Loading...
Permit (101) C 1 Y . - _ , TIGARD SITE WORK PERMIT r I DEVELOPMENT SERVICES PERMIT # : SIT2005 -00027 ,'6�Ix "' 13125 SW Hall Blvd., Tigard, O R 97223 503 - 639 -4171 DATE ISSUED : 11/17/2005 PARCEL : 1S135BD -00100 SITE ADDRESS: 09600 SW OAK ST ZONING : C -P SUBDIVISION: PLAZA WEST LOT: 005 JURISDICTION : TIG Project Description: Tap for 6" fire line to vault at property line & into bldg. CLASS OF WORK: NEW PAVING ?: U RESO. NO: TYPE OF USE: COM GRADING ?: N VALUE: 27,000.00 EXCV VOLUME: cy LANDSCAPING ?: N FILL VOLUME: cy SITE PREP ?: Y ENG FILL ?: N STORM DRAINS ?: N SOILS RPT REQD ?: N IMPERV SURFACE: sf Owner: FEES ASA PROPERTIES, INC Description Date Amount BY PAUL DEVILLE [BUILD] Prmt Fee - Valu 11/4/2005 $298.30 PO BOX 3110 [TAX] Valu 8% State Surcharg 11/4/2005 $23.86 HONOLULU, HI 96802 [BUPPLN] Pln Rv - Valu 11/4/2005 $193.90 [FLS] FLS P1n Rv 11/4/2005 $119.32 Phone: Total $635.38 Contractor: WESTERN STATES FIRE PROTECTION 13896 FIR STSTEB OREGON CITY, OR 97045 Phone: 503 -657 -5155 REQUIRED ITEMS AND REPORTS Reg #: LIC 104570 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable laws. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more than 180 days. ATTENTION: Oregon law requires you to follow rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952 - 001 -0010. through OAR 952 -001 -0100. You may obtain copies of these rules or direct questions to OUNC by calling 503 - 246 -6699 or 1- 800 - 332 -2344. _ — . ,, • I ssued By: Permittee Signatu 1 L I l i -i 1 al 1 \ \ ... I Call 503-639-4175 by 7:00 AM for an inspection that business day. Note: If you cannot schedule an inspection while the system is down, please call 503 - 718 -2433 for assistance. I This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. Site Work 76/ 0 Of Building Permit Application 0, FOR of I ICE USE oN.E. : u City of Tigard Recei v -ed 1- �� hate /B} -: // y 0. � �j - Perm 51 44-'1 7 1 S11 a Blvd., Tigard, OR 97 2 `� ,. Plan Review i.!�� Phone: 503.639.4171 Fax: 503.598.1960 � Other Permi��W(� 24495 - �d79 � Inspection Line. 503 63 ).4175 BBC 200 , y. . : _ I Date Date /B Ready / :y: Juris ® See Nape 2 for Internet: www.ci.tigard.or.us Yl! U 4 A 4 Notified /Method: I- I kr Supplemental Information CITY OF TIGARD n D *I4WISW REQUIRED DATA: 1- AND 2- FAMILY DWELLING El New construction El Demolition Permit fees* are based on the value of the work perfirrmed. Indicate the value (rounded to the nearest dollar) of all [ rNddition /alteration /replacement El Other: equipment, materials, labor, overhead. and the profit for the work indicated on this application. CATEGORY OF CONSTRUCTION PP on. • El I- and 2- family dwelling El Commercial /industrial Valuation: $ Accesso building Number of bedrooms: ry g ❑ Multi- family ❑ Master builder 1=1 Other: Number of bathrooms: �- JOB SITE INFORMATION AND LOCATION l otal number of floors: Job site address: q lC?0 () W (?MM -E6--- New dwelling area: square feet City/State/ZIP: th, iik_kZi / OR�- Garage /carport area: square feet Suite /bldg. /apt. no.: Project name: ' y U.D -r-- Covered porch area: square feet Cross street/directions to job site: Deck area: square feet Other structure area: square feet 1 REQUIRED DATA: ;COMMERCIAL CHECKLIST Subdivision: Lot no.: -728153 Permit fees* are based on the value oldie work performed. V" fax map /parcel no.: Indicate the value (rounded to the nearest dollar) of all equipment. materials, labor. overhead. and the profit Iitr the DESCRIPTION OF WORK \ work indicated on this application. AP ) i - M 1 k) L1 1L' �L Valuation: `S �_ V 1 -v Cr 'k-- Pr - 6Perz Lit el t�.) fo f G L_e Existing building area: square feet . ..1.31 -- c -But KA (1 New building area: square feet I3 PROPERTY OWNER ' ❑ TENANT Number of stories: 5 Name: ,p • Type of construction: ..