Plans (22)[Page Too Large for OCR Processing] FPS 20 - p ©I 27 R(o 0 73 S w CaR st - 35 WEST PLAZA SUITE 350 9600 SW OAK ST. TIGARD, OR. 97223 ADDITIONS TO THE EXISTING FIRE ALARM SYSTEM DATASHEETS & CALCULATIONS Prepared by Fire Systems West, Inc. 600 SE Maritime Avenue Suite 300 • Vancouver, .WA 98661 (360) 693 -9906 V Fire Systems West, Inc I I I Designer: Rick Pagel 600 SE Maritme:Avenue #300 I I I I Vancouver, WA 98661 I I I I (360) 693 -9906 • I http: / /www.firesytemswest.com I I I This calculator provides voltage drop calculations in three formats (Point to Point, End of Line, and Load Centering). Make sure that you know what method is accepted by, and the results do not exceed the limits set by the respective jurisdiction I I I I Point to Point Method End of Line Method Load Centering Method Project Name Plaza West Suite 350 'CIRCUIT IS WITHIN LIMITS CIRCUIT IS WITHIN LIMITS CIRCUIT IS WITHIN LIMITS Job Number XXXX Date: 110/8/2011 Circuit Number 3 . I Totals Voltage Totals Voltage Totals Voltage Area Covered Suite 350 Sleep Lab Current Distance Drop Current Distance Drop Current Distance Drop Nominal System Voltage 20.4 1.872 152 0.75 1.872 152 1.747 1.872 152 0.874 Minimum Device Voltage 16 Wire Ohm's End of Line Voltage 19.65 End of Line Voltage 18.65 End of Line Voltage 19.53 Total Circuit Current 1.872 I Gauge I Per 1000 Percent Drop 3.70% Percent Drop 8.56% Percent Drop 4.28% Distance from source to 1st device 10 14 3.07 End of Line and Load Centering Methods use only the wire guage for the first device to source Wire Gauge for balance of circuit 14 3.07 Standard Wire Resistance in Ohms per 1000 feet. I Voltage I 18 =7.77 - 16 =4.89 14 =3.07 12 =1.98 10 =1.24 - I Current in amps. Distance 18 -14 Awg = Solid Conductors 12 -10 Awg = Stranded Conductors I I .150a = 150 ma from I I Notes: Device Device Candela Device previous At I Drop from I Percent 1. Wire resistance doubled in calcs for two wires.( Pos and Neg) Number Type, Rating Current device Device I source I Drop Device 1 PC2RH 177cd 0.290 10 20.29 0.115 0.56% 2. PC2RH 177cd = 0.290 Device 2 PC2RH 177cd 0.290 18 20.11 0.290 . 1.42% Device 3 PC2RH 177cd 0.290 32 19.86 0.544 2.66% 3. SR 15cd =.066 Device 4 PC2RH 177cd 0.290 10 19.79 0.605 2.97% Device 5 PC2RH 177cd 0.290 10 19.75 0.649 3.18% • Device 6 PC2RH 177cd 0.290 30 19.67 0.727 3.56% Device 7 SR 15cd 0.066 27 - 19.65 0.748 3.67% Device 8 SR 15cd 0.066 15 19.65 0.755 3.70% END 0.000 19.65 0.755 3.70% END 0.000 19.65 0.755 3.70% END 0.000 19.65 0.755 3.70% END 0.000 19.65 0.755 3.70% END 0.000 19.65 0.755 3.70% END 0.000 19.65 0.755 3.70% END 0.000 19.65 0.755 3.70% END 0.000 19.65 0.755 3.70% END 0.000 19.65 0.755 3.70% END 0.000 19.65 0.755 3.70% END 0.000 19.65 0.755 3.70% END 0.000 19.65 0.755 3.70% Totals I I I 1.872 I 152 'End of Line Voltage I 19.65 _ . . • *T SYSTEM \ \\ SENSOR' a ' 1 4 I Indoor Selectable- Output a E Horns, Strobes, and - Horn Strobes for Wall e. ', - �Tt ; ' , i Applications - it .. w SpectrAlert Advance audible visible notification products are rich with features guaranteed to cut SPECTRIert A D V A N C E installation times and maximize profits. Features The SpectrAlert Advance series offers the most versatile and • Plug -in design with minimal intrusion into the back box easy -to -use line of horns, strobes, and horn strobes in the industry. • Tamper- resistant construction With white and red plastic housings, wall and ceiling mounting options, and plain and FIRE - printed devices, SpectrAlert Advance can • Automatic selection of 12- or 24 -volt operation at 15 and 15/75 meet virtually any application requirement. candela • Field- selectable candela settings on wall units: 15, 15/75, 30, 75, 95, Like the entire SpectrAlert Advance product line, wall -mount horns, 110, 115, 135, 150, 177, and 185 strobes, and horn strobes include