Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Report (6)
OFFICE Copy FPS202/-00 /3G 900 sct/ 0iaCtK ' �'Cc) RECEIVED Western States N°� °� CITY OF TIGARU Fire Protection Co. BUILDING DIVISION Pwteet 4aie4 POWERED BY API Group 17500 SW 65th Avenue Lake Oswego, OR 97035 Phone (503) 657-5155 Fax (503) 657-5182 Fire Protection Product Submittals Life Stance Health TI 9755 SW Oak Street Suite 500 Tigard, OR 97223 WSFP Project #LG5929 Prepared by: Alexander Funk Designer Western States Fire Protection Co. 17500 SW 65th Avenue Lake Oswego, OR 97035 Phone: (503)305-3018 Email: Alexander.Funk@wsfp.us Web: www.wsfp.com November 4, 2021 Bulletin 014 August 2021 I Z co p Model Fl FR Series !tellable Quick Responseo Glass Bulb Sprinklers n C U, Model F1 FR56 Sprinkler Types I "o ' Standard Spray Upright Standard Spray Pendentibli Conventional Upright/Pendent Vertical Sidewall fi Horizontal Sidewall o�4 Model F1 FR56 Recessed Sprinkler Types Upright Pendent Y n e Y Standard Spray Pendent ,, - ' Horizontal Sidewall ' Model F1 FR56 Concealed Sprinkler Types 4 f; Standard Spray Pendent Model F1 FR42, F1 FRXLH & F1FR28 Sprinkler ' ' Types Standard Spray Upright Vertical Sidewall Horizontal Sidewal Recessed Pendent/F1/F2 Standard Spray Pendent , . w www Model F1 FR40 Sprinkler Types Standard Spray Pendent i iT �� Model F1 FR42, F1 FR40, F1 FRXLH & F1 FR28 � K � ff Recessed Sprinkler Types k A . ,' .A.,- ,1 Standard Spray Pendent +' .; ,4 .,. dl':'...•.:1' Model F1FR56LL& F1FR42LL Low Lead Sprinkler RecessedConceale Recessed Types Horizontal Sidewall Pendent Pendent/FP Standard Spray Pendent with less than 0.25% Lead Con- _ tent Listing &Approvals (0 The following organizations provide Listings or Approvals for various Model F1 FR series sprinklers. See the Design and Installation table in this Bulletin for information on specific XLH Upright XLH Pendent XLH Recessed listings and approvals applicable to each sprinkler. Pendent F1/F2 1. Underwriters Laboratories Inc.and Certified for Cana product Description da (cULus) in accordance with ANSI/UL199. %= 2. FM Approvals (FM) Reliable Model F1 FR series sprinklers 3. Loss Prevention Certification Board (LPCB) are quick-response automatic sprinklers ' 4. VdS Schadenverhutung GmbH (VdS) with a glass bulb thermal element. Model _'1 k, 5. Underwriters Laboratories Inc. and Underwriters Lab- F1 FR series sprinklers are Standard Spray oratories of Canada Certified for Health Effects to NSF/ sprinklers,with the exception of the Model ANSI Standard 61 Annex G (ULH) F1 FR56 Conventional sprinkler which is XLH Recessed 6. EC Certificate: 0786 CPD 40239 (RA1414), 0786- an Old-style/Conventional sprinkler. Pendent FP CPD-40251 (RA1425), 0786-CPD-40252 (RA1475) The Model F1FR Series automatic sprinklers utilize a 3.0 mm frangible glass bulb. These sprinklers have demonstrated (EC) 7. (EC)WaterMark certified. Certificate Number 23347. (WM) response times in laboratory tests which are five to ten times faster than standard response sprinklers. This quick response UL Listing Category enables the Model F1 FR Series sprinklers to apply water to a Sprinklers,Automatic&Open (VNIV) fire faster than standard-response sprinklers of the same tern- Quick Response Sprinkler perature rating. The glass bulb consists of an accurately controlled amount of special fluid hermetically sealed inside a precisely manufac- tured glass capsule. This glass bulb is specially constructed to provide fast thermal response. Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 At normal temperatures, the glass bulb contains the fluid in Model F1 FR Series sprinklers must be installed with the Reli- both the liquid and vapor phases.The vapor phase can be seen able sprinkler installation wrench identified in the Design and as a small bubble.As heat is applied,the liquid expands,forcing Installation Information table in this Bulletin. Any other wrench the bubble smaller and smaller as the liquid pressure increases. may damage the sprinkler. A leak tight sprinkler joint can be Continued heating forces the liquid to push out against the bulb, obtained with a torque of 8 to 18 lb-ft(11 to 24 N-m). Do not causing the glass to shatter,opening the waterway and allowing tighten sprinklers over the maximum recommended installation the deflector to distribute the discharging water. torque. Exceeding the maximum recommended installation Model F1 FR Series sprinklers provide a wide range of options torque may cause leakage or impairment of the sprinkler. where quick-response,glass bulb sprinklers are used: Recessed Sprinklers • Pendent, recessed pendent, upright, horizontal side- Model F1 FR Series Recessed sprinklers are to be installed wall, and vertical sidewall deflectors as shown in Fig. 1, Fig.2,or Fig.3,as applicable to the specific • K-factors of 2.8 (40 metric), 4.0 (57 metric), 4.2 (60 model being installed.The Recessed Escutcheon Data table in metric), and 5.6 (80 metric) the Bulletin identifies the only recessed escutcheons that are • Flush, recessed, and concealed installations permitted to be used with each Model F1 FR Series Recessed See the Design and Installation Information table in this Bul- sprinkler.The use of any other recessed escutcheon will void all letin for information on the approvals and availability of specific approvals and negate all warranties. Model F1 FR series sprinkler configurations. Concealed Sprinklers Model F1 FR Recessed Pendent and Recessed Horizontal Model F1 FR Series Concealed Pendent sprinklers are to Sidewall sprinklers are required to be used with Reliable Model be installed as shown in Fig. 4 or Fig. 5, as applicable to the F1, F2, or FP recessed escutcheons. See the Recessed Es- selected cover plate. Model F1 FR56 Concealed Pendent and cutcheon Data table in this Bulletin for listing and approval infor- Model F1 FR56LL Concealed Pendent sprinklers have a facto- mation with each specific Model F1 FR series sprinkler. Model ry-installed Model CCP cup.A protective cap is installed at the F1 and F2 recessed escutcheons, shown in Fig. 1 and 3, are factory that should remain on the sprinkler until the sprinkler is a friction fit assembly allowing for 3/4-inch (19mm) and 1/2- installed and should then be reinstalled on the sprinkler until the inch(12.7mm)of adjustment, respectively. Model FP recessed cover plate is installed.The concealed sprinkler assemblies are escutcheons, shown in Fig. 2, provide a 1/2-inch (12.7mm) completed by the installation of a Model CCP push-on/thread- threaded adjustment. off cover plate assembly.The cover plate and sprinkler cup as- Model F1 FR56 Concealed Pendent and Model F1 FR56LL semblies are joined using a cover plate skirt with flexible tabs Concealed Pendent sprinklers are required to be used with for threaded engagement. A choice of two Model CCP cover Model CCP cover plates.A standard profile Model CCP cover plate assemblies provides either 1/2-inch (13mm) or 5/8-inch plate is available that provides up to 1/2-inch(12.7mm)of cover (8mm) of cover adjustment. Do not install Model F1 FR Series plate adjustment. In addition, a low profile Model CCP cover Concealed Pendent sprinklers in ceilings which have positive plate is also available that provides up to 5/16-inch (8.0mm)of pressure in the space above. cover plate adjustment. See the Design and Installation Infor- Model F1 FR Series Concealed Pendent sprinklers require mation and Listed and Approved Temperature Ratings tables a 2-5/8-inch (67mm) diameter hole to be cut in the ceiling. The in this Bulletin for further information on approved cover plate Model W4 wrench is used to engage the sprinkler wrenching sur- options. faces and to install the sprinkler in the fitting.Remove the protective Application cap to install the sprinkler,then reinstall the protective cap until the Model F1 FR Series sprinklers are intended for use in ac- cover plate is installed.When inserting or removing the wrench from cordance with NFPA 13, FM Property Loss Prevention Data the sprinkler/cup assembly, care should be taken to prevent dam- Sheets, and the requirements of the Authority Having Juris- age to the sprinkler. Do not wrench any other part of the sprinkler/ diction. Care must be exercised that the k-factor, tempera- cup assembly. Installation is completed by removing the protective ture rating, deflector style, and sprinkler type are in accor- cap from the sprinkler and pushing the cover plate onto the cup. dance with the requirements of the applicable design and Final adjustment is made by hand turning the cover plate until the installation standards. In addition, Model F1 FR Series sprin- skirt flange makes full contact with the ceiling.Cover plate removal klers must be used in accordance with their listings and ap- requires turning the cover plate in the counter clockwise direction. provals, as well as the information provided in this Bulletin. After installation, inspect all sprinklers to ensure that there is a gap Installation between the cover plate and ceiling and that the four cup slots are Glass bulb sprinklers have orange bulb protectors or protec- open and free from any air flow impediment to the space above. tive caps to minimize bulb damage during shipping, handling Concealed cover plate/cup assemblies are listed only for use and installation. Reliable sprinkler installation wrenches are with specific sprinklers.The use of any concealed cover plate/ designed to install sprinklers with bulb protectors in place. Re- cup assembly other than the Reliable Model CCP with Model move the bulb protector at the time when the sprinkler system is F1 FR56 Concealed Pendent and Model F1 FR56LL Concealed placed in service for fire protection.Removal of the bulb protec- Pendent sprinklers or the use of the Model CCP Concealed tor before this time may leave the bulb vulnerable to damage. cover plate assembly on any sprinkler with which it is not spe- Remove bulb protectors by undoing the clasp by hand. Do not cifically listed my prevent good fire protection and will void all use tools to remove bulb protectors. guarantees,warranties,listings and approvals. 2. r , Technical Data: Sensitivity: Quick-response Thread Size: 1/2-inch NPT standard; ISO 7-R1/2 optional Maximum Working Pressure: 175 psi (12 bar) - 100% Factory tested hydrostatically to 500 psi (34.5 bar) SIN RA1425, RA1414 & RA1435 cULus listed for 250 psi (17 bar) Design and Installation Information Nominal Nominal Nominal K-factor Orifice Deflector/ Sprinkler Installation Listings Approval Model Diameter Orientation Height Wrench SIN and Notes Approvals US Metric inches mm inches mm Pendent 2.25 57 W2 RA1411 cULus 2 F1FR28 2.8 40 3/8 10 Recessed Pendent 2.25 57 W4 RA1411 cULus 2 Upright 2.25 57 W2 RA1421 cULus 1,2 F1 FR40 4.0 57 3/8 10 Pendent 2.25 57 W2 RA1418 VdS Recessed Pendent 2.25 57 W4 RA1418 VdS Pendent 2.25 57 W2 RA1413 cULus 2 F1FR42 4.2 60 7/16 10 Recessed Pendent 2.25 57 W4 RA1413 cULus 2 Upright 2.25 57 W2 RA1423 cULus 1,2 F1FR42LL 4.2 60 7/16 10 Pendent 2.25 57 W2 RA1410 cULus, ULH Recessed Pendent 2.25 57 W4 RA1410 cULus,ULH F1FRXLH Pendent 2.25 57 W2 RA1413 cULus 2 (F1FR42 4.2 60 7/16 10 Recessed Pendent 2.25 57 W4 RA1413 cULus 2 with Pintle) Upright 2.25 57 W2 RA1423 cULus 1,2 cULus, FM, Pendent 2.25 57 W2 RA1414 LPCB,VdS, EC, 1,2,3,4 • cULus, FM, Recessed Pendent 2.25 57 W4 RA1414 LPCB,VdS, EC, 1,2,3,4 WM F1FR56 5.6 80 1/2 15 on ea d • n.-nt '•1. 4 WM cULus,FM, Upright 2.25 57 W2 RA1425 LPCB,VdS, EC, 1,2,3,4 WM "Conventional 2.25 57 W2 RA1475 LPCB,VdS,EC, 4 (Pendent or Upright)" WM Pendent 2.25 57 W2 RA1415 cULus, ULH 1 F1 FR56LL 5.6 80 1/2 15 Recessed Pendent 2.25 57 W4 RA1415 cULus,ULH Concealed Pendent 2.25 57 W4 RA1415 cULus,ULH 6 Horizontal Sidewall 2.63 67 W2 RA1435 cULus, FM 1,2,3,7 F1FR56 5.6 80 1/2 15 Recessed Horizontal 2.63 67 W4 RA1435 cULus, FM 8 Sidewall F1FR56 5.6 80 1/2 15 Vertical Sidewall(Pen- 2 25 57 W2 RA1485 cULus,FM, 1,2,3,9 dent or Upright) LPCB (1)cULus Listed Corrosion Resistant sprinkler when ordered with available Polyester coating. (2)cULus Listed Corrosion Resistant sprinkler when ordered with available Electroless Nickel PTFE plating. (3)Available with FM approved Polyester coating in black or white. (4)Available with LPCB and VdS approved Polyester coating. (5)VdS and EC approvals of the F1FR56 Concealed Pendent sprinkler are for 155°F(68°C)temperature rated sprinklers only.VdS approved sprinklers must use Norbulb brand glass bulbs with the 1/2-inch(12.7mm)adjustment Model CCP cover plate only. (6)Model F1FR56 Concealed Pendent and Model F1 FR56LL Concealed Pendent sprinklers must be used with Reliable Model CCP cover plates,available as either standard depth with 1/2-inch(12.7mm)of adjustment or low profile with 5/16-inch(8.0 mm)of adjustment. (7)cULus Listing of the F1FR56 Horizontal Sidewall sprinkler is for Light and Ordinary Hazard occupancies only. Minimum to maximum deflector to ceiling distance shall be 4 inches to 12 inches(102mm to 305mm).FM Approval of the F1FR56 Horizontal Sidewall sprinkler is for Light Hazard occupancies only. (8)cULus Listing and FM Approval of the F1FR56 Recessed Horizontal Sidewall sprinkler is for Light Hazard occupancies only. (9)The F1FR56 Vertical Sidewall sprinkler is listed and approved for use only in Light Hazard occupancies.LPCB approval of the F1FR56 Vertical Sidewall sprinkler is for installation in the Pendent position only. 3. . t Listed and Approved Temperature Ratings Ordinary Temp. Intermediate Temp. High Temp. Classification Classification Classification Deflector/ 100°F(38°C)Max.Ambient 150°F(65°C)Max.Ambient 225°F(107°C)Max. Model Orientation Temp. Temp. Ambient Temp. 135°F(57°C) 155°F(68°C) 175°F(79°C) 200°F(93°C) 286°F(141°C)Temp. Temp.Rating Temp. Rating Temp.Rating Temp. Rating Rating Orange Bulb Red Bulb Yellow Bulb Green Bulb Blue Bulb Pendent cULus F1FR28 Recessed Pendent cULus Upright cULus F1 FR40 Pendent VdS Recessed Pendent VdS Pendent cULus F1FR42 Recessed Pendent cULus Upright cULus Pendent ,`. �,� _` l (? cULus,ULH F1 FR42LL " €� °� `Y;sr ��,�t Recessed Pendent cULus,ULH Pendent cULus F1 FRXLH Recessed Pendent cULus Upright cULus Pendent cULus,FM, LPCB,VdS, EC,WM Recessed Pendent cULus, FM, LPCB,VdS,EC,WM F1FR56 41 Concealed Pendent* cULus,WM cULuNVMS,EC, cULus,WM Upright cULus,FM, LPCB,VdS, EC,WM "Conventional LPCB,VdS,EC,WM (Pendent or Upright)" Pendent , WU ur)' ,a., ;Lti s, i"tut t i( d 1`°r: cULus, ULH , =� . F1FR56LL Recessed Pendent t ap 0,1 i t� �' . cULus,ULH Concealed Pendent* 'fit,,,4r ;t a.,`,�; ,, ,� tfi' 1. xa� � cULus, ULH Horizontal Sidewall cULus, FM F1FR56 Recessed Horizontal cULus, FM Sidewall F1FR56 Vertical Sidewall(Pen cULus, FM, LPCB dent or Upright) * Model F1FR56 Concealed Pendent and F1FR56LL Concealed Pendent sprinklers must be used with Reliable Model CCP cover plates. For Ordinary Temperature Classification sprinklers use a 135°F (57°C) temperature rated cover plate. For In- termediate Temperature Classification sprinklers use a 165°F (74°C) temperature rated cover plate. Recessed Escutcheon Data Listed and Approved Recessed Escutcheons Deflector/ Model F1 Model F2 Model FP Model Orientation (Fig.1 &3) (Fig. 1 &3) (Fig.2) SIN 3/4-inch(19mm) 1/2-inch(12.7mm) 1/2-inch(12.7mm) adjustment adjustment adjustment F1FR28 Recessed Pendent _ cULus cULus cULus RA1411 F1FR40 Recessed Pendent VdS VdS VdS RA1418 F1FR42 Recessed Pendent cULus cULus cULus RA1413 F1FR42LL Recessed Pendent cULus, ULH cULus, ULH cULus,ULH RA1410 F1 FR42XLH Recessed Pendent cULus cULus cULus RA1413 F1FR56 Recessed Pendent cULus, LPCB,VdS, cULus, FM, LPCB, cULus,VdS,EC,WM RA1414 EC,WM VdS, EC,WM F1FR56LL Recessed Pendent cULus, ULH cULus, ULH cULus,ULH RA1415 F1FR56 Recessed Horizontal Sidewall cULus cULus, FM cULus RA1435 4. T 2 1/4"HOLE D/A. J [57.2mm] 1 15/16"D(A [49.2mm] / L1-_______—__-1 1" X 1/2" REDUCER TURN COLLAR UNTIL TIGHT AGAINST SPRINKLER I WRENCH BOSS \ FACE OF FITTING \ l / 1 TO FACE OF CEILING DIMENSION F1 I 1 ESCUTCHEON / ) - ( I fl 11 AT MAXIMUM RECESS = 1[25.4mm] ��� \� L _I � AT MINIMUM RECESS = 3/8'(9.Smm] Fl ESCUTCHEON /Ac2M? UTMCHREEOcNESS = 3/4[19mm] ADJUSTMENT 03StlU / AT MINIMUM RECESS = 3/8'[9.5mm] F2 ESCUTCHEON //�///� 1/2-12.7mm] f o T. ADJUSTMENT Fl ESCUTCHEON 1/8" f AT MAXIMUM RECESS = 7/8[22.2mm] [3.2mm] /AT MINIMUM RECESS = 1-5/8[41.3mm] F2 ESCUTCHEON AT MAXIMUM RECESS = 1-1/8[28.5mm] AT MINIMUM RECESS = 1-5/8[41.3mm] 2 27/32"DIA. [72.2mm] Fig. 1 Model F1 FR56,F1 FR56LL,F1 FR42,F1 FR40,F1 FR42LL,F1 FRXLH&F1 FR28 Recessed Pendent sprinkler with Model F1 or F2 escutcheon I I 1" X 1/2" REDUCER 2 5/8" DIA. (66.7mm] HOLE IN CEILING 1 I 2 5/16" DIA. [58.7mm] CUP L - J CEILING _ FACE OF FITTING —� TO FACE OF CEILING III ®3�V8 I''II DIMENSION III: _ :.III' �i,01 i ���I I j; AT MAXIMUM RECESS = 1-1/2[38mm] _ AT MINIMUM RECESS = 1[25.4mm] �1,\_ �,� AT MAXIMUM RECESS = 9/16[14.3mm] MI s %2'(12.7mm] ��,,,� AT MINIMUM RECESS = 1[25.4mm] ADJUSTMENT .... m...,, 3 1/4" DIA. _ t [82.6mm] Fig.2 Model F1 FR56,F1 FR56LL,F1 FR42,F1 FR40,F1 FR42LL,F1 FRXLH&F1 FR28 Recessed Pendent sprinkler with Model FP escutcheon 5. S L FACE OF FITTING TO FACE OF CEILING DIMENSION Fl ESCUTCHEON 7//// /A AT MAXIMUM RECESS = 1[25.4mm] AT MINIMUM RECESS = 3/8 79.5mm] Fl ESCUTCHEON F2 ESCUTCHEON 1O AT MAXIMUM RECESS = 1-3/8[34.9mm] AT MAXIMUM RECESS = 3/4[19mm] AT MINIMUM RECESS = 2-1/16[52.4mm] AT MINIMUM RECESS = 3/8[9.5mm] f2 ESCUTCHEON AT MAXIMUM RECESS = 1-5/8[41.3mm] 2 1/4" HOLE DIA. i/8" AT MINIMUM RECESS = 2-1/16[52.4mm] [57.2mm] [3.2mm] 1" X 1/2" REDUCER _1.I►I _ .