Loading...
Specifications (13) OFFICE COPY BtaP 2-022--0n02:1 • 1t4300 SW I t 2'"a AVE SupplementaryStructural Calculations For Housing Authority of Washington County - The Ridge Remodel - RFI 69 Washington County, Or Pinnacle Architecture February 07, 2023 FE Job Number— 21-T076 StPVGTu444 51411PE arr C? �, • -EGON rNY T.IS° EXPIRES These Calculations Are Void If Seal And Signature Are Not Original FROELICH ENGINEERS " * * LIMITATIONS * * * ENGINEERING DESIGN IS BASED UPON INFORMATION PROVIDED BY THE CLIENT, WHO IS SOLELY RESPONSIBLE FOR ACCURACY OF SAME. NO RESPONSIBILITY AND/OR LIABILITY IS ASSUMED BY,OR IS TO BE ASSIGNED TO THE ENGINEER FOR ITEMS BEYOND THAT SHOWN ON THESE SHEETS. www.froelich-engineers.com PORTLAND(HQ) 503.624.7005 BEND 541.383.1828 DENVER 720.799.1001 CONCRETE TOPPING SLOPED LESS THAN VRF CEILING MOUNTED IN CLOSET, 5%AS REQUIRED TO RAMP TO NEW ADD ACCESS PANEL TO ALLOW FOR LA ND5 -0 G REMOVAL/REPLACEMENT OF UNIT - NEW 2x10 DF#2 / JOISTS AT 16"OC--N, 5 0 X CLOSET Co SPECIAL INSPECTIONS NOTE: V30 . — `) 07, REMOTE HOOD ,° _ \/ \/ _ f' NEW 4x10 DF#2 --N SWITCH PERIODIC SPECIAL INSPECTIONS «4 HEADER W/(2)2x4 m REQUIRED FOR EPDXY REBAR "' DF#2 TRIMMER I` NEW 12"Wx10"DxCONT INSTALLATION. i` KITCHEN A3 STUDS&(1)2x4 DF F B4 11 82 FOOTING W/(2)#4 V16 #2 KING STUD Th,I ^BARS LONG&#4 BARS SPECIAL INSPECTIONS NOT :« I DW r_ REQUIRED FOR CONCRETE PER le-m� A4 B3 TRANS AT 12"OC al �� OSSC 1705.3 5-2 ' I :1".'. — _ I e$1 ALIGN I --V32I-.- WH iD b , NOTE:NEW FOOTINGS NEW 2x4 BEARING CONCRETE TO BE 3,000 psi WALL-2x4 DF#2 \ 1 NEW 2x4 MINIMUM. AT SLAB POUR-BACK, - 27BEARING WALL- STUDS AT 16"OC I PROVIDE 4"CONC SLAB ON - wh�� 2x4 DF#2 STUDS GRADE W/#3 BARS AT 18"OC EA L — — — ' I I I AT 16"OC A WAY — — J I re LIVING ROOM i Ial / 3 -6' ADD 2x FULL HEIGF NOTE:EPDXY(N)FOOTINGS V30 BEDROOM / AND SLAB POUR BACK AREA TO - BLOCKING (E)CONC SLAB ON GRADE W/#3 0 \LBETWEEN JOISTS CLOSET ALIGNED OVER(N) BARS AT 18"OC(MIN(2)PER :, FOOTING FACE)AT SLAB BEARING WALL MID-DEPTH. EMBED 4"MIN INTO Q v30 BELOW W/0.148"x3TOE NAILS AT 8"O( SLAB. USE SIMPSON SET-XP OR 3G EPDXY. s 5.eiq TO DBL TOP PL r? v . ae . :, i -- <tii,.a3;, _ A, /2' 0"// 11'_0" NEW CONCRETE LANDING AT 1/2"MAX BELOW FINISH FLOOR � " R EXISTING 2x10 AT ADA UNITS ONLY,SLOPE 2% DF#2 JOISTS AT MAX AWAY FROM BUILDING °" 16"OC. VERIFY IN FIELD. MAX SPAN=13'-0° (N) ROI AT. 2E1 BEDROOM ADA- FLOOR PLAN 1/4" = 11-0" RES RR- FOR CALCULATION REFERENCE ONLY - NOT FOR CONSTRUCTION - SEE RFI 69 RESPONSE FOR CONSTRUCTION DRAWINGS Client: Pinnacle Architecture Project: The Ridge ADA Proj.