Loading...
Report -'3 240 u- e* 14 • Dyna-Thread® - M-COAT® Submittal Data Sheet • -7358 6 Dur hp,,,r1 4 O Full Line Sch-40 Replacement Dyna-Thread—M-COAT Specifications Dyna-Thread"'-M-Coat'sprinkler pipe represents an engineering NPs Nominal I.D. Wt. Wt.(H20 Filled) CRR CRR advancement for the sprinkler pipe industry.It combines the safety In;mm In;mm Lbs/Ft;kg/m Lbs/Ft;kg/m Unthreaded Threaded and longevity of traditional Sch-40 pipe with quality and superior 1" 1.080 1.330 1.75 11.39 1.00 hydraulic advantages. _25 27.4 2.0 2.60 - - 11/4" 1.408 1.870 2.54 9.50 1.00 O Comparison to Schedule 40 32 35.8 2.8 3.78 — — 1'k" 1.639 2.290 3.22 9.14 1.00 Dyna-Thread-M-Coat inside diameter is up to 3.6%larger than Sch-40 40 41.6 3.4 4.79 — - giving it superior hydraulics.Also,when used in combination with Dyna- 2,. 2.104 3.050 4.57 8.41 1.00 Flow-M-Coat pipe,down sizing often occurs.Dyna-Thread is fully listed and 50 53.4 4.5 6.80 - - approved UL, ULC,and FM for fire sprinkler applications.The life expectancy of Dyna-Thread-M-Coat and Sch-40 are equal based on the calculated wall 0 c 0 thicknesses per UL.The consistent quality of steel used to make Dyna-Thread- ,,,ROVE, M-Coat facilitates smooth threading and lower maintenance costs.The exterior of Dyna-Thread-M-Coat is protected by a clean,durable mill coating for O American Made •extended shelf life and easy paint application.With its increased strength Manufactured at one of 3 U.S.Facilities and is available and lighter weight,Dyna-Thread-M-Coat reduces installation fatigue and through distributors in the USA,Canada,Mexico,and is ideal for retro-fit applications.Corrosion Resistance Ratio(CRR) is a UL Latin America. (Underwriters Laboratory)term for the estimated life expectancy of a pipe joint. This is based on the calculated wall thickness at the base of the first exposed ®Specifications & Approvals thread,assumed to be the weakest point of the pipe length.Dyna-Thread- M-Coat and Sch-40 have the same calculated wall thicknesses at this point Dyna-Thread-M-Coat pipe is manufactured to meet:ASTM A and are both assigned the same CRR of 1.00. 135,Type E Grade A,and is in compliance with NFPA-13.All sizes of Dyna-Thread-M-Coat are rated at 300 psi working O Comparison to L.W.T. Pipe pressure.Dyna-Thread-M-Coat is UL and ULC Listed for wet, More wall thickness at the thread(CRR=1.00)gives Dyna-Thread-M-Coat dry and pre action sprinkler systems and FM Approved for better life expectancy than lightwall threadable pipe joints.Dyna-Thread- use in wet systems.Dyna Thread-M-Coat is approved for all M-Coat is approved for standard hanger spacing(15 ft.O.C.),can be used as threaded couplings and welded outlets and is suitable for all earthquake sway