Plans BUP2012 - 00130 RECEIVED JUL 0 3 2012 MILDREN DESIGN GROUP, P.C. ARCHITECTURE ■ SPACE PLANNING effyoFTIGARD 7650 S.W. Beveland, Suite 120 PlumbingRequirements General Notes �uII�11�C3DIVISION Tigard; Oregon 97223-8692 Code Analysis (503) 244-0552 BASED ON THE 2010 OREGON STRUCTURAL AND SPECIALTY CODE PER TABLE 29—A A. VERIFY AND CONFIRM ALL DIMENSIONS AND CONDITIONS. B OCCUPANCY 1:200, 4589 SF = 23 OCC = 11.5 MALE, NOTIFY ARCHITECT OF ANY DISCREPANCIES PRIOR TO START OCCUPANCY AND CONSTRUCTION 11.5 FEMALE OF WORK. ASSUMED OCCUPANCY: B B. ALL HARDWARE IN ACCORDANCE WITH ANSI 117.1. NON—SEPARATED USE BETWEEN: N/A REQUIRED PROVIDED (ON FLOOR) C. PROVIDE (1) APPROVED FIRE EXTINGUISHER WITH RATING OF CONSTRUCTION TYPE: III—B LAVATORIES 1 MALE, 1 FEMALE 2 MALE, 2 FEMALE NOT LESS THAN 2—A: 10B FOR EACH 3,000 SQ.FT. OF FLOOR WATER CLOSETS 1 MALE, 1 FEMALE 2 MALE, 3 FEMALE AREA TRAVEL FROM ANY PORTION OF BUILDING NOT TO EXCEED 75'. FIRE EXTINGUISHERS NEED TO BE NEAR EACH FIRE-RESISTANCE RATING REQUIREMENTS REQUIRED EXIT AND EVERY SEVENTY FIVE FEET ALONG THE STRUCTURAL FRAME: 0 HRS. PATH OF EGRESS. EXTERIOR BEARING WALLS: 2 HRS. D. SPRINKLERS ARE EXISTING; A SEPARATE PERMIT WILL BE REQUIRED EXTERIOR NON-BEARING WALLS: 0 HRS. FOR ANY CHANGES (SEE "DEFERRED SUBMITTALS"). INTERIOR NON-BEARING WALLS: 0 HRS. Deferred Submittals E. ALL FINISHES (IE BASE, ETC.) TO MATCH EXISTING UNLESS FLOOR CONSTRUCTION: 0 HRS. PLUMBING NOTED OTHERWISE. HVAC F. PROVIDE 20 CFM OF OUTSIDE AIR PER OCCUPANT AT FIRE PROTECTION: BUILDING IS EQUIPPED WITH AN AUTOMATIC FIRE PROTECTION SYSTEM AND AUTOMATIC SMOKE ELECTRICAL OFFICE AREA. LEVEL 4 FINISHED WALLS (NEW) TO RECEIVE (1) COAT PRIMER, DETECTION THROUGHOUT IN ACCORDANCE WITH OSSC 903.3.1.1 SPRINKLERS G. VERTICAL EXITS AND PASSAGWAYS EXIT CORRIDORS AND EXITWAYS ROOMS AND ENCLOSED SPACES (2) COATS ACRYLIC LATEX. FLAME SPREAD INDEX: CLASS C: 76 - 200 CLASS B: 26 - 75 CLASS C: 76 - 200 H. SUSPENDED CEILING IS EXISTING; CONFORMS TO OSSC RULING SMOKE DEVELOPED INDEX: CLASS C: 0 — 450 CLASS B: 0 — 450 CLASS C. 0 — 450 FOR 2004 OSSC SECTION 1621.1 AND 2007 OSSC (EFFECTIVE APRIL 1, 2007) SECTION 1613.1, DATED APRIL 20, 2007. 