Loading...
BUP2022-00098 � � AT&T D - .r OFFICE COP AT&TC .vt _I_ �; IN OF TIGARD AT&T SITE NUv13E�: P�77 BUSINESS U\ IT #: 856366 3UILDINGDIVISION CROWN AT&T SITE NAv1E: SCHOLLS & 125TH SITE ADDS ESS: 12655-A SOUTHWEST NORTH DAKOTA STRECICCASTLETTLE NORTH,SUITE ECU AT&T FA CODE: 10098014 TIGARD, OR 97223 SEATTLE WA98109 AT&T PACE NU v 3 E : MRW0R054072 / MRW0R057860 COUNTY: WASHINGTON o SITE TYPE: v10 \ OPOLE JURISDICTIO\ : CITY OF TIGARD `oD. TWR/FAA APPROVED HGT: 55.0'/\ot Listed P. MARSHALL&ASSOCIATES DROJECT: 5G \ 1 SR n77 BdP2D2.2."060g6- SITE INFORMATION DRAWING INDEX LOCATION MAP D 77 CROWN CASTLE USA INC. SCHOLLS & 125TH SHEET # SHEET DESCRIPTION 8U #: 856366 SITE NAME: Southridge High School SITE ADDRESS: 12655-A SOUTHWEST NORTH DAKOTA STREET T-1 TITLE SHEET & PROJECT INFORMATION . SCROLLS & 125TH TIGARD, OR 97223 T-2 GENERAL NOTES SOUTH Din Tai Fung COUNTY: WASHINGTON 12655—A SOUTHWEST NORTH MAP/PARCEL#: R2032709 C-1.1 OVERALL SITE PLAN B E A V E R T O N 9 C-1.2 EXISTING & FINAL EQUIPMENT PLANS DAKOTA STREET AREA OF CONSTRUCTION: EXISTING in C-2 EXISTING & FINAL ELEVATIONS TIGARD, OR 97223 LATITUDE: 45- 26' 32.07" (45.4422416667) C-3 EXISTING & FINAL ANTENNA PLANS 5` LONGITUDE: -122' 48' 16.20" (-122.8045) C-4 ANAL ANTENNA & CABLE SCHEDULE N World Mark( LAT/LONG TYPE: (NAD 83) C-5 ELECTRICAL WIRING DIAGRAM CURRENT ZONING: C-P C-6 EQUIPMENT DETAILS > JURISDICTION: CITY OF TIGARD C-7 EQUIPMENT DETAILS < OCCUPANCY CLASSIFICATION: U C-8 EQUIPMENT DETAILS m REV DATE DESCRIPTION TYPE OF CONSTRUCTION: IIB A 1/21/22 PRELIMS A.D.A. COMPLIANCE: FACILITY IS UNMANNED AND NOT FOR HUMAN G-1 GROUNDING SCHEMATIC Whole Foods M 9 V) HABITATION G-2 GROUNDING DETAILS 9 Safeway qa 0 3/24/22 FOR CONSTRUCTION OWNER:- PROPERTY GLOBAL SIGNAL ACQUISITIONS IV, LLC ATTACHED PLUMBING DIAGRAM t� 12655-A SOUTHWEST NORTH DAKOTA 9 Sterling Pointe �' - -- -- TIGARD, OR 97223 Apartments < v TOWER OWNER: 2000 CORPORATE CASTLE SA Inc 9 .DRIVE S 3 CANONSBURG, PA 15317 J¢ Li"PROJECT DESCRIPTION CARRIER APPLICANT: AT&T TOWER ASSET GROUP Walgreens Summerlake ,c, 19801 SW 72ND AVENUE THE PURPOSE OF THIS PROJECT IS TO PROPOSE AN ANTENNA • TUALATIN, OR 97062 MODIFICATION ON AN EXISTING WIRELESS SITE. City Park ae� • TOWER SCOPE OF WORK �`cl' Both LTE & NR must be on the same CPRI Rate7. 1st LTE CPRI - ro should be SFP7 (NE0.20022) on both Radio and ABIA sides for Dirksen AirScale RRH (AHLBA, AHLBBA, AHFIB, AHCA, AHNA) and SFP7 (CEQ.16446 or NEQ.20022) on both Radio and ARIA sides for GU'--'gle Nature Park Map data©2021 ALU radios (UREA, UHIE). The 2nd 5G CPRI should be SFP7 (NE0.20022/NEQ.53020) on both Radio and ABIL/ABIO sides for NO SCALE Airscale and ALU radios. Add 2nd CPRI connection for all PROJECT TEAM bands/radio that is missing. n77 Bond requires (2) CPRI connections (CEQ.24407) on both Radio and ABIO sides. APPLICABLE CODES/REFERENCE DOCUMENTS A&E FIRM: P. MARSHALL & ASSOCIATES Contractor to maintain RRH to back of antenna clearance and DESIGNED:JLB 1000 HOLCOMB WOODS PKWY STE. 210 814/B29 & n77 antenna separation per latest AT&T guidelines. ALL WORK SHALL BE PERFORMED AND MATERIALS INSTALLED IN ACCORDANCE REFERENCE DOCUMENTS: DRAWN: JLB ROSWELL, GA 30076 • REMOVE (6) ANTENNAS WITH THE CURRENT EDITIONS OF THE FOLLOWING CODES AS ADOPTED BY THE RFDS ID: 4340407 PATRICK W MARSHALL, P.E. • INSTALL (9) ANTENNAS LOCAL GOVERNING AUTHORITIES. NOTHING IN THESE PLANS IS TO BE CONSTRUED APPLICATION ID: 569671 CHECKED: PWM 678-280-2325 • INSTALL (2) #6 AWG DC TRUNKS TO PERMIT WORK NOT CONFORMING TO THESE CODES: CODE TYPE CODE MOUNT ANALYSIS BY: INFINIGY CROWN CASTLE USA 1505 WESTLAKE AVENUE NORTH, SUITE 800 GROUND SCOPE OF WORK BUILDING 2019 OSSC JOB #: INC. DISTRICT: SEATTLE, WA 98109 • REMOVE (2) BATTERY CABINETS MECHANICAL 2019 OMSC DATED: 1/14/22 ,r,,',=' 21 CCA06M-0141 CONTACTS: JASON GIBSON - PROJECT MANAGER • REMOVE +24v DC POWER PLANT ELECTRICAL 2020 OESC exRiRss: s/ao/aoaz (615) 771-4313 • REMOVE POWER EQUIPMENT FROM EXISTING CONVERTER FIRE 2019 OFC PAUL LONG - CONSTRUCTION MANAGER SHELF, REMOVE CONVERTER SHELF; TRANSFER LOADS TO NEW • POWER PLANT (206) 388-9090 • INSTALL -48V EMERSON NETSURE 512 DC PLANT W/ (11) Thisaub,nimiuncontainseonfdentlet,propelebry,erWadeseeretInormatioet.tk TITLE SHEET & RECTIFIERS & (2) CONVERTER MODULES swamps from disclosure under applicable laws.Plasm make sun then pages era not ROBERT FOREST - A&E SPECIALIST • INSTALL EMERSON BATTERY CABINET disclosed.If any request Is made for this information,pleas*contact the sender in PROJECT • (917) 924-7092 • RECONFIGURE (16) +24V STRINGS AS (8) -48V STRINGS additlonmanYlegelnotlaregWramentsundarappllublolaw. INFORMATION AT&T CONTACT: TIM DOLLOWITCH • EXISTING FSM4 (AMIA) - REMOVE EXISTING (1) ASIK AND (1) n«e",us••.aeeer.•rsc rw.ee",•m does•m ra,mme ams rromeeceq cre ndesy„ 19801 SW 72ND AVENUE ABIL CARDS ON THE C2 SIDE. ADD (1) ASIL AND (3) ABIO CALL OREGON ONE CALL TUALATIN, OR 97062 CARDS TO THE C2 SIDE FOR 5G 850/1900/AWS, 5G C n77 a (503) 569-7818 & 5G C n77 clod NOTE (&:), �® (800)332-2344 811; (503)lloeitc usconsultin net PRIOR TO ACCESSING/ENTERING THE SITE YOU MUST CONTACT THE CROWNtim.d ., CALL 3 WORKING DAYS 9 NOC AT (800) 788-7011 & CROWN CONSTRUCTION MANAGER -=-10%T Ts*1 BEFORE YOU DIG! CROWN CASTLE USA INC. SITE AC11VITY REQUIREMENTS: GENERAL NOTES: ELECTRICAL INSTALLATION NOTES: 411110 1. FOR THE PURPOSE OF CONSTRUCTION DRAWING,THE FOLLOWING DEFINITIONS SHALL APPLY: I. NOTICE TO PROCEED- NO WORK SHALL COMMENCE PRIOR TO CROWN CASTLE USA INC.WRITTEN NOTICE TO PROCEED(NTP) CONTRACTOR. GENERAL CONTRACTOR RESPONSIBLE FOR CONSTRUCTION 1. ALL ELECTRICAL WORK SHALL BE PERFORMED IN ACCORDANCE'HRH THE PROJECT SPECIFICATIONS, NEC AND ALL APPLICABLE FEDERAL.STATE,AND AND THE ISSUANCE OF A PURCHASE ORDER. PRIOR TO ACCESSING/ENTERING THE SITE YOU MUST CONTACT THE CROWN CARRIER: AT&T LOCAL CODES/ORDINANCES. CASTLE USA INC. NOC AT 800-788-7011 &THE CROWN CASTLE USA INC.CONSTRUCTION MANAGER. TOWER OWNER, CROWN CASTLE USA INC. 2. CONDUIT ROUTINGS ARE SCHEMATIC.CONTRACTOR SHALL INSTALL CONDUITS SO THAT ACCESS TO EQUIPMENT IS NOT BLOCKED AND TRIP HAZARDS ARE �-- / AT&T 2. 'LOOK UP"-CROWN CASTLE USA INC.SAFETY CLIMB REQUIREMENT: 2. THESE DRAWINGS HAVE BEEN PREPARED USING STANDARDS CF PROFESSIONAL CARE AND COMPLETENESS NORMALLY EXERCISED UNDER ELIMINATED. V THE INTEGRITY OF THE SAFETY CLIMB AND ALL COMPONENTS OF THE CLIMBING FACILITY SHALL BE CONSIDERED DURING ALL SIMILAR CIRCUMSTANCES BY REPUTABLE ENGINEERS IN THIS DR SIMILAR LOCALITIES. IT 15 ASSUMED THAT THE WORK DEPICTED WILL BE 3. WIRING, RACEWAY AND SUPPORT METHODS AND MATERIALS SHALL COMPLY WITH THE REQUIREMENTS OF THE NEC. STAGES OF DESIGN,INSTALLATION,AND INSPECTION.TOWER MODIFICATION,MOUNT REINFORCEMENTS,AND/OR EQUIPMENT PERFORMED BY AN EXPERIENCED CONTRACTOR AND/OR WORKPEOPLE WHD HAVE A WORKING KNOWLEDGE OF THE APPLICABLE CODE 4. ALL CIRCUITS SHALL BE SEGREGATED AND MAINTAIN MINIMUM CABLE SEPARATION AS REQUIRED BY THE NEC. '- INSTALLATIONS SHALL NOT COMPROMISE THE INTEGRITY OR FUNCTIONAL USE OF THE SAFETY CLIMB OR ANY COMPONENTS OF STANDARDS AND REQUIREMENTS AND OF INDUSTRY ACCEPTED STANDARD GOOD PRACTICE. AS NOT EVERY CONDITION OR ELEMENT IS(OR 4.1. ALL EQUIPMENT SHALL BEAR THE UNDERWRITERS LABORATORIES LABEL OF APPROVAL,AND SHALL CONFORM TC REQUIREMENT OF THE NATIONAL THE CLIMBING FACILITY ON THE STRUCTURE.THIS SHALL INCLUDE, BUT NOT BE LIMITED TO: PINCHING OF THE WIRE HOPE, CAN BE) EXPLICITLY SHOWN ON THESE DRAWINGS,THE CONTRACTOR SHALL USE INDUSTRY ACCEPTED STANDARD GOOD PRACTCE FOR ELECTRICAL CODE. BENDING OF THE WIRE ROPE FROM ITS SUPPORTS, DIRECT CONTACT OR CLOSE PROXIMITY TO THE WIRE ROPE WII'.CH MAY MISCELLANEOUS WORK NOT EXPLICITLY SHOWN. 