Loading...
Permit FOR OFFICE USE ONLY—SITE ADDRESS: 1 1 15 l"'u"t"/ °if Cre4 This form is recognized by most building departments in the Tri-County area for transmitting information. Please complete this form when submitting information for plan review responses and revisions. This form and the information it provides helps the review process and response to your project. 111111 City of Tigard • COMMUNITY DEVELOPMENT DEPARTMENT Transmittal Letter TIGARD 13125 SW Hall Blvd. • Tigard, Oregon 97223 • 503.718.2439 • www.tigard-or.gov TO: Planning/building DATE RECEIVED: • DEPT: BUILDING DIVISION RECEIVED FROM: Mary Dinsmore-Smith JUL 1 1 2023 COMPANY: TML International LLC dba Infinity Solar CITY OF'TIGAfID PHONE: 360-326-0650 BUILDING DIVI leki EMAIL: permit@infinitysolarusa.com RE: 11935 SW Summer Crest Dr MST2023-00265(REV 2) (Site Address) (Permit Number) Solar I nstal I-KBBul lock (Project name or subdivision name and lot number) ATTACHED ARE THE FOLLOWING ITEMS: Copies: Description: Copies: Description: Additional set(s) of plans. 1 Revisions: Revised plan set Cross section(s) and details. Wall bracing and/or lateral analysis. Floor/roof framing. Basement and retaining walls. Beam calculations. Engineer's calculations. Other(explain): REMARKS: Changes are on sheet E 1.1 with electrical changes:Meter/main combo unit added,main panel rating/breaker size change. FO OFF E USE ONLY M Routed to Permit Technic' n: Date: 1 Initials: Fees Due: El Yes No Fee Descr' tion. Amount Due: i`j c i'l 6-1-- s 0- Special Instructions: Reprint Permit(per P ): ❑ Yes / No IDDonc Applicant Notified: / A4p) Date: 7 7 ?-3 Initials: . 1:\Building\Forms\Transm ittalLetter-Revisions_073120.doc . • PHOTOVOLTAIC ROOF MOUNT SYSTEM 0 16 MODULES-ROOF MOUNTED - 6.480 kW DC, 6.144 kW AC, 11935 SW SUMMER CREST DR, TIGARD, OR 97223 infinity solar INFINITY HOME SOLUTIONS PHOTOVOLTAIC SYSTEM SPECIFICATIONS: SITE DETAIL: SHEET INDEX: 64 MILL PLAIN VANCOUVER WA 98661 SYSTEM SIZE: 6.480 KW DC UTILITY: PORTLAND GENERAL ELECTRIC PV 0.0: GENERAL NOTES AND PROJECT DATA DS 07: WIRING SPECIFICATION PHONE:1-800-818-0598 6.144 KW AC MSP: NEW 200A WITH 200A MAIN BREAKER PV 1.0: PLOT PLAN DS 08: MOUNTING-DATA SHEET INFINITY SOLAR.COM MODULE TYPE&AMOUNT: (16)ZNSHINESOLAR ZXM7-SH108-405M ROOF MATERIAL: COMPOSITE SHINGLE PV 1.1: SITE PLAN DS 09: RACKING-DATA SHEET MODULE DIMENSIONS: (UWIH)67.87"144.64"11.18" ASCE 7-10 WINDSPEEDS: (3 SEC GUST IN MPH) PV 1.2: ROOF SECTION DS 10: RACKING-GROUNDING ' , 1 REVISIONS INVERTER: (08)AP SYSTEMS DS3-L RISK CATERGORY I: 100 IM 1.0: INVERTER MAP DS 11: RACKING-CERTIFICATION ( Decoction Date Nov INTERCONNECTION METHOD: SUPPLY BREAKER RISK CATEGORY II: 110 S 1.1: MOUNT DETAILS v����0Z AHJ: CITY OF TIGARD RISK CATEGORY III-IV: 115 E 1.1: 3-LINE DIAGRAM RACKING: GRASOL RACKING SYSTEM FOR COMP ROOF E 1.2: NOTES GOVERNING CODES: ARRAY AREA: 21.04 SOFT x 16=336.6 SOFT E 1.3: WARNING LABELS 05 01: PV MODULE SPECIFICATION SHEET D 2010 OREGON SOLAR INSTALLATION SPECIALTY CODE LIABILITY DS 02: MICROINVERTER SPECIFICATION SHEET 2022 OREGON STRUCTURAL SPECIALTY CODE(OSSC) The City of Tigard and its DS 03: COMBINER PANEL CERTIFICATION ' 2021 OREGON ELECTRICAL SPECIALTY CODE(NEC 2020) e" npL yee"; shall not be DS 04: AC DISCONNECT UL CERTIFICATION JUL 1 1 2023 2022 OREGON FIRE CODE reSpen .Ve for discrepancies DS 05: AC DISCONNECT UL CERTIFICATION :, xr DS 06: JUNCTION BOX UL CERTIFICATION which may appear herein. f CITY OF TI AP, I PHOTOVOLTAIC NOTES: �Uil# If�9VISI�N 1.AN INVERTER OR AN AC MODULE IN AN INTERACTIVE PHOTOVOLTAIC SYSTEM SHALL AUTOMATIC ALL WITH THE"SMACNA"-GUIDLINES FOR SEISMIC RESTRAINS OF MECHANICAL SYSTEMS AND PLUMING PIPING , ` '` `,.. � Address DE-ENERGIZE ITS OUTPUT TO THE CONNECTED ELECTRICAL PRODUCTION AND DISTRIBUTION NETWORK SYSTEMS. a , + UPON LOSS OF VOLTAGE IN THAT SYSTEM AND SHALL REMAIN IN THAT STATE UNTIL THE ELECTRICAL 22.ALL OF THE LISTED SYSTEMS REQUIRED THAT THE SEISMIC LATERAL FORCE F INCLUDING )r W PRODUCTION AND DISTRIBUTION NETWORK VOLTAGE HAS BEEN RESTORED.(NEC 690361) CONSIDERATION OF a"P AND r"P BE DETERMINED AT EACH LEVEL OF THE BUILDING SO THAT BRACE ) 4` w 2.ALL EXTERIOR ELECTRICAL METALLIC TUBING(EMT)CONDUIT FITTING SHALL BE RAIN TIGHT SPACING CAN BE CALCULATED.THE DISTRICT STRUCTURAL ENGINEER CAN APPROVE THE SEISMIC .0:, •THREAD-LESS COMPRESSION TYPE. LATERAL FORCE DETERMINATION. ,L a 3.MODULES AND SUPPORT STRUCTURES SHALL BE GROUNDED 23.A COPY OF THE CHOSEN BRACING SYSTEM(S)INSTALLATION GUIDE/MANUAL SHALL BE ON THE JOB e,., 9 f (1) E 4.NAMEPLATES SHALL BE PROVIDED FOR ALL CIRCUITS IN THE SERVICE DISTRIBUTION AND POWER SITE PRIOR TO STARTING THE INSTALLING OF HANGERS AND/OR BRACES. Approved plans '=I `, w p 8 DISTRIBUTION SWITCH BOARDS,PANEL BOARDS,DISCONNECTING SWITCHES,TERMINAL CABINETS, 24.WHEN INSTALLING DRILLED-IN ANCHORS AND/OR POWDER DRIVEN PINS IN EXISTING Y F- Qi Le ETC shall be on job site. �. ` ;� ETC. ALL NAMEPLATES SHALL BE PERMANENTLY ATTACHED AND BE OF SUFFICIENT CAPACITY TO NONERESTRESSED REINFORCED CONCRETE,USE CARE AND CAUTION TO AVOID CUTTING OR ram` - 0 W N co E WITHSTAND THE WEATHER. DAMAGING THE REINFORCED BARS.WHEN INSTALLING THEM INTO EXISTING PRE-STRESSED CONCRETE L' - O c.I 5.JUNCTION BOX/COMBINER BOX HAVE TO USE COMPRESSION TYPE STRAIN RELIEF POSITIONED FOR TENDONS BY USING A NON-DESTRUCTIVE METHOD PRIOR TO INSTALLATION.EXERCISE EXTREME CARE ` _1 ix rn r, c, APPROPRIATE WATER RUN OFF. AND CAUTION TO AVOID CUTTING OR DAMAGING THE TENDONS DURING INSTALLATION.MAINTAIN A r W Il' 6.CONDUIT RUNS SHALL BE PROVIDED WITH SUFFICIENT WEATHERPROOF PULL BOXES OF JUNCTION MINIMUM CLEARANCE OF ONE INCH BETWEEN THE REINFORCEMENT AND THE DRILLED-IN ANCHOR. In O o VALIDITY OF �' ' CC _ , s BOX/COMBINER BOXES PER APPROPRIATE NEC REQUIREMENTS. 25.THE WORKING CLEARANCES AROUND THE EXISTING ELECTRICAL EQUIPMENT AS WELL AS THE NEW g " ~ uj p 7.SEE PROVIDED CUT SHEETS FOR ADDITIONAL EQUIPMENT SPECIFICATIONS ELECTRICAL EQUIPMENT WILL BE MAINTAINED IN ACCORDANCE WITH NEC 110.26. - "� W CO Q ill 8.WIRING MATERIALS SHALL BE SUITABLE FOR THE SUN EXPOSURE AND WET LOCATIONS.FIELD 26.CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS SUNLIGHT RESISTANT.(NEC 300.6 01,310.8 D) : . THE ISSUANCE OF A PERMIT m0 0z APPLIED PROTECTIVE COATINGS ARE NOT ACCEPTABLE. 27.GROUNDING BUSHINGS ARE REQUIRED AROUND PRE-PUNCHED CONCENTRIC KNOCKOUTS ON THE BASED ON CONSTRUCTION 2 SATELLITE VIEW O I- 0 9.JUNCTION,PULL AND OUTLET BOXES LOCATED BEHIND MODULES SHALL BE SO INSTALLED THAT THE DC SIDE OF THE SYSTEM.(NEC 250.97) DOCUMENTS AND OTHER J Pv a a SCALE:NTS `� rn d WIRING CONTAINED IN THEM CAN BE RENDERED ACCESSIBLE DIRECTLY OR BY DISPLACEMENT OF 28.THE GROUNDING ELECTRODE CONDUCTOR MUST BE PROTECTED FROM PHYSICAL DAMAGE IF DATA SHALL NOT PREVENT - W MODULE(S)SECURED BY REMOVABLE FASTENERS AND CONNECTED BY A FLEXIBLE WIRING SYSTEM.(NEC 690.34) SMALLER THAN#6 COPPER WIRE.(NEC 250.64 B) I- W 10.IN AN UNDERGROUND PHOTOVOLTAIC SYSTEM,THE POWER SOURCE SHALL BE LABELED WITH THE 29.GROUNDING ELECTRODE CONDUCTOR WILL BE CONTINUOUS,EXCEPT FOR SPLICES OR JOINTS AT THE CODE OFFICIAL FROM ,, - co FOLLOWING WARNING AT EACH JUNCTION BOX,COMBINER BOX,DISCONNECT AND DEVICE WHERE THE BUSBARS WITHIN LISTED EQUIPMENT.(NEC 250.64 C) REQUIRING THE CORRECT.'ONt r''" ''' Ct - Ct UNGROUNDED CIRCUITS MAY BE EXPOSED DURING SERVICE:"WARNING-ELECTRIC SHOCK HAZARD. 30.RACEWAY FOR GROUNDING ELECTRODE CONDUCTOR SHALL BE BONDED AT EACH END.(CEC 250.64(E) OF ERRORS. ORSC THE CURRENT CIRCUIT CONDUCTORS OF THIS PHOTOVOLTAIC POWER SYSTEM ARE UNGROUNDED BUT 31.WHERE ALL TERMINALS OF THE DISCONNECTING MEANS MAY BE ENERGIZED IN THE OPEN POSITION, 1 " ,' a ' rt,. ,,�. z,,'Y - F Garden MAY BE ENERGIZED WITH THE RESPECT TO GROUND DUE TO LEAKAGE PATHS AND/OR GROUND(NECE 690.35(F)) A SIGN WILL BE PROVIDED WARNING OF THE HAZARD PER NEC 690.17.34.EACH UNGROUNDED ,,,, r '4' Hom'e"'whhtord :- 11.ALL PHOTOVOLTAIC MODULES AND ASSOCIATED EQUIPMENT AND WIRING MATERIAL SHALL BE PROTECTED CONDUCTOR OF THE MULT-MIRE BRANCH CIRCUIT WILL BE IDENTIFIED PER PHASE AND SYSTEM PER '" %��n Sheet Name FROM ANY PHYSICAL DAMAGE. NEC210.5. 9 ., �� _, GENERAL NOTES 12.ALL ELECTRICAL DEVICES AND UTILIZATION EQUIPMENT SHALL BE LISTED BY AN APPROVED TESTING AGENCY. 32.CIRCUITS OVER 250V TO GROUND SHALL COMPLY WITH NEC250.97&250.92(8)&LAMC 93.250.97. OFFICE COPY, ren AND PROJECT 1 13.OUTDOOR EQUIPMENT SHALL BE AT LEAST NEMA 3R RATED. 33.DC CONDUCTORS EITHER DO NOT ENTER THE BUILDING OR ARE RUN IN METALLIC RACEWAYS OR 40T4 DATA ,LAMC 93.690.31 ( ) lEi 14.ALL SPECIFIED WIRING IS BASED ON THE USE OF COPPER ENCLOSURES TO THE FIRST ACCESSIBLE DC DISCONNECTING MEANS PER NEC 690.31 E ear_a au -_ Metzger 15.CONTRACTOR SHALL OBTAIN ELECTRICAL PERMITS AND SHALL COORDINATE ALL INSPECTION, 34.ALL METALLIC FRAME RAILS AND OTHER CURRENT CARRYING METALLIC COMPONENTS(CONDUIT, a:->;c,9 I " Sheet Size COMMISSIONING AND ACCEPTANCE WITH THE CLIENT,UTILITY CO.AND CITY INSPECTORS AS NEEDED JUNCTION&PULL BOXES,RACEWAY,ETC)SHALL BE SOLIDLY GROUNDED PER THE MANUFACTURERS CITY OF TIGARD- �"ea 16.DRAWINGS ARE DIAGRAMMATIC ONLY,ROUTING OF RACEWAYS SHALL BE AT THE OPTION OF THE INSTALLATION INSTRUCTIONS LAMC 93.690.110.3&93.110.3(6). NCO- ANSI B CONTRACTOR UNLESS OTHERWISE NOTED AND SHALL BE COORDINATED WITH OTHER TRADES. 