Loading...
BUP2023-00171 (2) FOR OFFICE USE ONLY—SITE ADDRESS: .1500 l D v e.d 1 SO This form is recognized by most building departments in the Tri-County area for transmitting information. Please complete this form when submitting information for plan review responses and revisions. This form and the information it provides helps the review process and response to your project. City of Tigard • COMMUNITY DEVELOPMENT DEPARTMENT ■illig ~ Trans mittal Letter T I G,A It D 13125 SW Hall Blvd. • Tigard, Oregon 97223 • 503.718.2439 • www.tigard-or.gov TO: DATE RECEIVED: DEPT: BUILDING DIVISION RECEIV D FROM: K 0, yv, F FR 2 7 2021' COMPANY: Ka/7 (on 41 y' u c-- 71-,'oi--f .CITY OF TIG/�RU at I,1 ninlr nhi crnt PHONE: So 3"- 3` 8 6 7 l ' - By: .. . EMAIL: Kci. de ,7 04 y a(4 op . Cd;/-7 RE: 7500 S kJ D -I- 0,2-4-6 s-14-(S° 4P 3- oo (71 (Site Address) (Permit Number) fly - irc�1,`?df,7 (Projec name or subdivision name and lot number) ATTACHED ARE THE FOLLOWING ITEMS: Copies: Description: Copies: Description: Additional set(s) of plans. T5 Revisions: rr.-'rvc s bear We(I 4 ,vi 5 4//wew Cross section(s) and details. Wall bracing and/or lateral analysis. Floor/roof framing. Basement and retaining walls. Beam calculations. Engineer's calculations. Other(explain): REMARKS: FOR OFF CE USE ONLY Route o Permit Technician: Date: 3-3-- .1 Initials: 1 Fees Due: Yes ❑ No Fee Description: Amount Due: J /-,I r pi .--NA rca-V i e,,./ $ 9 0 -- $ $ $ Special Instructions: Reprint Permit (per PE): ❑ Yes N No ❑ Done Applicant Notified: i Date: -1'74/Pt Initials: .. . I:\Building\Forms\TransmittalLetter-Revisions 073120.doc gu('2o23-ootl REVISION Butler 12501 SE Scott Creek Lane,• F , , Happy Valley,Oregon 970t1!6 �^.,s/ a � Consulting, Inc. (503)658-0200 mark@bciengineering.com <-. 7 2024 CITY OF TIGARD STRUCTURAL CALCULATIONS VILDINGDNISION Kyuramen Tenant Improvements 7500 SW Dartmouth Street Tigard, Oregon f CO PV Kaly Construction&Design Job Number 27-0923-127 s.okucTURA4 PROrFss 14855 I OREGON ,,ir E . B y-c EXPIRES 12-31-2025 February 21, 2024 Contents: Project Overview 1 Configuration 2 Vent Hoods 3 Torii Display 4 Honeycomb Seating Enclosure 5 Lateral Loading 6 Shear Walls 9 Shear Wall Footings 11 Connection to Roof Framing 12 Job No. 27-0923-127 February 21, 2024 Kyuramen Tenant Improvement Page 1 Kaly Construction& Design STRUCTURAL CALCULATIONS DESIGN CRITERIA: These revised calculations are for the structural requirements of the tenant improvements for Kyuramen in the existing building located at 7500 SW Dartmouth Street in Tigard, Oregon. The structural aspects of the work includes the following: 1. Framing for a new vent hood 2. Support of new architectural features. 