-5/16 3-5/16 3-5/16 6-19/32 4-3/16 2-7/8 4-3/16 1.69 4201-339 3x3x2-1/2 1-3/4 1-31/32 1-3/4 3-5/8 3-23/32 3-518 7-1/4 4-3/16 3-17/32 4-3/16 2.11 Branch Outlet Sized with Bushing TorqueSafeTM SPRINKLER HEAD TEE Gasket Sealed Brass M' Thread Insert Style G1 t Socket x Socket x Gasket Fipt H1 - With Elastomer Seal-Use NO Thread Sealant M 1111 1111 M2 momiMI iiiiiiiiiiii INE G — G2 H-0-- H2-0- L 2—►L Part Number Size G G1 G2 H H1 H2 L M M1 M2 Approx.Wt.(Lbs.) 4202-101 G 3/4x3/4x1/2 7/16 1-3/16 7/16 1-7/16 1-7/16 1-17/32 2-29/32 1-3/8 1-3/8 1-3/8 .22 4202-124 G 1x3/4x1/2 7/16 1-11/32 9/16 1-9/16 1-11/16 1-9/16 3-1/8 1-11/16 1-3/8 1-3/8 .26 4202-130 G 1xlx1/2 7/16 1-11/32 7/16 1-9/16 1-11/16 1-9/16 3-1/8 1-23/32 1-3/8 1-23/32 .28 4202-131 G 1x1x3/4 17/32 15/16 17/32 1-11/16 1-5/8 1-11/16 3-11/32 1-23/32 1-9/16 1-23/32 .31 4202-166 G 1-1/4x1-1/4x1/2 7/16 1-5/8 7/16 1-11/16 1-15/16 1-11/16 3-3/8 2-1/16 1-3/8 2-1/16 .34 4202-209 G 1-1/2x1-1/2x1/2 1/2 1-13/16 1/2 1-7/8 2-3/32 1-7/8 3-3/4 2-11/32 1-3/8 2-11/32 .41 1110 4202-247 G 2x2x1/2 1/2 2-1/16 1/2 2 2-11/32 2 4-1/32 2-27/32 1-3/8 2-27/32 .54 Not intended to convey or dispense water for human consumption through drinking or cooking 3 SPEARS`'MANUFACTURING COMPANY 0 ( FlameGuard® CPVC FIRE SPRINKLER PIPING PRODUCTS SPEARS SPRINKLER HEAD TEE M1 Brass Thread Insert Style iV Ilii Gi t Socket x Socket x Fipt f_ _ G Hi M ,. MT I G H 2 G2 i L —.- Part ►Part Number Size G G1 G2 H H1 H2 L M M1 M2 Approx.Wt.(Lbs.) 4202-010 1x1x1 21/31 1-1/8 21/31 1-25/32 1-29/32 1-25/32 3-19/32 1-23/32 1-23/32 1-23/32 .37 Not intended to convey or dispense water for human consumption through drinking or cooking SofTorqueTM SR REDUCING TEE Gasket Sealed Special Reinforced Plastic Thread Style Socket x Socket x SR Fipt Ml With Elastomer Seal-Use NO Thread Sealant , AI di 16 G1 H1 11111111M2/ i 4___ • G Mini G2 H H2--, Part Number Size G G1 G2 H H1 H2 L M M1 M2 Approx.Wt.(Lbs.) 4202-101GSR 3/4x3/4x1/2 7/16 1-1/2 7/16 1-3/8 1-7/8 1-3/8 2-3/4 1-5/16 1-3/8 1-5/16 .16 4202-130GSR 1x1x1/2 7/16 1-5/8 7/16 1-1/2 2 1-1/2 3 1-5/8 1-3/8 1-5/8 .20 SPRINKLER REDUCING HEAD TEE —M1.. Brass Thread Insert Style ` =_' T Socket x Socket x Fipt �_.._�"`3 H1 L•al ! G1 G mg G2 t—H H2— Part Number Size G G1 G2 H H1 H2 L M M1 M2 Approx.Wt.(Lbs.) 4202-101 3/4x3/4x112 7/16 1-1/16 7/16 1-15/32 1-5/8 1-15/32 2-29/32 1-13/32 1-3/16 1-13/32 .20 4202-124 1x3/4x1/2 7/16 1-11/32 9/16 1-9/16 1-11/16 1-9/16 3-1/8 1-11/16 1-3/8 1-3/8 .26 4202-130 1x1x1/2 7/16 1-7/32 7/16 1-9/16 1-25/32 1-9/16 3-1/8 1-3/4 1-3/16 1-3/4 .26 4202-156 1-1/4x1x1/2 7/16 1-7/16 9/16 1-11/16 2-1/32 1-11/16 3-3/8 2-3/32 1-3/16 1-23/32 .30 4202-166 1-1/4x1-1/4x1/2 7/16 1-15/32 7/16 1-11/16 2-1/32 1-11/16 3-3/8 2-3/32 1-3/16 2-3/32 .31 4202-199 1-1/2x1-1/4x1/2 1/2 1-5/8 9/16 1-7/8 2-3/16 1-13/16 3-11/16 2-11/32 1-3/16 2-1/16 .37 4202-209 1-1/2x1-1/2x1/2 1/2 1-5/8 1/2 1-7/8 2-3/16 1-7/8 3-3/4 2-11/32 1-3/16 2-11/32 .38 4202-237 2x1-1/2x1/2 1/2 1-27/32 17/32 2 2-7/16 1-29/32 3-15/16 2-7/8 1-3/16 2-11/32 .47 4202-247 2x2x1/2 1/2 1-7/8 1/2 2 2-7/16 2 4-1/32 2-27/32 1-3/16 2-27/32 .50 III Not intended to convey or dispense water for human consumption through drinking or cooking MADE IN THE U.S.A. 4 SPEARS FlameGuard® CPVC FIRE SPRINKLER PIPING PRODUCTS • SPRINKLER HEAD TEE Special Reinforced r--mil Plastic Thread Style ;—� G1 t Socket x Socket x SR Fipt �.' 16-� M 111 11 M2 G2 1.G H H2-"- L ► Part Number Size G G1 G2 H H1 H2 L M M1 M2 Approx.Wt. (Lbs.) 4202-010SR 1x1x1 21/32 3/4 21/32 1-25/32 1-5/8 1-25/32 3-19/32 1-23/32 1-11/16 1-23/32 26 SPRINKLER REDUCING HEAD TEE H-M1H Special Reinforced i 1EL t Plastic Thread Style ... 7H1 Socket x Socket x SR Fipt M M2 t t I__ I G1 G G2 -4--H 4-H2- A L Part Number Size G G1 G2 H H1 H2 L M M1 M2 Approx.Wt. (Lbs.) • 4202-101SR 3/4x3/4x1/2 19/32 25/32 19/32 1-19/32 1-7/16 1-19/32 3-7/32 1-13/32 1-3/16 1-13/32 .15 4202-124SR 1x3/4x1/2 7/16 29/32 9/16 1-19/32 1-5/8 1-9116 3-5/32 1-23/32 1-3/16 1-17/32 .19 4202-130SR 1x1x1/2 7/16 29/32 7/16 1-9/16 1-5/8 1-9/16 3-1/8 1-23132 1-3/16 1-23/32 .20 4202-156SR 1-1/4x1x1/2 15/32 1-5/32 19/32 1-23/32 1-7/8 1-23/32 3-13/32 2-3/32 1-3/16 1-23/32 .26 4202-166SR 1-1/4x1-1/4x1/2 7/16 1-1/8 7/16 1-11/16 1-27/32 1-11/16 3-3/8 2-3/32 1-3/16 2-3/32 .26 4202-168SR 1-1/4x1-1/4x1 27/32 1-1/32 27/32 2-3/32 1-29/32 2-3/32 4-7/32 2-3/32 1-11/16 2-3/32 .34 4202-199SR 1-112x1-1/4x1/2 9/16 1-9/32 17/32 1-15/16 2 1-25/32 3-23/32 2-11/32 1-3/16 2-3/32 .33 4202-209SR 1-1/2x1-1/2x1/2 1/2 1-1/4 1/2 1-7/8 1-31/32 1-7/8 3-3/4 2-11/32 1-3/16 2-11/32 .35 4202-211SR 1-1/2x1-1/2x1 27/32 1-7/32 27/32 2-7/32 2-1/8 2-7/32 4-15/32 2-11/32 1-23/32 2-11/32 .44 4202-237SR 2x1-1/2x1/2 23/32 1-9/16 3/8 2-7/32 2-9/32 1-3/4 3-31/32 2-7/8 1-3/16 2-11/32 .45 4202-247SR 2x2x1/2 1/2 31/32 1/2 2 1-11/16 19/32 4 2-7/8 1-3116 2-7/8 .48 4202-287SR 2-1/2x2-1/2x1/2 17/32 1-3/4 17/32 2-9/32____ 2-1/2_ 2-9/32 _ 4-19/32 3-1/2 1-7/32 3-1/2 .78 SOFTORQUETM r-M,-..1 SR SPRINKLER HEAD TEE ! 1 Gasket Sealed -Special "' p .6. . . t Reinforced Plastic Thread Style 1 I Mz + l Socket x SR Fipt x Socket I j j r. Stainless Steel Collar With Elastomer Seal-Use G k �z NO Thread Sealant H2 Part Number Size G G1 G2 H H1 H2 L M M1 M2 Approx.Wt.(Lbs.) • 4203-122GSR 1x1/2x1 13/16 13/16 1-1/2 1-27/32 1-27/32 1-31/32 3-13/16 1-5/8 1-5/8 1-3/8 .22 5 SPEARS'MANUFACTURING COMPANY FlameGuard® CPVC FIRE SPRINKLER PIPING PRODUCTS ) ,, 0 ( TorqueSafeTM M1_._ SPRINKLER HEAD TEE Gasket Sealed AIM G1 G1 H1 Brass Thread Insert Style 1 iii wilifi M2 Socket x Gasket Fipt x Socket +I -1016 I11 With Elastomer Seal-Use NO Thread Sealant G G2 4 H -4—H2---1-- L Part Number Size G G1 G2 H H1 H2 L M M1 M2 Approx.Wt.(Lbs.) 4203-122 G 1x1/2x1 19/32 13/16 1-13/32 1-19/32 1-27/32 1-3/4 3-11/32 1-5/8 1-5/8 1-3/8 .25 Not intended to convey or dispense water for human consumption through drinking or cooking SPRINKLER HEAD TEE .—M1--►1 Brass Thread Insert Style t Socket x Fipt x Socket Apit_ G1 4.1 • M hi��l� MZ 0 MILL G G2 --.1—H H2—..- ,i L -.." Part Number Size G G1 G2 H H1 H2 L M M1 M2 Approx.Wt.(Lbs.) 4203-122 1x1/2x1 23/32 3/4 1-1/4 1-5/8 1-5/8 1-15/16 3-1/2 1-23/32 1-23/32 1-3/16 .25 Not intended to convey or dispense water for human consumption through drinking or cooking SPRINKLER HEAD TEE Special Reinforced —M1-1 Plastic Thread Style _PEI G1 t Socket x SR Fipt x Socket H1 M111.11171-1 1II1i'I j G 4 ► G2 .—H –4 H2--4.. -4-- L ► Part Number Size G G1 G2 H H1 H2 L M M1 M2 Approx.Wt.(Lbs.) 4203-122SR 1x1/2x1 27/32 23/32 1-3/32 1-23/32 1-5/8 1-25/32 3-13/32 1-3/4 1-3/4 1-3/16 .21 • MADE IN THE U.S.A. 6 SPEARS FlameGuard® CPVC FIRE SPRINKLER PIPING PRODUCTS • STREET TEE Spigot x Socket x Socket PIPED I M2 t1 i r I c. ! . G1 G 4 ► 4 ► G2 H --10-1-0— H2—,-- -.--- L Part Number Size G G1 G2 H H1 H2 L M1 M2 Approx.Wt.(Lbs.) 4244-007 3/4 13/16 27/32 27/32 1-13/16 1-7/8 1-7/8 3-5/8 1-13/32 1-13/32 .16 4244-010 1 1-5/32 1-1/32 1-1/32 2-1/8 1-29/32 1-29/32 4-3/16 1-3/4 1-3/4 .27 4244-012 1-1/4 1-1/4 1 1 2-7/16 2-9/32 2-9/32 4-27/32 2-3/32 2-3/32 .42 4244-015 1-1/2 1-13/16 1-1/8 1-1/8 2-7/8 2-9/16 2-9/16 5-11/32 2-11/32 2-11/32 .56 4244-020 2 1-23/32 1-7/16 1-13/32 3-1/4 2-15/16 2-15/16 6-5/32 2-7/8 2-7/8 .84 • 90° ELBOW Socket x Socket G H � --- i Inir 1-0--M--P-I Part Number Size G H M Approx.Wt.(Lbs.) 4206-007 3/4 9/16 1-1/2 1-5/16 .07 4206-010 1 3/4 1-5/8 1-5/8 .11 4206-012 1-1/4 15116 2-3/16 2 .22 4206-015 1-1/2 1-5/32 2-17/32 2-3/8 .41 4206-020 2 1-13/32 2-29/32 2-7/8 .62 4206-025 2-1/2 1-15/32 3-3/8 3-1/2 1.15 4206-030 3 1-5/32 3-3/32 4-3/16 1.83 • 7 SPEARS MANUFACTURING COMPANY FlameGuard® CPVC FIRE SPRINKLER PIPING PRODUCTS SPEARS • ( SIDE OUTLET ELBOW Socket x Socket x Socket Ii M ..........i G Nisi H Part Number Size G H M Approx.Wt.(Lbs.) 4213-007 3/4 27/32 1-19/32 1-5/16 .09 4213-010 1 13/16 1-7/8 1-5/8 .18 REDUCING 90° ELBOW Socket x Socket Hl G1 nu • /I Ml i iur h--M--►t Part Number Size G G1 H H1 M M1 Approx.Wt. (Lbs.) 4206-131 1x314 21/32 13/16 1-25/32 1-13/16 1-19/32 1-5/16 .11 TorqueSafe."'90° SPRINKLER HEAD ELBOW Gasket Sealed Brass Thread Insert Style Socket x Gasket Fipt With Elastomer Seal-Use NO Thread Sealant H1—.- G1 r_ GO� i Illi~ ml Iik i 4. 1F-1-111 w. ..--M Part Number Size G G1 H H1 M M1 Approx.Wt.(Lbs.) 111 4207-101 G 3/4x1/2 9/16 1-7/32 1-13/32 1-17/32 1-13/32 1-3/8 .19 4207-130G 1x112 7/16 1-3(16 1-9/16 1-11/16 1-23/32 1-3/8 .23 4207-166 G 1-1/4x1/2 15/32 1-19/32 1-15/16 1-11/16 2-3/32 1-3/8 .25 Not intended to convey or dispense water for human consumption through drinking or cooking MADE IN THE U.S.A. 8 SPEARS FlameGuard® CPVC FIRE SPRINKLER PIPING PRODUCTS • SPRINKLER HEAD 90° ELBOW Brass Thread Insert Style H1 Socket x Fipt G1 mu G r�l►1l1�illi Ml I •IIt ) 1 li ,.._ m —.I Part Number Size G G1 H H1 M M1 Approx.Wt.(Lbs.) 4207-101 314x1/2 1/2 1-3/32 1-1/2 1-5/8 1-13/32 1-3/16 .17 4207-130 1x1/2 7/16 1-7/32 1-19/32 1-25/32 1-23/32 1-3/16 .21 4207-131 1x3/4 17/32 1-11/32 1-21/32 1-31/32 1-23/32 1-3/8 25 4207-166 1-1/4x1/2 15/32 1-17/32 1-11/16 1-15/16 2-3/32 1-17/32 33 Not Intended to convey or dispense water for human consumption through drinking or cooking SofTorqueTM SR 90° ELBOW SPRINKLER HEAD ADAPTER Gasket Sealed Special Reinforced Plastic Thread Style Socket x SR Fipt H1 With Elastomer Seal-Use NO Thread Sealant G1 LI1IJf 1 Ill1 M--.-I Part Number Size G G1 H H1 M M1 Approx.Wt.(Lbs.) 4207-101GSR 3/4x1/2 7/16 1-17/32 1-3/8 1-27/32 1-11/32 1-3/8 17 4207-130GSR 1x1/2 7/16 1-11/16 1-1/2 2 1-21/32 1-3/8 .19 4207-166GSR 1-1/4x1/2 7/16 1-718 1-11/16 2-7/32 2 1-3/8 .22 SPRINKLER HEAD 90° ELBOW Special Reinforced Plastic Thread Style --H1—+1 Socket x SR Fipt G1 G ri,,,:, 11 : ,„,„„, i 1 imr-----T I-0-M-i1 Part Number Size G G1 H H1 M M1 Approx.Wt.(Lbs.) 4207-101SR 3/4x1/2 11/32 13/16 1-15/32 1-1/2 1-13/32 1-3/16 .14 4207-130SR 1x112 7/16 7/8 1-9/16 1-5/8 1-23/32 1-3/8 .20 • 4207-131SR 1x3/4 1/2 7/8 1-5/8 1-9/16 1-23/32 1-3/8 .16 4207-166SR 1-114x1/2 13/32 1-1/32 1-21/32 1-23/32 2-3/32 1-7/32 .19 9 SPEARS" MANUFACTURING COMPANY FlameGuard® CPVC FIRE SPRINKLER PIPING PRODUCTS ) SMRS • ( 90° STREET ELBOW H, • Spigot x Socket G1 NM G 111/11 HiH ilir I- -I PIPEOD. Part Number Size G G1 H H1 M1 Approx.Wt. (Lbs.) 4209-007 3/4 29/32 19/32 1-15/16 1-11/16 1-13/32 .12 4209-010 1 1-9/32 23/32 2-13/32 1-27/32 1-3/4 21 4209-012 1-1/4 1-9/16 27/32 2-13/16 2-3/32 2-3/32 32 4209-015 1-1/2 1-15/32 1-3/16 2-27/32 2-9/16 2-11/32 .42 4209-020 2 1-23/32 1-3/8 3-7/32 2-15/16 2-27/32 .65 22-1/2° ELBOW Socket x Socket HL]{ • Part Number Size H J M Approx.Wt.(Lbs.) 4216-007 3/4 1-3/16 7/32 1-13/32 09 4216-010 1 1-3/8 9/32 1-25/32 .14 4216-012 1-1/4 1-1/2 5/16 2-3/32 .20 4216-015 1-1/2 1-7/16 13/32 1-3/8 .19 4216-020 2 1-7/8 3/8 2-27/32 .43 4216-030 3 2-3/8 1/2 4-5/32 1.00 22-1/2° STREET ELBOW Spigot x Socket Hi - /-'` M1 Jt J / WI( I' I_PIPF O D. Part Number Size H Hi J Ji M1 Approx.Wt.(Lbs.) 4242-007 3/4 1-1/4 1-1/2 1/4 1/2 1-3/8 08. III 4242-010 1 1-7/16 1-11/32 5/16 7/32 1-23132 14 4242 012 1-1/4 1-9/16 1-25/32 17/32 11/16 2-1/16 21. 4242-015 1-1/2 1-13/32 123!32 1/2 11/32 2-11/32 .28 4242-020 2 1-29/32 2-1/8 7/32 5/8 2-7/8 .42 4242-025 2-1/2 2-1/8 2-1/4 13/32 1/2 3-1/2 68 4242-030 3 2-13/32 2-13/32 9/16 17/32 4-5/32 99 MADE IN THE U.S.A. 10 SPEARS , FlameGuard® CPVC FIRE SPRINKLER PIPING PRODUCTS • 45° ELBOW Socket x Socket J t e I- 1 -M-I Part Number Size H J M Approx.Wt.(Lbs.) 4217-007 3/4 1-5/16 5/16 1-5/16 .07 4217-010 1 1-13/32 3/8 1-5/8 .11 4217-012 1-1/4 1-5/8 3/8 2-5/32 .21 4217-015 1-1/2 1-27/32 15/32 2-11/32 .32 4217-020 2 2-1/8 21/32 2-7/8 .48 4217-025 2-1/2 2-17/32 3/4 3-1/2 .88 4217-030 3 2-29/32 29/32 4-5/32 1.17 S CROSS Socket x Socket x Socket x Socket J f I -- Lt___ _I I M - L1 ___rl� F___ Hi In G H Part Number Size G G1 H H1 L L1 M Approx.Wt. (Lbs.) 4220-007 3/4 5/8 5/8 1-21/32 1-21/32 3-5/16 3-5/16 1-13/32 .22 4220-010 1 3/4 3/4 1-5/8 1-5/8 3-1/4 3-1/4 1-23/32 .20 4220-012 1-1/4 1-1/8 1-1/8 2-3/8 2-3/8 4-3/4 4-3/4 2-3/32 .63 4220-015 1-1/2 1-7/32 1-7/32 2-5/8 2-5/8 5-7/32 5-7/32 2-3/8 .80 4220-020 2 1-1/2 1-1/2 3 3 6 6 3 1.43 4220-025 2-1/2 1-11/16 1-11/16 3-7/16 3-7/16 6-7/8 6-7/8 3-17/32 2.16 4220-030 3 2-3/32 2-3/32 3-31/32 3-31/32 7-15/16 7-15/16 4-7/16 3.37 • 11 SPEARS'MANUFACTURING COMPANY O ( FlameGuard® CPVC FIRE SPRINKLER PIPING PRODUCTS SPEARS 45° STREET ELBOW Spigot x Socket H1JN A\ J1 Ml IH 7-111111( 1= "-PIPE O.D. Part Number Size H Hi J Ji M1 Approx.Wt.(Lbs.) 4227-010 1 1-1/2 1-5/16 1/2 114 1-5/8 .10 4227-012 1-1/4 1-25/32 1-9/16 9/16 11/32 1-31/32 15 4227-015 1-1/2 2-1/32 2-1/8 19/32 25/32 2-11/32 .29 4227-020 2 2-5/16 1-15/16 25/32 13/32 2-7/8 44 REDUCING CROSS 1---►rMl Socket x Socket x Socket x Socket t _ I i t 3 + 1 I M — —I- -T L1 i--1 ,n G1 I • G I H • I -� Part Number Size G G1 H Hi L Li M Mi Approx.Wt.(Lbs.) 4220-131 1x3/4 23/32 5/8 1-5/8 1-5/8 3-1/4 3-1/4 1-7/8 1-1/2 .31 4220-167 1-1/4x3/4 1-1/16 23/32 2-1/16 1-31/32 4-3/32 3-31/32 2-1/16 1-13/32 .35 4220-210 1-1/2x3/4 11/16 1-5/32 2-3/32 2-3/16 4-3/16 4-11/32 2-3/8 1-13/32 42 4220-248 2x3/4 11/16 1-7/16 2-7/32 2-7/16 4-13/32 4-7/8 2-29/32 1-13/32 .56 4220-289 2-1/2x1 29/32 1-3/4 2-11/16 2-7/8 5-11/32 5-3/4 3-1/2 1-3/4 98 COUPLING Socket x Socket 1 I i 1 N-+i 1 Part Number Size L M N Approx.Wt. (Lbs.) 4229-007 3/4 2-1/8 1-5/16 3/16 .05 4229-010 1 2-306 1-5/8 3/32 .08 4229-012 1-1/4 2-19/32 2 3/32 .13 • 4229-015 1-1/2 2-7/8 2-11/32 3/32 .22 4229-020 2 3-1/8 2-7/8 1/8 .33 4229-025 2-1/2 3-11/16 3-15/32 306 .48 4229-030 3 4 4-3/16 1/4 .89 MADE IN THE U.S.A. 12 SPEARS FlameGuard® CPVC FIRE SPRINKLER PIPING PRODUCTS • REDUCER COUPLING Socket x Socket T--ummi......... M - _ 1111 Ml Lmoiw- 1 N Part Number Size L M M1 N Approx.Wt. (Lbs.) 4229-131 1x3/4 2-3/8 1-23/32 1-13/32 7/32 .10 4229-167 1-1/4x3/4 2-19/32 2-3/32 1-5/8 11/32 .17 4229-168 1-1/4x1 2-11/16 2-3/32 1-23/32 5/16 .18 4229-210 1-1/2x3/4 2-13/16 2-11/32 1-13/32 15/32 .19 4229-211 1-1/2x1 2-7/8 2-11/32 1-15/16 3/8 24 4229-212 1-1/2x1-1/4 2-13/16 2-13/32 2-1/8 5/32 .23 4229-248 2x3/4 3-306 2-7/8 1-7/16 23/32 .32 4229-249 2x1 3-1/8 2-7/8 1-23/32 1/2 .31 4229-250 2x1-1/4 3-306 2-7/8 2-1/8 17/32 .33 Ill . 4229-251 2x1-1/2 3-306 2-27/32 2-11/32 9/32 .31 4229-291 2-1/2x1-1/2 3-23/32 3-15/32 2-11/32 21/32 .51 4229-292 2-1/2x2 3-21/32 3-1/2 2-7/8 13/32 .52 4229-337 3x1-1/2 3-1/2 4-3/16 2-3/8 7/32 .71 4229-339 3x2-1/2 3-27/32 4-3/16 3-1/2 3/16 80 GripLocTM COUPLING - LEAD FREE w/EPDM 0-Ring Seals L 175 psi Maximum - Internal Pressure @ 150°F WM: IIMMI M 1-+—L1 WARNING: DO NOT INSERT FINGERS. Part Number Size L M1 N Approx.Wt. (Lbs.) GL4229-007 3/4 4 1-15/16 1-29/32 .25 GL4229-010 1 4-5/32 2 2-1/4 .34 • 13 SPEARS'MANUFACTURING COMPANY 0 ( FlameGuard® CPVC FIRE SPRINKLER PIPING PRODUCTS ) En GROOVED COUPLING ADAPTER Groove x Socket + Y,..a.-Eli——7 PAPE M1 O.D. PI 7 . NaL Part Number Size L M1 N Approx.Wt.(Lbs.) 4233-012 1-1/4 3-5/8 2-3/32 2-11/32 72 4233-015 1-1/2 3-3/4 2-11/32 2-11/32 .83 4233-020 2 3-27/32 2-27/32 2-11/32 1.27 4233-025 2-1/2 4-3/16 3-15/32 2-7/16 2.02 4233-030 3 4-5/16 4-1/8 2-7/16 2.76 Not intended to convey or dispense water for human consumption through drinking or cooking FEMALE ADAPTER Brass Thread Insert Style Socket x Fipt M Ilia N,„ • 1111111l N -0 L--0--t— Part Number Size L M M1 N Approx.Wt. (Lbs.) 4235-007 3/4 2 1-13/32 1-3/8 5/16 .23 4235-010 1 2-3/16 1-3/4 1-11116 11/32 .25 4235-012 1-1/4 2-3/8 2-3/32 2-1/16 3/8 .36 4235-015 1-1/2 2-17/32 2-3/8 2-7/16 3/8 .47 4235-020 2 2-25/32 2-27/32 3-3116 7/16 1.05 Not intended to convey or dispense water for human consumption through drinking or cooking FEMALE ADAPTER Special Reinforced Plastic Thread Style 1 — Socket x SR Fipt M IIS::...,. M1 1 IIIINIIIIi N _,_._ 1 >L • Part Number Size L M M1 1 N Approx.Wt.(Lbs.) 4235-007SR 3/4 1-7/8 1-13/32 1-3/8 3/32 .08 4235-010SR 1 2-5/32 1-23/32 1-7/8 3/32 .22 4235-012SR 1-1/4 2-5/16 2-1/8 2-1/16 3116 20 MADE IN THE U.S.A. 14 SPEARS . ( FIameGuard® CPVC FIRE SPRINKLER PIPING PRODUCTS • FEMALE SPRINKLER HEAD ADAPTER Special Reinforced Plastic Thread Style Socket x SR Fipt M - Ild Mil 1 N-4-0- _..,_ L_ Part Number _ Size L M M1 N Approx.Wt. (Lbs.) 4235 101S 3/4x1/2 1-29/32 1-13/32 1-3/16 1/8 .08 4235 130S 1x1/2 1-31/32 1-23/32 1-3/8 3/32 .16 4235-131SR 1x3/4 2-3/32 1-3/4 1-3/8 1/4 .13 III FEMALE SPRINKLER HEAD ADAPTER Special Reinforced Plastic Thread Style with Socket Wrench Flats Socket x SR Fipt NO M - Ml M= Flat-to-Flat Dimension 11001', N Pal L Part Number Size L M M1 N Approx.Wt. (Lbs.) W4235-101SR 3/4x1/2 2-9/32 1-13/32 1-3/16 17/32 .09 W4235-130SR 1x1/2 2-9/32 1-3/4 1-3/16 13/32 .12 • SPEARS`' MANUFACTURING COMPANY • ( FlameGuard® CPVC FIRE SPRINKLER PIPING PRODUCTS ) rillimspEARs Immil SPIGOT FEMALE ADAPTER Brass Thread Insert Style F 1 ..— Spigot x Fipt PIPE ____1Iii 0 ID 11 II 1 1 1111 M1 N44-1.- 4 L Part Number Size L M1 N Approx.Wt.(Lbs.) 4278-007 3/4 2-5/32 1-3/8 17/32 .15 4278-010 1 2-9/32 1-11/16 7/16 .22 Not intended to convey or dispense water for human consumption through drinking or cooking SPIGOT FEMALE ADAPTER Special Reinforced Plastic Thread Style Spigot x SR Fipt ? 1/1 IIIINPIPEMl 1 III N—I.--. Part Number Size L M1 N Approx.Wt.(Lbs.) 4278 007S 3/4 1-15/16 1-3/8 11/32 .08 4278-010SR 1 2-1/4 1-23/32 13/32 .13 TorqueSafeTM FEMALE SPRINKLER HEAD ADAPTER Gasket Sealed Brass Thread Insert Style Socket x Gasket Fipt With Elastomer Seal-Use NO Thread Sealant - II— I M _--- iSIiI Ml ''et _ 0.1,2l N--I----• L Part Number Size L M Ml N Approx.Wt.(Lbs.) 4235-101 G 3/4x1/2 1-7/8 1-13/32 1-3/8 9/16 15 4235-130GS 1x1/2 2-1/32 1-1106 1-3/8 17/32 .17 4235-131 G 1x3/4 2 1-11/16 1-9/16 9/16 .18 • Not intended to convey or dispense water for human consumption through drinking or cooking MADE IN THE U.S.A. 16 SPEARS , FlameGuard® CPVC FIRE SPRINKLER PIPING PRODUCTS • FEMALE SPRINKLER HEAD ADAPTER Brass Thread Insert Style Socket x Fipt M =Illiiiiiii 1\111 IIb110llt N L Part Number Size L M M1 N Approx.Wt.(Lbs.) 4235-101 314x112 1-7/8 1-13/32 1-17/32 15/32 .19 4235-130 1x1/2 2-11/32 1-11/16 1-3116 5/8 .16 4235-131 1x3/4 2-5/16 1-11/16 1-3/8 17/32 .18 Not intended to convey or dispense water for human consumption through drinking or cooking SoflorqueTM SR FEMALE SPRINKLER HEAD ADAPTER Gasket Sealed Special Reinforced Plastic Thread Style Socket x SR Fipt With Elastomer Seal-Use NO Thread Sealant L 1 0 M ------ 1 'll N i 1 1 . N Part Number Size L M M1 N Approx.Wt.(Lbs.) 4235-101GSR 314x1/2 2-5/16 1-5/16 1-3/8 31/32 .11 4235-1300SR 1x1/2 2-13/32 1-19/32 1-3/8 31/32 .13 4235-131GSR 1x3/4 2-13/32 1-5/8 1-23/32 1 .16 QuickTorqueTM SR FEMALE SPRINKLER HEAD ADAPTER Gasket Sealed Special Reinforced Plastic Thread Style Socket x SR Metal Fipt With Elastomer Seal Use NO Thread Sealant r i . !_ii,ilnforced Pl 1 ilial / k—N--.1 Part Number Size L M M1 N Approx.Wt.(Lbs.) 4235-101GMR 3/4x1/2 1-15/16 1-5/16 1-9/16 13/16 .17 III 4235-130GMR 1x1/2 2-3/16 1-19/32 1-9/16 15/16 .19 17 SPEARS' MANUFACTURING COMPANY 0 ( FlameGuard® CPVC FIRE SPRINKLER PIPING PRODUCTS ) SPEARS FEMALE SPRINKLER HEAD ADAPTER I IIIIIIIIIIu•••••4• Brass Thread Insert Style M -—- ill I III M1 MVO Oil with Long Body Socket x Fipt N 1111 f L Part Number Size L M M1 N Approx.Wt.(Lbs.) L4235-130 1x1/2 2-3/16 1-23/32 1-7/32 1/2 19 Not intended to convey or dispense water for human consumption through drinking or cooking FEMALE SPRINKLER HEAD ADAPTER Brass Thread Insert Style -I-- _Y-�- . with Positioning Ring M —----- I M1 Socket x Fipt 1 L. N .►- Part Number Size L M M1 N Approx.Wt.(Lbs.) 0R4235-101 3/4x1/2 2-1/32 1-7/16 1-3/16 15/32 .15 Not intended to convey or dispense water for human consumption through drinking or cooking FEMALE SPRINKLER HEAD ADAPTER Special Reinforced Plastic Thread Style with Positioning Ring M Socket x x SR Fipt IIIIIIIII M1 1 1 N h 4 L Part Number Size L M M1 N Approx.Wt.(Lbs.) R4235-101SR 3/4x1/2 1-15/16 1-7/16 1-7/32 7/32 .09 TorqueSafeTM FEMALE SPIGOT SPRINKLER HEAD ADAPTER Gasket Sealed Brass Thread Insert Style Spigot x Gasket Fipt With Elastomer Seal-Use NO Thread Sealant Mk I f" PIPE — — — . (1!1 I M1 O.D. ��)• hm N L III Part Number Size L M N Approx.Wt.(Lbs.) I! 4238-101 G 3/4x1/2 1-15/16 1-3/8 21/32 .14 4238-130 G 1x1/2 2-1/16 1-3/8 19/32 .15 Not intended to convey or dispense water for human consumption through drinking or cooking MADE IN THE U.S.A. 18 SPEARS FlameGuard® CPVC FIRE SPRINKLER PIPING PRODUCTS • SPIGOT FEMALE SPRINKLER HEAD ADAPTER Brass Thread Insert Style Spigot x Fipt -FminimillilrT'. `" t PIPE — � IliIIIIIII M1 mss• I. N L —•- Part Number Size L M1 N Approx.Wt.(Lbs.) 4238-101 3/4x1/2 1-15/16 1-17/32 17/32 18 4238-130 1x1/2 2-1/4 1-3/16 11/32 .19 Not intended to convey or dispense water for human consumption through drinking or cooking TorqueSafeTM BUSHING - GASKET SEALED Brass Thread Insert Style �■ Spigot x Gasket FIPT f i 47 With Elastomer Seal-Use NO Thread Sealant __ �Itl11 PIPE O.ID. =MIi L--4- • Part Number Size L Approx.Wt. (Lbs.) 4238-130BR G 1x1/2 1-7/32 .10 Not intended to convey or dispense water for human consumption through drinking or cooking BUSHING with BRASS THREAD INSERT Spigot x Fipt �. I1In PR O D. 1 Part Number Size L Approx.Wt.(Lbs.) 4238-130BR 1x1/2 1 .13 Not intended to convey or dispense water for human consumption through drinking or cooking SPIGOT FEMALE SPRINKLER HEAD ADAPTER Special Reinforced Plastic Thread Style Spigot x SR Fipt — PIPE _ IIMMOi 7 INIIIM il I NL 1 L ► • Part Number Size L M1 N Approx.Wt.(Lbs.) 4238-101SR 3/4x1/2 1-29/32 1-7/32 1/8 .07 4238-130SR 1x1/2 2-1/32 1-7/32 7/32 .09 19 SPEARS'MANUFACTURING COMPANY 0 ( FlameGuard® CPVC FIRE SPRINKLER PIPING PRODUCTS SPEARS MALE ADAPTERt With CPVC Lined Thread Brass Insert Mipt x Socket ------ M1 N + L r- Part Number Size L M1 N Approx.Wt.(Lbs.) 4236-007 3/4 2-17/32 1-13/32 13/16 .26 4236-010 1 2-15/16 1-23/32 29/32 .43 4236-012 1-1/4 3-1/8 2-3/32 31/32 .66 4236-015 1-1/2 3-9/32 2-11/32 31/32 .80 4236-020 2 3-7/16 2-27/32 31/32 1.00 ADJUSTABLE SPRINKLER HEAD ADAPTER Special Reinforced Plastic Thread Style Socket x SR Fipt 0 -14: I • N Body L Width Part Number Size L N 0 Body Width Approx.Wt. (Lbs.) Min Max Min Max 42001SR 3/4x1/2 6-9/32 8 4-7/16 6-1/4 1-706 2-306 .66 42011SR 1x1/2 6-13/32 8 4-1/2 6-1/8 1-706 2-1/8 .68 ADJUSTABLE SPRINKLER HEAD ADAPTER Special Reinforced Plastic Thread Style Spigot x SR Fipt PIPE —Q I = tlll Q.D. �lllllll I I. N-- Body '— L Width L N Part Number Size Q Body Width Approx.Wt.(Lbs.) Min Max Min Max 42004SR 3/4x1/2 5-1/32 6-5/16 3-306 4-15/32 1-5/16 2-1/8 .36 42014SR 1x1/2 6-7/16 8-1/8 4-706 6-1/4 1-7/16 2-3/16 .67 III MADE IN THE U.S.A. 20 SPEARS FlameGuard® CPVC FIRE SPRINKLER PIPING PRODUCTS ) III REDUCER BUSHING Flush Style I Spigot x Socket PIPE --_ 0.D. 1 � N - Part Number Size L N Approx.Wt.(Lbs.) 4237-131 1x3/4 1-1/4 1/4 .04 4237-167 1-1/4x3/4 1-7/16 7/16 .10 4237-168 1-1/4x1 1-13/32 9/32 .06 4237-210 1-1/2x3/4 1-5/8 5/8 .19 4237-211 1-1/2x1 1-17/32 13/32 .13 4237-212 1-1/2x1-1/4 1-9/16 5/16 .07 4237-248 2x3/4 1-29/32 29/32 .28 4237-249 2x1 1-23/32 9/16 .23 4237-250 2x1-1/4 1-11/16 7/16 .21 4237-251 2x1-1/2 1-110 6 5/16 .15 4237-290 2-1/2x1-1/4 2-5/32 7/8 .41 4237-291 2-1/2x1-1/2 2-5/32 3/4 .39 4237-292 2-1/2x2 2-9/32 3/4 .28 4237-338 3x2 2-7/32 11/16 63 4237-339 3x2-1/2 2-506 1/4 .42 TRANSITION BUSHING �� III IPS Spigot x CTS Socket PIPE 1111 --- 0.D. 1IIIIIMM. .---- N L- Part Number Size L N Approx.Wt.(Lbs.) 4240-101 3/4x1/2 1-1/8 5/8 .03 4240-130 1 xl l2 1-1/4 23/32 .05 CAP Socket M 311 W Part Number Size M W Approx.Wt.(Lbs.) 4247-007 3/4 1-5/16 1-5/16 .04 4247-010 1 1-5/8 1-9/16 .06 4247-012 1-1/4 2-3/32 1-27/32 .13 4247-015 1-1/2 2-11/32 2 .17 4247-020 2 2-27132 2-9/32 .39 • 4247-025 2-1/2 3-17/32 2-5/8 .50 4247-030 3 4-3/8 3 .92 21 SPEARS' MANUFACTURING COMPANY 0 ( FlameGuard® CPVC FIRE SPRINKLER PIPING PRODUCTS TEST PLUG - 0-ring Sealed Mipt-For Pressure Testing Only, Not For use with Z4235 Series Adapters L '1 R j i i 1/2-14NPT-\ • Part Number Size L M Ml Approx.Wt. (Lbs.) FTP-005 1/2 1-27/32 1-15/16 1-7/32 .03 TEST PLUG for TorqueSafeTM Gasket Sealed Head Adapters Mipt-For Pressure Testing Only. Use ONLY with Gasket Sealed Head Adapters • L----= II -,- 1 , ,.;..zr-- M1 M k ,. mss . 1/2-14 NPT Part Number Size L M M1 Approx.Wt.(Lbs.) FTP-005GS 1/2 1-25/32 2-1/32 1-1/4 05 TEST PLUG (PVC White)Not UL Listed; For Pressure Testing Only, Mipt LSI Part Number Size L Approx.Wt. (Lbs.) • 4250-005 1/2 27/32 .02 MADE IN THE U.S.A. 22 SPEAKS FlameGuard® CPVC FIRE SPRINKLER PIPING PRODUCTS • FLANGE - ONE PIECE 4 Bolt Holes,175 psi Socket 14'— M L R I I n NI I.- BOLT CIRCLE DIA.-6.-I -*- MAX O.D. No.of Bolt Min. Max. Approx.Wt. Part Number Size L M N R Bolt Circle Size Bolt O.D. (Lbs.) Holes Dia. Length 4251-007 3/4 1-5/32 1-1/2 1/8 17/32 4 2-3/4 1/2 2 3-29/32 .31 4251-010 1 1-5/16 1-13/16 1/8 11/16 4 3-1/8 1/2 2-1/4 4-9/32 .35 4251-012 1-1/4 1-13/32 2-7/32 5/32 1106 4 3-1/2 1/2 2-1/4 4-5/8 44 4251-015 1-1/2 1-19/32 2-1/2 3/16 23/32 4 3-27/32 1/2 2-1/2 5-106 61 4251-020 2 1-27/32 3 5/16 27/32 4 4-3/4 5/8 3 5-31/32 .95 4251-025 2-1/2 2-7/32 3-1/2 7/16 1-1/32 4 5-1/2 5/8 3-1/4 7 1.50 BLIND FLANGE 4 Bolt Holes,175 psi LL I 1 BOLT CIRCLE DIA. -►I el MAX O.D. Part Number Size R Bolt No.of Bolt Bolt Size Min. Bolt Max.O.D. Approx.Wt.(Lbs.) Circle Dia. Holes Length 4253-007 3/4 17/32 2-3/4 4 1/2 2 3-27/32 .30 4253-010 1 23/32 3-1/8 4 1/2 2-1/4 4-1/4 .35 4253-012 1-1/4 21/32 3-1/2 4 1/2 2-1/4 4-5/8 .40 4253-015 1-1/2 23/32 3-27/32 4 1/2 2-1/2 5-1/16 .52 4253-020 2 27/32 4-3/4 4 5/8 3 5-31132 86 4253-025 2-1/2 1-1/32 5-1/2 4 5/8 3-1/4 6-15/16 1.70 4253-030 3 1-5/16 b------ _ _-4 -5/8 -_ 3-1/4 7-5/8 X72 FLANGE - TWO PIECE Van Stone Style,4 Bolt Holes, 175 psi Socket M L R t1 111 I I I I I I 1/9®1 N-4 k-BOLT CIRCLE DIA.-.--I MAX O.D. Bolt Circle No.of Bolt Min. Bolt Part Number Size L M N R Dia. Holes Bolt Size Length Max.O.D. Approx.Wt.(Lbs.) III 4254-030 3 2-1/8 4-1/4 9/32 1-1/32 6 4 5/8 3-1/4 7-15/32 1.75 23 SPEARS'MANUFACTURING COMPANY • ( FlameGuard® CPVC FIRE SPRINKLER PIPING PRODUCTS . ) SPEARS FLANGE - TWO PIECE Van Stone Style,4 Bolt Holes,175 psi PIPE 00- Spigot t N 1 li i , (1.- R_ i 1-4--B0LT CIRCLE DIA—► MAX 0.0. i Bolt No.of Bolt Min.Bolt Approx.Wt. Part Number Size L N R Circle Dia. Holes Bolt Size Length Max.O.D. (Lbs.) 4256-007 3/4 1-15/16 13/16 17/32 2-3/4 4 1/2 2 3-27/32 .30 4256-010 1 2-7/32 1-1/32 11/16 3-1/8 4 1/2 2-1/4 4-1/4 .41 4256-012 1-1/4 2-3/8 1 11/16 3-1/2 4 1/2 2-1/4 4-5/8 .50 4256-015 1-1/2 2-7/16 1-3/32 23/32 3-7/8 4 1/2 2-1/2 4-31/32 .65 4256-020 2 2-3/4 1-5/32 25/32 4-3/4 4 5/8 3 5-15/16 1.00 4256-025 2-1/2 3-1/16 1-9/32 1-1/32 5-1/2 4 5/8 3-1/4 6-15/16 1.62 4256-030 3 3-3/8 1-13/32 1-1/32 6 4 5/8 3-1/4 7-9/16 1.76 TRANSITION UNION Brass Thread Insert Style • • Socket x Fipt 175 psi • NUT — — —J II OUT I N—� lal L - Part Number Size L M N Nut O.D. Approx.Wt. (Lbs.) 4259-010BR 1 2-13/16 1-7/8 1-1/32 2-7/8 .52 4259-012BR 1-1/4 3 2-3/16 1-1/8 3-9/32 .98 4259-015BR 1-1/2 3-3/4 2-1/2 1-9/16 3-17/32 .93 4259-020BR 2 3-5/8 2-7/8 1-1/4 4-5/16 1.64 Not intended to convey or dispense water for human consumption through drinking or cooking UNION Socket x Socket MIMI rn.._ 175 psi NUT M �� 1 1111 �.. N L Part Number Size L M N Nut O.D. Approx.Wt.(Lbs.) 4257-007 3/4 2-3/8 1-17/32 3/8 2-1/2 38 • 4257-010 1 2-9/16 1-27/32 3/8 2-7/8 41 4257-012 1-1/4 2-27/32 2-7/32 11/32 3-5/16 .52 4257-015 1-1/2 3-1/8 2-1/2 3/8 3-17/32 .63 4257-020 2 3-5/8 3-1/32 906 4-3/16 1.09 MADE IN THE U.S.A. 24 SPEARS FlameGuard® CPVC FIRE SPRINKLER PIPING PRODUCTS II SotTorqueTM SR FEMALE SPIGOT SPRINKLER HEAD ADAPTER Gasket Sealed Special Reinforced Plastic Thread Style Spigot x SR Fipt With Elastomer Seal-Use NO Thread Sealant PI VIII M1 O.D. t_ 111111 L Part Number Size L M1 N Approx.Wt.(Lbs.) 4278-101GSR 3/4x1/2 2-1/4 1-3/8 1 .11 SHORT REPAIR COUPLING Spigot x Socket 175 psi L2 • 4 L1 o 4 ► L3 • rr I -S 01 Part Number Size L1 L2 L3 M S Approx.Wt.(Lbs.) SH118-07C0 3/4 4-13/16 5-17/32 3/4 1-3/4 2-3/16 .31 SH118-1000 1 4-3/4 5-5/8 31/32 2-1/16 2-5/32 .40 GripLocTM REPAIR COUPLING - LEAD FREE w/EPDM 0-Ring Seals L 175 psi Maximum L—> L Pressure @ 150°F .'tib. — ...tompo!? 1111 11111 L2 WARNING: DO NOT INSERT FINGERS. Part Number Size L L1 L2 M S Approx.Wt. (Lbs.) • SG118-1000 1 1-17/32 7-17/32 4-1/4 2-1/4 2-27/32 .73 25 SPEARS`MANUFACTURING COMPANY • ( FlameGuard® CPVC FIRE SPRINKLER PIPING PRODUCTS SPEARS FlameGuard® CPVC Drain & Swing Check Valves for NFPA 13D Applications Only Application: FlameGuard CPVC Orange Swing Check Valves and PVC/CPVC True Union Drain Valves are for use in configuring CPVC Fire Sprinkler System connection to water supply(riser/drain assembly)in NFPA 13D installations only.These valves are not UL Listed and NOT for use in any other locations within the fire sprinkler system. TRUE UNION INDUSTRIAL DRAIN VALVES CPVC Gray Valve with CPVC Orange End Connector Socket x Socket r4 E D nr,tir 11111111111A B Part Number Size A B C D E III 1822-007CFG 3/4 2-1/4 2-3/4 4-3/4 2-7/8 3-3/8 1822-010CFG 1 2-1/2 2-7/8 5-1/8 3-1/8 3-7/16 1822-012CFG 1-1/4 3-1/16 3-1/4 5-3/4 3-5/8 3-7/8 1822-015CFG 1-1/2 3-1/2 3-1/2 6-1/4 4 4-3/16 1822-020CFG 2 4-1/4 4-3/4 7-3/4 4-1/2 5-1/8 Not UL Listed TRUE UNION DRAIN VALVES PVC Valve with CPVC End Connector Socket x Socket - E + 1 : P 1 ,-----___7_ IA 1 C Part Number Size A B C D E • 3622-007FG 3/4 2-1/4 2-3/4 4-3/4 2 3 3622-010FG 1 2-1/2 2-7/8 5-1/8 2-5/16 3-7/16 Not UL Listed MADE IN THE U.S.A. 26 SPEARS ' FlameGuard® CPVC FIRE SPRINKLER PIPING PRODUCTS • COMPACT 2000 DRAIN VALVE I. E Socket x Socket IL t ID T I 1 1 011 J 1 -.—_g C Part Number Size A B C D E 6622-007C0 3/4 1-13/16 1-1/2 3-9/16 2 3 6622-01000 1 2-1/16 1-3/4 4 2-5/16 3-7/16 Not UL Listed CPVC SWING CHECK VALVES Socket x Socket --f- �1� A L`, i D B Part Number Size A B C D Approx.Wt.(Lbs) 51520-1000 1 1-11/16 2-5/16 4-9/16 2-5/8 .33 S1520-12C0 1-1/4 2-1/16 2-15/16 5-1/2 3-3/8 .42 S1520-15C0 1-1/2 2-7/16 3 5-5/8 3-3/8 .89 Not UL Listed 1 CPVC SPECIAL REINFORCED THREAD INLET SWING CHECK VALVES SR Fipt x Socket AIIIIIIIIIIIII �, I -_ _ D IMO- .. Vimmil JAI . B P. Part Number Size A B C D Approx.Wt.(Lbs) 51520-10FSRSCO 1 1-11/16 2-15/16 4-9/16 2-5/8 .33 S1520-12FSRSCO 1-1/4 2-1/16 3-5/8 5-1/2 3-3/8 .42 • S1520-15FSRSCO 1-1/2 2-7/16 3-11/16 5-5/8 3-3/8 .89 Not UL Listed 27 SPEARS' MANUFACTURING COMPANY 0 NI 0 0 0 4110 PRODUCT LIMITED LIFETIME WARRANTY 3 SPEARS Except as otherwise specified for certain products, mandated by law or herein provided, Spears® Manufacturing Company ("Company") warrants Standard Catalog Products ("Products")which have been directly manufactured by them to be free from defects in material and workmanship for as long as the original intended end user of the Products ("End User") retains ownership and possession of the Products and complies with this Warranty ("Warranty Period"). Each other person or entity acquiring or employing the Products, including buyers, contractors and installers("Buyer') and End Users ("Buyer/End User")agrees that this Warranty shall be effective only during the Warranty Period so long as the Products are used solely for the normal purposes for which they are intended and in conformance with industry established standards, engineering, installation, operating, and maintenance specifications, recommendations and instructions including explicit instructions by the Company;the Products are properly installed,operated and used,and have not been modified;and all the other terms of this Warranty are complied with.Any violation thereof shall void this Warranty and relieve Company from all obligations arising from this Warranty and the Products. Upon receipt or discovery of any Products that appear questionable or defective each Buyer/End User shall promptly inspect and return any such Prod- uct to the Company at 15853 Olden Street, Sylmar, California 91342, accompanied by a letter stating the nature of any problems. If the Prod- ucts are determined by Company to be defective in materials or workmanship directly provided by Company, Company, at its sole option, may ei- ther repair or replace the defective Products, or reimburse applicable Buyer/End User for the cost of such Products. The applicable Buyer/End User shall bear all applicable shipping costs. THIS SHALL BE BUYERS/END USERS' SOLE REMEDY. EACH BUYER/END USER AGREES THAT COMPANY WILL NOT BE RESPONSIBLE FOR ANY OTHER OBLIGATIONS RELATING TO THE PRODUCTS, INCLUDING ANY OTH- ER MATERIALS OR LABOR COSTS, LOSS OF USE OR ANY OTHER ITEM OR FOR ANY DELAYS IN COMPLYING WITH THIS WARRANTY BEYOND COMPANY'S REASONABLE CONTROL. COMPANY SHALL NOT BE LIABLE FOR, DOES NOT ASSUME, AND EXPRESSLY DISCLAIMS, ANY LIABILITY, RESPONSIBILITY AND DAMAGES: DUE TO ANY BUYER/END USER'S FAILURE TO COMPLY WITH THIS WARRANTY, INCLUDING IMPROPER INSTALLATION, USE OR OPERATION; USE WITH PRODUCTS FROM OTHER MANUFACTURERS THAT DO NOT MEET ASTM OR OTHER APPLICABLE PRODUCT STANDARDS;IMPROPER CONTROL OF SYSTEM HYDRAULICS,IMPROPER WINTERIZATION PROCEDURES,IMPROPER VOLTAGE SUPPLY,CON- TACT WITH INCOMPATIBLE MATERIALS OR CHEMICALS, EXCAVATION/DIGGING, EXCESSIVE WEIGHT,AND VANDALISM; DUE TO REASONABLE WEAR AND TEAR AND DUE TO ANY ACTS OF NATURE,INCLUDING LIGHTNING,EARTHQUAKES,GROUND MOVEMENT,FROST HEAVE,OR FLOODS. COMPANY EXTENDS ONLY THIS WARRANTY AND EXPLICITLY DISCLAIMS ALL OTHER WARRANTIES,WHETHER IMPLIED OR OTHERWISE EXPRESSED, WHETHER ORAL,STATUTORY OR OTHERWISE,INCLUDING ANY IMPLIED WARRANTIES OR AFFIRMATIONS FOR SUITABILITY,MERCHANTABILITY OR • FITNESS FOR A PARTICULAR PURPOSE.NO AFFIRMATION BY COMPANY OR ANY OF ITS REPRESENTATIVES,BY WORDS,CONDUCT OR OTHERWISE, SHALL CONSTITUTE A WARRANTY.THIS WARRANTY MAY NOT BE TRANSFERRED,EXTENDED,ALTERED OR OTHERWISE MODIFIED IN ANY MANNER, EXCEPT BY WRITTEN AGREEMENT SIGNED BY COMPANY. BY ITS ACCEPTANCE OF THE PRODUCTS, EACH BUYER/END USER EXPRESSLY WAIVES ALL OTHER LIABILITY OR OBLIGATION OF ANY KIND OR CHARACTER OF COMPANY, INCLUDING LIABILITY PREDICATED UPON CONTRACT, TORT, STRICT LIABILITY OR OTHER LEGAL OR EQUITABLE GROUNDS, AND ALL, IF ANY, DAMAGES AND LOSSES AS A RESULT THEREOF, INCLUDING ALL, IF ANY, COMPENSATORY, GENERAL, SPECIAL, CONSEQUENTIAL, INCIDENTAL, OR PUNITIVE DAMAGES. WITH RESPECT TO SUCH WAIVERS, EACH BUYER/END USER EXPLICITLY WAIVES CALIFORNIA CIVIL CODE §1542 WHICH STATES "A GENERAL RELEASE DOES NOT EXTEND TO CLAIMS WHICH THE CREDITOR DOES NOT KNOW OR SUSPECT TO EXIST IN HIS FAVOR AT THE TIME OF EXECUTING THIS RELEASE, WHICH IF KNOWN BY HIM MUST HAVE MATERIALLY ADVERSELY AFFECTED HIS SETTLEMENT WITH DEBTOR"AND ALL OTHER SIMILAR STATU- TORY,COMMON AND CASE LAW RIGHTS,DEFENSES AND LIMITATIONS. Having previously independently inspected the Products, or a sample, as fully as desired, or having the opportunity to and having not done so, upon acceptance of delivery of the Products,and except as otherwise herein explicitly provided,each Buyer/End User by acceptance or use of the Products accepts them in their"AS IS"and"WITH ALL FAULTS"condition without any other warranty,expressed,implied or otherwise,and accepts and assumes the entire risk and cost of all servicing,remediation and consequences thereof. This Warranty shall be governed by California law and any unenforceable provisions severed without affecting the remainingprovisions.As used herein,Including"includes"without limitation." 