Plans (162) BUP2012 - 00191
DRAWING INDEX DEMOLITION RECHM
E
10 2012an
1. EXISTING STRUCTURE TO BE LEFT UNDISTURBED AND INTACT. PERFORM NO DEMOLITION THAT MAY COMPROMISE THE `I, OF, A
RD
0001 CODE SHEET & GENERAL INFORMATION STRUCTURAL INTEGRITY OF THE BUILDING WITHOUT WRITTEN APPROVAL OF THE ARCHITECT / ENGINEER. TENANT IMPROVEMENT FOR
BUILD[NG DIVISION
A102 DEMOLITION PLAN & FLOOR PLAN 2. EXTREME CARE SHALL BE TAKEN BY THE CONTRACTOR TO PROTECT ALL EXISTING AREAS TO REMAIN FROM DAMAGES THAT ARCHITECTS
A800 DETAILS / FINISH SCHEDULE MIGHT OCCUR DURING DEMOLITION. THE CONTRACTOR WILL BE HELD RESPONSIBLE FOR ALL AREAS THAT HAVE BEEN 2ND FLOOR RESTROOMS
DAMAGED DUE TO INADEQUATE PROTECTION.
3. MAINTAIN 100% FIRE ALARM COVERAGE. 1120 NW Couch Street
4, REMOVE ALL EXISTING SIGNAGE, PICTURES, NAILS, HOOKS, EQUIPMENT, ETC., LEFT BEHIND FROM PRIOR TENANT, FROM ALL Suite 300, Portland
WALLS, DOORS, DOOR FRAMES, STRUCTURAL, AND CONCRETE CEILING. O R 9 7 2 0 9
CODE SUMMARY I Tel: ((503 229.6273
CONTACTS � Fax: (503) 299.6273_-_ __ _ _ __ _ __ CONSTRUCTION
_ ----------� www.gbdarchitects.com
CODE 2010 OREGON STRUCTURAL SPECIALTY CODE ZONING MUE-1
1. PERFORM ALL WORK IN ACCORDANCE WITH ESTABLISHED BUILDING STANDARDS FOR TENANT IMPROVEMENTS. BUILDING MANAGEMENT: CONTRACTOR: ARCHITECT:
FIRE PROTECTION SMOKE DETECTION SYSTEM NORRIS, BEGGS & SIMPSON COMMERCIAL CONTRACTORS, INC GBD ARCHITECTS, Incorporated ��,��'� Akr
BUILDING IS CURRENTLY IN PROCESS OF 2. ALL DIMENSIONS ARE TO FACE OF FINISHED SURFACE UNLESS NOTED OTHERWISE. ALL PARTITIONS TERMINATE AT THE COMMERCIAL REAL ESTATE SERVICES 1265 S. 35th Place 1120 NW Couch Street
ADDING SPRINKLERS UNDERSIDE OF THE EXISTING SUSPENDED CEILING UNLESS OTHERWISE NOTED.
121 SW Morrison IG L. D
Ridgefield, WA 98642 Suite - 300
Suite - 200 Portland, Oregon 97209
AREA N / A CONSTRUCTION TYPE: 2B 3. MECHANICAL, ELECTRICAL AND FIRE PROTECTION SYSTEMS INDICATED ARE FOR INFORMATION ONLY. THESE SYSTEMS ARE Phone: 503/227-4440 1 ,
SUB-CONTRACTOR DESIGN/BUILD AND ARE TO BE SUBMITTED UNDER SEPARATE PERMIT, UNDER THE MASTER PERMIT FOR Portland, Oregon 97204 1
ORTL OREGON
THIS PROJECT. IT IS THE RESPONSIBILITY OF THE DESIGN/BUILD SUB-CONTRACTOR TO OBTAIN THESE PERMITS. Fax: 503/227-6644 Phone: 503/224-9656 t��
STORIES 5 Contact: Eric Mone 08
CONTRACTORS SHALL VERIFY SIZES AND LOCATIONS OF ALL MECHANICAL AND ELECTRICAL EQUIPMENT, BOTH EXISTING AND Phone: 503/352-8113 y Fax: 503/299-6273 �?