3. Restoring the structural integrity of the lateral force resisting system in the north-south direction due to the removal on an interior shear wall. All new structural components were designed in accordance with the 2022 Oregon Structural Specialty Code and ASCE 7-16. See the architectural plans by Kaly Construction &Design for all plan dimensions and finishes. Loading: Roof 12 psf DL + 25 psf Snow Exterior walls 14 psf Exterior walls w/Veneer 49 psf Interior partitions 8 psf Vent Hood#1 1,003 lb Vent Hood#2 476 lb Vent Hood#3 898 lb Torii Display 200 lb Honeycomb seating Enclosure 6,745 lb Assumed Soils Properties Allowable Soil Bearing 3,000 psf per original construction documents. Seismic: Base Shear: E = F SDs /R W Eq 12.14.8, ASCE 7-16 simplified design procedure Site Class D Seismic Design Category D F = 1.0— 1-story Building Ss = 0.940 Per USGS Seismic Hazard map for Si = 0.391 JLat. 45.4530°, Long 122.7537° SDs = 2/3 FaSs = 2/3 x 0.940 x 1.20 = 0.752 R = 3.5 Ordinary Moment Frame of original construction W = Structure Weight E = (1.0)(0.752)(1.0)/3.5 W = 0.215 W Wind: Use simplified method per ASCE 7-16 Section 28.5 98 mph 3 second gust per OSSC Table 1609.3 Risk Category II, Exposure B Load Combinations: D + L+ (0.6W or 0.7 E) 0.6 D±(0.6W or 0.7E) Sheet 2 Butler Job No.27-0927-127 Project Kyuramen Tenant Improvement Date 2/21/24 Consulting, Inc. Client Kaly Design& Construction Subject Configuration By MEB Rev Description By Date I I I I 0 I I I I �o i , i 1 SHEAR WA5L 1 i 1 O — — j i TO REMAIN j. I' ._.............L.L 0 III � � 1 . I I . I . I . I I I I ' I I . I I I I I I I I I I I I I I Erl I I I I , NWSIARYthLtrll I I I O — — — 1,,, H'S6x5.,T ES EL — C..LUM EAD — I O H11:T0I i : ii iiiiii iiii i • i i 1111111 NESH R WILL w/HS x5TUB STEEL 1 1 II mil mil I I COLUMN FAA ENC i i i ° 4 IL _ - _ i - . - � b b b b b b b b b ,o ROOF FRAMING PLAN f I I I I ) I 'NT H000 VENT Hi OD E i VENT OOD t ! 1 rr . Lj. • 7 I I I JAPANISE TORII D PLAY i___.__1___+______k_ _____ 1 ! 1 ! ! ! 1 ___1___. _____...4._____ � ! I o NEWISHEAR WALL w/ I �HSSix5xsTUB STEEL I A'b I COL MN EA EN 9 EI CLOSURE Y 0 HERS = I — I i • I I j KYURAMEN FLOOR PLAN Sheet 3 Butler Job No. 27-0923-127 Project Kyuramen Date 9/29/23 Consultin , Inc. Client Kaly Construction & Design Subject Vent Hood By MEB Vent Hoods Vent Hood 1 1,003 lb Customer Side Vent Hood 2 476 lb Prep Side - Left Vent Hood 3 898 lb Prep Side - Right Hang from added ceiling joists between partition walls CO u m m Vent 1 Vent Hood 2 � Hood 3 Vent _ . _ Hood 1 B3 Beam B1 B2 B3 Span = 9.50 ft 9.50 ft 19.00 ft OH = - ft - ft - ft P1 = 119.0 lb VH3 224.5 lb VH2 250.8 lb VH2 X- P1 = 5.00 ft 5.00 ft 6.50 ft P2 = - lb - lb 250.8 lb X- P1 = - ft - ft 18.33 ft R1 = 56.4 lb 106.3 lb 173.8 lb R2 = 62.6 lb 118.2 lb 327.7 lb Section 800S200-33 800S200-33 (2)800S200-33 MMax= 281.8 ft-lb 531.7 ft-lb 1,129 ft-lb fb = 2,576 psi 4,860 psi 5,161 psi Ox = 0.026 in 0.050 in 0.210 