9 Spears® Quality Policy It is the policy and objective of Spears®Manufacturing Company to produce a superior quality product suitable for its intended use,with regard to functionality,structural integrity and conformance to established industry standards and practices.It is the commitment of this Company to do so in a manner which provides consistency of product quality,optimum availability,and superior customer service,while maintaining efficiency of operations and profitability necessary to perpetuate product improvement and customer satisfaction.Furthermore, it is recognized that the attainment of these objectives is the responsibility of all Company operations and personnel according to their respective functions. The information contained in this publication is based on current information and product design at the time of publication and is subject to change without notification.Our ongoing • commitment to product improvement may result in some variations. No representations,guarantees or warranties of any kind are made as to its accuracy,suitability for particular application or results to be obtained therefrom. For information not contained herein,please contact Spears°Technical Services Department]West Coast:(818)364-1611—East Coast: (678)985-1263]. Reproduction of this publication in whole or in part is prohibited without the authorized consent of Spears®Manufacturing Company,Sylmar,California. c Copyright 2014 Spears"Manufacturing Company. All Rights Reserved.Printed in the United States of America. • • SPEARS®MANUFACTURING COMPANY ( rIj Corporate OfficeE�BS 15853 Olden Street•Sylmar,CA 91342 PO Box 9203•Sylmar,CA 91392 w (818)364-1611 •http://www.spearsmfg.com 477 • ©Copyright 2015 Spearst Manufacturing Company. All Rights Reserved. Printed in the United States of America 11/15. FG-4-1115 Victaulic° FireLockTM Fittings ✓ctaulic • 10.03 1.0 PRODUCT DESCRIPTION Available Sizes • 1 1/4—8'7DN32— DN200 Maximum Working Pressure • Pressure ratings for Victaulic FireLockTM Fittings conform to the ratings of Victaulic FireLock EZTM Style 009N couplings (refer to publication 10.64 for more information). Application • FireLockTM fittings are designed for use exclusively with Victaulic couplings that have been Listed or Approved for Fire Protection Services. Use of other couplings or flange adapters may result in bolt pad interference. • • Connects pipe, provides change in direction and adapts sizes or components Pipe Materials • Carbon steel 2.0 CERTIFICATION/LISTINGS �Qus ® LLPCB vas C E CD EN 10311 Regulation(EU) No.305/2011 3.0 SPECIFICATIONS-MATERIAL Fitting: Ductile iron conforming to ASTM A536, Grade 65-45-12. Fitting Coating: ❑ Orange enamel. ® Red enamel in Europe, Middle East, Africa, and India. ❑ Optional: Hot dipped galvanized. ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION,MAINTENANCE OR SUPPORT. • • System No. Location I I Spec Section j Paragraph Submitted By Date1 Approved 1 Date victauIic.com 10.03 1539 Rev N Updated 09/2017 ©2017 Victaulic Company.All rights reserved. 1 JCtaUlid 4.0 DIMENSIONS N-CtoE1 i t E 1110 ctoE o a__ -K -bih sr_ E 10 3 ' . •=i= tE 1 No.001 No.003 No.002 No.006 No.001 No.003 No.002 No.006 90°Elbow 45°Elbow Straight Tee Cap Actual Approximate Approximate Approximate Approximate Nominal Outside Weight Weight Weight Weight Size Diameter C to E Each C to E Each C to E Each T Each inches inches inches lb inches lb inches lb inches lb DN mm mm kg mm kg mm kg mm kg 1 Ya 1.660 - - - - - - 0.82 0.3 DN32 42.4 _ _ - - 21 0.1 1 Y2 1.900 - - - - - - 0.82 0.4 DN40 48.3 - - - - - - 21 0.2 2 2.375 2.75 1.7 2.00 1.8 2.75 2.4 0.88 0.6 DN50 60.3 70 0.8 51 0.8 70 1.1 22 0.3 2 1/2 2.875 3.00 3.1 2.25 2.2 3.00 3.6 0.88 1.0 73.0 76 1.4 57 1.0 76 1.6 22 0.5 3.000 3.00 3.30 2.25 2.4 3.00 3.8 DN65 76.1 76 1.5 57 . 1.1 76 1.7 3 3.500 3.38 4.0 2.50 3.1 3.38 5.3 0.88 1.2 DN80 88.9 861.8 64 1.4 86 2.4 22 0.5 4.250 4.00 5.7 3.00 `''' 5.1 , 4.00 7.5 108.0 102 2.6 76 I 2.3 102 3.4 4 4.500 4.00 6.7 3.00 ; 5.6 4.00 8.7 1.00 2.4 DN 100 114.3 102 3.0 76 ! 2.5 102 3.9 25 1.1 5 5.563 4.88 12.6 3.25 F.,. 8.3 4.88 15.7 1.00 4.1 141.3 124 5.7 83 3.8 124 7.1 25 1.9 III 5.500 4.88 12.4 3.25 8.2 4.88 15.4 DN125 139.7 124 5.6 82.6 3.7 124 6.9 6.250 5.50 12.6 3.50 9.2 5.50 17.9 - 158.8 140 5.7 89 4.2 140 8.0 6 6.625 5.50 18.3 3.50 11.7 5.50 22.7 1.00 5.9 DN150 168.3 140 8.3 89 5.3 140 10.3 25 2.7 6.500 5.43 17.6 3.50 11.4 5.50 22.0 _ _ 165.1 140 7.9 89 5.2 140 9.9 8 8.625 6.81 25.5 4.25 20.4 6.94 38.7 1.13 12.7 DN200 219.1 173 11.6 108 i 9.3 176 17.6 29 5.8 8.515 6.81 23.1 - 6.94 33.6 - - 216.3 173 10.5 - - 176 15.2 - - III 10.03 1539 Rev N Updated 09/2017 ©2017 Victaulic Company.All rights reserved. victaulic.corn 2 ✓ctaukc° victaulic.com • . 5.0 PERFORMANCE • Flow Data Size Frictional Resistance Equivalent of Straight Pipe' No.002 Actual Elbows Straight Tee Nominal Outside No.001 No.003 Size Diameter 90°Elbow 45°Elbow ( Branch Run inches inches feet feet feet feet DN mm meters meters meters meters 1'/a 1.660 - - - DN32 42.4 - - - - 1'h 1.900 - - - - DN40 48.3 - - - - 2 2.375 3.5 1.8 8.5 3.5 DN50 60.3 1.1 0.5 2.6 1.1 2'/z 2.875 4.3 2.2 10.8 4.3 73.0 1.3 0.7 3.3 1.3 3.000 4.5 2.3 11.0 4.5 DN65 76.1 1.4 0.7 3.4 1.4 3 3.500 5.0 2.6 13.0 5.0 DN80 88.9 1.5 0.8 4.0 1.5 4.250 6.4 3.2 15.3 6.4 108.0 2.00.9 4.7 2.0 4 4.500 6.8 3.4 16.0 6.8 DN100 114.3 2.1 1.0 4.9 2.1 5 5.563 8.5 4.2 21.0 8.5 141.3 2.6 1.3 6.4 2.6 5.500 8.3 4.1 20.6 8.3 DN125 139.7 2.5 1.3 6.3 2.5 6.250 9.4 4.9 25.0 9.6 • 158.8 2.9 1.5 7.6 2,9 6 6.625 10.0 5.0 25.0 10.0 DN 150 168.3 3.0 1.5 7.6 3.0 ....-- 6.500 :' 9.8 4.9 24.5 9.8 165.1 i 3.0 ,, 1.5 7.5 3.0 8 8.625 13.0 5.0 33.0 13.0 DN200 219.1 4.0 1.5 10.1 4.0 , 8.575__ �_. i 13.0 - 33.0 13.0 216.3 4.0 - 10.1 4.0 1 The flow data listed is based upon the pressure drop of Schedule 40 pipe. III . • 10.03 1539 Rev N Updated 09/2017 ©2017 Victaulic Company.All rights reserved. victaulic.com 3 ✓ctaullc victaulic.com • 6.0 NOTIFICATIONS General Notes • NOTE: When assembling FireLock EZTM couplings onto end caps,take additional care to make certain the end cap is fully seated against the gasket end stop. For FireLock EZTM Style 009N/009H couplings, use FireLockTM No. 006 end caps containing the "EZ" marking on the inside face or No. 60 end caps containing the "QV EZ" marking on the inside face. Non-Victaulic end cap products shall not be used with Style 009/009V/009H/009N couplings. 7.0 REFERENCE MATERIALS 10.64:Victaulic®FireLockT"'Rigid Coupling Style 009N 10.02:Victaulic®FireLockTM Rigid Coupling Style 005H with Vic-PlusiM Gasket System 29.01:Victaulic®Terms and Conditions of Sale • • • • • User Responsibility for Product Selection and Suitability Note Each user bears final responsibility for making a determination as to the suitability of This product shall be manufactured by Victaulic or to Victaulic specifications.All products Victaulic products for a particular end-use application,in accordance with industry to be installed in accordance with current Victaulic installation/assembly instructions. standards and project specifications,and the applicable building codes and related Victaulic reserves the right to change product specifications,designs and standard regulations as well as Victaulic performance,maintenance,safety,and warning equipment without notice and without incurring obligations. instructions.Nothing in this or any other document,nor any verbal recommendation, Installation advice,or opinion from any Victaulic employee,shall be deemed to alter,vary,supersede, Reference should always be made to the Victaulic installation handbook or installation or waive any provision of Victaulic Company's standard conditions of sale,installation instructions of the product you are installing.Handbooks are included with each shipment guide,or this disclaimer. of Victaulic products,providing complete installation and assembly data,and are available Intellectual Property Rights in PDF format on our website at www.victaulic.com. No statement contained herein concerning a possible or suggested use of any material, Warranty product,service,or design is intended,or should be constructed,to grant any license Refer to the Warranty section of the current Price List or contact Victaulic for details. under any patent or other intellectual property right of Victaulic or any of its subsidiaries or affiliates covering such use or design,or as a recommendation for the use of such Trademarks material,product,service,or design in the infringement of any patent or other intellectual Victaulic and all other Victaulic marks are the trademarks or registered trademarks of property right.The terms"Patented"or°Patent Pending"refer to design or utility patents Victaulic Company,and/or its affiliated entities,in the U.S.and/or other countries. or patent applications for articles and/or methods of use in the United States and/or other countries. 10.03 1539 Rev N Updated 09/2017 0 2017 Victaulic Company.All rights reserved. victaulic.com 4 ✓ctaulac` Victaulic° FireLockTM Rigid Couplingjctaullid Style 009N 10.64 tr Patented 1.0 PRODUCT DESCRIPTION Available Sizes • 1 — 12"/32-300mm Pipe Material • Carbon steel, Schedule 10, Schedule 40. For use with alternative materials and wall thicknesses please contact Victaulic. Maximum Working Pressure • Up to 365 psi/2517 kPa. Function • Joins carbon steel pipe. • Provides a rigid pipe joint designed to restrict axial or angular movement. 2.0 CERTIFICATION/LISTINGS • e®us ® LPCBI vds C E LISTED C104-1a/36 EN 10311 Regulation(EU) No.305/2011 ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION,MAINTENANCE OR SUPPORT. • • System No. Location Spec Section I I Paragraph1110 Submitted By Date ; I j Approved Date victaulic.com • 10.64 7072 Rev L Updated 08/2017 ©2017 Victaulic Company.All rights reserved. 1 iCtaulid victaulic.com 3.0 SPECIFICATIONS—MATERIAL Housing: Ductile iron conforming to ASTM A 536, Grade 65-45-12. Ductile iron conforming to ASTM A 395, Grade 65-45-15, is available upon special request. • Housing Coating: (specify choice) ❑ Orange enamel (North America, Asia Pacific) ❑ Red enamel (Europe) ❑ Hot dipped galvanized Gasket: (specify choice1) ❑ Grade"E" EPDM (Type A) FireLock EZ products have been Listed by Underwriters Laboratories Inc., Underwriters Laboratories of Canada Limited, and Approved by Factory Mutual Research for wet and dry(oil free air)sprinkler services within the rated working pressure. Services listed are General Service Guidelines only.It should be noted that there are services for which these gaskets are not compatible.Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service guidelines and for a listing of services which are not compatible. Bolts/Nuts: (specify choice2) Standard: Carbon steel oval neck track bolts meeting the physical and chemical requirements of ASTM A449 (imperial)and ISO 898-1 Class 9.8(metric). Carbon steel hex nuts meeting the physical and chemical requirements of ASTM A563 Grade B (imperial-heavy hex nuts)and ASTM A563M Class 9(metric- hex nuts). Track bolts and hex nuts are zinc electroplated per ASTM B633 ZN/FE5,finish Type III (imperial) or Type II (metric). ❑ Optional: Stainless steel oval neck track bolts meeting the requirements of ASTM F593, Group 2 (316 stainless steel),condition CW. Stainless steel heavy hex nuts meeting the requirements of ASTM F594, Group 2 (316 stainless steel), condition CW,with galling-resistant coating.2 2 Optional bolts/nuts are available in imperial size only. • • • 10.64 7072 Rev L Updated 08/2017 ©2017 Victaulic Company.All rights reserved. victaulic.com 2 �ctaulicc V ct quli*i.com • • 4.0 DIMENSIONS • Style 009N Y Z Y _ : IR �\�:, atIf Irl " ' I ICA Fi N� ILII ‘� ILII Style 009N Pre-Assembled (Push On Condition) Style 009N Joint Assembled Bolt/Nut Dimensions Weight Actual Maximum Maximum Allow. Pre-assembled (Push On Condition) Joint Assembled Nominal Outside Working End Pipe End Approx. Size Diameter Pressure3 Load3 Separation Qty. Size X Y X Y Z (Each) ; inches inches psi lb inches inches inches " inches inches inches inches lb mm mm kPa N mm mm mm mm mm mm mm kg 1 11 1.660 365 790 0.102 3/8 x 2 3.13 5.00 2.75 5.00 2.00 1.4 32 42.4 2517 3514 2.54 M10 x 51 79 127 70 127 51 0.6 11/2 1.900 365 1035 0.102 3/8 x 2 3.38 5.13 3.00 5.13 2.00 1.5 ' 40 483 2517 4604 254 M10 x51 86 130 76 130 51 0.7 2 2375 365 1616 0.12 2 3/8 x21/ 4.00 5.63 350 563 2.00 1.9 50 603 2517 7193 3.05 M10 x 63 102 143 89 143 51 0.9 21/2 2.875 365 2370 0.122 3/a x 21/2 4.50 6.13 4.00 6.13 2.00 2.1 65 73.0 2517 10542 3.05 • M10 x 63 114 156 102 156 51 1.0 76.1 mm 3.000 365 2580 0.12 2 3/a x 21/2 4.63 6.00 • 4.13 6.13 2.00 2.1 76.1 2517 11476 3.05 M 10 x 63 118 152 105 156 51 1.0 3 3.500 365 3512 0.12 2 3/a x 21/2 5.13 6.75 4.63 6.75 2.00 2.3 80 88.9 2517 15622 3.05 M10 x 63 130 171 117 171 51 1.0 4 4.500 365 5805 0.17 2 3/8 x 2'1 6.00 7.88 5.63 750 2.13 2.9 j 100 114.3 2517 25822 432 M10 x 63 152 200 143 191 54 13 4 108.0 mm 4.250 365 5175 0.17 2 %x 21/2 5.63 738 538 738 2.13 3.1 ' 0 108.0 2517 23020 432 M10 x 63 152 1.87 137 187 54 1.4 5 • 5563 365 8870 0.17 1/x 3 725 925 , 6.75 9.13 2.25 5.0 125 141.3 2000 39456 4:32 2 M12 x 76 184 235 171 232 57 23 1330 mm 5250 365 7897 0.172 11 x 3 6.63 900 6.38 9.00 2.25 4.8 133.0 2517 35106 432 M12 x 76 168 229 162 229 57 2.2 139.7 mm 5.500 365 8667 0.17 2 1 x 3 6.88 925 6.75 9.13 225 4.9 • 139.7 2517 38529 432 M12 x 76 175 235 171 232 57 2.2 159.0 mm 6.250 365 11192 0.17 2 11 x 3 1/4 7.88 10.00 738 9.88 225 5.6 159.0 2517 49753 4.32 M12 x83 200 254 187 251 57 2.5 165.1 mm 6.500 i 365 12105 0.17 2 1 x 31/4 8.00 10.25 7.75 10.13 225 6.0 165.1 • 2517 53813 4.32 M12 x 83 203 260 197 257 57 2:7 6 6.625 365 12582 0.17 2 1/x 31/4 838 10.38 7.88 10.13 225 60 I 150 1683 2000 44469 4.32 M12 x 83 213 264 200 257 57 I 2.7 216.0 mm' 8500 365 20712 0.17 2 s1 x 4 10.63 1325 10.25 ' 10.13 2.63 11.4 216.0 2517 55968 4.32 M16 x101 270 337 260 257 67 5.2 8 8.625 365 21326 0.17 5/8 x 4 10.88 1338 1025 13.13 2.50 11.4 200 219.1 1620 94863 4.32 2 M16x101 276 340 260 333 64 5.2 10 10.750 300 27229 0.25 2 '/ax 61/ 13.75 1700 1325 17.13 2.75 22.6' 250 2730 2068 121121 6.4 M22x 165 349 432 337 435 70 ' 10.3 12 12.750 300 38303 0.252 '/a x 6/ 16.00 19.00 15.50 19.13 2.75 27.6 300 323.9 2068 170380 6.4 M22x 165 406 483 394 486 70 12.5 i L Working Pressure and End Load are total,from all internal and external loads,based on standard weight(ANSI)steel pipe,standard roll or cut grooved in accordance with Victaulic specifications.See the Listings/Approvals section of this publication for ratings on other pipe. 4 The allowable pipe separation dimension shown is for system layout purposes only.FireLock EZTM couplings are considered rigid connections and will not accommodate expansion or contraction of the piping system. NOTES • When assembling FireLock EZT"couplings onto end caps,take additional care to make certain the end cap is fully seated against the gasket end stop.For FireLock EZT"Style 009N couplings,use FireLock No.006 end caps containing the"EZ"marking on the inside face or No.60 end caps containing the"QV EZ"marking on the inside face.Non-Victaulic end cap products shall not be used with Style 009N couplings.IMPORTANT:Gaskets intended for the Style 009 or Style 009V couplings cannot be used with the Style 009N coupling.There is no interchanging of gaskets or housings between coupling styles. • Use Of Flushseal Gaskets For Dry Pipe Systems FireLock Er'couplings are supplied with FireLock EZTM Grade"E"Type A gaskets.These gaskets include an integral pipe stop,that once installed provides the similar benefits as a FlushSeal gasket for dry pipe systems.It should be noted that standard Victaulic Flush-Seal,"gaskets are not compatible and cannot be used with the FireLock EZT"couplings. • • • 10.64 7072 Rev L Updated 08/2017 ©2017 Victaulic Company.All rights reserved. a ctattlic,c rrl 3 Nictaulid' victaulic.com 5.0 PERFORMANCE6 Listings/Approval III The information provided below is based on the latest listing and approval data at the time of publication. Listings/Approvals are subject to change and/or additions by the approvals agencies. Contact Victaulic for performance on other pipe and the latest listings and approvals. Nominal Size cULus1' FM Vds Sch.5 Sch. 10 Sch.40 Sch.5 i Sch.10 Sch.40 i inches psi psi psi psi ' psi psi psi psi mm kPa kPa kPa kPa kPa kPa kPa kPa 11/4 232 365 365 175 363 363 363 363 32 1600 2517 2517 1205 2502 2502 2500 2500 11/2 232 365 365 175 363 363 363 363 40 1600 2517 2517 1205 2502 2502 2500 2500 2 363 365 365 175 363 363 363 363 50 2502 2517 2517 1205 2502 2502 2500 2500 21/2N/A 365 365 175 363 363 363 363 65 2517 2517 1205 2502 2502 2500 2500 76.1 mm N/A 3656 N/A N/A 363' 363 363 N/A 25176 2502' 2500 2500 3 N/A 365 365 175 363 363 363 363 80 2517 2517 1205 2502 2502 2500 2500 4 365 365 175 363 363 363 t 363 100 N/A 2517 2517 1205 2502 2502 2500 2500 108.0 mm N/A N/A N/A 175 363 363 N/A N/A 1205 2502 2502 5 290365 z— N/A 363 363 232 - N/A 125 N/A 2000 2517 2502 2502 1600 133.0 mm N/A N/A N/A i N/A 3637 N/A N/A N/A 139.7 mm N/A 2OOOOa N/A i N/A 36 2 032' N/A 1250 N/A 159.0 mm N/A N/A N/A N/A 25027 N/A N/A N/A ' 9 363' _ • 165.1 mm N/A 20009 N/A N/A 2502' N/A N/A N/A 6 N/A 290 365 N/A 363 363 232 N/A 150 2000 2517 ; 2502 2502 1600 , 216.0 mm N/A N/A N/A N/A 363' 9q 2502 N/A N/A ' i N/ A 8N/A 290 365 i N/A 363 363 232 N/A 200 2000 2517 2502 2502 1600 216.0 mm N/A N/A N/AN/A 250' N/A N/A N/A I 8 290 365 363 363 232 200 N/A 2000 2517 1 N/A 2502 2502 1600 N/A T. 10N/A 300 300 N/A 300 300 N/A .". N/A 250 2068 2068 2068 2068 12 N/A 30010 300 N/A 250 300 N/A N/A 300 206810 2068 i 1724 2068 Listed/Approved-for wet. . : :':- - - ,e' . • n freezing condd e•- --e • - -al • • •'•• '• .. •:• • et is recommended. Please see the Victaulic Installation Manual I-009N/009H for details concerning when supplemental lubrication is required. 6 cULus listed for DIN 2458 2.6 mm pipe wall. 7 FM approved for BS 1387 Medium 3.6 mm pipe wall. 8 cULus listed for EN 10220 4.0 mm pipe wall. 9 cULus listed for EN 10255 4.5 mm pipe wall. 1° cUL listed to 250 psi. ii With optional stainless steel fasteners,cULus Listed to 175psi.The stainless steel fasteners have a marking designation of"316°on the end face of the bolt. • • • 10.64 7072 Rev L Updated 08/2017 0 2017 Victaulic Company.All rights reserved. victaulic.com4 ✓ctau6c" victaulic.com 5.1 PERFORMANCE2 • Listings/Approval Speciality Pipe Pipe Size ! Pressure Rating Pipe Size ' Pressure Rating Pipe Size Pressure Rating cULus FM ; cULus FM cULus 1 FM inches psi psi inches psi psi inches psi I psi kPa kPa kPa kPa kPa ' kPa BLT 1 Ya 2 300 365 EZT 1„a 2 300 365 MT 1,/a 2 300 365 2068 2517 2068 2517 2068 2517 DF 11/4-4 300 365 FF 11/a-4 300 365 MLT 1 11/a-2 N/A 365 2068 2517 2068 2517 2517 r 300 365 365 365 i DT 1'/a-2 1/a 4 N/A ST 1/a 2 N/A 2068 2517 FLF 1 2517 , 2517 EF 1 1/a-4 175 175 FLT 1 Ya-2 N/A 365 STF 1 1/a-4 N/A 365 1206 1206 2517 2517 300 T. 365 365 365 EL 11/4-2 FLTL 11/4 2 N/A IF 21/4 4 N/A 2068 2517 2517 - 2517 ET40 1 1/a 2 300 365 GL 1 Ya 2 300 i 365 WLS 11/a 2 300 365 2068 ! 2517 2068 2517 2068 2517 EZF 3-4 300 365 11/4-4 300 365 ''WST 11/4-2 N/A 365 2068 2517 MF 2068 2517 ; ,. 2517 6 1 175 175 XL 1'/a 2 300 365 1205 1205 2068 2517 NOTES • BLT=BLT steel pipe manufactured by Allied Tube&Conduit Corp. • DF=DYNA-FLOW steel pipe manufactured by Allied Tube&Conduit Corp. • DT=DYNA-FLOW steel pipe manufactured by Allied Tube&Conduit Corp. • EF=EDDY FLOW steel pipe manufactured by Bull Moose Tube Co. • EL=EDDYLITE steel pipe manufactured by Bull Moose Tube Co. • ET40=Eddythread 40 steel pipe manufactured by Bull Moose Tube Co. • EZF=EZ-Flow steel pipe manufactured by Northwest Pipe Co. III • EZT=EZ-Thread steel pipe manufactured by Youngstown Tube Co. • FF=Fire-Flo steel pipe manufactured by Youngstown Tube Co. • FLF=Fire-Line Flow steel pipe manufactured by Western International Forest Products Inc. • FLT=Fire-Line Threadable steel pipe manufactured by Western International Forest Products Inc. • FLTL=Fire-Line Threadable Light steel pipe manufactured by Western International Forest Products Inc. • GL=GL steel pipe manufactured by Wheatland Tube Co. • MF=Mega-Flow steel pipe manufactured by Wheatland Tube Co. • MT=Mega-Thread steel pipe manufactured by Wheatland Tube Co. • MLT=MLT steel pipe manufactured by Wheatland Tube Co • ST=STD wall pipe in accordance with ASTM A53. • STF=Steady Flow steel pipe manufactured by AMS Tube Corp. • TF=Tex-Flow steel pipe manufactured by Tex-Tube Co. • WLS=WLS steel pipe manufactured by Wheatland Tube Co. • WST=WST steel pipe manufactured by Wheatland Tube Company. • XL=XL steel pipe manufactured by Allied Tube&Conduit Corp. III • 10.64 7072 Rev L Updated 08/2017 0 2017 Victaulic Company.All rights reserved. victaulic.com5 ✓ctaulrc° victaulic.com • • 6.0 NOTIFICATIONS Not applicable—contact Victaulic with any questions. 111/ 7.0 REFERENCE MATERIALS 05.01:Seal Selection Guide l-009N/009H:Installation Instructions FireLock EZTM Rigid Coupling • • • User Responsibility for Product Selection and Suitability Note Each user bears final responsibility for making a determination as to the suitability of This product shall be manufactured by Victaulic or to Victaulic specifications.All products Victaulic products for a particular end-use application,in accordance with industry to be installed in accordance with current Victaulic installation/assembly instructions. standards and project specifications,and the applicable building codes and related Victaulic reserves the right to change product specifications,designs and standard regulations as well as Victaulic performance,maintenance,safety,and warning equipment without notice and without incurring obligations. instructions.Nothing in this or any other document,nor any verbal recommendation, Installation advice,or opinion from any Victaulic employee,shall be deemed to alter,vary,supersede, Reference should always be made to the Victaulic installation handbook or installation or waive any provision of Victaulic Company's standard conditions of sale,installation instructions of the product you are installing.Handbooks are included with each shipment guide,or this disclaimer. of Victaulic products,providing complete installation and assembly data,and are available Intellectual Property Rights in PDF format on our website at www.victaulic.com. No statement contained herein concerning a possible or suggested use of any material, Warranty product,service,or design is intended,or should be constructed,to grant any license Refer to the Warranty section of the current Price List or contact Victaulic for details. under any patent or other intellectual property right of Victaulic or any of its subsidiaries or affiliates covering such use or design,or as a recommendation for the use of such Trademarks material,product,service,or design in the infringement of any patent or other intellectual Victaulic and all other Victaulic marks are the trademarks or registered trademarks of property right.The terms"Patented"or"Patent Pending"refer to design or utility patents Victaulic Company,and/or its affiliated entities,in the U.S.and/or other countries. or patent applications for articles and/or methods of use in the United States and/or other • countries. • • 10.64 7072 Rev L Updated 08/2017 ©2017 Victaulic Company.All rights reserved. victaulic.com 6 ✓ctauLc" Victaulic® Flexible Coupling ✓ctaul,c • Style 75 06.05 • 1-8YDN25—DN200 Exaggerated for clarity 1.0 PRODUCT DESCRIPTION Available Sizes • 1 —8"/DN25— DN200 Pipe Material • Carbon steel • Stainless steel Maximum Working Pressure • Accommodates pressures ranging from full vacuum (29.9 in Hg/760 mm Hg) up to 500 psi/3447 kPa/34 bar • Working pressure dependent on material, wall thickness and size of pipe Application • Joins standard roll grooved and cut grooved pipe, as well as grooved fittings, valves and accessories • Provides a flexible pipe joint which allows for expansion, contraction and deflection • • Up to 50% lighter in weight than standard Victaulic Style 77 or Style 177N flexible couplings 2.0 CERTIFICATION/LISTINGS cO. VdS 001 �P NOTES • Download publication 10.01 for Fire Protection Certifications/Listings Reference Guide. • See publication 02.06.Victaulic Potable Water Approvals ANSI/NSF for potable water approvals if applicable. ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION,MAINTENANCE OR SUPPORT. System No. I 1 Location I ( 1 Spec Section Paragraph I Submitted By 1 1 Date1 1 Approved I Date • victaulic.com 06.05 1470 Rev P Updated 10/2017 ©2017 Victaulic Company.All rights reserved. 1 ictauIie victaulic.com 3.0 SPECIFICATIONS—MATERIAL Housing: Ductile iron conforming to ASTM A536, Grade 65-45-12. Ductile iron conforming to ASTM A395, Grade • 65-45-15, is available upon special request. Housing Coating:(specify choice) ❑ Standard: Orange enamel ❑ Optional: Hot dipped galvanized ❑ Optional: Contact Victaulic with your requirements for other coatings. Gasket: (specify choicer) ❑ Grade "E" EPDM EPDM (Green stripe color code).Temperature range—30°F to+230°F/-34°C to+110°C. May be specified for hot water service within the specified temperature range plus a variety of dilute acids, oil-free air and many chemical services. UL Classified in accordance with ANSI/NSF 61 for cold +73°F/+23°C and hot+180°F/+82°C potable water service and ANSI/NSF 372. NOT COMPATIBLE FOR USE WITH PETROLEUM SERVICES OR STEAM SERVICES. ❑ Grade"T" Nitrile Nitrile(Orange stripe color code). Temperature range—20°F to+180°F/-29°C to+82°C. May be specified for petroleum products, air with oil vapors, vegetable and mineral oils within the specified temperature range; not compatible for hot dry air over+140°F/+60°C and water over+150°F/+66°C. NOT COMPATIBLE FOR USE WITH HOT WATER. ❑ Others For alternate gasket selection, reference publication 05.01: Victaulic Seal Selection Guide- Elastomeric Seal Construction. I Services listed are General Service Guidelines only.It should be noted that there are services for which these gaskets are not compatible.Reference should always be made to the latest Victaulic Seal Selection Guide for specific gasket service guidelines and for a listing of services which are not compatible. Bolts/Nuts:(specify choice2) ❑ Standard:Carbon steel oval neck track bolts meeting the mechanical property requirements of ASTM A449(imperial) and ISO 898-1 Class 9.8(metric). Carbon steel hex nuts meeting the mechanical property requirements of ASTM • A563 Grade B (imperial - heavy hex nuts)and ASTM A563M Class 9 (metric- hex nuts). Track bolts and hex nuts are zinc electroplated per ASTM B633 ZN/FE5,finish Type III(imperial)or Type II (metric). ❑ Optional (imperial): Stainless steel oval neck track bolts meeting the mechanical property requirements of ASTM F593, Group 2 (316 stainless steel), condition CW. Stainless steel heavy nuts meeting the mechanical property requirements of ASTM F594, Group 2(316 stainless steel), condition CW,with galling reducing coating. Optional bolts/nuts are available in imperial sizes only. • • • 06.05 1470 Rev P Updated 10/2017 ®2017 Victaulic Company.All rights reserved. victaulic.com 2 ✓ctaulic' victaulic.com 4.0 DIMENSIONS III Style 75 < Y 31 �Z-►I rr i''1 r:� irgi IIlI II l ��i 11x1 1 Pipe End 1 Deflection from I Size ' Separation3 ! Centerline3 Bolt/Nut Dimensions Weight Actual Outside I Approx. Nominal Diameter Allowable Per Cplg. Pipe Qty. Size X Y I Z (Each) inches 'inches . inches inches/ft. i imperial inches inches inches lb DN mm mm Degrees mm/m metric mm mm mm kg 1 1.315 0-0.060.57 3/s x 2 2.38 4.27 1.77 1.3 DN25 33.7 0-1.6 2°�3 48 2 M10 x 51 61 108 . 45 0.6 1 1/4 1.660 0-0.0620-10, 0.45 2 3/8 x 2 2.68 4.61 1 1.77 1.4 DN32 42.4 0-1.6 ° 38 M10 x 51 68 117 45 0.6 1 1/z 1.900 0-0.06 4 3/a 0.40 x 2 2.91 4.82 1.77 1.5 1 DN40 48.3 0-1.6 j 1 56' 33 2 M10 x 51 74 122 45 0.6 1 2 2.375 0-0.0610-31' 0.32 2 1/2x 2 3.43 5.22 ( 1.88 1.7 DN50 60.3 0-1.6 26 M10 x 51 87 133 i 48 0.8 21, 2.875 0-0.060.26 3/8 x 2 3,88 5.68 1.88 1.9 73.0 0-1.6 1°-15' 22 2 M10 x 51 98 144 •480.9 1 3.000 0-0.06 1° 12 0.26 2 3' x 2 4.00 5.90 1.88 1.9 DN65 76.1 0-1.6 22 M10 x51 102 150 48 0.9 3 3.500 0-0.06 1 2' 0.22 ... i 2 1/2 x 2 3/4 4.50 7.00 1.88 2.9 DN80 88.9 0-1.6 ;11 ° 18 ..'-' M l/x 70 114 178 48 1.3 3 1/2 4.000 0-0.06 0.19 1/2 x 2 Si 5.00 7.50 1.88 2.9 1 DN90 101.6 0-1.6 ; 0°54 16 2 M12 x 70 127 191 48 1.3 IPC 4 4.500 0-0.13 :i 0.34 Y2 x 2 3/4 5.80 8.03 2.13 4.1 DN 100 114.3 0-3.2 1°-36' 28 2 M12 x 70 147 204 54 i 1.9 4.250 0-0.13 , 0.35 1/2x 2 3/4 5.55 7.79 2.13 3.7 108.0 0-3.2 1° 41 29 2 M12 x 70 141 198 54 1.7 5.000 0-0.13 0.25 ;' 2_ 5/s x 3 1/4 6.13 9.43 2.13 5.5 1°-26' 1 ,. 127.0 0-3.2 F., 21 . M16 x 83 156 240 54 2.5 5 5.563 0-0.13 ! 0.27 I Vs x 31/4 I 6.88 10.07 2.13 5.8 141.3 0-3.2 ; 1°-18 23 2 M16 x 83 i 175 256 54 2.6 5.250 0-0.13 1 ; 1°_21, 0.28 r 2 5/8x3' 6.55 9.37 2.13 6.0 133.0 0-3.2 1...', 24 M16 x 83 `' 166 238 54 2.7 5.500 0-0.13 1 .10_18, 0.28 2 5/s x 3 1/4 6.80 9.59 2.13 6.3 DN 125 139.7 0-3.2 24 M16 x 83 173 244 54 2.9 6.000 0-0.13 1° 12' 0.21 2 5' x 31/4 j 7.38 10.48 1.88 6.2 l i 152.4 0-3.2 .r . 18 M16 x 83 i-' 187 266 48 2.8 i 6 I 6.625 0-0.131.-5' 0.23 1 2 I %x 314 8.00 11.07 2.13 7.0 DN150 1 168.3 0-3.2 I 18 M16 x 83 203 281 54 3.2 i 17.-__ I 6.250 0-0.13 10 -9, 4 - 0.24 ' 2 54 x 3 1/4 7.63 10.49 2.13 6.8 I 159.0 0-3.2 -,,1,,: i L... 20� M16 x 83 1 194 266 54 3.1 6.500 0-0.13 ,,, 0.23 /s x 3/4 7.84 10.66 2.08 6.6 ` 165.1 0-3.2 ! 10 7 ' 58 2 M16x83 199 271 53 3.0 ,.1 8.515 0-0.13 ;" 1 0.18' ,; 3/4 x 41/4 -�' 10.19 13.75 2.32 ' 13.2 i ' 216.3 0-3.2 1 0°-51' 46 2 M20 x 108 ` 259 350 59 6.0 1 r 88.625 0-0.13 0.18 I 3/4 x 41/4 1034 13.97 2.13 12.4 1 DN200 1 219.1 0-3.2 -50 � 14 2 , M20 x 108 263 � 355 i 59 i 5.6 3 Allowable Pipe End Separation and Deflection figures show the maximum nominal range of movement available at each joint for standard roll grooved pipe. Figures for standard cut grooved pipe may be doubled.These figures are maximums;for design and installation purposes these figures should be reduced by: 50%for 3/4-3 1/2"/DN20-DN90;25%for 4"/DN 100 and larger. NOTE • Metric thread size bolts are available(color coded gold)for all coupling sizes upon request.Contact Victaulic for details. 111 s • 06.05 1470 Rev P Updated 10/2017 ®2017 Victaulic Company.All rights reserved. aictaulic.com 3 Jctaulic" victaulic.com • 5.0 PERFORMANCE Style 75 III Size Actual Maximum Outside Working Maximum Nominal Diameter Pressure4 End Load4 inches ' inches psi lb DN mm kPa N 1 1.315 500 680 DN25 33.7 3447 3,025 11/4 1.660 500 1080 DN32 I 42.4 3447 4,805 11/2 1.900 500 1420 DN40 48.3 3447 6,320 2 f 2.375 500 2215 DN50 60.3 3447 9,860 2Y ± 2.875 ` , '`4 500 3245 73.0 "'.:` 3447 '.: . 14,440 3.000 500 3535 DN65 76.1 `i 3447 15,730 3 „„ S00 4800 3.500 DN80 ”"" . 889 _ 3447 21,360 3'/z E 4.000 500 6300 DN90 i 101.6 3447 28,035 4 4.500 500 7950 �.:u ,,. DN100 .n�.: 1143 „` 3447 35,380 „.x. . 4.250 I 450 6380 108.0 3103 28,395 5 000 450 8820 1270 ,,v 3103 39,250 5 5.563 450 10935 141.3 3103 48,660 • �' S 250 450 9735 133.0 3103 ��� 43,325 5.500 450 10665 DN125 139.7 3103 47,460 6000 ? 152 4 '> - .. 3103 3 56,670 6 6.625 450 15525 DN150 f 168.3 3103 69,085 ` " 6250 450 13800 , 159 0 3103 61,405 6.500 450 14930 165.1 3103 I 66,412 8 515 450 25625 216 3 3103 113,986 $--W______. 