4.2. ALL OVERCURRENT DEVICES SHALL HAVE AN INTERRUPTING CURRENT RATING THAT SHALL BE GREATER THAN THE SHORT CIRCUIT CURRENT TO CAUSE FRICTIONAL WEAR, IMPACT TO THE ANCHORAGE POINTS IN ANY WAY.OR TO IMPEDE/BLOCK ITS INTENDED USE.ANY 3. THESE DRAWINGS REPRESENT THE FINISHED STRUCTURE. THEY DO NOT INDICATE THE MEANS OR METHODS OF CONSTRUCTION. THE WHICH THEY ARE SUBJECTED, 22,000 VIC MINIMUM.VERYIFY AVAILABLE SHORT CIRCUIT CURRENT DOES NOT EXCEED THE RATING OF ELECTRICAL ., COMPROMISED SAFETY CLIMB, INCLUDING EXISTING CONDITIONS MUST BE TAGGED OUT AND REPORTED TO YOUR CROWN CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR THE CONSTRUCTION MEANS.METHODS.TECHNIQUES,SEQUENCES,AND PROCEDURES. EQUIPMENT IN ACCORDANCE WITH ARTICLE 110.24 NEC OR THE MOST CURRENT ADOPTED CODE PRE THE GOVERNING JURISDICTION. _ , _ CASTLE USA INC. POC OR CALL THE NOC TO GENERATE A SAFETY CLIMB MAINTENANCE AND CONTRACTOR NOTICE TICKET. THE CONTRACTOR SHALL PROVIDE ALL MEASURES NECESSARY FOR PROTECTION OF LIFE AND PROPERTY DURING CONSTRUCTION. SUCH 5. EACH END OF EVERY POWER PHASE CONDUCTOR.GROUNDING CONDUCTOR,AND TELCO CONDUCTOR OR CABLE SHALL BE LABELED WITH ,' ,A CROWN 3. PRIOR TO THE START OF CONSTRUCTION, REQUIRED PERMITS BE OBTAINED.THIS NCLUDES.' BUT MEASURESTATIVEL INCLUDE. UTNOT INSPECTION N BE LIMITED TO,BRACING,FORMWORK.SHORING,LTC. SITE VISITS BY THE ENGINEER OR HIS COLOR-CODED INSULATION OR ELECTRICAL TAPE(3M BRAND, 1/2"PLASIIC LLLCIRICAL TAPE WI!H UV PROTECTION,OR EQUAL). THE IDENTIFICATION .Y IS NOT LIMITED A BUR DING, ELECTRICAL,ALL MECHANICAL,QUIRE FIRE,JURISDICTIONAL ZONE, ITSIRQN SHALLLNBE AND ZONING.. AFTER ONSITE WILLINCLUDE S EC ION OF THESE ITEMS AND IS FOR STRUCTURAL OBSERVATION OF THE FINISHED STRUCTURE METHOD SHALL CONFORM WITH NEC AND OSHA. CAST L E IS TIES AND TO,CONSTRUCTIONBURARE COMPLETED,ALL REQUIRED PERMITS SHALLENVIRONMENTAL, BE SATISFIED AND CLOSED OUT ACCORDINGONSITE ONLY. 6. ALL ELECTRICAL COMPONENTS SHALL BE CLEARLY LABELED WITH LAMICOID TAGS SHOWING THEIR RATED VOLTAGE,PHASE CONFIGURATION,WIRE TOA LOCAL JURISDICTIONAL REQUIREMENTS. 4, NOTES AND DETAILS IN THE CONSTRUCTION DRAWINGS SHALL TAKE PRECEDENCE OVER GENERAL NOTES AND TYPICAL DETAILS. WHERE NO CONFIGURATION,POWER OR AMPACITY RATING AND BRANCH CIRCUIT ID NUMBERS (i.e. PANEL BOARD AND CIRCUIT ID'S). 4. ALL CONLTJURSDI MEANS AND RMETEODS; INCLUDING BUT NOT LIMITED i0,ERECTION PUNS,RIGGING PLANS,CLIMBING DETAILS ARE SHOWN,CONSTRUCTION SHALL CONFORM TO SIMILAR WORK ON THE PROJECT,AND/OR AS PROVIDED FOR IN THE CONTRACT 7. PANEL BOARDS(ID NUMBERS)SHALL BE CLEARLY LABELED WITH PLASTIC LABELS. '1.505 WESTLAKE AVENUE NORTH,SUITE 800 DOCUMCNTS. WHERE DISCREPANCIES OCCUR BETWEEN PLANS, DETAILS,GENERAL NOTES,AND SPECIFICATIONS,THE GREATER,MORE STRICT 8. ALL TIE WRAPS SHALL BE CUT FLUSH WITH APPROVED CUTTING TOOL TO REMOVE SHARP EDGES. PUNS,AND RESCUE PLANS SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR RESPONSIBLE FOR THE EXECUTION REQUIREMENTS,SHALL GOVERN. IF FURTHER CLARIFICATION:5 REQUIRED CONTACT THE ENGINEER OF RECORD. 9. ALL POWER AND EQUIPMENT GROUND'WIRING IN TUBING OR CONDUIT SHALL BE SINGLE COPPER CONDUCTOR(#14 OR LARGER)WITH TYPE THHW. SEATTLE,W A 981 C9 OF THE WORK CONTAINED HEREIN,AND SHALL MEET ANSI/ASSE A10.48(LATEST EDITION);FEDERAL,STATE.AND LOCAL 5. SUBSTANTIAL EFFORT HAS BEEN MADE TO PROVIDE ACCURATE DIMENSIONS AND MEASUREMENTS ON THE DRAWINGS TO ASSIST IN THE THWN,THWN-2, XHHW, XHHW-2,THW,THW-2,RHW,OR RHW-2 INSULATION UNLESS OTHERWISE SPECIFIED. REGULATIONS;AND ANY APPLICABLE INDUSTRY CONSENSUS STANDARDS RELATED TO THE CONSTRUCTION ACTMTIES BEING FABRICATION AND/OR PLACEMENT OF CONSTRUCTION ELEMENTS BUT IT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR TO FIELD 10. SUPPLEMENTAL EQUIPMENT GROUND WIRING LOCATED INDOORS SHALL BE SINGLE COPPER CONDUCTOR(#6 OR LARGER)WITH TYPE THHW.THWN. PERFORMED. ALL RIGGING PLANS SHALL ADHERE TO ANSI/ASSE A10.48(LATEST EDITION)AND CROWN CASTLE USA INC. VERIFY THE DIMENSIONS. MEASUREMENTS,AND/OR CLEARANCES SHOWN IN THE CONSTRUCTION DRAWINGS PRIOR TO FABRICATION OR THWN-2, %HHW,XHHW-2,THW,THW-2,RAW.OR RHW-2 INSULATION UNLESS OTHERWISE SPECIFIED. STANDARD CED-STD-10253,MCLUDING THE REQUIRED INVOLVEMENT OF A QUALIFIES ENGINEER FOR CLASS N CUTTING OF ANY NEW OR EXISTING CONSTRUCTION ELEMENTS. IF IT IS DETERMINED THAT THERE ARE DISCREPANCIES AND/OR CONFLICTS 11. POWER AND CONTROL WIRING IN FLEXIBLE CORD SHALL BE MULTI-CONDUCTOR,TYPE 500W CORD(#14 OR LARGER) UNLESS OTHERWISE SPECIFIED. CONSTRUCTION.TO CERTIFY THE SUPPORTING STRUCTURE(S)IN ACCORDANCE WITH ANSI/MIA-322 (LATEST EDITION). WITH THE CONSTRUCTION DRAWINGS"HE ENGINEER OF RECORD IS TO BE NOTIFIED AS SOON AS POSSIBLE. 12. POWER AND CONTROL WIRING FOR USE IN CABLE-RAY SHALL BE MULTI-CONDUCTOR,TYPE TC CABLE(#I4 OR LARGER), WITH TYPE THHW,THWN, DMO°,5. ALL SITE WORK TO COMPLY WITH OAS-STD-10068'INSTALLATION STANDARDS FOR CONSTRUCTION ACTIVITIES ON CROWN 6. PRIOR TO THE SUBMISSION OF BIDS,THE BIDDING CONTRACTOR SHALL VISIT THE CELL SITE TO FAMILIARIZE WITH THE EXISTING CONDITIONS THWN-2,XHHW,XHHW-2,THW,THW-2,RHW,OR RHW-2 INSULATION UNLESS OTHERWISE SPECIFIED. ,CASTLE USA INC.TOWER SITE"AND LATEST VERSION OF ANSI/MIA-LOIN-A-2012 "STANDARD FOR-NSTALLATION,ALTERATION, AND TO CONFIRM THAT THE WORK CAN BE ACCOMPLISHED AS SHOWN ON THE CONSTRUCTION DRAWINGS.SNY DISCREPANCY FOUND SHALL 13_ ALL POWER AND GROUNDING CONNECTIONS SHALL BE CRIMP-STYLE,COMPRESSION WIRE LUGS AND WIRE NUTS BY THOMAS AND BEETS (OR EQUAL). AND MAINTENANCE OF ANTENNA SUPPORTING STRUCTURES AND ANTENNAS" BE BROUGHT TO THE ATTENTION OF CROWN CASTE. LUGS AND WIRE NUTS SHALL BE RATED FOR OPERATION NOT LESS THAN 75'C (90'C IF AVAILABLE). 6. IF THE SPECIFIED EQUIPMENT CAN NOT BE INSTALLED AS SHOWN ON THESE DRAWINGS, THE CONTRACTOR SHALL PROPOSE 7. ALL MATERIALS FURNISHED AND INSTALLED SHALL BE IN STRICT ACCORDANCE WITH ALL APPUCABLE CODES, REGULATIONS ANC14. RACEWAY AND CABLE TRAY SHALL BE LISTED OR LABELED FOR ELECTRICAL USE IN ACCORDANCE WITH NEMA, UL.AN51/IEEE ANp NEG AL AN ALTERNATIVE INSIALIATION FOR APPROVAL BY CROWN CASTLE USA INC. PRIOR TO PROCEEDING WITH ANY SUCH CHANGE ORDINANCES.CONTRACTOR SHALL ISSUE ALL APPROPRIATE NOTICES AND COMPLY WITH ALL LAWS, ORDINANCES,RULES,REGULATIONS AND 15. ELECTRICAL METALLIC TUBING (EMT),INTERMEDIATE METAL CONDUIT(INTO),OR RIGID METAL CONDUIT(TARO)SHALL BE USED FOR EXPOSED INDOOR R.MARSHALL&ASSOCIATES Al'INSTALLATION. LAWFUL ORDERS OF ANY PUBLIC AUTHORITY REGARDING THE PERFORMANCE OF THE WORK.ALL WORK CARRIED OUT SHALL COMPLY WITH ELECLOCATRNS. ICAL 7 ALL APPLICABLE MUNICIPAL AND UTILITY COMPANY SPECIFICATIONS AND LOCAL JURISDICTIONAL CODES, ORDINANCES AND APPLICABLE 16. ELECTRICAL METALLIC TUBING (EMT) OR METAL-CLAD CABLE MC SHALL BE USED FOR CONCEALED INDOOR LOCATIONS. ALL MATERIALS FURNISHED AND INSTALLED SHALL BE IN STRICT ACCORDANCE WITH ALL APPLICABLE CODES, REGULATIONS REGULATIONS. ( ( ) AND ORDINANCES.CONTRACTOR SHALL ISSUE ALL APPROPRIATE NOTICES AND COMPLY WITH ALL LAWS,ORDINANCES,RULES, 8. UNLESS NOTED OTHERWISE.THE WORK SHALL INCLUDE FLRNISHING MATERIALS, EQUIPMENT,APPURTENANCES AND LABOR NECESSARY TO 17. SCHEDULE 40 PVC UNDERGROUND ON STRAIGHTS AND SCHEDULE 80 PVC FOR ALL ELBOWS/905 AND ALL APPROVED ABOVE GRADE PVC CONDUIT. REGULATIONS AND LAWFUL ORDERS OF ANY PUBLIC AUTHORITY REGARDING THE PERFORMANCE OF THE WORK.ALL WORK COMPLETE ALL INSTALLATIONS AS INDICATED ON THE DRAWINGS. 18. UOUID-TIGHT FLEXIBLE METALL'C CONDUIT (LIQUID-TITE FLEX) SHALL BE USED INDOORS AND OUTDOORS.WHERE VIBRATION OCCURS OR FLEXIBILITY IS CARRIED OUT SHALL COMPLY WITH ALL APPLICABLE MUNICIPAL AND UTILITY COMPANY SPECIFICATIONS AND LOCAL 9. THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS UNLESS NEEDED. JURISDICTIONAL CODES.ORDINANCES AND APPLICABLE REGULATIONS. SPECIFICALLY STATED OTHERWISE. 