Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
01-January (5)
CITY OF TIGARD MASTER PERMIT ' ." COMMUNITY DEVELOPMENT Permit• #: MST2024-00021 Date Issued: 01/25/2024 T j GARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Parcel: 2S111A607700 Jurisdiction: Tigard Site address: 9425 SW INEZ ST Subdivision: PENROSE TERRACE Lot: 22 Project: Kling Project Description: Rooftop solar PV system 6.300 kW with (1)200 amp service and (2)branch circuits. BUILDING Floor Areas Required Setbacks Required Stories: 0 Bedrooms: 0 First: 0 sf Basement: 0 sf Left: 0 Parking Spaces: 0 Height: 0 Bathrooms: 0 Second: 0 sf Garage: 0 sf Front: 0 Smoke Dwelling Units: 0 Third: 0 sf Right: 0 Detectors: Total: 0 sf Value: $21,600.00 Rear: 0 PLUMBING Sinks: 0 Water Closets: 0 Washing Mach: 0 Laundry Trays: 0 Rain Drain: 0 Urinals: 0 Lavatories: 0 Dishwashers: 0 Floor Drains: 0 Sewer Lines: 0 SF Rain Drains: 0 Storm Sewer 0 Tubs/Showers: 0 Garbage Disp: 0 Water Heaters: 0 Water Lines: 0 Catch Basins: 0 Bckflw Prevntr: 0 Footing Drain: 0 Ice Maker 0 Hose Bib: 0 Backwater Value: 0 Drywell-Trench Drain: 0 Other Fixtures: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: N Vent Fans: 0 Clothes Dryers: 0 Heat Pump: N Hoods: 0 Other Units: 0 Furn<100K: 0 Vents: 0 Woodstoves: 0 Gas Outlets: 0 Furn>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less: 0 0-200 amp: 1 0-200 amp: 0 W/Svc or Fdr: 2 Ea add!500 sf: 0 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All N Other Y Other Description: Rooftop solar array 6.300 kW Ecompasing: BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: OTR SF VB R-3 0 Owner: Contractor: KLING,CONNIE B EARTHLIGHT TECHNOLOGIES LLC Required Items and Reports(Conditions) 9425 INEZ ST 812 MCCLAINE ST TIGARD,OR 97224 SILVERTON,OR 97381 PHONE: PHONE: (860)871-9700 FAX: Total Fees: $480.59 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. T se rules are set forth in OAR oc')nnl-nnln thrn,inh f1GR oc9-nn1J non V ,,may nhtain a nnntt of fha n!lac nr rliranf nnccfinnc to flu min by Tallinn FfQ 919 10R7 nr 7 1'29 9 d e. .c.� Permittee Issued By: � Signature: 503.639.4175 by 7:00 a.m.for the next available inspectioviiate. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the lob site at the time of each inspection. Building Permit Applicatio> ECEIVE Residential ">JAN 1 1 "7 FOR OFFICE USE ONLY' Cityof Tigard Received g Date/By: �.� '� Permit No.: 'L,y't ",t - ?�•rsJ 13125 SW Hall Blvd.,Tigard,OR 97223 � r a ``t,:e/1 y: l Plan Review II I Phone: 503.718.2439 Fax: 503.598.�p�;;Hn ItN�6 DIVISION/S[�I/'�(�i Other Permit: `JCJI��IIV� ?.J�'1/�47.e„Jt11 Date/By: I�``Z,7 !j� i 1 C A R D Inspection Line: 503.639.4175 Date Ready/By: l�} rt *is: Ea See Page 2 for Internet: www.tigard-or.gov Notified/Method: 1 1 1.I �VM .fiV ) Supplemental Information is , , - g -; ,. �y0 .a s ❑New construction ❑Demolition Permit fees*are based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all X❑Addition/alteration/replacement ❑Other: equipment,materials,labor,overhead,and the profit for the t ' '� 1 , `gx s d, work indicated on this application. k.r: .: .x v,, ,O . so;� y�: i .;, . Valuation: $ 21600.00 ® 1-and 2-family dwelling ❑Commercial/industrial Number of bedrooms: ❑Accessory building El Multi-family0 ❑Master builder III Other: Number of bathrooms: 0 c `: ` ` s, " a 4 , P Total number of floors: qit,.-- .;W,. t,o� .N�,a a.