Loading...
HomeMy WebLinkAbout10-October (9) CITY OF TIGARD MASTER PERMIT 41 1111 _ COMMUNITY DEVELOPMENT Permit#: MST2023-00533 Date Issued: 11/07/2023 T f c.;AR n 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Parcel: 2S11413B15700 Jurisdiction: Tigard Site address: 16074 SW 103RD AVE Subdivision: RIVERVIEW ESTATES Lot: 3 Project: Aburub Project Description: Rooftop solar system 5.04 kW. BUILDING Floor Areas Required Setbacks Required Stories: 0 Bedrooms: 0 First: 0 sf Basement: 0 sf Left. 0 Parking Spaces, 0 Height: 0 Bathrooms: 0 Second: 0 sf Garage: 0 sf Front: 0 Smoke Dwelling Units: 0 Third: 0 sf Right: 0 Detectors. Total: 0 sf Value: $4.547.09 Rear: 0 PLUMBING Sinks: 0 Water Closets: 0 Washing Mach: 0 Laundry Trays: 0 Rain Drain: 0 Urinals: 0 Lavatories: 0 Dishwashers: 0 Floor Drains: 0 Sewer Lines: 0 SF Rain Drains: 0 Storm Sewer: 0 Tubs/Showers: 0 Garbage Disp: 0 Water Heaters: 0 Water Lines: 0 Catch Basins: 0 Bckflw Prevntr. 0 Footing Drain: 0 Ice Maker: 0 Hose Bib: 0 Backwater Value: 0 Other Fixtures: 0 Drywall-Trench Drain: 0 Other Fixture Units: MECHANICAL Fuel TYPOS Air Conditioning: N Vent Fans: 0 Clothes Dryers: 0 Heat Pump: N Hoods: 0 Other Units: 0 Furn<100K: 0 Vents: 0 Woodstoves: 0 Gas Outlets: 0 Furn>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temo SrvclFeeders Branch Circuits 1000 sf or less 0 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea addl 500 sf: 0 201-400 amp: 0 201-400 amp: 0 W/O SvclFdr: 0 Mfd Home/Feeder/Svc: 0 401-800 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All N Other: Y Other Description: Roof top solar array 5.04 kW Ecompasing. BUILDING INFO Class of Work: Type of Use: Type of Constr. Occupancy Group: Square Feet: OTR SF VB R-3 0 Owner: Contractor: ABURUB,FERAS BRS FIELD OPS LLC Required Items and Reports(Conditions) ABUALRUB,SALAM 1403 NORTH RESEARCH WAY 16074 SW 103RD AVE OREM,UT 84097 TIGARD,OR 97224 PHONE: PHONE: 855-205-2530 FAX: Total Fees: $351.19 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 160 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR oc9-nnt-onto rhrry. 'IAR 05 not non mirk' rnnv of*ha n Jac nr rlirart nune'inn"n ni MC hw rneinn c02 929 10A7 nr 1 Ann 229 92dd e e If, I . rcc'� i Aa1-1 Issued By: Permittee Signature: 503.639.4175 by 7 r 0 a,m.for the next available Inspection date. This permit card shall be kept In a conspicuous place on the Job site until completion of the project. Approved plans are required on the lob site at the time of each inspection. f 'Building Permit Application Residential RECEIVED FOR OFFICE USE ONLY City of Tigard Received DateBy: el 3a ?3 , Permi .'6�/��{ OV r —C°9 2023 III • 13125 SW Hall Blvd.,Tigard,OR 97223 SEP 3 0 Plan Review Phone: 503.718.2439 Fax: 503.598.1960 DateBy: 10// 2, Other Permit: I ,A�,t� Inspection Line: 503.639.4175 CITY OF TIGARD Date Ready/By: ((( 13 Jail fa See Page 2 for Internet: wk�v.tigard-or.gov BUILDING DIVISION Notified/Method: I"J 3 f -)3 , 7 Supplemental Information TYPE OF WORK REQUIRED DATA:1-AND 2-FAMILY DWELLING ❑ New construction D Demolition Petmit fees*are based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all O Addition/alteration/replacement ❑Other: equipment materials,labor,overhead,and the profit for the CATEGORY'OF CONSTRUCTION work indicated on this application. Valuation: $ 4,547.09 ❑ 1-and 2-family dwelling ❑Commercial/industrial ElAccessory building ID Multi-family Number of bedrooms: ❑Master builder ❑Other: Number of bathrooms: JOB SITE INFORMATION AND LOCATION Total number of floors: Job site address: 16074 Sw 103rd Ave,Tigard, Oregon,97224 New dwelling area: square feet City/State/ZIP: Garage/carport area: square feet Suite/bldg./apt.no.: Project name: Feras M Aburub Covered porch area: square feet Cross street/directions to job site: Deck area: square feet Other structure area: square feet REQUIRED DATA:COMMERCIAL-USE CHECKLIST Subdivision: Lot no.: Permit fees*are based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all Tax mapiparcel no.: equipment,materials,labor,overhead,and the profit for the DESCRIPTION OF WORK work indicated on this application. Rooftop Solar