-'K -- I R � l �U Address: Occupancy groups: City /State /ZIP: Existing: Phone: ( ) Fax: ( ) New: I- APPLICANT ❑ CONTACT PERSON NOTICE Business name: `, f '- V'V� t �R{v j - T„ r ' ��Qir Re,-E -n All contractors and subcontractors are required to he Contact name: ��)���t �jS licensed with the Oregon Construction Contractors Board under ORS 701 and may be required to he licensed in the Address: (32 (� -- ,-_ - y 5T jurisdiction in which work is being performed. lithe City/State/ZIP: o� C i l..i ,O2E6 t ,i (9 - o 4S applicant is exempt from licensing, the following reasons .! apply: Phone: (0 ( 5 S S Fax:: 3) (..,-1— Si E Z. E- mail:. VYI ,, r'IV Tcift1tJs 6' I. S P€ uS CONTRACTOR - - Business name: �J ;Iva C 1/K .AA--yo BUILDING PERMIT FEES* Address: Please refer to fee schedule. City /State /ZIP: s Fees due upon application a J, Phone: ( ) Fax: ( ) / Amount received & .7.-30 CCB lie.: 164S`IO Date received: J/ - v j ✓ Authorized signature: �j�� �� �' This permit application expires if a permit is not obtained l: V �`^"' C s w' within 180 days after it has been accepted as complete. Print nann 1) v v A.3 4L afk i i jS Date: I I /.4 l 0 5 * Fee methodology set by Tri- County Building Industry Service Board. ;: \Building \Permits \SIT- PermitApp.doc 12/03 440- 4013T(I I /02 /COM /WEB) November 9, 2005 Western States Fire Protection 7 y ) T c ; A A Tom Hutchins --a,'" -1 13896 Fir St. OREGON Oregon City, OR 97045 RE: PLAZA WEST — VAULT & FIRE LINES . ,✓ Project Information Building Permit: BUP2005 -00011 Occupancy Type:. - Tenant Name: Plaza West Construction Type: I -B Address: 9600 SW Oak St. Stories: ' S The plan review was performed under the State of Oregon Structural Specialty Code (OSSC) 2004 edition; 2004 Oregon Fire Code (OFC), NFPA.13.- -and the Tualatin Valley Fire & Rescue Fire & Life Safety Requirements for Fire Department Access and Water Supplies( TVF &R). The submitted plans are approved subject to the following. 1. The fire service main shall be flushed thoroughly, before connection to the system riser in order to remove foreign materials that ; mighthave entered the main during the course the installation. The flow rate shall'not be less than the water demand rate of the system. Section 10.10.2 \r 2. Hydrostatic testing of the underground piping "shall occur upon completion of work The contractor's material andNtest ertificate for underground piping shall be completed and signed. Copies shall be prepared for approving authorities, owners and contractor. Section 10.10.1x (All piping shall be inspected prior to backfill.) 