Loading...
02-February (2) CITY OF TIGARD MASTER PERMIT II, COMMUNITY DEVELOPMENT Permit#: MST2024-00068 T t rtA j T 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 02/20/2024 Parcel: 1 S 135CC01200 Jurisdiction: Tigard Site address: 10365 SW MEADOW ST Subdivision: MEADOW,THE Lot: 13 Project: TUSON-TURNER Project Description: Solar photovoltaic system 3.78 kW.STRUCTURAL UPGRADE REQUIRED. BUILDING Floor Areas Required Setbacks Required Stories: 0 Bedrooms: 0 First: 0 sf Basement: 0 sf Left: 0 Parking Spaces: 0 Height: 0 Bathrooms: 0 Second: 0 sf Garage: 0 sf Front: 0 Smoke Dwelling Units: 0 Third: 0 sf Right: 0 Detectors: Total: 0 sf Value: $2,646.00 Rear: 0 PLUMBING Sinks: 0 Water Closets: 0 Washing Mach: 0 Laundry Trays: 0 Rain Drain: 0 Urinals: 0 Lavatories: 0 Dishwashers: 0 Floor Drains: 0 Sewer Lines: 0 SF Rain Drains: 0 Storm Sewer: 0 Tubs/Showers: 0 Garbage Disp: 0 Water Heaters: 0 Water Lines: 0 Catch Basins: 0 Footing Drain: 0 Ice Maker: 0 Hose Bib: 0 Backwater Value: 0 Bckflw Prevntr: 0 Drywell-Trench Drain: 0 Other Fixtures: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: N Vent Fans: 0 Clothes Dryers: 0 Heat Pump: N Hoods: 0 Other Units: 0 Furn<100K: 0 Vents: 0 Woodstoves: 0 Gas Outlets: 0 Furn>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less: 0 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea add'I 500 sf: 0 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 1 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All N Other: N Other Description: Ecompasing: BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: OTR SF VB R-3 0 Owner: Contractor: TUSON-TURNER,MADELEINE ION DEVELOPER LLC Required Items and Reports(Conditions) 10365 SW MEADOW ST 3214 NORTH UNIVERSITY AVE TIGARD,OR 97223 503 PROVO,UT 84604 PHONE: PHONE: (888)781-7074 FAX: Total Fees: $377.31 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR oc9_nn1_nntn fhrn,,nh oc9_nn1_nnon Vn,,m nhf i v c nn of fhn ndce nr rlirrf ni, cfinnc+n ni iMcm 91 n 91A C by Tallinn c9 10R7 nr 1 An 110 A ,, y Issued By: �iG%' Permittee Signature: > ' 7p �4 CSC t Gil Call 503.639. 7:00 a.m.for the next available inspection date. This permit card shall be kept i conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. Building Permit Application n -Cl of Tigard -- Received ;City g .. Date/By: P./ / -i1737 Permit No.lu T A 0__/'��p e e) / 13125 SW Hall Blvd.,Tigard,OR 97223 CITY OF TIGtRu I / - C.V`� �' Plan Review Phone: 503.718.2439 Fax: 503.598.196011111 ate/By: Other Permit: BUILDING D 2 13 _ i i( \k i 'Inspection Line: 503.639.4175 ) ate Ready/By: ///,,,,,,��� Jung: ® See Page 2 for Internet: www.tigard-or.gov Notified/Method: 1 i'tt/per 49 ��� Supplemental Information yr1i lI - 6,,,.. ,_:_. 9 .w,'^ ,stgltir.., ,a,,asx nro. ,,.a44 ... a+ s ,x.:vx:.uZ4e,4.wn ;..maxu rm `</i y AA„,_,—+ �' ❑New construction ❑Demolition Permit fees*are based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all ❑Addition/alteration/replacement ®Other: PV Solar equipment,materials,labor,overhead,and the profit for the ,, � , ay work indicated on this application. ... Y .,..�..i�„_�.4 :_ - Win.. ® 1-and 2-family dwelling 0 Commercial/industrial Valuation: $ 2,646 ❑Accessory building ❑Multi-family Number of bedrooms: ❑Master builder 0 Other: Number of bathrooms: . 1CA vj number of floors: " Total Job site address: 10365 SW Meadow Si New dwelling alp:' Blinn feet`' City/State/ZIP: Tigard,Oregon 97223 Garage/carport area: square feet Suite/bldg./apt.no.: I Project name: Tuson-Turner Solar Install Covered porch area: square feet Cross street/directions to job site: Deck area: square feet Other structure area: square feet •,,,.