�M+'�t�?{ °wY�.a+ �:"x;:•m��.;w "u�x. ��"� ��'�� .. i .< n Job site address: 9425 SW Inez St New dwelling area: 0 square feet City/State/ZIP: Tigard,OR 97224 Garage/carport area: 0 square feet Suite/bldg./apt.no.: Project name: Covered porch area: 0 square feet Cross street/directions to job site: Deck area: 0 square feet Other structure area: 0 square feet FI'l gym-, e -„ '.,•." fi a l ': 1l . r :a 'c. Subdivision: Lot no.: Permit fees*are based on the value of the work performed. Tax map/parcel no.: Indicate the value(rounded to the nearest dollar)of all equipment,materials,labor,overhead,and the profit for the ` , i " ` ✓ 1 ' > work indicated on this application. Yam. Valuation: $ Prescriptive path roof mounted installation of a 6.300kWp solar system. Existing building area: square feet New building area: square feet A ra '' * ' W l a ', .�# PV Number of stories: Name: Connie Kling Type of construction: Address: 9425 SW Inez St Occupancy groups: City/State/ZIP:Tigard OR 97224 Existing: Phone:( ) Fax:( ) New: a v3 i.,::4 ,. m ";fir ' '"' e)fw ' ): ?... fr 44,174, ag E.,;; ��. Business name: Earthlight Technologies LLC Structural plan review fee(or deposit): Contact name: Elizabeth Winslow FLS plan review fee(if applicable): Address: 812 McClaine St Total fees due upon application: City/State/ZIP: Silverton, OR 97381 ( 503) 874-4142 ( ) Amount received Phone: Fax: a . ;ais. ' , "fie : �" , E-mail: or.ermits • earthli.httech.com # '' ,' 4 "'w* 4; :tom Pi: N s r c Commercial and residential prescriptive installation of ., lx ')11* ';". aVil4+„,.al,,„�,014, &' 1:1 , . s „ ,r ;.. w,�sF ., roof-top mounted Photovoltaic Solar Panel System. Business name: Earthlight Technologies LLC Submit two(2)sets of roof plan with connection details and fire department access,along with the 2010 Oregon Address: 812 McClaine St Solar Installation Specialty Code checklist. City/State/ZIP: Permit Fee(includes plan review Y SIIVerton OR 97381 and administrative fees): $180.00 Phone:(503) 874-4142 Fax:( ) State surcharge(12%of permit fee): $21.60 CCB lie.: 201408 Total fee due upon application: $201.60 Authorized signature: V fi/ r Q�jt, �V Iz w This permit application expires if a permit is not obtained� "'�"' within 180 days after it has been accepted as complete. Print name: Date: *Fcc methodology set by Tri-County Building Industry Elizabeth Winslow 1/10/2024 Service Board. I:ABuilding\Permits\BUP-RESPermitApp.doc 02/24/2011 440-4613T(11/02/COM/WEB) RECEIVED Electrical Permit Application A FOR OFFICE USE ONLY JAN 11 NM Received City Of Tigard Date By: Permit#: vi.1, 17/7.,.4 -:7,0"1 t1-l IIII e 13125 SW Hall Blvd.,Tigard,OR 9722�''`�-�/ Plan Review 2 Phone: 503.718.2439 Fax: 503.598.19FA e D OF TIGARD Date/By: Related Permit S. Inspection Line: 503.639.4175 BUILDING DI'/IS1ON Ready Date/By: Juris. 0 See Page 2 for TIGARL' Internet: www.tigard-or.gov Notified/Method: Supplemental Information € :,fv+cz'•stya�,N t, if v ,:7 v r , '. 'v',,.,b.r.".; " a.',wtvsr. :ze ,t .'l' .1 zz As t1%„�,a v ,% ` i. 