Loading...
Report (67) HN Series Effective November 2016 HS Series Technical Data TD45O049EN Supersedes October 2014 ST Series Exceder Strobe, Horn Strobe, and Horn Notification Appliances Description , _ , The Wheelock Exceder Series of notification appliances feature a sleek modern design that will please building owners " with reduced total cost of ownership. Installers will benefit from its comprehensive feature list, including the most candela options }iirrin one appliance, low current draw, no tools needed for setting changes, voltage test points, 12/24 VDC operation, universal mounting base and multiple mounting options for both new and retrofit construction. The Wheelock Exceder Series incorporates high reliability and high _ 7` FIRE I p C efficiency optics to minimize current draw allowing for a greater (1 l_ number of appliances on the notification appliance circuit.All strobe models feature an industry first of 8 candela settings on a single appliance. Models with an audible feature 3 sound settings (90, 95, 99 dB).All switches to change settings, can be set without the use ti of a tool and are located behind the appliance to prevent tampering. r' te Wall models feature voltage test points to take readings with a \ voltage meter for troubleshooting and AHJ inspection. = The Wheelock Exceder Series of wall and ceiling notification I I,, appliances feature a Universal Mounting Base (UMB)designed to simplify the installation and testing of horns,strobes,and combination horn strobes.The separate universal mounting base ! can be pre-wired to allow full testing of circuit wiring before the appliance is installed and the surface is finished. It comes complete with a Contact Cover for protection against dirt, dust, paint and l' damage to the contacts.The Contact Cover also acts as a ' shunting device to allow pre-wire testing for common wiring issues. The Contact Cover is polarized to prevent it from being installed '< i incorrectly and prevents the appliance from being installed while it is on the UMB. When the Contact Cover is removed the circuit will show an open until the appliance is installed.The UMB allows for consistent installation and easy replacement of appliances if required.Wall models provide an optional locking screw for extra secure installation, while the ceiling models provide a captivated screw to prevent the screw from falling during installation. 1 Er ,TN Powering Business Worldwide Technical Data TD450049EN HN Series Effective November 2016 HS Series ST Series Features • Environmentally friendly • Sleek modern aesthetics • Low current draw • Finger slide switches • Up to 9 models now in 1 appliance draw® • Voltage test points • 12/24VDC on a single appliance • Multiple voltages • Easy to remember model numbers • 3 Audible settings O Patented • 90, 95, 99 dB Note: Please read these specifications and associated installation instruc- tions,before using,specifying,or installing this product.Visit Eaton.com/ • Industry leading-8 candela settings on 1 device massnotification for current installation instructions. • Wall: 15/1575/30/75/95/110/135/185 General Notes • Ceiling: 15/30/60/75/95/115/150/177 • Strobes are designed to flash at 1 flash per second minimum over their"Regulated Voltage Range" • All candela ratings represent minimum effective strobe intensity based on UL Standard 1971. • Series Exceder Strobe products are Listed under UL Standards 1971 and 464 for indoor use with a temperature range of 32°F to 120°F (0°C to 49°C) and maximum humidity of 93% (± 2%) UL 464(85% UL 1971). • Series Exceder horns are under UL Standard 464 for audible signal appliances (Indoor use only). Compatibility and requirements • Synchronize using the Wheelock®Sync Modules or panels with built-in Wheelock®Patented Sync Protocol • Compatible with UL"Regulated Voltage" using filtered VDC or • Universal mouting base unfiltered VRMS input voltage • Ceiling and wall • Strobes produce 1 flash per second over the "Regulated • Mounts to 5 backbox types: 1 gang, 2 gang,4" square, Voltage" range 3.5" octal. &4" octal. (100mm for international customers) Universal mounting base Contact