8.625 � —�_ 450 j 26280 DN200 219.1 I 3103 I 116,945 ^ Working Pressure and End Load aretotat,from all Internal and external ludas,based on ANSI B36.10 sized carbon steel pipe,gruuved in au.urdarrce with Victaulic specifications.Contact Victaulic for performance on other pipe. NOTE • WARNING:FOR ONE TIME FIELD TEST ONLY,the Maximum Joint Working Pressure may be increased to 11 times the figures shown. • • • 06.05 1470 Rev P Updated 10/2017 ©2017 Victaulic Company.All rights reserved. victaulic.com 4 ✓ctaulic victaulic.com • • 6.0 NOTIFICATIONS • WARNING I • Victaulic RX roll sets must be used when grooving light-wall/thin-wall stainless steel pipe for use with Victaulic Couplings. I Failure to use Victaulic RX roll sets when grooving light-wall/thin-wall stainless steel pipe may cause joint failure, I resulting in serious personal injury and/or property damage. NOTICE • Victaulic RX grooving rolls must be ordered separately.They are identified by a silver color and the designation RX on the front of the roll sets. 7.0 REFERENCE MATERIALS 02,06:Victaulic(Si Potable Water Approvals ANSI/NSF 05.01:Victaulic®Seal Selection Guide-Elastomeric Seal Construction 06.15:Victaulic®Pressure Ratings and End Loads for Victaulic Couplings on Steel Pipe 10.01 Victaulic®Products for Fire Protection Pipings Systems-Regulatory Approval Reference Guide 17.01:Victaulic®Pipe Preparation for Use on Stainless Steel Pipe With Victaulic Products 17.09:Victaulic®Ductile Iron Grooved Couplings Performance Data for Stainless Steel Pipe 25.01:Victaulic®Standard Groove Specifications 26.01:Victaulic®Design Data 29.01:Victaulic®Terms and Conditions of Sale 1400:Victaulic®Field Installation Handbook • • User Responsibility for Product Selection and Suitability Note Each user bears final responsibility for making a determination as to the suitability of This product shall be manufactured by Victaulic or to Victaulic specifications.All products Victaulic products for a particular end-use application,in accordance with industry to be installed in accordance with current Victaulic installation/assembly instructions, standards and project specifications,and the applicable building codes and related Victaulic reserves the right to change product specifications,designs and standard regulations as well as Victaulic performance,maintenance,safety,and warning equipment without notice and without incurring obligations. instructions.Nothing in this or any other document,nor any verbal recommendation, Installation advice,or opinion from any Victaulic employee,shall be deemed to alter,vary,supersede, Reference should always be made to the Victaulic installation handbook or installation or waive any provision of Victaulic Company's standard conditions of sale,installation instructions of the product you are installing.Handbooks are included with each shipment guide,or this disclaimer. of Victaulic products,providing complete installation and assembly data,and are available Intellectual Property Rights in PDF format on our website at www.victaulic.com. No statement contained herein concerning a possible or suggested use of any material, Warranty product,service,or design is intended,or should be constructed,to grant any license Refer to the Warranty section of the current Price List or contact Victaulic for details. under any patent or other intellectual property right of Victaulic or any of its subsidiaries or affiliates covering such use or design,or as a recommendation for the use of such Trademarks material.product,service,or design in the infringement of any patent or other intellectual Victaulic and all other Victaulic marks are the trademarks or registered trademarks of • Property right.The terms"Patented"or"Patent Pending"refer to design or utility patents Victaulic Company,and/or its affiliated entities,in the U.S.and/or other countries. or patent applications for articles and/or methods of use in the United States and/or other countries. • • 06.05 1470 Rev P Updated 10/2017 ®2017 Victaulic Company.All rights reserved. victaulic.com 5 \ictaulic Victaulic® Reducing Coupling ✓ctau, cr Style 750 06.08 • ihl 1.0 PRODUCT DESCRIPTION Available Sizes: • 2 x 1" through 10 x 8"/DN50 x DN25 through DN250 x DN200 Pipe Material: • Carbon steel Maximum Working Pressure: • Up to 500 psi/3447 kPa • Working pressure dependent on material, wall thickness and size of pipe Application: • Joins OGS roll grooved and cut grooved pipe, as well as OGS grooved fittings, valves and accessories • Permits direct reduction on piping run • Optional steel washer prevents telescoping of the smaller pipe inside the larger pipe during vertical system assembly Pipe Preparation: • Cut or roll grooved in accordance with publication 25.01: Victaulic Standard Groove Specifications. • 2.0 CERTIFICATION/LISTINGS • 401> was LPCBI �P NOTES • Download publication 10.01 for Fire Protection Certifications/Listings Reference Guide. ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION,MAINTENANCE OR SUPPORT. System No. Location ' Spec Section Paragraph Submitted By Date I LApproved Date victaulic.com 06.08 1536 Rev L Updated 10/2017 ©2017 Victaulic Company.At rights reserved. 1 .ctau6c victaulic.com 3.0 SPECIFICATIONS—MATERIAL • • Housing: Ductile iron conforming to ASTM A536, Grade 65-45-12. Ductile iron conforming to ASTM A395, Grade 65-45-15, is available upon special request. Housing Coating:(specify choice) • Standard: Orange enamel. O Optional: Hot dipped galvanized conforming to ASTM A153. O Optional: Contact Victaulic with your requirements. Gasket:(specify choice') O Grade"E" EPDM EPDM (Green stripe color code). Temperature range—30°F to+230°F/-34°C to+110°C. May be specified for hot water service within the specified temperature range plus a variety of dilute acids, oil-free air and many chemical services. UL Classified in accordance with ANSI/NSF 61 for cold +73°F/+23°C and hot+180°F/+82°C potable water service and ANSI/NSF 372. NOT COMPATIBLE FOR USE WITH PETROLEUM SERVICES OR STEAM SERVICES. • Grade"T" Nitrile Nitrile (Orange stripe color code). Temperature range—20°F to+180°F/-29°C to+82°C. May be specified for petroleum products, hydrocarbons,air with oil vapors,vegetable and mineral oils within the specified temperature range; not compatible for hot dry air over+140°F/+60°C and water over+150°F/+66°C. NOT COMPATIBLE FOR USE WITH HOT WATER SERVICES OR STEAM SERVICES. Others O For alternate gasket selection, reference publication 05.01:Victaulic Seal Selection Guide. Services listed are General Service Guidelines only.It should be noted that there are services for which these gaskets are not compatible.Reference should always be made to the latest Victaulic Seal Selection Guide for specific gasket service guidelines and for a listing of services which are not compatible. Bolts/Nuts(specify choice2): • Standard: Carbon steel oval neck track bolts meeting the mechanical property requirements of ASTM • A449 (imperial)and ISO 898-1 Class 9.8(metric). Carbon steel hex nuts meeting the mechanical property requirements of ASTM A563 Grade B (imperial—heavy hex nuts)and ASTM A563M Class 9 (metric—hex nuts). Track bolts and hex nuts are zinc electroplated per ASTM B633 ZN/FE5,finish Type III (imperial) or Type II (metric). O Optional (imperial): Stainless steel oval neck track bolts meeting the mechanical property requirements of ASTM F593, Group 2 (316 stainless steel), condition CW. Stainless steel heavy nuts meeting the mechanical property requirements of ASTM F594, Group 2 (316 stainless steel), condition CW, with galling reducing coating. Assembly Washer(optional): Galvanized carbon steel. 2 Optional bolts/nuts are available in imperial size only • • • 06.08 1536 Rev L Updated 10/2017 ©2017 Victaulic Company.All rights reserved. victaulic.com2 ✓ctaulic' victaulic.corn 4.0 DIMENSIONS Style 750 III Y ,{ I-K-2-2 1141rii U.\1 if-RI rt i.1 iiliFAh:1111Sh.m., IfMl 0,1 i ( Li -1- •••%741.....7 I Ni N� 1 r Pipe End Size Separation Deflect.From CL3 Bolt/Nut Dimensions Weight 1 I Approximate Nominal I Allowable Per Cplg. Pipe Qty. Size X Y Z (Each) inches inches In./Ft. inches inches inches inches lb DN mm Degrees mm/m mm mm mm mm kg 2 1 0-0.07 0.20 3.38 5.28 1.88 2.7 DN50 x DN25 0-1.8 0°-57 17 2 3/8 x 2 85 134 48 1.2 11/2 0-0.070.20 3.38 5.28 1.88 2.0 DN40 0 1.8 0°-57' 17 2 3/8 x 2 85 134 481.0 2 Y 2 0-0.07 0.16 4.00 1 5.93 1.88 = 3.1 x 0°-47' 2 3/8 x 2 DN50 0-1.8 14 102 i 151 48 1.4 2 0-0.07 0.16 4.38 „".I 6.63 ':' 1.88 -= 4.6 x 0° 47 , 2 1/2 x 23/4 DN65 DN50 0 1.8 14 111 168 48 , 2.1 07 0.13 4.75 7.13 1.88 E 4.9 8 0° 39' 11 2 i Y2 x 23/a DN80 x DN50 0- 121 181 48 2.2 2 1/2 0-0.07 0.13 4.75 7.13 1.88 4.3 0-1.8 0°-39' 11 2 'h x 2�a 121 181 48 2.0 _ 0-0.07 4.2 0°-39' 0.13 2 h x 2 3/4 4.75 7.13 1.88 DN65 0-1.8 11 121 181 48 1.9 4 2 0-0.13 0.28 6.25 71 8.90 2.25 8.1 - • - x 1° 19 2 s/e x 3 Y4 DN100 DN50 0-3.2 `^, n, 25 159 226 . '' 57 3.7 21/z 0-0.13 ? 0.28 6.25 8.90 2.25 8.6 1° 19 2 Y• x 31/4 0-3.2 1 25 1591 226 57 3.9 0-0.13 I . 0.28 6.25 i 8.90 2.25 6.9 1° 19 = 2 5/8 x 31/4 i DN65 0-3.2 i_ 25 159 226 57 3.1 ' I ,. 3 0-0.13 j 0.28 6.00 8.90 2.25 6.7 :t 1° 19 2 s/s x 3 1/a DN80 0-3.2 =` 25 152I''' 226 57 3.0 I 5 7.18 10.70 2.13 11.2 x 1 1 3' 2 3/4 x 4/a DN100 0-3.2 19 182 272 54 5.1 4 0-0.13 0.19 8.63 11.90 2.25 15.2 x0° 55' 2 Si x 41/4 165.1 DN100 0-3.2 - 16 219 ', 302 - 57 6.9 ' 6 4 0-0.13 i 0.18 8.63 11.90 2.25 16.7 i x DN700 0°-52' 3/4 2 x 4'/4 DN150 0-3.2 15 219 302 57 7.6 5 i 0-0.13 I 0.18 8.31 11.90 2.25 12.9 ' 3 - 0-3.2 15 2 /4 x 4/4 211 302 57 5.9 .8 X ' ` 0-0.13 ' 0.13I. 10.75 14.88 2.50 23.2 j ' 165.1 0-3.2 11 2 s x 5 273 f 378 i 64 10.5 } 6 0-0.13 -I , ` 0.13 ,._. 10.81 ;. 14.88 2.50 22.4 DN150 0-3.2 ,, ., ,.s 11 2 a x 5 275 i.,:; 378 64 10.2 10 8 0-0.13 0.90 13.12 17.26 2.62 31.4 1 I DN250 x DN200 0-3.2 E 0°-25 1 8 1 2 1 x 5 Yz; 333 438 ( 67 14.2 3 Allowable Pipe End Separation and Deflection figures show the maximum nominal range of movement available at each joint for standard roll grooved pipe. Figures for standard cut grooved pipe may be doubled.These figures are maximums;for design and installation purposes,these figures should be reduced by: 50%for 3/4-3' /DN20-DN90;and 25%for 4'/DN100 and larger. NOTE • Metric thread size bolts are avaialble(colord-coded gold)for all coupling sizes upon request.Contact Victaulic for details. • • • 06.08 1536 Rev L Updated 10/2017 ©2017 Victaulic Company.All rights reserved. victaulic.com 3 ✓ctaulic victaulic.com 5.0 PERFORMANCE • Style 750 Size Maximum Maximum Working End Nominal Pressure4 Load4 inches psi lb DN kPa N 2 1 350 500 DN50 x DN25 2413 2,225 1 1/2 350 1000 DN40 2413 4,450 2 1/2 2 500 2215 x DN50 3447 9,850 2 350 1550 ,i DN65 x DNSO 2413 6,900 3 2 350 1550 DN80 x DN50 2413 6,900 216 500 j 3250 3447 I 14,460 350 I 2475 DN65 2413 11,010 4 2 350 1550 DN100 x DN50 2413 6,900 2 1/2 350 2275 2413 10,125 350 2475 DN65 2413 11,014 3 500 4810 DN80 3447 21,400 5 4 350 5565 III 6 x DN100 2413 24,765 4 350 5565 DN150 x DN100 2413 24,765 5 350 8500 2413 37,825 8 _.. 350 11610 DN200 x 165.1 2413 51,645 6 350 12060 DN150 2413 53,645 10 8 350 20450 DN250 x DN200 2413 90,970 4 Working Presssure and End Load are total,from all internal and external loads,based on standard weight(ANSI)steel pipe,standard roll or cut grooved in accordance with Victaulic specifications.Contact Victaulic for performance on other pipe and material.Maximum working pressure rating based on larger pipe size.Maximum end load rating based on smaller pipe size. NOTES • WARNING:FOR ONE-TIME FIELD USE ONLY,the Maximum Joint Working Pressure may be increased to 1' times the figures shown. • For joint pressure ratings on additional carbon steel wall thicknesses,see publication 06.15. • , • 06.08 1536 Rev L Updated 10/2017 CO 2017 Victaulic Company.All rights reserved. victaulic.com 4 ✓ctau6d victaulic.com • • 6.0 NOTIFICATIONS ®oo A WARNING , 1p 110 • Read and understand all instructions before attempting to install,remove,adjust,or maintain any Victaulic piping products. • Depressurize and drain the piping system before attempting to install, remove,adjust,or maintain any Victaulic piping products. • Wear safety glasses, hardhat,and foot protection. • Only No.61 bull plugs shall be used with Style 750 reducing couplings in systems where a vacuum may develop. Failure to follow these instructions could result in death or serious personal injury and property damage. 7.0 REFERENCE MATERIALS 05.01:Victaulic®Seal Selection Guid:. 10.01:Victaulic®Products for Fire Protection Pining Systems-Regulatory Approval Reference Guide 25.01:Victaulic®Original Groove System(OGS)Groove Specifications 26.01:Victaulic®Design Data 29.01:Victaulic®Terms and Conditions of Sale 1-100:Victaulic®Field Installation Handbook • • • User Responsibility for Product Selection and Suitability Note Each user bears final responsibility for making a determination as to the suitability of This product shall be manufactured by Victaulic or to Victaulic specifications.All products Victaulic products for a particular end-use application,in accordance with industry to be installed in accordance with current Victaulic installation/assembly instructions. standards and project specifications,and the applicable building codes and related Victaulic reserves the right to change product specifications,designs and standard regulations as well as Victaulic performance,maintenance,safety,and warning equipment without notice and without incurring obligations. instructions.Nothing in this or any other document,nor any verbal recommendation, Installation advice,or opinion from any Victaulic employee,shall be deemed to alter,vary,supersede, Reference should always be made to the Victaulic installation handbook or installation or waive any provision of Victaulic Company's standard conditions of sale,installation instructions of the product you are installing.Handbooks are included with each shipment guide,or this disclaimer. of Victaulic products,providing complete installation and assembly data,and are available Intellectual Property Rights in PDF format on our website at www.victaulic.com. No statement contained herein concerning a possible or suggested use of any material, Warranty product,service,or design is intended,or should be constructed,to grant any license Refer to the Warranty section of the current Price List or contact Victaulic for details. under any patent or other intellectual property right of Victaulic or any of its subsidiaries or affiliates covering such use or design,or as a recommendation for the use of such Trademarks material,product,service,or design in the infringement of any patent or other intellectual Victaulic and all other Victaulic marks are the trademarks or registered trademarks of property right.The terms"Patented"or"Patent Pending"refer to design or utility patents Victaulic Company,and/or its affiliated entities,in the U.S.and/or other countries. or patent applications for articles and/or methods of use in the United States and/or other • countries. 06.08 1536 Rev L Updated 10/2017 ©2017 Victaulic Company.All rights reserved. victaulic.com 6 ✓ctaulic` • ThreadedFittingsast Iron .,,, .. ,.,..,..... _ „ ,..,,,,.,..... ...,,. , „,„„.,, „, ....,,, ,, ,..,„,,,„4„,,,„.,,,.., .,., „,,,,,.„ ,, .,..,,,,,,,,,..:„.„,,,...„..,,,,,.„,,.,,,,,,, , ,„,,..„,..„,,......,„,..,...,,,..„..,,,,,,,,,,,;„,,„,,,,,..„..,,,,„...,..„.....,,,,„,„...,,....,,,..„.„ ., ,yk,,A,t;iiiiir4,.,4:..„,f„.:,...1,41t4.,,-;,,Ii.:,-,,,,,,!,4,,,,,*.E,-,44,e,„?.,t,...,.i'-.T.:4y'.;,...',,,',,t4',,'§'.....' i ,4,h, a b A 3 1€ "v 'u wm 4 �,a» ' to .,,, .'',,e,'::.,,;.::,.,„f� r ” 1 . 7trrts,. t fou, x ', °',. '� .nE k °x n, t.:R'meq`"' �'m� S ham • SMITHL CooE INTERNATIONAL • Cast Iron Threaded Fittings • ` %' branded cast iron threaded fittings are UL Listed and FM Approved at 300psi • Rated to 125#WSP • Casting date on each fitting C el US • Grey iron castings conform to ASTM A126 LISTED • Cast iron fitting dimensions conform to ASME B16.4 Class 125 • NPT threads on fittings conform to ASME B1.20.1 APPROVED • Cast iron fittings have SCI Trademark and are 100% air tested • Manufacturing facility is ISO 9001:2008 and ISO 14001 • • r Cast Iron Fittings - Class 125 UL/FM 7 444.6- c ® us • APPROVED Fig. 37E 1 -90°Elbow LISTED A Size A Packing Weight Part Number IN IN Inner Master LB 1/2 37E 1004 1.13 90 180 0.3 = h --r � 3/4 37E 1006 1.31 50 100 0.5 A i 1 37E 1010 1.50 35 70 0.8 e Ilk 1-1/4 37E 1012 1.75 20 40 1.3 1-1/2 37E 1014 1.94 15 30 1.7 2 37E 1020 2.25 7 14 2.7 2-1/2 37E 1024 2.70 4 8 4.3 Fig. 37RE1 - 90°Reducing Elbow Size A B Packing Weight E A �I IN Part Number IN IN Inner Master LB iiia1 x 1/2 37RE1010004 1.36 1.26 50 100 0.5 :___ 1 x 3/4 37RE1010006 1.45 1.38 40 80 0.7 1-1/4 x 1/2 37RE1012004 1.53 1.34 32 64 0.8 B 1-1/4 x 3/4 37RE1012006 1.63 1.45 28 56 0.9 i 1-1/4 x 1 37RE1012010 1.67 1.58 25 50 1.0 1-1/2 x 1/2 37RE1014004 1.75 1.52 25 50 1.0 1-1/2 x 3/4 378E1014006 1.75 1.52 20 40 1.1 1-1/2 x 1 37RE1014010 1.80 1.65 18 36 1.3 1-1/2 x 1-1/4 37RE1014012 1.88 1.82 14 28 1.5 2 x 1/2 37RE1020004 1.97 1.60 15 30 1.4 2 x 3/4 37RE1020006 1.97 1.60 15 30 1.6 2 x 1 37RE1020010 2.02 1.73 12 24 1.8 1110 2 x 1-1/2 37RE1020014 2.16 2.02 10 20 2.3 Fig. 37F 1 -45°Elbow Size A Packing Weight i , IN Part Number IN Inner Master LB 1 37F 1010 1.26 40 80 0.7 Ara 1-1/4 37F 1012 1.29 22 44 1.2 1-1/2 37F 1014 1.44 16 32 1.5 II�'�` 1V 2 37F 1020 1.69 8 16 2.6 C Fig. 37T 1 - Tee A Size A Packing Weight Part Number IN IN Inner Master LB S Onnals 1/2 37T 1004 1.13 60 120 0.4 T I -� 3/4 37T 1006 1.31 30 60 0.7 �I1 371 1010 1.50 20 40 1.1 1-1/4 37T 1012 1.75 12 24 1.8 R > 1-1/2 37T 1014 1.94 8 16 2.4 02 37T 1020 2.25 5 10 3.8 N V d Fig. 37RC1 -Hex Coupling Size Part Number A Packing Weight IN IN Inner Master LB W 1 x 1/2 37RC1010004 1.69 60 120 0.5 S .. 1 x 3/4 37RC1010006 1.69 50 100 0.6 4 2 x 1 (not hex)I 37RC1020010 I 2.81 I 16 I 32 I 1.5 97 SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX(323)890-4456 • www.smithcooper.com Cast Iron Fittings- Class 125 UL/FM CelUS APPROVED • Fig. 37RT1 -Reducing Tee LISTED Size part Number A B C Packing Weight 'tti�' IN IN IN IN Inner Master LB C 1 x 1/2 37RT1010004 1.26 1.26 1.36 25 50 0.9 • I___ .. 1 x 1/2 x 1 37RT1010004010 1.50 1.36 1.50 24 48 0.9 1 x 3/4 37RT1010006 1.38 1.38 1.45 22 44 1.0 I_- �I 1 x 3/4 x 1 37RT1010006010 1.50 1.45 1.50 20 40 1.0 1 x 1-1/4 37RT1010012 1.67 1.67 1.58 15 30 1.4 B 1-1/4 x 1/2 37RT1012004 1.34 1.34 1.53 18 36 1.3 1-1/4 x 1/2 x 1-1/4 37811012004012 1.75 1.53 1.75 18 36 1.4 1-1/4 x 3/4 37R11012006 1.45 1.45 1.62 15 30 1.4 1-1/4 x 3/4 x 1-1/4 37RT1012006012 1.75 1.62 1.75 15 30 1.5 1-1/4 x 1 37RT1012010 1.58 1.58 1.67 - 15 30 1.6 1-1/4 x 1 x 1/2 37RT1012010004 1.34 1.26 1.53 20 40 1.1 1-1/4 x 1 x 3/4 37RT1012010006 1.45 1.38 1.63 16 32 1.2 1-1/4 x 1 x 1 37R11012010010 1.58 1.50 1.69 15 30 1.4 1-1/4 x 1x;1-1/4 37R11012010012 1.75 1.69 1.75 12 24 1.6 1-1/4 x 1 x 1-1/2 37RT1012010014 1.88 1.80 1.82 12 24 1.8 1-1/4 x 1-1/2 37811012014 1.88 1.88 1.82 10 20 ; 2.0 1-1/2 x 1/2 37RT1014004 1.41 1.41 1.66 12 24 1.6 1-1/2 x 1/2 x 1-1/4 37RT1014004012 1.81 1.56 1.88 12 24 1.7 1-1/2 x 1/2 x 1-1/2 37RT1014004014 1.94 1.66 1.94 12 24 1.8 1-1/2 x 3/4 37RT1014006 1.52 1.52 1.75 12 24 1.8 1-1/2 x 3/4 x 1-1/4 37RT1014006012 1.94 1.66 1.88 12 24 1.7 1-1/2 x 3/4 x 1-1/2 37RT1014006014 1.94 1.75 1.94 12 24 1.9 1-1/2 x 1 37811014010 1.65 1.65 1.80 10 20 1.9 1-1/2 x 1 x 1/2 37811014010004 1.44 1.25 1.69 18 36 1.3 1-1/2 x 1 x 3/4 37811014010006 1.50 1.44 1.75 15 30 1.4 1-1/2 x 1 x 1 37811014010010 1.65 1.50 1.80 12 24 1.6 ill 1-1/2 x 1 x 1-1/4 37RT1014010012 1.82 1.67 1.88 10 20 1.8 1-1/2 x 1 x 1-1/2 37RT1014010014 1.94 1.80 1.94 8 16 2.1 1-1/2 x 1-1/4 37R11014012 1.82 1.82 1.88 8 16 2.2 1-1/2 x 1-1/4 x1/2 37RT1014012004 1.41 1.34 1.66 15 30 1.5 1-1/2 x 1-1/4 x 3/4 37RT1014012006 1.52 1.45 1.75 12 24 1.6 1-1/2 x 1-1/4 x 1 37R11-014012010 1.65 1.58 1.80 12 24 1.8 1-1/2 x 1-1/4 x 1-1/4 37RT1014012012 1.82 1.75 1.88 10 20 2.1 1-1/2 x 1-1/4 x 1-1/2 37RT1014012014 1.94 1.88 1.94 8 16 2.3 1-1/2 x 1-1/4 x 2 37RT1014012020 2.16 2.10 2.02 6 12 2.7 1-1/2 x 2 37RT1014020 2.16 2.16 2.02 5 10 2.9 2 x 1/2 37811020004 1.49 1.49 1.88 8 16 2.6 2 x 3/4 37R11020006 : 1.60 1.60 1.97 8 16 2.6 C 2 x 1 37811020010 1.73 1.73 2.02 6 12 2.9 A 2 x1 x 2 37811020010020 2.25 2.02 2.25 5 10 3.1 aS 2 x 1-1/4 37811020012 1.90 1.90 2.10 5 10 3.2 Z 2 x 1-1/4 x 2 37RT1020012020 2.25 2.10 2.25 5 10 3.2 2 x 1-1/2 37RT1020014 2.02 2.02 2.16 5 10 3.3 2 x 1-1/2 x 1/2 37RT1020014004 1.49 1.41 1.88 8 16 2.1 2 x 1-1/2 x 3/4 37RT1020014006 1.60 1.52 1.97 8 16 2.2 R 2 x 1-1/2x 1 37811020014010 1.73 1.65 2.02 8 16 2.4 2 x 1-1/2 x 1-1/4 37811020014012 1.90 1.82 2.10 7 14 2.7 N 2 x 1-1/2 x 1-1/2 37811020014014 2.02 ' 1.94 2.16 7 14 2.9 2 x 1-1/2 x 2 37RT1020014020 2.25 2.16 2.25 5 10 3.4 2 x 2-1/2 37RT1020024 2.60 2.60 2.39 3 6 4.6 • SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX(323)890-4456 • www.smithcooper.com 98 • Ductile Iron Threaded Fittings , _ , .• . . _ ....: ,... .. . .,... . . .,,.:.___ _ ‘ „„....,.... „. . , _ ., ,._ . , .,. ,. „.... . . ... . . . ... _ _ ..... ,, ,,,... . :, .. . . . .... . „ .. . ....: ..„. .,_ . . . •, . .. . ., „ _.- :Ti,: ::.• i.. .-,_*-:',":'- • .. ,..,... ,,,,k,,..: , . _ .„. r.A,' L , 9 Px_ 0 - . '-',‘. ,..,..",7,,,,,,,,,, 4 .,.,��.. tl .� `.,` ung •i a r r'', -;.: te. n z i�: as ;�«. - TH PEI SMI 6) • INTERNATIONAL Ductile Iran Threaded Fittings Specifications • CI branded ductile iron threaded fittings are UL Listed and FM Approved at 500 psi • Rated to 300 WSP c 101. us • Ductile iron castings conform to ASTM A536 LISTED • Fitting dimensions conform to ASME B16.3 • Bushings and plugs conform to ASME B16.14 • Fittings are 100% air tested APPROVED • NPT threads on all fittings conform to ASME B1.20.1 • Independent lab verification that fittings meet applicable chemical &physical properties • • Manufacturing facilities are ISO 9001:2008 and ISO 14001 Temperature Working Pressure, Nonshock psiG Degrees F 300# Class Threaded Fittings -20 to 100 500 150 500 200 480 250 �'����;���; � � "; 460 300 440 350 pcx 420 400 400 450 380 500 360 550 +r. 340 600 320 650 300 V. ,:- Ductile Iron Fittings - Class 300 UL/FM • cIDus APPROVED Fig. 35E 3-90°Elbow LISTED A Size Part Number A Packing _ Weight r; , �. � !�^\ in in Inner Master lb '" _ S 1/2 ( ��'�� __+ 35E 3004 1.13 100 200 Q2 1#R 3/4 35E 3006 1.31 70 140 0.3 ' A 1 35E 3010 1.50 40 80 0.5 �1.1111 1-1/4 35E 3012 1:75 25 50 0.8 1-1/2 35E 3014 1.94 18 36 1.1 2 35E 3020 2.25 10 20 1.8 2-1/2 35E 3024 2.70 4 8 3.2 Fig. 35RE3- 90°Reducing Elbow 4111 �) Size Part Number A B Packing Weight `.v` in in in Inner Master lb 314 x 1/2 35RE3006004 1.20 1.22 80 160 0.3 !l _ A 1x1/2 35RE3010004 1.26 1.36 70 140 0.4 1 x3/4 35RE3010006 1.38 1.45 50 100 0.4 1-1/4x 1/2 35RE3012004 1.34 1 53 35 70 0.5 1-1/4x3,/4 35RE3012006 1.45 1.63 35 70 0.6 1-1/4 x 1 35RE3012010 1.58 1,67 30 60 0.7 1-1/2x112 358E3014004 1.52 1.75 30 60 0.6 1-1/2 x 3/4 35RE3014006 1.52 1.75 25 50 0.7 1-1/2 x 1 35RE3014010 1.65 1.80 20 40 0.8 1-1/2 x 1-1/4 35RE3014012 1.82 1.88 18 36 1.0 2 x 1/2 35RE3020004 1.60 1.97 18 36 1.0 2 x 3/4 35RE3020006 1.60 1.97 18 36 1.0 2 x 1 35RE3020010 1.73 2.02 16 32 1.2 2 x 1-1/4 35R53020012 1.90 2.10 12 24 1.3 / 2 x 1-1/2 35RE3020014 2.02 2.16 10 20 1.5 1 2-1/2x 1-1/2 35RE3024014 2.16 2.51 6 12 2.2 2-1/2 x 2 35RE3024020 2.39 2.60 6 12 2.5 Fig. 35F 3-45°Elbow Size A Packing Weight Part Number A in in Inner Master lb ri ` \� 1/2 35F 3004 0.88 150 300 0.2 �� 3/4 35F 3006 0.98 80 160 0.3 \ 1 35F 3010 1.13 40 80 0.5 a 1-1/4 35F 3012 1.29 25 50 0.7 A 1-1/2 35F 3014 1.44 20 40 1.0 Min ., 2 35F 3020 1.69 10 20 1.6 2-1/2 35F 3024 1.95 4 8 2.7 Fig. 35T 3- Tee Size A Packing Weight i - Part Number in in Inner Master lb Ivy 1/2 a 35T 3004 1.13 80 160 0.3 A 3/4 35T 3006' 1.31 30 60 0 5 I1 III 1 35T 3010 1.50 25 50 0.7 1-1/4 35T 3012 1.75 10 20 1.1 *--A--)1< A'i< A ) 1-1/2 35T 3014 1.94 10 20 1.5 2 35T 3020 2.25 6 12 2.4 • 2-1/2 35T 3024 2.70 4 8 4.3 111 SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX(323)890-4456 • www.smithcooper.com I ucti e ron fittings- ass I i 1 / C � US APPROVED 1110 Fig. 35RT3-Reducing Tee LISTED __ Size A B C Packing Weight Part Number pl in in in in Inner Master lb i C 3!4 x 1/2 35813006004 1.20 1.20 1.22 60 120 0.4 bx 1/2 35813010004 1.26 1.26 1.36 30 60 0.6 -11 ~ - 1 x 1/2 x 1 35R13010004010 1.50 1.36 1.50 30 60 0.6 1 x 3/4 35873010006 1.38 1.38 1.45 25 50 0.6 i B ) A 1 x 3/4 x 3/4 35813010006006 1.38 1 31 1.45 35 70 0.6 1 x 3/4 x 1 35813010006010 1.50 1.45 1.50 25 50 0.7 1-1/4x1/2 35813012004 1.34 1.34 1.53 20 40 0.8 1-1/4 x 1/2 x 1-1/4 3581-3012004012 1.75 1,53 1.75 25 50 0.9 1-1/4 x 3/4 35813012006 1.45 1.45 1.62 15 30 0.9 1-1/4 x 3/4 x 1-1/4 35813012006012 1.75 1.62 1.75 20 40 1.0 1-1/4 x 1 35RT3012010 1.58 1.58 1.67 15 30 1.0 1-1/4 x 1 x 1/2 35813012010004 1.34 1.26 1.53 25 50 0.7 1-1/4 x 1 x 3/4 35813012010006 1.45 1.38 1.63 20 40 0.8 1-1/4-x 1 x 1 35RT3012010010 1.58 1.50 1.69 20 40 0.9 1-1/4 x 1 x 1-1/4 35RT3012010012 1.75 1.69 1.75 15 30 1.0 1-1/2 x 1/2 35813014004 1.41 1.41 1.66 16 32 1.0 1-1/2 x 1/2 x 1-1/4 35RT3014004012 1.81 1.56 1.88 24 48 1.1 1-1/2 x 1/2 x 1-1/2 35813014004014 1.94 1.66 1.94 12 24 1.2 1-1/2 x 3/4 35RT3014006 1.52 1.52 1.75 16 32 1.1 1-1/2 x3/4 x 1-1/4 35R13014006012 1.94 1.66 1.88 20 40 1.1 1-1/2 x 3/4 x 1-1/2 35813014006014 1.94 1.75 1.94 18 36 1.2 1-1/2 x 1 35813014010 1,65 1.65 1.80 12 24 1.2 1-1/2 x 1 x 1/2 35813014010004 1.44 1.25 1.69 20 40 0.8 1-1/2 x 1 x 314 35873014010006 1.50 1.44 1.75 16 32 0.9 1-1/2 x 1 x 1 35813014010010 1.65 1.50 1.80 16 32 1.0 III 1-1/2 x 1 x 1-1/4 35RT3014010012 1.82 1.67 1.88 12 24 12 1-1/2 x 1 x 1-1/2 35RT3014010014 1.94 1.80 1,94 12 24 1.3 1-1/2 x 1 1/4 35813014012 1.82 1.82 1.88 12 24 1.4 Irl 1-1/2 x 1-1/4 x 1/2 35813014012004 1.41 1.34 1.66 16 32 0.9 1-1/2 x 1-1/4 x 3/4 35R13014012006 1.52 1.45 1.75 16 32 1.0 `°, 1-1/2 x 1-1/4 x 1 35R13014012010 1.65 1.58 1.80 16 32 1.1 1-1/2 x 1-1/4 x 1-1/4 35R13014012012 1.82 1.75 1.88 14 28 1.3 1-1/2 x 1-1/4 x 1-1/2 35RT3014012014 1.94 1.88 1.94 14 28 1.4 2 x 1/2 35813020004 1.49 1.49 1.88 10 20 1.5 ,44. 2 x 3/4 35813020006 1.60 1.60 1.97 10 20 1.6 2 x 1 35R13020010 1.73 1.73 2.02 8 16 1.7 e>1 2 x 1 x 2 35RT3020010020 2.25 2.02 2.25 8 16 1.9 2 x 1-1/4 35R13020012 1.90 1.90 2.10 8 16 - 1.9 2 x 1-1/4 x 2 35RT3020012020 2.25 2.10 2.25 8 16 2.0 2 x 1-1/2 35RT3020014 2.02 2.02 - 2.16 8 16 2.1 2 x 1-1/2 x 1/2 35R13020014004 1.49 1.41 1.88 10 20 1.3 2 x 1-1/2 x 3/4 35RT3020014006 1.60 1.52 1.97 10 20 1.4 2 x 1-1/2 x 1 35RT3020014010 1.73 1.65 2.02 8 16 1.5 2 x 1-1/2 x 1-1/4 35RT3020014012 1.90 1.82 2.10 8 16 1.7 2 x 1-1/2 x 1-1/2 35813020014014 2.02 1.94 2.16 8 16 1.8 Fig. 35BT3-Bull Head Tee Size A B C Packing Weight Part Number IM in in in in Inner Master lb C 3/4 x 1 35B13006010 1.45 1.45 1.37 30 60 0.6 -a���� 1 x 1-1/4 35BT3010012 1.67 1.67 1.58 20 40 0.9 • 1 x 1-1/2 35B13010014 1.80 1.80 1.65 15 30 1.0 e A B 1-1/4 x 1 x 1-1/2 35B-13012010014 1.88 1.80 1.82 15 30 1.2 ill 1-1/4x1-1/2 35813012014 1.88 1.88 1.82 15 30 1.3 1-1/4 x 2 35B13012020 2.10 2.10 1.90 10 20 1.6 1-1/2 x 1-1/4 x 2 35813014012020 2.16 2.10 2.02 10 20 1.8 1.1/2 x 2 35B13014020 2.16 2.16 2.02 8 16 1.8 SMITH-COOPER INTERNATIONAL° • TOLL FREE 1-800-766-0076 • FAX(323)890-4456 • www.smithcooper.com 112 . '. Ductile Iron Fittings - Class 300 UL/FM I • c us APPROVED A Fig. 35CP3 -Straight Coupling with Ribs LISTED '0 1 I Size Part Number A PackingMaster Weight in in lb 1/2 35083004 1.38 200 400 0.1 0.2 3(4 35083006 1.63 Inner 100 200 1 35083010 1.75 60 120 0.4 1-1/4 35083012 2.00 35 70 0.5 1-1/2 35083014 2.19 25 50 0.7 2 35083020 2.62 15 30 1.2 2-1/2 35083024 3.00 9 18 2.2 Fig. 35RC3 -Hex Reducing Coupling p,l �� Size Part Number A Packing Weight in in lb A 1 x 1/2 1 x 3/4 35803010004 1.69 80 160 0.3 35RC3010006 1.69 60 120 0.4 1-1/4 x 3/4 35RC3012006 2-06 40 Inner Master 80 0.6 2 x 1 (not hex) 35RC3020010 2.81 20 40 1.0 Fig. 35HB3 -Hex Bushing Size Part Number A Packing Weight B in in Inner Master lb _ ) 1 x 1/2 35HB3010004 1.06 180 360 0.2 I�I - 1 x 3/4 35HB3010006 1.06 180 360 0.1 i y 1-1/4 x 1 35HB3012010 1.19 90 180 0.2 1-1/2 x 1 35HB3014010 1.25 75 150 0.4 ,:, 1-1/2 x 1-1/4 35HB3014012 1.25 75 150 0.3 2 x 1 35HB3020010 1.38 40 80 0.6 2 x 1-1/4 35HB3020012 1.38 40 80 0.6 2 x 1-1/2 35HB3020014 1.38 40 80 0.6 4 Fig. 35SP3 -Square Head Plug ,. Size Part Number A Packing Weight • in in Inner Master lb 1/2 35SP3004 0.94 600 1200 0.07 3/4 35SP3006 1-12 350 700 0.1 it 1 i A 1 35SP3010 1.25 200 400 0.1 1-1/4 35SP3012 1.37 100 200 0.3 1-1/2 35SP3014 1.44 80 160 0.4 2 35SP3020 1.50 45 90 0.6 Fig. 35U 3- Union with Brass Seat A Size Part Number A Packing Weight gam in in Inner Master lb amediteal1 35U 3010 2.19 20 40 1.0 I1II1-1/4 35U 3012 2.50 15 30 1.2 � 1-1/2 35U 3014 2.62 10 20 1.7 saiteRrigrivird 2 35U 3020 3.12 6 12 2.4 iota11,• 113 SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX(323)890-4456 • www.smithcooper.com * Ductile Iron Fittings- Class 300 UL/FM +51 C 41.0 US 44111:2 fa APPROVED Fig. 35X 3- Cross LISTED A_ A Size A Packing Weight ;; � Part Number tosI in in Inner Master lb lia,,���_ A1 35X 3010 1.50 20 40 0.9 1-1/4 35X3012 1.75 12 24 1.4 , i I�� -A 1-1/2 35X 3014 1.94 8 16 1.8 2 35X 3020 2.25 6 12 2.8 B Fig. 35RX3-Reducing Cross B( '( ' Size A B Packing Weight . 1��' Part Number �• _ i �_ A in in in Inner Master lb 1-1/4 x 1 35RX3012010 1.67 1.58 15 30 1.2 , , 1 � 1-1/2-x 1 35RX3014010 1.80 1.65 12 24 1.4 m 1 2 x 1 35RX3020010 2.02 1.73 8 16 2.0 -- I A Fig. 35C 3- Cap Size Part Number A Packing Weight /® in in Inner Master lb A 1/2 35C 3004 0.87 300 600 0.1 ' 3/4 35C 3006 0.97 200 400" 0.1 1 35C 3010 16 110 220 0.2 1-1/4 35C 3012 1.28 70 140 0.4 III ' 1-1/2 35C 3014 1,33 50 100 0.5 1 4 2 35C 3020 1.45 25 50 0.8 2-1/2 35C 3024 1.70 18 36 1.6 ` 1 Fig. 35BC3-Beam Clamp - Ili Size A Packing Weight Part Number _ Al in in Inner Master lb - P3/8 35BC3003 0.75 100 200 03 1/2 35BC3004 0.75 80 160 0.5 1 • SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX(323)890-4456 • wwwsmithcooper.com 114 • Z§ P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626A44.3887 www. Afcon.org 510 CPVC - COPPER - STEEL HANGER �.... 510 Fastener Dim. 46SIZE �.'4- � 0 3/4 2.125 1 2.312 1 1/4 3.170 Q 1 1/2 3.400 2 4.010 2 1/2 4.320 ® 3 5.320 SIZE-SYSTEM PIPE:3/4"thru 3" MATERIAL-Carbon Steel. III FINISH-Mil.Galvanized. LISTING/APPROVAL- `®"203-EX 4231,EX 2551 WM FUNCTION-Support horizontal piping:3/4"-3" CPVC. Support horizontal piping:3/4"-2"Steel and Copper. Size 3/4"-2"provides listed vertical/lateral restraint and prevents upward movement of pipe that supplies a pendent sprinkler below a ceiling. Stabilize vertical piping. ii Hanger INSTALLATION- Per these instructions 1PBIIIIIIIIMIIIS including NFPA 13, 13R, 13D and CPVC manufacturers instructions. Fl Install on horizontal or vertical mounting surface. FASTENERS- UL Listed per NFPA 13 in WOOD: 3/4"-3"CPVC pipe-#905 screw-no pre-drill. COMIC C Stabilize-Only 3/4"-2" Steel and Copper pipe- 1/4"x11/2"lag bolt-no pre-drill. II in STEEL-min. 18 GA. 1W- 3/4"-3"CPVC pipe- 1/4"or#14 Tek Screw. 3/4"-2" Steel and Copper pipe- 1/4"or#14 Tek Screw. 4... FEATURES *Offset edge eliminates abrasion. *Retainer dimples secure hanger to pipe during installation. *Required AFCON#905 screw included-5/16"hex head. ORDERING-Part#and pipe size. CAN ALSO BE USED TO REPLACE -#500 Pipe Strap ': #520 Tin Strap III Specific AFCON products are exclusively designed to be compatible ONLY with other AFCON products including parts and fasteners,resulting in a listed sway brace,restrainer or hanger assembly. Be advised the following warranty restriction will apply.DISCLAIMER-AFCON will NOT warrant against the failure of its products when used in combination with other products,parts or systems not manufactured or sold by AFCON.AFCON shall NOT be liable under any circumstances whatsoever for any direct or indirect,incidental or consequential damages of any kind,including but not limited to loss of business or profit,when non-AFCON products have been,or are used. 1/12 v • P.O. Box 3365 South El Monte, CA 91733 626A44.0541 Fax 626.444.3887 www. Afcon.org 511 CPVC - COPPER SIDE MOUNT HANGER • o I: 0 Side View-For Drawings Below • O O SIZE-SYSTEM PIPE: 3/4"thru 2" MATERIAL-Carbon Steel. l�,t' FINISH-Mil.Galvanized. LISTING/APPROVAL- `®"203-EX 4231,EX 2551 FUNCTION- Support horizontal piping-CPVC or Copper. Stabilize vertical piping. INSTALLATION-Per these instructions Hanger-Wood Stud -_ including NFPA 13, 13R,13D_and CPVC manufacturers instructions. Install on vertical mounting surface. FASTENERS-UL Listed per NFPA 13. in WOOD: 3/4"-2"CPVC pipe-#905 screw- no pre-drill. 3/4"-2"Copper pipe-#905 screw- no pre-drill. in STEEL-min. 18 GA. 3/4"-2"CPVC pipe- 1/4"or#14 Tek Screw. 3/4"-2"Copper pipe- 1/4"or#14 Tek Screw. FEATURES *Offset edge eliminates abrasion. *Retainer dimples secure hanger to pipe during installation. *Required AFCON#905 screw included-5/16"hex head. ORDERING-Part#and pipe size. Hanger-Metal Stud Specific AFCON products are exclusively designed to be compatible ONLY with other AFCON products including parts and fasteners,resulting in a listed sway brace,restrainer or hanger assembly. • Be advised the following warranty restriction will apply.DISCLAIMER-AFCON will NOT warrant against the failure of its products when used in combination with other products,parts or systems not manufactured or sold by AFCON.AFCON shall NOT be liable under any circumstances whatsoever for any direct or indirect,incidental or consequential damages of any kind.including but not limited to toss of business or profit,when non-A FCON products have been,or are used. 9/08 P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 513 CPVC - STEEL - COPPER HANGER a \4(41%'-- • SIZE-SYSTEM PIPE: 3/4"thru 2"pipe. Hanger MATERIAL-Carbon Steel. .1111-S FINISH-Mil.Galvanized. LISTING/APPROVAL- ®as 203-EX 4231,EX 2551 NE Stabilize-Only FUNCTION-Support horizontal piping- CPVC,Copper or Steel. Tab up=Hanger. Stabilize vertical piping. INSTALLATION- Per these instructions including NFPA 13, 13R and 13D on and CPVC manufacturers instructions. Install on vertical mounting surface. FASTENERS-UL Listed per NFPA 13. in WOOD: 3/4"-2"CPVC pipe-#905 screw-no pre-drill. 3/4"-2"Copper pipe-#905 screw-no pre-drill. 3/4"-2"Steel pipe- 1/4t"xl 1/2"lag screw-no pre-drill. FEATURES *Offset edge eliminates abrasion. *Required AFCON#905 screw included-5/16"hex head. ORDERING-Part#and pipe size. • Specific AFCON products are exclusively designed to be compatible ONLY with other AFCON products including parts and fasteners,resulting in a listed sway brace,restrainer or hanger assembly. Be advised the following warranty restriction will apply.DISCLAIMER-AFCON will NOT warrant against the failure of its products when used in combination with other products,parts or systems not manufactured or sold by AFCON.AFCON shall NOT be liable under any circumstances whatsoever for any direct or indirect,incidental or consequential damages of any kind,including but not limited to loss of business or profit,when non-AFCON products have been,or are used. ¢ y 001 3/08 g P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org • 514 CPVC — COPPER #905 #906 • STEEL -,„ —i OFFSET HANGER 1n 3.00 I 4,1 Y SIZE-SYSTEM PIPE: 3/4"thru 3" O" MATERIAL-Carbon Steel. FINISH-Mil.Galvanized.. LISTING/APPROVAL- CON 203-EX 4231,EX 2551 PATENT-No.6,648,278. ') I•, FUNCTION- Support horizontali in :3/4"-3" CPVC or Copper.pp g pp • • Support horizontal piping:3/4"-2"Steel. Size 3/4"-2"provides listed vertical/lateral restraint and prevents upward movement 111) of pipe that supplies a pendent sprinkler below a ceiling. Stabilize vertical piping. INSTALLATION INSTALLATION- Per these instructions including NFPA 13, 13R, 13D and CPVC manufacturers instructions. Listed Restraint Install on horizontal or vertical mounting surface. 