35.SCREWS,NUTS,BOLTS&WASHERS THAT ATTACH EQUIPMENT GROUNDING LUGS SHALL BE REVIEI 'ED FO ODE'COMPLIANT' C';,"B`.°" > >ak 9''9'"'rU°' 17.IF DISTANCES OF CABLE RUNS ARE DIFFERENT THAN SHOWN,THE CONTRACTOR SHALL NOTIFY STAINLESS STEEL LAMC 93.110.3(B). / u X 7n ELECTRICAL ENGINEER TO VALIDATE THE WIRE SIZE.FINAL DRAWINGS WILL BE RED-LINED AND UPDATED AS 36.NO PIPING,DUCTS OR EQUIPMENT FOREIGN TO ELECTRICAL EQUIPMENT SHALL BE PERMITTED TO BE APProcd: I✓✓] -, A . ,, `es i APPROPRIATE. LOCATED WITHIN THE DEDICATED SPACE ABOVE THE ELECTRICAL EQUIPMENT. OTC: _ . Sheet Number I find 18.WHENEVERA DISCREPANCY IN QUANTITY OF EQUIPMENT,ARISES ON THE DRAWINGS OR 37.ALL FIELD INSTALLED JUNCTION,PULL AND OUTLET BOXED LOCATED BEHIND MODULES OR PANELS � �n�.,_ 2� ^ a�9q ,, SPECIFICATIONS,THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING AND INSTALLING ALL SHALL BE ACCESSIBLE DIRECTLY OR BY DISPLACEMENT Of A MODULE(S)OR PANEL(S)SECURED BY Permit #: I, J I !�/ 1 OD/ S W `"�! t PV 0"0 MATERIAL AND SERVICES REQUIRED BY THE STRICTEST CONDITIONS NOTED ON THE DRAWINGS OR IN REMOVABLE FASTENERS. 2� e" THE SPECIFICATIONS TO ENDURE COMPLETE COMPLIANCE AND LONGEVITY OF THE OPERABLE SYSTEM 38.REMOVAL OF A DWP-INTERACTIVE INVERTER OR OTHER EQUIPMENT SHALL NOT DISCONNECT THE Address: 1,1I"� J/ /T �\�� REQUIRED BY THE ARCHITECT/ENGINEER. BONDING CONNECTION BETWEEN THE GROUNDING ELECTRODE CONDUCTOR AND THE PHOTOVOLTAIC U`' v 19.ALL BROCHURES,OPERATION MANUALS,CATALOGS,SHOP DRAWINGS,ETC.SHALL BE HANDED SOURCE AND/OR OUTPUT CIRCUIT GROUNDED CONDUCTOR. SEIttC #: • 0 OVER TO THE OWNER'S REPRESENTATIVE AT THE COMPLETION OR WORK. 39.THE ROOF MOUNTED PHOTOVOLTAIC MODULES,PANELS,OR SOLAR VOLTAIC ROLL ROOFING By. PIA Dates 7�7i�'�, 20.ALL WIRING CONCEALED IN WALL AND CEILING SPACES SHALL BE IN METAL CONDUIT. MATERIAL SHALL HAVE THE SAME OR BETTER LISTED FIRE-RESISTANCE RATING THAN THE BUILDING LL1111 21.THE SEISMIC BRACING AND ANCHORAGE OF ELECTRICAL CONDUITS SHALL BE IN ACCORDANCE ROOF-COVERING MATERIAL.rTh GENERAL NOTES AND PROJECT DATA 40.ALL ROOF MOUNTED CONDUIT WILL BE A MINIMUM 1/7 OFF THE ROOF SURFACE. // 3-. VICINITY MAP avoo \ Pva.a % SCALE:NTS PHOTOVOLTAIC ROOF MOUNT SYSTEM6(1 16 MODULES-ROOF MOUNTED - 6.480 kW DC, 6.144 kW AC, 11935 SW SUMMER CREST DR, TIGARD, OR 97223 infinity INFINITY HOME SOLUTIONS A ROOF ACCESS POINT e405 E MILL PLAIN PHOTOVOLTAIC SYSTEM SPECIFICATIONS: /�� • PHONE.VERWA98661 / O,� ROOF ACCESS POINT SHALL NOT BE LOCATED IN AREAS PHONE.1-6aa616-050e SYSTEM SIZE: 6.480 kW DC F' 6.144 kW AC �� THAT REQUIRE THE PLACEMENT OF GROUND LADDERS INFINITY SOLAR.COM \(. OVER OPENINGS SUCH AS WINDOWS OR DOORS,AND MODULE TYPE&AMOUNT: (16)ZNSHINESOLAR ZXM7-SH108-405M / (s LOCATED AT STRONG POINTS OF BUILDING REVISIONS MODULE DIMENSIONS: (UW/H)67.87"144.64'/1.18" CONSTRUCTION IN LOCATIONS WHERE THE ACCESS / Descripton Dale Rev INVERTER: (08)AP SYSTEMS DS3-L _, \_ POINT DOES NOT CONFLICT WITH OVERHEAD AHJ: CITY OF TIGARD J OBSTRUCTIONS SUCH AS TREE LIMBS,WIRES OR SIGNS00 Z. v / j; ; i� --)----...\_ TREE TYP. SignaNrewitltSeal N 1�. % J� \\ / ;' \ 'a's Project Name& Address ��� ' /) W „oQ o Q J \\ o 0 U\� U co co (0 E \ 0 tr N U _I UI— \ ds \ ROOF ACCESS POINT m I w ce rn \\ \ Ca. CA Q W 75 N. CC uo �\ \ \ W FENCE \\ \ G� \ <'o- \ FL 12- \ \, ‘ ))- 14 ��Py \ 6, 10,0 ^ pW- \ �v' Sheet Name ' \ / \ ,99- PLOT PLAN NEW EXTERIOR MAIN SERVICE � , — � \ ./ PANEL TIED TO EXTERIOR \ \ i Sheet Size UTILITY METER#24 540 890 \ \ / ANSI B \ ' O 11" X 17" o ROOF#1 " Sheet Number (16)ZNSHINESOLAR ZXM7-SH108-405M �\ J4' 'cL SLOPE 22° \ �5� 6s*) (l PV 1 ,0 \ A�\ / p�rj�� NEW PV AC DISCONNECT VISIBLE, 1 PLOT PLAN ,-..t. ►�N LOCKABLE, LABELED DISCONNECT PV1.0 SCALE:5/64"=1'-0" y WITHIN 10' OF UTILITY METER F PHOTOVOLTAIC SYSTEM SPECIFICATIONS: SYSTEM LEGEND ^ SYSTEM SIZE: 6.480 KW DC NEW EXTERIOR MAIN SERVICE PANEL&POINT OF V 6.144 KW AC n INTERCONNECTION.TIED TO EXTERIOR UTILITY MODULE TYPE&AMOUNT: (16)ZNSHINESOLAR ZXM7-SH108-405M METER#24 540 690. Infinity SOiar MODULE DIMENSIONS: (LJW/H)67.87"/44.64"/1.18" INVERTER: (08)AP SYSTEMS DS3-L p[ NEW VISIBLE,LOCKABLE,LABELED DISCONNECT INFINITY HOME SOLUTIONS 1 "'1 LOCATED WITHIN 10'FROM THE UTILITY METER 6405EMILLPLAIN AHJ: CITY OF TIGARD O VANCOUVER WA 98661 PHONE 1-808-818-0598 VISIBLE, LOCKABLE, LABELED DISCONNECT p INFINITY SO AR.COM C NEW DEDICATED PV SYSTEM COMBINER PANEL. WITHIN 10'OF UTILITY METER REVISIONS p 16 NEW DISH INESOLARZXM7-SH108-405M MODULES DeariPt , Data Ray NOTE : WITH NEW(06)AP SYSTEMS DS3-L INVERTERS. ATTIC RUN-YES ATTIC FAN-NO j =FIRE PATHWAY SHUTDOWN-YES Signature with Seal N DO =ROOF OBSTRUCTIONS r77"::\0 N6� - y � '� • =ATTACHMENT POINTS 0 - v --- =RAFTER 7\, Project Name& O __-� \ \ Address O "� �� --- =RACKING SYSTEM W U ' ,•'' -- = ATTIC RUN WO p i ' Cn - �ti� - ,• joy'• =CONDUIT ATTIC RUN JUNCTION BOX p �� i ,' ?P14* C.) Lii co co EE`` /- • i O NN. V i z _, w rn rn r i ,Z' , W u7 v i� ; •- •' f'� �,' ' ocl`�o� 0. ROOF SECTIONS 0 ,o - o jr, 7'- •' X ,.' ROOFp01 MODULE-16 °� rn ¢ , .r ' A I CO 4" SLOPE-22' W O • �'/ • f ��� S� �v AZIMUTH-143° W • �, ' OJ . MATERIAL-COMPOSITE SHINGLE - ` <\> • „' - �'R x" J P'PGOG• A !.� RAFTER SIZE&SPACING-TX6"Q24'O.C. Y NEW EXTERIOR MAIN SERVICE PANEL& POINT OF INTERCONNECTION.TIED TO •- X 1 Q�PStx� ��O`` EXTERIOR UTI IJTY METER#24 540 890 O ; / GV� "� Sheet Name NEW PVAC DISCONNECT GROUPED .' MODULE, ARRAY WEIGHT (LOAD WITH SERVICE EQUIPMENT(VISIBLE, 2� SITE PLAN LOCKABLE,LABELED) A�J Number o CALLS) NEW AC COMBINER PANEL N Numbf Modules 16 Sheet Size Module Weight 45.19 LBS Total Module(Array)Weight 723.04 LBS ANSI B Number of Attachment point 50 11" X 17" BILL OF MATERIALS Mounting System Weight NUMBER OF MODULES 16 ZNSHINESOLARZXM7-SH108-405M (PerMod'de1 1.5 LBS Sheet Number NUMBER OF INVERTER 08 AP SYSTEMS DS3-L Mounting System Weight 75.00 LBS Total System Weight PV 1.1 NOTE:- EATON BR STYLE 1-INCH LOAD CENTER 798.04 LBS COMBINER PANEL 1 Was w«md System ROOF ATTACHMENTS SHALL BE SPACED NO - 816L125RP Weight at Each Attachment Point GREATER THAN 24 IN.OC IN ANY DIRECTION AC DISCONNECT 1 60A NON FUSIBLE AC DISCONNECT,240V w y „ ,,, At Attachment 14.46 LBS WHERE LOCATED WITHIN 3FT. OF A ROOF NUMBER OF ATTACHMENTS 50 GRASOL GS-10 RAIL ATTACHMENTS Module Area(67.87'x44.64') 21.04 SqFt EDGE,HIP, EAVE OR RIDGE(OSISC 305.4.3) CIRCUIT(S) RAILS 9 GRASOL RACKING SYSTEM Total Array Area 336.64 SqFt RAIL SPLICE 8 SPLICE KIT Distributed Load Y,22 Per SqFt /% _CIRCUIT#1 -08 MODULES WITH 04 MICROINVERTERS No CLAMPS 28 MID CLAMPS I UFO °""Sy"""w4910T "'°''""' 1.1 1 SITE PLAN END CLAMPS B END CLAMPS/STOPPER SLEEVE Total Roof Area 2131 SqFt �/////,//1 CIRCUIT#2-08 MODULES WITH 04 MICROINVERTERS Total Percentage or Roof Covered (DvSCALE:1/8"=1'-0" GROUNDING LUG 4 GROUNDING LUG Total Amy Me MINI Roofa �"a., 15.80% 0 infinity sob r • INFINITY HOME SOLUTIONS 6405 E MILL PLAIN VANCOUVER WA 98661 PHONE:1R00-818-0598 INFINITY SOLAR.COM REVISIONS 31_6Ir ''31-6". Description Hate Rev (N) PV MODULE ROOF _ _ `, -- H 2" X 6" RAFTER @ 24" O.C. . 1'-4 --:„1:., _,_.--„ Signature with Seal „ J ,,,,.:: LLJ t m 10'-0 % 10'-011 �`' 3'-2" 3'-2" - _ Fret dresse8 j U 3'-6" Z 0 22.00 22.0° CO 10 i—__. —__� ___._— U W N CD E 0 U a) a —Id- ' OD ro's co W � � m � � M� 12'-4" 12'-4 D m � CZ _o O CO H O co M aJ W .- g ROOF SECTION I- - W Y Sheet Name ROOF SECTION • EXTERIOR BEARING WALL EXTERIOR BEARING WALL\\,,. / Sheet Size ANSI B V\-- 11" X 17" Sheet Number PV 1.2 1 ROOF SECTION (PV1.2 0 N 1 13 infinity solar INFINITY HOME SOLUTIONS 6495E MILL PLAIN VANCOUVER INA 98661 41r — PHONE:1A00A180596 2 14 INFINITY SOLAR.COM REVISIONS Description Date Rev 3 15 Signature with Seal 4 16 Project Name& Address 5 17 w U z w 0_ C7 ce w O 6 18 ct Y c~!) L .R 0 Wco (' N 7 \�\ J ce W rn Q) N' 7 19 M � �o i c d J 8 20 w w ' C � EE / 9 21 Sheet Name \":ZY INVERTER MAP 1 0 22 Sheet Size ANSI B 11" X17" Sheet Number 11 23 I 1.0 12 24 1 ' INVERTER MAP DTU/ECU: \ IM 1.6 GENERAL STRUCTURAL NOTES: PV MODULE 0 1. THE SOLAR PANELS ARE TO BE MOUNTED TO THE ROOF FRAMING USING THE GRASOL RACKING SEE(2/S 1.1)FOR `` infinity so:1 SYSTEM WITH GRASOL GS-10 MOUNT ENLARGED VIEW ATTACHMENTS.THE MOUNTING FEET ARE TO BEINFINITYHOME SOLUTIONS IN SPACED AS SHOWN IN THE DETAILS, AND MUST 640W5 E MILL VANCOUVER WA 98661 BE STAGGERED TO ADJACENT FRAMING / % PHONE:1A80.818-0598 MEMBERS TO SPREAD OUT THE ADDITIONAL / /� INFlNITYSDLAR.COM LOAD. \ 2. UNLESS NOTED OTHERWISE, MOUNTING REVISIONS ANCHORS SHALL BE 114° LAG SCREWS WITH A / C'' s RS rA2Qe OC Desonptlon Date Rev MINIMUM OF 2-1/2" PENETRATION INTO ROOF „Rp FRAMING. ' X6 , 3. THE PROPOSED PV SYSTEM ADDS 2.5 PSF TO THE ' I ROOF FRAMING SYSTEM. / (E)COMPOSITE SHINGLE ROOF 4. ROOF LIVE LOAD=20 PSF TYPICAL,0 PSF UNDER Signature with Seal NEW PV SYSTEM. ` _ ...