3. All piping and attached appurtenances subjected to system working pressure shall be hydrostaticallytested at 200 psi (13.8 bar) or 50 psi (3.5,bar) in excess of the system working pressure, whichever is greater, and shall maintain that pressure without loss for 2 hours: Loss shall be determined by a drop in gauge pressure or visual leakage. The- testpressure shall be read from a gauge located at the low elevation point of the system or portion being tested. Section 10.10.2.2 4. The fire service main shall be minimum 36 inches below grade under driveways and 30 inches elsewhere. The depth shall be measured from the top of the pipe to finished grade. Section 10.4 5. When pipe must be run under buildings, special precautions shall be taken, including the following: ® Arching the foundation walls over the pipe ® Running the pipe in covered trenches 13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 TDD (503) 684 -2772 • ® Providing valves to isolate sections of pipe under building. NFPA 13, 10.6 6. Thrust blocks shall be placed between undisturbed earth and the fitting to be restrained and shall be capable of such bearing to ensure adequate resistance to the thrust to be encountered. Wherever possible, thrust blocks shall be placed so that the joints are accessible for repair. Section 10.8 7. Clearance shall be provided around all piping. The holes shall be sized 2 inches larger than the pipe for 1 -in nominal to 31 /2 -in nominal and 4 -in larger than the pipe 4 -in - nominal and larger. No clearance is required if flexible couplings are located within) ft of each side wall, floor, platform or foundation. Section 9.3.4. �r 8. Piping shall be listed for fire protection service and shall comply with-the. standards in Table 10.1.1 Approved Plans: 1 set of approved plans, bearing the City of Tigard.approval stamp, shall be maintained on the jobsite. The plans shall be available to:the Building Division inspectors throughout all phases of construction. 106.4.2 OSSC ?Y r Premises Identification: Approved numbers or addressesshall be provided for all new buildings in such a position as to be plainly visible and legible from the street or road fronting the property. 505 OFC When submitting revised drawings or additional information, please attach a copy of the enclosed City of Tigard, Letter of Transmittal. The letter of transmittal assists the City of Tigard in tracking and processing the documents. Respectfully, ' ` a ?o f Val Henze', .. Senior Plans Examine • tom. � CITY OF TIGARD BUILDING DIVISION PERMIT #: SIT200S- 00027 13125 SW Hall Blvd., Tigard, OR 97223 DATE ISSUED: 11/17/2005 Phone: (503) 639 -4171 I �iii Inspection Requests (24 Hrs.): (503) 639 -4175 °�_ INSPECTION WORKSHEET FOR DATE: 4/3/2007 TIME: 7:00AM PAGE: 80 SITE ADDRESS: 09600 SW OAK ST CLASS OF WORK: SUBDIVISION: PLAZA WEST LOT #: 005 TYPE OF USE: PROJECT NAME: PLAZA WEST DESCRIPTION: Tap for 6" fire line to vault at property line & into bldg. OWNER: ASA PROPERTIES, INC, PHONE #: CONTRACTOR: WESTERN STATES FIRE PROTECTION PHONE #: 503657 - 5156 Inspection Request Scheduled For: Date: 4/3/2007 Pour Time: Code # Inspectio. I escription Confirm # Contact # Message 435 M. . inspection • 7 , 045751 -01 360-907-1061 N Corrections /Comments /Instructions: • J '7 ? iF - 0.L11c , ; 6 -.AA /b pa-i r t cz iti'J( ? S P n PASS RTIAL APPROVAL �� CANCEL ❑ 7 NO ACCESS ❑ FAIL / , . LL FOR INSPECTION DDITI NAL FEES ASSESSED Inspector: _ �_ Date: v Phone #: 503 18- Z/ g p ) e. CITY ®1TIGARD BUILDING DIVISION PERMIT #: SIT2005.00027 13125 SW Hall Blvd., Tigard, OR 97223 'DATE ISSUED: 11/17/2005 Phone: (503) 639 -4171 Vit Inspection Requests (24 Hrs.): (503) 639 -4175 ..._.. INSPECTION WORKSHEET FOR DATE: 1/)J7007 TIME: 7 :00AM PAGE: 5 SITE ADDRESS: 09600 SW OAK ST CLASS OF WORK: SUBDIVISION: PLAZA WEST LOT #: 005 TYPE OF USE: PROJECT NAME: PLAZA WEST DESCRIPTION: Tap for 6" fire line to vault at property line & into bldg_ OWNER: ASA PROPERTIES, INC, PHONE #: CONTRACTOR: WESTERN STATES FIRE PROTECTION PHONE #: 503.557.5155 Inspection Request Scheduled For: Date: 1/2/2007 Pour Time: Code # Inspection Description Confirm # Contact # Message 420 Sprinkler supply lines 041697 -01 971-409-3148 .y Corrections /Comments /Instructions: PIC \ ( ipPe '19- --- Zc &------ n PASS .