Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Report (4)
OFFICE COP\ 5T Project: -Untitled242 03/03/2020 Prepared By: 02:57PM • RECEIVED goAl JUN 30 2020 CITY OF TIGARD BUILDING DIVISION 5T VALIDITY OF PERMIT THE ISSUANCE OF A PERMIT Tag Cover Sheet BASED ON CONSTRUCTION DOCUMENTS AND OTHER Unit Report DATA SHALL NOT PREVENT Certified Drawing THE CODE OFFICIAL FROM REQUIRING THE CORRECTION Performance Report OF ERRORS. OSSC 105.4 Unit Feature Sheet OFFICE COPY CITY OF TIGARD,,. REV' I D F'OF 1.U1)1? COM 'LIANCE Approved: ] OTC:• [ ] Permit #: r ne.c. a_hat) J OQ 9e.4-1 Address: J 37,Q.7 Pc.c.4'; G 1-44,-`l Suite #: By: •-f— - Date: 7-4,a0-- 253 Page 1 of 9 Packaged Rooftop Builder 1.497 Unit Report For 5T Project: —Untitled242 03/03/2020 Prepared By: 02:57PM Unit Parameters < Dimensions(ft.in.)&Weight(Ib.)*** Unit Model' 48FCDA06A2A5-0AOA0 Unit Length 6'2.375" Unit Size: , 06(5 Tons) Unit Width 3' 10.625" Volts-Phase-Hertz. 208-3-60 Unit Height 2'9.375" Heating Type* Gas **• Total Operating Weight 556 lb Duct Cfg: Vertical Supply/Vertical Return Low Heat *** Weights and Dimensions are approximate. Weight does not include unit packaging. Approximate dimensions are Standard One Stage Cooling Models provided primarily for shipping purposes.For exact dimensions and weights,refer to appropriate product data catalog. Lines and Filters Return Air Filter Type- Throwaway Return Air Filter Quantity 2 Return Air Filter Size* 16 x 25 x 2 Unit Configuration Direct Drive-EcoBlue-Medium Static Al/Cu-Al/Cu Base Electromechanical Controls Standard Packaging Warranty Information 1-Year parts(std.) 5-Year compressor parts(std.) 10-Year heat exchanger-Aluminized(std.) No optional warranties were selected. NOTE: Please see Warranty Catalog 500-089 for explanation of policies and ordering methods. Ordering Information Part Number Description Quantity 48FCDAO6A2A5-OAOAO Rooftop Unit 1 Base Unit Direct Drive-EcoBlue-Medium Static None Packaged Rooftop Builder 1.49z Page 2 of 9 Certified Drawing for 5T Project: —Untitled242 03/03/2020 - Prepared By: 02:57PM NOTES: �r IN11 I HGIFtt I[IRE r[aErll a 810 CLIMATE.IYlwls w¢rsswl w r¢¢wwlws ar:VW UNIT J I .... TMNONIEWRIYFfl tERENT.1 BE YIRNL01[erali r[4ao[rI�log w[[ainmC r1rt r[1Ia W CC OP 1. DINENSIDXS ARE IN INCHES, OINENIIONS 33 3/8 I8 5/B O Wrr„`r/•R[7wn WRITTEN[a¢¢. uc[nwa a w8iucr. IX I ]ARC IN NI LLIN510 NS. IBFW 0/ IBfl] [d121 CONNECTION SIZES 2.19 CENTER OF GRAVITY 48FGr03 33IB/11 3/8 14 7/8 I31T1 35-311--•.1 A 1 3/8• I351 SEA FIELD POSER SUPPLY HOLE 48FC106 33 3/8 118 - 3.y DIRECTION OF AIR FLOW fedll 14 13111 f8481 8 2' [SO DIA POWER SUPPLY KNOCKOUT RSFC o01 411051/8 3 1041 5/A2) 329IB ' ECONOMIZER HOOD ' C 1 3/4' (511 DIA GAUGE ACCESS PLUG [ 1 L 4. ED (( ALL VIES DRAWN USING 3110 ANGLE Mil IOPEI0NAL1 16 D 7/8'222)DIA FIELD CONTROL WIRING HOLE IIO11 E 3/4'-14 NPT CONDENSATE DRAIN ZS-SIB 16521 F 1/2'-14 NPT GAS CONNECTION RETURN AIR 1 6 2 1/2• [64] DIA POWER SUPPLY KNOCK-OUT i' . "....-0 • • ��'=� ♦ TNRU TNE-BASE CHART / ,�� C e 10-7/6 THESE HOLES REQUIRED FOR USE RET�l/a?—r��11 ) [2111 AIR UFN THREADED CREIR008A00•WINE ADD BUS'0 HOLE 0 /�// •I�`,``l`V\\4L�y/N qi. • •• CONDUIT SIZE USE SIZES IMA3.1 :i'�� �a 1- • - W 112' I ISY (I8' [22.2I 44-118 �.