Loading...
Plans (98) M EC2021 -00875 OFFICE COPY RECEIVE[ 0 E OCT 2 7 201! U w m > CITY OF TIGARD F_ L *Ife nce sBUILDING DIVISION - a _ X00 U Ea, Q O e N N 010 H E A L T H � W VALIDITY OF PERMIT i Y THE ISSUANCE OF A PERMIT d IM TENANT IMPROVEMENT DATA D ON SHALL oW DOCUMENTS AND OTHER ~ DATA SHALL NOT PREVEf IT 2 THE CODE OFFICIAL FROM REQUIRING THE CORRECTION = 9600 SW OAK ST, ST 500 OF ERRORS. OSSC 105.4 v LL TIGARD OR 97223 GENERAL NOTES CODE SUMMARY PROJECT SUMMARY • GENERAL CONTRACTOR TO VERIFY LEASE DIMENSIONS,EXISTING DIMENSIONS, EXISTING STRUCTURAL ELEMENTS, AND CEILING CRITERIA REQUIREMENTS CODE REFERENCE THIS YORK COH515TS OF THE INTERIOR ALTERATIONS FOR A BJ511 IN AN EASTIN6 VACANT TENANT SPACE ON THE FIVE FLOOR OF s••r1 r...vse+si Aea•�•eb. HEIGHT CLEARANCES,ETC. AND REPORT TO ARCHITECT ANY INCONSISTENCY PRIOR TO START OF CONSTRUCTION. - - - -_-- AN EXI5nN6 FIVE-STORY WILDING. THE WORK INCLUDES COMBININS EXISTING TENANT SPACES 500 AND 520. xnvwe•1e e1•rrlw r•pr•n H CTION 11-B (FULLY 5PRINKLERED) IBC SEC °��•eti ns•1��°reestr•t • GENERAL CONTRACTOR TO COORDINATE ANY WORK IN TENANT SPADE BELOW,ABOVE AND OR TYPE OF CONSTRU ADJACENT WITH THAT TENANT TION 601 c��wM1•s. �Ye A>d4•f. Tb 1w THE WORK INCLUDES: THE LIMITED DEMOLITION OF INTERIOR NON-LOAD BEARING PARTITION WALLS;THE C.ONSTRUGTION OF NEW •t�•e••M�+ue•e es1•hweee AND LANDLORD. WORK TO TAKE PLACE OFF HOURS AND INCLUDE SECURITY AS REQUIRED BY TENANT AND OWNER NUMBER OF FLOORS (EXISTING) 5 FLOORS INTERIOR NON-LOAD BEARING PARTITION WALLS;THE CONSTRUCTION AND INSTALLATION OF NEW INTERIOR FINISHES INCLUDING • DIMENSIONS NOTED (WIDTH ! HEIGHT) ARE TO BE MAINTAINED EXCEPT WEEN NOTED BY A r/- DIMENSION. LAY-IN CEILINGS AND LED LIGHT FIXTURES;THE MODIFICATION OF EXISTING ELECTRICAL, MECHANICAL, AND PLUMBING SYSTEMS; airAil•��ruw ren•,Arew•et LOCATION OF WORK 5TH FLOOR AND ALL NECESSARY AND PERTINENT ITEMS AS DIRECTED AND SPECIFIED BY THE TENANT. at a.rt•er•F. • DO NOT SCALE ORAWIN65. REQUEST CLARIFICATION FROM THE ARCHITECT TO RESOLVE DISCREPANCIES OR TO SUPPLY WILDING HEIGHT (EXISTING) / NO CHANGE(PROPOSED) ADDITIONAL INFORMATION. • GENERAL CONTRACTOR TO CLARIFY ANY INCONSISTENCIES WITHIN THE CONSTRUCTION DOCUMENTS WITH THE ARCHITECT PRIOR 115E AND OCCUPANCY GROUP B - BUSINESS(1'ROFE5510NAL OFFICE) IBC SECTION 302 304 DRAWING INDEX / TO STARTING CONSTRUCTION. REVISIONS - - - - - - - - - • GENERAL CONTRACTOR 15 RESPONSIBLE TO VERIFY THAT THE MECHANICAL AND ELECTRICAL CONTRACTOR 15 SUPPLYING, AND GVR COVER SHEET INSTALLING THE SPECIFIED ITEMS. GENERAL CONTRACTOR IS TO CLARIFY ANY INCONSISTENCY SETNEEN ARCHITECTURAL AREA AND OCCUPANT LOAD CALCULATIONS 4032 SQ FT(ExSTIN6) IBC 1004.12 / 1004.2 ARCHITECTURAL PLAN AND MECHANICAL AND ELECTRICAL PLANS PRIOR TO ANY INSTALLATION. OFFICES e, 100 GROSS 50 FT PER OCZUPANT= 40 OCCUPANTS IBC,SECTION 506 - -- L51.0 LIFE SAFETY • GENERAL CONTRACTOR AND ALL 50 TRADES TO MAKE EVERY EFFORT TO PURCHASE MATERIALS FROM LOCALLY TOTAL SQUARE FEET/TOTAL OCCUPANTS 4032 5F/40 OCCUPANTS IBC TABLE 1004.12 DID DEMOLITION FLOOR PLAN EXTRACTED AND MANUFACTURED SOURCES(WITHIN 500 MILE RADIUS). DI.1 DEMOLITION CEILIN6 PLAN • ALL WOOD PRODUCTS USED FOR FRAMING,ETC., THAT ARE NOT CLASSIFIED AS 'INTERIOR FINISH MATERIALS' A64ORDIN6 TO AIA FLOOR PLAN CODE SHALL BE FIRE PRESSURE TREATED LUMBER. EXITS REQUIRED/EXITS PROVIDED I (REQUIRED) /2 (PROVIDED) IBC TABLE 10063.1 AH CEILING PLAN • PROVIDE FIRE BLOCKING AND DRAFT STOPPING AS SPECIFIED IN CODE CONGEALED WALL SPACES, IN CONGEALED SPACES - _-- -- - ---- __EGRESS REQUIRED' B'REQUIRED IBC SECTION 100532 A2.0 FINISH PLAN OF STUD WALLS AND PARTITIONS, INCLUDING FURRED OR STUDDED OFF SPADES OF MASONRY OR CONCRETE WALL5, AT THE CEILING, FLOOR,OR ROOF LEVELS. 40 GGGUPANTS x 20' INGFES PER OGCUPANi = .__ __- __ _.. _ _- A3.0 ENLARGED PLANS 1 INT. ELEVATIONS/ DETAILS • PENETRATION THRU EGRESS WIDTH PROVIDED RATED WALLS AND FLOORS SHALL BE SEALED WITH A MATERIAL CAPABLE OF PREVENTING THE PASSAGE (2) DOORS x 34` EACH 680 PROVIDED A3.1 WALL TYPES/DETAILS OF FLAMES AND HOT GASES WHEN SUBJECT TO THE REQUIREMENTS OF THE TEST STANDARD SPECIFIED FOR FIRE STOPS A3.2 5GHEDULE5 A5TM-E-614. A4O ACCE55113ILITY • LIGHT FIXTURES TO BE SUPPORTED INDEPENDENTLY OF SUSPENDED CEILINGS SHALL BE SUPPORTED WITHIN 6" OF EACH MAXIMUM TRAVEL DISTANCE: 9OO'-0' MAXIMUM IBC TABLE 10172 A5,0 SPECIFICATIONS CORNER OF FIXTURE IN ACCORDANCE WITH A5TM 0-656 76. REFER TO DETAILS IN PLANS. --- ----- MAXIMUM COMMON PATH DISTANCE: 100'-0' MAXIMUM IBc TABLE 10062.1 A5.1 SPECIFICATIONS CONT. • EXIT AND EMERGENCY LIGHTING - EXIT AND EMERGENCY LI6HTIN6 SHALL BE ADEQUATE HOWEVER THE CITY RESERVES THE RIGHT TO MAKE FINAL DETERMINATION ON 517E. A5.2 I 5PECIFICATION5 DONT. • INTERIOR FINISH - CERTIFICATION OF "FIRE RATING' SHALL BE SUBMITTED TO THE WILDING DEPARTMENT BY THE TENANT FOR PLUMBING CALCULATIONS IBC TABLE 2902.1 MECNAHICAL S PLLIMM CARPETING AND OTHER INTERIOR FINISH MATERIAL REQUIRED BY CODE PRIOR TO THE ISSUANCE OF OCCUPANCY PERMIT. MIO MECHANICAL LEGEND,SCHEDULES 9 DETAILS B: TOILETS - I PER 25/LAV5 - I Phi 40 • COMPLY WITH SPECIAL WORKIN6 CONDITIONS RELATING TO THE PROJECT, I14GLUDIN6 BUT NOT LIMITED TO REQUIREMENTS FOR MDI.O MECHANICAL DEMO PLAN TEMPORARY PROTECTION, TRASH MANAGEMENT,NOISE, LI6HT,DUST AND POLLUTION CONTROL, AND LIMITATIONS ON HORKIN6 TOILETS : 40/25 s Ib LAV5 : 40/40 s 1 (SEE NOTE I) REQUIRED. HOURS 2 TOILETS/I LAV M2.0 MECHANICAL FLOOR PLAN ACTUAL FIXTURES PROVIDED (SEE NOTE 2) M: 2 TOILET/2 LAV/2 URINAL F: 5 TOILET/2 LAV MPLO MECHANICAL SPECIFICATIONS • ALL 50MITTAL5 SHALL BE SENT TO GBRE PROJECT MANAGER FOR PROCESSING. DO NOT INCLUDE ARCHITECT ON INVITATIONS FOR PROGORE OR SIMILAR TRACK'NG SYSTEMS MP2.0 MECHANICAL SPECIFICATIONS CONT CODE NOTES APPLICABLE CODES PILO PLUMeIN6 SCHEDULES, DETAILS 4 NOTES • YYNEN SUBMITTING A SUBSTITUTION, A SEPARATE PACKAGE MUST BE CREATED WITH A REQUEST TO SUBSTITUTE COVER LETTER. THE SUBMITTAL SHALL INCLUDE THE ORIGINAL DESIGN CUTS SHEETS/SPECIFICATIONS AND THE PROP05ED SUBSTITUTION CUT I. Pil-15IN 6 FACILITIES GAICLLATED AS B-BUSINESS/FROFES60N&Gt'FICE. OCCUPANCY USE 209 OR5604 MEOKN IGAL 5`ECIALTY COLE P2.0 PLUMIBIN6 PLAN SHEETS H16H-Ll6HTED TO 5HOW EQUAL. THE REQUEST MUST BE INDEPENDENT FROM OTHER SUBMITTALS. FAILURE TO GROIP IS DECIDED BY TENANT BUSINESS OPERATION Y+ERE FROFE56ORAL CO.W50-INS OFFICE 20T ORIESCN Rl#,BIN6 5PEGIA LTY COC',£ p�,�,s� SEPARATE OR SHOW AS A SUBSTITUTION WILL BE REJECTED. IS THE PRIMARY OPERATION t NICE 2019 OREGON FIRE CODE -- 'C - 2. RLF61N6 FIXTUES ARE PRGVIGED IN THE CIF--Y.N`.,PAGE ✓'ffiTLR204 OREGON ELELTRIC SPECIALTY GORE INF'A 70) EIA ELECTRICAL LEGEND,SGHEDU-E5 4 DETAILS 4 SUITES. _HARE77 FIXES 2019 ORE604 5TR r-TURAL 5=I5C4ALTY CODE ARE EXISTING AND NOT TO W CHAN ED MYTH THIS TENANT IMRROvH-HNT. 209 OREGON ZERO DE RGY READ(COM IERCIAL CODE ELI ELECTRICAL DETAILS ANY AMGD ALL APPLICABLE LOCAL,STATE,REGIONAL 4 EDLO DEMOLITION PLAN FEVER&CODES AND RCSULATONE, E2.0 LIGHTING PLAN ES.0 POWER PLAN E4.0 ELECTRICAL SPECIFICATIONS E4.1 I ELECTRICAL SPECIFICATIONS CONT. AND 15 VICINITY MAP SITE MAP CONTACTS NOT ANDN65ILED BYViTATHE T�HTE T) ARCHITECT MECHANICAL ENGINEER ELECTRICAL ENGINEER ONYX CREATIVE BLUE STREAK CONSULT:NG BLUE STREAK CONSULTING 1 - 25001 EMERY ROAD,SUITE 400 25001 EMERY ROAD,SUITE 420 25001 EMERY ROAD,SUITE 420 CLEVELAND,OH 44125 CLEVELAND,OH 44128 CLEVELAND,OH 44128 CONTACT: STACEY 0'60NN(see above) CONTACT: TONY DISTEFANO CONTACT. TONY DISTEFANO PN 216-223-3226 PH 216-223-3281 PH 216-223-3281 �. t. E. sogurr®oryxcreative.com E: tdbtefano®bluestreak-cornulting.com E: tdlstefanoobluestreak-conwlting.com AdL [• TENANT REPRESENTATIVE MUNICIPALITY LU GBRE RETAIL PROJECT MANAGEMENT CITY OF TIGARD, OREGON CLEVELAND,OH 13125 5W HALL BLVD., 4 g, CONTACT: JIM HITT TIGARD,OR 97223 ,A N PH: 216--55.4480 PH: 503-639-41'11 v' E: Jimrvitt9cbre.com W W Ir T s[ W tCN c REQUIRED VENDOR = a o 0 ARCHITECTURAL CEILINGS FLOORING LIGHT FIXTURES / DIMMERS z ARMSTRONG CEILIN65 SHAW CONTRACT MARS ELECTRIC SUPPLY Q DEBORAH PICKENS TAMMY JACK50N AT THE LIFE5TANGE CONTACT: PHIL HARRELL I7 PH: 480-695-9053 CUSTOMER SERVICE HOTLINE: PH: 216-410-3592 ~ _ E: dlpickene®armstrongceilkxp PH: 844-752-"1429 E: phorrall®mars-elxtric.com E: I Hestmceeshowhccom .. Ptgeot Moa tBE76 OFFICE DOOR SIGNS WALL BASE ACCENT LIGHTING ro .oMkeslgworrlpaycan TARKETT RBW Q� ROUND ROOM tRi 51GN5 Wf. CK -ADA BRAILLE RECERBIGE NPNM•09-72 E: sales®ronsam ply yA 4A DIAMETER 07mim tRwMxi1 MILLWORK THE LEIDEN CABINET COMPANY,LLC(2365 - g EDSON BLVD,THIN513UR6,OH 4408-) MARK MITTAKER- • , OFFICE COPY' - 234-1504-8155 AKER9LEIDENGOMPANY.GOM- CITY OF TIGARDs.. ".< REVI ED FOR CODE COMPLIANCE APP � [J I OTC: [ J a Wyk; .^` - ,:;,W„ " renuit : YY-)t--e- moa y AddresRl; Ca l � Oc. 1< N L I FESTANCE HEALTH N Suite 61600 SW OAK ST FIFTH FLOOR . By:�� Date: IL L2 4 TIOARD OR q-7223 V V^ \ , �U w�0 I°"• COVER SHEET %�d EXIT WIDTH CALCULATIONS EMERGENCY LUMINAIRE SCHEDULEw EXIT NO. EXIT SIZE CLEAR WDTH �.WDIH FACTOR �.CAPACITY PROVIDED �vcuwml rn o I❑ 36' 34" 0.20' �'/0.20•) = Il0 LOAD CAPACITY U TYPE LAMP WATTAGE VOLTAGE DRIVER DESCRIPTION CATALOG NUMBER T M 36' 34" 0.20" (34' PIO LOAD CAPACITY = ¢ o `o X10 O SELF CONTAINED UNIVERSAL MOUNT LED EXIT 516N WITH DUAL LITHONIA U `m No A LED 3 UNV _ HEADS,OMITENAL ARR M AS5 H HOUSING, QUANTITY OF FADES AND LHGM-LED-R-SD OCCUPANCY LOAD CALCULATIONS DIRECTIONAL ARROWS A5 SHOWV ON PLANS,SELF DIAGNOSTICS Q o o N SUITE SELF CONTAINED UNIVERSAL MOUNT LED EXIT SIGN,WHITE LITHONIA - -- - � NAME AREA !SF) 1�CLA%IF. SF/OCGUPPNf TOTAL o � 520 t 500 OFFICE /5U'PPORT N v N TFERMOPLASTiG HOUSING,QUANTITY OF FADES AND DIRECTIONAL LGM-SW-3-120/2'7"!-ELN-SD 4032 50 FT BUSINESS SEE CODE SUMMARY 1% W X2 LED 2 UNV - ARROWS AS SHOT N ON PLANS,SELF DIA6NOSTIG5 ON CVR OCCUPANCY NOTES' W he _ _. _ _— —_—_. L TOTAL SQUARE FOOTAGE IS LINKED TO THE 68055 AREA OF THE TENANT = SELF CONTAINED WALL MOUNTED EFIERGENCY LI6HTIN6 UNIT WTH LITHONIA SPACE FOR OCCUPANCY &ROUP B - BUSINESS. IL IIx LED 2 UNV - DUAL HEADS,WHITE THERMOPLASTIC HOUSING,SELF DIA6NOSTICS, ELM2L-WOLT-SMTEM O W C` GENERAL NOTES w I. ANY AND ALL POINTS OF EGRESS WITHIN THE SPACE ARE TO NOT (i ILL. EXCEED THE VALUES OF TRAVEL D15TANCE REQUIRED BY CODE: 300'-0" MAX FOR OCCUPANCY GROUP B, FULLY-SPRINKLERED 2. INSTALL FIRE EXTINGUISHER5 IN CABINETS AS DIRECTED ON AI.O. FIRE EXTINGUI5HE1;Z5 TO BE TYPE ABG, 10 POUNDS, WITH 2 DEVICES MINIMUM. FINAL GUANT17Y AND LOCATIONS TO BE COORDINATED IN FIELD W/ FIRE MARSHALL AND GBRE PROJECT MANAGER. REFER AI.O FOR CONTENT. 3. REFER TO CODE SUMMARY ON COVER SHEET FOR ADDITIONAL INFORMATION Ue..l ell! of soFYFn we given r bFblrwb OI momm W,bee 111 eFF11FFI1FF.M le.e11 s rcOeFbrtlrw �F. rretfee er w bIF deep O these,a IFwFFFFY br WFFFM eYrr..IW FFeWb.eleel YeFe IIfFIF Y Nrb11e pe1W e.m FeFl NW belse e.eet el CYbteFeer F. rFl .Melwwl I 1 mr r 0101 OFFICE z ORICE F OniCF a a1.10t. I I , r'FRVL DISC ---I ❑ c0 I p Q _JII E. fffi N O ID C) (( 17--T - wuTM° i ,m I 1f7 ,i _ .- !� 80011 iui r, PORTABLE F.E SUITE EORE55 ccFrlvl wea I MAIN ENTRANCE s H' W W _ _ ® 148-4" TRAVEL DISTANCE -_ - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -- — J z UU I5,J7= TO EX'T STAIR ----- - cm _ < W F N —'� - Fcm .E. - r--, —.—.—___� J = Y O^f cr a < %__ i i Roar Vii, caaeawo ,� 0 O I{ \ fr zai � FYI ♦2 - < -—�, � /_ hIEN WCPIH•I 0 �„r.rL i � ► _ �` ON TRAVEL DISTANCE �- I ® of 1! Rgect Nm 18676 / 54JITE TO EXIT STAIR --- I - LLL _ I Drawn By O( l0-�I" jI TRVL DISI Dee is"1"�M,4X(GOt I I 07Mr" BW&-"* e 0 N I _ o UD mINSIr • _�...____._._.._ - ..-___._-I�—_.___. _. _.li.__-._._ _ _ _ - ._ .._ _. _ _.. .....__. _ _... ...__fir'`- __�JL_- T __ �__. __. ____ __ ___ g N Reference only p \lot hart of this permit 0 LIFE SAFETY PLAN LS1.0 _era iy OO U'fr e_ UN e'm�N r-0- LIFE SAFETY PLAN �— DEMOLITION CODED NOTES DEMOLITION GENERAL NOTES o - --- -- - A. 6.G.TO VERIFY ALL CONDITIONS AND DIMENSIONS IN FIELD PRIOR TO BID AND V v � 1 O REMOVE EXISTING YV�..LS, DOOR.a, 51DELI&HT5, FRAMES, INTERIOR GLAZING, NOTIFY ARCHITECT OF ANY IWONSISTENG'.E5. W MILLWORK, AND GUB SFIOWN DOTTED THROU&HOUT SPACE. ' e o B. 6L. TO REMOVE AND PROPERLY DISPOSE OF ALL ELB-IENTS TO BE DEMOLISHED. ~ '6e z O EXISTING WALLS TO REMAIN. G.C. TO VERIFY CONDITION OF WALL 6 REPORT ANY o a �I DAMAGES TO CBRE PROJECT MANAGER. PREPARE 5URFACE5 FOR NDN FINISHES. G. 6.G. TO FM40VE ANY EXISTING SUi6LAR ALARM SYSTEM d ASSOCIATED DEVICES. _ c o Oo .1 O REMOVE EXISTING FLOORING TTMROUGF1011T SPADE. D. 6.C. TO REMOVE ANY EXISTING ELECTRICAL SYSTEMS,THERMOSTATS,SMOKE U E d N DETECTORS,AND DATA CABLING THROUGHOUT SPADE. REFER m1.0 FOR CONTENT. I++ G IYI 7 E. FIRE ALARM SYSTEMS TO REMAIN ACTIVE t TO BE PROTECTED DURIN6 Q 'ti SHADING INDICATES ADJACENT COMMON AREA AND TENANT SPACES TO REMAIN. NO o o N - _ NEW WORK TO OCCUR IN THIS LOCATION. o o 4 GONSTRUGTIOK IF,FOR ANY REASON,THE ALARM SYSTEM IS TO BE DISABLED �v� DURING CONSTRICTION,THE LOCAL FIRE DB'ARTIAENT MUST BE NOTIFIED. L J EXISTING STRIX TURAL ELEMENTS, BUILDING ENVELOPE, AND DEMISING WALL TO ADDITIONALLY,TEMPORARY EVACUATION OF THE BUILDING OR A FIRE WATCH MAY W BE REQUIRED PER 2015 IFC 901.1. W REMAIN. PREP TO RECEIVE NEW FINISHES. = Y F. EXISTIN6 SPRINKLER SYSTEM TO REMAIN OPERATIONAL. MODIFY HEADS AS d OEXISTING DOOR TO REMAIN. REFER SHEET ALO FOR HARDWARE NOTES. REQUIRED TO MAINTAIN COVERA6E C W 6. 