a variety of features that increase • Horn rated at 88+ dBA at 16 volts their application versatility while simplifying installation. All devices Rotary switch for horn tone and three volume selections feature plug -in designs with minimal intrusion into the back box, • making installations fast and foolproof while virtually eliminating • Universal mounting plate for wall units costly and time - consuming ground faults. • Mounting plate shorting spring checks wiring continuity before device installation To further simplify installation and protect devices from construction • Electrically Compatible with legacy SpectrAlert devices damage, SpectrAlert Advance utilizes a universal mounting plate with an onboard shorting spring, so installers can test wiring • Compatible with MDL sync module continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field - selectable candela settings, automatic selection of 12- or 24 -volt operation, and a rotary switch for horn tones with three volume selections. Agency Listings SIGNALING .-Tr CO 41> MEA riiia LISTED roved 71- 15'I R6 rnrlrhI APPROVED approved 7175 25 6 - 16.53 9 (horn nor s'rahst.o s es 54011 (chimes. horn ,;robes. horns) 3023572 M5A452 -054 chime strobes) 55517 (strobes) 7135-15531139 (horns. oh:mns) r SpectrAlert Advance Specifications Architect /Engineer Specifications General SpectrAlert Advance horns, strobes, and horn strobes shall mourn to a standard 4 x 4 x 11/2-inch back box, 4 -inch octagon back box, or double -gang back box. Two -wire products shall also mount to a single -gang J. x 4 x 1' -inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync•Circuir Module accessory, shall be powered from a non -coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 12 -volt -rated notification appliance circuit outputs shall operate between 9 and 17.5 volts; 24 -volt -rated notification appliance circuit outputs shall operate between 17 and 33 volts. Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full -wave rectified unfiltered power supply. Strobes and horn strobes shall have field - selectable candela settings including 15, 15/75, 30, 75, 95, 110, 1 15, 135, 150, 177, and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary - signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary - signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have three audibility options and an option to switch between a temporal three pattern and a non - temporal (continuous) pattern. These options are set by a multiple position switch. On four -wire products, the strobe shall be powered independently of the sounder.The horn on horn strobe models shall operate on a coded or non -coded power supply. Synchronization Module The module shall be a System Sensor Sync-Circuit model MDL listed to UL 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 4 " /16 x 4 " /16 x 21/23-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32 °F to 120 °F (0 °C to 49 °C) Humidity Range 10 to 93% non- condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR' Operating Voltage Range 8 to 17.5V (12 V nominal) or 16 to 33 V (24 V nominal) InputTerminal Wire Gauge 17 to 18 AWG Wall -Mount Dimensions (including lens) 5.6" L x 4.7 "W x 2.5 "D (142 mm L x 119 mm W x 64 mm D) Horn Dimensions 5.6" L x 4.7°W x 1.3 mm L x 119 mm W x 33 mm D) Wall -Mount Back Box Skirt Dimensions (BBS -2, BBSW -2) 5.9" L x 5.0 "W x 2.2 "D (151 mm L x 128 mm W x 56 mm D) Wall -Mount Trim Ring Dimensions (sold as a 5 pack) (TR- HS,TRW -HS) S.T L x 4.8 "W x 0.35 "D (145 mm L x 122 mrn W x 9 mrn D) Notes: 1. Full Wave Rectified (FWR) voltage is a non - regulated, time - varying power source that is used on some power supply and panel outputs. 