��. r 1/2' ZIV T/8' IUX.X1 f1120.91 ��' E ALI. [I4812 I 314• POWER 1.1/8' I28.11 1 CONDENSATE - 17-31/ ` 2• 1009A40)1/2'FPT 6AS 1-1/8' 128.6I 2 DRAIN OPENING I4511 + FOR•TNRU-THE-DASEPAN'FACTORY OPTION. \ IIIBAbf1AN SUPPLY 26.518 SUPPLE FITTINGS FOR ONLY 3, Y, b Z ARE PROVIDED 1 [I15]6-112 AIR [ (008A001 PROVIDES 314•FPT TARE CURB [369I 12-1/2 11-I/2 SEE TNRU THE •i - FLANGE 1.FITTING f3181 [2937 I BASE CHART 10-1/8 2%23-314 1 3-1/4 -6.1r4 I25S1 16031 [81] I1581 12-118 LUE I1011 WOOD [3011 8 2%25 18-3/8 It [6351 [/687 zz d-sle TOP [118] E STD, CONDENSATE 10-0/0 1 LECTRICAL DRAIN [2151 { [251 DISCONNECT •E-- LOCATION J vI1 iTIT ER CONDENSER I ,A,G OPTIONAL CONTROL L --- FACTORY ACCESS PANEL 263 COILINDOOR 11 3INSTALLED 1 5D1 M. OPTIONAL I �II DISCONNECT I r ACCESS PANEL 1- SUPPLYRAR _ INSTALLED (L/ HANGLE CONVENIENCE li I1i-� 11-118I!rUh - 4IIII II 6-5/8 11e1// 1/ f3021 ' [5391 OUTSIDE 1 NOR 410. — irMil [1681a ��Miii! HANDLE 5-3/4 MIMI 6-31D 3-3/4 46-5/8 8-3/8 I1161 11611 /177/ 11461 [95] [11 efi] 30-1 lg [2141 26-1/9 17661 I6921 14-3I8 31 BAROMETRIC LEFT I18891 17661 RELIEF FRONT SUPPLY FLOW AIR RETURN RIGHT AIR ITC CLASSIFICATION SHEET DATE SUPERCEOES 48FC 04-07 SINGLE PACKAGE ELECTRICAL REV U.S. ECCN:NSR 1 OF 3 09/07/18 06/22/1B COOLING WITH GAS HEAT 413TCOD3093 A Packaged Rooftop Builder 1.49z Page 3 of 9 Certified Drawing for 5T Project: —Untitled242 03/03/2020 Prepared By: 02:57PM 1/!� 1x16 MFUFn a FE IM1F6n OF urc cuWrt,[MIND/N aA6A1a{191 01 1X[s[ounlfa 01 NCulma �w �1W1Dl7n owns DILLY16Ul0°00 11ui0365 R nun ot1'W 090 M1 rol1Rlm6 PItT P[Iro1 0CC 0 910.UNIT CORNER CORNER CORNEA CORNER C.6. MEIGNi • =••Q1AC11 mim CORhm. ACRIRIA16F Of 6Nmu9T. UNIT WEIGHT 4 WEIGHT TAT WEIGHT III EIGHT ICI WEIGHT ED] LBS. NG. LBS. RI. LBS. KG. LBS. NG. LBS. NG. X Y 2 48F01104 402 219 113 51 116 53 128 58 125 51 37 5/6 19561 24 0/16 16241 18 1/4 1464] /RFC4405 543 246 133 53 133 60 133 60 138 63 36 1/2 19211 23 3/3 15941 18 14511 48FC4401 556 252 142 64 136 62 136 62 142 64 36 1/2 19211 23 3/8 15941 18 14511 48F0107 607 275 112 73 152 69 141 64 151 68 36 19146 22 1/2 15721 19 3/8(4921 *STANDARD UNIT WEIGHT IS WITN IO11 GAS HEAT AND❑TNOUT PACKAGING. FOR OTHER OPTIONS AND ACCESSORIES, REFER TO THE PRODUCT DATA CATALOG. 1 BACK R1? 1/2 WITH ECONOMIZER BACK [318] 1 , . _ WITHOUT \ ECONORIZER HOOD CORNER A CORNER B ECONOMIZER \ . } OPTIONAL DOOR •\1 fOPTIRNHO SWING a \ �,., sue:\1 ! RIGHT —(����l1�lllIlf1 '' 46„.4 8111111))0 . Tr.s.1--'7.--.A.:4 1 9 CORNER D ' " U CORNER C LEFT x TOP [18961 FRONT 1 I T�l NOTES: �J 1. FOR ALL MINIMUM CLEARANCES LOCAL CODES OR JURISDICTIONS MAY PREVAIL. . Z 1/!CIEARIFC6 SERVICE N7 SERVICE RII}! OPERATINGI l 1 SLRFALE CONDUCTIVE BAIRE R MBFCADUCTNE BARRER I7.FARANCE I�{ 6t FRFT 48 [1219mm7 36 [914mm] 18 [457mm) J ~"'� '�` LEFT 48 [1219mm] 42 [1067mm] 18 [457mm] FRONT BACK 4B [1219mm] 42 [1067mm] 18 E457mm7 BACK 1F/HOOD 36 1914011 36 [914mm] 18 [457mm] RK,1R 36 [914mm] 36 [914mm] 18 [457mm] TOP 72 [1829mm] 72 II 029RNn1 72 II029mm] ITC CLASSIFICATION SHEET DALE SUPERCEDES 18FC 04-07 SINGLE PACKAGE ELECTRICAL REV U.S. ECCN:NSA 2 OF 3 09/07/lB 06122718 CODLING WITH GAS HEAT 48TC003093 A Packaged Rooftop Builder 1.49z Page 4 of 9 • Certified Drawing for 5T Project: --Untitled242 03/03/2020 Prepared By: 02:57PM ��er IiG NmM 5 n nnW rt tl44J1 nmWS Wlrs m C.." mp 0 NW[rt ¢ 1Ni TEE CO VELD PI II DISCLOSES OV USED ps0 Wm[rvC[ NrXr[A W 0....Y.........IIIN%SUMS SEISM 71-118 I1805.31 (INSIDE THE BASE RAIL&SKIRT) I 0 fr Al 41-1f1 [1016,51\ 0.....r O !INSIDE THE BASE ROI L51- 1 G� i ' � p2-111 I5l]\� a11 I/\ ' , APIJI m 1 6 - % 2%1-311 '11111� � /�p- INSIDE BASERAIL DIMENSIONS 1161 �1 0" 2%1-TNB BOTTC)M 1181 ' ZX 2- 1 316 2%1 1-1f1 1361 I251 I821 21 319 311B ,.