19. CONDUIT AND TUBING FITTINGS SHALL BE THREADED OR COMPRESSION-TYPE AND APPROVED FOR THE LOCATION USED. SET SCREW FITTINGS ARE NOT 8. THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS 10. IF THE SPECIFIED EQUIPMENT CAN NOT BE INSTALLED AS SHOWN ON THESE DRAWINGS,THE CONTRACTOR SHALL PROPOSE AN ACCEPTABLE. UNLESS SPECIFICALLY STATED OTHERWISE. ALTERNATIVE INSTALLATION FOR APPROVAL BY THE CARRIER AND CROWN CASTLE PRIOR TO PROCEEDING WITH ANY SUCH CHANGE OF 20. CABINETS.BOXES AND WIRE WAYS SHALL BE LABELED FOR ELECTRICAL USE IN ACCORDANCE WITH NEMA,UL ANSI/IEEE ANC THE NEC. 9. THE CONTRACTOR SHALL CONTACT UTILITY LOCATING SERVICES PRIOR TO THE START OF CONSTRUCTION. INSTALLATION. 21. WIREWAYS SHALL BE METAL WITH AN ENAMEL FINISH AND INCLUDE 4 HINGED COVER,DESIGNED TO SWING OPEN DOWNWARDS(WIREMOLD SPECTATE 10. ALL EXISTING ACTIVE SEWER,WATER,GAS, ELECTRIC AND OTHER UTILITIES WHERE ENCOUNTERED IN THE WORK. SHALL BE 11. CONTRACTOR IS TO PEKEORM A SITE INVESTIGATION AND IS TO DETERMINE THE BEST ROUTING OF ALL CONDUITS FOR POWER,AND TELCO WIREWAY). 7 7 PROTECTED AT ALL TIMES AND WHERE REGAINED FOR THE PROPER DICTION OF THE WORK, SHALL BE RELOCATED AS AND FOR GROUNDING CABLES AS SHOWN'N THE POWER,TELCO.AND GROUNDING PLAN DRAWINGS. 22. SLOTTED WIRING DUCT SHALL BE PVC AND INCLUDE COVER(PANDVIT TYPE E OR EQUAL). DIRECTED BY CONTRACTOR. EXTREME CAUTION SHOULD BE USED BY THE CONTRACTOR WHEN EXCAVATING OR DRILLING PIERS 12. THE CONTRACTOR SHALL PROTECT EXISTING IMPROVEMENTS, PAVEMENTS,CURBS, LANDSCAPING AND STRUCTURES.ANY DAMAGED PART 23. CONDUITS SHALL BE FASTENED SECURELY IN PLACE WITH APPROVED NON-PERFORATED STRAPS AND HANGERS. EXPLOSIVE DEVICES(i.e. AROUND OR NEAR JTLITIES.CONTRACTOR SHALL PROS DE SAFETY TRAINING FOR THE WORKING CREW.THIS WILL INCLUDE SHALL BE REPAIRED AT CONTRACTOR'S EXPENSE TO THE SATISFACTION OF CROWN CASTLE USA INC. POWDER-ACTUATED) FOR ATTACHING HANGERS TO STRUCTURE WILL NOT BE PERMITTED. CLOSELY FOLLOW THE LINES OF THE STRUCTURE, MAINTAIN BUT NOT BE LIMITED TO A) FALL PROTECTION B)CONE NED SPACE C) ELECTRICAL SAFETY D) TRENCHING AND EXCAVATION E) 13. CONTRACTOR SHALL LEGALLY AND PROPERLY DISPOSE OF ALL SCRAP MATERIALS SUCH AS COAXIAL CABLES AND OTHER ITEMS REMOVED CLOSE PROXIMITY TO THE STRUCTURE AND KEEP CONDUITS IN TIGHT ENVELOPES. CHANGES IN DIRECTION TO ROUTE AROUND OBSTACLES SHALL BE BU #: 856366 CONSTRUCTION SAFETY PROCEDURES- FROM THE EXISTING FACILITY.ANTENNAS REMOVED SHALL BE RETURNED TO THE OWNER'S DESIGNATED LOCATION. MADE WITH CONDUIT OUTLET BODIES.CONDUIT SHALL BE INSTALLED IN A NEAT AND WORKMANLIKE MANNER. PARALLEL AND PERPENDICULAR TO SCHOLLS &11. ALL SITE WORK SHALL BE AS INDICATED ON THE STAMPED CONSTRUCTION DRAWINGS AND PROJECT SPECIFICATIONS, LATEST 14. CONTRACTOR SHALL LEAVE PREMISES IN CLEAN CONDITION.TRASH AND DEBRIS SHOULD BE REMOVED FROM SITE ON A DAILY BASIS. STRUCTURE WALL AND CEILING LINES.ALL CONDUIT SHALL BE FISHED TO CLEAR OBSTRUCTIONS. ENDS OF CONDUITS SHALL BE TEMPORARILY CAPPED SCHOLLS 125TH APPROVED REVISION. FLUSH TO FINISH GRADE TO PREVENT CONCRETE, PLASTER OR DIRT FROM ENTERING.CONDUITS SHALL BE RIGIDLY CLAMPED TO BOXES BY GALVANIZED 12. CONTRACTOR SHALL KEEP THE SITE FREE FROM ACCUMULATING WASTE MATERIAL,DEBRIS,AND TRASH AT THE COMPLTON MALLEABLE IRON BUSHING ON INSIDE AND GALVANIZED MALLEABLE IRON LOCKNUT ON OUTSIDE AND INSIDE. OF THE WORK. IF NECESSARY, RUBBISH.STUMPS.DEBRIS.STICKS. STONES AND OTHER REFUSE SHALL BE REMOVED FROM 24. EQUIPMENT CABINETS,TERMINAL BOXES,JUNCTION PDXES AND PULL BOXES SHALL BE GALVANIZED OR EPDXY-COATED SHEET STEEL SHALL MEET OR 12655-A SOUTHWEST NORTH THE SFE AND DISPOSED OF LEGALLY. EXCEED UL 50 AND BE RATED NEMA 1 (OR BETTER) FOR INTERIOR LOCATIONS AND NEMA 3R(OR BETTER) FOR EXTERIOR LOCATIONS. DAKOTA STREET 13. ALL EXISTING INACTIVE SEWER,WATER, GAS,ELECTRIC AND OTTER UTILITIES,WHICH INTERFERE WITH THE EXECUTION OF THE 25. METAL RECEPTACLE.SWITCH AND DEVICE BOXES SHALL HE GALVANIZED, EPDXY-COATED OR NON-CORRODING;SHALL MEET OR EXCEED UL 514A AND WORK,SHALL BE REMOVED AND/OR CAPPED, PLUGGED OR OTHERWISE DISCONTINUED AT POINTS WHICH WILL NOT INTERFERE \ NEMA OS 1 AND BE RATED NEMA 1 (OR BETTER) FOP INTERIOR LOCATIONS AND WEATHER PROTECTED(WP OR BETTER) FOR EXTERIOR 'LOCATIONS. TIGARD, OR 97223 WITH THE EXECUTION OF THE WORK, SUBJECT TO THE APPROVAL OF CONTRACTOR,TOWER OWNER,CROWN CASTLE USA INC., /J 26. NONMETALLIC RECEPTACLE, SWITCH AND DEVICE BOXES SHALL MEET OR EXCEED NEMA 05 2 (NEWEST REVISION) AND BE RATED NEMA 1 (OR BETTER) AND/OR LOCAL UTILITIES. FOR INTERIOR LOCATIONS AND WEATHER PROTECTED(WP OR BETTER) FOR EXTERIOR LOCATIONS. IA. THE CONTRACTOR SHALL PROVIDE SITE SIGNAGE IN ACCORDANCE WITH THE TECHNICAL SPECIFICATION FOR SITE SIGNAGE CONCRETE. FOUNDATIONS, AND REINFORCING STEEL: 27. THE CONTRACTOR SHALL NOTIFY AND OBTAIN NECESSARY AUTHORIZATION FROM THE CARRIER AND/OR CROWN CASTLE USA INC. BEFORE COMMENCING REQUIRED BY LOCAL JURISDICTION AND SIGNAGE REQUIRED CN INDIVIDUAL PIECES OF FOIRPMENT, ROOMS,ANO SHELTERS. WORK ON THE AC POWER DISTRIBUTION PANELS. 15. THE SITE SHALL BE GRADED TO CAUSE SURFACE WATER TO FLOW AWAY FROM THE CARRIER'S EQUIPMENT AND TOWER 28. THE CONTRACTOR SHALL PROVIDE NECESSARY TAGGING ON THE BREAKERS,CABLES AND DISTRIBUTION PANELS IN ACCORDANCE WITH THE APPLICABLE AREAS. CODES AND STANDARDS TO SAFEGUARD LIFE AND PROPERTY. 16. THE SUB GRADE SHALL BE COMPACTED AND BROUGHT'D A SMOOTH UNIFORM GRADE PRIOR TO FINISHED SURFACE 1. ALL CONCRETE WORK SHALL BE IN ACCORDANCE WET THE ACI 301,ACI 318,ACI 336,ASHA A184.ASTM A185 AND THE DESIGN AND 29. INSTALL LAMICOID LABEL ON THE METER CENTER TO SHOW"AT&T" APPLICATION. CONSTRUCTION sPEC:SCAnoN FOR CAST-IN-PLACE CONCRETE. REV DATE DESCRIPTION 17. IHL ANUS U- THE OWNERS DISTURBED BY THE WORK AND COVERED BY THE TOWER,EQUIPMENT OR 2. UNLESS NOTED OTHERWISE,SOIL BEARING PRESSURE USED FOR DESIGN OF SLABS AND FOUNDATIONS IS ASSUMED TO RE 1000 psf. 30- ALL EMPTY/SPARE CONDUITS THAT ARE INSTALLED ARE TO HAVE A METERED MULE TAPE FULL CORD INSTALLED. DRIVEWAY, SHAH BE GRADED PROPERTY A UNIFORM DRM SLOPE.AND STABILIZEDKTO NOT PREVENT EROSION AS SPECIFIED ED EQUIPMENT O THE 3. ALL CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH(1'c)OF 3000 psi AT 28 DAYS, UNLESS NOTED OTHERWSE NO MORE A 1/21/22 PRELIMS THAN 90 MINUTES SHALL ELAPSE FROM BATCH TIME-0 TIME OF PLACEMENT UNLESS APPROVED BY THE ENGINEER OF RECORD_ CONSTRUCTION DRAWINGS AND/OH PROJECT SPECIFICATIONS. TEMPERATURE OF CONCRETE SHALL NOT EXCEED 90'f AT TIME OF PLACEMENT. 0 3/24/22 FOR CONSTRUCTION 18. CONTRACTOR SHALL MINIMIZE DISTURBANCE TO EXISTING SITE DURING CONSTRUCTION. EROSION CONTROL MEASURES.IF 4. CONCRETE EXPOSED TO FREEZE-THAW CYCLES SHALL CONTAIN AIR ENTRAINING ADMIXTURES-AMOUNT OF AIR ENTRAINMENT TO BE BASED REQUIRED DURING CONSTRUCTION,SHALL BE IN CONFORMANCE WITH THE LOCAL GUIDELINES FOR EROSION AND SEDIMENT ON SIZE OF AGGREGATE AND F3 CLASS EXPOSURE(VERY SEVERE). CEMENT USED TO BE TYPE II PORTLAND CEMENT WITH A MAXIMUM • CONTROL. WATER-TO-CEMENT RATIO(W/C)OF 0.45, 19. THE CONTRACTOR SHALL PROTECT EXISTING IMPROVEMENTS,PAVEMENTS,CURBS, LANDSCAPING AND STRUCTURES.ANY 5. AL'_STEEL REINFORCING SHALL CONFORM TO ASTM AA15.ALL WELDED WIRE FABRIC(YAW)SHALL CONFORM TO ASTM A185.ALL SPLICES DAMAGED PART SHALL BE REPAIRED AT CONTRACTOR'S EXPENSE TO THE SATISFACTION OF OWNER. SHALL BE CLASS "B"TENSION SPLICES,UNLESS NOTED OTHERWISE. ALL HOOKS SHALL BE STANDARD 90 DEGREE HOOKS, UNLESS NOTED 20. 