\ ill 1 liiii I . 4"-12" 1 15/16" D/A.`1 iI Lim ���_, fig"*"'—{ — — 'Ni [101.6mm-304.8mm] [49.2mm] I I ,,IVY "d' 2 27/32" DIA. CEILING TO I °" I i� ' [72.2mm] DEFLECTOR i `_nm 46 TURN COLLAR UNTIL TIGHT AGAINST L WRENCH BOSS.SPRINKLER Fl ESCUTCHEON 3/4[19mm] ADJUSTMENT —.F.— F2 ESCUTCHEON 1/2[12.7mm] ADJUSTMENT 01,VOWE RECESSED HSW W/F1 OR F2 ESCUTCHEON (1) FM APPROVED FOR 4" — 6" [101.6MM — 152.4MM] CEILING TO DEFLECTOR WITH F2 ONLY. Fig.3 Model F1 FR56 Recessed Horizontal Sidewall sprinkler with Model F1 or F2 escutcheon 1" x 1/2" REDUCING TEE OR ELBOW — J __ 2 5/8" DIA. 2 5/16" DIA — ;� HOLE IN CEILING CUP —,�= �� 111111 11� 1I 1 1/2" MAX. `////1/// 110 Il IRji FACE OF FITTING r _TO FACE OF CEILING ice= _ •„ ,■ riiiiiiii DIMENSION CEILING ,�\ •■Slinitp%� iiiiiiiJ i 1/2" MAX. 1' COVER ADJUSTMENT COVER PLATE ASSEMBLY /3 5/16" DIA. � SPRINKLER / CONCEALED, 1/2" ADJUSTMENT 017FGO1A Fig.4 Model F1 FR56/F1 FR56LL Concealed Pendent sprinkler with standard depth 1/2-inch(12.7mm)adjustment-Model CCP cover plate 6. I I 1" x 1/2" REDUCING TEE OR ELBOW [.H —+I - -- -+— µ}"- - -it --_---1--"'"-_ 2 5/8" D/A. 2 5/16" 0/A — HOLE IN CEILING L' l q J _ r ���� o �� 1 1/2�' MAX. CUP t: FACE OF FITTING """"� �° °1 TO FACE OF CEILING ,,,'I !/t0 � �: DIMENSION CEILING -- — 5/16" MAX. 3/4" COVER ADJUSTMENT COVER PLATE / I t — ASSEMBLY - 3 5/16" D/A. . - SPRINKLER CONCEALED, 5/16" ADJUSTMENT 017FG02A Fig. 5-Model F1 FR56/F1 FR56LL Concealed Pendent sprinkler with low profile 5/16- inch (8.0mm) adjustment- Model CCP cover plate Maintenance Material Data The Model F1 FR Series sprinklers should be inspected and Frame: DZR Brass,QM Brass,or Low Lead Brass the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any Deflector: CDA Alloy 220,260,or 510 other cleaning fluids.Remove dust by using a soft brush or gen- Load Screw\Pintle: CDA Alloy 360 or 544 tle vacuuming. Replace any sprinkler which has been painted Cup: CDA Alloy 651 or 693 (other than factory applied) or damaged in any way.A stock of Washer: Nickel Alloy 440 or 360,coated with PTFE spare sprinklers should be maintained to allow quick replace- Adhesive Tape ment of damaged or operated sprinklers. Bulb: Glass Finishes (1) Standard Finishes Sprinkler Escutcheon Cover plater') Ordering Information Bronze Brass Chrome Specify: Chrome Plated Chrome Plated I White 1. Sprinkler Model: [F1 FR28][F1 FR40][F1 FR42] Polyester Coated(4)( ) White Painted Special Application Finishes [F1 FR42LL][F1 FRXLH][F1 FR56][F1 FR56LL] Sprinkler Escutcheon Cover plater') 2. Sprinkler Deflector/Orientation: [Pendent][Recessed Electroless Nickel Electroless Nickel Pendent][Upright][Conventional][Horizontal Sidewall] PTFE PTFE Bright Brass [Recessed Horizontal Sidewall][Vertical Sidewall] Bright Brasst3) Bright Brass Black Plating Black Plated Black Plated Black Paint 3. Sprinkler threads: [1/2-inch NPT][ISO 7-R1/2] Black Paint(2)(6) Black Paint Off White 4. Sprinkler Temperature Rating: [135°F (57°C)][155°F Off Whitet21(6) Off White Satin Chrome (68°C)][175°F (79°C)][200°F (93°C)][286°F (141°C)] Chrome Dull Chrome Dull 5. Sprinkler Finish 11)Other finishes and colors are available on special order.Consult the fac- tory for details. Custom color painted sprinklers may not retain their UL 6. Escutcheon Model: [F1][F2][FP] Corrosion resistance listing.Coverplate custom paint is semi-gloss,unless 7. Escutcheon Finish (where applicable) specified otherwise. 8. Cover plate Model: [standard profile CCP 1/2-inch (2) cULus Listed only. (12.7mm) adjustment][low profile CCP 5/16-inch (3) 200°F(93°C)maximum. (4) cULus listed "corrosion resistance" applies to SIN Numbers RA1435 (8.0mm) adjustment] (HSW),RA1485(VSW),RA1425(Upright),RA1414(Pendent)and RA1415 9. Cover plate Temperature Rating: [135°F (57°C) for use (Pendent)in standard black or white.Corrosion resistance in other polyester with Ordinary Temperature sprinklers][165°F (74°C) for colors is available upon request. use with Intermediate Temperature sprinklers] (5) FM Approvals finish as"Polyester coated"applies to SIN Number RA1414,RA1435 and RA1425 in standard black or white. 10. Cover plate Finish (6)LPCB and VdS Approved finish applies only to RA1425,RA1414,RA1418 (VdS) and RA1475. Note:When Model F1 FR Series Recessed sprinklers are ordered,the sprin- (7)cULus listed Corrosion Resistant klers and escutcheons are packaged separately. 7. Reliable . . . For Complete Protection Reliable offers a wide selection of sprinkler components. Following are some of the many pre- cision-made Reliable products that guard life and property from fire around the clock. • Automatic sprinklers • Deluge valves • Flush automatic sprinklers • Detector check valves • Recessed automatic sprinklers • Check valves • Concealed automatic sprinklers • Electrical system • Adjustable automatic sprinklers • Sprinkler emergency cabinets • Dry automatic sprinklers • Sprinkler wrenches • Intermediate level sprinklers • Sprinkler escutcheons and guards • Open sprinklers • Inspectors test connections • Spray nozzles • Sight drains • Alarm valves • Ball drips and drum drips • Retarding chambers • Control valve seals • Dry pipe valves • Air maintenance devices • Accelerators for dry pipe valves • Air compressors • Mechanical sprinkler alarms • Pressure gauges • Electrical sprinkler alarm switches • Identification signs • Water flow detectors • Fire department connection The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association,Factory Mutual Research Corporation,or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 100 years. Manufactured by Reliable Automatic Sprinkler Co.,Inc. ® Recycled ® (800)431 1588 Sales Offices Paper Reliabi (800)848 6051 Sales Fax Revision lines indicate updated or new data. (914)829 2042 Corporate Offices www.reliablesprinkler.com Internet Address EG.Printed in U.S.A.08/21 P/N 9999970300 Victaulic® VicFlexTM Sprinkler Fittings 4tui,cr Series AH2 and AH2-CC Braided Flexible Hoses 1o.85 Vic Flex" 141 Series AH2 Series AH2-CC 1.0 PRODUCT DESCRIPTION Available Sizes by Component Series AH2 1"IDN25 ID Braided Hose:31, 36,48, 60, 72"/790, 915, 1220, 1525, 1830 mm. Note: length includes adapter nipple and 5.757140 mm straight reducer. Series AH2-CC 1"/DN25 ID Braided Hose: 31, 36, 48, 60, 727790, 915, 1220, 1525, 1830 mm. Note: length includes captured coupling and 5.75"/140 mm straight reducer. Connections • From Branchline • 3/4"/2Omm BSPT female thread (VdS only) • 1 1/4"/32mm BSPT female thread (LPCB only) • 1"/25mm NPT or BSPT female Thread • 1"/25mm Grooved IGS(refer to Submittal 10.54 for additional IGS connections) • No. 116 CPVC Adapter (1"/25mm Female CPVC Socket x 1"/25mm Grooved IGS) • No. 142 Welded Outlet • Style 922 Outlet-T • Style 92ON Mechanical-T Outlet • No. 65 Grooved End of Run Fitting • Hose Inlet • 1"/25mm Grooved IGS • 1"/25mm NPT or BSPT male thread • 3/4"/2Omm BSPT male thread (VdS only) • 1 1/4"/32mm BSPT male thread (LPCB only) ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION,MAINTENANCE OR SUPPORT. System No. Location Spec Section Paragraph Submitted By i Date Approved Date victaulic.com 10.85 5839 Rev AK Updated 03/2021 ©2021 Victaulic Company.All rights reserved. 1 scts:w hog k victaulic.com 1.0 PRODUCT DESCRIPTION (CONTINUED) • Sprinkler Reducer • Sprinkler Connection: 1" and 3/4"/15mm and 20mm NPT or BSPT female thread • Straight Lengths: 5.75", 9", 13"/140mm, 230mm, 330mm • 90° Elbows • Standard Short • Low Profile Short • Standard Long • Low Profile Long (Short elbows typically used with concealed sprinklers. Long elbows typically used with recessed pendent sprinklers) Brackets • Style AB2 for suspended and hard-lid ceilings and sidewalls, allows for vertical sprinkler adjustment, and installation before most ceiling tiles in place • Style AB3 for surface mount applications, wood, metal and block walls, or ceilings • Style AB4 for hard-lid ceilings with hat furring channel grid systems, allows for vertical sprinkler adjustment • Style AB5 for hard-lid ceilings and sidewalls, allows for vertical sprinkler adjustment • Style AB7 for suspended and hard-lid ceilings • Style AB7 Adjustable for suspended and hard-lid ceilings • Style AB10 for Armstrong®TechZone'° ceilings • Style AB11 for lay-in panel suspended t-grid ceilings or drywall suspended t-grid ceilings, allows for low profile installations (use only with 90° low profile elbows) • Style AB12 for suspended and hard-lid ceilings, allows for vertical sprinkler adjustment, and allows for low profile installation down to 4'7100mm. • Style ABBA bracket for suspended, exposed, and hard-lid ceilings • Style ABMM bracket for surface mount and stand off-mount applications, wood, metal and block walls, or ceilings and hard-lid ceilings • Strut channel and pipe clamp, not supplied by Victaulic Maximum Working Temperature • 225°F/107°C • 150°F/65°C (No. 116 CPVC Adapter) Maximum Working Pressure • 200 psi/1375 kPa (FM Approval) • 175 psi/1206 kPa (cULus Listed) • 1600 kPa/232 psi (VdS/LPCB Approved) • 1.4 MPa (CCCf Approved) • 175 psi/1206 kPa (No. 116 CPVC Adapter) Minimum Bend Radius • 7"/178mm (FM/CCCf Approval) • 2'/51 mm (cULus Listed) • 3"/76.2 mm (VdS/LPCB Approved) 10.85 5839 Rev AK Updated 03/2021 ©2021 Victaulic Company.All rights reserved. victaulic.com 2 jctaulic' r , victaulic.com 1.0 PRODUCT DESCRIPTION (CONTINUED) • Maximum Allowable Sprinkler K-Factors • FM (1/2715 mm reducer) K5.6/8,1 (S.I.), (3/4720 mm reducer) K14.0/20,2 (S.I.) • cULus (1/2715mm reducer) K8.0/11,5 (S.I.), (4720mm reducer) K14.0/20,2 (S.I.) • VdS/LPCB (1/2715mm reducer) K5.6/8,1 (S.I.), (3/4720mm reducer) K8.0/11,5 (S.I.) 2.0 CERTIFICATION/LISTINGS ® cOus VdS LPCB LISTED NOTE • The VicFlex Series AH2 Hose has been tested and evaluated by Spears®for acceptable use with Spears®CPVC Products and is therefore covered under the Spears®FlameGuard®Installer Protection Plan. 3.0 SPECIFICATIONS — MATERIAL Series AH2: Flexible Hose: 300-series Stainless Steel Collar/Weld Fitting: 300-series Stainless Steel Gasket Seal: Victaulic EPDM Isolation Ring: Nylon Nut and Nipple: Carbon Steel, Zinc-Plated Reducer (112"/15 mm or 3/4"/20 mm): Carbon Steel, Zinc-Plated Low Profile Elbows: Ductile Iron, Zinc-Plated Brackets: Carbon Steel, Zinc-Plated Series AH2-CC: Flexible Hose: 300-series Stainless Steel Collar/Weld Fitting: 300-series Stainless Steel Gasket Seal: Victaulic EPDM Isolation Ring: Nylon Coupling Retainer Ring: Polyethelene Nut: Carbon Steel, Zinc-Plated Reducer (1/"/15 mm or 3/4'"/20 mm): Carbon Steel, Zinc-Plated Low Profile Elbows: Ductile Iron, Zinc-Plated Housing: Ductile iron conforming to ASTM A 536, Grade 65-45-12. Ductile iron conforming to ASTM A 395, Grade 65-45-15, is available upon special request. Coupling Housing Coating: • Orange enamel (North America, Asia Pacific). • Red enamel (Europe). • Hot dipped galvanized. Gasket:1 Grade "E" EPDM (Type A) FireLock EZ products have been Listed by Underwriters Laboratories Inc., Underwriters Laboratories of Canada Limited, and Approved by Factory Mutual Research for wet and dry (oil free air) sprinkler services within the rated working pressure. 1 Services listed are General Service Guidelines only.It should be noted that there are services for which these gaskets are not compatible.Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service guidelines and for a listing of services which are not compatible. Bolts/Nut: Zinc electroplated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A 449 and physical requirements of ASTM A 183. Linkage: CrMo Alloy Steel zinc electroplated per ASTM B633 Zn/Fe 5, Type III Finish No. 116 Adapter Fitting: CPVC and Brass Seal:Victaulic EPDM 10.85 5839 Rev AK Updated 03/2021 ©2021 Victaulic Company.All rights reserved. victaulic.com 3 ✓ctaulacr victaulic.com • •4.0 DIMENSIONS Product Details- Series AH2 Braided Hose Item I Description O 1 Flexible Hose " Y� Q 0 O O 0 p 2 Isolation Ring y IG 3 Gasket ;z tld ' Ly,—t_kl_ I�'! ��"i�� 4 Nut 5 Adapter Nipple , ,,l., „ a 4- A >.I 6 Braid ` — B 7 Collar/Weld Fitting 8 Sleeve 9 Reducer Hose Length Dimensions Hose Length A B inches inches inches mm mm mm 31 25.3 31 790 641 790 36 31.3 36 915 794 915 48 42.3 48 1219 1073 1220 60 54.3 60 1525 1378 1525 j 72 66.3 72 f. 1830 1683 1830 .:.z Series AH2-CC Braided Hose Item I Description O 1 i Flexible Hose ¢ 2 Isolation Ring O 00 b O O 0 co I Gasket 4 Nut ()iiNirk i I �j o �� _ 5 I Captured Couplin• ,111 �I I�IB1!lhl�S1/rIYB�il 6 Braid 7 Collar/Weld Fittin•r= A 8 I Sleeve B , ( 9 i Reducer ......,. - Hose Length A B inches inches inches mm mm mm 31 24.5 29.8 790 1 622 757 36 29.5 34.8 915 749 884 I 48 41.5 46.8 1219 1054 1189 60 53.5 58.8 1525 1359 1494 72 65.5 70.8 1830 1664 1798 10.85 5839 Rev AK Updated 03/2021 0 2021 Victaulic Company.All rights reserved. victaulic.com 4 jctsaulicr 'il+..:tritlt1<.. .:Xti •4.0 DIMENSIONS (CONTINUED) Standard Reducer illllllnlllllllllllllllllllll L 'i llillitillilllillllllllll, In 5.757140 mm straight reducer Optional Reducers 2.62"/ 66.5 mm l.— 2.62"/ . % I' 111 66.5 mm r A I' 1 725"/ 184.2 mm II 1111 I L IIIIIII 1 )— 9.7m — — 6.9m 5=- : _ ■nlnll ■I fff 139.7 mm 166.9 mm _ 500"/ — - 127.0 mm 9.0"/229 mm straight reducer 4.83"/ = Ill = 3.25"/ 122.7 mm E I 82.6 mm = - IIIM N 1 ■■ • 13.0"/330 mm straight reducer Short 90°elbow reducer Long 90°elbow reducer NOTE • The Short 90°elbow reducer is typically used with concealed sprinklers while the longer 90 elbow is typically used in the installation of recessed pendent sprinklers. • FM/VdS Approved only. Low Profile dl' _ __ 4.59/dii 3.50"/ 3.63"/ = = 116 mm 2.84"/ 89 mm 92 mm 1.88"/ = 72 mm = _ 48 mm = = _ _ 1.4'/ 1.4"/ 36mm 36mm Short 90°elbow reducer Long 90°elbow reducer NOTE • Style AB11:When low profiles elbows are with the Style AB11 bracket,the Low Profile Short Elbow is typically used with concealed sprinklers while the Low Profile Long Elbow is typically used in the installation of recessed pendent sprinklers. No. 116 CPVC Adapter E to E liii NOTES • E to E is 3.0"/76.0 mm • The No. 116 CPVC Adapter has 2 ft.