3�4°ihru 2° =_ Snap over pipe then squeeze strap back allowing pipe to slide freely. a— —� -- When #905 threads are exposed in wood,install#906 backing nut. kITO FASTENERS-UL Listed per NFPA 13 WOOD- 3/4"-3"CPVC pipe-#905 screw-no pre-drill. 3/4"-2"Copper pipe- #905 screw- no pre-drill. 3/4"-2"Steel pipe- 1/4"xl 1/2"lag screw- no pre-drill. Thru 5/8"gypsum board-1/4"x 2"lag screw. STEEL-min. 18 GA.- 3/4"-3"CPVC pipe- 1/4"or#14 Tek Screw. 4 • 3/4"-2"Copper pipe- 1/4"or#14 Tek Screw. 3/4"-2" Steel pipe- 1/4"or#14 Tek Screw. CONCRETE: Required minimum load each fastener= 5(wt)+2501bs. 2 FEATURES * I 1/2"Offset-loose fit allows pipe to slide. LissdRe mint *3/4"and 1"pipe size made with common center-line. 3/4"thru 2" *Patented design for superior strength. *Offset edge eliminates abrasion. *AFCON#905 screw included-5/16"hex head. ORDERING-Part#and pipe size. AFCON#906 backing nut sold separately. Specific AFCONproducts are exclusively designed to be compatible ONLY with other AFCON products including parts and fasteners,resulting in a listed sway brace,restrainer or hanger assembly. • Be advised the following warranty restriction will apply.DISCLAIMER-AFCON will NOT warrant against the failure of its products when used in combination with other products,parts or systems not manufactured or sold by AFCON.AFCON shall NOT be liable under any circumstances whatsoever for any direct or indirect,incidental or consequential damages of any kind,including but not limited to loss of business or profit,when non-AFCON products have been,or are used. a 'Yk rT 10/08 .._,; 40 42 P.O. Box 3365 South EI Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 515 CPVC DOUBLE OFFSET HANGER T1/oa 4111 SIZE-SYSTEM PIPE:3/4"and 1" MATERIAL-Carbon Steel. FINISH-Mil.Galvanized. LISTING/APPROVAL- c®.203-EX 4231 PATENT-No.6,702,236 FUNCTION-Support/Restrain horizontal CPVC piping. / INSTALLATION- Per these instructions ' including NPFA 13, 13R, 13D and CPVC manufacturers instructions. Install on horizontal or vertical mounting surface. FASTENERS-UL Listed per NFPA 13. WOOD: 3/4"and 1"#904 screw- no pre-drill. 0 FEATURES *Double 1 1/2"offset *Center line matches AFCON#514. *3/4"and 1"pipe size have common center-line. *Offset edge eliminates abrasion. *Required AFCON#904 screw included-3/8"hex head. ORDERING-Part#and pipe size. 1110 Specific AFCON products are exclusively designed to be compatible ONLY with other AFCON products including parts and fasteners,resulting in a listed sway brace,restrainer or hanger assembly. Be advised the following warranty restriction will apply.DISCLAIMER-AFCON will NOT warrant against the failure of its products when used in combination with other products,parts or systems not manufactured or sold by AFCON.AFCON shall NOT be liable under any circumstances whatsoever for any direct or indirect,incidental or consequential damages of any kind,including hut not limited to loss of business or profit,when non-AFCON products have been,or are used. 3/08 P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org • 519 CPUC ADJUSTABLE HANGER Jr 1//i i/ iki?)0 /% _I •e //I 14 Canopy I.D._ � A 21/4"min. 1 El /e , SIZE-SPRINKLER THREADS: 1/2"and 3/4"npt. MATERIAL-Carbon Steel. FINISH-Plain. LISTING/APPROVAL- a 1.6636—0•• `®us 203-EX 4231 — E■ PATENT-No.6,755,379,No.6,783,102,No.7,017,868 FUNCTION-Support/restrain CPVC piping at the sprinkler head. Provide vertical adjustment. INSTALLATION- Per these instructions including NPFA 13, 13R, 13D and CPVC manufacturers instructions. 1.7000 Install on vertical mounting surface. ASSEMBLY-See drawing. _ Combine with appropriate sprinkler canopy I Insert correct sprinkler head through#519 bore,then 4 —0-1 1.0757 thread into CPVC adapter. *Verify assembled product prior-may not fit some product combinations-see note. *Note-some canopies won't accommodate the#519 FASTENERS-UL Listed per NFPA 13. in WOOD:#904 screws- nore-drill. #519 uses the standard thread gap between the sprinkler head and the 1� sprinkler fitting as a point of mounting attachment. This is the only available FEATURES uniform point of attachment not detrimental to the CPVC piping. * 1"adjustment usingdriver. a screw Beware-some canopy designs conflict with the installation of the#519. * 1 1/2"offset matches AFCON#514 and#515. Do not install the#519 when canopies have conflicting geometry or *Required AFCON#904 screw included-3/8"hex head. dimensions. Examples are: ORDERING-Part#and size. • Flared canopy hole may conflict with standard thread gap • Required canopy I.D.=2 1/4"min. Specific AFCON products are exclusively designed to be compatible ONLY with other AFCON products including parts and fasteners,resulting m a listed sway brace,restrainer or hanger assembly. • Be advised the following warranty restriction will apply.DLSCLAIMER-AFCON will NOT warrant against the failure of its products when used in combination with other products.parts or systems not manufactured or sold by AFCON.AFCON shall NOT be liable under any circumstances whatsoever for any direct or indirect,incidental or consequential damages of any kind,including hut not limited to loss of business or profit,when non-AFCON products have been,or are used. 4/08 0 ,401/ P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 300 RING HANGER NFT1::75o UL 1 TESPIPE ROD LOA/ i 5 750 / � 11/4 3I8 43.95 469.75 750 ` / 11/2 3/8 54.15 520.75 750 �/ / 2 3/8 76.95 634.75 750 21/2 3/8 118.35 841.75 650 • 3 3/8 162.30 1061.50 1050 1 thru 4 inch pipe 1/2&3/4 inch pipe 4 3/8 246.00 1480.00 1500 LISTED FOR STEEL/CPVC 5 thru 8 inch pipe 5 1/2 349.45 1996.75 2000 6 1/2 476.35 2631.75 2650 8 1/2 711.00 3805.00 4050 SIZE-ROD-3/8"or 1/2" SIZE-SYSTEM PIPE-1/2"thru 8" MATERIAL-Carbon Steel. FINISH-Mil.Galvanized to G-90 specification. LISTING/APPROVAL- `, Eo05 203-EX 2551 I"-8" 0 Approval guide-1"-8" OSHPD OPA-0601 See Website. Conforms to Federal Specification WW-H-171E type 10,and Manufacturers Standardization Society SP-69,type 10. MAXIMUM TEMPERATURE-650°F. FUNCTION-Pipe component of an AFCON hanger. To support horizontal steel,CPVC or copper pipe. INSTALLATION-Per these instructions including NFPA 13 and the CPVC manufacturers instructions. PIPE A B FEATURES 1 '.8793 2.5250 1114 2.1382 2.7850 *Sized and listed exclusively for use with#310 Surge Restrainer. ' r ' 1 112 22673 2914 *Band edge is offset for EASY pipe insertion. B 2 2.6945 3.2516 * Custom fit swivel nut for better retention in ring. A 212 2.7500 35050 ORDERING-Part#,pipe size. �'�.1 3 30625 38205 r 4 35625 4.3205 • is 5 4.0940 4.9397 6 4.6250 5.4707 8 7.5620 6.4077 a , 9/15 :. Pipe Hangers Fig. 2 - Adjustable Band Hanger (B-Line B3170) c uL us .® Fig. 2F - Adjustable Band Hanger Felt Lined for Copper Tubing (B-Line B3170F) LISTED • Size Range: ®TOLCD Fig. 2 - 21/2"(65mm)thru 6"(150mm)pipe As Fig. 2F - 21/2"(65mm)thru 6"(150mm)pipe Material: Pre-Galvanized Steel C a , I /- ' 011, Function: Recommended for the suspension of non- insulated pipe or insulated pipe with B3151 shield. { o Fig. 2NFPA accomodates the reduced rod schedule of �' ,( the National Fire Pretection Association Pamphlet 13. �. Approvals: Factory Mutual Engineering Approved. Underwriters Laboratories Listed. Conforms to Federal Specification WW-H-171E&A-A-1192A Type 10 and Fig 2 Manufacturers Standardization Society ANSI/MSS SP-69&SP-58,Type 10. Standard Finish: Pre-Galvanized Note: Available in Stainless Steel material. Order By: Part number and finish. (4111 c B li\ le, \At ' eC D Fig.2 Fig.2F Nominal Pipe Size Rod Size B C D Max.Rec.Load Approx Wt./100 • v Part No. in. (mm) A in. (mm) in. (mm) in. (mm) lbs. (kN) lbs. (kg) n m = 2-21/2 21/2" (65) 1/2"-13* 53/4" (146.0) 41/4" (107.9) 15/8" (41.3) 600 (2.67) 41 (18.6) ca 2-3 3" (75) 1/2"-13* 6" (152.4) 41/8" (104.8) 11/4" (31.7) 600 (2.67) 45 (20.4) 2-3112 31/2" (90) 1/2"-13* 73/8" (187.3) 51/4" (133.3) 21/8" (54.0) 600 (2.67) 52 (23.6) co 2-4 4" (100) 5/8"-11 * 73/a" (187.3) 5" (127.0) 15/8" (41.3) 1000 (4.45) 59 (27.6) 2-5 5" (125) 5/8"-11 ** 9" (228.6) 61/8" i (155.6) 21/4" (57.1) 1250 (5.56) 97 (44.0) 2-6 6" (150) 3/4"-10** 93/8" (238.1) 61/2" (165.1) 17/8" (47.6) 1250 (5.56) 139 (63.0) Fig.2F Nominal Pipe Size Rod Size B C 0 Max.Rec.Load Approx Wt./100 Part No. in. (mm) A in. (mm) in. (mm) in. (mm) lbs. (kN) lbs. (kg) 2F-21/2 21/2" (65) 1/2"-13* 53/4" (146.0) 41/4" (107.9) 15/8" (41.3) 600 (2.67) 41 (18.6) 2F-3 3" (75) 1/2"-13* 6" (152.4) 41/8" (104.8) 11/4" (31.7) 600 (2.67) 45 (20.4) 2F-31/2 31/2 (90) 1/2"-13* 73/8" (187.3) 51/4" (133.3) 21/8' (54.0) 600 (2.67) 52 (23.6) 2F-4 4" (100) 5/8"-11 * 73/8" (187.3) 5" (127.0) 15/8" (41.3) 1000 (4.45) 59 (27.6) 2F-5 5" (125) 5/8"-11 ** 9" (228.6) 61/8" (155.6) 21/4" (57.1) 1250 (5.56) 97 (44.0) 2F-6 6" (150) 3/4"-10** 93/8" (238.1) 61/2' 1 (165.1) 17/8" (47.6) 1250 (5.56) 139 (63.0) "/8 nut is used when requested. **1/2 nut is used when requested. • At dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. B-Line by 1 .a" . 59 Pipe Hangers&Supports Threaded Accessories Fig. B3205 - Threaded Rod (right-hand threads - both ends) (TOLco Fig.103) TOL'CO • Fig. B3205L - Threaded Rod (right& left hand threads) TL Size Range: 3/8"-16 thru 3"-4 rod Specify Length Material: Steel Function: Recommended for use as a hanger support in hanger assemblies. Rod is threaded on both ends with right hand threads of the length shown.Also TL 11 available with left and right hand threads-specify Fig. B3205L when ordering. 1�1� �11�llll A Maximum Temperature: 750°F(399°C) Thread Size Finish: Plain. Contact Cooper B-Line for alternative finishes and materials. Order By: Figure number, rod size,length and finish Standard Design Load Thread Size Thread Length TL 650°F(343°C) 750°F(399°C) Part No. A in. (mm) Lbs. (kN) Lbs. (kN) B3205-3/a x'L' 3/8"-16 21/2" (63.5) 730 1 (3.25) 572 1 (2.54) B3205-112 x'L' 1/2"-13 21/2" (63.5) 1350 (6.00) 1057 (4.70) B3205-5/8 x'L' 5/8"-11 21/2" (63.5) 2160 (9.61) 1692 1 (7.52) B3205-3/4 x'L' 3/4"-10 3" (76.2) 3230 (14.37) 2530 (11.25) 133205-7/8 x'L' 7/8"-9 31/2" (88.9) 4480 (19.93) 3508 (15.60) • For larger sizes consult full line pipe hanger catalog. Fig. ATR - All Threaded Rod (TOLCO Fig.99&Fig.100) - ��', , Size Range: 3/8"-16 thru 11/2"-6 rod in 10'(3.05m)lengths \• , Material: Steel ��\��� Maximum Temperature: 750°F(399°C) X11 Finish: Plain.Contact Cooper B-Line for alternative finishes and materials. �10 IS� 111 Order By: Figure number, rod size, length and finish �� 111 Note: Fig.99 is cut to length all threaded rod. Fig. 100 is full length. --JJ Part No. Threads Recommended Load Approx.Wt./100 Ft. , &Size Per Inch Lbs. (kN) Lbs. (kg) ATR 1/4"X`L' 20 240 (1.07) 12 (5.44) , a =- ATR 3/8"x'l' 16 730 (3.24) 29 (13.15) ` ° ATR 1/2"X'L' 13 1350 (6.00) 53 (24.04) ATR 5/8"x't.' 11 2160 (9.60) 89 (40.37) ATR 3/4"x`L' 10 3230 (14.37) 123 (55.79) ATR 7/a"x`L' 9 4480 (19.93) 170 (77.11) illFor larger sizes consult full line pipe hanger catalog. All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. IIIIIIIIIIIIIIIIIIIIIIIIIIIIEIIIIIIIIIIIIIIIIIIIPrMiaMioo COOPER B-Line � s ,47.,,,,,., . ..,.,. Alk/TAildexs . �la0 ex ,,,,,....„,,,„,,,„:4,,,,,,, ::.:,,,,,,,„„;„, .f I,4,,,,,t, SAMMY6 .F„:,,„.,,,, ,.:„...,...--,:ifi;i5e,f;:44,,,,,:1, 2012 PRODUCT CATALOG www.itwbuildex.com 800-BUILDEX ° � , ,, ,,,,,,i- -,ti:i.- ;,,.--c-... ..wrip 4111.4wAin,w— 41, Y k 5 ll ....4.f k. , S Y a„ tit) I SAMMYS® FOR WOOD 111! SAMMYS' FOR WOOD - Vertical Application, Application , C 1 Not less than 2"nominal width (1-1/2") 4----, Not less than 3"nominal thickness(2-112') Wood Flooring , ,g• . . .,, ' ' — . (depth or side Wood Joist „,,, Product Features •No pre-drilling required. of vertical member) •Quick to install using the Sammy Nut Driver with an 18V cordless drill/driver. thic •Saves time from traditional ,.1 ' methods. 7,41 ' 'V Double Sheetrock t ' 1 f' Ceiling 11 •Reduces installation costs. II .3010 311 ":.,,, •Manufactured in the U.S.A. ..„ ., rillenal for NFPA 13,ompli.ani-i= 40), _.'i!,. ,Composite I Truss 1 ,.. watch'itWetin uildex.cOnai) Approvals Rod Part Screw Ultimate UL Test FM Test Box Case Model Size Number DescrioClons Pul;out.lbs; Load(lbs) Load,lbs) Qty Q!,, VERTICAL MOUNT Aftwilir5ro:...,,,,,,,,,vm:60vott 1/4" 8002957 GST 100 1/4 x 1” 210(7/16'OSB) 25 125 670 (3/4"Ply) ,,..:::11"ffrA.4:11IIII;,- 1/4" 8003957 GST 200 1/4 x 2".",.44,0 1760(Fir) :-.1.1,,:f4k- ,J.,..,,: s-,,,,it'),,,,", 25 125 ' ., 11 3/8 8007957 GST 10 1/4 x 1" 210 (7/16"OSB) 670(3/4"Ply) 300 25 125 ifn:.':::,.' 41 3/8" 8008957 GST 20 1/4 x?77" 1760 (Fir) .4,1115.17,I;850 EI, 1475 25 125 Q., 3/8" 8068925 GST 20-SS 1/4 x 2" 1760 (Fir) 850 25 125 #14 Black 3/8'3/8" 8009925 GST 25-380 3/8 x 2-1/2" lri. 2113(Fir) ittIl::-1 1500 Irr I 25 125 Nut Driver 451,41?::" 3/8" 8010957 GST 30 1/4 x 3" 2060 (Fir) 1500 1475 25 125 Part#8113910 , --, ..„.,,,, 3/8" 8069925 GST 30-SS 1/4 x 3" :4,„44,I,I 2060(Fir) ;I.ii'14„:4IiI Il. 25 125 1/2" 8013925 GST 2 1/4 x T .,. 1760 (Fir) II.,":-• 25 125 112" 8015925 GST 3 1/4 x 3--,1!"--7.444. 2275 (Fir) :1 25 125 #14 SW Red Nut Driver Peril 8114910 ....— ' (--- (77 M VeeeJFecnJREo 5.5A riii"''IS) SPECIAL NUT DRIVER SYSTEM:The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time.When the face of the driver comes into contact with the material you are installing into,continue drilling until nut driver spins free.Installation is then complete.Warranty requires the use of the appropriate nut driver for installations. For the most up to date information,visit www.itwsundex.com 4 1 AlltIgNgTi, 1.--. SIDEWINDER® FOR WOOD -Horizontal Application Application Product Features Not less than 2"nominal width •No pre-drilling required. (1-1/2")up to 3-1/2"pipe;not less than 3"(2-112*)nominal width 4'&5°pipe )4 •Quick to install using the Sammy "" 4--� Floor Joist Nut Driver with an 18V cordless s drill/driver. 1 Minimum 2-1/2"from bottom for �„ ' ' r, branch lines.Minimum 3"from bot- g 4 491 r'ti' tom for main lines.Exception:This •Saves time from traditional r> requirement shall not apply to 2°or methods. thicker nailing strips resting on top of steel beams. ''>:), •Reduces installation costs. Is A `�; •Manufactured in the U.S.A. F r Composi•te I firuss t.r fi , � Ganeuf•,r i aluf. r ra° C s. Mp r,R atx r-r :; ' '' . ' P e oit-ng^,a}te re1it d ;i Watch a vMeo demonstration ai"+t aJ www rtwbutldex.com, 1�� Screw Ultimate UL Test Box Case w`� Cl) 141 Model A /w pprr oval` Rod Part Size Number Descriptions Pullout(lbs) Load(lbs) Qty Qty + HORIZONTAL MOUNT e0 7I.i 1/4" 8019957 SWG 200 " 1!4 x 2" 1725 (Fir) 25 125 318 „`8020957 SWG 10 114 x 1” 622(Fir) 300 25 125 1 i. 318" 8021957 SWG 20 114 x 2" 1725 (Fir) 1050 25 125 318 ;18073925 SWG 20 SS 114 x 2" 1725(Fir) 850 25 25 12 ": 3/8 8022925 SWG 25-380 3/8 x 2-1/2" 2249(Fir) 1500 125 #14 SW Red 3/6" = 8023925 SWG 30 1/4 x 3" 1884 (Fir) 25 125 41 ft Nut Driver W Part#8114910 *May require pre-dolling;consult joist manufacturer. Ct SAMMYS SWIVEL HEADTM FOR WOOD - Swivel Application ti Z Application Product Features V lctr. regArTIOS •Eliminates distortion of threaded rod. m447 •Accommodates up to 314"x 12 pitch roof. ,; - •Allows 17'deflection from vertical. ¢ y """A°' •Saves-time-from traditional methods. i, W •Reduces installation costs. } 't Manufactured in the U.S.A. 0 ''''' ! Waw: , , w Cl) Approvals Rod Part Model Screw Ultimate UL Test Load FM Test Min Box Ca,, W Size Number Descriptions Pullout(lbs) (lbs) Load(lbs) Thickness Qty Qty V SWWU8L.•:' rt � ,,nY)k ,' 4 ,u#t v, '' #14 Black . U Nut Driver —E 3/8" 8139957 SH-GST 20 1/4 x 2" 1257(Fir) 1050 1475 25 125 Q Part#8113910 S1903 Dim.Lumber 1500 `* 3/8"" 8269957 SH-GST/CST 20 5/16 x 1-314" 1406 @ 45°off vertical 850 @ 45° 25 125 Dim.Lumber �/w� 903 Dim.Lumber `I) 1/2" 8303957 SH-GST/CST 2.0 5/16 x 1-3/4" 1406 @ 45°off vertical 25 125 J Dim.Lumber Q *May require predrilling;consult joist manufacturer. #14 SH Orange Nut Driver O. a a 5To find a distributor near you,call 800-BUILDEX APPROVAL C Pmt3 �t 111 Part Model Rod Size Mount UL Max UL Test UL Min Wood FM Max FM Test FMMln Wood Number Direction Pipe Size Load(lbs) Thickness Pipe Size Load(lbs) Thickness '.SPAM FOR WO b E HANG t" 1$a xj G; . ,; 8007957 GST 10 3/8° Vertical CPVC 1-1/2" 300 1-1/2" 8020957 SWG 10 3/8" 8008957 GST20 3/8" 8068925 GST20-SS 3/8" 8010957 GST 30 3/8" 8009925 GST 25-380 3/8" Horizontal CPVC 1-1/2" 300 1-1/2" Vertical 2-1/2" 850 1-1/2" 4" 1475 1-1/2" Vertical 2-1/2" 850 1-1/2" Vertical 4" 1500 1-1/2" 4" 1475 1-1/2" Vertical 4" 1500 1-1/2" 8022925 SWG25-380 3/8" Horizontal 3-1/2"-4* 1500 1-1/2" 8021957 SWG 20 3/8" Horizontal 2-1/2"-3""" 1050 1-1/2" 8073925 SWG 20-SS 3/8" Horizontal 2-1/2" 850 1-1/2" 8269957 SH-GST/CST 20 3/8" 45°Angle off Vertical 2-1/2" 850 1-1/2" 8269957 SH-GST/CST 20 3/8" 45°Angle off Vertical 4" 1500 1-1/2" 8139957 SH-GST 20 3/8" 17°Angle off Vertical 3" 1050 1-1/2" 4" 1475 1-1/2" 8038957 DSTR 1 3/8" Vertical 4" 1500 .035" 4" 1475 .105" 8037957 DSTR 1-1/2 318" Vertical 4" 1500 .035" 4" 1475 .105" 8039957 DSTR 516 3/8" Vertical 4" 1500 .037" 4" 1475 .105" 8045957 DST 516 3/8" Vertical 4" 1500 .188" 4" 1475 .188" 8046957 TEK 50 3/8" Vertical 4" 1500 .250" 4" 1475 .188" 8055957 SWDR 1 3/8" Horizontal 4" 1500 .037" 4" 1475 .060" 8056957 SWDR 516 3/8" Horizontal 4" 1500 .037" 4" 1475 .060" 8054957 SWDR 1-1/2 3/8" Horizontal 4" 1500 .037" 4" 1475 .060" 8137957 SH-DSTR 1 3/8" 17°Angle off Vertical 4" 1500 .035° 4" 1475 .105" 8268957 SH-TEK 50 3/8" Vertical 2-1/2" 850 70°Angle off Vertical 4" 1500 8150922 XP 20 3/8° Vertical 2-1/2" 850 .027" 2" 940 029 4" 1475 .105" 8153922 XP 35 3/8" Vertical 4" 1500 .060" 2" 940 .029" 4" 1475 .125" 8294922 SXP 20 3/8" Vertical or up to 45° 2" 750 .027" 2" 635 .029" 8295922 SXP 35 3/8" Vertical or up to 89° 3-1/2" 1250 .060" 2" 635 .029" 8293957 SWXP 35 3/8" Horizontal 3-1/2" 1250 .060" 'SAINTS FOR CONCRETE-PIPE HANGER - 8059957 CST 20 3/8" Vertical 4' 1475 3000 8061957 SWC 20 3/8" Horizontal 4" 1475 3000 8150922 XP 20 3/8" Vertical 2-1/2" 850 Pre-Pour Structural @ 3000psi 8150922 XP 20 3/8" Vertical 2-1/2" 850 Post-Pour Range II LWC<35 PCF(Ibs/ft3) Part Model Rod Mount UL Load UL Min Steel Number Size Direction Rating(lbs) Thickness . E FITTING' 8150922 XP 20 318" Vertical 185 027x' 250 .035" 8153922 XP 35 3/8" Vertical 185 .027" 250 .035" 8181922 XP 200 114" Vertical 185 027° 250 .035" 8294922 SXP 20 3/8" Vertical 170 .027" 45° 80 .027" 8295922 SXP 35 3/8' Vertical 250 060" 90 80 .060° 8293957 S'v11XP 35 3/8" Horizontal 80 .060" PartModel Rod Mount UL Load UL Min.Steel Listed Application Number Size Direction Rating(lbs) Thickness 8150922 XP 20 3B" Vertical 283 .027" Max 4 trade size EMT,RMC,and IMC&5 trade size rigid PVC conduit 8153922 XP 35 318" Vertical 500 .060" Max 4 trade size EMT&6 trade sze RMC,IMC,and rigid PVC conduit 8294922 SXP 20 3/8' Vertical 283 .027" Max 4 trade size EMT,RMC,and IMC&5 trade size rigid PVC conduit 8295922 SXP 35 3/8' Vertical 500 .060" Max 4 trade size EMT&6 trade sze RMC,IMC,and rigid PVC conduit 8293957 SWXP 35 3/8" Horizontal 500 .060" Max 4 trade size EMT&6 trade sze RMC,IMC,and rigid PVC conduit 8149957 CZ2000 1/4"or 318° Onto Vertical Rod UL Listed 4516-Cable Hanger,Cat.No.C-22000 Plenum Rated, Complies w/NEC Standards Sheet Steel Gauges Gauge No. 22 ga. 20 ga. 18 ga. 16 ga. 14 ga. 12 ga. 118" 3/16" 1/4" Nominal Decimal Equivalent .030" .036" .048" .060" .075" .105" .125° .188" .250" 'SWG 25-380 Maximum pipe size in composite wood joist allowed by UL is 3-1/2" UL compliance with NEC Standards. `SWG 25-380 Maximum pipe size in wood timber or joist allowed by UL is 4" UL and FM tests were performed in compliance with NFPA 13 Standards. "SWG 20 Maximum pipe size in composite wood joist allowed by UL is 2-1/2" Fastening requirement:5 times weight of water-filled schedule 40 pipe plus 250 pounds. "SWG 20 Maximum.i.-size in wood timber or hist allowed b UL is 3" For the most up to date information,visitwww.itwbuildex.com 14 o DDD . .vr DDDDD • P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 411 SWAY BRACE FITTING Part#077—_, L ..1, 't Aji ,s w; 4:'m 4,1-1/ oe, „ ,,..„. .,,„,,,,,, •iiit.,, (,e {� SIZE-SYSTEM PIPE:Nominal Pipe Size Sch.40 Steel 1"- 12" Sch. 10 Steel 1 1/4"- 12" III Sch.7 Steel 2"-6" .®e Max.Horizontal Load MATERIAL-Carbon Steel or S.S.(Type 304) 1"-4° 1200 FINISH-Plain or E.G. 5"-10 2765 12" 3740 PATENT-No.7,140,579 LISTING/APPROVAL egos 203A-EX 2625 ® FM Approved-1950 ism FUNCTION-Longitudinal fitting of an AFCON sway brace assembly. ®Max.ASD Horizontal Load INSTALLATION- Per these instructions System Sch. 30°-44° 45°-59° so°-7a° 75°-so° LAPS including NFPA 13 or FM 2-8 1"-1 1/2" 10-40 1070 420 510 570 Load ratingsee chart. 2" LW-40 1570 1900 1730 1930 ' 2 1/2"-4" LW 1000 860 1030 1150 ASSEMBLY-See drawing 4"-5" '10-40 1000 950 1150 1280 Combine with proper AFCON components-see disclaimer below. 6" LW-40 1620 2220 2720 3040 8" 10-ao 2070 1250 1510 1690 Align brace member parallel to face of 411 fastener flanges. Tighten 1/2"bolts until fastener flanges connect. FEATURES * Patented-design eliminates bending of fastener flanges during installation. * Patented-design prevents over tightening on system pipe. * Improved assembly-fastener flanges connect for superior strength. * Visual inspection-proper installation when 411 fastener flanges contact. ORDERING-Part#,size-system pipe and finish. Specific AFCON products are exclusively designed to be compatible ONLY with other AFCON products including parts and fasteners,resulting in a listed sway brace,restrainer or hanger assembly. . Be advised the following warranty restriction will apply.DISCLAIMER-AFCON will NOT warrant against the failure of its products when used in combination with other products,parts or systems not manufactured or sold by AFCON.AFCON shall NOT be liable under any circumstances whatsoever for any direct or indirect,incidental or consequential damages of any kind,including but not limited to loss of business or profit,when non-A FCON products have been,or are used. l4 s a s„ i 4 .': 2/16 O P.O. Box 3365 South El Monte, CA 91733 626A44.0541 Fax 626.444.3887 www. Afcon.org 001/020 SWAY BRACE FITTING MODEL E Part#077 (trAit I .4 ) 1"min. • SIZE-SYSTEM PIPE: Nominal Steel 1"thru 4" Sch. 10 and Sch.40 © Max.Asn Horizontal Load SIZE-BRACE PIPE: 1"or 1 1/4" Sch.40 SNPS Sch. 30°-44° 45°-59° 60°-74°75°-90° MATERIAL-Carbon Steel or S.S.(Type 304). 1" 40 430 610 750 840 FINISH-Plain or E.G. 1 1/4"-1 1/2" LW-40 90 130 160 180 LISTING/APPROVAL- 2" LW 190 280 340 380 10 550 790 960 1080 40 500 710 870 970 FM FM Approved-1950. 2 1/2"-4" I W 160 230 280 320 OSHPD See Website. 2 1/2°-a° 10 260 370 460 510 40 1030 1460 1790 1990 FUNCTION- Lateral fitting of an AFCON sway brace assembly. INSTALLATION-Per these instructions including NFPA 13 and FM 2-8. Load rating-see chart. ASSEMBLY-See drawing. Combine with proper AFCON components-see disclaimer below. Insert brace pipe through rod bend and under channel bracket to achieve minimum 1"extension. Tighten hex nuts until gage spring lays flat or torque to 165 lb-in. FEATURES *Visual inspection,verifies proper installation. ORDERING-Part#,size-system pipe,size-brace pipe and finish. 4110 Specific AFCON products are exclusively designed to be compatible ONLY with other AFCON products including parts and fasteners,resulting in a listed sway brace,restrainer or hanger assembly. Be advised the following warranty restriction will apply.DISCLAIMER-AFCON will NOT warrant against the failure of its products when used in combination with other products,parts or systems not manufactured or sold by AFCON.AFCON shall NOT be liable under any circumstances whatsoever for any direct or indirect,incidental or consequential damages of any kind,including but not 'invited to loss of business or profit,when non-AFCON products have been,or are used. 8/14 0� P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org • 077 ATTACHMENT FITTING LOCKING 17/32" *r_N A 077S STEEL BASE PLATE SIZE-BRACE PIPE: 1" and 1 1/4" Sch.40 MATERIAL-Carbon Steel or S.S.(Type 304). FINISH-Plain or E.G. LISTING/APPROVAL- c®ns 203A-EX2625 0 FM Approved-1950 OSHPD See Website. imTEB FUNCTION-Structure attachment fitting of an AFCON sway brace assembly. INSTALLATION-Per these instructions including NFPA 13 or FM 2-8. Load rating-see chart. ASSEMBLY Combine with proper A FCON components-see disclaimer below. Insert brace pipe thru fitting near pivot bolt. coos Max. Horizontal Load Tighten set bolt until head contacts bracket. FEATURES 30°thru 90° 2015 * Swivel allows attachment at any angle. *Visual inspection,verifies proper installation. Q Max.ASD Horizontal Load * Larger fastener hole available.-Consult factory. ORDERING-Part#,size-brace pipe and finish. 30°-44° 45°-59° 60°-74° 75°-90° 630 870 1620 1810 FASTENERS Specific AFCON products arc exclusively designed to be compatible ONLY with other AFCON products including parts and fasteners,resulting in a listed sway brace,restrainer or hanger assembly. Be advised the following warranty restriction will apply. DISCLAIMER-AFCON will NO!warrant against the failure of its products when used in combination with other products,parts or systems • not manufactured or sold by AFCON.AFCON shall NOT be liable under any circumstances whatsoever for any direct or indirect,incidental or consequential damages of any kind,including but not limited to loss of business or profit,when non-A FCON products have been.or are used. 5/15 ` • .e.....,,,,,, ,,,,,,:ty/Foolo P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 400 RISER CLAMP IRON PIPE r -• - PIPE A B C C C STOCK MAX.REC. SIZE SIZE LOAD LBS. 1 1/2" 10 3/8" 3/8" 1 1/2" 3/16"x1 1/4" 255 2" 10 3/4" 318" 2" 3116"x1 1/4" 255 f( i}f NMI a e 2 1/2" 11" 3/8" 2 1/8" 1/4"x1 1/4" 390 lel s1 3" 12" 3/8" 3 1/4"x1 1/4" 530 Q 1 \ 3 1/2" 13" 1/2" 3 5/16" 1/4"xl 1/4" 670 B B 4" 13 1/2" 1/2" 3 3/8" 1/4"xl 1/4" 810 5" 14 1/2" 1/2" 4" 1/4"x1 1/2" 1160 III 6" 15 1/8" 1/2" 4 1/2" 1/4"x2" 1570 8" 18 1/2" 5/8" 5 13/16" 3/8x2" 2500 NOTE:MAXIMUM TEMPERATURE:650°F ill SIZE- 1/2 thru 20 inch pipe. 1 MATERIAL-Carbon Steel. FINISH-Plain,E.G.,H.D.G.and S.S. LISTING/APPROVAL- S. EX 2551 11/2"-8"pipe. OSHPD OPA-0601 See Website. Itl CONFORMS WITH: Federal Specification .1 W W-H-171 E,type 8,3/4 thru 20 inch,and Manufacturers Standardization Society SP-69,type 8. FUNCTION-Used for supporting vertical piping. ORDERING-Part#,pipe size and finish. • 1/08 FireLock® Buterfly Valve ✓ctaul,ce Style 705 with Weatherproof Actuator 10.81 • Material Specifications: vik Body: Ductile iron conforming to ASTM A-536, grade 65-45-12 End Face, 2—6'150— 150 mm: Ductile iron conforming to ASTM A-536,grade 65-45-12 Seal Retainer, 8— 127200—300 mm: Ductile iron conforming to ASTM A-536,grade 65-45-12 Approvals/Listings: Coating: Black alkyd enamel c®, Fnn vas LPCB Disc: Ductile iron conforming to ASTM A-536,grade URN #G410001 104j/04 65-45-12,with electroless nickel coating conforming to See Victaulic Publication 10.01 for more details. ASTM B-733 Seat: Product Description: — 0 Grade "E" EPDM The Series 705 Butterfly Valve features a weatherproof actuator housing Approved for indoor or outdoor use, a Stems:416 stainless steel conforming to ASTM A-582 ductile iron body and disc with EPDM seats. Designed for fire protection services only. Victaulic FireLock Stem Seal Cartridge: C36000 brass Series 705 Butterfly Valve is cULus Listed, LPCB Listed, FM and VdS Approved for 300 psi/2068 kPa service. Bearings: Stainless Steel with TFE lining Contact Victaulic for details of agency approvals. • Stem Seals: EPDM Stem Retaining Ring: Carbon steel Actuator: 0 2—8"/50—200mm: Brass or bronze traveling nut on a steel lead screw, in a ductile iron housing ❑ 10— 12"/250—300mm: Steel worm and cast iron quadrant gear, in a cast iron housing Job/Owner Engineer System No. Spec Section Location Paragraph Contractor Approved Submitted By Date Date victaulic.com I Butterfly Valve I Series 705 I Publication 10.81 10.81 5662 Rev F Updated 11/2014 0 2014 Victaulic Company.All rights reserved. 1 .ctaulic victaulic.com I Butterfly Valve I Series 705 I Publication 10.81 Approvals and Listings: • f Approval/Listing Service Pressures Series 705 Butterfly Valve Size cULus FM ( Vds { i LPCB J I _ 2"/50 mm up to 300psi/2068kPa n/a { up to 300psi/2068kPa up to 300psi/2068kPa 2 1/2"/65 mm up to 300ps1/2068kPa up to 300psi/2068kPa n/a i up to 300psi/2068kPa 76.1 mm up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa 3'/80 mm up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa 4"/100 mm } up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa 5"/125 mm up to 300psi/2068kPa up to 300psi/2068kPa n/a up to 300psi/2068kPa 139.7 mm up to 300psV2068kPa up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa I 1 6"/150 mm up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa i up to 300psi/2068kPa ' 165.1 mm up to 300psi/2068kPa up to 300psi/2068kPa n/a up to 300psi/2068kPa } 8"/200 mm up to 300psi/2068kPa ( up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa 10"/250 mm up to 300psi/2068kPa up to 300psi/2068kPa n/a up to 300psi/2068kPa 127300 mm up to 300psi/2068kPa up to 300psi/2068kPa n/a ! up to 300psi/2068kPa i III 411 10.81 5662 Rev F Updated 11/2014 ©2014 Victaulic Company.All rights reserved. victaulic.com 2 ictaulid victaulic.com I Butterfly Valve I Series 705 I Publication 10.81 _b Dimensions: IIIA I I K 1 a.,-0 I 1 I III 111!1111, !. 110111111 II F � Null E F A D NOTE:OPTIONAL 1"/15MM TAP AVAILABLE. CONTACT VICTAULIC FOR DETAILS. Actual DimensionsIel Nominal Outside E to E I I I Size Diameter A B C D E F G DIA H ( J inches inches inches inches inches inches inches ( inches inches inches inches mm mm { mm ; mm i mm mm mm mm mm mm mm 2 2.375 4.25 2.28 6.41 _ 4.00 4.22 4.50 2.12 60.3 I 60.3 ( 108.0 i 57.9 162.8 101.6 107.2 114.3 1 53.8 21h 2.875 3.77 2.28 7.54 _ - 4.00 4.22 4.50 1.77 73 i 73.0 95.8 57.9 I 191.5 101.6 107.2 j 114.3 45.0 76.1 mm 3.000 3.77 228 I 7.54 - - 4.00 4.22 i 4.50 1.77 76.1 95.8 57.9 191.5 101.6 1072 114.3 45.0 3 3.500 3.77 2.53 7.79 _ I _ I 4.50 4.22 4.50 1.77 88.9 88.9 I 95.8 64.3 197.9114.3 107.2 114.3 45.0 108mm 4/50 4.63 2.88 8.81 - _ 1 5.50 4.22 I 430 2.20 1111 108.0 117.6 73.2 223.8 I i 139.7 107.2 i 114.3 55.9 4 4.500 4.63 2.88 8.81 _ _ 1 550 4.22 i 4.50 2.20 114.3 1143 117.6 73.2 223.8 139.7 ( 107.2114.3 55.9 i 5.250 5.88 3.35 10.88 6.56 6.19 630 2.58 133mm - - 160.0 65.5 133.0 149.4 85.1 276.4 166.6 157.2 - t 5.500 5.88 335 10.88 _ _ 6.56 6.19 ( 6.30 I 2.58 ' 139.7 mm 139.7 149.4 85.1 276.4 166.6 157.2 I 160.0 65.6 H- 5 5.563 5.88 3.35 10.88 - _ 656 6.19 630 258 1 141.3 141.3 _149.4 85.1 276.4 166.6 157.2 160.0 655^ ' 6.250 5.88 I 3.84 1138 i - 0.41 7.52 6.19 6.30 238 1 I 159 mm � 159.0 ' 149.4 975 289.1 10.4 191.0 1572 160.0 655 I 6.500 5.88 3.84 11.38 0.41 732 6.19 630 2.58 7 65.1 m m 165.1 149.4 97.5 289.1 - 10.4 191.0 157.2 160.0 65.5 I 6 6.625 5.88 3.84 11.38 _ 0.41 752 6.19 630 1.90 I 168.3 168.3 149.4_ 97.5_ 289.1 10.4 191.0 1572 160.0 48.3 I 8 8.625 j 5.33 5.07 13.53 0.80 1.47 10.00 6.19 8.10 233 i 219.1 219.1 _� 135.4 _ 128.8 343.6 203 373 254.0 1572 -205.7 592 1 10 10.750 6.40 6.37 15.64 1.41 1.81 1225 8.10 9.00 _ I273 273.0 162.6 161.8 3973 I 35.8 46.0 311.2 205.7 228.6 12 12.750 i 6.50 736 16.64 230 2.80 1 14.25 8.10 9.00 _ 323.9 323.9 l 165.1 186.9 422.7 58.4 71.1 I 362.0 205.7 228.6 10.81 5662 Rev F Updated 11/2014 ©2014 Victaulic Company.All rights reserved. victaulic.com 3 .ctaul.c` victaulic.com I Butterfly Valve I Series 705 I Publication 10.81 Performance: . The chart expresses the frictional resistance of Victaulic Series 705 Butterfly Valve in equivalent feet/ meters of straight pipe. Nominal I Outside Equivalent Size Diameter i mm mm Feet/m inches inches of pipe 2 2.375 6 50 603 _ 1.8 21 2.875 6 65 73.0 _ 1.8 76.1 mm 3.000 6 76.1 1.8 3 3.8 80 88.9.9 2.2.1 4 4.500 1 $ I- 100 i 114.3 2.4 108mm 108mm 2.. 4 5 I 5.563 12 125 141.3 3.7 133 mm 133 mm 3 7 739.7 mm 5.500 12 139.7 3.7 6 6.625 14 150 168.3 4.2 159 mm 159 mm 14 43 1 165.1 mm 1 6.500 14 • i 8 165.1 4.2 8.625 16 200 219.1 4.9 10 10.750 18 250 273.0 5.5 12 12.750 19 300 , 323.9 5.8 • 10.81 5662 Rev F Updated 11/2014 ©2014 Victaulic Company.All rights reserved. victaulic.com 4 xictaulid victaulic.com I Butterfly Valve I Series 705 I Publication 10.81 Performance: C,values for flow of water at+60°F/+16°C through a fully . open valve are shown in the table below. For additional details, contact Victaulic. Formulas for Cv values Formulas for Kv values ©P=Q2/C 2 Where: Where: AP=Qz/Ky2 v j Flow Coefficient I Cy ' I Flow Factor Ky Q=CvxOP 1 - Q=KvxVAP Q(Flow) i GPM I Q(Flow) mVhr 4P(Pressure Drop) ! psi I— AP(Pressure) ! bar Valve Size 1 Full Open I Valve Size Full Open Actual i ? Actual { Nominal I Outside I Nominal Outside i Size Diameter Flow Coefficient Size Diameter Flow Coefficient 1 inches inches C,, inches inches ' K mm mm mm mm 2 2375170 ) 2 2375 147 50 603 50 60.3 21/2 2.875 260 2 Y2 2.875 225 65 73.0 I 65 73.0 76.1 mm 1 76.13.000 i 260 76.1 mm 76.00 225 3 1 3.500 E 440 i 3 i 3.500 380 80 88.9 -j80 ` 88.9 , 4 I 4.500 i 4 4.500 820710 100 114.3 I 710 100 1 114.3 108mm 1 108mm 820 108mm 108mm 710 5 5.563 1200 5 5.563 1040 125 141.3 125 141.3 133mm 133mm j 1200 — 133mm 133mm 1040 • y 5.500 SS00 139.7mm 1200 139.7mm 1040 139.7 139.7 6 6.625 1800 6 6.625 1560 150 1683 150 1683 159 mm ! 