'CONTRACTOR SHALL LEGALLY AND PROPERLY DISPOSE OF ALL SCRAP MATERIALS SUCH AS COAXIAL CABLES AND OTHER OTHERWISE.YIELD STRENGTH (Fy) OF STANDARD DEFORMED BARS ARE AS FOLLOWS: ITEMS REMOVED FROM THE EXISTING FACILITY.ANTENNAS REMOVED SHALL BE RETURNED TO THE OWNER'S DESIGNATED #4 BARS AND SMALLER 40 ksi CONDUCTOR COLOR CODE LOCATION. #5 BARS AND LARGER 60 Psi 21. CONTRACTOR SHALL LEAVE PREMISES IN CLEAN CONDITION. TRASH AND DEERS SHOULD BE REMOVED FROM SITE ON A DAILY 6. THE FOLLOWING MINIMUM CONCRETE COVER SHALL BE PROVIDED FOR REINFORCING STEEL UNLESS SHOWN OTHERWISE ON DRAWINGS: SYSTEM CONDUCTOR COUCH BASIS. CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH 3" A PHASE BLACK 22. NO FILL OR EMBANKMENT MATERIAL SHALL BE PACED ON FROZEN GROUND. FROZEN MATERIALS,SNOW OR ICE SHALL NOT CONCRETE EXPOSED TO EARTH OR WEATHER BE PLACED IN ANY FILL OR EMBANKMENT. B PHASE REDi APWA UN FORM COLOR CODE: i6 BARS AND LARGER 2' 120/240V, 10 - - -- 45 BAPS AND SMALLER 1-1/2' NEUTRAL WHITE CONCRETE NOT EXPOSED TO EARTH OR WEATHER: GROUND GREEN ' SLAB AND WAILS 3/4 A PHASE BLACK WHITE PROPOSED EXCAVATION BEAMS AND COLUMNS '-I/O" 7. A TOOLED EDGE OR A 3/4'CHAMFER SHALL BE PROVIDED AT ALL EXPOSED EDGES OF CONCRETE, UNLESS NOTED OTHERWISE, IN B PHASE RED Pllir. TEMPORARY SURVEY MARKINGS ACCORDANCE WITH ACI 301 SECTION 4,2.4, 120/208V, 30 1 C PHASE BLUE ---- ELECTRIC POWER LINES,CABLES, CONDUIT, I NEUTRAL WHITE ''EC AND LIGHTING CABLES I GROUND GREEN GAS,OIL, STEAM. PETROLEUM,OR GASEOUS A PHASE BROWN MATERIALS ' ..A. B PHASE ORANGE OR PURPLE URANLE COMMUNICATION,ALARM OR SIGNAL UNES,CABLES, 277/400V,30 C PHASE YELLOW OR CONDUIT AND TRAFFIC LOOPS - >_REENEIELD GROUNDING NOTES: NEUTRAL GREY ®POTABLE WATER GROUND GREEN 1. ALL GROUND ELECTRODE SYSTEMS(INCLUDING TELECOMMUNICATION, RADIO, LIGHTNING PROTECTION AND AC POWER GES'S)SHALL 3E BONDED TOGETHER AT OR BELOW GRADE, BY TWO OR MORE COPPER BONDING CONDUCTORS IN ACCORDANCE WITH THE NEC. POST(HA RED"' ""RP" LINES IMED WATER, IRRIGATION,AND SLURRY 2. THE CONTRACTOR SHALL PERFORM IEEE FALL-OF-POTENTAL RESISTANCE TO EARTH TESTING(PER IEEE 1100 AND HI) FOR GROUND ELECTRODE SYSTEMS.THE CONTRACTOR SHALL FURNISH AND INSTALL SUPPLEMENTAL GROUND ELECTRODES AS NEEDED TO ACHIEVE A TEST DC VOLTAGE NEG(-) BUCK" RESULT OF 5 OHMS OR LESS. YETEI SEWERS AND DRAIN LINES DESIGNED:JLB 3. THE CONTRACTOR IS RESPONSIBLE FOR PROPERLY SEQUENCING GROUNDING AND UNDERGROUND CONDUIT INSTALLATION AS TO PREVENT ANY LOSS OF CONTINUITY IN THE GROUNDING SYSTEM OR DAMAGE TO THE CONDUIT AND PROVIDE TESTING RESULTS. 'SEE NEC 210.5(0)(I)AND (2) E 4. METAL CONDUIT AND TRAY SHALL BE GROUNDED AND MADE ELECTRICALLY CONTINUOUS WITH LISTED BONDING FITTINGS OR BY BONDING ACROSS THE DSCONTINUITY WITH#6 COPPER WIRE UL APPROVED GROUNDING TYPE CONDUIT CLAMPS. "POLARITY MARKED AT TERMINATION DRAWN: JLB 5. METAL RACEWAY SHALL NOT BE USED AS THE NEC REQUIRED EQUIPMENT GROUND CONDUCTOR. STRANDED COPPER CONDUCTORS WITH GREEN INSULATION,SIZED IN ACCORDANCE WITH THE NEC,SHALL BE FURNISHED AND INSTALLED WITH THE POWER CIRCUITS TO BTS EQUIPMENT. ABBREVIATIONS: CHECKED: PWM 6. EACH CABINET'FRAME SHALL BE DIRECTLY CONNECTED TO THE MASTER GROUND BAR WITH GREEN INSULATED SUPPLEMENTAL EQUIPMENT GROUND WIRES,#6 STRANDED COPPER OR LARGER FOR INDOOR EFTS; #2 BARE SOLID TINNED COPPER FOR OUTDOOR BTS. 7 CONNECTIONS TO THE GROUND BUS SHALL NOT BE DOUBLED LIP OR STACXED BACK TO BACK CONNECTIONS ON OPPOSITE SIDE OF THE GROUND BUS ARE PERMITTED. 8. ALL EXTERIOR GROUND CONDUCTORS BETWEEN EQUIPMENT/GROUND BARS AND THE GROUND RING SHALL BE#2 SOLID TINNED COPPER JNLESS OTHERWISE INDICATED. ANT ANTENNA .I 9. ALJMINUM CONDUCTOR OR COPPER CLAD STEEL CONDUCTOR SHAII NOT BE USED FOR GROUNDING CONNECTONS_ (E) EXISTING JOB p: '0. USE OF 90' BENDS IN TIE PROTECTION GROUNDING CONDUCTORS SHALL BE AVOIDED WHEN 45'BENDS CAN BE ADEQUATEIT SUPPORTED. FIF FACILITY INTERFACE FRAME amncsc 21CCAO6M-0I41 T. EXOTHERMIC WELDS SHALL BE USED FOR ALL GROUNDING CONNECTIONS BELOW GRADE. GEN GENERATOR EXPIRES:6/30/2022 2. ALL GROUND CONNEC-IONS ABOVE GRADE (INTERIOR AND EXTERIOR) SHALL BE FORMED USING HIGH PRESS CRIMPS. CPS GLOBAL POSITIONING SYSTEM • 3. COMPRESSION GROUND CONNECTIONS MA'BE REPLACED BY EXOTHERMIC WELD CONNECTIONS. GSM GLOBAL SYSTEM FOR MOBILE 4. ICE BRIDGE BONDING CONDUCTORS SHALL BE EXOTHERMICALLY BONDED OR BOLTED TO THE BRIDGE AND THE TOWER GROUND BAR. LTE LONG TERM EVOLUTION 5. APPROVED ANTIOXIDANT COATINGS(I.r. CONDUCTIVE GEL OR PASTE)SHALL BE USED ON ALL COMPRESSION ANC BOLTED GROUND CONNECTIONS. MOB MASTER GROUND BAR 6. ALL EXTERIOR GROUND CONNECTIONS SHALL BE COATED WITH A CORROSION RESISTANT MATERIAL. MW MICROWAVE 7. MISCELLANEOUS ELECTRICAL AND NON-ELECTR'LAL MEAL BOXES, FRAMES AND SUPPORTS SHALL BE BONDED TO THE GROUND RING, IN ACCORDANCE WITH THE NEC. (N) NEW 8. BOND ALL METALLIC OBJECTS WITHIN 6 H OF MAIN GROUND RING WITH(1) M2 BARE SOLID TINNED COPPER GROUND CONDUCTOR. NEC NATIONAL ELECTRIC CODE 9. GROUND CONDUCTORS USED FOR THE FACILITY GROUNDING AND LIGHTNING PROTECTION SYSTEMS SHALL NOT BE ROUTED THROUGH METALLIC OBJECTS THAT FORM A RING AROUND THE CONDUCTOR,SUCH AS METALLIC CONDUITS, METAL SUPPORT CLIPS OR SLEEVES THROUGH (P) PROPOSED GENERAL NOTES WALLS OR FLOORS. WHEN IT IS REQUIRED TO BE HOUSED IN CONDUIT TO MEET CODE REQUIREMENTS OR LOCAL CONDITIONS, NON-METALLIC MATERIAL SUCH AS PVC CONDUIT SHALL BE USED.WHERE USE OF METAL CONDUIT IS UNAVOIDABLE(i.e.. NONMETALLIC CONDUIT PP POWER PLANT PROHIBITED BY LOCAL CODE)THE GROUND CONDUCTOR SHALL BE BONDED TO EACH END OF THE METAL CONDUIT. STY QUANTITY 20. ALL GROUNDS THAT TRANSITION FROM BELOW GRADE TO ABOVE GRADE MUST BE#2 BARE SOLID TINNED COPPER IN 3/4"NON-METALLIC,FLEXIBLE CONDUIT FROM 24'BELOW GRADE TO WITHIN 3"TO 6"OF CAD-WELD TERMINATION POINT.THE EXPOSED END OF THE REST RECTIFIER ADO TRANSITIONING GROUND STANDARD DETAIL AS REIS RADIO BASE STATION CONDUIT MUST BE SEALED WITH SILICONE CAULK. ( WELL). RET REMOTE ELECTRIC TILT 21. BUILDINGS WHERE THE MAIN GROUNDING CONDUCTORS ARE REQUIRED TO BE ROUTED TO GRADE,THE CONTRACTOR SHALL ROUTE TWO GROUNDING CONDUCTORS FROM THE ROOFTOP,TOWERS,AND WATER TOWERS GROUNDING RING. TO THE EXISTING GROUNDING SYSTEM,THE REDS RADIO FREQUENCY DATA SHEET GROUNDING CONDUCTORS SHALL NOT BE SMALLER THAN 2/0 COPPER. ROOFTOP GROUNDING RING SHALL BE BONDED TO THE EXISTING GROUNDING SYSTEM,THE BUILDING STEEL COLUMNS, LIGHTNING PROTECTION SYSTEM,AND BUILDING MAIN WATER LINE(FERROUS OR RRH REMOTE RADIO HEAD NONFERROUS METAL PIPING ONLY). BRA REMOTE RADIO UNIT SIAD SMART INTEGRATED DEVICE TMA TOWER MOUNTED AMPLIFIER T-2 TYYP TYPICAL OATS UNIVERSAL MOBILE TELECOMMUNICATIONS SYSTEM W.P. WORK POINT AT&T -44 4 CROWN 111 CASTLE 1505 W ESTLAKE AVENUE NORTH,SUITE 800 SE_ATTLE,WA 98109 pfro°4414 P.MARSHALL&ASSOCIATES APPROXIMATE LOCATION OF PROPERTY LINE I I I . ' 77 Q 0 I I BU #: 856366 o I 1 SCHOLLS Sc 125TH 12655—A SOUTHWEST NORTH DAKOTA STREET Z I �� TIGARD, OR 97223 H SUBJECT PARCEL: /� // a R2032709 7" / ZONING: ��/L //// Iz C-P /% to ce REV 11 DATE DESCRIPTION IJ ✓� to A 1/21/22 PRELIMS o j 0 0 3/24/22 FOR CONSTRUCTION 116 Io / ! . L/ /77/..."////T: ////////7/;y / IO to _ V / f 6 EXISTING ACCESS ROAD x V o v. f I., ce o a j EXISTING a . B.� l BUILDING / . STING SITE LOCATION / / .Yi ' -SEE SHEET C-1.2 FOR DETAILS ■ f/„/////////f/f/Z=Z / ////7 7// , o - - - - APPROXIMATE LOCATION OF PROPERTY LINEwar' _ trr __.. DESIGNED:JLB DRAWN: JLB CHECKED: PWM Ii*V�Lp�`( JOB #. =.rzaacu 21 CCAO6M-0141 NEXPIRES 6/30/2022 I W - PMeAi— E OVERALL SITE PLAN ` ! -. SITE PLAN UIOCWMER: PROPERTY LINES AND STRUCTURES HAVE BEEN OVERALL SITE PLAN DIGITIZED FROM JURISDICTIONAL GIS.CROWN CASTLE USA INC.HAS NOT COMPLETED A SITE S 1 4rfA 1 1.=20'-0" (FULL SIZE SURVEY MID THEREFORE MANES NO CLAIMS AS 20' 10 0 2D 1"=4D-O (11x17) TO THE U ACY OF INFORMATION DEPICTED ON THISC C-1 .1 EXISTING AT&T 11'-7" X AT&T 19'-6" EQUIPMENT PAD EXISTING AT&T III PANEL & �A) POWER METER ' TELCO CABINET . EXISTT G \\ P,t°"'»T' CROWN • CABINET , CASTLE \ Jg V / \ 1_ 1505 WESTLAKE AVENUE NORTH,SUITE 8G0 5 y SEP.TFLE.WA 98109 i EXISTING MINI-PURCELL FLX21 ' ��II W/ NOKIA FSM4 FSM4(AMIA) • pim.,,,..AA, %�, EXISTING AT&T FEEDLINESEXISTING MONOPOLE - (6) 7/B COAX CABLES --�,OI EXISTING EXISTING 41:\'�; - (5) #8 Awc UN TRUNKS P.MARSHALL&ASSOCIATES "//1J ARGUS TE40 ARGUS T 44 '� - (2) FIBER TRUNK BATTERY BATTER (1) RET CABINET TO CABINET EXISTING AT&T ICE II BE REMOVED BE REM# E ARXISTING--1 I - BRIDGE (+/-20'-0") CABINET W/ �.'