PV 6,0t4 1J: tV,) Valuation: S " Existing building area: square feet New building area: square feet ® PROPERTY OWNER [] TENANT Number of stories: Name: Feras M Aburub Type of construction: Address: 16074 Sw 103rd Ave,Tigard,Oregon,97224 Occupancy groups: City/State/ZIP: Existing: Phone:( ) Fax:( I New: 0 APPLICANT ® CONTACT PERSON BUILDING PERMIT FEES* (Please refer to fee scheduler Business name: BRS Field Ops, LLC Structural plan review fee(or deposit): Contact name: Diana Sanchez FLS plan review fee(if applicable): Address: 1403 N Research Way Total fees due upon application: City/State/ZIP: Orem, UT 84097 Amount received: Phone:( 385)482-0045 Fax::( ) E-mail: permitting.deparment@blueravensolar.com PHOTOVOLTAIC SOLAR PANEL SYSTEM FEES* Commercial and residential prescriptive installation of CONTRACTOR roof-top mounted PhotuVoltaic Solar Panel System. Business name: BRS Field Ops, LLC Submit two(2)sets of roof plan with connection details and fire department access,along with the 2010 Oregon Address: 1403 N Research Way Solar Installation Specialty Code checklist. City/State/ZIP: Orem, UT 84097 Permit Fee(includes plan review $180.00 and administrative fees): Phone:( 385)482-0045 Fax:( ) State surcharge(12%of permit fee): $21.60 CCB Iic.: 227185 Total fee due upon application: $201.60 Authorized signature: 22142442 / This permit application expires if a permit is not obtained _(rr1Pi/a,b ee Permitting Coordinator within 180 days after it has been accepted as complete. Print name: Diana Sanchez lli4f4CrlrrlLL4� Date: 09 1 28/2023 *Fee methodology set by Tri-County Building Industry Service Board. I:\Building\PemiltstBUP-RESPennitApp.doc 02/24/2011 440-4613T(11/02/COMIWEB) " Electrical Permit Application FOR OFFICE USE ONLY Received City of Tigard• RecDateive Perm ��9�—Ctc 1 13125 SW Hall Blvd.,Tigard,OR 97223 Plan Review Phone: 503.718.2439 Fax: 503.598.1960 Date/By: Related Permit W. Inspection Line: 503.639.4175 Ready Date/By: runs: lig See Page 2 for T I G AR D r Internet: www.tigard-ongov Notified/Method: Supplemental Information TYPE OF WORK PLAN REVIEW ❑New construction el Addition/alteration/replacement Please check all that apply(submit 2 sets of phuu w/items checked): ❑Service or feeder 400 amps or more ❑Building over three stories. ❑Demolition ❑Other: where the available fault current 0 Marinas and boatyards. CATEGORY OF CONSTRUCTION exceeds 10,000 amps at 150 volts or 0 Floating buildings. O 1-and 2-family dwelling ❑Commercial/industrial ❑Accessory building less to ground,or exceeds 14,000 0 Commercial-use agricultural amps for all other installations. buildings. ❑Multi-family ❑Master builder ❑Other: 0 Fire pump. ❑Installation of 150 KVA or JOB SITE INFORMATION AND LOCATION 0 Emergency system. larger separately derived ❑Addition of new motor load of system. Job#: Job site address: 16074 Sw 103rd Ave,Tigard, Oregon, 97224 I00HP or more. ❑ `A","E", '1-2',°'1-3", O Six or more residential[mils. occupancy. City/State/ZIP: ❑Health-care facilities. 0 Recreational vehicle parks. Suite/bldg./apt.#: Project name: Feras M Aburub ❑Hazardous locations. 0 Supply voltage for more than ❑Service or feeder 600 amps or more. 600 volts nominal. Cross street/directions to job site: FEE SCHEDULE Description I Qty. I Each I Total I * New residential single-or multi-family dwelling unit. Subdivision: Lot#: Includes attached garage. 1,000 sq.ft.or less 168.54 4 Tax map/parcel#: Ea.add'!500 sq.ft.or portion 33.92 1 DESCRIPTION OF WORK Limited energy,residential 75.00 2 Rooftop Solar PV (with above sq.ft.) Limited energy,multi-family 75.00 2 residential(with above sq.f..) Renewable Energy ❑ See Page 2 ®PROPERTY OWNER ❑ TENANT Services or feeders installation,alteration,and/or relocation Name: Feras M Aburub 200 amps or less 100.70 2 Address: 16074 Sw 103rd Ave,Tigard,Oregon,97224 201 amps to 400 amps 133.56 2 401 amps to 600 amps 200.34 2 City/State/ZIP: 601 amps to 1,000 amps 301.04 2 Phone:( ) Fax: ( ) Over 1,000 amps or volts 552.26 2 Temporary services or feeders installation,alteration,and/or Email: relocation Owner installation:This installation is being made on property that I own which is not 200 amps or less 59.36 1 intended for sale,lease,rent,or exchange,according to ORS 447.449.670.and 701. 