4505 EXITING: 1. VERIFY POWER AND DATA REQUIREMENTS WITH OWNER ;OIEL A. VA UEZ B OCCUPANCY: COMMON PATH OF EGRESS TRAVEL DISTANCE DOES NOT EXCEED 100'-0" PER OSSC SECTION 1014.3 AND TENANT. Gol EXIT ACCESS TRAVEL DISTANCE DOES NOT EXCEED 300'-0" PER OSSC SECTION 1016.1 J. FURNISH THREE SILENCERS FOR SINGLE ACTING SINGLE DOORS. ' K. DIMENSIONS THAT ARE NOT MARKED MINIMUM OR MAXIMUM ARE ABSOLUTE DIMENSIONS. OF O L. DO NOT PLACE OPPOSING ELECTRICAL OR DATA MUDRINGS WITHIN SAME CAVITY. M. CONTRACTOR TO INSTALL CEILING TILES WITHIN EXISTING CEILING Owner: GRID (TILES STORED ON SITE) AND RELOCATE LIGHTS, DIFFUSERS, ETC. AS REQUIRED FOR NEW LAYOUT. Pacific NW N. ALL ELECTRICAL SWITCHING TO TIE INTO EXISTING BUILDING SWEEP SYSTEM (SWITCHING ORIGINALLY INSTALLED BY Properties CAPITOL ELECTRIC). p 0. PROVIDE SOUND ATTENUATION BATT AT ALL NEW INTERIOR WALLS. P. PROVIDE PAINT AT NEW WALL LOCATIONS AND WHERE IDENTIFIED BY KEYNOTE. Q. CONTRACTOR TO REUSE EXISTING DOORS AND DOORS STORED ON SITE WHERE POSSIBLE OR NEW DOORS WHEN NECESSARY. 6600 S.W. 105th Avenue R. CONTRACTOR TO USE CARPET TILE STORED ON SITE AS REQUIRED. Beaverton, Oregon 97005 Project~ Broad River Expansion Project 11850 SW 67th Ave-Suite 140 Tigard, Oregon 97223 �� Sheet Title: Exist m / Building ��� ' ;\ Area of Work Cover Sheet 11ilu O 4 CITY OF TIGARD O Approved..........C.1.................[ �� Revisions: Conditionally Approved..............[ ] / See Letter to:Follow..................[ ] Attached................ ] Permit Number, ot Address: r5 � Date: Approved plans shall be on jots site. 0-T-C RIdCmIf MILDREN DESIGN GROUP, P.C., 2012, ALL $newco& RIGHTS RESERVED AccessibUlty THESE DRAWINGS ARE THE PROPERTY OF(// /� MILDREN DESIGN GROUP, OAND ARE !!! C l NOT TO BE USED OR REPRODUCED IN ANY MANNER, EXCEPT WITH THE PRIOR WRITTEN OFFICECOPY PERMISSION OF MILDREN DESIGN GROUP, P.C. Key Plan Date: 3 July 2012 No Scale Drawn by: Checked by: BK DAV Job Number. 110192 Sheet Permit Submittal - July 2012 AO Keynotes 1. EXISTING WALL AND DOOR TO BE REMOVED TYPICAL 2. PROVIDE ALTERNATE PRICE TO REMOVE EXISTING WALLS, . CLOSET DOORS AND CASEWORK THIS SUITE MILDREN DESIGN GROUP, P.C. 114 3. CENTERLINE WALL/CENTERLINE MULLION TYPICAL % 4. NEW WALL FLUSH WITH EXISTING FURRING ARCHITECTURE ■ SPACE PLANNING X4 8 XXX 5. RELOCATED EXISTING FIRE EXTINGUISHER FROM DEMOLISHED 23.13 S.F. � � 7650 S.W. Beveland, Suite 120 /100 = 1 % WALL TO THIS LOCATION Tigard, Oregon 97223-8692 B:EXI TS 1 % %o (503) 244-0552 / 4 / OFFICE / 102 102 % X4 B XXX VESTIBULE 222.7 S.F. '/ X4 01 XXX /100 = 3 100.73 S.F. B:EXITS 1 Wall Legend E /100 – �" EXIT 0FI 104 ® 112 EXISTING WALL TO REMAIN X413 XXX 1 MACHINE RM. `I \ 125.54 S.F. C - - _ _ _ EXISTING WALL TO BE REMOVED J E 103 OFFICE /100ITS 1 113 FFICE 3%" METAL STUDS WITH % " GYPSUM 113 111 I X4 B X XX BOARD '\ X4 B X XX �`� 185.29 S.F. 125.54 S.F. WOMEN d TRAINING \ /100 = 2 112 /100 = 2 O -10-4T- ��' B:EXITS 1 DW X4 B X XX 104, B:EXITS 1 MEN 405.77 S.F. --- • /20 = 21110 OFFICE o E B:EXITS 1 � ��-, NC) 109 X4 B XXX p�°c °` 126.62 S.F. , Room Symbol Le end 4505 1 FE 'ti \ O 10Q = 2 °' J L .A. VA EZ / OPEN OFFICE B:EXITS 1 ROOM NAME GON 103 X4 B X XX 5 ����� OFFICE ROOM NUMBER 790.78 S.F. �ti ROOM AREA LOAD 44B�R O/100 = 8 1 .] / ROOM FINISH B:EXITS 1 .-�'. joFACTOR B9 107 XXX/100: 2-�_NUMBER OF 11aI�. 108 OFFICE \'j. B: 2 E ITS OCCUPANTS Str X408 X XX � � NUMBER OF Owner: 129.71 S.F. ��, OCCUPANCY GROUP PER EXITS PROVIDED Pacific NW/100 = 2 IBC TABLE 1004.1.2/NUMBER " '�GoMM 106 B:EXITS 1 3 105 , OFFICE Properties 109 q X4 B X XX � � \ ,C _ 2 2 127.5 S.F. -`. . r A2 /100 = 2 B:EXITS 1 Finish Schedule 3 ROOM NAME 6600 S.W. 105th Avenue OFFICE FIOOr Flnlsh — A4BB9 Beaverton, Oregon 97005 107 ,. X4 B X XX A. EXPOSED CONCRETE SLAB 132.95 S.F. B. CARPET �2 OFFICE /100 = 2 C. SHEET VINYL Project: 106 B:EXITS 1 D. VINYL COMPOSITION TILE OFFICE X4 B X XX E. SLATE TILE Broad River 105 132.32 S.F. /100 = 2 X. EXISTING TO REMAIN X4 B X XX B:EXITS 1 134.27 S.F. Base Expansion /100 = 2 B:EXITS 1 0. NO BASE Project 4. 4" RUBBER BASE X. EXISTING TO REMAIN Wail Finish A. EXPOSED CONCRETE 11850 SW 67th Ave-Suite 140 B. GYPSUM BOARD AND PAINT Tigard, Oregon 97223 C. 4' PLASTIC WAINSCOT WITH STAINLESS STEEL TRIM AT EDGES, W.R. GYPSUM BOARD AND PAINT ABOVE. TYPICAL AT ELEVATED WALLS ONLY. Sheet Title- FloorFloor I lan X. EXISTING TO REMAIN Floor Plan 4,589 SF OFFICE CeilingFinish 0 2 4 8 16 46 TOTAL OCCUPANTS A. EXPOSED ROOF STRUCTURE B. SUSPENDED ACOUSTICAL - TEE BAR C. GYPSUM BOARD AND PAINT Door Schedule Door Types X. EXISTING TO REMAIN Celhng height MARK NOMINAL SIZE FRAME DOOR HARDWARE REMARKS 8 8'-0" WIDTH HEIGHT THICK. MAT'L FINISH MAT'L FINISH TYPE GROUP 9. 