� .'� RAYCAP DC6 '. PP77 (RETIRED), '/I< Mill , CONVERTER I _ -• • `--- '- ' SYSTEM & SIAD '�_ BU #: 856366 EXISTING RAYCAP EXISTING RAYCAP EXISTING +24V DC POWER PLANT TO BE REMOVED SCHOLLS Sc 125TH REMOVE POWER EQUIPMENT FROM EXISTING DC12 (LTE) DC12 (LTE) - BATTERIES TO REMAIN 12655—A SOUTHWEST NORTH CONVERTER SHELF, REMOVE CONVERTER SHELF; DAKOTA STREET TRANSFER LOADS TO NEW POWER PLANT TIGARD, OR 97223 NOIE: EXISTING EQUIPMENT PLAN EQUIPMENT LAYOUT SHOWN IS BASED ON THE PREVIOUS ee - �, 1"-2.-0” (FULL SIZE) N/ CONSTRUCTION DRAWINGS DONE BY CROWN CASTLE 2 1 0 2' 1"=4'-0" (11x17) 7 '"( REV DATE DESCRIPTION DATED 5/18/20 AS WELL AS MOST RECENT AUDIT PHOTOS MID MEASUREMENTS.IF EQUIPMENT LAYOUT Cl/ DIFFERS FROM WHAT IS SHOWN.CONTRACTOR TO MFyA �y A 1/21/22 PRELIMS CONTACT THE CONSTRUCTION MANAGER. 0 3/24/22 FOR CONSTRUCTION rn EXISTING AT&T 11'-7' X 19'-6" EQUIPMENT PAD EXISTING AT&T AC PANEL & POWER METER C— TELCO CABINET O EXISTING ��F. UMTS 5 EXISTING FSM4 (AMIA) - UTILIZE EXISTING (1) ASIA AND (3) ABIA I CABINET CARDS ON THE Cl SIDE FOR LTE. REMOVE EXISTING (1) ASIK AND (1) T\ j X , ABIL CARDS ON THE C2 SIDE. ADD (1) ASIL AND (3) ABIO CARDS TO \ / I JB I THE C2 SIDE FOR 5G 850/1900/AWS, 5G C n77 & 5G C n77 dod \ \ // { / EXISTING MINI-PURCELL FLX21 W/ NOKIA FSM4 FSM4(AMIA) I \� �`� PROPOSED AT&T (2) 6 AWG DC TRUNK(S) EXISTING MONOPOLE \' �X, k EXISTING AT&T FEEDLINES � � �\ - (6) 7/8" COAX CABLES 111 - (5) #8 AWG DC TRUNKS DESIGNED:JLB ��'=='� - (2) FIBER TRUNK mil - DRAWN: JLB �. - (1) RET _ EXISTING / /k� / -,f ` '' V- EXISTING AT&T ICE IR CHECKED PWM ARGUS TE43 �' \V ' / / BRIDGE (+/-20'-0") \:" __,,/2 JOB CABINET W/ ---- ,ice,x,,, 21CCA06M-0141 RAYCAP DC6 / � _ .. � � / y ' V \.� ,/,, z _0 EXPIRES-6/30/2022 (RETIRED) & �- ( - SIAD 4, EXISTING RAYCAP — EXISTING RAYCAP PROPOSED -48V EMERSON NETSURF 512 DC PLANT DC12 (LTE) DC12 (LTE) W/ (11) RECTIFIERS & (2) CONVERTER MODULES EXISTING Sc FINAL PROPOSED EMERSON BATTERY CABINET EQUIPMENT PLANS THIS PAGE CONTAINS CONFIDENTIAL.PROPRIETARY OR TRADE SECRET INFORMATION INSTM IFR NOTE. EXEMPT FROM DISCLOSURE UNDER APPLICABLE LAW. BATTERY NOTE: CROWN CASTLE HAS BEEN INFORMED BY THE CARRIER THAT THE REMOVAL OF THE FINAL EQUIPMENT PLAN RECONFIGURE (16) +24V STRINGS CAND SETEEXNEW CE �IEUANDTTaIA EQUIPMENT UGRADETOTHEE EXISTING AC ELECTRICAL S THAT THE seesaw reeked by A m tar e reeemene tlaes as rensemee engmnp ernyusav des*, I earc 1”--2.-0"" (FULL SIZE) AS (8) —48V STRINGS AT FINAL. IN c PROPOSED EQUIPMENT WILL UTILIZE THE SAME BREN(ER,WIRE.MID CONDUIT THAT viifr�g 2' 1' 0 2' 1"=4'—O" 11 x17 WAS USED FOR THE EQUIPMENT BONG REPLACED.THE CONTRACTOR IS TO NOTIFY ( ) THE ENGINEER OF RECORD IF ANY ELECTRICAL ARONS TO THE EXISTING AC M 1 2 ELECTRICAL SYSTEM ARE NECESSARY FOR THE REQUESTED WORK TO BE PERFORMED. r NOTES: 1. CONTRACTOR TO VERIFY ALL ANTENNA TIP HEIGHTS DC A1 &i NOT EXCEED BEACON BASE HEIGHT. =10100. . , MOUNT ANALYSIS NOTES: AT&T AEQK ANTENNA CENTERLINE � / 56.75' A.G.L. 1. THE DESIGN DEPICTED IN THESE DRAWINGS IS VALID ..� WHEN ACCOMPANIED BY A CORRESPONDING PASSING = = AT&T LTE ANTENNA CENTERLINE - 1. MOUNT ANALYSIS. - - - - - - 2. CONSTRUCTION MANAGER / GENERAL CONTRACTOR SHALL = 54' A.G.L. CROWN REVIEW THE MOUNT ANALYSIS FOR ANY CONDITIONS PRIOR \ AT&T AEQU ANTENNA CENTERLINE CASTLE TO INSTALLATION. 3. ANY REQUIRED MOUNT MODIFICATION DESIGN OR MOUNT 51.25' A.G-L. agALN REPLACEMENT SHALL BE APPROVED BY EOR. I AT&T EQUIPMENT TO BE INSTALLED 1505 WESTLAKE AVENUE NORTH,SUITE BCC 1 EXISTING AT&T EQUIPMENT TO REMAIN - (3) COMMSCOPE NNH4-65C-R6-HG ANTENNAS SEATTLE WA 98109 '.. - 3 NOKIA AE K ANTENNAS 1 O q.I - (3) ANTENNAS - (15) RRH - (3) NOKIA AEgU ANTENNAS - (2) DC6-48-60-18-8F RAYCAP SQUID PROPOSED SITE PRO 1 6CHMT COLLAR MOUNT pm,0,,,4 - (1) DC9-48-60-24-8C-EV RAYCAP SQUID FOR RRH MOUNTED BELOW AT&T MOUNT EXISTING AT&T EQUIPMENT TO BE REMOVED EXISTING AT&T EQUIPMENT TO REMAIN - (3) ANTENNAS - (3) CELLMAX CMA-UBTULBULBHH-6517 17 21-21 ANTENNAS - (3) KMW EPBQ-652L8H8 ANTENNAS - (15) RRH P.MARSHALL&ASSOCIATES - (2) DC6-48-60-18-8F RAYCAP SQUID - (1) DC9-48-60-24-8C-EV RAYCAP SQUID THIS PAGE CONTAINS CONFIDENTIAL.PROPRIETARY OR TRADE SECRET INFORMATION EXEMPT FROM DISCLOSURE UNDER APPLICABLE LAW. 17 7 Pm14.r VTW`dd erA1,,11r;rtetnne.,t hn net(WJt*tuh na+.emp exbHu whiff^ BU #: 856366 0 SCHOLLS & 125TH J Q J EXISTING AT&T FEEDLINES a - EXISTING AT&T FEEDLINES 12655-A SOUTHWEST NORTH o� II - (6) 7/8" COAX CABLES II - (6) 7/8" COAX CABLES DAKOTA STREET i' x - (5) #8 AWG DC TRUNKS to - (5) #8 AWG DC TRUNKS TIGARD, OR 97223 IJ - (2) FIBER TRUNK w - (2) FIBER TRUNK 3 z - (1) RET = 3 " . - (1) RET a i z < z PROPOSED AT&T (2) z #6 AWG DC TRUNK(S) ,F I- 1- - REV, DATE DESCRIPTION Q z JJ A 1/21/22 PRELIMS IA a Or-' a o a Z a 0 3/24/22 FOR CONSTRUCTION o 0 0 z I rn Sc w EXISTING MONOPOLE TOWER EXISTING MONOPOLE TOWER --i - - DESIGNED'.JIB aaR. - Ma a1j aM. aaa I ap --as i + CHECKED: PWM as, JOR 1 I . 21CCAO6M-0141 EXPIRES:6/30/2022 EXISTING & FINAL ELEVATIONS EXISTING EAST ELEVATION FINAL EAST ELEVATION NOT TO SCALE NOT TO SCALE C-2 EXISTING AT&T RRH TO REMAIN NOKIA 4T4R B12/14 AHLBA �AE.� AT&T (TOTAL OF 3, 1 PER SECTOR) /�60 EXISTING AT&T RAYCAP Al DC6-48-60-18-8F TO REMAIN %��^'1'" (TOTAL OF 2. ALPHA & BETA SECTORS) *}�J EXISTING PLATFORM MOUNT TO REMAIN ' EXISTING AT&T ANTENNAS TO REMAINCELLMAX CROWN (TOTAL OF 3, 1UPER SECTOR)LBHH 6517-17-21-21 9 444000 CASTLE - RELOCATE TO POSITION 4 AT ALPHA & BETA SECTORS ' ` y ,s@1 � - RELOCATE TO POSITION 1 AT GAMMA SECTOR 505 WESTLAKE AVENUE NORTH.SUITE BCC '60 SEAT'LE.WA 98109 EXISTING AT&T ANTENNAS TO BE REMOVED - 'I"'� 3/ KMW EPBQ-652L8H8 �;, } Y EXISTING AT&T RRH TO REMAIN (TOTAL OF 3, 1 PER SECTOR) L� G4� e A NOKIA 4T4R 85 AHCA ''''',y i t 4.„ .Q2‘;',1 y;Y-,...-: ..'''. C,>'' Ajk lik (TOTAL OF 3, 1 PER SECTOR) LD) 0 „,,v;...:,„P1 —---: ::: :-.III,"'-,,..',..' AV L EXISTING AT&T RRH TO REMAIN e� c3 �� + , � � P.MARSHALL&ASSOCIATES NOKIA RRH4X25-WCS-4R -- ' k\ > (TOTAL OF 3, 1 PER SECTOR) �'rLNN \ .�, - I EXISTING AT&T ANTENNAS TO BE REMOVED - RE-PLUMB TO POSITION 1 AT ALPHA & BETA SECTORS 1 CELLMAX CMA-UBTULBULBHH-6517-17-21-21 B1 (TOTAL OF 3, 1 PER SECTOR) EXISTING AT&T RRH TO REMAIN -%<� NOKIA B66A RRH4X45-4R `ro (TOTAL OF 3, 1 PER SECTOR) x I P 7 7 EXISTING AT&T RAYCAP d B3 EXISTING AT&T RRH - REMAIN CBUH #: 856366 DC9-48-60-24-8C-EV TO REMAIN .F,�GI • \IPP < NOKIA 625 RRH4X30-4R SCHOLLS & 125TH (TOTAL OF 1, GAMMA SECTOR) �'N� 4 �J`x s (TOTAL OF 3, 1 PER SECTOR) d ti \� �•�� 12655-A SOUTHWEST NORTH DAKOTA STREET sa;<� NOTES TIGARD, OR 97223 N 1. CONTRACTOR TO VERIFY ALL ANTENNA TIP HEIGHTS DO NOTE. EXISTING ANTENNA PLAN NOT EXCEED BEACON BASE HEIGHT. THIS PAGE CONTAINS CONFIDENTIAL PROPRIEFARY OR TRADE SECRET INFORMATION (11DI viiitu I 1"=3'-D" (FULL SIZE) v EQUIPMENT LAYOUT SHOWN IS RASED ON THE PRE4TOU5 EXEMPT FROM DISCLOSURE UNDER APPLICABLE LAW. MOUNT ANAL SS NOTES: CONSTRUCTION DRAWINGS DONE BY CROWN CASTLE 3' 1.5' 0 3' 1"=6'-0" (11x17) REV DATE DESCRIPTION _ DATED 5/18/20 AS WELL AS MOST RECENT AUDIT 1. THE DESIGN DEPICTED IN THESE DRAWINGS IS VALID PHOTOS AND MEASUREMENTS.IF EQUIPMENT LAYOUT A 1/21/22 PRELIMS DIFFERS FROM WHAT IS SHOWN,CONTRACTOR TO WHEN ACCOMPANIED BY A CORRESPONDING PASSING CONTACT THE CONSTRUCTOR MANAGER. 0rxratmer xdrd or Ars r Ms stotenrn don rorraadruh r.p.wena aaMn a dna. MOUNT ANALYSIS. 