in = 2L/1.086 Use 800S200-33 Use 800S200-33 Use (2) 800S200-33 Sheet 4 Butler Job No. 27-0923-127 Project Kyuramen Date 10/1/23 Consultin , Inc. Client Kaly Construction &Design Subject Seismic Anchorage By MEB Seismic Anchorage Seismic Loading FP = 0.4R S„sW (1 + 2z/h) P P aP = 1.00 RP = 2.50 1p = 1.00 Fa = 1.194 per USGS Seismci Hazard Map for SS = 0.940 a Lat 45.4530°, Long 122.7537° Sos = 0.770 h = 22.00 ft Vent Hoods Vent Hood 1 Vent Hood 2 Vent Hood 3 W = 1,003 lb 476 lb 898 ;b z = 8.67 ft 8.67 ft 8.67 ft RT°p - 0.7FP = 155 lb 73 lb 138 lb RTOP = 30.5 lb 14.5 lb 27.3 lb RBOt = 46.9 lb 22.2 lb 42.0 lb `" I V MMax = 406.2 ft-lb 192.7 ft-lb 363.6 ft-lb 00 Section 550S162-43 550S162-43 550S162-43 RBA ao fb = 7,157 psi OK 3,396 psi OK 6,408 psi OK Japanese Torii Decoration Designed by others Design attachment to wall Component Section Length ! Unit Wt Qty ' Weight Height 1 Wt x Ht 1 Curved Top Boards4x12 15.5 9.57 ' 2 ' 297 10.29 3,053 Top Beams 8x14 12.21 24.6 1 1 300 9.56 2,871 Mid-Beam 8x8 1 10.5 ! 13.7 1 144 6.875 989 Posts '12x12 i 10.25 1 32.1 2 1 658 ' 5.125 3,373 Total 1,399 7.35110,286 Trib Wt = 699 lb RTOP-. z = 7.35 ft 0.7FP = 80 lb Brace @ ea post cV0 ES i i .c V RTOP = 13.4 lb `o. RBOt = 26.8 lb RB. r-- MMax = 197.0 ft-lb Stud 550S162-43 fb = 3,471 psi OK Sheet 5 Butler Job No. 27-0923-127 Project Seismic Anchorage Date 10/1/23 Consultin , Inc. Client Kaly Construction & Design Subject Vent Hood By MEB Seismic Anchorage (Cont) Honeycomb Seating Enclosure Framing designed by others Design attachment to floor Component Section Length Unit Wt Qty Weight Height Wt x Ht j (ft) j (plf) j (lb) (ft) ft-lb Upper Steel Frame1C4x7.25 23.94 7.25 2 347 9.52 3,305 Upper Joists 2x4 21.21 1.3 8 221 11.5 2,537 Upper Cover 1/2" P/W 9.28 2 1 19 12.9 239 Upper Rear Cover 1/2" P/W 43.1 2 1 86 9.52 821 Lower Steel Frame C4x7.25 17 7.25 4 493 3.52 1,735 Lower Joists 2x4 17 1.3 12 265 2.92 774 Lower Cover Joists 2x4 3.375 1.3 12 53 6.19 ; 326 Lower Cover 1/2' P/W 16.17 2 1 32 6.4 207 Lower Rear Cover 1/2" P/W 42.24 2 1 84 3.04 257 Lower Floor Joists 2x4 17 1.3 12 265 0.15 40 Lower Floor Cover 1/2" P/W 16.17 2 1 32 0.33 I 11 Total 1,898 5.40 10,251 Int.Cover 2x4 Deck 8.82 7.25 1 4 6.375 28 Int. Floor Frame C4x7.25 3.21 7.25 4 93 9.73 906 Int Floor Joists 2x4 3.21 1.3 11 46 2.92 134 Int. Floor 1/2" P/W 15.38 2 1 31 3.17 98 Int. Rear Cover 12x12 41.86 2 1 84 5.92 496 Stairs 2x Treads 13.52 8 1 108 1.59 171 Railing 2x 20.55 4 2 164 4.13 678 Total Interior 530 4.73 2,511 Ends Interior Trib Wt = 949 lb 1,214 lb z = 5.40 ft 5.26 ft w Fp (Ult) = 174 lb (Ult) 221 lb (Ult) MOT = 5,126 ft-lb 6,381 ft-lb X = 2.67 ft-lb 2.67 ft-lb RDA = 474.4 ft-lb 607.0 ft-lb Re. • RE = 1,920 lb 2,390 lb X R 1.1 D + E = 2,442 psi OK 3,058 psi OK R R R 0.9D - E = (1,493) psi OK (1,844) psi OK Use (2) 1/2" x 4" screw anchors See Simpson Anchor designer printout in appendix Sheet 6 Butler Job No 27-0923-127 Project Kyuramen Date 2/19/24 Consulting, Inc. Client Kaly Construction & Design Subject Lateral Loading By MEB SEISMIC LOADING: Design new 'shear walls to replace the capacity of the removed shear wall. The existsing wall carries roughly half of the north-sout lateral loads. 