NEW. Cell Phone: 503 209-1617
Fax: 503/352-9339 / Contact: Kent Pottebaum OF 00
OCCUPANT LOAD, N / A EGRESS N / A 4. MAINTAIN 100% SPRINKLER COVERAGE (BUILDING IS CURRENTLY IN PROCESS OF ADDING SPRINKLERS). Contact: Beverly Chesnut Foster Email: eric@ccigc.com Cell Phone: 503/358-0531 j
N / A 5. ALL WALLS, DOORS, FLOORS, CEILINGS WITHIN THE LIMITS OF WORK NOTED, ARE TO BE PATCHED, PLASTERED, SANDED AND Email: bchesnutfoster@nal-nbs.com Email: Kent@gbdarchitects.com cao
PREPARED READY FOR THE NEW FINISH SPECIFIED.
THE GENERAL NOTES PACKAGE. THEY DO GENSRAL NOT REAPPEARNOTESPLY ON TOHE ACH INDIVIDUA DRAWING FOLLOWINGIN 6. PROVIDE EXIT SIGNS AND EMERGENCY LIGHTING SYSTEM IN CONFORMANCE WITH CITY OF TIGARD REQUIREMENTS.
A. ALL WORK IN THIS BUILDING IS TO BE PERFORMED UNDER THE CITY OF TIGARD PERMIT PROGRAM. A MASTER PROJECT 7. THE DESIGN OF ALL SEISMIC BRACING AND SUPPORTS FOR CEILING, MECHANICAL AND ELECTRICAL ITEMS AND PARTITIONS IS PLAZA WEST
NUMBER WILL BE ISSUED FOR THE PROJECT. ALL OTHER DESIGN BUILD PERMITS ARE TO BE TAKEN OUT AS SEPARATE THE RESPONSIBILITY OF THE RESPECTIVE CONTRACTOR/VENDOR TO MEET CITY OF TIGARD BUILDING CODE. 2ND FLOOR RESTROOMS
PERMITS UNDER THE MASTER PROJECT NUMBER. I /� /� \w,C
B. MECHANICAL WORK IS PROVIDED THROUGH A CONTRACTOR DESIGN BUILD SYSTEM. MECHANICAL WORK INDICATED IN THESE 8 INTEGRITY OFSEAL ALL .
B. LOOR WALL ASSEMgWALL PENETRATIONS WITH RATED ASSEMBLIES AS REQUIRED TO MAINTAIN THE EGRESS PLAN PLAZA vv CST
DOCUMENTS IS FOR INFORMATION ONLY, MECHANICAL CONTRACTOR IS TO FIELD VERIFY ALL EXISTING CONDITIONS AND g. DOORS OR OPENINGS LOCATED BY A WALL AT A RIGHT ANGLE ARE TO BE INSTALLED 4 INCHES FROM SAID CONDITION. THIS
PROVIDE ENGINEERED DRAWINGS TO MEET THE DESIGN DEPICTED IN THESE DOCUMENTS AND ALL CITY OF TIGARD BUILDING CONDITION IS TYPICAL AND WILL NOT BE DIMENSIONED. 9600 SOUTHWEST OAK ST
CODE REQUIREMENTS, MECHANICAL CONTRACTOR IS TO MEET ALL CITY OF TIGARD SUBMITTAL REQUIREMENTS FOR DESIGN
BUILD PROJECTS, AND SUBMIT PROJECT TO CITY OF TIGARD. MECHANICAL DESIGN BUILD DRAWINGS SHALL BE SUBMITTED, 10, ALL NEW AND EXISTING DOORS TO BE SOLID CORE FLUSH TO MATCH BUILDING STANDARD AND HAVE BUILDING STANDARD TIGARD, OREGON 97223
AND APPROVED BY THE OWNER'S CONSTRUCTION MANAGER AND ARCHITECT, PRIOR TO ISSUING TO THE CITY OF TIGARD FOR LEVER HARDWARE
PERMIT. 11. UTILIZE ZERO VOC PAINT SYSTEMS, INCLUDING PRIMERS AND FINISH PRODUCTS. �� LIMITS
IWORKOF
C. PLUMBING WORK IS PROVIDED THROUGH A CONTRACTOR DESIGN BUILD SYSTEM. PLUMBING WORK INDICATED IN THESE 12. PROVIDE SOUND INSULATION IN ALL NEW WALLS EXCEPT FOR LOW OR PARTIAL HEIGHT PARTITIONS.