(0.6 m)EQL of 1"Schedule 40 pipe. • • 10.85 5839 Rev AK Updated 03/2021 C 2021 Victaulic Company.All rights reserved. U"t:tai lic,' • •4.1 DIMENSIONS VicFlex Brackets Style AB2 • Suspended Ceilings • Hard-Lid Ceilings Item Description 1 24"/610 mm or 4871219 mm Square Bar 2 Patented Vertically Adjustable Center Bracket ilk O 3 End Bracket NOTE • Both sizes FM/VdS/LPCB Approved,cULus listed Style AB3 _- � • Surface Mount Applications /�=\ • FM/LPCB Approved rtio 1111. � e Style AB4 • Hard-Lid Ceilings with Hat furring ` o channel grid system i� Item Description 1 24"/610mm or48"/1219mm Square Bar 2 Patented Vertically Adjustable Center Bracket 3 ( End Bracket for Hat Furring Channel ,,_1e NOTE • Both sizes FM/VdS/LPCB Approved,cULus listed. vl'; • • 10.85 5839 Rev AK Updated 03/2021 ©2021 Victaulic Company.All rights reserved. e victaulic.com • • 4.2 DIMENSIONS VicFlex Brackets Style AB5 • Hard-Lid Ceilings ", �I Item Description 1 24"/610mm or 48"/1219 mm Square Bar 2 Patented Vertically Adjustable Center Bracket �*r` 3 End Bracket 2, O NOTE • Both sizes FM/VdS/LPCB Approved,cULus listed. Style AB7 • Suspended Ceilings • Hard-Lid Ceilings .-T- Item Description 1 247610 mm or 48"/1219 mm Square Bar 2 Patented 1ter BracketNOTE• sizes FM/VdS/LPCB pproved. •hii, Style AB7 Adjustable ,01 • Suspended Ceilings111 • Hard-Lid Ceilings r Item Description 4* 0 1 700mm or 1400mm Square Bar 2 i Patented 1-Bee2•Center Bracket 3 End Bracket(adjustable) 4+r NOTE J�� O • Both sizes FM/VdS/LPCB Approved. 1.1/ • • • 10.85 5839 Rev AK Updated 03/2021 ©2021 Victaulic Company.All rights reserved. V1C;`trif.l'sl{. curl 4.3 DIMENSIONS VicFlex Brackets Style AB10 • Suspended ceilings • Armstrong®TechZone'M '( © O Item Description 1 6"/152 mm Square Bar 2 Patented 1-Beer Center Bracket 3 End Bracket NOTE • FM/VdS/LPCB Approved,cULus listed. Style AB11 • Suspended ceilings • Hard-Lid ceilings Item Description 1 24"/610 mm or 48"/1219 mm Square Bar O 2 Patented 1-Beer Center Bracket 3 End Bracket NOTE • FM/VdS Approved,cULus listed. Style AB12 • Suspended ceilings • Hard-Lid ceilings Item Description , 1 Style A612 Bracket Body I;/ 0 2 #2 Square Drive Set Screw / NOTE • FM/VdS Approved • • 10.85 5839 Rev AK Updated 03/2021 ®2021 Victaulic Company.All rights reserved. T � t•!a %catila,...0`,1 • • 4.3 DIMENSIONS (CONTINUED) VicRex Brackets Style ABBA • • Floor-above mount • • Cantilever mount • Temporary mount in exposed ceilings Item Description 1 Style ABBA Mounting Plate 2 Style ABBA Square Bar 3 Cap Screw,Serated Flange,M6 x 1 x 20, T25 Torx Drive Recessed 4 Style ABMM Bracket Body 0 (IA Cap Screw,Serated Flange,M6 x 1 x 15.24, 4�- �- 5 T25 Torx Drive Recessed NOTE • FM Approved. Style 'qt. %, • Surface mount 4 • Stand-off mount 10 _ -4 (? ��� Item Description 1 Style ABMM Bracket Body V.P' 2 Cap Screw,Serated Flange,M6 x 1 x 15.24, T25 Torx Drive Recessed NOTE • FM Approved. • • 10.85 5839 Rev AK Updated 03/2021 ©2021 Victaulic Company.All rights reserved. victaulic.com • • 4.4 DIMENSIONS Clearances Series AH2 Braided Hose and Style AB2 Bracket 1 R See Table L Bracket Assembly {{{{ , . ))}) Style A62 lob I — I 1.1 I ® i ■— I m 23)(3760.33 mm 111 mm \I =2=_ i% 2"/50.80mm (I __ 5/8"/15.9 mm \ / Typical II ��iii�\ ceiling tile Ili*I =/ 1.7"/43 mm i —`J Typical ceiling grid' ice- h a Finished r'1 surface I, See note 24"/610 mm or 48"/1219 mm on Center V2707 3/4"/19 MM MAX.RECESS V2707 MAX.EXTENSION Hose Clearance Chart Straight Reducer i Long Elbow Short Elbow V2707 V3802 V2707 1 V3802 3A" 1h" 3/a" 1" V2707 V3802 V2707 V3802 Max Recess Max Recess Max Recess Max Recess 3/4'Max Recess '/i'Max Recess 3/4•Max Recess 1/2"Max Recess inches inches inches inches inches inches inches inches mm mm mm mm mm mm mm mm "R"Minimum 2.0 3.0 7.0 _ Bend Radius 50 80 175 "A"Minimum Required 8.6 10.1 9.6 i 11.1 13.6 i 15.1 5.8 5.8 Installation 218 269 244 ' 281 345 383 147 147 Space f_ NOTE • Variations of ceiling grids,sprinkler heads,brackets,and hoses are permitted but may result in clearance differences from the figures above. • 10.85 5839 Rev AK Updated 03/2021 ©2021 Victaulic Company.All rights reserved. r i ,'.rLiii",1tlz..:..O11'. • • 4.5 DIMENSIONS Clearances Series Al-12 Braided Hose and Style AB2 Bracket #1 Ell See chart =M A SWAM See Chart r7 Bracket f Assembly #10 Screw Style AB21M1/ 21t /68 mm _- In1 1.8"/45 mm max.hole ♦ :.nIr F — — _ Ill min.hole 2"x 4" :l�l , , ��� Ili>I:i:i: " _ -1 i�;. >_ Stud i �I { T �� { fi T fi 3vz"/ _ I I ¢9 I I % 89 mm ...•••••••• Il I I i�`�;� I _III I 1 © __ - r_V_1--- I I I _ �: I I —��.A.�`= I I I ..... I ��r�it Finished 5/s"/16 mmj Typical 16"/406 mm C/C ceiling Typical drywall V38'"/13 mm MAX.RECESS V38 MAX.EXTENSION Hose e Clearance Chart Straight Reducer V2707 V3802 I V2709 V2707 V3802 V2709 V2707 V3802 V2709 3 "I20mm 1/2"I13mm 3/4'120mm 14"I20mm ' "113mm Vs"I20mm 3/4'I20mm 1/2"I13mm 3/4"I20mm ,Max Recess" Max Recess ; Sidewall I Max Recess Max Recess Sidewall Max Recess Max Recess Sidewall inches inches inches inches inches inches inches inches inches mm mm mm mm mm mm mm mm mm "R"Minimum 2.0 3.0 7.0 Bend Radius 50 80 175 "A"Minimum Required 6.2 7.6 6.1 7.2 8.6 7.1 11.2 12.6 11.1 Installation 158 193 155 183 1 218 180 285 320 282 Space Hose Clearance Chart Long Elbow Short Elbow V2707 V2709 , V3802 3/4"1 20mm 3/4"120mm 1/2"113mm Max Recess Sidewall Max Recess inches inches inches mm mm mm "R"Minimum _ Bend Radius "A"Minimum Required 3.3 i 3.6 1 3.3 Installation . 84 91 i 84 Space i I 1 NOTE • Variations of ceiling grids,sprinkler heads,brackets,and hoses are permitted but may result in clearance differences from the figures above. • • 10.85 5839 Rev AK Updated 03/2021 0 2021 Victaulic Company.All rights reserved. 'rd. e A victaulic.com • •4.6 DIMENSIONS Clearances Series AH2 Braided Hose and Style AB4 Bracket 011 :: R See chart 1- SAWS A ViiiMr See Chart Bracket assembly Style AB4 Typical Hat = _— 4.1"/ 2�/a"/60 mm yP 1 i iiiiii _ i 1 104 mm max.hole Channel 1 i #10 Screw grid 1 1 I I 2"/51 mm _ If min.hole i i ua�E 1 1 /e"/23 mm a V .11I Finished .c_� ceiling Vs"/16 mm _ �'� Typical 16"/406 mm UC Typical drywall V V273/4"/19 mm MAX.RECESS V27 MAX.EXTENSION Hose Clearance Chart Straight Reducer i Long Elbow Short Elbow V2707 V3802 V2707 I V3802 — _ 3/4' ' ye1/.. � � V2707 V3802 V2707 V3802 Max Recess Max Recess , Max Recess Max Recess 3/4"Max Recess 1/2"Max Recess 3/4"Max Recess 1/2"Max Recess inches inches inches inches inches inches inches inches mm mm mm mm mm mm mm mm • "R"Minimum 2.0 2.0 3.0 3.0 7.0 7.0 Bend Radius 50 50 80 80 175 175 "A"Minimum Required 8.8 I 10.2 9.8 11.2 13.8 15.2 8.0 5.9 Installation 224 259 249 285 351 I 386 I 203 150 Space NOTE Variations of ceiling grids,sprinkler heads,brackets,and hoses are permitted but may result in clearance differences from the figures above. • • • 10.85 5839 Rev AK Updated 03/2021 0 2021 Victaulic Company.All rights reserved. #41111MINIIII b.. I I ui{;tafllli,row • • 4.7 DIMENSIONS Clearances Series AH2 Braided Hose and Style AB5 Bracket 4111 R ■■ See chart A See chart SIMI 91.1I rim Bracket ,1�1, assembly _R= __ Style ABS ' 57 mm i i — ;T, _ __ ii — i 2W/60 mm 2"x 4" I : I = I max.hole metal stud 1 ' - i Sys/ 2"/51 mm n' 'l 92 mm min.hole II I ii`A I I i -- i idi u_ i I i tl'iar'it A fA '////// . '%/.Ilir a1 %//%/// ///////% %//.1 �ow" �N� II Finished 5/8"/16 mm �� ceiling Typ.Drywall Typical16"/406 mm C/C a V27 3/4'/19 mm MAX.RECESS V27 MAX.EXTENSION Hose Clearance Chart Straight Reducer _ "V2707 V3802 V2709 V2707 V3802 V2709 V2707 V3802 V2709 3/4'I20mm 1/"I13mm 3/4"I20mm 3/4"I20mm ' "I13mm 3/4"I20mm 3/4"I20mm 1/2"I13mm 3/4'I20mm Max Recess" Max Recess Sidewall Max Recess Max Recess Sidewall Max Recess Max Recess Sidewall inches inches inches inches inches inches inches inches inches mm mm mm mm mm mm mm mm mm "R"Minimum 2.0 3.0 7.0 Bend Radius 50 80 175 "A"Minimum Required 6.0 7.7 6.1 7.0 8.7 7.1 11.0 12.7 11.1 Installation 158 196 155 178 221 180 279 323 282 Space Hose Clearance Chart _...,._.. ...._.._...---- Low-Profile Long Elbow Long Elbow Short Elbow _ V2707 V3802 V2709 i V3802 V3802 3/4"1 20mm l "l 13mm 3/4"120mm 1/2"113mm lh"113mm Max Recess Max Recess Sidewall Max Recess Max Recess inches inches inches inches inches mm mm mm mm mm "R"Minimum _ Bend Radius "A"Minimum Required 3.5 4.9 3.6 2.9 3.3 Installation 89 124 91 74 84 Space NOTE • Variations of ceiling grids,sprinkler heads,brackets,and hoses are permitted but may result in clearance differences from the figures above. • • 10.85 5839 Rev AK Updated 03/2021 0 2021 Victaulic Company.All rights reserved. ait-l.,,l_ili�..E::�:rrl� 4.8 DIMENSIONS • Clearances Series AH2 Braided Hose and Style AB11 Bracket (LOW PROFILE SOLUTION) 23/e760 mm 2116"/68 mm Bracket 7 j max.hole max.hole Assembly ,I�!I" 2"/51 mm 21/e"/60 mm A q p Style AB11 • min.hole min.hole See Chart 0 ' j76rnm LIO ■_ ILL- �� , �' ,; I�i P.�•Li�Ii/� 1, r=11_ 1.7"/43 mm �>jl s i Finished :4� Typical /e"/15.9 mm ceiling face ceiling grid Typical ceiling tile See Note 24"/610 mm or V27 V38 4871219 mm on center Pendent Hose Clearance Chart Low-Profile Low-Profile Long Elbow Short Elbow V2707 ( V3802 3/4"I20mm ' "I13mm Max Recess" Max Recess inches inches mm mm "A"Minimum Required 4.0 3.9 Installation 102 99 Space NOTE • Variations of ceiling grids,sprinkler heads,brackets,and hoses are permitted but may result in clearance differences from the figures above. • • 10.85 5839 Rev AK Updated 03/2021 ©2021 Victaulic Company.All rights reserved. F victaulic.com 4.9 DIMENSIONS Clearances Style AB12 and ABBA Bracket Suspended Ceiling Grid with Recessed Sprinkler with Suspended Ceiling Grid with Recessed Sprinkler and Low Profile Short Elbow Straight 5.757140mm Reducer f. I I Unfinished'i Ceiling Face'':, 1K inch i 29 mm j� • i 1 I I' R Nominal length I 'I` 1P/3556 mm 11 1MUM 21:1- Mil I / alai a rN7 'A' , 11 Unfinished i i -�= See Table _ r---- ffr _ff. E. i Ceiling Facel; _�= 29 mmKinch/ _ _ =Ey=it 11116 '! 3mm 1 I - _ is INI11 1 ,le_ I; K inch -I1�_ I See Table i l "B"See Table 11 3mm I 1 i1.111 $J4:. i 'B'See Table Mini �+4 Finished Face of IW1 ��� Finished Face of ���+++--- a/"-inch/16-mm T *4-indJ16-mm Typical Ceiling Typical Ceiling V2707 W/12.7 mm MAX.RECESS V2707 99"/19 mm MAX.RECESS Low Profile Low Profile Standard Standard Standard Dimension Short Elbow Long Elbow Short Elbow Long Elbow Straight Reducer 3/4719 mm 3/4'719 mm I 3/4719 mm i 3/4'719 mm 3/719 mm" Recessed* Concealed Recessed Concealed' Recessed Concealed Recessed Concealed Recessed Concealed' inches inches inches inches inches inches inches inches inches inches mm mm mm mm mm mm mm mm mm mm A Minimum Required 4.0 5.5 5.6 7.2 5.9 7.5 7.7 9.3 15.0 16.6 Installation Space 101.6 139.7 142.2 182.9 149.9 190.5 195.6 236.2 381.0 421.6 Distance from Top of 0.5 2.0 1.5 1.5 1.5 1.5 3.0 3A 3.0 3.0 B Typical Ceiling Tile to 12.7 50.8 38.1 38.1 38.1 38.1 I 76.2 76.2 76.2 76.2 of Gate L *Adjustability will be limited Style ABMM Bracket Stand-off Dimensions MAIIIIIIIIIIM z.zz"/ _ 56 mm 3.93"/ 2.94"/ rill---T 100 mm © 75 mm 028"/ Q;,it II 100 mm 7mm .!w1-!G�n O ' 10.85 5839 Rev AK Updated 03/2021 ©2021 Victaulic Company.All rights reserved. 4.10 DIMENSIONS • Clearances Style AB3 and ABMM Bracket Surface Mount Application with Recessed Sprinkler A 33/4"/ 95.3mm 41IP' 23/8"/60 mm max.hole 2"/51 mm min.hole Hose Clearances inches inches inches inches inches inches inches inches inches inches Dimension mm mm mm mm mm mm mm mm mm mm Wall Thickness 2 4 6 8 10 2 4 6 8 10 50 100 150 200 250 50 100 150 200 250 Outlet Length 5.75 9 13 5.75 9 13 9 13 13 13 5.75 9 13 5.75 9 13 9 13 13 13 "B" 146.1 228.6 330.2 146.1 228.6 330.2 228.6 330.2 330.2 330.2 146.1 228.6 330.2 146.1 228.6 330.2 228.6 330.2 330.2 330.2 l Hose Clearance f 11.6 1 14.8 1 18.8 1 9.6 112.8 1 16.8 10.8 14.8 1 12.8 10.8 12.6 15.8 19.8 10.6 13.8 17.8 11.8 15.8 13.8 11.8 "C" 294 376 478 243 325 427 275 376 1325 275 319 402 503 268 351 452 300 402 351 300 Bend Radius 7 8 175 200 NOTE • Variations of ceiling grids,sprinkler heads,brackets,and hoses are permitted but may result in clearance differences from the figures above. • • 10.85 5839 Rev AK Updated 03/2021 ®2021 Victaulic Company.All rights reserved. 0. victaulic.corn •4.11 DIMENSIONS BRANCHLINE CLEARANCES Series AH2 Braided Hose with Style 922 threaded outlet Series AH2-CC Braided Hose with Style 922 grooved outlet R See chart �INIMMINIMIMMIIII R See chart ME Ilan A �R A .. See chartIIIIIMIII See chart lill II lit Style 922 Threaded ` . �"- Style 922 �� Mechanical Tee `� — Grooved Outlet W—�_��� Mechanical Tee 1 — . "7.0.1 . Outlet ii ,irl ,....! ti,,.. ),N, . I -0/ \1- 1 isi leg (0,.. %;1• 2750mmNi er '��;. /Im 1 \ it / 2750 mm Hose Clearance Chart Hose Clearance Chart Dimension ' I I I Dimension inches inches inches inches inches inches inches inches inches inches mm mm mm mm mm mm mm mm mm mm Minimum 3 4 5 6 7 Minimum 3 4 5 6 7 R Bend Radius 80 100 125 150 175 R Bend Radius 80 100 125 150 175 A Min. 9.4 10.4 11.4 12.4 13.4 A Min. 7.7 8.7 9.7 10.7 11.7 238 263 289 314 339 197 222 247 273 298 • • 10.85 5839 Rev AK Updated 03/2021 0 2021 Victaulic Company.All rights reserved. victaulic.com 4.12 DIMENSIONS BRANCHLINE CLEARANCES Series AH2 Braided Hose with female threaded outlet Series AH2-CC Braided Hose with grooved outlet R See chart R __ See chart .. See chart See chart 1 ii t !1 ��__�JI 11111 Female Threaded ��� Weld Outlet Anitilli� No.142 �� Grooved Weld Outlet �� �j 2750 mm — 2"/50 mm Hose Clearance Chart Hose Clearance Chart Dimension i I I I Dimension — j inches inches inches inches inches inches inches inches inches inches mm mm mm mm mm mm mm mm mm mm R Minimum 3 4 5 6 7 R Minimum 3 4 5 6 7 Bend Radius 80 100 125 150 175 Bend Radius 80 100 125 150 175 A Min. 9.4 10.4 11.4 12.4 13.41 A Min. 8.1 9.1 10.1 11.1 12.1 239 264 290 315 341 205 231 256 , 281 307 • • 10.85 5839 Rev AK Updated 03/2021 ®2021 Victaulic Company.All rights reserved. victaulic.com • 5.0 PERFORMANCE— FRICTION LOSS DATA c pL us Series AH2 and AH2-CC Braided Hoses with Straight 5.75"I140 mm Reducers USTED Style AB2, AB4, AB5 and AB10 Brackets Hose Reducer UL Equivalent Length of Length Nominal Outlet Size 1733.7mm Sch.40 pipe inches inches feet mm Type DN meters Max Bends 790 Straight 3 DN15 4.6 790 Straight DN15 4.9 4 79031 3/4 9.0 Straight DN20 15.8 3 790 Straight DN20 26.10 4 36 Y2 9 5 Straight DN15 15.0 3 36 1 21.0 915 Straight 5 DN15 6.4 9 5 Straight 3 DN20 6.4 3 915 Straight DN20 730 5 1220 Straight DN15 61.4 3 48 1/2 32.0 1220 Straight 8 DN15 9.848 3/4 2 t 1220 Straight DN20 7.9 3 41220 Straight I DN20 113 8 • 1505 Straight DN15 872 3 1 60 Straight /z 46.0 10 1525 DN15 14.0 1 61505 Straight DN20 8.260 3 1525 DN20 DN20 14.0 10 72 1 1830 Straight 3 DN15 9.4 72 1/2 55.0 j 1830 Straight 12 DN15 16.8 72 /4 1830 Straight DN20 9.10 3 3 60.0 72 Straight 1 /` 12 1830 ---�.- DN20 1 18.3 • • 10.85 5839 Rev AK Updated 03/2021 ©2021 Victaulic Company.All rights reserved. victaulic.com • 5.0 PERFORMANCE — FRICTION LOSS DATA (CONTINUED) UL Series AH2 and AH2-CC Braided Hose with 90° Low Profile Elbows CuS USTED Style AB11 VicFlex Bracket Hose Reducer UL Equivalent Length of Length Nominal Outlet Size 1'Y33.7mm Sch.40 pipe inches inches feet 1 mm Type DN meters Max Bends 31 LP Elbow 1/2 18.0 3 790 DN15 5.5 31 LP Elbow 1/2 24.0 790 DN15 7.3 4 31 LP Elbow 3/4 21.0 790 DN20 6.4 3 I 31 LP Elbow 3A 24.0 4 790 DN20 7.3 36 V2 19.0 915 LP Elbow DN15 5.8 3 36 LP Elbow 1/226.0 915 DN15 7.9 5 36 LP Elbow 3/a 23.0 3 ill 915 DN20 7.0 36 LP Elbow 3/4 28.0 5 915 DN20 8.5 48 Y2 23.0 1 1220 LP Elbow DN15 7.0 �' 1220 LP Elbow DN15 13.108 1220 LP Elbow DN20 910 ,..,. 1220 LP Elbow DN20 12.8 8 8.0 "? 