6.C.TO PROTECT AND PRESERVE EXISTIN6 BLINDS/WINDON TREATMENTS 4 1 KEY PLAN - K � *� REMOVE EXISTING GYPSUM BOARD FROM TENANT SIDE OF DEMISING WALL AT CBRe�DURT�M��TION.CLEAN t COORDINATE STORAGE LOCATION MTH VW O DIMENSIONED AREAS. REMOVE EXISTING INSLLAT10N E PREP FOR HEW INSULATION. REFER TO WALL SECTION EX - AB.I. _ V LL OREMOVE EXISTING SIDE-LITE t FRAME. PREPARE CONDITIONS TO INFILL W/ NEW FRAMING < GYPSUM BOARD. OREMOVE EXISTING SINK. REMOVE PLUMBING BACK TO SOURCE AND GAP. REFER TO PLU MBIN6 6.C, TO COORDINATE PATH LANDLORD ON ANY MATERIALS THEY WISH TO SAVE FROM THE SPACE PRIOR TO VEMIOLITION. THESE ITEMS ARE TO BE PRESERVED IN A LOCATI ON OF THE LANDLORD' DEV64ATIOK rv^r arewr r..�r•� IN TYP rrrr r rr r..r.p w dw�M.f.�.ANrot 7Yr - r�r rr r.wr.rr r r rre.�r rr rnr r rwy rr�.r rr�r \. I IRIN BASE \ TYP / IN BASE Ia IN BASEI IN BASE 10 N BASE (I I rfP »\ TYP II I II it II I � �\�\\ TYP TYP NIN — IL FrTr II II II I III � I I I 1 III - - - - - � L Tyr I I L — � S SIDW I9 TYP TYP 9 I ( 1 \, �\ 3 II I I — _ '� I TYP wFr-1 +6° I B37IIIl+�o3TYPII TMP II I 5 II II s .� II L = = � — _ _ � _ I TYP \� , . A °� , A W 41 A1\0001 .. .. f Z W \� TYP � 'jcc 0 W O w h \ \ Jzcc m \1 1 v \ L I ` O IXO Dmm W CK Daft Iwo TYP7(4 \ \NNEW TYP a ffQFlietere ce only D1.0 O Y ���� '4ot part of this permit DEMOLITION FLOOR PLAN hg a 1/4' u a• - r-V oBAonoN ia FLOOR PLAN DEMOLITION CODED NOTES DEMOLITION GENERAL NOTES o E O O A. 6.C. TO VERIFY ALL CONDITIONS AND DIMENSIONS IN FIELD PRIOR TO BID AND U Q - REMOVE ALL CEILING 68.05, HEADERS, LAY-IN TILES, L16HTIN6, DIFFUSERS, GRILLES, NOTIFY ARCHITECT OF ANY INCONSISTENCIES. AND EXHAUST FANS SHOWN DOTTED THROUGHOUT SPACE. w Cow a B. GC, TO REMOVE AND PROPERLY DISPOSE OF ALL ELEMENTS TO BE DEMOLISHED. _d; o x OREMOVE AND DISPOSE OF EXISTING EMERGENCY FIXTURES TFIROU6H1011i SPADE IN o e r PREPARATION FOR NEW EMER6ENCY FIXTURES. REFER EDI.O FOR CONT. O. 6C. TO REMOVE ANY EXI5TIN6 BURGLAR ALARM SYSTEM t ASSOCIATED DEVICES. _ 2 o o` �r ! D. GC.TO REMOVE ANY EXISTING ELECTRICAL SYSTEMS,THERMOSTATS,SMOKE V E.O R NOT USED DETECTORS,AH✓D DATA CABLING THROU6NOUi SPACE. REFER EDLO FOR CONTENT. w `m m --T_ E. OFFER ANY ITEMS BEING REMOVOURIN6 DEMOLITION TO LANDLORD PRIOR TO Q O ' w O 5HADIN6 INDICATES ADJACENT COMMON AREA AND TENANT SPACES TO REMAIN. NO DISPOSAL. v W NEW ORK TO OCCUR IN THIS LOCATION. FIRURI F. E ALARM SYSTEMS TO REMAIN ACTIVE a TO BE PROTECTED DURING Ac W is L CONSTRUCTION. IF,FOR ANY REASON,THE ALARM SYSTEM 15 TO BE DISABLED W K ED _. DURING CONSTRUCTION,THE LOCAL FIRE DEPARTMENT MIST BE NOTIFIED. = Y - -. - ADDITIONALLY,TEMPORARY EVACUATION OF THE BUILDING OR A FIRE WATCH MAY d �. BE REQUIRED PER 2015 IFC 501.9. 0 W 6. EXISTING SPRINKLER SYSTEM TO REMAIN OPERATIONAL. MODIFY HEADS AS F KEY PLAN REQUIRED TO MAINTAIN COVERAGE N oc x . uLL 6C.TO COORDINATE NTH LANDLORD ON ANY MATERIALS THEY W15H TO SAVE FROM THE SPACE PRIOR TO DEMOLITION. THESE ITEMS ARE TO BE PRESERVED IN A LOCATION OF THE LANDLORDS OM16MTICK Dray r a AV000 Yr�rrOr a Iabt•M.a Yr"m M.glr Y arWrFrr go ,a fiY°peF. YIM\MIIf a nr a r wp r sw arm.u.. 4rY Ir AFerM aw.flr♦Y rAab ArFa���!Y M1rFF pa�Y�r�F..p�!Sal.a♦t of C t"hh F. YNrb,ANWu f- -i-1C-I- t- -1 - 1n -{ -I F - -I - t -t -I - t /-t -I - H _t -I- t- ISI- t- � 7- _ 7TT -SII-I - OTYP - � - Tri � - -I - I F - I � -I - � - � �I I _ 17 III II I I 11 I _ I - I II II Ii II 11 II II II 111 IIT I III I - T �\ „� I� AL A � -+ - -� - IJ 77 }- -I - -t -I - L � LL _ L1►- - � - � - -I � � _ - 1- \ \�\ i I I I I i I I IIII I I IIII I I I I I IIITYP -nrTI� + � + , , �I - - =i-�I- f=if -Al 11 �_ _t 11-1 - L i J -I - L -i - -I - -I - � -I�\ - JCI -I - L�1Ll -U-14- -1 TMP L L -1 JJ LLI _ I I _ I_ I i _ I - I_ I I - I- �� W 1 I I 11 I I I I IIII \ 1 I}-I - 4 I-1- - �- 111 - \ - -1 - h -�- - - - -� - -� II - � 1 11 I - 1 -I jjL[ 111 �II�I I I I � I�I 11 IfiI \ Tv � f� ±171 + -i �\ \-\ � F + -i - + � - Z- IIS -1 - � t -\IWII � III� - - L - -1 ��\I _ L -1 _I \ _ -1 - -\ I1' -� �- - I nr - I +E _1 _ t _T I 11 -T- I i -I - 11 I - 1 1 -1 - II 11 i�� - - -i iI� t 1 \\ i=:U A- LJL _ L1 \ _ L -1 \1 - L -1 -1 L -I - _I__ -1 - 4- -1 - a11 --I_ -I - -- -I - 4__IN � Iitl \\ \ , \\ \ \ \ \\\ \ -I _ I II III I I - I II II ws 1 I I I hl I I� . ,.. V ��. � �; :�` I — — — — V�\ L4 -1 - t- _1._ -1 - 1- 4 \ _ � � - 1_ �- � \ \. A 111 Ik- � \\ y\\\\\\\\y\\ A A T1i � �l f� 1 1- rt I fi rt I fiII u LaW \�,�' - � I1 � + -SII \ � 11jA �1p�- � -� \- - I�7� � +�' q — � — L amu!— —( — — Z Z w - A TYP TF J W 2 \; I I I I I I I I I I I I � aLmu> ccny c m I I I I I I I I i I I I 11 I �® "' 0 x < 1 A --- --- — I — t— —h-h— t— —h In — t— -t — I�f Ftz 0 i$ < _ - I bii bd 1 \ - ijL[ I 1 1 F I I 1 1 1 131 Nw, �T6 -I - Daft bm \ \\_\\\, mil er..x \\ ' _i _ i_ I _I _ 1_ 1 1 _ 1_ — — + hri — f1tI — fIft � z � fi — Ih — �:�� WAI I Iu TYP ijI I z _ T T - 1 � i - l­- t -}�`I- t -i - �\ - i- t -t - i Reference only ae ! D1.1 gg'y Not part of this permi� o�Ye DEMOLITION CEILING PLAN 0� r `0 1/4' T-0' DE110LRN)1�1 m a' LM PLAN F- 0 E 0 0 U Lu N H O D M X 2cc 00 T O O p EXISTING ROOF TOP UNIT SCHEDULE MECHANICAL SYMBOL/ABBREVIATION LEGEND v EId« ell W m« FAN DATA COOLING HEATING ELECTRICAL DATA Q 0 x6 SYMBOL DESORPTION ABBREVIAT DESORPTION N U& MARK MANUFACTIIER MODEL TONS EER WEIGHT NOTES TOTAL O.A. E.S.P. �M TOTAL SENS. EAT AMB. HEATING MBH POWER-MCA ® TEMPERATURE SENSv* AD ACCESS DOOR W CF CFM 'WG MBH MBH DB/WB DB V/PH W Y THERMOSTAT AL ACOUSTICAL LINING = (E)RTU-7 CARRIER 48TCOD14 12.5 5000 235 0.8 -- -- 150.0 108.5 80/67 95 180/120 10.8 -- 208/3 71 80 1, 2 ® REMOTE TEST SWITCH co CEILING DIFFUSER IL DUCT SMOKE DETECTOR GTE CONNECT TO EXISTINGW (E)RTU-8 CARRIER 48TCDD14 12.5 5000 100 0.8 -- -- 150.0 108.5 60/67 95 180/120 10.8 -- 208/3 71 So 1. 2 H (E)RTU-9 CARRIER 45=14 12s 5000 100 0.8 -- -- 150.0 1085 80/67 95 16D/120 10.8 -- 206/3 71 So 1. 242)-- DO OF CONTRACT, CONNECT 111 DOSING DDC DIRECT DIGITAL CONTROL a .- - F ARE DAMPER EG EXWWJST GRILLE (E)RTU-11 CARRIER 48TCDD14 12.5 5000 100 0.8 -- -- 150.0 1085 80/67 95 180/120 10.8 -- 206/3 71 BD 1, 2 _ M MOTORIZED DAMPER EAT ENTERING AIR TEMPERATURE V W VOLUME DAMPER EF EXHAUST FAN -IGSICD COINNG DIFFUSER ETR DUSTING TO REMAIN 1. CONTRACTOR SHALL PERFORM ROUTINE SERVICE INSPECTION OF ALL EXISTING EQUIPMENT TO BE REUSED. LUBRICATE BEARINGS, SERVICE CONTROL SYSTEMS, REPLACE FAN BELTS AND INSTALL NEW FILTERS. SUBMIT RETURN GRILLE fD ARE DAMPER REPORT INDICATING CONDITION OF UNIT AND REPORT ANY COMPONENTS FAILURES OR MALFUNCTIONS. REPORT SHALL INCLUDE COST TO REPAIR ALL ITEMS INDICATED. EQUIPMENT SHALL BE PLACED IN FULL -�RG_ OPERATION UPON COMPLETION OF PROJECT. 2. FIELD VERIFY TONNAGE AND CFM AMOUNT PRIOR TO START OF WORK. ®EG fD(HAUST GRILLE FPC FIRE PROTECTION CONTRACTOR GC GENERAL CONTRACTOR -Ar-g* AIRFLOW DIRECTION UT LEAVING Aft TEMPERATURE L b LOUVERED DOOR MCA MINIMUM CIRCUIT AMPIM -Lr-b- UNDERCUT DOOR MOD MOTOR OPERATED DAMPER OUTSIDE AIR CALCULATIONS MOCP MAXIMUM OVERLOAD PROTECTION neYw.ea eonehueMn mwmanu u CA OUTSIDE AIR N.hYmeol..I ur.ma Ys plv.n m REOLARED PROVIDED oonfY.nea.en r.m.m tM property of OUTDOOR AIR RA F ~A,aYm� Tm u.e ZONE CLASSIFICATION AREA po.e.oma,Mn ne OURCE TAO SUPPLY RETURN OA EXHAUST RN G .f mu eeem..na mu.eon.vammn / pKlfk gOla,nvMG MrM Y ehlcny RATE CFM/ OSA PERCENT SUPPLY OSA RC. RETURN GRILLE eu o,pur PEOPLE (CFMlFTA2 PFASON (CETT) OSA (CF1L (OSTIA ^Masa X \ � � REM ��� I Lntl.topnv F. Work,Arcnlbct. OFFICE OFFICE (E)RTU-8 640 0.06 10 5 Be 0.10 1050 100 UP DOWN OPDOWN UP DOWN RLA RUNNING LOAD AMPS - _.__ RTU ROOF TOP UNIT OFFICE OFFICE (E)SU-9 468 0.06 6 5 58 0.06 1650 100 TURNING VANES COUSTIC LININ SPIN-IN BRANCH SA SUPPLY AIR W/MANUAL DAMPER -- - - - OFFICE OFFICE (E)RrU-11 684 0.06 10 5 91 0.06 1675 100 OFFICE OFFICE (E)RTU-7 236 0.06 4 5 34 0.14 250 WAITING/RECEPT RECEPTION AREA (E)RTU-7 557 0.06 32 5 193 0.31 650 200 BASED ON 2019 OREGON MECHANICAL CODE HANGER-��_- -_ F tq"� DIFFUSERS AND GRILLES MIN SPIN-IN FITTING: WITH SCOOP AND ROUND FLEX INSULATED FABRICATE SHEET STEEL ELBOW�� ( DAMPER, EXCEPT METAL PLENUM BOX MARK YAfiFACTLAIER MODEL MATERIAL FRAME MAX NO NOTES IN GYP. BOARD OVER DIFFUSER DUCT CEILINGS, DAMPER SPIN-IN FITTING PAINTED BLACK INSIDE J?�UR IN NECK AIR CD-1 PRICE SPD STEEL 24524' LAY-IN 25 1,2,6 SECURE W/ WRAP INSULATION FLOW DRAWBARD AROUND PLENUM BOX F- - ROUND STEEL NOMINAL ( TAPE AND MASTIC 1 1/2• WRAP LD-1 PRICE SDS1OO STEEL TYPE 15 LAY-IN 25 2,4 FLEX DUCT, MAX. DUCT W/SPIN-N 24'x24' LAY-IN PANEL Ny 1 OUTER JACKET BRANCH DUCT INSULATION ABOVE RG-1 PRICE 600 ALUMNW 240x24' LAY-111 25 2,3,6 LENGTH 5' 0' FITDNG ARD (FLOW (TYPE) SIZE +3' CEILING, 3- WRAP IN RG-2 PRICE 600 ALUMINUM 24'x12' LAY-111 25 2,6 VOLUME DAMPER NECK/DUCT ATTIC SPACE. SECURE W/ SIZE -' LR-1 PRICE SDR150 ALUMINUM TYPE 15 LAY-W - 2,5 DRAWEAND CEILING DIFFUSER:ROUND SHEET METAL SET THROW AS ROUND STEEL DIfFUSEP WITH 1 1/2'WRAP SHOWN ON PLANS GYNE NOq ERS SHALL 6E 4-WAY THROW UNLESS NOTED OTHERWISE EXTENSION � INSULATION ABOVE VOLUMECEILING, C WRAP IN 2. DIFTUSERS/GRILLES SHAIl BE PAINTED TO MATCH CEILING GRID. COORDINATE WITH ARCHITECTURAL PRIOR TO PAINTING. ATTIC SPACE. 3. PROVIDE WITH PRICE RETURN AIR CANOPY WITH FIBER FREE FOAM ACOUSTIC MEDIA (RAC). NECK/DUCT I r--SIZE4. 1-SLOT UNEAR DIFFUSER WITH 4FT SUPPLY PLENUM (MODEL SOB), 5' INLET. -j 5. 1-SLOT UNEAR RETURN, 4 FT LONG. NOMINAL 2 LIMITED SPACE CEILING DIFFUSER CONNECTION DETAIL 6. PROVIDE SPF/APF FRAME FOR DRYWALL CEILING. REFER TO ARCHITECTURAL CEILING PLAN PRIOR TO ORDERING, 24'x24' LAY-IN PANEL N.T.S. GENERAL NOTES: # DIMENSION SHOWN ON MECH A OPPOSED BLADE DAMPER. PLAN IS DUCT/NECK SIZE B. PROVIDE SQUARE TO ROUND NECK TRANSITIONS WHERE ROUND DUCTS SEINE SQUARE NECK DIFFUSERS OR GRILLES. C. PROVIDE VOLUME DAMPER IN BRANCH DUCT RUN-OUT WHERE CEILNG IS ACCESSIBLE. D.B. DAMPER BEHIND GRILLES OR DIFFUSER IS REQUIRED WHERE DUCT BRANCH IS INACCESSIBLE. 1 LAY-IN DIFFUSER DETAIL D. PAINT INTERIOR OF DUCTWORK BEHIND GRILLES AND DIFFUSERS FLAT BLACK IF VISIBLE THROUGH DEVICE E. CONTRACTOR SHALL CONFIRM EXACT LOCATION OF DIFFUSERS AND GRILLES WITH GENERAL CONTRACTOR TENANT h N.T.S. ,MAX, so' ARCHITECT PRIOR TO ANY WORK. _� _ SEE NOTE 3 r TAKEOFF DETAIL If ' OVER 6°' I 5 RECTANGULAR DUCT BRANCH FINGER N.T.S. THREADED I ' HANGER ROD INSULATION - BLANKET SHEET METAL WRAPPED SCREWS (TYP.) , AIR UNISTRUT OR FLOW ANGLE IRON , PRICE RAC (RETURN AIR CANOPY) WITH ACOUSDC OPTION /�'PROVIDE WITH FIBER yl (FIBER FREE MEDIA) / FREE FOAM // ACOUSTICAL MEDIA \ RETURN AIR CANOPY `SPIN-IN COLLAR FITTING NOTES' LAY-IN CEIUNG �� u 1. ON DUCTS OVER 48' WIDE, BOTTOM SHALL BE BRACED BY ANGLE.FOR CROSS SECTION AREA MORE -- -- �� - SEAL WITH MASTIC AND THAN 8 SO FT, DUCT SHALL BE BRACED BY ANGLES ON ALL FOUR SIDES. / �-�� C � DUCT TAPE 2. CUTTING AND PATCHING SHALL BE LIMITED TO A MINIMUM AS REQUIRED FOR PROPER INSTALLATION. RETURN GRILLE W 3. SUPPORTS SF4LLL BE SPACED AND SIZED AS PER SMACNA 6 RETURN AIR CANOPY � ~ DURO-DYNE RB-25T y SOLID RAPID VOLUME 4 DUCT HANGER SUPPORT N.T.S. Q�j w W _ DAMPER [� J Q N.T.S. T W � y N N ROUND STEEL DUCT _ 2 Y W a a O O Z � Q TAKEOFF DETAIL z a 3 ; ROUND DUCT BRANCH 1� N.T.S. Ft"M Nw 16675 F OLIiiOL Bye JPU_- D.r r.,. NY71B1m21 111yPa11R e = u t � v 0 f y O J x o r a' a 4 U d V y 0 Ivo SAe m1n 0 E 0 0 Occ C) 0 Edi w Lu UJ IL 0 Lu SII U) I'X IF— DEMOLITION GENERAL NOTES _T A k_-4 GUIDELINE FOR DEMOLITION. THE CONTRACTOR MUST VISIT THE SITE r 1. THE ARCHITECTURAL DRAWINGS ARE TO BE USED ONLY AS 1 1-1 1 PRIOR TO BIDDING TO VERIFY ALL WORK REQUIRED FOR A COMPLETE f JOB AND INCLUDE THE COST OF SUCH WORK IN HIS BID. 2. THE MECHANICAL DRAWINGS ARE INTENDED TO SHOW ONLY THE 6 GENERAL EXISTING BUILDING CONSTRUCTION WITHIN THE AREA OF DEMOLITION. THE DRAWINGS DO NOT SHOW ALL SYSTEMS, QUANTITIES, IN, SIZES, OBSTRUCTIONS, ETC., AND ARE NOT INTENDED TO BE USED BY THE CONTRACTOR TO BERNE THE COMPLETE SCOPE OF DEMOLITION. THE