DOCUMENTS IS FOR INFORMATION ONLY. PLUMBING CONTRACTOR IS TO FIELD VERIFY ALL EXISTING CONDITIONS AND PROVIDE
ENGINEERED DRAWINGS TO MEET THE DESIGN DEPICTED IN THESE DOCUMENTS AND ALL CITY OF TIGARD BUILDING CODE
REQUIREMENTS. PLUMBING CONTRACTOR IS TO MEET ALL CITY OF TIGARD SUBMITTAL REQUIREMENTS FOR DESIGN BUILD e
PROJECTS, AND SUBMIT PROJECT THROUGH THE CITY OF TIGARD PERMIT PROGRAM. MAINTAIN 100% SPRINKLER COVERAGE MECHANICAL '
THROUGHOUT BUILDING, PLUMBING DESIGN BUILD DRAWINGS SHALL BE SUBMITTED, REVIEWED AND APPROVED BY THE ( — — 4
OWNER'S CONSTRUCTION MANAGER AND ARCHITECT, PRIOR TO ISSUING TO THE CITY OF TIGARD FOR PERMIT.
i
1. MECHANICAL AND FIRE PROTECTION SYSTEM WORK INDICATED IS FOR INFORMATION ONLY. CONTRACTORS SHALL VERIFY I - -- -
D. ELECTRICAL WORK IS PROVIDED THROUGH A CONTRACTOR DESIGN BUILD SYSTEM. ELECTRICAL WORK INDICATED IN THESESIZES AND LOCATIONS OF ALL EQUIPMENT, BOTH EXISTING AND NEW. THESE SYSTEMS ARE SUB-CONTRACTOR DESIGN/BUILD
DOCUMENTS IS FOR INFORMATION ONLY. ELECTRICAL CONTRACTOR IS TO FIELD VERIFY ALL EXISTING CONDITIONS AND AND ARE TO BE SUBMITTED UNDER SEPARATE PERMIT. IT IS THE RESPONSIBILITY OF THE DESIGN/BUILD SUB-CONTRACTOR I -
PROVIDE ENGINEERED DRAWINGS TO MEET THE DESIGN DEPICTED IN THESE DOCUMENTS AND ALL CITY OF TIGARD BUILDING TO OBTAIN THESE PERMITS. DESIGN BUILD DRAWINGS SHALL BE SUBMITTED, REVIEWED AND APPROVED BY THE OWNER'S Fj_
CODE REOUiREMENTS. ELECTRICAL CONTRACTOR IS TO MEET ALL CITY OF TIGARD SUBMITTAL REQUIREMENTS FOR DESIGN CONSTRUCTION MANAGER AND ARCHITECT PRIOR TO SUBMITTING TO THE CITY OF TIGARD FOR PERMIT.
BUILD PROJECTS, AND SUBMIT PROJECT THROUGH THE CITY OF TIGARD PERMIT PROGRAM. ELECTRICAL DESIGN BUILD
� � l
DRAWINGS SHALL BE SUBMITTED, REVIEWED AND APPROVED BY THE OWNER'S CONSTRUCTION MANAGER AND ARCHITECT PRIOR 2. CONTRACTOR TO PROVIDE CFM DELIVERY FOR EACH REGISTER ON THE MECHANICAL DB DRAWINGS.
TO ISSUING .TO THE CITY OF TIGARD FOR PERMIT. 17, Z�_
---
m
I
3. ALL MECHANICAL PLANS ARE TO BE SUBMITTED FOR APPROVAL BY THE OWNERS' CONSTRUCTION MANAGER AND ARCHITECT
E. EXIT AND EGRESS LIGHTING SYSTEM ARE TO BE INSTALLED TO MEET THE IBC AND PRESCRIPTIVE LIGHTING PATH (IBC 2009 PRIOR TO COMMENCEMENT OF MECHANICAL WORK.
AND 2010 OSSC.) EGRESS PLAN IS INDICATED IN THESE DOCUMENTS.
IT AND
F. MAINTAIN EXISTING BUILDING FIRE AND LIFE SAFETY SYSTEMS INCLUDING, BUT NOT LIMITED TO SPRINKLER SYSTEMS, SMOKE 4. CONTRACTOR TO SUBMIT ALONG WITH BID NUMBER OF EXISTING AND PROPOSED VAV BOXES AND TERMINAL UNITS - -"-"
CONTEMPLATED AS PART OF DESIGN BUILD CONTRACT.