2 new shear walls have been designed to restore that lateral force resisting system. 10' of the existing wall is to remain in place and will carry a greatly reduced lateral load. Use Simplified lateral Force Analysis Procedure from ASCE7-16, 12.14.8 Ss = 0.940 per USGS Seismci Hazard Map for Si = 0.405 Lat 45.4530°, Long 122.7537° Fa = 1.20 Site Class D, Table 14.4 Fv = null Site Class D, Table 11.4-2 SMs = Fa Ss = 1.128 Sps = 2/3 SMs = 0.752 Seismic Design Category"D" E = F Sps / R W Eq 12-14.11, simplified analysis procedure F = 1.00 1-story building (considering basement as a floor) j R = 3.5 Per original structural drawings by BCRA for ordinary steel moment frames E = 1.2x0.729 /3.5W = 0.215 W Vseis = 0.215W x 0.7 = 0.1504 W (Allowable Stress Design) Estimated Weights Roof: EISF Walls Veneer Walls Membrane 1 psf 1/2" P/W 2 psf 1/2" P/W 2 psf Insulation 4 psf 5/8 GWB 2.5 psf 5/8 GWB 2.5 psf Decking 2.2 psf 2" EIFS 2.5 psf Veneer 39 psf Trusses 2 psf (2) Studs 2.5 psf Steel Studs 1.25 psf Beams 2 psf Insulation 4 psf Insulation 4 psf Total 11.2 psf Total 13.5 psf Total 48.75 psf Use 12.0 psf Use 14.0 psf Use 49 psf Component Length Width Unit wt Wt Story (ft) (ft) (psf) (kips) Shear Roof Roof 199.67 60.08 12.00 144.0 Canopies 274.00 5.50 8.00 12.1 South Wall EIFS Wall 202.33 14.74 14.00 41.8 Storefronts 158.83 3.27 8.00 4.2 Veneer 51.50 12.09 49.00 30.5 South Wall EIFS Wall 201.33 12.21 14.00 34.4 Storefronts 250.00 2.94 8.00 5.9 Veneer 79.00 2.94 1 49.00 1 11.4 Partitions 549.50 11.50 8.00 1 50.6 Partitions 118.00 3.13 8.00 3.0 Subtotal 33.00 i 337.6 50,777 Sheet 7 Butler Job No 27-0923-127 Project Kyuramen Date 2/18/24 Consulting, Inc. Client Kaly Construction &Design Subject Lateral Loading By MEB Wind Loading Use simplified wind load method per 28.5 ASCE 7-16 Ph = XKn Ps3o Eq 28.501 = 1.0 Mean Roof Height< 30') Kn = 1.0 Topographic factor V = 97 mph for Washington County per OSSC Table 1609.3 for Risk Category II Roof Pitch Flat p30 = Zone A 14.33 psf Zone B 7.42 psf Zone C 9.52 psf Zone D 4.40 psf Conversion to ASD 0.60 Least horizontal dimension 62.67 ft a = 6.27 ft South Elevation Flat Roof X Wall Roof ph Zone A/B (ASD) ph Zone C/D (ASD) w� = 0 15.96 - 137.24 plf 91.16 plf w2 = 27.5 16.57 - 142.49 plf 94.65 plf w3 = 0 17.19 - 147.82 plf 98.19 plf w4 = 6 23.27 - 200.10 plf 132.92 plf w1 �� W2 W3 w2 w4 t 106'-1" t2'-4-111' 85'-1" 5,572 lb 5,275 lb 338 lb 5,465 lb 6,167 lb Sheet 8 Butler Job No 27-0923-127 