cover Compliance • UL 1971, UL 464, ULC, CSFM, FM 4a ,4P—t'''' �., • ADA/NFPA/ANSI/OSHA . •-ate- t4 v. • RoHS li1 �IJIilk f,: Common base for wall and ceiling with 5 mounting options • Voltage test points for quick troubleshooting and easy spot checking (wall models only) , , ,, . . tl.U C) 2 EATON www.eaton.com HN Series Technical Data TD450049EN HS Series Effective November 2016 ST Series Table 1. Strobe Ratings per UL Standard 1971 UL Max Current® 24 VDC/24 FWR 12 VDC Regulated Voltage Model Range VDC 15 15/75 30 60 75 95 110 115 136 150 177 185 15 15/75 ST 8.0-33.0 0.057 0.070 0.085 - 0.135 0.163 0.182 - 0.205 - - 0.253 0.110 0,140 ►STC 8.0-33.0 0.061 - 0.085 0.103 0.135 0.163 - 0.182 - 0.205 0.253 - 0.110 - Table 2. Horn Strobe Ratings per UL 1971 &Anechoic at 24 VDC UL Max Current®at Anechoic 99 dBA 24 VDC 12 VDC Regulated Voltage Model Range VDC 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 HS 8.0-33.0 0.082 0.095 0.102 - 0.148 0.176 0.197 - 0.242 - - 0.282 0.125 0.159 HSC 8.0-33.0 0.082 - 0.102 0.141 0.148 0.176 - 0.197 - 0.242 0.282 - 0.125 - UL Max Current®at Anechoic 95 dBA 24 VDC 12 VDC Regulated Voltage Model Range VDC 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 HS 8.0-33.0 0.073 0.083 0.087 - 0.139 0.163 0.186 - 0.230 - - 0.282 0.122 0.153 HSC 8.0-33.0 0.073 - 0.087 0.128 0.139 0.163 - 0.186 - 0.230 0.272 - 0.122 - UL Max Current®at Anechoic 90 dBA 24 VDC 12 VDC Regulated Voltage Model Range VDC 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 HS 8.0-33.0 0.065 0.075 0.084 - 0.136 0.157 0.184 - 0.226 - - 0.267 0.120 0.148 HSC 8.0-33.0 0.065 - 0.084 0.120 0.136 0.157 - 0.184 - 0.226 0.267 - 0.120 - ,®UL max current rating is the maximum RMS current within the listed voltage range(16-33 VDC for 24 VDC units).For strobes the UL max current is usually at the minimum listed voltage(16 VDC for 24 VDC units) For audibles the max current is usually at the maximum listed voltage(33 VDC for 24 VDC units).For unfiltered ratings,see installation instructions. Table 3. Horn Ratings per UL Anechoic Model Legend Regulated Voltage Model Range VDC 99 dB 95 dB 90 dB HN = Horn R = Red HN 16-33.0 0.064 0.044 0.022 ST = Strobe A = Agent Lettering(strobes only) HNC 16-33.0 0.084 0.044 0.022 HS = Horn Strobe AL = Alert Lettering(strobes only) HN 8.0-17.5 0.047 0.026 0.017 C = Ceiling Mount N = No Lettering(strobes only) HNC 8.0-17.5 0.047 0.026 0.017 W = White Example 1:STRC=Strobe,Red,Ceiling Mount Table 4. Specification&Ordering Information Example 2:HSR=Horn Strobe,Red,Wall Mount Sync w/DSM or Example 3:HSW=Horn Strobe,White,Wall Mount Wheelock Power 12/24 Mounting Example 4:STW-AL=Strobe,White,Wall Mount,Alert Lettering Model Strobe Candela Supplies VDC® Options Horn Strobes HSR 15/1575/30/75/95/110/135/185 X X UMB® "` HSW 15/1575/30/75/95/110/135/185 X X UMB® I , : ,, ',... ,. .,.*'--- , HSRC 15/30/60/75/95/115/150/177 X X UMB® / 0. /. --t. HSWC 15/30/60/75/95/115/150/177 X X UMB / Strobes / �, STR 15/1575/30/75/95/110/135/185 X X UMB® / STW 15/1575/30/75/95/110/135/185 X X UMB® \\ � LI. ` -s STRC 15/30/60/75/95/115/150/177 X X UMB® ° /' ,, �? ---, STWC 15/30/60/75/95/115/150/177 X X UMB® ***1?1,\"; Horn HNR X X UMB® HNW X X UMB® HNRC X X UMB® Example: HSR Example: HSWC HNWC X X UMB® ,O 12 VDC models feature 15&15/75 settings OO UMB=Universal Mounting Base EATON www.eaton.com 3 Technical Data TD450049EN HN Series Effective November 2016 HS Series ST Series Architects and Engineers Specifications The notification appliances shall be Wheelock Exceder Series HS Audible Strobe appliances, Series ST Visual Strobe appliances and Series HN Audible appliances or approved equals.The Series HS and ST Strobes shall be listed for UL Standard 1971 (Emergency Devices for the Hearing-Impaired)for Indoor Fire Protection Service.The Series HS and HN Audibles shall be UL Listed under Standard 464(Fire Protective Signaling).All Series shall meet the requirements of FCC Part 15 Class B.All inputs shall be compatible with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP)with the ability to operate from 8 to 33 VDC. Indoor wall models shall incorporate voltage test points for