Loading...
Plans (9) 614 l° o - od s? • COOPER Notification Series RSS and RSSP Strobes and Strobe Plates RECEIVED M ► ' 2008 FIRE FIRE FIRE Oast _ FIRE . FIRE Series RSS Series RSS Series RSSWP RSS Round Description Features The Wheelock patented Series RSS Strobe Appliances and • Approvals include: UL Standard 1971, New York City (MEA), Series RSSP Strobe Plates have lower current draw while California State Fire Marshal (CSFM), Factory Mutual (FM), and maintaining outstanding performance, reliability and cost Chicago (BFP) See approvals by model in Specifications and effectiveness. These versatile appliances will satisfy virtually all Ordering Information requirements for indoor, wall or ceiling mount applications. • ADA/NFPA/UFC /ANSI compliant. Meets OSHA 29 Part Strobe options for wall mount models include 1575 or the 1910.165 Wheelock Patented MCW multi - candela strobe with field • Wall mount Multi- Candela models are available with Field selectable candela settings of 15/30/75/110cd or the high Selectable Candela Settings of 15/30/ 75/110cd or 135/185cd. intensity MCWH strobe with field selectable 135/185cd. Single Candela models are available in 1575cd Ceiling mount models include the patented MCC multi - candela Ceiling mount Multi - Candela models are ceiling strobe with field selectable intensities of 15/30/75/95cd or the high intensity MCCH strobe with field selectable available with field selectable candela settings of 15/30/75/95cd 115/177cd. or 115/177cd. (Round or Square) All models may be synchronized using the Wheelock SM, • Strobes produce 1 flash per second over the regulated voltage DSM Sync Modules, Wheelock Power Supplies or other range manufacturers panels incorporating the Wheelock Patented • 12 and 24 VDC models with wide UL "Regulated Voltage" us- Sync Protocol. Synchronized strobes can eliminate possible ing filtered (DC) or unfiltered VRMS input voltage restrictions on the number of strobes in the field of view. Wheelock's synchronized strobes offer an easy way to comply • Synchronize using the Wheelock sync modules or panels with with ADA recommendations concerning photosensitive epilepsy built -in Wheelock Patented Sync Protocol as well as meeting the requirements of NFPA 72. • Fast installation with IN /OUT screw terminals using #12 to #18 The Wheelock Series RSS Strobes employ a Patented Integral AWG wire Strobe Mounting Plate that can be mounted to a single gang, double gang, 4" square, 100mm European backboxes or the SHBB surface backbox. If the flush backbox has side or top space between it and the finished wall, the NATP (Notification For weatherproof Series RSS See Datatsheet S9004 Appliance Trimplate) may be used. It provides an additional .65" of trim for the Appliance. An attractive cover plate is provided for a clean, finished appearance on all models. The Series RSSP Multi - Candela Strobe Plates are a cost effective way to retrofit required wall strobe appliances to • bells, horns, chimes, multitones or speakers and easily mounts to standard 4" backboxes or for surface mount use with the Wheelock SBL2 surface backbox. • 4 4) (0 Ai> 1" 1 M EA APPROVED S5391 151 -92 -E 7125-0785:141 7300-0785:154 NOTE: All CAUTIONS and WARNINGS are identified by the symbol A. All warnings are printed In bold capital letters. A WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. VISIT WWW.000PERWHEELOCK.COM OR CONTACT COOPER WHEELOCK FOR THE CURRENT INSTALLATION INSTRUCTIONS. