Loading...
Permit (107) CITY OF TIGARDidalier..mil MECHANICAL PERMIT :I 41 s COMMUNITY DEVELOPMENT Permit#: MEC2016-00156 TIGARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 03/14/2016 Parcel: 2S110AA00900 Jurisdiction: Tigard Site address: 14050 SW PACIFIC HWY 101 Project: Genius Accountant Inc. Subdivision: None Lot: None Project Description: Replacing existing fan coil,condenser,duct work,and controls. 3/30/16,REPRINTED to correct suite address to 101. Contractor: ADVANCED HEATING&AIR CONDITIONING INC Owner: ELLINGSON REVOCABLE INTERVIVOS T 5825 SE FOSTER RD BY ELLINGSON, JOSEPH M&JEAN E TRS PORTLAND, OR 97206 420 W LASSEN AVE CHICO, CA 95973 PHONE: 503-774-0161 PHONE: FAX: 503-774-4391 FEES Specifics: Description Date Amount Type of Use: COM Permit Fee 03/14/2016 $431.53 Class of Work: ALT Type of Const: Plan Review 03/14/2016 $107.88 Occupancy Grp: Occupancy Load: 12%State Surcharge-Mechanical 03/14/2016 $51.78 Stories: Info Process/Archiving-Sm$0.50(up to 03/14/2016 $1.00 11x17) Project Valuation: $13,250.00 Fuel Air Handlers Fuel Types: Units< 10000 cfm: Gas Pressure: Units>10000 cfm: Furnaces Boilers&Compressors Furnaces< 100K BTU: 0-3 HP: Furnaces>= 100K BTU: 3-15 HP: Floor Furnaces: 15-30 HP: Unit Heaters: 30-50 HP: Vents w/o Appliances: 50 or Greater HP: Air Conditioning: 1 Heat Pump: Appliances Vent Fans: Vent Systems: Total $592.19 Hoods: Comm Incinerators: Woodstoves: Gas Fireplaces: Required Items and Reports(Conditions) Clothes Dryers: Other Mech Units: Gas Outlets: Other Desc: Fan coils Duct Work: 1 Fire/Smoke Dampers: This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a copy of the rules or direct questi.._ : •UNC by calling 503.232.1987 or 1.800.332.2344. t . ...., Issued By Permittee Signature: , Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. CITY OF TIGARD MECHANICAL PERMIT s . COMMUNITY DEVELOPMENT Permit#: MEC2016-00156 TIGARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 03/14/2016 Parcel: 2S 110AA00900 Jurisdiction: Tigard Site address: 14050 SW PACIFIC HWY 104 Project: Genius Accountant Inc. Subdivision: None Lot: None Project Description: Replacing existing fan coil,condenser,duct work,and controls for suites 104 and 105. Contractor: ADVANCED HEATING&AIR CONDITIONING INC Owner: ELLINGSON REVOCABLE INTERVIVOS T 5825 SE FOSTER RD BY ELLINGSON, JOSEPH M &JEAN E TRS PORTLAND, OR 97206 420 W LASSEN AVE CHICO, CA 95973 PHONE: 503-774-0161 PHONE: FAX: 503-774-4391 FEES Specifics: Description Date Amount Type of Use: COM Permit Fee 03/14/2016 $431.53 Class of Work: ALT Type of Const: Plan Review 03/14/2016 $107.88 Occupancy Grp: Occupancy Load: 12%State Surcharge-Mechanical 03/14/2016 $51.78 Stories: Info Process/Archiving-Sm$0.50(up to 03/14/2016 $1.00 11x17) Project Valuation: $13,250.00 Fuel Air Handlers Fuel Types: Units< 10000 cfm: Gas Pressure: Units> 10000 cfm: Furnaces Boilers&Compressors Furnaces<100K BTU: 0-3 HP: Furnaces>= 100K BTU: 3-15 HP: Floor Furnaces: 15-30 HP: Unit Heaters: 30-50 HP: Vents w/o Appliances: 50 or Greater HP: Air Conditioning: 1 Heat Pump: Appliances Vent Fans: Vent Systems: Total $592.19 Hoods: Comm Incinerators: Woodstoves: Gas Fireplaces: Required Items and Reports(Conditions) Clothes Dryers: Other Mech Units: Gas Outlets: Other Desc: Fan coils Duct Work: 1 Fire/Smoke Dampers: This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a copy of the rules or direct questions to OUNC by calling 503.232.1987 or 1.800.332.2344. Issued By: •• mittee Signature: Call 503.6 •.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. Mechanical Permit APPliR FOR OFFICE USE ONl,v Cl of Tigard � �� Received `, g Date/By: 4e , .4• 1 No.:Aa, • --, _ U510,q ' 13125 SW Hall Blvd.,Tigard,OR 97223 Plan Review p Phone: 503.718.2439 Fax: 503.591M0 7 ?n 1 Date/By Other Permit. TI G A R D Inspection Line: 503.639.4175 Date Ready/By: ® See Page 2 for Internet: www.tigard-or.gov , , Notified/Method: ' Supplemental Information d x t�V SI COMMERCIAL.Fk)E'sCI(EDU l = >)aE.Or3EGK 1--`., Mechanical permit fees*are based on the value of the work ❑New construction ®Addition/alteration/replacement performed. Indicate the value(rounded to the nearest dollar)of all 0 Demolition 0 Other: mechanical materials,equipment,labor,overhead,and pr oft. Value:$ 13Sn AY;_ CEGOR .,OF,GO,NS RICTQN CES!E Q ME / S1EM$FEES* , ❑ I-and 2-family dwelling [I Commercial/industrial ❑Accessory building For special information use checklist. ❑Multi-family 0 Master builder 0 Other: Description Qty. Ea. Total ;-, :N..4.6.14.-:=SITE'INFORMATION,�AND LOCATION Heating/cooling: 1`/ 0 s Air conditioning 46.75 Job site address: / t //h� � y �u 1"��- �/W Furnace 100,000 BTU(ducts/vents) 46.75 _ City/State/ZIP: 1'6 (911,.( ©/Z ? 7 2- 7 Furnace 100,000+BTU(ducts/vents) 54.91 �JHeat pump V61.06 Suite/bldg./apt.no.: 1644 ILS Project name: r.& C' l r c,, Duct work ✓ 23.32 Cross street/directions to job site: Hydronic hot water system 23.32 Residential boiler(radiator or hydronic) 23.32 Unit heaters(fuel-type,not electric), in-wall,in-duct,suspended,etc. 46.75 Flue/vent for any of above 23.32 Subdivision: Lot no.: Other: 23.32 Other fuel appliances: Tax map/parcel no.: Water heater 23.32 � = DESCRIPTION-20F WORK' Gas fireplace/insert 33.39 / Flue/� Flue vent for water heater or gas ffr 1a(.c.. i57i11/ et -`a rtCc1I1 Loetc(er1,SC3C/'I fireplace 23.32 ( ti C-4 Q..k c ^r C n—ri1c Ic, L' lc -c U� fI ;