Project Kyuramen Date 2/19/24 Consulting, Inc. Client Kaly Construction & Design Subject Lateral Loading By MEB Lateral Load Distribution Distribute Lateral Loads by tributary area Redundancy Factor p = 1.0 for simplified method Wall Wind Seismic VW,ii Trib Area I Load (Ib) (sq ft) (lb) (Ib) North-South Direction Wall 1 5,572 3,361 13,055 13,055 Wall 5.8 5,275 3,584 13,921 13,921 Wall 6.0 338 213 826 826 Wall 6.2 5,465 2,937 11,408 11,408 Walk! 10 6,167 2,978 11,567 11,567 Total E-W 22,816 13,071 , 50,777 Compare to oirignal design Grid 6 shear wall Sureboard 200 #10 screws @ 3" spacing attached to 18 ga studs Capacity 858 plf Length 30.21 ft Capacity 25,920 lb vs 26,155 lb for walls 5,8, 6.0 & 6,2 within 1% OK Butler lob No 27-0923-127 Project Kyuramen Sheet 9 Date 2/19/24 Consulting, Inc. Client Kaly Construction&Design Subject Shear Walls By MEB Shear Walls Wall Unit Shear v; = V;/ EL; Shear Wall Plate Attachment: Overturning MOT = L; v; H pnb = C mf d t F„ AISI Eq J3.3.1-1 Overturning Resist. MRes = WDL L;2/2 d = 0.5 in Net Uplift Pup;;h = (MOT-0.6 MRes)I(L;-3") t = 0.054 in H = Height of wall panel C = 3.000 for d/t < 10 L; = Length of wall panel mf = 1 wm_ = Dead load trib to wall F„ = 62 ksi S2 = 2.5 Pnb = 2,009 lb Shear Wall Schedule Type Sheathing Panel Nailing Capacity Plate Attachment Edges 'I Field (ptf) Anchor Bolts Existing Sure-Board 200 #10 @ 3" #10 @ 12" 842 5/8"4)@ 8" New P/W 7/16" Plywd, ea side #10 @ 4" 8d @ 12" 988 s/a"4)screw anchor @12" Adjust seismic shear capacity by 2L/H for H/L < 3.5 Roof DL 12 psf Wall DL 8 psf Parameter Wall 5.8 I Wall 6 1 Wall 6.2 "Wind (Ib) 5,275 338 5,465 Vseis (lb) 13,921 826 11,408 Wall Length Li(ft) 16.50 10.00 14.00 Vi(lb) 13,921 826 11,408 Unit Shear Wind(plf) 319.7 33.8 390.3 Unit Shear Seis(plf) 843.7 82.6 814.8 Wall Type New P/W Existing New P/W Wall Height H (ft) 23.00 23.00 23.00 Adjusted allow Seis shear 1,064.0 746.1 1,064.0 MOT (ft-lb) 320,186 19,009 262,373 Roof Trib Width (ft) - 8.00 - Wall Trib Height(ft) 23.00 23.00 23.00 MRes (ft-lb) 25,047 9,200 18,032 Pup (Ib) 18,779 1,384 18,295 Simpson Holddown S/HDU9 S/HDU6 S/HDU11 Sheet 10 Butler Job No 27-0923-127 Project Kyuramen Date 9/16/13 Consulting, Inc. Client Kaly Construction & Design Subject Shear Wall Strapping By MEB Shear Walls End Struts Design vertical end chords for expected strength VE of shear wall < D,,Vn VE Expected strength VE + 1.8 V, Wall Wall 5.8 WaIl 6 Wall 6.2 vn = 988 plf 842 plf 988 plf L = 16.50 ft 10.00 ft 14.00 ft VE = 1.8Vn L = 29,344 lb C=3 15,156 lb 24,898 lb = no Vn = 34,803 lb 2,066 lb t=I 28,519 lb Height 23.00 ft 23 ft 23 ft MOT = 674,903 ft-lb 47,524 ft-lb 572,645 ft-lb MRes (ft-lb 25,047 ft-lb 9,200 ft-lb 18,032 ft-lb Chord Comp 40,903 lb 4,752 lb 40,903 lb L 1 Uplift 39,992 lb 4,200 lb 40,130 lb R R Holdown HSS6x5x5/16 S/HDU6 HSS6x5x5/16 