DETECTION SYSTEMS, SMOKE EVACUATION SYSTEMS, EXITING SYSTEMS AND EMERGENCY ANNUNCIATION SYSTEMS. ISSUEDCONS FOR RUCTIO ON
CONSTRUCTION ON OCT.i,2012
G. ALL WORK SHALL CONFORM TO APPLICABLE BUILDING CODES AND ORDINANCES, AS MODIFIED FOR THIS BUILDING ON
RECORD AT THE CITY OF TIGARD. IN CASE OF CONFLICT WHERE THE METHODS OR STANDARDS OF INSTALLATION OF THE LEGEND
MATERIALS SPECIFIED DO NOT EQUAL OR EXCEED THE REQUIREMENTS OF THE LAWS OR ORDINANCES, THE LAW OR ELECTRICAL N
ORDINANCE SHALL GOVERN. NOTIFY ARCHITECT OF CONFLICTS. _ EXIT
H. IT IS THE CONTRACTOR'S RESPONSIBILITY TO VERIFY EXISTING CONDITIONS. NO ALLOWANCE WILL.BE MADE FOR 1. ELECTRICAL WORK INDICATED IS FOR INFORMATION ONLY. CONTRACTORS SHALL VERIFY SIZES AND LOCATIONS OF ALL
UNFAVORABLE CONDITIONS OR EVENT WHICH MIGHT HAVE BEEN DISCOVERED THROUGH A THOROUGH EXAMINATION OF THE EQUIPMENT, BOTH EXISTING AND NEW. THESE SYSTEMS ARE SUB-CONTRACTOR DESIGN/BUILD AND ARE TO BE SUBMITTED DENOTES AREA OF MIN 3-8 WIDE EGRESS PATH
SITE. CONTRACTOR SHALL ASSUME FULL RESPONSIBILITY FOR THE CONSEQUENCES OF ACTING ON CONCLUSIONS DRAWN UNDER SEPARATE PERMIT. IT IS THE RESPONSIBILITY OF THE DESIGN/BUILD SUB-CONTRACTOR TO OBTAIN THESE PERMITS.
FROM INFORMATION AVAILABLE AT THE TIME. DESIGN BUILD DRAWINGS SHALL BE SUBMITTED, REVIEWED AND APPROVED BY THE OWNER'S CONSTRUCTION MANAGER AND
I. NOTIFY THE ARCHITECT IN WRITING, OF ANY DISCREPANCIES PRIOR TO PROCEEDING WITH WORK. ARCHITECT PRIOR TO SUBMITTING TO THE CITY OF TIGARD FOR PERMIT. PROVIDE EGRESS ILLUMINATION ALONG EXIT PATH NOT LESS THAN (1FOOT
CANDLE MEASURED CONTINUOULY AT THE WALKING SURFACE.
J. PROVIDE ALL LABOR, TRANSPORTATION, EQUIPMENT AND SERVICES NECESSARY TO PERFORM WORK SHOWN ON THE DRAWINGS 2. ALL NEW ELECTRICAL OUTLETS TO BE MOUNTED AT +18" UNLESS NOTED OTHERWISE.
AND DESCRIBED HEREIN.
3. ALL RECEPTACLES, SWITCHES AND COVERS TO BE BUILDING STANDARD AND MATCH IN COLOR. FIELD VERIFY COLOR UNLESS
OTHERWISE NOTED.
5TH FLOOR PLAN
4. SWITCHING FOR ALL LIGHT FIXTURES TO BE COORDINATED BETWEEN ARCHITECTURAL AND ELECTRICAL DRAWINGS PRIOR TO C/ ` REVISIONS
BEGINNING OF WORK. CONFIRM W/ ARCHITECT.
5. MODIFY EMERGENCY EGRESS LIGHTING AS NECESSARY TO MATCH PRESCRIBED PATH AND TO CONFORM WITH IBC 2009 AND DATE
2010 OSSC. SEE EGRESS PLAN FOR EGRESS LIGHTING PATH. October 02, 2012
CITY OF TIGARD �
Approved......:�,...................
o Conditionally Approved. ............[ ] PROJECT NUMBER
VICINITY PLAN See Letter to:Follow.................._tn [ ]
v NORTH A' ed .....
� r PermitNumb�erC Ad
: � Of -O�/ 20031075
Dy: —Date: '
0-T-C r
Occupancy T Type � SHEET TITLE
E
o Occupancy Low +...�
Construction Type
h CODE SHEET AND
N ;
)..