0 3/24/22 FOR CONSTRUCTION �S� 2. CONSTRUCTION MANAGER / GENERAL CONTRACTOR SHALL EXISTING AT&T RAYCAP \SE"'` REVIEW THE MOUNF ANALYSIS FOR ANY CONDITIONS PRIOR DC6-48-60-18-8F TO REMAIN 1Al 6� PROPOSED AT&T ANTENNAS TO INSTALLATION. (TOTAL OF 2, ALPHA & BETA SECTORS) COMMSCOPE NNH4-65C-R6-HG 3. ANY REQUIRED MOUNT MODIFICATION DESIGN OR MOUNT (TOTAL OF 3, 1 PER SECTOR) REPLACEMENT SHALL BE APPROVED BY EOR. _ EXISTING AT&T RRH TO REMAIN NOKIA 4T4R 612/14 AHLBA r ` (TOTAL OF 3, 1 PER SECTOR) '' gG/� PROPOSED 2nd FIBER JUMPER /-.60 CONNECTION FOR EXISTING B66 RRH / ' �1 A3 PROPOSED SITE PRO 1 6CHMT COLLAR MOUNT (TOTAL OF 3, 1 PER SECTOR) r, . _ ` FOR RRH MOUNTED BELOW AT&T MOUNT I EXISTING AT&T RRH TO REMAIN , "�' NOKIA 666A RRH4X45-4R '/ �� �, (TOTAL OF 3, 1 PER SECTOR) - ` ,, �'(6�,f ' - -N 1N, ''I'' c''`' ,V'�Nd ,' _I '- I a - EXISTING AT&T ANTENNAS TO REMAIN n. CELLMAX CMA-UBTULBULBHH-6517-17-21-21 - .I. rill (TOTAL OF 3, 1 PER SECTOR) RELOCATED TO POSITION 4 AT ALPHA & BETA SECTORS EXISTING AT&T RRH TO REMAIN - -- I I - RELOCATED TO POSITION 1 AT GAMMA SECTOR NOKIA RRH4X25-WCS-4R `` mil' '� +I (TOTAL OF 3, 1 PER SECTOR) G3 EXISTING AT&T RRH TO REMAIN - DESIGNED:JLB - RE-PLUMBED TO POSITION 1 AT ALPHA & BETA SECTORS SCNO "p NOKIA 4T4R 05 AHCA DRAWN: JLB �/4-`L �, ffTl (TOTAL OF 3, 1 PER SECTOR) PROPOSED AT&T ANTENNAS A - . ' / CHECKED: PWM NOKIA AEQK �' 1 \;F - (TOTAL OF 3, 1 PER SECTOR) ®� ,p s - MATCH EXISTING TIP HEIGHTS G1 T / i B3 o. ,, JOB PROPOSED AT&T ANTENNAS �� • "�Y•+��I�,,= 21 CCA06M-0141 NSF,\› , .,, \ EXPIRES:6/30/2022 NOKIA AEQU f .LNG --' No PROPOSED 2nd FIBER JUMPER (TOTAL OF 3, 1 PER SECTOR) g4 �O.\ CONNECTION FOR EXISTING B25 RRH - - MOUNT BELOW AEOK - 36" VERTICAL SEPARATION FROM AEOK \<.. (TOTAL OF 3, 1 PER SECTOR) 'F EXISTING AT&T RRH TO REMAIN EXISTING & FINAL EXISTING AT&T RAYCAP 'J�sc NOKIA B25 RRH4X30-4R DC9-48-60-24-8C-EV TO REMAIN (TOTAL OF 3, 1 PER SECTOR) ANTENNA PLANS • (TOTAL OF 1, GAMMA SECTOR) EXISTING PLATFORM MOUNT TO REMAIN N ITFINAL ANTENNA PLAN krrr„.(r'”,1„„ „,x„j 1"=3'-0" (FULL SIZE) C-3 3' 1.5' 0 3' 1"=6'-0" (11)(17) AT&T FINAL EQUIPMENT SCHEDULE (VERIFY WITH CURRENT RFDS) ALPHA ANTENNA RADIO DPLD(ERR TWA SURGE PROTECTION CABLES '• CROWN POSmoo TECH. STATUS/MANUFACNREA MODEL A21WTH RAD CENTER QTY. STATUS/YODEL LOCATION QTY. STATUS LDCAND8 QTY. STATUS/YODEL QTY. STATUS/MODEL 01Y. STATUS/TYPE LENGTH I (E) 4T4R 812/14 AHLB4 TOWER CASTLE I Al LTE/5G (P)COMMSCOPE 60' 54' I (E)B25 RRH4X30-4R TOWER - - - - - 2 (E)7/8'COAX 1505 WESTLAKE AVENUE NORTH,SUITE 80C NNH4-65C-R6-HG • 1 (P)RRH4X25-WCS-4R TOWER 1 (E)RET 90'-a' SEATTLE,WA 98109 2 (E) #8 AWG DC 90'-0' A2 - - - - - - - - - - - - 1 (E) DC6-48-60-18-8F 1 (E) FIBER 90'-0' D J A3 5G (P) NOKIA AEOK+AEOU STACKED 60' 51.257 - - - - - - - - - - - _ - 1 11V11.6 A 56.75' P.MARSHALL&ASSOCIATES 1 (E)4T4R 135 AHCA TOWER A4 LTE (E) CELLMAX 60' 54' - - - - - - - - - - CMA-UBRILBULBHH-6517-17-21-21 1 (E)BMA RR1-14X45-4R TOWER BETA 1 (E)4T4R B12/14 AHLBA TOWER D 7 7 B1 LTE/5G (P)COMMSCOPE 150' 54' 1 (E) B25 RRH4X30-4R TOWER - - - - - - - 2 (E)7/8•COW 90'-0° NNH4-65C-R6-HG 1 (P)RRH4X25-WCS-4R TOWER RU #: 856366 2 (E) #8 AWG DC 90•-0• SCROLLS & 125TH B2 - - - - - _ - - - _ - - 1 (E)006-46-60-18-BF 1 (E)FIBER 90-0" 12655-A SOUTHWEST NORTH DAKOTA STREET B3 5G (P) NOKIA AEOK+AEOU STACKED 150' 51.25/ _ _ - - - _ - - - - - _ _ TIGARD, OR 97223 56.75 1 (E) 4T4R 05 AHCA TOWER B4 LTE (E)CEUNAX I50' 54' - - - - - - - - - - CMA-UOTULBULBHH-6517-17-21-21 1 (E) B66A RRH4X45-4R TOWER REV DATE DESCRIPTION DANA A 1/21/22 PRELIMS (E)cBLMaX 240 - - - - - 2 (E) 78 COAX 90'-0" 1 (E) 4T4R B5 AHCA TOWER 0 3/24/22 FOR CONSTRUCTION • G1 LTE CMA-UBTULBULBHH-6517-17-21-21 ' 54' - - 1 (E) B66A RRH4%45-4R TOWER 1 (E)$6 AWG DC 90'-0" G2 - - - - - - - - _ _ - - 1 (E)009-48-60-24-8C-EV 2 (P)#6 AWG DC 90'-0. G3 5G (P)NOKIA AEOK+AEOU STACKED 240' 51.25'/ - 56.75' 1 (E) 4T4R 012/14 AHLBA TOWER - G4 LTE/5G (P)COMMSCOPE 240' 54' 1 (E)B25 RRH4X30-4R TOWER - - - - - - - - - - NNH4-65C-R6-HG 1 (P)RRH4X25-WCS-4R TOWER NOTE: (E) - EXISTING I (P) - PROPOSED TOTALS Voltage Drop Calculations CABLE Voltage(V)= 48 Amperage(A)= 10.00 I Temperature('C)= 75 I 6 COAX 7/8' 90'-0' //• DESIGNED:JLB Power Plant to DC-6 (Jumper) DC-6 to Squid (Trunk) Squid to RRH(Jumper) Final Voltage Total Voltage 2 DC #6 AWG 90'-0" .;' DRAWN: JLB Sector Wire Size Wire Length(ft) R(c Ikf) Voltage Drop Wire Size Wire Length(ft) R(D/kf) Voltage Drop Wire Sae Wire Length(ft) R(U(dt) Voltage Drop (V) Drop(%) CHECKED: PWM Alpha 8 15 0.7780 0.2334 6 90 0.4910 0.0838 8 15 0.7780 02334 46.65 2.81 5 DC 68 AWG 90'-0• Beta 8 15 0.7780 0.2334 6 90 0.4910 0.6838 8 15 0.7780 0.2334 46,65 2.81 2 FIBER 3/8' 90'-0' JOB #:EXPIRES: 2022 Gamma 8 15 0.7780 0.2334 6 90 0.4910 0.8838 8 15 0.7780 0.2334 46.65 2.81 bMss44 21CCA06M-0141 6/30/ 1 RET 3/8• 90'-0. I.CAL.CALCULATIONS ME BASED ON D.COPPER CONDUCTORS. 2.RESISTANCE VALUES CONDUCTORS ES FOR ARE BASED ON TABLE 8 OF 1HE NEC,DIRECT-CURRENT RESISTANCE FOR CONOUclura. 3.LENGTH SHOWN IS THE LENGTH ONE-WAY TO DEVICE FINAL ANTENNA & THIS PAGE CONTAINS CONFIDENTIAL,PROPRIETARY OR TRADE SECRET INFORMATION ? CABLE SCHEDULE • EXEMPT PROM DISCLOSURE UNDER APPLICABLE LAW. I NOTES' 1. REFER TO FINAL REDS FOR FINAL RF CONPCURARON. puget:prows0Maf Aril'Tnr,HatMentgets Mnomtftun rno:+n...a o+mvA-at,. 2.REDS ID 4340407 BEING USED. FINAL ANTENNA & CABLE SCHEDULE C.4 AT&T TO ANTENNAS (PER SECTOR) JUMPERS rim r. _.__---- r~r"° CROWN �ii IN II I CASTLE 1505 WESTLAKE AVENUE NORTH,SUITE 8CU SEAT-LE:WA 98109 PROPOSED EXISTING EXISTING EXISTING EXISTING EXISTING RRH RRH (TYP) RRH (TIP) RRH (TIP) RRH NW) RRH (TYP) D IY ° .°...4i I , I ri P.MARSHALL&ASSOCIATES -. 1 I -n (2) FIBER JUMPER PAIRS -, 1 I L__ —_J I -11 1 F S P PR77 ALARM CABLE P P (TIN) L F F F P P P L P i P • F F F BU #: 856366 DC CONDUCTOR BUNDLE SCHOLLS Sc 125TH (TP) r FIBER TRUNK 12655—A SOUTHWEST NORTH i DAKOTA STREET TIGARD, OR 97223 SET OF(2)DC DC POWER TRUNKS CONDUCTOR BUNDLES MR) F 48VDC BUS INSIDE P P EXISTING POWER PLANT P P REV DATE DESCRIPTION ,of 1/21/22 PRELIMS -- ALARM 0 -03/24/22 FOR CONSTRUCTION 0 P P C DI IL RACK MOUNTED SURGE N SUPPRESSOR 7' 0 P P E O RACK MOUNTED BBU .......... POWER PLANT DC 6or 12 I 1 TOWER MOUNTED RRH SCENARIO-NOT SITE SPECIFIC JUMPER ` RRH DESIGNED:JLB JUMPER TRUNK DRAWN: JLB 1 POWER PLANT I DC-6 SQUID - RRH • CHECKED: PWM InkRRH NOTES: JOB #. '20Amn 21CCAO6M-0141 EXPIRES.6/J4/2022 I. REFER TO CHART FOR CABLE QUANTITIES,SIZES, AND LENGTHS. 0 DC WIRING DIAGRAM (PROVIDED BY OTHERS) ELECTRICAL WIRING SCALE: NOT TO SCALE DIAGRAM C-5 ANTENNA MOUNT PIPE ANTENNA MOUNT PIPE AT&T III AEQK ANTENNA ANTENNA --■ �. DOWNTILT BRACKET DOWNTILT BRACKET 1 (SUPPLIED WITH ANTENNA) (SUPPLIED WITH ANTENNA) MOUNTING BRACKET CROWN Cf:(SUPPLIED WITH ANTENNA) v1: CASTLE EI-IE 1505 WESTLAKE AVENUE NORTH,SUITE 800 SEATTLE,WA 98109 D,I 0, � .1-.16.c P.MARSHALL&ASSOCIATES AEQU ANTENNA NI ._. 3P77 BU #: 856366 MOUNTING BRACKET SCHOLLS & 125TH (SUPPLIED WITH ANTENNA) Mi r,e 12655-A SOUTHWEST NORTH DAKOTA STREET TIGARD, OR 97223 °ANTENNA DETAIL °ANTENNA DETAIL NOT TO SCALE NOT TO SCALE REV DATE DESCRIPTION A 1/21/22 PRELIMS MANUFACTURER: SITEPRO MODEL: 6CHMT 0 3/24/22 FOR CONSTRUCTION WEIGHT: 272LBS i i. 1041*Inb.' , DESIGNED:JLB DRAWN: JLB CHECKED: PWM JOB #. -'M WM1e,v1,,,1a 21 CCAU6M-0141 EXPIRES:s/w/zazz 4 EQUIPMENT THIS PAGE CONTAINS CONFIDENTIAL,PROPRIETARY OR TRADE SECRET INFORMATION DETAILS EXEMPT FROM DISCLOSURE UNDER APPUCA{LE LAW. ©Site Pro 1 6CHMT — Collar Mount °NOT USED °"`°m""°""""°""""""°`°""""den roe mw.ewrnmrnpmwbs,"'""" NOT TO SCALE C-6 MANUFACTURER: Nokia MANUFACTURER: Nokia MANUFACTURER: Site Pro 1 MODEL: Airscale AEQK MAA n77 MODEL: 474293A, 19US806081A20A MODEL: DCP12K HEIGHT: 29.5" (750 mm) MAX FPKA SUPPORTED WEIGHT: 352.7 lbs (160 kg) WEIGHT: 27.01 lbs (12.3kg) AT&T WIDTH: 17 " 450 mm DEPTH: 9.5" (242 mm) WEIGHT: 99.2 lbs (45 kg) i 17J t SIDE(TYP) H CROWN A A L 0 o 4 a ° RRH MIDDLE RRH CASTLE ' O �p _� MOUNT LOCATION '.CGS WESTLAYE AVENUE NORTH,SLIT 80C ' p SEE NOTE 1) Bp" SEATTLE.'DNA 98109 FPKA (TYP) '---- 2 I c P _ - DCP12K I�I pi !KA w AMFD 1I I (TYP.) ANTENNA/RRH —. 