CONTRACTOR MUST FIELD VERIFY THE ACTUAL BUILDING AND SYSTEMS CONDITIONS TO DEANE ALL ELEMENTS WITHIN THE SCOPE KEY PLAN OF DEMOLITION. ft.q. 3. EXAMINE AREAS AND CONDITIONS UNDER WHICH DEMOLITION WORK 1132' T-O' MUST BE PERFORMED. THIS CONTRACTOR SHALL COORDINATE HIS of th.a..yn I"mm conurocnln WORK AND/OR V�l�"r"w smctly DEMOLITION tw WORK WITH OTHER TRADES PERFORMING DEMOL DEMOLITION WORK PERFORMED BY THE OWNER. IN EVERY INSTANCE \ I / (E)7f .1 cwml.pm,F. WK..AmwuDl. OF DEMOLITION AND/OR REMODELING, THE CONTRACTOR SHALL 2 FIGURE A COMPLETE JOB AS NONE OTHER SHALL BE ACCEPTED. (D 8 3)(E)RTU 4. THE EXTENT OF WORK SHOWN OR NOT SHOWN SHALL INCLUDE \�\ i _-- I . `�X ' (E)7"O REMOVAL AND LEGALLY DISPOSE OFF SITE, ALL THE ITEMS AND 11 ( II /El "I El e, SYSTEMS BEING REMOVED. �\�\\\\\ ___ _(E)7'0_4 -------------- 5. THIS CONTRACTOR SHALL RETAIN ON THE PREMISES IN NEATLY -- ---- ()E)7 1 -1 STACKED PILES WHERE INSTRUCTED FOR SELECTION BY THE OWNER, (E)7-0-/# e\-(E)7-0 1 ALL MATERIAL, WIRE, FIXTURES AND/OR EQUIPMENT WHICH ARE (E)7"oAl SPECIFIED TO BE REMOVED OR REPLACED. ALL SUCH ITEMS, NOT _j==L --- IIS SELECTED FOR SALVAGE BY THE OWNER, SHALL BECOME THE LL PROPERTY OF THIS CONTRACTOR AND SHALL BE REMOVED FROM THE 14'0c) III PREMISES AND LEGALLY DISPOSED. -0 1�13 6. CONFORM TO ALL APPUCABLE CODES FOR DEMOLITION OF ITEMS AND �VE) (E)12 �N SYSTEMS, SAFETY OF ADJACENT SYSTEMS, DUST CONTROL, LEGAL RUN-OFF CONTROL, DISPOSAL AND ALL ITEMS NECESSARY TO -------- COMPLETE THE WORK COMPLETELY. \\\\\ _ / W 1 I 7. DEMOU11ON SHALL BE DONE IN A MANNER SO AS NOT TO DAMAGE ADJACENT WORK AND NOT AFFECT THE OPERATION OF SYSTEMS TO (E)10*0 1 REMAIN IN USE. ANY ITEM TO REMAIN THAT IS DAMAGED BY THE CONTRACTOR SHALL BE REPLACED AND/OR REPAIRED AT THE (E) CONTRACTOR'S EXPENSE. (E)IO-0 4 5 B. DEMOLITION AND CUTTING SHALL BE DONE IN A MANNER WHICH DOES 7-0 7"0 NOT DEFORM OR APPLY LOADS TO THE EXISTING FRAMING AND r(E)12'01 EQUIPMENT OF THE BUILDING TO REMAIN. LL Lt; 9. ALL WALLS, CEILINGS, FLOORS, ETC., BEING DISTURBED BY THE WORK SHALL BE RETURNED To FINISHED CONDITIONS TO MATCH EXISTING BY THE CONTRACTOR AND CONTRACTOR SHALL DO HIS OWN CUTTING AND (E)1 6.040 3 PATCHING AS NECESSARY UNDER HIS CONTRACT. 3 2 ---7 1", 1 Li (E)7-0 IT T WrO 11 (E)M-7 310. THE CONTRACTOR SHALL MAINTAIN EXISTING SERVICES TO AND IN THE 1 11 1 F(E)7-0 EXISTING AREA AS REQUIRED. Yui (E)7-0--4 11. THE EXISTING SYSTEMS TO REMAIN ARE TO BE SUPPORTED AS REQUIRED UNTIL THE MODIFIED ELEMENTS ARE INSTALLED AND II ---------- SUPPORTED. 12. IF NECESSARY, THE CONTRACTOR SHALL PROVIDE TEMPORARY 4_1 (E)I0-0(D SERVICES IN THE EXISTING AREAS. (E)7"0 13. EXISTING CSLABS SHALL BE SAW-CUT IN A MANNER THAT DOES NOT AUSE THE STEEL FRAMING OR THE REBAR SUPPORTING THE SLAB TO BE CUT. CONTRACTOR SHALL FIELD VERIFY SLAB THICKNESS AND REBAR SPACING. 14. EXISTING SLABS SHALL BE CORE DRILLED AT REENTRANT CORNERS OF NEW FLOOR OPENINGS TO PREVENT OVER CUTTING. IF EXISTING SLAB IS A STRUCTURAL SLAB, CONTRACTOR SHALL CONTACT ENGINEER Lx ON HOW TO PROCEED. :j (E)12-0 15. THE ELECTRICAL CONTRA" SHALL DISCONNECT AND REMOVE ELECTRIC SERVICE TO ALL MECHANICAL EQUIPMENT BEING REMOVED AS A RESULT OF THE RENOVATION. 2 16. EQUIPMENT AND DEVICES SHALL BE REMOVED COMPLETE INCLUDING HANGERS, SUPPORTS, CONTROLS. CONDUIT, WIRE, PIPES, DUCTWORK, (E)RIU-D 11 ETC. WIRING SHALL BE DISCONNECTED AT CIRCUIT BREAKERS, REMOVED AND BREAKERS MARKED 'SPARE.- 17. ALL OPEN ENDED PIPING AND DUCTWORK THAT IS TO REMAIN SHALL X� BE CAPPED AND PROPERTY SECURED. �(E)STATIC PRESSURE BYPASS DAMPER -(E)8"o 18. ANY EXISTING PIPES, DUCTWORK, CONDUIT, LOW VOLTAGE CONTROL, L - WIRING AND/OR ELECTRICAL AND MECHANICAL DEVICES BEING 3 - - -- ---r- - --T-:, ----- - -0 DISTURBED BY THE WORK SHALL BE REWORKED BY THIS CONTRACTOR it , (E)8 (E)ION AS REQUIRED TO RETURN TO ITS FORMER EXISTING OPERATING CONDITION. r'r ( 19. ANY PIPES OR DUCTWORK, OR CONTROL WIRING, OR TUBING FEEDING THROUGH DEVICES OR EQUIPMENT BEING RELOCATED, REWORKED, OR ABANDONED AND SERVING OTHER DEVICES, AND/OR EQUIPMENT SHALL BE MAINTAINED IN WORKING CONDITION. (E)54,28 20. ANY ASBESTOS REMOVAL IF REQUIRED WILL BE HANDLED BY THE u OWNER AND IS NOT A PART OF THIS WORK. C3 21. EXISTING ARCHITECTURAL, MECHANICAL AND ELECTRICAL EQUIPMENT AND SYSTEMS SHALL BE PROTECTED FROM DAMAGE RESULTING FROM Lu 0 DEMOLITION. ow 5 22. CONTRACTOR SHALL SUBMIT A PROPOSED DECONSTRUCTION SEQUENCE _0v TO THE OWNER AND ARCHITECT FOR REVIEW PRIOR TO F ---,,v- -IF -4)2y-- -F COMMENCEMENT OF WORK. a) UJ ui z uJ 23. CONTRACTOR SHALL PROTECT ALL EXISTING RETURN DUCTWORK AND _J 2 cc c') < LLI F- (E)54x2ll�loTRANSFER AIR OPENINGS WITH DISPOSABLE FILTERS DURING LU > w -- ----------I CONSTRUCTION. FITESHALL BE OF THE DISPOSABLE TYPE AND 0 I II SHALL BE MERV B.LRP LACE EXISTING BUILDING UNIT FILTERS AFTER x X jL cc< 0 CONSTRUCTION IS COMPLETE. 0 E)STAnd PRESS RE �DCQDED NOTES cc (E)STATKJL 41, _.agol�ll) Z5 BYPASS DAMPER �0 C<9 1. EXISTING SUPPLY AIR MAIN TO REMAIN. FIELD VERIFY EXISTING CONDITIONS PRIOR TO STARTING WOW. 2. RELOCATE EXISTING THERMOSTAT TO NEW LOCATION ON DRAWING j-(E)16-00 Z(E)14:-OG) (E)12-0 (E)8-0 M2.0. p Nd IBM-----------fir------ -/_-_I------- (E)8.0 ri- rr' I 11 3. REMOVE ALL BRANCH DUCTWORK AND DIFFUSERS AND CAP AT BY. JFU I i DUCT MAIN AIRTIGHT. I om Is" (E)800 (E)S"o 4. REMOVE EXISTING SINK IN ITS ENTIRETY. CAP EXISTING SANITARY, VENT AND CW AT MAINS. 07100M BkPwffdt 5. REMOVE EXISTING MINI TANK HOT WATER HEATER IN ITS ENTIRETY. CAP CW AT MAN. _JL- *v - ------—----- - PRIOR TO DEMOLITION. CONTRACTOR SHALL -A EVALUATE ALL THE EXISTING ROOFTOP 2 UNITS INDICATED FOR REUSE. THEY SHALL CONFIRM ALL THE SPACES EACH UNIT SERVES, INCLUDING EXISTING ADJACENT SPACES IN ORDER TO REWORK EXISTING DUCTWORK AS REQUIRED TO MAINTAIN THESE SPACES AS THEY ARE CURRENTLY SERVED. CONTRACTOR SHALL ALSO ENLIST THE SERVICES OF AN AIR BALANCING AND TEMPERATURE CONTROLS CONTRACTOR TO CONFIRM EXISTING AIR FLOWS REQUIRED WILL BE MET AND PROVIDE AND ADDITIONAL CONTROLS ETC. TO ENSURE A FULLY FUNCTIONAL SYSTEM. CONTRACTOR o SHALL NOTIFY ARCHITECT SHOULD ANY UNCOVERED CONDITIONS REQUIRED MD1. MECHANICAL DEMOLITION PLAN ADDITIONAL DIRECTION. N 0 1-0- MECHANICAL DEMOLITION PLAN o E 0 0 U a u Ltl m > 3 0 _ D Y x m � T p 0 2 O_ p TL Uo0 c o Edi W a vi Q O O N h m u N U N W W Y x O Lu I I � eg x i t - � N - - - -- -- ,-,- - - ----- - -- OFFICE 1 - _0 CFM OFFICE 2 OFFICE 8 OFFICE 4 -- - \��\\ COUNSELNI CD 1. COUNSELING COUNSELNG COUNSELNG COUNSELING 10"o OFFICE 6 Mnu•onb of norwu oro pun x, KEY PLAN \\ \\ 101 los los 104 �Ob- I on•r«..y.MWwtye 1/32' . T-0' \� \ CD-I, 4'(�- CD 1, ��• .1.weM"F. n 200 C (1 200 C n 200 CFM 475 CFM of nw xoYn mx mn•o earouwUon 8"0 3 8.0 8"o 12"o ( ee gwft p �n ww yy \\ - of C lop ,F. Ylrko,Ar A 1. CD-1 t' y�lYnl Ms�apYY�r�Iw miYM tax - ear CFM - - - COUNSELING to'• a"m RG-1. c-1 �I RG_1. a"m I RG-1, (�ji Rc-1. OFFICE 7 24x24 - 24x24 4 � - 24x24 - 24x24 II 107 24x24 E)14 0 _U Ulu r r- (E)12•+ (E)1D'+ a"+ 7 I MECHANICAL GENERAL NOTES: LD-1. 6"o 1. CONTRACTOR SHALL PROVIDE All LABOR, MATERIALS, TOOLS AND CFM CLOSET 1 arL 1 75 CFM I 1 12"0I EQUIPMENT TO INSTALL A COMPLETE AND OPERATION HEATING AND 50=1 24,24 O TYP- (4) HALL 8•+ �-y COOUNG SYSTEM. --- - - -- V L - -- -- --- 002 2. CONTRACTOR SHALL PROVIDE ALL REWIRED HVAC PERMITS. COUNSELING (E)R1U-7 I I RG-1. I OFFICE 8 3. THE APPLICABLE CONTRACTOR SWELL COMPLY WITH NFPA-90A AND ALL 24x24 APPLICABLE CODES. F_ 1 I 2200 C ROOM I - COUNSELING lob U I ❑ ❑ ® OFFICE 5 2RG-1. 4. ALL HVAC WORK TO BE PERFORMED SHALL BE IN COMPLIANCE WITH ALL STATE AND LOCAL CODES. 24_ _ _ _ t 0"o 5. FLEXIBLE DUCT SW41 COMPLY WITH SMACNA, Nl LOCAL CODES, U.L. x24 8+ U 6*0 _/-6*0 CDCD=1, RATING, AND NOT EXCEED FIVE FEET IN LENGTH, SHEET METAL DUCT, 300 CfM WHERE REQUIRED BY LOCAL CODES, SHALL BE LINED WITH 1" MATT I FACED DUCTUNER IN THE FIRST 10 (TEN) FEET OF THE RETURN AND (E)18"+ (E)16"+ 14"+ • 12"+ 10"o SUPPLY DUCT STARTING FROM THE HVAC UNIT. AFTER THE FIRST 10 I 8"0 10"0 (TEN) FEET THE USE OF 1" DUCT WRAP SHALL BE ACCEPTABLE WORK MATERIAL TO BE VERIFIED WITH CEILING ACCESSIBILITY RATING. 10"o I 0250 CFM 6. THE ELECTRICAL CONTRACTOR SHALL PROVIDE ALL SWITCHES, 1 I V y 250 - --- -- DISCONNECTS, AND CONTROL WIRING. I I 4 CD-1"I 10"o - - COCO- 7. ALL DUCT SIZES ARE CLEAR INSIDE DIMENSIONS, ALLOW FOR DUCT ' t WAITING I 200 s INSULATION. U 250 CFM 8"+ 10"o RNA I - 8. THE CONTRACTOR SHALL PROVIDE A WRITTEN GUARANTEE THAT SHALL Dol 1 1 CD-1, WARRANT ALL WORKMANSHIP AND MATERIALS FOR ONE (1) YEAR I RECEPTION 4 300 CFM FROM THE FINAL WORK ACCEPTANCE BY THE OWNER AND A FIVE / " ii -..... 601 - (E)RIU-11 10"o I YEAR WARRANTY ON THE COMPRESSOR. ! RG-1, 9. CONTRACTOR SHALL PROTECT ALL EXISTING RETURN AND TRANSFER 24"24 2 " C NSELING NR OPENINGS MRH DISPOSABLE FILTERS DURING CONSTRUCTION. FILTERS SHALL BE OF THE DISPOSABLE TYPE AND SHALL- BE MERV S. FIC REPLACE EXISTING BUILDING ROOFTOP UNIT FILTERS AFTER 9 ����_ r CONSTRUCTION IS COMPLETE jj. 9�,� 10. CONTRACTORS SHALL INSTALL ALL NECESSARY OFFSETS, BENDS, AND Iv� TRANSITIONS REQUIRED TO PROVIDE A COMPLETE SYSTEM AT NO L-.-.-�..____-_-_. (�t2"+ �. ADDITIONAL COST TO THE OWNER. 7� I 11. COORDINATE LOCATION OF ALL CEILING DIFFUSERS, GRILLES AND r�� /� 8 LD__L REGISTERS IN THE FIELD WITH THE ELECTRICIAN TO PREVENT II / II RG-i. 75 CFM 12"0; I CONFLICT WITH UGHTS AND ARCHITECTURAL ELEMENTS. 'IIS///�J-JI1 24x24 6•+ ---.------ - --�- - L- 8"0 10•+ 3CD_1 _ I 12. ALL WORK A THIS TRADE RFER BE COORDINATED WITH ALL OTHER TRADES TO AVOID ANY INTERFERENCES THAT MAY DELAY PROGRESS 00 FM DURING CONSTRUCTION, 250 COM 10'0 .10"o 13. THE MECHANICAL CONTRACTOR SHALL TEST AND BALANCE TO THE AIR BREAK (E)STATIC t2'o COUNSELING I QUANTITIES ON THE PIAN AND PROVIDE A T&B REPORT. ______ ROOM PRESSURE _ OFFICE 10 4. CONTRACTOR SHALL INSTALL EMPLOY A TEMPERATURE CONTROLS BYPASS r CONTRACTOR TO MODIFY/REWORK EXISTING TEMPERATURE CONTROLS - 6"0 301 DAMP I I RG-1 10 TO PROVIDE RE-ZONING SHOWN ON PLAN. -� 24x24 II L J 15. COTRNRSHALL INSTALL MNU BALANCING DAMPERS AT ALL SUPPLY RBRANCH DIKN I \ - -- 16. CONTRACTOR SHALL INSTALL TURNING VANES AT ALL DUCTWORK TEES 6"0 _ AND 90 DEGREE ELBOWS. f_ 1 17. ALL SHEET METAL DUCTWORK SHALL COMPLY WITH SMACNA - STANDARDS. ALL DUCTWORK JOINTS SHALL BE TAPED AND SEALED. D­ 30I. FM I 18. CONTRACTOR SHALL PRONDE EQUIPMENT OF THE SCHEDULED w' ( (E)54x28 10.0 CAPACITIES DESIGNED. W ___ Ln E)RTU-11 - 2 COUNSELING OX CODED NOTES = g 1. CONNECT NEW SUPPLY AIR MAIN TO EXISTING SUPPLY ANN. RG-1. 50 CFlA TELBEALTH ( FIELD VERIFY ROUTING AND EXACT POINT OF CONNECTION H OFFICE 11 24x12 6•+ RODM III PRIOR TO STARTING WORK. N I - - `112 2. UNDERCUT DOOR 1" _ -- 3. PROVIDE WITH RETURN NR CANOPY. REFER TO SCHEDULE AND LU LU DETAIL ON SHEET M1.0 FOR ADDUNONAL INFORMATION. TYPICAL J 2 R i r- -- -- -- .- --- (E)54x28 3 I ALL RETURN GRILLES. Q W I- N - 4. INSTALL RELOCATED THERMOSTAT. PROVIDE ADDITIONAL W O CFM Y _ . E CONTROL WIRING AS REQUIRED. MOUNT AT 48" A.F.F. PROVIDE _ Q 6+ RG-t, IWITH CLEAR LOCK BOX. COORDINATE FINFINALNMOUNTING1O 4x24 LOCATION WITH ARCHITECTURAL PLANS. FIELD VERIFY - O I CONDITIONS PRIOR TO STARTING WORK. L- ZN (E) KLPRESSURE �.- - cc O BYP PER - - 2 O RG-1 RG-121 24x24 rTT(l Al' 00 C - (E)14"+ 14"0 • 12"0 _ Ptow NIL 111176 -- (E)16y 10"o 1C"o CD_i. ffiy_L 1Y1x�LBx !U (E)RN-9 10"o 10"0 24x24 V1 400 CFM 0.1• M» CD 1. 10"+ D➢=L aAmAlstol ddMmt COINING 325CFM �, . 1325 0"o CFM COUNSELING f 300 r F OFFICE 15 10"+ I OFFICE 14 COUNSELING L 115 a OFFICE 18 - z JL a NOTE: i SPACE ABOVE CEILING IS UTILIZED AS A E RETURN AR PLENUM. ALL MATERIALS ABOVE COUNGS SHALL BE PLENUM ao N RATED. M2 .0 ug MECHANICAL PLAN 1 .p g� MIIeCNANT`AL PLAN �5 15001 2.04 PIPE MARKERS 2.02 GLASS FIBER, FLEXIBLE (THICKNESS SHALL PROVIDE R VALUE REQUIRED BY GOVERNING 3.03 INSTALLATION SECTION 15410 2.06 COMPRESSOR A PLASTIC PIPE MARKERS: FACTORY FABRICATED, FLEXIBLE, SEMI- RIGID PLASTIC, ENERGY CONSERVATION CODE FOR SPECIFIC APPLICATION) A INSTALL IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS, STATE AND LOCAL A PROVIDE HERMETIC OR SCROLL COMPRESSORS, 3600 RPM MAXIMUM, RESILIENTLY GENERAL INFORMATION PREFORMED TO FIT AROUND PIPE OR PIPE COVERING; MINIMUM ',NFORMATION INDICATINGA INSULATION: FLEXIBLE, NONCOMBUSTIBLE BLANKET. PLUMBING CODES. PLUMBING FIXTURES MOUNTED WITH POSITIVE LUBRICATION, CRANKCASE HEATER, HIGH AND LOW PRESSURE ~ 0 0 FLOW DIRECTION ARROW AND IDENTIFICATION OF FLUID BEING CONVEYED. 1. 'K' VALUE: 0.36 AT 75 DEGREES F. B. PROVIDE NON-CONDUCTING DIELECTRIC CONNECTIONS WHEREVER JOINTING DISSIMILAR PART 1 GENERAL SAFETY CONTROLS, MOTOR OVERLOAD PROTECTION, SUCTION AND DISCHARGE SERVICE C) m A GENERAL B. PLASTIC TAPE PIPE MARKERS: FLEXIBLE, VINYL FILM TAPE WITH PRESSURE SENSITIVE METALS. VALVES AND GAGE PORTS, AND FILTER DRIER. 