9'-0" 102 3'-0" 8'-0" 1-3/4" MTL FF Sc ST B 1 12. 12'-0" 103 3'-0" 8'-0" 1-3/4" MTL FF SC ST B 2 104A 3'-0" 8'-0" 1-3/4" MTL FF SC ST B 3 X. EXISTING TO REMAIN 10413 3'-0" 8'-0" 1-3/4" MTL FF SC ST B 2 Revisions: 105 3'-0" 8'-0" 1-3/4" MTL I FF Sc ST A 1 106 3'-0" 8'-0" 1-3/4" MTL FF SC ST A 1 107 3'-0" 8'-0" 1-3/4" MTL FF Sc ST A 1 \ \ 108 3'-0" 8'-0" 1-3/4" MTL FF SC ST A . 1 109 3'-0" 8'-0" 1-3/4" MTL FF SC ST A 1 N Legend 110 3'-0" 8'-0" 1-3/4" MTL FF SC ST A 1 111 3'-0" 8'-0" 1-3/4" MTL FF SC ST A 1 3'X8' TEMPERED REtIrE FIRE EXTINGUISHER 112 3'-0" 8'-0" 11-3/4"1 MTL FF SC ST A 1 113 3'-0" 8'-0" 1-3/4" MTL FF SC ST B 1 A B loo NEW DOOR LEGEND Door Hardware EXISTING DOOR TO REMAIN CL CLEAR FF FACTORY FINISH GROUP 1 GL GLASS 2 PAIR BUTTS STANLEY 652 FBB179 4/2 X 4Y MILDREN DESIGN GROUP, P.c., zoiz, ALL 1 1 RIGHTS RESERVED SC SOLID CORE 1 LOCKSET SCHLAGE 626 SPARTA ND50PD THESE DRAWINGS ARE THE PROPERTY OF ST STAIN MILD1 STOP IVES 630 407Y NOT TO BE UEN SED GN GORU REPRODUCED AND IN ANY MANNER, EXCEPT WITH THE PRIOR WRITTEN PERMISSION OF MILDREN DESIGN GROUP, P.C. GROUP 2 2 PAIR BUTTS STANLEY 652 FBB179 4% X 4% Date: 3 July 2012 1 LATCHSET SCHLAGE 626 SPARTA NDI OS Drawn by: Checked by: 1 CLOSER LCN 4041 1 STOP IVES 630 407% BK DAV GROUP 3 Job Number: 110192 2 PAIR BUTTS STANLEY 652 FBB179 4% X 4% Sheet 1 LOCKSET SCHLAGE 626 SPARTA ND70PD 1 CLOSER LCN 4041 1 STOP IVES 630 407, Permit Submittal - Jul 2012 Al v Electrical Symbols Keynotes 1. EXISTING SUSPENDED CEILING AND LIGHTS EXISTING FLUORESCENT LIGHT FIXTURE 2. EXISTING CEILING OUTLET3. REPAIR GRID AS REQUIRED WHERE BROKEN AT REMOVED WALLS; PROVIDE NEW CEILING TILE AS NEEDED - SHOWN MILDREN DESIGN GROUP, P.C. EXISTING FLUORESCENT LIGHT FIXTURE TO BE REMOVED OR RELOCATED SHADED ARCHITECTURE ■ SPACE PLANNING 4. REMOVE EXISTING WALL MOUNTED CARD READER AND/OR 7650 S.W. Beveland, Suite 120 RELOCATED EXISTING FLUORESCENT LIGHT FIXTURE KEY PAD, REPLACE WITH BLANK COVER PLATE (STYLE AND Tigard, Oregon 97223-8692 COLOR TO BE SELECTED BY OWNER) (503) 244-0552 EXISTING EXIT SIGN ON BATTERY BACKUP TO REMAIN NEW LIGHT SWITCH, MATCH EXISTING COVERPLATE COLOR N NEW 3-WAY LIGHT SWITCH, MATCH EXISTING COVERPLATE N 3 COLOR " @= EXISTING DUPLEX OUTLET W EXISTING QUADPLEX OUTLET N A EXISTING DATA