Loading...
Report (2) ; lPz020--00 P4ff /'/S J,�/r/ WALL SIGN DESIGN / ?727 C/ C G7 -i Scope of work is for the design of the connection of the wall sign to the existing structure only. See following pages for structural notes. ASCE 7-16-Components and Cladding Wind Speed,V= 98 mph Risk Category= II Exposure Category= B Sign Height= 20.00 ft(max) Topo.Factor,Kzt= 1.00 Direct.Factor,Kd= 0.85 Corner Zone: No Resulting Parameters and Coeffidents: Wall External Pressure Coeffdents,GCp: GCp Zone 4 Pos.= 0.90 GCp Zone 5 Pos.= 0.90 GCp Zone 4 Neg.= -0.99 GCp Zone 5 Neg._ -1.26 a= 7.00 \� G� PROP zg= 1200 Kh= 0.70 iN qh= 8.8 psf =0.00256"0.71`0.85`98"2'(0.6,allowable) [4 F Case 1,F(-)= -9.6 psf =(-0.99)1.8psf 725 ,PE Case 2,F(+)= 7.9 psf =(0.9)11.8psf • Sign Geometry: Height= 1.50 ft(total) 4�!; '—ON o Width= 14.33 ft(max) `(/� 0 %solid area= 60% 9,P1 /fy 08 Area= 12.9 ft2 =1.5'14.33'60% Sign Thickness= 5.00 in(channel letters or cabinet) `c ✓05EPH MP� Wi Sign Dead Load= 4.00 psf(max) Appx.Weight= 52 lb =4psf 12.9 EXPIRES:12-31-2020 Vertical offset= 0.00 in(positive#denotes centroid of sign above centroid of connection) Raceway Behind Channel Letters Raceway Height= 8.00 in Raceway thickness= 5.00 in fastener couple= 8.00 in(vertical) Total#of fasteners= 8 (minimum) 50% of fasteners resisting tension due to eccentricities V,fastener= 7 lb =52/(8 fasteners) M,case 1= -390 in-lb =-9.6*12.9`0"-52'(5"/2+5") T,case 1= 28 lb =390/8"/(8 fasteners`50%)+9.6'12.9ft'/(8)(Upper fasteners in tension) M,case 2= -390 in-lb =7.9'12.9'0"-5215"/2+5") T,case 2= 0 lb =390/8"/(8 fasteners`50%)-7.9`12.9fW(8)(Upper fasteners in tension) finish thickness= 0.00 in(non-structural) o.d.of pipe spacer= 0.00 in add!tension= 0 lb T,fastener= 28 lb V,fastener 7 lb Wall Const.: Concrete Fastener Type:Dewalt Power-Stud+SD1 Fastener Size: 0.375 in Tc= 610 lb>28 OK5% Vc= 580 lb>70K1% 0.06<1.00 OK Use 0.375"Dewalt Power-Stud+SD1 fasteners to Concrete 3/8"dia. DeWalt Power-Stud+SD1 with 2 1/2" min. embed into concrete, Typical at (8)approximate locations shown i 14'-4" • ►� JJ int Rovente Pizzeria Raceway Connection 200597 MILLER Project Name Project# q CONSULTING Location 13727 SW Pacific Hwy,Tigard, OR ENGINEERS • Client Hannah Sign Systems • 9600 SW Oak St#400 503.246.1250 CJM CPS- 6/4/2020 1 °13 Portland,OR 97223 mlllarae.com By Ck'd Date Page GENERAL THE CONTRACTOR IS RESPONSIBLE FOR VERIFICATION AND CORRELATION OF ALL ITEMS AND WORK NECESSARY FOR COMPLETION OF THE PROJECT AS INDICATED BY THE CONTRACT DOCUMENTS. SHOULD ANY QUESTION ARISE REGARDING THE CONTRACT DOCUMENTS OR SITE CONDITIONS, THE CONTRACTOR SHALL REQUEST INTERPRETATION AND CLARIFICATION FROM THE ENGINEER BEFORE BEGINNING THE PROJECT. THE ABSENCE OF SUCH REQUEST SHALL SIGNIFY THAT THE CONTRACTOR HAS REVIEWED AND FAMILIARIZED HIMSELF WITH ALL ASPECTS OF THE PROJECT AND HAS COMPLETE COMPREHENSION THEREOF. THE CONTRACTOR SHALL BE RESPONSIBLE FOR CONFORMANCE TO ALL SAFETY REGULATIONS DURING CONSTRUCTION. THE CONTRACT DRAWINGS AND SPECIFICATIONS REPRESENT THE FINISHED STRUCTURE. UNLESS OTHERWISE SPECIFICALLY NOTED, THEY DO NOT INDICATE THE METHOD OF CONSTRUCTION OR CONSTRUCTION LOADS. ONLY THE CONTRACTOR SHALL PROVIDE ALL METHODS, DIRECTION AND RELATED EQUIPMENT NECESSARY TO PROTECT THE STRUCTURE, WORKMEN AND OTHER PERSONS AND PROPERTY DURING CONSTRUCTION. THE CONTRACTOR SHALL, AT HIS OWN EXPENSE, ENGAGE PROPERLY QUALIFIED PERSONS TO DETERMINE WHERE AND HOW TEMPORARY PRECAUTIONARY MEASURES SHALL BE USED AND INSPECT SAME IN THE FIELD. ANY MATERIAL NOT AS SPECIFIED OR IMPROPER