easy voltage inspection. The Series HS Audible Strobe and ST Strobe appliances shall produce a flash rate of one(1)flash per second over the Regulated Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged Lexan®lens.The Series shall be of low current design.Where multi- candela appliances are specified,the strobe intensity shall have 8 field selectable settings at 15, 15/75, 30, 75, 95, 110, 135, 185 candela for wall mount and 15, 30, 60, 75, 95, 115, 150, 177 candela for ceiling mount.The selector switch for selecting the candela shall be tamper resistant.The 15/75 candela strobe shall be specified when 15 candela UL Standard 1971 Listing with 75 candela on-axis is required (e.g., ADA compliance).Appliances with candela settings shall show the candela selection in a visible location at all times when installed. The audible shall have a minimum of three(3) field selectable settings for dBA levels and shall have a choice of continuous or temporal (Code 3)audible outputs. The Series HS Audible Strobe, ST Strobe and Series HN Audible shall incorporate a patented Universal Mounting Base that shall allow mounting to a single-gang, double-gang,4-inch square,3.5-inch octal,4-inch octal or 100mm European type back boxes.Two wire appliance wiring shall be capable of directly connecting to the mounting base. Continuity checking of the entire NAC circuit prior to attaching any notification appliances shall be allowed. Product shall come with Contact Cover to protect contact springs. Removal of an appliance shall result in a supervision fault condition by the Fire Alarm Control Panel (FACP).The mounting base shall be the same base among all horn, strobe, horn strobe, wall and ceiling models.All notification appliances shall be backwards compatible. The Series HS and ST wall models shall have a low profile measuring 5.24" H x 4.58"W x 2.19" D. Series HN wall shall measure 5.24" H x 4.58"W x 1.6" D. The Series HSC and STC shall been round and have a low profile with a diameter of 6.68" x 2.63" D. Series HNC ceiling shall have a diameter of 6.68" x 1.50" D. When synchronization is required, the appliance shall be compatible with Wheelock's DSM Sync Modules,Wheelock Power Supplies or other manufacturer's panels with built-in Wheelock Patented Sync Protocol.The strobes shall not drift out of synchronization at any time during operation. If the sync protocol fails to operate, the strobe shall revert to a non-synchronized flash-rate and still maintain (1)flash per second over its Regulated Voltage Range.The appliance shall also be designed so that the audible signal may be silenced while maintaining strobe activation when used with Wheelock synchronization protocol. Wall Appliances: UL Standard 1971, UL Standard 464, California State Fire Marshal (CSFM), ULC, FM, RoHS Ceiling Appliances: UL Standard 1971, UL Standard 464, California State Fire Marshal (CSFM), ULC, FM, RoHS Note:Due to continuous development of our products,specifications and offerings are subject to change without notice in accordance with Cooper Wheelock Inc.,dba Eaton standard terms and conditions. pI - Member WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY Eaton 1000 Eaton Boulevard Cleveland,OH 44122 United States Eaton.com Eaton Life safety&mass notification solutions 273 Branchport Ave. Long Branch,NJ 07740 Eaton.com/massnotification ©2016 Eaton Er A All Rights Reserved Eaton is a registered trademark. - Printed in USA Publication No.TD450049EN All other trademarks are property Powering Business Worldwide November 2016 of their respective owners. '/%%.Gamewell Cooper-Wheelock INSTRUMENTS CONTROL AS/AH Series by Honeywell Single & Multi-Candela Description AS Series Audible Strobe & AH Series Audible Appliances The 2-wire Cooper-Wheelock AS Series audible/ visual and AH Series audible notification appliances r . offer many features with low current draws. tl Strobe options for wall-mounted models include 15/75 cd or field-selectable Multi-Candela strobes that may be set to 15, 30, 75, or 110 cd. Ceiling mounted models incorporate field-selected Series AS Series AH strobe settings of 15, 30, 75 or 95 cd. Features The