--- 1 5. GROUND SNOW LOAD=N/A PSF 6. WIND SPEED=110 MPH 7. EXPOSURE CATEGORY=C 8. RISK CATEGORY=II Project Name& Address uJ 0 �1� ATTACHMENT DETAIL (SIDE VIEW) 0 C ce s i. SCALE:NTS �' 0 0 w com E 0 Et FA . " r, —d ct Cn if O) SOLAR MODULE 0CI 0 o d in Y /' w Cn ¢ Li 0 0 z -a GRASOL GS-10 RAIL aLi w r' a 2 ' \ ( w t iY Sheet Name GS-FK-02 305MM ROOF FLASHING MOUNT DETAIL Sheet Size BUILDING STRUCTURE ANSI B 11" X 17" Sheet Number ROOF S 1.1 1/4"X 3" SS LAG SCREW 2.5" MIN. EMBEDMENT 12- ATTACHMENT DETAIL ENLARGED VIEW 5tt SCALE:NTS PV MODULE RATING @ STC MICROINVERTERS SPECIFICATION Rooftop conductor ampacities designed in compliance with THIS PANEL IS FED BY MULTIPLE SOURCES MANUFACTURER ZNSHINESOLAR ZXM7-SH108-405M MICROINVERTER MAKE AP SYSTEMS art. 690.8,Tables 310.15(B)(2)(a), 310.15(B)(3)(a), (UTILITY AND SOLAR) 0 MICROINVERTER MODEL NO. DS3-L 310.15 B 3 c , 310.15 B 16 , Chapter 9 Table 4,5, &9.MAX.POWER-POINT CURRENT(IMP) 13.03AMPS ( )( )O ( )( ) p 26A infinitysolar MAXIMUM AC OUTPUT 768 w AC OUTPUT CURRENT Location specific temperature obtained from ASHRAE 2017 MAX.POWER-POINT VOLTAGE(VMP) 31.10 VOLTS MAX INPUT VOLTAGE 60 V INFINITY HOME SOLUTIONS data tables NOMINAL AC VOLTAGE 240V 6405E MILL PLAIN OPEN-CIRCUIT VOLTAGE(VOC) 37.30 VOLTS MAX AC CURRENT 3.20 A VANCOUVER WA 98661 MAX OUTPUT VOLTAGE 240 V RECORD LOW TEMP -8°C ° PHONE:1-800-818-0598 SHORT-CIRCUIT CURRENT(ISC) 13.77 AMPS 120% RULE INFINITY SOLAR.COM NOM.MAX.POWER AT STC(PMAX) 405 WATT AMBIENT TEMP(HIGH TEMP 2%) 32°C VISIBLE, LOCKABLE, LABELED DISCONNECT BUS BAR RATING X 120%) - MAIN BREAKER RATING REVISIONS MAX.SYSTEM VOLTAGE 1500v WITHIN 10'OF UTILITY METER CONDUIT HEIGHT 0.5" = MAX. PV OCPD ° an Mee R,° VOC TEMPERATURE COEFFICIENT -0.29%/°C ROOF TOP TEMP 54°C MODULE: (16)ZNSHINESOLAR ZXM7-SH108-405M UPGRADE TO NEW 200A MAIN BUSS/W CONDUCTOR TEMPERATURE RATE 90°C (200A x 120%) 200 = 40A INVERTER: (08)AP SYSTEMS DS3-L NEW 200A MAIN BREAKER (3)#8 AWG THRN THWN-2 (1)#8 AWG THHN/THWN-2 EGO Signature with Seal NOTE : (NI NEMA 14-50 3/4"EMT CONDUIT ATTIC RUN-YES 240V PLUG SHUTDOWN-YES POINT OF INTERCONNECT,SUPPLY BREAKER Project Name& NEW 240V/200A BUS BAR RATING SOLAR Address READY MAIN SERVICE PANEL,SINGLE w PHASE,WITH A 200A MAIN DISCONNECT NEW INTERIOR 240VI200A U UTILITY COMPANY-PORTLAND SUB PANEL WITH A NEW ' w (16)ZNSHINESOLAR ZXM7-SH108-405M (N)BLADE TYPE GENERAL ELECTRIC 200A MAIN BREAKER , p 08 AP SYSTEMS DS3-L INVERTERS (N)125A COMBINER PANEL, NON FUSIBLE AC DISCONNECT UTILITY METER#24 540 890 cn re E ( ) 240V,3W,1-PHASE NEMA 3R 60A-2P 120/240VAC (N)PVC A 0 0o BRANCH 1-OS MODULES WITH 04 MICRO INVERTERS ' (VISIBLE,LOCKABLE,LABELED) BEAKER �T L1 _ r , U w N � E ::::: I L2 200A E�( �) ::::: :::::: : II::::: M • ::::: I ' � wcc � � (N)50A m o M 1 200A - 0 ' I- ? p o L_-�J L J L_= J L-__J (N)JUNCTION BOX o w Cr) Q LLj F may, .�, lv , 600 V,NEMA4 20A (E)LOADS m C7 Z (E)LOADS Cr) - Q t -L J 1 UL LISTED u — —0 xS c`i d -' 1 BRANCH 2-08 MODULES WITH 04 MICRO INVERTERS n L1 L1 20A I 4 (E)LOADS --0. , w _ g C I I- . w I u ' E. {2 L G I- a — G- I— 0 r I GI G G I 99gg I ` I F L. — J L_ _J L_ __J L--_-_J I "r`� J - --L- �nr J^...... N 4 _� _ .' Sheet Name t JJ I EXISTING GROUNDING 3-LINE r- L I L I O O O EXISTING GROUNDING_ L _cl__J ' ELECTRODE SYSTEM (3)#4/0 AWG Al ELECTRODE SYSTEM DIAGRAM (1)#6 AWG THWN-2 GND Sheet Size 11/2" M C• D T WIRE MAX PARALLEL C.0 PV CURR. TOTAL CONT. CURR WIRE TEMP CONDUIT WIRE DERATED MAX. CONT. LENGTH VOLTAGE ANSI B TAG# DEVICES RATING MULT CURR X 125% WIRE 51ZE1TYPEIAMP. OCP #C.C.C. CONDUIT DE-RATE: FILL: AMP: AMPACITY CURRENT GND FT. MAX DROP(%) 11" X 17" Sheet Number O 04 x 3.20 x N/A = 12.80A 16.00A #101 THWN 140A @90°C 20A 2 TRUNK IN AIR CABLE 0.96 x 1.00 x 40A 38.40A 12.80A #6 AWG 40 0.57 E " 1 O04 x 3.20 x N/A = 12.80A 16.00A #101 THWN 140A @90°C 20A 4 3/4" EMT 0.96 x 0.80 x 40A 30.72A 12.80A #8 AWG 50 0.52 1.27< 2 0 08 x 3.20 x N/A = 25.60A 32.00A #8 1 THWN 1 50A @75°C 40A 2 3/4" EMT 0.94 x 1.00 x 50A 47.00A 25.60A #8 AWG 10 0.18 SITE NOTES: GROUNDING NOTES: 1. A LADDER WILL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH OSHA 1. GROUNDING SYSTEM COMPONENTS SHALL BE LISTED FOR THEIR PURPOSE, AND 9 REGULATIONS. GROUNDING DEVISES EXPOSED TO THE ELEMENTS SHALL BE RATED FOR SUCH infinity cla: 2. THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE AND THIS SYSTEM IS A USE. UTILITY INTERACTIVE SYSTEM WITH NO STORAGE BATTERIES. 2. PV EQUIPMENT SHALL BE GROUNDED ACCORDING TO NEC 690.43 AND MINIMUM INFINITY HOME SOLUTIONS 3. THE SOLAR PV INSTALLATION WILL NOT OBSTRUCT ANY PLUMBING, MECHANICAL, NEC TABLE 250.122. 6405E MILL PLAIN 98661 OR BUILDING ROOF VENTS. 3. METAL PARTS OF MODULE FRAMES, MODULE RACKING, AND ENCLOSURES PHONEDUVER 1-800-81A8-0598 4. PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND PROPOSED CONSIDERED GROUNDED IN ACCORD WITH 250.134 AND 250.136(A). tNFiNrrvSOIARCOM ELECTRICAL EQUIPMENT WILL BE PROVIDED AS PER SECTION NEC 110.26. 4. EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED ACCORDING TO NEC 5. ROOF COVERINGS SHALL BE DESIGNED, INSTALLED, AND MAINTAINED IN 690.45 AND MICROINVERTER MANUFACTURER'S INSTRUCTIONS. REVISIONS Rev ACCORDANCE WITH THIS CODE AND THE APPROVED MANUFACTURER'S 5. EACH MODULE WILL BE GROUNDED USING WEEB GROUNDING CLIPS AS SHOWN IN onbeo Date INSTRUCTIONS SUCH THAT THE ROOF COVERING SERVES TO PROTECT THE MANUFACTURER DOCUMENTATION AND APPROVED BY THE AHJ. IF WEEBS ARE BUILDING OR STRUCTURE. NOT USED, MODULE GROUNDING LUGS MUST BE INSTALLED AT THE SPECIFIED GROUNDING LUG HOLES PER THE MANUFACTURER'S INSTALLATION EQUIPMENT LOCATIONS: REQUIREMENTS. 1. ALL EQUIPMENT SHALL MEET MINIMUM SETBACKS AS REQUIRED BY NEC 110.26. 6. THE GROUNDING CONNECTION TO A MODULE SHALL BE ARRANGED SUCH THAT Signature with Seal 2. WIRING SYSTEMS INSTALLED IN DIRECT SUNLIGHT MUST BE RATED FOR EXPECTED THE REMOVAL OFA MODULE DOES NOT INTERRUPT A GROUNDING CONDUCTOR TO OPERATING TEMPERATURE AS SPECIFIED BY NEC 690.31 (A),(C) AND NEC TABLES ANOTHER MODULE. 310.15(B)(2)(A)AND 310.15(B)(3)(C). 7. GROUNDING AND BONDING CONDUCTORS, IF INSULATED, SHALL BE COLORED 3. JUNCTION AND PULL BOXES PERMITTED INSTALLED UNDER PV MODULES GREEN OR MARKED GREEN IF#4 AWG OR LARGER[NEC 250.119] ACCORDING TO NEC 690.34. 8. THE GROUNDING ELECTRODE SYSTEM COMPLIES WITH NEC 690.47 AND NEC 250.50 Project Name& 4. ADDITIONAL AC DISCONNECT(S)SHALL BE PROVIDED WHERE THE INVERTER IS NOT THROUGH 250.106. IF EXISTING SYSTEM IS INACCESSIBLE, OR INADEQUATE, A Address WITHIN SIGHT OF THE AC SERVICING DISCONNECT.2.2.6 ALL EQUIPMENT SHALL BE GROUNDING ELECTRODE SYSTEM PROVIDED ACCORDING TO NEC 250, NEC 690.47 w INSTALLED ACCESSIBLE TO QUALIFIED PERSONNEL ACCORDING TO NEC AND AHJ. 0 APPLICABLE CODES. 9. GROUND-FAULT DETECTION SHALL COMPLY WITH NEC 690.41(B)(1) AND (2) TO w 5. ALL COMPONENTS ARE LISTED FOR THEIR PURPOSE AND RATED FOR OUTDOOR REDUCE FIRE HAZARDS 0 USAGE WHEN APPROPRIATE. L o DISCONNECTION AND OVER-CURRENT PROTECTION NOTES: o, 1. DISCONNECTING SWITCHES SHALL BE WIRED SUCH THAT WHEN THE SWITCH IS U w c m E STRUCTURAL NOTES: OPENED THE CONDUCTORS REMAINING ENERGIZED ARE CONNECTED TO THE 0 w N rn 1. RACKING SYSTEM & PV ARRAY WILL BE INSTALLED ACCORDING TO TERMINALS MARKED"LINE SIDE"(TYPICALLY THE UPPER TERMINALS). _/ Et rn CODE-COMPLIANT INSTALLATION MANUAL. TOP CLAMPS REQUIRE A DESIGNATED 2. DISCONNECTS TO BE ACCESSIBLE TO QUALIFIED UTILITY PERSONNEL, BE m g O 2, rn SPACE BETWEEN MODULES, AND RAILS MUST ALSO EXTEND A MINIMUM DISTANCE LOCKABLE,AND BE A VISIBLE-BREAK SWITCH i- 2 c c"i BEYOND EITHER EDGE OF THE ARRAY/SUBARRAY, ACCORDING TO RAILS 3. PV SYSTEM CIRCUITS INSTALLED ON OR IN BUILDINGS SHALL INCLUDE A RAPID w < , (3MANUFACTURER'S INSTRUCTIONS. SHUTDOWN FUNCTION TO REDUCE SHOCK HAZARD FOR EMERGENCY 0 z 2. JUNCTION BOX WILL BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. IF RESPONDERS IN ACCORDANCE WITH 690.12(A)THROUGH(D). ct ~ _ ROOF-PENETRATING TYPE, IT SHALL BE FLASHED & SEALED PER LOCAL 4. ALL OCPD RATINGS AND TYPES SPECIFIED ACCORDING TO NEC 690.8, 690.9, AND w •2 a _ REQUIREMENTS. Lu 3. ROOFTOP PENETRATIONS FOR PV RACEWAY WILL BE COMPLETED AND SEALED W/ 5. MICROINVERTER BRANCHES CONNECTED TO A SINGLE BREAKER OR GROUPED co W APPROVED CHEMICAL SEALANT PER CODE BY A LICENSED CONTRACTOR. FUSES IN ACCORDANCE WITH NEC 110.3(B). Y 4. ALL PV RELATED ROOF ATTACHMENTS TO BE SPACED NO GREATER THAN THE 6. IF REQUIRED BY AHJ, SYSTEM WILL INCLUDE ARC-FAULT CIRCUIT PROTECTION SPAN DISTANCE SPECIFIED BY THE RACKING MANUFACTURER. 