MATERIAL INSTALLATION OR WORKMANSHIP SHALL BE REMOVED AND REPLACED WITH SPECIFIED MATERIAL IN A WORKMANLIKE MANNER AT THE CONTRACTOR'S EXPENSE. THESE PLANS, SPECIFICATIONS, ENGINEERING AND DESIGN WORK ARE INTENDED SOLELY FOR THE PROJECT SPECIFIED HEREIN. MILLER CONSULTING ENGINEERS DISCLAIMS ALL LIABILITY IF THESE PLANS AND SPECIFICATIONS OR THE DESIGN, ADVICE AND INSTRUCTIONS ATTENDANT THERETO ARE USED ON ANY PROJECT OR AT ANY LOCATION OTHER THAN THE PROJECT AND LOCATION SPECIFIED HEREIN. OBSERVATION VISITS TO THE JOB SITE AND SPECIAL INSPECTIONS ARE NOT PART OF THE STRUCTURAL ENGINEER'S RESPONSIBILITY UNLESS THE CONTRACT DOCUMENTS SPECIFY OTHERWISE. • NON STRUCTURAL PORTIONS OF PROJECT, INCLUDING BUT NOT LIMITED TO PLUMBING, FIRE PROTECTION, LAND USE, SITE PLANNING, EROSION CONTROL, ELECTRICAL, MECHANICAL, FLASHING AND WATER-PROOFING ARE BEYOND THE SCOPE OF THESE DRAWINGS AND ARE PROVIDED BY OTHERS. EXISTING STRUCTURAL ELEMENTS ARE DESIGNED BY OTHERS. IN ACCORDANCE WITH SECTION 1704.2 EXECPTION 1, NO SPECIAL INSPECTIONS ARE REQUIRED FOR POST- INSTALLED ANCHORS AS THE LOADING IS A MINOR FRACTION OF THE CAPACITY OF THESE ELEMENTS. CONTRACTOR TO VERIFY ALL CONDITIONS PRIOR TO FABRICATION OR INSTALLATION. ENGINEER OF RECORD FOR THE PROJECT IS TO BE NOTIFIED IF CONDITIONS DIFFER FROM WHAT IS SHOWN ON THE DRAWINGS. BUILDING CODE ALL PHASES OF THE WORK SHALL CONFORM TO THE 2019 OREGON STRUCTURAL SPECIALTY CODE, BASED ON THE 2018 INTERNATIONAL BUILDING CODE, INCLUDING ALL REFERENCE STANDARDS, UNLESS NOTED OTHERWISE. 4.�•••., G PRE/0 4/ 725 /PE1' ilia Yr-ON 9 ti� 2 !RV 08 , ✓OSEPH ON• EXPIRES:12-31-2020 1 Project Name Rovente Pizzeria Raceway Connection Project# 200597 t MILLER E ENGINEEERSRS Location 13727 SW Pacific Hwy,Tigard, OR ENGIN Client Hannah Sign Systems 9800 SW Oak St#400 603,248.1250 L 2 of 3 Portland,OR 97223 mIller-ae,com By CJM Ck'd P5 Date 6/4/2020 Page DESIGN LOADS THE FOLLOWING ARE THE DESIGN REQUIREMENTS: STRUCTURAL DESIGN CRITERIA RISK CATEGORY II WIND DESIGN DATA BASIC WIND SPEED(3 SEC GUST) 98 MPH EXPOSURE B POST-INSTALLED ANCHORS ANCHORAGE • ANCHORS SHALL BE AS SPECIFIED ON THE DRAWINGS. ANCHORS SHALL BE INSTALLED IN CONFORMANCE WITH THE MANUFACTURERS INSTALLATION CRITERIA AND PER THE CURRENT ICC EVALUATION REPORT FOR THE ANCHOR.ANCHORS ARE NOT TO CUT THROUGH ANY EXISTING STEEL REINFORCING. ALUMINUM ALL STRUCTURAL ALUMINUM SHAPES AND PLATES TO BE 6061-T6. ALL WELDS TO USE 4043 ALUMINUM FILLER ALLOY. A PROTECTIVE BARRIER SHALL BE PROVIDED BETWEEN ALL STEEL AND ALUMINUM TO PREVENT CORROSION. ALL WELDING TO CONFORM TO AMERICAN WELDING SOCIETY(AWS)D1.2.WELD LENGTHS SHOWN ARE EFFECTIVE AS SPECIFIED PER THE ALUMINUM DESIGN MANUAL. WELDING SHALL BE BY AWS CERTIFIED WELDERS FOR WELD TYPES SPECIFIED. WHERE WELD LENGTHS ARE NOT SHOWN, THE WELD SHALL BE FULL LENGTH OF MEMBERS BEING JOINED. ALL BUTT WELDS SHALL BE FULL PENETRATION WELDS UNLESS NOTED OTHERWISE ON STRUCTURAL DRAWINGS. ALL WELDS TO RECEIVE THE SAME FINISH COAT AS THE MEMBER BEING WELDED. ALL FASTENERS IN CONTACT WITH ALUMINUM TO BE HOT DIPPED GALVANIZED WITH MATCHING NUTS OR HAVE A PROTECTIVE BARRIER TO PREVENT CORROSION. NUTS SHALL BE TIGHTENED TO A SNUG TIGHT CONDITION. � 14c, PROFFss�o � 725 ,PEA ilsa , 'ftE.ON o ti ti� Q os • gyp@ ✓OSEPN ta• EXPIRES: 12-31-2020 Project Name __ Rovente Pizzeria Raceway Connection Project# 200597 AI MILLER CONSULTING Location 13727 SW Pacific Hwy,Tigard, OR ENGINEERS . Client Hannah Sign Systems 9800 SW Oak St 0400 503.248.1250 ,I L P� 6/4/2020 3 of 3 Portland,OR 97223 miller-scow By Ck'd Date Page