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND /OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND /OR OTHERS. • General Notes: • Strobes are designed to flash at 1 flash per second minimum over their "Regulated Voltage Range ". Note that NFPA -72 specifies a flash rate of 1 to 2 flashes per second and ADA Guidelines specify a flash rate of 1 to 3 flashes per second. • All candela ratings represent minimum effective Strobe intensity based on UL Standard 1971. • Series NS Strobe products are listed under UL Standard 1971 for indoor use with a temperature range of 32 °F to 120 °F (0 °C to 49 °C) and maximum humidity of 93% (t 2 %). • Series NH homs are listed under UL Standard 464 for audible signal appliances (Indoor use only). • "Regulated Voltage Range" Is the newest terminology used by UL to Identify the voltage range. Prior to this change UL used the terminology "Listed Voltage Range ". Table 1: Average RMS Current* RSS /RSSP - Wall Mount Ceiling Mount RSS /RSSP 241575W 24MCW 24MCWH 24MCC 24MCCH 24VDC Models - 1575cd 15cd 30cd 75cd 110cd 135cd 185cd 15cd 30cd 75cd 95cd 115cd 177cd UL max* 0.090 0.060 0.092 0.165 0.220 0.300 0.420 0.065 0.105 0.189 0.249 0.300 0.420 RSS /RSSP RSS /RSSP Wall Mount 24VDC 24VDC * RMS current ratings are per UL average RMS method. UL max current Models 121575W rating is the maximum RMS current within the listed voltage range (16 -33v for 24v units). For strobes the UL max current is usually at the minimum 12 vdc 0.152 listed voltage (16v for 24v units). For audibles the max current is usually at UL max' 0.255 the maximum listed voltage (33v for 24v units). For unfiltered FWR ratings, see installation instructions. Table 2: Audibles /Speakers for RSSP Strobe Plate Product Series Multitone Appliances AMT, MT Wiring Diagrams SERIES RSSIRSSP APPLIANCE Horns AH, NH, HS Motor Bells MB- G6/G10 PRECEDING ± APPLIANCE Speakers ET E70, ET70 APPLIANCE, SYNC OR EOLR Chimes CH70 MODULE, POWER ^ A SUPPLY OR FACP • SERIES RSS /RSSP APPLIANCES SYNCHRONIZED WITH DSM MODULE SINGLE CLASS "A" NAC CIRCUIT SERIES RSS /RSSP APPLIANCES SYNCHRONIZED WITH MULTIPLE DSM MODULES DSM DSM #1 STROBE + 0 +C DMZ NAC CIRCUIT SYNC Strobe NAC Cir. , m OUT r, 0 ____ � DSM #2 , $ 1041M �11NUS 1 �rl O + AUDIS Strobe NAC Cilf. + MINUS 2 DSM #3 TROBE • IN 2 Nozeit P Sync NAC + OUT 2 Strobe NAC Cir. ` t 'OXON CIRCUIT RETURN DSM Interconnecting wiring shown. Maximum of twenty (20) STROBE/PLATE ASSEMBLY AUDIBLE & VISIBLE APPLIANCE OPERATE IN UNISON SERIES RSSIRSSP APPLIANCE SYNCHRONIZED WITH SM MODULE SINGLE CLASS "B" NAC CIRCUIT TO NEXT SM FROM APPLIANCE - PRECEDING � - OR EOLR F 0 + STROBE APPLIANCE, SYNC IIi ^ St 2 - STROBE MODULE, POWER NAC �� SUPPLY OR FACP , /'1 C Circuit Q KOMI' STROBE AUDIBLE + P EOLR -Audible STROBE/PLATE ASSEMBLY SERIES RSS /RSSP APPLIANCES SYNCHRONIZED AUDIBLE & VISIBLE APPLIANCE OPERATE INDEPENDENTLY WITH PS - 12/24 - 8CP or PS - 12/24 - 8MP FROM + 1 Series PS -12/24 8MP PRECEDING T TO NEXT APPLIANCE OR _ APPUANCE FACP OR EOLR • OUTPUTS AS ri ® EOLR —' FROM + - — F 1 ' � — � — — — � + TO NEXT 4 PRECEDING STROBE OR STROBE, SYNC - — 1 r — — — — — EOLR A OR 010 MODULE, POWER 1 1 SUPPLY OR FACP C 2 - CLASS iii Eil m P STROBE APPLIANCE " For detail using SM or DSM Sync Module refer to Data Series PS- 12/24-8MP O' Sheet S3000 or Installation Instructions P83123 for SM and P83177 for DSM. For wiring information on the power supplies refer PS- 24 -8MC. Specifications and Ordering Information Order Wall Ceiling Non- Strobe 24 12 Color Color Square Agency Approvals Model Mounting Options"' or Code Mount Mount Sync Candela VDC VDC RED WHITE UL MEA CSFM FM BFP Round RSS - 24MCW -FR 940 X - X 15/30/75/110 X - X - B,D,E,F,G,H,J,N,O,R,X Square X X X X X RSS - 24MCW -FW 9401 X - X 15/30/75/110 X - - X B,D,E,F,G,H,J,N,O,R,X Square X X X X X RSS- 241575W -FR 7471 X - X 15 (75 on Axis) X - X - B,D,E,F,G,H,J,N,O,R,X Square X X X X X • RSS- 241575W -FW 7788 X - X 15 (75 on Axis) X - - X B,D,E,F,G,H,J,N,O,R,X Square X X X X X RSS- 121575W -FR 7476 X - X 15 (75 on Axis) - X X - B,D,E,F,G,H,J,N,O,R,X Square X X X X X RSS- 121575W-FW 7468 X - X 15 (75 on Axis) - X - X B,D,E,F,G,H,J,N,O,R,X Square X X X X X RSS - 24MCC -FW 3158 - X X 15/30/75/95 X - - X B,D,E,F,G,H,J,N,O,R,X Square X X X X ' RSS - 24MCC -FR 3157 - X X 15/30/75/95 X - X - B,D,E,F,G,H,J,N,O,R,X Square X X X X ' RSS- 24MCCR -FW 3160 - X X 15/30/75/95 X - - X B,D,E,F,G,H,J,N,O,R,X Round X X X X RSS- 24MCCH -FW 3461 - X X 115/177 X - - X B,D,E,F,G,H,J,N,O,R,X Square X X X X • RSS- 24MCCHR -FW 3463 - X X 115/177 X - - X B,D,E,F,G,H,J,N,O,R,X Round X X X X ' RSS- 24MCWH -FR 3465 X X 135/185 X X B,D,E,F,G,H,J,N,O,R,X Square X X X X • RSS- 24MCWH -FW 3464 X X 135/185 X X B,D,E,F,G,H,J,N,O,R,X Square X X X X RSSP-2475W-FR" 9013 X - X 180@ 77 °F W X X X - B,D,E,F,G,H,J,N,O,R,X Square X X X X • 75© -31°F RSSWP -2475W FW" 3034 X - X 180© 77 °F X X - X B,D,E,F,G,H,J,N,O,R,X Square X X X X ' 75@ -31°F RSSP- 121575W -FR 7798 X - X 15 (75 on Axis) - X X - D,E,Z Square X X X X X RSSP- 24MCW-FR 9402 X - X 15/30/75/110 X - X - D,E,Z Square X X X X X - RSSP- 241575W -FR 7793 X - X 15 (75 on Axis) - - X D,E,Z Square X X X X X *PENDING • All models sync with Wheelock SM, DSM or PS- 12/24 -8CP or PS- 12/24 -8MP. # Models are available in either Red or White. Call Customer Service for Order Code & Delivery. For Weatherproof Series RSS Strobe specifications see data sheet S9004. . ***Refer to data sheet S7000 for mounting options. Architects and Engineers Specifications The visual notification appliances shall be Wheelock Series RSS Strobe Appliances or approved equals. The Series RSS shall meet and be listed for UL Standard 1971 (Emergency Devices for the Hearing- Impaired) for Indoor Fire Protection Service. The strobe shall be listed for indoor use and shall meet the requirements of FCC Part 15 Class B. The strobe appliances shall produce a flash rate of one (1) flash per second over the Regulated Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged Lexan® lens. All inputs shall be compatible with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP). When Strobe Plates are to be installed, they shall be the Wheelock Series RSSP Strobe Plate and shall have the same electronic circuitry as the Wheelock Series RSS. The Series RSS Strobe shall be of low current design. Where Multi - Candela appliances are specified, the strobe intensity shall have field selectable settings and shall be rated per UL Standard 1971 at 15/30/75/110cd or 135/185cd for wall mount and 15/30/75/95cd or 115/177cd for ceiling mount. The selector switch for selecting the candela shall be tamper resistant. The 1575 candela strobe shall be specified when 15 candela UL Standard 1971 Listing with 75 candela on axis is required (e.g. ADA compliance). When synchronization is required, the appliance shall be compatible with Wheelock's SM, DSM Sync Modules, Wheelock Power Supplies or other manufacturers panels with built -in Wheelock Patented Sync Protocol. The strobes shall not drift out of synchronization at any time during operation. If the sync module or Power Supply fails to operate, (i.e., contacts remain closed), the strobe shall revert to a non - synchronized flash rate. The strobes shall be designed for indoor surface of flush mounting. The Series RSS Strobe Appliances shall incorporate a Patented, Integral Strobe Mounting Plate that shall allow mounting to single - gang, double -gang, 4 -inch square, 100mm European type backboxes, or the SHBB Surface Backbox. If required, an NATP (Notification Appliance Trimplate) shall be provided. An attaching cover plate shall be provided to give the Appliance and attractive appearance. The Appliance shall not have any mounting holes or screw heads visible when the installation is completed. The Series RSSP Multi- Candela or single candela Strobe Plate shall mount to either a standard 4 inch square backbox for flush mounting, or the Wheelock