audible notification appliances provide a field- selectable choice of either a continuous horn tone or • Approvals include: temporal pattern (per ANSI S3.41) when constant - UL Standard 1971 UL Standard 464 voltage is supplied by the notification appliance cir- New York City(MEA) California State Fire cuit. Each tone has three dBA settings to choose Marshall (CSFM) from. Additionally, the audible tone may be silenced • ADA/NFPA/UFC/ANSI compliant while maintaining strobe activation. • Wall-mounted models are available with field multi- candela settings of 15, 30, 75, or 110 cd models may be synchronized when the models • Ceiling mounted models are available with field select- Allable multi-candela settings of 15, 30, 75, or 95 cd are used in conjunction with the Cooper-Wheelock • Single candela models are available in 15/75 cd SM and DSM Sync Modules. • Weatherproof models are available for outdoor use (ASWP) The synchronization of the continuous horn tone • Selected continuous horn or temporal pattern provides the temporal pattern mandated by NFPA (ANSI 3.41) 72 for fireevacuation e acuatlon slgnaling. This ensures a • Three(3)field dBA settings adjusted to 90, 95, or 99 clearly distinguishable temporal pattern when two or dBA for both tones more audible devices are within hearing distance. If • Silenceable horns and non-silenceable strobes the horn tones are not synchronized, the temporal installed over the same wires patterns may overlap. At the same time, the strobes • Strobes flash once per second over the regulated volt- will also be synchronized. This process is in compli- age range ance with ADA recommendations regarding photo- • 12&24 VDC models with wide UL"regulated voltage sensitive epilepsy and NFPA and UFC standards range"using filtered DC or unfiltered FWR input voltage required when installing two or more visual appli- • Synchronize with SM or DSM synchronization ances within a common field of view. modules • Fast installation with In/Out screw terminals using 12 to Only two wires are required to achieve these se- 18 AWG wires quences of operation. Separate circuits for audible An ISO 9000-2000 Company and visual devices are not necessary. SIGNALING a - U� MEA LISTED APPROVED Approved I I 1971,1638,50 (Indoor Models)254-97-M VoL III PENDING GAMEWELL-FCI 12 Clintonville Road, Northford,CT 06472-Tel: (203)484-7161 -Fax:(203)484-7118 Specifications are for information only,are not intended for installation purposes,and are subject to change without notice.No responsibility is assumed by Gamewetl-FCI for their use. X2008 Gamewell-FCI. All rights reserved. www.gamewell-fci.com 9020-0572 Rev.Cl page 1 of 4 Description (Continued) Table 3: Average Mean Current*Series AH-24R/W&AH-12-R/W*W P(Horn only) Voltage High Medium Low General Notes: 16.0 VDC 0.035 0.020 0.14 24.0 VDC 0.050 0.026 0.017 • Strobes are designed to flash at one flash per second 33.0 VDC 0.089 0.035 0.021 minimum over the Regulated Voltage Range. Note that 8.0 VDC 0.093 0.037 0.080 NFPA-72 (1999) specifies a flash rate of one to two flashes per second and ADA guidelines specify a flash 12.0 VDC 0.108 0.049 0.085 rate of one to three flashes per second. 17.5 VDC 0.128 0.069 0.042 • All candela ratings represent minimum effective strobe intensity based on UL Standard 1971. Table 4:Avereage RM*Current Series AS0241575 • Series AS strobe products are Listed under UL Standard 1971 for indoor use with a temperature range of 32° F to Voltage High Medium Low 120° F (0° C to 49° C) and a maximum humidity of 93% 16.0 VDC 0.130 0.114 0.108 (+/-2%). 