°1 QUI P DAT Itr*C-fJ~ ': fiS C:1"C ' : Subdivision: The Meadow I Lot no.: 13 Permit fees*are based on the value of the work performed. Tax map/parcel no.: 1 S 135CC01200/R273670 Indicate the value(rounded to the nearest dollar)of all / 6.x equipment,materials,labor,overhead,and the profit for the P .,,D fF+ WORK , ,t. „,,: i .: work indicated on this application. ��. E' PTI�I� Installation of solar panels on existing residential roof. Valuation: $ 3.78 kW.Addition of 1 circuit. Existing building area: square feet New building area: square feet _, .sv; •, _ e ,, Number of stories: Name: Madeleine Tuson-Turner Type of construction: Address: 10365 SW Meadow St Occupancy groups: ' City/State/ZIP: Tigard,Oregon 97223 Existing: Phone:((360))317-7400 Fax:( ) New: Business name: ION Developer LLC Structural plan review fee(or deposit): Contact name: Dustin Davidson LS lan review fee(if applicable): _ry F p Address`: 4�FEast 800-North _ . e Total fees due upon application: City/State/ZIP:Orem,_Utah,84057 Phone: (385)396-4478 I Fax::( ) Amount received � ��E-mail:permits@ionsolar.com ,, , ',a 7. Commercial and residential prescriptive installation of • _ , t2,.' ' ' _ roof-top mounted Photovoltaic Solar Panel System. Business name: ION Developer LLC Submit two(2)sets of roof plan with connection details and fire department access,along with the 2010 Oregon Address: 44 East 800 North Solar Installation Specialty Code checklist. City/State/ZIP: Permit Fee(includes plan review • y Orem, Utah,84057 ... ____.. .. _._.- . _ .._.. ,_w-and-administrative f _._._..., -...., 80 00 fees):--- $1 (w.#,. .)—.-, State surcharge(12%of permit fee): $21.60 CCB lie.: 230394 Total fee due upon application: $201.60 Authorized signature: '2 a This permit application expires if a permit is not obtained •f•"' within 180 days after it has been accepted as complete. Fee h Print name: Dustin Davidson Date: 02-09-2024 *Service Bodard.gy sit*Tri County Building 7itdustry I:\Building\Permits\BUP-RESPennitApp.doc 02/24/2011 440-4613T(11/02/COM/WEB) ` `in4:4*hn't 1,''et 13 � 4'00,Cs1tl ,,. . x a . '> • Electrical PermitE1 V Application City of Tigard F F R 1 ? ZQ Received _ Date/By: Permit#: �r�ra , 13125 SW Hall Blvd.,Tigard,OR`97223 r^ Tom '(/w Plan Review Phone: 503.718.2439 Fax: 503.598.196074 -�/ TtU' � Date/By: Related Permit#: Inspection Line: 503.639.4175 CITY t i�� eady Date/By: Juts: ® Page 2 for 1 1 c e;\ I) Internet: www.tigard-or.gov Bu`D,NG Df•,SINotified/Method: C] Supplemental Information :.."r.. ,. "'. '' r tF "`f s . ll �;"�a 5 i dr.°f "' s t H.., El New construction ElAddition/alteration/replacement Please check all thatf apply(submit 2 sets of plans w/items checked): ❑Demolition E Other: PV Solar ❑Service or feeder 400 amps or more 0 Building over three stories. where the available fault current ❑Marinas and boatyards. dwelling 0 'Y TM k„ exceeds 10,000 amps at 150 volts or a �� � p 0 Floating buildings. �� ,� w .w,., ��.«.�� ,.Man ,.��.,� ,. .. E 1-and 2-familyCommercial/industrial 0 Accessory building less to ground,or exceeds 14,000 0 Commercial-use agricultural ❑Multi-family ❑Master builder amps for all other installations. buildings. ❑Other0Fire pump. 0 Installation of 150 KVA or .< - q I F.610 1 ti l `I0 1 x y-y ❑Emergency system. larger separately derived Job#: I ❑Addition of new motor load of system. Job site address: 10365 SW Meadow St I00HP or more. ❑ °A", `E","1-2","1-3' City/State/ZIP: Tigard,Oregon 97223 ❑Six or more residential units. occupancy. 0 Health-care facilities. 0 Recreational vehicle parks. Suite/bldg./apt.