bracing,and is safe to use as drops.Dyna-Thread-M-Coat roll grooved,and plain end fittings. See lis in�jQGr� pj� is safer to weld on than many zinc coated lightwall threadable pipe products. L` V uL'll Dyna-Thread-M-Coat is more widely accepted than lightwall threadable where Sch-40 is specified. JUN -5 214 7J CITY OF TIGARI) r BUILDING DIVISION Project: Sprinkler Contractor: Date: Engineer: Specification Reference: System Type: Locations: Comments: allied t Customer Service:(800)882-5543 Fax:(800)659-7730 www.alliedtube-sprinkler.com l�J • 16100 S Lathrop Ave • 11350 Norcom Rd. • 2525 N 27th Ave. TUBE&CONDUIT' Harvey,IL 60426 Philadelphia,PA 19154 Phoenix,AZ 85009 " atkor@ 02013 Atkore International,Inc.All Rights Reserved.STP-53-4M-1301 46. Ductile Iron Fittings - Class 300 UL/FM I QUALM Iws C ® uS APPROVED • Fig. 35E 3- 90°Elbow LISTED A Size A Packing Weight M�Ar�. Part Number ••.4, in in Inner Master lb __iii 1/2 35E 3004 1.13 100 200 0.2 3/4 35E 3006 1.31 70 140 0.3 I i N A 1 35E 3010 1.50 40 80 0.5 Mi t 1-1/4 35E 3012 1.75 25 50 0.8 1-1/2 35E 3014 1.94 18 36 1.1 2 35E 3020 2.25 10 20 1.8 . 2-1/2 35E 3024 2.70 4 8 3.2 Fig. 35RE3- 90°Reducing Elbow SB � Size Part Number A B Packing Weight wr.- in in in Inner Master lb 3/4 x 1/2 35RE3006004 1.20 1.22 80 160 0.3 I, 1 x 1/2 35RE3010004 1.26 1.36 70 140 0.4 yA6•I IA 1 x 3/4 35RE3010006 1.38 1.45 50 100 0.4 1-1/4 x 1/2 35RE3012004 1.34 1.53 35 70 0.5 1-1/4 x 3/4 35RE3012006 1.45 1.63 35 70 0.6 1-1/4x 1 35RE3012010 1.58 1.67 30 60 0.7 1-1/2 x 1/2 35RE3014004 1.52 1.75 30 60 0.6 1-1/2 x 3/4 35RE3014006 1.52 1.75 25 50 0.7 1-1/2 x 1 35RE3014010 1.65 1.80 20 40 0.8 • 1-1/2 x 1-1/4 35RE3014012 1.82 1.88 18 36 1.0 2 x 1/2 35RE3020004 1.60 1.97 18 36 1.0 2 x 3/4 35RE3020006 1.60 1.97 18 36 1.0 , 2 x 1 35RE3020010 1.73 2.02 16 32 1.2 2 x 1-1/4 35RE3020012 1.90 2.10 12 24 1.3 D 2 x 1-1/2 35RE3020014 2.02 2.16 10 20 1.5 U 2-1/2 x 1-1/2 35RE3024014 2.16 2.51 6 12 2.2 C 2-1/2 x 2 35RE3024020 2.39 2.60 6 12 2.5 T 1 Fig. 35F 3-45°Elbow L E Size Part Number A Packing Weight '' ti, in in Inner Master lb I� �, 1/2 35F 3004 0.88 150 300 0.2 3/4 35F 3006 0.98 80 160 0.3 z4 1 35F 3010 1.13 40 80 0.5 1-1/4 35F 3012 1.29 25 50 0.7 IA 1-1/2 35F 3014 1.44 20 40 1.0 /- 2 35F 3020 1.69 10 20 1.6 2-1/2 35F 3024 1.95 4 8 2.7 ( t` Fig. 35T 3- Tee Size Part Number A Packing Weight in in inner Master lb al _ A 1/2 35T 3004 1.13 80 160 0.3 3/4 3513006 1.31 30 60 0.5 1 35T 3010 1.50 25 50 0.7 �`I 1-1/4 35T 3012 1.75 10 20 1.1 A A 1-1/2 35T 3014 1.94 10 20 1.5 2 35T 3020 2.25 6 12 2.4 2-1/2 35T 3024 2.70 4 8 4.3 111 SMITH-COOPER INTERNATIONALS • TOLL FREE 1-800-766-0076 • FAX(323)890-4456 • www.sminccooper.cum Pipe Hangers . Fig.200- "Trimline"Adjustable Band Hanger (B-Line