Rated Corridor
GENERAL INFORMATION
' SVV
o Energy Code
2fi7 'q..b
Accessibility
W C3ak St S yak St S tisk t
-a M �a . SCALE
N
_ Approved plans N.T.
i
3 ITS.
CL
shall be on job site.
o
Q
N ,.a OFFICE COPY
m � '%�..
r C14 "J
G001
a- o
00 , "
Q U
UO
G BDARCHITECTSIncorporated
I
LIMITS OF WORK LIMITS OF WORK r
r--- - - - - - - - - - - - - - - - -� r - - -- - - - - - - - - - - - - - - -� r -- - - �, - - - - - -- - - - - - -- - - - - - - - - --i{ ARCHITECTS
l— i i = I
1 I —� 0 1 1 5 0 1 O 5 PLAN REFERENCE NOTES
1 ii 1 1 I 1 1 0 19 1 19 12 1 1120 NW Couch Street
it 0 II ET!@()�)
,� 16 = Suite 300, Portland
D PID 000 �i REMOVE EXISTING GRAB BAR.
14 3 14 I CDTPD i4 nr�.0 TMP. OTPDTRlfj� 12 15 P 15 OIRTPD i 1 0 R 9 2 0 9
TMP Tel: (503) 224.9656
1 0 , '� i 1 14111, 11L;U ° 1 1 N op ,� I9 12 Fo N � 1 OZ REMOVE EXISTING CASEWORK AND SINKS.
t'^ 1 1 I TMP. II II I T- 1 Fax: (503) 299.6273
N "DIA� . 12 60"D N 1 www.gbdarchitects.com
1 1 �} �' 22 O REMOVE TOILET PAPER DISPENSER (TPD), SANITARY COVER DISPENSER (SC),
" 1 1 0 '� ' 1 1 '9 j TRASH RECEPTACLE (TR), PAPER TOWEL DISPENSER/WASTE RECEPTACLE D
MEN'S to WOMEN'S MEN'S le , WOMEN'S
201 202 O m 201 � . 15 � ��202 n � A
—'-"j
1 1 ____'�_____ID 1 1 OF Or i (PTD/WR), AND SANITARY NAPKIN DISPENSER (SND) SALVAGE FOR RE-USE OR �' �'C
CORRIDOR 1 im ;/�^ 1 1 1 CORRIDOR i 1� ° i RETURN TO BUILDING STOCKPILE.
8 A, 1 i A , - 1 RAIL AVIS, C6
21 0 PT1 XIS . 1 200 1 IST. T1 80 2, N 1
1 PTD 3 1 1 SNDOPTD ; 1 1 �, 2z -_PO----- B jQ; ro
1 1 J 12 8 --PTD__ 2s N 1 PROVIDE AND INSTALL 5/8" GYPSUM BOARD OVER METAL STUD FURRING.
1 1 1 1 1 LJ 1 1 1 PO AND, OREGON
1 i 1 1 1 1 1 1 PROVIDE AND INSTALL NEW GRAB BAR, REFER TO 19/A800. �/'� 3008
OF 1 1 1 1 1 1 1 1 � �'� 0.���
O PROVIDE AND INSTALL NEW BUILDING STANDARD ELECTRONIC ADA DOOR
DEMO FLOOR PLAN N 2 FLOOR PLAN TO PROVIDE INSTALLALLBACKING�INIOWALLEAS TREQUOIREDACTOR IS RESPONSIBLE N OPENER.
1 ) �o
1/4" = 1 '-0" 1/4" = 1 '-0" O REMOVE EXISTING WALL MOUNTED LIGHT FIXTURE, RELOCATE J-BOX AND
ELECTRICAL WIRES TO LOCATION SHOWN ON ELEVATIONS. PROVIDE AND INSTAL
NEW LIGHT FIXTURE, PATCH WALL. ! PLAZA WEST
REMOVE EXISTING MIRROR, RETURN TO BUILDING STOCKPILE. 2ND FLOOR RESTROOMS
LIMITS OF WORK LIMITS OF WORK PROVIDE AND INSTALL NEW LIGHT FIXTURE REFER TO ELEVATIONS FOR PLAZA WEST
LOCATIONS. 9600 SOUTHWEST OAK ST
- - - - - - .., ,,. - - �„� - - - - - - - � �, - - - - - - - - - - - - - - - - - - - .� �. _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ .� t. _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ - _ _ _ � Im REMOVE ALL FLOORING, WALL TILE AND BASE MATERIALS. PATCH WALL AS TIGARD, OREGON 97223
REQUIRED AT SOUTH WALL OF BOTH RESTROOMS.
