Loading...
MST2023-00085 (3) 23-or Project No.: 2312 Sheet No.: COVER M—Crk0UP Project HARRIS RESIDENCE HEADER REVIEW Massaad Engineering Group Inc. Client SHANA HARRIS www.mgroupengineering.com Date: JAN 2023 Engineer: JHW STRUCTURAL CALCULATIONS FOR HARRIS RESIDENCE 13518 SW HILLSHIRE DR TIGARD, OR 97223 -- HEADER REVIEW -- Approved plans shall be on job 0 IgliCTUR,14 S PRO,e LIABILErt The City of Tigard and its EGON Q1 t .... OFFICE COPY14:1111iCLYr0=1:wrie°p«,%ies which may appear herein. CITY OF TIGARD EXPIRES:12/31/24 . : VALIDITY OF PERMIT REVIEWED FO /CODE COMPLIANCE THE ISSUANCE OF A PERMIT BASED ON CONSTRUCTION Approved: [ 1 .-.' DOCUMENTS AND OTHER OTC: E 1 . DATA SHALL NOT PREVENT Permit#: ity\ -ri,-,62,-2,-- DE)013..c— THE CODE OFFICIAL FROM Address: REQUIRING THE CORRECT'ON ‘-/-Ak c6 Lcki,) 14;its ek.'ir).-- r)i OF ERRORS. ORSC 105.4 Suite #: By: W Date: Vicilz. Contents Details A-b D1 -D2 Calculations Cl -C7 23-007 Project No.: 2312 Sheet No.: D1 lVlI-GIOUP Project HARRIS RESIDENCE HEADER REVIEW Massaad Engineering Group Inc. Client SHANA HARRIS www.mgroupengineering.com Date: JAN 2023 Engineer: JHW Ci 1 1 ` 1 I 1 I 1 I 1 J J , 14, NEW 9'-a' WINDOW '.' : r, 1 II i I 'k W II i I ,,I I II I I _ .r. ,,. . I it I I r .. 1 IL1J SiRUCTURg4 �Ic%tt PRO,e t`�G 1 N F 4',, 54520 9 •REGON 2 'BASEMENT PLAN fey" 2 SSP° EXPIRES:12/31/24 23-007 Project No.: 2312 Sheet No.: D2 lV[—GIoUP Project HARRIS RESIDENCE HEADER REVIEW Massaad Engineering Group Inc. Client SHANA HARRIS www.mgroupengineering.com Date: JAN 2023 Engineer: JHW - `T— iII 11 II 1 ' H--,,,:- -7—'111 I ' II I _— 1 AT EXISTING CHAP, 134 x 1114 (MINIMUM) 1.9E II BLOCK SOLID 4916' o/c LVL REINFORCING TIGI-IT TO (E) DBL TOP fEs iv M \ ,' 1 I / - -(E) 4x10 HEADER.1 1 VERIFY HEADER IS I I CONTINUOUS. TWO ROWS 144> x 4' SIMPSON 'SDS' SCREWS e16" o/c—TIIII ,,I `''' IIII% 1''� SECTION 13/4 x 111/2 (MINIMUM) 1.9E LVL REINFORCING ii(E) 4x10 HEADER BEYOND ----- ----------- _ J L J L J L J 1-J 1.--1 L_ 1--- I BEAR NEW LVL ON (E) 2x— ' 1 I STUD EACH END 1 ' �-(E) STUD UNDER 4x -�,r HEADER EACH END, VERIFY S,o Ru c T uR,y< ELEVATION ,3tt�PROFFss�o 54520 �' l �-,1 1' t •REGON Cook DETAIL C�By 11' z O SSPP C. MN EXPIRES:12/31/24 23-007 Project No.: 2312 Sheet No.: IIVE-GROUP Project HARRIS RESIDENCE HEADER REVIEW Massaad Engineering Group Inc. Client SHANA HARRIS www.mgroupengineering.com Date: JAN 2023 Engineer: JHW 21-007 Project No.: 2312 Sheet No.: Cl 1VlI—GIoUP Project HARRIS RESIDENCE HEADER REVIEW Massaad Engineering Group Inc. Client SHANA HARRIS www.mgroupengineering.com Date: JAN 2023 Engineer: JHW THIS WALL LINE WAS ORIGINALLY DESIGNED TO ACCOMODATE THREE SETS (3) 3'x5' WINDOWS. THE EXISTING WALL PANELS ARE IN BASIC CONFORMANCE TO THE ORIGINAL DESIGN INTENT. HOWEVER, THE HEADERS (FOR FUTURE 3X5 WINDOWS) WERE NOT DESIGNED FOR A SINGLE 9'-0' OPENING. THE INSTALLED 4x10 WILL NEW TO 5E REINFORCED. 14 03 "i [ 1 11 I I I I I I 1 I I I i I I I I _. I i I I I 1 I I1,. I ,I I 3.1' 1.01 43' 2' 9 0' 3�o' I 1 1 s.. i. ,r 52' if i 64. 