1. CONFORM TO ALL GENERAL AND SPECIAL CONDITIONS OF CONTRACT AS SPECIFIED 2. MAXIMUM SERVICE TEMPERATURE: 450 DECREES F. 1.01 SECTION INCLUDES W - .m ADHESIVE BACKING AND PRINTED MARKINGS. 3. MAXIMUM WATER VAPOR SORPTION: 5.0 PERCENT BY WEIGHT. C. ROUTE PIPING IN ORDERLY MANNER AND MAINTAIN GRADIENT. ROUTE PARALLEL AND B. FIVE MINUTE TIMED OFF CIRCUIT TO DELAY COMPRESSOR RESTART. 0 N o BY ARCHITECT, TENANT AND OWNER. C. UNDERGROUND PLASTIC PIPE MARKERS: BRIGHT COLORED CONTINUOUSLY PRINTED PERPENDICULAR TO WALLS. A SINKS. C. OUTDOOR THERMOSTAT TO ENERGIZE COMPRESSOR ABOVE 35 DEGREES F AMBIENT. ~ o+ x 2. SPECIFICATIONS ARE APPLICABLE TO ALL CONTRACTORS AND SUBCONTRACTORS FOR B. VAPOR HARRIER JACKET: PART 2 PRODUCTS - • Q r MECHANICAL AND ELECTRICAL SYSTEMS PLASTIC RIBBON TAPE, MINIMUM 6 INCHES WIDE BY 4 MIL THICK, MANUFACTURED FOR o c 1. KRAFT PAPER WITH GLASS FIBER YARN AND BONDED TO ALUMINIZED FILM. D. INSTALL PIPING TO MAINTAIN HEADROOM, CONSERVE SPACE, AND NOT INTERFERE WITH USE D. FOR HEAT PUMP UNITS, PROVIDE REVERSING VALVE, SUCTION LINE ACCUMULATOR, ¢ . 0 DIRECT BURIAL SERVICE. A SEE FIXTURE SCHEDULE ON DRAWINGS. = r 3. CONTRACTOR SHALL COMPLY WITH OWNER'S STANDARDS, FACILITY SPECIFICATIONS, 2. MOISTURE VAPOR PERMEABILITY: 0.02 PERM INCH. OF SPACE. DISCHARGE MUFFLER, FLOW CONTROL CHECK VALVE, AND SOLID-STATE DEFROST CONTROL ''0 0 RULES AND REGULATIONS. ALL OWNER'S CRITERIA SHALL BE COMPLIED WITH AND D. COLOR CODE AS FOLLOWS: PART 3 EXECUTION UTILIZING THERMISTORS. C� `m 3. SECURE WITH PRESSURE SENSITIVE TAPE. E. GROUP PIPING WHENEVER PRACTICAL AT COMMON ELEVATIONS. E 'w INCLUDED IN THIS BID. CHECK OTHER PUNS AND SPECIFICATIONS AND FULLY 1. POTABLE, COOLING, BOILER, FEED, OTHER WATER: GREEN WITH WHITE LETTERS. 3.01 EXAMINATION 2.07 CONDENSER COIL w c n C .VAPOR BARRIER TAPE: F. INSTALL PIPING TO ALLOW FOR EXPANSION AND CONTRACTION WITHOUT STRESSING PIPE, COORDINATE WITH OTHER TRADES AND ARCHITECT'S REQUIREMENTS. 2. FIRE QUENCHING FLUIDS: RED WITH WHITE LETTERS. JOINTS, OR CONNECTED EQUIPMENT. A VERIFY THAT WALLS AND FLOOR FINISHES ARE PREPARED AND READY FOR INSTALLATION A PROVIDE COPPER TUBE ALUMINUM FIN COIL ASSEMBLY WITH SUBCOOUNG ROWS AND COIL o m N 4. VISIT SITE, CHECK FACWTIES AND CONDITIONS, AND VERIFY ALL UTILITY COMPANY 1. KRAFT PAPER REINFORCED WITH GLASS FIBER YARN AND BONDED TO ALUMINIZED FILM, Q REQUIREMENTS AND CONNECTION POINTS IN FIELD PRIOR TO STARTING WORK. TAKE 2.0.5 CEILING TACKS OF FIXTURES. GUARD. � w e WITH PRESSURE SENSITIVE RUBBER BASED ADHESIVE. C. PROVIDE CLEARANCE IN HANGERS AND FROM STRUCTURE AND OTHER EQUIPMENT FOR � U N ALL ITEMS INTO CONSIDERATION IN BID. A DESCRIPTION: STEEL WITH 3/4 INCH DIAMETER COLOR CODED HEAD. D. TIE WIRE: ANNEALED STEEL, 16 GAGE. INSTALLATION OF INSULATION AND ACCESS TO VALVES AND FITTINGS. B. VERIFY THAT ELECTRIC POWER IS AVAILABLE AND OF THE CORRECT CHARACTERISTICS. B. PROVIDE DIRECT DRIVE PROPELLER FANS, RESILIENTLY MOUNTED WITH FAN GUARD, MOTOR 5. SYSTEMS ARE TO BE COMPLETE AND WORKABLE IN ALL RESPECTS, PLACED INPART 3 EXECUTION 2.03 DUCT LINER H. PROVIDE ACCESS WHERE VALVES AND FITTINGS ARE NOT EXPOSED. COORDINATE SIZE C. CONFIRM THAT MILLWORK IS CONSTRUCTED WITH ADEQUATE PROVISION FOR THE OVERLOAD PROTECTION, WIRED TO OPERATE WITH COMPRESSOR. PROVIDE HIGH ds uJ OPERATION AND PROPERLY ADJUSTED. 3.01 PREPARATION / INSTALLATION OF COUNTER TOP LAVATORIES AND SINKS. EFFICIENCY FAN MOTORS. W Y A INSULATION: AND LOCATION OF ACCESS DOORS WITH ARCHITECTURAL DRAWINGS SPECIFICATIONS. 6. EACH CONTRACTOR SHALL PROVIDE FOR HIS OWN CLEAN-UP, REMOVAL AND LEGAL 3.02 PREPARATION C. PROVIDE REFRIGERANT PRESSURE SWITCHES i0 CYCLE CONDENSER FANS. _ DISPOSAL OF ALL RUBBISH DAILY. A DEGREASE AND CLEAN SURFACES TO RECEIVE ADHESIVE FOR IDENTIFICATION MATERIALS. 1. INCOMBUSTIBLE GLASS FIBER; FLEXIBLE BLANKET, RIGID BOARD, AND PREFORMED I. ESTABLISH ELEVATIONS Of BURIED PIPING OUTSIDE THE BUILDING TO ENSURE IT IS BELOW 2.08 MIXED NR CASING d 7. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR CONSTRUCTION MEANS, B. PREPARE SURFACES IN ACCORDANCE WITH SECTION 09900 FOR STENCIL PAINTING. ROUND LINER BOARD; IMPREGNATED SURFACE AND EDGES COATED WITH POLY VINYL SITES FROST LINE. A ROUGH-IN FIXTURE PIPING CONNECTIONS IN ACCORDANCE WITH MINIMUM SIZES INDICATED METHODS, AND SEQUENCES OF CONSTRUCTION AND THE SAFETY OF WORKMEN. ACETATE POLYMER, OR ACRYLIC POLYMER SHOWN TO BE FUNGUS AND BACTERIA J. INSTALL VENT PIPING PENETRATING ROOFED AREAS TO MAINTAIN INTEGRITY OF ROOF IN FIXTURE ROUGH-IN SCHEDULE FOR PARTICULAR FIXTURES. A DAMPERS: PROVIDE OUTSIDE, RETURN, AND RELIEF DAMPERS WITH DAMPER OPERATOR C W COMPLY WITH ALL OSHA REGULATIONS. 3.02 INSTALLATION RESISTANT. ASSEMBLY. 3.03 INSTALLATION AND CONTROL PACKAGE TO AUTOMATICALLY VARY OUTSIDE AIR QUANTITY. OUTSIDE AIR L_ . 8. NO PIPING, DUCTWORK, CONTROLS, ETC., SHALL BE INSTALLED OR ROUTED ABOVE A. INSTALL PLASTIC NAMEPLATES WITH CORROSIVE-RESISTANT MECHANICAL FASTENERS, OR2. APPARENT THERMAL CONDUCTIVITY: MAXIMUM OF 0.31 AT 75 DEGREES F. K. PROVIDE SUPPORT FOR UTILITY METERS IN ACCORDANCE WITH REQUIREMENTS OF UTIUTY A INSTALL EACH FIXTURE WITH TRAP, EASILY REMOVABLE FOR SERVICING AND CLEANING. DAMPER TO FALL TO CLOSED POSITION. RELIEF DAMPERS MAY BE GRAVITY BALANCED. N ELECTRICAL PANELS AND EQUIPMENT OR THROUGH ELEVATOR ROOMS OR SHAFTS. ADHESIVE. APPLY WITH SUFFICIENT ADHESIVE TO ENSURE PERMANENT ADHESION AND 1 SERVICE TEMPERATURE: UP TO 250 DEGREES F. COMPANIES. B. GASKETS: PROVIDE TIGHT FLTDNG DAMPERS WITH EDGE GASKETS MAXIMUM LEAKAGE 5 B. PROVIDE CHROME PLATED RIGID OR FLEXIBLE SUPPLIES TO FIXTURES WITH LOOSE KEY d' 9. THE MECHANICAL AND ELECTRICAL CONTRACTORS SHALL COORDINATE THE SEAL WITH CLEAR LACQUER. 4. RATED VELOCITY ON COATED AIR SIDE FOR AIR EROSION: 5,000 FPM, MINIMUM. PERCENT AT 2 INCHES PRESSURE DIFFERENT6LL. _ ELECTRICAL CHARACTERISTICS OF ALL MECHANICAL EQUIPMENT PRIOR TO ORDERING L INSTALL BELL AND SPIGOT PIPE WITH BELL END UPSTREAM. STOPS, REDUCERS, AND ESCUTCHEONS. B. INSTALL TAGS WITH CORROSION RESISTANT CHAIN. 5. MINIMUM NOISE REDUCTION COEFFICIENTS: C. DAMPER OPERATOR: 24 VOLT WITH GEAR TRAIN SEALED IN OL. OF EQUIPMENT. NO ADDITIONAL PAYMENT WILL BE MADE FOR LACK OF CONTRACTOR C. INSTALL PLASTIC PIPE MARKERS IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. a. 1 INCH THICKNESS: 0.45. M. INSTALL VALVES WITH STEMS UPRIGHT OR HORIZONTAL, NOT INVERTED. C. INSTALL COMPONENTS LEVEL AND PLUMB. D. MIXED AIR CONTROLS: MAINTAIN SELECTED SUPPLY AIR TEMPERATURE AND RETURN LL COORDINATION OF ELECTRICAL CHARACTERISTICS. N. INSTALL WATER PIPING TO ASME 831.9. D. INSTALL AND SECURE FIXTURES IN PLACE WITH WALL SUPPORTS AND BOLTS. DAMPERS TO MINIMUM POSITION ON CALL FOR HEATING AND ABOVE 75 DEGREES F 10. ALL MECHANICAL AND ELECTRICAL SYSTEM COMPONENTS SHALL BE ROUTED TIGHT D. INSTALL UNDERGROUND PLASTIC PIPE MARKERS 6 TO 8 INCHES BELOW FINISHED GRADE, B. ADHESIVE: WATERPROOF, FIRE-RETARDANT TYPE. 0. WC PIPE: MAKE SOLVENT-WELDED JOINTS IN ACCORDANCE WITH ASTM D 2855. (DO NOT E SEAL FIXTURES TO WDLL AND FLOOR SURFACES WITH SEALANT. AMBIENT, OR WHEN AMBIENT NR TEMPERATURE EXCEEDS RETURN AIR TEMPERATURE. TO UNDERSIDE OF STRUCTURE AND THROUGH JOISTS OR TRUSSES WHERE DIRECTLY ABOVE BURIED PIPE. C. LINER FASTENERS: GALVANIZED STEEL, SELF-ADHESIVE PAD, IMPACT APPLIED, OR WELDED POSSIBLE. COORDINATE INSTALLATION TO PRESERVE HEADROOM, EQUIPMENT WITH INTEGRAL, OR PRESS-ON HEAD. INSTALL IN RETURN AIR PLENUMS.) F. SOLIDLY ATTACH WATER CLOSETS TO FLOOR WITH UG SCREWS. LEAD FLASHING IS NOT 2.09 OPERATING CONTROLS - SINGLE ZONE UNITS E. USE TAGS ON PIPING 3/4 INCH DIAMETER AND SMALLER. INTENDED HOLD FIXTURE IN PUCE. ACCESS, AND ARCHITECTURAL CLEARANCES FOR FINISHES, INCLUDING CEILING PART 3 EXECUTION P. SLEEVE PIPES PASSING THROUGH PARTITIONS, WALLS AND FLOORS. A ELECTRIC SOLID STATE MICROCOMPUTER BASED ROOM THERMOSTAT WITH REMOTE SENSOR 1. IDENTIFY SERVICE, FLOW DIRECTION, AND PRESSURE. HEIGHTS. COORDINATE WITH ALL OTHER TRADES AND N NOT CONFLICT WITH THE Q. INSERTS: 3.04 INTERFACE WITH WORK OF OTHER SECTIONS LOCATED AS INDICATED. ARCHITECTURAL REQUIREMENTS FOR THE FINISHED CONSTRUCTION. PROVIDE OFFSETS 2. INSTALL IN CLEAR VIEW AND ALIGN WITH AXIS OF PIPING. 3.01 EXAMINATION WHERE REQUIRED TO COORDINATE WITH OTHER TRADES. 3. LOCATE IDENTIFICATION NOT TO EXCEED 20 FEET ON STRAIGHT RUNS INCLUDING RISERS A VERIFY THAT DUCTS HAVE BEEN TESTED BEFORE APPLYING INSULATION MATERIALS. 1. PROVIDE INSERTS FOR PLACEMENT IN CONCRETE FORMWORK. A REVIEW MILLWORK SHOP DRAWINGS. CONFIRM LOCATION AND SIZE OF FIXTURES AND B. ROOM THERMOSTAT SHALL INCORPORATE: 11, REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR LOCATIONS OF ALL AND DROPS, ADJACENT TO EACH VALVE AND TEE, AT EACH SIDE OF PENETRATION OF 2. PROVIDE INSERTS FOR SUSPENDING HANGERS FROM REINFORCED CONCRETE SLABS AND OPENINGS BEFORE ROUGH-IN AND INSTALLATION. 1. AUTOMATIC SWITCHING FROM HEATING TO CONG. GRILLES AND DIFFUSERS. STRUCTURE OR ENCLOSURE, AND AT EACH OBSTRUCTION. B. VERIFY THAT SURFACES ARE CLEAN, FOREIGN MATERIAL REMOVED, AND DRY. OLISIDES OF REINFORCED CONCRETE BEAMS. 3.05 ADJUSTING 2. PREFERENTIAL RATE CONTROL TO MINIMIZE OVERSHOOT AND DEVIATION FROM SET 12. OPERATION AND MAINTENANCE MANUALS: G. LOCATE COILING TACKS TO LOCATE VALVES OR DAMPERS ABOVE LAY-IN PANEL CEILINGS. 3.02 INSTALLATION 3. PROVIDE HOOKED ROD TO CONCRETE REINFORCEMENT SECTION FOR INSERTS CARRYING A ADJUST STOPS OR VALVES FOR INTENDED WATER FLOW RATE 10 FIXTURES WITHOUT POINT. THREE (3) BOUND SETS OF THE OPERATION AND MAINTENANCE MANUALS SHALL BE LOCATE IN CORNER OF PANEL CLOSEST TO EQUIPMENT. A INSTALL IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. PIPE OVER 4 INCHES. SPLASHING, NOISE, OR OVERFLOW. 3. SET-UP FOR FOUR SEPARATE TEMPERATURES PER DAY. PROVIDED TO THE CONSTRUCTION REPRESENTATIVE AT TURNOVER, AND ARE 4. WHERE CONCRETE SLABS FORM FINISHED CEILI3 NG, LOCATE INSERTS FLUSH WITH SLAB 4. INSTANT OVERRIDE OF SET POINT FOR CONTINUOUS OR TIMED PERIOD FROM ONE HOUR REQUIRED FOR FINAL ACCEPTANCE. SECTION 15082 B. INSTALL IN ACCORDANCE WITH NAIMA NATIONAL INSULATION STANDARDS. SURFACE. .06 CLEANING TO 31 DAYS. 13. AS BUILT DRAWINGS: C. INSULATED DUCTS CONVN14C AIR BELOW AMBIENT TEMPERATURE: 5. WHERE INSERTS ARE OMITTED, DRILL THROUGH CONCRETE SLAB FROM BELOW AND A CLEAN PLUMBING FIXTURES AND EQUIPMENT. 5. SHORT CYCLE PROTECTION. THE HVAC SUBCONTRACTOR SHALL PROGRESSIVELY RECORD ALL HVAC DRAWING PIPING INSULATION 1. PROVIDE INSULATION WITH VAPOR BARRIER JACKETS. PROVIDE THROUGH-BOLT WITH RECESSED SQUARE STEEL PLATE AND NUT ABOVE SLAB. 3.07 PROTECTION 6. PROGRAMMING BASED ON WEEKDAYS, SATURDAY AND SUNDAY. asea.sed e.lr.+w...,o..0 of CHANGES WHICH SHALL BE AVAILABLE AT ALL TIMES FOR REVIEW BY THE 2. FINISH WITH TAPE AND VAPOR BARRIER JACKET. muwwmu. eenmo ere "l .e m CONSTRUCTION REPRESENTATIVE. AN AUIOC ALL COPY OF THE FINAL AS-BUILT PART 1 GENERA R. PIPE HANGERS AND SUPPORTS: A PROTECT INSTALLED PRODUCTS FROM DAMAGE DUE TO SUBSEQUENT CONSTRUCTION 7. SWITCH SELECTION FEATURES INCLUDING IMPERIAL OR METRIC DISPLAY, 12 OR 24 .1w.ce"r.m._me wopeny of 3. CONTINUE INSULATION THROUGH WALLS, SLEEVES, HANGERS, AND OTHER DUCT OPERATIONS. HOUR CLOCK, KEYBOARD DISABLE, REMOTE SENSOR, FAN ON-AUTO. fBi`I°s"°'F. "c"1e'"fC1°°c` T,a. DRAWINGS SHALL BE PROVIDED TO THE CONSTRUCTION REPRESENTATIVE AT 1.01 SECTION INCLUDES PENETRATIONS. 1. INSTALL IN ACCORDANCE WITH ASME 831.9. oI Nae d.......o+.sss conevaenon 2. SUPPORT HORIZONTAL PIPING AS PER PIPE MANUFACTURES RECOMMENDATIONS OR AS 8. DO NOT PERMIT USE OF FIXTURES BY CONSTRUCTION PERSONNEL. C. ROOM THERMOSTAT DISPLAY SHALL INCLUDE: ooee onr$fo+Fwed«s an«m..or TURNOVER. THIS AUTOCAD AS-BUILT IS REQUIRED FOR FINAL ACCEPTANCE OF THE A. PIPING INSULATION. 4. INSULATE ENTIRE SYSTEM INCLUDING FITTINGS, JOINTS, FLANGES, FIRE DAMPERS, ss.doc wasc+.emed of m swcoy PROJECT. FLEXIBLE CONNECTIONS, AND EXPANSION JOINTS. SCHEDULED WHICH EVER IS MORE STRINGENT. C. REPAIR OR REPLACE DAMAGED PRODUCTS BEFORE DATE OF SUBSTANTIAL COMPLETION. 1. TIME OF DAY. wdaed.•.�epered+u.Icv..e B. JACKETS AND ACCESSORIES. 3. INSTALL HANGERS TO PROVIDE MINIMUM 1/2 INCH SPACE BETWEEN FINISHED COVERING 2. ACTUAL ROOM TEMPERATURE. or cl.r+oess+F. weft.A,c,Wwl B.CODES, STANDARDS AND REGULATIONS 1.02 RELATED REQUIREMENTS D. EXTERNAL DUCT INSULATION APPLICATION: AND ADJACENT WORK. 3. PROGRAMMED TEMPERATURE. 1. CONFORM TO ALL APPLICABLE CODES, GOVERNMENT REGULATIONS, UTIUTY COMPANY PART 2 PRODUCTS 1. SECURE INSULATION WITH VAPOR BARRIER WITH WIRES AND SEAL JACKET JOINTS WITH 4. PUCE HANGERS WITHIN 12 INCHES OF EACH HORIZONTAL ELBOW. 