— (18] DETAIL C E991 TYP 4 PLCS FILTER ACCESS PANEL CORP. CONDENSER CONTROL BOX INDOOR BLOWER I TOOL-LESSI ACCESS COIL ACCESS PANEL ACCESS PANEL . PANEL . U I1 M INDOOR COIL Y( ACCESS PANEL I—. 1'� I• a EE DETAIL C • I= a 1a110 - Q .1 (� 1' �0 1 f t'rl." � 11' r 1 o6'.I I E_,I I' I 1 .d n (l 1.1 I T r l .1 1' 1 I(061- BACK LEFT 3-1/1 59JI6 \ / I82.01 II509.01 —.' '..--2-3B T-1/8 I61.51 [180.11 TOP CURB FRONTWIDTH ITC CLASSIFICATION SHEET DAZE SUPERCEDES /BFC 04-01 SINGLE PACKAGE ELECTRICAL REV I U.S. EGEN:NBN 3 OF 3 09/0Tl18 06122/1B COOLING WITH GAS HEAT 48TC083093 A Packaged Rooftop Builder 1.49z Page 5 of 9 Performance Summary For 5T Project: -Untitled242 03/03/2020 Prepared By: 02:57PM Part Number:48FCDA06A2A5-0A0A0 ARI SEER' 14.00 Base Unit Dimensions Unit Length. 74.4 in Unit Width' 46.6 in Unit Height 33.4 in Operating Weight Base Unit Weight' 556 lb Total Operating Weight' 556 lb Unit Unit Voltage-Phase-Hertz. 208-3-60 Air Discharge' Vertical Fan Drive Type' Direct Actual Airflow' 2000 CFM Site Altitude' 0 ft Cooling Performance Condenser Entering Air DB' 95.0 F Evaporator Entering Air Da 80.0 F Evaporator Entering Air WB• 67.0 F Entering Air Enthalpy _31.44 BTU/lb Evaporator Leaving Air DB. 59.3 F Evaporator Leaving Air WB' 57.7 F Evaporator Leaving Air Enthalpy 24.85 BTU/lb Gross Cooling Capacity' 59.31 MBH Gross Sensible Capacity: 44.73 MBH Compressor Power Input. 4.14 kW Coil Bypass Factor 0.163 Heating Performance Heating Airflow' 2000 CFM Entering Air Temp' 70.0 F Leaving Air Temp' 95.0 F Gas Heating Input Capacity' 67.0 MBH Gas Heating Output Capacity' 54.0 MBH Temperature Rise' 25.0 F Thermal Efficiency(%)' 81.0 Supply Fan External Static Pressure' 0.75 in wg Fan RPM' 2125 Fan Power 1.02 BHP NOTE. Selected IFM RPM Range:239 -2390 Electrical Data Voltage Range' 187 -253 Compressor#1 RLA 16 Compressor#1 LRA• 110 Indoor Fan Motor Type' MED Indoor Fan Motor FLA 8.6 Combustion Fan Motor FLA(ea)' 0.48 Power Supply MCA' 31 Power Supply MOCP(Fuse or HACR)' 45 Disconnect Size FLA- 30 Disconnect Size LRA• 126 • Electrical Convenience Outlet None Packaged Rooftop Builder 1.49z Page 6 of 9 Performance Summary For 5T Project: -Untitled242 03/03/2020 Prepared By: 02:57PM Outdoor Fan [Qty/FLA(ea)] 1 /1.5 Control Panel SCCR: 5kA RMS at Rated Symmetrical Voltage Acoustics Sound Power Levels,db re 10E-12 Watts Discharge Inlet Outdoor 63 Hz 92.6 89.0 85.6 125 Hz 84.0 79.8 84.7 250 Hz 78.0 72.1 80.5 500 Hz 74.4 66.6 76.0 1000 Hz 71.2 68.6 72.4 2000 Hz 68.9 60.2 68.0 4000 Hz 64.6 53.2 62.8 8000 Hz 60.5 47.6 59.3 A-Weighted 77.8 72.5 79.0 Advanced Acoustics • a ,� Advanced Accoustics Parameters 1. Unit height above ground: 30.0 ft 2. Horizontal distance from unit to receiver 50.0 ft 3. Receiver height above ground• 5.7 ft 4. Height of obstruction' 0.0 ft 5. Horizontal distance from obstruction to receiver:-_.-_0.0 ft 6. Horizontal distance from unit to obstruction- 0.0 ft Detailed Acoustics Information Octave Band Center Freq. Hz 63 125 250 500 1k 2k 4k 8k Overall A 85.6 84.7 80.5 76.0 72.4 68.0 62.8 59.3 89.2 Lw B 59.4 68.6 71.9.72.8 72.4.69.2 63.8 58.2 78.5 LwA C 53.2 52.3 48.1 43.6 40.0 35.6 30.4 26.9 56.8 Lp D 27.0 36.2 39.5 40.4 40.0 36.8 31.4 25.8 46.1 LpA Legend A Sound Power Levels at Unit's Acoustic Center, Lw - B A-Weighted Sound Power Levels at Unit's Acoustic Center, LwA C Sound Pressure Levels at Specific Distance from