15225 LP Elbow DN15 28.5 3 , 15251/2 0 LP Elbow DN15 19.0 4.9 10 615025 LP Elbow DN20 9.46 3 150 3/4 25 LP Elbow DN20 15.200 10 1830 LP Elbow DN15 9.4 3 1830 LP Elbow DN15 69.8 12 1830 LP Elbow DN20 16.0 3 172 830 LP Elbow 34 DN20 63.019.2 12 • • 10.85 5839 Rev AK Updated 03/2021 ©2021 Victaulic Company.All rights reserved. victaulic.com 5.0 PERFORMANCE- FRICTION LOSS DATA (CONTINUED) Series AH2 and AH2-CC Braided Hoses Equivalent Length Design Guide Equivalent length values at various numbers of 90 degree bends at 2751 mm center line bend radius I ! Nominal I I 1 I I Outlet 1 2 3 4 5 6 7 8 9 10 11 12 Length Size ' Bend Bends ' Bends Bends Bends Bends Bends Bends Bends Bends Bends Bends inches I inches feet feet feet feet 1 feet feet feet feet feet feet feet feet mm DN meters meters meters meters meters meters meters meters meters meters meters meters 31 Y2 11.0 13.0 15.0 16.0 _ _ _ _ _ _ _ 790 DN15 3.4 4.0 4.6 4.9 31 3% 12.0 14.0 19.0 20.0 - 790 DN20 3.7 4.3 5.8 6.1 36 ' 14.0 16.0 18.0 19.0 21.0 _ _ _ 915 DN15 4.3 4.9 5.5 5.8 6.4 36 3/4 17.0 19.0 21.0 22.0 23.0 915 DN20 5.2 5.8 6.4 6.7 7.0 48 1/2 18.0 19.0 21.0 23.0 25.0 27.0 30.0 32.0 _ _ 1220 DN15 5.5 5.8 6.4 7.0 7.6 8.2 9.1 9.8 48 3/4 21.0 24.0 26.0 28.0 31.0 33.0 35.0 37.0 - _ _ 1220 DN20 6.4 7.3 7.9 8.5 9.4 10.1 10.7 11.3 60 Y2 21.0 24.0 27.0 30.0 32.0 35.0 37.0 40.0 43.0 46.0 _ _ 1525 DN15 6.4 7.3 8.2 9.1 9.8 10.7 11.3 12.2 13.1 14.0 60 3A 23.0 25.0 27.0 29.0 32.0 34.0 37.0 40.0 43.0 46.0 - 1525 DN20 7.0 7.6 8.2 8.8 9.8 10.4 11.3 12.2 13.1 14.0 72 Y 27.0 29.0 31.0 34.0 37.0 40.0 43.0 46.0 48.0 50.0 52.0 55.0 1830 DN15 8.2 8.8 9.4 10.4 11.3 12.2 13.1 14.0 14.6 15.2 15.8 16.8 72 1 3/4 26.0 28.0 30.0 33.0 37.0 40.0 I 44.0 48.0 1 51.0 54.0 57.0 60.0 1830 1 DN20, 7.9 8.5 9.1 10.1 11.3 12.2 l 13.4 14.6 15.5 16.5 17.4 I 18.3 NOTES: • Values for use with 5.757140mm straight reducers. • The values in this table are provided by the manufacturer for reference only.For friction loss data in accordance with the UL Certification,please refer to pages 19 and 20 of this publication. How to use this Design Guide: • For some systems,it may be advantageous for the designer to calculate the system hydraulics using shorter equivalent lengths associated with fewer than the maximum allowable number of bends.In this case,the designer may select a design number of bends for the job and use the associated equivalent length from the design guide to determine the system hydraulics. • It is possible that the actual installed condition of some of the flexible drops may have more bends than the designer selected.When this happens,the design guide may be used to find equivalent lengths based on the actual installed number of bends for particular sprinkler installations.The system hydraulics can be recalculated using actual equivalent lengths to verify the performance of the system. a • 10.85 5839 Rev AK Updated 03/2021 ®2021 Victaulic Company.All rights reserved. • victaulic.com • • 5.1 PERFORMANCE- FRICTION LOSS DATA Arpo. Series AH2 and AH2-CC Braided Hoses Style AB2, AB3, AB4, AB5, AB7, AB7 Adj., AB8, AB1O, AB12, ABBA and ABMM VicFlex Brackets Maximum Equivalent Number Length of Length of of 90°Bends Stainless Steel Outlet 1733.7 mm at 7'7178mm Flexible Hose K-Factor Size Sch.40 Pipe Bend Radius inches inches Imperial mm feet mm S.I. type meters 1/2 13.8 15 4.2 31 5.6 Straight 790 8.1 1/2 23.5 15 90 Elbow 71 16.6 15 5.1 36 5.6 Straight 2 915 8.1 1/2 15 25.6 90'Elbow 7.8 15 7.1 48 5.6 Straight 1220 8.1 1/2 15 307 90°Elbow 1/2 30.2 15 60 5.6 Straight 9.2 4 1525 8.1 1/2 35.9 15 90'Elbow 10.9 1/2 370 15 11.3 72 5.6 Straight 4 1830 8.1 1/2 15 41.1 90°Elbow 12.5 34 16.8 20 31 8.0 Straight 5.1 790 11.5 3/4 2 16.8 20 90"Elbow 5.1 3/4 20 20 36 8.0 Straight 915 11.5 34 2 20 19•7 90"Elbow 60 34 27.8 20 48 8.0 Straight 8.4 1220 11.5 3/4 3 26.6 20 8.1 90°Elbow FM NOTES: • The Series AH2 hose has been tested and Approved by FM Global for use in wet,dry and preaction systems per NFPA 13,13R,and 13D and FM data sheets 2-0,2-5,and 2-8.FM 1637 standard for safety include,but are not limited to,pressure cycling,corrosion resistance,flow characterisitics,vibration resistance,leakage,mechanical and hydrostatic strength. • EXAMPLE:A 48-inch hose installed with two 30°bends and two 90°bends is permitted and considered equivalent to the data in the table shown above.In this example,the total number of degrees is 240°,which is less than the allowable 270°. • • 10.85 5839 Rev AK Updated 03/2021 C 2021 Victaulic Company.All rights reserved. ir 'victaulic.com • • 5.1 PERFORMANCE- FRICTION LOSS DATA (CONTINUED) ® Series AH2 and AH2-CC Braided Hoses Style AB2, AB3, AB4, AB5, AB7, AB7 Adj., AB8, AB10, AB12, ABBA and ABMM VicFlex Brackets Maximum Equivalent Number Length of Length of of 90°Bends Stainless Steel Outlet 1'/33.7 mm at 7"/178 mm Flexible Hose K-Factor Size Sch.40 Pipe Bend Radius inches inches Imperial • mm feet mm S.I. type meters 3/4 35.7 20 10.9 60 8.0 Straight 4 1525 11.5 3A 33.6 20 10.2 90°Elbow 3/4 20 43.5 72 8.0 Straight 13.2 4 1830 11.5 3/4 40.6 20 12.2 90'Elbow 20 16.5 31 11.2 Straight 5.0 2 790 16.1 3/4 17.8 20 5.4 90°Elbow 3/4 19.5 20 5.9 36 11.2 Straight 2 915 16.1 3/4 20.7 20 6.3 , 90°Elbow 3/4 26.7 20 8.1 48 11.2 Straight 3 1220 16.1 3/427.9 20 8.5 90°Elbow 3/4 33.9 20 10.3 60 11.2 Straight 1525 16.1 3 4 /4 20 35 90°Elbow 10.7 3/4 41.3 20 12.5 72 11.2 Straight 4 1830 16.1 3A 42.2 20 12.8 90°Elbow 3A 14.9 20 4.5 31 14.0 Straight 2 790 20.2 3/4 15.5 20 4.72 90°Elbow FM NOTES: • The Series AH2 hose has been tested and Approved by FM Global for use in wet,dry and preaction systems per NFPA 13,13R,and 13D and FM data sheets 2-0,2-5,and 2-8.FM 1637 standard for safety include,but are not limited to,pressure cycling,corrosion resistance,flow characterisitics,vibration resistance,leakage,mechanical and hydrostatic strength. • EXAMPLE:A 48-inch hose installed with two 30°bends and two 90°bends is permitted and considered equivalent to the data in the table shown above.In this example,the total number of degrees is 240°,which is less than the allowable 270°. • •10.85 5839 Rev AK Updated 03/2021 ©2021 Victaulic Company.All rights reserved. victaulic.com • • 5.1 PERFORMANCE— FRICTION LOSS DATA (CONTINUED) ® Series AH2 and AH2-CC Braided Hoses Style AB2, AB3, AB4, AB5, AB7, AB7 Adj., AB8, AB10, AB12, ABBA and ABMM VicRex Brackets Maximum Equivalent Number Length of Length of of 90° Bends Stainless Steel Outlet 1'/33.7 mm at 77178 mm Flexible Hose K-Factor Size Sch.40 Pipe Bend Radius inches inches Imperial mm feet mm S.I. type meters 3/4 20 19.4 36 14.0 Straight 5.9 915 20.2 3A 2 20 19.6 90°Elbow 5.9 3/4 20 30.3 48 14.0 Straight 9.2 1220 20.2 3/4 3 20 29.5 90'Elbow 8.9 3/4 20 33.9 60 14.0 Straight 10.3 1525 20.2 3 4 /4 20 34.1 90'Elbow 10.4 3/4 20 37.5 72 14.0 Straight 11.4 4 1830 20.2 3% 20 38.6 90°Elbow 11.7 FM NOTES: • The Series AH2 hose has been tested and Approved by FM Global for use in wet,dry and preaction systems per NFPA 13,13R,and 13D and FM data sheets 2-0,2-5,and 2-8.FM 1637 standard for safety include,but are not limited to,pressure cycling,corrosion resistance,flow characterisitics,vibration resistance,leakage,mechanical and hydrostatic strength. • EXAMPLE:A 48-inch hose installed with two 30°bends and two 90°bends is permitted and considered equivalent to the data in the table shown above.In this example,the total number of degrees is 240°,which is less than the allowable 270°. • • 10.85 5839 Rev AK Updated 03/2021 0 2021 Victaulic Company.All rights reserved. I victaulic.com 5.2 PERFORMANCE- FRICTION LOSS DATA ® Series AH2 Braided Hose with 90° Low Profile Elbows Style AB5, AB11, AB12, ABBA and ABMM VicFlex Bracket Maximum Equivalent Number Length of Length of of 90°Bends Stainless Steel Outlet 1733.7mm at 7/178mm Flexible Hose K-Factor Size Sch.40 Pipe Bend Radius inches Imperial Inches feet mm S.I. mm meters 31 5.6 H. 'h 13.7 2 790 8.1 1 15 4.2 36 5.6 Y 17.0 2 915 8.1 15 5.2 48 5.6 'h 25.0 3 1220 8.1 15 7.6 60 5.6 1/2 33.0 4 1525 8.1 15 10.1 72 5.6 Y2 41.1 4 1830 8.1 15 12.5 31 8.0 3A 13.6 2 790 11.5 20 4.14 36 8.0 3A 16.9 2 915 11.5 20 5.2 48 8.0 3A 27.8 3 1220 11.5 20 8.5 60 8.0 3/4 32.6 4 1525 11.5 20 9.9 72 8.0 3/4 40.6 I 4 1830 11.5 20 12.4 31 11.2 3/4 13.7 2 790 16.1 20 4.2 { 36 11.2 3A 17.0 2 1 915 16.1 20 5.2 48 11.2 'A 24.9 3 1220 16.1 20 7.6 60 11.2 3A 32.9 4 1525 I 16.1 20 10.0 72 1 11.2 3A 40.9 4 1830 16.1 20 12.5 31 14.0 3/4 13.5 2 790 20.2 I 20 4.1 36 14.0 3/4 16.8 2 915 20.2 20 5.1 48 ! 14.0 3/4 24.7 3 1220 20.2 20 7.5 60 14.0 3/4 32.7 4 1525 20.2 20 9.9 72 14.0 3/4 40.7 4 1830 20.2 20 ( 12.4 FM NOTES: • The Series AH2 hose has been tested and Approved by FM Global for use in wet,dry and preaction systems per NFPA 13,13R,and 13D and FM data sheets 2-0,2-5,and 2-8.FM 1637 standard for safety include,but are not limited to,pressure cycling,corrosion resistance,flow characterisitics,vibration resistance, leakage,mechanical and hydrostatic strength. • EXAMPLE:A 48-inch hose installed with two 30°bends and two 90°bends is permitted and considered equivalent to the data in the table shown above.In this example,the total number of degrees is 240°,which is less than the allowable 270°. • • 10.85 5839 Rev AK Updated 03/2021 ©2021 Victaulic Company.All rights reserved. victaulit, cacti • 5.3 PERFORMANCE - FRICTION LOSS DATA (VdS) Series AH2 and AH2-CC Braided Hose Style AB2, AB4, AB5, AB7, AB7 Adj., AB8, AB10, AB11 and AB12 Brackets Equivalent Length of Length of steel pipe according to Stainless Steel Outlet EN 10255 DN 25 Maximum Number Flexible Hose Size (33,7 x 3,25) of 90"Bends at mm DN meters 3'776.2 mm Bend inches inches feet Radius DN15 790 h 5.5 3 31 DN20 18.0 34 DN15 wW. 915 �1/2 6.4 3 36 DN20 21.0 3/4 DN15 1220 '/z 8.5 3 48 DN20 27.9 3A DN15 1525 /z 10.7 4 60 DN20 35.1 34 DN15 �..,,.. 1830 /z 12.8 4 72 DN20 42.0 3/4 VdS Ceiling Manufacturers List AB2,AB7,AB10,AB11 AB4 AB5,AB8 1.AMF No specific approval 1.Hilti 2.Armstrong 2.Knauf 3.Chicago Metallic 3.Lafarge 4.Dipling 4.Lindner 5.Durlum 5.Rigips 6.Geipel 7.Gema-Armstrong 8.Hilti 9.Knauf 10.Lafarge 11.Linder 12.Odenwald 13.Richter 14.Rigips 15.Rockfon Pagos 16.Suckow&Fischer 17.USG Donn • • 10.85 5839 Rev AK Updated 03/2021 ©2021 Victaulic Company.All rights reserved. Vit:ta tll<;.COiii • • 5.3 PERFORMANCE- FRICTION LOSS DATA Series AH2 and AH2-CC Braided Hose Series AH2 Braided Hose LPCB Style AB2, AB3, AB4, AB5, AB7,AB8, Style AB2, AB3, AB4, AB5, AB7, AB8, AB10 �o•�=a���- , and AB10 Brackets © and AB12 Brackets 10004 Length of Equivalent Length Maximum Stainless of steel pipe Number of Equivalent Length of Steel according to 190"Bends at Length of 1133.7 mm Sch.40 Pipe Flexible Outlet EN 10255 DN 25 3'776.2 mm Flexible Hose Size (33,7 x 3,25) Bend Radius Hose Straight Configuration I Bend Configuration mm mm inches meters mm meters meters inches type feet inches feet feet 15 mm v 790 Straight 1.8 2 790 0.87 2.70 31 20mm 6.0 31 2.9 8.9 3/4 Straight 15 mm 1/2 915 Straight 3.6 3 915 1.00 2.80 36 20mm 11.9 36 3.3 9.2 3/4 Straight 15mm Y2 1220 Straight 4.3 3 1220 2.23 4.66 48 20 mm 14.0 48 7.3 15.3 3% Straight 15mm i 1525 Straight 4.1 3 1525 2.90 6.5 60 20mm 13.6 60 9.5 21.3 3/4 Straight 15mm Y2 1830 Straight _ 5.5 3 1830 3.31 7.16 72 20mm 18.1 72 10.9 23.5 3/4 Straight ' CCCF NOTE • Friction loss data is in accordance with GB5135.16 tested at a flow rate of 114 liters per minute(30 gallons per minute). • • 10.85 5839 Rev AK Updated 03/2021 0 2021 Victaulic Company.All rights reserved. victaulic.com 6.0 NOTIFICATIONS • • Read and understand all instructions before attempting to install Vop, any Victaulic products. • Always verify that the piping system has been completely depres- 0surized and drained immediately prior to installation, removal, adjustment, or maintenance of any Victaulic products. • Wear safety glasses, hardhat, and foot protection. • These products shall be used only in fire protection systems that are designed and installed in accordance with current, applicable National Fire Protection Association (NFPA 13, 13D, 13R, etc.) standards, or equivalent standards, and in accordance with applicable building and fire codes. These standards and codes contain im- portant information regarding protection of systems from freezing temperatures, corrosion, mechanical damage, etc. • The installer shall understand the use of this product and why it was specified for the particular application. • The installer shall understand common industry safety standards and potential consequences of improper product installation. • It is the responsibility of the system designer to verify suitability of 300-series stainless steel flexible hose for use with the intended fluid media within the piping system and external environments. • The effect of chemical composition, pH level, operating temperature, chloride level, oxygen level, and flow rate on 300-series stainless steel flexible hose must be evaluated by the material specifier to confirm system life will be acceptable for the intended service. • It is the responsibility of the owner of a building or their authorized agent to provide the sprinkler system installer with any knowledge that the water supply might be contaminated with or conducive to the development of micro- biologically influenced corrosion (MIC), including as required by NFPA 13. Failure to identify adverse water quality issues may affect the VicFlex product and void the manufacturer's warranty. Failure to follow these instructions could cause product failure, resulting in serious personal injury and/or property damage. Victaulic VicFlex Series AH2 and AH2-CC Flexible Sprinkler Fittings may be painted provided the paint is compatible with stainless steel and zinc-plated carbon steel or ductile iron. Care should be taken to ensure the sprinkler and associated escutcheon or coverplate are not painted. Victaulic VicFlex Series AH2 and AH2-CC penetrating through non-fire rated gypsum wall (drywall)will function as designed, provided the components are installed in accordance with the respective installation instructions referenced in this document. • 10.85 5839 Rev AK Updated 03/2021 ©2021 Victaulic Company.All rights reserved. urrrrrrrat . victaulic.com 7.0 REFERENCE MATERIALS -CHARACTERISTICS VicFlex Maximum Load Values Series AH2 Hose with 24" Bracket Actual Length 1 Total Load Max.Uniform Load t ft 1 _ Model Size m lb ! N lb/linear ft N/linear m 31/790 0:8 5.2 23 2.6 38 36/915 p 9 5.5 25 2.8 40 48/1220 1 2 6.3 28 3.1 46 60/1525 155 7.0 31 3.5 51 72/1830 1 8 7.7 34 3.9 57 Series AH2 Hose with 48" Bracket Actual Length Total Load Max.Uniform Load , ft Model Size m lb N lb/linear ft N/linear m 31/790 $ 6.1 27 1.5 22 0.36/915 9 6.4 29 1.6 23 0. 