'z ag„f"A (: ,"*t F7 ` ,"'yr�a�'�"F:`. x❑New construction ®f Addition/alteration/replacement Please check all that apply(submit 2 sets of plans w/items checked): ❑Service or feeder 400 amps or more ❑Building over three stories. ❑Demolition ❑Other: where the available fault current 0 Marinas and boatyards. ,y„ yz•.,rt 'a'„;„„t,V . ,seizw> of :, t exceeds 10,000 amps at I50 volts or ❑Floating buildings. © 1-and 2-family dwelling ElCommercial/industrial El Accessory less to ground,or exceeds 14,000 ❑Commercial-use agricultural amps for all other installations. buildings. ❑Multi family ❑Master builder ❑Other: ❑Fire pump. 0 Installation of 150 KVA or '`6 t '' f -: 1�x 0 Emergency system. larger separately derived �,�.w3:,�,�r.# r:,"&, n� *,;. .,� ,... . ....,....��„ .,,,,, .; ., ..;�� a�'z��:,..r�if"/r.::. g Y Y P Y Job#: Job site address: 9425 SW in z St ❑Addition of new motor load of system. 100HP or more. ❑"A","F.","I-2","I 3", City/State/ZIP: Tigard,OR 97224 ❑Six or more residential units. occupancy. 0 Health-care facilities. 0 Recreational vehicle parks. Suite/bldg./apt.#: Project name: ❑Hazardous locations. ❑Supply voltage for more than 0 Service or feeder 600 amps or more. 600 volts nominal. Cross street/directions to job site: '-,:\ : '_ —, ,;72 Description Qty. Each Total I% New residential single-or multi-family dwelling unit. Subdivision: Lot#: Includes attached garage. 1,000 sq.ft.or less 168.54 4 Tax map/parcel# Ea.add')500 sq.ft.or portion 33.92 I MIL:401P20,446R1=1:4:aaliZZ, SAIMMItraggabigt Limited energy,residential 75.00 Prescriptive path roof mounted installation of a 6.300kWp solar system (with above sq.ft.) Limited energy,multi-family 75.00 2 residential(with above sq.ft.) / , a. ,. Renewable Energy 0 See Page 2 �`K.r o, 'x� „K °` N�•r. Services or feeders installation,alteration,and/or relocation Name: Connie Kling 200 amps or less 1 100.70 2 Address: 9425 SW Inez St 201 amps to 400 amps 133.56 2 401 amps to 600 amps 200.34 2 City/State/ZIP: Tigard OR 97224 601 amps to 1,000 amps 301.04 2 Phone:( ) Fax:( ) Over 1,000 amps or volts 552.26 2 Temporary services or feeders installation,alteration,and/or Email: relocation Owner installation:This installation is being made on property that I own which is not 200 amps or less 59.36 I intended for sale,lease,rent,or exchange,according to ORS 447,449,670,and 701. 201 amps to 400 amps 125.08 2 Owner signature: Date: 401 amps to 599 amps 168.54 2 y „ " ;r` zt' ,,:: Branch circuits-new,alteration,or extension,per panel A.Fee for branch circuits with Business name: Earthlight Technologies LLC above service or feeder fee, 2 7.42 2 each branch circuit Contact name: Elizabeth Winslow B.Fee for branch circuits without service or feeder fee,first branch circuit Address: 812 McClaine St 56.18 2 City/State/ZIP: Silverton, OR 97381 Each add'l branch circuit 7.42 2 Miscellaneous(service or feeder not included) Phone:(5503) 874-4142 x 3 Fax: :( ) Each manufactured or modular dwelling,service and/or feeder 67.84 2 Email: oreermits•earthli.httech.com Reconnect only 67.84 2 43:.0 is P?, : ii 1t '' . ?,)sx 4� s�..f.�_ � .v����>��' . ,,; s u 4 _ 2 .;:,jl Pump or irrigation circle 67.84 2 Business name: Earthlight Technologies LLC Sign or outline lighting 67.84 2 Signal circuit(s)or limited-energy Address: 812 McClaine St panel,alteration,or extension. ❑ See Page 2 2 Each additional inspection over allowable in any of the above City/State/ZIP: Silverton, OR 97381 Additional inspection(I hr min) 66.25/hr Phone:(503 )874-4142 Fax:( ) Investigation(1 hr min) 90.00/hr Industrial plant(1 hr min) 78.18/hr Email: orpermits©earthlighttech.com Inspections for which no fcc is 90.00/hr CCB Lie.: 201408 Electrical Lie.: C'0995 