2.3.6 WHEN ACCORDING TO NEC 690.11 AND UL1699B. POSSIBLE, ALL PV RELATED RACKING ATTACHMENTS WILL BE STAGGERED Sheet Name AMONGST THE ROOF FRAMING MEMBERS. INTERCONNECTION NOTES: NOTES 1. LOAD-SIDE INTERCONNECTION SHALL BE IN ACCORDANCE WITH[NEC 705.12(B)] WIRING&CONDUIT NOTES: 2. THE SUM OF THE UTILITY OCPD AND INVERTER CONTINUOUS OUTPUT MAY NOT 1. ALL CONDUIT AND WIRE WILL BE LISTED AND APPROVED FOR THEIR PURPOSE. EXCEED 120%OF BUSBAR RATING[NEC 705.12(D)(2)(3)]. Sheet Size CONDUIT AND WIRE SPECIFICATIONS ARE BASED ON MINIMUM CODE 3. THE SUM OF 125 PERCENT OF THE POWER SOURCE(S)OUTPUT CIRCUIT CURRENT ANSI B REQUIREMENTS AND ARE NOT MEANT TO LIMIT UP-SIZING. AND THE RATING OF THE OVERCURRENT DEVICE PROTECTING THE BUSBAR SHALL 2. CONDUCTORS SIZED ACCORDING TO NEC 690.8,NEC 690.7. NOT EXCEED 120 PERCENT OF THE AMPACITY OF THE BUSBAR, PV DEDICATED 11" X 17" 3. VOLTAGE DROP LIMITED TO 1.5%. BACKFEED BREAKERS MUST BE LOCATED OPPOSITE END OF THE BUS FROM THE sheet Number 4. DC WIRING LIMITED TO MODULE FOOTPRINT. MICROINVERTER WIRING UTILITY SOURCE OCPD[NEC 705.12(B)(2)(3)]. SYSTEMS SHALL BE LOCATED AND SECURED UNDER THE ARRAY W/ SUITABLE 4. AT MULTIPLE ELECTRIC POWER SOURCES OUTPUT COMBINER PANEL, TOTAL E 1.2 WIRING CLIPS. RATING OF ALL OVERCURRENT DEVICES SHALL NOT EXCEED AMPACITY OF 5. AC CONDUCTORS COLORED OR MARKED AS FOLLOWS: PHASE A OR L1-BLACK BUSBAR. HOWEVER, THE COMBINED OVERCURRENT DEVICE MAY BE EXCLUDED PHASE B OR L2-RED, OR OTHER CONVENTION IF THREE PHASE PHASE C OR L3- ACCORDING TO NEC 705.12(B)(2)(3)(C). BLUE, YELLOW, ORANGE**, OR OTHER CONVENTION NEUTRAL-WHITE OR GREY 5. FEEDER TAP INTERCONECTION(LOADSIDE)ACCORDING TO NEC 705.12(B)(2)(1) IN 4-WIRE DELTA CONNECTED SYSTEMS THE PHASE WITH HIGHER VOLTAGE TO 6. SUPPLY SIDE TAP INTERCONNECTION ACCORDING TO NEC 705.12 (A) WITH BE MARKED ORANGE[NEC 110.15]. SERVICE ENTRANCE CONDUCTORS IN ACCORDANCE WITH NEC 230.42 2.7.8BACKFEEDING BREAKER FOR ELECTRIC POWER SOURCES OUTPUT IS EXEMPT FROM ADDITIONAL FASTENING[NEC 705.12(B)(5)]. V ELECTRICAL SHOCK HAZARD M /WARNING DUAL POWER SUPPLY infinity solar TERMINALS ON BOTH LINE AND INFINITY HOME SOLUTIONS POWER SOURCE OUTPUT SOURCES:UTILITY GRID AND PV 6405 E MILL PLAIN LOAD SIDES MAY BE ENERGIZED •0 NNECTION.DO NOT RELOCATE SOLAR ELECTRIC SYSTEM VANCOUVER WA 98661 1-0008160598 IN THE OPEN POSITION + s. -1- .`'t RRENT DEVICE. 'NEWRY SOLAR.COM \ LABEL LOCATION: LABEL LOCATION: \ LABEL LOCATION: PRODUCTION/NET METER(BI-DIRECTIONAL) WHERE ALL TERMINALS OF THE DISCONNECTING MEANS MAY BE 1 MAIN SERVICE DISCONNECT NEC:2020 REVISIONS ENERGIZED IN THE OPEN POSITION,A WARNING SIGN SHALL BE I NEC:2020,705.12(B)(3)(2) NEC 690.59,705.12(DX3) Desaiption Date Rev MOUNTED ON OR ADJACENT TO THE DISCONNECTING MEANS. PER CODE(S):NEC 2020: \ PHOTOVOLTAIC AC DISCONNECT NEC 706.15(C)(4)and NEC 690.13(B) 1 L =M. MAXIMUM AC OPERATING CURRENT 25.60 AMPS LABEL LOCATION: MAIN SERVICE DISCONNECT,NEC 2020,690.13(B) NOMINAL OPERATING VOLTAGE 240 VOLTS Signature with Seal __ ��/ I LABEL LOCATION: /�WARN I N G I AC DISCONNECT,POINT OF INTERCONNECTION / NEC:2020 THIS EQUIPMENT FED BY MULTIPLE SOURCES, __I A L — IIMIMI (PER CODE:NEC 690.54) TOTAL RATING OF ALL OVERCURRENT DEVICES, EXCLUDING MAIN SUPPLY OVERCURRENT DEVICC — 0. __ Project Name& SHALL NOT EXCEED AMPACITY OF BUSBAR. x Address ,,,�,a,.r. sos r s:HLL.L.s..T`" LABEL LOCATION: MAIN SERVICE PANEL,NEC 2020,690.13(B) LABEL LOCATION: ma— CA U I I # I • W PERMANENT WARNING LABELS SHALL BE APPLIED TO . W DISTRIBUTION EQUIPMENT,AC DISCONNECT NEC:2020 PER CODE:705.12(B)(3)(3) I POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE w ce E FOLLOWING SOURCES WITH DISCONNECT(S) LOCATED AS o PHOTOVOLTAIC I SHOWN. co Lo cli DANGEROUS VOLTAGE MAY BE PRESENT AT ALL TIMES o ES 61 J SOLAR PV SYSTEM W Ce �� AC DISCONNECT EQUIPPED WITH RAPID �, 1- = a Y � ¢ w LABEL LOCATION: SHUTDOWN 1 " OC m Tn z _Q AC DISCONNECT W ' p p H O NEC:2020 Z X TURN RAPID cc LO = Li (NEC 690.13(B) m O SHUTDOWN 1— 06 00)) a W 1CO TO THE ]y_] I W—AWARNING O "OFF"POSITION TO SOLAR CZ cn ELECTRIC 1 PHOTOVOLTAIC SYSTEM — U SHUTDOWN PV PV PANELS U Y COMBINER PANEL SYSTEM AND REDUCE CZ DO NOT ADD LOADS 4-- SHOCK HAZARD U--I IN THE ARRAY C� Sheet Name LABEL LOCATION: AT INVERTER[IFC 605.11.3.1(1)&690.56(C)] G UTILITY SERVICE ENTRANCEIMETER,INVERTER/DC DISCONNECT PER CODE:NEC 2020 -' WARNING IF REQUIRED BY LOCAL AHJ,OR OTHER LOCATIONS AS LABELS REQUIRED BY LOCAL AHJ. PER CODE(S):NEC 2020:ARTICLE 690.56(C) Sheet Size PV ARRAY N ANSI B LO CO 11" X17" m t J/BA Sheet Number jI — 1 E 1.3 L _ _ — _ SOLAR PHOTOVOLTAIC SYSTEMS M IO 'C C -`7 AFC I (PER CODE:NEC 690) f 16 PV MODULES PHOTOVOLTAIC _I H— —J MAIN SERVICE PANEL L AC COMBINER PANEL SOLAR PHOTOVOLTAIC UTILITY METERii AC DISCONNECT POWER SOURCE L — — — SYSTEMS LABEL LOCATION EXPOSED RACEWAY,CABLE TRAYS,JUNCTION BOX (PER CODE:NEC 690) NEC:2020,PER CODE:NEC 690.31(D)(2) Nit 1:).1 ZXM7-SH108 Series ri- 1 Z shinesolar lOBB HAt F-CELL Black ZNSHINESOLAR iNSHINE : monocrystalline PERC PV Module infinity solar INFINITY HOME SOLUTIONS DIMENSIONS OF PV MODULE(mm) 6405 E MILL PLAIN VANCOUVER WA 98661 a PHONE:1-800-818-0598 ZXM7 -SH1 ' -.::' .... ri .' .. , I-V CURVES OF PV MODULE(400W) INFINITY SOLAR.COM Cove keno.45°C Byreeee 1 Incideni Pox o 1000 Moe 30M I REVISIONS -Trrirni,Frirtil lift MliffrP 1111M1111111111MERINWIIIIIIIIIII1111111111 r 7.\_:: ;,,(::. . lo• •Tr. ,z lezeZoollnael•BOOLV/m° Desolation Date Rev ' '.11PAI t!irrlfriliIIIIIIIII110 iillffillt1111111M11111111111111111111111E111111111, 4°, t Inetlenl load=PAC eVire• lOBB HALF-CELL Btack Monocrystattlne PERC PV Modute IIIIIMII1111111111111111111111111111111E111 ,,....,/- i ,[-[ifr-r 71-n 4) a- g it:1 l 311111.1;, ;,i4! 1 11111111EMETEIRMIUMBEffill 1. ...../ / I --- 0 1 1111M111111114fflummtun -,- ; 1 , .„ 1,111!iiimi,ltr,k; '!,rilliouNlyirlidfloi;, ill111111111W1111111111111,1111111111111111ilm . 4.coloolloael e NO NOW 4111I MO Pili'liqil:. 1111311111111E11111111MAINEHIMM °F1,11014 tildtl;1111441 le ifilf- IMINIZIMM11111131111MINE ° • 'C e le 44 ' Zs aa e• ea Signature with Seal 'it Ii1141;01014iii.Ktlfotlil: 1111111311111111111111111RIMMILifium no ca= T ;71 Voltage[%/1 ..r..';.,,ii-•,,:•-i...4:,i,. 11111111111111111121FIRMIZEIMIIMII 5 la '11111111i IONA 4110,1 390-410W 20.97% 0.55% 11111111111111111111111111E111111111111111111111 lerceentaaj ! . . P-V CURVES OF PV MODULE(400W) Lli-1,1 fiAltilop4.1,1111 1111111111111111HOMIHIERIMMIEllifill --, :,f,t r. NA tip 1141iti 411111111.111111M11111111111111111111111111111111111 1 , Cats WV•45°C :Jill Iii!PC:API iltil! POWER RANGE MAXIMUM EFFICIENCY YEARLY DEGRADATION _In./0M Wad 4 ego stew . 11111110ir Old 1141101W') umi,11111111t 11111111111111111111EM Ar.-1' -mesa t _lodeleat owsowl o BOO Wen. °'411;1;111141411.I gift 044111,44 IMIIMMIIIIIHMIMMININSUMIll1111R! • .--incielool hoe•ZOO von, °!1101:14 011110'I eiliOt illi4igli SIPRIMIRNIMESIMMINEM I /-1 ri eo \1 f p g Project Name& 414V1111.141111111'I 1119111111111111 Nig Cj 12 YEARS PRODUCT WARRANTY 0 25 YEARS OUTPUT GUARANTEE ,111111111111MIEMIIIIIIMAIIIIIIMMIL , . Address jtkili4 ii II1',.1 A;191JUILAI [11111111111111111101111111111111111111111M111111111! , 1--L._ E,11.-.2__ -_:-A--_____I a. Lii . 0 Front View Back View ------ '' 0 ti, a (EpveYCLE o 4 lo le ZO ZS 40 cc co LLJ c us Voltage[VI Cf) 12e E I a-, 10054 Common Ste-weal LLJ 0 0 CC q o 01.5'2i,1SC u '±OriLlel tOtriEnte/Itt,it_o':1(1-1,L11.61730- i- Cr)a. ri) 1.0 (3 1 ..... ane. ISO 1 ton I Frusinrerteeral tneuagercent Syocen 0 W ...,.C.1 CO E 2 ELECTRICAL CHARACTERISTICS I STC MECHANICAL DATA ISO 9301 Cduailtv Manage-cunt Sctter, -I 0 o to.. ._J re 0') Lo 1501500, 0ee ecyl cc,He5i'1 el ol 5 elely tely i,ye,leo S,,tern Nominal Power Watt Prnax(W)t 390 395 430 405 410 Solar eels Mono PEPC 15 ,25 5.15Xirtollrel Power Voltage Vrnp(V) 30.50 2070. 30 90 3110 31.20 Cells orientation 108(6413) i- ci Ce ct . 0 ILI CO .cr ilj Maximum Power Current Imp(A) 1279 1287 1295 1301 1310 Module dimension 1/24x-1134330 imm(With Frame) 03 -- 0 .13 0 CC Open Circuit Voltage Voc(V) 36 70 36.90 37.10 37 30 37.50 Weight 20.551.0 kg LC) J Go cei a- - KEY FHT�RE�® --- , Short Circuit Current Isr(A) 13.56 11 63 13 70 13 77 13 84 GI355 3 2mm High Transmission,AR Coated Tempered Glass I= CO i -11 Excellent Cells Efficiency ,;r:-: Better Weak Illumination Response Module Efficiency(%) $9.93 20.20 20.46 20.72 20.97 OnCtiOn box IP 68. 3 diodes E 1 111H,,1 5/ MBB technology reduce the distance between busbars and More power output in weak light condition such as haze, Cables 4 rriml,350 torn(With Connectors) finger grid line which is benefit to power increase. cloudy, and early morning. Connectors' MCI-compatible Sheet Name PV MODULE ELECTRICAL CHARACTERISTICS I NN1OT TEMPERATURE RATINGS' WORKING CONDITIONS ,./, Anti PID 0 Adapt To Harsh Outdoor Environment SPECIFICATION I/U Maximum Povver Priax(Wp) 291.50 495.20 299.00 302.70 306.30 NMOT 44°C x2°C Maximum system voltage 1500 V DC Ensured PID resistance through the quality control of cell Resistant to harsh environments such as salt,ammonia, SHEET manufacturing process and raw materials, sand,high temperature and high humidity environment. Maximum Power voltage vmpp(v) 28.30 28.50 28.70 28.90 29.10 Temperature coefficient of Pmax -0.35%PC Operating temperature -40°C--+65°C Sheet Size Maximum power current I raPP(A) 10.29 10.35 10.41 10 4/ 10.53 Temperature coefficient of Vac -0.29%/10 Maximum series fuse 75 A ANSI B 1-fh TIER 1 Excellent Quality Managerment System Open Circuit Voltage VoctV) 34.30 34 50 34.70 34,80 35.00 Temperature coefficient of Ise 0.05%P( Front Side Maximum Static wading Up to 5400 Pa 1 1" X 17" Global,Tier 1 bankable brand,with independently certified Warranted reliability and stringent quality assurances well Rear Side Maximum State Loading lip to 2490 Pa Sheet Number Short Circuit Current Isc(A) 10.95 11.01 11.06 11.12 11.18 advanced automated manufacturing, beyond certified requirements. ocuencii,eineicco nitioccialuctdc not eve,c ititteinto-tet'u t h Sch.et-t,or u`ttecitec „„ DS 01 r :.,r,,,,,, pno. ,a,;nor,gofferr,-•-•••,1,,ce *Cayley olo,,eleo yrdeo 4Ce-Y11.14.°1,11.a,,,,,ulti x,,rrky; .-4,4,1 a, 4°.44,Reellooce,Y,lae 4 ,onal Y,o ,4, - PACKAGING CONFIGURATION* ,11141.31t a,,,,,,4'44,roilo,,,leo xre i,,,,eCIA,l',,3 kW,ra.,r,re-,C.re/nen/1y, i--e° Improved Aesthetics .t.7.: Prece/Box 36 ' Compared to conventional modules,this full black modules Piece/Container(40'HQ) 938 have a more uniform appearance and superior aesthetics. 