1@8' 52' I 'a 54.0' t 7 II I I . I II I I TA )ill _ i4a - Nd I II I I J. IL1J Wall Wind Seismic VWIND VSEISMIC L vw vs Line Load Load Shear Panels(w,h) lbs lbs ft plf plf lbs lbs Maximum Aspect Ratio 3.5 :1.0 Roof Loads Defualt Panel Height(u.n.o.) 9'-0" 1 2,250 1,320 20.0 2,250 1,320T 20.0' 113 66 A Third Floor Loads Defualt Panel Height(u.n.o.) 9'-0" 1 1,525 1,200 20.0 3,775 2,520w 20.0' 189 126 A Second Floor Loads Defualt Panel Height(u.n.o.) 8'-0" 1 1,220 1,200 3.7 7.I 4.3 5.2 3.6 4,995 3,720' 23.3' 214 159 A 23-007 Project No.: 2312 Sheet No.: C2 M—GRPUP Project HARRIS RESIDENCE HEADER REVIEW Massaad Engineering Group Inc. Client SHANA HARRIS www.mgroupengineering.cprn Date: JAN 2023 Engineer: JHW i 1 ! ! ! ii , t I ! Ii 1 f� ���f I if 11 1II 1. t I II I . ). II , ' I a ;A i ;',', it, 1'7 its'. 'I r ; ;i { r i)l i 1t a 13 I C ROOF W oL 15 per LL 20 psr TL 35 psr 23-007 Project No.: 2312 Sheet No.: C3 IV[—GIOUP Project HARRIS RESIDENCE HEADER REVIEW Massaad Engineering Group Inc. Client SHANA HARRIS www.mgroupengineering.com Date: JAN 2023 Engineer: JHW , ,4' A. ,>.f"-?'Sa?---,,.,:r , /:, . 1 1 r. _ -1•I: 11 i i -i i%, I -I it 1�i H 1 E rr t' , I IL r' 1 _ .I r s i�. s 1 III) I It II 11 �'I I (: ( ,' N I 1 f, 1.1 1 r j I In „7. ', 1(_. I. i L I 1: 1 . . 1 , - 1 I SECOND FLOOR W oL 15 Ivor LL 30 per TL 45 per 23.007 Project No.: 2312 Sheet No.: C4 _G p Tp Project HEADER REVIEW Massaad Engineering Group Inc. Client SHANA HARRIS www.mgroupengineering.com Date: JAN 2023 Engineer: JHW ii I II , i I} i' II III I { I 1 i 11 1 I 1 i ry I II. 1 i 1 II li �! I it ii r I . 1 [f i { I1 ,: 1 I 1.€ 1 7 I S MA FLOOR Uf='PE IR DECK W DL 15 per W DL 10 per LL 40 per LL 60 per TL 55 per TL 10 per 23-007 Project No.: 2312 Sheet No.: C5 l\I-GIOUP Project HARRIS RESIDENCE HEADER REVIEW Massaad Engineering Group Inc. Client SHANA HARRIS www.mgroupengineering.com Date: JAN 2023 Engineer: JHW 4 HEADER PSF PSF PSF PSF PSF PSF PSF PSF PSF DL LL SL TW DL LL SL TW DL LL SL TW 15 30 -- 1.5' 2nd 15 -- 20 6.0' ROOF 15 -- -- 6.0' ROOF 15 40 -- 75' 1st 15 20 -- 1.5' 2nd 15 20 -- 1.5' 2nd 10 60 -- 4.4' DECK 15 25 -- 7.5' lat 15 25 -- 15' at 10 35 -- 4.4' DECK 10 35 -- 4.4' DECK S -- -- 20' WALL S -- -- 20' WALL L shall be not less than 0.50L,for members supporting one floor and L shall be not less than 0.40L„for members supporting Iwo or more floors.. L-L.fo.25* in REINFORCE THE (E) 4x10 HEADER WI 134x111"4 LVL W KLL = 1.O b A AT = g' a (1.5' + 7.5' + 4.4') D 4L WORSE CASE = 141 ft 2 i e 9'"0r L = Lo = 0.621 W Beam#1 Beam#2 A A 4x10 LVL 11/4 x 11.875 I DF-L No.2 LVL 1.9 E E(ksi) 1,600 1,900 9'-(f�' I(in4) 231 244 Total 833,338 %Load 0.443 0.557 4x10 DF-L No.2 RI, _.