#: I Project name: Tuson-Turner Solar Install ❑Hazardous locations. 0 Supply voltage for more than 0 Service or feeder 600 amps or more. 600 volts nominal. Cross street/directions to job site: , .... , New residential single-or multi-family dwelling unit. Subdivision: The Meadow Lot#: 13 Includes attached garage. Tax map/parcel#: 1S135CC01200/R273670 1,000 sq.ft.or less 168.54 4 Ea.addl.500 sq.ft.or portion 33.92 1 . .€ , A . n- . OW : ..,..4....' ,,4, Limited energy,residential Installation of solar panels on existing residential roof. (with above sq.ft.) 75.00 2 Limited energy,multi-family 3.78 kW.Addition of 1 circuit. residential(with above sq.ft.) 75.00 2 Renewable Energy 0 See Page 2 ',-.. W .;., -' - Services or feeders installation,alteration,and/or relocation Name: Madeleine Tuson-Turner 200 amps or less 100.70 2 Address: 10365 SW Meadow St 201 amps to 400 amps 133.56 2 401 amps to 600 amps 200.34 2 City/State/ZIP:--Tigard Oregon-97223 601a inPs to 1,000 amps 301.04- 2 Phone:((360))317-7400 I Fax:( ) Over 1,000 amps or volts 552.26 2 Temporary services or feeders installation,alteration,and/or Email: tusonturner@gmail.com relocation Owner installation:This installation is being made on property that I own which is not 200 amps or less 59.36 1 intended for sale,lease,rent,or exchange,according to ORS 447,449,670,and 701. 201 amps to 400 amps 125.08 2 Owner signature: Date: 401 amps to 599 amps 168.54 2 r,.;; .. a Branch circuits-new,alteration,or extension,per panel '� ;� �" A.Fee for branch circuits with Business name: ION Developer LLC above service or feeder fee, each branch circuit 7.42 2 Contact name: Dustin Davidson B.Fee for branch circuits without • Address: 44 East 800 North service or feeder fee,first 1 56.18 56.18 2 branch circuit City/State/ZIP: Orem, Utah, 84057 Each add'I branch circuit 7.42 2 Phone: (385)396-4478 I Fax:: Miscellaneous(service or feeder not included) ( ) Each manufactured or modular 67.84 2 Email: dwelling,service and/or feeder permltS@1011SOlar COm Reconnect only 67.84 2 „-il ,4: 1 + ""'_`" w. ,..,Z, ,.-,, . Pump or irrigation circle 67.84 2 Business name: ION Developer LLC Sign or outline lighting 67.84 2 Address: 44 East 800 North Signal circuit(s)or limited-energy panel,alteration,or extension. ❑ See Page 2 2 City/State/ZIP: Orem, Utah,84057 Each additional inspection over allowable in any of the above Additional inspection(1 hr min) 66.25/hr Phone:(385)396-4478 I Fax:( ) Investigation(1 hr min) 90.00/hr Email: permits@ionsolar.com Industrial plant(1 hr min) 78.18/hr Inspections for which no fee is CCB Lic.: 230394 1 Electrical Lic.: C1524 I Suprv.Lic.: 6098S specificall listed %zhrmin 90.00/hr ,i...a .,. gym Suprv.Electrician i Subtotal: 1 56.88 p s gnatilre,required: ,:... Print name: David S Conrad Date: 02-09-2024 0 Plan Review Required(25%of permit fee): State surcharge(12%of permit fee): 18.83 Authorized signature: TOTAL PERMIT FEE: 175.11 •" This permit application expires if a permit is not obtained within 180 Print name: Dustin Davidson Date: 02-09-2024 days after it has been accepted as complete. * Number of inspections allowed per permit. I:\Building\Perntits\ELC_PermitApp_ELR ERE.doc Rev 06/17/2015 440-4615T(11/05/COM/WEB x ocsmmefltRei(1'TFiNS/-aqi /:r, bl'1 6 1Ca6'0 .,x, ... „11� iti , 7 ,. t'.... • Electrical Permit Application-City of Tigard Page 2-Supplemental Information Limited Energy Permit Fees: Renewable Energy Permit Fees: Fee for all residential systems combined: $75.00 °esrr:pn°" Qty E"" Total Renewable electrical energy systems: Check Type of Work Involved: 5 kva or less 1 100.70 100.70 2 5.01to15kva 133.56 2 ❑ Audio and Stereo