24.0 VDC 0.107 0.085 0.075 • Series AH horns are Listed under UL Standard 464 for 33.0 VDC 0.105 0.075 0.060 audible signal appliances(indoor use only). • Series AH-24WP audible appliances are Listed under UL Standard 464 for indoor/outdoor use with a temperature Table 5:dBA Ratings for 12 VDC&24 VDC Series range of-31° F to 150° F AS/AH 12&24 VDC Horns (-35° C to 66° C)and a maximum humidity of 95%. Reverberant dBA Anchoic • "Regulated Voltage Range" is the state-of-the-art technol- per UL 464 @ dBA @ ogy used by UL to identify the voltage range. Prior to this Description Volumn 10 pt. 10 pt. technology, UL used the term, "Listed Voltage Range." Continuous High 91 99 Horn Medium 88 95 Table 1: Ratings per UL 1971 Low 83 90 Input Temporal High 87 99 Voltage Regulated Voltage Strobe Pattern Medium 84 95 Model VDC Range VDC/FW R Candela(cd) Low 79 90 AS-24MCW-FA 24 160-330 15/30/75/110 AS-241575W-FR 24 160-330 15(75 or Axis) Table 6: Average RM S Current*for AS-24 M CCCeil- _ AS-121575W-FR 12 80-175 15(75 or Axis) .ina Modgjs @ each Candela Setting AS-24M C C-FW 24 160-330 15/30/75/95 Average Current with High dBA Setting (99 dBA) AS WP-2475W-FR 24 160-330 75 @-31° F Voltage 15 cd 30 cd 75 cd 95 cd 16.0 VDC _0.105 0.145 0.226 0.314 Table 2: Average RMS Current*fir AS-24 MCW Wall-_. 24.0 VDC 0.097 0.120 0.161 0.202 Models @ each Candela Setting 33.0 VDC 0.101 0.113 0.139 0.168 Average Current with High dBA Setting (99 dBA) Average Current with Medium dBA Setting(95 dBA) Voltage 15 cd 30 cd 75 cd 110 cd 16.0 VDC 0.084 0.126 0.222 0.309 16.0 VDC 0.099 0.135 0.219 0.308 24.0 VDC 0.069 0.094 0.145 0.195 24.0 VDC 0.093 0.114 0.157 0.197 33.0 VDC 0.068 0.083 0.114 0.145 33.0 VDC 0.098 0.108 0.138 0.166 Average Current with Low dBA Setting (90 dBA) Average Current with Medium dBA Setting (95 dBA) 16.0 VDC 0.076 0.121 0.220 0.306 16.0 VDC 0.078 0.116 0.203 0.282 24.0 VDC 0.069 0.084 0.138 0.185 24.0 VDC 0.065 0.088 0.133 0.179 33.0 VDC 0.049 0.068 0.102 0.132 33.0 VDC 0.065 0.078 0.106 0.134 Average Current with Low dBA Setting (90dBA) Table 7: Average Mean Current*Series AS-241575 16.0 VDC 0.070 0.111 0.201 0.279 Voltage High Medium Low 24.0 VDC 0.052 0.077 0.126 0.169 8.0 VDC 0.320 0.276 0.286 33.0 VDC 0.046 0.063 0.063 0.121 12.0 VDC 0.250 0.195 0.175 17.5 VDC 0.205 0.105 0.130 GAMEWELL-FCI 12 Clintonville Road, Northford,CT 06472-Tel: (203)484-7161 -Fax:(203)484-7118 www.gamewell-fci.com 9020-0572 Rev. Cl page 2 of 4 ) SYNC MODULES #SM Sync Module is rated for 3.0 amps @ 24 VDC MODEL ORDER INPUT AVERAGE MEAN ## DSM Sync Module is rated for 3.0 amps per circuit. CODE VOLTAGE(VDC) CURRENT@ 24VDC The maximum number of interconnected SW/2/24-R# 6369 24VDC 0.028A DSM Modules is 20. SM-12124-R## 6374 24VDC 0.035A WIRING DIAGRAMS SERIES AS APPLIANCES NON-SYNCHRONIZED SERIES AS APPLIANCES SYNCHRONIZED WITH SM MODULE SINGLE CLASS"B"NAC FROM TO NEXT CIRCUIT WITH AUDIBLE SILENCE FEATURE PRECEDING + ♦ APPLIANCE SM AORLFACPE I■ OR EOLR F STROBE ® +STROBE NAC WA _STROBE CIRCUIT AS< AS< C AUDIBLE ® +AUDIBLE P NAC EOLR21 CIRCUIT ® -AUDIBLE SERIES AS APPLIANCES SYNCHRONIZED SERIES AS APPLIANCES SYNCHRONIZED WITH DSM MODULE SINGLE CLASS"A" NAC WITH MUTIPLE DSM MODULES CIRCUIT WITH NO AUDIBLE SILENCE FEATURE AUDIBLE DSM NAC DSM#1 STROBE CIRCUIT NAC +SYNC ® STROBE OUTel CIRCUIT NAC +SYNC AS< AS< SYNC CIRCUIT ® _SYNC +OUT 1 AUDIBLE +IN 1 NAC DSM#2 m� mI m4 F CIRCUIT _ I =MINUS 1 A STROBE F NAC +SYNC AS< ASF] ;— +AUDIBLE C CIRCUIT ® -SYNC J l�J A NO— v-AUDIBLE P AUDIBLE C _ NAC DSM#3 P MINUS z CIRCUIT —I I— +IN 2 Ititel 4 STROBE ______pp, STROBE +OUT 2 NAC —C7+SYNC AS a AS q NAC CIRCUIT ® -SYNC J L._ CIRCUIT — RETURN DSM INTERCONNECTING WIRING SHOWN. MAXIUMUM OF TWENTY(20)MODULES - GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-Tel: (203)484-7161 -Fax:(203)484-7118 www.gamewell-fci.com 9020-0572 Rev.Cl page 3 of 4 J • • Architects and Engineers Specifications The notification appliances shall be Cooper-Wheelock Series AS audible/strobe appliances and Series AH audible appliances or approved equals. The Series AS appliance shall be listed under UL Standard 1971 (Emergency Devices for the Hearing Impaired) for indoor Fire Protection Service. The Series AH Audible shall be UL Listed under Standard 464 (Fire Protective Signaling). Both shall meet the requirements of FCC Part 15 Class B. All inputs shall be compatible with standard reverse polarity supervision of circuit wiring by a fire alarm control panel (FACP). The audible portion of the appliance shall have a minimum of three (3) field selectable settings for dBA levels and shall have a choice of continuous or temporal pattern audible output. The strobe portion of the appliance shall produce a flash rate of one (1) flash