OULET D EXISTING DUPLEX AND DATA FLOOR OUTLETS EXISTING DUPLEX OUTLET TO BE REMOVED EXISTING QUADPLEX OUTLET TO BE REMOVED . EXISTING DATA OUTLET TO BE REMOVED 1 �N NEW DUPLEX OUTLET C� 00- DN NEW DATA OUTLET WITH PULL STRING 4505 > 0, 0 GON 3 OF Owner: Pacific NW Properties 3 6600 S.W. 105th Avenue Beaverton, Oregon 97005 Reflected Ceiling Plan Project: 0 2 4 8 16 Broad River 0 Expansion Project V a. i� VPX6 11850 SW 67th Ave-Suite 140 Tigard, Oregon 97223 I 4 X6 WHERE TOP OF WALL TO STRUCTURE (1) 20 GA. 35/8" NOMINAL METAL Sheet Title: o 2 ABOVE IS LESS THAN 5'-9" PROVIDE STUD BRACING TO STRUCTURE Ref lected o (1) BRACE AT 8'-0" O/C TO ONE WITH (2) #8 SHEET METAL IN SIDE ONLY, STAGGER SIDES. WHERE SCREWS AT EACH END; PROVIDE Ceiling Plan DOUBLE STUD BRACE WHEN MULLION px6 DISTANCE IS GREATER THAN 5'-9", DISTANCE TO STRUCTURE ABOVE " Details PROVIDE BRACES EACH DIRECTION AT and Details IS GREATER THAN 5 -9". BRACING �px6 x. 450 8'-0" 0/C TO BE PROVIDED WHERE DISTANCE BETWEEN PERPENDICULAR px6 INTERSECTING WALLS OR HORIZONTAL BRACING BETWEEN '4 WALLS EXCEEDS 8'-0" (DO NOT SEALANT TAPE EXTEND BRACING INTO EXPOSED 2 STRUCTURE AREAS) Revisions: qP px 6 L 1 Y2" x 912" x 16 GA x �x6 (3J dr 3" WITH� (/4 1[8 SCREWS(3)dr l � Yt SUSPENDED CEILING Mir ALUMINUM BRAKE SHAPE EACH SIDE TO MATCH EXISTING SYSTEM ATTACH STUD TRACK CASING BEAD USG 200-A �px6 (3)dr TO BRACING THROUGH 5/8" GYPSUM BOARD EACH SIDE OVERSIZED HOLE IN SECURE TO STUDS WITH TYPE 'S' INTERIOR OFFICE WALL GRID SCREWS AT 5" - 7" 0/C 3Y2" SOUND 24" 0/C STUD CHART: ATTENUATION BATT •362 S 125-18 TO 9'-11" • 362 S 137-33 TO 17'-6" • 400 S 162-33 TO 19'-10" 4" RUBBER BASE •600 S 162-33 TO 27'-7" TYPICAL SEE A/E FOR ALTERNATE SIZES MILDREN DESIGN GROUP, P.C., 2012, ALL X4 POWER-ACTUATED FASTENERS: RIGHTS RESERVED xaTHESE AWINGS ARE TE POPERTY • 0.145" 0 x %" MIN. EMBED MILDREN DDESIGN GROUPHP.CR AND AREF X4 AT 12" 0/C, WALL TO 22'-0" NOT TO BE USED OR REPRODUCED IN ANY 0.145" X " MIN. EMBED MANNER,PERMISSION OF MILDREN DESIGN GROUEXCEPT WITH THE PRIOR P, P.C.. AT 6" 0/C, WALL TALLER THAN 22'-0" Date: 3 July 2012 ('1 Wall to Suspended Ceiling2 Wall at Mullion Drawn by: Checked by: ��23'=1'-0" A2 3"=1'-0" BK DAV 1a1d-r8 1i1b Power Plan Job Number: 110192 Sheet 0 2 4, 8 16 Permit Submittal - July 2012 A2