Fig.B317ONF) ®TOLCO Fig.200F- "Trim line" Adjustable Band Hanger with Felt Lining (B-Line Fig.B311ONFF) c C us Fig.200C - "Trimline" Adjustable Band Hanger with Plastic Coated (B-Line Fig.B317ONFC) LISTED Fig.200S - "Trimline" Adjustable Band Hanger with Non-Captured Nut Size Range: "V" Fig. 200 - 1/2" (15mm)thru 8" (200mm)pipe Material: Steel, Pre-Galvanized to G90 specifications y Function: For fire sprinkler and other general piping purposes. Knurled -- �\ swivel nut design permits hanger adjustment after installation. c. Features: ,..� @ >.,.� T • (1/2" (15mm)thru 2" (5omm)) Flared edges ease installation for all pipe _ ��► , types and protect CPVC plastic pipe from abrasion. Captured design - �°° keeps adjusting nut from separating with hanger. Hanger is easily / B installed around pipe. For hanger with non-captured nut order Fig. 200S. • (21/2" (65mm)thru 8" (20omm))Spring tension on nut holds it securely in l \ hanger before installation.Adjusting nut is easily removed. ,s' Approvals: Underwriters Laboratories listed(1/2" (15mm)thru 8" (200mm)) ' Fig.200-1A.280 /s in the USA(UL)and Canada(cUL)for steel and CPVC plastic pipe and Fig 2001m2002 Fe +heetoo4 Factory Mutual Engineering Approved(FM)(3/4" (20mm)thru 8" (200mm)). Conforms to Federal Specifications WW-H-171 E&A-A-1192A,Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69&SP-58, Type 10. Maximum Temperature: 650°F(343°C) .1616. . . ' Finish: Pre-Galvanized. Stainless Steel m Ar aterials will be supplied with (2) hex nuts ° in place of a knurl nut. Order By: Figure number and pipe size . / Designed to meet or exceed requirements of FM DS 2-0. ti Fig.200 Fig.200C Fig.200F Pipe Size Rod Size A B Approx.Wt/100 Part No. in. (mm) in. (mm) in. (mm) lbs. (kg) 200-1/2 1/2` (15) 3/8"-16 31/8" (79.4) 25/8" (663) 11 (5.0) 200-3/4 314` (20) 3/8%16 31/8" (79.4) 21/2' (63.5) 11 (5.0) / 200-1 1" (25) 3/8"-16 33/8' (85.7) 25/8" (66.7) 12 (5.5) f 200-11/4 11/4" (32) 3/8"-16 33/4" (94.0) 27/8" (73.0) 13 (5.9) r " 1 200-11/2 11/2" (40) 3/8"-16 37/8' (98.4) 27/8" (73.0) 14 (6.4) 4 200-2 2' (50) 3/8"-16 41/2" (114.3) 3" (76.3) 15 (6.9) 4 200-21/2 21/2" (65) 3/8"-16 55/8" (142.9) 41/8" (104.7) 27 (12.3) 200-3 3' (75) 3/8"-16 57/8' (149.1) 4" (101.6) 29 (13.3) Fig.200S 200-31/2 31/2' (90) 3/9"-16 73/8 (187.3) 51/4" (133.3) 34 (15.6) 200-4 4" (100) 3/8"-16 73/8" (187.3) 5" (127.0) 35 (16.0) 200-5 5" (125) 1/2"-13 91/8" (231.8) 61/4' (158.7) 66 (30.2) " 200-6 6" (150) 1/2"-13 101/8" (257.2) 63/4" (171.4) 73 (33.4) 200-8 8" (200) 1/2"-13 131/8' (333.4) 83/4" (222.2) 136 (62.3) All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. B-Line Fire Protection Solutions 21 by E:T•N Threaded Accessories B3205 - Threaded Rod (right-hand threads - both ends) (TOLCO Fig. 103) ' , B3205L - Threaded Rod (right& left hand threads) -" TL Size Range: 3/s"-16 thru 3"-4 rod Specif Length < l�� Material: Steel /� Function: Recommended for use as a hanger support in hanger assemblies. n �1+ Rod is threaded on both ends with right hand threads of the length shown.Also �1 A available with left and right hand threads-specify Fig. B3205L when ordering. 