#: 21-T076 Date: 11/23/2022 By: BTS FROELICH ENGINEERS Dead Load Calculations Floor Dead Load Component Weights I Actual(psf)I Comments Framing 3 Joist Framing Sheathing 2 5/8" shth Floor Covering 15.625 1-1/2" Floor Topping(Gyperete 125 lbs/ft3) Mechanical 1 Ceiling 2.8 (1)5/8"gyp Flooring 1 Misc. 0.4 Total= 26.0 psf ,porticind (HO) 503-624-7005 r rinctc-cc- rrc4 ftt-cTiAr - PAGE / 4iik Li Bend PROJECT TKe "ei 4..e. ADA 541-383-1828 ' [ I Deny( NUMBER.0 I—70 76 720-799-1001 FROELICH DATE' 2./ t ENGINEERSA BY S TS .Ak LNI \A)cltt : e litz q'-og - 2 .A Si-oots • DLz: 2. C. ?sf • Iljz Z$ C Li 0 rsf = Lto .2. )( *2 aft 1, OC 1Z' )x I COttt• Id (L2.) ci4 Beirs 1_01104, - .44TS T-NPS eC9174 • Recider : -san = CI' 1/4 D 2C II 2:6*C 40 . ft . USf < #z ks) (2) 2x47)F-ii2 -7—i-1•Aimer & 00 2-1/4-4 K;t#1 . S-6401 - (E) Jo;StS : . Spet 4E) 2k l0 bT OZ. a-fr 16110C 3-0s are kolect4c,it dek/ S:01:1,V; Spc44 • Ackert COMPANY PROJECT tit WoodWorks® SOFTWARE FOR WOOD DESIGN. Feb. 6, 2023 15:17 Wall Studs Design Check Calculation Sheet WoodWorks Sizer 2019 (Update 4) Loads: Load Type Distribution Location [ft] Magnitude Unit Start End Start End • Loadl Dead Axial UDL (Ecc. = 0.00") 286 plf Load2 Live Axial UDL (Ecc. = 0.00") 440 plf Load3 Live Full Area 5.00 (16.0") psf Self-weight Dead Axial UDL 8 plf Reactions (Ibs): 9'co v D 9' Unfactored: Lateral: Dead Live 30 30 Axial: Dead 393 393 Live 587 587 Factored: L->R 30 30 Load comb #2 #2 Lumber Stud, D.Fir-L, No.2, 2x4 (1-1/2"x3-1/2") Support: Lumber Stud Bottom plate, D.Fir-L Stud; Bearing length = stud thickness; continuous lower support Spaced at 16.0" c/c; Total length: 9'; Volume = 0.3 cu.ft. Pinned base; Load face=width(b); Ke x Lb: 1.0 x 0.0 = 0.0 ft; Ke x Ld: 1.0 x 9.0 = 9.0 ft; Repetitive factor: applied where permitted (refer to online help); This section PASSES the design code check. Analysis vs. Allowable Stress and Deflection using NDS 2018 : Criterion Analysis Value Design Value Unit Analysis/Design Shear fv = 9 Fv' = 180 psi fv/Fv' = 0.05 Bending(+) fb = 264 Fb' = 1552 psi fb/Fb' = 0. 17 Axial fc = 187 Fc' = 462 psi fc/Fc' = 0.40 Axial Bearing fc = 187 Fc* = 1552 psi fc/Fc* = 0.12 Support Bearin fcp = 187 Fcp = 781 psi fcp/Fcp = 0.24 Combined (axial compression + side load bending) Eq.3. 9-3 = 0.43 Dead Defl'n negligible Live Defl'n 0.11 = L/941 0. 90 = L/120 in 0.13 Total Defl'n 0.11 = L/941 0. 90 = L/120 in 0.13 Design Notes: 1. Analysis and design are in accordance with the ICC International Building Code (IBC 2018) and the National Design Specification (NDS 2018), using Allowable Stress Design (ASD). Design values are from the NDS Supplement. 