Suprv.Lie.: 4567S speeiscal) listed('�hr min) T fYl.Ctit • W. , I, Suprv.Electrician signature,required: f. Subtotal: Print name: Timothy Schnieder Date: 01/10/2024 0 Plan Rcvicw Required(25%of permit fee): State surcharge(12%of permit fee): Authorized signature: j� vn4,�'�it f TOTAL PERMIT FEE: This permit application expires if a permit is not obtained within ISO Print name: Elizabeth Winslow Date: 01/10/2024 days after it has been accepted as complete. * Number of inspections allowed per permit. Ic\Building\Pamirs\FTC_PermitApp_EI.R_FRE.doe Rev 06/17'7015 440-4615T(1l/05/COM'WFR Electrical Permit Application—City of Tigard Page 2—Supplemental Information Limited Energy Permit Fees: Renewable Energy Permit Fees: {?fa :`sCv%',*, i Description Qty. Each I Total Fee for all residential systems combined: $75.00 Renewable electrical energy systems: Check Type of Work Involved: 5 kva or less I o0.7o 2 5.01 to 15 kva 1 133.56 2 ❑ Audio and Stereo Systems* 15.01 to 25 kva 200.34 2 Wind generation systems in excess of 25 kva: ❑ Burglar Alarm 25.01 to 50 kva 301.04 2 50.01 to 100 kva 552.26 2 Garage Door Opener* >100 kva(fee iu accordance with OAR 918-309-0040) 552.26 2 ❑ Heating,Ventilation and Air Conditioning Solar generation systems in excess of 25 kva: System* Each additional kva over 25 7.42 3 ❑ Vacuum Systems* >100 kva—no additional charge 0.0 3 Each additional inspection over allowable in any of the above: E Other: Each additional inspection is 6625/hr 1 charged at an hourly(I hr min) Inspections for which no fee is 90.00/hr s ecifically listed('/hr min) 44 s:nla`Vi $75.00 Subtotal(Enter on Page 1): Fee for each commercial system: • Number of inspections allowed per permit. (SEE OAR 918-309-0000) Check Type of Work Involved: ❑ Audio and Stereo Systems ❑ Boiler Controls ❑ Clock Systems ❑ Data Telecommunication Installation ❑ Fire Alarm Installation ❑ HVAC ❑ Instrumentation I I Intercom and Paging Systems ❑ Landscape Irrigation Control* Medical Nurse Calls n Outdoor Landscape Lighting* ❑ Protective Signaling ❑ Other: Total number of commercial systems: *No licenses are required. Licenses are required for all other installations 1:ARulldi*0 Per*t.Ft C_PermitApp_F.t.R_ERE doe Rev 06/17i'015 RECEIVED City of Tigard JAN 1 12024 �� CITY OF TIGARD Building Division 111 13125 SW Hall Blvd,Tigard, OR 97223 BUILDING DIVISION Phone: 503.718.2439 Fax: 503.598.1960 TIGARD inspection Line: 503.639.4175 www.tigard-or.gov 2010 Oregon Solar Installation Specialty Code Check List for Prescriptive Installation of Roof-Mounted PhotoVoltaic Solar Panel System Property Information Installation Address: 9425 sw Inez st City: Tigard Zip: 97224 Owner's Name: Connie Kling Date: 01/10/2024 Contractor's Name: Earthlight Technologies LLC CCB #: 201408 Design Parameters of the Property/Structure If"Yes", does not Is the installation qualify for the Flood Hazard Yes Located in a flood ❑ prescriptive path, follow Area plain/flood way? ❑x No OSSC or ORSC for design requirements. Wind Exposure Is the wind exposure Yes If"Yes", qualifies for "C" or less? ❑ No the prescriptive path. Installations on detached Is the Ground Snow single/two-family Load 70 psf or less? dwelling/single/two- If"Yes", qualifies for family townhomes ❑x Yes the prescriptive path. and/or their accessory Ground structures. ❑ No Snow Load Is the Ground Snow Installations on all