-- APPROVAL ❑ CANCEL ❑ NO ACCESS ❑ FAIL,. n CALL FOR INSPECTION ❑ ADDITIONAL FE, S ■ SSESSED IA i vr Inspector: / 0 D !' i P one #:. (503) 718- I\ -- CITY (WIJGARD BUILDING DIVISION PERMIT #: SIT200S-00027 13125 SW Hall Blvd., Tigard, OR 97223 DATE ISSUED: 11117/2005 Phone: (503) 639-4171 41,1111' Inspection Requests (24 Hrs.): (503) 639-4175 .;.1., INSPECTION WORKSHEET FOR DATE: 12/29/700 TIME: 7:00AM PAGE: 34 SITE ADDRESS: 09600 SW OAK ST CLASS OF WORK: SUBDIVISION: PLAZA WEST LOT #: 005 TYPE OF USE: PROJECT NAME: PLAZA WEST DESCRIPTION: Tap for 6" lire line to vault at property line & into bldg. OWNER: ASA PROPERTIES, INC, PHONE #: CONTRACTOR: WESTERN STATES FIRE PROTECTION PHONE #: 603-667-5155 Inspection Request Scheduled For: Date: 12129/2006 Pour Time: Code # Inspection Description Confirm # Contact # Message 420 Sprinkler supply lines 041632-01 503-657-5155 Corrections/Comments/Instructions: ODE,ki-- --(cY__kp 0 k) 17P-olikk Tre C(hE Cbtki w .011, 1111/ • .4 L1 4-4"- 7 41,0 _ `1.■ Avtil dry yr v \ I oait ' a II MO THIgUSr 11(38 DOS ( r6 n 'PASS PARTIAL APPROVAL CANCEL NO ACCESS n FAIL El CALL FOR INSPECTION LI ADDITI NAL F ES ASSESSED • f Inspector: Date: ZV Phone #: (503) 7102 for: Inspections Required for. S 17a O0S -- 000a- ✓ Code Inspection Description 1 PASS Date I By 1 I ✓ Code I Inspection Description 1 PASS Date 1 By j BUP - Building Permit ELC - Electrical Permit 405 Excavation 105 Underground/slab cover 1 410 Fill 110 Temporary electrical service + I 415 Grading 115 Electrical service 205 Footing 120 Electrical rough -in 805 MFG - Structure grading /footing 125 Wall cover 210 Foundation walls 130 Ceiling cover 215 Footing drain 135 Low voltage 220 Slab 140 Sign installation 1 310 Crawl drain 145 A/C or heating unit circuit 225 Post/beam structural 150 Hot tub /spa/pool 230 Underfloor insulation 195 Misc. inspection: 235 Shear walls /anchors 199 Electrical final 240 Exterior sheathing 245 Firewall • 250 Roof nailing ELR - Restricted Energy Permit 255 Wtr proofing basement walls 135 Low .voltage J 260 Tilt -up panel 195 Misc. inspection: 1 265 Masonry _ 199 Electrical final 270 Reinforcing steel (rebar) 275 Framing 810 MFG- Structure set -up MEC - Mechanical Permit i 280 Insulation 605 Post/beam mechanical 285 Drywall nailing 610 Gas line 287 Suspended ceiling 615 Mechanical rough -in . 295 Misc. inspection: 620 Hydronic piping 899 " MFG - Structure final 625 Duct work 498 Grading final 630 Fire damper 299 Final inspection 635 Smoke detector shutdown ' • 640 Exhaust hood 695 Misc. inspection: 699 Mechanical final BUP - Fire Protection System Permit 905 _Sprinkler underfloor /slab PLM - Plumbing Permit 910 Sprinkler rough -in 305 Plumbing underslab 915 Fire alarm rough -in 310 Crawl drain _ — 920 Suppression trip test 315 Post/beam plumbing _ 995 Misc. inspection: 320 Plumbing rough -in 998 Alarm final _ 325 RP/backflow preventer ■ 999 Sprinkler final 330 Water service 335 Rain drain 340 Storm drain SIT - Site Work Permit 505 Sanitary sewer 405 Excavation 345 _ Culvert/catch basin _ 410 Fill 350 Septic tank __ 415 Grading 395 Misc. inspection: 205 Footing 399 Plumbing final 210 Foundation walls 215 Footing drain K 420 Sprinkler supply lines SWR - Sewer Permit _ 495 Misc. inspection: 505 Sanitary sewer 498 Grading final 595 Misc. inspection: Yr 499 Final inspection 599 Final inspection I __ L \Rii 1dinQ \NR\InsoCard- AOP.doc 06/17/2005 CITY OF T SITE WORK PERMIT DEVELOPMENT SERVICES DATE ISSUED : 11/17/2005 027 13125 SW Hall Blvd., Tigard, OR 97223 503 - 639 -4171 PARCEL : 1 S1356D -00100 SITE ADDRESS: 09600 SW OAK ST ZONING : C -P SUBDIVISION: PLAZA WEST LOT: 005 JURISDICTION : TIG Project Description: Tap for 6" fire line to vault at property line & into bldg. CLASS OF WORK: NEW PAVING ?: U RESO. NO: TYPE OF USE: COM GRADING ?: N VALUE: 27,000.00 EXCV VOLUME: cy LANDSCAPING ?: N FILL VOLUME: cy SITE PREP ?: Y ENG FILL ?: N STORM DRAINS ?: N SOILS RPT REQD ?: N IMPERV SURFACE: sf Owner: FEES ASA PROPERTIES, INC Description Date Amount BY PAUL DEVILLE [BUILD] Prmt Fee-Valu 11/4/2005 $298.30 PO BOX 3110 [TAX] Valu 8% State Surcharg 11/4/2005 $23.86 HONOLULU, HI 96802 [BUPPLN] Pln Rv-Valu 11/4/2005 $193.90 Phone: [FLS] FLS Pln Rv 11/4/2005 $119.32 Total $635.38 Contractor: WESTERN STATES FIRE PROTECTION 13896 FIR STSTEB OREGON CITY, OR 97045 Phone: 503 - 657 -5155 REQUIRED ITEMS AND REPORTS Reg #: LIC 104570 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable laws. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more than 180 days. ATTENTION: Oregon law requires you to follow rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952 -001 -0010 through OAR 952 -001 -0100. You may obtain copies of these rules or direct questions to OUNC by calling 503 - 246 -6699 or 1- 800 - 332 -2344. Issued By:_4_ _ 4 _/ Permittee Signature: e1 )non CaII 503 - 639 -4175 by 7:00 a.m. for an inspection that business day. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. - , Tidemark Advantage Ilt ,f f, - I I� s x File Edit Options Window Help Exit New Open Task List QBE GIS © pi X. Z a la Close View Add Delete Sign Off Print Documents 1 el ... I ❑Ix1 Name:ASA PROPERTIES. INC Updated: 11;9..2005 VSH ner•.11 Address:09600 SW OAK ST Jur: ITIG Description: Master # 1SIT2005 -00027 Project: 'PLAZA WEST site Specifics Tap for 6" fire line to vault at property line & into bldg. Activity for SIT2005 -00027 fylem. Code Cu eated Datel Desci iption Datel Date2 Date3 I Disp Done By notes • 1110 11/09/2005 Approved plans routed to PT 11/9)2005 DONE VSH 1100 11 /09)2005 Building plans approved by PE 11/9/2005 APRV VSH 1060 11/09/2005 Building plans routed to PE 11/9/2005 DONE VSH plans came in the 4th unknown who roted them 1065 11/09/2005 Begin plan review 11/9/2005 VSH 1270 11/14Q005 Ready to issue permit 11/14/2005 REDY BB OK to issue per Paul I. 1280 11/17)2005 Issue permit 11/17/2005 DONE BB 1540 06/09/2006 Permit extension granted 6/9/2006 DONE HAP . 2420 12/28/2006 Sprinkler supply lines 12/28/2006 12/29/2006 12/29/2006 PART DAN 041632 -01 - 503- 657 -5155 - VM - N - 180 ■ 2420 01/01/2007 Sprinkler supply lines 1/1/2007 1)2)2007 1)2)2007 PART DAN 041697 -01 - 971- 409 -3148 - VM - Y -180 MEM 03129/2007 Misc. inspection 3/29/2007 4/30_007 4/3/2007 CNCL CB 045751 -01 - 360 -907 -1061 - VM - N -150 / 0 ■ 1 r Iv I , ' ofit pi i_C ",!--- ,,,- #1 4$XI'd ■ -, , ? (APf \ r\ 1 4-) I NN j l /r 11 / 0 4 . ■ .4 < I 1 l l I ■ I :;; Ready - 1 Start' 1 A... . Inbox - Micr... 1 _ - ,2 Desktop " « '' 8 :28 AM