per second over the Regulated Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged Lexan®lens. The series AS shall be of low current design. Where Multi- Candela appliances are specified, the strobe intensity shall have a minimum of four(4)field selectable settings and shall be rated per UL Standard 1971 at: 15, 30, 75, and 110 candela for wall mount, or 15, 30, 75, and 95 candela for ceiling mount. The selector switch for selecting the candela shall be tamper resistant and not accessible from the front of the appliance. The 15/75 candela strobe shall be specified when 15 cd UL Standard 1971 Listing with 75 cd on-axis is required (e.g. ADA compliance). When synchronization is required, the appliance shall be compatible with Cooper-Wheelock's SM and DSM Sync Modules. The strobes shall not drift out of synchronization at any time during operation. If the sync module fails to operate, i.e. contacts remain closed), the strobe shall revert to a non-synchronized flash-rate. The appliance shall also be designed so that the audible signal may be silenced while maintaining strobe activation. The Series AS audible/strobe and Series AH audible shall incorporate a patented universal mounting plate that shall allow mount- ing on a single-gang, double-gang, 4-inch square, 100 mm European type backbox, or the SHBB surface backbox. If required, an NATP(Notification Appliance Trimplate)shall be provided. All notification appliances shall be backward compatible. Specifications Model Strobe Non-Sync SyncwSM/ 24 12 Wall Ceiling UL MEA CSFM FM BFP Candela or DSM VDC VDC Mount Mount AS-24MCW-FR 15/30/75/110 X X X - X - X X X X X AS-24M CW—FW 15/30/75/110 X X X - X - X X X X X AS-241575W-FR 15(75 on Axis) X X X - X - X X X X X AS-121575W—FR 15(75 on Axis) X X X - X - X X X X X AS-24MCC—FW 15/30/75/95 X X X - - X X * * * ASW-P-2475W—FR 75 @-31° F X X X - X - X X X X * AH—24-R - X X X - X X X X X X X AH—24W P-R - X X X - X X X X AH—12W P-R - X X - X X X X X Ordering Information Part Number Description 9024 AS-24MCW-FR 9025 AS-24M CW—FW 7405 AS-241575W- FR 7410 AS-121575W—FR 3162 AS-24MCC—FW 9012 ASW-P-2475W—FR 7892 AH—24-R 7891 AH—12-R 7416 AH—24W P-R 7415 AH—12W P-R GAMEWELL-FCI 12 Clintonville Road, Northford,CT 06472-Tel:(203)484-7161 -Fax:(203)484-7118 www.gamewell-fci.com 9020-0572 Rev.Cl page 4 of 4 Effective July 2016 Technical Data TD450040EN Supersedes July 2011 Wheelock RSS and RSSP Strobes and Strobe Plates Description • The Wheelock patented RSS Strobe appliances and RSSP Strobe Plates by Eaton have lower current draw while maintaining Foutstanding performance, reliability and cost effectiveness.These R versatile appliances will satisfy virtually all requirements for indoor, wall or ceiling mount applications. Strobe options include the Wheelock Patented MCW multi-candela strobe with field selectable candela settings of 15/3O/75/11Ocd or the high intensity MCWH strobe with field selectable 135/185cd.Ceiling mount models include the patented MCC multi-candela ceiling strobe FIRE with field selectable intensities of 15/3O/75/95cd or the high intensity MCCH strobe with field selectable 115/177cd. All models may be synchronized using the Wheelock DSM Sync Modules,Wheelock Power Supplies or other manufacturers panels incorporating the Wheelock Patented Sync Protocol. Synchronized FIRE strobes can eliminate possible restrictions on the number of strobes in the field of view.Wheelock's synchronized strobes offer an easy way to comply with ADA recommendations concerning photosensitive epilepsy as well as meeting the requirements of NFPA 72. H-- ail, LI The Wheelock Series RSS Strobes employ a Patented Integral Strobe Mounting Plate that can be mounted to a single gang, double gang, 4" square, 1OOmm European backboxes or the SHBB surface backbox. If the flush backbox has side or top space between it and the finished wall,the NATP(Notification Appliance Trimplate) may FIRE be used. It provides an additional .65" of trim for the Appliance.An attractive cover plate is provided for a clean, finished appearance on all models. The RSSP Multi-Candela Strobe Plates are a cost effective way to retrofit required