1 yleolocorez envoy e...Artecupon rel..,, Froarced in 1086,,ZNShnie 50131 It a worlds leading n ghtt6ath P,"rootin n etAntitaCturnr.t/V VI the anartond prt6fnnflon lnos,the cOr1.3:310 htaast;modulo 5.;/Add:lre,Zhixi Industrial Zone,fintantiangso 213251. P.R.China Tel: r86 519 6822 0233 FZI E-mail: info@znshinesolar.com twacity of 66Vi ft'oornhratt 1-666 Htati lINISrunn as a global Tier 1 PV modulo rnakttr today loshfl,dos"Inttnntt60 tt sales to more than 60 counh e6 around the olahe Note:Specifications included in this datasheet are subject to change without notice.2N5HINE reserves the right of final interpretation©ZNSHINE SOLAR 2022 I Version:2)<M7-514108 2202 E .e.fAiw.znshine:.otar.co.,-, No special undertaking or warranty for the suitability of special purpose or being installed in extraordinary surroundings is granted unless as otherwise specifically committed by manufacturer in contract document 0 110 ®i APsystemsDatasheet I DS3 Microinverter Series infinity solar Leading the Industry in INFINITY HOME SOLUTIONS L� t,, 6405E MILL PLAIN . A L T E N E R G Y POWER Solar Microinverter Technology VANCOUVER WA 98661 PHONE:1A00-818-0598 Model DS3-S DS3-L DS3 INFINITY SOLAR.COM Input Data (DC) REVISIONS Recommended PV Module Power(STC)Range 250Wp-48OWp+ 265Wp-570Wp+ ,00Wp-660Wp+ �\� DS3 SeriescetrnPt� Date Rev Peak Power Tracking Voltage 22V-48V 25V-55V 32V-SSV 7 ' Operating Voltage Range 16V-60V 16V-60V 26V-60V h The most powerful Dual -"`- Maximum Input Voltage 60V Microinverter Maximum Input Current 16A x 2 18A x 2 20A x 2 Signature with Seal One micromverter connects to two soidr modules Output Data(AC) • Max output power reaching 640V4,768VA or 880vA Maximum Continuous Output Power 640VA 768VA 880VA • Two independent input channels (MPPT) Nominal Output Voltage/Range- 240V/211V-264V • CA Rule 21(UL 1741 SA)compliant Nominal Output Current 2.66A 3.20A 3.7A • NEC 2020 690.12 Rapid Shutdown Compliant Nominal Output Frequency/Range 60Hz/59,3Hz-60.5Hz • Encrypted Wireless Zigeee Communication Power Factor(Default/Adjustable) 0.99 0.7leadin 0.7laggingProjeclName& ( 1 ) ! g... • Phase Monitored and Phasts Balanced Address . Maximum Units per 20A and 30A Branch'=' 6/9 5/7 4/6 AC Bus Cable 12AWG/10AWG 0 U Z LL Efficiency o Peak Efficiency 97% Lci)L1 cc c CEC Efficiency 96.5% Y I- Qi PRODUCT FEATURES Nominal MPPT Efficiency 99,5% C.) Wt, co cE 000 cc r— Night Power Consumption 20mW J n J ce en a) APsystems 3`a generation of dual microinverters are reaching unprecedented power outputs of 640VA or 768VA or 880VA to adapt to today's CO 2 �O o.- larger power module. With 2 independent MPPT, encrypted 2igBee signals, the DS3-5, DS3-L and DS3 benefit from an entirely new Mechanical Data I Q v cYi architecture and are fully backwards compatible with the QS1 and YC600 microinverters. Operating Ambient Temperature Range -40°F to+149°F(-40°C to+65'C) C I .r. G Storage Temperature Range -40°F to+185°F(-40°C to+85'C) trl W Zr- W The innovative and compact design make the product lighter while maximizing power production.The components are encapsulated with 0 co 1,1 a -10 silicone to reduce stress on the electronics,facilitate thermal dissipation,enhance waterproof properties,and ensure maximum reliability of the Dimensions(W x H x D) 10.3"x 8.6"x 1.6"(262mm X 218mm X41.2mm) Ln = r system via rigorous testing methods including accelerated life testing. A 24/7 energy access through Apps or web based portal facilitate Weight S.7lbs(2.6kg) oes el a- Q remote diagnosis and maintenance. DC Connector Type Staub!'MCA PV-ADBP4-52&ADSP4-52 W W The DS3 series is interactive with power grids through a feature referred to as RPC(Reactive Power Control)to better manage photovoltaic power Cooling Natural Convection-No Fans CD E. spikes in the grid. With a performance and an efficiency of 97%, a unique integration with 20%less components,APsystems DS3-S, DS3-L Enclosure Environmental Rating NEMA 6 Y and DS3 are a game changer to residential and commercial PV. Features Communication(Inverter To ECU)® Encrypted ZigBee Sheet Name ICRO Isolation Design High Frequency Transformers,Galvanically Isolated WIRING SCHEMATIC Energy Management Energy Management Analysis(EMA)system SPECIFICATION Warranty'" 10 Years Standard;25 Years Optional SHEET Sheet Size ■■mmummi ammo iiiiii iiiiii iiiiiiii iiiiiii ANSI B .■.■■■O .■■■■■■. ■ ■■■. .O■■.■. 1111111111111111111111 .■■.■■■ Compliance r■r■■■■r r■■■■■■•. III_■_■. .■■■■.■. .■■■ . .■■■■■■ Safety and EMC Compliance UL1741;CSA C2Z.2 No.107.1-16;CA Rule 21(UL 1741 SA);FCC n n .■■■■■■■ .■■■■■■ ■■ ■li muu .■ ■■■■..n■. ■■.I.■■■ 11 X 17 .■■■■■■. ■■■■■■■ ■■■■■■. ■■■■■.■. ■■omm. ■■■■■■■. Part15;ANSI C63.4;ICES-003;IEEE1547;NEC2014&NEC2017 Section Unigninn. MEIMMIIIIIIII Ilaiiiiiiii iiiianiall 11111111111111.1111111 .■■■■■■■ 690.11 DC Arc-FauIt circuit;Protection NEC2014&NEC2017 Section .■.■■■■. ■■■■■■■. ■ ■ ■■. ■■■■. ■ ■■■■�■■ ■ ■ Sheet Number .■.■■■■. .■■■■■■. u•_u_.■. .aai.■■S 111111111111111111 ..uaiii'a=■ 690.12 Rapid Shutdown of PV systems on Buildings;NEC 2020 .■.■■■■. .■■■..■. . .■■■.. .■■■■.■. .■■■■.■. ■■■■.■ DS 02 .■■■■■ • ••r�■■■. .■■■■■.• ••uu■.■ .■■■■■m• rum. Nominalwlta elfrequencyrex]ecanbeextendedbeyondnominolifrequiredbytheuttlit ®AIIRightsReseved �I■■ I SS• r '•• �•• '■ •�• �Limits may vary Refer to local requirements to define the numberofmicroinverrersperbranch Specifications subject to change without notice please ensure you are using the 11 a tt It ri ti tl tl n tl rt tl in your area. most recent update found ot web uspinsy3temscpm 1'-` ' — l ®Recommend no more than 80 inverters register to one ECU for stable communication. u IIt �tTo be eligible for the warranty APsystemsmicroinverters need to be monitored !,, 1 A "`I r via the EMA portal.Please refer950 svaemacor n to our warranty T&Cs available on APt -_ _,j �._.._��� APsystems Meets the standard requirements 111 600 Fricksen Ave NE,Suite 200 Seattle,WA 98110 0 for Olstributed Energy Resources Tel:844-666.7035 (Ut 1741)and identified with the - U apsystems.com V g us CSA Listed Mark 2022/02/15 Rev1.3 infinity solar ET.NINFINITY HOME SOLUTIONS 6405 E MILL PLAIN VANCOUVER WA 99661 Powering Business Worldwide p2.ea10n.corn PHONE:1A00 918-059a INFINITY SOLAR.COM REVISIONS DesoiPlic^ Dale Pew BR style 1-inch loadcenter • - Signature with Seal BR816L125RP UPC:786676001472 Dimensions: Project Name& • Height: 13 IN Address • Length: 3.56 IN w • Width: 11 IN Warranties: o • 10 year Lu o a Specifications: Y n' _m U w N to E • Special Features: Current design O 0 w - U1) ti@) • Type: Main lug - wCe • Amperage Rating: 125A 00 • Box Size: 7r w < o • Bus Material: Aluminum p o o • Cover: Cover includedees M a =, • Enclosure: NEMA 3R w a 2 w • Enclosure Material: Metallic co • Interrupt Rating: 10 kAIC • Main Circuit Breaker: BR • Number Of Circuits: 16 • Number Of Spaces: 8 Sheet Name COMBINER PANEL • Number Of Wires: Three-wire CERTIFICATION • Phase: Single-phase • Voltage Rating: 120/240V Sheet Size • Wire Size: #14-1 AWG Cu/AI ANSI B Supporting documents: 11" X 17" • Eatons Volume 1-Residential and Light Sheet Number Commercial • Cutler-Hammer Type CH and BR Loadcenters - DS 03 Instructions • Type BR Arc Fault Circuit Breakers and Loadcenters • Eaton Specification Sheet- BR816L125RP 3 Switching Devices 1 1 1 1 Switching Devices infinity solar Safety Switches a 3 • Safety]Switches INFINITY HOME SOLUTIONS 840.5E MILL PLAIN VANCOUVER WA 98661 i PHONE:1$80-8180598 INFINITY SOLAR.COM Product Overview Predict Description Standards and Certifications • Used to open or dose • il!_�9S REVISIONS Product Selection Guide s a cacurt • U L 50 oescdaeon Date Rev Safety Swift € • Non-fusible safety • N EMA KS-1 swrtcham promde a means ...6 _.. to manually connect or �^� ' disconnect the load from /tt, t ' the source ��L�J• • Fusa6Ge-safety switches p(OV de a means to Signature with Seal I0 manually ran and close - * a circuit and moat-current orotectinn by means of As fuses Also commonly mmonly referred DseCa/aoe CNetaFDMf ag1ry�-they ;31a-A�MMCIN't�B1e D -7Y4llr MINN parr Swricies to as a disconnect svritc}t °r disconnect Project Name& YE nB iemew SIMILL1leew manilla 9r liinu=mural BAasemelygc Maximum a a Available from SO to 1200A Address 248Yahuspnamint raNACZDCfantpaeriated FOY& hnepoeranfai Matnine F.4..z::. p L.: 11 r a} CO Dr E ri w 1= to . w-sad . . ra-1ou an-t Kai -- I- at _ 3e-ao ,, x1--zoo 14M 1&a , Y (q to m 14...r __ a Ce o, ici 1,i art 3 Z,Zarto4 6 2 ICC3 — J E..) N. ti co 2 and _ W Ce LIi Lf) 0:1 0 «h W r1 a 2tl7 2,T,tatlB 6 2,24 ax1, 3:tipl I— cia 0tit •.r r Ce = re r O IV V W CO < di 7 Os tt5 _.. es [CI0Z - 2 NEI%3a Co 07 Cl- EA* We `in SAS i W to Wan now Yes 14e Yas Vit Yes'Y p— .— W NEW 12 Pu le _- y -t Yes.'oF it?MA 6 tam YNs Y NCatatle -- '+M Wto 17EEAn. 19144. VILlIPttl ECIA 'PI r NFMA4pitdda*e Fl al@ ._ In.0.V.n4A __ __ _.. isentimitie - abs.023-90e11 — — -- Sheet Name 1 AC DISCONNECT 'e'` t AEA 'a UL CERTIFICATION . . Lpttacc, Va.ip m4tnA 'as up b MA, Sheet Size L '-m..upmmae- ANSI B :. 4pVImA 11" X 17" =s upt IDRA:, antis Sheet Number ?' Sib:6E6 of cabala nme p.111E-tr i�E:36',...00iss.rotate On meta.' ,.