201 amps to 400 amps 125.08 2 Owner signature: Date: 401 amps to 599 amps 168.54 2 ® APPLICANT ❑ CONTACT PERSON Branch circuits—new,alteration,or extension,per panel A.Fee for branch circuits with Business name: BRS Field Ops, LLC above service or feeder fee, 7.42 2 each branch circuit Contact name: Diana Sanchez B.Fee for branch circuits without service or feeder fee,first 56.18 2 Address: 1403 N Research Way branch circuit City/State/ZIP: Orem, UT 84097 Each add'!branch circuit 7.42 2 Miscellaneous(service or feeder not included) Phone:( 385)482-0045 Fax: : ( ) Each manufactured or modular 67.84 2 dwelling,service and/or feeder Email: Permittin •de artment blueravensolarcom Reconnect only 67.84 2 CONTRACTOR Pump or irrigation circle 67.84 2 Business name: BRS Field Ops, LLC Sign or outline lighting 67.84 2 Signal circuit(s)or limited-energy ❑ See Page 2 2 Address: 1403 N Research Way panel,alteration,or extension. City/State/ZIP: Orem, UT 84097 Each additional inspection over allowable in any of the above Additional inspection(1 lm min) 66.25/hr Phone:( 385) 482-0045 Fax:( ) Investigation(1 hr min) 90.00/hr Industrial plant(1 hr mint) 78.18/hr Email: permitting.department@blueravensolar.com Inspections for which no fee is 90.00/hr CCB Lie.: 227185 Electrical Lc.: C1493 Suprv.Lic.: 6394S specifically listed(i's hr min) ELECTRICAL PERMIT FEES Suprv.Electrician signature,required: tai4 Subtotal: Print name: Shan Whittaker Date: 09/28/2023 0 Plan Review Required(25%of permit fee): State surcharge(12%of permit fee): • Authorized signature: ?ta a vQachee Permitting Coordinator TOTAL PERMIT FEE: This permit application expires if a permit is not obtained within 16a Print name: Diana Sanchez Date: 09/28/2023 days after it has been accepted as complete. * Number of inspections allowed per permit. l:lBnilding\Permits\ELC PermitApp_ELR_ERE.doe Rev 06i17i2015 440-46151(11i051COWWEB M - y, Electrical Permit Application—City of Tigard Page 2—Supplemental Information Limited Energy Permit Fees: Renewable Energy Permit Fees: RESIDENTIAL WORK ONLY: FEE SCHEDULE Descri • Fee for all residential systems combined: $75.00Renewable I Qty.m : F I Total I y electrical energy systems: Check Type of Work Involved: 5 kva orless 100.70 2 5.01 to 15 kva 133.56 2 ❑ Audio and Stereo Systems* 15.01 to 25 kva 200.34 2 Wind generation systems in excess of 25 kva: ❑ Burglar Alarm 25.01 to 50 kva 301.04 2 I] Garage Door Opener* 50.01 to 100 kva 552.26 2 >100 kva(fee in accordance 552.26 2 with OAR 918-309-0040) ❑ Heating, Ventilation and Air Conditioning Solar generation systems in excess of 25 kva: System* Each additional kva over 25 7,42 3 ❑ Vacuum Systems* >100 kva-no additional charge 0.0 3 Each additional inspection over allowable in an_of the above: ❑ Other: Each additional inspection is 66.25/hr l charged at an hourly(1 hr min) Inspections for which no fee is specifically listed(t hr min) 90.00/hr COMMERCIAL WORK ONLY: ELECTRICAL PERMIT FEES Fee for each commercial system: $75.00 allows at(Enter on Page 1): (SEE OAR 918-309-0000) Number of inspections ll"wed per permit. Check Type of Work Involved: ❑ Audio and Stereo Systems ❑ Boiler Controls ❑ Clock Systems ❑ Data Telecommunication Installation ❑ Fire Alarm Installation ❑ HVAC ❑ Instrumentation n Intercom and Paging Systems n Landscape Irrigation Control* ❑ Medical ❑ Nurse Calls ❑ Outdoor Landscape Lighting* ❑ Protective Signaling ❑ Other: Total number of commercial systems: *No licenses are required. Licenses are required for all other installations I:1Buildinecrmitaflc_PermitApp_ELR ERti.doc Rev 06/17/2015 City of Tigard RECEIVED " Building Division SEP 3 n 13125 SW Hall Blvd,Tigard,OR 97223 2013 Phone: 503.718.2439 Fax: 503.598.1960 CITY OF TIGARD TIGARD Inspection Line: 503.639.4175 BUILDING DIVISION www.tigard-or.gov 2010 Oregon Solar Installation Specialty Code Check List for Prescriptive Installation of Roof-Mounted PhotoVoltaic Solar Panel System Property Information Installation Address: 16074 