48/1220 1.2 7.2 32 1.8 26 60/1525 155 7.9 35 2.0 29 72/1830 1 8 8.7 39 2.2 32 Total Load is defined as the sum of the weights of the following: • water-filled flexible sprinkler hose with threaded end fittings, including a typical fire sprinkler • bracket assembly (any applicable Victaulic bracket model of the relevant associated size) ASTM C 635: Suspension System Load-Carrying Capabilities (excerpted) 1 Actual Length Min.Allowable Uniform Load Suspension System ft/m lb/linear ft N/linear m Light 5.0 75.7 Direct Hung Intermediate 12.0 181.0 Heavy 16.0 241.7 SUMMARY: All direct-hung suspension system duty classifications per ASTM C 635 are able to withstand the maximum water-filled weight of the VicFlex sprinkler hose and bracket. • 10.85 5839 Rev AK Updated 03/2021 ©2021 Victaulic Company.All rights reserved. victaulic.com 7.0 REFERENCE MATERIALS—CHARACTERISTICS (CONTINUED) • Flexible Hose In-Plane Bend Characteristics • One Bend Two Bends Three Bends 2x •• 2X Minimum Minimum Minimum bend radius bend radius bend radius • OR Minimum OR bend radius Minimum Minimum '1Y I bendradius �I Minimum ` -- — bendbend radius radius • Minimum • bend radius �-- Minimum bend radius NOTE For out-of-plane (three-dimensional) bends, care must be taken to avoid imparting torque on the hose. I-VicFlex-AB1-AB2 I-VicFlex-AB3 J-VicFlex-AB4 I-VicFlex-AB5 I-VicFlex-AB7 j-VicFlex-AB12 I-VicFlex-ABBA I-VicFlex-ABMM I-RES • • User Responsibility for Product Selection and Suitability Note Each user bears final responsibility for making a determination as to the suitability of This product shall be manufactured by Victaulic or to Victaulic specifications.All products Victaulic products for a particular end-use application,in accordance with industry to be installed in accordance with current Victaulic installation/assembly instructions. standards and project specifications,and the applicable building codes and related Victaulic reserves the right to change product specifications,designs and standard regulations as well as Victaulic performance,maintenance,safety,and warning equipment without notice and without incurring obligations. instructions.Nothing in this or any other document,nor any verbal recommendation, Installation advice,or opinion from any Victaulic employee,shall be deemed to alter,vary,supersede, Reference should always be made to I-VICFLEX-AB1-AB2-AB10,I-VICFLEX-AB4, or waive any provision of Victaulic Company's standard conditions of sale,installation I-VICFLEX-AB7,or I-VICFLEX-AB8 for the product you are installing.Handbooks are guide,or this disclaimer. included with each shipment of Victaulic products for complete installation and assembly Intellectual Property Rights data,and are available in PDF format on our website at www.victaulic.com. No statement contained herein concerning a possible or suggested use of any material, Warranty product,service,or design is intended,or should be constructed,to grant any license Refer to the Warranty section of the current Price List or contact Victaulic for details. under any patent or other intellectual property right of Victaulic or any of its subsidaries or affiliates covering such use or design,or as a recommendation for the use of such Trademarks material,product,service,or design in the infringement of any patent or other intellectual Victaulic and all other Victaulic marks are the trademarks or registered trademarks of property right.The terms"Patented"or"Patent Pending"refer to design or utility patents Victaulic Company,and/or its affiliated entities,in the U.S.and/or other countries. or patent applications for articles and/or methods of use in the United States and/or other countries. • • 10.85 5839 Rev AK Updated 03/2021 ©2021 Victaulic Company.All rights reserved. Mechanical Anchoring Systems KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor 3.3.7 3.3.7.1 Product description 3.3.7.1 Product description Hilti KWIK HUS-EZ I (KH-EZ I)anchors • Thread design enables quality 3.3.7.2 Material specifications are comprised of a body with an setting and exceptional load 3.3.7.3 Technical data internally threaded hex washer head. values in wide variety of base material strengths. 3.3.7.4 Installation instructions The anchor is manufactured from carbon steel and is heat treated. • Anchor is fully removable 3.3.7.5 Design guidelines It has a minimum 0.0003 inch(8 pm) • Anchor size is same as drill 3.3.7.6 Ordering information bit size and uses standard zinc coating in accordance with ANSI B212.15- 1994 drill bits. DIN EN ISO 4042.The internally "', • Suitable for reduced edge , threaded head is larger than the ; 1 distances and spacing. 4 4 diameter of the anchor and is formed with serrations on the underside.The 3.3.7.2 Material anchor body is formed with threads specifications , ^itiiiiil running most of the length of the Hilti KWIK HUS-EZ I anchors are ;r, ' anchor body.The anchor is installed in manufactured from carbon steel. 4 a predrilled hole with a powered impact The anchors are bright zinc plated to f, wrench or torque wrench.The anchor a minimum thickness of 8 pm. I threads cut into the concrete on the 3.3.7.3 Technical 1 I sides of the hole and interlock with data the base material during installation. ( 3.3.7 Applicable base materials include The data contained in tables 1-4 of normal-weight concrete,structural this section have been evaluated in lightweight concrete and lightweight accordance with AC 193. For more 4% R concrete over metal deck. detail,see ICC-ES ESR 3027. ;f ' Guide specifications Figure 1 — KWIK HUS-EZ I anchor g installation details -.- Screw anchors shall be I KWIK HUS-EZ I as supplied by 1, .11 Hilti, Inc.Anchors shall be manufactured from heat treated -- wrench size carbon steel material,zinc plated to a _ Listings/Approvals minimum thickness of 8 pm.Anchors �M da ICC-ES(International Code Council) shall be installed using a drill bit of p ESR-3027 Cracked&Uncracked Concrete) same nominal diameter as anchor. City of Los Angeles Ia^oh O. he h Research Report No.25897 Product features i ho FM Approved • Suitable for cracked and .11111 uncracked normal weight p LA DB$ and lightweight concrete, and = APPROVED lightweight concrete over dbir--- metal deck. Independent code evaluation • Suitable for seismic and IBC®/IRC®2009 nonseismic loads. IBC IBC® IRC®2003 IBC®/IRC 2003 • Quick and easy to install. Hilti,Inc.(US)1-800-879-8000 I www.us.hilti.com I en espanol 1-800-879-5000 I Hilti(Canada)Corp.1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 249 Mechanical Anchoring Systems 3.3.7 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor Table 1 - KWIK HUS-EZ I specifications' Nominal anchor Setting diameter information Symbol Units 1/4 Nominal bit diameter dbh 1/4 Nominal embedment h50,, in. 1-5/8 2-1/2 Effective embedment he} in. 1.18 1.92 Minimum hole depth hp in. 2 2-7/8 Fixture hole diameter dh in. 3/8 ft-lb 4 Installation torque Tins (Nm) (5) Wrench size in. 7/16 1 T,,,is the maximum installation torque that may be applied with a torque wrench. Table 2-Calculated ACI 318-11 Appendix D strength design capacity for single anchor in tension1,2,3,45 Normal-weight concrete Lightweight over metal deck' f',=2500 psi' f' =4000 psi f'e=3000 psi2 Uncracked Cracked Internal Nominal concrete concrete Anchor thread embedment Uncracked Cracked Uncracked Cracked Lower Upper Lower Upper size size in. concrete concrete Seismic concrete concrete Seismic flute flute flute flute 1/4-20 1-5/8 587 300 240 675 346 277 545 670 280 342 1/4 x 1-5/8 UNC 3/8-16 1-5/8 587 300 240 675 346 277 545 670 280 342 UNC 1/4-20 2-1/2 1,533 758 758 1,940 958 958 1,218 1,275 605 634 1/4 x 2-1/2 UNC 3/8-16 2-1/2 1,533 758 758 1,940 958 958 1,218 1,275 605 634 UNC 1 Based on single anchor with edge and spacing values greater than those given as critical values in table 1. 2 Based on lower value of concrete breakout or pullout strength. 3 These loads are factored resistance loads in accordance with chapter 9 of ACI 318-11. 4 Interpolation of values for other embedments is not permitted. 5 Minimum concrete thickness and edge distance must comply with table 1. 6 Tabular values for normal-weight conduct may be adjusted for higher compressive strengths using a multiplication factor of(f' /2,500)°.3 for 1-5/8 in. embedment and(f /2,500)°5 for 1-5/8 in.embedment. 7 Tabular values for lightweight conduct may be adjusted for higher compressive strengths using a multiplication factor of(f',,/3,000)°.3 for 1-5/8 in.embedment and(f'c/3,000)°.5 for 1-5/8 in.embedment. Table 3- KWIK HUS-EZ I(KH-EZ I)allowable stress design values for illustrative purposes1,2,3,4,s,e,7,8,s,10,11 Nominal anchor diameter Nominal embedment,h.om Effective embedment,hay Allowable tension load Internal thread size in. in. in. lb 1-5/8 1.18 470 1/4-20 UNC or 3/8-16 UNC 1/4 2-1/2 1.92 1,340 1 Single anchor with static tension load only. 2 Concrete determined to remain uncracked for the life of the anchorage. 3 Load combinations are taken from ACI 318 section 9.2(no seismic loading). 4 40%dead load and 60%live load,controlling load combination 1.2D+1.6L. 5 Calculation of weighted average for conversion factor a=1.2(0.4)+1.6(0.6)=1.44. 6 Minimum compressive strength of normal-weight concrete is 4,000 psi. 7 Edge distance ca,=c,z ca.See table 1. 8 Slab thickness h z hm See table 1. 9 Values are for Condition B where supplementary reinforcement in accordance with ACI 318 D.4.4 is not provided. 10 Allowable tension load equals the lesser of Nu or the Concrete Breakout from table 1 divided by a factor 1.44. 11 Values are for single anchors installed without influence of base material edge distance or adjacent anchors. 250 Hilti,Inc.(US)1.800.879.8000 I www.us.hilti.com I en espanol 1-800-879-5000 I Hilti(Canada)Corp.1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 Mechanical Anchoring Systr ms KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor 3.3.7 Figure 2-Installation of KWIK HUS-EZ I(KH-EZ I)in soffit of concrete over steel deck floor and roof assemblies Min.3/4" Min.3,000 psi sand-lightweight co or normal-weight concrete 'Co Upper flute 6 " (valley) `\ Min.4-1/2" \ Minimum (typical) 20 gauge } steel deck Min.4-1/2" Anchor Flute edge Lower flute (typical) Min.12"(typical) (ridge) Min.1-1/4"---- 1 Anchors may be placed in the upper or lower flute of the steel deck profile provided the minimum concrete cover above the drilled hole is satisfied.Anchors in the lower flute may be installed with a maximum 1-inch offset in either direction from the center of the flute.The offset distance may be increased proportionally for profiles with lower flute widths greater than those shown provided the minimum lower flute edge distance is also satisfied. Table 4- KWIK HUS EZ I(KH-EZ I)Allowable stress design tension values for installations in soffit of concrete 3.3.7 over steel deck floor and roof assemblies1,2,3,4,s,e,l,s,a,1o,m Tension Nominal anchor diameter Nominal embedment Effective embedment lb Internal thread size in. in. in. Upper flute Lower flute 1-5/8 1.18 466 378 1/4-20 UNC or 3/8-16 UNC 1/4 2-1/2 1.92 885 846 1 Single anchor with static tension load only. 2 Concrete determined to remain uncracked for the life of the anchorage. 3 Load combinations are taken from ACI 318 section 9.2(no seismic loading). 4 40%dead load and 60%live load,controlling load combination 1.2D+1.6L. 5 Calculation of weighted average for conversion factor a=1.2(0.4)+1.6(0.6)=1.44. 6 Minimum compressive strength of lightweight or normal-weight concrete is 3,000 psi. 7 Edge distance ca,=ca t ca.See table 1. 8 Slab thickness h>_h .See table 1. 9 Values are for Condition B where supplementary reinforcement in accordance with ACI 318 D.4.4 is not provided. 10 Allowable tension load equals the factored load from table 2 divided by 1.44. 11 Values are for single anchors installed without influence of base material edge distance or adjacent anchors. Hilti,Inc.(US)1-800-879-8000 I www.us.hilti.com I en espanol 1-800-879-5000 I Hilti(Canada)Corp.1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 251 Mechanical Anchoring Systems otai Est satsim:d 3.3.7 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor Table 5- KWIK HUS-EZ I(KH-EZ)tested load values for FM approval for automatic sprinkler systems' FM maximum Nominal embedment FM tension test load pipe diameter Hanger rod size in. lb in. 3/8-16 UNC 1-5/8 1,475 4 2-1/2 1 Tested in accordance with FM Approval Standard for Pipe Hanger Components for Automatic Sprinklers Systems Class Numbers 1951,1952 and 1953. Table 6- KWIK HUS-EZ I(KH-EZ I)allowable stress design values for installations into hollow core concrete panels"2 Min.effective Allowable load3 Ultimate load embedment her Hanger rod size in. Tension lb Shear IV' Tension lb Shear Ib4'5 1/4-20 UNC 485 1,930 1-3/8 455 1,810 3/8-16 UNC 755 3,025 1 The admissible anchor location must be established to prevent damage to the prestressed cable during the drilling process. Verify the location and height of the cable with the hollow core plank supplier to confirm admissible anchor location. 2 Minimum compressive strength of prestressed concrete is 7,000 psi.Published ultimate loads represent the average results conducted in local base materials. Due to variations in materials and dimension)configurations,on-site testing is required to determine the actual performance. 3 Allowable loads calculated with a factor of safety of 4 4 The bottom of the shear plane adjacent to the top of the coupler. 5 Shear values controlled by the steel strength of the screws used to fasten the shear fixture to the KH EZ-I Screw Anchor.The minimum tensile strength of the screw was 125 ksi.Shear design values should consider the screw or threaded rod steel strength. Figure 3- Installation of KWIK HUS-EZ I(KH-EZ I)in hollow core concrete 41). • Admissible anchor location i Flo 1" 1" t 3.3.7.4 Installation instructions Installation Instructions For Use(IFU)are included with each product package.They can also be viewed or downloaded online at www.us.hilti.com(US)and www.hilti.ca(Canada). Because of the possibility of changes, always verify that downloaded IFU are current when used. Proper installation is critical to achieve full performance.Training is available on request.Contact Hilti Technical Services for applications and conditions not addressed in the IFU. 3.3.7.5 Ordering information' Internal thread Internal thread Hole Minimum Description diameter length diameter embedment Qty/box KH-EZ 1/4x1-5/811/4 1/4 3/8 1/4 1-5/8 100 KH-EZ 1/4x2-1/211/4 1/4 3/8 1/4 2-1/2 100 KH-EZ 1/4x1-5/813/8 3/8 7/16 1/4 1-5/8 100 KH-EZ 1/4x2-1/213/8 3/8 7/16 1/4 2-1/2 100 1 All dimensions in inches. 252 Hilti,Inc.(US)1-800-879-8000 I www.us.hilti.com I en espanol 1-800-879-5000 I Hilti(Canada)Corp.1-800-363-4458 I www.hitti.ca I Anchor Fastening Technical Guide 2014 111 SAMMY X-PRESS° Installs into Metal Deck, Purlin, or Tubular Steel ' SAMMY X-PRESS® - Vertical Application Application Product Features 11 •The Sammy X Press expands to provide •Less jobsite material needed. direct vertical attachment in: (XP) - light gauge steel deck or purlin •No retaining nut required. (22 ga.-1i8"). ..E" •Provides design flexibility. •Installs in seconds with Sammy X-Press It°Tool, tt,; saving time&installation costs. •Manufactured in the U.S.A. Use in applications where access to the back of the installed fastener is prohibited.ie.metal roof deck,tubular steel,or vapor barrier fabric. ,, Watch a video demonstration at P www.itw6uildex.com Approvals Rod Part Model Description Ultimate UL Test UL Min FM Test FM Min Max Box Case Application Size Number Pullout(Ibs) Load(Ibs) Thick Load(Ibsl Thick Thick Qty Qty VERTICAL MOUNT 1= Sammy 185(Luminaire) .027" 1/4" 8181922 XP 200 X-Press 200 1146(22 ga) 250(Luminaire) 056° 125' 25 125 Metal Deck 850(2%"Pipe) .027" 940 (2"Pipe) .029" ;C,) • 3/8" 8150922 XP 20 Sammy 1146(22 gal 185(Luminaire) 027° 1475(4"Pipe) .104" .125" 25 125 Metal Deck X-Press 20 250(Luminaire) .056" 283(Conduit&Cable) .029" 1500(4"Pipe) .060" Sammy 185(Luminaire) .029" 940 (2"Pipe) .029" C1 "•• 318' 8153922 XP 35 X-Press 35 1783(16 ga) 250(Luminaire) .056" 1475 (4"Pipe) .104" .125" 25 125 Purrn 416(Conduit&Cable) .059" Pre-Pour Structural Concrete@ 3000 psi Metal Deck 3/8" 8150922 XP 20 Sammy 1146(22 ga) 850(2'/:Pipe) 25 125 (Pre Pour) X-Press 20 Metal Deck Post-Pour Range II LWC<_35 PCF(Ibs/ft') (Post-Pour) Pre-Pour Structural Concrete @ 3000 psi Post-Pour Range II LWC<_35 PCF(Ibs/ft') r ..I 4.....r A... J. ,J ti—J L ...I-Artr\j: SAMMY X-PRESS SIDEWINDER" - Horizontal Application Application Product Features ! . •The Sammy X-Press Sidewinder expands to •Less jobsite material needed. provide horizontal attachment in: -16 ga-3/16"steel-pudin,tubular steel. •No retaining nut required. .. '" •Installs in seconds with Sammy X-Press It°Tool, •Provides design flexibility. saving time&installation costs. # •Manufactured in the U.S.A. •Use in applications where access to the back of the installed fastener is prohibited;ie.metal roof (SWXP) deck,tubular steel,or vapor barrier fabric. ,th Watch a video demonstration at www.itwbuildex.com Approvals Rod Part Model Description Ultimate UL Test UL Min FM Test Max Box Case Application Size Number Pullout(Ibs) Load(Ibs) Thick Load(Ibs) Thick Qty Qty HORIZONTAL MOUNT Sidewinder 1250(3'/i Pipe) ;� 3l8" 8293957 SWXP 35 X-Press 35 1798(16 ga) 80(Luminaire) .059" .125" 25 125 Purlin 416 (Conduit&Cable) (0 1111 (#711SPI MANUFACTURED U 5 A. For the most up to date information,visit www.itwbuildex.com 8 ,:ici,AHHvo., • el SAMMY X-PRESS SWIVEL" - Swivel Application