^rruumemay �' NEW Type 12emirates?:5-s 4MLi'an 7C UM maniam met NEMA Sri'-!-E ,:,!ttpireme rn�war a Witty Pr3,tlie screw Is attnInad ,z Ci�.1less!ctp& ,1 DS 04 Voiurna 2—Conm octal Distribution CAMP.606526—A al 2d16 rw.cestor.rnm V2-71-2 V2-71-4 VIme z—Commeetlal ofstetbetion C114a.906503E--Apn1 h 6 vrs.aatr'..cwn Switch-, , a)ev;: 0 SafetySwalfles infinitysola' INFINITY HOME SOLUTIONS 6405 E MILL PLAIN VANCOUVER WA 98661 Cross-Reference PHONE 1�90 819-0599 • INFINITY SOLARCOM Genera I-DutyGeneral-Duty, continued' i REVISIONS [E61s1 Nrllneer NWfP CarJleg Nn11DPL Demy,to, Dale Rev Ram Faloo Several Flecklc 51e/ans Sgaace O aem Fain Geseal Flaclik Simms Slime 9 Plug Fuse,Slagle-PvMc,lir 0-1VIR,120 Vic,PMMA 1 MAIM,M, I)-1,Tkele-VAll,241 VaC,PEFAA.311 7, 1W1IlNG9 TI1139 LFII'N 021IN II 0417211115 T337110 GF771511 0271 NM Plc©Rise,Tara-Pole,Threu-Wlru,244 Vac,PEIIIA 1 ID D6[mI TG322211 GF272M9 III72N00 A' OP221NO TP171 LF1119 lllIN 103 6622311111 TC77I#1 G222:111h Di77N81 Signature with Seal Feeale,limPope.Tli e- .21O Y34 MEMA 1 210 01322411111 1572249 UMW 0724AM ?0 OG2211498 163271 EF221N 92719 403 D6'WM T,17/791 UMW 0229111 IX OG7Z8P1.I 16T772 6P7234 !LIMN fW 11421MNIt I632191 EP17t2A S229NA ;X 942E11168 163273 Gl2231 WM FlUbMe,TIVU POI..TRIe0-Wle.2441he.IEMA 1B 292 0112241/60 16774 5172441 1171404 30 06YIUER 1941210 91TQ111R 977.1 04901 40s °EmmK T62775 aaSN 11775N MI 6621III TG9370 -,'.;VI 037211119 Project Name& Gm OC FSNGK 16T72G I222131I 922EN IOU MUMMA i64323i V 0321111a Address 1,4911949 12Nee-Pelt Twee-MR 2411144 HEIM 1 293 MIYNIL MGM tf' 0374N08 W 30 134321116B 164::01 132114 D27104 401 06319,1RE 10312411 'd1 19376040 Z Z RI DC32211613 164322. 5F127N 0322N GM Dfi261RE PM2919 076N0 LLJ 0 IR 13C32AMB IUM IF37711 [mix resale,TleeFPole,Four-Wire.21e Vac,FEMA;F oneOC44N61( IF-t14 I2 '4N D3249 30 66121NRe ITVNM L �Q V 11 OCZ5FGK IE02' 12 032544 671 mamma - . ,.. 1E22Nn0 Y I- c -- & DC121F '.N CK 1. T!0 1276N 'el mama , OZ7 NMO W N E 02 FOAM,111/ee-141e,F91FNYe,240 Vac,FEK4A 1 :el MIMI= IGC1249 ', OS'4NN0 J 0 ti ry Cr)3' 04321Y6B IG CO re 41D GV4%,,1 ,J'i2 IN 0 D 11 'NI UMW] W CC _ u7 CO 61 OC322NC8 TG4291 7322N T27214 gin D631YIIR ":fall Ewe I— m 0 rLo Y IS O9301168 164121 TA277N 09734 Non-Fe5I)Ie,woo-Role,iwo—WIre,2401 ,, ',E MA 3R Ce M , 0 2D3 MIMI K IG47e4 r111Th D1:4N 962211/113 I-243321H -N12I1i U L'2143 m Vr Z AEU 11C3'9Gi TG4'CS 12V11 n7EY 08272118 1GN'.f?7H GAF7229 i;IR27f6 V) E , 2 Ear DC3NNCK IG4 ZG 1-226N 0rC11 '3'; D62131R8 r3N223R G417211 029Yfal'' co 0- Q NOIFF4sade,lrio-Pole,TitIMro,240 Vac,PIEMA 1 293 0G134URK aN�1101 G4:2IP 0G11. 1.-' W W I= 22 06271116e IL821'1 NIA VA Pion-Finale,1hee-Pol4.Trine-ma,240 WC,MEMA 3R U) 6S DC MUGS IGICT2 WA 0MIER51S 3 06321Dto '7i72219 6-AF_7'' -1'' ce . OC2ZAJG8 T6N331; 4,2A 00700ONS 0L D 322090 '.`GNL279 EAF.:2 21 OCIMWI IGR714 WA OISII4 `32 DC72311213 .;fl'icdal Delifi .I1I2:>t_ 46 OCISIRI IfiC1'Z6" N/A OLDS ;3) D 23111NK 1;;NL^4D 6d9324F1 2922u0 Sheet Name Ettc O€2TYCI Mira2r) 1.6 Gila 101 MIMIC WA 14'A A AC DISCONNECT N esa an-rle,Three-pole,Three- FEWee.240 Vac, NA 1 COI maim NIA NIA VA to OCaau60 ILN:1L1 LNim21 uu,2; FrroN UL CERTIFICATION 60 DOOMS IEms L' 71F3Z 0Lt172 • Sepurale TetmS IA regueeu SheetSae 1rC... OC125191 HAM GIMM MOM Maws*Wry Iv rulrOg Cl pre;aM alien rep Nu Cm ratalag rumen rrul A rA h rruRGelaGel ANSI B 2m De>aNxl IG IQ324 59f324 IRL;AI 0.D DCII9VGIE IMWE G1f0:"S II1.625 11"l X 17" EDO 06124061 16KR176 Girr32G DIM Sheet Number DS 05 Volume 2—Comm/RNA D151edwlen CAnal nn1L—Api 1D16 gnaw mean.corn V!-T1-r 11 V infinity , fir RSTCEnterprises, Inc. INFINITY HOME SOLUTIONS21( Cyim.7tGCi(t /ti^1 ` 6405E MILL PLAIN Eau Claire, WI 703 SOLADECK VANCO1ER WA 98661 -0598 INFINITY SOLAR.COM 715-830-9997 FLASHED INV ROOF-MOUNT COMBINER/ENCLOSURES REVISIONS Description Date Rev Outdoor Photovoltaic Enclosures 0799 Series Compositirn!Cedar Roof System Signature with Seal ETL listed and labeled ,,, T,r_ Report#3171411 PRT-002 Revised May,2018 t. • UL50 Type 3R, 11 Edition Electrical equipment enclosures f Project Name& • CSA C22.2 No. 290 Nerna Type 3R Address • Conforms to UL 1741 Standard , U z 0799 Series includes: 0 >< n -^ 0799-2 Wire size 210-14 cin g F- rn 0799-5 Wire size 14-6 U w N E 0799_0 ire sze 148 _i cK rn p, w Models available in Grey,Black or Stainless Steel ,,,, to CC ro 1 cy in ;c � CC m o IL rA Q LLI Basic Specifications 0 0) i= 0 cc LnSLi 44 in rn Material options- i= — w • Powder coated, 18 gauge galvanized 90 steel , u) (1,100 hours salt spray) .q.. " Y • Stainless steel _41' � rtx-r Process- Seamless draw(stamped) Sheet Name Flashing - 15.25'x 17.25" JUNCTION BOX UL Height-3" CERTIFICATION Cavity-255 Cubic inches j F� t -- .- Sheet Size Base Plate: ANSI B • Fastened to base using toggle fastening system r �r:+ •.�,e„� 11" X 17" • 5 roof deck knockouts • Knockout sizes: (3).5", (1).75"and (1) 1" 1 I ` Sheet Number • 8",35mm slotted din rail DS 06 • Ground Block 1 Passthrough and combiner kits are available for either erect AC or DC applications_ 1�� Goss-Caked Polyethylene Insulated L) 2kV Rated PV 18-750MCM•2000 Volts•-40°Ctosl°c 'Net and Dry infinity solar _..,,,- INFINITY HOME SOLUTIONS 6405 E MILL PLAIN Description VANCOUVER WA 98661 SO�rkrrk brand has a chemica PHONE i4OLAR.0 598 ADC � INFINITY SOAR.COU cross-linked polyethylene insulation. I ` Bare C opper Application REVISIONS oe pt Date Appeoprlatr3 to use in nr l apF icatioins that require Wr 2,000 volt rating- For use in grounded interconnection and errs ungrounded Photovoltaic power systems- . 1 Construction n will Conductorm Seiridud bate coppdr conductor per ASTM B-3,B--8. Signature with Seal XLPEInsulatiOn Avadat4ein7or19y0s Kiwiversions a wetlastinnedcower - Insulation. Chemically Crass-lnikcd polyethylene arse � �; 'I � Colors: Black,Green,White,Red. Print on one side with a I4 contrwting ink. An extruded stripe and other colors are avail- able upon request_ ProAddre�e& ea 'ti1.SA industry Listings Si Standards w UL Listed as Photovoltaic Gable per Standard St ject 4703 and 44 Z " a Cable Identification 40°C.90'C Wkst and Dry Rated w o 'ADVANCED DIGITAL CABLE INC. XX AVM Gasoline and Oil Resistant II w c E rimPV WIRE OR F-IW-2 2000V OR 1. -2 600V QMRolls Corr tarrt U a $ WET OR DPP((-4oC)9R ORB DIRECT BURIAL RoMS Sunlight ResistantQ' 0 6324841" N/W-1 Flame Faring Optional US1.L1 ,r UO w co co r�E , W QLCS CL Insulation Thick- Approxirnate CD o Nominal4.D. I— in c15 Part Number AWG Strand nesa Dahl Net Weight Oe = o (mils;', (inch) m ›. Ca9 m doh 3182NPV 18 7 75 .196 18 0 H O Ce 31621+PV 16 7 75 .208 22 oo M d 3142hP/ 14 7 76 221 28 w_ 3122NPV 12 7 76 242 38 I `- w CO 3102N11311 10 7 76 264 61 Q' 30822IV 8 7 86 .314 78 3062NPV 6 7 86 .361 112 3042hPV 4 7 86 .360 166 Sheet Name $t-t=n831t 3 7 6s .427 a WIRING 3022NFV 2 7 66 .459 249 3012NW 1 19 106 .639 SPECIFICATION 3010ZNPV 110 19 105 .672. 390 Sheet Size 30202NP'V 2R) 19 106 .616 480 30302NPV WO 19 106 .667 MO ANSI B 30402NPV 40 19 105 722 737 11" X 17" 302602W/ 2E01. M 37 120 .798 879 W 33301T'14PV 300 M M 37 120 .846 1046 Sheet Number ii 303602NFV 3SOMCM 37 120 .901 1198 DS 07 jy 304002NPV 400 MGM 37 120 _946 1365 600 MGM 37 120 1.029 1673 kt y 306002193V 600 MCM 61 136 1.136 2011 0 S. 307500NPV 760liCM 61 136 1'238 2618 Tee iatssfl a=dated at bib erztleesboi YYdided to be nee as a guide h Rudd aeetim wd3b tml to be.-etiIahbi /DC I®eafee+reeytldM tU mere IreUsaiwwe ewe le smite tte*ne rplllcalen.ne apeeintonovb slatedm change mrilmew<llae mike.8M1818 6 µ"I NE: (SOO) 343 2579 • FAX: (828) 389 3022 • WWW.ADCABLE.COM C infinity solar ... . G*a�Soler Grace$filar fi�i�a.x lt'tt`iot3 srS''Era _ _ Grace 50Imr t4race safer F.?AKauN'Ivf`,fivSTEtr INFINITY HOME SOLUTIONS 6405E MILL PLAIN VANCOUVER WA 98661 ompanents - ROOF MOUNTING S Y T E M INFINITY SdLABR CDOMB Rarl s^t,r4e Eit REVISIONS C 1 S v3-URSP Desaipton Date Rev rii 1 " gecsFKe a �' Pitched Roof Mounting System( Hashing L feet) Qas' -cR-21eo _ ,x *Main meter fel Signature with Seal aa„,�..�--^" ...-.�.s , ' 1 . An0di. A16fl05•T5 —.... !�Benefits x' t ptr :�L ....., ..w.. 01 'a 't 1� III ; r Waierp actrvndtion � . ;-t, -;£ a a 1 1 •Easy Ins3allatlon a "( t t *ElBxebilita nd Com elbh f esi in the ¢ r 1 I " l� till, alliant tilt Project Name& X .. Kilikla '},.. ada. r on gee on g r Address ....- - ,y' , n 11' �• e v a bty alas■ ■ � w ,,,- �.:�— ` ---. Cmnha lnxtaiI davit errs#of spier panca, . ° a ads �ass ut� f1 -_._.- Z "` under cr inedifteren4 card itian, $' " i a �1��A��f �ij�... W •Standard ` �t tr�q: tt:rFOO1 .cO08.Ul.P.Sft-ZS 117Oand tX � �; , LlJ E okiyrr oi9'6&tiorr3l ft?utiura 1984 6 s c €d,v ci C q }, %tondo^ps ... _.. __ _.... . - C �'ri) to re M cn al r'n1 :3rti.ur.