4. PROGRAMMED TIME. REQUIREMENTS, AND NATIONAL ELECTRICAL CODE. VAPOR BARRIER ADHESIVE OR TAPE TO MATCH JACKET, 5. USE HANGERS WITH 1-1/2 INCH MINIMUM VERTICAL ADJUSTMENT. DESIGN HANGERS 2. OBTAIN PERMITS AND PAY ALL FEES. ARRANGE FOR ALL REQUIRED INSPECTIONS 2.01 REQUIREMENTS FOR ALL PRODUCTS OF THIS SECTION 2. SECURE INSULATION WITHOUT VAPOR BARRIER WITH STAPLES, TAPE, OR WIRES. / SECTION 15430 5. DURATION OF TIMED OVERRIDE. AND APPROVALS. A SURFACE BURNING CHAFNACTERISTICS: FLAME SPREAD SMOKE DEVELOPED INDEX OU 3. INSTALL WITHOUT SAG ON UNDERSIDE OF DUCT. USE ADHESIVE OR MECHANICAL FOR PIPE MOVEMENT WITHOUT DISENGAGEMENT OF SUPPORTED PIPE. 6. DAY OF WEEK. 25/50, MAXIMUM, WHEN TESTED IN ACCORDANCE WITH ASTM E 84, NFPA 255, OR UL FASTENERS WHERE NECESSARY TO PREVENT SAGGING. LIFT DUCT OFF TRAPEZE 6. SUPPORT VERTICAL PIPING AT EVERY FLOOR. SUPPORT RISER PIPING INDEPENDENTLY PLUMBING EQUIPMENT 7. SYSTEM MODEL INDICATION: HEATING, COOLING, AUTO, Off, FAN AUTO, FAN ON. C.RELATED WORK SPECIFIED ELSEWHERE Of CONNECTED HORIZONTAL PIPING. 1. OPENINGS AND CHASES, WHEN SHOWN ON ARCHITECTURAL DRAWINGS. 723" HANGERS AND INSERT SPACERS. PART 1 PRODUCTS 8. STAGE (HEATING OR COOLING) OPERATION. 4. SEAL VAPOR BARRIER PENETRATIONS BY MECHANICAL FASTENERS WITH VAPOR BARRIER 7 WHERE SEVERAL PIPES CAN BE INSTALLED IN PARALLEL AND AT SAME ELEVATION.2.02 GLASS FIBER (THICKNESS SHALL PROVIDE R VALUE REQUIRED BY GOVERNING ENERGY PROVIDE MULTIPLE OR TRAPEZE HANGERS. 1.01 WATER HEATER MANUFACTURERS, AS SCHEDULED ON DRAWINGS OR APPROVED EQUAL. D. PROVIDE LOW LIMIT THERMOSTAT IN SUPPLY AIR TO CLOSE OUTSIDE AIR DAMPERS AND ADHESIVE. STOP SUPPLY FAN. D.DRAWINGS CONSERVATION CODE FOR SPECIFIC APPLICATION) 8. PROVIDE COPPER PLATED HANGERS AND SUPPORTS FOR COPPER PIPING. 1.02 COMMERCIAL ELECTRIC WATER HEATERS 1. THE SYSTEMS AS SHOWN ON THE CONTRACT DRAWINGS ARE DIAGRAMMATIC. A INSULATION: RIGID MOLDED, NONCOMBUSTIBLE. 5. STOP AND POINT INSULATION AROUND ACCESS DOORS AND DAMPER OPERATORS TO 9. PRIME COAT EXPOSED STEEL HANGERS AND SUPPORTS. REFER TO SECTION 09900. PART 3 EXECUTION ALLOW OPERATION WITHOUT DISTURBING WRAPPING. A TYPE: FACTORY-ASSEMBLED AND WIRED, ELECTRIC, INSTANTANEOUS. 2. THE INTENT IS FOR COMPLETE AND WORKABLE SYSTEMS. THE DRAWINGS AND THESE 1. 'K' VALUE 0.24 AT 75 DEGREES F. HANGERS AND SUPPORTS LOCATED IN CRAWL SPACES, PIPE SHAFTS, AND SUSPENDED 3.01 EXAMINATION NOTES ARE TO BE USED TOGETHER AS A BASIS OF SHOWING AND/OR DESCRIBING E. DUCT AND PLENUM LINER APPLICATION: CEILING SPACES ARE NOT CONSIDERED EXPOSED. B. PERFORMANCE AND ELECTRICAL CHARACTERISTICS, AS SCHEDULED ON DRAWINGS. 2. MAXIMUM SERVICE TEMPERATURE 850 DEGREES F. A VERIFY THAT ROOF IS READY TO RECEIVE WORK AND OPENING DIMENSIONS ARE AS THE SYSTEM REQUIREMENTS FOR THE FACILITY i. ADHERE INSULATION WITH ADHESIVE FOR 90 PERCENT COVERAGE. tO.SUPPORT CAST IRON DRAINAGE PIPING AT EVERY JOINT. C. CONTROLS: EXTERNALLY ADJUSTABLE TEMPERATURE RANGE FROM 60 TO 140 DEGREES F. INDICATED ON SHOP DRAWINGS. 1 VERIFY ALL DIMENSIONS AND CLEARANCES BY FIELD MEASUREMENT AND CHECK FOR 3. MAXIMUM MOISTURE ABSORPTION: 0.2 PERCENT BY VOLUME. 2. SECURE INSULATION WITH MECHANICAL UNER FASTENERS. REFER TO SMACNA HVAC 3.04 APPLICATION NICHROME HEATING COILS, HIGH TEMPERATURE LIMIT THERMOSTAT. INTERFERENCES PRIOR TO STARTING WORK. B. VAPOR BARRIER JACKET: WHITE KRAFT PAPER WITH GLASS FIBER YARN, BONDED TO DUCT CONSTRUCTION STANDARDS - METAL AND FLEXIBLE FOR SPACING. D. ACCESSORIES: PROVIDE: B. VERIFY THAT PROPER POWER SUPPLY IS AVAILABLE. A USE GROOVED MECHANICAL COUPLINGS AND FASTENERS ONLY IN ACCESSIBLE LOCATIONS. ALUMINIZED FILM; MOISTURE VAPOR TRANSMISSION WHEN TESTED IN ACCORDANCE WITH 3. SEAL AND SMOOTH JOINTS. SEAL AND COAT TRANSVERSE JOINTS. 1. WATER CONNECTIONS: COMPRESSION FITTINGS. 3.02 INSTALLATION E BASE EQUIPMENT AND MATERIALS AND SUBSTITUTIONS 0.02 PERM-INCHES. 4. SEAL LINER SURFACE PENETRATIONS AND EDGES WITH ADHESIVE. B. INSTALL UNIONS DOWNSTREAM OF VALVES AND AT EQUIPMENT OR APPARATUS 2. TEMPERATURE AND PRESSURE RELIEF VALVE: ASME LABELLED. A INSTALL IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. 1. ALL EQUIPMENT AND MATERIALS SHALL BE NEW, FREE OF DEFECTS AND ILL. 2.03 JACKETS 5. DUCT DIMENSIONS INDICATED ARE NET INSIDE DIMENSIONS REQUIRED FOR AIR FLOW. CONNECTIONS. F. HEATING ELEMENTS: FLANGE-MOUNTED IMMERSION ELEMENTS; INDIVIDUAL ELEMENTS B. MOUNT UNITS ON FACTORY BUILT ROOF MOUNTING CURB PROVIDING WATERTIGHT LABELED. A PVC PLASTIC. INCREASE DUCT SIZE i0 ALLOW FOR INSULATION THICKNESS. C. INSTALL HALL VALVES FOR SHUT-OFT AND TO ISOLATE EQUIPMENT, PART OF SYSTEMS, OR SHEATHED WITH INCOLOY CORROSION-RESISTANT METAL ALLOY, RATED LESS THAN 75 ENCLOSURE TO PROTECT DUCTWORK AND UTILITY SERVICES. INSTALL ROOF MOUNTING 2. SUBMIT SHOP DRAWINGS FOR ALL EQUIPMENT, FIXTURES, ETC., INCLUDING ALL ACCESSORIES TO BE FURNISHED. BASE BID MANUFACTURERS AND MODELS ARE I. JACKET: ONE PIECE MOLDED TYPE FITTING COVERS AND SHEET MATERIA, OFF-WHITE 3.03 SCHEDUVERTICAL RISERS.LES WATTS PER SQUARE INCH. CURB LEVEL INCLUDED IN SPECIFICATIONS OR LISTED IN SCHEDULE ON DRAWING. ANY OTHER COLOR. A SUPPLY AIR DUCT AND TO SIDE OF DIFFUSERS: D. INSTALL BALL VALVES FOR THROTTLING, BYPASS, OR MANUAL FLOW CONTROL SERVICES. PART 3 EXECUTION C. LOCATE REMOTE PANELS WHERE INDICATED ON DRAWINGS. MANUFACTURER OR MODEL IS A SUBSTITUTION. a. MINIMUM SERVICE TEMPERATURE: 0 DEGREES F. 1. RIGID CLASS FIBER DUCT LINER: 1 INCHES THICK WITHIN 10 FEET OF AC UNITS. E. PROVIDE UL LISTED BALL VALVES IN NATURAL GAS SYSTEMS. 2.01 INSTALLATION 3.03 SYSTEM STARTUP 3. SUBSTITUTIONS ARE SUBJECT TO THE APPROVAL OF THE OWNER AND SHALL BE b. MAXIMUM SERVICE TEMPERATURE: 150 DEGREES E 2. FLEXIBLE GLASS FIBER DUCT WRAP INSULATION: 1-1/2 INCHES THICK ON ALL OTHER. F. PROVIDE FLOW CONTROLS AND CHECK VALVES IN WATER RECIRCULATING SYSTEMS WHERE LISTED ON THE FORM OF PROPOSAL FOR THE OW'NER'S CONSIDERATION PRIOR TO c. MOISTURE VAPOR PERMEABILITY: 0.002 PERM INCH, MAXIMUM. INDICATED. A INSTALL PLUMBING EQUIPMENT IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS, AS A PREPARE AND STMT EQUIPMENT. ADJUST FOR PROPER OPERATION. CONTRACT AWARD. If SUBSTITUTION IS SUBMITTED, IT IS THE CONTRACTOR'S B. RETURN AIR DUCT: REQUIRED BY CODE, AND COMPLYING WITH CONDITIONS OF CERTIFICATION, IF ANY. d. THICKNESS: 10 MIL. 3.05 TOLERANCES 3.04 CLOSEOUT ACTIVITIES RESPONSIBILITY TO EVALUATE IT AND CERTIFY THAT THE SUBSTITUTION IS 1. RIGID GLASS FIBER DUCT LINER: 1 INCHES THICK WITHIN 10 FEET OF AC UNITS. B. COORDINATE WITH PLUMBING PIPING AND RELATED FUEL PIPING WORK TO ACHIEVE EQUIVALENT IN ALL RESPECTS TO THE BASE SPECIFICATIONS. e. CONNECTIONS: BRUSH ON WELDING ADHESIVE. A. DRAINAGE PIPING ESTABLISH INVERT ELEVATIONS WITHIN 1/2 INCH VERTICALLY OF OPERATING SYSTEM. A DEMONSTRATE OPERATION TO OWNER'S MAINTENANCE PERSONNEL. 4. IF SUBSTITUTIONS ARE APPROVED, NOTIFY ALL OTHER CONTRACTORS, PMT 3 EXECUTION SECTION 15145 LOCATION INDICATED AND SLOPE TO DRAIN AT MINIMUM OF 1/8 INCH PER FOOT SLOPE. 3.05 MAINTENANCE SUBCONTRACTORS OR TRADES AFFECTED BY SUBSTITUTION AND FULLY COORDINATE. 3.01 EXAMINATION B. WATER PIPING: SLOPE AT MINIMUM OF 1/32 INCH PER FOOT AND ARRANGE TO DRAIN AT SECTION 15735 A PROVIDE A SEPARATE MAINTENANCE CONTRACT FOR SPECIFIED MAINTENANCE SERVICE. ANY COSTS RESULTING FROM SUBSTITUTION, WHETHER BY CONTRACTOR OR OTHERS, C. VERIFY THAT PIPING HAS BEEN TESTED BEFORE APPLYING INSULATION MATERIALS. PLUMBING PIPING LOW POINTS. B. PROVIDE SERVICE AND MAINTENANCE OF PACKAGED ROOF TOP UNITS FOR ONE YEAR YEAR SHALL BE RESPONSIBILITY OF AND PAID FOR BY SUBSTITUTING CONTRACTOR. PART 1 GENERALFROM DATE OF SUBSTANTIAL COMPLETION. 5. ALL EQUIPMENT SHALL BE INSTALLED IN FULL ACCORDANCE WITH THE D. VERIFY THAT SURFACES ARE CLEAN AND DRY, WITH FOREIGN MATERIAL REMOVED. 1.01 SECTION INCLUDES ION 3.06 DISINFECTOF DOMESTIC WATER PIPING SYSTEM PACKAGED ROOF TOP AIR CONDITIONING UNITS MANUFACTURER'S INSTALLATION INSTRUCTIONS. IT IS THIS CONTRACTOR'S 3.02 INSTALLATION A DISINFECT WATER DISTRIBUTION SYSTEM AFTER INSTALLATION. ONE GALLON 5% CHLOROX PMT i GENERAL C. PROVIDE ROUTINE MAINTENANCE SERVICE WITH A TWO MONTH INTERVAL AS MAXIMUM TIME RESPONSIBILITY TO CHECK AND CONFORM TO THESE REQUIREMENTS PRIOR TOA. PIPE, PIPE FITTINGS, VALVES, AND CONNECTIONS FOR PIPING SYSTEMS. PER 300 GALLONS SYSTEM VOLUME OR DISINFECT AS PROVIDED UNDER AWWA STANDARD 1.01 SECTION INCLUDES PERIOD BETWEEN CALLS. A INSTALL IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. 1. SANITARY SEWER AND VENT. C651-85 WITH 24 HOUR APPLICATION TIME PERIOD. STATING WORK. B. INSTALL IN ACCORDANCE WITH NAIMA NATIONAL INSULATION STANDARDS. A PACKAGED ROOF TOP UNIT. D. INCLUDE MAINTENANCE ITEMS AS OUTLINED IN MANUFACTURER'S OPERATING AND 2. DOMESTIC WATER. B. PRIOR TO STATING WORK, VERIFY SYSTEM IS COMPLETE, FLUSHED AND CLEAN. MAINTENANCE DATA, INCLUDING MINIMUM OF 7W0 FILTER REPLACEMENTS, MINIMUM Of ONE F. CHECK, TEST, START, ADJUST, BALANCE AND INSTRUCTIONS C. EXPOSED PIPING: LOCATE INSULATION AND COVER SEAMS IN LUST VISIBLE LOCATIONS. 1.02 SUBMITTALS 3.07 SCHEDULES B. UNIT CONTROLS. FAN BELT REPLACEMENT, AND CONTROLS CHECK-OUT, ADJUSTMENTS, AND RECALIBRATION. 1. AFTER INSTALLATION, CHECK ALL EQUIPMENT, AND PERFORM START UP IN D. INSULATED PIPES CONVEYING FLUIDS BELOW AMBIENT TEMPERATURE: INSULATE ENTIRE A PROJECT RECORD DOCUMENTS: RECORD ACTUAL LOCATIONS OF VANES. A PIPE HANGER SPACING: C. REMOTE PANEL. ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. E. PROVIDE 24-HOUR EMERGENCY SERVICE ON BREAKDOWNS AND MALFUNCTIONS. SYSTEM INCLUDING FITTINGS, VALVES, UNIONS, FLANGES, STRAINERS, FLEXIBLE D. ROOF MOUNTING CURB AND BASE. 2. ALL PIPING SHALL BE TESTED AND FREE OF LEAKS. CONNECTIONS, PUMP BODIES, AND EXPANSION JOINTS. 1.03 QUALITY ASSURANCE 1. META PIPING: F. AFTER EACH SERVICE CALL SUBMIT COPY Of SERVICE CALL WORK ORDER OR REPORT 3. BALANCE ALL SYSTEMS, CALIBRATE CONTROLS, CHECK FOR PROPER OPERATING E. GLASS FIBER INSULATED PIPES CONVEYING FLUIDS BELOW AMBIENT TEMPERATURE: 1. PERFORM WORK IN ACCORDANCE WITH CURRENT LOCAL GOVERNING PLUMBING CODE a. PIPE SIZE: 1/2 INCHES TO 1-1/4 INCHES: 1.02 SUBMITTALS THAT INCLUDES DESCRIPTION OF WORK PERFORMED. SEQUENCE UNDER ALL CONDITIONS, AND MAKE ALL NECESSARY ADJUSTMENTS. 2. MAINTAIN ONE COPY ON PROJECT SITE. 1) MAXIMUM NIGER SPACING: 6.5 FT. A PRODUCT DATA: PROVIDE CAPACITY PER DRAWING SCHEDULE AND DIMENSIONS OF SECTION 15810 4. ALL WIRING SHALL BE FULLY TESTED AND MADE FREE OF GROUNDS AND SHORT 1. PROVIDE VAPOR BARRIER JACKETS, FACTORY-APPLIED OR FIELD-APPLIED. SECURE MANUFACTURED PRODUCTS AND ASSEMBLIES REQUIRED FOR THIS PROTECT. INDICATE CIRCUITS. WITH SELF-SEALING LONGITUDINAL LMS AND BUTT STRIPS WITH PRESSURE SENSITIVE B. VALVES: MANUFACTURER'S NAME AND PRESSURE RATING MARKED ON VALVE BODY. 2)HANGER ROD DIAMETER: 3/8 INCHES, ELECTRICAL SERVICE WITH ELECTRICAL CHARACTERISTICS AND CONNECTION REQUIREMENTS, 5. INSTRUCT OWNER IN OPERATION OF SYSTEMS AND SUBMIT OPERATING AND ADHESIVE. SECURE WITH OUTWARD CONCH EXPANDING STAPLES AND VAPOR BARRIER C. WELDING MATERIALS AND PROCEDURES: CONFORM TO ASME (BPL IX) AND APPLICABLE b. PIPE SIZE: 1-1/2 INCHES TO 2 INCHES: AND DUCT CONNECTIONS. DUCTWORK MAINTENANCE MANUAL ON ALL EQUIPMENT AND SYSTEMS. MASTIC. STATE LABOR REGULATIONS. 1) MAXIMUM HANGER SPACING: 10 FT. 6. PROVIDE ENGRAVED LABELS AND IDENTIFICATION TAGS FOR ALL PIPING SYSTEMS, 2. INSULATE FITTINGS, JOINTS, AND VALVES WITH MOLDED INSULATION OF UKE MATERIAL B. SHOP DRAWINGS: INDICATE CAPACITY AND DIMENSIONS OF MANUFACTURED PRODUCTS AND PMT 1 GENERA 2)DANCER R00 DIAMETER: 3/8 INCH. ASSEMBLIES REQUIRED FOR THIS PROJECT. INDICATE ELECTRICAL SERVICE WITH 1.01 SECTION INCLUDES VALVES AND EQUIPMENT. AND THICKNESS AS ADJACENT PIPE. FINISH WITH GLASS CLOTH AND VAPOR BARRIER D. WELDER QUALIFICATIONS: CERTIFIED IN ACCORDANCE WITH ASME (BPV IX). 7. PROVIDE TYPED PANEL DIRECTORIES AND ENGRAVED LABELS FOR ALL PANELS AND ADHESIVE OR PVC FITTING COVERS. E. IDENTIFY PIPE WITH MARKING INCLUDING SIZE, ASTM MATERIAL CLASSIFICATION, ASTM c. PIPE SIZE: 2-1/2 INCHES TO 3 INCHES: ELECTRICAL CHARACTERISTICS AND CONNECTION REQUIREMENTS, AND DUCT CONNECTIONS. A METAL DUCTWORK. EQUIPMENT. F. FOR HOT PIPING CONVEYING FLUIDS 140 DEGREES F OR LESS, DO NOT INSULATE SPECIFICATION, POTABLE WATER CERTIFICATION, WATER PRESSURE RATING. 1) MAXIMUM HANGER SPACING: 10 FT. C. MANUFACTURER'S INSTRUCTIONS: INDICATE ASSEMBLY, SUPPORT DETAILS, CONNECTION B. NONMETAL DUCTWORK. FLANGES AND UNIONS AT EQUIPMENT, BUT BEVEL AND SEAL ENDS OF INSULATION. 