1 n 1 1 n 1 1 1 1 1
1 n0 ' 1 i 7 On 1 1 0 1 1 1 II PROVIDE AND INSTALL NEW TILE FLOORING, PT-1 . SEE DETAIL 5/A102 FOR '
i -u 1 1 1 1 0 1 1 g 1 LAYOUT.
1 1 1 1 1 I 1 1
1 1 1 1 1 1 1 1
1 1 1 1 1 13 1 i 13 1 12 REUSE TPD, TR, SCD AND SND. REFER TO 19/A800 FOR MOUNTING ;
1 n0 On 1 1 O" 1 1 O 1 ; 1 1 DIMENSIONS.
1 1 n 1 1 1 1 1
1 1 1 u O 1 i 1 i i 13 EXISTING SUSPENDED CEILING GRID AND TILE TO REMAIN. I
1 1 1 1 �
1 1 1 1 1 1 1 1
1 n 1 1 n 1 1 1 1 1 14 CONTRACTOR TO DOCUMENT EXISTING LOCATION OF TOILET PARTITIONS. REMOVE
o� 1 1 1 1 g 1 EXISTING TOILET PARTITIONS ,SALVAGE FOR RE-USE.
1 1 1 1 1 1 1 1 I
1 1 1 1 i 15 CONTRACTOR TO RE-INSTALL EXISTING TOILET PARTITION IN ORIGINAL LOCATION.
i 1 1 1 1 1 1 1 REPLACE DAMAGED PARTITIONS AND PAINT.
1 1 1 1 1 1 1 1 �
16 PROVIDE AND INSTALL NEW TOILET PARTITION PAINT TO MATCH (P-2).
3 DEMO REFLECTED CEILING PLAN
N 4 REFLECTED CEILING PLAN N �� DEMO WALL AS REQUIRED TO INSTALL NEW COUNTER SUPPORTS AND I& C°�Rocr%ONOCL1.2012
I
PLUMBING, SEE DETAIL 4/A800. PATCH WALL AS REQUIRED TO RECEIVE NEW
WALL FINISH.
I
IS PROVIDE AND INSTALL NEW BUILDING STANDARD ADA PLUMBING FIXTURE. I
LIMITS O F WORK FIXTURES TO BE INSTALLED AT CURRENT AMERICANS NATIONAL STANDARDS,
2003 EDITION.
I
� L�� i � �. _ _ __ _ _ � _ _ _ _ _ _ _ _ _ _ _ _ _ .� {g PROVIDE AND INSTALL NEW BUILDING STANDARD PLUMBING FIXTURES.
1 1 1 1 LEGEND
1 1 _.. - 1 0 PROVIDE AND INSTALL CRACK/WATER PROOF MEMBRANE.
_ ._.__ EXISTING WALL
ITEM TO BE REMOVED--------
LOBBY ROOM NAME 21 PROVIDE AND INSTALL NEW PAPER TOWEL DISPENSER/WASTE RECEPTACLE INSET
ROOM NUMBERREVISIONS
1 a S STEEL.
- -Y - - - 1 w 1 NEW WALL IN ORIGINAL LOCATION GEORGIA PACIFIC, GP 59451 , FINISH: STAINLESS
1 w Oi ARCHITECTURAL PLAN REFERENCE NOTE
NEW PARTIAL HEIGHT WALL !
PROVIDE AND INSTALL NEW SINK: KOHLER-LADENA K-22- 15-0, FINISH: WHITE, DATE
NEW FRAMELESS RECITE
REVISION NUMBER NEW ELECTRONIC FAUCET: DELTA-DEMD- 111 , AND NEW ELECTRONIC SOAP October 02, 2012
ELEVATION REFERENCE DISPENSER: DELTA-DESD-250.
_ LLJ
C 1 o A201 SHEET REFERENCE
ft}jt[
NEW DOOR AND FRAME .