2. Please verify that the default deflection limits are appropriate for your application. Project Title: Engineer: Project ID: Project Descr: Wall Footing Project File:HAWC-Aloha, Bonita,Villager Calculations.ec6 LIC#:KW-06014743,Buitd:20.22.3.31 FROELICH CONSULTING ENGINEERS (c)ENERCALC INC 1983-2022 DESCRIPTION: (N) Bearing Wall Footing Code References Calculations per ACI 318-14, IBC 2018, CBC 2019,ASCE 7-16 Load Combinations Used :ASCE 7-16 I General Information Material Properties Soil Design Values fc:Concrete 28 day strength = 3.0 ksi Allowable Soil Bearing = 1.50 ksf fy: Rebar Yield = 60.0 ksi Increase Bearing By Footing Weight = No Ec:Concrete Elastic Modulus = 3,122.0 ksi Soil Passive Resistance(for Sliding) = 250.0 pcf Concrete Density = 145.0 pcf Soil/Concrete Friction Coeff. = 0.30 N Values Flexure = 0.90 Shear = 0.750 Increases based on footing Depth Analysis Settings Reference Depth below Surface = ft Min Steel%Bending Reinf. = Allow. Pressure Increase per foot of depth = ksf Min Allow%Temp Reinf. = 0.00180 when base footing is below = ft Min.Overturning Safety Factor = 1.0: 1 Increases based on footing Width Min.Sliding Safety Factor = 1.0: 1 Allow. Pressure Increase per foot of width = ksf AutoCalc Footing Weight as DL : Yes when footing is wider than = ft Adjusted Allowable Bearing Pressure = 1.50 ksf Dimensions Reinforcing Footing Width = loft Footing Thickness = 10.0 in Bars along X-X Axis Wall Thickness = 3.50 in Rebar Centerline to Edge of Concrete... #of Bars in 12"Width = 2 Wall center offset at Bottom of footing = 3.0 in Reinforcing Bar Size = # 4 from center of footing = 0 in 3-t 2' Z1 F iy Jm #4 Bars — 1 f. 2 X X Section L ooking to+Z Applied Loads D Lr L S W E H P: Column Load = 0.2860 0.440 k OB: Overburden = ksf V-x = k M-zz = k-ft Vx applied = in above top of footing Project Title: Engineer: Project ID: Project Descr: Wall Footing Project File:HAWC-Aloha,Bonita,Villager Calculations.ec6 J LIC#:KW-06014743,Build:20.22.3.31 FROELICH CONSULTING ENGINEERS (c)ENERCALC INC 1983-2022 DESCRIPTION: r(N) Bearing Wall Footing DESIGN SUMMARY Design OK Factor of Safety Item Applied Capacity Governing Load Combination PASS n/a Overturning-Z-Z 0.0 k-ft 0.0 k-ft No Overturning PASS n/a Sliding-X-X 0.0 k 0.0 k No Sliding PASS n/a Uplift 0.0 k 0.0 k No Uplift Utilization Ratio Item Applied Capacity Governing Load Combination PASS 0.5646 Soil Bearing 0.8468 ksf 1.50 ksf +D+L PASS 0.006285 Z Flexure(+X) 0.07475 k-ft 11.894 k-ft +1.20D+1.60L PASS 0.001930 Z Flexure(-X) 0.02296 k-ft 11.894 k-ft +0.90D PASS n/a 1-way Shear(+X) 0.0 psi 82.158 psi n/a PASS 0.0 1-way Shear(-X) 0.0 psi 0.0 psi n/a Detailed Results Soil Bearing Rotation Axis& Actual Soil Bearing Stress