1.04 REGULATORY REQUIREMENTS 2)HANGER ROD DIAMETER: 1/2 INCH. REQUIREMENTS, AND INCLUDE START-UP INSTRUCTIONS. C. CASING AND PLENUMS. G CUTTING, PATCHING AND DRILLING G. GLASS FIBER INSULATED PIPES CONVEYING FLUIDS ABOVE AMBIENT TEMPERATURE: A PERFORM WORK IN ACCORDANCE WITH CURRENT LOCAL GOVERNING PLUMBING CODE. d. PIPE SIZE: 4 INCHES TO 6 INCHES: D. OPERATION AND MAINTENANCE DATA INCLUDE MANUFACTURER'S DESCRIPTIVE LITERATURE, 1. ALL CUTTING AND CHASING OF THE BUILDING CONSTRUCTION REQUIRED FOR THIS D. DUCT CLEANING. WORK SHALL BE BY THIS CONTRACTOR UNLESS SHOWN ON ARCHITECTURAL I. PROVIDE STANDARD JACKETS, WITH OR WITHOUT VAPOR BARRIER, FACTORY-APPLIED OR B. CONFORM TO APPLICABLE CODE FOR INSTALLATION OF BACKFLOW PREVENTION DEVICES. 1) MAXIMUM HANGER SPACING: 10 FT. OPERATING INSTRUCTIONS, INSTALLATION INSTRUCTIONS, MAINTENANCE AND REPAIR DATA, DRAWINGS AND CONFIRMED AS TO SIZE AND LOCATION PRIOR TO NEW FIELD-APPLIED. SECURE WITH SELF-SEALING LONGITUDINAL UPS AND BUTT STRIPS C. PROVIDE CERTIFICATE Of COMPLIANCE FROM AUTHORITY HAVING JURISDICTION INDICATING 2)HANGER ROD DIAMETER: 5/8 INCH. AND PARTS LISTING. PART 2 PRODUCTS CONSTRUCTION. CUTTING SHALL BE IN A NEAT AND WORKMANLIKE MANNER. WITH PRESSURE SENSITIVE ADHESIVE. SECURE WITH OUTWARD CLINCH EXPANDING APPROVAL OF INSTALIAIION OF BACKFLOW PREVENTION DEVICES. 2. PLASTIC PIPING: E. WARRANTY: SUBMIT MANUFACTURER'S WARRANTY AND ENSURE FORMS HAVE BEEN FILLED 2.01 DUCT ASSEMBUES 2 NEATLY SAW CUT ALL RECTANGULAR OPENINGS, SET SLEEVE THROUGH OPENING, STAPLES. 1.05 DELIVERY, STORAGE, AND HANDLING I. ALL SIZES: OUT IN OWNER'S NAME AND REGISTERED WITH MANUFACTURER. A ALL DUCTS: GALVANIZED STEEL, UNLESS OTHERWISE INDICATED. AND FINISH PATCH OR PROVIDE TRIM FLANGE AROUND OPENING. 2. INSULATE FITTINGS, JOINTS, AND VALVES WITH INSULATION OF LIKE MATERIAL AND 1)MAXIMUM HANGER SPACING: 6 FT. F. MAINTENANCE MATERIALS: FURNISH THE FOLLOWING FOR OWNER'S USE IN MAINTENANCE 8. LOW PRESSURE SUPPLY: 2 INCH W.G. PRESSURE CLASS, GALVANIZED STEEL 3. NEATLY SAW CUT FLOORS FOR SEWER INSTALLATION AND PATCH FLOOR TO MATCH THICKNESS AS ADJOINING PIPE. FINISH WITH GLASS CLOTH AND ADHESIVE OR PVC A. ACCEPT VALVES ON SITE IN SHIPPING CONTAINERS WITH LABELING IN PLACE. INSPECT EXISTING, INCLUDING FLOOR COVERING. FITTING COVERS. FOR DAMAGE. 2)HANGER ROD DIAMETER: 3/8 INCH. OF PROJECT. 2 SETS OF FILTERS PER DRAWING SCHEDULE. G RETURN AND RELIEF: 2 INCH W.G. PRESSURE CLASS, GALVANIZED STEEL. 4. CORE DRILL AND SLEEVE ALL ROUND OPENINGS. 1.03 QUALITY ASSURANCE H. INSERTS AND SHIELDS: B. PROVIDE TEMPORARY PROTECTIVE COATING ON CAST IRON AND STEEL VALVES. D. GENERAL EXHAUST: 2 INCH W.C. PRESSURE CLASS, GALVANIZED STEEL. SECTION 15146 I WALLS A R T INSTALLATION. A MANUFACTURER QUALIFICATIONS: COMPANY IN MANUFACTURING THE TYPE 5. CUT AND PATCH EXISTING BUILDING S REQUIRED FOR DUC INS 1. ARPLICATION: PIPING 1-i/2 INCHES DIAMETER OR LARGER. C. PROVIDE TEMPORARY END CAPS AND CLOSURES ON PIPING AND FIRINGS. MAINTAIN IN W SPECIALIZING E E OF E. OUTSIDE AIR INTAKE: 2 INCH W.G. PRESSURE CLASS, GALVANIZED STEEL PROVIDE STEEL LINTEL ABOVE OPENING WIDER THAN 10'. SEE STRUCTURAL PUCE UNTIL INSTALLATION. PRODUCTS SPECIFIED IN THIS SECTION, WITH MINIMUM THREE YEARS OF DOCUMENTED DRAWINGS FOR SIZES. PROVIDE ESCUTCHEONS OR 2' WIDE SHEET METAL FLANGES 2. SHIELDS: GALVANIZED STEEL BETWEEN PIPE HANGERS OR PIPE HANGER ROLLS AND PLUMBING SPECIALTIES EXPERIENCE. F. TRANSFER AIR AND SOUND BOOTS: 2 INCH W.G. PRESSURE CLASS, GALVANIZED STEEL. MOUND ALL EXPOSED PENETRATIONS. INSERTS. D. PROTECT PIPING SYSTEMS FROM ENTRY OF FOREIGN MATERIALS BY TEMPORARY COVERS, PART 1 GENERAL B. PRODUCTS REQUIRING ELECTRICAL CONNECTION: LISTED AND CLASSIFIED BY 2.02 MATERIALS TURAL 3. INSERT LOCATION: BETWEEN SUPPORT SHIELD AND PIPING AND UNDER THE FINISH COMPLETING SECTIONS OF THE WORK, AND ISOLATING PARTS Of COMPLETED SYSTEM. 6. 00 NOT CUT ANY STRUCTURAL COMPONENTS WITHOUT ARCHITECT'S APPROVAL. JACKET 1 O6 FIELD CONDITIONS 1.01 SECTION INCLUDES UNDERWRITERS LABORATORIES INC. AS SUITABLE FOR THE PURPOSE SPECIFIED AND A GALVANIZED STEEL FOR DUCTS: HOT-DIPPED GALVANIZED STEEL SHEET, ASTM A 653/A 7. PATCH AND FINISH TO MATCH ADJACENT AREAS THAT HAVE BEEN CUT, DAMAGED OR 4. INSERT CONFIGURATION: MINIMUM 6 INCHES LONG, OF SAME THICKNESS AND CONTOUR A FLOOR DRAINS. INDICATED. 653M FS TYPE B, WITH G6O/Z780 COATING. MODIFIED TO INSTALL EQUIPMENT FOR THIS PROJECT. A DO NOT INSTALL UNDERGROUND PIPING WHEN BEDDING IS WET OR FROZEN. 1.04 DELIVERY, STORAGE, AND HANDLING 8. CUTTING OF ROOF, INSTALLATION OF CURBS, AND PATCHING OF ROOF SHALL BE BY AS ADJOINING INSULATION; MAY BE FACTORY FABRICATED. B. CLEANOUTS. B. ALUMINUM FOR DUCTS: ASTM B 209 (ASTM B 209M); ALUMINUM SHEET, ALLOY A CERTIFIED ROOFING CONTRACTOR, APPROVED BY BUILDING OWNER, AND PAID FOR 5. INSERT MATERIAL: HYDROUS CALCIUM SIUCATE INSULATION OR OTHER HEAVY DENSITY PART 2 PRODUCTS A PROTECT UNITS FROM PHYSICAL DAMAGE BY STORING OFF SITE UNTIL ROOF MOUNTING 3003-HI4. ALUMINUM CONNECTORS AND BAR STOCK: ALLOY 6061-1651 OR OF w' C. WATER HAMMER ARRESTORS. Y/ BY THIS CONTRACTOR. INSULATING MATERIAL SUITABLE FOR THE PLANNED TEMPERATURE RANGE. 2.01 SANITARY SEWER PIPING, BURIED WITHIN 5 FEET OF BUILDING CURBS ARE IN PUCE, READY FOR IMMEDIATE INSTALLATION OF UNITS. EQUIVALENT STRENGTH. 9. FIRE STOP ALL PENETRATIONS Of FIRE RATED CONSTRUCTION IN A CODE APPROVED L CONTINUE INSULATION THROUGH WALLS, SLEEVES, PIPE HANGERS, AND OTHER PIPE A D. WASH MACHINE UTILITY BOXES CAST IRON PIPE: HUB AND SPIGOT 1.05 WARRANTY C. STAINLESS STEEL FOR DUCTS: ASTM A 240/A 240M, TYPE 304. u MANNER, USING UL LISTED FIRE RATED MATERIALS. PENETRATIONS. FINISH AT SUPPORTS, PROTRUSIONS, AND INTERRUPTIONS. AT FIRE t, FITTINGS: CAST IRON. PART 2 PRODUCTS A PROVIDE A FIVE YEAR WARRANTY TO INCLUDE COVERAGE FOR REFRIGERATION D. JOINT SEALERS AND SEALANTS: NON-HARDENING, WATER RESISTANT, MILDEW AND MOLD o 10. ALL CONTRACTORS SHALL CONFIRM WITH OWNER, PRIOR TO BID, TIMES AVAILABLE SEPARATIONS. 2. JOINTS: COMPRESSION GASKETS CONFORMING TO ASTM 564 2.01 DRAINS COMPRESSORS. RESISTANT. r.! V7 FOR NOISE PRODUCING WORK SUCH AS CUTTING AND CORE DRILLING OF FLOORS, J. PIPE EXPOSED IN MECHANICAL EQUIPMENT ROOMS OR FINISHED SPACES (LESS THAN 10 B. PVC-DWV PLASTIC ASTM D-2665 LATH ASTM D-2665 OW SOLVENT WELD SOCKET FIRINGS. D. FLOOR DRAIN (FD-1): B. PROVIDE A TEN YEAR WARRANTY FOR HEAT EXCHANGER. 1. TYPE: HEAVY MASTIC OR LIQUID USED ALONE OR WITH TME, SUITABLE FOR JOINT w WALLS, ETC., AS WELL AS HARES FOR WORK WHICH REQUIRE ACCESS INTO FEET ABOVE FINISHED FLOOR WHERE SUBJECT TO DAMAGE: FINISH WITH PVC JACKET CONFIGURATION AND COMPATIBLE WITH SUBSTRATES, AND RECOMMENDED BY t ADJOINING MEAS. INCLUDE ANY PREMIUM TIME REQUIRED M 810. ) 2.02 SANITARY SEWER AND VENT PIPING, ABOVE GRADE L LACQUERED CAST IRON TWO PIECE BODY WITH DOUBLE DRAINAGE FLANGE, WEEP PMT 2 PRODUCTS 11. EXACT LOCATION OF ROOF TOP MECHANICAL UNITS SHALL BE APPROVED BY AND FITTING COVERS. A GST IRON PIPE: HUBLESS, SERVICE WEIGHT. HOLES, REVERSIBLE CLAMPING COLLAR, ROUND, ADJUSTABLE NICKEL-BRONZE STRAINER MANUFACTURER FOR PRESSURE CLASS OF DUCTS. MW y 2.01 MANUFACTURERS, AS SCHEDULED ON DRAWINGS OR APPROVED EQUAL. OWNER'S STRUCTURAL ENGINEER. MECHANICAL CONTRACTOR SHALL FURNISH AND K. BURIED PIPING: PROVIDE FACTORY FABRICATED ASSEMBLY WITH INNER ALL-PURPOSE 1. FITTINGS: CAST IRON. AND TRAP PRIMER CONNECTION. 2. VOC CONTENT: NOT MORE THAN 250 G/L EXCLUDING WATER. INSTALL ALL SUPPLEMENTAL SUPPORT STEEL FOR UNITS AND ROOF DUCT SERVICE JACKET WITH SELF-SEALING LAP, AND ASPHALT IMPREGNATED OPEN MESH GLASS 2. JOINTS: NEOPRENE GASKETS AND STAINLESS STEEL CLAMP-AND-SHIELD ASSEMBLIES. 2.02 CLEANOUTS 2.02 AIR CONDITIONING UNITS 3. SURFACE BURNING CHARACTERISTICS: FUME SPREAD OF ZERO, SMOKE DEVELOPED OF = Z W PENETRATIONS AFTER APPROVAL OF STRUCTURAL ENGINEER. FABRIC, WITH ONE MIL THICK ALUMINUM FOIL SANDWICHED BETWEEN THREE LAYERS OF A GENERAL: ROOF MOUNTED UNITS HAVING ELECTRIC REFRIGERATION. ZERO, WHEN TESTED IN ACCORDANCE WITH ASTM E 84. H W W BITUMINOUS COMPOUND; OUTER SURFACE FACED WITH A POLYESTER FILM. B. PJC PIPE: (WHERE ACCEPTABLE IN GOVERNING PLUMBING CODE) C. CLFANOUTS AT INTERIOR FINISHED FLOOR AREAS (CO-1) B. DESCRIPTION: SELF-CONTAINED, PACKAGED, FACTORY ASSEMBLED AND PREWIRED, E. HANGER ROD: ASTM A 36/A 36M; STEEL GALVANIZED; THREADED BOTH ENDS, THREADED tt``�� J LU � � H.WARRANTY 3.03 SCHEDULES 1. FITTINGS: PVC. 1. LACQUERED CAST IRON BODY WITH ANCHOR FLANGE, REVERSIBLE CLAMPING COLLAR, T Q W F- Ny THREADED TOP ASSEMBLY, AND ROUND CJSKLTED SCORED COVER IN SERVICE MUS CONSISTING OF CABINET AND FRAME, SUPPLY TAN, HEAT EXCHANGER, CONTROLS, AIR ONE END, OR CONTINUOUSLY THREADED. •� > NA c'I t. FULLY WARRANT ALL MATERIALS, EQUIPMENT AND WORKMANSHIP FOR ONE (1) YEAR A PLUMBING SYSTEMS: 2. JOINTS: SOLVENT WELDED, WITH SOLVENT CEMENT. FILTERS, REFRIGERANT COOLING COIL AND COMPRESSOR, CONDENSER COIL AND W Q n FROM DATE Of ACCEPTANCE. AND ROUND GASKETED DEPRESSED COVER TO ACCEPT FLOOR FINISH IN FINISHED 2.03 DUCTWORK FABRICATION J = ¢ Y rn 1. DOMESTIC HOT AND COLD WATER SUPPLY: 2.03 WATER PIPING, BURIED WITHIN 5 FEET OF BUILDING FLOOR AREAS CONDENSER FAN. A FABRICATE AND SUPPORT IN ACCORDANCE WITH SMACNA HVAC DUCT CONSTRUCTION CL Q Q 2. EXTEND ALL MANUFACTURER'S WARRANTIES C OWNER, INCLUDING ENE TY YEAR a. GLASS FIBER INSULATION: A COPPER PIPE: ANNEALED. C ELECTRICAL CHARACTERISTICS: AS SCHEDULED ON DRAWINGS 2 0 COMPRESSOR AND TEN (10) YEAR HEAT EXCHANGER EXTENDED WARRANTY ON HVAC D. CLEANOUTS AT INTERIOR FINISHED WALL AREAS (CO-2): STANDARDS - METAL AND FLEXIBLE, AND AS INDICATED. O 1) PIPE SIZE RANGE: 1/2-3 INCH. 1. FITTINGS: CAST COPPER ALLOY OR WROUGHT COPPER AND BRONZE. 1. REFER TO ELECTRICAL DRAWINGS/SPECIFICATIONS. EQUIPMENT. 1. LINE TYPE WITH LACQUERED CAST IRON BODY AND ROUND EPDXY COATED GASIFIED B. NO VARIATION OF DAC? CONFIGURATION OR SIZE PERMITTED EXCEPT BY WRITTEN H 3 p' 3. REPAIR OR REPLACE WITHOUT CHARGE TO THE OWNER ALL ITEMS FOUND DEFECTIVE 2)THICKNESS: 1/2 INCH. 2. JOINTS: ALLOY SN95 SOLDER. COVER, AND ROUND STAINLESS STEEL ACCESS COVER SECURED WITH MACHINE SCREW. D. DISCONNECT SWITCH: FACTORY MOUNT DISCONNECT SWITCH IN CONTROL PANEL. PERMISSION. SIZE ROUND DUCT INSTALLED IN PLACE OF RECTANGULAR DUCTS IN Z 2 DURING THE WARRANTY PERIOD. 2. PLUMBING VENTS WITHIN 10 FEET OF THE EXTERIOR: 2.04 WATER PIPING, ABOVE GRADE 2.03 REFRIGERATOR VALVE AND RECESSED BOX E. PROVIDE HACR CIRCUIT BREAKER IN POWER CONNECTION ACCORDANCE WITH ASHRAE HANDBOOK - FUNDAMENTALS. Z SECTION 15015 SECTION 15086 A COPPER TUBE: TYPE L (B), DRAWN (H). A BOX MANUFACTURERS: 2.03 FABRICATION C. DUCT SYSTEMS HAVE BEEN DESIGNED FOR METAL DUCT. FIBROUS GLASS DUCT MAY NOT '1 F 1. FITTINGS: CAST COPPER ALLOY OR WROUGHT COPPER AND BRONZE. 1. IPS CORPORATION ATER-TATE; WWWJPSCORP.COM. BE SUBSTITUTED FOR METAL DUCT. MECHANICAL IDENTIFICATION 2. JOINTS: ALLOY SN95 SOLDER. �' A CABINET: STEEL WITH BAKED ENAMEL FINISH, INCLUDING ACCESS PANELS WITH DUCT INSULATION 2. OATEY; WWW.OATEY.COM. SCREWDRIVER OPERATED FLUSH CAM TYPE FASTENERS. STRUCTURAL MEMBERS SHALL BE D. PROVIDE DUCT MATERA, GAGES, REINFORCING, AND SEALING FOR OPERATING PRESSURES PART I GENERAL PMT 1 GENERAL B. NAVE MANUFACTURERS:2.05 FLANGES, UNIONS, AND COUPUNGS MINIMUM 18 GAGE, WITH ACCESS DOORS OR PANELS OF MINIMUM 20 GAGE. INDICATED. Pf*d FAIL 1576 1.01 SECTION INCLUDES A. UNIONS FOR PIPE SIZES 3 INCHES AND UNDER: 1. IPS CORPORATION/WATER-TITE; WWW.IPSCORP.COM. B. INSULATION: ONE INCH THICK NEOPRENE COATED GLASS FIBER WITH EDGES PROTECTED E CONSTRUCT T'S, BENDS, AND ELBOWS WITH RADIUS OF NOT LESS THAN 1-1/2 TIMES affm or. Jpu 1.01 SECTION INCLUDES 1. FERROUS PIPE: CLASS 150 MALLEABLE IRON THREADED UNIONS. FROM EROSION. WIDTH OF DUCT ON CENTERLINE. WHERE NOT POSSIBLE, RECTANGULAR ELBOWS MUST A NAMEPLATES' 0. DUCT INSULATION. 2. COPPER TUBE AND PIPE: CLASS 150 BRONZE UNIONS WITH SOLDERED JOINTS. 2. GRIPURN INDUSTRIES, INC; FORMEWWW.ZRN.COM. BE USED. IN RECTANGULAR ELBOWS PROVIDE AIR FOIL TURNING VANES OF PERFORATED B. TAGS. C. DESCRIPTION: PLASTIC PREFORMED ROUGH-IN BOX WITH BRASS NAVES WITH WHEEL C. HEAT EXCHANGERS: ALUMINIZED STEEL, OF WELDED CONSTRUCTION. 0•b Ire B. DUCT LINER. B. FLANGES FOR PIPE SIZE OVER 3 INCH OR URGER: METAL WITH GRASS FIBER INSULATION. $ C. PIPE MARKERS. HANDLE, SLIP IN FINISHING COVER. D. SUPPLY FAN: FORWARD CURVED CENTRIFUGAL TYPE, RESNENRY MOUNTED WfTH V-BELT 0710I ewerrrR 1.02 SUBMITTALS 1. FERROUS PIPE: CLASS 150 MALLEABLE IRON THREADED OR FORGED STEEL SLIP-ON PART 3 EXECUTION DRIVE, ADJUSTABLE VARIABLE PITCH MOTOR PULLEY, AND RUBBER ISOLATED HINGE F. PROVIDE TURNING VANES OF PERFORATED METAL WITH GLASS FIBER INSULATION WHEN 4 PART 2 PRODUCTS FLANGES; PREFORMED NEOPRENE GASKETS. MOUNTED HIGH EFFICIENCY MOTOR OR DIRECT DRIVE AS INDICATED. ISOLATE COMPLETE ACOUSTICAL LINING IS INDICATED. A. PRODUCT DATA: PROVIDE PRODUCT DESCRIPTION, THERMAL CHARACTERISTICS, UST OF 3.01 INSTALLATION 2.01 IDENTIFICATION APPLICATIONS MATERIALS AND THICKNESS FOR EACH SERVICE, AND LOCATIONS. 