2. P, S, PC, and SC products will operate at 12 V nominal only for 15 and 15/75 cd. • AVDS rco UL Current Draw Data . UL Max : Strobe Current Draw (mA RMS) • . UL Max: H Curr Dr (mA RMS) - 1 • 8 -17.5 Volts 16 -3 Volts 8 -17.5 Volts 16- 33_Volts •' _ Candela DC FWR DC FWR Sound Pattern dB DC FWR DC FWR Standard 15 123 128 66 71 Temporal High 57 55 69 . 75 Candela Range 15/75 142 148 77 81 Temporal Medium 44 49 58 69 • 30 NA NA 94 96 Temporal Low 38 44 44 48 75 NA NA 158 153 Non - temporal High • 57 56 69 75 95 NA NA 181 176 Non- temporal Medium 42 50 60 69 110 NA NA 202 195 Non - temporal Low 41 44 50 50 115 NA NA 210 205 Coded High 57 55 69 75 High 135 NA NA 228 207 Coded Medium 44 51 56 69 Candela Range 150 NA NA 246 220 Coded Low 40 46 52 50 177 NA NA 281 251 185 NA NA • . 286 258 . UL Max. Current Draw (mA RMS), 2 -Wire Horn Strobe, Standard Candela Range (15 -115 cd) 8 - 17.5 Volts 16-33 Volts DClnput 15 15/75 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 lemporal Medium 132 144 69 80 97 - 157 182 201 210 Temporal Low 132 143 66 . 77 93 154 179 198 207 Non - Temporal High • 141 152 91 100 116 176 201 221 229 Non Temporal Medium 133 145 75 • 85 102 163 • 187 207 216 Non Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non - Temporal High 142 161 103 112 126 181 203 221 229 Non - Temporal Medium 134 155 85 95 110 166 189 208 216 Non-Temporal Low 132 154 80 90 105 161 184 202 211' UL Max. Current Draw (mA RMS), 2 -Wire Horn Strobe, High Candela Range (135 -185 id) 16 -33 Volts 16 -33 Volts DClnput 135 150 177 185 FWR Input - 135 150 177 185 • Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non - Temporal High 255 270 303 309 Non Temporal High 233 248 275 281 Non - Temporal Medium 242 259 293 299 Non - Temporal Medium 219 232 262 267 Non - Temporal Low 238 254 291 295 Non Temporal Low 214 229 256 262 Horn Tones and Sound Output Data . Horn and Horn Strobe Output (dBA) _ 8 -17.5 16-33 24 -Volt Nominal • • Switch Volts Volts • Reverberant Anechoic Position Sound Pattern dB DC FWR DC FWR DC FWR DC FWR 1 Temporal I•ligh 78 78 84 84 88 88 99 98 2 Temporal Medium 74 74 80 80 86 86 96 96 3 Temporal . Low 71 73 76 .76 83 80 94 89 4 Non Temporal High 82 82 88 88 93 92 100 100 5 Non - Temporal Medium 78 78 85 85 90 • • 90 98 98 6 Non - Temporal Low • 75 75 81 81 88 84 96 92 7t Coded High 82 82 88 88 93 92 101 101 8t Coded Medium 78 78 85 85 90 90 97 98 9' Coded Low 75 75 81 81 88 85 96 92 t Settings 7, 8, and 9 are not available on 2 -wire horn strobes. AVDSOY o I 1 SpectrAlert Advance Dimensions 4 2.5" 5.05' =-•� r 2.23 1 r 1111 P f c 5.6" 5.98" a C OD a0 c �- C Wall -mount horn strobes Wall back box skirt SpectrAlert Advance Ordering Information Model Description Model Description Wall Horn Strobes Horns P2R "t 2 -Wire Horn Strobe, Standard cd', Red HR Horn, Red P2RIi" 2 -Wire Horn Strobe, High cd, Red HW Horn, White P2W" 2 -Wire Horn Strobe, Standard cd, White Accessories P2WH" 2 -Wire Horn Strobe, High cd, White BBS -2 Back Box Skirt, Wall, Red P4R" 4 -Wire Horn Strobe. Standard cd, Red BBSW -2 Back Box Skirt, Wall, White P4RH 4 -Wire Horn Strobe, High cd, Red TR -HS Trim Ring, Wall, Red P4W 4 -Wire Horn Strobe, Standard cd, White TRW -HS Trim Ring, Wall White Wall Strobes SR"' Strobe, Standard cd, Red SRH "t Strobe, High cd, Red SW Strobe, Standard cd, White SWH• Strobe, High cd, White Notes: • Add • -P' to model number for plain housing (no 'FIRE' marking on cover), e.g., P2R-P. t Add '-SP' to model number for •FUEGO• marking on cover, e.g., P2R -SP. t'Standard cd' refers to strobes that include 15,15/75, 30.75,95, 110, and 115 candela settings. "High cd' refers to strobes that include 135, 150, 177, and 185 candela settings. SYSTEM 07011 5ymem strew. 3825 Ohio Avenue • St. Charles, IL 60174 Andur, ton wnsna m change w.mm now, It,ren tem r,,,re,cm„rtr . $ SENSOR' Phone: 800- SENSOR2 • Fax: 630-377-6495 anent maxi ir(.mn«irreaa nog the latest versian ar rims data thett. AVD500600 • 4'Il. 42807 •