�lu9 8ui d t�j�J";ler ("'iy W CC c O .. �� r q-. p �? Y 7`- r i'bt U �- t n'' nt ce r O Y . ,l ; a rvt ' 'wCt Cl)o C/J H s ` ea M J_ ill" El ` i 4 i,,a rrt▪ 1a Rail Rail splice kit Wave piece Clamp kit " ! �x , ' r, GS,DR-2100 GC-r}R-SP uR_SSCC-C3 Gs-;st--;:�s5 < � _ '„`f i''^,t�; e .r =' 0 GS•FK-01,'02 Sheet Name i' De;erddion'.Gine nhnq Hne4 +aoaessneI 1Ata4 screwa.2N87 MOUNTING-0 t4,,,1";*,(11i,,'.,„ ;„ , ,,▪ , if06•atl'ifn,n �. Shince Roof(L Feet) x.zc3 1nsrm DATA SHEET Sheet Size 5 e 7 e ANSI B Inter clamp kit 0-module End clamp kit Craund Gip 11e X 17" GS Ir-F Gfi_A,CAA GS-EC-F G _G-ar t GS-lR-LD®S Sheet NumberDescnR1tn.Oat! t DJ 00 ti � . .. R 9 10 11 G5-A•AFt01 Ground lug Bonding jumper Flashing hook asrr w on aroautra»rr.m GS-G-GL GS-G-BJ-A GS-rK-O Tin Roof IL Feet) 1 0 infinity solar Co.ace Solar Rv uporrtv40 evSTEM INFINITY HOME SOLUTIONS 6405 E MILL PLAIN VANCOUVER WA 98661 PHONE:1-800-818-CL598 INFINITY SOLAR:COM .4'01 &so*Solar REVISIONS SYSTEMRails And Splice MAIN PARTS, GS PITCHED ROOF RACKING Campton D-module be put into GD Rail from any position via sari*i Cate Revistallation. Benefits Signature with Seal ... for easy installation rosEes . . .. .Pre-assembled any rxxiim,This , ,,,, 1 :,„ l -:...:,q?;: ._.. . ....,. . . .. „. ,,,-;,5.*': ,- 4 ;444 44..441 „., , steIa DarflpdtiortulecaneerlibefeePtilndloanil°GpsaveRalyetal fIrmne on site -,...-„,.........„.„.„._• . .....,,,,,...... Project Name& •Various Solution for the different collecinciwithitiottnse most soar -71 '._.) il...„,„, ill -..„,,,,,,,,,,,_ . ' ) 1 ° 1 ,-. -...- ,„, :. . .- ., .. ..,. Address GD Rail sod its accessories, n7ri Se residential Root, penes on the conimerola and ,„ lil di 0, , R liabilitY ..,..:,;- LLI ../i..t7 CI CT) oe E *STahaferatYckaingnda -yaeterre desired by skied enci_lteerothesrcarin.ternstaantiod unomtosnthectewextromels ZS 1170 an Lu c„ Q cc -Description 7 C.0 C.',., cc) CO E stantherdardwrIPtYings.The main supportwithtfrie components have also been tested to guarantee i -Spec- C.) •-•.. est - o) structure and load—cerrAag ea 0 ce c•1 _., 0., GS-DR-Length(Ciassical) GS-10443R-x2L8mmenosgthi ENTRcaonoil my) _1 re — 1-0 LO • LU ,.....,(X isporiec:36,0557,23: ma:1RM 14 -I- Technical Information rii co < di 7, , , .... . CO 0 Z .0 Alu - um 8.Stainless steel tiiirip : . -„: tBal C) -65 p o - n Site Commercial and Residential6R: material Ce L,0 1 Li o with the roof.up to e`0 4141 .<' - •.. . olj el Tat Angle Natural 8 RBA ,. _.., Color '4s4011 `,` •_. `.000-e:' co &titan Height up to 20m Anti-corrosive Anodized . . ',..v , ..lt • - 1r tCh:b6,e;zRaaTb.e 7:tied irto . I= N- tit Max Wind Speed up to 00m/s . • i -, CO 10 Years warranty - ER' Warranty Snow Load 14kNirrt2 Y More than 20 years „....-•... Duration S 11704 DIN 1055 standards De Fbion RailCap Sheet Name Rail Spec: mm RACKING- DATA SHEET .spi,G=S:ipt.o.D55R,45:9-Lniesemns#gtRh Mount with the cable CS2-CRC-1 engti h 4411k .-- 11(4 Sheet Size -:.. Rail Connection ANSI B -. - . - . _. . , , _,— 41111 3roundirg Washer:•,„,,,asher ' ' i• ''' '''' . . , • . • - . • ,. „.-- / .. • - . / .. . •-••• ..... ___„...:.____, GS-DR-SP SpheestNuomb9er - -' <11'10 - - -- ___ _ i.,„,,,,,,,,,,i,• -on-, Rail Splice.......—..m 150M '. -• .° . ' '''''')' a -Spec: 150mm • gr' Rail Connection sDepescrioc7i-onDR:m-RaSilPs-GZ with grounding.sa.washer.004.0r!washer xl4m."ar" C.C.13d.44 Xiamen Grace Seim Tom111146150 oweew-2,444.414f"1'46" V infinity solar � �� - A111214 �` ,. INFINITY HOME SOLUTIONS ICaSUI 2 6405 E MILL PLAIN rn::warsrxrrxeaK,+yrm PHONE 1�00-816-0598 '.n.irr+v.a wvwa^.phm - VANCOUVER WA 98661 i INFINITY SOLAR.COM REVISIONS Desaipl'wn Dale Rev Wilk n" @ CO ONE T rl � x". k '11 I h..,1 -f Signature with Se al �. T *ii - , Features =� - - - " s • Material:SU S.304 S w,vN NG.Mr jpetJii+T�ii rsaii9 And • i * c ` ` .,."'q"^.4'4"�a e - Special rib bo h surface to pierce the nturninum anodization tpr 7 Koona a=ate riaar # 71' C"'"* - Cooperated with Inter Ciarn to instal under the Rail Will .11101 ,-�' 'X p Project Name& 11110k. item Nct_ description Address r 'i :� \!� "�^ � -m c G Grounding "tp Lt.]di -' yswnr tnlaa-arr.cMxr v .:a a x &s6tl l'y}q I0.. W x ci) re E Y to to ns O ce N . rn Frlatsirns J iALc, c system q pment ground conductor M W Le --la • Connects rem to ui SOLAR ARRAY • High Pre assembly CC _ 0 c GROUNDINGSYSTEMuCa -0 Z Item No, Description col O u) t= O a 5 t Grounding Lug no to i co s Introduce •Material.AIfi045-T5 lay-in lug& Stainless Steel Cltp&A2 70 bolt w M GS Grounding Product can be used to bond solar modules 10 the aluminum rails and the CO aluminum rails to ground, so that the entire solar system is grounded and safe; Grounding products r *= Y inculde the stainless steel grounding clip and aluminum grounding lug, which are all designed to comply G GL CoPlirm Graurldantl InC1 with the requirement ofAS.5033,UL467 for bonding or grounding systems. • Material: Copper lay-in lug&Sta4ltrss Steel Clip&A2-70 bolt r: Planning Layout Sheet Name RACKING- " GROUNDING _ �l r`A'ro Sheet Size 0 Grcundir alp ; Features ANSI B 1f tl we Assn we aa •Material Braided Copper Wire&Stainless Steel Chip&A2-70 boll : 11" X 17e X Grounding Lug tr • High Pre-assembly itt • Electrically connect spliced Rails Sheet Number en B muting.iun.pe;r. Y” • Excellent electric conductivity item No_ Description .� �. DS 10 • GS-G-ail Bonding, aver NMI' afta ARP kV.: fats 15 16 a MNY.aKM:D.aa` Wa619Yw8 ■ V infinity solar CERTIFICATE OF COMPLIANCE INFINITY HOME SOLUTIONS 6405E MILL PLAIN VANCOUVER WA 98661 PHONE:1-800-818-0598 Certificate Number 20181 fk38- E499263 INFINITY SOLAR.COM Report Reference E4 99263-20 1 80927 REVISIONS Issue Date 2018-OCTOBER-08 Oedotuar Date Rev Issued to: XIAMEN GRACE SOLAR TECHNOLOGY CO LTD Bldg_ E No. 195 GaoQi BeiSan Road Signature with Seai (GaoQi Industrial Park) Xiamen Fujian 361006 CHINA. This is to certify that MOUNTING SYSTEMS, MOUNTING DEVICES, Project Name& Address representative samples of CLAMPING DEVICES AND GROUND LUGS FOR USE WITH PHOTOVOLTAIC MODULES AND PANELS c> z Mounting Systems for Use with Photovoltaic Modules and w Panels, Model GS-PR-10R. cr, E w o c3 � C O w M e Have been investigated by UL in accordance with the o cS N ` ti Standard(s) indicated on this Certificate. ! � � Lc, W CO O o Y Standard(s)for Safety: UL2703 "Standard for Mounting Systems, Mounting w a ,;; Devices, Clamping/Retention Devices, and Ground Lugs for mp Lo o use with Flat Plate Photovoltaic Modules and Panels". Lr, —J o2S C., d — Additional Information: See the UL Online Certifications Directory at w w www.ul.cornidatabase for additional information Only those prockicts beating the UL Certifiation Mark should be considered as being cowered by UL's Certification and Follow-'Up Service. Sheet Name Look for the UL Certification Mark on the product. RACKING CERTIFICATION Sheet Size ANSI B 11" X17" Sheet Number DS 11 Mlwdle& UL U.0 *my'fv �S ifoonOorsibefelf teaeMY UL M�*km geed*®WWI of(IL LC(li.r or n}in its, :kimono Si M.cc+awalata.phis[ enerltl a hook it C MO.:*e tllolOWSLcma Page I afl Cr:- i3L r; � r 1i, -10-2422:15:0if iv, v11` CITY OF TIGARD MASTER PERMIT COMMUNITY DEVELOPMENT Permit#: MST2023-00265 T 16 A IF 1) 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 06/21/2023 Parcel: 1S134CA00707 Jurisdiction: Tigard Site address: 11935 SW SUMMER CREST DR Subdivision: BURLWOOD NO.3 Lot: 42 Project: Bullock Project Description: Rooftop solar system 6.48kW with panel upgrade and(2)circuits. BUILDING Floor Areas Required Setbacks Required Stories: 0 Bedrooms: 0 First: 0 sf Basement: 0 sf Left: 0 Parking Spaces: 0 Height: 0 Bathrooms: 0 Second: 0 sf Garage: 0 sf Front: 0 Smoke Dwelling Units: 0 Third: 0 sf Right: 0 Detectors: Total: 0 sf Value: $3,170.00 Rear: 0 PLUMBING Sinks: 0 Water Closets: 0 Washing Mach: 0 Laundry Trays: 0 Rain Drain: 0 Urinals: 0 Lavatories: 0 Dishwashers: 0 Floor Drains: 0 Sewer Lines: 0 SF Rain Drains: 0 Storm Sewer: 0 Tubs/Showers: 0 Garbage Disp: 0 Water Heaters: 0 Water Lines: 0 Catch Basins: 0 Footing Drain: 0 Ice Maker: 0 Hose Bib: 0 Backwater Value: 0 Bckflw Prevntr: 0 Drywell-Trench Drain: 0 Other Fixtures: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: N Vent Fans: 0 Clothes Dryers: 0 Heat Pump: N Hoods: 0 Other Units: 0 Fum<100K: 0 Vents: 0 Woodstoves: 0 Gas Outlets: 0 Furn>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less: 0 0-200 amp: 1 0-200 amp: 0 W/Svc or Fdr: 2 Ea add'I 500 sf: 0 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All N Other: Y Other Description: Roof top solar array 6.48 kW Ecompasing: BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: ALT SF VB R-3 0 Owner: Contractor: BULLOCK,ROBERT C&KRISTIE I TML INTERNATIONAL LLC Required Items and Reports(Conditions) 11935 SW SUMMERCREST DR 6405 E MILL PLAIN BLVD TIGARD,OR 97223 VANCOUVER,WA 98661 PHONE: PHONE: 800-364-0470 FAX: Total Fees: $485.59 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR oc9-nn1-nnl n thrnii AR oc9-nnl-nn n vn, maw nhtain a rnnv of the nilac nr riirart ni,actinnc to nu mu-.by Tallinn Ffil 917 10R7 nr 1 Ann 119 91AA Issued By: //1L�� Permittee Signature: See app I« ' Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. Building Permit ApplicatiwaCE VED Residential Tigard �r''((G VV GG FOR OFFICE USE ONLY Cityof it and JUN 0 8 2023 Received <�� y� ) ,ry g Date/By: .0',�j �/FI Pen!'" t�1010,4'V h�65- 13125 SW Hall Blvd.,Tigard,OR 97223 Plan Review (, '2{I lJ Phone: 503.718.2439 Fax: So3.598at t rT OF TIGARD Date/By: 1Q �J! Other Pernur. TIGARD Inspection Line: 503.639.4175 BUILDING DIVISI�N DateReady/By: �/�� nTuns- E See Page 2for Internet: www.tigard-or.gov Notified/Method: I 3 fVY I Supplemental Information TYPE OF WORK REQUIR DATA:I-AND 2-FAMILY DWELLING ❑New construction ❑Demolition Permit fees*are