2. COPPER TUBE AND PIPE: CLASS 150 SUP-ON BRONZE FLANGES; PREFORMED FAN ASSEMBLY. G. INCLUSE DUCT SIZES GRADUALLY, NOT EXCEEDING 15 DEGREES DIVERGENCE WHEREVER y A AIR HANDLING UNITS: NAMEPLATES. B. MANUFACTURER'S INSTRUCTIONS: INDICATE INSTALLATION PROCEDURES NECESSARY TO NEOPRENE CASKETS. A. INSTALL IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. E AIR FILTERS: 2 INCH THICK GLASS FIBER DISPOSABLE MEDIA IN METAL FRAMES AND 2' POSSIBLE; MAXIMUM 30 DEGREES DIVERGENCE UPSTREAM OF EQUIPMENT AND 45 B. DAMPERS: CEILING TACKS, WHERE LOCATED ABOVE LAY-IN CEILING. ENSURE ACCEPTABLE WORKMANSHIP AND THAT INSTALLATION STANDARDS WILL BE 2.06 BALL VALVES B. EXTEND CLEANOUTS TO FINISHED FLOOR OR WALL SURFACE. LUBRICATE THREADED THICK ALUMINUM MESH CLEANABLE FILTERS IN OUTSIDE AIR INTAKE HOOD. DEGREES CONVERGENCE DOWNSTREAM. 0 ACHIEVED. A UP TO AND INCLUDING 2 INCHES CLEANOUT PLUGS WITH MIXTURE OF GRAPHITE AND LINSEED OL ENSURE CLEARANCE AT H. FABRICATE CONTINUOUSLY WELDED ROUND AND OVAL DUCT FITTINGS IN ACCORDANCE WITH C. PIPING: PIPE MARKERS. F. ROOF MOUNTING CURB: 14 INCHES HIGH INSULATED GALVANIZED STEEL CHARNEL FRAME 1.03 QUALfiY ASSURANCE CLEANOUT FOR RODDING OF DRAINAGE SYSTEM. SMACNA HVAC DUCT CONSTRUCTION STANDARDS - META AND FLEXIBLE. D. SMALL-SIZED EQUIPMENT: TAGS. 1. BRONZE, TWO PIECE BODY, CHROME PLATED, BRASS BALL TEFLON SLITS AND TOPPING WITH GASKETS, NAILER STRIPS. 0. MANUFACTURER QUALIFICATIONS: COMPANY SPECIALIZING IN MANUFACTURING PRODUCTS DUX RING, LEVER HANDLES AND BALANCING STOPS, SOLDER OR THREADED ENDS WITH C. ENCASE EXTERIOR CLEMORTS IN CONCRETE FLUSH WITH GRADE. 2.04 ELECTRIC HEATING COL 1. WHERE DUCTS ARE CONNECTED TO EXTERIOR WALL LOUVERS AND DUCT OUTLET IS E. TANKS: NAMEPLATES. UNION. D. INSTALL FLOOR CLEANOUTS AT ELEVATION TO ACCOMMODATE FINISHED FLOOR. SMALLER THAN LOUVER FRAME, PROVIDE TRANSITION TO LOUVER'S FULL PERIMETER. SEAL F. THERMOSTATS: NAMEPLATES. OF THE TYPE SPECIFIED IN THIS SECTION WITH NOT LESS THAN THREE YEARS OF PART 3 EXECUTION A. FINNED TUBE HEATING ELEMENTS EASILY ACCESSIBLE WITH AUTOMATIC RESET THERMAL TO LOUVER FRAME AND DUCT. DOCUMENTED EXPERIENCE. E. INSTALL APPROVED PORTABLE WATER PROTECTION DEVICES ON PLUMBING LINES WHERE CUT-OUT, BUILT-IN MAGNETIC CONTACTORS, GALVANIZED STEEL FRAME, CONTROL CIRCUIT 404 MANUFACTURED DUCTWORK AND FITTINGS z G. VALVES: TAGS AND CEILING TACKS WHERE LOCATED ABOVE LAY-IN CEILING. 1.04 DELIVERY, STORAGE, AND HANDLING 3.01 EXAMINATION CONTAMINATION OF DOMESTIC WATER MAY OCCUR; ON BOILER FEED WATER UNES, JANITOR TRANSFORMER AND FUSE, MANUAL RESET THERMAL CUT-OUT, »AIRFLOW PROVING y H. WATER TREATMENT DEVICES: NAMEPLATES. A. ACCEPT MATERIALS ON SITE IN ORIGINAL FACTORY PACKAGING. LABELED WITH A. VERIFY THAT EXCAVATIONS ME TO REQUIRED GRADE, DRY, AND NOT OVER-EXCAVATED. ROOMS, FIRE SPRINKLER SYSTEMS, PREMISE ISOLATION, IRRIGATION SYSTEMS, RUSH DEVICE,» TOGGLE SWITCH (PILOT DUTY), LOAD FUSES. A DOUBLE WALL INSULATED ROUND DUCTS: ROUND SPIRAL LOCKSEAN DUCT WITH VALVES, INTERIOR AND EXTERIOR HOSE BIBBS. GALVANIZED STEEL OUTER WALL, PERFORATED GALVANIZED STEEL INNER WALL; FIRING 2.02 NAMEPLATES MANUFACTURER'S IDENTIFICATION, INCLUDING PRODUCT DENSITY AND THICKNESS. 3.02 PREPARATION B. CONTROLS: START SUPPLY FAN BEFORE ELECTRIC ELEMENTS ARE ENERGIZED AND WITH SOLID INNER WALL ° A REAM PIPE AND TUBE ENDS. REMOVE BURRS. BEVEL PLAIN END FERROUS PIPE. F. PIPE RELIEF FROM BACKFLOW PREVENTER TO NEAREST DRAIN. CONTINUE OPERATING UNTIL AIR TEMPERATURE REACHES MINIMUM SETTING, WITH SWITCH Y A DESCRIPTION: LAMINATED THREE-LAYER PLSTIC WITH ENGRAVED NETTERS. B. PROTECT INSULATION FROM WEATHER AND CONSTRUCTION TRAFFIC, DIRT, WATER, CHEMICAL, G. INSTAL WATER HAMMER ARRESTORS COMPLETE WITH ACCESSIBLE ISOLATION VALVE ON FOR CONTINUOUS TAN OPERATION. 1. MANUFACTURE IN ACCORDANCE WITH SMACNA HVAC DUCT CONSTRUCTION STANDARDS - 1. LETTER COLOR: WHITE. AND MECHANICAL DAMAGE, BY STORING IN ORIGINAL WRAPPING. B. REMOVE SCALE AND DIRT, ON INSIDE AND OUTSIDE, BEFORE ASSEMBLY. METAL AND FLEXIBLE. HOT AND COLD WATER SUPPLY PIPING TO ALL FIXTURES WITH QUICK CLOSING FIRINGS. 2.05 EVAPORATOR COIL 0 2. LETTER HEIGHT: 1/4 INCH. 1.05 FIELD CONDITIONS C. PREPARE PIPING CONNECTIONS TO EQUIPMENT WITH FLANGES OR UNIONS. 2. INSULATION: 3. BACKGROUND COLOR: BLACK. A MAINTAIN AMBIENT TEMPERATURES AND CONDITIONS REQUIRED BY MANUFACTURERS OF 0. PROVIDE COPPER TUBE ALUMINUM FIN COIL ASSEMBLY WITH GALVANIZED DRAIN PAN AND a. THICKNESS: 1 INCH. 2.03 TAGS ADHESIVES, MASTICS, AND INSULATION CEMENTS. CONNECTION. PROVIDE BOAT SWITCH TO SHUT DOWN UNIT WHERE REQUIRED BY LOCAL B. FLEXIBLE DUCTS: BLACK POLYMER FILM SUPPORTED BY HELICALLY WOUND SPRING CODE. oe APLASTIC TAGS: LANINAIED THREE-DYER PLASTIC WITH ENGRAVED BLACK LETTERS ON 8. MAINTAIN TEMPERATURE DURING AND AFTER INSTAIlATK)N FOR MINIMUM PERIOD OF 24 B. PROVIDE CAPILLARY TUBES OR THERMOSTATIC EXPANSION VALVES FOR UNITS OF 6 TONS STEEL WIRE. M P O .^i LIGHT CONTRASTING BACKGROUND COLOR. TAG SIZE MINIMUM 1-1/2 INCH DIAMETER. HOURS. 1. UL LABELED. CAPACITY AND LESS, AND THERMOSTATIC EXPANSION VALVES AND ALTERNATE ROW .Z$ PART 2 PRODUCTS 2. INSULATION: FIBERGLASS INSULATION WITH POLYETHYLENE VAPOR HARRIER FlLN. B. METAL TAGS: BRASS WITH STAMPED LETTERS; TAG SIZE MINIMUM 1-1/2 INCH DIAMETER CIRCUITING FOR UNITS 7.5 TONS COOLING CAPACITY ANO LAGER. • °"k 3. PRESSURE RATING: 10 INCHES WG POSITIVE AND 0.5 INCHES WG NEGATIVE. z'W WITH SMOOTH EDGES. 2.07 REQUIREMENTS FOR ALL PRODUCTS Of THIS SECTION 4. MAXIMUM VELOCITY: 4000 EPN. �I A. SURFACE BURNING CHARACTERISTICS: FLAME SPREAD/SMOKE DEVELOPED INDEX OF ..a5. TEMPERATURE RANGE: -20 DEGREES F TO 175 DEGREES F. e• 25/50, MAXIMUM, WHEN TESTED IN ACCORDANCE WITH ASTM E 84, NFPA 255, OR UL m t o. 723. WCHAWAL PLUIiiIIIIIIIIIIIII31 xxlb Nwe 2.05 CASINGS 2.04 CEILING EXHAUST AND RETURN REGISTERS/GRILLES 2. INCLUDE AT LEAST THE FOLLOWING IN THE PLM: A FABRICATE CASINGS IN ACCORDANCE WITH SMACNA HVAC DUCT CONSTRUCTION STANDARDS A TYPE: STREAMLINED BLADES, 3/4 INCH MINIMUM DEPTH, 3/4 INCH MAXIMUM SPACING, e. UST OF ALL AIR FLOW, WATER FLOW, SOUND LEVEL, SYSTEM CAPACITY AND - METAL AND FLEXIBLE, AND CONSTRUCT FOR OPERATING PRESSURES INDICATED. WITH BLADES SET AT 45 DEGREES, VERTICAL FACE. EFFICIENCY MEASUREMENTS TO BE PERFORMED AND A DESCRIPTION OF SPECIFIC 0 0 TEST PROCEDURES, PARAMETERS, FORMULAS TO BE USED. B. MOUNT FLOOR MOUNTED CASINGS ON 4 INCH HIGH CONCRETE CURBS. AT FLOOR, RIVET B. FRAME: 1-1/4 INCH MARGIN WITH COUNTERSUNK SCREW MOUNTING. m PANELS ON 8 INCH CENTERS TO ANGLES. WHERE FLOORS ARE ACOUSTICALLY INSULATED, b. COPY OF FIELD CHECKOUT SHEETS AND LOGS TO BE USED, LISTING EACH PIECE OF W _ C. FABRICATION: STEEL WITH 20 CAGE MINIMUM FRAMES AND 22 GAGE MINIMUM BLADES, EQUIPMENT TO BE TESTED, ADJUSTED AND BALANCED WITH THE DATA CELLS TO BE PROVIDE LINER OF 1B GAGE EXPANDED METAL MESH SUPPORTED AT 12 INCH m STEEL AND ALUMINUM WITH 20 GAGE MINIMUM FRAME, OR ALUMINUM EXTRUSIONS, WITH GATHERED FOR EACH.CENTERS, TURNED UP 12 INCHHESES AAT T SIDES WITH SHEET METAL SHIELDS. o o " FACTORY BAKED ENAMEL FINISH. c. DISCUSSION OF WHAT NOTATIONS AND MARKINGS WILL BE MADE ON THE DUCT AND - m e r C. REINFORCE DOOR FRAMES WITH ISTEELNSTALL ANGLES TIED TO HORIZONTAL AND VERTICAL m 0 PLENUM SUPPORTING ANGLES. INSTALL HINGED ACCESS DOORS WHERE INDICATED OR D. COLOR: TO BE SELECTED BY ARCHITECT FROM MANUFACTURER'S STANDARD RANGE. PIPING DRAWINGS DURING THE PROCESS. m REQUIRED FOR ACCESS TO EQUIPMENT FOR CLEANING AND INSPECTION. E. DAMPER: INTEGRAL, GANG-OPERATED, OPPOSED BLADE TYPE WITH REMOVABLE KEY d. FINAL TEST REPORT FORMS TO BE USED. U ''O 0 OPERATOR, OPERABLE FROM FACE WHERE NOT INDIVIDUALLY CONNECTED TO EXHAUST e. PROCEDURES FOR FORMAL DEFICIENCY REPORTS, INCLUDING SCOPE, FREQUENCY E d` 0" PART 3 D(ECUTION FANS. AND DISTRIBUTION. w m n 3.01 INSTALLATIONQ Z3 m N PART 3 EXECUTION C. FINAL REPORT: INDICATE DEFICIENCIES IN SYSTEMS THAT WOULD PREVENT PROPER TESTING, A INSTALL, SUPPORT, AND SEAL DUCTS IN ACCORDANCE WITH SMACNA HVAC DUCTADJUSTING, AND BALANCING OF SYSTEMS AND EQUIPMENT TO ACHIEVE SPECIFIED CONSTRUCTION STANDARDS - METAL AND FLEXIBLE. 3.01 INSTALLATION PERFORMANCE A INSTALL IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. B. INSTALL IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. 1. REVISE TAB PLM! TO REFLECT ACTUAL PROCEDURES AND SUBMIT AS PART OF FINAL W C. WRING CONSTRUCTION PROVIDE TEMPORARY CLOSURES OF METAL OR TAPED B. CHECK LOCATION OF OUTLETS AND INLETS AND MAKE NECESSARY ADJUSTMENTS IN REPORT. W Y POSITION TO CONFORM WITH ARCHITECTURAL FEATURES, SYMMETRY, AND LIGHTING 2. SUBMIT DRAFT COPIES OF REPORT FOR REVIEW PRIOR TO FINAL ACCEPTANCE OF 2 DUCTWORK SYSTEM. POLYETHYLENE ON OPEN DUCTWORK TO PREVENT CONSTRUCTION DUST FROM ENTERING ARRANGEMENT PROJECT. PROVIDE FINAL COPIES FOR ARCHITECT AND FOR INCLUSION IN OPERATING IL �. C. INSTALL DIFFUSERS TO DUCTWORK WITH MR TIGHT CONNECTION. AND MAINTENANCE MANUALS. D. FLEXIBLE DUCTS: CONNECT TO METAL DUCTS WITH ADHESIVE AND MANUFACTURER'S 3INCLUDE ACTUAL INSTRUMENT LIST, WITH MANUFACTURER NAME, SERIAL NUMBER, AND C W . PLASTIC DRAW BANDS. 0. PROVIDE BALANCING DRAPERS ON DUCT TACE-OFF TO DIFFUSERS, AND GRILLES AND F REGISTERS, DESPITE WHETHER DAMPERS ARE SPECIFIED AS PMT OF THE DIFFUSER, OR DATE OF CALIBRATION. N c E. DUCT SIZES INDICATED ARE INSIDE CLEAR DIMENSIONS. FOR LINED DUCTS, MAINTAIN GRILLE AND REGISTER ASSEMBLY. 4. FORM OF TEST REPORTS: WHERE THE TAB STANDARD BEING FOLLOWED RECOMMENDS C SIZES INSIDE LINING. E. PANT DUCTWORK MS113LE BEHIND MR OUTLETS AND INLETS MATTE BLACK. A REPORT FORMAT USE THAT; OTHERWISE, FOLLOW ASHRAE STD 111. lz F. LOCATE DUCTS WITH SUFFICIENT SPACE AROUND EQUIPMENT TO ALLOW NORMAL 5. UNITS OF MEASURE: REPORT DATA IN I-P (INCH-POUND) UNITS. _ OPERATING AND MAINTENANCE ACTIVITIES. SECTION 15940 PMT 2 PRODUCTS - NOT USED V LL G. USE CRIMP JOINTS WITH OR WITHOUT BEAD FOR JOINING ROUND DUCT SIZES 8 INCH PMT 3 EXECUTION AND SMALLER WITH CRIMP IN DIRECTION OF AIR FLOW. HVAC SEQUENCE OF OPERATION 3.01 GENERA REQUIREMENTS H. USE DOUBLE NUTS AND LOCK WASHERS ON THREADED ROD SUPPORTS. I. CONNECT TERMINAL UNITS TO SUPPLY DUCTS DIRECTLY OR WITH FIVE FOOT MAXIMUM A PERFORM TOT- SYSTEM BALANCE ACCORDANCE WITH ONE OF THE FOLLOWING: PART 1 GENERAL 1. AABC MN-1, AABC NATIONALS STANDARDS FOR TOT- SYSTEM BALANCE. LENGTH OF FLEXIBLE DUCT. DO NOT USE FLEXIBLE DUCT TO CHANGE DIRECTION. 1.01 SECTION INCLUDES 2. NEB3 PROCEDURAL STANDARDS FOR TESTING ADJUSTING BALANCING OF ENVIRONMENTAL J. CONNECT DIFFUSERS OR UGHT TROFFER BOOTS TO LOW PRESSURE DUCTS DIRECTLY OR A THIS SECTION DEFINES THE MANNER AND METHOD BY WHICH CONTROLS FUNCTION. SYSTEMS. WITH 5 FEET MAXIMUM LENGTH OF FLEXIBLE DUCT HELD IN PLACE WITH MANUFACTURER'S REQUIREMENTS FOR EACH TYPE OF CONTROL SYSTEM OPERATION ME SPECIFIED. B. BEGIN WORK AFTER COMPLETION OF SYSTEMS TO BE TESTED, ADJUSTED, OR BALANCED AND PLASTIC DRAW BAND. EQUIPMENT, DEVICES, AND SYSTEM COMPONENTS REQUIRED FOR CONTROL SYSTEMS ARE COMPLETE WORK PRIOR TO SUBSTANTIAL COMPLETION OF THE PROJECT. K. AT EXTERIOR WALL LOUVERS, SEAL DUCT TO LOUVER FRAME. SPECIFIED IN OTHER SECTIONS. C. WHERE HVAC SYSTEMS AND/OR COMPONENTS INTERFACE WITH UFE SAFETY SYSTEMS, 302 CLEANING 1.02 SUBMITTALS INCLUDING FIRE AND SMOKE DETECTION, ALARM, AND CONTROL, COORDINATE SCHEDULING, A. CLEAN DUCT SYSTEM AND FORCE AIR AT HIGH VELOCITY THROUGH DUCT TO REMOVE A SEQUENCE OF OPERATION DOCUMENTATION: SUBMIT WRITTEN SEQUENCE OF OPERATION TESTING AND INSPECTION PROCEDURES WITH THE AUTHORITIES HAVING JURISDICTION. ACCUMULATED DUST. TO OBTAIN SUFFICIENT AIR, CLEAN HALF THE SYSTEM AT A TIME. FOR ENTIRE HVAC SYSTEM AND EACH PIECE OF EQUIPMENT. D. TAB AGENCY QUALIFICATIONS: PROTECT EQUIPMENT THAT COULD BE HARMED BY EXCESSIVE DIRT WITH TEMPORARY 1. PREFACE: 1 OR 2 PARAGRAPH OVERVIEW NARRATIVE OF THE SYSTEM DESCRIBING ITS 1. COMPANY SPECIALIZING IN THE TESTING, ADJUSTING, AND BALANCING OF SYSTEMS FILTERS, OR BYPASS DURING CLEANING. PURPOSE, COMPONENTS AND FUNCTION. SPECIFIED IN THIS SECTION. °wa""e ofectroonon Aocememt u B. CLEAN EXISTING DUCTWORK WHERE REUSED, USING THE LATEST NADG STANDARDS FOR 2. STATE EACH SEQUENCE IN SMALL SEGMENTS AND GIVE EACH SEGMENT A UNIQUE dAttunAnn m urmo.ue m•An m EXISTING DUCTWORK. NUMBER FOR REFERENCING IN FUNCTIONAL TEST PROCEDURES; PROVIDE A COMPLETE E. TAB SUPERVISOR AND TECHNICIAN QUALIFICATIONS: CERTIFIED BY SAME ORGANIZATION AS ctir �w the hewo�rOf DESCRIPTION REGARDLESS OF THE COMPLETENESS AND CLARITY OF THE SEQUENCES TAN AGENCY. et the,MAI.f AM thesesol construction The. SECTION 15820 SPECIFIED IN THE CONTRACT DOCUMENTS. 