Unit, Lp D A-Weighted Sound Pressure Levels at Specific Distance from Unit, LpA Packaged Rooftop Builder 1.49z Page 7 of 9 Performance Summary For 5T Project: —Untitled242 03/03/2020 Prepared By: 02:57PM Calculation methods used in this program are patterned after the ASHRAE Guide; other ASHRAE Publications and the AHRI Acoustical Standards. While a very significant effort has been made to insure the technical accuracy of this program, it is assumed that the user is knowledgeable in the art of system sound estimation and is aware of the tolerances involved in real world acoustical estimation. This program makes certain assumptions as to the dominant sound sources and sound paths which may not always be appropriate to the real system being estimated. Because of this, no assurances can be offered that this software will always generate an accurate sound prediction from user supplied input data. If in doubt about the estimation of expected sound levels in a space, an Acoustical Engineer or a person with sound prediction expertise should be consulted. FanCurve V 24 ?O3FFM ` :DOD IP 22 21 • a�aamn \ T17 NN '- in 15 T 1.4 z - Ni ` \ U 12 to 1D 1400FdM m12ourm �\ \,,,, 03 \ ,t. \ \ 06 C14 ECCIFFIV .\\\ 02 \ ODJET— I I I �l \ I �L I\ 00 02 Q1 O6 05 10 12 14 16 18 20 22 24 2i 28 30 Airllav(CFM-thousands) RPM=2125 BHP=1.02 Max mumRPM=2836Maxim rnBHP=3.00 SC-SystemCurveRP-RatedPoint Packaged Rooftop Builder 1.49z Page 8 of 9 Unit Feature Sheet for 5T Project: --Untitled242 03/03/2020 Prepared By: 02:57PM Ccilarrieer WeatherMakee -48 F C PACKAGED ROOFTOPGASHEATINGiELECTRICCOOLINGUNiTS- 14SEER3,4,5TONS,15IEER6Ton .. STANDARDFEATURESINCLUDE: ._ Purn(R410A)HFCrefrigerant ,. . Meelsare> sASHRAE90.1e nag icy b,- c „.. „ r .-` F9 , Saticcmpress rswitV�nallnebreakanziaer p f l ! x :ja r • a 4... r 04- rrukt.,,TwoSF geon07mod elsi 1I SEERsto14.0,1EER5b15.0 -V Paitrolrel'geranlmeterirgsysternon04-06ntodeFaTXVon07 n h i:; f sizenodeb naraidar¢ Fi jog* t,� ASHRAEShandard62,slopirg dawn,sidearoenterdrain Standadmcfngoper'afia uptol 15°F(46°C)anddoMrb40°F(4°C) -da rm to25°F(-4'C)withwinterstartldt Prepaintede>teriorp ardpmrr-coatedintenorpaneistestedto 500hdussaltspaypratectm Fulyii sulaitedcabinet NEWDiredDrive-FrrW reTechnologyinrk:oriansystem uses IISHRAC "NewUnCor ldwil i ,s a usment UExdrsvelGCsofd�aleoontreifororrl rddcgrosticswhLE D eiruiwdedesgnalonbumerarNdbgcCOMPLIANT Irduceddraftgasheato mbratimdesigi Reandartgasvaloaswhuptatwogagesoftlealng Lowpressmandhighpressureswldiprotected. MAINrENANCEFEATURES: Acoasspandsvaleasygrphandles VEAll-ER11,46KEREBRES Irvavafrveeasystating.nostripsaersonunitaoxsspanels Two-indtdisposableretumairfltersandTooHessfilterarrsdoor t Newurdtwntrolboanitofadllatesinple:afelydrrui[houbi8shoodng cooirgulEttrtaBpemiedancichargaiwihRrn andsimpifiedoaNdboxarraigement (R410)religerantlhetrisaetadayestednholh INSTALLATION FEATURES: lhu-thebottappcmerentrycepatity Ltd_ Shglepointgasandetsdricoonnedions Fulpedmeterbaserailwithbuitanriggirgadaptersandfarksbis Field caivatiblefromertlaltol uii oMlairtwd STANDARDWARRANTY: l ayeaheatexdiarger-1 rrleasOiriesss-hp-cn Appovetrrberrifiect7 3-tearSystemVu 1-yearpats �i CERTIFIED. Marryoptionalupgradesalsoavaiatie Use am•amiGelled° OPTIONS INCLUDE BUTARE NOT LIMfTEDTO: C (DI US TAMMNac•bsa • InRr�gent5ysemW xaI D arr sos manes • RTUOpatMutiRubmIDDCCmtrols n• san�a m• wwam co,wanton • ScpplyardRtlurrNfSrtlolrEDetector°'.higlttifia&:.rrKAdCrS am4M0Vn