SBL2 backbox for surface mounting. All notification appliances shall be backward compatible. NOTE Due to continuous development of our products. specifications and offerings are subject to change without notice in accordance with Wheelock, Inc. standard terms and conditions. PIEMA Member WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY Made in USA SO410 RSS/RSSP 02108 NJ Location FL Location VA Location 273 Branchport Ave. 7565 Commerce Ct. P: 877- 459 -7726 Long Branch, NJ 07740 Sarasota, FL 34243 F: 703 - 294 -6560 P: 800-631-2148 P:941- 487 -2300 F: 732 - 222 -8707 F: 941- 487 -2389 www.coopernotification.com Cooper Notification is Wheelock ERN otification I. ;i3r.� SAFE WAV ES, � �" COO COOPER Notification Series NS Horn Strobes and Series NH Horns • ►HE F►KF �\ r Series NS Series NH Description: Features: The Series NS Horn Strobe Appliances are designed for indoor, • Approvals include: UL Standard 1971, UL Standard 464, wall and ceiling mount applications. New York City (MEA), California State Fire Marshal (CSFM), The Series NH Horn and the horn portion of the Series NS include Factory Mutual (FM) and Chicago (BFP). See approvals by a selectable continuous horn tone or temporal pattern (Code 3) with model number in Specifications and Ordering Information selectable dBA settings of 90 or 95 dBA. • ADA/NFPA/UFC /ANSI compliant Strobe options include 1575cd or the Wheelock patented • Complies with OSHA 29, Part 1910.165 Multi - Candela strobe with field selectable candela settings of • Wall mount model Field Selectable Candela Setting 15/30/75/110cd for wall mount and 15/30/75/95cd and 115/177cd 15/30/75/110cd (24 VDC Multi - Candela models) or 1575cd in for ceiling mount. 12 or 24 VDC These versatile Horn Strobe Appliances can be synchronized using ▪ Ceiling mount model Field Selectable Candela Setting the Wheelock SM, DSM Sync Modules, Wheelock Power Supplies 15/30/75/95cd and 115/177cd (24 VDC Multi - Candela or other manufacturers panels incorporating the Wheelock Patented Sync Protocol. Additionally, the audible may be silenced while models) maintaining strobe activation. • Selectable Continuous Horn or Temporal (Code 3) All models of the Series NS and NH are designed for maximum • 2 Selectable dBA settings of 90 and 95 dBA in both tones performance, reliability and cost- effectiveness while meeting or • Patented Universal Mounting Plate exceeding the latest requirements of NFPA 72/ANSI 117.1/UFC and UL Standards 1971 and 464 as well as meeting ADA requirements • 12 and 24 VDC models with UL "Regulated Voltage" using concerning photosensitive epilepsy. filtered DC or unfiltered VRMS input voltage The Wheelock patented 2 -Wire Series NS Horn Strobes and • Wall and Ceiling Mount Series NH Horns offer more features with lower current draw than • Ceiling models with same look as Wheelock round ceiling competitors. strobes and speakers • NH horn is selectable 12 or 24 VDC in 1 appliance • Synchronize using Wheelock Sync Modules or panels with built -in Wheelock Patented Sync Protocol • Fast installation with IN /OUT screw terminals using #12 to #18 AWG wires PEW gl) (5 110111 MEA l iiWr l APPROVED E5946 151 -92 -E 7125-0785:142 S5391 NOTE: All CAUTIONS and WARNINGS are Identified by the symbol A. All warnings are printed In bold capital letters. A WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. VISIT WWW.COOPERWHEELOCK.COM OR CONTACT COOPER WHEELOCK FOR THE CURRENT INSTALLATION INSTRUCTIONS. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, • INSTALLATION AND /OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND /OR OTHERS. General Notes: • Strobes are designed to flash at 1 flash per second minimum over their "Regulated Voltage Range ". Note that NFPA -72 specifies a flash rate of 1 to 2 flashes per second and ADA Guidelines specify a flash rate of 1 to 3 flashes per second. • All candela ratings represent minimum effective Strobe intensity based on UL Standard 1971. • Series NS Strobe products are listed under UL Standard 1971 for indoor use with a temperature range of 32 °F to 120 °F (0 °C to 49 °C) and maximum humidity of 93% (± 2%). • Series NH horns are listed under UL Standard 464 for audible signal appliances (Indoor use only). • "Regulated Voltage Range" Is the newest terminology used by UL to identify the voltage range. Prior to this change UL used the terminology "Listed Voltage Range ". Table 1: Ratings Per UL Standard 1971 Table 2: dBA Ratings for Series NS /NH Horn Regulated Reverberant dBA Anechoic dBA Input Voltage Strobe Candela @ 10ft per UL 464 @ 10 ft Model Voltage Range Description Volume VDC VDC /FWR ( 12 24 12 24 VDC VDC VDC VDC NS -24MCW 24 16.0 - 33.0 15/30/75/110 Continuous High 83 87 89 95 NS- 241575W 24 16.0 - 33.0 15 (75 on Axis) Horn Low 76 81 84 90 NS- 121575W 12 8.0 - 17.5 15 (75 on Axis) Code 3 High 79 82 89 95 NS -24MCC 24 16.0 - 33.0 15/30/75/95 Horn Low 72 76 84 90 NS- 24MCCH 24 16.0 - 33.0 115/177 Table 3: UL Max Current* Audible Wall Mount Strobe Models Ceiling Mount Strobe Models Series NS /NH NH -12/24 NS- 241575W NS -24MCW NS -24MCC NS- 24MCCH 24VDC @24VDC 15/75cd 15cd 30cd 75cd 110cd 15cd 30cd 75cd 95cd 115cd 177cd High (95) dBA 24VDC 0.044 0.104 0.074 0.107 0.184 0.244 0.082 0.124 0.209 0.275 0.350 0.477 Low (90) dBA 24VDC 0.018 0.096 0.066 0.101 0.177 0.232 0.071 0.114 0.201 0.261 0.306 0.429 Audible Wall Mount • RMS current ratings are per UL average RMS method. UL Series NS /NH NH -12/24 Aud /Strobe max current rating is the maximum RMS current within the listed 12VDC voltage range (16 -33v for 24v units). For strobes the UL max @12V NS 121575W current is usually at the minimum listed voltage (16v for 24v units). For audibles the max current is usually at the maximum High (89) dBA 12 VDC 0.021 0.220 listed voltage (33v for 24v units). For unfiltered FWR ratings, Low (84) dBA 12VDC 0.012 0.210 see installation instructions. • • . Wiring Diagrams° NS /NH APPLIANCE NS AND NH APPLIANCES SYNCHRONIZED WITH SM MODULE SINGLE CLASS "B" NAC CIRCUIT WITH AUDIBLE SILENCE • +❑ +❑ TO NEXT❑ FEATURE SM❑ FROND - - APPLIANCE❑ +OSTROBED PRECEDINGD V �� OR EOLR❑ �❑ 0 -OSTROBEO � � Str� APPLIANCE, SM /DSM,❑ �, 1111 PI A NACO o I ., , PS -24 -8MC OR FACPl7 circuitcuit y +❑ —• CD +Audib1e0 P ❑ EOLRO SIGNAL Audible0 Fivdib�eO NACO Circuit0 NS AND NH APPLIANCES SYNCHRONIZED WITH DSM MODULE DUAL NOTE: NS /NH must be set on Code 3 horn tone CLASS "A" NAC CIRCUIT WITH NO AUDIBLE SILENCE FEATURE to achieve synchronized temporal (Code 3) tone. DUAL SYNC MODULE Refer to installation instruction (P83983, P83600 08YNC respectively). OSYNC , " For detail using SM or DSM Sync Module refer OUT, I to Data Sheet S3000 or Installation Instructions 0.----- ,N — P83123 for SM and P83177 for DSM. For 0 ,, MINUS, - I wiring information on the power supplies refer to _4 Installation Instructions P84662 for PS -24 -8MC. F , !AUDIBLE A ■ SIGNAL C .. IRYIIIT All _ AUDIBLE P GLITZ. 1 . - 1 I+ 0 APPLIANCE APPLIANCE /� 0 1 �l/ MINUS SIGNAL 1 CIRCUIT RETURN SPECIFICATION & ORDERING INFORMATION Order Strobe Sync w/ SM, 12 Agency Approvals 24 Model Number Code Candela DSM or VDC VDC Mounting Options# PS- 24-8MC UL MEA CSFM FM BFP . NS- 24MCW -FR 9404 15/30/75/110 X X - B,D,E,F,G,H,J,N,O,R,X X X X X X NS- 24MCW -FW 9405 15/30/75/110 X X - B,D,E,F,G,H,J,N,O,R,X X X X X X NS- 241575W -FR 7806 15 (75 on Axis) X X - B,D,E,F,G,H,J,N,O,R,X X X X X X NS- 241575W -FW 7811 15 (75 on Axis) X X - B,D,E,F,G,H,J,N,O,R,X X X X X X NS-121575W-FR 7816 15 (75 on Axis) X - X B,D,E,F,G,H,J,N,O,R,X X X X X X NS- 121575W -FW 7818 15 (75 on Axis) X - X B,D,E,F,G,H,J,N,O,R,X X