based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all ❑Addition/alteration/replacement ❑■ Other:Solar equipment,materials,labor,overhead,and the profit for the CATEGORY OF CONSTRUCTION work indicated on this application. Valuation: $3170.00 ❑■ 1-and 2-family dwelling ❑Commercial/industrial ❑Accessory building ❑Multi-family Number of bedrooms: El Master builder El Other: Number of bathrooms: JOB SITE INFORMATION AND LOCATION Total number of floors: Job site address:11935 Sw Summer Crest Dr New dwelling area: square feet City/State/ZIP:Tigard, OR 97223 Garage/carport area: square feet Suite/bldg./apt.no.: Project name:Solarinstall-KBBullock Covered porch area: square feet Cross street/directions to job site: Deck area: square feet Other structure area: square feet REQUIRED DATA:COMMERCIAL-USE CHECKLIST Subdivision: Lot no.: Permit fees*are based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all Tax map/parcel no.: equipment,materials,labor,overhead,and the profit for the DESCRIPTION OF WORK work indicated on this application. Installation of 16 solar panels in 2 arrays on a roof-mounted 6.480kW PV System Valuation: $ ZN-ale 0 tS P ;\--, Existing building area: square feet t New building area: square feet ® PROPERTY OWNER ❑ TENANT Number of stories: Name:Kristie Bullock Type of construction: Address:11935 Sw Summer Crest Dr Occupancy groups: City/State/ZIP:Tigard, OR 97223 Existing: Phone:( )503-577-1659 Fax:( ) New: ® APPLICANT ® CONTACT PERSON BUILDING PERMIT FEES* (Please refer to fee schedule) Business name:TML International LLC Structural plan review fee(or deposit): Contact name:Mary Dinsmore-Smith FLS plan review fee(if applicable): Address:6405 E Mill Plain Blvd Total fees due upon application: City/State/ZIP:Vancouver,WA 98661 Amount received: Phone:( )(360)326-0650 Fax: :( ) E-mail:permit@infinityd2d.com PHOTOVOLTAIC SOLAR PANEL SYSTEM FEES* Commercial and residential prescriptive installation of CONTRACTOR roof-top mounted PhotoVoltaic Solar Panel System. Business name:TML International LLC Submit two(2)sets of roof plan with connection details and fire department access,along with the 2010 Oregon Address:6405 E Mill Plain Blvd Solar Installation Specialty Code checklist. City/State/ZIP:Vancouver,WA 98661 Permit Fee(includes plan review $180.00 and administrative fees): Phone:( )(800)818-0598 Fax:( ) State surcharge(12%of permit fee): $21.60 CCB lic.:2 8 ti1,31og6 \1\ . .'\A 'IA Total fee due upon application: $201.60 Authorized signature: 77�'1���� This permit application expires if a permit is not obtained f/ within 180 days after it has been accepted as complete. *Fee methodology set by Tri-County Building Industry Print name:Mary Dinsmore mith Date:6/5/2023 Service Board. I:\Building\Permits\BUP-RESPermitApp.doc 02/24/2011 440-4613T(I 1/02/COM/WEB) Electrical Permit Application RECEIVE I FOR OFFICE USE ONLY City of Tigard Received P . 5 III • 13125 SW Hall Blvd.,Tigard,OR 97223 JUN 0 8 2023 Date/B : ���� '®� y g Plan Review a Phone: 503.718.2439 Fax: 503.598.1960 Date/B Related Permit#: Inspection Line: 503.639.4175 CITY OF TIGARD Ready Date/By: Juris• El See Page 2 for TIGARD Internet: www.tigard-or.gov Notified/Method: Supplemental Information BUILDING DIVISIO TYPE OF WORK PLAN REVIEW ❑New construction ❑Addition/alteration/replacement Please check all that apply(submit 2 sets of plans w/items checked): O Service or feeder 400 amps or more 0 Building over three stories. ❑Demolition ❑■ Other:Solar where the available fault current 0 Marinas and boatyards. CATEGORY OF CONSTRUCTION exceeds 10,000 amps at 150 volts or 0 Floating buildings. ■ 1-and 2-familydwelling ❑Accessory building less to ground,or exceeds 14,000 0 Commercial-use agricultural ❑ ❑Commercial/industrial amps for all other installations. buildings. 0 Multi-family 0 Master builder ❑Other: 0 Fire pum p.p 0 Installation of 150 KVA or JOB SITE INFORMATION AND LOCATION 0 Emergency system. larger separately derived O Addition of new motor load of system. Job#: Job site address:10030 Sw Tigard St 100HP or more. ❑"A","E","1-2","1-3", 0 Six or more residential units. occupancy. City/State/ZIP:11935 Sw Summer Crest Dr 0Recreational vehicle arks. 0 Health-care facilities. P Suite/bldg./apt.#: Project name: 0 Hazardous locations. 0 Supply voltage for more than O Service or feeder 600 amps or more. 600 volts nominal. Cross street/directions to job site: FEE SCHEDULE Description I Qty. I Each I Total I x New residential single-or multi-family dwelling unit. Subdivision: Lot#: Includes attached garage. 1,000 sq.ft.or less 168.54 4 Tax map/parcel#: Ea.add'I 500 sq.ft.or portion 33.92 I DESCRIPTION OF WORK Limited energy,residential (with above sq.ft.) 75.00 2 Installation of 16 solar panels in 2 arrays on a roof-mounted 6.480kW PV System Limited energy,multi-family Upgrade to new 150 amp main buss with new 150 amp main breaker residential(with above sq.ft.) 75.00 2 Renewable Energy 0 See Page 2 ® PROPERTY OWNER 0 TENANT Services or feeders installation,alteration,and/or relocation Name:Kristie Bullock 200 amps or less 1 100.70 2 Address:11935 Sw Summer Crest Dr 201 amps to 400 amps 133.56 2 401 amps to 600 amps 200.34 2 City/State/ZIP:Tigard, OR 97223 601 amps to 1,000 amps 301.04 2 Phone:( )503-577-1659 Fax:( ) Over 1,000 amps or volts 552.26 2 Temporary services or feeders installation,alteration,and/or Email:bbullock1959@gmail.com relocation Owner installation: This installation is being made on property that I own which is not 200 amps or less 59.36 I intended for sale,lease,rent,or exchange,according to ORS 447,449,670,and 701. 201 amps to 400 amps 125.08 2 Owner signature:Authorized VIA Contract Date: 401 amps to 599 amps 168.54 2 ® APPLICANT E] CONTACT PERSON Branch circuits—new,alteration,or extension,per panel A.Fee for branch circuits with Business name:TML International LLC above service or feeder fee, 2 7.42 7 each branch circuit Contact name:Mary Dinsmore-Smith B.Fee for branch circuits without service or feeder fee,first Address:6405 E Mill Plain Blvd branch circuit 56.18 2 City/State/ZIP:Vancouver, WA 98661 Each add'1 branch circuit 7.42 2 Miscellaneous(service or feeder not included) Phone:( )(360)326-0650 Fax: :( ) Each manufactured or modular 67.84 2 dwelling,service and/or feeder Email:permit@infinityd2d.com Reconnect only 67.84 2 CONTRACTOR Pump or irrigation circle 67.84 2 Business name:TML International LLC Sign or outline lighting 67.84 2 Signal circuit(s)or limited-energy Address:6405 E Mill Plain Blvd 0 See Page 2 2 panel,alteration,or extension. City/State/ZIP: Each additional inspection over allowable in any of the above ty Vancouver,WA 98661 Additional inspection(1 hr min) 66.25/hr Phone:( )(800)818-0598 Fax:( ) Investigation(1 hr min) 90.00/hr Industrial plant(1 hr min) 78.18/hr Email:permit@infinityd2d.com Inspections for which no fee is CCB Lie.:223690 Electrical Lie.:C1556 Suprv.Lie.:6210S specifically listed CAhr min) 90.00/hr ELECTRICAL PERMIT FEES Suprv.Electrician signature,required:5'c L427czC_ Subtotal: Print name:Scott LeDuc Date:6/5/2023 0 Plan Review Required(25%of permit fee): State surcharge(12%of permit fee): Authorized signature: 7 Z740,441t,,�.—,'f TOTAL PERMIT FEE: This permit application expires if a permit is not obtained within 180 Print name:Mary Dinsmoi.r mith Date:6/5/2023 days after it has been accepted as complete. * Number of inspections allowed per permit. 1.\Building\Permits\ELC_PermitApp_ELR_ERE.doc Rev 06/17/2015 440-4615T(I I/05/COM/WEB Electrical Permit Application—City of Tigard Page 2—Supplemental Information Limited Energy Permit Fees: Renewable Energy Permit Fees: RESIDENTIAL WORK ONLY: FEE SCHEDULE Fee for all residential systems combined: $75.00 Description I Qty. I Each I Iota. I 3' Renewable electrical energy systems: Check Type of Work Involved: 5 kva or less 100.70 2 5.01 to 15 kva 1 133.56 133.56 2 ❑ Audio and Stereo Systems* 15.01 to 25 kva 200.34 2 Wind generation systems in excess of 25 kva: ❑ Burglar Alarm 25.01 to 50 kva 301.04 2 n Garage Door Opener* 50.01 to loo kva 552.26 2 >100 kva(fee in accordance 55226 2 with OAR 918-309-0040) ❑ Heating, Ventilation and Air Conditioning Solar generation systems in excess of 25 kva: System* Each additional kva over 25 7.42 3 ❑ Vacuum Systems* >100 kva—no additional charge 0.0 3 Each additional inspection over allowable in any of the above: ❑ Other: Each additional inspection is 66.25/hr l charged at an hourly(I hr min) Inspections for which no fee is 90.00/hr specifically listed(Yz hr min) COMMERCIAL WORK ONLY: ELECTRICAL PERMIT FEES nter o Fee for each commercial system: $75.00 Subtotal allowed per pens t Page 1): y * Number of inspections allowed per permit. (SEE OAR 918-309-0000) Check Type of Work Involved: ❑ Audio and Stereo Systems ❑ Boiler Controls n Clock Systems n Data Telecommunication Installation ❑ Fire Alarm Installation n HVAC n Instrumentation n Intercom and Paging Systems ❑ Landscape Irrigation Control* n Medical ❑ Nurse Calls ❑ Outdoor Landscape Lighting* n Protective Signaling ❑ Other: Total number of commercial systems: *No licenses are required. Licenses are required for all other installations 1\Building\Permits\ELC_PermitApp_ELR_ERE.doc Rev 06/17/2015