Systems* 15.01 to 25 kva 200.34 2 Wind generation systems in excess of 25 kva: ❑ Burglar Alarm 25.01 to so kva 301.04 2 ❑ Garage Door Opener* 50.01 to 100 kva 552.26 2 >100 kva(fee in accordance with OAR 918-309-0040) 552.26 2 ❑ Heating,Ventilation and Air Conditioning Solar generation systems in excess of 25 kva: System* Each additional'ma over 25 7.42 , 3 ❑ Vacuum Systems* >100 kva—no additional charge 0.0 3 Each additional inspection over allowable in any of the above: ❑ Other: Each additional inspection is 66.25/hr 1 charged at an hourly(1 hr min) Inspections for which no fee is 90.00/hr specifically listed('/hr min) rpmjnEr vN �., . Fee for each commercial system: $75.00 * allowesubtotal(Enter on Page I): 100 70 (SEE OAR 918-309-0000) Number of inspections d per penult. Check Type of Work Involved: 111 Audio and Stereo Systems - ❑ Boiler Controls ❑ Clock Systems ❑ Data Telecommunication Installation ❑ Fire Alarm Installation ❑ HVAC ❑ Instrumentation ❑ Intercom and Paging Systems ...... ❑ Landscape Irrigation Control* ❑ Medical ❑ Nurse Calls ❑ Outdoor Landscape Lighting* ❑ Protective Signaling Other: Total number of commercial systems: _ *No licenses are required. Licenses are required for all other installations \BuildingTemuts\ELC_PertnitApp_ELR_ERE.doc Rev 06/17/2015 City of Tigard ■ro._ Building Division :11111 '"` 13125 SW Hall Blvd,Tigard,OR 97223 RECEIVED Phone:503.718.2439 Fax: 503.598.1960 FEB 1 T l G A R D Inspection Line: 503.639.4175 �2� www.tigard-or.gov CITY OF TIGARD BUI LDING DIVISION 2010 Oregon Solar Installation Specialty Code Check List for Prescriptive Installation of Roof-Mounted PhotoVoltaic Solar Panel System Property Information Installation Address: 10365 SW Meadow St City: Tigard Zip: 97223 Owner's Name: Madeleine Tuson-Turner Date: 02-09-2024 Contractor's Name: ION Developer LLc CCB #: 230394 Design Parameters of the Property/Structure If"Yes", does not Flood Hazard Is the installation ❑ Yes qualify for the Area Located in a flood prescriptive path, follow plain/flood way? El No OSSC or ORSC for design requirements. Is the wind exposure 0 Yes If"Yes", qualifies for Wind Exposure "C"or less? ❑ No the prescriptive path. Installations on detached Is the Ground Snow single/two-family Load 70 psf or less? dwelling/single/two- If"Yes", qualifies for family townhomes El Yes the prescriptive path. and/or their accessory Ground structures. ❑ No Snow Load Is the Ground Snow Installations on all Load 50 psf or less? structures other than If"Yes", qualifies for ❑ Yes theprescriptive a ,,. path, ❑ No I./Building/Forms/Photovoltaic-Checklist02-01-11.docx 1 4 ° f litiftV-c31i1 '. Is the construction Type of material wood and does Yes the construction qualify If"Yes", qualifies for Construction as "conventional light ❑ No the prescriptive path. frame"construction? Is the spacing 24 inches or less? Pre-engineered trusses. ❑ Yes If"Yes", qualifies for the prescriptive path. ❑ No Roof framing members Is the spacing 24 inches or less? Nominal lumber. If"Yes", qualifies for Yes the prescriptive path. ❑ No Is the combined weight X❑ Yes of the PV modules and If"Yes", qualifies for racking less than or ❑ No the prescriptive path. Solar equal to 4.5 psf? installation Is the solar installation layout in accordance ❑ Yes with Section 305.4(3)of If"Yes", qualifies for the 2010 Oregon Solar 0 No the prescriptive path. Code? ❑ Metal Single layer If roofing material is Roofing Check the type of 0 of wood one of the three types material roofingmaterial shingle/shake checked, qualifies for Max. two layers the prescriptive path. 0 of composition shingle. Is the roof mounted Yes Connections of solar assembly the solar assembly connected to roof If"Yes", qualifies for NO the prescriptive path. to the roof framing or blocking directly? I:/Building/Forms/Photovoltaic-Checklist02-01-11.docx 2 • ❑ Yes If"Yes", qualifies for Is the gauge 26 or less? D No the prescriptive path. 115 lbs for 60 inch spacing or less? If"Yes", qualifies for ❑ Yes the prescriptive path. No Minimum Uplift rating of Clamps? 