159 mm i 1800 159 mm 159 mm 1560 ,— J 165.1 mm 6.500 1800 165.1 mm 6.500 1560 165.1 165.1 8 8.625 3400 8 8.625 2940 200 i 219.1 I 200 219.1 i 10 i 10.750 5800 10 10.750 I 5020 _ 250 i 273.0 250 273.0 I 12 1 12.750 f12 12.750 ' 300 323.9 I 9000300 323.9 7790 411111 10.81 5662 Rev F Updated 11/2014 ©2014 Victaulic Company.All rights reserved. victaulic.com 5 •ctaul.c victaulic.com I Butterfly Valve I Series 705 I Publication 10.81 Switch and Wiring: LIVED NNEIONBOx III CONDUIT '9� 1. The supervisory switch contains two single pole, _�A�«•- double throw, pre-wired switches. ��t l�� SPT r ,��. .. Err CONDUn CONNECTORS '�', 2. Switches are rated: r WIRE NUTS 10 amps @ 125 or 250 VAC/60 Hz 0.50 amps C© 125 VDC EIRE ALARMCONTROTO END-OOLINE RELATOR. 0.25 amps C/ 250 VDC `5 DRNEX I"DICAT°R CIRCUIT 3. Switches supervise the valve in the "OPEN" position. SWITCH CONTACTRATINTO _, 10A IOR AT 125 AND �I 5. One switch has two#18 insulated wires per terminal, 250VAC. OSA AT125 VDC, WEI which permit complete supervision of leads(refer 025PT2TV°° M. � EEL. to diagrams and notes below).The second switch -- —EMI °" 4 VOLTAGE has one#18 insulated wire per terminal.This double Switch 1:2 leads per terminal Switch 2:1 lead per terminal circuit provides flexibility to operate two electrical devices at separate locations, such as an indicating light and an audible alarm, in the area that the valve NOTE: The above diagram shows a connection between is installed. the common terminal (yellow–Si and yellow-with- orange stripe–S2)and the normally closed terminal 6. A#14 insulated ground lead (green) is provided. (blue–Si and blue-with-orange stripe–S2). In this Switch#1 =Si example,the indicator light and alarm will stay on until the valve is fully open. When the valve is fully open,the For connection to the supervisory circuit of a UL indicator light and alarm will go out. Cap off any unused Listed alarm control panel wires(e.g. brown with orange stripe). Switch#2=S2 Only Si (two leads per terminal) may be connected to Auxiliary switch that may be connected to auxiliary the fire alarm control panel. • devices, per the authority having jurisdiction The connection of the alarm switch wiring shall be in accordance with NFPA 72 and the auxiliary switch per Normally Closed: (2) Blue NFPA 70(NEC). si Common: (2)Yellow Normally Closed: Blue with Orange Stripe S2 Normally Open: Brown with Orange Stripe Common: Yellow with Orange Stripe Installation Note Reference should always be made to the 1-100 Victaulic Field Installation Handbook for This product shall be manufactured by Victaulic or to Victaulic specifications.All products the product you are installing.Handbooks are included with each shipment of Victaulic to be installed in accordance with current Victaulic installation/assembly instructions. products for complete installation and assembly data,and are available in PDF format Victaulic reserves the right to change product specifications,designs and standard on our website at www.victaulic.com. equipment without notice and without incurring obligations. Warranty Trademarks Refer to the Warranty section of the current Price List or contact Victaulic for details. Victaulice is a registered trademark of Victaulic Company. • W.81 5662 Rev F Updated 11/2014 ®2014 Victaulic Company.All rights reserved.- victaUllC.com 6 ictau6c FireLock® Check Valves ✓�tauliC Series 717 & 717H 10.08 111/ Grooved ends allow fast, easy installation with just • two Victaulic couplings or the valve may be mounted to CLto Victaulic flanged Style(ANSI 741 Vic-Flange®150)equipment or Styleusing 744 FireLoeitherck flange adapters on either end. Series 717 Series 717 (21/-3'/65-80 mm) (4—12'/100-300 mm) I Series 717H High Pressure Check Valve (2—3"/50—80 mm) Approvals/Listings: c®L us 1 Fs LPCB a. usreo See Victaulic Publication 10.01 for more details. The FireLock Series 717 Check Valve and Series 717H High Pressure Check Valves are CAD designed for hydrodynamic efficiency and available in 2750 mm—3780 mm (Series 717H)and 2 1/2"165 mm— 127300 mm (Series 717)sizes. • Series 717H valves are cULus Listed and FM Approved for service up to 365 psi/2517 kPa. See chart below for approved services for the Series 717 valves. In both valve designs, the single-disc mechanism incorporates a spring-assisted feature for nonslamming operation. This spring-assisted, single-disc design achieves a leak-free seal with as little as 5ft/1.5m of head. Series 717 and 717H FireLock Check Valves can be installed either vertically(flow upwards only)or horizontally. A cast flow arrow indicator is provided to assist with proper valve orientation. Both valves include upstream and downstream pressure taps. Each valve is factory-tested to the rated working pressure. For systems requiring a Riser Check option, refer to publication 10.09. . Job/Owner Engineer System No. Spec Section Location Paragraph Contractor Approved Submitted By Date Date i__._._ 0 Check Valve I FireLock®I Series 717&717H I Publication 10.08 vista ic.c •ctaulic` victaulic.com 1 Check Valve I Firelock®I Series 717&717H I Publication 10.08 Material Specifications: Spring:All sizes Type 302/403 Stainless Steel • Housing: Shaft Plug: Ductile iron conforming to ASTM A-536, grade • Series 717H (2—3"/50—80 mm): Type 416 Stainless 65-45-12. Ductile iron conforming to ASTM A-395, Steel grade 65-45-15, is available upon special request. • Series 717 (2 'h— 12"/65—300 mm): Carbon steel zinc plated Body Coating: Series 717H Body: Black Paint Pipe Plug: Series 717H Endface: Electroless Nickel • Series 717H (2—3"/50—80 mm): carbon steel zinc Series 717 (2 1—3"): PPS Coating plated Series 717 (4— 12"): Black Paint • Series 717 (4— 12"/100—300 mm): Carbon steel zinc Body Seat: plated Series 717H—Nitrile 0-ring installed into an electroless nickel plated endface Series 717(2 1—3"): PPS Coated ductile iron Series 717 (4— 12"): Electroless Nickel plated Disc Seal or Coating: (specify choice') ❑ Grade "T" nitrile(Series 717H Only) Nitrile(Orange color code).Temperature range—20°F to +180°F/-29°C to+82°C.Recommended for petroleum products,air with oil vapors,vegetable and mineral oils within the specified temperature range;except hot,dry air over+140°F/+60°C and water over+150°F/+66°C. NOT RECOMMENDED FOR HOT WATER SERVICES. • ❑ Grade "E" EPDM (Series 717 Only) EPDM (green color code).Temperature range-30°F to +230°F/-34°C to+110°C. Recommended for cold and hot water service within the specified temperature range plus a variety of dilute acids,oil-free air and many chemical services. NOT RECOMMENDED FOR PETROLUEM SERVICES. ' Services listed are General Service Recommendations only.It should be noted that there are services for which these gaskets are not recommended.Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service recommendations and for a listing of services which are not recommended. Discs: • Series 717H (2—3750—80 mm): CF8M Cast Stainless Steel • Series 717 (2 ' —3"): Aluminum bronze with elastomer seal • Series 717 (4—127100—300 mm): Elastomer encapsulated disc with electroless nickel plated seat Shaft: • Series 717H (2—3750-80 mm): Brass • Series 717 (2 1—3"): Type 416 Stainless Steel • Series 717 (4— 12"/100—300 mm)Type 316 Stainless Steel victaulic.com 2 ctaul,c Check Valve I Firelock® I Series 717 &717H I Publication 10.08 Approval/Listing: Approval/Listing Service Pressures • Series 717H — Size ( cULus ? FM LPCB 3 Vds 2°/50 mm ( up to 365 psi/2517 kPa j up to 365 psi/2517 kPa j up to 365 psi/2517 kPa i up to 365 psi/2517 kPa 2/2"/65 mm up to 365 psi/2517 kPa up to 365 psi/2517 kPa ( up to 365 psi/2517 kPa I up to 365 psi/2517 kPa 76.1 mm up to 365 psi/2517 kPa up to 365 psi/2517 kPa up to 365 psi/2517 kPa up to 365 psi/2517 kPa 3"/80 mm up to 365 psi/2517 kPa ' up to 365 psi/2517 kPa up to 365 psi/2517 kPa up to 365 psi/2517 kPa 4"/100 mm n/a n/a n/a n/a — 5"/125 mm n/a n/a n/a n/a 139.7 mm n/a n/a I n/a n/a 6"/150mm n/a n/a j n/a n/a ( ! --- —i- ——_. 165.1 mm n/a n/a n/a n/a 8"/200mm n/a n/a n/a n/a f — — — .—i 10"/250 mm i n/a n/a i n/a n/a 127300mm n/a n/a n/a n/a i Approval/Listing Service Pressures III Series 717 I Size --i- 2"/50 cULus {i— FM LPCB Vds 2"/50mm n/a � n/a n/a n/a 21/2'Y65 mm up to 250 psi/1725 kPa n/a up to 365 psi/2517 kPa n/a 76.1 mm up to 250 psi/1725 kPa n/a up to 365 psi/2517 kPa up to 16bar/232 psi 3"/80 mm ( up to 250 psi/1725 kPa n/a up to 365 psi/2517 kPa up to 16bar/232 psi 4'/100 mm ? up to 365 psi/2517 kPa up to 365 psi/2517 kPa up to 365 psi/2517 kPa up to 16bar/232 psi 5"/125 mm up to 365 psi/2517 kPa up to 365 psi/2517 kPa Iup to 365 psi/2517 kPa I n/a 139.7 mm up to 365 psi/2517 kPa 1 up to 365 psi/2517 kPa up to 365 psi/2517 kPa i up to 16bar/232 psi T 6"/150 mm up to 365 psi/2517 kPa , up to 365 psi/2517 kPa up to 365 psi/2517 kPa - up to 16bar/232 psi —a- 165.1 mm up to 365 psi/2517 kPa j up to 365 psi/2517 kPa up to 365 psi/2517 kPa j n/a 8"/200 mm up to 365 psi/2517 kPa up to 365 psi/2517 kPa up to 348 psi/2400 kPa up to 16bar/232 psi t .___.... i 10"/250 mm—' up to 250 psi/1725 kPa up to 250 psi/1725 kPa up to 1725 kPa/250 psi n/a _ —1 12"/300 mm + up to 250 psi/1725 kPa { up to 250 psi/1725 kPa ( up to 1725 kPa/250 psi n/a • victaulic.com 3 ✓ctaul.c` Check Valve I Firelock!I Series 717&717H I Publication 10.08 Dimensions-Series 717: III 4 A -> R !a- q P. U_ il fIII �II� DE Ut it o# I�A� B �K� ! LK-a] E .. O �_ It e---B--> --)i J IF- B >�J,F Q '° 0 %z"NPT Upstream Drain Q/�"NPT Upstream Drain I III j a) 'k"NPT Downstream Drain ®1"NPT Downstream Drain W ® 2"NPT(Drain Optional) Typical 2 1-3765-80 mm Typical 4-87100-200 mm Typical 10-127250-300 mm F. I 1 I i i Actual Dimensions Approx. Nominal 1 Outside E to E - 1 Weight Size I Diameter , A B C D E J K P R Each I inches 1 inches inches inches inches inches inches inches inches inches inches lbs. mm mm mm mm mm _ mm mm mm mm mm mm kg 2' 2.875 3.88 4.26 3.57 _ _ _ - - - 3.6 65 73.0 99 108 91 1.6 76.1 mm 3.000 i 3.88 4.26 3.57 - - _ - - - 3.6 I 76.1 99 108 91 1.6 1 3 3300 4.25 5.06 4.174.5 1 80 88.9 108 129 106 I - - J 2.0 -- - -t- 4 4 4.500 9.63 6.00 3.88 2.75 350 2.00 4.50 3.50 335 I 20.0 100 1143 245 152 99 70 89 51 114 89 85 9.1 5 5.563 10.50 6.80 4.50 _ 4.17 2.15 5.88 I 4.08 3.98 27.0 125 141.3 267 173 I 114 1 106 55 149 ! 104 101 12.3 139.7 mm 5.500 10.50 6.80 450 - 4.17 2.15 5.88 4.08 3.98 , 27.0 139.7 267 173 114 106 55 149 104 I 101 12.3 6 6.625 ; 11.50 8.00 5.00 _ 4.50 238 6.67 4.73 3.89 38.0 150 168.3 292 203 127 114 61 169 120 99 17.2 III 165.1 mm 6.500 1150 8.00 5.00 - 4.50 238 6.67 4.73 3.89 38.0 165.1 292 203 127 114 61 169 120 99 17.2 8 8.625 ( 14.00 9.88 6.06 5.05 5.65 2.15 8.85 5.65 5.75 64.0 200 219.1 356 251 154 128 144 55 225 144 146 29.0 10 10.750 17.00 I 12.00 7.09 5.96 6.69 2.15 10.92 6.73 I 100.0 250 273.0 432 305 180 151 170 55 277 171 I 45.4 { 12 12.750 19.50 14.00 1 8.06 6.91 7.64 2.51 12.81 7.73I 140.0 300 323.9 I 495 356 - 205 176 194 64 925 196 635 Dimensions-Series 717H: A 4--B---s 'I%II' * D R J Typical 2750 mm-3780 mm I Dimensions Approx. Nominal C E to E Weight Size i A B C D I E J K P R Each inches inches inches inches inches inches inches I inches inches l inches lbs. mm mm mm mm mm j mm mm mm ' mm _mm kg 2 8.66 { 6.46 3.23 1.48 3.02 2.80 - 4.25 10.7 50 219.8 1 164.1 82.1 37.5 76.7 j 71.0 108.0 i 4.9 2' 9.37 6.94 3.31 1.66 3.40 3.38 438 13.8 65 238.0 1763 84.1 42.2 86.4 85.9 - - i 111.3 6.3 9.37 ] 6.94 I 331 1.66 I 3.40 3.38 , 4.38 � 13.8 i 76.1 mm - _238.0 1763 84.1 42.2 86.4 85.9 111.3 = 6.3 • 3 9.62 7.44 3.53 1.91 3.65 3.38 _ _ 4.63 20.0 80 2443 189.0 89.7 48.5 92.7 85.9 i 117.6 9.1 victaulic.com 4 Jctaulid Check Valve I Firelock® I Series 717 &717H I Publication 10.08 Flow Characteristics The charts below express the flow of water at 60°F/16°C through valve. S717H/717HR III 10 0. 0 1 ye,„ d 1 ig y d 0.1 10 100 1000 Flow-GPM S717H/717HR 100.00 FF FF d ^b F R3 F FF 1^ 1 F oz 4r 1 FF FF , p 10.00 ,\ �.' c,..1 � \ 3,'' ��O -+ e F w o . N 0 � N •a 1.00 10 100 1000 10000 100000 Flow Rate-Litres/min. 1 III victaulic.com 5 ✓ctaul.c° Check Valve I Firelock® I Series 717 &717H I Publication 10.08 • Flow Characteristics • The charts below express the flow of water at 60°F/16°C through valve. S717/717R 10 �c FF F F � F N ^b FF •o \ \ FF of yF \�g J 1 Co N N o' 0.1 10 100 1000 10000 100000 Flow-GPM S717/717R 10 • to. FF FF � 4z- F AFF a Fo , F FF o • mF �' ti of 8 ry .'y' 1.0 y \ o J 1 3 N N G1 0.1 10 100 1000 10000 100000 Flow-GPM Installation Note Reference should always be made to the 1400 Victaulic Field Installation Handbook for This product shall be manufactured by Victaulic or to Victaulic specifications.All products the product you are installing.Handbooks are included with each shipment of Victaulic to be installed in accordance with current Victaulic installation/assembly instructions. oroducts for complete installation and assembly data,and are available in PDF format Victaulic reserves the right to change product specifications,designs and standard Sn our website at www.victaulic.com. eouiprnent without notice and without incurring obligations. Warranty Trademarks Refer to the Warranty section of the current Price List or contact Victaulic for details. Victaulic and FireLock are registered trademarks of Victaulic Company. • 10.08 1479 Rev.R Undated 05/2014 ©2014 Victaulic Company.All rights reserved. victaulic.com 6 �ctaulic Check Valves ► ®►G UL/ULC listed and FM approved* F P P , Description Check valves feature cast brass** bodies with a spring loaded clapper assembly making this valve suitable for vertical or horizontal installations. Features metal faced of 4t clapper with 0-ring seat. Rated to 300 psi.Valve bodies are tapped and plugged 1/2" IPS for additional equipment such as a ball drip valve when used in conjunction with a m ; Fire Department Connection or a pressure gauge when used in a supply line. Installation Specifications Install in accordance with approved installation practices. Use an approved Mrial: thread sealant such as PipeFit Thread SealingPaste with PTFE on all threaded CastaBra p Brass*" connections. Make sure that proper lubrication has been applied to groove coupling gaskets for groove end valves. Pressure Rated: 300psi DO NOT OVER TIGHTEN THREADED CONNECTIONS. OVERTIGHTENING Size: • MAY CAUSE DISTORTION OF THE BODY AND THREADS OF THE VALVE 11/2" IPS* LEADING TO IMPROPER PERFORMANCE AND PRODUCT FAILURE. 2" IPS 21/2" IPS 3" IPS 4" IPS Configurations: MNPT x GRV MNPT x FNPT GRV x GRV FNPT x FNPT 1 '/"only **Contains lead.Not for use in water systems intended for human consumption. `1 1/2"size is ULJULc listed but not FM approved 3 U CARLSBAD198 ,ONSHEAD CA 92010AVE TEL+1 760 599-1168 j +1 800 344-1822 FAX+1 800 344-3775 • ©2015 Fire Protection Products,Inc. C U` US LISTED APPROVED i► tlTV. . I1 F P P r Material Specifications 1 / # IIII, 4 I / `/ 9/ 0 (Q) , / ri-re 4.402 / / / fir 40,-,K. /- 2 los A 1111 .• ! '4\ N 1. BODY-BRASS-ASTM C37700 2. CLAPPER -BRASS-ASTM C37700 3. PIN BRASS ASTM C86300 ��\�i. `� 4. SPRING -STAINLESS STEEL 5 5. O-RING-NBR-1052 6. THREADED PORT- BRASS NPT PLUG 1 c '/4"ON 1 1/"-3"VALVES % V 1/2"ON 4"VALVES d' • 1111 11. 1 FPP1e Dimensions WIDTH I I 1 illill LENGTH %MINIM liallnlid 1 • SIZE ITEM# CONFIGURATION LENGTH WIDTH LENGTH WIDTH (IN) (IN) (MM) (MM) 1 1/2" 09-574-00 MNPTXGRV 615/16 41/8 176 105 1 1/2" 09-575-00 MNPTX FNPT 6 1/16 4 1/8 154 105 1 1/2" 09-576-00 GRV X GRV 6 15/16 4 1/8 176 105 1 1/2" 09-577-00 FNPTXFNPT 5 9/16 41/8 150 105 2" 09-568-00 MNPTXGRV 61/4 41/8 157 105 2" 09-570-00 MNPT X FNPT 5 3/4 4 1/8 146 105 . 2" 09-572-00 _- _. •. . 4 1/8 157 105 2 1/2" 09-562-00 MNPTXGRV 615/16 41/8 176 105 2 1/2" 09-564-00 MNPTX FNPT 6 1/4 4 1/8 159 105 2 1/2" 09-566-00 GRV X GRV 6 15/16 4 1/8 176 105 3" 09-556-00 MNPTXGRV 613/16 51/8 173 128 3" 09-558-00 MNPTX FNPT 6 5/8 5 1/8 167 128 3° 09-560-00 GRV X GRV 6 13/16 5 1/8 173 128 4" 09-550-00 MNPT XGRV 8 1/8 5 5/8 206 142 4" 09-552-00 MNPTX FNPT 8 5 5/8 202 142 4" 09-554-00 GRV X GRV 8 5 5/8 202 142 III 11111►. Swing Check Valve r 1 `AW r Full Floating Clapper Assembly Description :, The bronze*swing check valve features a full floating clapper assembly that provides for a positive seal each time the valve is cycled. This feature improves the swing check valves ability to "clear" any debris that may be present in the water supply.The seat material is NBR which provides for a positive seal even under light residual pressures. '* Installation Warning Specifications ecifications For horizontal installation only. The DO NOT OVER TIGHTEN. Over female by female swing check valve tightening during installation will Valve Body: Cast Bronze' should be installed in accordance crack the valve body. Evidence (85-5-5-5) with commonly used installation of overtightening may not be practices for the fire sprinkler industry. readily visible or apparent upon Clapper Assembly: ioForged Brass Proper seal of the threads can be pressurization. accomplished by applying a liberal Seat: amount of PTFE based thread seal- No user serviceable parts. NBR(Chloramine Resistant) ant such as PipeFit®Thread Sealant Sizes: Paste or PTFE Tape. Never use tape 1/2" IPS and paste together. This will cause 2" IPS excessive stress on the threaded Female by female connection leading to failure of the Rated Pressure: valve. Do not exceed one full turn 250 psi past hand tight when installing male 'Contains lead.Not for use in threads into the check valve. water systems intended for human consumption. 3198 LIONSHEAD AVE CARLSBAD, CA 92010 TEL+1 760 599-1168 +1 800 344-1822 FAX+1 800 344-3775 2016 Fire Protection Products.Inc. 111111, . . Three-way Brass Valve F P P I® 1/4" IPS UL/ULC Listed* 300 psi Description The 1/4" IPS three-way female threaded valve is used to facilitate the installation of sprinkler system pressure gauges.The valve provides for one inlet and ° .-- two outlets.This design allows for replacement of the system gauge without shutting down the water supply to the sprinkler system.This design also allows Authorities' Having Jurisdiction to test system pressure with an additional .,ro„r, fir. gauge through the second outlet. (The second outlet is normally plugged during installation with a'/4” IPS P�P i eplug.) Installation Specifications Installation of the three-way valve can be accomplished with normal field installation tools. Make sure the valve is installed according to the flow indication Materials: Seat- Brass arrow that has been cast into the valve body. The most common installation Body-Brass allows for a'/4" IPS nipple between the valve and the water supply being Handwheel-Iron measured. This assures there will be ad-equate spacing for the sprinkler system Sizes: gauge from the riser. Use either PTFE Pipe Thread Sealing Tape or a suitable pipe 1/4" IPS • thread sealant such as PipeFit®Thread Sealant Paste with PTFE when installing the valve. Working Pressure: 400 WOG DO NOT OVERTIGHTEN THREADS.OVERTIGHTENING MAY CAUSE VALVE FAILURE. *UUULC Listed 2R97 3198 LIONSHEAD AVE CARLSBAD, CA 92010 TEL+1 760 599-1168 � +1 800 344-1822 FAX+1 800 344-3775 ©2012 Fire Protection Products,Inc. � C Vii. LISTED LISTED Ii iiif , i arras BE 4077 Airpark Dr.Standish, MI 48658•989-846-4583•www.globesprinkler.corn FIRE SPRINKLER CORPORATION Technical Support•989-414-2600•techservice@globesprinkler.com MODEL UMC UNIVERSAL MANIFOLD CHECK ASSEMBLY (With or Without Control Valve) 1%", 1%", 2", 21/2", 76.1mm, 3", 4", 6", 165.1mm, 8" GENERAL DESCRIPTION The Globe Series"UMC" Universal Manifold Check is a first of its kind, UL Listed and FM Approved, complete floor con- trol station or shotgun riser assembly. It is pressure rated for 300 psi (20,6 bar). It provides the most compact "footprint" R , while delivering all of the necessary components for your N, 4 floor control station as required by the NFPA Standards. With its multiple available configurations, it allows the con- tractor to order the suitable configuration for the site spe- cific needs. The "UMC" Universal Manifold Check is more •••. than just a traditional stand-alone manifold. It serves as a 11 complete floor control station as well as a complete shot- gun riser assembly inclusive of Control Valve with Internal .- s Supervisory Switch; Check Valve; Flow Switch; Test and Drain Assembly;Adjustable Pressure Relief Valve Assembly pre-piped to drain; supply gauge (4", 6" and 8") and system MODEL UMC UNIVERSAL MANIFOLD gauge (1 1/4" through 8"). The "UMC" Universal Manifold CHECK ASSEMBLY Check replaces the need to order individual "Riser Mani- CHECK ASSEMBLY folds" plus control valves, check valves, and relief valve kits as all of these components are integrated into the one SHOTGUN RISER ASSEMBLY compact design, saving space as well as the labor to con- nect these separate components. For sizes 3" and smaller, "Shotgun Riser Assemblies"are those assemblies which are an 18" long stainless steel braided flexible hose is included typically installed in vertical orientations on individual sys- with the UMC for connecting the Test and Drain valve to a tern Risers. The Globe "Shotgun" Riser Manifold Assembly drain stack. The design takes into account both "left-hand" is available in 4 inch (DN 100), 6 inch (DN 150), and 8 inch and "right-hand" orientations. (8" version available preas- (DN 200) sizes and is equipped with a control valve; check sembled in right-hand orientation only) valve; flow switch; test and drain valve with NFPA required pressure relief valve; 2 gauges (system and supply). Sizes FLOOR CONTROL ASSEMBLY 4 inch (DN 1.00), 6 inch (DN 150), and 8 inch (DN 200) are equipped with a pressure gauge on both system side and The UMC may be utilized to meet the NFPA 13 require- supply side of the check valve clapper. ments for Floor Control Valve Assemblies where there are multistory buildings exceeding two stories in height requir- TECHNICAL DATA ing zoning by floor or whenever separate control and floor Approvals zoning is specified. The UMC has been engineered with pp space savings in mind for those commonly installed appli- • cULus cations in stairwell landings and small alcoves. All UMC • FM assemblies include the NFPA 13 required Listed Pressure Maximum System Working Pressure Relief Valve which is pre-piped to drain. The relief valve is preset for 175 psi and is adjustable to 310 psi for high pres- . 300 psi (20.6 Bar) sure system conditions. In addition to the relief valve, the End Connections UMC is equipped with a Test and Drain Valve.The Test and • See Table A Drain Valve contains a test orifice of K2.8 so that it may be Materials of Construction utilized for flow testing any system with sprinklers having K- . See Figure 1 Factors of 2.8 or larger. g Note:NFPA 13 requires that a test connection providing a flow rate equal to or less than one sprinkler of a type having the smallest orifice on the system is *Multiple Patents Pending to be provided. A pressure gauge is provided above the check valve clapper for sizes 1'/"through 3"to meet the gauge requirement per NFPA 13 for Floor Control Assemblies. Typically the supply side gauge is not required for multistory buildings with floor control stations as a system gauge would be on the main feed/riser but all Model UMC Manifold Check Valves are equipped with a 1/4" (DN 8) port below the clapper to ac- commodate a second gauge if desired. NOV 2018 GFV-120 Page 1 of 11 A Io 6 1 a II psi� = _ 11-2) 1 i 12 • . 8 'y �/ t © ,O..!ME 0 ('®`� © grIAD ��— • �_ 101.��J'1 AP l� ~ —ail i) di --wirfix 71 III `b sults ��� 4 ����'� 3 Q � 13 4I� Its milr 4 na. ���NEBO 4,107 ill !II 1.6, 1 . / in pi ft s II ili5::4,jl II , • Ali=i 1 �'�';/' s ; ! SEC!DNAA 1 11141A ITEM DESCRIPTION MATERIAL NO. 1 UMC VALVE BODY DUCTILE IRON 2 RECESSED HEX PLUG STAINLESS STEEL 3 FLOW SWITCH SEE FLOW SWITCH TECHNICAL LITERATURE 4 RIGID COUPLING SEE COUPLING TECHNICAL LITERATURE 5 BUTTERFLY CONTROL VALVE SEE GLOBE BUTTERFLY CONTROL VALVE TECHNICAL LITERATURE WITH INTERNAL SUPERVISORY SWITCH 6 PRESSURE GAUGE PLASTIC 7 THREEWAY VALVE BRONZE 8 UMC COVER PLATE DUCTILE IRON 9 BOLT STAINLESS STEEL 10 FLOW SWITCH ADAPTER DUCTILE IRON 11 MODEL UTD TEST AND DRAIN SEE GLOBE TECHNICAL DATASHEET GFV570 12 MODEL ARV ADJUSTABLE RELIEF VALVE SEE GLOBE TECHNICAL DATASHEET GFV575 13 FLOW SWITCH PLUG DUCTILE IRON 14 UMC VALVE CLAPPER STAINLESS STEEL 15 UMC VALVE CLAPPER RETAINING BOLT STAINLESS STEEL 16 UMC VALVE CLAPPER RETAINING NUT STAINLESS STEEL 17 UMV VALVE HINGE PIN STAINLESS STEEL 18 CLAPPER FACING RETAINING RING STAINLESS STEEL 19 CLAPPER FACING FfPM 20 FLOW SWITCH PLUG BOLT STAINLESS STEEL 21 CLAPPER SPRING STAINLESS STEEL NOTE: •4"(DN100)shown as reference •See ordering procedure for replacement part kits and Table A through G for part numbers for all sizes and configurations •Flow switch rotated 90 degrees on 1-1/4"through 2 112"sizes FIGURE 1: MODEL UMC MANIFOLD CHECK ASSEMBLY MATERIALS OF CONSTRUCTION NOV 2018 GFV-120 Page 2 of 11 MODEL UMC MANIFOLD CHECK VALVE ASSEMBLY • LEFT HANDED VS RIGHT HANDED Both the shotgun riser assembly and the floor control tion of the Model UTD Test and Drain determines the station assembly are available as left handed or right "Hand" of the valve. If the Model UTD Test and Drain handed assembly. The determining factor of the left is connected to the port on the right side of the valve handed vs right handed is the position of the Model body, it is considered a right handed assembly. If the UTD Test and Drain. While looking at the faceplate Model UTD Test and Drain is connected to the port on with the Model UMC valve in the vertical orientation the left side of the Model UMC valve the assembly is and flow upward (shotgun riser orientation), the posi- considered left handed. TEST AND DRAIN i; tIt TEST AND DRAIN ASSEMBLY UMC BODY _ ASSEMBLY III ig re I LIA ,* - ,,,,,,, 03 k.,4-i„ *II s j, MIRRORED PORTS FOR �� ®Av , (-4&--- ) )` ALTERNATE TEST AND • Id ,�+�++� / DRAIN LOCATIONS \ .�L J.�i r, 1 ,. Oa DIO t 1 �'-- 7MiCktO CIO it IF L_____y i Il►\ /i.,�,' FLOW SWITCH---____ '•" iii ,��•, !II■� C71 \l�lij� __________----F !Nit C71���L�J j� NOTE:SUPPLY GAUGE "% ��I' ' �111.,� ". \�. \', NOTE.SUPPLY GAUGE p I NOT INCLUDED ON 3" 1"' NOT INCLUDED ON 3" ASSEMBLY ��/-el � �I ' J '.� ASSEMBLY ial l • II. in '�`�—��iff ���i� BUTTERFLY VALVE - -: I � � � i� IN AO li: t i:. I 1 FLOW FLOW LEFT HANDED ASSEMBLY RIGHT HANDED ASSEMBLY CONFIGURATION REPRESENTATIVE OF SIZES 3"THROUGH 8" (8"version available preasssembled right-hand only) MIRRORED FLOW SWITCH FLOW SWITCH MIRRORED PORT6-1 PORT BUTTERFLY VALVE „...,.„,,--ii �� ,,.,90)..---711 ' ® Vii/ FLOW ; II ii op 1 ® te a \\ G-,� . I 40 e� I € . o !_ 1{91 \ . `i „ lij -As il› . � e .1_ .�� UMC BODY :_F::14. ,�„�„�, ,- UMC BODY Tar 101 Ernt-,p- — IIS, 4 -ion— �� _ '-=1 lltli-I. 11110P iii El e - .1 '�I_► TEST AND DRAIN TEST AND DRAIN llIm ASSEMBLY ASSEMBLY Lato.,,,,.;r;;, ,,I'J' LEFT HANDED ASSEMBLY RIGHT HANDED ASSEMBLY • CONFIGURATION REPRESENTATIVE OF SIZES 1 1/4”THROUGH 2 1/2" FIGURE 2: MODEL UMC MANIFOLD CHECK VALVE ASSEMBLY LEFT HANDED VS RIGHT HANDED NOV 2018 GFV-120 Page 3 of 11 TABLE A: 1 1/4" MODEL UMC ASSEMBLY CONFIGURATIONS ASSEMBLYAPPROXIMATE UMC BODY MODEL UTD CONTROL SHIPPING • SIZE END TEST AND PART NUMBER R-RIGHT VALVE CONNECTIONS DRAIN SIZE WEIGHTS L-LEFT LBS. (kg) 1 1/4" R GL300T MXF THREADED 1" 317800-R-B-H 24.0 (10.9) 1 1/4" R NONE MXF THREADED 1" 317800-R-H 19.0 (8.6) 1 1/4" L GL300T MXF THREADED 1" 317800-L-B-H 24.0 (10.9) 1 1/4" L NONE MXF THREADED 1" 317800-L-H 19.0 (8.6) 1 1/4" R NONE GXG 1" 317843-R-H 19.0 (8.6) 1 1/4" R GL300G GXG 1" 317843-R-B-H 24.0 (10.9) 1 1/4" L NONE GXG 1" 317843-L-H 19.0 (8.6) 1 1/4" L GL300G GXG 1" 317843-L-B-H 24.0 (10.9) TABLE B: 1 1/2" MODEL UMC ASSEMBLY CONFIGURATIONS ASSEMBLYAPPROXIMATE UMC BODY MODEL UTD SIZE CONTROL END TEST AND PART NUMBER SHIPPING R-RIGHT VALVE CONNECTIONS DRAIN SIZE WEIGHTS L-LEFT LBS. (kg) 1 1/2" R GL300T MXF THREADED 1" 317803-R-B-H 24.0 (10.9) 1 1/2" R NONE MXF THREADED 1" 317803-R-H 18.3 (8.3) 1 1/2" L GL300T MXF THREADED 1" 317803-L-B-H 24.0 (10.9) 1 1/2" L NONE MXF THREADED 1" 317803-L-H 18.3 (8.3) 1 1/2" R NONE GXG 1" 317844-R-H 18.3 (8.3) 1 1/2" R GL300G GXG 1" 317844-R-B-H 24.0 (10.9) 1 1/2" L NONE GXG 1" 317844-L-H 18.3 (8.3) 1 1/2" L GL300G GXG 1" 317844-L-B-H 24.0 (10.9) • TABLE C: 2" MODEL UMC ASSEMBLY CONFIGURATIONS ASSEMBLYAPPROXIMATE UMC BODY MODEL UTD CONTROLSHIPPING SIZE R-RIGHT VALVE END TEST AND PART NUMBER WEIGHTS L-LEFT CONNECTIONS DRAIN SIZE LBS. (kg) 2" R GL300G GXG 1" 317806-R-B-H 26.0 (11.8) 2" R NONE GXG 1" 317806-R-H 19.2 (8.7) 2" L GL300G GXG 1" 317806-L-B-H 26.0 (11.8) 2" L NONE GXG 1" 317806-L-H 19.2 (8.7) TABLE D: 2 1/2" (DN65) / 76.1 MM MODEL UMC ASSEMBLY CONFIGURATIONS ASSEMBLYAPPROXIMATE UMC BODY MODEL UTD SIZE CONTROL END TEST AND PART NUMBER SHIPPING R-RIGHT VALVE DRAIN SIZE WEIGHTS L-LEFT LBS. (kg) 2 1/2" R GL300G GXG 1 1/4" 317809-R-B-H 31.0 (14.1) 2 1/2" R NONE GXG 11/4" 317809-R-H 23.5 (10.7) 2 1/2" L GL300G GXG 1 1/4" 317809-L-B-H 31.0 (14.1) 2 1/2" L NONE GXG 1 1/4" 317809-L-H 23.5 (10.7) 76.1 mm R GLR300G GXG 1 1/4" 317809-D-R-B-H 31.0 (14.1) 76.1 mm R NONE GXG 1 1/4" 317809-D-R-H 23.5 (10.7) • 76.1 mm L GLR300G GXG 1 1/4" 317809-D-L-B-H 31.0 (14.1) 76.1 mm L NONE GXG 1 1/4" 317809-D-L-H 23.5 (10.7) NOV 2018 GFV-120 Page 4 of 11 TABLE E: 3" MODEL UMC ASSEMBLY CONFIGURATIONS • APPROXIMATE UMC BODY MODEL UTD CONTROL SHIPPING SIZE ASSEMBLY R-RIGHT VALVE END TEST AND PART NUMBER WEIGHTS L-LEFT CONNECTIONS DRAIN SIZE LBS. (kg) 3" R GLR300G GXG 1 1/4" 317812-R-B-H 59.0 (26.8) 3" R NONE GXG 11/4" 317812-R-H 35.4 (16.1) 3" L GLR300G GXG 1 1/4" 317812-L-B-H 59.0 (26.8) 3" L NONE GXG 1 1/4" 317812-L-H 35.4 (16.1) TABLE F: 4" MODEL UMC ASSEMBLY CONFIGURATIONS ASSEMBLY APPROXIMATE UMC BODY MODEL UTD CONTROL SHIPPING SIZE R-RIGHT VALVE END TEST AND PART NUMBER WEIGHTS L-LEFT CONNECTIONS DRAIN SIZE LBS. (kg) 4" R GLR300G GXG 2" 317817-R-B 87.5 (39.7) 4" R NONE GXG 2" 317817-R 58.9 (26.7) 4" L GLR300G GXG 2" 317817-L-B 87.5 (39.7) 4" L NONE GXG 2" 317817-L 58.9 (26.7) TABLE G: 6" (DN150) / 165.1 MM MODEL UMC ASSEMBLY CONFIGURATIONS • ASSEMBLY UMC BODY MODEL UTD APPROXIMATE SIZE CONTROL END TEST AND PART NUMBER SHIPPING R-RIGHT VALVE CONNECTIONS DRAIN SIZE WEIGHTS L-LEFT LBS. (kg) 6" R GLR300G GXG 2" 317818-R-B 124.5 (56.5) 6" R NONE GXG 2" 317818-R 80.0 (36.3) 6" L GLR300G GXG 2" 317818-LB 124.5 (56.5) 6" L NONE GXG 2" 317818-L 80.0 (36.3) 165.1 mm R GLR300G GXG 2" 317818-D-R-B 124.5 (56.5) 165.1 mm R NONE GXG 2" 317818-D-R 80.0 (36.3) 165.1 mm L GLR300G GXG 2" 317818-D-L-B 124.5 (56.5) 165.1 mm L NONE GXG 2" 317818-D-L 80.0 (36.3) TABLE H: 8" MODEL UMC ASSEMBLY CONFIGURATIONS ASSEMBLY UMC BODY MODEL UTD APPROXIMATE SIZE CONTROL END TEST AND PART NUMBER WEIGHTS R-RIGHT VALVE CONNECTIONS DRAIN SIZE LBS. (kg) L-LEFT 8" R GLR300G GXG 2" 317890-R-B 177.8 (80.6) 8" R NONE GXG 2" 317890-R 115.7 (52.5) • NOV 2018 GFV-120 Page 5 of 11 FLOW RATE-LPM 200 300 400 500 600 700800 1000 2000 3000 5000 7000 10000 7.00- - - 6.00 •_. 0.40 5.00 0.30 4.00 _.. ry 03 a 3.00 ti =° . - 0.20 O CO COCO (f) O ^� � 0 J O I LLJ Lu CC 2.00 . CC U) D, oo co co N y0 o p'� 0.10 LU a O2 ^�Oto 0.08 1.00 4 , 0.07 0.90 + t_.. 0.06 0.80 a 0 0.70 .05 0.60 0.04 0.50 :..... _.. 40 50 60 70 80 90100 200 300 400 500 600 800 1000 2000 3000 4000 FLOW RATE-GPM UMC Equivalent Length of Piping for Friction Losses Through Schedule 40 Pipe • 11/4" =6 feet • 2'/2" = 14 feet • 6" =30 feet • 11/2' =9 feet • 3" = 11 feet • 8" =23 feet • 2" = 8 feet • 4" = 14 feet FIGURE 3: MODEL UMC MANIFOLD CHECK (WITHOUT BFV) FRICTION LOSS CURVES 11/4" TO 8" 4111 FLOW RATE-LPM 200 300 400 500 600 700800 1000 2000 3000 5000 7000 10000 7.00 - - -- - - ---- ---. -- -- --- 6.00 _... .. _ _.... 0.40 5.00 0.30 4.00 CC (A < Q El- 3.00 \\n �o oh 0.20 CO u) p2 0 U) co 200 ,NN, O cc D O2 U) P 00 O ry00 (n W O2 O 0.10 (I) 0_ "'p2 0.09 a 0.08 0 1.00 .07 0.90 ..... .. 0.06 0.80 . 0.05 0.70 0.60 _ .. ... .. 0.04 0.50 _... _... _. 40 50 60 70 80 90100 200 300 400 500 600 800 1000 2000 3000 4000 FLOW RATE-GPM UMC Equivalent Length of Piping for Friction Losses Through Schedule 40 Pipe • 11/4' =8 feet • 21/2' =22 feet • 6" =38 feet • 11/2" = 11 feet • 3" = 17.5 feet • 8" =27 feet • 2" = 12 feet • 4" = 18.5 feet III FIGURE 4: MODEL UMC MANIFOLD CHECK (WITH BFV) ASSEMBLY FRICTION LOSS CURVES 11/4" TO 8" NOV 2018 GFV-120 Page 6 of 11 TABLE I: MODEL UMC AND BUTTERFLY VALVE END TO END DIMENSIONS • End to End Dimension With- End to End Dimension With Globe Butterfly Control Valve Size out Butterfly Control Valve Globe Butterfly Control Valve End to End Dimension inches (mm) inches (mm) inches (mm) 1 1/4" 10.75 12.89 2.64 MT x FT (273) (327) (67.9) 1 1/4" 11.4 15.4 4 G x G (290) (391) (101.6) 1 1/2" 10.75 13.12 2.87 MT x FT (273) (333) (73) 1 1/2" 11.4 15.5 4.1 G x G (290) (394) (104) 2" 10 14.49 4.49 G x G (254) (368) (114) 2 1/2" 10.63 15.12 4.49 G x G (270) (384) (114) 65 mm 10.63 15.12 4.49 G x G (270) (384) (114) 3" 12.75 16.55 3.8 G x G (324) (420) (96.4) 4" 14.63 19.13 4.5 G x G (371) (486) (115.4) 6" 17.44 22.64 5.2 G x G (443) (575) (132.4) 150 mm 17.44 22.64 5.2 G x G (443) (575) (132.4) 8" 24.0 30.0 5.8 G x G (609.6) (762) (147.3) .icift4. Ill I ....,,,... /' ;.. s ty. will IHA,1% DIN1 loO-` ,, 1 , \'. Icl I.A ,7 014_0 JMT I Ol ' ••��� �, ��'VT ' i ' j" II ILII ! _.c.j. ii me., ■ �Ilii��Q ' I VIM: A B D G B C E A C D G E A B C D E F G H 1 SIZE Inches Inches Inches Inches Inches Inches Inches Inches Inches (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) 1 1/4"TXT 3.1 6.2 8.4 6 6.7 13 2 10.7 9.5 (79) (157) (214) (150) (170) (328) (50) (272) (241) 1 1/4"GXG 3.1 6.2 8.4 6 6.7 11.9 2 11.4 (79) (157) (214) (150) (170) (301) (50) (290) 1 1/2"TXT 3.1 6.2 8.4 6 6.7 13 2 10.7 9.5 (79) (157) (214) (150) (170) (328) (50) (272) (241) 1 1/2"GXG 3.1 6.2 8.4 6 6.7 11.9 2 11.4 - (79) (157) (214) (150) (170) (301) (50) (290) 2" 3.9 5.4 7.6 6 6.8 11.9 2.1 10 _ (99) (136) (193) (150) (173) (301) (53) (254) 2 1/2" 3.3 6.7 9.2 6.2 7.2 12.3 2.3 10.6 - (84) (171) (233) (157) (182) (312) (58) (269) • 76.1 mm 3.3 6.7 9.2 6.2 7.2 12.3 2.3 10.6 (84) (171) (233) (157) (182) (312) (58) (269) FIGURE 5: MODEL UMC ASSEMBLY WITHOUT BFV DIMENSIONAL DRAWING FOR SIZES 1 1/4" TO 2 1/2" NOV 2018 GFV-120 Page 7 of 11 to ' • (oliziaTI,1, in, . • 4,._,„..,t,,,, 0 6 111 Ifi -r — t ti [4iIa . 