1 - PROJECT NUMBER
f _ _._ .. . 1 1 __. �_- ._. :. DETAIL REFERENCE
U 1 ___ t 1 - - ` 1 VOICE AND DATA SHEET REFERENCE
N 1 1
1 _ . 1 20031 075
1 1 __j._. s EXISTING ADA STROBE
3 1 1 1 _. _.._ ._. ._ ---_-._ 1 � DUPLEX POWER OUTLET
0 1 CL 1 1 CL 1 N "N" DENOTES A NEW OUTLET �_�
1 EQ' EQ. 1 1 EQ. EQ 1 LADA BUILDING STANDARD ELEC. ADA DOOR OPE I
o QUADPLEX POWER OUTLET
+44" DENOTES HEIGHT AFF O
EXISTING FLOOR DRAIN I SHEET TITLE
FD
E ELECTRICAL SWITCH j 2ND FLOOR
o NEW WALL FIXTURE EUREKA 1 PLAN
N VCT PT DENOTES FLOOR FINISH TRANSITION. FLEX 34158, CF.D.26, 120V
F PLAN
Q 5 FINISH LOOK
°
1/411 = 1 ,-0,
SCALE
IV 1 141Cq 1/43
Q
E
,-' a
M LIMITS OF WORK
N
2ND FLOOR KEY PLAN
Uj N I
I,i 9
11 102
VG
■■■ GBDARCHIT'EC1Slncorporoted
2 1 OR 4"H. SOLID SURFACE
BACKSPLASH & RETURN
+ 1 2 FAUCET ASSEMBLY
WALL I 1 1 "x 2" CLEAT
PROVIDE AND INSTALL
2 -421-21`• _ 2 -8 -0 25—0 3• I I f1 1/2"x 1 1/2" STEEL
(,D3 FINISH EDGE SUPPORT CONTINUOUS ARCHITECTS
3
ALONG FRONT OF
COUNTERTOP, WELD TO
6
CL CLD/WR SND 8 - I ICL STEEL WALL SUPPORTS 1]20 NW Couch Street
� I Suite 300, Portland
4 -PROVIDE STEEL WALL 0 R 9 7 2 0 9
10 TILE BASE, PT-2 I I SUPPORTS, -1/2" STEEL
I J I I Tel: (503) 224.9656
7 ANGLE WELDED TO Yx
Fax: (503) 299.6273
TILE FLOORING, PT-1 +
I I 3'-0"x 1/8" STEEL PLATE www.gbdarchitects.com
WC2
7 T7q -C 0 1 ur-I
-I yp. CNI AT BOTH ENDS AND
C", I TlypCENTER, FASTEN SECURE
FIELD VERIFY TO METAL STUD
AR---" I +j I j C
PLUMBING CLEARANCES
A B C D N
PER ADA CODE W CRAJG AVIS
17 INTERIOR ELEVATIONS WOMENS 5 SECTION AT TILE BASE 1 SECTION AT LAV. COUNTER
PO I
1/4 HALF SIZE lot i I—opt PO ND, OREGON
3008 st,-
OF 0
SMOOTH FINISHED
CT-1 SOLID SURFACE
vEDGE
e2 —2 e- &\ e-2 3-811 �21—0 It,e_ ;29—ot PLAZA WEST
FINISH EDGE 3/4" SOLID Q Q, 2ND FLOOR RESTROOMS
--
%J SURFACE (W/ 4"
PLAZA WEST
al CL CL BUILT UP EASED
4 g
TD yr EDGE) W1 3/4' 9600 SOUTHWEST OAK ST
It TILE BASE, PT-10 MARINE PLYWOOD TIGARD, OREGON 97223
(D
62
in In
7j URJ 7 LKI TILE FLOORING, PT-1
-4-
=2 wcIU= go Typ. U=I VERIFY EXACT
C-4 ANGLE W/ SLOPE
FIELD VERIFY OF SINK
A B C D
18 INTERIOR ELEVATIONS MENS 6 SECTION AT TILE BASE 2 SECTION AT COUNTER EDGE
1/411 = 1 '-0" HALF SIZE HALF SIZE
54" MIN z 17" MIN 18" MIN ST-1
2 MAX " 42" MIN30 MI '01 ILI 8" MIN
9)1-41" 00 X ISSUED FOR PERMIT AND
-----------;11 V_ < TD/wR L31 CONSTRUCTION CN OCT.1,2012
,36" MIN 15' 01 z :2 —CUT TILE AS NEEDED
I , ", 12" MIN 0
24" MIN ABERREVIATION& —START RUNNING BOND
:z 60
Scd- m ADA 015 WtA15 SAft
URI v LAV UIC WATER CLOSET v
X X X SO -SOAP PUMM94SM INISHED EDGE, BOTH CORNER
< < IrO -TOILET PAMR 0ISFW4ft-R
< C) UR-URINAL
SO
LAV LAV- LAVATORY
U= X 2 SI,0 - 84NITAW NAFM PISMNSEife CT-2
< v is—3*) _t SC-SMITARr COVER DISPENSER TILE BASE, PT-1
M TDAR�-FbA15M TOWEL
dy r6>16PIDMRA"STE fvtACLE
TR- TRAW W-CaPTACIX I +_ CT-1
TILE FLOORING, PT 1
7-9 , 16"-18" 30� MN I-F.