ro,individual • bouvEndcondensercaguards .,•ona a,e. • DSartnsdsniMia cborneniakeoukopi ats • Sraitless. texchargerop6cn • Gcm3sion resistantailcoaling. • MERV-8RetumAirF3trars • Pala dedHunidFMZer ®adaphveddxxnidkationsystem. - • Hngedapanels • tr abdearanaersysternt.avadUlaLavl,eai erdors • PhaseManilxRotedion . Fora oompleteistdcptionsarrlaccessaiwerefel tutheProductData Catalogfonhisrarit Packaged Rooftop Builder 1.49z Page 9 of 9 RECEIVED _ _ JUN 30 20� DIEGOCITY-ABUILDING DIVISION Oregon Aire, Inc. 7715 NE 33rd Drive, Suite A P: 503-335-2222 Portland, Oregon 97211 E: permits@oregon-aire.com Existing Unit versus New Unit Weight & Dimensions Site Address: 13727 SW Pacific Hwy. Suite 200 Tigard, OR 97223 Job Location: Tigard Retail Center - Rovente Pizzeria Existing Unit Information: Mfr:Carrier M/N:48DJD006520 j S/N: 2590G81765 Unit Weight: 594 Lbs Curb Weight: 115 Lbs Total Weight: 709 Lbs Unit Height: 38" Curb Height: 13" Total Height: 51" New Unit Information: Mfr: Carrier M/N: 48FCDA06A2A5-0A0A0 S/N: N/A Unit Weight: 591 Lbs Curb Weight: 115 Lbs Total Weight: 706 Lbs Unit Height: 36" Curb Height: 13" Total Height:49" Notes: Using existing curb. Unit weights include economizers. l Product 48DJD/DJE Data Single-Package Rooftop Units RECEIVED Electric Coolin m g/Gas Heating 11, HEATING&COOLING JUN 30 2020 CITY OFTIGARD 3 to 12-1/2 Nominal Tons RUII DING nllnslnN 'Ey14hr U •vc44 ti , . Single-Package Rooftop Units with the Following Premium Features as Standard: • 2-in, return-air filters • direct spark ignition • induced draft fan • Turbo-tubular'" heat exchangers • solid-state controls • full-perimeter base rails • high-pressure, low-pressure/loss- of-charge cutout switches and freeze protection thermostat • corrosion-resistant condensate pan with internal trap • refrigerant filter driers • • galvanized steel cabinet with r • painted protection on externally F. 5<�d q:Z. 1,,�0 ,, .' 1. exposed surfaces ° 2 > f% ,,.; , • p motors with permanently lubricated YF by ,�„ae.,. ' , r . ball bearings ball v.-4,.\._ Wog. � ;%�:�$ 4* , ; M Features/Benefits 5 4ra.o- R Compact, vertical discharge > units easilyconvert to mo ' C , rti horizontal ischar e, com- { . ( bining installation flexibility >,r au �° with efficient performance r= and easy maintenance A P t.' Easy maintenance and . installation All units are factory shipped in the ver- tical discharge configuration for fit- up to standard roof curbs. (One accessory curb fits sizes 004-007; an- other accessory curb fits sizes 008- 014.) The contractor can order and install the roof curbs early in the con- struction stage, before decisions on size requirements have been made. All units feature roll-formed baserail design with forklift slots and rigging holes for easier maneuvering. Stretch- wrap packaging protects the unit during shipment and storage. Copyright 1991 Carrier Corporation Form 48DJ-4PD wi ,.+. An•m"„ouni ~' Units are easily converted from verti- The induced draft combustion sys- - protection switch which allows opera- ' • cal to horizontal applications to make tern eliminates the unsightlyappear- fion at lower ambient conditions retrofit and add-on jobs easier To ance of flue stacks, and diminishes while protecting against low-charge op- convert from vertical to horizontal dis- the effects of winds on heating opera- erafion; 2) freeze protection thermo- charge, simply move 2 panels. The fion. The inducer fan draws hot stat, which