Load 50 psf or less? structures other than If"Yes", qualifies for ❑x Yes the prescriptive path. above ❑ No 1 I_/Building/Forms/Photo V oltaic-Checklist02-O 1-1 I.docx , • Is the construction ❑ material wood and does Yes Type of If"Yes", qualifies for the construction qualify Construction as "conventional light El No the prescriptive path. frame" construction? Is the spacing 24 inches or less? If"Yes", qualifies for Pre-engineered trusses. Yes the prescriptive path. n No Roof framing members Is the spacing 24 inches or less? If"Yes", qualifies for ❑ Nominal lumber. Yes the prescriptive path. n No Is the combined weight n Yes of the PV modules and If"Yes", qualifies for racking less than or n No the prescriptive path. Solar equal to 4.5 psf? installation Is the solar installation layout in accordance X Yes with Section 305.4(3) of If"Yes", qualifies for the 2010 Oregon Solar n No the prescriptive path. Code? n Metal Single layer If roofing material is Roofing Check the type of n of wood one of the three types material roofing material shingle/shake checked, qualifies for Max. two layers the prescriptive path. ❑ of composition shingle. Is the roof mounted n Yes Connections of solar assembly If"Yes", qualifies for the solar assembly connected to roof n No to the roof framing or blocking the prescriptive path. directly? 2 I:/Building/Forms/PhotoVoltaic-Checklist02-01-1 1.docx Yes If"Yes", qualifies for Is the gauge 26 or less? No the prescrptive path. 115 lbs for 60 inch spacing or less? If"Yes", qualifies for Yes the prescriptive path. No Minimum Uplift rating of Clamps? 75 lbs for 48 inches spacing or less? If"Yes", qualifies for Yes the prescriptive path. n No Attachment of roof mounted Minimum 24 inches If the spacing falls solar systems Spacing of clamps? within 24 inches and 60 directlyto inches inches, qualifies for the Maximum 60 inches prescriptive path. standing seam metal panels Width of roofing If the width of the panel panels? 18 inches or less is less than 18 inches, inches qualifies for the prescriptive path. Minimum#10 at 24 inches o/c? Size and spacing of If"Yes", qualifies for fastener? n Yes the prescriptive path. n No Is the roof decking of WSP min. '/z"thickness, n Yes decking connected to If"Yes", qualifies for framing members n No the prescriptive path. w/min. 8d nails @ 6"/12"o/c? Is the height less than or Maximum 18 inches equal to 18 inches? Height of the from the top of the If"Yes", qualifies for solar modules module to the roof n Yes the prescriptive path. surface. n No 3 L/Building/Forms/PhotoVoltaic-ChecklistO2-O 1-1 1.docx Submittal Documents required for Prescriptive Installations Show the location of the PV system in relation to buildings, structures, property lines, and, as applicable, flood hazard areas. Site Plan Details must be clear and easy to read. Minimum size of the plan is 8.5 x 11 inches. Attach a simple structural plan showing the roof framing(rafter size, type, and spacing) and PV module system racking attachment. System must be shown in sufficient detail and clarity to assess whether it Structural Plan meets the prescriptive construction requirements as listed earlier above in the matrix. Minimum size of the plan is 8.5 x 11 inches. PV Modules Manufacturer: sunpower Model Number: SPR-x21-350-BLK-E-Ac Listing Agency: uL 4 I:/Building/Forms/Photo V oltaic-Checkl ist02-01-11.docx