Sw 103rd Ave, Tigard, Oregon, 97224 City: Zip: Owner's Name: Feras M Aburub Date: 09 / 28 / 2023 Contractor's Name: BRS Field Ops, LLC CCB #: 227185 Design Parameters of the Property/Structure If"Yes", does not Flood Hazard Is the installation ❑ Yes qualify for the Located in a flood prescriptive path, follow Area plain/flood way? © No OSSC or ORSC for design requirements. Wind Exposure Is the wind expsure 0 Yes If"Yes", qualifies for "C"or less? ❑ No the prescriptive path. Installations on detached Is the Ground Snow single/two-family Load 70 psf or less? dwelling/single/two- If"Yes", qualifies for family townhomes © Yes the prescriptive path. and/or their accessory Ground structures. ❑ No Snow Load Is the Ground Snow Installations on all Load 50 psf or less? If"Yes", qualifies for structures other than © Yes the prescriptive path. above ❑ No 1 I:Building/Fortes/PhotoVoltaic-Checldist02-01-11.docx Is the construction material wood and does 0 Yes Type of If"Yes", qualifies for the construction qualify Construction as "conventional light ❑ No the prescriptive path. frame" construction? Is the spacing 24 inches or less? Pre-engineered trusses. ❑ Yes If Yes,>, qualifies for the prescriptive path. ❑ No Roof framing members Is the spacing 24 inches or less? Nominal lumber. If"Yes", qualifies for ❑ Yes the prescriptive path. ❑ No Is the combined weight 0 Yes of the PV modules and If"Yes", qualifies for racking less than or ❑ No the prescriptive path. Solar equal to 4.5 psf? installation Is the solar installation layout in accordance Yes with Section 305.4(3) of If"Yes", qualifies for the 2010 Oregon Solar ❑ No the prescriptive path. Code? ❑ Metal Single layer If roofing material is Roofing Check the type of ❑ of wood one of the three types material roofing material shingle/shake checked, qualifies for Max. two layers the prescriptive path. ❑v of composition shingle. Is the roof mounted 0 Yes Connections of solar assembly If"Yes", qualifies for the solar assembly connected to roof ❑ No the prescriptive path. to the roof framing or blocking directly? 2 C/Building/Forms/Photo Voltaic-Checklist02-01-11.docx Is the gauge 26 or less? ❑ Yes If"Yes", qualifies for ❑ No the prescriptive path. 115 lbs for 60 inch spacing or less? If"Yes", qualifies for ❑ Yes the prescriptive path. ❑ No Minimum Uplift rating of Clamps? 75 lbs for 48 inches spacing or less? If"Yes", qualifies for ❑ Yes the prescriptive path. ❑ No Attachment of roof mounted Minimum 24 inches If the spacing falls solar systems Spacing of clamps? within 24 inches and 60 directly to inches Maximum 60 inches inches, qualifies for the prescriptive path. standing seam metal panels Width of roofing If the width of the panel panels? 18 inches or less is less than 18 inches, inches qualifies for the prescriptive path. Minimum#10 at 24 inches o/c? Size and spacing of If"Yes", qualifies for fastener? ❑ Yes the prescriptive path. ❑ No Is the roof decking of WSP min. 'h"thickness, ❑ Yes decking connected to If"Yes", qualifies for framing members ❑ No the prescriptive path. w/min. 8d nails @ 6"/12" o/c? Is the height less than or Maximum 18 inches equal to 18 inches? Height of the from the top of the If"Yes", qualifies for solar modules module to the roof Yes the prescriptive path. surface. ❑ No 3 1:B u ilding/Forms/Photo V oltaic-Checklist02-01-l 1.docx . . Submittal Documents required for Prescriptive Installations Show the location of the PV system in relation to buildings, structures, property lines, and, as applicable, flood hazard areas. Site Plan Details must be clear and easy to read. Minimum size of the plan is 8.5 x 11 inches. Attach a simple structural plan showing the roof framing (rafter size, type, and spacing) and PV module system racking attachment. System must be shown in sufficient detail and clarity to assess whether it Structural Plan meets the prescriptive construction requirements as listed earlier above in the matrix. Minimum size of the plan is 8.5 x 11 inches. PV Modules Manufacturer: REC Solar Model Number: REC420AA PURE-R Listing Agency: UL 4 1:Building/Forms/Photo V oltaic-Checklist02-01-11.docx