protects against evaporator same basic unit can be used for a vari- combustion gas through the heat ex- coil frost build-up; 3) high-pressure ety of applications and can be quickly changer at the optimum rate for the switch, which protects against above • modified at the jobsite. most effective heat transfer normal operating pressure; 4) replace- Ductwork connections are made The direct spark ignition system able filter driers, which trap moisture easy by the logical 2 to 1 aspect ratio. saves operating expense when corn- and dirt; and 5) Carrier's exclusive On vertical discharge units, duct- pared to old-style pilot ignition systems Acutrol" metering device, which pre- work attaches directly to the roof curb. No crossover tube is required, there- cisely controls refrigerant flow, pre- Accessory thru-the-curb service con- fore no sooting or pilot fouling venting slugging and floodback, while nections allow power, gas and control problems can occur.All ignition compo- maintaining optimum wiring to be routed through The curb, nents are contained in a compact unit performance. thereby minimizing roof penetrations. module that is easily accessible for ser- Varislide" economizer permits low- Both power and control connec- vice Standard units are designed for cost operation by utilizing cool out- lions are made on the same side of the natural gas. An LP conversion kit door air for free cooling Reliable sliding unit to simplify installation. is available as an accessory, if required. plate damper is easily adjusted for The Drain Guard'' non-corrosive A solid-state control system is 100% outdoor air, 100% return air or condensate drain is factory installed and readily adaptable to all conventional any proportions of mixed air. Econ- internally trapped. This eliminates and programmable thermostats In ad- omizer operation is controlled by the need for a field-supplied conden- dition, units are suitable for Integra- Accusensor" I dry-bulb thermostat sate drain,savingtime and lion into monitor control systems if which senses outdoor air temperature. money. y Standard 2-in. throwaway type fiI- required. Optional accessory upgrade kits in- clude Accusensor" II solid-state ters are easily accessed through a Refrigerant circuit protection assures enthalpy control and Accusensor"' III hinged access door located directly dependability All units have Stan differential enthalpy control above the air intake hood; no tools are dard: 1) loss-of-charge/low-pressure required to change the filters. Rounded corners on panels help to prevent Table of contents damage or puncture of roof materials. Table Weather-resistant cabinet is coated Page with a pre-painted enamel finish Model Number Nomenclature . . . . . 2 on all externally exposed surfaces to ARI Capacities 3 • ensure long life and attractive Physical Data 4, 5 appearance. Options and Accessories. . . 6, 7 Base Unit Dimensions 8,9 Quiet, efficient operation and Accessory Dimensions. . . . . . . . . . . . . . . . 10,11 dependable performance Selection Procedure . . . 12 Compressors are fully hermetic with in- Performance Data 13-24 ternal vibration isolators for extremely Electrical Data. . . . . . . . . . . 25 quiet operation. Efficient condenser Typical Piping and Wiring 26 fan and motor design permits opera- Application Data . . 27 lion at a low sound power of 8.2 bels Typical Control Wiring Schematic . . . . . 