0')
START
I
C
.o 4n
STANDARD ADA= ADA URINAL ADA LAVATORY ADA LAVATORY SAN. SEAT TOWEL ADA SOAP —CUT TILE AS NEEDED
11") STANDARD ADA W.C. STANDARD 11 1 1- 1 1 11 if
W.C. (FRONT) W.C. ADA MIRROR NAPKIN COVER DISPENSER f DOOR DISP. 17 -
(SIDE) DISPENSER DISPENSER WASTE OPERATOR Mid P4 PT-1 , ALIGN WITH
RECEPTACLE
TILE FLOORING
19 TYPICAL MOUNTING HEIGHTS 7 SECTION AT TILE BASE 3 TYPICAL WALL TILE LAYOUT REVISIONS
NOT TO SCALE HALF SIZE 1/41p DATE
FINISH SCHEDULE October 02, 2012
C CD WALL FINISH CASEWORK
i Room Room Floor Base Ceiling
OD Number i
PLAN REFERENCE NOTES Name Finish Finish Finish North East I South West Base Cabinets Countertop Upper Cabinets Comments PROJECT NUMBER
U PROVIDE AND INSTALL NEW GRAB BAR. PT-2
20031075
0) 200 CORRIDOR
C
29 Q PROVIDE AND INSTALL 5/8" GYPSUM BOARD OVER 5 REUSE SANITARY NAPKIN DISPENSER. 201 MENS PT-1 PT-1 P_1,CT_1 P_1,CT_1 P-1 ST-1 SS-1 TOILET PARTITIONS TO BE P-2
METAL STUD FURRING. 202 WOMENS PT-1 PT-1 P_1,CT_1 ST-1 P-1 P_1,CT_1 SS-1 TOILET PARTITIONS TO BE P-2
PROVIDE AND INSTALL NEW PAPER TOWEL
v, SHEET TITLE
E O PROVIDE AND INSTALL NEW LIGHT FIXTURE, EUREKA DISPENSER/WASTE RECEPTACLE INSET IN ORIGINAL FINISH LEGEND ELEVATIONS/DETAILS
FLEX341513, CF.D.26, 120V, FINISH: SC, FRO. LOCATION. PTD WR: GEORGIA PACIFIC, GP 59451 , CODE NAME MANUFACTURER DESCRIPTION
FINISH SCHEDULE
FINISH: STAINLESS STEEL.
00 PROVIDE AND IN-STALL NEW MIRROR. PT-1 PORCELAIN TILE PENTAL GRANITE&MARBLE MILESTONE,COLOR:CANYON,SIZE 12'X17
U_ SCALE
CT-1 CERAMIC TILE DALTILE DALK775.COLOR:BISCUIT,SIZE 4.25"X 8.5%PATTERN:RUNNING BOND
N ST-1 IC TILE LE SURFACE BULLNOSE S44C9, COLOR:K775 BISCUIT,SIZE 4.25!'X 8.5%PATTERN:RUNNING BOND AS SHOWN
n.
CT-2 CERAMIC DALTI
E P-1 ST-1 SLATE TILE PENTAL GRANITE&MARBLE CHINA MULTICOLOR, I X1 MOSAIC, FINISH: ENHANCER SEALER
SS-1 QUARTZ PENTAL GRANITE&MARBLE B08100P BOTTICINO,SIZE:3/4'"'SLAB,FINISH:POLISHED
oCT-1 , SEE DETAIL 3/A800 FOR TYPICAL LAYOUT.
C*4 C,4
GTA GROUT TBD TBD A800
6i C3 <j) CT-2 C14 P-1 GENERAL WALL PAINT -1—B—ENJAMIN MOORE COLOR:NAVAJO WHITE 947,FINISH SEMI GLOSS,NO V.O.C.
::I
C:> IP-2 PARTITION PAINT BENJAMIN MOORE COLOR:WILMINGTON TAN HC-34, FINISH:GLOSS,NO V.O.C.
< U
UO
L
GBIDARCHITECTSIncorporoted