Actual/Allowable Load Combination... Gross Allowable Xecc -X +X Ratio , D Only 1.50 ksf 0.0 in 0.4068 ksf 0.4068 ksf 0.271 , +D+L 1.50 ksf 0.0 in 0.8468 ksf 0.8468 ksf 0.565 ,+D+0.750L 1.50 ksf 0.0 in 0.7368 ksf 0.7368 ksf 0.491 ,+0.60D 1.50 ksf 0.0 in 0.2441 ksf 0.2441 ksf 0.163 Overturning Stability Units:k-ft Rotation Axis& Load Combination... Overturning Moment Resisting Moment Stability Ratio Status Footing Has NO Overturning Sliding Stability Force Application Axis Load Combination... Sliding Force Resisting Force Sliding SafetyRatio Status Footing Has NO Sliding Footing Flexure Flexure Axis&Load Combination Mu Which Tension @ Bot. As Req'd Gym.As Actual As Phi*Mn k-ft Side? or Top? in^2 inA2 in^2 k-ft Status ,+1.40D 0.03571 -X Bottom 0.216 Min Temp% 0.4 11.894 OK ,+1.40D 0.03571 +X Bottom 0.216 Min Temp% 0.4 11.894 OK ,+1.20D+1.60L 0.07475 -X Bottom 0.216 Min Temp% 0.4 11.894 OK ,+1.20D+1.60L 0.07475 +X Bottom 0.216 Min Temp% 0.4 11.894 OK ,+1.20D+L 0.0582 -X Bottom 0.216 Min Temp% 0.4 11.894 OK ,+1.20D+L 0.0582 +X Bottom 0.216 Min Temp% 0.4 11.894 OK ,+1.20D 0.03061 -X Bottom 0.216 Min Temp% 0.4 11.894 OK ,+1.20D 0.03061 +X Bottom 0.216 Min Temp% 0.4 11.894 OK ,+0.90D 0.02296 -X Bottom 0.216 Min Temp% 0.4 11.894 OK ,+0.90D 0.02296 +X Bottom 0.216 Min Temp% 0.4 11.894 OK One Way Shear Units:k Load Combination... Vu @-X Vu @+X Vu:Max Phi Vn Vu/Phi*Vn Status +1.40D 0 psi 0 psi 0 psi 82.158 psi 0 OK +1.20D+1.60L 0 psi 0 psi 0 psi 82.158 psi 0 OK +1.20D+L 0 psi 0 psi 0 psi 82.158 psi 0 OK +1.20D 0 psi 0 psi 0 psi 82.158 psi 0 OK +0.90D 0 psi 0 psi 0 psi 82.158 psi 0 OK • COMPANY PROJECT 1111 WoodWorks® SOF!WARE FOR WOOD DESIGN Feb.6,2023 15:31 Header Design Check Calculation Sheet Wood Works Sizer 2019(Update 4) Loads: Load Type Distribution Pat- Location [ft] Magnitude Unit tern Start End Start End Loadl Dead Full UDL 286.0 plf Load2 Live Full UDL 440.0 plf Self-weight Dead Full UDL 7.7 plf Maximum Reactions (Ibs), Bearing Capacities (Ibs) and Bearing Lengths (in) : 3'-9" — -- 4 4 0' 3'-6.63" Unfactored: Dead 550 550 Live 825 825 Factored: Total 1375 1375 Bearing: Capacity Beam 3281 3281 Support 3633 3633 Des ratio Beam 0.42 0.42 Support 0.38 0.38 Load comb #2 #2 Length 1.50* 1.50* Min req'd 0.63 0.63 Cb 1.00 1.00 Cb min 1.00 1.00 Cb support 1.11 1.11 Fcp sup 625 625 *Minimum bearing length setting used: 1-1/2"for end supports Lumber-soft, D.Fir-L, No.2,4x10(3-1/2"x9-1/4") Supports:All-Timber-soft Beam, D.Fir-L No.2 Total length:3'-9.0";Clear span:3'-6.0";Volume=0.8 cu.ft. Lateral support:top=at supports,bottom=at supports; This section PASSES the design code check. Analysis vs.Allowable Stress