11wI4 1 _ slim sue c���;iTi' ' 1 q �; rlii►i --- �i ` I' -' 1 -j* B I- r-H 1 I- A H C _ D - E G A B C D E F G H SIZE inches inches inches inches inches inches inches inches (mm) . (mm) (mm) (mm) (mm) (mm) (mm) (mm) 3„ 6.5 6.9 9.4 _ 6.4 16 2.4 12.7 (165) (176) (238) (161) (406) (61) (324) 4„ 7 8.3 11.2 5.6 7 17.7 3 14.6 (177) (210) (284) (143) (178) (449) (76) (371) 6" 8 9.5 12.4 6.4 7.9 19.9 3.9 17.5 (203) (241) (315) (163) (201) (504) (99) (444) 165.1 mm 8 9.5 12.4 6.4 7.9 19.9 3.9 17.5 (203) (241) (315) (163) (201) (504) (99) (444) 8" 9 15 1 8 2 22.3 2 24 0 (229) (292) (36868) (203) (229) (566) (127) (609.6) FIGURE 6: MODEL UMC ASSEMBLY WITHOUT BFV DIMENSIONAL DRAWING FOR SIZES 3" TO 8" 0 NOV 2018 GFV-120 Page 8 of 11 FLOW SWITCH REQUIREMENTS The Model UMC Floor Control/ Shotgun Riser assembly is in the replacement parts section of the technical literature. • sold inclusive of a Potter VSR flow switch. The flow switch The Potter VSR Flow switch includes 2 sets of switches, utilizes exactly the same electrical and switch components one set can be used to activate the central fire alarm system as the Potter VSR flow switch but includes an adapter which while the other set can be utilized to activate a local alarm (if attaches directly to the Model UMC Manifold Check as- necessary). See figure 7 for a typical wiring diagram for the sembly. This adapter has been tested as part of the UMC Model VSR Flow switch. assembly to ensure the hydrostatic strength as well as the placement and sensitivity of the paddle is within the criteria Note:For more information on the flow switch see www.pottersignaf.com. set forth by UL and FM. The part number for the flow switch assembly can be found WIRE NUT LOCAL WIRE NUT FIRE PANEL OR AUDIBLENISUAL ADDRESSABLE ANNUNCIATOR MODULE NEUTRAL F(y WHITE WHITE Z BLACK (,+,� �Ya) Um BLACK (LINE/HOT) -0 O- �m�z i a°5o o / < U U INV VP _ ll aviono!! -- - 1 ,,,Cr„ 1 1 III sl°'` 7.-,---, ©� ri—ul( f_io mum.,„„„„„„„„„,h _, - FIGURE 7: MODEL VSR-M FLOW SWITCH TYPICAL WIRING DIAGRAM RED — RED V S-1 FIRE ALARM COMMON WHITE) I I COMMON WHITE CONTROL PANEL ” ft END OF LINE SUPERVISORY YELLOW /\ YELLOW RESISTOR CIRCUIT I o I GREEN 1 OPERATORCASE CONTACT RATINGS: GROUND 16A 125V/250 VAC GEAR OPERATORS ORANGE I S—c27 COMMON (BLACK) ��/// BLUE VOLTAGE I — I AUX. DEVICE SOURCE (BELL/HORN) VALVE WIRING SHOWN WITH VALVE IN OPEN POSITION III FIGURE 8:TYPICAL BUTTERFLY VALVE WIRING DIAGRAM NOV 2018 GFV-120 Page 9 of 11 INSTALLATION AND MAINTENANCE INSTALLATION Note:A main drain test may also operate local fire alarms unless they are tem- porarily disabled. • The Model UMC Floor Control/ Shotgun Riser assembly is sold as a complete unit, assembled and shipped in a single MAINTENANCE box. The Model UMC Manifold Check Valve must be installed in The owner is responsible for the Inspection, Testing and an accessible and visible location, which is maintained at Maintenance of their fire protection system. or above a minimum temperature of 40°F (4°C). The UMC System inspection, testing and maintenance shall be per- may be installed in the horizontal or vertical (flow upward) formed in accordance with this section as well as NFPA 25 orientation. or other applicable Standard to insure the integrity of the All valves must be installed in accordance with the appropri- entire system, including alarm functions as well as other ate installation standard (i.e. NFPA 13 or other). All electri- coscomponents.Any impairments must be immediately cal connections must be made per the applicable installation corrrem ected. standard and/or the National Electric Code (i.e. NFPA 70, Before closing a system main control valve for maintenance NFPA 72 or other). work on the fire protection system, obtain permission to shut Proper hydrostatic test procedure must be followed per down the affected fire protection system from the proper au- NFPA 13. thorities and notify all personnel who may be affected. Note: It is not necessary to remove the ARV Relief Valve Note: prior to system hydrostatic test. The Adjustable ARV may All valves should be carefully inspected,tested,and maintained in accordance simply be temporarily adjusted to a pressure above the with NFPA 25 or other applicable Standard. test pressure during the hydrostatic test. Be sure to re- It is important to ensure a clean water supply free of debris turn the ARV Relief Valve to it's normal setting after the and solid particles such as sand, gravel, or mud. completion of the hydrostatic test. If, during an inspection of a water control valve, sediment or free particles ofmatter are noted, a further examination of MODEL ARV RELIEF VALVE internal valve parts is necessary. SETTING PROCEDURE All deposits should be removed from all operating parts and ports. The Globe 1/2 inch Model ARV, 300 psi Adjustable Pressure Where difficulty in performance is experienced, the manu- Relief Valve, is factory set to relieve at a pressure of ap- facturer or its authorized representative shall be contacted proximately 175 psi (12 bar). before any field adjustment is to be made. The Pressure Relief Valve may be reset to a higher Pres- UMC Clapper Facing.The rubber clapper facing should be sure; however, it must be reset to relieve at a pressure checked for wear or damage and to determine that it is free • which is in accordance with the requirements of the author- of dirt and other foreign substances. If found to be worn or ity having jurisdiction,typically nominal 10 psi (.7 bar)above damaged (e.g., foreign matter embedded in the surface; cut the expected normal system pressure. or torn facing), the facing should be replaced. If it is dirty, To reset the Model ARV pressure relief valve, use an ad- it should be cleaned. Compounds which could damage the justable crescent wrench, to turn the hex cap clockwise for rubber facing must never be used. Should clapper facing a higher pressure setting or counter-clockwise for a lower replacement become necessary, the following steps should pressure setting. Use the calibrated lines on the stem for be performed; an approximate relief pressure setting. 1 full turn of the hex Note:Before performing the following steps, insure that the system has been cap will result in approximately 25 psi increase or decrease. depressurized and drained. To verify the new setting, isolate the Model ARV relief valve Clapper Removal and use a small hydrostatic pump attached to the supply. Increase the pressure at the relief valve to 10 psi above STEP 1. Remove handhole cover. the expected normal system pressure. Readjust the ARV STEP 2. Remove hinge pin plugs from front and back of as needed to maintain a 10 psi higher relief setting. UMC. TESTING STEP 3. Using alien wrench, push hinge pin from back of UMC towards front. Reference NFPA 25, Standard for the Inspection, Testing STEP 4. Once hinge pin is accessible,carefully grab with and Maintenance of Water-Based Fire Protection Systems. pliers or similar to pull hinge pin out of body. Before proceeding with any tests involving water flow, the Note:Care must be taken to confine clapper spring while extracting hinge pin following precautions need to be taken: from body.Spring is under tension around hinge pin. It is also recommended STEP 1. Check the location where the test connection to cover drain port to minimize the possibility of spring inadvertently dropping discharges to make sure that all is clear and into drain piping. that there is no possibility of the water flow STEP 5. Carefully remove clapper assembly from UMC. causing damage or injury. Clapper Replacement. When replacing clapper, be sure STEP 2. Check the end of the test connection to make clapper spring has been properly positioned around hinge sure that it is unobstructed. To achieve a satis- pin such that tension is applied to the clapper by the spring. factory test, there must be an unrestricted flow Seat Ring. The seat ring should be checked for nicks and of water when the test valve is wide open. for stones, dirt or other foreign matter. It should be cleaned STEP 3. Check for alarm connections to a central sta- thoroughly. If the seat ring is found to be damaged, UMC • tion or fire department. If such connections are should be replaced. found, give proper notice to the signal receiving station before proceeding with the test. NOV 2018 GFV-120 Page 10 of 11 Water Flow Switch (VSR-M). There is no maintenance re- quired, only periodic testing and inspection. Should switch MODEL ARV RELIEF VALVE be found to be malfunctioning, refer to Potter Signal Techni- (SEE GFV-575 for more information) cal Literature for guidance. • Specify: MODEL ARV 1/2"ADJ RELIEF VALVE PN. Model ARV Adjustable Relief Valve. Valve is not field ser- 317900 viceable. If inadvertent leakage is observed, first test the Note: pressure setting utilizing the procedure outlined in the ARV 300 psi(20.6 Bars)Pressure Gauges Standard(600 psi(41.2 Bars) Ordered Relief Valve Setting Procedure. If valve does not respond to Separately field adjustments, valve shall be replaced. Note: PN 300121-D Visual calibration lines on valve are used for approximate adjustment. Verify GLOBE® PRODUCT WARRANTY pressure setting with pressure gauge. Model UTD Universal Test & Drain Valve: The Globe Globe agrees to repair or replace any of its manufactured Model UTD Universal Test and Drain Valve does not require products workmanship a period of one year from date of shipment.any regularly scheduled maintenance. The UTD is not field serviceable. Model ARV Care and Maintenance For specific details of our warranty please refer to Price List Terms and Conditions of Sale (Our Price List). ORDERING INFORMATION MODEL UMC UNIVERSAL MANIFOLD CHECK VALVE ASSEMBLY Specify: MODEL UMC MANIFOLD CHECK VALVE ASSEMBLY,SIZE (1 1/4", 1 1/2", 2", 2 1/2", 76.1 mm, 3", 4", 6", 165.1 mm, 8") PN (see Part Number in Table A-G) REPLACEMENT PARTS MODEL UMC UNIVERSAL MANIFOLD CHECK VALVE REPLACEMENT PARTS/KITS VSR-M FLOW SWITCH with ADAPTER(includes gasket) SIZE PART NUMBER • 1 1/4" -2" 91144802-A-G 2 1/2" 91144825-A-G 3" 91144803-A-G 4" 91144804-A-G 6" 91144806-A-G 8" 91144808-A-G MODEL UTD TEST AND DRAIN (SEE GFV-570 for more information) Specify: MODEL UTD TEST AND DRAIN WITH RELIEF VALVE,SIZE (1", 1 1/4", or 2") PN: SIZE PART NUMBER 1" (DN25) 311729 1 1/4"(DN32) 311730 2" (DN50) 311731 Specify: MODEL UTD TEST AND DRAIN,SIZE (1", 1 1/4", or 2") PN: SIZE PART NUMBER 1"(DN25) 311704 1 1/4"(DN32) 312368 2"(DN50) 311708 4077 Airpark Dr. Technical Support Standish. MI 48658 1-800-248-0278 www.globesprinkler.com ,;; Ph. 989-846-4583 techserviceglobesprinkler.com NOV 2018 GFV-120 Page 11 of 11 FireLock NXTTM Dry Valve ,ctauiic Series 768 30.80 • xy i Patent Pending Certifications/Listings: c us FM LPCB (4 Fd—S) 104f/01 0832 MEA:248-98-E See Victaulic Publication 10.01 for more details. Product Description: The patent-pending Victaulic Series 768 FireLock NXT Dry Valve is a low differential, latched clapper valve that uses a unique direct acting diaphragm to separate system water supplies from dry-pipe sprinkler systems. see page 12 for European trim • Job/Owner Engineer System No. j Spec Section Location Paragraph Contractor Approved Submitted By j Date Date • victautic.com I NXT Dry Valve I Series 768 I Publication 30.80 30.80 4219 Rev G Updated 01/2015 ©2015 Victaulic Company.All rights reserved. 1 jictaulic° victaulic.com I NXT Dry Valve I Series 768 I Publication 30.80 Features: The low differential, unique latch and actuator design of • the valve allows the valve to be reset without opening the valve. The low differential design is not subject to water columns.The valve allows the water to operate a water motor alarm and/or electric pressure alarms,which Capper :, continue until the flow of water stops. With the optional q(At �� Latchaccelerator,the valve can be configured to respond Vit° i,, k4, faster for use in larger systems, or where faster response times are required. __ 1 �`,� Diaphragm The valve is rated to 300 psi/2065 kPa water working ®N s.7.21� r4 if••• Assemby �;� pressure and is factory tested hydrostatically to 600 psi/ 1y11? ��f 4135 kPa for sizes 1 1/2—8'/4O—200 mm.VdS trim ,...r Clapper Seal configurations are approved to 16 BAR (see page 12). 0 IF 0 Required air pressure for all trim variations is 13 psi/ ' Seat 90 kPa.The Series 768 is available grooved x grooved. Exaggerated for clarity Standard grooved dimensions conform to ANSI/AWWA C6O6. Note:Valve is shown in the"set"position The Victaulic Series 768 FireLock NXT Dry Valve is made of high-strength, low-weight ductile iron, and it offers easy access to all internal parts. All internal parts are replaceable. Maintenance and service can be performed without removing the valve from its installed position. The rubber clapper seal is replaced easily without removing the clapper from the valve.The valve is painted inside and out to increase corrosion resistance. The body is tapped for main drain and all available trim configurations. 4111 Installation Options The Victaulic Series 768 FireLock NXT Dry Valve is available bare, or in the following configurations: Pre-trimmed The pre-trimmed valve comes completely assembled with all necessary trim components. Vic-Quick Riser The Vic-Quick Riser comes completely pre-trimmed and includes a shut off valve(uses a Series 705W FireLock Butterfly valve—request publication 10.18;for 1 V2 and 274O and 50 mm sizes, the Vic-Quick Riser comes with a Series 728 Ball Valve—request publication 10.17)for system shut off, pre-set pressure switches, and a drain kit for ease of installation. For complete Vic-Quick Riser information request publication 30.20. Series 745 FireLock Fire-Pac (Available in North America only) The Fire-Pac is a completely pre-assembled fire protection valve that provides maximum service in a minimal enclosed space. The unit includes a water supply shutoff valve, the sprinkler system fire protection valve, alarm line pressure switches, air supervisory pressure switches, supervisory pump switches, and digital pressure gauges that are easily viewed through a window in the cabinet door. For complete Fire-Pac information request publication • 30.23. Optional accessories ship separately. 30.80 4219 Rev G Updated 01/2015 CO 2015 Victaulic Company.All rights reserved. victaulic.com 2 ictaulic" victaulic.com I NXT Dry Valve I Series 768 I Publication 30.80 Dimensions: The 4 Inch/114.3 Mm UI Listed,FM Approved Configuration Is Shown Below 1'h-2'/48.3-60.3 mm Configurations Contain 3/4"/19 mm Drain Valves. 2 V2-3773.0-88.9 mm Configurations Contain 1 1/4"131 mm Drain Valves. • 4-8"/114.3-219.1 mm Configurations Contain 2750 mm Drain Valves. r1 11 A A r I I F--4 _4 F--'� rr-T 1 1 _vi. _-1r -111 ��Inii-a 1 II n ��\J� 1: -1' F II a I1 I ,:;.!..0A F - �". �� I� J.L� _ - A A „Lill �� �11F 1 I D 'DI 11111111111i,- li tiliK) li NI ‘r.nilit 1 Falb I: 1 /1 lila 91 . J fir � �.•.���I.. igno i 1 .� ' ,t4.-,.+"Wilk i A 8 111 � kailiti IF. , *A1 16 liV i 1 I, r''-'1 L IQ I I, _I :(W.14'),��_ _ ' LL-1' ii 1. J caT� NNW SOF Mb MIMI H 14- K C *E, > • Full Open 1 Approx. Weight Dimensions Each Actual r ! I ; _ i Nominal Outside I 1 I Without With Size Diameter A Al B 1 B1 C D Dl E ' El j F !HIP! .1 1 K Trim Trim inches inches inches inches inches linches inches inches inches inches inches linches inches inches inches1 inches lbs. lbs. mm mm mm mm mm mm mm mm mm mm mm mm ' mm ,i- mm 1 mm mm II kg kg 1'h 1.900 ; 9.00 16.35 27.25 39.50 13.75 16.00 - 5.25 8.50 9.50 121.25 ' 3.04 1 9.17 6.98 16.7 43.0 40 483 1228.60 415.29 692 1003 349 ! 406 133 215 241 539 77.21 12.32.91 177.29 7.6 19.5 2 2.375 9.00 1337 2725 3950 13.75 : 16.00 _ 5.25 850 950 2125 3.04 9.17 6.98 17.0 43.0 50 60.3 228.60 339.60 692 1003 349 406 133 215 241 539 77.21 232.91,177.29 7.7 19.5 2Y2 2.875 12.61 16.50 32.25 144.25. 13.50 1 16.00 17.50 5.25 9.00 9.25 1 21.25 1 3.90 10.50 6.93 41.0 65.0 65 73.0 32029 419.10 819 1123 342 406 444 133 228 , 234 ' 539 99.06 266.70 176.02' 18.7 29.5 3.000 12.61 16.50 32.25 '44.25 13.50 .50 5.2 •.*" 9.25 21.25 3.90 10.50 6.93 41.0 76.1 mm ''�� , '� 76.1 320.29 419.10 819 1123 342 406 444 133 228 234 539 99.06 266.70,176.02 18.7 295 5.25 9.00 9.25 21.25 3.90 10.50 1 6.93 41.0 65.0 80 88.9 320.29'419.10 819 1123 342 406 444 133 I 228 234 539 99.06 1266.701176.02 18.7 29.5 ', 12.6116.50 32.2513.50 16.00 17.50 4 4.500 15.03 19.83 3350 45.50 15.00 15.75 2050 525 9.00 10.75 21.001 6.25 1 9.62-1-8A6 ' 59.0 95.0 100 114.3 381.76 503.68 850 1155 381 400 ( 520 133 228 273 533 158.75 244.34 214.881 26.7 43.0 165.1 mm 6.500 16.00 22.00 34.00 46.00 15.50' 17.00 22.001 525 850 ' 1150 20.50 6.20 9.62 1 8.84 1 80.0 116.0 165.1 406.40 558.80 863 1168 393 431 558 133 215 292 520 157.48 i 244.34'224.53! 36.2 52.6 _ j 6 6.625 16.00 22.05 34.00 46.00 1530 17.00 22.00 5.25 8.50 1130 20.50 6.20 i 9.62 8.84 80.0 116.0 150 1683 406.40 560.07 863 1168 393 431558 I 133 215 292 520 157.48 24434 224.53. 36.2 52.6 L8 8.625 17.50123.00 3350 4530 16.75 20.00 125.25 6.25 8.75 12.75 1850 6.05 9.40 110.21 1 122.0 158.0 200 1 219.1 1444.501584.20 850 1155 425 508 1 641 1 158 2221 323 ` 469 1153.67 238.761259.33 55.3 1 71.6 NOTES: The"A"dimension coupling is not shown in order to clarify dimensional callouts. Components shown as dotted lines denote optional equipment. *Measurements denoted with an asterisk take optional equipment into account. Optional drain connection kit is shown for reference and takeout dimensions. - • 30.80 4219 Rev G Updated 01/2015 ©2015 Victaulic Company.All rights reserved. victaulic.com 3 •ctaulic victaulic.com I NXT Dry Valve I Series 768 I Publication 30.80 Performance: • Hydraulic Friction Loss The chart below expresses the flow of water at 65°F/18°C through a full open valve. 6.0 . ...... .. .... 5.0 4.0 3.0 0e sF ,Fs 2.0 a1 N v o F d Re h� �.... o� ��F � 00- ,.0 ce 0.8 p p 0.8 0.7 ce 0.6 0.5 N 0.4 a 0.3 0.2 0.1 10 20 30 40 60 80 100 200 300 400 600 1,000 2,000 4,000 6,000 10,000 20,000 800 3,000 8,000 FLOW RATE-GPM Frictional Resistance The chart below expresses the frictional resistance of Victaulic Series 768 FireLock NXT. Dry Valve in equivalent feet of straight pipe. Actual Equivalent Nominal Outside Length of Size Diameter Pipe inches inches feet mm mm meters 11/2 1.900 3.00 40 483 0.914 J 2 2375 9.00 50 , 60.3 2.743 21/2 ! 2.875 8.00 65 i 73.0 2.438 3.000 8.00 76.1 mm 76.1 2.439 3 3.500 17.00 80 88.9 I 5.182 4 4.500 21.00 100 1143 6.401 6.500 22.00 165.1 mm 165.1 6.706 6 6.625 22.00 150 168.3 6.706 8 8.625 50.00 1 200 219.1 15.240 __ I • 30.80 4219 Rev G Updated 01/2015 0 2015 Victaulic Company.All rights reserved. victaulic.com 4 jetaulia victaulic.com I NXT Dry Valve I Series 768 I Publication 30.80 ;Values: Operation: C„values for flow of water at+60°F/+16°C through a fully The Series 768 Dry Valve contains a clapper, which has • open valve are shown in the table below. a replaceable rubber seal.The clapper makes contact with the valve's seat ring,which has access Formulas for Cv values where: holes leading into an intermediate chamber in the valve. AP=Q2/C,2 I Flow Coefficient ' c The diaphragm contacts the latch, and the latch holds Q=c,x VAP Q(Flow) GPM the clapper closed. AP(Pressure Drop) I psi In the closed position,the valve diaphragm is maintained in the extended position by the water supply pressure from upstream of the water supply control valve. The I I i diaphragm latch holds the clapper in the closed position. The Series 776 Low Pressure Actuator(LPA) maintains Valve Size I Full Open the water, and the system's air pressure controls the Actual I LPA. Required air pressure is 13 psi/90 kPa. The design Nominal Outside of the 776 actuator does not require the traditional air Size ' Diameter Flow Coefficient ( cushion of 10–20 psi/69–138 kPa. Excess air inches inches K pressure above 13 psi/90 kPa will cause a delay in valve mm mm K� If 1'h 1.900 60 ( operation. __ 40 50 Once the system's air pressure reduces to the trip point, 2 2.375 111 0 5the LPA opens and allows the water supply pressure in 20 2.8758180 the diaphragm to release(i.e. an open sprinkler). This 6s 3 156.0 release allows the latch to move to its open position, �— — 3.000 180 j permitting the clapper to pivot freely, thus allowing water I76.1 mm I 76 .1 _ j 156.0 I- f into the system. 3 � 3.500 �� 200 80 1 88.9 173.0 Water enters the intermediate chamber of the valve — — 1 4 ! 4.500 350 through the holes in the seat ring. The water flows from 100 1143 302.8 the intermediate chamber to the alarm line,which 165.1 mm 6.500 1� F activates the system's alarms. The alarms continue to 165.1 865.0 6 6.625 1000 sound until the flow of water stops. III 150 1683 ( 865.0 When the flow of water stops,the spring-assisted valve 28 8.6 521 ; 149 00 clapper returns to the closed position. The valve acts as an alarm check valve until the system is back in service as a dry system, according to the proper procedure. „,--_ • 30.80 4219 Rev G Updated 01/2015 0 2015 Victaulic Company.All rights reserved. victaulic.com 5 ictaulic` victaulic.com I NXT Dry Valve I Series 768 I Publication 30.80 Material Specifications: • Body: Ductile iron conforming to ASTM A-536, grade 65-45-12. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Clapper: Aluminum bronze UNS-C95500 Latch: Aluminum bronze UNS-C95500 Shaft: Stainless 17-4 Clapper Seal: Peroxide cured EPDM, ASTM D2000 Bushings/Seat 0-rings: Nitrile Springs: Stainless Steel (300 Series) Diaphragm: Peroxide cured EPDM with fabric reinforcement Bill of Materials 1 Valve Body 12 Cover Plate 2 Clapper 13 Cover Plate Gasket 3 Clapper Seal 14 Cover Plate Bolts* 4 Seal Ring 15 Latch 5 Seal Washer 16 Latch Spring 6 Seal Retaining Ring 17 Latch Spring Bushing and 0-ring(Qty.2) 7 Seal Assembly Bolt 18 Diaphragm • 8 Bolt Seal 19 Diaphragm Cover 9 Clapper Spring 20 Diaphragm Cover Cap Screws(Qty.8) 10 Clapper Shaft 21 Latch Shaft 11 Clapper Shaft Bushing and 0-ring(Qty.2) r ® • 01 �fiC • I - rC. • 0 •ro ` o ° %.11 �1, o o CO am% • ® mac•• - O NOTE:The 11/-inch/48.3-mm and 2-inch/60.3-mm valve sizes contain washers under the heads of the cover plate bolts. 30.80 4219 Rev G Updated 01/2015 O 2015 Victaulic Company.All rights reserved. victaulic.com 6 \A-fauna a victaulic.com I NXT Dry Valve I Series 768 I Publication 30.80 Trim Package Details: • Air Compressor(See page 8 for more on the Victaulic Series 7C7 Compressor Package) Trim Packages: • • NOTE: See page 11 for details of trim and page 12 for Air Maintenance Trim Assembly details of European trim. • Alarm Panels 1 Galvanized components. • Drain Connection Kit 2 Series 776 Low-Pressure Actuator—The Series 776 Low-Pressure Actuator is pneumatically actuated and requires only 13 psi/90 kPa minimum air Air Supply Requirements: pressure, regardless of the system supply pressure. This actuator allows the system to operate with a low The required air pressure for Series 768 FireLock NXT air or gas pressure of 7 psi/48 kPa. Dry Valves is 13 psi/90 kPa minimum, regardless of the system supply water pressure. Air pressures should be 3 All Required Pipe and Fittings. kept below 18 psi/124 kPa, unless a Series 746-LPA 4 All Standard Trim Accessories. Dry Accelerator is installed. Systems with air pressures higher than 18 psi/124 kPa may require the addition of a 5 All Required Gauges Series 746-LPA Dry Accelerator. Optional Trim Package: If multiple Series 768 FireLock NXT Dry Valves are 1 Black Trim for Foam Systems—If the valve is installed with a common air supply, isolate the systems intended for use in a foam system, black trim must with a spring-loaded, soft-seated ball check valve to be ordered, per NFPA requirements. Specify this ensure air integrity for each system. Good practice is requirement on the order. to include a ball valve for isolation and service of each individual system. The engineer/system designer is responsible for sizing Optional Accessories: the compressor so that the entire system is charged to • Series 746-LPA Dry Accelerator—The Series the required air pressure within 30 minutes. DO NOT 746-LPA Dry Accelerator is required when the oversize the compressor to provide more airflow. An Series 768 Dry Valve is installed in large systems to oversized compressor will slow down or possibly prevent improve response time. Request submittal 30.64. valve operation. • • Series 760 Water Motor Alarm—The Series 760 If the compressor fills the system too fast, it may be Water Motor Alarm is a mechanical device that necessary to restrict the air supply. Restricting the air sounds when a sustained flow of water occurs(such supply will ensure that air being exhausted from an open as with an open sprinkler). Request submittal 30.32. sprinkler or manual release valve is not replaced by the air supply system as fast as it is being exhausted. • Series 75B Supplemental Alarm Device—The Series 75B Supplemental Alarm Device is designed to provide a continuous alarm for systems equipped with a mechanical device. Request submittal 30.33. • Series 75D Water Column Kit—The Series 75D Water Column Kit is designed to minimize residual water in the riser from collecting above the clapper. Request submittal 30 34. • Alarm Pressure Switch—Alarm Pressure-Switches are designed to activate electrical alarms and control panels when a sustained flow of water occurs (such as with an open sprinkler). • Air Supervisory Pressure Switch—Air Pressure Supervisory Switches are used to monitor low system air pressure and are factory pre-set. • Air Supply System—The air supply system contains all components for establishing and maintaining air in the system.The compressor, low-pressure alarms, ball valves, and required trim are included in the air supply system. — — --- — — • 30.80 4219 Rev G Updated 01/2015 ®2015 Victaulic Company.All rights reserved. victaulic.com 7ictaulic victaulic.com I NXT Dry Valve I Series 768 I Publication 30.80 Compressor Sizing: • COMPRESSOR REQUIREMENTS 12 _.�... .. 20 psi/138 kPa 13 psi/90 kPa 10 W K ♦f 00 O 6 _._. .° 0,9 LL ♦ W ♦ K 650 7 ♦ 150 .00 2 ♦•0 ♦ 0 0 0 o SYSTEM CAPACITY(in gallons) Base or Riser-Mounted Compressors: Shop Air or Tank-Mounted Air Compressors: 411 For base or riser-mounted compressors, the recom- In the event a compressor becomes inoperative, a mended air pressure of 13 psi/90 kPa is the "on" or properly sized tank-mounted air compressor provides "low" pressure setting for the compressor. The "off" the greatest protection for systems. or "high" pressure setting should be 18 psi/124 kPa. When shop air or a tank-mounted air compressor is Victaulic offers the Series 7C7 Compressor package used, the Series 757 Regulated AMTA must be installed. for FireLock NXT devices which is riser-mounted and The Series 757 Regulated AMTA provides proper air pre-set for the FireLock NXT pressure requirements as regulation from the air reservoir to the sprinkler system. stated above. For information on the Series 7C7 package, consult publication 30.22. The Series 7C7 For tank-mounted air compressors, the recommended Compressor package is only available in North America. air pressure of 13 psi/90 kPa should be used as the set point for the air regulator. The "on" pressure of the When a base or riser-mounted air compressor supplies compressor should be at least 5 psi/34 kPa above the air to a Series 768 FireLock NXT Dry Valve, it is not set point of the air regulator. necessary to install the Victaulic Series 757 Regulated Air Maintenance Trim Assembly(AMTA). In this case, the airline of the compressor connects to the trim at the fitting where the Series 757 Regulated AMTA is normally installed (refer to the applicable trim drawing). If the compressor is not equipped with a pressure switch, the Series 757P Air Maintenance Trim Assembly with Pressure Switch should be installed. For information on the Series 757 Regulated Air Maintenance Trim Assembly, see publication 30.35. For information on the Series 757P Air Maintenance Trim Assembly, see publication 30.36. 30.80 4219 Rev G Updated 01/2015 ©2015 Victaulic Company.All rights reserved. victaulic.com 8 xictaulia victaulic.com I NXT Dry Valve I Series 768 I Publication 30.80 Series 757 Regulated Air � M71DE Maintenance Trim Assembly: • Victaulic recommends a maximum of two III Series 768 FireLock NXT Dry Valves per Series 757 Regulated AMTA Bill of Materials 1 1/2"/3.2 mm Restrictor 2 Slow Fill Ball Valve(Normally Open) 3 Air Regulator ".**4 ..• 4 Strainer(100 Mesh) ,' 5 Spring-Loaded,Soft-Seated ''✓1� o Ball Check Valve 0 6 Fast Fill Ball Valve(Normally Closed) 0,..„,,...::iii ji .. 4 0 til Alk. t1 Exaggerated for clarity Series 757P Air Maintenance Trim �� , E fi.e Assembly With Pressure Switch: I •g ,, r p • Victaulic recommends a maximum of two Series 768 FireLock NXT Dry Valves per Series Ill 757P AMTA with Pressure Switch r\. I, Bill of Materials 0 I `.�� Item Qty. Description ! 1 1 Restrictor(1/2-inch NPT) Co 2 1 Strainer(1/2-inch NPT) O . ri 3 1 Swing Check(1/2-inch NPT) 1 K 44 1 Slow-Fill Ball Valve "v (Normally Open) 2� 5 1 Spring-Loaded,Soft-Seated 0 1� Check Valve12 I 0 6 1 Pressure Switch �� s ,^ z. 7 2 Compression Fitting,Straight - �4�, (1/4-inch NPT x 1/4-inch Tube) ci 0 �. (46, 0 8 1 Copper Tubing(Y-inch OD) jft, 9 11 Close Nipple ® rl� (1/2-inch NPT x 1.13) \ 4, 10 1 Nipple(1/z-inchNPTx4.00) (, " 11 1 90°Female Elbow(1!z-inch NPT) 12 4 Female Tee(Y/-inchNPT) 13 3 Union(1/2-inch NPT) (4. 14 2 Reducing Bushing ;-" (1/2-inch NPT x 1/2-inch NPT) 'ig.. a 15 1 Fast-Fill Ball Valveo to. ''f! ` (Normally Closed) 0 Iii r © :*. r. r 16 1 Pressure Switch Isolation Ball 0 s ^r. Valve(Normally Open- ` i , 1= Lockable) FROM (v(:. COMPRESSOR iiD TO SYSTEM Exaggerated for clarity . 30.80 4219 Rev G Updated 01/2015 ©2015 Victaulic Company.All rights reserved. victaulic.com 9 ictaulicr victaulic.com I NXT Dry Valve I Series 768 I Publication 30.80 Compressor Requirements: Remote System Test Valve Requirements • Compressor Requirements and Settings for Series 768 The remote system test valve(inspector's test connection) FireLock NXT Dry Valves Installed with Series 746-LPA should contain a UL Listed and/or FM Approved valve Dry Accelerators (normally closed),which can be opened to simulate the Set the air regulator of the Series 757 Regulated AMTA operation of a sprinkler. to 13 psi/90 kPa. The remote system test valve(inspector's test connection) THE SERIES 757P AIR MAINTENANCE TRIM should be located at the most hydraulically ASSEMBLY WITH PRESSURE SWITCH MUST NOT BE demanding location in the release system. USED ON A SERIES 768 FIRELOCK NXT DRY VALVE NOTE: Multiple restrictions on the remote system test INSTALLED WITH A SERIES 746-LPA DRY valve (inspector's test connection) may slow the air ACCELERATOR. decay rate and cause the system to respond slower than required. When a Series 768 FireLock NXT Dry Valve is installed The remote system test valve(inspector's test connection) with a Series 746-LPA Dry Accelerator, the Series 757 Regulated AMTA must be used. NOTE:The use of an air should terminate with an orifice equal to the regulator with a base or risermounted compressor could smallest orifice in the releasing system. cause short cycling, resulting in premature wear of the The remote system test valve(inspector's test connection) compressor. is used to ensure that water reaches the most remote In the event a compressor becomes inoperative, a part of the system within 60 seconds. properly sized tank-mounted air compressor provides the greatest protection for systems installed with a Series 746-LPA Dry Accelerator. In this situation, air can be supplied continuously to the sprinkler system for an extended time period. NOTE:The Series 757 Regulated AMTA must be used with a tank-mounted air compressor or shop air system that continually supplies air to a Series 768 FireLock NXT Dry Valve installed with a Series 746-LPA Dry Accelerator. 411 The air regulator of the Series 757 Regulated AMTA is a relief-type design. Any pressure in the system that is above the set point of the air regulator will be released. Therefore, charging the air regulator above the set point could cause premature operation of a valve installed with a Series 746-LPA Dry Accelerator. NOTE: The series 746-LPA should not be used above 30 psi. If higher pressures are required,the series 746 should be used. Settings for Air Supervisory Pressure Switches and Alarm Pressure Switches Air supervisory pressure switches are required for dry systems and must be set according to the following instructions. NOTE: Switches for Vic-Quick Risers are pre-set at the factory. Wire the air supervisory pressure switches to activate a low-pressure alarm signal. NOTE: In addition,the local authority having jurisdiction may require a high-pressure alarm. Contact the local authority having jurisdiction for this requirement. Set the air supervisory pressure switches to activate at 2—4 psi/14—28 kPa below the minimum air pressure required, but not lower than 10 psi/69 kPa. Wire the alarm pressure switch to activate a water flow alarm. Set the alarm pressure switch to activate on a pressure • rise of 4—8 psi/28—55 kPa. 30.80 4219 Rev G Updated 01/2015 ©2015 Victaulic Company.All rights reserved. victaulic.com 10 ictaulid victaulic.com I NXT Dry Valve I Series 768 I Publication 30.80 Exploded View Drawing— Trim Components (cOus <>Trim) • LISTS Series 768 FireLock NXT Dry Valve (Optional Accessories Also Shown) Bill of Series e ©A 1 Seriesries 7 768 FireLock NXT DryValve 1 2 FireLock Rigid Coupling(Optional/ Sold Separately-Comes Standard V a when VQR Assembly is Ordered) 110 3 Water Supply Main Control Valve From System / (Optional/Sold Separately-Comes ""ted- -- if 0 - Standard when VQR Assembly is Ordered) 10 ' / 4 Drain Swing Check Valve ;; ' - 5 Drip Cup with Cap r 6 Alarm Pressure Switch(Optional/Sold I� J�/ 7.ti Separately-Comes Standard when VQR Assembly is Ordered) ® ' Location 7 Series 729 Drip Check Valve Q 8 Diaphragm-Charge-Line Ball Valve (Normally Open) i hill 9 3-in-1 Strainer/Check/Restrictor _;;) ` 4D ,0 ,, Assembly i 40� 1 I (��/] , 10 Series 760 Water Motor Alarm a t 7`! Q `�•of,� (Optional/Sold Separately) ® 3�\ �_ 11 Alarm Test Ball Valve 0 `. Q ,,,`•. p g g •"� ��', a `. + To Drip Cup 12 E =O.7 G . oipup Lion Bar) � v ��� ®13 ies 749 Auto Drain ®o ( w A 14 Series 746-LPA Dry Accelerator 9 0:. Assembly(Optional/Sold Separately) ' ' �/ ' — C ©� 15 Series 776 Low-Pressure Actuator �� f �l(y ^ ' - To 16 Air Manifold Notet \, Syst1em 17 Air Supervisory Pressure Switch \ I r,.