28,29 for sizes 004- 007, 8 6 bels for sizes Controls 29 008, 009 and 014 and 8.8 bels for size 012. Guide Specifications 30-35 All coilse copperenhanced tubiri and are IV' completely degreased before leav- ing the factory to eliminate coil blowoff problems. Condenser coils have buy- 48 DJ E 004 - 3 0 1 AA ered aluminum fins providing max- imum heat transfer for optimum 48—Gas Heat efficiency DJ—Constant Volume FIOP Code* Turbo-tubular" heat exchangers op- timize heat transfer for improved effi- D—Low Heat Packaging ciency. The tubular design permits E—High Heat hot gases to make multiple passes - Series across the path of the supply air. In ad- Nominal Capacity - dition, turbolators inside the heat ex- 004—3 Tons 008 — 71/2 Tons 1 —575-3-60 changer tube act as baffles, forcing 005—4 Tons 009 —81 Tons 3—208/230-1-600 the hot gases to stay in close contact 006—5 Tons 012 —10 Tons 5—208/230-3-60 with the cell walls and improving heat 007—6 Tons 014 —121/2Tons 6—460-3-60 transfer. *Refer to 48DJ price pages for Flop (Factory-Installed Options) code table. ® 2 i . AR1* capacities NET COOLING SEER} SOUND UNIT MODEL NOMINAL STANDARD CAPACITY(Btuh) TOTAL EER RATING - 48 TONS CFM Single-Phase Three-Phase kW With Without (Reis) Units Units Timer** Timer DJE004 3 1200 34,800 34,600 4.1 9 7 9 5 8 4 8 2 DJD/DJE005 4 1600 48,000 48,000 5.8 9 3 9 1 8 3 8 2 DJD/DJE006 5 2000 60,000 59,500 7.0 9.5 9 3 8.6 8.2 NET UNIT MODEL NOMINAL STANDARD COOLING TOTAL EER SOUND RATING IPLV 48 TONS CFM CAPACITY kW (Bets) (Btuh) DJD/DJE007 6 2400 71,000 845 8.4 8.2 • tt DJD/DJE008 71 3200 89,000 104 8.5 8.6 tt DJD/0JE009 81 3400 100,000 11 2 8 9 8.6 tt DJD/DJE012 10 4000 118,000 137 86 8.8 tt DJDO14 121/2 5000 144,000 17.5 8.2 8.6 7 9 LEGEND Rated in accordance with ARI Standards 210/240-89 or 360-86 (014 units)and 270-84 Bels — Sound Levels(1 bel = 10 decibels) EER — Energy Efficiency Ratio - IPLV — Integrated Part-Load Value �/��J. " SEER - Seasonal Energy Efficiency Ratio ©I. : 9 lizIN „„,,,„,„,... *Air-Conditioning&Refrigeration Institute. }Applies only to units with capacity of 65,000 Btuh or less. Ratings are net values,reflecting the effects of circulating fan heat Rat- SEER ratings with timer are made using time delay relay part number ings are based on; HN67SK031. Cooling Standard: B0 F db, 67 F wb indoor entering-air temperature tribe IPLV is not required by certification agencies for 10-ton or smaller and 95 F db air entering outdoor unit units. iHEATING CAPACITIES AND EFFICIENCIES UNIT OUTPUT CALIFORNIA HEATING INPUT TEMPERATURE AFUE STEADY STATE MOREL (Btuh) Y SEASONAL (Btuh) RISE(°F) (%) EFFICIENCY(%) EFFICIENCY(%) DJE004 74,000 58,460 25-55 76 80 73 3 DJD005 74,000 58,460 25-55 76 80 73 3 DJE005 115,000 90,850 35-65 76 80 741 DJD006 74,000 58,460 25-55 76 80 73 3 DJE006 115,000 90,850 35-65 76 80 741 DJ0007 74,000 58,460 25-55 76 80 73 3 DJE007 115,000 90,850 35-65 76 80 74 1 UNIT HEATING INPUT OUTPUT CAPACITY TEMPERATURE AFUE STEADY STATE CALIFORNIA SEASONAL MODEL (Btuh) (Btuh) RISE °F 48 First Stage/Second Stage First Stage/Second Stage ( ) (%) EFFICIENCY(%) EFFICIENCY(%) DJDO08 120,000 96,000 20-50 78 5 80 75.3 DJE008 120,000/180,000 94,800/142,200 35-65 78 5 80 76.5 DJDO09 120,000 96,000 20-50 78 5 80 75 3 DJE009 120,000/180,000 94,800/142,200 35-65 78 5 80 76 5 DJD012 120,000/180,000 94,800/142,200 35-65 78 5 80 76 5 DJE012 180,000/220,000 142,200/173,800 35-65 78 5 80 76 3 DJD014 180,000/220,000 142,200/173,800 35-65 78 5 80 76 3 LEGEND AFUE — Annual Fuel Utilization Efficiency w NOTE NO Levels are 40 nanogramsfjoule with accessory kit. (11) `� 11110 3 yr -a ----..swo Physical data BASE UNIT 48 DJE004 DJD/DJE005 DJD/DJE006 DJD/DJE007 NOMINAL CAPACITY 3 4 6 6 OPERATING WEIGHT(Ib) Unit 564 574 594 619 With Economizer 564 574 594 649 Roof Curb 115 115 115 115 COMPRESSOR Hermetic Quantity55 I 55 I 70 I 70 Oil(oz) REFRIGERANT TYPE R-22 Operating Charge(lb-oz) 3-13 I 5-8 I 6-11 I9-0 CONDENSER FAN Propeller Ouantity...Dlemeter(In.) 1...28 1 .26 1..26 1 .26 Nominal Cfm 3500 4100 4100 3800 Motor Hp...Rpm '/. 850 1 850 1/2 850 Y3 850 CONDENSER COIL Enhanced Copper Tubes,Aluminum Lanced Fin Rows...Fins/in. 1...17 1 .17 1...17 2..17 Total Face.Area(sq ft) 7.78 12 25 12.25 12 25 EVAPORATOR FAN Centrifugal Size(in.) 10x10 10x10 10x10 10x10 Type Drive Std Direct Direct Direct Belt Alt Direct Belt Belt Belt Nominal Cfm 1200 1800 2000 2400 Horsepower per National Std rh '/z 3/4 1 0 Electrical Code(NEC)' Alt Vz 3/4 1.0 1.5 Maximum Continuous Bhp Std 38 B7 1 29 1 70 Alt 78 1.30 1.70 2.40 Motor Frame Std 48 48 48 56 Alt 48 56 58 56 Nominal Rpm High/Low Std 860/845 1080/970 1080/1040 — Alt 1080/970 — — — Fan Rpm Range Std — — — 875-1190 Alt — 800.1130 875-1190 1070-1460 Motor Bearing Type Ball Ball Ball Ball Maximum Fan Rpm 2100 2100 2100 2100 Motor Pulley Pitch Diameter Std — — — 2.8-3.8 A/B(in.) Alt — 2 4-3 4 2 8-3 8 2.8-3.8 Fan Pulley Pitch Diameter(In.) Std — — — 5 5 AR — 52 55 45 Belt—Type...Length(In.) Std — — — A 40 Alt — A 40 A 40 A..39 Pulley Center Line Distance(In.) Std — — — 14 7-15.5 Alt — 14 7-15.5 14 7-15.5 14 7-15 5 • Speed Change Per Full Turn of Std — — — 63 Movable Pulley Flange(rpm) Alt — 66 63 79 Movable Pulley Maximum Full Std — — — 5 Turns from Closed Position Alt — 5 5 5 Factory Setting—Full Turns Open Std — — — 3 III • Alt — 3 3 3 Factory Speed Setting(rpm) Std — — — 1000 Alt — 930 1000 1230 Fan Shaft Diameter at Pulley(in.) — s/e s/a Vs EVAPORATOR COIL Enhanced Copper Tubes,Aluminum Double Wavy Fin Rows...Fins/In. 2. 15 2...15 3..15 4..15 Total Face Area(sq ft) 4 17 5.5 5 5 5 5 FURNACE SECTION Burner Orifice Diameter(in. ...drill size)t Natural Gas—Std 113...33 .113 33 113...33 113..33 Liquid Propane—Alt 089..43 089 43 089..43 089 43 Thermostat Heat Anticipator Setting(amps) 208/230/460 v 1.0 1 0 1 0 1 0 Gas Input 74,000 74,000/115,000 74,000/115,000 74,000/115,000 Efficiency(Steady State)(%) 80 80 80 80 Temperature Rise Range 25-55 25-55/35-65 25-55/35-65 25-55/35-65 Manifold Pressure(in.wg) Natural Gas—Std 35 35 3.5 35 Liquid Propane—Alt 3.5 3.5 3.5 3.5 Maximum Static Pressure(in.wg) 75 75 75 75 Field Gas Connection Size(In.) 5 : 5 5 5 HIGH-PRESSURE SWITCH(psig) Cutout 428 Reset(Auto.) 320 LOSS-OF-CHARGE/LOW-PRESSURE SWITCH (Liquid Line)(psig) Cutout 7± 3 Reset(Auto.) 22 ± 5 OUTSIDE-AIR INLET SCREENS Cleanable Quantity...Size(In.) 1...20 x 24 x 1 RETURN-AIR FILTERS Disposable Quantity...Size(In.) 2 16 x 25 x 2 LEGEND Bhp—Brake Horsepower _ 'Used to determine wire sizing per NEC t48DJD005.007 and 48DJE004(74,000 Btuh)units have 2 burners .rl� 48DJE005-007(115,000 Btuh)units have 3 burners. IL 4 Jun, 0 2020 BUILDING DIVISION RECEIVED CITY OF TIGAR uiJe3 a 6 I , boc) 4 • Id , > ellI k ) 1 . J 74 i i 4 1 . x 111 i w t •t 1 4 . A. i T w-. .nF '` . fie • syF • ww y • 111141 s ;♦ It _ , - .... _ "_ 4.- ' I '► k.. dew�nat�o1uogduosapeawM p�.a.� ii deW PallRun CITY OF TIGARD Approved lanning Date: -..2.. Initials: _____I---g • -