75 lbs for 48 inches spacing or less? "Yes", qfi Yes the prescriptivualie es path.for ❑ No Attachment of roof mounted Minimum 24 inches If the spacing falls solar systems Spacing of clamps? within 24 inches and 60 directly to inches Maximum 60 inches inches, qualifies for the standing seam prescriptive path. metal panels Width of roofing If the width of the panel is less than 18 panels? 18 inches or less inches - inches qualifies for the prescriptive path. Minimum#10 at 24 inches o/c? Size and spacing of Yes If"Yes", qualifies for fastener? ❑ the prescriptive path. ❑ No Is the roof decking of WSP min.'A"thickness, ❑ Yes decking connected to If"Yes", qualifies for framing members ❑ No the prescriptive path. w/min. 8d nails @ 6"/12"o/c? Is the height less than or Maximum 18 inches equal to 18 inches? Height of the from the top of the If"Yes", qualifies for• solar modules module to the roof Yes the prescriptive path..:,. surface. . ❑ No 3 IlBuilding/Forms/Photovoltaic-Checklist02-01-11.docx Submit `-`cuments re( •d for Prescr'; a Installatio ` how the location of PV system in rela 0 buildings, structure,- ----property lines, and,as applicable, flood hazai "areas. Site Plan Details must be clear and easy to read. Minimum size of the plan is 8.5 x 11 inches. Attach a simple structural plan showing the roof framing(rafter size, type, and spacing) and PV module system racking attachment. System must be shown in sufficient detail and clarity to assess whether it Structural Plan meets the prescriptive construction requirements as listed earlier above in the matrix. Minimum size of the plan is 8.5 x 11 inches. PV Modules Manufacturer: SILFAB Model Number: SIL-420 HC+ Listing Agency: I:/Building/Forms/Photovoltaic-Checklist02-01-11.docx 4 J�i 'J'tg• ii•i0i00ii • :ii'i 'ii i •• _ _ _ _'.$.•; -: .•. !.•p•i:O:ib!•!•!•!•!•!•!•�Clai!e iaei/eli%!i0le!i!e i e!e!.!e!!ti!ii/e! . !%:e..4M..!.i!ive!ei!e-!a�•.i!.i!�.!e e!a..t,...0/e!.!ii!e!e!e�0a.i 1,.1 _41;e,1 :.•.� .❖f r r.> :•.�, •••`• � •••••. 11, Signature-certificate 1 2 2024 ..,. ;.;.; FEB .pp.. '••V Reference number:UTFNV-QKPCA-KNWGE-WUGGNTIGARD �4.•�' ;;.;• BUILDING DMSION :;i.: •••• •,.. 4i Signer Timestamp Signature •!.•:• .., •••, °.' Dustin Davidson I ••• : .::• Email:dustin.davidson@ionsolar.com .• !••0 Peaty,l/� '. %•; Sent: 09 Feb 2024 22:48:41 UTC $ s• !p;•: Signed: 09 Feb 2024 22:48:41 UTC '•, ;•.00. IP address:8.33.47.146 ••; .4 •• !Al.:, Location:Orem,United States •••: P•i .#T.«. ��s_'�^-', ,,,, ,„°;y Y:„.ice' -,& '^` ,` .:r., "" .L-i y,'' " { •••+ .•••;; Document completed by all parties on: ;•;•, '••,•d 09 Feb 2024 22:48:41 UTC _ +❖. !:•i: Page 1 of 1 .;•, :Q•: •••• •••• •• 0•••• •••••• , ... .- 1••1•• ••••.•i !.❖, . • ••. '••••j 'A -•. •..NM •.• ...;•: Signed with PandaDoc ❑ •�• .�.� 4 x,_,.y_ e......+,�.x4rw.Eiva�ukw.rz D �rto..e„.nr. .w.✓w:�: +..w w•il.aN,a+�w?+�"".•wad+ � '*P �'d:.. t - •^ m«ie +weeN• _r•..wr•.c ..tea. •.•.f ., '.,•} PandaDoc i as is workflow and certified eSignature : T• .❖: solution trusted by 50,000+companies worldwide. t !° ;•°•.. •••••. I.••', •p••, :•.•io•e•.�.•• 4•.® sOe•4 ..•• 'O.••a•••!••••e Oe• .• .•e •e•is O_eeesems a �.O•e•••e•••ti.vese4 .e••••1.•.•.•.•'