X X X X NH- 12/24 -R 7449 - X X X B,D,E,F,G,H,J,N,O,R,X X X X X X NH- 12/24 -W 7500 - X X X B,D,E,F,G,H,J,N,O,R,X X X X X X NS- 24MCC -FR 3754 15/30/75/95 X X - E X X X • NS- 24MCC -FW 3753 15/30/75/95 X X. - E X • X X • NS- 24MCCH -FR 3756 115/177 X X - E X • X X • NS- 24MCCH -FW 3755 115/177 X X - E X • X X • NH- 12/24R -R 3752 - X X X D & E X • X X •' NH- 12/24R -W 3751 - X X X D& E X • X X 'Pending Note: Models are available in Red or White. Contact Customer Service for Order Code and Delivery. #Refer to Data Sheet S7000 for Mounting Options NOTE: Due to continuous development of our products, specifications and offerings are subject to change without notice In accordance with Wheelock Inc. standard terms and conditions. • ARCHITECTS AND ENGINEERS SPECIFICATIONS The audible /visual notification appliances shall be Wheelock Series NS Horn Strobe appliances and Series NH Horn appliances or approved equals. The Series NS appliances shall meet and be listed for UL Standard 1971(Emergency Devices for the Hearing- . Impaired for Indoor Fire Protection Service). The Series NH Horn shall be UL Listed under Standard 464 (Fire Protective Signaling). The horn strobe shall be listed for indoor use and shall meet the requirements of FCC Part 15 Class B. All inputs shall be compatible with standard reverse polarity supervision of circuit wiring by the Fire Alarm Control Panel (FACP). The audible portion of the appliance shall have a minimum of two (2) field selectable settings for dBA levels (90 and 95 dBA) and shall have a choice of continuous or temporal (Code 3) audible outputs. The strobe portion of the appliance shall produce a flash rate of one (1) flash per second over the Regulated Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged Lexan lens. The Series NS shall be of low current design. Where wall mount, Multi - Candela appliances are specified, the strobe intensity shall have field selectable settings and shall be rated per UL Standard 1971 for 15 /30/75 /110 candela. Where ceiling mount, Multi - Candela appliances are specified, the strobe intensity shall have field selectable settings and shall be rated per UL Standard 1971 for 15 /30/75 /95 candela or 115 /177 candela. The selector switch for selecting the candela setting shall be tamper resistant. The 1575 candela strobe shall be specified when 15 candela UL Standard 1971 Listing with 75 candela on -axis is required (e.g. ADA compliance). When synchronization is required, the appliance shall be compatible with the Wheelock SM, DSM Sync Modules, Wheelock Power Supplies or other manufacturers panels with built -in Wheelock Patented Sync Protocol. The strobes shall not drift out of synchronization at any time during operation. If the sync module or Power Supply fails to operate, (i.e., contacts remain closed), the strobes shall revert to a non- synchronized flash -rate. The appliance shall also be designed so that the audible signal may be silenced while maintaining strobe activation. The Series NS Horn Strobes and NH horn shall incorporate a Patented Universal Mounting Plate that shall allow mounting to a single - gang, double -gang, 4 -inch square, 100mm European type backboxes, or the SHBB Surface Backbox. If required, an NATP (Notification Appliance Trimplate) shall be provided. All notification appliances shall be backward compatible. Member WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY Made in USA S2100 NS /NH 2/08 NJ Location FL Location VA Location • 273 Branchport Ave. 7565 Commerce Ct. 2009 North 14th St., Ste. 510 Long Branch, NJ 07740 Sarasota, FL 34243 Arlington, VA 22201 P: 800-631-2148 P: 941-487-2300 P: 877 -459 -7726 F: 732- 222 -8707 F: 941- 487 -2389 F: 703- 294 -6560 • www.coopernotification.com / Cooper Notification is Wheelock° \ COOPER Notification