__..R? RI R2 R D 2,336 2,336 _ Rot_ 2,237 2,237 L 2,271 2,271 _,. LL 2,113 2,113 s 540 540 n. 4,349 4,349 brg L 2.35" 2.35" brg L 1.33" 1.33" V V M V MAX 4,349 lbs lbs lbs fi-lbs M MAX 9,786 ft-lbs D+L 4,607 4,607 10,365 D+S 2,876 2,876 6,470 V (d) 3,604 lbs D+/<L+%4 S 4,444 4,444 9,999 fv 213 > 207 psi Main Member fb 2,492 > 1,080 psi f 74 < 180 psi fv 167 < 180 psi Sl fb 1,043 < 1,080 psi _ A DL -0.21 ALL -0.20 Reinforceing Member L/535 fv 145 < 285 psi A SL -0.05 fb 1,590 < 3,120 psi , L/+999 A D+L -0.41 Si L/264 A DL -0.09 s A Dts -0.26 ALL -0.08 i______ L/423 L/+999 0+'/4 L+3/S ok Am -0.39 Am -0.17 L/274 , L/631 CR 1.00 CL 1.00 j CR 1.00 1 Ct. 1.001 CD 1.15 _ Cf 1.201 CD 1.00', Cf 1.201 23-007 Project No.: 2312 Sheet No.: C6 l\'l-GROUP Project HARRIS RESIDENCE HEADER REVIEW Massaad Engineering Group Inc. Client SHANA HARRIS www.mgroupengineering.com Date: JAN 2023 Engineer: JHW � - - - - - - - - - - - <` - mi j 400 sq.ft C 400/36 = 11' Q 2150 lbs io• 1 • • • a�■ I 14 la m. 1 1 I. Ibs• 1525 1 .^ , ,n �...,..... 1,220 Ibs,.. ,...11,�if 1i 1.r, 11, * PR€aa....hRE TREATED A ,CtT iFt^.DE \MV jr ....E-,i -: .... E ....„.,� ..... £......._.1 : I ? --. -.::.- WIND SEISMIC WIND CONTROLS 10.0 psf 11'-0" 110 plf El Wall 0.071 * l0psf * 9'-0" * 5 / 2 = 16plf Roof 0.071 * 15psf * 54'-0" = 57p1f 9.5psf 4'-6" 43p1f = 73p1f 153 plf 36'-0" 2,751 lbs I2 Wall 0.071 * 10psf * 13'-6" * 2 / 2 = 10plf 2nd 0.071 * 15psf * 54'-0" = 57p1f 9.5 psf 4'-9" 45 plf = 67p1f 8.7psf 4-6" 39p1f El Wall 0.071 * lOpsf * 13'-6" * 2 / 2 = 10plf 85 plf 36'-0" 1,523 lbs 1st 0.071 * 15 psf * 54'-0" = 57 plf = 67 plf 8.7 psf 4'-9" 42 pIf 73 plf* 36'-0" / 2 = 1,317 lbs 67 plf* 36'-0" / 2 = 1,202 lbs 8.7 psf 4'-6" 39 p If Tapers from 0 plf-39 plf 67 plf* 36'-0" / 2 = 1,2021bs 1,220 lb s 3,721 lbs WIND TOTAL: 5,313 lbs 2;-00' Project No.: 2312 Sheet No.: C7 1\'l-GIOUP Project HARRIS RESIDENCE HEADER REVIEW Massaad Engineering Group Inc. Client SHANA HARRIS www.mgroupengineering.com Date: JAN 2023 Engineer: JHW _ ? 4 Nr" '� '� rn��w 9 �' F ; Wind Speed: 98 mph Exposure: B Mean Height(h): 30'-0" Width(x): 30'-0" Topographic Feature: Homogeneous Length(y): 30'-0" Height of Hill(h) 0 ft Crest Length(Lii) 0 ft qh: 14.64 psf-LRFD Crest to Structure Dist(x) 0 ft IIX I l Y Ka: 0.85 Ki : 0.00 Cp: 0.80 0.80 windward KZt: 1.00 K2 : 0.00 Cp: -0.50 -0.50 leeward K3 : 0.00 Gust: 0.86 0.86 IIX IIY l Leeward qh*Cp*Gust = -3.8psf qh* Cp* Gust = -3.8psf Windward kz qz* Cp * Gust Total qz* Cp* Gust Total 33'-0" 0.720 6.2psf 10.0 psf 6.2psf 10.0 psf 0.665 5.7 psf 9.5 psf 5.7 p s f 9.5 psf 15'-0" 0.575 5.0psf 8.7 psf 5.0 psf 8.7 psf ASCE 7-16 Standard Lat: 45°25' 19.16"N Ss and S1=Mapped Spectral Acceleration Values Long: 122°48'59.79" W 13518 SW Hillshire Dr,Tigard,OR 97223 Ground Motion Ss 0.848 Si 0.396 Occupancy Category II Light Framed walls with wood shear panels Site Class D R 6.5 Impportance Factor 1.00 Height of Structure 30.0 ft Structural Period T 0,256 Site Coefficients Ct 0,020 Fa 1.16 x 0.75 Fv 1.61 Cs SDsI/R 0.101 SMs Fa* Ss 0.984 Cs MAX SDI I/T R (T<TL) 0.255 SMI Fv* Si 0,637 CS MIN 0.044 SDI I 0.029 Sus (2/3)SMs 0.656 V Cs*WP 0.101 WP SDI (2/3)SM1 0.425 ASD =V* 0.7 0.071 WP Seismic Design Category SDC D