wall strobe appliances to bells, horns, chimes, multitones or speakers and easily mounts to standard 4" backboxes or for surface mount use with the Wheelock SBL2 surface backbox. Er N Powering Business Worldwide Technical Data TD450040EN Wheelock RSS and RSSP Strobes and Strobe Plates Effective July 2016 Features Drawings • Approvals include: UL Standard 1971, NewYork City(MEA), California State Fire Marshal (CSFM), Factory Mutual (FM),and Chicago(BFP)See approvals by model in Specifications and Ordering information • ADA/NFPA/UFC/ANSI compliant. Meets OSHA 29 Part 1910.16 4.75 2.58 • Wall mount Multi-Candela models are available with Field Selectable Candela Settings of 15/30/75/110cd or 135/185cd. • Wall mount Multi-Candela models are available with Field Selectable Candela Settings of 15/30/75/110cd or 135/185cd. • Strobes produce 1 flash per second over the regulated voltage 4.75 range • 12 and 24 VDC models with wide UL"Regulated Voltage" using I 1 filtered(DC)or unfiltered VRMS input voltage • Synchronize using the Wheelock sync modules or panels with built-in Wheelock Patented Sync Protocol • Fast installation with IN/OUT screw terminals using#12 to#18 AWG wire Note:All CAUTIONS and WARNINGS are identified by the symbol A.All warnings are printed in bold capital letters. Figure 1.RSS wall strobe-Front&Side Views A WARNING General Notes PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING,SPECIFYING OR APPLYING • Strobes are designed to flash at 1 flash per second minimum over THIS PRODUCT.VISIT WWW.EATON.COM/MASSNOTIFICATION OR their"Regulated Voltage Range." Note that NFPA-72 specifies a CONTACT EATON FOR THE CURRENT INSTALLATION INSTRUCTIONS. flash rate of 1 to 2 flashes per second and ADA Guidelines specify FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS,CAUTIONS OR a flash rate of 1 to 3 flashes per second. WARNINGS COULD RESULT IN IMPROPER APPLICATION,INSTALLATION • All candela ratings represent minimum effective Strobe intensity AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, based on UL 1971. WHICH COULD RESULT IN PROPERTY DAMAGE,AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. Audibles/Speakers for RSSP Product Series Multitone Appliances AMT,MT Horns AH,NH,HS Motor Bells MB-G6/G10 Speakers ET-1010/1080,E70,ET70 _ Chimes CH70 2 EATON www.eaton.com Wheelock RSS and RSSP Strobes and Strobe Plates Technical Data TD450040EN Effective July 2016 Table 1. Maximum RMS Current UL/ULC MAX CURRENT a RSS/RSSP Strobes 24VDC Regulated Voltage Model Range VDC 1575 15cd 30cd 75cd 95cd 110cd 115cd 135cd 177cd 185cd 121575W 16.0-33.0 0.255 1* 24MCW 16.0-33.0 0.060 0.092 0.165 0.220 24MCWH 16.0-33.0 0.300 0.420 ► 24MCC 16.0-33.0 0.065 0.105 0.189 0.249 24MCCH 16.0-33.0 0.300 0.420 Table 2. Specification &Ordering Information Agency Approvals Non- MountingSquare Model Order# Strobe Candela Red White Wall Ceiling Sync Options or Round UL MEA CSFM FM BFP RSS-24MCW-FR 9400 15/30/75/110 X X X B,D,E,F,G,H,J,N,O,R,X square X X X X X RSS-24MCW-FW 9401 15/30/75/110 X X X B,D,E,F,G,H,J,N,O,R,X square X X X X X RSS-24MCW-AR 9773 15/30/75/110 X X X B,D,E,F,G,H,J,N,O,R,X square X X X X X RSS-121575W-FR 7476 15(75 on Axis) X X X B,D,E,F,G,H,J,N,O,R,X square X X X X X RSS-121575W-FW 7468 15(75 on Axis) X X X B,D,E,F,G,H,J,N,O,R,X square X X X X X RSS-24MCC-FW 3158 15/30/75/95 X X X B,D,E,F,G,H,J,N,O,R,X square X X X X RSS-24MCC-FR 3157 15/30/75/95 X X X B,D,E,F,G,H,J,N,O,R,X square X X X X RSS-24MCCH-FW 3461 115/177 X X X B,D,E,F,G,H,J,N,O,R,X square X X X X RSS-24MCWH-FR 3465 135/185 X X X B,D,E,F,G,H,J,N,O,R,X square X X X X RSS-24MCWH-FW 3464 135/185 X X X B,D,E,F,G,H,J,N,O,R,X square X X X X RSSWP-2475W-FR 9013 180 77F X X X B,D,E,F,G,H,J,NO,R,X square X X X X 75@-31 F RSSWP-2475W-FW 3034 180@ 77 F X X X B,D,E,F,G,H,J,N,O,R,X square X X X X 75©-31 F RSSP-121575W-FR 7798 15(75 on Axis) X X X D,E,Z square X X X X RSSP-24MCW-FR 9402 15/30/75/110 X X X D,E,Z square X X X X X RSSP-24MCWH-FR 9482 135/185 X X X B,D,E,F,G,H,J,N,O,R,X square X X X Table 3. Specifications Physical Material Red or white textured UV stabilized,colored impregnated engineered plastic.Exceeds 