and Deflection using NDS 2018: Criterion Analysis Value Design Value Unit Analysis/Design Shear fv = 33 Fv' = 180 psi fv/Fv' = 0.18 Bending(+) fb = 278 Fb' = 1074 psi fb/Fb' = 0.26 Dead Defl'n 0.00 = < L/999 Live Defl'n 0.00 = < L/999 0.09 = L/480 in 0.05 Total Defl'n 0.01 = < L/999 0.18 = L/240 in 0.05 Design Notes: 1.Analysis and design are in accordance with the ICC International Building Code(IBC 2018)and the National Design Specification(NDS 2018), using Allowable Stress Design(ASD). Design values are from the NDS Supplement. 2. Please verify that the default deflection limits are appropriate for your application. 3.Sawn lumber bending members shall be laterally supported according to the provisions of NDS Clause 4.4.1. COMPANY PROJECT 1 WoodWorks® ,( 755 ARE FOR L5'()OD Uf SIC:1 Feb. 7, 2023 09:52 Existing Joists Design Check Calculation Sheet WoodWorks Sizer 2019(Update 4) Loads: Load Type Distribution Pat- Location [ft] Magnitude Unit tern Start End Start End Loadl Dead Full Area 26.00 (16.0") psf Load2 Live Full Area 40.00 (16.0") psf Self-weight Dead Full UDL 3.3 plf Maximum Reactions (Ibs), Bearing Capacities (Ibs) and Bearing Lengths (in) : --- 13' 0' 12'-9.63" Unfactored: Dead 246 246 Live 347 347 Factored: Total 593 593 Bearing: Capacity Joist 1406 1406 Support 1758 1758 Des ratio Joist 0.42 0.42 Support 0.34 0.34 Load comb #2 #2 Length 1.50* 1.50* Min req'd 0.63 0.63 Cb 1.00 1.00 Cb min 1.00 1.00 Cb support 1.25 1.25 Fcp sup 625 625 *Minimum bearing length setting used: 1-1/2"for end supports Lumber-soft, D.Fir-L, No.2, 2x10 (1-1/2"x9-1/4") Supports:All-Timber-soft Beam, D.Fir-L No.2 Floor joist spaced at 16.0"c/c;Total length: 13'; Clear span: 12'-9.0";Volume= 1.3 cu.ft. Lateral support:top=continuous, bottom=at supports; Repetitive factor: applied where permitted(refer to online help); This section PASSES the design code check. Analysis vs. Allowable Stress and Deflection using NDS 2018 : Criterion Analysis Value Design Value Unit Analysis/Design Shear fv = 55 Fv' = 180 psi fv/Fv' = 0.31 Bending(+) fb = 1049 Fb' = 1138 psi fb/Fb' = 0.92 Dead Defl'n 0.14 = < L/999 Live Defl'n 0.20 = L/754 0.43 = L/360 in 0.48 Total Defl'n 0.42 = L/364 0.64 = L/240 in 0.66 Design Notes: 1.Analysis and design are in accordance with the ICC International Building Code(IBC 2018)and the National Design Specification (NDS 2018), using Allowable Stress Design (ASD). Design values are from the NDS Supplement. 2. Please verify that the default deflection limits are appropriate for your application. 3. Sawn lumber bending members shall be laterally supported according to the provisions of NDS Clause 4.4.1.