0 r— RRH MOUNTING PIPE P. MARSHALL&ASSOCIATES III MAST PIPE ° I II 2-3/8"MIN. ��ANTENNAO I I m I, . I� _ MOUNT PIPE mE • • Em �- RRH J ANTENNA < 0' __ 'Cr. (TYP) SIDE !WI 7 7 RF CONNECTIONS l 0 I_ WIDTH o Q •0 ° ° TOP VIEW .1. ,� rLID o /1111111w41111111PIPE TO PIPE CLAMP CHBU L: 8&5 ADDITIONAL MOUNT NOTES: ACCOMMODATES 1}" TOP VIEW 66 SCROLLS 125TH LOCATIONS (TYP) 1. INSTALLING THIRD RRH ON MIDDLE MOUNT TO 5"0 PIPE I -" LOCATION REQUIRES CAST LEGACY SPACERS. 12655—A SOUTHWEST NORTH ,c_, SECTION A-A 2. ADDITIONAL RRHs NOT SHOWN IN ISO VIEW DAKOTA STREET 0 FOR CLARITY. TIGARD, OR 97223 °Nokia Airscale AEQK MAA n77 °NOKIA FPKA — AMFD AirScale 2 FPKx Fixing Adapter °Site Pro 1 DCP12K — Pipe To Pipe Clamp NOT TO SCALE NOT TO SCALE NOT TO SCALE REV DATE DESCRIPTION A 1/21/22 PRELIMS MANUFACTURER: Nokia MANUFACTURER: Commscope MODEL: Airscale AEQU MAA n77 (DOD) MODEL: NNH4-65C-R6-HG 0 3/24/22 FOR CONSTRUCTION HEIGHT: 29.5" (750 mm) HEIGHT: 96" (2738 mm) - WIDTH: 17.7"(450 mm) , WIDTH: 25.2' (640 mm) DEPTH: 9.5" (242 mm) I DEPTH: 9.3" (235 mm) WEIGHT: 99.2 lbs (45 kg) WEIGHT: 144.4 lbs (65.5kg) / 1 x i wIII w = x DESIGNED:JLB DRAWN. JLB CHECKED: PWM JOB .——l— 1• .——�_ >aolmxx 21 CCAO6M-0141 RF CONNECTIONS RF CONNECTIONS EXPIRES:6/30/2022 h. WIDTH WIDTH L L 11 C13 1 EQUIPMENT d SECTION A-A w SECTION A-A DETAILS n p THIS PAGE CONTAINS CONFIDENTIAL.PROPRIETARY OR TRADE SECRET INFORMATION EXEMPT FROM DISCLOSURE UNDER APPUCABLE LAW. °Nokia Airscale AEQU MAA n77 (DOD) °Commscope NNH4-65C—R6—HG Da*imAni by PIS r Me stott.ont does not censtif‘rte e a `•""A"M°IFr'^e'""""^°°oes"""^st^"rtee • .0..°"""°eS°^ C-7 NOT TO SCALE NOT TO SCALE MANUFACTURER: EMERSON MODEL: F2013065 AT&T No NS.1E917 HEIGHT: 37" AT&T TECHNICAL SPECIFICATIONS WIDTH: 36" NC POWER SYSTEM FEATURES DEPTH. 30" NOMINAL SYSTEM VOLTAGE -48VDC OR .zavoc WEIGHT: 1080 lbs (w/o BATTERIES OR EQUIPMENT) CONTROL MICROPROCESSOR(ACU+) RATED OUTPUT CAPACITY- MAXIMUM CONFIGURATION SYSTEM 550 AMPS A'-48VDC PLUS REDUNDANCY 21.73 400 AMPS AT+24VDC PLUS REDUNDANCY 10.88"I RECTIFIER 2000 WATTS (41.7A) ,�,.y..ya6 DISTRERTER 120E WATTS(50A), 4V ND(1 -zavoc 36 3� L '1'`, C ROW NI (B TTIOM)10N PANEL (TOP) (3) FOR PULL+24V AND PI3) -48V BULLET POSITIONS ' POWER CABINET TO INCLUDE EMERSON SM-TEMP a — R (BOTTOM) (30) -48V BULLET POSITIONS TEMPERATURE CONCENTRATOR EN 547490 OR o 0 -- EQUIVALENT AND E CONNECTED TO BATTERY CASTLE OPEENVIRONMENTAL STRINGS BY TEMPERATURE PROBES LED LIGHT `' HEAT OPERATING TEMPERATURE -4PF TO 115'F(-40'C TO 46'C)CONTINUOUS OPERATION (PN 556155 OR PN 552992) L SWITCH EXCHANGER 00 HUMIDITY 3R TO 95%RELATIVE HUMIDITY. NON-CONDENSING pj 1505 WESTLAKE AVENUE NORTH,SUITE ECU NEW.ENCLOSURE 3R Il -' l SEATTLE,WA 98109 • ATTERTHERMAL HA UTICNS �� POWER CHAMBER 2500 WATT DOOR-MOUNTED HEAT EXCHANGER, P o o — 2RU COOLED, SPACE FOR SJRCE PROTECTION }p BATTERY CHAMBER FAN SOGA FRESH AIR VENTILATION. / D HOLDS UP TO(3) BATTERY STRINGS INTRUSION / O EQUIPMENT I SWITCH TERMIND BAR 10 orvs . PROPOSED 1/2" DIAMETER, SIMPSON STRONG-TIE O TERMINAL_BLOCK I2-POSITION PHOENIX ALARM BLOCK, 32-POSITION PHOENIX ALARM BUNCHING BLOCK / STRONG-BOLT 2 STAINLESS STEEL WEDGE ANCHOR WITH L SAFETY 3-3/4" NOMINAL EMBEDMENT (ICC ESR-3037). TO BE P.MARSHALL&ASSOCIATES DC POWER SYSTEM UL 1801 LISTED(US&CANADA), NEBS LEVEL 3 N INSTALLED IN EACH CORNER OF CABINET (4 TOTAL) . WITH MINIMUM 6.5" EDGE DISTANCE. ENCLOSURE GR-487, UL 60950, AND SEISMIC. TONE 4 COMPLIANT WEIGHT ?:• OUTDOOR NetSurer°512 816Ibs WO BATTERIES) =11 -= ==1,==' 24001bs(w/MARATHON 1e0 aH BATTERIES)PLINTH TAD i?i••E?•?,I;,? ,?'; BASE BOLT PATTERN :;:�::..... CLEARANCES .4111111111111100, ??li; RENT 6" LEFT AND RIGHT 0" REAR 1z" �COMPARTMENT w/5 BATTERY D 77 SHELVES, 10-POSITION GROUND BAR,R, && 12-PAIR PHOENIX BLOCK BU #: 856366 66.90" SCHOLLS & 125TH 629D" ` - MAX CAPACITY: I (6) —48V BATTERY STRINGS 12655-A SOUTHWEST NORTH (VLRA BATTERIES) DAKOTA STREET ) COMPONENT ISO VIEW THERMOELECTRIC TIGARD, OR 97223 T , COOLING/HEATING 0 I OEMERSON F2013065 // NOT TO SCALE REV DATE DESCRIPTION 12U A 1/21/22 PRELIMS i i 0 3/24/22 FOR CONSTRUCTION / PROPOSED 1/2' DIAMETER, SIMPSON STRONG-TIE S-RONG-BOLT 2 TOP VIEW STAINLESS STEEL WEDGE ANCHOR WITH 3-3/4"NOMINAL EMBEDMENT(ICC ESR-3037).TO BE INSTALLED IN EACH CORNER OF CABINET(4 TOTAL) WITH MINIMUM 6.5"EDGE DISTANCE. 17.50" 3.50" 3 0"0(6 TYP) 39.02' 31.81" . TYP) v v v I-0"0(6 TYP) . t. W" �,... I. I I - a a LOCK EQUIPMENT BASE FRAME a e ll o — WASHER PLATE WASHER L I I a is I I l 4.46 22.84" M. Ell - n 31.77 PE . �� .n " • DESIGNED JLB DRAWN: JLB I � • - ' �� w x CHECKED: PWM °It _ g r e r ..N ,ICE : --� AlO IPOaz 21CCAO6M-0141 �, E4PIRES:6/30/2022 1 LEFT SIDE VIEW FRONT VIEW OPTIONAL PLINTH CONCRETE SLAB EQUIPMENT DETAILS • 0 EMERSON OUTDOOR NETSURE 512 DC POWER SYSTEM (' CABINET M UTNTING TE SC E MPLATE (9 C ABINET NOT ANCHOR SC E DETAIL SCALE: NOT TO SCALE C-8 GROUNDING PLAN LEGEND: --GROUND WIRE COPPER GROUND ROD AT&T • EXOTHERMIC WELD GROUND ROD • MECHANICAL CONNECTION W/ TEST WELL �„r� CELL REFERENCE GROUND BAR: POINT OF GROUND REFERENCE FOR ALL COMMUNICATIONS EQUIPMENT FRAMES. ALL BONDS AREI MADE WITCTH . STRANDED OUND INRINGLWITH (2)COPPER �� CROWN CONDUCTORS. BOND TO GROUND RING WITH (2) #2 SOLID NEW ANTENNA NEW ANTENNA NEW ANTENNA TINNED COPPER CONDUITS (ATT-TP-76416 7.6.7). v CASTLE AND/OR RADIO AND/OR RADIO AND/OR RADIO EQUIPMENT (SEE EQUIPMENT (SEE EQUIPMENT (SEE HATCH PLATE GROUND BAR: BOND TO THE INTERIOR GROUND SHEET C-3 FOR SHEET C-3 FORT SHEET C-3 FOR RING WITH (2) #2 STRANDED GREEN INSULAIED COPPER 1505 WESTLAKF AVENUE NORTH,SUITE 800 MODEL AND MODEL AND MODEL AND CONDUCTORS. WHEN A HATCH-PLATE AND A CELL REFERENCE SEATTLE,WA 98109 QUANTITY) QUANTITY) QUANTITY) GROUND BAR ARE BOTH PRESENT. THE CELL SITE REFERENCE GROUND BAR MUST BE CONNECTED TO THE HATCH-PLATE AND T T T TO THE INTERIOR GROUND RING USING (2) #2 STRANDED GREEN D Q INSULATED COPPER CONDUCTORS. j_j INFL ../A 1 I I EXTERIOR CABLE ENTRY PORT GROUND BARS: LOCATED AT THE O I I I ENTRANCE TO THE CELL SITE BUILDING. BOND TO GROUND RING WITH A #2 SOLID TINNED COPPER CONDUCTORS WITH AN P.MARSHALL&ASSOCIATES 1 1 1 EXOTHERMIC WELD AND INSPECTION SLEEVE (ATT-TP-76416 7.6.7.2). SECTOR GROUND BAR SECTOR GROUND BAR SECTOR GROUND BAR T T T DURING ALL DC POWER SYSTEM CHANGES INCLUDING DC SYSTEM CHANGE OUTS, RECTIFIER REPLACEMENTS OR ADDITIONS, BREAKER DISTRIBUTION CHANGES, BATTERY ADDITIONS. BATTERY REPLACEMENTS AND INSTALLATIONS OR CHANGES TO DC L I _ICONVERTER SYSTEMS IT SHALL BE REQUIRED THAT SERVICES D7 7 1 1 1 - CONTRACTORS VERIFY ALL DC POWER SYSTEMS ARE EQUIPPED WITH MASTER DC SYSTEM RETURN GROUND CONDUCTOR FROM TOWER TOP COLLECTOR GROUND BAR I'I THE DC POWER SYSTEM COMMON RETURN BUS DIRECTLY BU #: 856366 CONNECTED TO THE CELL SITE REFERENCE GROUND BAR PER SCHOLLS & 125TH TP76300 SECTION H 6 AND TP76416 FIGURE 7-11 MIDPOINT GROUND BAR REQUIREMENTS. (AS NEEDED) 12655-A SOUTHWEST NORTH DAKOTA STREET TIGARD, OR 97223 TOWER EXIT GROUND BAR T I REV DATE DESCRIPTION TOWER GROUND RING I A 1/21122 PRELIMS L T T _I0 3/24/22 FOR CONSTRUCTION I I I- I EQUIPMENT GROUND RING EXISTING EQUIPMENT AREA NEW GROUND EQUIPMENT (SEE 1 SHEET C-1.2 -.FOR MODEL AND QUANTITY) DESIGNED:JLB T DRAWN: JLB CHECKED: PWM JCB #. 3/140,21 21 CCAO6M-0141 4 EXPIRES:6/30/2022 CELL REFERENCE GROUND BAR T 1 I I GROUNDING L _1 _1 J SCHEMATIC GROUNDING SCHEMATIC ^■1 TO ANTENNA COAX TO ANTENNA COAX WIPE SIZE BARNES LUG BOLT SIZE ////�j'ICOPPER/GALVANIZED GM.NO BAR COPPER/GALVANIZED GROUND BAR �6 T SOLID INSULATED D YA6C-2TC38 3/8" - 16 NC SS 2 BOLT AT&T / J f ,{7 TINNED YA3C-2TC38 3/8"- 16 NC SS 2 BOLT __ O 0 0 0.0 .........o. O O 0 0 0 0 0 0 0 0 0 0 0 0 0 T H2 STRANDED YA2C-2TC38 3/8"- 16 NC SS 2 BOLT 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 H2/0 STRANDED YA26-2TC38 3/8"- 16 NC S5 2 BOLT © 000 0000000000000000 © P1000OOoOOOooOOooOO . 