94V-0 UL flammability rating. Weight RSS Strobe:0.40 lbs(0.181 kg) Lens GE Lexan 943A Dimensions RSS Strobe: 4.75"W x 4.75"H x 2.58"D Operating Temperature Indoor:33.8°F to 120.2°F(0°C to 49°C)and maximum humidity of 93% Wire Connections #12 through#18 AWG Power&General Operating voltage 25/70 VRMS Strobe Output Rating UL 1971 Strobe Flash Rate Strobes are designed to flash at 1 flash per second Synchronization Models Strobes can be synchronized with Wheelock's DSM Sync Modules,Power Supplies or SAFEPATH products,using Wheelock patented sync protocol a RMS current ratings are per UL maximum RMS method.UL max current rating is the maximum RMS current within the listed voltage range(16-33v for 24v units). For strobes the UL max current is usually at the minimum listed voltage(16v for 24v units). For audibles the max current is usually at the maximum listed voltage(33v for 24v units).For unfiltered FWR ratings,see installation instructions. b For information on mounting options,refer to specification sheet TD450028EN. EATON www.eaton.com 3 Technical Data TD450040EN Wheelock RSS and RSSP Strobes and Strobe Plates Effective July 2016 Architects and Engineers Specifications The visual notification appliances shall be Wheelock RSS Strobe time during operation. If the sync module or Power Supply fails to appliances or approved equals.The Series RSS shall meet and be operate, (i.e., contacts remain closed), the strobe shall revert to a listed for UL Standard 1971 (Emergency Devices for the Hearing- non-synchronized flash rate.The strobes shall be designed for indoor Impaired)for Indoor Fire Protection Service.The strobe shall be listed surface of flush mounting. for indoor use and shall meet the requirements of FCC Part 15 Class B.The strobe appliances shall produce a flash rate of one(1)flash The RSS Strobe appliances shall incorporate a Patented, Integral per second over the Regulated Voltage Range and shall incorporate a Strobe Mounting Plate that shall allow mounting to single gang, Xenon flashtube enclosed in a rugged Lexan®lens.All inputs shall be double-gang,4-inch square, 100mm European type backboxes, compatible with standard reverse polarity supervision of circuit wiring or the SHBB Surface Backbox. If required, an NATP(Notification by a Fire Alarm Control Panel (FACP).When Strobe Plates are to be ApplianceTrimplate)shall be provided.An attaching cover plate shall installed,they shall be the Wheelock Series RSSP Strobe Plate and be provided to give the Appliance and attractive appearance.The shall have the same electronic circuitry as the Wheelock Series RSS. Appliance shall not have any mounting holes or screw heads visible when the installation is completed. The RSS Strobe shall be of low current design.Where Multi- Candela appliances are specified,the strobe intensity shall have The RSSP Multi-Candela or single candela Strobe Plate shall mount field selectable settings and shall be rated per UL Standard 1971 at to either a standard 4 inch square backbox for flush mounting,or the 15/30/75/110cd or 135/185cd for wall mount and 15/30/75/95cd or Wheelock SBL2 backbox for surface mounting. 115/177cd for ceiling mount.The selector switch for selecting the All notification appliances shall be backward compatible. candela shall be tamper resistant. When synchronization is required,the appliance shall be compatible UL, MEA, CSFM, BFP FM with Wheelock's DSM Sync Modules,Wheelock Power Supplies or other manufacturers panels with built-in Wheelock Patented Sync Protocol.The strobes shall not drift out of synchronization at any- Note:Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Wheelock Inc.,dba Eaton standard terms and conditions. Ir Member WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY Eaton 1000 Eaton Boulevard Cleveland,OH 44122 United States Eaton.corn Eaton Life safety&mass notification solutions 273 Branchport Ave. Long Branch,NJ 07740 www.eaton.com/massnotification ©2016 Eaton All Rights Reserved Eaton is a registered trademark. E Printed in USA Publication No.TD450040EN All other trademarks are property Powenng Business Worldwide July 2016 of their respective owners.