Application Product Features •The Sammy X-Press Swivel allows you •Less jobsite material needed. to hang plumb in extreme roof pitches: -89°in z-pudin •No retaining nut required. -45°in metal deck for 12/12 pitch • ` MgC •Provides design flexibility. (SXP) ) 6 •Installs in seconds with Sammy X-Press le'Tool, Daggsaving time&installation costs. •Manufactured in the U.S.A. 1 OR V MR �p •Use in applications where access to the back of the installed fastener is prohibited.ie.metal roof P,,yI2 w• Watch a video demonstration al deck,tubular steel,or vapor barrier fabric. www.itwbuildex.com Approvals Rod Part Model Description Ultimate UL Test UL Min FM Test FM Min Max Box Case Application Size Number Pullout(Ibs) Load(Ibs) Thick Load(Ibs) Thick Thick Qty Qty 750(2"Pipe) u l ;, Swivel 1061(22 ga Vert) 170 Vertical(Luminaire) ; 3/8" 8294922 SXP 20 X-Press 20 829(450 Off Vert) 80 @ 45°(Luminaire) .029" 635(2"Pipe) .029" .125" 25 125 Metal Deck j 283 Vertical(Conduit&Cable) ii,, 233 @ 45°(Conduit&Cable) 1250(3-112"Pipe) „� Swivel 1675(16 ga Vert) 250 Vertical(Luminaire) Q"`_r. 3/8" 8295922 SXP 35 X-Press 35 1558(89°Off Vert) 80 @ 90°(Luminaire) .059" 635(2"Pipe) .029" .125" 25 125 Purlin 500 Vertical(Conduit&Cable) 333 @ 89°(Conduit&Cable) 1/2" 8272957 SXP 2.0 Swivel 1061(22 ga Vert) .027" .125" 25 125 Metal Deck X-Press 2.0 829(45°Off Vert) 1/2" 8271957 SXP 3.5 Swivel 1675(16 ga Vert) " X-Press 3.5 1558(89°Off Vert) 060 .125" 25 125 Purlin ' II SAMMY X-PRESS l'r Installation Tool Application Product Features •The Sammy X-Press expands to provide a' direct vertical attachment in: ,f< ., -metal deck(22-16 gauge) ., t -z-purlin(18-16 gauge) , t, }n�( z 1 •Manufactured in the U.S.A. 1., i /4: l >,i ®Ww aJtdweb uemdnm o) Part Number Model Description Qty 8194910 UXPIT* Universal X-Press It Tool 1 8152910 XPDB 25/64"Drill Bit 1 'Tool Includes:Sleeve,Bit Receiver,Hex Wrench,and 25/64"Drill Bit. • 9 To find a distributor near you,call 800-BUILDEX Pipe Hangers Fig. 200 - "Trimline" Adjustable Band Hanger (B-Line Fig. B317ONF) ®'rOLCO Fig. 200F - "Trimline" Adjustable Band Hanger with Felt Lining (B-Line Fig. B317ONFF) CC)US Fig. 200C - "Trimline" Adjustable Band Hanger with Plastic Coated (B-Line Fig. B317ONFC) LISTED Fig. 200S - "Trimline" Adjustable Band Hanger with Non-Captured Nut Size Range: Fig. 200 - 1/2" (15mm)thru 8" (200mm) pipe Material: Steel, Pre-Galvanized to G90 specifications Function: For fire sprinkler and other general piping purposes. Knurled - - u swivel nut design permits hanger adjustment after installation. Features: - • (1/2" (15mm)thru 2" (50mm)) Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design ' keeps adjusting nut from separating with hanger. Hanger is easily n ' \ i B installed around pipe. A For hanger with non-captured nut order Fig. 200S. • (21/2" (65mm)thru 8" (200mm)) Spring tension on nut holds it securely in hanger before installation.Adjusting nut is easily removed. ,' Approvals: Underwriters Laboratories listed (1/2" (15mm)thru 8" (200mm)) Fig 1/2. 3/4 in the USA(UL)and Canada (cUL)for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (FM) (3/4" (20mm)thru 8" (200mm)). Fig.200-1 to2002 Fig.2002Vzto2008 Conforms to Federal Specifications WW-H-171 E &A-A-1192A,Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69&SP-58, Type 10. ,. .. Maximum Temperature: 650°F (343°C) q attf Finish: Pre-Galvanized. Stainless Steel materials will be supplied with (2) hex nuts in place of a knurl nut. Order By: Figure number and pipe size L Designed to meet or exceed requirements of c FM DS 2-0. c x a Fig.200 Fig.200C Fig.200F Pipe Size Rod Size A B Approx.Wt./100 Part No. in. (mm) in. (mm) in. (mm) lbs. (kgl "' 200-1/2 1/2" (15) 3/8"-16 31/8" (79.4) 25/8" (66.7) 11 (5.0) 200-3/4 3/4" (20) 3/8"-16 31/8" (79.4) 21/2" (63.5) 11 (5.0) 200-1 1" (251 3/8"-16 33/8" (85.7) 25/8" 166.7) 12 (5.5) 200-11/4 11/4" (321 3/8"-16 33/4" (94.0) 27/8" (73.0) 13 (5.9) 200-11/2 11/2" (40) 3/8"-16 37/8" (98.4) 27/8' (73.0) 14 (6.4) 200-2 2" (50) 3/8"-16 41/2" (114.3) 3" (76.31 15 (6.91 200-21/2 21/2" (65) 3/8"-16 55/8" (142.9) 41/8' (104.7) 27 (12.3) "'"-- 200-3 3" (751 3/8"-16 57/8" (149.1) 4" (101.61 29 (13.3) Fig.200S 200.31/2 31/2" (90) 3/8"-16 73/8" (187.3) 51/4" (133.3) 34 (15.6) 200-4 4" (100) 3/8"-16 73/8" (187.3) 5" (127.0) 35 (16.0) 200-5 5" (125) 1/2"-13 91/8" (231.8) 61/4" (158.7) 66 (30.2) 200-6 6" (150) 1/2"-13 101/8" (257.2) 63/4" (171.4) 73 (33.4) 200-8 8" (200) 1/2"-13 131/8" (333.4) 83/4" (222.2) 136 (62.3) All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. B-Line Fire Protection Solutions 21 Page 1 of3 Fastenal Product Standard REV-06 Date:January 1 1,2019 FASTIC TROD.316 Threaded Rod,316 Stainless Steel This product standard contains the required dimensional,mechanical,performance, and chemical characteristics of the products shown in this purchase order(as applicable to the product). Unless specified below,current revisions of national or international standards shall be applicable as of the date of Fastenal's purchase order and must be adhered to in their entirety. If the order received does not meet these requirements,corrective action maybe issued which could jeopardize your status as an approved supplier to Fastenal. L Diameter Nominal D (Major Diameter) Size Max. Min. #2-56* .0860 .0854 .0813 #4-40* .1120 .1112 .1061 #6-32* .1380 .1372 .1312 #8-32* .1640 .1631 .1571 #10-24* .1900 .1890 .1818 #10-32* .1900 .1891 .1831 1/4-20 .2500 .2489 .2367 1/4-28 .2500 .2490 .2392 5/16-18 .3125 .3113 .2982 5/16-24 .3125 .3114 .3006 3/8-16 .3750 .3737 .3595 3/8-24 .3750 .3739 .3631 7/16-14 .4375 .4361 .4206 7/16-20 .4375 .4362 .4240 *Class 2A threads shall be used for sizes where 1A is not applicable RECORD OF REVISION CHANGES TO THIS DOCUM ENT ARE LOCATED ON THE LAST PAGE Page 2 of 3 Fasten al Product Standard REV-06 Date:January 11,2019 aSTENA ' TROD.316 Diameter Nominal D (Major Diameter) Size Max. Min. 1/2-13 .5000 .4985 .4822 1/2-20 .5000 .4987 .4865 9/16-12 .5625 .5609 .5437 5/8-11 .6250 .6233 .6051 5/8-18 .6250 .6236 .6105 3/4-10 .7500 .7482 .7288 3/4-16 .7500 .7485 .7343 7/8-9 .8750 .8731 .8523 7/8-14 .8750 .8734 .8631 1-8 1.000 .9980 .9755 1-14* 1.000 .9984 .9881 1 1/8-7 1.125 1.1228 1.0982 1 1/8-8* 1.125 1.1229 1.1079 1 1/8-12 1.125 1.1232 1.1060 1 1/4-7 1.250 1.2478 1.2232 1 1/4-12 1.250 1.2482 1.2368 1 3/8-6 1.375 1.3726 1.3544 1 1/4-12 1.250 1.2482 1.2310 1 3/8-6 1.375 1.3726 1.3453 1 1/2-6 1.500 1.4976 1.4703 1 5/8-8* 1.625 1.6228 1.6078 2-4.5 2.000 1.9971 1.9751 *Class 2A threads shall be used for sizes where 1A is not applicable Length Tolerance 3' +/- 1/4" 6' - 12' +/- 1/2" Length shall be measured fromend to end Specification Requirements: • Dimensions: ASMEB18.31.3 • Material: UNS S31600 Stainless Steel • Mechanical Properties: CW,Group 2 perASTM F593 s hall be accepted for all diameters listed in the table above,per their respective tensile stress areas • Thread Requirements: Rolled threads to ASMEBI.1,UNC,UNF,UNS &UN8 Class lA • Product Marking: Marked with predetermined color on rod end. Vendor to supply colorcodewith the MTRand purchase order. • Finish: PerASTMA380/A380M • Material Test Reports: The MTRmust have documented lot traceability,dimensional results,full chemical test results and full mechanical test results to the specification(s)above. In addition,the MTR shall be in full compliance with Fastenal's MTR Requirements. Page 3 of 3 Fasten al Product Standard REV-06 Date:January 11,2019 FASIENAL TROD.316 Revision Level Changes to this Document Document Name Revision Revision Rationale for Revision Level Date TROD.316 06 1/11/2019 Revised finish specification. The rationale above may not include all of the changes within each revision. A complete review of the Fastenal Product Standard is required. CARBON STEEL PIPE - HOLE CUT PRODUCTS 11 .02 Mechanical-T® Bolted Branch Outlets ® VdS LPCB ;; VNIIPO SEE YICTAULIC PUBLICA ION 10.01 FOR DETAILS STYLES 920 AND 920N Victaulic Mechanical-T®Outlet provides a direct branch connection at any location a hole can be cut in pipe.The hole is cut oversize to receive a "holefinder" locating collar which secures the outlet in position permanently.A pressure responsive gasket seals on the pipe O.D. Cross-type connections can be achieved by utilizing two upper housings of the same style and size,with the same or differing branch size connections. NOTE:Style 920 and Style 920N housings cannot be mated to each other to achieve a cross connection. Style 920 and Style 920N Mechanical-T outlets are available with grooved or female threaded STYLES 920 AND 920N STYLE 920 CROSS outlet.Specify choice on order. Units are supplied painted with plated bolts.Galvanized hous- PATENTED ings are available,supplied with plated bolts. All sizes of Style 920 and 920N are rated at 500 psi/3450 kPa working pressure on Schedule 10 and 40 carbon steel pipe.They may also be used on high density polyethylene or poly- butylene(HDPE)pipe. Pressure ratings on HDPE are dependent on the pipe rating.Contact Victaulic for ratings on other pipe.Style 920 and 920N are not recommended for use on PVC plastic pipe. Standard piping practices dictate that the Mechanical-T Styles 920 and 920N must be installed so that the main and branch connections are a true 90°angle when permanently attached to the pipeline surface. Additionally,the Vic Tap II®hole cutting tool,which allows for hole cutting capabilities on pressurized systems,utilizes the Style 920 Mechanical-T in conjunction with the Series 726 Vic-Ball Valve to create the Style 931 Vic-Tap II Mechanical-T unit.See page 8 for further information. MATERIAL SPECIFICATIONS Housing/Coating: Ductile iron conforming to ASTM A-536,grade 65-45-12,with orange enamel coating. Ductile iron conforming to ASTM A-395,grade 65-45-15, is available upon special request. • Optional: Hot dipped galvanized Gasket: (Specify choice*) • Grade"E"EPDM EPDM(Green color code).Temperature range—30°F to+230°F/-34°C to+110°C. Recommended for cold and hot water service within the specified temperature range plus a variety of dilute acids,oil-free air and many chemical services. UL Classified in accordance with ANSI/NSF 61 for cold+86°F/+30°C and hot+180°F/+82°C. NOT RECOMMENDED FOR PETROLEUM SERVICES. • Grade"T"nitrile Nitrile(Orange color code).Temperature range—20°F to+180°F/-29°C to+82°C. Recommended for petroleum products,air with oil vapors,vegetable and mineral oils within the specified temperature range. Not recommended for hot water services over+150°F/+66°C or for hot dry air over+140°F/+60°C. *Services listed are General Service Recommendations only. It should be noted that there are services for which these gaskets are not recommended. Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service recommendations and for a listing of services which are not recommended. Bolts/Nuts:Heat-treated plated carbon steel,trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para Location Date Approved Date CARBON STEEL PIPE- HOLE CUT PRODUCTS 11.02 Mechanical-T® Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS Sr,. r. Run x Branch ' Hole V• # V is Female I Nominal Size 920 (Diameter T" Thd. Grv. W Y Z Thd. 1 Grv. t Y F-Z Inches or psi +0.13 Inches Inches Inches Inches Inches Inches Lbs. 1 Lbs. mm ' 920N 1 kPa -0.00 mm mm mm mm mm mm kg kg 2 x '�(a)° 920N 500 1.50 2.00 2.53 - 1.61 5.35 2.75 3.1 �1 50 15 3450 38.1 51 64 41 136 70 1.5 - ..iii fie3(a)0 920N 500 1.50 1.97 2.53 _ 1.61 5.35 2.75 3.1 20 3450 38.1 50 64 41 136 70 1.5 4A- 14..)&,41, i(a)° 500 1.50 1.85 2.53 _ 1.61 5.35 2.75 3.0 W 4 1 I1 25 920N 3450 38.1 47 64 41 136 70 1.4 � 1/4(a)t° 920N 500 1.75 2.05 2.75 3.00 1.61 5.35 3.00 3.5 3.2 GROOVED OUTLET 32 3450 44.5 52 70 76 41 136 76 1.7 1.5 1 rh(a)to 920N 500 1.75 2.03 2.75 3.12 1.61 5.35 3.25 3.6 3.2 40 3450 44.5 52 70 79 41 136 I 83 1.7 1.5 y z 2 x 'k(a)§° 920N 500 1.50 2.21 2.74 - 1.82 5.64 1 2.75 3.0 + - 65 15 3450 38.1 56 70 46 143 � 70 1.4 - t r PR 1 It -a-16)1 3/a(a)§° 920N 500 1.50 2.18 2.74 1.82 5.64 2.75 3.0 Vm �� n� T 20 3450 38.1 55 70 46 143 70 1.4 1p 1(a)§0 25 500 1.50 2.06 2.74 920N 3450 38.1 52 - 1.82 5.64 2.75 2.9 i 4 =� 70 46 143 70 1.4 y 1 Y4 t(a)a 920N 500 1.75 2.30 3.00 3.25 1.82 6.29 3.00 3.5 3.2 32 3450 44.5 58 76 83 46 160 76 1.7 1.5 500 2.00 2.28 3.00 3.25 1.82 6.26 3.25 3.6 3.3 FEMALE THREADED OUTLET 1 h t(a)° 920N 40 3450 50.8 58 76 83 46 159 83 1.7 1.6 76.1 x /z(a) 920N 300 1.50 2.22 2.75 . - 2.25 6.46 3.18 3.9 - 15 2065 38.1 56 70 t 57 164 81 1.8 • Provides a direct branch connection at 3(a) 300 1.50 2.19 2.75 I 2.25 6.46 3.18 3.9 any location where a hole can be cut 20 920N 2065 38.1 56 70 ] - j 57 164 81 1.8 in the pipe 1(a) 920N 300 1.50 2.07 2.75 - ; 2.25 6.46 3.18 3.8 25 2065 38.1 53 70 57 164 81 1.7 • A pressure responsive gasket provides 1 Y(a)° 920N 500 1.75 2.30 3.00 3.31 1.92 6.29 3.00 3.5 3.2 the seal 32 3450 44.5 58 76 84 49 160 76 1.6 1.5 1/z(a)° 920N 500 2.00 2.28 3.00 3.31 1.92 6.29 3.25 3.5 3.3 • Request Publication 11.03 for 40 3450 50.8 58 76 84 49 160 83 1.6 1.5 Mechanical-T cross assemblies - _ 3 Yz(a)° 500 1.50 2.52 3.05 2.28 6.15 t 2.75 3.4 80 x 15 920N 3450 38.1 64 78 58 156 70 1.6 { • Pressure rated up to 500 psi/3450 kPa 3/4(a)o 920N 500 1.50 2.49 3.05 I 2.28 6.15 2.75 3.4 on steel pipe; also available for use 20 3450 38.1 63 78 j -_ I 58 156 70 1.6 with HDPE pipe 1(a) 920N 500 1.50 2.38 3.06 __I 2.28 6.15 2.75 3.3 25 3450 38.1 61 78 . 58 156 70 1.6 • Sizes from 2 x 1/2"/50 x 15mm 1'/4(a)to 920N 500 1.75 2.55 3.25 3.56 2.28 6.15 3.00 3.8 3.7 through 8 x 4"/200 x 100 mm 32(b) 3450 44.5 65 83 90 58 156 76 1.8 1.8 1/(a)to 920N 500 2.00 2.78 3.50 3.56 2.28 6.15 . 3.25 4.1 3.8 40(b) 3450 50.8 71 89 90 58 156 83 1.9 1.8 2(a)° 920N 500 2.50 2.75 3.50 3.56 2.28 6.75 3.88 4.9 4.6 50 3450 63.5 70 89 90 58 172 99 2.3 2.1 3 1/2 x 2 920N 500 2.50 3.00 , - 3.75 2.44 6.72 3.88 I _ 3.8 90 50 3450 63.5 76 95 62 171 99 1.8 IMPORTANT NOTES: TABLE CONTINUED ON PG.3 Style 920 and Style 920N housings cannot be **Center of run to engaged pipe end,female threaded outlet only(dimensions approximate). mated to one another t Available with grooved or female threaded outlet.Specify choice on order. to achieve cross connections. # Center of run to end of fitting. # Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings. (a)British Standard female pipe threaded outlet is available as listed.Specify"BSPT"clearly on order. (b)For 76.1 mm threaded outlet,specify 21/2'BSPT clearly on order. §Vds approved for fire protection services ❑LPCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company. CARBON STEEL PIPE - HOLE CUT PRODUCTS 11 .02 Mechanical-T® Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS Style Max.Work Approx. Size No. Pressures Weight Each Run x Branch Hole V?# V Female Nominal Size 920 Diameter T' Thd. Grv. W Y Z Thd. I Grv. t Y ► -Z Inches or psi +0.13 Inches Inches Inches Inches Inches Inches Lbs. I Lbs. mm 920N kPa -0.00 mm rem mm mm mm mm kg kg ' TABLE CONTINUED FROM PAGE 2 �� <-----4.9 4 1/2(a)0 500 1.50 3.03 3 56 _ 2.69 7.01 2.75 3.7 _ .n �� iin I fl�l t 100 x 15 920N 3450 38.1 77 90 68 178 70 1.8 ► ,A(a) 920N 500 1.50 3.00 3.56 ; _ 2.69 7.01 2.75 3.7 v 20 3450 38.1 76 90 - 68 178 70 1.8 - y .LJ 1(a)0 500 1.50 2.88 3.56 2.69 7.01 2.75 3.6 25 920N 3450 38.1 73 90 68 178 70 1.8 GROOVED OUTLET 1 Y(a)to 920N 500 1.75 3.08 3.78 4.00 2.69 7.01 3.00 4.0 3.6 32(b) 3450 44.5 78 96 102 68 178 76 1.9 1.8 11/2(a)to 920N 500 2.00 3.28 4.00 4.00 2.69 7.01 3.25 4.2 3.9 Y ). 1 Z ). 