„ (Optional/Sold Separately-Comes N. \ 0 o ID Standard when VQR Assembly is Ordered) m \ \ .... - 18 System Pressure Gauge ` �. \13 \ \ (u� f IES (0-80 psi/0-552 kPa/0-5.5 Bar with Retard) r \ .�� .y, 19 Water Supply Main Drain Valve- ® O� �,%�- \ `�1l f5 Flow Test 'f f�(� I� A. 20 Water Supply Pressure Gauge :•° Pp Y IN `\! jl�, ' _ii L' .moi?►.i (0-300 psi/0-2068 kPa/0-20.7 Bar) V� .r..1----',.\ •�sr�,C t;�, V. 21 Drain Connection Kit(Optional/Sold G1 ��` ��/ ' Separately-Comes Standard when VQR \,, 0 Assembly is Ordered) '' 22 Gauge Valve �-- � .,' 1 23 System Main Drain Valve , 6 T ' '`/� 24 Series 748 Ball Check Valve lf, 0To Ddp Cup kam wale Supply Exaggerated for clarity Optional devices include the Series 75D Water Column Device Kit and the Series 75B Supplemental Alarm Kit. NOTE 1:Connection point for the Series 75D Water Column Device Kit. I For installation of the Series 750 Supplemental Alarm Device,refer to the instructions supplied with the product. • • 30.80 4219 Rev G Updated 01/2015 0 2015 Victaulic Company.All rights reserved. victaulic.com 11 rctaulic° victaulic.com I NXT Dry Valve I Series 768 I Publication 30.80 Exploded View Drawing— • Trim Components: (European Trim: C 40 US Fu+ LPCB (E (yds) ap 104f/01 0832 l J MEA:248-98-E Series 768 FireLock NXT Dry Valve (Optional Accessories Also Shown) Bill of Materials i 1 Series 768 FireLock NXT Dry Valve ©l 2 FireLock Rigid Coupling(Optional/Sold ,, I Separately-Comes Standard when VQR V I Assembly is Ordered) From System IV i 4D /I 3 Water Supply Main Control Valve(Optional/ Air - (Feed -1 T. l 0 Sold Separately-Comes Standard when VQR -t I `= i j� Assembly is Ordered) -- 4 Drain Swing Check Valve b j' I�-J 5 Drip Cup with Cap 6 Alarm Pressure Switch(OptionaVSold 6 - li Location Separately-Comes Standard when VQR 17 0 n Assembly is Ordered) 7 Series 729 Drip Check Valve t�11: 8 Diaphragm-Charge-Line Ball Valve i�...• i �-' Q ,, ty (Normally Open) ' : za *, I ���./: A� j . 9 3-in-1 Strainer/Check/Restrictor / .,�- 0 1 Assembly ® ` I 3 ToDripCup,•- 10 Series 760 Water Motor Alarm //!,tai r•, w� To Ddp Location (OptionaVSold Separately) ( ''.� I r �� (4� n OA 11 Alarm Test Ball Valve ® p G . \ ,/ O flib 12 Diaphragm-Charge-Line Pressure , ., Gauge(0-300 psi/0-2068 kPa/0-20.7 Bar) b \ %- `= �� 13 Series 749 Auto Drain $ • " Syem `I •.~ 14 Series 746-LPA Dry Accelerator Notes \• Assembly(OptionaVSold Separately) _ \- 15 Series 776 Low-Pressure Actuator ® \, \•\ �, "� 16 Air Manifold ?I I `/ t..-— 411 17 Air Supervisory Pressure Switch enV(OptionaVSold ��,/,' \•\ 111 �Separately-Comes Standard when VQR 0 O� 77ti•fes, I fAssembly is Ordered) �fr,j I - 4 18 System Pressure Gauge • •. t'% L: .::.7-'-"-' (0-80 psVO-552 kPa/0-5.5 Bar with Retard) -03-04113--1;11 0 19 Water Supply Main Drain Valve- �y o F. Flow Test I - 0 20 Water Supply Pressure Gauge __ i (0_300 psi/0-2068 kPa/0-20.7 Bar) "kr( �Q 21 Drain Connection Kit(OptionaVSold Separately-Comes Standard when VQR 1` TC pp a `- '-' �® Assembly is Ordered) 41 22 Gauge Valve 23 System Main Drain Valve �� � ��1 6 24 Series 748 Ball Check Valve © F''...7-, yf%r`/` 'J 25 Water Motor Alarm Shutoff Valve 4'�7{rp� (Normally Open)* 'Item 25,water motor alarm shutoff valve,can be closed to prevent water from flowing tr into the Series 760 Water Motor alarm during conditions that are not favorable for the alarm to sound(Le.during a trip test). From Water Supply • 30.80 4219 Rev G Updated 01/2015 ®2015 Victaulic Company.All rights reserved. victaulic.com 12 Nictaulicr I NXT Dry Valve I Series 768 I Publication 30.80 ® WARNING • This product must be installed by an experienced,trained installer, in accordance with 4111/ the instructions provided with each valve.These instructions contain important information. Failure to follow these instructions may result in serious personal injury, property damage, or valve leakage. If you need additional copies of this product literature or the valve installation instructions, or if you have any questions about the safe installation and use of this device, contact Victaulic Company, P.O. Box 31, Easton, PA 18044-0031 USA, Telephone: 001-610-559-3300. Installation Note Reference should always be made to the appropriate Installation,Maintenance,and This product shall be manufactured by Victaulic or to Victaulic specifications.All products Testing Manual included with each shipment of Victaulic products.These manuals are also to be installed in accordance with current Victaulic installation/assembly instructions. available in PDF format on our website at victaulic.com Victaulic reserves the right to change product specifications,designs and standard equipment without notice and without incurring obligations. Warranty Refer to the Warranty section of the current Price List or contact Victaulic for details. Trademarks Victaulic®and FireLock®are registered trademarks of Victaulic Company. 30.80 4219 Rev G Updated 01/2015 ©2015 Victaulic Company.All rights reserved. victaulic.com 13 victaullia ireLock Dev ice SEE VICTAULIC PPUBLICATION 1O.O1 FOR DETAILS 111, Aur Maintenance Trim Assembly- SERIES 757 The FireLock Air Maintenance Trim Package is designed to control the system air pressure when using the Series 756 Dry Valves,Series 758 Actuated Valves,or the FireLock NXT 768 Dry and 769 Acutated Devices for dry sprinkler applications. The Victaulic®Air Maintenance Trim Assembly should be used with a reliable source of continuous(24 hours/day,7 days/week)air available,such as shop air or a tank mounted air compressor with an attached pressure control switch.The high pressure of the supply air is reduced by the integral regulator in the Air Maintenance Trim Assembly to the recommended ,p r , y air pressure based on the water supply pressure. Note:The regulator must be manually set to the recommended air pressure based upon the guidelines given in the Installation and Maintenance Instructions for pneumatic systems.The air maintenance assembly will maintain the set air pressure as long as the supply air pressure is greater then the system air pressure. COMPONENTS Included in the Air Maintenance Trim Assembly are the following components: • High quality regulator which maintains the sprinkler piping air pressure • Strainer—A 100 mesh strainer is used to prevent particles from entering the Air Maintenance System and the sprinkler system. • Restrictor—A brass Restrictor is used in the maintenance loop in order to assure that air cannot enter the sprinkler system faster then air can be discharged through an open head. • Spring Loaded In-line Check Valve—Bubble tight ball check used to isolate the valve air • maintenance system from air leaks in the air supply system. • Fast Fill Line—Used to rapidly restore system air pressure following operation or service. • Recommend maximum of two systems per air maintenance trim. • Regulator is a pressure reducing type. WARNING AA WARNING • This product must be installed by an experienced,trained installer, in accordance with the instructions provided with each valve.These instructions contain important information. Failure to follow these instructions may result in serious personal injury, property damage or valve leakage. If you need additional copies of this product literature or the valve installation instructions or have any questions about the safe installation and use of this device,contact Victaulic Company,P.O.Box 31,Easton, PA 18044-0031 USA,Telephone:001-610-559-3300. JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para • Location Date Approved Date www.victaulic.com VICTAULIC ISA REGISTERED TRADEMARK OF VICTAULIC COMPANY.C 2009 VICTAULIC COMPANY.ALL RIGHTS RESERVED. iCtaul1C ;EVD IPSCARBON STEEL PIPE-FIRE PROTECTION PRODUCTS 30.35 Fire Lock® Devices Air Maintenance Aly0ssemb 757 INSTALLATION&ADJUSTMENT Install the Air Maintenance Trim Assembly in the orientation shown on the appropriate trim drawing. The Air Maintenance Trim Assembly is intended to be used in systems that have a source of com- pressed air available such as shop air or a tank mounted air compressor. Refer to the Installation,Maintenance and Testing Manuals of the particular valve being installed for detailed setting information and procedures. Adjustment To increase the set pressure pull the knob of the regulator out and turn the knob clockwise until the desired pressure is read on the regulator gauge.More accurate adjustment of the system air pres- sure should then be made using the system pressure gauge.After final adjustment lock the regulator by pushing the knob in. To decrease the set pressure pull the knob of the regulator out and turn the knob counterclockwise until the desired pressure is read on the regulator gauge.More accurate adjustment of the system air pressure should then be made using the system pressure gauge.After final adjustment lock the regulator by pushing the knob in. NOTES 1 An air regulator must be used with Series 756/Series 758/Series 768/Series 769 Actuated Valves utilizing an Accelerator. 2 When supervisory air is required,such as in an electrically activated preaction system,the pres- sure should be set as low as the supervisory pressure switch installed will permit. 3 When installed with multiple pneumatic actuated valves,(two maximum)the systems must be • ��� 'l, isolated by using a spring loaded soft seat check valve to assure air integrity to each system. t0 i 7 to. I 1 _,,...---, III . 1,0_ v.:.A mg 6y,"1/4. ,i,.....,i,01-- t"I TieN4111111H"P-1 .1W www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.®2009 VICTAULIC COMPANY.ALL RIGHTS RESERVED. ✓ctau IiC' 30.35_2 sum IPS CARBON STEEL PIPE-FIRE PROTECTION PRODUCTS 3 0.3 5 • FireLock® Air Maintenance irim A SERIES 757 RECOMMENDED AIR PRESSURE FOR DRY 60 AND PNEUMATIC ACTUATED SYSTEMS 50 Pc�uato� a 40 'I53P w CC D vl 30 W CC a Q 20 767,776,and 798 Actuators 10 0 5 10 15 20 25 50 75 100 125 150 175 200 225 250 275 300 MAXIMUM WATER SUPPLY PRESSURE-psi(Peak) COMPRESSOR REQUIREMENTS 26 • 24 22 55 psi/379 kPa - —40 psi/276 kPa - 20 psi/138 kPa 20 13 psi/90 kPa u- 18 16 C 3 14 0 LL 12 •5 10 8 C 8 6 4 2 0 — N N W A (l� (T CP - N W . l0 O O 01 O 01 O W A O O 0 01 p 0, O 01 0 <T p 0 ~ O N O tT O (n O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O System Capacity(in gallons) • www.victaulic.com veCtauli ?ICTAULIC ISA REGISTERED TRADEMARK OF VICTAULIC COMPANY.0 2009 VICTAULIC COMPANY.ALL RIGHTS RESERVED. I FireLorke Deis Pir MainteraricciTr c ,, • SERIES 757 PROPER AIR SUPPLIES FOR SERIES 1.When a riser or base mounted air compressor is being used to supply air to a dry valve or preac- 756/SERIES 758/SERIES 768/SERIES769 tion system it is not necessary to use the air maintenance trim assembly with the air regulator.In this ACTUATED VALVES: circumstance the air line of the compressor is connected to the valve trim at the fitting into which the Air Maintenance Trim is normally installed. When the valve is used with this setup it is the engineer/system designer's responsibility to size the compressor so that the compressor brings the entire system to the required pressure in 30 minutes. The compressor must not be oversized to provide more air flow as this will slow down or possibly prevent the operation of the valve. It must further be emphasized that the base mounted compressor does not provide any backup air to the system and that continuous service(24 hours per day,7 days per week)must be maintained in order to prevent the potential of false tripping of the valve due to loss of air pressure. Additionally,due to the large on/off differential available on pressure switches that control base mounted compressors,the compressor pressure switch must be adjusted so that the"ON"contact of the pressure switch is set a minimum of 5 psi higher than the set point of the regulator. 2.When shop air or a tank mounted air compressor is being used,the Air Maintenance Trim Assembly(AMTA)must be used.The AMTA is designed to provide the proper air regulation to the sprinkler system which will assure the proper operation of the Fire Safety Valve. In the event of a compressor becoming inoperative the tank mounted air compressor provides the greatest protection.With a properly sized tank,air can be continuously supplied to the sprinkler sys- tem for an extended period of time even with a loss of compressor. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. - - -- • NOTE This product shall be manufactured by Victaulic or to Victaulic specifications.All products to be installed in accordance with current Victaulic installation/assembly instructions.Victaulic reserves the right to change product specifications,designs and standard equipment without notice and without incurring obligations. 113 11111111111111111111111111111111 IIIIIIIIIIIIIIIIillllllII1111111111III WCAS-7MYM68 4110 For complete contact information,visit www.victaulic.com 30.35 2515 REV D UPDATED 1/2009 ✓ctaut.c' VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.®2009 VICTAULIC COMPANY.ALL RIGHTS RESERVED. 30.35 0 n F.. k'. C---A I RE 8 i '„'- -..-4 , ,: ,s;t4i'v � 1r 1 'rte r` urs ' a 3 q„ '2 �COMPRESSORS 1i . �� 11 -� x°v � � k� aVair.ra' p kF �, ik •srr $EACsONDS err , '„-,.-.,- ,.f„.,,,,,,,I.,.i arru rtxssm sw�itN QUIET -60. :< +� �/�+a .. . .. , .., , i � Wdie A`R�G,'+. , f i''� i�h'R � ',` is ' M. ♦ .. j Js • l''''” � 4 SET PRESSURE IN SECONDS HP 1 � , , � z IDEAL FOR QUIET SETTINGS SYSTEM CAPACITY 40 PSI 261 GALLONS ,,,,-;*,,,,,,,,,,,,,,,,,,,,,7.,,,,,, , Y y Nursing Homes 20 PSI 522 GALLONS r 10 PSI 1044 GALLONS Apartments -.� - 1,7; -Churches PRESSURE SWITCH ADJUSTABLE:5-55psi FACTORY SET AT 10-20PSI INCLUDES MOUNTING BRACKET AND MINIMUM DIFFERENTIAL:SPSI 30"STEEL BRAIDED FLEX HOSE CFM 3.68@1oPSI .b a, PUMP 2 CYLINDER,011 FREE CYLINDERS CERAMIC COMPOSITE PATENT PENDING i � VOLTS 115 F Listings: - PHASE 1 Pressure Switch: CSA listed to UL 508 Standard(USA) RUNNING AMPS 7.5 CSA listed to C22.2 No.14 Standard(Canada) W �' " "� ----J. BREAKER SIZE 15 AMP RECOMMENDED Compressor: CSA listed to UL 1450 3rd Edition Standard(USA) MOUNTS TO RISERS , OUTLET 3/4"NPT CSA listed toC22.2No. 68 92 Standard(Canada) 5"AND LARGER DIMENSIONS 27"Xlos"X�" 'C' TheAdvantage WEIGHT 38.0 LBS. 380 WEST 1ST STREET,DRESSER,WI 54009 800.762.2247//651.462.3440// WWW.C-AIREINC.COM EAs INSTA1 !'i ON RI-J'- - - t-i : , r . ' O f AN° r.'' '. '::':Y's,'''.': ' ''''' '1._'',:,-±74). . -- MOUNT TO RISER MOUNT TO CINDER BLOCK/CONCRETE WALL Ih . 'Pill" 4 R .. ._ , f4 7-:.....11,140,40,01V 1`..-Ve,,.1.:;'..* ' c "4 ' '▪ ter; t ..,....„,4,4,,,„,„,:.-.,....-` 1.Hammer dull holes for hollow wall 2.Put hollow wall anchor into ho les 1.Install mounting bracket on riser . - anchor ' T ` ' �a, yk, r�s� �h� 0: g-ta "x 'A ` .#ra * . .� „s } ",wd t 2.Hang unit on mounting bracket ' nab a 'i �, `f7 Xt.,, £`r yy „at,a� '' v. , y rF y4 �5 p x7 y 3.Tap hollow wall anchor into cinder 4.Attach mounting bracket to wall block with hammer — ' - • 3.Bolt unit to mounting bracket 4.Install air filter assembly MOUNT TO DRYWALL b� M l'ft ary �� . iei t s,� t7� 'r *,�,:'�;�",T� 5,'''' ,r ri 4;#5 °'' 5.Locate hange on back ofonr 6.Hang unit onto the inounnu g brac,ret 1.Att ch 2.4s to studs in drywall 2.Attach mounting bracket to wall - ,� - o . [ � n F $^ J F �{� M 7._.tip b-R through Or nt to mounting 8.Tighten bolt t,unit and mounting 3.Hang unit onto the inountiitg bracket baeket bracket bracket ra —.4 11- } • V ...,Kro-s✓ W (",,, 4: 5.Tighten bolt to unit and mounting 6.install air filter assembly - bracket 8.1rstal! .,trterassee.bD; O K R r 6405.6425 SERIES IRE DEPT. INLET CONN. EXPOSED TYPE) SINGLE CLAPPER TWO-WAY INLETS 1 = s 4x21/2x21/2 11111 T An exposed auxiliary inlet connection with 500 G.P.M. inlet °$ ` capacity to supplement fire protection water supply. Exposed IIIdesign provides an economical method of satisfying Fire Dept. , • r inlet requirements. STANDARD EQUIPMENT: Cast brass two-way inlet body + P only with single swing clapper and pin lug swivel back or angle ._..._ Figure No. 6405 outlet connection as selected by figure number. 6405 Back Outlet SPECIFY THREAD. BRANDING: "Auto Spkr." FINISH: Cast Brass „w r ' *U/L LISTED IA : OPTIONAL FINISHES: 1411164 PB - Polished Brass RC - Rough Chrome Plated <l PC - Polished Chrome Plated -B Outlet Dimensions /� Model Style A B C (l(l . , < ° 6405 Back 5 1/4 8 5/64 6 1/2 6407 Angle 6 5/16 - 7 11/16 4 3/4 3- Figure No. 6407 6407 Angle Outlet DOUBLE CLAPPER TWO-WAY INLETS • An exposed auxiliary inlet connection with 500 G.P.M. Inlet miiiiiii 4.4 capacity to supplement fire protection water supply. Exposed `,, design provides an economical method of satisfying Fire Sir ie r. Department Inlet requirements. I. s STANDARD EQUIPMENT: Cast brass two-way inlet body only -Ili , • with double drop clappers and pin lug swivels; back or angle i B Figure No. 6410-6415 outlet connection as selected by figure number. Branding 6410 Back Outlet as selected. SPECIFY THREAD AND BRANDING. BRANDING:"Standpipe", "Auto Spkr." D Om E-----. FINISH: Cast Brass f OPTIONAL FINISHES: '„„,, PB- Polished Brass `°� :,, ' ”" RC- Rough Chrome Plated *, PC- Polished Chrome Plated Figure No. 6420-6425 6420 Angle Outlet *U/L LISTED NY BSA-MEA APPROVED Outlet Style Dimensions Back Angle Size A B C D E *6410 4 X 21/2X21/2 9 5/8 12 1/4 6420 4 X 2 1/2 X 2 1/2 11 3/4 9 5/8 7 1/4 6412 6 X 2 1/2 X 2 1/2 10 1/4 11 3/4 6422 6 X 2 1/2 X 2 1/2 12 1/2 10 1/8 7 1/2 6413 4 X 3 X 3 10 12 1/2 III 6423 4 X 3 X 3 12 1/2 101/8 7 1/2 6414 5 X 3 X 3 10 1/8 12 1/2 6424 5 X 3 X 3 12 1/4 10 1/2 7 1/2 6415 6 X 3 X 3 10 3/8 12 1/2 6425 6 X 3 X 3 12 1/4 10 7/8 7 1/4 Page 6-15 6750 sER�E� FIRE DEPARTMENT CONN. ACCESSORIES o Fc BREAKABLE CAPS • For use on Fire Department inlet connections. Prevents entry of foreign matter and AA, protect female threads. Breakable ears feature permits fast hose connection. 71414:: ,,,,, STANDARD EQUIPMENT: Cast iron,Aluminum or plastic cap with breakable ears, 4.0: 71:1',. ' ., '4 two eyebolts with nuts for attachment to female pin lug swivel. SPECIFY SIZE AND COLOR. FINISH: Painted Fig. No. 6750- Model No. Size Finish 6751 R-Red 6750 21/2" Iron G-Green 6751 3" Iron Y-Yellow 6752 2 1/2" Aluminum 6753 2 1/2" Plastic .,4ROUND ESCUTCHEON PLATES „ Used to identify and trim exposed Fire Dept. Connection Installations. , , i; STANDARD EQUIPMENT: Brass or red painted aluminum plate, size and material as selected by figure number. Branding as selected. SPECIFY BRANDING and FINISH. Fig. No. 6760-6766 w BRANDING: "Standpipe", "Auto Spkr.", "Standpipe-Sprinkler", "Dry Standpipe", "Wall ,rt. Hydrant", "Fire Pump Test". (Figure No. 6766"Auto Spkr.", "Standpipe", "Standpipe- Pi Sprinkler"). Special lettering available. Figure No. Size Plate Diameter Material 6758 2 1/2" 6 1/2" Brass 6759 3" 7 5/8" Brass OPTIONAL FINISHES: 6760 4" 9 1/2" Brass 6762 5" 10 5/8" Brass PB- Polished Brass 6764 6" 11 7/8” Brass RC-Rough Chrome Plated Brass Ill 6765 4" Brans 9 1/2/2"" Aluminum PC-Polished Chrome Plated Brass Fig. N6770 6766 4" 9 o. 6770 4"(Sillcock) 9 1/2" Brass RECTANGULAR WALL PLATES 03,4 0 Used for identifying Fire Dept.Connections. r4r STANDARD EQUIPMENT: Brass or red painted 4 1/2"X 10" plate, material as selected ( by figure number. Branding as selected. SPECIFY BRANDING AND MATERIAL. x OPTIONAL FINISHES: Figure No. Material PB- Polished Brass — _,.„ -.4,4ry "v 6778 Brass RC- Rough Chrome Plated Brass PC- Polished Chrome Plated Brass Fig. No. 6778 BRANDING: "Standpipe", "Auto Spkr.", "Standpipe-Auto Spkr.", "Dry Standpipe", "Fire Pump Test".SPECIAL LETTERING AVAILABLE UPON REQUEST. AUTOMATIC BALL DRIP SILLCOCK Used to drain low point of system between swing check , Used to manually drain low point of system valve and Fire Dept. Connection. Must be installed in a between swing check valve and Fire Dept. 47 horizontal position. connection. STANDARD EQUIPMENT: Cast brass straight or angle Fig. No. 6790 connection, Male NPT both ends. Size and Style selected by STANDARD EQUIPMENT: Cast brass figure number. Figure No. Size Style flanged Sillcock with 3/4" Fem. NPT inlet 6780 1/2" Straight X Male G.H.T. ......... OPTIONAL FINISHES: .......... . , .. 6781 3/4" Straight • 6782 1/2" Angle PB- Polished Brass . No. 6783 3/4" Angle RC- Rough Chrome Plated Brass Fig. No. Fig. PC-Polished Chrome Plated Brass 6780-6781 6782-6783 Page 6-22 OK ( HOsE VA LVES► C_______1 SEES } ANGLE VALVES 300LB. RATED Fire Department Valves Fire Hose Rack Assembly Valves Ive FEMALE X MALE DOUBLE FEMALE i STANDARD EQUIPMENT: Female STANDARD EQUIPMENT: Female NPT inlet and male hose thread NPT inlet and outlet cast brass valve outlet cast brass valve with wheel with wheel handle handle. OPTIONAL FINISHES: ` PB-Polished Brass Figure No. 5010-5015 RC-Rough Chrome Plated Figure No. 5020-5025 PC-Polished Chrome Plated SPECIFY U/L LISTED THREAD NY BSA/MEA APPROVED 5010 5015 Figure No. 5020 5025 Size 1 1/2" 2 1/2" E 1 A 211/64 3 3/16 :.+mow B 2 7/32 3 3/16 C-Closed 6 5/8 9 1/4 ,1 i C-Open 7 21/22 11 _ , -.f 11 -.71.t... j'. D 3 3/4 5errubx, .. . E 2 7/16 3 19/32 ` --�-+I F 213/16 319/32 III U/L Listed Yes Yes FM Approved Yes Yes A--;�f E/ NYC Approved Yes Yes 213/16 319/32 ANGLE VALVES 300LB. RATED �" Fire Department ValvesFire Hose Rack Assembly Valves v FEMALE X MALE DOUBLE FEMALE #, . it STANDARD EQUIPMENT: Female STANDARD EQUIPMENT: Female 4. s NPT inlet and male hose thread NPT inlet and outlet cast brass valve i • ,i 4 11114 outlet cast brass valve with wheel with wheel handle $ handle. OPTIONAL FINISHES: PB-Polished Brass Figure No. 5030-5035 RC-Rough Chrome Plated Figure No. 5040-5045 PC-Polished Chrome Plated SPECIFY U/L LISTED THREAD NY BSA/MEA APPROVED 5030 5035 G Figure No. 5040 5045 _~ - Size 1 1/2" 2 1/2" t t--- "-—.) A 2 9/64 3 5/32 rOO B 217/64 3 3/16 I C-Closed 6 1/2 8 3/4 • 1 (II .0t'', r- C-Open 711/16 10 9/16 ` 11 D 4 1/64 5 1/8 ,r� C ..» \` /ii E 2 7/10 3 1/2 it 3""" `j.... - l am3.;'" i -! F 2 3/8 3 3/8 U/L Listed Yes Yes , Page 5-3 otc R7200 SER IES ADAPTERS AND BUSHINGS HEX ADAPTERS 0 DOUBLE MALE DOUBLE FEMALE FEMALE X MALE *at 40 ,.'-' . Figure No.7201 -Cast Brass Figure No.7220-Cast Brass Sizes: 1 1/2"X 1 1/2" 4"X 4" 2 1/2"X 1 1/2" 4 1/2"X 4" Sizes: 1 1/2"X 1 1/2" 3" X 2 1/2" 2 1/2"X 2" 4 1/2"X 4 1/2" 2 1/2"X 1 1/2" 4" X 4" 2 1/2"X 2 1/2" 5" X 5" Figure No.7215-Cast Brass 2 1/2"X 2" 4 1/2" X 4" 3" X 2 1/2" 6" X 4 1/2" Sizes: 1 1/2"X 1 1/2" 2 1/2"X 2 1/2" 6" X 4 1/2" 6" X 6" 2 1/2"X 2 1/2" 6" X 6" ADAPTERS PINLUG OR ROCKERLUG DOUBLE MALE DOUBLE FEMALE FEMALE X MALE SWIVEL Figure No.7230-Cast Brass Figure No.7245 Sizes: 1 1/2"X 1 1/2" Figure No.7235-Cast Brass Sizes: 2 1/2" X 3/4" 2 1/2"X 2" 2 1/2"X 2 1/2" Sizes: 1 1/2"X 1 1/2" 2 1/2" X 1" 3"X 2 1/2" 2 1/2"X 2 1/2" 2 1/2" X 1 1/2" III FEMALE X MALE MALE X MALE FEMALE X MALE BUSHING INCREASER PINLUG ADAPTER NO LUGS OR ROCKERLUG 4 K: - , .- $ , jo Figure No.7255-Cast Brass Figure No.7260-Cast Brass Figure No.7280-Cast Brass Sizes: 1 1/2"X 2 1/2" Sizes: 2 1/2"X 2 1/2" 2" X 2 1/2" 3"X 2 1/2" Sizes: 6"Female NPT X 4"Male NPT 2 1/2"X 3" 8"Female NPT X 6"Male NPT NEW YORK CITY STORZ X STORZ STORZ X THREADED FLOW TEST NIPPLE LIGHTWEIGHT ADAPTER ADAPTER MALE X MALE ,o.,,,,, Figure No.7285 Figure No.7290-Aluminum Figure No.7295-Aluminum Sizes: 3"X 2 1/2" Sizes: 4"X 6" Sizes: 3" X 2 1/2" 5" X 5" (2"INTERNAL THREAD) 5"X 6" 2 1/2"X 2 1/2" 4" X 4" 6" X 6" • OPTIONAL FINISHES PB-POLISHED BRASS RC-ROUGH CHROME PC-POLISHED CHROME OTHER SIZES AVAILABLE UPON REQUEST Page 7-9 5660.5770 SERIES E. VALVES & ACCESSORIES) .„....„ -.....„, CRO K ER PRESSURE RELIEF VALVE CAPS AND CHAINS ,...,'"jt,. Used to cover and protect male outlet threads on valves and For use on all closed systems to prevent damage , hydrants. Prevents entry of foreign matter. in the event of a malfunction due to some foreign i' object or matter becominglodged in an automatic CAST BRASS WITH CHAIN 9 , ,<� regulating or control valve. Featuring a pop-type Fig.No.With Fig.No.With relief action for maximum performance. itPin Lugs Rocker Lugs Size ,,;; ISO 5709 5710 1 1/2 b` 5713 5714 2 1/2 t ---� � } Figure No. 5660 5717 5718 4" Figure No. 5709-5713 9 f 5715 5716 3 fOPTIONAL FINISHES: Figure Press.Set Dimensional Data(Inches) PB-Polished Brass No. (PSI) Inlet Outlet A B C RC-Rough Chrome Plated 5660 15-175 3/4 3/4 3 3 1 PC-Polished Chrome Plated 5661 175 1/2 1/2 1 3/4 1 15/16 SPECIFY THREAD 3/4 Available - with 3/4 Male or 314 female inlet with 3/4" CAST HARDCOATED PLASTIC CAP Female ALUMINUM CAP WITH CHAIN WITH CHAIN Outlet • Fig. Size THREE WAY GAUGE VALVE Fig.No. Size 57211 1 1/2 For use with Sprinkler System gauges. 5720 2 1/2 5722 2 1/2 ' ' NY BSA/MEA Approved 5723 3 .% ` Standard Equipment: 1/4"valve NPT Bronze three way globe valve with handwheel. 1[ Female inlets. 175 PSI. VALVE ESCUTCHEONS Figure No. Size Figure No. 5662 5662 1/4 0 '41' '-'11 GLOBE VALVES RISING STEM For use with Sprinkler System gauges. Used to trim pipe into cabinet. Standard Equipment: Figure No. Size Material Bronze with telfon seat. 5730 1 1/2 Stamped Steel Cadmium Plated 125 WSP. 5735 2 1/2 Stamped Steel Cadmium Plated Figure No. Size Figure No. Size Material 5663 1/4 5750 1 1/2 Cast Brass 5664 3/8 5755 2 1/2 Cast Brass s 5665 1/2 ? 5666 3/4 OPTIONAL FINISHES: 5667 1 PB--Polished brass 5668 1 1/4 RC--Rough Chrome Plated • 5669 1 1/2 PC--Polished Chrome Plated Figure No. 5663-5670 5670 2 I SPECIFY FIGURE NO OPTIONAL FINISHES: SIZE-FINISH RC-Rough Chrome Plated Page 5-18 c o Fc R6840.6893 SERIES FIRE DEPARTMENT CONNECTIONS iROOF MANIFOLD BODIES 0 t 4, .-' o Cast Brass STRAIGHT PATTERN V` If i Figure No. Size Dimensions A B C fr 6840 4 X21/2 X 2 1/2 7 5/8 5 1/2 5 3/8 Fig. Na 6850-6851 Fig. No. 6840-6843 6841 6 X21/2 X21/2 8 3/8 7 7 1/2 1-7— A 6843 6X3X3 9 65/8 65/8 -T- 7..-:----?.' TF -' 6850 4 X 2 1/2 X 2 1/2 X 2 1/2 12 3/4 8 3/4 5 1/4 B \ % 6851 6 X 2 1/2 X 2 1/2 X 2 1/2 15 3/8 9 3/4 7 5/8 ,/-- i-._ C ____.4 ANGLE PATTERN I-- Figure No. Size Dimensions A B C s ,s 6860 4 X 2 1/2 X 2 1/2 7 1/2 7 1/8 4 3/4 6861 6 X 21/2 X 21/2 9 1/4 8 1/2 5 1/4 ' j. 6862 4X3X3 10 83/4 51/4 6863 6 x 3 x 3 97/8 91/2 53/8 Fig. No. 6860-6863 6870 4 X 2 1/2 X 2 1/2 X 2 1/2 12 1/4 7 6 3/8 Fig. No. 6870-6873 I 6871 6X21/2X21/2X21/2 121/4 71/2 63/8 B 6872 4X3X3X3 123/4 7 61/2 IA K:Iji 1 r(00-0-41)1 6873 6 X 3 X 3X 3 12 3/4 7 1/2 6 1/2 i I-I Ill #1� ...l; } Cast Brass-Straight Pattern - IPT or Hose Thread Outlets ILA D NOTE: Specify valves and/or caps if required C �i—IValves and Caps Not included in above Units �'� 1-- CDSpecial threads available upon request. ---I o ROOF MANIFOLD UNITS Cast Brass 4 :' HORIZONTAL Figure No. Size 6880 _ 4X2 1/2X2 1/2 6881 6X2 1/2X2 1/2 Figure No. 6880-6883 6882 4X2 1/2X2 1/2X2 1/2 Figure No. 6890-6893 6883 6X2 1/2X2 1/2X2 1/2 - *6884 6X2 1/2X2 1/2X2 1/2X2 1/2 *6884 unit is furnished with a ductile iron body r) 0 VERTICAL r ' Figure No. Size 6890 4X2 1/2X2 1/2 6892 4X2 1/2X2 1/2X2 1/2 M ; r r Pipe A B C . 0 D 6893 6X2 1/2X2 1/2X2 1/2 pipe A BCD D E • Size Open Closed Size Open Closed 4" 19112 17 5112 11718 10114 4" 18 19 518 6112 11718 10114 5114 6" 19112 17 6114 11718 10114 Valves and Caps included in above Units 6" 18314 20318 8112 11718 10114 7114 Page 6-25 VSR POTF ER VANE TYPE WATERFLOW • t _ The Symbol of Protection ALARM SWITCH WITH RETARD -411 `µ= UL, CUL and CSFM Listed, FM Approved,LPCBApproved,For • ' :.fir'% CE Marked(EN12259-5)/VdS Approved model use VSR-EU Service Pressure: 450 PSI(31 BAR)-UL Flow Sensitivity Range for Signal: 4-10 GPM(15-38 LPM)-UL ... Maximum Surge: 18 FPS(5.5 m/s) Contact Ratings: Two sets of SPDT(Form C) 10.0 Amps at 125/250VAC 2.0 Amps at 30VDC Resistive 10 mAmps min.at 24VDC Conduit Entrances: Two knockouts provided for 1/2"conduit. Individual switch compartments suitable for dissimilar voltages. Environmental Specifi cations: • NEMA 4/IP54 Rated Enclosure suitable for indoor or outdoor use with factory installed gasket and die-cast housing when used with appropriate conduit fi tting. n %p p M I n1 G • Temperature Range: 40°F-120°F,(4.5°C-49°C)-UL !! • Non-corrosive sleeve factory installed in saddle. • Installation must be performed by qualifi ed personnel and in Service Use: accordance with all national and local codes and ordinances. Automatic Sprinkler NFPA-13 • Shock hazard.Disconnect power source before servicing.Serious One or two family dwelling NFPA-13D injury or death could result. Residential occupancy up to four stories NFPA-13R • Risk of explosion.Not for use in hazardous locations.Serious National Fire Alarm Code NFPA-72 injury or death could result. • Optional: Cover Tamper Switch Kit,Stock No.0090148 General Information Drain the system and drill a hole in the pipe using a hole saw in a slow The Model VSR is a vane type waterfl ow switch for use on wet speed drill.(see Fig. 1) sprinkler systems. It is UL Listed and FM Approved for use on steel Clean the inside pipe of all growth or other material for a distance equal pipe;schedules 10 through 40,sizes 2"thru 8"(50 mm thru 200 mm). to the pipe diameter on either side of the hole. LPC approved sizes are 2"thru 8"(50 mm thru 200 mm). See Ordering Roll the vane so that it may be inserted into the hole;do not bend or Information chart. crease it. Insert the vane so that the arrow on the saddle points in the The VSR may also be used as a sectional waterfl ow detector on direction of the waterfl ow. Install the saddle strap and tighten nuts large systems. alternately to required torque. (see Fig. 1).The vane must not rub the The VSR contains two single pole,double throw,snap action switches inside of the pipe or bind in any way. and an adjustable,instantly recycling pneumatic retard. The switches Specifi cations subject to change without notice. are actuated when a flow of 10 GPM (38 LPM) or more occurs downstream of the device. The fi ow condition must exist for a period Ordering Information of time necessary to overcome the selected retard period. Nominal Pipe Size Model Part Number Enclosure 2" DN50 VSR-2 1144402 The VSR switches and retard device are enclosed in a general purpose, 2 1/2" DN65 VSR-2 1/2 1144425 die-cast housing. The cover is held in place with two tamper resistant screws which require a special key for removal. A field installable 3" DN80 VSR-3 1144403 cover tamper switch is available as an option which may be used 3 1/2" - VSR-3 1/2 1144435 to indicate unauthorized removal of the cover. See bulletin number 4" DN100 VSR-4 1144404 5401103 for installation instructions of this switch. 5" - VSR-5 1144405 Installation: See Fig. 1 These devices may be mounted on horizontal or vertical pipe. On 6" DN150 VSR-6 1144406 horizontal pipe they should be installed on the top side of the pipe 8" DN200 VSR-8 1144408 where they will be accessible. The device should not be installed within 6" (15 cm) of a fitting which changes the direction of the waterfl ow or within 24"(60 cm)of a valve or drain. • Potter Electric Signal Company• 2081 Craig Road,St.Louis,MO,63146-4161 • Phone:800-325-3936/Canada 888-882-1833• www.pottersignal.com PRINTED IN USA MFG.#5401146-REV H PAGE 1 OF 3 12/07 Ty. VSR pP(JTTER VANE TYPE WATERFLOW The Symbol of Protection ALARM SWITCH WITH RETARD • mow AXPESWIWAYM-2MVIMPWIWIPZIMIMMIMUlliS Fig.1 OY RTAMPER SWD R Fig.2 Switch Terminal Connections RETARD ADJUSTMENT �> Clamping Plate Terminal THE DEL CANES TKNO®BYROTO DIE THE \ /IA RD ADJUSTMENT KNOB FROM OTO THE MAX '�'� OT,FnVE COVER OFF FOA i•i "I SETTING(POPOS SECONDS)THE TIME DELAY SHOULD D. BE SET AT TIM MUM REQUIRED TO PREVENT LXT'ENDFD PFRRIDOF TME FALSE ALARMS "�"�/�\� JADATER G pA� \I^ �� ADAPTER `- lN� ` ,'/<3'1,001_,,,g,' �,V� O Mum*Noun MAX. ''���'l►- I.i DN50 ONLY r �G USE(2)5180162 ADAPTERS AS SHOWN ABOVE EGD V�� oN�,I�IT ° DWG,9�J J U .'V MOUNT oNrme so OUNT ON SADDLE Y '� POINTS IN DIRECTION f j//� ^N I _ PWA PR DW 'rnY,HIK` � An unmsulated section of a single conductor Yshould not be looped around theterminaland RQLLP^°°LENserve as two separateconnections. The wire must OPPOSRE DIRECTIONJF WATERFLQW be severed,thereby providing supervision of the DIRECTION OPconnectionintheeventthatthewire becomeWATERP DW:Ilk dislodged from under the terminal. Failure to P sever the wire may render the device inoperable DWG.L�E risking severe property damage and loss of life. (Flowing water activates device in one direction only.) Installation Requirements A CAUTION Model Nominal Pipe Size Nominal Pipe O.D. Hole Size U-Bolt Nuts Torque Waterfl ow switches that are monitoring wet pipe inch mm inch mm inch mm ft-lb n-m sprinkler systems should not be used as the sole VSR-2 2 DN50 2.375 603 initiating device to discharge AFFF, deluge, or chemical suppression systems. Waterft ow switches VSR-2 1/2 21/2 2.875 73.0 1.25+.1251-.062 33.0±2.0 used for this application may result in unintended III VSR-2 1/2 2 1/2 DN65 3.000 761 discharges caused by surges,trapped air,or short retard times. VSR-3 3 DN80 3.500 88.9 VSR-3 1/2 31/2 4.000 101.6 20 27 VSR-4 4 DN100 4.500 114.3 2.00±.125 50.8±2.0 VSR-5 5 5.563 141.3 VSR-6 6 DN150 6.625 168.3 VSR-8 8 DN200 8.625 219.1 Fig.3 Typical Electrical Connections Fig.4 Fig.5 t ® NEGATIVE Break out thin section of cover when wiring both To remove knockouts:Place screwdriver at ® NSE°oaAL switches from one conduit entrance. inside edge of knockouts,not in the center. AC POSITIVE IX'CR LI0<'t OR HOT AC (�r�'t}llill= m \ i } rxmFB WATERFLOW ZONE �� ON FIRE PANEL / ! '41111111 _ o/ Notes: 1.