1� rnreadsize Maximum Temperature: 750°F(399°C) Finish: Plain. Contact B-Line for alternative finishes and materials. Order By: Part number, rod size. length and finish i Standard Design Load Thread Size Thread Length TL 650°F(343°C) 750°F(399°C) Part No. A in. (mm) Lbs. (kN) Lbs. (kN) B3205-3/a x'L' 3/8°-16 21/2" (63.5) 730 (3.25) 572 (2.54) B3205-1/2 x'L' 1/2"-13 21/2" (63.5) 1350 (6.00) 1057 (4.70) 83205-5/8 x'L' 5/8"-11 21/2" (63.5) 2160 (9.61) 1692 (7.52) 83205-3/4 x'L' 3/4"-10 3" (76.2) 3230 (14.37) 2530 (11,25) B3205-7/8 x'1' 7/8"-9 31/2" (88.9) 4480 (19.93) 3508 (15.60) B3205-1 x'L' 1"-8 4" (101.6) 5900 (26.24) 4620 (20.55) B3205-11/ex'L' 11/8"-7 41/2" (114.3) 7450 (33.14) 5830 (25.93) • B3205-11/4 x'L' 11/4"-7 5" (127.0) 9500 (42.25) 7440 (33.09) B3205-11/2 x'L' 11/2"-6 6" (152.4) 13800 (61.38) 10807 (48.07) B3205-13/4 x'L' 13/4"-5 7" (177.8) 18600 (82.73) 14566 (64.79) B3205-2 x'L' 2"-41/2 8" (203.2) 24600 (109.42) 19625 (87.29) 83205-21/4 x'L' 21/4"-41/2 9" (228.6) 32300 (143.67) 25295 (112.51) B3205-21/2 x'1' 21/2"-4 10" (254.0) 39800 (177.03) 31169 (138.64) 83205-23/4 x'1' 23/4"-4 11" (279.4) 49400 (219.73) 38687 (172.08) B3205-3 x'L' 3"-4 12" (304.8) 60100 (267.32) 47066 (209.35) ATR - All Threaded Rod 120" (3.05m) Lengths (TOLCO Fig. 100) Fig. 99 - All Threaded Rod Cut To Length u� o s Size Range: 3/8"-16 thru 11/2"-6 rod in 120" (3.05m)lengths or cut to length a ,\11�a�1`` Material: Steel ����� y Maximum Temperature: 750°F(399°C) a� `o 0 0 Finish: Plain. Contact B-Line for alternative finishes and materials. i m d Order By: Part number, rod diameter and finish H a 4 Part No.-Size x Length Threads Recommended Load Approx.WtJ100 Ft. ATR Fig.99 Per Inch Lbs. (kN) Lbs. (kg) ATR 1/4"x 120 99-1/4"x length 20 240 (1.07) 12 (5.44) ATR 3/8"x 120 99-3/8"x length 16 730 (3.24) 29 (13.15) ATR 1/2"x 120 99-1/2"x length 13 1350 (6.00) 53 (24.04) ATR 5/8"x 120 99-5/9"x length 11 2160 (9.60) 89 (40.37) ATR 3/4"x 120 99-3/4"x length 10 3230 (14.37) 123 (55.79) . ATR 7/a"x 120 99-7/s"x length 9 4480 (19.93) 170 (77.11) ATR 1"x 120 99-1"x length 8 5900 (26.24) 225 (102.06) NI dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. B-Line Pipe Hangers&Supports 236 Revised 4/28/2014 by IFA•N VERTICAL MOUNT SAMMYS". SAMMYS® for Wood Not less than Wood Flooring 2"nominal width Product Features 4_40-1/21 niTWood •No pre-drilling required. Not less than ••Quick to install using the Sammy 3"nominal Nut Driver with an 18V cordless thickness(2-1/2') (depth or side drilVdriver, of vertical m ember) .1 •Saves time from traditional methods. For vertical use- twill In center of lower face. •Reduces installation cost. ' ' ^ MiNmum 2"embedment Into baMe' , _ l material for NFPA 13 compliance. Composite t Truss •Made in the U.S.A. ) Consult truss mansfacturer for recommercec installation pit. I r^"- Pre,ldfing may oe required fo GST .� 25-380.Tod avadahle on page 10. k 11 ii I Approvals Rod Part Model Screw Ultimate UL Test FM Test Box Case i Size Number Descriptions Pullout(Ibs) Load(Ibs) Load(Ibs) Qty Qty _ 1/4" 8002957 GST 100 1/4 x 1' 210 (7116'OSB) 25 125 670(314"Ply) 1,4" 8003957 GST 200 1,4 x 2' 1760(Fir) 25 125 1/4" 6004957 GST 300 1/4 x3" 2060(Fir) 25 125 3i8" 8006957 GST.75 1;4 x 314' 564 (3`4"Ply) 25 125 318' 8007957 GST 10 114 x 1' 210(7116'OSB) 300 25 125 1I 670(314'Ply) — ii Q-' . 3 8" 8008957 GST 20 1.4 x 2" 1760(Fir) 850 1475 25 125 318" 8068925 GST 20 SS 114x2" 1760(Fir) 850 25 125 3/8" 8009925 GST 25-380 318 x 2-1/2" 2113(Fir) 1500 25 125 4 3/8" 8010957 GST 30 1/4 x 3" 2060(Fir) 1500 1475 25 125 #14 Black Nut Diver 3'8" 8069925 GST 30-SS 1/4 x 3" 2060(Fir) 25 125 Part.8113910 3/8" 8011925 GST 40 114x 4' 2180(Fir) 25 125 3/8" 8012925 GST 60 1/4 x 6" 2230 (Fir) 25 125 Ohm 1/2" 8013925 GST 2 1/4 x 2" 1760(Fir) .1k 25 125 112" 8014925 GST 2.5-380 318 x 2-1/2" 2113 (Fir) 25 125 112' 8015925 GST 3 114 x 3' 2275(Fr) 25 125 :ti 1/2' 8016925 GST 4 1/4 x 4" 2180(Fir) 25 125 172' 8017925 GST 6 114 x 6' 2230(Fir) 25 125 :a #14 SW Red �` " Nut Driver ti•. ��� Part#8114910 SAMMYSwivel Head® for Wood .,t:.i.:p:„ �LI;iA.J L/ al 1C1 S,iriv, UP L. • '/1; ••••Y.� U .ottL,�t�rr.: Product Features •Eliminates distortion of threaded rod. •Saves time from traditional methods. 114 •Accommodates up to 3''/z'x 12 pitch roof. •Reduces installation cost. I •Allows 17°deflection from vertical. •Made in the U.S.A. 0 111* Rod Part Screw Ultimate UL Test FM Test Min Box Case Approvals Size Number Model Descriptions Pullout(Ibs) Load(Ibs) Load(Ibs) Thickness Qty Qty 4x•¢ 318" 8139957 SH-GST 20 1/4x2' 1257(Fir) 1050 1475 25 125 125 0 -' 318" 8141957 SH-GST 30 1/4 x 3" 1720(Fir) 1500 1475 25 125 #14 Black Nut Driver SPECIAL NUT DRIVER SYSTEM:The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time.When the face of the driver comes into Part#8113910 contact with the material you are installing into,continue drilling until nut driver spins free.Installation is then complete.Warranty requires the use of the appropriate nut driver for installations. For the most up to date information,visit www.sammysuperscrew.com 4 :!; c)iS