40(b) 3450 50.8 83 102 102 68 178 83 2.0 1.9 2(a)to 920N 500 2.50 3.25 4.00 4.00 2.69 7.01 3.88 5.0 4.6 SD 3450 63.5 83 102 102 68 178 99 2.3 2.1 V los �� ��r, T 21/2(a)t 920 500 2.75 2.88 4.00 4.00 2.69 7.34 4.63 5.8 5.0 65 3450 69.9 73 102 102 68 186 118 2.6 2.3 -�� �� 500 2.75 2.88 4.00 2.69 7.34 4.63 6.4 76.1 mm 920 yI 3450 69.9 73 102 68 186 118 2.9 �--L 3(a)t 500 3.50 3.31 4.50 4.12 2.69 7.73 5.12 8.4 6.4 80 920 3450 88.9 84 114 105 68 196 130 3.8 2.9 FEMALE THREADED OUTLET 1 r1/(a)o 500 1.75 3.08 3.78 _ 2.63 7.64 3.05 5.0 108.0 x 32 920N - 3450 44.5 78 96 67 194 78 2.3 1 r/2(ale 920N 500 2.00 3.28 4.00 _ 2.63 7.64 3.25 5.0 • Provides a direct branch connection at 40 3450 50.8 83 102 67 194 83 2.3 - any location where a hole can be cut 2(a) 920N 500 2.50 3.25 4.00 _ 2.63 7.64 4.00 4.0 in the pipe 50 3450 63.5 83 102 67 194 102 1.9 76.1 mm 920 500 2.75 2.88 4.00 4.00 2.63 7.64 4.29 8.0 7.8 • A pressure responsive gasket provides 3450 69.9 73 102 102 67 194 109 3.6 3.5 the seal 3(a) 920 500 3.50 3.31 4.50 4.50 2.63 7.63 4.88 6.8 6.5 80 3450 88.9 84 114 114 67 194 124 3.1 3.0 • Request Publication 11.03 for s 1/z(a)t 500 200 4.03 4.75 4.75 3.16 9.70 3.69 7.4 7.6 Mechanical-T cross assemblies 125 x 40 920 3450 50.8 102 121 121 80 246 94 3.4 3.4 2(a)t 500 2.50 4.00 4.75 4.75 3.16 9.70 4.38 8.2 8.0 • Pressure rated up to 500 psi/3450 kPa 50 920 3450 63.5 102 121 121 80 246 111 3.7 3.6 on steel pipe; also available for use 21/2(a)t 920 500 2.75 3.63 4.75 4.75 3.16 9.70 4.63 8.3 7.9 with HDPE pipe 65 3450 69.9 92 121 121 80 246 118 3.8 3.6 76.1 mm 6 920 500 2.75 3.75 _ 4.75 3.16 9.70 4.63 _ 8.0 • Sizes from 2 x 1 "/50 x 15mm 3450 69.9 95 121 80 246 118 3.6 through 8 x 47200 x 100 mm 3(a)t 920 500 3.50 3.81 5.00 4.63 3.16 9.70 5.31 8.4 8.8 80 3450 88.9 97 127 118 80 246 135 3.8 4.0 2 500 2.50 3.75 4.50 3.17 8.00 3.88 8.0 133.0 x 50 920N _ 3450 63.5 95 114 81 203 99 3.6 3 500 3.50 3.81 5.00 3.00 9.46 5.31 8.0 80 920 3450 88.9 97 127 76 240 135 3.6 TABLE CONTINUED ON PG.4 IMPORTANT NOTES: **Center of run to engaged pipe end,female threaded outlet only(dimensions approximate). Style 920 and Style 920N housings cannot be t Available with grooved or female threaded outlet.Specify choice on order. mated to one another t Center of run to end of fitting. to achieve cross connections. # Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings. (a)British Standard female pipe threaded outlet is available as listed.Specify"BSPT"clearly on order. (b)For 76.1 mm threaded outlet,specify 21/2"BSPT clearly on order. §Vds approved for fire protection services a LPCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company. . . .. Jr .. 4 CARBON STEEL PIPE-HOLE CUT PRODUCTS 1 1.02 Mechanical-T® Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS `.x'yIo Max_Work Size No. Presnirc( 1,- Run x Branch I Hole V t# V ; Female Nominal Size 920 ;Diameter T Thd. Grv. W V Z l Thd. Grv. Y rZ Inches or psi +0.13 Inches Inches Inches Inches Inches Inches l Lbs. Lbs. mm 920N kPa -0.00 mm mm mm mm mm mm kg , kg NMI t -� TABLE CONTINUED FROM PAGE 3 w�i . r 11/2 t 500 Al 2.00 3.78 4.50 3.30 8.23 3.25 7.0 - V 139.7 x 920N rig as 1ill t I r`G 1 I 40 3450 50.8 96 114 84 209 83 3.2 -- 2 t 920N 500 2.50 3.75 4.50 3.30 8.23 3.88 9.0 T 50 3450 63.5 95 114 1 84 209 99 4.1 f w40 6 1 r/,(a) 500 1.75 4.43 5.13 5.13 ' 3.79 9.15 3.25 5.1 4.8 y 150 x 32(b) 920N 3450 44.5 112 130 130 96 232 83 2.3 2.2 GROOVED OUTLET 11/2(a)to 920N 500 2.00 4.40 5.13 5.13 3.79 9.15 3.25 5.4 5.1 40(b) 3450 50.8 112 130 130 96 232 83 2.4 2.3 P.1 2(a)tot 920N 500 2.50 4.38 5.13 5.13 3.79 9.15 3.88 6.0 5.6 y ). I z 50 3450 63.5 111 130 130 96 232 99 2.7 2.5 21/2 920 500 2.75 4.01 5.13 5.12 3.69 10.51 4.63 8.3 7.6 65 3450 69.9 110 130 130 94 267 118 3.8 3.4 V sea goo „'��I r 76.1 mm o 920 500 2.75 4.15 - 5.21 3.69 10.51 4.63 _ 84 3450 69.9 105 132 94 267 118 3.8 = �� _�� 3(a)t 500 3.50 4.31 5.50 5.13 3.69 10.51 5.31 9.9 84 80 920 3450 88.9 110 140 130 94 267 135 4.5 3.8 4(a)to j 920 500 4.50 3.81 5.75 5.38 3.69 10.51 6.25 10.1 10.1 100 3450 114.3 97 146 137 94 267 159 4.6 4.6 FEMALE THREADED OUTLET 1 Yz(a) 500 2.00 4.41 5.13 _ 3.63 9.40 3.25 7.8 159.0 x 40 920N 3450 50.8 112 130 92 239 83 3.5 2(a) 920N 500 2.50 4.38 5.13 _ 3.63 9.40 3.88 8.0 • Provides a direct branch connection at 50 3450 63.5 111 130 92 239 99 3.6 any location where a hole can be cut 76.1 mm! 920 500 2.75 4.38 5.50 5.13 3.63 9.40 4.63 9.5 9.5 in the pipe 3450 69.9 111 140 130 92 239 118 4.3 4.3 3 500 3.50 4.31 5.50 5.13 3.63 9.40 5.31 8.1 14.0 • A pressure responsive gasket provides 80 920 3450 88.9 110 140 130 92 239 135 3.7 6.4 the seal 108.0mm 920 500 4.50 4.45 _ 5.38 3.63 9.40 6.12 10.0 3450 114.3 113 137 92 239 155 4.5 • Request Publication 11.03 for 4 500 4.50 3.81 5.75 3.63 9.40 6.25 18.0 Mechanical-T cross assemblies 100 920 3450 114.3 96.80 146 - 92 239 159 8.2 TABLE CONTINUED ON PG.5 • Pressure rated up to 500 psi/3450 kPa **Center of run to engaged pipe end,female threaded outlet only(dimensions approximate). on steel pipe; also available for use t Available with grooved or female threaded outlet.Specify choice on order. with HDPE pipe # Center of run to end of fitting. • Sizes from 2 x 1/2"/50 x 15mm # Female threaded outlets are available to NPT and BSPT specifications. through 8 x 47200 x 100 mm @ See page 7 for Fire Protection approvals and pressure ratings. (a)British Standard female pipe threaded outlet is available as listed.Specify"BSPT"clearly on order. (b)For 76.1 mm threaded outlet,specify 21/2'BSPT clearly on order. §Vds approved for fire protection services a LPCB approved for fire protection services IMPORTANT NOTES: 0 Approved for use in China by Tianjin Approvals Company. Style 920 and Style 920N housings cannot be mated to one another to achieve cross connections. ,.,,.,W vie*nrrlir ran, I CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-T® Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS Approx. r. ., Dimensions Weight Each Run x Branch Hole V`# V# Female Nominal Sine 920 'Diameter T` Thd. Grv. W Y Z I Thd. Grv, Y 2 Inches or psi 1 +0.13 Inches Inches Inches Inches Inches Inches Lbs. Lbs. mm 920N kPa 0.00 mm nisi sins nan mm mm kg kg 1 TABLE CONTINUED FROM PAGE 4 V �� 165.1 x 1 920N 500 1.50 3.88 4.56 - 3.79 9.34 2.75 8.0 rir i-� oil I t rl�l I J) 1 Y4 500 1.75 4.43 5.13 _ 3.79 9.34 3.25 8.4 _ M• 211 T 32 920N 3450 44.5 113 130 96 237 83 3.8 + v I 1,1(a)to 920N 500 2.00 4.41 5.13 5.13 3.79 9.34 3.25 8.4 5.4 40 3450 50.8 112 130 130 96 237 83 3.8 2.4 GROOVED OUTLET 2(a)t 920N 500 2.50 4.38 5.13 5.13 3.79 9.34 3.88 8.5 6.0 50 3450 63.5 111 130 130 96 237 99 3.9 2.7 76.1 mm 920 500 2.75 4.01 5.13 5.21 3.63 10.51 4.63 8.6 7.6 4 Y E--z ii 3450 69.9 110 130 132 92 267 118 3.9 3.4 3(a)t 0 500 3.50 4.31 5.50 5.13 3.63 10.51 5.31 10.2 8.4 t Pillr 80 920 3450 88.9 110 140 130 92 267 135 4.6 3.8 V +44 + 4(a)to 500 4.50 3.81 5.75 5.38 3.63 10.51 6.25 10.5 8.4 ? If�II 100 920 3450 114.3 97 146 137 92 267 159 4.8 3.8 8 2(a)t 500 2.75 5.44 6.19 6.25 4.81 12.42 4.50 11.6 11.6 y I f j 200 x 50 920 3450 69.9 138 157 159 122 316 114 5.3 5.3 �� 2 Y(a)t 500 2.75 5.07 6.19 6.19 4.81 12.42 4.50 11.6 11.6 65 920 3450 69.9 129 157 157 122 316 114 5.3 5.3 FEMALE THREADED OUTLET 500 2.75 5.25 _ 6.25 4.81 12.42 4.56 _ 11.6 76.1 mm a 920 3450 69.9 133 159 122 316 116 5.3 3(a)to 500 3.50 5.31 6.50 6.50 4.81 12 42 5.31 12.6 11.6 • Provides a direct branch connection at 80 920 3450 88.9 135 165 165 122 316 135 5.7 5.3 any location where a hole can be cut 4(a)to 500 4.50 4.81 6.75 6.38 4.81 12.42 6.25 15.3 12.5 in the pipe 100 920 3450 114.3 122 171 162 122 316 159 6.9 5.7 **Center of run to engaged pipe end,female threaded outlet only(dimensions approximate). • A pressure responsive gasket provides t Available with grooved or female threaded outlet.Specify choice on order. the seal # Center of run to end of fitting. • Request Publication 11.03 for # Female threaded outlets are available to NPT and BSPT specifications. Mechanical-T cross assemblies @ See page 7 for Fire Protection approvals and pressure ratings.' • Pressure rated up to 500 psi/3450 kPa (a)British Standard female pipe threaded outlet is available as listed.Specify"BSPT"clearly on order. on steel pipe; also available for use (b)For 76.1 mm threaded outlet,specify 21/2"BSPT clearly on order. with HDPE pipe 4 Vds approved for fire protection services u LPCB approved for fire protection services • Sizes from 2 x ' "/50 x 15mm 0 Approved for use in China by Tianjin Approvals Company. through 8 x 4'/200 x 100 mm IMPORTANT NOTES: Style 920 and Style 920N housings cannot be mated to each other to achieve cross connections. - Z CARBON STEEL PIPE- HOLE CUT PRODUCTS 11.02 Mechanical-T® Bolted Branch Outlets STYLES 920 AND 920N FLOW DATA Flow test data has shown that the total head loss between point(1)and(2)for the Style 920,920N and 929 Mechanical-T®fittings can best be expressed in terms of the pressure difference across the inlet and branch.The pressure difference can be obtained from the relationship below. 0 C„and Kv Values Values for flow of water at+60°F/+16°C are shown in the table below. Formulas for Cv,K,Values: OP = Q2 Where: AP = Q2 Where: _ /1M C2 Q=Flow(GPM) Cif AP=Pressure Drop(psi) K° Q=Flow(m3/h) ' ee AP=Pressure Drop(bar) Q = Cy x AP C =Flow Coefficient Q = IS, x AP =Flow Coefficient Exaggerated for clarity Equivalent Length of Outlet Size Schedule 40 Carbon Steel Pipe (per UL 213.Sec. 16) OUTLET SIZE !C=120)) F T C J!( Valur NOMINAL ACTUAL ! DIAMETER 0.D. In/mm In/mm GROOVED I THREADED i GROOVED THREADED Y2 0.840 I 2 11 15 21.3 9.4 3/4 1.050 16 20 26.7 4 13.7 1 1.315 I 21 25 33.7 - 8 1.8 1 Y4 1.660 50 48 32 42.7 5/2 6 42.9 41.1 1 Y 1.900 53 53 40 98.3 f 11 11 45.4 45.4 2 2.375 112 104 50 60.3 9 10/z 96 89.1 2 Yz 2.875 119 150 65 73.0 20 ! 12 h 102 128.5 76.1 mm 3.000 16* 161 76.1 138.1 3 3.500 249 237 80 88.9 14 15 h 213.4 203.1 4 4.500 421 401 100 114.3 20 22 360.8 343.6 t Hazen-Williams coefficient of friction is 120. *Pipe with a wall thickness of 0.165inJ4.2mm. smarm,vielm.,I1P rnR'1 , CARBON STEEL PIPE- HOLE CUT PRODUCTS 11 .02 Mechanical-I® Bolted Branch Outlets STYLES 920 AND 920N FIRE PROTECTION APPROVALS AND PRESSURE RATINGS The information provided below is based on the latest listing and approval data at the time of publication. Listings/Approvals are subject to change and/or additions by the approvals agencies. Contact Victaulic for performance on other pipe and the latest listings and approvals. Approval Agency Ri.n Svc Outlet Size Pipe Rated Working Pressures-psi/kPa Actual Nominal Outside Vds Size Diameter Inches/nun Inches/mm Inches/mm Schedule UL ULC FM LPCB (Style 920) (Style 920N) 21/2-6 2.875-6.625 All 10,40 400 400 400 290 232 362 65-150 73.0-168.3 2755 2755 2755 1999 1599 2496 21/2-4 2.875 4.500 All DF 300 300 300 290 232 362 65-100 73.0-114.3 2065 2065 2065 1999 1599 2496 21/2-4 2.875-4.500 All SF 300 300 300 290 232 362 65-100 73.0-114.3 2065 2065 2065 1999 1599 2496 6 6.625 3 4 10 300 300 250 290 232 362 150 168.3 2065 2065 1724 1999 1599 2496 6 6.625 3,4 30,40 300 300 300 290 232 362 150 168.3 2065 2065 2065 1999 1599 2496 8 8.625 21/2 10,40 400 _ _ _ 145 — 200 219.1 2755 1000 8 8.625 3 4 10 300 _ 250 _ 145 200 219.1 2065 1724 1000 8 8.625 145 3,4 30,40 300 _ 300 _ 200 219.1 2065 2065 1000 NOTES: 10 refers to Listed/Approved Schedule 10 steel sprinkler pipe. 40 refers to Listed/Approved Schedule 40 steel sprinkler pipe. DF refers to Listed/Approved Dyna-Flow steel sprinkler pipe manufactured by American Tube Company. SF refers to Listed/Approved Super-Flo steel sprinkler pipe manufactured by Allied Tube and Conduit Corporation. VIC-TAP II HOLE CUTTING TOOL FOR The Vic-Tap II hole cutting tool is designed for use with the Style 931 Vic-Tap II Mechanical-T unit, 4-8"/100-200MM CARBON STEEL PIPE which is a combination of the Style 920 Mechanical-T and Series 726 Vic-Ball Valve.The Vic-Tap II is capable of tapping into carbon steel pipe systems under pressures up to 500 psi/3450 kPa. L The Style 931 Vic-Tap II Mechanical-T unit is a full port ball valve which can be mounted on 47100mm, 5"/125mm,6"/150mm and 8/200 mm diameter pipe.The Style 931 comes with a 21"/65mm grooved outlet. §%; The drill motor is an electric motor with interrupter ground fault circuit (GFCI)in accordance with . safety codes. - For more information, refer to publication 24.01. 1111 , CARBON STEEL PIPE - HOLE CUT PRODUCTS 1 1 ,02 Mechanical-T® Bolted Branch Outlets STYLES 920 AND 920N INSTALLATION Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data,and are available in PDF format on our website at www.victaulic.com. • WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications.All products to be installed in accordance with current Victaulic installation/assembly instructions.Victaulic reserves the right to change product specifications,designs and standard equipment without notice and without incurring obligations. TITUS it TITUS CAST IRON FIRE PROTECTION TECHNICAL BULLETINS • dot www . titusindustrial . corn Pt: (n't 3 SABLE Of CONTENTS 7TITUS CAST IRON 3. 90° ELBOW 4. 90° REDUCED ELBOW 5. 45° ELBOW 6. REDUCED COUPLING 7. CROSS S. REDUCED CROSS 9. TEE 10. REDUCED TEE 11. PLUG CAST IRON ? TITUS 90° ELBOW . • Approved By UL, ULC and FM at 300 psi • Cast Iron ASTM A 126 Class B. • NPT Thread per ANSI/ASME B1.20.1. • Dimension per ASME B16.4 '> • Marked with SPD • For current listing/approval details contact a Titus representative cOus ®' APPROVED Nominal Size Pressure Dimension Unit WT in/mm CODE PSI/MPa A B LB/KGS 1 CB90033 300 1.50 1.50 0.90 25 2065 38.1 38.1 0.41 1-1/4 CB90044 300 1.75 1.75 1.39 32 2065 44.45 44.45 0.63 1-1/2 CB90055 300 1.94 1.94 1.83 40 2065 49.27 49.27 0.83 2 CB90066 300 2.25 2.25 3.10 50 2065 57.15 57,15 1.41 2-1/2 CB90077 300 2.70 2.70 4.80 65 2065 68.58 68.58 2.18 CAST IRON #0TITUS 90° REDUCED ELBOW • Approved By UL, ULC and FM at 300 psi • Cast Iron ASTM A 126 Class B. • NPT Thread per ANSI/ASME B1.20.1. IIIIIIIII • Dimension per ASME B16.4 • Marked with SPD • For current listing/approval details contact a Titus representative cOus ® APPROVED Nominal Size CODE Pressure Dimension Unit WT in/mm PSI/MPa A B LB/KGS 1x1/2 300 1.26 1.36 0.68 25x15 CB90031 2065 32.0 34.5 0.31 1x3/4 CB90032 300 1.37 1.45 0.77 25x20 2065 34.80 36.83 0.35 1-1/4x1/2 CB90041 300 1.34 1.53 0.97 32x15 2065 34.04 38.86 0.44 1-1/4x3/4 CB90042 300 1.45 1.62 1.08 32x20 2065 36.83 41.15 0.49 1-1/4x1 CB90043 300 1.58 1.67 1.19 32x25 2065 40.13 42.42 0.54 1-1/2x1/2 300 1.41 1.66 1.17 40x15 CB90051 2065 35.8 42.2 0.53 1-1/2x3/4 CB90052 300 1.52 1.75 1.30 40x20 2065 38.61 44.45 0.59 1-1/2x1 CB90053 300 1.65 1.80 1.43 40x25 2065 41.91 45.72 0.65 1-1/2x1/-1/4 300 1.82 1.88 1.65 40x32 CB90054 2065 46.23 47.75 0.75 24/2 CB90061 300 1.49 1.88 1.72 50x15 2065 37.85 47.75 0.78 2x3/4 CB90062 300 1.60 1.97 1.85 50x20 2065 40.6 50.0 0.84 2x1 CB90063 300 1.73 2.02 2.00 50x25 2065 43.94 51.31 0.91 2x1-1/4 CB90064 300 1.90 2.10 2.31 50x32 2065 48.26 53.34 1.05 2x1-1/2 CB90065 300 2.02 2.16 2.53 50x40 2065 51.31 54.86 1.15 CAST IRON ' TITUS 45° ELBOW • Approved By UL, ULC and FM at 300 psi • Cast Iron ASTM A 126 Class B. • NPT Thread per ANSI/ASME B1.20.1. • Dimension per ASME B16.4 • Marked with SPD • For current listing/approval details contact a Titus representative cOus ® APPROVE) Nominal Size CODE Pressure Dimension UnitWT in/mm PSI/MPa A B LB/KGS 1 CB45033 300 1.120 1.120 0.81 25 2065 28.448 28.448 0.37 1-1/4 CB45044 300 1.290 1.290 1.23 32 2065 32.766 32.766 0.56 1-1/2 CB45055 300 1.430 1.430 1.65 40 2065 36.322 36.322 0.75 2 CB45066 300 1.680 1.680 2.68 50 2065 42.672 42.672 1.22 CAST IRON TITUS REDUCED COUPLING • Approved By UL, ULC and FM at 300 psi „,; • Cast Iron ASTM A 126 Class B. • NPT Thread per ANSI/ASME B1.20.1. • Dimension per ASME B16.4 • Marked with SPD • For current listing/approval details contact a Titus representative cOus < APPROVED Nominal Size CODE Pressure Dimension Unit WT in/mm PSI/MPa A LB/KGS 1x1/2 CRC031 300 1.70 0.616 25x15 2065 43.18 0.28 1x3/4 CRC032 300 1.70 0.684 25x20 2065 43.18 0.311 CAST IRON TITUS CROSS • Approved By UL, ULC and FM at 300 psi • Cast Iron ASTM A 126 Class B. • NPT Thread per ANSI/ASME B1.20.1. • Dimension per ASME B16.4 • Marked with SPD • For current listing/approval details contact a Titus representative cOusAi> APPROVED Nominal Size W CODE Pressure Dimension