3.02 AIR SYSTEM PROCEDUREtherhores ayKt` 3. INCLUDE AT LEAST THE FOLLOWING SEQUENCES: A PRIOR TO COMMENCING WITH THE BALANCING WORK THE BWANCING CONTRACTOR SHALT INSPECT THE pgYi0 slow select DUCT ACCESSORIES O. START-UP. DUCTWORK INSTALLATION i0 DETERMINE If ALL REQUIRED BALANCING DAMPERS AND ACCESS DOOR of CI,tMbyMt E M ko.Architect. b. WARM-UP MODE. PANELS HAVE BEEN INSTALLED. DO NOT USE OUTLET 080 FOR BALANCING. PMT 1 GENERAL c. NORM- OPERATING MODE. B. PRIOR TO SCHEDULING THE EOC, THE HVAC SUBCONTRACTOR SHALL VERIFY THAT; THE SHIPPING 1.01 SECTION INCLUDES BLOCKS HAVE BEEN REMOVED,, ALL OF THE AIR CONDITIONING WI UNITS ARE OPERATIONAL, DUCTWORK, GAS d. UNOCCUPIED MODE. pPI1G, CONDENSATE PIPING, POWER WIRING AND CONTROL WIRING HAVE BEEN INSTATED. A AIR TURNING DEVICES/EXTRACTORS. e. SHUTDOWN. C. THE HVAC SUBCONTRACTOR SHALL PROVIDE AT THEIR COST A QUAU IED SERVICE TECHNICIAN! TO BE B. DUCT ACCESS DOORS. I. CAPACITY CONTROL SEQUENCES AND EQUIPMENT STAGING. PRESENT DURING THE EQUIPMENT OPERATION CHECK. C. FLEXIBLE DUCT CONNECTIONS. 9. TEMPERATURE AND PRESSURE CONTROL, SUCH AS SETBACKS, SETUPS, RESETS, ETC. D. ANY AND ALL DEFECTS IN THE AIR CONDITIONING UMTS, INSTALLATION AND SYSTEM OPERATION SHALL D. VOLUME CONTROL DAMPERS. h. DETAILED SEQUENCES FOR ALL CONTROL STRATEGIES, SUCH AS ECONOMIZER BE CORRECTED BY THE HVAC SUBCONTRACTOR WITHIN 30 DAYS AFTER THE DISTRIBUTION OF THE EOC 1.02 DELIVERY, STORAGE, AND HANDLING CONTROL, OPTIMUM START/STOP, STAGING, OPTIMIZATION, DEMAND LIMITING, ETC. REPORT. FAILURE TO IDENTIFY A DEFECT DURING THE ECIC DOES NOT RELIEVE THE HVAC i. EFFECTS OF POWER OR EQUIPMENT FAILURE WITH ALL STANDBY COMPONENT SUB-CONTRACTOR OF THE RESPONSIBILITY TO CORRECT SUBSEQUENTLY IDENTIFIED DEFECTS. A PROTECT DAMPERS FROM DAMAGE TO OPERATING LINKAGES AND BLADES. FUNCTIONS E. ALL EQUIPMENT, INSTALLATION, DESIGN AND OPERATION DEFECTS DISCOVERED DURING THE NSTAUATION, PMT 2 PRODUCTS j. SEQUENCES FOR AL ALARMS AND EMERGENCY SHUT DOWNS. CHECK, BALANCE AND OPERATION OF THE HVAC SYSTEM THAT REQUIRE A CHANGE IN THE DESIGN MIO SPECIFICATION OF THE HVAC SYSTEM OR ITS COMPONENTS MUST BE PROPERLY INCORPORATED BY 2.01 AIR TURNING DEVICES/EXTRACTORS k. SEASONAL OPERATIONAL DIFFERENCES AND RECOMMENDATIONS. CHANGE ORDER IN THE PROJECT CONSTRUCTION DOCUMENTS. A MULTI-BLADE DEVICE WITH BLADES ALIGNED IN SHORT DIMENSION; STEEL CONSTRUCTION; I. INTERACTIONS AND INTERLOCKS WITH OTHER SYSTEMS. F. BALANCE ALL FANS AIRFLOW WITHIN +10%/-52 OF DESIGN. REPLACE FAN DRIVE IF REQUIRED TO WITH INDIVIDUALLY ADJUSTABLE BLADES, MOUNTING STRAPS. 4. INCLUDE INITIAL AND RECOMMENDED VALUES FOR ALL ADJUSTABLE SETTINGS, SETPOINTS OBTAIN THE DESIGN CAPACITY. 2.02 DUCT ACCESS DOORS AND PARAMETERS THAT ARE TYPICALLY SET OR ADJUSTED BY OPERATING STAFF; AND G. BALANCE OUTLETS AS FOLLOWS: A FABRICATE IN ACCORDANCE WITH SMACNA HVAC DUCT CONSTRUCTION STANDARDS - ANY OTHER CONTROL SETTINGS OR FIXED VALUES, DELAYS, ETC. THAT WILL BE USEFUL SMALL AREAS WITH 1 OR 2 OUTLETS: +/-5% OF DFSIGN DURING TESTING AND OPERATING THE EQUIPMENT. LARGE MEAS WITH 3 OR MORE OUTLETS: + DESIGN MET- AND FLEXIBLE, AND AS INDICATED. /- 10% OF DES B. ACCESS DOORS WITH SHEET METAL SCREW FASTENERS ME NOT ACCEPTABLE. 5. FOR PACKAGED CONTROLLED EQUIPMENT, INCLUDE MANUFACTURER'S FURNISHED H. REPORT IN WRITING ALL DEFICIENCIES AND PROBLEMS DISCOVERED, AS WELL AS COMPLETED BALANCING SEQUENCE OF OPERATION AMPLIFIED AS REQUIRED TO DESCRIBE THE RELATIONSHIP REPORT TO: THE HVAC SUBCONTRACTOR PRIOR TO COMPLETING THE BALANCING WORK. THIS REPORT 2.03 FLEXIBLE DUCT CONNECTIONS BETWEEN THE PACKAGED CONTROLS AND THE CONTROL SYSTEM, INDICATING WHICH SHOULD INCLUDE THE 'CAUSE' AND SUGGESTED 'SOLUTION', F KNOWN. A FABRICATE IN ACCORDANCE WITH SMACNA HVAC DUCT CONSTRUCTION STANDARDS - POINTS ME ADJUSTABLE CONTROL POINTS AND WHICH POINTS ARE ONLY MONITORED. I THE NR CONDITONING UNITS SWAT BE BALANCED N THE MNIMUM OUTSIDE AIR MODE. THE OUTSIDE METAL AND FLEXIBLE, AND AS INDICATED. B. CONTROL SYSTEM DIAGRAMS: SUBMIT GRAPHIC SCHEMATIC OF THE CONTROL SYSTEM AIR DAMPER `% MINIMUM OPEN POSITION' AND THE 'METHOD' USED SHALL BE INCLUDED IN THE B. FLEXIBLE DUCT CONNECTIONS: FABRIC CRIMPED INTO METAL EDGING STRIP. SHOWING EACH CONTROL COMPONENT AND EACH COMPONENT CONTROLLED, MONITORED, BAINMCING REPORT. ALSO MEASURE AND REPORT THE FAN OPERATING DATA FOR WRITS WITH 1. FABRIC: UL LISTED FIRE-RETARDANT NEOPRENE COATED WOVEN GLASS FIBER FABRIC OR ENABLED' ECONOMIZERS IN THE 100% OUTSIDE AIR MODE. TO NFPA 90A, MINIMUM DENSITY 30 OZ PER SQ YD. 1. LABEL WITH SETTINGS, ADJUSTABLE RANGE OF CONTROL AND LIMITS. J. CORRECTION OF DEFECTS: REQUIRED WITHIN 30 DAYS Of THE DISTRIBUTION OF THE BALANCING REPORT, a. NET FABRIC WIDTH: APPROXIMATELY 2 INCHES WIDE. 2. INCLUDE FLOW DIAGRAMS FOR EACH CONTROL SYSTEM, GRAPHICALLY DEPICTING 2. METAL 3 INCHES WIDE, 24 GAGE THICK GALVANIZED STEEL. CONTROL LOGIC. 3. INCLUDE THE SYSTEM AND COMPONENT LAYOUT OF ALL EQUIPMENT THAT THE CONTROL C. LEADED VINYL SHEET: MINIMUM 0.55 INCH THICK, 0.87 LBS PER SQ FT, 10 DB SYSTEM MONITORS, ENABLES OR CONTROLS, EVEN IF THE EQUIPMENT IS PRIMARILY ATTENUATION IN 10 TO 10,000 HZ RANGE. CONTROLLED BY PACKAGED OR INTEGRAL CONTROLS. D. MAXIMUM INSTALLED LENGTH: 14 INCH. 4. INCLUDE ALL MONITORING. CONTROL AND VIRTUAL POINTS SPECIFIED IN ELSEWHERE. 2.04 VOLUME CONTROL DAMPERS 5. INCLUDE A KEY TO ALL ABBREVIATIONS. A FABRICATE IN ACCORDANCE WITH SMACNA HVAC DUCT CONSTRUCTION STANDARDS - C. POINTS LIST: SUBMIT LIST OF ALL CONTROL POINTS INDICATING AT LEAST THE METAL AND FLEXIBLE, AND AS INDICATED. FOLLOWING FOR EACH POINT. B. SINGLE BLADE DAMPERS: FABRICATE FOR DUCT SIZES UP TO 6 X 30 INCH. 1. NAME OF CONTROLLED SYSTEM. 1. FABRICATE FOR DUCT SIZES UP TO 6 X 30 INCH. 2. POINT ABBREVIATION. 2. BLADE: 24 GAGE, MINIMUM. 3. POINT DESCRIPTION; SUCH AS DRY BULB TEMPERATURE, AIRFLOW, ETC. C. MULTI-BLADE DAMPER: FABRICATE OF OPPOSED BLADE PATTERN WITH MAXIMUM BLADE 4. DISPLAY UNIT. SIZES 8 X 72 INCH. ASSEMBLE CENTER AND EDGE CRIMPED BLADES IN PRIME COATED 5. CONTROL POINT OR SETPOINT (YES / NO); I.E. A POINT THAT CONTROLS EQUIPMENT OR GALVANIZED CHANNEL FRAME WITH SUITABLE HARDWARE. AND CAN HAVE ITS SETPOINT CHANGED. 1. BLADE: 18 GAGE, MINIMUM. 6. MONITORING POINT (YES / NO); I.E. A POINT THAT DOES NOT CONTROL OR D. END BEARINGS: EXCEPT IN ROUND DUCTS 12 INCHES AND SMALLER, PROVIDE END CONTRIBUTE TO THE CONTROL OF EQUIPMENT BUT IS USED FOR OPERATION, BEARINGS. ON MULTIPLE BLADE DAMPERS, PROVIDE OIL-IMPREGNATED NYLON OR MAINTENANCE, OR PERFORMANCE VERIFICATION. SINTERED BRONZE BEARINGS. 7. INTERMEDIATE POINT (YES / NO); I.E. A POINT WHOSE VALUE IS USED TO MAKE A E. QUADRANTS: CALCULATION WHICH THEN CONTROLS EQUIPMENT, SUCH AS SPACE TEMPERATURES THAT 1. PROVIDE LOCKING, INDICATING QUADRANT REGULATORS ON SINGLE AND MULTI-BLADE ARE AVERAGED TO A VIRTUAL POINT TO CONTROL RESET. DAMPERS. B. CALCULATED POINT (YES / NO); I.E. A 'VIRTUAL' POINT GENERATED FROM 2. ON INSULATED DUCTS MOUNT QUADRANT REGULATORS ON STAND-OFF MOUNTING CALCULATIONS OF OTHER POINT VALUES. BRACKETS, BASES, OR ADAPTERS. D. PROJECT RECORD DOCUMENTS: RECORD ACTUAL LOCATIONS OF COMPONENTS AND 3. WHERE ROD LENGTHS EXCEED 30 INCHES PROVIDE REGULATOR AT BOTH ENDS. SETPOINTS OF CONTROLS, INCLUDING CHANGES TO SEQUENCES MADE AFTER SUBMISSION PMT 3 EXECUTION OF SHOP DRAWINGS. PART 2 PRODUCTS - NOT USED 3.01 INSTALLATION PMT 3 EXECUTION A INSTALL ACCESSORIES IN ACCORDANCE WITH MMUFACTURER'S INSTRUCTIONS, AND FOLLOW 3.01 ROOFTOP AIR CONDITIONING UNIT SYSTEMS SMACNA HVAC DUCT CONSTRUCTION STANDARDS - METAL AND FLEXIBLE B. PROVIDE DUCT ACCESS DOORS FOR INSPECTION AND CLEANING BEFORE AND AFTER A WALL MOUNTED THERMOSTAT FURNISHED AS ACCESSORY TO UNIT SHALL SEQUENCE FILTERS, COILS, FANS, AUTOMATIC DAMPERS, AND ELSEWHERE AS INDICATED. PROVIDE HEATING AND COOLING. PROVIDE WITH SUB-BASE TO MANUALLY SELECT HEATING, ' MINIMUM B X 8 INCH SIZE FOR RAND ACCESS, SIZE FOR SHOULDER ACCESS, AND AS COOLING, FAN ON-OFF, AUTO OPERATION. INDICATED. PROVIDE 4 X 4 INCH FOR BALANCING DAMPERS ONLY. RENEW LOCATIONS B. UNIT SHALL OPERATE IN OCCUPIED OR UNOCCUPIED MODES BASED UPON TIME CLOCK a PRIOR TO FABRICATION. SEQUENCE AS DETERMINED BY OWNER. C. PROVIDE DUCT TEST HOLES WHERE INDICATED AND REQUIRED FOR TESTING AND C. UNOCCUPIED MODE - THE SUPPLY FAN WILL BE OFF, THE OUTDOOR AR DAMPER WILL f«. BALANCING PURPOSES. GO TO 100% CLOSED POSITION AND UNIT WILL CYCLE ON WITH CAL FOR HEATING OR - • D. AT FANS AND MOTORIZED EQUIPMENT ASSOCIATED WITH DUCTS, PROVIDE FLEXIBLE DUCT COOLING. ^* CONNECTIONS IMMEDIATELY ADJACENT TO THE EQUIPMENT. D. OCCUPIED MODE - THE SUPPLY FAN SHALL RUN CONTINUOUSLY, THE OUTDOOR AIR ef� E. AT EQUIPMENT SUPPORTED BY VIBRATION ISOLATORS, PROVIDE FLEXIBLE DUCT DAMPER WILL OPEN TO THE MINIMUM AIR POSITION AND THE UNIT WILL GO IMO THE CONNECTIONS IMMEDIATELY ADJACENT TO THE EQUIPMENT; HEATING OR COOLING MODE, BASED UPON ROOM THERMOSTAT SETPOINT TEMPERATURE. F. FOR FMS DEVELOPING STATIC PRESSURES 5.0 INCHES AND OVER, COVER FLEXIBLE E. UPON CALL FOR COOLING, THE OUTDOOR AIR TEMPERATURE IS 55 DEGREES F. CONNECTIONS WITH LEADED VINYL SHEET, HELD IN PUCE WITH MET- STRAPS. (ADJUSTABLE), THE OUTSIDE AIR DAMPER SHALL GO TO MINIMUM POSITION, AND THE COMPRESSORS WILL DU ENERGIZED G. PROVIDE BALANCING DAMPERS AT POINTS ON SUPPLY, RETURN, AND EXHAUST SYSTEMS o F. UPON A CALL FOR HEATING, THE GAS BURNER SHALL FIRE. BALANCING.BRANCHES ARE TAKEN FROM LARGER DUCTS AS REQUIRED FOR AIR BAICING. LU W- INSTALL MINIMUM 2 DUCT WIDTHS FROM DUCT TAKE-OFF. G. A LOW TEMPERATURE THERMOSTAT WILL DE-ENERC42E THE SUPPLY FAN AND CLOSE THE H. PROVIDE BALANCING DAMPERS ON DUCT TAKE-OFF TO DIFFUSERS, GRILLES, AND OUTSIDE AIR DAMPER IF THE MIXED AIR TEMPERATURE IS SENSED AT 40 DEGREES F OR y REGISTERS, REGARDLESS OF WHETHER DAMPERS ME SPECIFIED AS PMT OF THE COLDER. DIFFUSER, GRILLE, OR REGISTER ASSEMBLY. H. A DUCT MOUNTED, PHOTOELECTRIC SMOKE DETECTOR (FURNISHED BY ELECTRICAL 2 CONTRACTOR AND INSTATED BY MECHANICAL CONTRACTOR) SHALL SHUT DOWN THE UNIT, F- W W SECTION 15850 CLOSE THE OUTSIDE ARE DAMPER AND SEND A SIGNAL TO THE FIRE ALARM PANEL WHEN -G 2 Ir AIR DISTRIBUTION DEVICES ACTUATED. BOTH SAFETIES WILL REQUIRE MANUAL RESET, AND WILL ACTIVATE AN ALARM 4 m < j y N PART 1 GENERA AT THE LOC- CONTROL PANEL LAI= 0Y m 1.01 SECTION INCLUDES d << 0 CC A DIFFUSERS. 0 B. REGISTERS/GRILLES. Z N 2 PMT 2 PRODUCTS < 2.01 MANUFACTURERS, AS SCHEDULED ON DRAWINGS OR APPROVED EQUAL. Mz C1 2.02 RECTANGULAR CEILING DIFFUSERS SECTION 15950 H A TYPE: SQUARE, STAMPED, MULTI-CORE DIFFUSER TO DISCHARGE AIR IN 360 DEGREE TESTING, ADJUSTING, AND BALANCING PATTERN WITH SECTORIZING BAFFLES WHERE INDICATED. Raper Eld 1m75 B. FRAME: SURFACE MOUNT TYPE. IN PLASTER CEILINGS, PROVIDE PIASTER FRAME AND PART 1 GENERAL CEILING FRAME. PROVIDE FLANGED FRAME FOR SUSPENDED LAYIN COUNGS 1.01 SECTION INCLUDES JPU C. FABRICATION: STEEL WITH BAKED ENAMEL FINISH. A TESTING, ADJUSTMENT, AND BALANCING OF AIR SYSTEMS. Ora how D. COLOR: AS SELECTED BY ARCHITECT FROM MANUFACTURER'S STANDARD RANGE. B. TESTING, ADJUSTMENT, AND BALANCING OF REFRIGERATING SYSTEMS. 07TOFJOQI int C E. ACCESSORIES: ROUND TO SQUARE ADAPTORS, RADIAL OPPOSED BLADE DAMPER AND C. MEASUREMENT OF FINAL OPERATING CONDITION OF HVAC SYSTEMS. MULTI-LOUVERED EQUALIZING GRID WITH DAMPER ADJUSTABLE FROM DIFFUSER FACE. 1.02 SUBMITTALS 2.03 CEILING SUPPLY REGISTERS/GRILLES A TAB PEM: SUBMIT A WRITTEN PLM INDICATING THE TESTING, ADJUSTING, AND BALANCING A TYPE: STREAMLINED AND INDMDUALLY ADJUSTABLE CURVED BLADES TO DISCHARGE AIR STANDARD TO BE FOLLOWED AND THE SPECIFIC APPROACH FOR EACH SYSTEM AND ALONG FACE OF GRILLE, ONE-WAY DEFLECTION. COMPONENT. a 1. INCLUDE CERTIFICATION THAT THE PLM DEVELOPER HAS REVIEWED THE CONTRACT W B. FRAME: 1-1/4 INCH MARGIN WITH COUNTERSUNK SCREW MOUNTING AND GASKET. DOCUMENTS, THE EQUIPMENT AND SYSTEMS. AND THE CONTROL SYSTEM WITH THE C. FABRICATION: ALUMINUM EXTRUSIONS WITH FACTORY ENAMEL FINISH. ARCHITECT AND OTHER INSTALLERS TO SUFFICIENTLY UNDERSTAND THE DESIGN INTENT x D. COLOR: AS SELECTED BY ARCHITECT FROM MANUFACTURER'S STANDARD RANGE, FOR EACH SYSTEM. E. DAMPER: INTEGRAL, GANG-OPERATED, OPPOSED BLADE TYPE WITH REMOVABLE KEY OPERATOR, OPERABLE FROM FACE. N S b �a MP2 .0 fo;�= FNJO U ry '0 x3 MECHANICAL PLUMBING SPECS