Member HSS6x5x5/16 (2)600S162-43 HSS6x5x5/16 Fy = 42,000 psi 33,000 psi 42,000 psi A = 5.85 in2 0.826 in2 5.85 in2 r = 1.95 in 2.059 in 1.95 in KI/r = 141.54 134.05 141.54 Fe = 14,287 psi 15,929 psi 14,287 psi Fir = 0.877 Fe = 12,530 psi 21,391 psi 12,530 psi Pn = Fcr A/ 1.67 = 43,892 lb OK 10,580 lb OK 43,892 lb OK Anchor Bolts Anchor Bolts (4)PAB7x15 5/8" 4)x 10"embed (4)PAB7x15 Steel Strength 80,884 lb 9,833 lb 80,884 lb Concrete Breakout 40,785 lb 5,929 lb 40,785 lb Adhesive 51,219 lb 7,141 lb 51,219 lb DCR 0.981 < 1.0 OK 0.708 < 1.0 OK 0.984 < 1.0 OK Use HSS6x5x5/16 Use(2)600S162-43 Use HSS6x5x5/16 w/(4)PAB-12"embed w/5/8" 4)x10"embed w/(4)PAB-12"embed Shear Wall Connection to Column Stitch weld end steel stud to column w/ 2-12 1/8"fillet weld each side 1/8" Weld capacity = 544 plf Req'd weld length = 75.2 in Use 2-12 x 1/8" stitch weld ea side = 2" x 2 sides x 23' = 92" OK Top Plate Connection Use C6x10.5 cont. steel channel. VE = 1.8Vn L = 1,778 plf #10 screws in 54 mil track 370 lb Use#10 screws @ 4" o/c in 2 rows Butler Sheet 11 Job No 27-0923-127 Project Kyuramen Date 2/19/24 Consulting, Inc. Client Kaly Construction& Design Subject Anchor Bolts By MEB Shear Wall Footings Wall 5.8 Footing MOT = 320,186 ft-lb ( ASD) Component Length Width Height Unit DL Weight CG Wtx CG (ft) , (ft) (ft) (psf) (Ib) (ft) (ft-lb) Shear Wall 16.50 1.00 23.00 8 3,036 13.00 I 39,468 Footing 26.00 3.33 2.00 145 25,108 13.00 326,407 Slab 28.00 2.00 ; 0.33 , 2,680 13.00 34,835 Total i j 30,824 j 13.00 I 400,709 > MOT OK Soil Bearing P/A +/ Mc/I Max Min 356 853 1,209 -497 IPDL MOT = PDL (L/2 -X/3) 1< ( °Max L = 26.00 ft X = 1.5L-3MoT/PDL= 7.84 ft < L QMax = 2 PDL /X/W = 3,933 psf< 1.33 x 3,000 OK! Wall 6.2 Footing MOT = 262,373 ft-lb ( ASD) Component Length ' Width Height Unit DL Weight CG Wtx CG (ft) I (ft) (ft) (psf) (lb) (ft) (ft-lb) Shear Wall 14.00 I 1.00 23.00 8 2,576 10.50 27,048 Footing 21.00 I 3.33 2.00 145 20,280 10.50 1212,937 Slab 23.00 2.00 0.33 145 2,201 10.50 23,112 Total 1 25,057 10.50-- - -263,096 > MOT OK Soil Bearing P/A +/ Mc/I Max Min 358 1,072 1,430 -714 1PDL MOT = PDL (L/2 -X/3) QMax L = 26.00 ft X X = 1.5L-3MoT/PDL= 7.59 ft < L QMax = 2 PDL /X /W = 3,303 psf< 1.33 x 3,000 OK! Sheet 12 Butler Job No 27-0923-127 Project Kyuramen Date 2/19/24 Consulting, Inc. Client Kaly Construction & Design Subject Anchor Bolts By MEB Connection to roof diaphragm Design strut to span between exist truss and drag beam P� j L1 T Span R2 Grid 5.8 Grid 6.2 Span 6.67 ft 6.67 ft L1 = 4.17 ft 3.88 ft VE = 29,344 lb 24,898 lb Struts 3 3 P / strut 9,781 lb 8,299 lb R1 = 3,668 lb 3,476 lb R2 = 6,113 lb 4,824 lb MMaX = 25,471 ft-lb 18,692 ft-lb Section C10x20 C10x20 f„ = 1,613 psi OK 1,273 psi OK fb = 19,345 psi OK 14,196 psi OK Ox = 0.089 in OK 0.065 in OK Use C10x20 Channel Use C10x20 Channel