Unit T in/mm PSI/MPa A B LB/KGS 1 CX033 300 1.50 1.50 1.60 25 2065 38.1 38.1 0.73 1-1/4 CX044 300 1.75 1.75 2.64 32 2065 44.45 44.45 1.20 1-1/2 CX055 300 1.94 1.94 2.99 40 2065 49.27 49.27 1.36 2 CX066 300 2.25 2.25 4.80 50 2065 57.15 57.15 2.18 CAST IRON €fTITUS { REDUCED CROSS • Approved By UL, ULC and FM at 300 psi • Cast Iron ASTM A 126 Class B. • NPT Thread per ANSI/ASME B1.20.1. • Dimension per ASME B16.4 • Marked with SPD • For current listing/approval details contact a Titus representative c Lus ® APPROVED Nominal Size CODE Pressure Dimension Unit WT in/mm PSI/MPa A B LB/KGS 1-1/4x1 300 1.58 1.67 1.89 32x25 CX043 2065 40.13 42.42 0.86 1-1/2x1 CX053 300 1.65 1.80 2.27 40x25 2065 41.91 45.72 1.03 2x1 CX063 300 1.73 2.02 2.99 50x25 2065 43.94 51.31 1.36 CAST IRON ZTITUS TEE __ • Approved By UL, ULC and FM at 300 psi 3, 111 • Cast Iron ASTM A 126 Class B. • NPT Thread per ANSI/ASME B1.20.1. ; _, / • Dimension per ASME B16.4 • Marked with SPD • For current listing/approval details contact a Titus representative cOus ® APPAOVEO Nominal Size CODE Pressure Dimension Unit WT in/mm PSI/MPa A B LB/KGS 1 CT333 300 1.50 1.50 1.25 25 2065 38.10 38.10 0.57 1-1/4 CT444 300 1.75 1.75 1.91 32 2065 44.45 44.45 0.87 1-1/2 CT555 300 1.94 1.94 2.55 40 2065 49.27 49.27 1.16 2 CT666 300 2.25 2.25 3.96 50 2065 57.15 57.15 1.80 2-1/2 CT777 300 2.70 2.70 6.38 65 2065 68.58 68.58 2.90 CAST IRON TITUS REDUCED TEE • Approved By UL, ULC and FM at 300 psi • Cast Iron ASTM A 126 Class B. • NPT Thread per ANSI/ASME B1.20.1. • Dimension per ASME B16.4 • Marked with SPD • For current listing/approval details contact a Titus representative cOus ® APPROVED Nominal Size W CODE Pressure Dimension Unit T Nominal Size CODE Pressure Dimension Unit WT in/mm PSI/MPa A B C LB/KGS in/mm PSI/MPa A B C LB/KGS 19/29 CT313 300 1.50 1.36 1.50 1.06 1-1/2x1-1/4x1-1/2 300 1.94 1.88 1.94 2.42 25.15.25 2065 38.10 34.54 38.10 0.48 40.32.40 CT545 2065 49.28 47.75 49.28 1.10 19/44 C7323 300 1.50 1.45 1.50 1.10 1-1/29-1/4x2 300 2.16 2.10 2.02 2.95 25.20.25 2065 38.10 36.83 38.10 0.50 40.32.50 CT546 2065 54.86 53.34 51.31 1.34 1x1x1/2 Ci331 300 1.26 1.26 1.36 0.97 1-1/2x1-1/2x1/2 300 1.41 1.41 1.66 1.80 25.2545 2065 32.00 32.00 34.54 0.44 40.40.15 CT551 2065 35.81 35.81 42.16 0.82 1x1x3/4 C1332 300 1.37 1.37 1.45 1.08 1-1/2x1-1/2x3/4 300 1.52 1.52 1.75 1.91 25.25x20 2065 34.80 34.80 36.83 0.49 40.40.20 CT552 2065 38.61 38.61 44.45 0.87 1x1x1-1/4 C7334 300 1.67 1.67 1.58 1.45 1-1/24-1/24 300 1.65 1.65 1.80 2.09 25.2592 2065 42.42 42.42 40.13 0.66 40.40.25 CT553 2065 41.91 41.91 45.72 0.95 144-1/2 CT335 300 1.80 1.80 1.65 1.72 1-1/29-1/241/4 300 1.82 1.82 1.88 2.42 25.25.40 2065 45.72 45.72 41.91 0.78 40.40.32 CT554 2065 46.23 46.23 47.75 1.10 1-1/44x1/2 CT431 300 1.34 1.26 1.53 1.19 14/2x1-1/2x2 300 2.16 2.16 2.02 2.99 32.25.15 2065 34.04 32.00 38.86 0.54 40.40.50 CT556 2065 54.86 54.86 51.31 1.36 1-1/4.14/4 300 1.45 1.37 1.62 1.34 C7432 24x2 300 2.25 2.02 2.25 3.21 32x25.20 2065 36.83 34.80 41.15 0.61 50.25.50 CT636 2065 57.15 51.31 57.15 1.46 1-1/444 C7433 300 1.58 1.50 1.67 1.45 24-1/42 300 2.25 2.10 2.25 3.50 322525 2065 40.13 38.10 42.42 0.66 50.32.50 R646 2065 57.15 53.34 57.15 1.59 1-1/449-1/4 300 1.75 1.67 1.75 1.78 CT434 24-1/24/2 300 1.49 1.41 1.88 2.27 32.2542 2065 44.45 42.42 44.45 0.81 50x40x15 CT651 2065 37.85 35.81 47.75 1.03 1-1/444-1/2 300 1.88 1.80 1.82 1.94 CT435 24-1/22/4 300 1.60 1.52 1.97 2.38 32.25x40 2065 47.75 45.72 46.23 0.88 50.40.20 CT652 2065 40.64 38.61 50.04 1.08 1-1/44-1/44/2 CT441 300 1.34 1.34 1.53 1.36 2x1-1/2x1 300 1.73 1.65 2.02 2.53 32.32.15 2065 34.04 34.04 38.86 0.62 50.40x25 CT653 2065 43.94 41.91 51.31 1.15 1-1/44-1/44/4 CT442 300 1.45 1.45 1.62 1.41 24-1/29-1/4 300 1.90 1.82 2.10 2.86 32.32.20 2065 36.83 36.83 41.15 0.64 50.40.32 CT654 2065 48.26 46.23 53.34 1.30 1-1/49-1/49 CT443 300 1.58 1.58 1.67 1.63 29-1/29-1/2 300 2.02 1.94 2.16 3.08 32.32.25 2065 40.13 40.13 42.42 0.74 50.40.40 CT655 2065 51.31 49.28 54.86 1.40 1-1/44-1/49-1/2 300 1.88 1.88 1.82 1.91 [T445 2x1-1/2x2 300 2.25 2.16 2.25 3.59 32x32)40 2065 47.75 47.75 46.23 0.87 50.40.50 CT656 2065 57.15 54.86 57.15 1.63 1-1/49-1/42 [T446 300 2.10 2.10 1.90 2.64 50x50x15 '.."'. 2065 37.85 37.85 47.75 1.17 32.32.50 2065 53.34 53.34 48.26 1.20 222/4 C7662 300 1.60 1.60 1.97 2.77 1-1/2.14/2 CT531 300 1.41 1.34 1.66 1.43 50.50.20 2065 40.64 40.64 50.04 1.26 40.25.15 2065 35.81 34.04 42.16 0.65 2x2x1 C7663 300 1.73 1.73 2.02 2.93 1-1/299/4 CT532 300 1.52 1.37 1.75 1.52 50.50.25 2065 43.94 43.94 51.31 1.33 40.25.20 2065 38.61 34.80 44.45 0.69 2x29-1/4 R664 300 1.90 1.90 2.10 3.21 1-1/24x1 300 1.65 1.50 1.80 1.78 50.50x32 2065 48.26 48.26 53.34 1.46 40x25.25 Ci533 2065 41.91 38.10 45.72 0.81 2x24-1/2 300 2.02 2.02 2.16 3.52 1-1/24.x1-1/4 300 1 82 1 67 1 88 1 98 S0.50.40 CT665 2065 51.31 51.31 54.86 1.60 1 143%5d312/2 Li S.34 R535 15 43 9t13 4E2% 417 bA% 22x2-1/2 CT667 300 2.60 2.60 2.39 5.06 40x25.40 2065 49.28 45.72 49.28 1.00 50.50.65 2065 66.04 66.04 60.71 2.30 1-1/29-1/49/2 C7541 300 1.41 1.34 1.66 1.58 40.32x15 2065 35.81 34.04 42.16 0.72 1-1/24-1/42/4 CT542 300 1.52 1.45 1.75 1.72 40.32.20 2065 38.61 36.83 44.45 0.78 1-1/24-1/42 C7543 300 1.65 1.58 1.80 1.91 40.32.25 2065 41.91 40.13 45.72 0.87 1-1/29 -1/4x1-1/4 Cr544 300 1.82 1.75 1.88 2.27 40.32.32 2065 46.23 44.45 47.75 1.03 CAST IRON -OTITUS • PLUG • Approved By UL, ULC and FM at 300 psi • Cast Iron ASTM A 126 Class B. • NPT Thread per ANSI/ASME B1.20.1. • Dimension per ASME B16.4 • Marked with SPD • For current listing/approval details contact a Titus representative cOus ® APPROVE° Nominal Size CODE Pressure Dimension Unit WT in/mm PSI/MPa A LB/KGS 1/2 CPL001 300 0.94 0.10 15 2065 23.88 0.05 3/4 CPL002 300 1.07 0.18 20 2065 27.18 0.08 1 CPL003 300 1.25 0.29 25 2065 31.75 0.13 1-1/4 CPL004 300 1.36 0.46 32 2065 34.54 0.21 1-1/2 CPL005 300 1.45 0.64 40 2065 36.83 0.29 2 CPL006 300 1.56 1.08 50 2065 39.62 0.49 Y • kNNIN $ E.` HfW{/A.> k 4{&#C!6'R84mim fistan I8�{3 x dlfdBfsuntraunsure °I; TITUS www . titusindustrial . com • TITUS • TITUS DUCTILE IRON THREADED FITTINGS FIRE PROTECTION TECHNICAL BULLETINS !0fNP4M ft (IIifPiPtHYS UMMItO IX4C N.ItO8B.19t4INMi6Ntt'1011fiiiiS11N111it4CIt4NNFEtf!ritttpl#Mk86H AMOMINI•Str.114114 Itit$tMtPNl9Htt1811XIMP8 PHild1 tadllii litiNitlt1.lt l'1'Nt4t.0210 0.1Jt Cf r v. •,,,.,.t ,i::.; 4d F1f3E E t3 , www . titusindustrial . com TABLE OF CONTENTS -OTITUS DUCTILE IRON THREADED FITTINGS 3. TITUS DUCTILE IRON FITTINGS 4. TITUS DUCTILE IRON FITTINGS - CONT. 5. TITUS DUCTILE IRON FITTINGS - CONT. 6. TITUS DUCTILE IRON FITTINGS - CONT. DUCTILE IRON THREADED FITTINGS fTITUS TITUS DUCTILE IRON FITTINGS • Fittings are manufactured in accordance with ASME B16.3 • Bushings and Plugs are manufactured in accordance with ASME B16.4 • Unions are manufactured in accordance with ASME B16.39 • Threads NPT per ASME B1.20.1 • �'. • Available in 1/2" - 2 1/2" • Fittings are 100% air tested • Marked with BIS • For current listing/approval details contact a Titus representative cOu s 1 APPROVED . . DUCTILE IRON THREADED FITTINGS 2flTUS TITUS DUCTILE IRON FITTINGS - CONTINUED ` A FIG.ADBL90 ELBOW 90° '"....41,I , INNER BOX MASTER Ctn. 512E(INCH) A(in) B(in) C(in) WEIGHT(LBS.) Remarks . PCS/BOX PCS/Ctn. �♦ ♦ 1/2 1.17 0 25 SO .00 UL,FM ���.,( 1 I) A 1 1.50 0.57 20 60 UL,FM /� 1 id- 11/4 1.75 0.97 20 40 UL,FM 11/2 1.94 1.43 15 30 UL,FM . 2.0'. 1.93 8 16 UL,FM 21/2 2.,, 2,89 12 12 UL,FM B FIG.ADBRL REDUCING ELBOWS ir__It INNER BOX MASTER Ctn. �5���� SIZE(INCH) A(in) B(in) C(in) WEIGHT(LBS.) Remarks •., PCS/BOX PCS/Ctn. ♦♦♦ 1 X 1/2 1.26 1.40 0.43 25 100 UL,P.,.. ��, 1X3/4 1.37 1.45 0.56 50 100 IL,fM 12%P.- / A 11/4X1/2 1.34 1.53 0.61 20 80 IL,FM .Alin 11/4 X 3/4 1.45 1.62 0.71 15 60 UL,FM I 11/4 x 1 1.58 1.67 0.73 10 40 UL,FM 11/2 X 1/2 1.52 1.75 0.71 15 60 UL,FM 11/2 X 3/4 1.52 1.75 1.01 10 40 UL,FM 11/261 1.65 1.80 0.92 10 40 UL,FM 11/2 X 11/4 1.82 1.88 1.04 15 30 UL,FM 2X3/4 1.60 1.97 1.10 9 36 UL,FM 2 X 1 1.73 2.02 1.22 14 28 UL,FM 2 X 11/4 1.90 2 10 1.48 10 20 UL,FM 2 X 11/2 2.02 2 16 156 10 20 UL,FM FIG.ADBL45 ELBOW 45° /,� INNER BOX MASTER Ctn. X SIZE(INCH) A(in) B(in) C(in) WEIGHT(LBS.) Remarks ♦. PCS/BOX PCS/Ctn, �/ ��A 1 1.12 0.55 20 60 UL,FM 11/4 1.29 0.85 20 40 UL,FM MillA/II I A 1 1/2 1 43 1.12 10 30 UL,FM I 2 168 1.54 12 24 UL,FM FIG.ADBT TEES 1111 `'�I``i A INNER BOX MASTER Ctn. SIZE(INCH) A(4 B(in) C(in) WEIGHT(LBS.) PCS/BOX PCS/Ctn. 1 1.,0 0.83 20 40 UL,FM Remarks .„__ i 1 1/4 1 1.30 14 28 UL,FM t ;:I A 11/2 i 04 1.68 12 24 UL,FM �T�. 2 2.79 8 16 UL,FM UL C US l APPROVED DUCTILE IRON THREADED FITTINGS ? TITUS TITUS DUCTILE IRON FITTINGS - CONTINUED FIG.ABGRT REDUCING TEES INNER BOX MASTER Ctn. 512E(INCH) A(in) B(in) C(in) WEIGHT(LBS.) Remarks pu/BOX PCS/Ctn. 3/433/4 31/2 120 1 20 1.22 052 20 80 UL FM 3/4 03/401 145 1,45 1 37 063 40 61 UL,FM • `111111f; 3/4 X 3/4 X 11/4 1.62 1 62 1.45 0.82 20 60 UL,FM iI �V.� I 1 X 1/2 x 1/2 1.1 X. 1.12 140 0.48 20 80 UL FM a`4 I 1%1/2 X 3/4 137 1.22 1.45 0.54 20 80 UL.FM }--�I 1 X 1/2 X 1 1.50 1.22 1.45 0.69 15 60 UL.FM -i� I 1X3/4X 1/2 1.26 1.20 1.40 0.58 20 80 UL FM \`� ♦\ ` `� 183/4X3/4 1.37 1.31 1.44 0.66 15 60 UL,FM A-' 1%3/4X1 1.50 1.45 1.50 0.75 30 60 UL,FM 1 X 1 X 1/2 1.26 1.26 1.40 0.64 15 60 UL,FM 10103/4 1.37 1.37 1.45 0.70 12 48 UL,FM 110111' 101611/4 1.67 1.67 158 1.09 11 34 UL,FM C �� US 101811/2 1.80 1.80 1.65 1.22 9 36 UL,FM APPROVED 1 X1X2 2.02 2.02 1.93 I.54 12 24 UL,FM 11/4 X 1/2 X 1 1.58 1.36 1.67 0.88 20 40 UL FM 11/4 X 1/2 X 11,/4 1.75 1.53 1.75 1.03 20 40 UL,FM 11/4 X 3/4 X 3/4 145 1.31 1 62 0.81 10 40 UL,FM 11/4 X 3/4 X 1 1,58 1.45 1.67 0.94 10 40 UL FM 11/403/4X 11/4 1.75 1.62 175 1,09 20 40 UL,FM 11/40141/2 134 1.26 1.53 0.83 20 40 UL,FM 11/40103/4 145 1.37 1.62 0.87 20 40 UL,FM 11/4 X 1 X 1 158 1 50 1.67 1.01 20 40 UL FM 11/4 x 1 x 11/4 1,75 1 6' 1,75 1.16 15 30 UL,FM 11/4 x 1 x 11/2 1,88 1.88 1.82 UL FM 11/4 x 11/4 x 1/2 1.34 1.34 1.53 0.87 20 40 UL,FM 11/4 x 11/4 x 3/4 1.45 1.45 1.62 0.97 20 40 UL,FM 11/4 x 11/431 1.58 1.58 1.67 1.06 20 40 UL,FM 11/4 x 11/4 x 11/2 1,88 1.88 1.82 2.13 12 24 UL,FM 11/4x 11/442 2,10 2.10 1.90 1.83 12 24 UL FM 11/2 x 1/2 z 11/2 1.94 1.66 1.94 1.46 12 24 UL,FM 11/2 x 3/4 x 11/2 1,94 1.75 1,94 1.44 12 24 UL,FM 11/28151 1.65 1.50 1.80 1.21 15 30 UL,FM 11/2 x 1 z 11/4 1,82 1.67 1,88 1.33 12 24 UL,FM 11/2 x 1 x 11/2 1.94 1.80 1.94 1.58 12 24 UL,FM 11/2 x 11/4 x 1/2 1.41 1.34 1.66 1.01 12 24 UL FM 11/2 x 11/4 x 3/4 1.52 1.43 1.75 1.10 :2 24 UL,FM 11/2 x 11/4 x 1 165 1.58 1,80 1.25 .. :'I UL,FM 11/2 x 11/4 x 11/4 182 1.75 1.88 1.41 12 24 UL,FM 11/2 x 11/4 x 11/2 194 1.88 1.94 1.54 12 24 UL,FM 11/2x11/4 x2 2,16 2.16 2.02 2.02 8 16 UL FM 11/2 x 11/2 x 1/2 141 1.41 1.66 1.03 18 36 UL,FM 11/2 x 11/2 x 3/4 1.52 1.52 1.75 1.28 15 30 UL FM 11/2 z 11/2 x 1 1 65 1.65 1.80 1.40 10 30 UL,FM 11/2 x 11/2 x 11/4 1.82 1.82 1.88 1.51 12 24 UL,FM 11/2 511/2x2 2,16 2.16 2.02 2.05 8 16 UL,FM 281/282 2.25 1.88 2.25 2.20 8 16 UL FM 283/482 2.25 1.97 2.25 1.62 8 16 UL,FM 281811/2 2,02 1.80 2.16 1.89 10 20 UL,FM 2 x 1 4 2 225 2.02 2-25 2.20 8 11 UL FM 2 x11/4x11/4 190 1.75 2.10 1.76 8 I5. UL,FM 2 x 11/4 811/2 2,02 1,88 2,16 2.21 8 10 UL FM 2811/482 2,25 2.10 2.25 2,20 8 16 UL,FM 2 x 11/2 x 1/2 1.73 1.65 2,02 1.70 30 20 UL FM 2 x 11/2 81 1.73 1.65 2,02 1.60 10 20 UL FM 2411/2811/4 190 1.82 2.10 1.76 8 16 UL,FM 2x11/2x11/2 2('2 1.94 2.16 190 8 1t UL,FM 2811/2 42 2.25 2,16 2.25 188 8 16 UL,FM 28281/2 149 1.49 1.88 171 10 20 UL,FM 2 x 2 x 3/4 160 1.60 1.97 1 70 10 20 UL,FM 28281 1.73 1.73 2.02 1.80 10 20 UL,FM 282811/4 1.90 1.90 2.10 2.05 8 16 UL,FM 282x11/2 2.02 2_.. 2.09 2 UL FM DUCTILE IRON THREADED FITTINGS At 'T S TITUS DUCTILE IRON FITTINGS - CONTINUED FIG.ADDS COUPLING INN,B BOX M to CIt Ctn aIXS I)HTTH Al(I.,) A(in) s(l) WLICttl riot. _ Xamoaka P1aNX r€a/�LR, - 1 f,7 0.47 15 1(NI L I.FM 11/4 103 0,66 16 64 UL,FM 11/2 2.15 0.94 18 36 UL FM 2 2.53 1.49 12 24 UL,FM OWO; --C. FIG.ADBRS REDUCING COUPLING A INNER BOX MASTER Ctn. /rAlikSIZE(INCH) A(in) B(in) C(in) WEIGHT(LBS.) P[5/80% PCS/Can. Remarks �a 0x'1 2 14 0.76 GO 180 U(,FM .;-...--'16 54 Is!,,2 .i 0.37 30 120 Hexagon small end,U11 M V 1x3/4 0.42 25 100 I lexaIon small end,UL,FM 11/4 x 1/2 0.57 25 75 UI,FM 11/4 x 3/4 206 0.60 25 75 UL,FM 11/481 2.06 062 15 60 UL,FM FIG.ADBBU BUSHINGS EI g 1 INNER BOX MASTER Ctn. SIZE(INCH) A(in) B(in) C(in) WEIGHT(LBS.) PCS/BOX PCS/Can. Remarks A Itl�l A 3/4 x 1/2 1.2, 0 14 75 300 outside tread,UL.FM v 1 x 1/2 1.14 0.28 50 200 outside head,UL,FM 183/4 1.14 0.19 50 200 outside head.UL.FM 11/4 a 3/4 1.30 0.37 30 120 outside head,UL,rM 11/4 x 1 1.30 0.30 30 120 outside head,UL,FM 11/2 x 1 1.34 0.52 25 75 outside head,Mu FM 11/2 x 11/4 1.34 0.37 25 75 outside head,UL,FM 281/2 1,50 9.90 20 60 lside head,L11.FM 2a3/4 667 34 FIG.ADBP PLUGS I11' . I 512E INCH) A(i IX MASTER CtnB(in) C(In) WEIG HT(LBS.) Remeks(I A 111 -.. 0 I0II-�w,41 L.IM 3/4 1.07 016 __ 420 hnllpw.ill.FM 1 75 0.26 20 240 hollow,60,FM 11/1 136 0.31 40 120 hollow,UL.FM 11/2 1 42 0.55 30 90 hollow,UL FM 2 1.57 0.65 20 60 hollow,UL,FM A A FIG.ADBCR CROSS D'a1i� INNER BOX MASTER Ctn. `00 I '�-i IA SIZE(INCH) A(in) B(In) C(in) WEIGHT(LBS.) Remarks PCS/BOX PCS/Ctn. 1 lLt� 698 15 30 11,.fh 11/4 1.55 10 20 II,FM 11/2 2,34 1.84 B 16 UL,FM g1 G ��N1G --x 3.26 5 10 UL,FM FIG.ADBC CAP Mb) SIZE(INCH) A(in) B(In) C(in) WEIGHT(LEG) INNER BOX MASTER Ctn. Remarks PCS/BOX PCS/Can. Al 16 0.32 00 M 1 1 (` 11/4 1.28 0.49 20 B0 UL FM 11/2 1.33 0.67 18 54 UL FM O 2 145 0.88 12 36 UL,FM IYFnVaW 1 TITUS li { if www . titusindustrial corn ,f :k. i :f iG ']{ .,-,•- • 0 Schedule 10 and Schedule 40 FM Approved and UL Listed Sprinkler Pipe Bull Moose Tube Company is a recognized producer Bull Moose Tube's Sch. 10 and Sch. 40 pipes are of quality pipe products. Our Schedule 10 and made to ASTM A135 and ASTM A795. These Schedule 40 are FM Approved and UL Listed (for U.S. products are typically supplied with our protective and Canada), even though these products do not coating but can be supplied without the coating so require separate approvals and listings. Bull Moose they can be hot-dip galvanized to meet FM Tube made the decision to have them approved and requirements for use in dry systems in accordance listed for your peace of mind. Our Sch. 10 and Sch. 40 with the zinc coating specifications of ASTM A795 or have been through the same rigorous testing as our ASTM A53. All Schedule 10 and Schedule 40 pipe other fine pipe products. has a pressure rating of 300 PSI. Schedule 10 Pipe Nominal Pipe Size (in) Nominal O.D. (in) Nominal I.D. (in) Weight/Ft Bundle Size 1 1.315 1.097 1.41 lbs/ft 91 1 1/4 1.660 1.442 1.81 lbs/ft 61 1 1/2 1.900 1.682 2.09 lbs/ft 61 2 2.375 2.157 2.64 lbs/ft 37 2 1/2 2.875 2.635 3.53 lbs/ft 30 3 3.500 3.260 4.34 lbs/ft 19 4 4.500 4.260 5.62 lbs/ft 19 Schedule 40 Pipe Nominal Pipe Size (in) Nominal O.D. (in) Nominal I.D. (in) Weight/Ft Bundle Size 1 1.315 1.049 1.68 lbs/ft 70 1 1/4 1.660 1.380 2.27 lbs/ft 51 1 1/2 1.900 1.610 2.72 lbs/ft 44 2 2.375 2.067 3.66 lbs/ft 30 2 1/2 2.875 2.468 5.80 lbs/ft 30 3 3.500 3.068 7.58 lbs/ft 19 4 4.500 4.026 10.80 lbs/ft 19 PIPE PREPARATION For proper operation,all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket,pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint,scale,dirt,chips,grease,and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly,causing leakage. Also,check the manufacturer's instructions for the specific fitting used. 1819 Clarkson Road For additional information, C 0� uSA Chesterfield,MO 63017 contact your salesperson U P'U, MOOSE TIDE COMPiANY (800)325-4467 today at(800)325-4467 or LISTED '- FAX:(636)537-2645 (636)537-2600 in the USA, www.bullmoosetube.com or from Canada AL A O company e-mail:sales a bullmoosetube.com call(800)882-4666 11> APPROVED All information contained herein is accurate as known at the time of publication. Bull Moose Tube reserves the right to change product specifications without notice and without incurring obligation. 12/09