0 #4/0 STRANDED YA28-2N 1/2"- 16 NC SS 2 BOLT R2 SOLID TINNED COPPER CONDUCTOR TO TOWER/SHELTER GROUND RING(2 BURNDY GROUND LUG W/LONG BARREL HEAT SHRINK RP. FOR BOTTOM GROUND BAR ONLY) (SEE CHART) (CLEAR) Rt CROWN TWO HOLE LONG BARRE_COMPRESSION TWO HOLE LONG BARREL COMPRESSION LUG(TYP) NUT(T(P) LUG (TT) LOCK WASHER(RP) CASTLE NOTES: NOTES: 1505 WESTLAKE AVENUE NORTH,SLITE S00 1. DOUBLING UP "OR STACKING"OF CONNECTORS IS NOT PERMITTED. I. EXTERIOR ANTIOXIDANT JOINT COMPOUND TO BE USEC ON ALL EXTERIOR CONNECTIONS. GROUND SEAT_E,WA 98109 • 2. EXTERIOR ANTIOXIDANT JOINT COMPOUND TO BE USED ON ALL EXTERIOR CONNECTIONS. 2. GROUND BAR SHALL NOT BE ISOLATED FROM TOWER. MOUNT DIRECTLY TO TOWER STEEL(TOWER ONLY), CONDUCTOR 3. GROUND BAR SHALL NOT BE SOLATED FROM TOWER.MOUNT DIRECTLY TO TOWER STEEL. 3. GROUND BAR SHALL BE ISOLATED FROM BUILDING OR SHELTER. BURNDY TWO HOLE LUG W/ GPM.NC BAR BOLT(SEE CHART) p IVola(TYP) °ANTENNA GROUND BAR DETAIL TOWER/SHELTER GROUND BAR DETAIL Onc BARRE ' SCALE: NOT TO SCALE °SCALE: NOT TO SCALE t / (SEE CHART) .. V 1 BARE WIRE TO BE TREATED WITH No-oX AT BOTH ENDS P. MARSHALL&ASSOCIATES NOTE: I STRANDED ALL GROUNDING LUGS ARE TO BE • ® (SEE CHART) INSTALLED PER MANUFACTURER'S SPECIFICATIONS.ALL HARDWARE BOLTS, 3/e-11 x1"'AMPEN NUTS. LOCK WASHERS SHALL BE STAINLESS RESISTANT BOLT STEEL.ALL HARDWARE ARE TO BE AS D 7 7 GRFOLLOWS! RAT WASPER, OUND #6 MIN.FROM ANTENNA (TYP)) BAR, GROUNDL LUG. FLAT WASHER AND CABLE GROUND KIT INSULATORSflip NUT, SEE NOTE z.(TYP) BU #: 856366 b ro WALL BRACKET 0 OP a ® MECHANICAL LUG CONNECTION SCHOLLS & 125TH (TR) 0 0 0 0 0 CI)SCALE: NOT TO SCALE 12655 A SOUTHWEST NORTH GROUND BAR ON SHELTER. ICE — — o DAKOTA STREET BRIDGE,OR ON ANTENNA TOWER ' 0 'a' o o �\ TIGARD, OR 97223 �1O O 0® `_'O O O/� ©� 0 O UNIVERSAL COPPER O O 000® 5 OQ OQ \� ©O O ♦� 0 GROUND BAR(4'x2E) `J LOCK WASHER STAINLESS STEEL BOLT (nP) P/N MID STAINLESS STEEL U O FLAT WASHER REV DATE DESCRIPTION TWO-HOLE COMPRESSION LUG 2-HOLE CRIMP/ (TOP) A 1121/22 PRELIMS TWO HOLE LUG,OR EXOTHERMIC—•(''''''— GROUNDING SHALL ELIMINATED� rT— COMPRESSION -� WELD TO BE USED WITH Y2RARE BARE WHEN GROUND BAR 15 CONNECTOR 11 I 0 3/24/22 FOR CONSTRUCTION CONDUCTOR WIRE TO BUILDING ELECTRICALLY BONDED TO METAL SERVICE GROUND OR GROUND PING TOWER NOTES: _ GROUND 1_ DOWN LEAD(HONE RUN)CONDUCTORS ARE NOT TO BE INSTALLED ON CROWN CASTLE USA INC. 1 r BAR TOWER.PER THE GROUNDING DOWN CONDUCTOR POLICY OAS-STD-I009I. NO MODIFICATION OR DRILLING TO TOWER STEEL IS ALLOWED IN ANY FORM OR FASHION,CAD-WELDING ON THE TOWER AND/OR IN "HE STAINLESS STEEL AIR ARE NOT PERMITTED. TTTr` FLAT WASHER STAINLESS STEEL \ MP)2. OMIT INSULATOR WHEN MOU NIINC TO TOWER STEEL OR PLATFORM STEEL BELLVILLE WASHER ' STAINLESS STEEL NUT USE INSULATORS WHEN ATTACHING TO BUILDING OR SHELTERS. (TYP) (TYP) SINGLE CONNECTOR AT GROUND BARS °GROUNDWIRE INSTALLATION GROUND BAR DETAIL STAINLESS STEEL BOLT SCALE: NOT TO SCALE °SCALE: NOT TO SCALE • STAINLESS STEEL • AA FLAT WASHER �% '5 DRAGON TOOTH WASHER (RP) - STEEL 2-HOLE CRIMP/ STAINLESS STEEL O'Ac�u1 WEATHERPROOFING KIT COMPRESSION Al.. WASHER zro sc (SEE NOTE 3) i_J ) STAINLESS STEEL STAINLESS STEEL NUT ANTENNA CABLE COAX JUMPER NOTE:MINIMUM OF 5/S NUT BELLVILLE WASHER (TP 3 iiREADS TO BE (RP) DESIGNED:JLB VISIBLE MD) ° .� TO ANTENNA (DIP) SINGLE CONNECTOR AT STEEL OBJECTS DRAWN: JLB s/s SPLIT WASHER CHECKED: PWM CABLE 2 NULL LONG (rep) BARREL TINNED STAINLESS STEEL CONNECTOR STAINLESS STEEL �/ SOLID COPPER SELF-DRILLING FLAT WASHER yy A_WEATHERPROOFING KIT LUG S/SWASHER AS FLAT MEAL SCREW J0@ A' k"STRANDED COPPER GROUND (SEE NOTE 3) (Tm) I wASnE (TYP) (TYP) 3T,."a 21CCA06M-0141 WIRE O (TMP) EXPIRES: 6/30/2022 (GROUND TO GROUND BAR) SEE CABLE GROUND HIT 2-HOLE CRIMP/ NOTES 1 &2 COMPRESSION TIN COATED SOLID CONNECTOR COPPER BUS BAR 5/S FLAT METALLIC OBJECT NOTES!DO NOT INSTALL CABLE GROUND KO AT A BEND AND ALWAYS DIRECT GROUND WIRE DOWN TO CHERRY INSULATOR (RP)ER DRAGON TOOTH WA(ttP) GROUNDING GROUND BAR. INSTALLED IF REQUIRED S/S BOLT SINGLE CONNECTOR AT METALLIC/STEEL OBJECTS DETAILS 2 GROUNDING KIT SHALL BE TYPE AND PART NUMBER AS SUPPLIED OR RECOMMENDED BY:ABLE (TYP) • MANUFACTURER. 3. WEATHER PROOFING SHALL BE TWO-PART TAPE KIT,COLD SHRINK SHALL NOT BE USED. O6 CABLE GROUND KIT CONNECTION °LUG DETAIL °HARDWARE DETAIL FOR EXTERIOR CONNECTIONS G.2 SCALE: NOT TO SCALE 7 SCALE: NOT TO SCALE 8 SCALE: NOT TO SCALE Diagram-Sector A Diagram File Name-WAT4340407_SectorAv1 jpg t toil Site Name- ORPRU0125 Location Name- SCHOLLS&125TH Market- OREGON Market Cluster- SEATTLE/OREGON/NO. ID Comments: • Sector A Ant Pos 1 Ant Pos 3 Ant Pos 4 NNH4-65C-R6-HG CNW6ryISU18HH-6517I.721-21 1 1 1 i i K 11111111 RET 1 TarflTTT1iJT100 700 100 J60 5 5 MOO I�AWAWS 1900 fl 190a85a anW9�t1 nr . v+mi e ' w.e .m .�:. .w ;�� wu� �rawc «.. l/SCaI opal 0CC IT 812!4 4M1 625 RRH4e304R '`{`{ RRfUx25-W[5:4R1.--------I �rScale R0.H4{4RR51 366A RRH4$45.IR 32(WAFL8A (1600 91i51 AHU tl0 1 6501 AW81 T—I—�J I I EI I Upr i F'bsrfjpc1c Fear C. u,q2 �n*. opts het U ��her I Y.�,tLer vprr yat Opr.0 riLb r----, iii ''''''''... ill , I .. Opt13 3;MEt . Oct c r der — - OpUe F'Cer atch Plate illiiiiii riberTrunt. Flber`IvnkII - NE IM aII II = = la B r aim 1 Baseband Unit Baaeaa=G Uret Power Plant (ORtU01251 (OR02N00525) 1 THIS PAGE CONTAINS CONFIDENTIAL,PROPRIETARY OR TRADE SECRET INFORMATION EXEMPT FROM DISCLOSURE UNDER APPLICABLE LAW. Aigle afrprWr![tl Cy Ara r Ma Mt:mecR*CI MStueghNts 4,41.33e3.3113.0333333 03**W, Diagram-Sector B Diagram File Name-WAT4340407_SectorBvl.jpg A toll Site Name- ORPRU0125 Location Name- SCHOLLS& 125TH Market- OREGON Market Cluster- SEATTLE/OREGONINO. ID Comments: Sector B Ant Pos 1 Ant Pos 3 Ant Pos 4 NNHn 55C Rfi f f C,aIJBNl8Ut8HX-651]-1131 21 • PTIT F T T: ILTLi - Ti IT i''. El I ill 0.FrT PET TEE=-Jr A�Si E�"r�am TOO T00 100 I, CS WR5 irlis W —P.W AMU1900: 1900 ism ow 950 850 B90 650 p —A - ME IM ME rats M eta.'. . r ` ' '' STScakbJ +. zi-.:. 9 m PRXAXZSWCS-9ft ; - e.�s �tt.,� 1Pna fop.* Optl Rite Ottr Fiber 009w fher 1piu cu Gft" ttv_". OptA ,tier F)bCB pLSFher OptleFit .. .---------j--1 nubs i• — — COStS 0 ber 'Opty riher Optic fiber atch Plate IN Fine!■Yrceb fiber 11055 ■ a r .—.. I r r r B seband1095001 Unit I Baseba109090 d0 that It1RI.001?S4 R)ADN0P0325) THIS PAGE CONTAINS CONFIDENTIAL.PROPRIETARY OR TRADE SECRET INFORMATION EXEMPT FROM DISCLOSURE UNDER APPLICABLE LAW. ayrrylne pppf[bb,ATSF rnh MNNm.M bats one COMMON enpw OtMy**Omarf Diagram- Sector C Diagram File Name-WAT4340407_SectorCv1:jpg 'toll Site Name- ORPRU0125 Location Name- SCHOLLS& 125TH Market- OREGON Market Cluster- SEATTLE,!OREGON/NO. ID Comments Sector C - Ant Pos 1 Ant Pos 3 Ant Pos 4 NNH4 fiSC Rti-HC '. ..... [MA UeR9 ell 3HH 9517-SiwT121 R I( i x AEQK x %� r Ix ice, ..! A II'1 i i. x N �x H Ye z RLI Lir_�—.—J RRC' ims ai ' 6 ...7 liT„..2.L.T,„ 1 [------ AV, 700 xao toowcs 700Hit r......Hsr___IT ar -wGy WCS wcs AEOU �AV! 1900 1900/900 1900 950 d50 950 85o wW AWS. �J L I 1 1111 pv , LLii1 1 i _..�. ,+ ,,,. ,w UrScate Mat RAH,TM a 4 an RRH4K304R RRH4X35-VE BR t t e ARM 4T4R n1 aSEA RRH4%45'4a 31 (19401 fRR'5t' , AHD l (AVM 1 ',Mx 1 Ott..r'it¢,090 1 OCt GCOCf bt., Fl.la. �'t si1rxI Iiiim(.O to ieupCt. Optic Fiber Optic line Opt,c£ter atch Plate limo Fttitr Trunk: Film TPt!il Baseband Unit Baseband Unit Power Plant (00c00135) (OR00,100012S) 4 THIS PAGE CONTAINS CONFIDENTIAL,PROPRIETARY OR TRADE SECRET INFORMATION EXEMPT FROM DISCLOSURE UNDER APPUCAELE LAW. p rimaser MetMra 0 Arai:rtii note.eent san atetaasra9N n+4:setnrp an0613 tr 41ya OFFICE COPY OFFICE COPY CITY OF TIGARD, REVIER CODE COMPLIANCE Approved: ) OTC: [ Permit ##: ,f3vpa0aa— o o n 9 P Address: / c 5"C.s.v N FJ c. 1{0,t... Suite #: By, ) J Date: t-} - 19 '�Z SPEW' Stataoi .�� . ❑ Conc-e'e ❑ gotrn ! ... ❑ Spe!• ❑ Par J Str. ; ,r; 17GcC1 G Ir Hi ti ❑ Reinfca.:. ❑ irsui l �! Sprs,; ❑ Snotcra:i_ ❑ Special a"; ,• h,;a [] Smok v{hcr Inc a .,i.. ...-.___..._....