� �� 1. The Model VSR has two switches,one can be used i'7\ I�I1 to operate a central station,proprietary or remote i,` �> l.� P P P ry -:\\�J X1,-,(f signaling unit,while the other contact is used to `��-f%i operate a local audible or visual annunciator. 1 1*4 2. A condition of LPC Approval of this productis that the electrical entry must be sealed tor�1; ,0 exclude moisture. — ��� 3. For supervised circuits see "Switch Terminal 111110 -� i Connections"drawing and caution note(Fig.2). .-:..--.P. III PRINTED IN USA MFG.#5401146-REV H PAGE 2 OF 3 12/07 VSR PPOTTER VANE TYPE WATERFLOW • The Symbol of Protection ALARM SWITCH WITH RETARD Compatible Pipe Note:For copper or plastic pipe use Model VSR-CF. Model Nominal Pipe Nominal Pipe Pipe Wall Thickness Size O.D. Schedule 10(UL) Schedule 40(UL) BS-1387(LPC) DN(VDS) inch mm inch mm inch mm inch mm inch mm inch min VSR-2 2 DN50 2.375 60.3 0.109 2.77 0.154 3.91 0.142 3.6 0.091 2.3 VSR-2 1/2 21/2 2.875 73.0 0.120 3.05 0.203 5.16 VSR-2 1/2 DN65 3.000 76.1 0.142 3.6 0.102 2.6 VSR-3 3 DN80 3.500 88.9 0.120 3.05 0.216 5.49 0.157 4.0 0.114 2.9 VSR-3 1/2 31/2 4.000 101.6 0.120 3.05 0.226 5.74 VSR-4 4 DN100 4.500 114.3 0.120 3.05 0.237 6.02 0.177 4.5 0.126 3.2 VSR-5 5 5.563 141.3 0.134 3.40 0.258 6.55 VSR-6 6 DN150 6.625 168.3 0.134 3.40 0.280 7.11 0.197 5.0 0.157 4.0 VSR-8 8 DN200 8.625 219.1 0.148 3.76 0.322 8.18 0.248 6.3 0.177 4.5 Testing The frequency of inspection and testing for the Model VSR and its associated protective monitoring system should be in accordance with applicable NFPA Codes and Standards and/or the authority having jurisdiction(manufacturer recommends quarterly or more frequently). If provided,the inspector's test valve,that is usually located at the end of the most remote branch line,should always be used for test purposes.If there are no provisions for testing the operation of the fl ow detection device on the system,application of the VSR is not recommended or advisable. A minimum fl ow of 10 GPM(38 LPM)is required to activate this device. Maintenance Inspect detectors monthly for leaks. If leaks are found,replace the detector. The VSR waterfl ow switch should provide years of trouble-free service. • The retard and switch assembly are easily fi eld replaceable.In the unlikely event that either component does not perform properly,please order replacement retard switch assembly stock#1029055.There is no maintenance required,only periodic testing and inspection. Removal • To prevent accidental water damage,all control valves should be shut tight and the system completely drained before waterfl ow detectors are removed or replaced. • Turn off electrical power to the detector,then disconnect wiring. • Loosen nuts and remove U-bolts. • Gently lift the saddle far enough to get your fi ngers under it. With your fi ngers,roll the vane so it will fi t through the hole while continuing to lift the waterfl ow detector saddle. • Lift detector clear of pipe. Important Notice Please advise the person responsible for testing of the fire protection system that this system must be tested in accordance with the testing instructions. Mounting Dimensions 89,0 mm (3.50") GROUND SCREWS _ 141,2 mm I r (2.34") �, (5.56")®i'�'•fwui'� 59,4 mm �� � 50,8 mm Wilt -., (2 001 11__61 U-BOLT NUT '._I_.� ����� , • `O U-HOLT WASHER ■■_A-`.. 13P[PE3.4DIA.mm .��. mum pr nail\ PIPE SADDLE lir . PIPE '' t' PLASTIC PADDLE U-HOLT • NOMINAL PIPE DIA.+44,5 mm(+1-3/4)FOR DN50-DN65(2-2-1/2") NOMINAL PIPE DIA.+54,0 mm 1+2-1/8")FOR DN80-DN200(3-8") 01908 11466 PRINTED IN USA MFG.#5401146-REV H PAGE 3 OF 3 :2/07 PS10 SERIES The Symbol of Protection PRESSURE SWITCH • AMMIORMI~- (UL, cUL, and CSFM Listed, FM and LPC Approved, NYMEA Accepted,CE Marked Pending) Dimensions:3.78"(9,6cm)W x 3.20"(8,Icm)D x 4.22"(10,7cm)H ( POlfR Conduit Entrance:Two knockouts provided for 1/2"conduit. Individual switch compartments and ground screws suitable for n C E PS10-2 dissimilar voltages. ' Enclosure: Cover-Die-cast with textured red powdercoat fi nish,single cover screw and rain lip. Base-Die-cast • - Pressure Connection:Nylon 1/2"NPT Male Factory Adjustment: 4-8 PSI(0,27-0,55 BAR) Differential: 2 PSI(0,13 BAR)typical Maximum System Pressure: 300 PSI(20,68 BAR) Patent Pending Switch Contacts: SPDT(Form C) 10.1 Amps at 125/250VAC,2.0 Amps at 30VDC Ordering Information One SPDT in PS10-1,Two SPDT in PS10-2 Model Description Stock No. Environmental Specifi cations: PS10-1 Pressure switch with one set 1340103 NEMA 4/IP55 Rated Enclosure-indoor or outdoor when used SPDT contacts with NEMA 4 conduit fi ttings. PS10-2 Pressure switch with two sets 1340104 Temperature range:-40°F to 140°F(-40°C to 60°C) SPDT contacts Service Use: Hex Key 5250062 Automatic Sprinkler NFPA-13 Cover Tamper Switch Kit 0090200 One or two family dwelling NFPA-13D Tamper Residential Occupancy up to four stories NFPA-13R Cover incorporates tamper resistant fastener that requires a special key for National Fire Alarm Code NFPA-72 removal.One key is supplied with each device. For optional cover tamper IIIswitch kit,order Stock No.0090200. See bulletin#5401200 PSCTSK. Installation The Potter PS10 Series Pressure Actuated Switches are designed for the into alarm port piping on the input side of retard chamber and electrically detection of a waterfl ow condition in automatic fi re sprinkler systems of connect PS 10 to control unit that provides a retard to compensate for surges. particular designs such as wet pipe systems with alarm check valves,dry Insure that no unsupervised shut-off valves are present between the alarm pipe,preaction,or deluge valves. The PS10 is also suitable to provide a check valve and PS10. low pressure supervisory signal;adjustable between 4 and 15 psi(0,27 and Method 2: When using the PS10 for local bell application or with a control 1,03 BAR). that does not provide a retard feature-the PS 10 must be installed on the alarm 1.Apply Tell on tape to the threaded male connection on the device. outlet side of the retard chamber of the sprinkler system. (Do not use pipe dope) Testing: Accomplished by opening the inspector's end-of-line test valve. 2.Device should be mounted in the upright position(threaded connection down). Allow time to compensate for system or control retard. 3.Tighten the device using a wrench on the fl ats on the device. Note: Method 2 is not applicable for remote station service use,if there is an Wiring Instructions unsupervised shut-off valve between the alarm check valve and the PS 10. nve the Yam erre i taut rearr'a - - 1.Rem p s s s r with the spe r I]rey provided Wet System With Ex�P��pxessure- -- -- --- 2.Carefully place a screwdriver on the edge of the knockout and Connect PS 10 into alarm port piping extending from alarm check valve. sharply apply a force suffi cient to dislodge the knockout plug.See Fig 9 Retard provisions are not required. Insure that no unsupervised shut-off 3.Run wires through an approved conduit connector and affi x the connector valves are present between the alarm check valve and the PS 10. to the device. Testing: Accomplished by opening the water by-pass test valve or the 4.Connect the wires to the appropriate terminal connections for the inspector's end-of-line test valve.When using end-of-line test,allow time service intended.See Figures 2,4,5,and 6.See Fig 7 for two switch,one for excess pressure to bleed off conduit wiring. Dry System Testing Connect PS10 into alarm port piping that extends from the intermediate The operation of the pressure alarm switch should be tested upon completion chamber of the alarm check valve. Install on the outlet side of the in-line of installation and periodically thereafter in accordance with the applicable check valve of the alarm port piping. Insure that no unsupervised shut-off NFPA codes and standards and/or the authority having jurisdiction valves are present between the alarm check valve and the PS10. (manufacturer recommends quarterly or more frequently). Testing:Accomplished by opening the water by-pass test valve. Wet System Note: The above tests may also activate any other circuit closer or water Method 1: When using PS10 and control unit with retard-connect PS 10 motor gongs that are present on the system. Potter Electric Signal Company• 2081 Craig Road,St.Louis,MO,63146-4161 • Phone: 800-325-3936/Canada 888-882-1833• www.pottersignal.com • PRINTED IN USA MFG.#5400928-REV D PAGE 1 OF 3 1/08 P POTTER PS10 SERIES • The Symbol of Protection PRESSURE SWITCH 1111/1=1/1111111111111/11M9FM"919993MOTAMMI9390"09,43II3/40,0A04631,99F9M91,439MIIIIIIININFM3- I° Dimensions Switch Clamping Plate Terminal Fig. 1 Fig.2 VIInc� 1 00i P GROUND �,�o � 1 1 SCREWS ��, �("� � 2.87 1 1 T/' ADJUSTMENT II■ [72.97] �' . �/ KNOB ■ I ® 4.22 1 1'h�'` �_i [107.19] OI n �% Milli l' tali) 7 ,c,,' Gov DWG#923-3 1/2"NPT o‘'s —I 60 [62 87] I— [40.64] PA WAR N 9 N G 3.78 _ f 3.20 _, An uninsulated section of a single conductor [95.89] [81.28] should not be looped around the terminal and serve as two separate connections. The wire NOTE:To prevent leakage,apply Teflon tape sealant to male threads only. must be severed,thereby providing supervision of the connection in the event that the wire DWG#9301 becomes dislodged from under the terminal. Typical Sprinkler Applications Fig.3 WET SYSTEM WITH WET SYSTEM WITHOUT DRY SYSTEM EXCESS PRESSURE EXCESS PRESSURE • PSIO PSIO WATER WATER PSIO WATER MOTOR MOTOR MOTOR GONG GONG GONG REVS CHECK WET RBVS DRY VALVE REVS SYSTEM WET SYSTEM ALARM . .., SYSTEM. ALARM ALARM CHECK VAALLVE CHECK RETARD VALVE VALVE I.i WATER WATER WATER OS&Y ♦ BY-PASSOS&Y V BY-PASS GS&Y ♦ BY-PASS VALVE • VALVE ,'aI VE • VALVE DWG.#923-2AA A CAUTION Closing of any shutoff valves between the alarm check valve and the PS10 will render the PS 10 inoperative.To comply with NFPA-72 any such valve shall be electrically supervised with a supervisory switch such as Potter Model RBVS. Low Pressure Signal Connection Waterfl ow Signal Connection Local Bell For Waterfl ow Connection Fig.4 Fig.5 Fig.6 TO FIRE ALARM PANEL TO FIRE ALARM PANEL NEGATIVENEUTRAL DC OEAC r rdo POSITIVE DC LINE LOAD OR HOT AC -_w --,r. 3-i■-, -_-- _ aria I4 , ILOo oO o ® IiOo 0 o IIII ._ ,°til --���I�� X1111 owca czx-z nwcn nsa PRINTED IN USA MFG.#5400928-REVD PAGE 2 OF 3 1/08 P POTTER PS10 SERIES The Symbol of Protection PRESSURE SWITCH • One Conduit Wiring Switch Operation Removing Knockouts Fig.7 Fig.8 Fig.9 Break out thin section of divider to provide path for wires Terminal W/PRESSURE APPLIED C:Common NC when wiring both switches from one conduit entrance. 1: Closed when installed under normal system rr pesure. 1��n, ,n�; 1 Q° �° 2: OOpen when installedH under normal system pressure.Closes on ` 40 r JI. o o ® r. 1. pressure drop.Use for ^.. r r_ low pressure ,i1� ' �� supervision. /: 'III E' Pli�� Terminal W/O PRESSURE APPLIED I ��, - �_���• _ t __� 1: Open with no pressure NOS, ', supplied.Closes upon �; / �_ detection of pressure. �V y � ', Use for watertl ow "p° C�� indication. dl \r"(-' 2: Closed with no DWG#928-5 DWG#928-4 pressure applied. DWG#928-6 .ffi n WARNING A CAUTION -Installation must be performed by qualifi ed personnel and in -Do not tighten by grasping the switch enclosure.Use wrenching accordance with all national and local codes and ordinances. flats on the bushing only.Failure to install properly could damage •Shock hazard.Disconnect power source before servicing. the switch and cause improper operation resulting in damage to Serious injury or death could result. equipment and property. -Read all instructions carefully and understand them before •To seal threads,apply Tefl on tape to male threads only. Using starting installation.Save instructions for future use.Failure to joint compounds or cement can obstruct the pressure port inlet read and understand instructions could result in improper and result in improper device operation and damage to equipment. operation of device resulting in serious injury or death. •Do not over tighten the device,standard piping practices apply. -Risk of explosion.Not for use is hazardous locations.Serious injury or death could result. Engineer/Architect Specifi cations Pressure Type Water('ow Switch Pressure type waterfl ow switches;shall be a Model PS10 as Pressure switch shall have one or two form C contacts,switch contact manufactured by Potter Electric Signal Company,St Louis MO., rating 10.1 Amps at 125/250 VAC,2.0 Amps at 30 VDC. and shall be installed on the fi re sprinkler system as shown and or Pressure type waterfl ow switches shall have two conduit entrances specifi ed herein. one for each individual switch compartment to facilitate the use of Switches shall be provided with a'/2"NPT male pressure connection dissimilar voltages for each individual switch. and shall he connected to the alarm port outlet of;Wet Pipe Alarm The • • - , •.. ;ie-cast Valves,Dry Pipe Valves,Pre-Action Valves,or Deluge Valves.The with rain lip and shall attach with one tamper resistantscrew.The pressure switch shall be actuated when the alarm line pressure reaches Pressure type waterfl ow switch shall be suitable for indoor or outdoor 4-8 PSI(0,27-0,55 BAR). service with a NEMA 4/IP55 rating. Pressure type waterfl ow switches shall have a maximum service The pressure type waterfl ow switch shall be UL Ulc and CSFM listed, pressure rating of 300 PSI(20,68 BAR)and shall be factory adjusted FM and LPC approved and NYMEA accepted. to operate on a pressure increase of 4-8 PSI(0,27-0,55 BAR) • imosta-k _ s.,,n .Y,ai*c.M•.'-wviW-t?Yi§.'Yrm .ais 63`k.'"a. e' S...-41.,,, PRINTED E;USA MFG.#5400928-REV D PAGE;01 1/08 • P POTTER MODEL PS40 The Symbol of Protection PRESSURE SWITCH "_ - - ����• (UL, cUL, and CSFM Listed, FM and LPC Approved, NYMEA Accepted,CE Marked Pending) Dimensions:3.78"(9,6cm)W x 3.20"(8,1cm)D x 4.22"(10,7cm)H � r a Conduit Entrance: Two knockouts provided for 1/2"conduit.Individual " .) 1 1 1._: switch compartments and ground screw suitable for dissimilar voltages C f Enclosure: Cover-Die-cast with textured red powdercoat fi nish,single PS40 cover screw and rain lip. Base-Die-cast Pressure Connection:Nylon 1/2"NPT male Factory Adjustment: PS40-1 operates on decrease at 30 PSI(2,1 BAR) PS40-2 operates in increase at 50 PSI(3,5 BAR) and on decrease at 30 PSI(2,1 BAR) Pressure Range: 10-60 PSI(,7-4,1 BAR) Maximum Differential: Approximately I lb.at 10 PSI(,07 at,7 BAR) 4 lbs at 60 PSI(,28 at 4,1 BAR) Maximum System Pressure: 250 PSI(17,2 BAR) Switch Contacts: SPDT(Form C) 10.1 Amps at 125/250VAC,2.0 Amps at 30VDC One SPDT in PS40-1,Two SPDT in PS40-2 Environmental Specifi cations: NEMA 4/IP55 Rated Enclosure-indoor or outdoor when used with NEMA 4 conduit fi ttings. Temperature range:-40°F to 140°F(-40°C to 60°C) Tamper: Cover incorporates tamper resistant fastener that requires a special key for removal. One key is supplied with each device. Ordering Information For optional cover tamper switch kit,order Stock No.0090200. • Model Description Stock No. See bulletin#5401200 PSCTSK. PS40-1 Pressure switch with one set SPDT contacts 1340403 Service Use: PS40-2 Pressure switch with two sets SPDT contacts 1340404 Automatic Sprinkler NFPA-13 Hex Key 5250062 One or two family dwelling NFPA-13D Cover Tamper Switch Kit 0090200 Residential Occupancy up to four stories NFPA-13R BVL Bleeder valve 1000018 National Fire Alarm Code NFPA-72 Installation The Potter PS40 Series Pressure Actuated Switches are designed primarily to 4. Connect the wires to the appropriate terminal connections for the detect an increase and/or decrease from normal system pressure in automatic service intended. See Figures 2,4,5,6,and 8 fi re sprinkler systems. Typical applications are:Dry pipe system,pre-action Adjustment And Testing air/nitrogen supervision,pressure tanks,air supplies,and water supplies. The operation of the pressure supervisory switch should be tested upon The PS40 switch is factory set for 40 PSI(2,8 BAR)normal system pressure. completion of installation and periodically thereafter in accordance with The switch marked with the word LOW is set to operate at a pressure decrease the applicable NFPA codes and standards and/or the authority having of 10 PSI(,7 BAR)at 30 PSI(2,1 BAR). The switch marked with the word jurisdiction(manufacturer recommends quarterly or more frequently). HIGH is set to operate at a pressure increase of 10 PSI(,7 BAR)at 50 PSI Note: Testing the PS40 may activate other system connected devices. (3,5 BAR). See section heading Adjustments and Testing if other than The use of a Potter BVL(see product bulletin 8900067 for details)is factory set point is required. recommended to facilitate setting and testing of the PS40 pressure switch. 1. Connect the PS40 to the system side of any shutoff or check valve. When a BVL(bleeder valve)is used,the pressure to the switch can be 2. Apply Tefl on tape to the threaded male connection on the device. isolated and bled from the exhaust port on the BVL without effecting the (Do not use pipe dope) supervisory pressure of the entire system. See Fig.3 3. Device should be mounted in the upright position. The operation point of the PS40 Pressure Switch can be adjusted to any (Threaded connection down) point between 10 and 60 PSI(0,7-4,11 BAR)by turning the adjustment 4. Tighten the device using a wrench on the fl ats on the device. knob(s)clockwise to raise the actuation point and counter clockwise to Wiring Instructions lower the actuation point. In the case of the PS40-2,both switches operate 1. Remove the tamper resistant screw with the special key provided. independent of each other. Each switch may be independently adjusted to 2. Carefully place a screwdriver on the edge of the knockout and sharply actuate at any point acrosss the switch adjustment range. Initial adjustment apply a force suffi cient to dislodge the knockout plug. See Fig.9 can be made with a visual reference from the top of the adjustment knob 3. Run wires through an approved conduit connector and affi x the across to the printed scale on the switch bracket. Final adjustments should connector to the device. A NEMA-4 rated conduit fi tting is be verifi ed with a pressure gauge. • required for outdoor use. Potter Electric Signal Company • 2081 Craig Road,St.Louis,MO,63146-4161 • Phone: 800-325-3936/Canada 888-882-1833• www.pottersignal.com niefflIMMINPIPIMENEWWWWWWWft PRINTED IN USA MFG.#5400930-9/07 PAGE 1 OF 3 REV C P P( )TIER MODEL PS40 R The Symbol of Protection PRESSURE SWITCH • Dimensions Switch Clamping Plate Terminal Fig. 1 Fig.2 GROUND I I i 00 2.87 I of r 1 SCREWS `1 `eco ADJUSTMENT I I I [72.97] I %� � � KNOB I'-.-�_ ® 4.22 �� � ■ j 1/.1_ �/ 1_ �1 [107.19] 1__=l 1)4, ,.,.. 011' MN 1/2"NPT ��0O'AC) DWG,.923-3 O 2.48 i— 1.60 [62.87] [40.64] 3.703.20 _# [95.89] —_ `- [81.28] A WA R N I N G NOTE:To prevent leakage,apply teflon tape sealant to male threads only. An uninsulated section of a single conductor should not be looped around the terminal and serve as two separate connections. The wire must be severed,thereby providing supervision of the connection in the event that the wire becomes dislodged from under the terminal. Typical Sprinkler Applications Fig.3 PS40 A CAUTI O N AIR LINE IP VALVESHUT-OFF A BLEEDER PSIO Closing of any shutoff valves between the VALVE y TEST PPRAfi SURE • alarm check valve and the PS 10 will render CHECK A VALVE SWITCH VALVE BVL the PS10 inoperative.To comply with NEPA- WATER 72 any such valve shall be electrically --> MOTOR GONG supervised with a supervisory switch such as CHECK RBVS DRY PIPE VALVE Potter Model RBVS. VALVE ,41 0.41 WATER DWG.4924-IA OS Sc Y ♦ BY-PASS VALVE A TEST VALVE Typical Connections Fig.4 WITH NORMAL SYSTEM PRESSURE PS40-I PS40-2 APPLIED LOW-TERMINAL 2 CLOSES ON PRESSURE DROP. TO FIRE ALAPANEL 1�1/�■1��/1 HIGH COM 'MIMI AIR Higm, eri, ,/�� ©� COM uUiiu iwi.. COM ©® WITH NORMAL SYSTEM IIIIIIIIIIIIIIIr ..i.n. �� Et1.1] LOW PRESSURE APPLIED HIGH TO FIRE E' OLR" pi AIR TERMINAL 1 WILL CLOSE ALARM IMIIIIIIIIIIIIIIIIMI ON PRESSURE INCREASE. PANEL 11 EOLR IIII PRINTED IN USA MFG.#5400930-9/07 PAGE 2 OF 3 REV C P POTTER MODEL PS40 .,, .. • The Symbol of Protection PRESSURE SWITCH Low Pressure Signal Connection High Pressure Signal Connection One Conduit Wiring Fig.5 Fig.6 Fig.7 Break out thin section of divider to provide path for wires TO FIRE ALARM PANEL TO FIRE ALARM PANEL when wiring both switches from one conduit entrance. E��13 r JJrit , - ri- n� - OO�� t i—� a ®_ I, v11 - ,......., Changing Pressure Removing Knockouts (With normal system pressure) Fig.9 Fig.8 LOW PRESSURE SWITCH For low pressure NC use:Corn and C Terminal 1 r1 jbIlk • C , z 14:14W A lip;HIGH PRESSURE SWITCH For waterfl ow NC \ il�4 j* /441 171 \ ...til,, , use:Com and c ®, or Terminal NO 4<4 / ./ i C t 2 Engineer/Architect Specifi cations Pressure Type Waterll ow Switch WARNING n' Pressure type supervisory switches;shall be a Model PS40 as manufactured by �'YY71 R 1 V G Potter Electric Signal Company,St.Louis,MO.,and shall be installed on the fire .'_ -Installation mU tbeperformed by qualid ed personnel and in accordance with al sprinkler system as shown and or specifi ed herein. national and local codes and ordinances. Switches shall be provided with a 1/2"NPT male pressure connection to be -Shock hazard.Disconnect power source before servicing.Serious injury or death connected into the air supply line on the system side of any shut-off valve.A could result. Model BVL bleeder valve as supplied by Potter Electric Signal Company of St. •Read all instructions carefully and understand them before starting installation. Louis,MO.,or equivalent shall be connected in line with the PS40 to provide a Save instructions for future use. Failure to read and understand instructions could means of testing the operation of the supervisory switch.(See Fig.3) result in improper operation of device resulting in serious injury or death. The switch unit shall contain SPDT(Form C) switch(es). One switch shall be •Risk of explosion.Not for use is hazardous locations.Serious injury or death could result. set to operate at a pressure decrease of 10 PSI(0,7 BAR)from normal. If two switches are provided,the second switch shall be set to operate at a pressure ® ����' increase of 10 PSI(0,7 BAR)from normal. ON Switch contacts shall be rated at 10.1 Amps at 125/250VAC and 2.0 Amps at 30VDC. The units shall have a maximum pressure rating of 250 PSI(17,2 BAR) •Do not tighten by grasping the switch enclosure. Use wrenching 11 ats on the bushing and shall be adjustable from 10 to 60 PSI(0,7 to 4,1 BAR). only. Failure to install properly could damage the switch and cause improper operation resulting in damage to equipment and property. Pressure switches shall have two conduit entrances,one for each individual switch -To seal threads,apply Teti on tape to male threads only. Using joint compounds or compartment to facilitate the use of dissimilar voltages for each individual switch. cement can obstruct the pressure port inlet and result in improper device operation and The cover of the pressure switch shall be zinc die-cast with rain lip and shall attach damage to equipment. III with one tamper resistant screw. The pressure switch shall be suitable for indoor orDo not over tighten the device,standard piping practices apply. outdoor service with a NEMA-4/IP55 rating. The pressure switch shall be UL,ULC,and CSFM listed,FM and LPC approved and NYMEA accepted. IIIIIIMINIIM. PRINTED IN USA MFG.#5400930-9/07 PAGE 3 OF 3 REV BELLS T The Symbol of Protection PBA-AC & MBA-DC • UL,ULC,and FM Approved Sizes Available: 6"(150mm),8"(200mm)and 10"(250mm) Voltages Available: 24VAC 120VAC 12VDC(10.2 to 15.6)Polarized 24VDC(20.4 to 31.2)Polarized Service Use: Fire Alarm General Signaling Burglar Alarm Environment: Indoor or outdoor use(See Note 1) -40°to 150°F(-40°to 66°C) (Outdoor use requires weatherproof backbox.) Termination: AC Bells-4 No. 18 AWG stranded wires 0 i FM DC Bells-Terminal strip v* Finish: Red powder coating Optional: Model BBK-1 weatherproof backbox Model BBX-1 deep weatherproof backbox These vibrating type bells are designed for use as fire,burglar or general Notes: signaling devices. They have low power consumption and high decibel 1. Minimum dB ratings are calculated from integrated sound pressure ratings.The unit mounts on a standard 4"(101mm)square electrical box measurements made at Underwriters Laboratories as specified in UL for indoor use or on a model BBK-1 weatherproof backbox or BBX-1 Standard 464. UL temperature range is-30°to 150°F(-34°to 66°C). deep weatherproof backbox for outdoor applications. Weatherproof 2. Typical dB ratings are calculated from measurements made with a backbox model BBK-1,Stock No. 1500001. conventional sound level meter and are indicative of output levels in an actual installation. 3. ULC only applies to MBA DC bells. • Size inches Voltage Model Stock Current Typical dB at Minimum dB at (mm) Number Number (Max.) 10 ft.(3m)(2) 10 ft.(3m)(1) 6(150) 12VDC MBA-6-12 1750070 .12A 85 76 8(200) 12VDC MBA-8-12 1750080 .12A 90 77 10(250) 12VDC MBA-10-12 1750060 .12A 92 78 6(150) 24VDC MBA-6-24 1750100 .06A 87 77 8(200) 24VDC MBA-8-24 1750110 .06A 91 79 10(250) 24VDC MBA-10-24 1750090 .06A 94 80 6(150) 24VAC PBA246 1806024* .17A 91 78 8(200) 24VAC PBA248 1808024* .17A 94 77 10(250) 24VAC PBA2410 1810024* .17A 94 78 6(150) 120VAC PBA1206 1806120* .05A 92 83 8(200) 120VAC PBA1208 1808120* .05A 99 84 10(250) 120VAC PBA12010 1810120* .05A 99 86 All DC bells are polarized and have built-in transient protection. *Does not have ULC listing. 4 WA R N I.t G In outdoor or wet installations,bell must be mounted with weatherproof backbox,BBK-1 or BBX-1.Standard electrical boxes will not provide a weatherproof enclosure.If the bell and/or assembly is exposed to moisture,it may fail or create an electrical hazard. Potter Electric Signal Company, LLC • St. Louis, MO, • Phone: 866-572-3005/Canada 888-882-1833 • www.pottersignal.com • PRINTED IN USA MFG.#5400776-REV Y-1 PAGE 1 OF 2 01/13 • P POTTER BELLS ® The Symbol of Protection PBA-AC & MBA-DC Bells Dimensions Inches(mm) Wiring(rear view) Fig. 1 Fig.3 1 A.C.BELLS WHITE(AI) WHITE(OUT) 10" (250) 8,. 1 l FROM CONTROL(200) 6++ CEDINGPANEL R B ItiliAll _ (150) U� PRECEDING BELL _ — BLACK(IN) _I—IIIIIIIP BLACK(OUT) [ ]) L CAUTION: WHEN ELECTRICAL SUPERVISION IS REQUIRED USE IN AND OUT LEADS AS SHOWN. 2 11/16" (68) DWG#776-1 NOTES: I.WHEN USING AC BELLS,TERMINATE EACH EXTRA WIRE SEPARATELY AFTER LAST BELL. 2.END-OF-LINE RESISTOR IS NOT REQUIRED ON AC BELLS. DWON 776-1 Weatherproof Backbox Dimensions Inches(mm) Fig.2 FACP Box has one threaded 1/2"conduit entrance "ill o I• 5 3/4" _ 3 3/8" 5" I To Next (146) (86) (127) Device or End-of-Line tK e _� Resistesistror3(86) (41) 1— 4 1/4" _,. (108) Installation DWG#776-2 1. The bell shall be installed in accordance with NFPA 13,72,or local AHJ.The top of the device shall be no less than 90"AFF and not less than 6"below the ceiling. '� 2. Remove the gong. . 3. Connect wiring(see Fig.3). 0 4. Mount bell mechanism to backbox(bell mechanism must be -'2. / mounted with the striker pointing down). /D 5. Reinstall the gong(be sure that the gong positioning pin,in the mechanism housing,is in the hole in the gong). /0, 6. Test all bells for proper operation and observe that they can uBX-i Z be heard where required(bells must be heard in all areas as designated by the authority having jurisdiction). .. .., b+ . n,. AWARNING Failure to install striker down will prevent bell from operating. 411 PRINTED IN USA MFG-#5400776-REV Y-i PAGE 2 OF 2 1,13 Identification Signs F P P I® Description Manufactured from .020"white coated aluminum.All sign types are screen printed with a fade resistant red ink. Each sign is shipped with a clear protective plastic coating which can be re- moved at time of installation. Each sign type meets or exceeds NFPA13 requirements. All signs (except 7" round) are drilled in four corners to allow for easy installation.All signs (except 7" round) may be installed with sign chain or with any fastener that is suitable for the material. SPR that the sign is being attached.The 7" round bell signs are center drilled to allow for installation S . 4 <00 directly to the bell gong assembly.Type"A" 9" x 7" Control valve signs are drilled with the same four hole pattern as Type "B" 6"x 2"signs to allow for attachment of Type "B"to Type"A". Cf‘[ Mt. istits; Installation Specifications Installation of aluminum signs is accomplished by several methods.The most common installation procedure is to use#16 Single Jack chain to hang the Material: .020"aluminum with sign on the area being identified. Since all of the above mentioned signs are removable plastic coating predrilled at all four corners,the last link of the chain can be opened and hooked through the topholes on the signs and hungon theappropriate valve orpiping. Sizes: 96"x2" The signs may also be fastened to a flat surface with fasteners appropriate to 4"x 6" • the base material. (The 9" x 7" Fire Alarm Bell sign must be drilled with a 3/8" hole 5"x 7" if it is to be attached directly to the bell gong.) 9"x 7" 12"x 10" 8.5"x 11" 7"Round See current catalog for a full listing of all available signs. 3198 LIONSHEAD AVE CARLSBAD, TEL 60 599-1168 +1 800 344-1822 FAX+1 800 344-3775 • ©2012 Fire Protection Products,Inc. II ITT! Spare Sprinkler Head Storage Cabinet FPPI" Description Fire Protection Products, Inc. Spare Sprinkler Head Cabinets are designed to allow for spare sprinkler head storage as required by NFPA guidelines.The Spare Sprinkler Head Cabinets are available in six configurations.Three head, six head, six head ESFR, twelve head, twenty-four head and thirty-six head.All six styles are manufactured with "knockouts"to accommodate the most common size sprinklers. The shelf is located to allow for the storage of a typical sprinkler head wrench. Each cabinet is finished with a red enamel finish. Each spare head cabinet comes with a hinged door which remains closed to protect the spare sprinklers from the elements and features two holes on the back panel to allow for attachment to most surfaces utilizing the appropriate fasteners. Not intended for exposed or harsh environments. Installation Specifications Select the correct Spare Sprinkler Head Cabinet in accordance with the Automatic Sprinkler Systems Handbook.Asper the 1989 Edition the correct Material:ne P Y Painted Plain Steel number of spare sprinkler is as follows: Finish: 0-300 sprinklers, not less than 6;300-1000, not less than 12; 1000 or more, Red enamel not less than 24. Stock of spare sprinklers shall include all types and ratings Styles: installed.* 3 Spare sprinklers,1 or 3/4 6 Spare sprinklers,1 or 3/4 6 Spare, ESFR,1/2,34 or 1" Once the correct Spare Sprinkler Head Cabinet has been selected, installation 12 Spare sprinklers 1/2 or 3/4 is accomplished by inserting the correct fastener in each of the two holes inside 24 Spare sprinklers the cabinet, securing the cabinet securely to the wall.The insert the correct 36 Spare sprinklers number and type of sprinklers in accordance with the"handbook". *Final determination is subject to approval by the AHJ. 3198 LIONSHEAD AVE CARLSBAD, CA 92010 TEL+1 760 599-1168 +1 800 344-1822 FAX+1 800 344-3775 2012 Fire Protection Products.Inc. I1 11 11 Sprinkler Gauge F P P I° Description FPPI pressure gauges feature an impact and corrosion resistant case made from ABS(plastic). Features phosphor bronze bourdon tube movement with white enameled brass dial face with large numbers for easy reading. Dual scale to 300 PSI/2000Kpa. UL/ULc Listed (Sprinkler Gauge Model 111.10SP UL Listed file EX5232)and FM Approved. �. Applications Standard Features Specifications • Fire sprinkler systems Design • Suitable for all media that will not EN 837-1 &ASME B40.100 Bourdon Tube Material:copper alloy C-type obstruct the pressure system or Sizes attack copper alloy parts 4" (100 mm) Pressure Connection Accuracy class Material:copper alloy '/a" NPT lower mount(LM) Special Features ±3%% of span 4111• UL-listed (UL-393), United States (ASME B40.100 Grade B) Movement and Canada(Sprinkler Gauge Ranges Copper alloy Model 111.10SP, UL Listed file 0/80 psi, retard to 250 psi (air) Dial EX5232) 0/300 psi (air, water, air/water) White aluminum with stop pin; • Factory Mutual (FM)approved Working Pressure black and red lettering • Reliable and economical Steady: 3A of full scale value Pointer Fluctuating: % of full scale value Black aluminum Short time:full scale value Operating Temperature Case Black polycarbonate Ambient: -40°F to 140°F (-40°C to 60°C) Window Media: 140°F(+60°C) maximum Snap-in clear polycarbonate Temperature Error Additional error when temperature changes from reference temperature of 68°F(20°C) +0.4% for every 18°F (10°C) rising or falling. Percentage of span. 3198 LIONSHEAD AVE CARLSBAD, CA 92010 iii TEL+1 760 599-1168 L" ! +1 800 344-1822 - FAX+1 800 344-3775 • ©2012 Fire Protection Products,Inc. ,_, MADE IN U.S.A. 11 11 11, , I I